<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" article-type="research-article" dtd-version="2.3" xml:lang="EN">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Vet. Sci.</journal-id>
<journal-title>Frontiers in Veterinary Science</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Vet. Sci.</abbrev-journal-title>
<issn pub-type="epub">2297-1769</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fvets.2023.1254340</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Veterinary Science</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Diagnostic agreement between three point-of-care glucose and &#x03B2;-hydroxybutyrate meters and reference laboratory methods in stingrays</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Dannemiller</surname>
<given-names>Nicholas G.</given-names>
</name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="corresp" rid="c001"><sup>&#x002A;</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/2363281/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation"/>
<role content-type="https://credit.niso.org/contributor-roles/data-curation"/>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Cray</surname>
<given-names>Carolyn</given-names>
</name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/675203/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Westmoreland</surname>
<given-names>Lori S.</given-names>
</name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Christiansen</surname>
<given-names>Emily F.</given-names>
</name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing"/>
</contrib>
</contrib-group>
<aff id="aff1"><sup>1</sup><institution>Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University</institution>, <addr-line>Raleigh, NC</addr-line>, <country>United States</country></aff>
<aff id="aff2"><sup>2</sup><institution>North Carolina Aquariums</institution>, <addr-line>Raleigh, NC</addr-line>, <country>United States</country></aff>
<aff id="aff3"><sup>3</sup><institution>Division of Comparative Pathology, Department of Pathology and Laboratory Medicine, University of Miami Miller School of Medicine</institution>, <addr-line>Miami, FL</addr-line>, <country>United States</country></aff>
<author-notes>
<fn fn-type="edited-by" id="fn0001">
<p>Edited by: Natalie D. Mylniczenko, Walt Disney World, United States</p>
</fn>
<fn fn-type="edited-by" id="fn0002">
<p>Reviewed by: Alexandra Schoen, University of Manitoba, Canada; Lily Parkinson, Chicago Zoological Society, United States</p>
</fn>
<corresp id="c001">&#x002A;Correspondence: Nicholas G. Dannemiller, <email>ngdannem@ncsu.edu</email></corresp>
</author-notes>
<pub-date pub-type="epub">
<day>20</day>
<month>12</month>
<year>2023</year>
</pub-date>
<pub-date pub-type="collection">
<year>2023</year>
</pub-date>
<volume>10</volume>
<elocation-id>1254340</elocation-id>
<history>
<date date-type="received">
<day>06</day>
<month>07</month>
<year>2023</year>
</date>
<date date-type="accepted">
<day>28</day>
<month>11</month>
<year>2023</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x00A9; 2023 Dannemiller, Cray, Westmoreland and Christiansen.</copyright-statement>
<copyright-year>2023</copyright-year>
<copyright-holder>Dannemiller, Cray, Westmoreland and Christiansen</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<p>Point-of-care (POC) glucose and &#x03B2;-hydroxybutyrate (&#x03B2;-HB) meters can potentially provide rapid insight into an elasmobranch&#x2019;s metabolic state in clinical and field research settings. This study evaluated the diagnostic agreement of three commercial POC meters against reference laboratory methods for glucose and &#x03B2;-HB concentrations in stingrays. Blood was collected during anesthetized exams from 28 stingrays representing four species: cownose rays (<italic>Rhinoptera bonasus</italic>), Atlantic stingrays (<italic>Hypanus sabina</italic>), southern stingrays (<italic>Hypanus americanus</italic>), and yellow stingrays (<italic>Urobatis jamaicensis</italic>). Glucose and &#x03B2;-HB concentrations were measured with each POC meter using whole blood and plasma; in parallel, plasma glucose and &#x03B2;-HB concentrations were measured via reference laboratory methods. Agreement between POC meters and reference laboratory methods was assessed using Bland&#x2013;Altman methods, Passing-Bablok regression, observed total error, percent relative error, and linear mixed effect models. Plasma glucose and &#x03B2;-HB concentrations determined by reference laboratory methods ranged from &#x003C;20&#x2013;63&#x2009;mg/dL to 0.05&#x2013;5.38&#x2009;mmol/L, respectively. One human POC meter&#x2014;the Precision Xtra&#x2014;showed the greatest agreement with reference laboratory methods when measuring glucose with whole blood [mean bias and 95% CI: 0 (&#x2212;3&#x2013;4) mg/dL] and &#x03B2;-HB with plasma [mean bias and 95% CI: 0.1 (&#x2212;0.04&#x2013;0.2) mmol/L]. Stingray sex, weight, buffy coat, and packed cell volume did not significantly affect the agreement between POC meters and reference laboratory methods. Across all three POC meters, mean bias and imprecision for plasma &#x03B2;-HB concentrations were relatively small (0&#x2013;0.1&#x2009;mmol/L and 0%, respectively). Utilizing POC meters to measure glucose and &#x03B2;-HB in stingrays may be viable when reference methods are unavailable.</p>
</abstract>
<kwd-group>
<kwd>batoid</kwd>
<kwd>clinical pathology</kwd>
<kwd>elasmobranch</kwd>
<kwd>ketone</kwd>
<kwd>metabolism</kwd>
</kwd-group>
<counts>
<fig-count count="4"/>
<table-count count="3"/>
<equation-count count="5"/>
<ref-count count="51"/>
<page-count count="11"/>
<word-count count="7429"/>
</counts>
<custom-meta-wrap>
<custom-meta>
<meta-name>section-at-acceptance</meta-name>
<meta-value>Zoological Medicine</meta-value>
</custom-meta>
</custom-meta-wrap>
</article-meta>
</front>
<body>
<sec sec-type="intro" id="sec1">
<label>1</label>
<title>Introduction</title>
<p>Elasmobranchs (sharks, skates, and rays) are an ancient and diverse group of cartilaginous fish that play essential ecologic roles in aquatic ecosystems globally. Over 200 stingray species are grouped in the order Myliobatiformes, suborder Myliobatoidei (<xref ref-type="bibr" rid="ref1">1</xref>). Most stingrays are demersal and can be found in tropical to subtropical marine or freshwater habitats. Stingray species are increasingly listed as vulnerable or endangered on the International Union for Conservation of Nature Red List of Threatened Species, an unfortunate trend shared by all elasmobranchs, with almost 1/3 being threatened with extinction (<xref ref-type="bibr" rid="ref2">2</xref>). Consequently, stingrays are common in public aquariums due to their ecological importance and increasing need for conservation.</p>
<p>One unique physiologic feature of elasmobranchs is their preferential use of ketone bodies&#x2014;especially &#x03B2;-hydroxybutyrate (&#x03B2;-HB)&#x2014;rather than fatty acids for aerobic metabolism under normal conditions, predominately in skeletal and cardiac muscle (<xref ref-type="bibr" rid="ref3 ref4 ref5">3&#x2013;5</xref>). Besides providing buoyancy, elasmobranchs&#x2019; large, lipid-dense livers serve as ketogenic powerhouses (<xref ref-type="bibr" rid="ref4">4</xref>). Within the liver, acetyl coenzyme A is formed from long-chain fatty acids by mitochondrial &#x03B2;-oxidation and utilized in numerous metabolic reactions, including generating ketone bodies. Ketone bodies are highly water-soluble, energy-rich fuels exported to extra-hepatic tissues without the need for protein-binding (<xref ref-type="bibr" rid="ref3">3</xref>). Furthermore, ketone bodies likely play a significant role in supporting metabolism during periods of fasting in elasmobranchs (<xref ref-type="bibr" rid="ref3 ref4 ref5 ref6">3&#x2013;6</xref>). While the concentration of ketone bodies in fed elasmobranchs is similar to that observed in fasted (0&#x2013;3&#x2009;mmol/L) or ketoacidotic (&#x003E; 3&#x2009;mmol/L) mammals, marked ketosis has been found during starvation or prolonged fasting (<xref ref-type="bibr" rid="ref4">4</xref>).</p>
<p>Glucose is potentially of less metabolic importance in elasmobranchs, although differences between tissues, species, and metabolic states exist (<xref ref-type="bibr" rid="ref3 ref4 ref5">3&#x2013;5</xref>, <xref ref-type="bibr" rid="ref7">7</xref>, <xref ref-type="bibr" rid="ref8">8</xref>). Plasma glucose concentrations are often low relative to teleosts and terrestrial vertebrates and appear relatively unchanged after feeding or during long-term fasting (<xref ref-type="bibr" rid="ref3">3</xref>). Some elasmobranch species reportedly tolerate wide ranges of plasma glucose concentrations with no observed clinical effects (<xref ref-type="bibr" rid="ref3">3</xref>). Nevertheless, a stress-induced increase in catecholamines or corticosteroids (e.g., 1&#x03B1;-hydroxycorticosterone) has been speculated to possibly correlate with increased glucose mobilization, which may reflect increased demand as an oxidative fuel source or supply increased rates of anaerobic glycolysis (<xref ref-type="bibr" rid="ref3 ref4 ref5">3&#x2013;5</xref>, <xref ref-type="bibr" rid="ref9">9</xref>, <xref ref-type="bibr" rid="ref10">10</xref>). This is best highlighted by the hyperglycemia observed in elasmobranchs as a response to various stressors, including capture, handling, and transport (<xref ref-type="bibr" rid="ref10 ref11 ref12 ref13">10&#x2013;13</xref>).</p>
<p>Conventional measurement of glucose and &#x03B2;-HB concentrations in veterinary medicine requires serum or plasma to be submitted to a reference laboratory. As an alternative to laboratory-based assays in human and veterinary medicine, point-of-care (POC) meters typically provide rapid results, require smaller sample volumes, and require no centrifugation or cold chain before testing (<xref ref-type="bibr" rid="ref14">14</xref>). Within veterinary medicine, the diagnostic accuracy of POC glucose and &#x03B2;-HB meters have been explored in multiple domestic (<xref ref-type="bibr" rid="ref15 ref16 ref17 ref18 ref19 ref20 ref21">15&#x2013;21</xref>) and non-domestic species (<xref ref-type="bibr" rid="ref22 ref23 ref24 ref25 ref26 ref27 ref28">22&#x2013;28</xref>). Point-of-care glucose and &#x03B2;-HB meters may aid veterinarians, researchers, and wildlife managers working with elasmobranchs, including stingrays, by providing almost instant insight into their physiologic stress or metabolic state.</p>
<p>This study evaluated the diagnostic agreement of three commercial POC glucose and &#x03B2;-HB meters with reference laboratory methods for glucose and &#x03B2;-HB concentrations in stingrays. We hypothesized that the results from the POC meters evaluated would have sufficient agreement with reference laboratory methods and precision for clinical and field research purposes for glucose and &#x03B2;-HB concentrations in stingrays.</p>
