<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Vet. Sci.</journal-id>
<journal-title>Frontiers in Veterinary Science</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Vet. Sci.</abbrev-journal-title>
<issn pub-type="epub">2297-1769</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fvets.2025.1540413</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Veterinary Science</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Exhaled propofol monitoring for plasma drug prediction in rats</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" equal-contrib="yes">
<name><surname>Li</surname> <given-names>Xiaoxiao</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="author-notes" rid="fn001"><sup>&#x02020;</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/software/"/>
<role content-type="https://credit.niso.org/contributor-roles/validation/"/>
<role content-type="https://credit.niso.org/contributor-roles/visualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author" equal-contrib="yes">
<name><surname>Chang</surname> <given-names>Pan</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="author-notes" rid="fn001"><sup>&#x02020;</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/2910251/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/validation/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Liu</surname> <given-names>Xing</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/data-curation/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Kang</surname> <given-names>Yi</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Zhao</surname> <given-names>Zhongjun</given-names></name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/resources/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Duan</surname> <given-names>Yixiang</given-names></name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name><surname>Zhang</surname> <given-names>Wensheng</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="corresp" rid="c001"><sup>&#x0002A;</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/1287309/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/data-curation/"/>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
</contrib-group>
<aff id="aff1"><sup>1</sup><institution>Department of Anesthesiology, West China Hospital, Sichuan University</institution>, <addr-line>Chengdu</addr-line>, <country>China</country></aff>
<aff id="aff2"><sup>2</sup><institution>Laboratory of Anesthesia and Critical Care Medicine, National-Local Joint Engineering Research Centre of Translational Medicine of Anesthesiology, West China Hospital, Sichuan University</institution>, <addr-line>Chengdu</addr-line>, <country>China</country></aff>
<aff id="aff3"><sup>3</sup><institution>School of Mechanical Engineering, Sichuan University</institution>, <addr-line>Chengdu</addr-line>, <country>China</country></aff>
<author-notes>
<fn fn-type="edited-by"><p>Edited by: Ismael Hern&#x000E1;ndez Avalos, National Autonomous University of Mexico, Mexico</p></fn>
<fn fn-type="edited-by"><p>Reviewed by: Paolo Franci, University of Turin, Italy</p>
<p>Claudia Interlandi, University of Messina, Italy</p></fn>
<corresp id="c001">&#x0002A;Correspondence: Wensheng Zhang <email>zhang_ws&#x00040;scu.edu.cn</email></corresp>
<fn fn-type="equal" id="fn001"><p>&#x02020;These authors have contributed equally to this work</p></fn></author-notes>
<pub-date pub-type="epub">
<day>12</day>
<month>02</month>
<year>2025</year>
</pub-date>
<pub-date pub-type="collection">
<year>2025</year>
</pub-date>
<volume>12</volume>
<elocation-id>1540413</elocation-id>
<history>
<date date-type="received">
<day>05</day>
<month>12</month>
<year>2024</year>
</date>
<date date-type="accepted">
<day>27</day>
<month>01</month>
<year>2025</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x000A9; 2025 Li, Chang, Liu, Kang, Zhao, Duan and Zhang.</copyright-statement>
<copyright-year>2025</copyright-year>
<copyright-holder>Li, Chang, Liu, Kang, Zhao, Duan and Zhang</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license>
</permissions>
<abstract>
<p>While propofol can be detected in exhaled breath in rats, robust evidence supporting its correlation with plasma concentrations or its use in predicting plasma levels remains lacking. In this study, eighteen mechanically ventilated rats were divided into three groups and injected with low (Group BL, <italic>n</italic> = 6), medium (Group BM, <italic>n</italic> = 6), or high (Group BH, <italic>n</italic> = 6) doses of propofol. The propofol concentration in exhaled breath (Ce-pro) was determined online using vacuum ultraviolet time-of-flight mass spectrometry (VUV-TOF MS), while the propofol concentration in plasma (Cp-pro) were measured using high-performance liquid chromatograph. The results indicated that after propofol injection, the peak Ce-pro was 5.87 &#x000B1; 1.67 ppbv, 16.54 &#x000B1; 7.22 ppbv, and 25.40 &#x000B1; 3.68 ppbv, respectively. Across the different dose groups, C<sub>max</sub> of Ce-pro and Cp-pro were linearly correlated (<italic>P</italic><sub>BL</sub> = 0.032, <italic>P</italic><sub>BM</sub> = 0.031, <italic>P</italic><sub>BH</sub> = 0.049). T<sub>max</sub> of Ce-pro was 1.22 &#x000B1; 0.17 min, 1.28 &#x000B1; 0.13 min, and 1.33 &#x000B1; 0.01 min, respectively (<italic>P</italic> = 0.341), similar to the T<sub>max</sub> of Cp-pro (1.00 &#x000B1; 0.00 min). After natural logarithm transformation, the correlation between LN(Ce-pro) and LN(Cp-pro) was well fitted by a linear model, with <inline-formula><mml:math id="M1"><mml:mrow><mml:msubsup><mml:mi>R</mml:mi><mml:mrow><mml:mi>B</mml:mi><mml:mi>L</mml:mi></mml:mrow><mml:mn>2</mml:mn></mml:msubsup></mml:mrow></mml:math></inline-formula> = 0.94, <inline-formula><mml:math id="M2"><mml:mrow><mml:msubsup><mml:mi>R</mml:mi><mml:mrow><mml:mi>B</mml:mi><mml:mi>M</mml:mi></mml:mrow><mml:mn>2</mml:mn></mml:msubsup></mml:mrow></mml:math></inline-formula> = 0.95, <inline-formula><mml:math id="M3"><mml:mrow><mml:msubsup><mml:mi>R</mml:mi><mml:mrow><mml:mi>B</mml:mi><mml:mi>H</mml:mi></mml:mrow><mml:mn>2</mml:mn></mml:msubsup></mml:mrow></mml:math></inline-formula> = 0.98, and <inline-formula><mml:math id="M4"><mml:mrow><mml:msubsup><mml:mi>R</mml:mi><mml:mrow><mml:mi>A</mml:mi><mml:mi>L</mml:mi><mml:mi>L</mml:mi></mml:mrow><mml:mn>2</mml:mn></mml:msubsup></mml:mrow></mml:math></inline-formula> = 0.96. Using the obtained regression equation LN(Cp-pro) = 1.42<sup>&#x0002A;</sup>LN(Ce-pro)-1.70, the predicted Cp-pro values showed excellent agreement with the actual values within groups (ICC<sub>BL</sub> = 0.92; ICC<sub>BM</sub> = 0.97, ICC<sub>BH</sub> = 0.99, all <italic>P</italic> &#x0003C; 0.001). This study demonstrates a strong correlation between exhaled and plasma propofol concentrations in rats, indicating that exhaled concentrations can be effectively used to estimate plasma levels.</p></abstract>
<kwd-group>
<kwd>propofol</kwd>
<kwd>rat</kwd>
<kwd>exhaled breath</kwd>
<kwd>pharmacokinetics</kwd>
<kwd>VUV-TOF MS</kwd>
</kwd-group>
<contract-sponsor id="cn001">Sichuan Provincial Science and Technology Support Program<named-content content-type="fundref-id">https://doi.org/10.13039/100012542</named-content></contract-sponsor>
<counts>
<fig-count count="5"/>
<table-count count="1"/>
<equation-count count="0"/>
<ref-count count="40"/>
<page-count count="9"/>
<word-count count="5877"/>
</counts>
<custom-meta-wrap>
<custom-meta>
<meta-name>section-at-acceptance</meta-name>
<meta-value>Anesthesiology and Animal Pain Management</meta-value>
</custom-meta>
</custom-meta-wrap>
</article-meta>
</front>
<body>
<sec sec-type="intro" id="s1">
<title>Introduction</title>
<p>Propofol, a widely used intravenous anesthetic in animal anesthesia, is favored for its rapid onset and effective anesthetic properties (<xref ref-type="bibr" rid="B1">1</xref>, <xref ref-type="bibr" rid="B2">2</xref>). Frequent blood sampling during pharmacokinetic (PK) analysis in rats poses significant challenges for operators, requiring a high level of technical proficiency. Improper techniques can lead to blood contamination or sampling failure, particularly in small animals. Additionally, due to limitations in analytical methods, monitoring propofol concentrations in plasma (Cp-pro) online remains challenging. Previous studies have shown that propofol can be detected in exhaled breath. Instruments such as selected ion flow tube mass spectrometry (SIFT-MS) (<xref ref-type="bibr" rid="B3">3</xref>), ion molecule reaction mass spectrometry (IMR-MS) (<xref ref-type="bibr" rid="B4">4</xref>), ion mobility spectrometry (IMS) (<xref ref-type="bibr" rid="B5">5</xref>), and gas chromatography combined with surface acoustic sensor (GC-SAW) (<xref ref-type="bibr" rid="B6">6</xref>) have been explored for exhaled propofol concentration (Ce-pro) monitoring. However, these instruments are often characterized by their large size and high noise levels. Furthermore, robust evidence supporting its correlation with plasma concentrations or its use in predicting plasma levels remains lacking.</p>
