AUTHOR=Weißig Dorothea M. , Dobenecker Britta , Zablotski Yury , Lauer Susanne K. TITLE=Repeatability and reliability of kinetic and temporospatial gait parameters measured with a pressure-sensitive treadmill in healthy cats JOURNAL=Frontiers in Veterinary Science VOLUME=Volume 12 - 2025 YEAR=2025 URL=https://www.frontiersin.org/journals/veterinary-science/articles/10.3389/fvets.2025.1707477 DOI=10.3389/fvets.2025.1707477 ISSN=2297-1769 ABSTRACT=ObjectivesInterest in feline kinetic gait variables has increased substantially. This study aimed to assess repeatability and intersession reliability of kinetic gait analysis in healthy cats using a pressure-sensitive treadmill.MethodsHealthy client-owned cats (n = 9) and cats housed at the cattery of the Chair of Animal Nutrition and Dietetics (n = 5), without orthopedic abnormalities based on history, examination, and subjective gait analysis, were enrolled. Cats (mean body weight: 5.2 ± 0.9 kg, age: 4.1 ± 1.7 years) were acclimated to a pressure-sensitive treadmill system (FDM-T-CanidGait®, zebris Medical GmbH, Isny, Germany). Treadmill velocity was adjusted individually for comfortable walking. For data acquisition, cats were placed on the treadmill and repositioned if they jumped off (total duration: 10 min, 5 × 2 min). The first five sequences with six valid gait cycles were selected. Data acquisition was repeated after 2 weeks at the same speed. Average maximal pressure, loaded paw surface, step and stride length, step width, stance and swing phase percentages, hind reach, step-stride ratio, and symmetry indices were calculated. Repeatability was assessed with linear mixed-effects models and intersession reliability with intraclass correlation coefficients (ICCs). Reliability was categorized as excellent, good, moderate, or poor, with statistical significance set at a p-value of < 0.05.ResultsMost parameters did not differ significantly between time points, except for the average maximal pressure of the left hindlimb (p = 0.037) and hind reach of both hindlimbs (p ≤ 0.001). ICCs demonstrated good to excellent reliability (0.885–0.988) for all variables, except for symmetry indices (moderate reliability; forelimbs: 0.547, hindlimbs: 0.676).Conclusion and relevanceA pressure-sensitive treadmill provides repeatable feline gait measurements with good to excellent intersession reliability for most variables and moderate reliability for symmetry indices, offering a reference for future studies. Further studies involving larger cohorts are needed to confirm these results and support broader clinical application.