</sec>
<sec sec-type="materials|methods" id="sec2">
<label>2</label>
<title>Materials and methods</title>
<sec id="sec3">
<label>2.1</label>
<title>POC meters and reference laboratory</title>
<p>Glucose and &#x03B2;-HB concentrations determined by three commercially available POC meters were compared to results from reference laboratory methods. Each meter measures glucose or &#x03B2;-HB concentrations independently using corresponding test strips. All three meters measure glucose concentration via a glucose-1-dehydrogenase enzymatic reaction in which glucose is converted to gluconolactone using a coenzyme to convert nicotinamide adenine dinucleotide (NAD+) to its reduced form NADH. NADH is re-oxidized to NAD+ by a redox mediator, which is measured via amperometry (i.e., an electrical current) and is directly proportional to glucose concentration (<xref ref-type="bibr" rid="ref14">14</xref>). Similarly, all three meters measure &#x03B2;-HB concentration via a &#x03B2;-HB-dehydrogenase enzymatic reaction in which &#x03B2;-HB is converted to acetoacetate, leading to a concurrent equimolar reduction of NAD+ to NADH. NADH is re-oxidized to NAD+ by a redox mediator, which is measured via amperometry (i.e., an electrical current) and is directly proportional to &#x03B2;-HB concentration (<xref ref-type="bibr" rid="ref14">14</xref>). Each meter and its respective test strips were stored and operated following manufacturer instructions; only the correct corresponding test strips provided by the manufacturer were used for each respective meter. Before all data collection, meters were calibrated following manufacturer instructions. None of the meters were operated outside their recommended temperature (10&#x2013;50&#x00B0;C or 50&#x2013;122&#x00B0;F) and humidity (10&#x2013;90%) ranges.</p>
<p>The first POC meter evaluated was the BHBCheck Plus Blood Ketone &#x0026; Glucose Monitoring System (PortaCheck, Moorestown, NJ, United States), a veterinary-licensed POC meter that requires 0.7&#x2009;&#x03BC;L of whole blood, measures glucose concentrations within 20&#x2013;600&#x2009;mg/dL, and &#x03B2;-HB concentrations within 0.1&#x2013;8.0&#x2009;mmol/L. The BHBCheck Plus meter is intended for heparinized or non-heparinized bovine venous whole blood with a 20&#x2013;40% packed cell volume (PCV).</p>
<p>The second POC meter evaluated was the Precision Xtra Blood Glucose &#x0026; Ketone Monitoring System (Abbott Laboratories, Chicago, IL, United States), a human-licensed POC meter that requires 1.5&#x2009;&#x03BC;L of whole blood, measures glucose concentrations within 20&#x2013;500&#x2009;mg/dL, and &#x03B2;-HB concentrations within 0&#x2013;8.0&#x2009;mmol/L. The Precision Xtra meter is intended for freshly drawn human capillary whole blood with a 30&#x2013;60% PCV.</p>
<p>The third POC meter evaluated was the Nova Vet&#x2122; Ketone/Glucose Meter (Nova Biomedical, Waltham, MA, United States), a veterinary-licensed POC meter that requires 0.4&#x2009;&#x03BC;L whole blood for glucose and 0.8&#x2009;&#x03BC;L whole blood for &#x03B2;-HB, measures glucose concentrations within 20&#x2013;600&#x2009;mg/dL, and &#x03B2;-HB concentrations within 0.1&#x2013;8.0&#x2009;mmol/L. The Nova Vet&#x2122; meter is intended for heparinized or non-heparinized bovine whole blood with a 25&#x2013;60% PCV.</p>
<p>Plasma glucose and &#x03B2;-HB concentrations were measured using a VITROS&#x00AE; 5600 analyzer (Ortho Clinical Diagnostics, Rochester, NY, United States) maintained at the reference laboratory (University of Miami, Miami, FL, United States). The analyzer is maintained per manufacturer instructions and quality assurance best practices. Glucose was determined by a colorimetric glucose oxidase assay based on peroxidase-catalyzed oxidative coupling, producing a red-colored quinoneimine dye with color intensity directly proportional to glucose concentration (Vitro glucose reagent, Ortho Clinical Diagnostics, Rochester, NY, United States). &#x03B2;-HB was determined via a colorimetric &#x03B2;-HB dehydrogenase assay based on the reduction of the tetrazolium salt INT to a red-colored formazan dye with a color intensity directly proportional to &#x03B2;-HB concentration (Stanbio Chemistry Beta-Hydroxybutyrate LiquiColor&#x00AE; Assay, EKF Diagnostics USA, Boerne, TX, United States). All assays were run per manufacturer instructions.</p>
</sec>
<sec id="sec4">
<label>2.2</label>
<title>Animals and sampling</title>
<p>Twenty-eight stingrays (15 males, 13 females) under managed care at the North Carolina Aquariums at Fort Fisher, Pine Knoll Shores, and Roanoke Island underwent routine annual preventative health exams and phlebotomy between September 2022 and October 2023. Four species were represented in the sample population: cownose rays (<italic>Rhinoptera bonasus</italic>, <italic>n</italic>&#x2009;=&#x2009;6, min-max weight: 3.85&#x2013;6.8&#x2009;kg), Atlantic stingrays (<italic>Hypanus sabina</italic>, <italic>n</italic>&#x2009;=&#x2009;10, min-max weight: 0.8&#x2013;1.8&#x2009;kg), southern stingrays (<italic>Hypanus americanus</italic>, <italic>n</italic>&#x2009;=&#x2009;4, min-max weight: 5.4&#x2013;9.2&#x2009;kg), and yellow stingrays (<italic>Urobatis jamaicensis</italic>, <italic>n</italic>&#x2009;=&#x2009;8, min-max weight: 0.6&#x2013;1.65&#x2009;kg). Stingrays were deemed clinically healthy for study inclusion via absence of abnormalities on physical exam (e.g., skin lesions, color changes, coelomic distension, etc.). All animals were fasted for 12&#x2013;48&#x2009;h and efficiently captured via a net from a holding or exhibit system in &#x003C;5&#x2009;min. Stingrays were anesthetized using 75&#x2013;100&#x2009;mg/L MS-222 buffered 1:1 by weight with sodium bicarbonate or marine buffer. After each stingray reached adequate anesthetic depth (approximately 5&#x2013;10&#x2009;min), blood was collected from a pectoral fin or mesopterygial vessel as previously described, using heparinized 22-gauge needles and 3&#x2009;mL syringes (<xref ref-type="bibr" rid="ref29">29</xref>). Needles and syringes were pre-heparinized before phlebotomy by aspirating a small volume of 1,000&#x2009;U/mL sodium heparin and forcefully expelling it. Stingray handling and sampling was performed according to procedures approved by North Carolina State University&#x2019;s Institutional Animal Care and Use Committee (IACUC #21&#x2013;117).</p>
</sec>
<sec id="sec5">
<label>2.3</label>
<title>Data collection</title>
<p>Immediately following phlebotomy, heparinized whole blood glucose and &#x03B2;-HB concentrations were measured using all three POC meters in a randomized order. Microhematocrit tubes were filled with heparinized whole blood, sealed with clay, and centrifuged for 5&#x2009;min at 10,000&#x2009;<italic>g</italic> (PowerSpin&#x2122; MH Centrifuge, UNICO, Dayton, NJ, United States). PCV and buffy coat (BC) were read using a hematocrit capillary tube reader (Veterinary Information Network&#x00AE;, Inc., Davis, CA, United States); total solids (TS) were determined via a handheld clinical refractometer (Jorgensen Laboratories, LLC, Loveland, CO, United States). The remainder of the heparinized whole blood sample was kept in a smaller cooler on ice until being centrifuged for 5&#x2009;min at 3,000&#x2009;<italic>g</italic> (Mini Centrifuge, Bio-Rad Laboratories, Inc., Hercules, CA, United States) within 1&#x2009;h of sample collection. Heparinized plasma was separated from packed red blood cells (RBCs) using a disposable pipette, and plasma glucose and &#x03B2;-HB concentrations were measured using all three POC meters. The remaining plasma was placed in a 2-mL cryovial and shipped overnight to the glucose and &#x03B2;-HB reference laboratory (University of Miami, Miami, FL, United States). To measure POC meter precision (i.e., intra-assay variability or repeatability), heparinized whole blood glucose and &#x03B2;-HB concentrations were measured with each POC meter five times in rapid succession immediately following phlebotomy in a subset of two yellow stingrays. Heparinized plasma glucose and &#x03B2;-HB concentrations were measured with each POC meter five times in rapid succession immediately following centrifugation.</p>
</sec>
<sec id="sec6">
<label>2.4</label>
<title>Statistical analyses</title>
<p>For glucose and &#x03B2;-HB concentrations below the lower limit of quantification (LLOQ) of the three POC meters and reference laboratory analyzer, imputation was performed by substituting half of the respective instrument&#x2019;s LLOQ (e.g., if the LLOQ was 20&#x2009;mg/dL, 10&#x2009;mg/dL was inputted). To date, there is no widespread consensus on handling data below the LLOQ of an instrument (<xref ref-type="bibr" rid="ref30">30</xref>). This study used imputation with half the LLOQ because it introduces less bias into the estimates than other single imputation approaches (<xref ref-type="bibr" rid="ref30">30</xref>, <xref ref-type="bibr" rid="ref31">31</xref>). Summary statistics for glucose and &#x03B2;-HB were compiled for the three POC meters and reference laboratory analyzer. Using reference laboratory results, summary statistics of glucose and &#x03B2;-HB concentrations were also compiled by stingray species.</p>
<p>The diagnostic agreement (i.e., accuracy) between the three POC meters and reference laboratory results was assessed by calculating the observed total error (TE<sub>obs</sub>) and percent relative error, as well as using Bland&#x2013;Altman methods (<xref ref-type="bibr" rid="ref32">32</xref>) and Passing-Bablok regression (<xref ref-type="bibr" rid="ref33">33</xref>, <xref ref-type="bibr" rid="ref34">34</xref>) for both glucose and &#x03B2;-HB using whole blood and plasma. The precision (i.e., intra-assay variability or repeatability) of the three POC meters for both glucose and &#x03B2;-HB using whole blood and plasma was assessed by calculating the percent coefficient of variation (CV) using five replicates with <xref ref-type="disp-formula" rid="EQ1">Equation 1</xref>:</p>
<disp-formula id="EQ1">
<label>(1)</label>
<mml:math id="M1">
<mml:mi>C</mml:mi>
<mml:mi>V</mml:mi>
<mml:mspace width="0.25em"/>
<mml:mfenced open="(" close=")">
<mml:mo>%</mml:mo>
</mml:mfenced>
<mml:mo>=</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mi mathvariant="italic">Standard</mml:mi>
<mml:mspace width="0.25em"/>
<mml:mi mathvariant="italic">Deviatio</mml:mi>
<mml:msub>
<mml:mi>n</mml:mi>
<mml:mrow>
<mml:mi>P</mml:mi>
<mml:mi>O</mml:mi>
<mml:mi>C</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mrow>
<mml:mi>M</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>a</mml:mi>
<mml:msub>
<mml:mi>n</mml:mi>
<mml:mrow>
<mml:mi>P</mml:mi>
<mml:mi>O</mml:mi>
<mml:mi>C</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:mfrac>
<mml:mo>&#x00D7;</mml:mo>
<mml:mn>100</mml:mn>
</mml:math>
</disp-formula>