<p>Our team developed a mobile exhaled propofol concentration monitor utilizing vacuum ultraviolet (VUV) technology combined with time-of-flight mass spectrometry (TOF MS) (<xref ref-type="bibr" rid="B7">7</xref>, <xref ref-type="bibr" rid="B8">8</xref>). This instrument has demonstrated its capability for online monitoring of propofol in rats, beagles, and humans. In this study, rats were administered single intravenous injections of different doses of propofol. The Ce-pro was monitored online using VUV-TOF MS, while the Cp-pro were measured using high-performance liquid chromatograph (HPLC). The aim of this study was to evaluate the consistency between Ce-pro and Cp-pro, and to predict the Cp-pro based on monitored Ce-pro values, providing foundational animal data to support future clinical studies.</p>
</sec>
<sec sec-type="materials and methods" id="s2">
<title>Materials and methods</title>
<sec>
<title>Ethics approval</title>
<p>Eighteen male Sprague-Dawley rats (aged 12&#x02013;15 weeks and weighing 350 &#x000B1; 50 g) obtained from Chengdu DOSSY Experimental Animals Co., Ltd were included in this experiment. All rats were housed in the SPF animal facility at Tianfu Life Science Park, West China Hospital, Sichuan University, with free access to food and water. The experiments began after a one-week acclimatization period. This study was approved by the Animal Ethics Committee of West China Hospital, Sichuan University (20220420001), and all procedures complied with animal welfare guidelines.</p>
</sec>
<sec>
<title>Rat ventilation model</title>
<p>All rats fasted for 12 h before the experiment, with unrestricted access to water. Anesthesia was induced via intraperitoneal injection of 10% Nembutal (pentobarbital sodium, Think-Far Technology, Beijing, China) at 35 mg/kg. Once the righting reflex disappeared, the rats were positioned supine on a heated plate, and their tail veins were punctured and catheterized. A tracheotomy was performed for mechanical ventilation (R407, RWD Life Technology, Shenzhen, China), with the trachea and tracheal catheter firmly secured to prevent air leakage. Ventilator parameters included pure oxygen supply, a respiratory rate of 60 breaths/min, a tidal volume of 1.5 mL/100 g body weight, and an inhalation-to-exhalation ratio of 1:1. One femoral artery was catheterized for blood pressure monitoring (BL-420 F, Chengdu Techman, Chengdu, China), and another for blood sample collection. The rats&#x00027; rectal temperature was measured using a probe (BeneView T8, Shenzhen Mindray, Shenzhen, China), and body temperature was kept at 36.5 &#x000B1; 0.5&#x000B0;C. The heating plate temperature was adjusted if the temperature of rats exceeded 37&#x000B0;C or fell below 36&#x000B0;C. Pentobarbital sodium was re-administered intraperitoneally at one-third of the initial dose every 30 min to maintain anesthesia. Additionally, 0.9 % saline was continuously infused at a rate of 8 mL/kg/h.</p>
</sec>
<sec>
<title>Administration method and dosage</title>
<p>The sample size was determined based on the &#x0201C;Guiding Principles for Registration Review of Animal Testing in Medical Device Studies&#x0201D; issued in China (<xref ref-type="bibr" rid="B9">9</xref>), along with the requirements of pharmacological experiments. Accordingly, each group consisted of six rats. A total of eighteen rats were randomly divided into three groups using a random number table: low-dose (Group BL, <italic>n</italic> = 6), medium-dose (Group BM, <italic>n</italic> = 6), and high-dose (Group BH, <italic>n</italic> = 6) propofol bolus groups. The propofol doses were 1 ED<sub>50</sub> (6 mg/kg, the dose required to abolish the righting reflex in 50% of the rats) for Group BL, 2 ED<sub>50</sub> (12 mg/kg) for Group BM, and 4 ED<sub>50</sub> (24 mg/kg) for Group BH (<xref ref-type="bibr" rid="B10">10</xref>). Propofol across all three groups was administered at a constant rate of 0.4 mL per 30 s using a microinfusion pump (R462, RWD Life Science, Shenzhen, China).</p>
</sec>
<sec>
<title>Ce-pro monitoring</title>
<p>The structure, operating principles, and calibration method of the VUV-TOF MS system have been detailed in our previous study (<xref ref-type="bibr" rid="B11">11</xref>). As shown in <xref ref-type="fig" rid="F1">Figure 1</xref>, a polyurethane tracheal catheter was connected to the VUV-TOF MS instrument via a polycarbonate three-way valve within a respiratory circuit made of polytetrafluoroethylene. Detection conditions were set as previously described, enabling continuous monitoring of propofol at 20-s intervals from the start of administration to 120 min post-administration. An m/z value of 177.6 was identified, and the concentration of propofol in exhaled air was calculated using the calibration curve.</p>
<fig id="F1" position="float">
<label>Figure 1</label>
<caption><p>Schematic diagram of VUV-TOF MS for monitoring the exhaled propofol concentration in rats.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fvets-12-1540413-g0001.tif"/>
</fig>
</sec>
<sec>
<title>Cp-pro monitoring</title>
<p>During the experiment, 0.2 mL of femoral artery blood was collected into EP tubes at specific time points: before propofol administration and at 1, 3, 5, 10, 20, 30, 60, 90, and 120 min post-administration. After each sampling, an equal volume of stored blood (0.2 mL) was reinjected intravenously via the tail vein. Once all samples from a rat were collected, the blood samples were centrifuged at 3,500 rpm for 10 min at 4&#x000B0;C. The supernatant (100 &#x003BC;L) was then extracted and stored at &#x02212;80&#x000B0;C. The Cp-pro was determined using a HPLC system (Waters, Waters Corporation, USA).</p>
<p>The chromatographic conditions were as follows: a Swell Chromplus C18 column (150 mm &#x000D7; 4.6 mm, 5 &#x003BC;m) was used, with the column temperature maintained at 30&#x000B0;C. The mobile phase consisted of pure water and acetonitrile mixed in a 38:62 (v/v) ratio. Fluorescence detection was performed at an excitation wavelength of 276 nm and an emission wavelength of 310 nm. The flow rate was kept constant at 1.0 mL/min, and the injection volume was 10 &#x003BC;L. Retention times were determined to be 3.9 min for thymol (used as the internal standard) and 7.4 min for propofol.</p>
</sec>
<sec>
<title>Statistical analysis</title>
<p>Statistical analyses were conducted using GraphPad Prism (Version 9.4, GraphPad Software, USA). Data are expressed as mean &#x000B1; standard deviation or median (interquartile range). One-way analysis of variance was used for comparisons among three groups. Spearman correlation analysis was performed to evaluate the relationship between Ce-pro and Cp-pro, with the correlation coefficient (<italic>r</italic>) calculated. Furthermore, the natural logarithms (LN) of Ce-pro and Cp-pro were calculated, followed by a linear correlation analysis to determine the <italic>R</italic><sup>2</sup>. The intraclass correlation coefficient (ICC) was calculated to assess the correlation of predicted Cp-pro based on the regression model from all groups and the actual Cp-pro values. The PK model and parameters were calculated using Phoenix WinNonlin software (Phoenix WinNonlin, Certara, USA). Concentrations below the limit of detection (LOD) were treated as 0 before reaching C<sub>max</sub> and as not detectable after reaching C<sub>max</sub>. A two-step approach was employed to estimate the PK parameters. Individual data were fitted to one-compartment, two-compartment, and three-compartment models. Model parameters were estimated using the least-squares method. Comparisons between Ce-pro and Cp-pro for T<sub>1/2</sub>, T<sub>1/2</sub>, K<sub>10</sub>, K<sub>12</sub>, and K<sub>21</sub> were performed using the <italic>t</italic>-test. However, no comparisons were made for V<sub>1</sub>, CL, and AUC<sub>0 &#x02212; 120</sub>. A <italic>P</italic> &#x0003C; 0.05 was considered statistically significant.</p>
</sec>
</sec>
<sec sec-type="results" id="s3">
<title>Results</title>
<p>A total of 18 male rats from the same batch were included in this experiment, with mean body weights of 344 &#x000B1; 21 g in Group BL, 330 &#x000B1; 32 g in Group BM, and 318 &#x000B1; 19 g in Group BH (<italic>P</italic> = 0.218). The administered doses were 2.07 &#x000B1; 0.13 mg in Group BL, 4.76 &#x000B1; 0.39 mg in Group BM, and 7.63 &#x000B1; 0.46 mg in Group BH.</p>
<sec>
<title>Validation of the determination method of Ce-pro</title>
<p>As shown in <xref ref-type="fig" rid="F2">Figure 2</xref>, the m/z of propofol detected by the VUV-TOF MS was 177.6. For measured concentrations ranging from 0.04 ppbv to 55.68 ppbv, the correlation between signal intensity and concentration followed a second-order polynomial distribution. The calibration curve was fitted to the equation y = &#x02212;2,794 &#x0002B; 24,481<sup>&#x0002A;</sup>x &#x0002B; 1,427<sup>&#x0002A;</sup>x<sup>2</sup> (<italic>R</italic><sup>2</sup> = 0.9995). The LOD was 0.04 ppbv, and the limit of quantification (LOQ) was 0.12 ppbv, respectively.</p>
<fig id="F2" position="float">
<label>Figure 2</label>
<caption><p>The mass-to-charge ratio and calibration curve of propofol based on VUV-TOF MS. m/z: Mass-to-charge ratio; <bold>(A)</bold> shows the m/z of propofol in the VUV-TOF MS, and <bold>(B)</bold> presents its calibration curve, following a second-order polynomial distribution.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fvets-12-1540413-g0002.tif"/>
</fig>
</sec>
<sec>
<title>The PK models and parameters of Ce-pro and Cp-pro</title>