<p>Percent bias and TE<sub>obs</sub> of the three POC meters for both glucose and &#x03B2;-HB using whole blood and plasma were calculated with <xref ref-type="disp-formula" rid="EQ2">Equations 2</xref> and <xref ref-type="disp-formula" rid="EQ3">3</xref>, respectively:</p>
<disp-formula id="EQ2">
<label>(2)</label>
<mml:math id="M2">
<mml:mi mathvariant="italic">Bias</mml:mi>
<mml:mspace width="0.25em"/>
<mml:mfenced open="(" close=")">
<mml:mo>%</mml:mo>
</mml:mfenced>
<mml:mo>=</mml:mo>
<mml:mfenced open="|" close="|">
<mml:mfrac>
<mml:mrow>
<mml:mi>M</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>a</mml:mi>
<mml:msub>
<mml:mi>n</mml:mi>
<mml:mi mathvariant="italic">Reference</mml:mi>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>M</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>a</mml:mi>
<mml:msub>
<mml:mi>n</mml:mi>
<mml:mrow>
<mml:mi>P</mml:mi>
<mml:mi>O</mml:mi>
<mml:mi>C</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mrow>
<mml:mi>M</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>a</mml:mi>
<mml:msub>
<mml:mi>n</mml:mi>
<mml:mi mathvariant="italic">Reference</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mfrac>
</mml:mfenced>
<mml:mo>&#x00D7;</mml:mo>
<mml:mn>100</mml:mn>
</mml:math>
</disp-formula>
<disp-formula id="EQ3">
<label>(3)</label>
<mml:math id="M3">
<mml:mi>T</mml:mi>
<mml:msub>
<mml:mi>E</mml:mi>
<mml:mrow>
<mml:mi>o</mml:mi>
<mml:mi>b</mml:mi>
<mml:mi>s</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mspace width="0.25em"/>
<mml:mfenced open="(" close=")">
<mml:mo>%</mml:mo>
</mml:mfenced>
<mml:mo>=</mml:mo>
<mml:mn>2</mml:mn>
<mml:mo>&#x00D7;</mml:mo>
<mml:mi>C</mml:mi>
<mml:mi>V</mml:mi>
<mml:mspace width="0.25em"/>
<mml:mfenced open="(" close=")">
<mml:mo>%</mml:mo>
</mml:mfenced>
<mml:mo>+</mml:mo>
<mml:mi mathvariant="italic">Bias</mml:mi>
<mml:mspace width="0.25em"/>
<mml:mfenced open="(" close=")">
<mml:mo>%</mml:mo>
</mml:mfenced>
</mml:math>
</disp-formula>
<p>The percent relative error between each POC meter result and the reference laboratory result was calculated with <xref ref-type="disp-formula" rid="EQ4">Equation 4</xref> for glucose and &#x03B2;-HB:</p>
<disp-formula id="EQ4">
<label>(4)</label>
<mml:math id="M4">
<mml:mi mathvariant="italic">Relative</mml:mi>
<mml:mspace width="0.25em"/>
<mml:mi mathvariant="italic">Error</mml:mi>
<mml:mspace width="0.25em"/>
<mml:mfenced open="(" close=")">
<mml:mo>%</mml:mo>
</mml:mfenced>
<mml:mo>=</mml:mo>
<mml:mfenced open="|" close="|">
<mml:mfrac>
<mml:mrow>
<mml:mi mathvariant="italic">Resul</mml:mi>
<mml:msub>
<mml:mi>t</mml:mi>
<mml:mrow>
<mml:mi>P</mml:mi>
<mml:mi>O</mml:mi>
<mml:mi>C</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:mi mathvariant="italic">Resul</mml:mi>
<mml:msub>
<mml:mi>t</mml:mi>
<mml:mi mathvariant="italic">Reference</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mrow>
<mml:mi mathvariant="italic">Resul</mml:mi>
<mml:msub>
<mml:mi>t</mml:mi>
<mml:mi mathvariant="italic">Reference</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mfrac>
</mml:mfenced>
<mml:mo>&#x00D7;</mml:mo>
<mml:mn>100</mml:mn>
</mml:math>
</disp-formula>
<p>The proportions of results with a percent relative error&#x2009;&#x003C;&#x2009;12, 15, and 20% were calculated for each POC meter for both glucose and &#x03B2;-HB using whole blood and plasma and compared to the US Food and Drug Administration relative error guidelines for human glucometers as previously described (<xref ref-type="bibr" rid="ref26">26</xref>). For Bland&#x2013;Altman plots and statistics, bias was calculated by subtracting the reference laboratory result from the POC meter result (<xref ref-type="bibr" rid="ref32">32</xref>). The mean bias and the limits of agreement (LoAs) were then calculated for each POC meter for both glucose and &#x03B2;-HB using whole blood and plasma (<xref ref-type="bibr" rid="ref32">32</xref>); LoAs were calculated with <xref ref-type="disp-formula" rid="EQ5">Equation 5</xref>:</p>
<disp-formula id="EQ5">
<label>(5)</label>
<mml:math id="M5">
<mml:mi>L</mml:mi>
<mml:mi>o</mml:mi>
<mml:mi>A</mml:mi>
<mml:mo>=</mml:mo>
<mml:mi>M</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>a</mml:mi>
<mml:msub>
<mml:mi>n</mml:mi>
<mml:mi mathvariant="italic">Difference</mml:mi>
</mml:msub>
<mml:mo>&#x00B1;</mml:mo>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mn>1.96</mml:mn>
<mml:mo>&#x00D7;</mml:mo>
<mml:mi mathvariant="italic">Standard</mml:mi>
<mml:mspace width="0.25em"/>
<mml:mi mathvariant="italic">Deviatio</mml:mi>
<mml:msub>
<mml:mi>n</mml:mi>
<mml:mi mathvariant="italic">Difference</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mfenced>
</mml:math>
</disp-formula>
<p>Bias was considered statistically significant if the mean bias&#x2019;s 95% confidence interval (95% CI) did not include 0 (<xref ref-type="bibr" rid="ref32">32</xref>). For Passing-Bablok regression, constant bias was present if the <italic>y</italic>-intercept&#x2019;s 95% CI did not include 0, whereas proportional bias was present if the slope&#x2019;s 95% CI did not include 1 (<xref ref-type="bibr" rid="ref33">33</xref>, <xref ref-type="bibr" rid="ref34">34</xref>).</p>
<p>To explore the effect of multiple variables on the difference between the POC meters and the reference laboratory analyzer, linear mixed-effect models were constructed for each POC meter for both glucose and &#x03B2;-HB. The difference between the POC meter and reference laboratory for either glucose and &#x03B2;-HB was included as the dependent variable; sex (male or female), weight, PCV, BC, and matrix (plasma or whole blood) were included as fixed effects; and stingray species and individual stingrays were included as random effects.</p>
<p>Data were collated in a standard spreadsheet software spreadsheet (Microsoft Excel, Microsoft Corporation, Redmond, WA, United States). All analyses were performed in the free statistical software R (v4.3.1, R Foundation for Statistical Computing, Vienna, Austria). <italic>p</italic> values &#x003C;0.05 were considered significant. Data organization and summary statistics were performed using the dplyr (v1.1.2) (<xref ref-type="bibr" rid="ref35">35</xref>) and psych (v2.3.6) (<xref ref-type="bibr" rid="ref36">36</xref>) packages and their dependents. Bland&#x2013;Altman plots and statistics were performed using the blandr (v0.5.3) (<xref ref-type="bibr" rid="ref36">36</xref>) and ggplot2 (v3.4.3) (<xref ref-type="bibr" rid="ref37">37</xref>) packages and their dependents. Passing-Bablok regression analyses were performed using the mcr package (v1.3.2) (<xref ref-type="bibr" rid="ref38">38</xref>) and its dependents. Linear mixed-effect models were constructed using the lmerTest (v3.1.3) (<xref ref-type="bibr" rid="ref39">39</xref>) package.</p>
</sec>
</sec>
<sec sec-type="results" id="sec7">
<label>3</label>
<title>Results</title>
<p>Plasma glucose and &#x03B2;-HB concentrations, as determined by the reference laboratory, ranged from &#x003C;20&#x2013;63 mg/dL (median: 35 mg/dL) and 0.05&#x2013;5.38 mmol/L (median: 0.22&#x2009;mmol/L, <xref ref-type="table" rid="tab1">Table 1</xref>), respectively. PCV, BC, and TS for all stingrays ranged from 11&#x2013;32% (median: 24%), 0&#x2013;4% (median: 0%), and 4.4&#x2013;8.1 g/dL (median: 7.0 g/dL). Glucose concentration ranges as determined by the reference laboratory were similar across species: &#x003C; 20&#x2013;53&#x2009;mg/dL (median: 26&#x2009;mg/dL) for Atlantic stingrays, 32&#x2013;59&#x2009;mg/dL (median: 48&#x2009;mg/dL) for cownose rays, 23&#x2013;39&#x2009;mg/dL (median: 36&#x2009;mg/dL) for southern stingrays, and&#x2009;&#x003C;&#x2009;20&#x2013;63&#x2009;mg/dL (median: 30&#x2009;mg/dL) for yellow stingrays. Similarly, &#x03B2;-HB concentration ranges as determined by the reference laboratory were similar across species: 0.1&#x2013;0.4&#x2009;mmol/L (median: 0.22&#x2009;mmol/L) for Atlantic stingrays, 0.08&#x2013;0.69&#x2009;mmol/L (median: 0.31&#x2009;mmol/L) for cownose rays, 0.14&#x2013;0.28&#x2009;mmol/L (median: 0.23&#x2009;mmol/L) for southern stingrays, and 0.05&#x2013;5.38&#x2009;mmol/L (median: 0.22&#x2009;mmol/L) for yellow stingrays with the maximum of the yellow stingray range being skewed by one individual (5.38&#x2009;mmol/L). With the one apparent yellow stingray outlier removed, the &#x03B2;-HB concentration range was 0.05&#x2013;0.52&#x2009;mmol/L for conspecifics included in this study.</p>
<table-wrap position="float" id="tab1">
<label>Table 1</label>
<caption>
<p>Summary statistics of whole blood (WB) and plasma (P) glucose and &#x03B2;-hydroxybutyrate (&#x03B2;-HB) concentrations in stingrays determined by three commercial point-of-care glucose and &#x03B2;-HB meters and reference laboratory methods.</p>
</caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th align="left" valign="top">Analyte</th>
<th align="left" valign="top">Analyzer</th>
<th align="left" valign="top">Matrix</th>
<th align="center" valign="top"><italic>n</italic></th>
<th align="center" valign="top">Mean</th>
<th align="center" valign="top">SD</th>
<th align="center" valign="top">Median</th>
<th align="center" valign="top">Min</th>
<th align="center" valign="top">Max</th>
</tr>
</thead>
<tbody>
<tr>
<td align="left" valign="middle" rowspan="7">Glucose (mg/dL)</td>
<td align="left" valign="middle">BHBCheck</td>
<td align="left" valign="middle">WB</td>
<td align="center" valign="middle">22</td>
<td align="center" valign="middle">79</td>
<td align="center" valign="middle">21</td>
<td align="center" valign="middle">79</td>
<td align="center" valign="middle">16</td>
<td align="center" valign="middle">119</td>
</tr>
<tr>
<td/>
<td align="left" valign="middle">P</td>
<td align="center" valign="middle">22</td>
<td align="center" valign="middle">99</td>
<td align="center" valign="middle">30</td>
<td align="center" valign="middle">99</td>
<td align="center" valign="middle">56</td>
<td align="center" valign="middle">154</td>
</tr>
<tr>
<td align="left" valign="middle">Precision Xtra</td>
<td align="left" valign="middle">WB</td>
<td align="center" valign="middle">28</td>
<td align="center" valign="middle">35</td>
<td align="center" valign="middle">20</td>
<td align="center" valign="middle">39</td>
<td align="center" valign="middle">&#x003C; 20</td>
<td align="center" valign="middle">71</td>
</tr>
<tr>
<td/>
<td align="left" valign="middle">P</td>
<td align="center" valign="middle">28</td>
<td align="center" valign="middle">44</td>
<td align="center" valign="middle">22</td>
<td align="center" valign="middle">45</td>
<td align="center" valign="middle">&#x003C; 20</td>
<td align="center" valign="middle">88</td>
</tr>
<tr>
<td align="left" valign="middle">Nova Vet&#x2122;</td>
<td align="left" valign="middle">WB</td>
<td align="center" valign="middle">28</td>
<td align="center" valign="middle">16</td>
<td align="center" valign="middle">11</td>
<td align="center" valign="middle">&#x003C; 20</td>
<td align="center" valign="middle">&#x003C; 20</td>