<p>As shown in <xref ref-type="fig" rid="F3">Figure 3</xref>, the average C<sub>max</sub> of Ce-pro in the three groups was 5.87 &#x000B1; 1.67 ppbv, 16.54 &#x000B1; 7.22 ppbv, and 25.40 &#x000B1; 3.68 ppbv, respectively, while the average C<sub>max</sub> of Cp-pro was 5.71 &#x000B1; 0.94 &#x003BC;g/mL, 13.71 &#x000B1; 6.53 &#x003BC;g/mL, and 32.59 &#x000B1; 7.17 &#x003BC;g/mL, respectively. Across the different dose groups, the C<sub>max</sub> of Ce-pro and Cp-pro showed a linear correlation (<italic>P</italic><sub>BL</sub> = 0.032, <italic>P</italic><sub>BM</sub> = 0.031, <italic>P</italic><sub>BH</sub> = 0.049). The T<sub>max</sub> of Ce-pro was 1.22 &#x000B1; 0.17 min, 1.28 &#x000B1; 0.13 min, and 1.33 &#x000B1; 0.01 min, respectively (<italic>P</italic> = 0.341), which was similar to the T<sub>max</sub> of Cp-pro (1.00 &#x000B1; 0.00 min). As shown in <xref ref-type="table" rid="T1">Table 1</xref>, the Ce-pro and Cp-pro data were well described by the two-compartment model. No significant differences were observed between the Ce-pro and Cp-pro groups for the T<sub>1/2&#x003B1;</sub>, K<sub>12</sub>, and K<sub>21</sub> parameters. However, the K<sub>10</sub> values in Ce-pro were significantly lower than those in Cp-pro (<italic>P</italic><sub>BL</sub> &#x0003C; 0.001, <italic>P</italic><sub>BM</sub> = 0.045, <italic>P</italic><sub>BH</sub> = 0.006).</p>
<fig id="F3" position="float">
<label>Figure 3</label>
<caption><p>Time-concentration curves of propofol in exhaled breath and plasma. <bold>(A)</bold> displays the time-concentration curves of propofol in exhaled breath at different doses, while <bold>(B)</bold> shows the corresponding curves in plasma. Ce-pro, Propofol concentration in exhaled breath; ppbv, Parts per billion by volume; Cp-pro, Propofol concentration in plasma; Group BL, Low-dose bolus injection; Group BM, Medium-dose bolus injection; Group BH, High-dose bolus injection.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fvets-12-1540413-g0003.tif"/>
</fig>
<table-wrap position="float" id="T1">
<label>Table 1</label>
<caption><p>The PK parameters of Ce-pro and Cp-pro.</p></caption>
<table frame="box" rules="all">
<thead>
<tr style="background-color:#919498;color:#ffffff">
<th/>
<th valign="top" align="center" colspan="3"><bold>Group BL (</bold><italic><bold>n</bold></italic> = <bold>6)</bold></th>
<th valign="top" align="center" colspan="3"><bold>Group BM (</bold><italic><bold>n</bold></italic> = <bold>6)</bold></th>
<th valign="top" align="center" colspan="3"><bold>Group BH (</bold><italic><bold>n</bold></italic> = <bold>6)</bold></th>
</tr>
</thead>
<tbody>
<tr style="background-color:#919498;color:#ffffff">
<td valign="top" align="left"><bold>Parameter</bold></td>
<td valign="top" align="center"><bold>Ce-pro</bold></td>
<td valign="top" align="center"><bold>Cp-pro</bold></td>
<td valign="top" align="center"><italic><bold>P</bold></italic></td>
<td valign="top" align="center"><bold>Ce-pro</bold></td>
<td valign="top" align="center"><bold>Cp-pro</bold></td>
<td valign="top" align="center"><italic><bold>P</bold></italic></td>
<td valign="top" align="center"><bold>Ce-pro</bold></td>
<td valign="top" align="center"><bold>Cp-pro</bold></td>
<td valign="top" align="center"><italic><bold>P</bold></italic></td>
</tr>
<tr>
<td valign="top" align="left">V<sub>1</sub>, mg/(conc_unit)</td>
<td valign="top" align="center">0.29 (0.09)</td>
<td valign="top" align="center">0.25 (0.05)</td>
<td valign="top" align="center">/</td>
<td valign="top" align="center">0.22 (0.12)</td>
<td valign="top" align="center">0.21 (0.10)</td>
<td valign="top" align="center">/</td>
<td valign="top" align="center">0.24 (0.05)</td>
<td valign="top" align="center">0.19 (0.04)</td>
<td valign="top" align="center">/</td>
</tr>
<tr>
<td valign="top" align="left">CL, mg/(min<sup>&#x0002A;</sup>conc_unit)</td>
<td valign="top" align="center">0.02 (0.01)</td>
<td valign="top" align="center">0.06 (0.01)</td>
<td valign="top" align="center">/</td>
<td valign="top" align="center">0.02 (0.01)</td>
<td valign="top" align="center">0.04 (0.01)</td>
<td valign="top" align="center">/</td>
<td valign="top" align="center">0.03 (0.01)</td>
<td valign="top" align="center">0.03 (0.01)</td>
<td valign="top" align="center">/</td>
</tr>
<tr>
<td valign="top" align="left">AUC<sub>0 &#x02212; 120</sub>, min<sup>&#x0002A;</sup>conc_unit</td>
<td valign="top" align="center">108.14 (30.44)</td>
<td valign="top" align="center">38.08 (6.92)</td>
<td valign="top" align="center">/</td>
<td valign="top" align="center">194.48 (34.72)</td>
<td valign="top" align="center">95.19 (12.91)</td>
<td valign="top" align="center">/</td>
<td valign="top" align="center">289.10 (37.97)</td>
<td valign="top" align="center">229.27 (42.13)</td>
<td valign="top" align="center">/</td>
</tr>
<tr>
<td valign="top" align="left">T<sub>1/2&#x003B1;</sub>, min</td>
<td valign="top" align="center">3.06 (1.31)</td>
<td valign="top" align="center">1.81 (0.49)</td>
<td valign="top" align="center">0.058</td>
<td valign="top" align="center">2.31 (0.70)</td>
<td valign="top" align="center">2.11 (0.83)</td>
<td valign="top" align="center">0.685</td>
<td valign="top" align="center">2.54 (1.06)</td>
<td valign="top" align="center">2.04 (0.41)</td>
<td valign="top" align="center">0.307</td>
</tr>
<tr>
<td valign="top" align="left">T<sub>1/2&#x003B2;</sub>, min</td>
<td valign="top" align="center">74.92 (29.66)</td>
<td valign="top" align="center">29.57 (10.96)</td>
<td valign="top" align="center">0.007</td>
<td valign="top" align="center">40.67 (10.88)</td>
<td valign="top" align="center">46.13 (37.51)</td>
<td valign="top" align="center">0.739</td>
<td valign="top" align="center">25.83 (12.74)</td>
<td valign="top" align="center">34.66 (23.15)</td>
<td valign="top" align="center">0.432</td>
</tr>
<tr>
<td valign="top" align="left">K<sub>10</sub>, 1/min</td>
<td valign="top" align="center">0.08 (0.04)</td>
<td valign="top" align="center">0.23 (0.05)</td>
<td valign="top" align="center">&#x0003C; 0.001</td>
<td valign="top" align="center">0.12 (0.05)</td>
<td valign="top" align="center">0.25 (0.14)</td>
<td valign="top" align="center">0.045</td>
<td valign="top" align="center">0.11 (0.02)</td>
<td valign="top" align="center">0.19 (0.05)</td>
<td valign="top" align="center">0.006</td>
</tr>
<tr>
<td valign="top" align="left">K<sub>12</sub>, 1/min</td>
<td valign="top" align="center">0.16 (0.06)</td>
<td valign="top" align="center">0.16 (0.05)</td>
<td valign="top" align="center">0.946</td>
<td valign="top" align="center">0.18 (0.07)</td>
<td valign="top" align="center">0.13 (0.07)</td>
<td valign="top" align="center">0.312</td>
<td valign="top" align="center">0.14 (0.07)</td>
<td valign="top" align="center">0.12 (0.04)</td>
<td valign="top" align="center">0.599</td>
</tr>
<tr>
<td valign="top" align="left">K<sub>21</sub>, 1/min</td>
<td valign="top" align="center">0.04 (0.01)</td>
<td valign="top" align="center">0.05 (0.02)</td>
<td valign="top" align="center">0.252</td>
<td valign="top" align="center">0.05 (0.01)</td>
<td valign="top" align="center">0.03 (0.02)</td>
<td valign="top" align="center">0.084</td>
<td valign="top" align="center">0.10 (0.07)</td>
<td valign="top" align="center">0.08 (0.08)</td>
<td valign="top" align="center">0.542</td>
</tr></tbody>
</table>
<table-wrap-foot>
<p>Data are expressed as the mean (SD). Group BL, bolus injection of low dose; Group BM, bolus injection of medium dose; Group BH, bolus injection of high dose. Ce-pro: propofol concentration in exhaled breath; Cp-pro, propofol concentration in plasma; &#x0201C;conc_unit&#x0201D; in Ce-pro represented ppbv, while in Cp-pro represented &#x003BC;g/mL; V<sub>1</sub>, the apparent volume of the central compartment; CL, total body clearance; AUC<sub>0 &#x02212; 120</sub>, area under the curve of the propofol concentration in exhaled breath or blood vs. time; T<sub>1/2&#x003B1;</sub>, the half-life of distribution; T<sub>1/2&#x003B2;</sub>, the half-life of elimination; K<sub>10</sub>, the rate constant describing elimination from the central compartment to outside; K<sub>12</sub>, the rate constant describing distribution from the central compartment into peripheral compartment; K<sub>21</sub>, the rate constant describing redistribution from the peripheral compartment into the central compartment. For parameters T<sub>1/2&#x003B1;</sub>, T<sub>1/2&#x003B2;</sub>, K<sub>10</sub>, K<sub>12</sub> and K<sub>21</sub>, comparisons between C<sub>E</sub> and C<sub>p</sub> were conducted with a <italic>t</italic> test. For the V<sub>1</sub>, CL, and AUC<sub>0 &#x02212; 120</sub> parameters, no comparisons were performed.</p>
</table-wrap-foot>
</table-wrap>
</sec>
<sec>
<title>Correlation between the Ce-pro and Cp-pro</title>
<p>The results demonstrated a strong correlation between Ce-pro and Cp-pro, with Spearman <italic>r</italic><sub>BL</sub> = 0.98, <italic>r</italic><sub>BM</sub> = 0.98, <italic>r</italic><sub>BH</sub> = 0.99, and <italic>r</italic><sub>ALL</sub> = 0.98, all <italic>P</italic> &#x0003C; 0.001. As illustrated in <xref ref-type="fig" rid="F4">Figure 4</xref>, after applying the LN transformation to Ce-pro (pptv) and Cp-pro (ng/mL) values, the linear relationship between LN(Ce-pro) and LN(Cp-pro) was well described, with <inline-formula><mml:math id="M5"><mml:msubsup><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mtext>BL</mml:mtext></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msubsup></mml:math></inline-formula> = 0.94, <inline-formula><mml:math id="M6"><mml:msubsup><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mtext>BM</mml:mtext></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msubsup></mml:math></inline-formula> = 0.95, <inline-formula><mml:math id="M7"><mml:msubsup><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mtext>BH</mml:mtext></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msubsup></mml:math></inline-formula> = 0.98, and <inline-formula><mml:math id="M8"><mml:msubsup><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mtext>ALL</mml:mtext></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msubsup></mml:math></inline-formula> = 0.96, all <italic>P</italic> &#x0003C; 0.001. Furthermore, based on the obtained overall regression equation LN(Cp-pro) = 1.42<sup>&#x0002A;</sup>LN(Ce-pro)-1.70, the monitored Ce-pro were used to predict Cp-pro. As illustrated in <xref ref-type="fig" rid="F5">Figure 5</xref>, the intraclass correlation coefficients (ICC) indicated excellent agreement between predicted and actual values within groups (ICC<sub>BL</sub> = 0.92; ICC<sub>BM</sub> = 0.97, ICC<sub>BH</sub> = 0.99, all <italic>P</italic> &#x0003C; 0.001.)</p>
<fig id="F4" position="float">
<label>Figure 4</label>
<caption><p>Linear regression models of propofol in exhaled breath and plasma. <bold>(A&#x02013;D)</bold> display the linear regression models of propofol in exhaled breath and plasma for low, medium, high, and combined dosages, respectively. LN(Ce-pro), Natural logarithm of propofol concentration in exhaled breath; LN(Cp-pro), Natural logarithm of propofol concentration in plasma; Group BL, Low-dose bolus injection; Group BM, Medium-dose bolus injection; Group BH, High-dose bolus injection.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fvets-12-1540413-g0004.tif"/>
</fig>
<fig id="F5" position="float">
<label>Figure 5</label>
<caption><p>Consistency of predicted plasma propofol levels Based on exhaled breath measurements. <bold>(A&#x02013;C)</bold> show the actual and predicted plasma propofol concentrations for low, medium, and high doses. Actual (Cp-pro), Measured plasma concentration; Predict (Cp-pro), Predicted plasma concentration. <bold>(D)</bold> presents the Bland-Altman plot, with points evenly distributed around the midline, indicating good consistency. Group BL, Low-dose bolus injection; Group BM, Medium-dose bolus injection; Group BH, High-dose bolus injection.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fvets-12-1540413-g0005.tif"/>
</fig>
</sec>
</sec>
<sec sec-type="discussion" id="s4">
<title>Discussion</title>
<p>This experiment successfully detected the exhaled propofol concentration of rats in real time using the VUV-TOF MS system and obtained estimated PK parameters. Furthermore, a strong correlation was established between exhaled and plasma propofol concentrations, providing a technical basis and animal data for online monitoring of the propofol concentration in future clinical studies.</p>
<p>Individualized dose adjustment based on therapeutic drug monitoring is a critical foundation of precision medicine (<xref ref-type="bibr" rid="B12">12</xref>). The MAC of inhalational anesthetics can be measured online using infrared sensors that detect their specific absorption wavelengths (<xref ref-type="bibr" rid="B13">13</xref>, <xref ref-type="bibr" rid="B14">14</xref>). However, no suitable instruments are currently available for monitoring the concentration of intravenous anesthetics. The traditional GC-MS method is time consuming, which makes it impossible to achieve real-time detection to meet the needs of clinical anesthesia or point-of-care testing (<xref ref-type="bibr" rid="B15">15</xref>). The bispectral index, which reflects the cerebral effects of propofol, can also be unreliable because it can be easily affected by multiple factors, such as the application of an external cardiac pacemaker (<xref ref-type="bibr" rid="B16">16</xref>), changes in body position (<xref ref-type="bibr" rid="B17">17</xref>, <xref ref-type="bibr" rid="B18">18</xref>), or the combination of other drugs, such as ketamine (<xref ref-type="bibr" rid="B19">19</xref>). In 2003, Harrison and his colleagues first discovered that propofol can be measured in exhaled breath by proton transfer reaction-mass spectrometry (PTR-MS) at the ppbv level (<xref ref-type="bibr" rid="B20">20</xref>). This finding led anesthesiologists to recognize propofol as a semivolatile organic compound, prompting studies on its concentration in exhaled breath (<xref ref-type="bibr" rid="B21">21</xref>). However, compared with sevoflurane (156.9 mmHg at 20&#x000B0;C) or water (17.5 mmHg at 20&#x000B0;C), propofol exhibits relatively low volatility due to its low saturated vapor pressure (0.142 mmHg at 20&#x000B0;C) (<xref ref-type="bibr" rid="B22">22</xref>&#x02013;<xref ref-type="bibr" rid="B24">24</xref>). Our team developed a compact MS with high sensitivity of up to pptv level. Compared with the GC-MS analytical method, this system does not require preseparation of air samples, and it achieves a signal response within 1 s. In our study, a measurement period of 20 s was used to avoid intensity errors caused by sudden ventilation changes, thereby improving the stability of the output results. Compared to other online analytical instruments, such as PTR-MS and SIFT-MS, this VUV-TOF-MS instrument features a straightforward and intuitive operation, making it easier for anesthesiologists to use. Although the calibration curve of signal intensity vs. concentration (0.04 ppbv&#x02212;55.68 ppbv) is nonlinear, it follows a second-order polynomial distribution with a high fitting degree (<italic>R</italic><sup>2</sup> = 0.9995). Additionally, the calibration results were robust, with intraday variability &#x0003C; 15 %, meeting the requirements of sample analysis. Berchtold et al. emphasized that sensitivity, selectivity, scan speed, and robustness are critical factors for real-time monitoring of exhaled drugs, all of which are satisfactorily fulfilled by the method of VUV-TOFMS detection (<xref ref-type="bibr" rid="B25">25</xref>). The nonlinear standard curve is attributed to the saturated adsorption of propofol molecules on the instrument pipeline. The proportion of adsorption is high at low concentrations but decreases at high concentrations, resulting in an upward-opening calibration curve (<xref ref-type="bibr" rid="B26">26</xref>).</p>
<p>Compared with other reported results, the correlations between Ce-pro and Cp-pro range from moderate to strong (<italic>R</italic><sup>2</sup> = 0.58&#x02013;0.98) (<xref ref-type="bibr" rid="B6">6</xref>, <xref ref-type="bibr" rid="B27">27</xref>&#x02013;<xref ref-type="bibr" rid="B29">29</xref>), in our study, the correlations were significantly stronger. One possible explanation is the use of a highly sensitive analytical instrument, the VUV-TOF MS, which has a much lower LOD of 0.04 ppbv compared to Multi-Capillary Column Ion Mobility Spectrometry (MCC-IMS), which has an LOD of 0.1 ppbv (<xref ref-type="bibr" rid="B30">30</xref>). Another factor is the use of a heated polyether ether ketone (PEEK) tube (outer diameter: 2.5 mm, inner diameter: 2 mm, length: 150 mm), which was insulated with thermal foam and connected to a temperature control switch to maintain a constant temperature of 100&#x000B0;C. This tube delivered gas samples under negative pressure into the ionization chamber. The PEEK material&#x00027;s high melting point, excellent thermal stability, and strong chemical resistance minimized the adsorption of propofol, thereby preserving sample integrity. Maurer et al. investigated the adsorption and desorption behaviors of various tubing materials with respect to propofol, including perfluoroalkoxy (PFA), polytetrafluoroethylene (PTFE), polyurethane (PUR), silicone, and Tygon (<xref ref-type="bibr" rid="B31">31</xref>). Their findings identified PFA as the most suitable material for measuring the propofol concentration in exhaled breath. However, our preliminary tests demonstrated that PEEK tubing exhibited even lower propofol adsorption compared to PFA. In contrast, the unheated and relatively long PTFE sampling tubes commonly used with MCC-IMS in ventilator setups were found to increase the likelihood of propofol gas loss (<xref ref-type="bibr" rid="B32">32</xref>). Finally, the sampling rate also contributed to the improved results. To minimize the effects of sudden airflow changes on concentration measurements, we used a 20-s sampling interval instead of a 1-s interval. This approach provided a mean concentration value calculated about 20 measurements, significantly enhancing the accuracy compared to single-measurement analysis.</p>