<td align="center" valign="middle">46</td>
</tr>
<tr>
<td/>
<td align="left" valign="middle">P</td>
<td align="center" valign="middle">28</td>
<td align="center" valign="middle">20</td>
<td align="center" valign="middle">15</td>
<td align="center" valign="middle">&#x003C; 20</td>
<td align="center" valign="middle">&#x003C; 20</td>
<td align="center" valign="middle">54</td>
</tr>
<tr>
<td align="left" valign="middle">Reference Lab</td>
<td align="left" valign="middle">P</td>
<td align="center" valign="middle">28</td>
<td align="center" valign="middle">34</td>
<td align="center" valign="middle">15</td>
<td align="center" valign="middle">35</td>
<td align="center" valign="middle">&#x003C; 20</td>
<td align="center" valign="middle">63</td>
</tr>
<tr>
<td align="left" valign="middle" rowspan="7">&#x03B2;-HB (mmol/L)</td>
<td align="left" valign="middle">BHBCheck</td>
<td align="left" valign="middle">WB</td>
<td align="center" valign="bottom">28</td>
<td align="center" valign="middle">0.7</td>
<td align="center" valign="middle">0.8</td>
<td align="center" valign="middle">0.6</td>
<td align="center" valign="middle">0.2</td>
<td align="center" valign="middle">4.4</td>
</tr>
<tr>
<td/>
<td align="left" valign="middle">P</td>
<td align="center" valign="bottom">28</td>
<td align="center" valign="middle">0.6</td>
<td align="center" valign="middle">0.9</td>
<td align="center" valign="middle">0.4</td>
<td align="center" valign="middle">0.1</td>
<td align="center" valign="middle">5.3</td>
</tr>
<tr>
<td align="left" valign="middle">Precision Xtra</td>
<td align="left" valign="middle">WB</td>
<td align="center" valign="bottom">28</td>
<td align="center" valign="middle">0.7</td>
<td align="center" valign="middle">0.9</td>
<td align="center" valign="middle">0.6</td>
<td align="center" valign="middle">0.1</td>
<td align="center" valign="middle">5.2</td>
</tr>
<tr>
<td/>
<td align="left" valign="middle">P</td>
<td align="center" valign="bottom">28</td>
<td align="center" valign="middle">0.5</td>
<td align="center" valign="middle">0.8</td>
<td align="center" valign="middle">0.3</td>
<td align="center" valign="middle">0</td>
<td align="center" valign="middle">4.3</td>
</tr>
<tr>
<td align="left" valign="middle">Nova Vet&#x2122;</td>
<td align="left" valign="middle">WB</td>
<td align="center" valign="bottom">28</td>
<td align="center" valign="middle">0.4</td>
<td align="center" valign="middle">0.5</td>
<td align="center" valign="middle">0.3</td>
<td align="center" valign="middle">&#x003C; 0.1</td>
<td align="center" valign="middle">2.9</td>
</tr>
<tr>
<td/>
<td align="left" valign="middle">P</td>
<td align="center" valign="bottom">28</td>
<td align="center" valign="middle">0.6</td>
<td align="center" valign="middle">0.5</td>
<td align="center" valign="middle">0.5</td>
<td align="center" valign="middle">0.2</td>
<td align="center" valign="middle">3.3</td>
</tr>
<tr>
<td align="left" valign="middle">Reference Lab</td>
<td align="left" valign="middle">P</td>
<td align="center" valign="bottom">28</td>
<td align="center" valign="middle">0.44</td>
<td align="center" valign="middle">0.98</td>
<td align="center" valign="middle">0.22</td>
<td align="center" valign="middle">0.05</td>
<td align="center" valign="middle">5.38</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<p>SD, Standard deviation; Min, Minimum; and Max, Maximum.</p>
</table-wrap-foot>
</table-wrap>
<p>The CV or imprecision of the three POC meters for glucose was less when using plasma (maximum: 0&#x2013;4.9%) than whole blood (maximum: 11%); similarly, the CV of the three POC meters for &#x03B2;-HB was less when using plasma (maximum: 0%) than whole blood (maximum: 12.5%). The CV was 0% for all three POC meters when measuring &#x03B2;-HB using plasma (<xref ref-type="table" rid="tab2">Table 2</xref>). All three POC meters had less TE<sub>obs</sub> for both whole blood and plasma when measuring &#x03B2;-HB than glucose (<xref ref-type="table" rid="tab2">Table 2</xref>). The proportions of results with percent relative error&#x2009;&#x003C;&#x2009;12, 15, and 20% were tabulated for each POC meter for glucose and &#x03B2;-HB using whole blood and plasma (<xref ref-type="table" rid="tab2">Table 2</xref>).</p>
<table-wrap position="float" id="tab2">
<label>Table 2</label>
<caption>
<p>Percent coefficient of variation (CV), bias, and observed total error (TE<sub>obs</sub>) for whole blood (WB) and plasma (P) glucose and &#x03B2;-hydroxybutyrate (&#x03B2;-HB) concentrations in stingrays determined by three commercial point-of-care glucose and &#x03B2;-HB meters.</p>
</caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th align="left" valign="top">Analyte</th>
<th align="left" valign="top">Analyzer</th>
<th align="left" valign="top">Matrix</th>
<th align="center" valign="top"><italic>n</italic></th>
<th align="center" valign="top">CV</th>
<th align="center" valign="top">Bias</th>
<th align="center" valign="top">TE<sub>obs</sub></th>
<th align="center" valign="top">&#x003C; 12% RE</th>
<th align="center" valign="top">&#x003C; 15% RE</th>
<th align="center" valign="top">&#x003C; 20% RE</th>
</tr>
</thead>
<tbody>
<tr>
<td align="left" valign="middle" rowspan="6">Glucose (%)</td>
<td align="left" valign="middle">BHBCheck</td>
<td align="left" valign="middle">WB</td>
<td align="center" valign="middle">22</td>
<td align="center" valign="middle">2.4</td>
<td align="center" valign="middle">3188.2</td>
<td align="center" valign="middle">3,193</td>
<td align="center" valign="middle">0</td>
<td align="center" valign="middle">0</td>
<td align="center" valign="middle">0</td>
</tr>
<tr>
<td/>
<td align="left" valign="middle">P</td>
<td align="center" valign="middle">22</td>
<td align="center" valign="middle">2.7</td>
<td align="center" valign="middle">3127.4</td>
<td align="center" valign="middle">3132.8</td>
<td align="center" valign="middle">0</td>
<td align="center" valign="middle">0</td>
<td align="center" valign="middle">0</td>
</tr>
<tr>
<td align="left" valign="middle">Precision Xtra</td>
<td align="left" valign="middle">WB</td>
<td align="center" valign="middle">28</td>
<td align="center" valign="middle">11</td>
<td align="center" valign="middle">3316.8</td>
<td align="center" valign="middle">3338.8</td>
<td align="center" valign="middle">46.4</td>
<td align="center" valign="middle">64.3</td>
<td align="center" valign="middle">71.4</td>
</tr>
<tr>
<td/>
<td align="left" valign="middle">P</td>
<td align="center" valign="middle">28</td>
<td align="center" valign="middle">4.9</td>
<td align="center" valign="middle">3289.1</td>
<td align="center" valign="middle">3298.9</td>
<td align="center" valign="middle">21.4</td>
<td align="center" valign="middle">21.4</td>
<td align="center" valign="middle">35.7</td>
</tr>
<tr>
<td align="left" valign="middle">Nova Vet&#x2122;</td>
<td align="left" valign="middle">WB</td>
<td align="center" valign="middle">28</td>
<td align="center" valign="middle">0</td>
<td align="center" valign="middle">3371.4</td>
<td align="center" valign="middle">3371.4</td>
<td align="center" valign="middle">17.9</td>
<td align="center" valign="middle">17.9</td>
<td align="center" valign="middle">21.4</td>
</tr>
<tr>
<td/>
<td align="left" valign="middle">P</td>
<td align="center" valign="middle">28</td>
<td align="center" valign="middle">0</td>
<td align="center" valign="middle">3359.1</td>
<td align="center" valign="middle">3359.1</td>
<td align="center" valign="middle">21.4</td>
<td align="center" valign="middle">25</td>
<td align="center" valign="middle">32.1</td>
</tr>
<tr>
<td align="left" valign="middle" rowspan="6">&#x03B2;-HB (%)</td>
<td align="left" valign="middle">BHBCheck</td>
<td align="left" valign="middle">WB</td>
<td align="center" valign="bottom">28</td>
<td align="center" valign="middle">12.4</td>
<td align="center" valign="middle">103</td>
<td align="center" valign="middle">127.8</td>
<td align="center" valign="middle">3.6</td>
<td align="center" valign="middle">3.6</td>
<td align="center" valign="middle">10.7</td>
</tr>
<tr>
<td/>
<td align="left" valign="middle">P</td>
<td align="center" valign="bottom">28</td>
<td align="center" valign="middle">0</td>
<td align="center" valign="middle">88.4</td>
<td align="center" valign="middle">88.4</td>
<td align="center" valign="middle">10.7</td>
<td align="center" valign="middle">10.7</td>
<td align="center" valign="middle">10.7</td>
</tr>
<tr>
<td align="left" valign="middle">Precision Xtra</td>
<td align="left" valign="middle">WB</td>
<td align="center" valign="bottom">28</td>
<td align="center" valign="middle">0</td>
<td align="center" valign="middle">103</td>
<td align="center" valign="middle">103</td>
<td align="center" valign="middle">14.3</td>
<td align="center" valign="middle">14.3</td>
<td align="center" valign="middle">14.3</td>
</tr>
<tr>
<td/>
<td align="left" valign="middle">P</td>
<td align="center" valign="bottom">28</td>
<td align="center" valign="middle">0</td>
<td align="center" valign="middle">65.8</td>
<td align="center" valign="middle">65.8</td>
<td align="center" valign="middle">10.7</td>
<td align="center" valign="middle">10.7</td>
<td align="center" valign="middle">21.4</td>
</tr>
<tr>
<td align="left" valign="middle">Nova Vet&#x2122;</td>
<td align="left" valign="middle">WB</td>
<td align="center" valign="bottom">28</td>
<td align="center" valign="middle">0</td>
<td align="center" valign="middle">37.9</td>
<td align="center" valign="middle">37.9</td>
<td align="center" valign="middle">10.7</td>
<td align="center" valign="middle">10.7</td>
<td align="center" valign="middle">21.4</td>
</tr>
<tr>
<td/>
<td align="left" valign="middle">P</td>
<td align="center" valign="bottom">28</td>
<td align="center" valign="middle">0</td>
<td align="center" valign="middle">80.3</td>
<td align="center" valign="middle">80.3</td>
<td align="center" valign="middle">10.7</td>
<td align="center" valign="middle">14.3</td>
<td align="center" valign="middle">21.4</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<p>The American Society for Veterinary Clinical Pathology guidelines advise TE<sub>obs</sub> be &#x003C;20% for point-of-care measurements within and above the reference interval. The percentages of measurements with percent relative error (RE)&#x2009;&#x003C;&#x2009;12, 15, and 20% are reported for each point-of-care meter, analyte, and matrix. The US Food and Drug Administration requires 95 and 98% of measurements to be within 12 and 15% of reference concentrations for glucometers intended for professional human healthcare use and 96 and 100% of measurements to be within 15 and 20% of reference concentrations for glucometers intended for over-the-counter use in human patients.</p>
</table-wrap-foot>
</table-wrap>