<p>We explored the PK models and parameters of the propofol concentration in exhaled breath following bolus injections at varying doses. The low dose corresponded to the ED<sub>50</sub> for the loss of the righting reflex in rats, while the medium and high doses represented 2ED<sub>50</sub> and 4ED<sub>50</sub> doses, respectively. The exhaled propofol concentration peaked at &#x0007E;1 min after injection and then rapidly decreased, conforming to a two-compartment model. This finding is consistent with results reported in human studies (<xref ref-type="bibr" rid="B4">4</xref>, <xref ref-type="bibr" rid="B6">6</xref>, <xref ref-type="bibr" rid="B33">33</xref>). This is because the lung is one of the central compartments where propofol is distributed rapidly after injection. As propofol-laden blood flows through the alveoli, free and dissolved propofol volatilizes, forming vapor molecules that quickly cross the pulmonary respiratory membrane, facilitating distribution from blood vessels to the alveoli. Although the airway may participate in gas exchange, propofol, a lipophilic, hydrophobic drug with high solubility in blood, is generally believed to be the main site of propofol gas exchange (<xref ref-type="bibr" rid="B34">34</xref>, <xref ref-type="bibr" rid="B35">35</xref>), where the capillary network is abundant, the absorption surface area of the alveoli is large, and the distance between the capillary and alveoli is very small, which is conducive to the exchange of gaseous propofol gas by diffusion (<xref ref-type="bibr" rid="B36">36</xref>). When the concentration of propofol in the alveoli is greater, the transpulmonary gradient is greater, and the driving pressure of propofol through the pulmonary respiratory membrane is greater. Moreover, propofol molecules in exhaled breath can be detected at the following measurement time point with no delay, indicating that the diffusion process was rapid. Some studies have shown that the presence of propofol in breath is detected later than that in blood. Our results suggest that the delay may be due to species differences or detection technology (<xref ref-type="bibr" rid="B37">37</xref>). Compared with the estimated PK parameters of the plasma propofol concentration, the K<sub>10</sub> values in exhaled breath were significantly lower, possibly because of the lower elimination rate of propofol in the lung than in the plasma.</p>
<p>We further analyzed the correlation between propofol concentrations in exhaled breath and plasma, which previous studies have demonstrated to be linearly dependent (<xref ref-type="bibr" rid="B38">38</xref>). Our study also exhibited a strong correlation, with even better consistency compared to previous findings. This improvement can be attributed not only to the superior detection performance of the VUV-TOF MS instrument but also to the meticulous attention we paid during sample collection. A stable and consistent tidal volume is a prerequisite for online monitoring of exhaled propofol concentrations in rats. To achieve this, we performed tracheal intubation with mechanical ventilation to prevent the effects of respiratory depression on concentration measurements caused by excessive propofol. Additionally, the tracheal cannula was secured with ligatures, as closed cuffs are unavailable for rat endotracheal tubes, and ligation effectively reduces the risk of air leakage. Although we collected mixed expiratory breath from the rats instead of alveolar air, we took care to avoid significant positional changes during the procedure to minimize potential variations in alveolar dead space. Additionally, Oluwasola Lawal suggested that the ideal breathing sampling method for exhaled propofol concentration monitoring should be simple and suitable for individual physiology. Mixed expiratory breath is considered the simplest and most accessible type of breath sample (<xref ref-type="bibr" rid="B39">39</xref>). Furthermore, the primary purpose of monitoring exhaled drug concentrations is to accurately reflect plasma drug concentrations. Using the regression equation derived from exhaled and plasma drug concentrations at 1&#x02013;4 times the ED<sub>50</sub> dose, we successfully predicted plasma concentrations corresponding to various exhaled concentrations. The values of ICCs demonstrated excellent agreement between the predicted and measured values, further enhancing the practical significance of monitoring exhaled drug concentrations.</p>
<p>Our study also has some limitations. First, although we tried to explain the pharmacokinetics of the exhaled propofol concentration, the lung physiology is complex, and there are many factors, such as age, sex, tidal volume, respiratory frequency, respiratory mechanics, pulmonary diffusion and functional residual capacity, related to disease status that increase the complexity of the pharmacokinetics of exhaled propofol. Theoretically, it is speculated that the factors affecting lung ventilation and air exchange as well as the factors affecting the ratio of lung ventilation to blood flow can have a certain effect (<xref ref-type="bibr" rid="B40">40</xref>). Compared to the large intake required by instruments, the small tidal volume of rats is greatly affected by slight mechanical force. In addition, this study focused only on the correlation between the propofol concentration in exhaled breath and that in plasma and lacked data concerning the effects on the brain and depth of anesthesia. Future studies should focus on online propofol monitoring for the rapid prediction of anesthesia depth.</p>
</sec>
<sec sec-type="conclusions" id="s5">
<title>Conclusions</title>
<p>The exhaled propofol concentration in rats can be monitored in real-time using the VUV-TOF MS. The strong correlation between exhaled and plasma propofol concentrations, well described by a linear model, indicates the potential to predict plasma propofol levels based on exhaled breath measurements. This study offers valuable insights and foundational data to support future clinical research.</p>
</sec>
</body>
<back>
<sec sec-type="data-availability" id="s6">
<title>Data availability statement</title>
<p>The original contributions presented in the study are included in the article/supplementary material, further inquiries can be directed to the corresponding author.</p>
</sec>
<sec sec-type="ethics-statement" id="s7">
<title>Ethics statement</title>
<p>The animal study was approved by Animal Ethics Committee of West China Hospital, Sichuan University. The study was conducted in accordance with the local legislation and institutional requirements.</p>
</sec>
<sec sec-type="author-contributions" id="s8">
<title>Author contributions</title>
<p>XL: Software, Validation, Visualization, Writing &#x02013; original draft, Writing &#x02013; review &#x00026; editing. PC: Methodology, Validation, Writing &#x02013; original draft, Writing &#x02013; review &#x00026; editing. XL: Data curation, Writing &#x02013; original draft, Writing &#x02013; review &#x00026; editing. YK: Methodology, Writing &#x02013; original draft, Writing &#x02013; review &#x00026; editing. ZZ: Resources, Writing &#x02013; original draft, Writing &#x02013; review &#x00026; editing. YD: Conceptualization, Writing &#x02013; original draft, Writing &#x02013; review &#x00026; editing. WZ: Conceptualization, Data curation, Formal analysis, Writing &#x02013; original draft, Writing &#x02013; review &#x00026; editing.</p>
</sec>
<sec sec-type="funding-information" id="s9">
<title>Funding</title>
<p>The author(s) declare financial support was received for the research, authorship, and/or publication of this article. This study was supported by the Sichuan Province Science and Technology Support Program (2023YFS0136) and the Young Scientists Fund of the National Natural Science Foundation of China (82304648).</p>
</sec>
<ack><p>The authors thank Aliben Science &#x00026; Technology for providing the gas calibration system.</p>
</ack>
<sec sec-type="COI-statement" id="conf1">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec sec-type="ai-statement" id="s10">
<title>Generative AI statement</title>
<p>The author(s) declare that no Gen AI was used in the creation of this manuscript.</p>
</sec>
<sec sec-type="disclaimer" id="s11">
<title>Publisher&#x00027;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ref-list>
<title>References</title>
<ref id="B1">
<label>1.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Walsh</surname> <given-names>CT</given-names></name></person-group>. <article-title>Propofol: Milk of Amnesia</article-title>. <source>Cell.</source> (<year>2018</year>) <volume>175</volume>:<fpage>10</fpage>&#x02013;<lpage>3</lpage>. <pub-id pub-id-type="doi">10.1016/j.cell.2018.08.031</pub-id><pub-id pub-id-type="pmid">30217361</pub-id></citation></ref>
<ref id="B2">
<label>2.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Irwin</surname> <given-names>MG</given-names></name> <name><surname>Chung</surname> <given-names>CKE</given-names></name> <name><surname>Ip</surname> <given-names>KY</given-names></name> <name><surname>Wiles</surname> <given-names>MD</given-names></name></person-group>. <article-title>Influence of propofol-based total intravenous anesthesia on peri-operative outcome measures: a narrative review</article-title>. <source>Anesthesia.</source> (<year>2020</year>) 75 Suppl <volume>1</volume>:<fpage>e90</fpage>&#x02013;<lpage>e100</lpage>. <pub-id pub-id-type="doi">10.1111/anae.14905</pub-id><pub-id pub-id-type="pmid">31903578</pub-id></citation></ref>
<ref id="B3">
<label>3.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Boshier</surname> <given-names>PR</given-names></name> <name><surname>Cushnir</surname> <given-names>JR</given-names></name> <name><surname>Mistry</surname> <given-names>V</given-names></name> <name><surname>Knaggs</surname> <given-names>A</given-names></name> <name><surname>&#x00160;pan&#x0011B;l</surname> <given-names>P</given-names></name> <name><surname>Smith</surname> <given-names>D</given-names></name> <etal/></person-group>. <article-title>On-line, real time monitoring of exhaled trace gases by SIFT-MS in the perioperative setting: a feasibility study</article-title>. <source>Analyst.</source> (<year>2011</year>) <volume>136</volume>:<fpage>3233</fpage>&#x02013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1039/C1AN15356K</pub-id><pub-id pub-id-type="pmid">21717028</pub-id></citation></ref>
<ref id="B4">
<label>4.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Grossherr</surname> <given-names>M</given-names></name> <name><surname>Varadarajan</surname> <given-names>B</given-names></name> <name><surname>Dibbelt</surname> <given-names>L</given-names></name> <name><surname>Schmucker</surname> <given-names>P</given-names></name> <name><surname>Gehring</surname> <given-names>H</given-names></name> <name><surname>Hengstenberg</surname> <given-names>A</given-names></name></person-group>. <article-title>Time course of ethanol and propofol exhalation after bolus injection using ion molecule reaction-mass spectrometry</article-title>. <source>Anal Bioanal Chem.</source> (<year>2011</year>) <volume>401</volume>:<fpage>2063</fpage>&#x02013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1007/s00216-010-4042-8</pub-id><pub-id pub-id-type="pmid">20680613</pub-id></citation></ref>
<ref id="B5">
<label>5.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhou</surname> <given-names>Q</given-names></name> <name><surname>Wang</surname> <given-names>W</given-names></name> <name><surname>Cang</surname> <given-names>H</given-names></name> <name><surname>Du</surname> <given-names>Y</given-names></name> <name><surname>Han</surname> <given-names>F</given-names></name> <name><surname>Chen</surname> <given-names>C</given-names></name> <etal/></person-group>. <article-title>On-line measurement of propofol using membrane inlet ion mobility spectrometer</article-title>. <source>Talanta.</source> (<year>2012</year>) <volume>98</volume>:<fpage>241</fpage>&#x02013;<lpage>6</lpage>. <pub-id pub-id-type="doi">10.1016/j.talanta.2012.07.001</pub-id><pub-id pub-id-type="pmid">22939154</pub-id></citation></ref>
<ref id="B6">
<label>6.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chen</surname> <given-names>X</given-names></name> <name><surname>Zhang</surname> <given-names>XL</given-names></name> <name><surname>Liu</surname> <given-names>L</given-names></name> <name><surname>Chen</surname> <given-names>Y</given-names></name> <name><surname>Piao</surname> <given-names>MY</given-names></name> <name><surname>Zhang</surname> <given-names>FJ</given-names></name> <etal/></person-group>. <article-title>Gas chromatograph-surface acoustic wave for quick real-time assessment of blood/exhaled gas ratio of propofol in humans</article-title>. <source>Br J Anaesth.</source> (<year>2014</year>) <volume>113</volume>:<fpage>807</fpage>&#x02013;<lpage>14</lpage>. <pub-id pub-id-type="doi">10.1093/bja/aeu193</pub-id><pub-id pub-id-type="pmid">25012583</pub-id></citation></ref>
<ref id="B7">
<label>7.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Butcher</surname> <given-names>DJ</given-names></name></person-group>. <article-title>Vacuum ultraviolet radiation for single-photoionization mass spectrometry: a review</article-title>. <source>Microchem J.</source> (<year>1999</year>) <volume>62</volume>:<fpage>354</fpage>&#x02013;<lpage>62</lpage>. <pub-id pub-id-type="doi">10.1006/mchj.1999.1745</pub-id></citation>
</ref>
<ref id="B8">
<label>8.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Li</surname> <given-names>X</given-names></name> <name><surname>Chang</surname> <given-names>P</given-names></name> <name><surname>Liu</surname> <given-names>X</given-names></name> <name><surname>Kang</surname> <given-names>Y</given-names></name> <name><surname>Zhao</surname> <given-names>Z</given-names></name> <name><surname>Duan</surname> <given-names>Y</given-names></name> <etal/></person-group>. <article-title>A preclinical study on online monitoring of exhaled ciprofol concentration by the ultraviolet time-of-flight spectrometer and prediction of anesthesia depth in beagles</article-title>. <source>J Pharm Biomed Anal.</source> (<year>2023</year>) <volume>235</volume>:<fpage>115621</fpage>. <pub-id pub-id-type="doi">10.1016/j.jpba.2023.115621</pub-id><pub-id pub-id-type="pmid">37572595</pub-id></citation></ref>
<ref id="B9">
<label>9.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>China National Food and Drug Administration</collab></person-group>. <source>Guiding Principles for Registration Review of Animal Testing in Medical Device Studies</source>. (<year>2021</year>). Available at: <ext-link ext-link-type="uri" xlink:href="https://amr.hainan.gov.cn/himpa/HICDME/zdyz/ylqx/202109/t20210928_3067786.html">https://amr.hainan.gov.cn/himpa/HICDME/zdyz/ylqx/202109/t20210928_3067786.html</ext-link> (accessed September 18, 2021).<pub-id pub-id-type="pmid">39493181</pub-id></citation></ref>
<ref id="B10">
<label>10.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Liao</surname> <given-names>J</given-names></name> <name><surname>Li</surname> <given-names>M</given-names></name> <name><surname>Huang</surname> <given-names>C</given-names></name> <name><surname>Yu</surname> <given-names>Y</given-names></name> <name><surname>Chen</surname> <given-names>Y</given-names></name> <name><surname>Gan</surname> <given-names>J</given-names></name> <etal/></person-group>. <article-title>Pharmacodynamics and pharmacokinetics of HSK3486, a novel 2,6-disubstituted phenol derivative as a general anesthetic</article-title>. <source>Front Pharmacol.</source> (<year>2022</year>) <volume>13</volume>:<fpage>830791</fpage>. <pub-id pub-id-type="doi">10.3389/fphar.2022.830791</pub-id><pub-id pub-id-type="pmid">35185584</pub-id></citation></ref>
<ref id="B11">
<label>11.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Li</surname> <given-names>X</given-names></name> <name><surname>Chang</surname> <given-names>P</given-names></name> <name><surname>Liu</surname> <given-names>X</given-names></name> <name><surname>Zhao</surname> <given-names>Z</given-names></name> <name><surname>Li</surname> <given-names>W</given-names></name> <name><surname>Kang</surname> <given-names>Y</given-names></name> <etal/></person-group>. <article-title>Calibration and validation of ultraviolet time-of-flight mass spectrometry for online measurement of exhaled ciprofol</article-title>. <source>Anal Methods.</source> (<year>2023</year>) <volume>15</volume>:<fpage>4179</fpage>&#x02013;<lpage>86</lpage>. <pub-id pub-id-type="doi">10.1039/d3ay01168b</pub-id><pub-id pub-id-type="pmid">37578256</pub-id></citation></ref>
<ref id="B12">
<label>12.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jang</surname> <given-names>SH</given-names></name> <name><surname>Yan</surname> <given-names>Z</given-names></name> <name><surname>Lazor</surname> <given-names>JA</given-names></name></person-group>. <article-title>Therapeutic drug monitoring: a patient management tool for precision medicine</article-title>. <source>Clin Pharmacol Ther.</source> (<year>2016</year>) <volume>99</volume>:<fpage>148</fpage>&#x02013;<lpage>50</lpage>. <pub-id pub-id-type="doi">10.2337/dc23-0492</pub-id><pub-id pub-id-type="pmid">37556796</pub-id></citation></ref>
<ref id="B13">
<label>13.</label>
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Hudson</surname> <given-names>AE</given-names></name> <name><surname>Herold</surname> <given-names>KF</given-names></name> <name><surname>Hemmings</surname> <given-names>HC</given-names></name></person-group>. <article-title>Pharmacology of inhaled anesthetics</article-title>. In: <source>Pharmacology and physiology for anesthesia</source>. <publisher-loc>London</publisher-loc>: <publisher-name>Elsevier.</publisher-name> (<year>2019</year>). p. <fpage>217</fpage>&#x02013;<lpage>240</lpage>.</citation>
</ref>
<ref id="B14">
<label>14.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Meyer</surname> <given-names>JU</given-names></name> <name><surname>Kullik</surname> <given-names>G</given-names></name> <name><surname>Wruck</surname> <given-names>N</given-names></name> <name><surname>K&#x000FC;ck</surname> <given-names>K</given-names></name> <name><surname>Manigel</surname> <given-names>J</given-names></name></person-group>. <article-title>Advanced technologies and devices for inhalational anesthetic drug dosing</article-title>. <source>Modern Anesthet.</source> (<year>2008</year>) <volume>182</volume>:<fpage>451</fpage>&#x02013;<lpage>70</lpage>. <pub-id pub-id-type="doi">10.1007/978-3-540-74806-9_21</pub-id><pub-id pub-id-type="pmid">18175104</pub-id></citation></ref>
<ref id="B15">
<label>15.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sahinovic</surname> <given-names>MM</given-names></name> <name><surname>Struys</surname> <given-names>MMRF</given-names></name> <name><surname>Absalom</surname> <given-names>AR</given-names></name></person-group>. <article-title>Clinical pharmacokinetics and pharmacodynamics of propofol</article-title>. <source>Clin Pharmacokinet</source>. (<year>2018</year>) <volume>57</volume>:<fpage>1539</fpage>&#x02013;<lpage>58</lpage>. <pub-id pub-id-type="doi">10.1007/s40262-018-0672-3</pub-id><pub-id pub-id-type="pmid">30019172</pub-id></citation></ref>