<p>Bland&#x2013;Altman methods found the BHBCheck meter had significant positive bias (i.e., overestimated) for both glucose and &#x03B2;-HB regardless of the matrix (<xref ref-type="table" rid="tab3">Table 3</xref>; <xref ref-type="fig" rid="fig1">Figures 1</xref>, <xref ref-type="fig" rid="fig2">2</xref>). The Precision Xtra meter had a significant positive bias for glucose using plasma and &#x03B2;-HB using whole blood (<xref ref-type="table" rid="tab3">Table 3</xref>; <xref ref-type="fig" rid="fig1">Figures 1</xref>, <xref ref-type="fig" rid="fig2">2</xref>). The Nova Vet&#x2122; had significant negative bias (i.e., underestimated) for glucose regardless of the matrix (<xref ref-type="table" rid="tab3">Table 3</xref>; <xref ref-type="fig" rid="fig1">Figures 1</xref>, <xref ref-type="fig" rid="fig2">2</xref>). For glucose, the mean bias ranged from &#x2212;18 to 48&#x2009;mg/dL using whole blood and from &#x2212;14 to 69&#x2009;mg/dL using plasma across the three POC meters (<xref ref-type="table" rid="tab3">Table 3</xref>). For &#x03B2;-HB, the mean bias ranged from &#x2212;0.1 to 0.2&#x2009;mmol/L using whole blood and from 0 to 0.1&#x2009;mmol/L using plasma across the three POC meters (<xref ref-type="table" rid="tab3">Table 3</xref>).</p>
<table-wrap position="float" id="tab3">
<label>Table 3</label>
<caption>
<p>Bland&#x2013;Altman statistics and Passing-Bablok regression results for whole blood (WB) and plasma (P) glucose and &#x03B2;-hydroxybutyrate (&#x03B2;-HB) concentrations in stingrays determined by three commercial point-of-care glucose and &#x03B2;-HB meters and reference laboratory methods.</p>
</caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th/>
<th/>
<th/>
<th align="center" valign="top" colspan="3">Bland&#x2013;Altman statistics</th>
<th align="center" valign="top" colspan="2">Passing-Bablok regression</th>
</tr>
<tr>
<th align="left" valign="middle">Analyte</th>
<th align="left" valign="middle">Analyzer</th>
<th align="left" valign="middle">Matrix</th>
<th align="center" valign="middle">Bias</th>
<th align="center" valign="middle">Lower LoA</th>
<th align="center" valign="middle">Upper LoA</th>
<th align="center" valign="middle">Intercept</th>
<th align="center" valign="middle">Slope</th>
</tr>
</thead>
<tbody>
<tr>
<td align="left" valign="middle" rowspan="6">Glucose (mg/dL)</td>
<td align="left" valign="middle">BHBCheck</td>
<td align="left" valign="middle">WB</td>
<td align="center" valign="middle">48 (41, 56)<sup>&#x002A;</sup></td>
<td align="center" valign="middle">15 (2, 28)</td>
<td align="center" valign="middle">81 (68, 94)</td>
<td align="center" valign="bottom">37 (3, 55)<sup>&#x002A;</sup></td>
<td align="center" valign="bottom">1.4 (0.9, 2.4)</td>
</tr>
<tr>
<td/>
<td align="left" valign="middle">P</td>
<td align="center" valign="middle">69 (61, 78)<sup>&#x002A;</sup></td>
<td align="center" valign="middle">31 (17, 46)</td>
<td align="center" valign="middle">107 (92, 121)</td>
<td align="center" valign="bottom">29 (8, 46)<sup>&#x002A;</sup></td>
<td align="center" valign="bottom">2.3 (1.9, 2.8)<sup>&#x002A;</sup></td>
</tr>
<tr>
<td align="left" valign="middle">Precision Xtra</td>
<td align="left" valign="middle">WB</td>
<td align="center" valign="middle">0 (&#x2212;3, 4)</td>
<td align="center" valign="middle">&#x2212;17 (&#x2212;23, &#x2212;11)</td>
<td align="center" valign="middle">18 (12, 24)</td>
<td align="center" valign="bottom">&#x2212;6 (&#x2212;21, &#x2212;1)<sup>&#x002A;</sup></td>
<td align="center" valign="bottom">1.3 (1.1, 1.6)<sup>&#x002A;</sup></td>
</tr>
<tr>
<td/>
<td align="left" valign="middle">P</td>
<td align="center" valign="middle">10 (6, 14)<sup>&#x002A;</sup></td>
<td align="center" valign="middle">&#x2212;10 (&#x2212;17, &#x2212;3)</td>
<td align="center" valign="middle">29 (23, 36)</td>
<td align="center" valign="bottom">&#x2212;5 (&#x2212;15, 1)</td>
<td align="center" valign="bottom">1.4 (1.3, 1.7)<sup>&#x002A;</sup></td>
</tr>
<tr>
<td align="left" valign="middle">Nova Vet&#x2122;</td>
<td align="left" valign="middle">WB</td>
<td align="center" valign="middle">&#x2212;18 (&#x2212;23, &#x2212;14)<sup>&#x002A;</sup></td>
<td align="center" valign="middle">&#x2212;40 (&#x2212;47, &#x2212;32)</td>
<td align="center" valign="middle">3 (&#x2212;4, 10)</td>
<td align="center" valign="bottom">10 (&#x2212;7, 10)</td>
<td align="center" valign="bottom">0 (0, 0.6)<sup>&#x002A;</sup></td>
</tr>
<tr>
<td/>
<td align="left" valign="middle">P</td>
<td align="center" valign="middle">&#x2212;14 (&#x2212;18, &#x2212;10)<sup>&#x002A;</sup></td>
<td align="center" valign="middle">&#x2212;33 (&#x2212;39, &#x2212;27)</td>
<td align="center" valign="middle">5 (&#x2212;2, 11)</td>
<td align="center" valign="middle">&#x2212;5 (&#x2212;20, 10)</td>
<td align="center" valign="middle">0.7 (0, 1.1)</td>
</tr>
<tr>
<td align="left" valign="middle" rowspan="6">&#x03B2;-HB (mmol/L)</td>
<td align="left" valign="middle">BHBCheck</td>
<td align="left" valign="middle">WB</td>
<td align="center" valign="middle">0.2 (0.1, 0.3)<sup>&#x002A;</sup></td>
<td align="center" valign="middle">&#x2212;0.3 (&#x2212;0.5, &#x2212;0.1)</td>
<td align="center" valign="middle">0.8 (0.6, 1)</td>
<td align="center" valign="bottom">0.2 (0, 0.3)</td>
<td align="center" valign="bottom">1.3 (0.9, 2.5)</td>
</tr>
<tr>
<td/>
<td align="left" valign="middle">P</td>
<td align="center" valign="middle">0.1 (0.1, 0.2)<sup>&#x002A;</sup></td>
<td align="center" valign="middle">&#x2212;0.1 (&#x2212;0.1, 0)</td>
<td align="center" valign="middle">0.4 (0.3, 0.4)</td>
<td align="center" valign="bottom">0.1 (0.1, 0.2)<sup>&#x002A;</sup></td>
<td align="center" valign="bottom">1.1 (1, 1.4)</td>
</tr>
<tr>
<td align="left" valign="middle">Precision Xtra</td>
<td align="left" valign="middle">WB</td>
<td align="center" valign="middle">0.2 (0.1, 0.3)<sup>&#x002A;</sup></td>
<td align="center" valign="middle">&#x2212;0.2 (&#x2212;0.3, &#x2212;0.1)</td>
<td align="center" valign="middle">0.6 (0.5, 0.8)</td>
<td align="center" valign="bottom">0 (&#x2212;0.2, 0.1)</td>
<td align="center" valign="bottom">2 (1.5, 2.7)<sup>&#x002A;</sup></td>
</tr>
<tr>
<td/>
<td align="left" valign="middle">P</td>
<td align="center" valign="middle">0 (&#x2212;0.1, 0.2)</td>
<td align="center" valign="middle">&#x2212;0.5 (&#x2212;0.7, &#x2212;0.3)</td>
<td align="center" valign="middle">0.6 (0.4, 0.8)</td>
<td align="center" valign="bottom">&#x2212;0.1 (&#x2212;0.2, 0)</td>
<td align="center" valign="bottom">1.7 (1.3, 2.2)<sup>&#x002A;</sup></td>
</tr>
<tr>
<td align="left" valign="middle">Nova Vet&#x2122;</td>
<td align="left" valign="middle">WB</td>
<td align="center" valign="middle">&#x2212;0.1 (&#x2212;0.3, 0.1)</td>
<td align="center" valign="middle">&#x2212;1.1 (&#x2212;1.4, &#x2212;0.7)</td>
<td align="center" valign="middle">1 (0.6, 1.3)</td>
<td align="center" valign="bottom">0 (&#x2212;0.2, 0.7)</td>
<td align="center" valign="bottom">1.1 (&#x2212;2.2, 1.8)</td>
</tr>
<tr>
<td/>
<td align="left" valign="middle">P</td>
<td align="center" valign="middle">0.1 (&#x2212;0.1, 0.3)</td>
<td align="center" valign="middle">&#x2212;0.8 (&#x2212;1.1, &#x2212;0.5)</td>
<td align="center" valign="middle">1 (0.7, 1.3)</td>
<td align="center" valign="middle">0.5 (0.3, 0.6)<sup>&#x002A;</sup></td>
<td align="center" valign="middle">0 (&#x2212;0.4, 0.6)<sup>&#x002A;</sup></td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<p>The mean difference (Bias) and the limits of agreement (LoA)&#x2014;defined as the mean difference&#x2009;&#x00B1;&#x2009;1.96 times the standard deviation of the differences&#x2014;were calculated for each meter. Bias was considered statistically significant (<sup>&#x002A;</sup>) if the mean difference&#x2019;s 95% confidence interval (95% CI) did not include 0. For Passing-Bablok regression, constant bias was present (<sup>&#x002A;</sup>) if the 95% CI for the <italic>y</italic>-intercept did not include 0, whereas proportional bias was present (<sup>&#x002A;</sup>) if the 95% CI for the slope did not include 1.</p>
</table-wrap-foot>
</table-wrap>
<fig position="float" id="fig1">
<label>Figure 1</label>
<caption>
<p>Bland&#x2013;Altman plots of whole blood <bold>(A, C, E)</bold> and plasma <bold>(B, D, F)</bold> glucose concentrations in stingrays determined by three commercial point-of-care meters compared to reference laboratory methods. Black dots represent individual stingrays. The mean difference (Bias, solid black line) and the limits of agreement (LoA, black dot-dashed lines)&#x2014;defined as the mean difference&#x2009;&#x00B1;&#x2009;1.96 times the standard deviation of the differences&#x2014;were calculated for each meter. Bias was considered statistically significant if the 95% confidence interval (red dashed lines) mean difference did not include 0.</p>
</caption>
<graphic xlink:href="fvets-10-1254340-g001.tif"/>
</fig>
<fig position="float" id="fig2">
<label>Figure 2</label>
<caption>
<p>Bland&#x2013;Altman plots of whole blood <bold>(A, C, E)</bold> and plasma <bold>(B, D, F)</bold> &#x03B2;-hydroxybutyrate (&#x03B2;-HB) concentrations in stingrays determined by three commercial point-of-care meters compared to reference laboratory methods. Black dots represent individual stingrays. The mean difference (Bias, solid black line) and the limits of agreement (LoA, black dot-dashed lines)&#x2014;defined as the mean difference&#x2009;&#x00B1;&#x2009;1.96 times, the standard deviation of the differences&#x2014;were calculated for each meter. Bias was considered statistically significant if the 95% confidence interval (red dashed lines) of the mean difference did not include 0. To avoid skewing the Bland&#x2013;Altman plots, a single yellow stingray outlier was removed (&#x03B2;-HB&#x2009;=&#x2009;5.38&#x2009;mmol/L via the reference laboratory method).</p>
</caption>
<graphic xlink:href="fvets-10-1254340-g002.tif"/>
</fig>
<p>Passing-Bablok regression analyses found that the BHBCheck meter had a significant constant bias for glucose regardless of matrix and &#x03B2;-HB using plasma and a significant proportional bias for glucose using plasma (<xref ref-type="table" rid="tab3">Table 3</xref>; <xref ref-type="fig" rid="fig3">Figures 3</xref>, <xref ref-type="fig" rid="fig4">4</xref>). The Precision Xtra meter had a significant constant bias for glucose using whole blood and &#x03B2;-HB using plasma, as well as a significant proportional bias for both glucose and &#x03B2;-HB regardless of the matrix (<xref ref-type="table" rid="tab3">Table 3</xref>; <xref ref-type="fig" rid="fig3">Figures 3</xref>, <xref ref-type="fig" rid="fig4">4</xref>). The Nova Vet&#x2122; meter had a significant constant bias for &#x03B2;-HB using plasma and a significant proportional bias for glucose using whole blood and &#x03B2;-HB using plasma (<xref ref-type="table" rid="tab3">Table 3</xref>; <xref ref-type="fig" rid="fig3">Figures 3</xref>, <xref ref-type="fig" rid="fig4">4</xref>).</p>
<fig position="float" id="fig3">
<label>Figure 3</label>
<caption>