<ref id="B16">
<label>16.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Vretzakis</surname> <given-names>G</given-names></name> <name><surname>Dragoumanis</surname> <given-names>C</given-names></name> <name><surname>Ferdi</surname> <given-names>H</given-names></name> <name><surname>Papagiannopoulou</surname> <given-names>P</given-names></name></person-group>. <article-title>Influence of an external pacemaker on bispectral index</article-title>. <source>Eur J Anesthesiol.</source> (<year>2005</year>) <volume>22</volume>:<fpage>70</fpage>&#x02013;<lpage>2</lpage>. <pub-id pub-id-type="doi">10.1017/s0265021505230144</pub-id><pub-id pub-id-type="pmid">15816579</pub-id></citation></ref>
<ref id="B17">
<label>17.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kawanishi</surname> <given-names>S</given-names></name> <name><surname>Hamanami</surname> <given-names>K</given-names></name> <name><surname>Takahashi</surname> <given-names>T</given-names></name> <name><surname>Matsumi</surname> <given-names>M</given-names></name></person-group>. <article-title>Impact of beach chair position on the value of bispectral index during general anesthesia</article-title>. <source>Masui.</source> (<year>2012</year>) <volume>61</volume>:<fpage>820</fpage>&#x02013;<lpage>5</lpage>.</citation>
</ref>
<ref id="B18">
<label>18.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lee</surname> <given-names>SW</given-names></name> <name><surname>Choi</surname> <given-names>SE</given-names></name> <name><surname>Han</surname> <given-names>JH</given-names></name> <name><surname>Park</surname> <given-names>SW</given-names></name> <name><surname>Kang</surname> <given-names>WJ</given-names></name> <name><surname>Choi</surname> <given-names>YK</given-names></name></person-group>. <article-title>Effect of beach chair position on bispectral index values during arthroscopic shoulder surgery</article-title>. <source>Korean J Anesthesiol.</source> (<year>2014</year>) <volume>67</volume>:<fpage>235</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.4097/kjae.2014.67.4.235</pub-id><pub-id pub-id-type="pmid">25368780</pub-id></citation></ref>
<ref id="B19">
<label>19.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kurehara</surname> <given-names>K</given-names></name> <name><surname>Asano</surname> <given-names>N</given-names></name> <name><surname>Iwata</surname> <given-names>T</given-names></name> <name><surname>Yamaguchi</surname> <given-names>A</given-names></name> <name><surname>Kawano</surname> <given-names>Y</given-names></name> <name><surname>Furuya</surname> <given-names>H</given-names></name></person-group>. <article-title>The influence of ketamine on the bispectral index, the spectral edge frequency 90 and the frequency bands power during propofol anesthesia</article-title>. <source>Masui</source>. (<year>1999</year>) <volume>48</volume>:<fpage>611</fpage>&#x02013;<lpage>6</lpage>.<pub-id pub-id-type="pmid">10402812</pub-id></citation></ref>
<ref id="B20">
<label>20.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Harrison</surname> <given-names>GR</given-names></name> <name><surname>Critchley</surname> <given-names>AD</given-names></name> <name><surname>Mayhew</surname> <given-names>CA</given-names></name> <name><surname>Thompson</surname> <given-names>JM</given-names></name></person-group>. <article-title>Real-time breath monitoring of propofol and its volatile metabolites during surgery using a novel mass spectrometric technique: a feasibility study</article-title>. <source>Br J Anaesth.</source> (<year>2003</year>) <volume>91</volume>:<fpage>797</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1093/bja/aeg271</pub-id><pub-id pub-id-type="pmid">14633747</pub-id></citation></ref>
<ref id="B21">
<label>21.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kolka</surname> <given-names>AJ</given-names></name> <name><surname>Napolitano</surname> <given-names>JP</given-names></name> <name><surname>Filbey</surname> <given-names>AH</given-names></name> <name><surname>Ecke</surname> <given-names>GG</given-names></name></person-group>. <article-title>The ortho-alkylation of phenols J</article-title>. <source>Org Chem.</source> (<year>1957</year>) <volume>22</volume>:<fpage>642</fpage>&#x02013;<lpage>6</lpage>. <pub-id pub-id-type="doi">10.1021/jo01357a014</pub-id></citation>
</ref>
<ref id="B22">
<label>22.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wirtz</surname> <given-names>LM</given-names></name> <name><surname>Kreuer</surname> <given-names>S</given-names></name> <name><surname>Volk</surname> <given-names>T</given-names></name> <name><surname>H&#x000FC;ppe</surname> <given-names>T</given-names></name></person-group>. <article-title>Modern breath analysis</article-title>. <source>Med Klin Intensivmed Notfmed.</source> (<year>2019</year>) <volume>114</volume>:<fpage>655</fpage>&#x02013;<lpage>60</lpage>. <pub-id pub-id-type="doi">10.1007/s00063-019-0544-0</pub-id><pub-id pub-id-type="pmid">30725273</pub-id></citation></ref>
<ref id="B23">
<label>23.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mackay</surname> <given-names>D</given-names></name> <name><surname>Bobra</surname> <given-names>A</given-names></name> <name><surname>Chan</surname> <given-names>DW</given-names></name> <name><surname>Shiu</surname> <given-names>WY</given-names></name></person-group>. <article-title>Vapor-pressure correlations for low-volatility environmental chemicals</article-title>. <source>Environ Sci Technol.</source> (<year>1982</year>) <volume>16</volume>:<fpage>645</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1021/es00104a004</pub-id></citation>
</ref>
<ref id="B24">
<label>24.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Eger</surname> <given-names>EI</given-names> <suffix>II</suffix></name></person-group>. <article-title>The pharmacology of inhaled anesthetics</article-title>. <source>Semin Anesth WB Saunders.</source> (<year>2005</year>) <volume>24</volume>:<fpage>89</fpage>&#x02013;<lpage>100</lpage>. <pub-id pub-id-type="doi">10.1053/j.sane.2005.04.004</pub-id></citation>
</ref>
<ref id="B25">
<label>25.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Berchtold</surname> <given-names>C</given-names></name> <name><surname>Bosilkovska</surname> <given-names>M</given-names></name> <name><surname>Daali</surname> <given-names>Y</given-names></name> <name><surname>Walder</surname> <given-names>B</given-names></name> <name><surname>Zenobi</surname> <given-names>R</given-names></name></person-group>. <article-title>Real-time monitoring of exhaled drugs by mass spectrometry</article-title>. <source>Mass Spectrom Rev.</source> (<year>2014</year>) <volume>33</volume>:<fpage>394</fpage>&#x02013;<lpage>413</lpage>. <pub-id pub-id-type="doi">10.1002/mas.21393</pub-id><pub-id pub-id-type="pmid">24272872</pub-id></citation></ref>
<ref id="B26">
<label>26.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lorenz</surname> <given-names>D</given-names></name> <name><surname>Maurer</surname> <given-names>F</given-names></name> <name><surname>Trautner</surname> <given-names>K</given-names></name> <name><surname>Fink</surname> <given-names>T</given-names></name> <name><surname>H&#x000FC;ppe</surname> <given-names>T</given-names></name> <name><surname>Sessler</surname> <given-names>DI</given-names></name> <etal/></person-group>. <article-title>Adhesion of volatile propofol to breathing circuit tubing</article-title>. <source>J Breath Res.</source> (<year>2017</year>) <volume>11</volume>:<fpage>036005</fpage>. <pub-id pub-id-type="doi">10.1088/1752-7163/aa795d</pub-id><pub-id pub-id-type="pmid">28825414</pub-id></citation></ref>
<ref id="B27">
<label>27.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>M&#x000FC;ller-Wirtz</surname> <given-names>LM</given-names></name> <name><surname>Maurer</surname> <given-names>F</given-names></name> <name><surname>Brausch</surname> <given-names>T</given-names></name> <name><surname>Kiefer</surname> <given-names>D</given-names></name> <name><surname>Floss</surname> <given-names>M</given-names></name> <name><surname>Doneit</surname> <given-names>J</given-names></name> <etal/></person-group>. <article-title>Exhaled propofol concentrations correlate with plasma and brain tissue concentrations in rats</article-title>. <source>Anesth Analg.</source> (<year>2021</year>) <volume>132</volume>:<fpage>110</fpage>&#x02013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1213/ANE.0000000000004701</pub-id><pub-id pub-id-type="pmid">32118620</pub-id></citation></ref>
<ref id="B28">
<label>28.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Braathen</surname> <given-names>MR</given-names></name> <name><surname>Rimstad</surname> <given-names>I</given-names></name> <name><surname>Dybvik</surname> <given-names>T</given-names></name> <name><surname>Nyg&#x000E5;rd</surname> <given-names>S</given-names></name> <name><surname>Raeder</surname> <given-names>J</given-names></name></person-group>. <article-title>Online exhaled propofol monitoring in normal-weight and obese surgical patients</article-title>. <source>Acta Anaesthesiol Scand.</source> (<year>2022</year>) <volume>66</volume>:<fpage>598</fpage>&#x02013;<lpage>605</lpage>. <pub-id pub-id-type="doi">10.1111/aas.14043</pub-id><pub-id pub-id-type="pmid">35138633</pub-id></citation></ref>