<p>Passing-Bablok plots of whole blood and plasma glucose concentrations in stingrays determined by three commercial point-of-care meters compared to reference laboratory methods. Black dots represent individual stingrays. The solid blue line and associated shading represent the estimated regression line and its 95% confidence interval. For Passing-Bablok regression, constant bias was present if the 95% CI for the <italic>y</italic>-intercept did not include 0, whereas proportional bias was present if the 95% CI for the slope did not include 1.</p>
</caption>
<graphic xlink:href="fvets-10-1254340-g003.tif"/>
</fig>
<fig position="float" id="fig4">
<label>Figure 4</label>
<caption>
<p>Passing-Bablok plots of whole blood and plasma &#x03B2;-hydroxybutyrate (&#x03B2;-HB) concentrations in stingrays determined by three commercial point-of-care meters compared to reference laboratory methods. Black dots represent individual stingrays. The solid blue line and associated shading represent the estimated regression line and its 95% confidence interval. For Passing-Bablok regression, constant bias was present if the 95% CI for the <italic>y</italic>-intercept did not include 0, whereas proportional bias was present if the 95% CI for the slope did not include 1. To avoid skewing the Passing-Bablok plots, a single yellow stingray outlier was removed (&#x03B2;-HB&#x2009;=&#x2009;5.38&#x2009;mmol/L via the reference laboratory method).</p>
</caption>
<graphic xlink:href="fvets-10-1254340-g004.tif"/>
</fig>
<p>Linear mixed-effect models found sex, weight, PCV, and BC had no significant effect on differences between the individual POC meters and the reference laboratory for glucose or &#x03B2;-HB. Matrix had no significant effect on differences between the BHBCheck or Nova Vet&#x2122; meters and the reference laboratory methods for glucose or &#x03B2;-HB. However, matrix did have a significant effect on &#x03B2;-HB, but not glucose, for the Precision Xtra meter: differences in &#x03B2;-HB concentrations were significantly lower using whole blood than plasma (matrix estimate&#x2009;&#x00B1;&#x2009;standard error: &#x2212;2.3&#x2009;&#x00B1;&#x2009;0.71&#x2009;mmol/L, <italic>p</italic> value&#x2009;=&#x2009;0.002).</p>
</sec>
<sec sec-type="discussion" id="sec8">
<label>4</label>
<title>Discussion</title>
<p>This study evaluated the diagnostic agreement (i.e., accuracy) between three commercial POC glucose and &#x03B2;-HB meters to reference laboratory methods using whole blood and plasma from four stingray species commonly found in managed care environments. Plasma glucose concentrations determined by a reference laboratory method were similar to previous reports in cownose rays and southern stingrays (<xref ref-type="bibr" rid="ref40 ref41 ref42">40&#x2013;42</xref>); likewise, &#x03B2;-HB concentrations determined by a reference laboratory method fell within previously reported ranges in elasmobranchs (<xref ref-type="bibr" rid="ref4">4</xref>). Of the three POC meters evaluated, the Precision Xtra&#x2014;a human-licensed glucometer&#x2014;showed the greatest agreement with the reference laboratory methods when measuring glucose from whole blood (mean bias: 0&#x2009;mg/dL) and measuring &#x03B2;-HB from plasma (mean bias: 0.1&#x2009;mmol/L) in stingrays. Stingray sex, weight, PCV, and BC did not significantly affect differences between the POC meters and the reference laboratory results. All three POC meters had better precision (i.e., intra-assay variability or repeatability) when using plasma than whole blood to measure glucose. Regarding the study&#x2019;s hypothesis, the mean bias and CV for plasma &#x03B2;-HB concentrations was relatively small (min-max: 0&#x2013;0.1&#x2009;mmol/L and 0%, respectively) across all three POC meters, suggesting POC &#x03B2;-HB measurement may have sufficient agreement with reference laboratory methods and precision for clinical and field research purposes.</p>
<p>The American Society for Veterinary Clinical Pathology (ASVCP) has developed guidelines for quality assurance and control of POC glucose measurement in light of the rising number of commercially available POC glucometers (<xref ref-type="bibr" rid="ref43">43</xref>). Point-of-care meter error can be categorized as pre-analytical, analytical, and post-analytical (<xref ref-type="bibr" rid="ref43">43</xref>). Pre-analytical error was minimized in the present study by adequate observer training and using similar sampling techniques and venipuncture sites. However, species- or individual-specific matrix properties (e.g., blood viscosity, rheology, mean corpuscular volume, etc.) may have contributed to error between the three POC meters and the reference laboratory analyzer, particularly for glucose concentrations. The distribution of glucose between RBCs and plasma is an important matrix-related variable across species (<xref ref-type="bibr" rid="ref43">43</xref>). Glucose is distributed equally between RBCs and plasma in humans, whereas in canine, feline, rabbit, and avian patients, glucose in circulation is found predominantly in plasma (<xref ref-type="bibr" rid="ref43">43</xref>). To the authors&#x2019; knowledge, the distribution of glucose between RBCs and plasma in the four stingray species sampled is unknown and remains a potential avenue of future physiologic research. Analytical error was minimized during data collection by using test strips before they expired, routine calibration using manufacturer-provided control materials, and not operating the POC meters under extreme environmental conditions. Post-analytical error was avoided by using consistent units of measurement (mg/dL for glucose, mmol/L for &#x03B2;-HB) and recording results immediately after being displayed by the POC meters.</p>
<p>In human and veterinary patients, anemia or hemoconcentration can falsely increase or decrease POC meter glucose or &#x03B2;-HB measurements (<xref ref-type="bibr" rid="ref15">15</xref>, <xref ref-type="bibr" rid="ref18">18</xref>, <xref ref-type="bibr" rid="ref21">21</xref>, <xref ref-type="bibr" rid="ref43">43</xref>, <xref ref-type="bibr" rid="ref44">44</xref>). In stingrays, linear mixed-effect models found PCV had no significant effect on differences between the three POC meters and the reference laboratory analyzer, despite a subset of sampled stingrays with PCV values lower than the recommended ranges for the meter. Possible reasons PCV influences POC meter glucose or &#x03B2;-HB measurements include built-in conversion factors or increased diffusion rate in test strips with lower PCV (<xref ref-type="bibr" rid="ref43">43</xref>). This study did not assess whether analytical interference occurred due to other blood gas or biochemical parameters such as pH, pO<sub>2</sub>, cholesterol, bilirubin, or biliverdin (<xref ref-type="bibr" rid="ref43">43</xref>). All sampled stingrays were anesthetized with MS-222 to ensure safe and efficient handling, which could have resulted in analytical interference secondary to perianesthetic physiologic changes (e.g., acid&#x2013;base status, body temperature, ventilation, vasoconstriction, etc.). Although veterinary studies are lacking, POC glucometers are less accurate intraoperatively in human patients under anesthesia (<xref ref-type="bibr" rid="ref45">45</xref>, <xref ref-type="bibr" rid="ref46">46</xref>).</p>
<p>The ASVCP guidelines advise TE<sub>obs</sub> for laboratory instruments, including POC glucose and &#x03B2;-HB meters, to be &#x003C;10% for values below the reference interval or&#x2009;&#x003C;&#x2009;20% for values within and above the reference interval (<xref ref-type="bibr" rid="ref43">43</xref>, <xref ref-type="bibr" rid="ref47">47</xref>). All three POC meters for both glucose and &#x03B2;-HB using whole blood and plasma had TE<sub>obs</sub>&#x2009;&#x003E;&#x2009;20%, indicative of undesirable analytical performance. Furthermore, the US Food and Drug Administration requires 95 and 98% of measurements to be within 12 and 15% of reference concentrations for POC glucometers intended for professional healthcare use and 96 and 100% of measurements to be within 15 and 20% of reference concentrations for POC glucometers intended for over-the-counter use (<xref ref-type="bibr" rid="ref26">26</xref>). All three POC meters evaluated did not meet US Food and Drug Administration relative error guidelines for human glucometers when measuring whole blood or plasma glucose concentrations in stingrays (<xref ref-type="bibr" rid="ref27">27</xref>). To the authors&#x2019; knowledge, neither the US Food and Drug Administration nor ASVCP has produced guidelines for POC &#x03B2;-HB meters despite their frequent use in monitoring diabetes mellitus in humans and domestic small animals.</p>
<p>Regardless of specific statistical analyses employed to compare new and established diagnostic methods, it is essential to appraise the clinical relevance of their analytic agreement. Clarke or Parkes Error Grid Analysis has historically been used in human and veterinary POC glucometer research to understand better potential clinical outcomes associated with POC meter accuracy (<xref ref-type="bibr" rid="ref48">48</xref>, <xref ref-type="bibr" rid="ref49">49</xref>). This study implemented neither method due to the wide range of glucose and &#x03B2;-HB concentrations observed in elasmobranchs and little consensus on pathophysiologic thresholds for either analyte (e.g., hypoglycemic, ketonemia). However, the BHBCheck meter could potentially lead to highly inaccurate glucose interpretations due to the magnitude of its mean bias using whole blood (48&#x2009;mg/dL) or plasma (69&#x2009;mg/dL) and the narrow range of glucose concentrations observed by the reference laboratory (&#x003C; 20&#x2013;63&#x2009;mg/dL). Passing-Bablok regression analyses found that all three POC meters mainly exhibited significant positive proportional bias (i.e., 95% CI&#x2009;&#x003E;&#x2009;1) measuring glucose and &#x03B2;-HB, signifying greater error at higher concentrations. Consequently, future research should assess agreement with a reference laboratory under potential pathophysiologic states or physiologic extremes (e.g., hyperglycemia secondary to long-line capture, ketonemia due to prolonged fasting, etc.).</p>
<p>Limitations of the present study include limited sample sizes per species (<italic>n</italic>&#x2009;&#x003C;&#x2009;10) and variable fasting durations before sampling, given differences in husbandry routines at the separate facilities. While imputation by substituting values below the LLOQ with a constant was employed in the present study, multiple imputation, maximum likelihood estimation, or kernel density estimation may be better alternative approaches. Although variation in venipuncture sites can influence PCV in sharks (<xref ref-type="bibr" rid="ref50">50</xref>) and downstream biochemical analyses in other taxa, no statistically significant differences between venipuncture sites were found in southern stingrays (<xref ref-type="bibr" rid="ref51">51</xref>). Although plasma was separated from RBCs promptly via centrifugation, glucose and &#x03B2;-HB concentrations could have decreased slightly between venipuncture and processing due to metabolism by cellular constituents.</p>
<p>Rapid, reliable detection of hyperglycemia due to physiologic stress could help veterinarians and researchers working with elasmobranchs more objectively monitor their welfare during capture, handling, and transport. Similarly, accurate POC measurement of &#x03B2;-HB could provide almost instant, cost-effective insight into the metabolic state of the elasmobranch patient vs. the turnaround time and expense of sending a sample to a reference laboratory. Further research should investigate POC meter clinical utility under different metabolic states in elasmobranchs. Using POC meters to measure glucose and &#x03B2;-HB concentrations in stingrays may be possible when reference methods are inaccessible. &#x03B2;-HB measurement using plasma will likely have sufficient accuracy and precision for clinical and field research purposes for the three POC meters evaluated in this study, especially the human-licensed glucometer, Precision Xtra.</p>
</sec>
<sec sec-type="data-availability" id="sec9">
<title>Data availability statement</title>
<p>The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.</p>
</sec>
<sec sec-type="ethics-statement" id="sec10">
<title>Ethics statement</title>
<p>The animal study was approved by North Carolina State University Institutional Animal Care and Use Committee. The study was conducted in accordance with the local legislation and institutional requirements.</p>
</sec>
<sec sec-type="author-contributions" id="sec11">
<title>Author contributions</title>
<p>ND: Conceptualization, Investigation, Data Curation, Formal analysis, Writing &#x2013; original draft, Writing &#x2013; review &#x0026; editing. CC: Writing &#x2013; review &#x0026; editing. LW: Writing &#x2013; review &#x0026; editing. EC: Writing &#x2013; review &#x0026; editing.</p>
</sec>
</body>
<back>
<sec sec-type="funding-information" id="sec12">
<title>Funding</title>
<p>The NC State College of Veterinary Medicine Support Fund for Aquatic Animal Medicine provided funding for this study.</p>
</sec>
<ack>
<p>The authors thank Craig Harms, Maria Serrano, Heather Broadhurst, Megan Cabot, Caitlin Hepps Keeney, Ashley Souza, Christian Capobianco, Kaitlynn Hicks, the animal care staff of the North Carolina Aquariums, and the staff of the University Miami Avian &#x0026; Wildlife Laboratory for their support and assistance with data collection.</p>
</ack>
<sec sec-type="COI-statement" id="sec13">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec id="sec100" sec-type="disclaimer">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ref-list>
<title>References</title>
<ref id="ref1"><label>1.</label><citation citation-type="book"><person-group person-group-type="author"><name><surname>Aschliman</surname><given-names>NC</given-names></name> <name><surname>Claeson</surname><given-names>KM</given-names></name> <name><surname>McEachran</surname><given-names>JD</given-names></name></person-group>. <article-title>Phylogeny of Batoidea</article-title> In: <person-group person-group-type="editor"><name><surname>Carrier</surname> <given-names>JC</given-names></name> <name><surname>Musick</surname> <given-names>JA</given-names></name> <name><surname>Heithaus</surname> <given-names>MR</given-names></name></person-group>, editors. <source>Biology of Sharks and Their Relatives</source>. <edition>2nd</edition> ed. <publisher-loc>Boca Raton</publisher-loc>: <publisher-name>CRC Press</publisher-name> (<year>2012</year>)</citation></ref>
<ref id="ref2"><label>2.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dulvy</surname><given-names>NK</given-names></name> <name><surname>Pacoureau</surname><given-names>N</given-names></name> <name><surname>Rigby</surname><given-names>CL</given-names></name> <name><surname>Pollom</surname><given-names>RA</given-names></name> <name><surname>Jabado</surname><given-names>RW</given-names></name> <name><surname>Ebert</surname><given-names>DA</given-names></name> <etal/></person-group>. <article-title>Overfishing drives over one-third of all sharks and rays toward a global extinction crisis</article-title>. <source>Curr Biol</source>. (<year>2021</year>) <volume>31</volume>:<fpage>4773</fpage>&#x2013;<lpage>4787.e8</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.cub.2021.08.062</pub-id>, PMID: <pub-id pub-id-type="pmid">34492229</pub-id></citation></ref>
<ref id="ref3"><label>3.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ballantyne</surname><given-names>JS</given-names></name></person-group>. <article-title>Jaws: the inside story. The metabolism of elasmobranch fishes</article-title>. <source>Comp Biochem Physiol B Biochem Mol Biol</source>. (<year>1997</year>) <volume>118</volume>:<fpage>703</fpage>&#x2013;<lpage>42</lpage>. doi: <pub-id pub-id-type="doi">10.1016/S0305-0491(97)00272-1</pub-id></citation></ref>
<ref id="ref4"><label>4.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Speers-Roesch</surname><given-names>B</given-names></name> <name><surname>Treberg</surname><given-names>JR</given-names></name></person-group>. <article-title>The unusual energy metabolism of elasmobranch fishes</article-title>. <source>Comp Biochem Physiol A Mol Integr Physiol</source>. (<year>2010</year>) <volume>155</volume>:<fpage>417</fpage>&#x2013;<lpage>34</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.cbpa.2009.09.031</pub-id>, PMID: <pub-id pub-id-type="pmid">19822221</pub-id></citation></ref>
<ref id="ref5"><label>5.</label><citation citation-type="book"><person-group person-group-type="author"><name><surname>Ballantyne</surname><given-names>JS</given-names></name></person-group>. <article-title>Metabolism of elasmobranchs (Jaws II)</article-title> In: <person-group person-group-type="editor"><name><surname>Shadwick</surname> <given-names>RE</given-names></name> <name><surname>Farrell</surname> <given-names>AP</given-names></name> <name><surname>Brauner</surname> <given-names>CJ</given-names></name></person-group>, editors. <source>Fish Physiology</source>, vol. <volume>34</volume>. <publisher-loc>Cambridge, MA</publisher-loc>: <publisher-name>Academic Press</publisher-name> (<year>2015</year>). <fpage>395</fpage>&#x2013;<lpage>456</lpage>.</citation></ref>
<ref id="ref6"><label>6.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wood</surname><given-names>CM</given-names></name> <name><surname>Walsh</surname><given-names>PJ</given-names></name> <name><surname>Kajimura</surname><given-names>M</given-names></name> <name><surname>McClelland</surname><given-names>GB</given-names></name> <name><surname>Chew</surname><given-names>SF</given-names></name></person-group>. <article-title>The influence of feeding and fasting on plasma metabolites in the dogfish shark (<italic>Squalus Acanthias</italic>)</article-title>. <source>Comp Biochem Physiol A Mol Integr Physiol</source>. (<year>2010</year>) <volume>155</volume>:<fpage>435</fpage>&#x2013;<lpage>44</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.cbpa.2009.09.006</pub-id>, PMID: <pub-id pub-id-type="pmid">19782147</pub-id></citation></ref>
<ref id="ref7"><label>7.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Walsh</surname><given-names>PJ</given-names></name> <name><surname>Kajimura</surname><given-names>M</given-names></name> <name><surname>Mommsen</surname><given-names>TP</given-names></name> <name><surname>Wood</surname><given-names>CM</given-names></name></person-group>. <article-title>Metabolic organization and effects of feeding on enzyme activities of the dogfish shark (<italic>Squalus Acanthias</italic>) rectal gland</article-title>. <source>J Exp Biol</source>. (<year>2006</year>) <volume>209</volume>:<fpage>2929</fpage>&#x2013;<lpage>38</lpage>. doi: <pub-id pub-id-type="doi">10.1242/jeb.02329</pub-id>, PMID: <pub-id pub-id-type="pmid">16857877</pub-id></citation></ref>
<ref id="ref8"><label>8.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Deck</surname><given-names>CA</given-names></name> <name><surname>Anderson</surname><given-names>WG</given-names></name> <name><surname>Conlon</surname><given-names>JM</given-names></name> <name><surname>Walsh</surname><given-names>PJ</given-names></name></person-group>. <article-title>The activity of the rectal gland of the North Pacific spiny dogfish <italic>Squalus Suckleyi</italic> is glucose dependent and stimulated by glucagon-like Peptide-1</article-title>. <source>J Comp Physiol B</source>. (<year>2017</year>) <volume>187</volume>:<fpage>1155</fpage>&#x2013;<lpage>61</lpage>. doi: <pub-id pub-id-type="doi">10.1007/s00360-017-1102-9</pub-id>, PMID: <pub-id pub-id-type="pmid">28444441</pub-id></citation></ref>
<ref id="ref9"><label>9.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bouyoucos</surname><given-names>IA</given-names></name> <name><surname>Schoen</surname><given-names>AN</given-names></name> <name><surname>Wahl</surname><given-names>RC</given-names></name> <name><surname>Anderson</surname><given-names>WG</given-names></name></person-group>. <article-title>Ancient fishes and the functional evolution of the corticosteroid stress response in vertebrates</article-title>. <source>Comp Biochem Physiol A Mol Integr Physiol</source>. (<year>2021</year>) <volume>260</volume>:<fpage>111024</fpage>. doi: <pub-id pub-id-type="doi">10.1016/j.cbpa.2021.111024</pub-id></citation></ref>
<ref id="ref10"><label>10.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Harding</surname><given-names>L</given-names></name> <name><surname>Gallagher</surname><given-names>A</given-names></name> <name><surname>Jackson</surname><given-names>A</given-names></name> <name><surname>Bortoluzzi</surname><given-names>J</given-names></name> <name><surname>Dolton</surname><given-names>HR</given-names></name> <name><surname>Shea</surname><given-names>B</given-names></name> <etal/></person-group>. <article-title>Capture heats up sharks</article-title>. <source>Conserv Physiol</source>. (<year>2022</year>) <volume>10</volume>:<fpage>coac065</fpage>. doi: <pub-id pub-id-type="doi">10.1093/conphys/coac065</pub-id></citation></ref>
<ref id="ref11"><label>11.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Cliff</surname><given-names>G</given-names></name> <name><surname>Thurman</surname><given-names>GD</given-names></name></person-group>. <article-title>Pathological and physiological effects of stress during capture and transport in the juvenile dusky shark, <italic>Carcharhinus Obscurus</italic></article-title>. <source>Comp Biochem Physiol A Mol Integr Physiol</source>. (<year>1984</year>) <volume>78</volume>:<fpage>167</fpage>&#x2013;<lpage>73</lpage>. doi: <pub-id pub-id-type="doi">10.1016/0300-9629(84)90111-7</pub-id></citation></ref>