<ref id="B29">
<label>29.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Liu</surname> <given-names>Y</given-names></name> <name><surname>Gong</surname> <given-names>Y</given-names></name> <name><surname>Wang</surname> <given-names>C</given-names></name> <name><surname>Wang</surname> <given-names>X</given-names></name> <name><surname>Zhou</surname> <given-names>Q</given-names></name> <name><surname>Wang</surname> <given-names>D</given-names></name> <etal/></person-group>. <article-title>Online breath analysis of propofol during anesthesia: clinical application of membrane inlet-ion mobility spectrometry</article-title>. <source>Acta Anaesthesiol Scand.</source> (<year>2015</year>) <volume>59</volume>:<fpage>319</fpage>&#x02013;<lpage>28</lpage>. <pub-id pub-id-type="doi">10.1111/aas.12448</pub-id><pub-id pub-id-type="pmid">25565144</pub-id></citation></ref>
<ref id="B30">
<label>30.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Maurer</surname> <given-names>F</given-names></name> <name><surname>Walter</surname> <given-names>L</given-names></name> <name><surname>Geiger</surname> <given-names>M</given-names></name> <name><surname>Baumbach</surname> <given-names>JI</given-names></name> <name><surname>Sessler</surname> <given-names>DI</given-names></name> <name><surname>Volk</surname> <given-names>T</given-names></name> <etal/></person-group>. <article-title>Calibration and validation of a MCC/IMS prototype for exhaled propofol online measurement</article-title>. <source>J Pharm Biomed Anal.</source> (<year>2017</year>) <volume>145</volume>:<fpage>293</fpage>&#x02013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1016/j.jpba.2017.06.052</pub-id><pub-id pub-id-type="pmid">28704718</pub-id></citation></ref>
<ref id="B31">
<label>31.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Maurer</surname> <given-names>F</given-names></name> <name><surname>Lorenz</surname> <given-names>DJ</given-names></name> <name><surname>Pielsticker</surname> <given-names>G</given-names></name> <name><surname>Volk</surname> <given-names>T</given-names></name> <name><surname>Sessler</surname> <given-names>DI</given-names></name> <name><surname>Baumbach</surname> <given-names>JI</given-names></name> <etal/></person-group>. <article-title>Adherence of volatile propofol to various types of plastic tubing</article-title>. <source>J Breath Res.</source> (<year>2017</year>) <volume>11</volume>:<fpage>016009</fpage>. <pub-id pub-id-type="doi">10.1088/1752-7163/aa567e</pub-id><pub-id pub-id-type="pmid">28049865</pub-id></citation></ref>
<ref id="B32">
<label>32.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wolf</surname> <given-names>A</given-names></name> <name><surname>Baumbach</surname> <given-names>JI</given-names></name> <name><surname>Kleber</surname> <given-names>A</given-names></name> <name><surname>Maurer</surname> <given-names>F</given-names></name> <name><surname>Maddula</surname> <given-names>S</given-names></name> <name><surname>Favrod</surname> <given-names>P</given-names></name> <etal/></person-group>. <article-title>Multi-capillary column-ion mobility spectrometer (MCC-IMS) breath analysis in ventilated rats: a model with the feasibility of long-term measurements</article-title>. <source>J Breath Res.</source> (<year>2014</year>) <volume>8</volume>:<fpage>016006</fpage>. <pub-id pub-id-type="doi">10.1088/1752-7155/8/1/016006</pub-id><pub-id pub-id-type="pmid">24566204</pub-id></citation></ref>
<ref id="B33">
<label>33.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kreuer</surname> <given-names>S</given-names></name> <name><surname>Hauschild</surname> <given-names>A</given-names></name> <name><surname>Fink</surname> <given-names>T</given-names></name> <name><surname>Baumbach</surname> <given-names>JI</given-names></name> <name><surname>Maddula</surname> <given-names>S</given-names></name> <name><surname>Volk</surname> <given-names>T</given-names></name></person-group>. <article-title>Two different approaches for pharmacokinetic modeling of exhaled drug concentrations</article-title>. <source>Sci Rep.</source> (<year>2014</year>) <volume>4</volume>:<fpage>5423</fpage>. <pub-id pub-id-type="doi">10.1038/srep05423</pub-id><pub-id pub-id-type="pmid">24957852</pub-id></citation></ref>
<ref id="B34">
<label>34.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Anderson</surname> <given-names>JC</given-names></name> <name><surname>Babb</surname> <given-names>AL</given-names></name> <name><surname>Hlastala</surname> <given-names>MP</given-names></name></person-group>. <article-title>Modeling soluble gas exchange in the airways and alveoli</article-title>. <source>Ann Biomed Eng.</source> (<year>2003</year>) <volume>31</volume>:<fpage>1402</fpage>&#x02013;<lpage>22</lpage>. <pub-id pub-id-type="doi">10.1114/1.1630600</pub-id><pub-id pub-id-type="pmid">14758930</pub-id></citation></ref>
<ref id="B35">
<label>35.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Anderson</surname> <given-names>JC</given-names></name> <name><surname>Hlastala</surname> <given-names>MP</given-names></name></person-group>. <article-title>Breath tests and airway gas exchange</article-title>. <source>Pulm Pharmacol Ther.</source> (<year>2007</year>) <volume>20</volume>:<fpage>112</fpage>&#x02013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1016/j.pupt.2005.12.002</pub-id><pub-id pub-id-type="pmid">16413216</pub-id></citation></ref>
<ref id="B36">
<label>36.</label>
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Kader</surname> <given-names>AA</given-names></name> <name><surname>Saltveit</surname> <given-names>ME</given-names></name></person-group>. <article-title>Respiration and gas exchange</article-title>. In: <source>Postharvest Physiology and Pathology of Vegetables</source>. <publisher-loc>Boca Raton, FL</publisher-loc>: <publisher-name>CRC Press</publisher-name>. (<year>2002</year>). p. <fpage>31</fpage>&#x02013;<lpage>56</lpage>.</citation>
</ref>
<ref id="B37">
<label>37.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hornuss</surname> <given-names>C</given-names></name> <name><surname>Praun</surname> <given-names>S</given-names></name> <name><surname>Villinger</surname> <given-names>J</given-names></name> <name><surname>Dornauer</surname> <given-names>A</given-names></name> <name><surname>Moehnle</surname> <given-names>P</given-names></name> <name><surname>Dolch</surname> <given-names>M</given-names></name> <etal/></person-group>. <article-title>Real-time monitoring of propofol in expired air in humans undergoing total intravenous anesthesia</article-title>. <source>Anesthesiology.</source> (<year>2007</year>) <volume>106</volume>:<fpage>665</fpage>&#x02013;<lpage>74</lpage>. <pub-id pub-id-type="doi">10.1097/01.anes.0000264746.01393.e0</pub-id><pub-id pub-id-type="pmid">17413903</pub-id></citation></ref>
<ref id="B38">
<label>38.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Takita</surname> <given-names>A</given-names></name> <name><surname>Masui</surname> <given-names>K</given-names></name> <name><surname>Kazama</surname> <given-names>T</given-names></name></person-group>. <article-title>On-line monitoring of end-tidal propofol concentration in anesthetized patients</article-title>. <source>Anesthesiology.</source> (<year>2007</year>) <volume>106</volume>:<fpage>659</fpage>&#x02013;<lpage>64</lpage>. <pub-id pub-id-type="doi">10.1097/01.anes.0000264745.63275.59</pub-id><pub-id pub-id-type="pmid">17413902</pub-id></citation></ref>
<ref id="B39">
<label>39.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lawal</surname> <given-names>O</given-names></name> <name><surname>Ahmed</surname> <given-names>WM</given-names></name> <name><surname>Nijsen</surname> <given-names>TME</given-names></name> <name><surname>Goodacre</surname> <given-names>R</given-names></name> <name><surname>Fowler</surname> <given-names>SJ</given-names></name></person-group>. <article-title>Exhaled breath analysis: a review of &#x02018;breath-taking&#x00027;methods for off-line analysis</article-title>. <source>Metabolomics.</source> (<year>2017</year>) <volume>13</volume>:<fpage>1</fpage>&#x02013;<lpage>16</lpage>. <pub-id pub-id-type="doi">10.1007/s11306-017-1241-8</pub-id><pub-id pub-id-type="pmid">28867989</pub-id></citation></ref>
<ref id="B40">
<label>40.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dong</surname> <given-names>H</given-names></name> <name><surname>Zhang</surname> <given-names>F</given-names></name> <name><surname>Chen</surname> <given-names>J</given-names></name> <name><surname>Yu</surname> <given-names>Q</given-names></name> <name><surname>Zhong</surname> <given-names>Y</given-names></name> <name><surname>Liu</surname> <given-names>J</given-names></name> <etal/></person-group>. <article-title>Evaluating propofol concentration in blood from exhaled gas using a breathing-related partition coefficient</article-title>. <source>Anesth Analg.</source> (<year>2020</year>) <volume>130</volume>:<fpage>958</fpage>&#x02013;<lpage>66</lpage>. <pub-id pub-id-type="doi">10.1213/ANE.0000000000004225</pub-id><pub-id pub-id-type="pmid">31124837</pub-id></citation></ref>
</ref-list>
</back>
</article>