<ref id="ref12"><label>12.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hoffmayer</surname><given-names>ER</given-names></name> <name><surname>Parsons</surname><given-names>GR</given-names></name></person-group>. <article-title>The physiological response to capture and handling stress in the Atlantic sharpnose shark <italic>Rhizoprionodon terraenovae</italic></article-title>. <source>Fish Physiol Biochem</source>. (<year>2001</year>) <volume>25</volume>:<fpage>277</fpage>&#x2013;<lpage>85</lpage>. doi: <pub-id pub-id-type="doi">10.1023/A:1023210620904</pub-id></citation></ref>
<ref id="ref13"><label>13.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Prohaska</surname><given-names>BK</given-names></name> <name><surname>Talwar</surname><given-names>BS</given-names></name> <name><surname>Grubbs</surname><given-names>RD</given-names></name></person-group>. <article-title>Blood biochemical status of deep-sea sharks following longline capture in the Gulf of Mexico</article-title>. <source>Conserv Physiol</source>. (<year>2021</year>) <volume>9</volume>:<fpage>coaa113</fpage>. doi: <pub-id pub-id-type="doi">10.1093/conphys/coaa113</pub-id></citation></ref>
<ref id="ref14"><label>14.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chong</surname><given-names>SK</given-names></name> <name><surname>Reineke</surname><given-names>EL</given-names></name></person-group>. <article-title>Point-of-care glucose and ketone monitoring</article-title>. <source>Top Companion Anim Med</source>. (<year>2016</year>) <volume>31</volume>:<fpage>18</fpage>&#x2013;<lpage>26</lpage>. doi: <pub-id pub-id-type="doi">10.1053/j.tcam.2016.05.005</pub-id>, PMID: <pub-id pub-id-type="pmid">27451045</pub-id></citation></ref>
<ref id="ref15"><label>15.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wess</surname><given-names>G</given-names></name> <name><surname>Reusch</surname><given-names>C</given-names></name></person-group>. <article-title>Assessment of five portable blood glucose meters for use in cats</article-title>. <source>Am J Vet Res</source>. (<year>2000</year>) <volume>61</volume>:<fpage>1587</fpage>&#x2013;<lpage>92</lpage>. doi: <pub-id pub-id-type="doi">10.2460/ajvr.2000.61.1587</pub-id>, PMID: <pub-id pub-id-type="pmid">11131603</pub-id></citation></ref>
<ref id="ref16"><label>16.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tommaso</surname><given-names>MD</given-names></name> <name><surname>Aste</surname><given-names>G</given-names></name> <name><surname>Rocconi</surname><given-names>F</given-names></name> <name><surname>Guglielmini</surname><given-names>C</given-names></name> <name><surname>Boari</surname><given-names>A</given-names></name></person-group>. <article-title>Evaluation of a portable meter to measure ketonemia and comparison with ketonuria for the diagnosis of canine diabetic ketoacidosis</article-title>. <source>J Vet Intern Med</source>. (<year>2009</year>) <volume>23</volume>:<fpage>466</fpage>&#x2013;<lpage>71</lpage>. doi: <pub-id pub-id-type="doi">10.1111/j.1939-1676.2009.0302.x</pub-id>, PMID: <pub-id pub-id-type="pmid">19645834</pub-id></citation></ref>
<ref id="ref17"><label>17.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Henderson</surname><given-names>DW</given-names></name> <name><surname>Schlesinger</surname><given-names>DP</given-names></name></person-group>. <article-title>Use of a point-of-care Beta-Hydroxybutyrate sensor for detection of Ketonemia in dogs</article-title>. <source>Can Vet J</source>. (<year>2010</year>) <volume>51</volume>:<fpage>1000</fpage>&#x2013;<lpage>2</lpage>. PMID: <pub-id pub-id-type="pmid">21119867</pub-id></citation></ref>
<ref id="ref18"><label>18.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tennent-Brown</surname><given-names>BS</given-names></name> <name><surname>Koenig</surname><given-names>A</given-names></name> <name><surname>Williamson</surname><given-names>LH</given-names></name> <name><surname>Boston</surname><given-names>RC</given-names></name></person-group>. <article-title>Comparison of three point-of-care blood glucose meters for use in adult and juvenile alpacas</article-title>. <source>J Am Vet Med Assoc</source>. (<year>2011</year>) <volume>239</volume>:<fpage>380</fpage>&#x2013;<lpage>6</lpage>. doi: <pub-id pub-id-type="doi">10.2460/javma.239.3.380</pub-id></citation></ref>
<ref id="ref19"><label>19.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Weingart</surname><given-names>C</given-names></name> <name><surname>Lotz</surname><given-names>F</given-names></name> <name><surname>Kohn</surname><given-names>B</given-names></name></person-group>. <article-title>Validation of a portable hand-held whole-blood ketone meter for use in cats</article-title>. <source>Vet Clin Pathol</source>. (<year>2012</year>) <volume>41</volume>:<fpage>114</fpage>&#x2013;<lpage>8</lpage>. doi: <pub-id pub-id-type="doi">10.1111/j.1939-165X.2011.00389.x</pub-id>, PMID: <pub-id pub-id-type="pmid">22250845</pub-id></citation></ref>
<ref id="ref20"><label>20.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zeugswetter</surname><given-names>FK</given-names></name> <name><surname>Rebuzzi</surname><given-names>L</given-names></name></person-group>. <article-title>Point-of-care &#x0392;-Hydroxybutyrate measurement for the diagnosis of feline diabetic ketoacidaemia</article-title>. <source>J Small Anim Pract</source>. (<year>2012</year>) <volume>53</volume>:<fpage>328</fpage>&#x2013;<lpage>31</lpage>. doi: <pub-id pub-id-type="doi">10.1111/j.1748-5827.2012.01204.x</pub-id>, PMID: <pub-id pub-id-type="pmid">22533366</pub-id></citation></ref>
<ref id="ref21"><label>21.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wess</surname><given-names>G</given-names></name> <name><surname>Reusch</surname><given-names>C</given-names></name></person-group>. <article-title>Evaluation of five portable blood glucose meters for use in dogs</article-title>. <source>J Am Vet Med Assoc</source>. (<year>2000</year>) <volume>216</volume>:<fpage>203</fpage>&#x2013;<lpage>9</lpage>. doi: <pub-id pub-id-type="doi">10.2460/javma.2000.216.203</pub-id>, PMID: <pub-id pub-id-type="pmid">10649754</pub-id></citation></ref>
<ref id="ref22"><label>22.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Acierno</surname><given-names>MJ</given-names></name> <name><surname>Mitchell</surname><given-names>MA</given-names></name> <name><surname>Schuster</surname><given-names>PJ</given-names></name> <name><surname>Freeman</surname><given-names>D</given-names></name> <name><surname>Sanchez-Migallon Guzman</surname><given-names>D</given-names></name> <name><surname>Jr</surname><given-names>TNT</given-names></name></person-group>. <article-title>Evaluation of the agreement among three handheld blood glucose meters and a laboratory blood analyzer for measurement of blood glucose concentration in Hispaniolan Amazon parrots (<italic>Amazona ventralis</italic>)</article-title>. <source>Am J Vet Res</source>. (<year>2009</year>) <volume>70</volume>:<fpage>172</fpage>&#x2013;<lpage>5</lpage>. doi: <pub-id pub-id-type="doi">10.2460/ajvr.70.2.172</pub-id></citation></ref>
<ref id="ref23"><label>23.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Burdick</surname><given-names>S</given-names></name> <name><surname>Mitchell</surname><given-names>MA</given-names></name> <name><surname>Neil</surname><given-names>J</given-names></name> <name><surname>Heggem</surname><given-names>B</given-names></name> <name><surname>Whittington</surname><given-names>J</given-names></name> <name><surname>Acierno</surname><given-names>MJ</given-names></name></person-group>. <article-title>Evaluation of two point-of-care meters and a portable chemistry analyzer for measurement of blood glucose concentrations in juvenile white-tailed deer (<italic>Odocoileus virginianus</italic>)</article-title>. <source>J Am Vet Med Assoc</source>. (<year>2012</year>) <volume>240</volume>:<fpage>596</fpage>&#x2013;<lpage>9</lpage>. doi: <pub-id pub-id-type="doi">10.2460/javma.240.5.596</pub-id>, PMID: <pub-id pub-id-type="pmid">22332630</pub-id></citation></ref>
<ref id="ref24"><label>24.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Petritz</surname><given-names>OA</given-names></name> <name><surname>Antinoff</surname><given-names>N</given-names></name> <name><surname>Chen</surname><given-names>S</given-names></name> <name><surname>Kass</surname><given-names>PH</given-names></name> <name><surname>Paul-Murphy</surname><given-names>JR</given-names></name></person-group>. <article-title>Evaluation of portable blood glucose meters for measurement of blood glucose concentration in ferrets (<italic>Mustela putorius furo</italic>)</article-title>. <source>J Am Vet Med Assoc</source>. (<year>2013</year>) <volume>242</volume>:<fpage>350</fpage>&#x2013;<lpage>4</lpage>. doi: <pub-id pub-id-type="doi">10.2460/javma.242.3.350</pub-id>, PMID: <pub-id pub-id-type="pmid">23327177</pub-id></citation></ref>
<ref id="ref25"><label>25.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Proulx</surname><given-names>M-P</given-names></name> <name><surname>Vergneau-Grosset</surname><given-names>C</given-names></name> <name><surname>H&#x00E9;bert</surname><given-names>J</given-names></name> <name><surname>B&#x00E9;dard</surname><given-names>C</given-names></name> <name><surname>Maccolini</surname><given-names>&#x00C9;</given-names></name></person-group>. <article-title>Comparison of a Portage blood glucose meter analyzer with a benchtop point-of-care chemistry analyzer for measurement of blood glucose concentration in client-owned ferrets (<italic>Mustela putorius furo</italic>)</article-title>. <source>J Exot Pet Med</source>. (<year>2022</year>) <volume>43</volume>:<fpage>22</fpage>&#x2013;<lpage>8</lpage>. doi: <pub-id pub-id-type="doi">10.1053/j.jepm.2022.07.004</pub-id></citation></ref>
<ref id="ref26"><label>26.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Meade</surname><given-names>SM</given-names></name> <name><surname>Di Girolamo</surname><given-names>N</given-names></name> <name><surname>Cray</surname><given-names>C</given-names></name> <name><surname>Aquilino</surname><given-names>N</given-names></name> <name><surname>DiGeronimo</surname><given-names>PM</given-names></name> <name><surname>Brand&#x00E3;o</surname><given-names>J</given-names></name></person-group>. <article-title>Point-of-care ketone meters may be used to estimate serum &#x0392;-Hydroxybutyrate concentrations in healthy African penguins (<italic>Spheniscus demersus</italic>)</article-title>. <source>Am J Vet Res</source>. (<year>2022</year>) <volume>83</volume>:<fpage>ajvr.21.11.0192</fpage>. doi: <pub-id pub-id-type="doi">10.2460/ajvr.21.11.0192</pub-id></citation></ref>
<ref id="ref27"><label>27.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hiebert</surname><given-names>K</given-names></name> <name><surname>Reich</surname><given-names>S</given-names></name> <name><surname>Allender</surname><given-names>MC</given-names></name></person-group>. <article-title>Evaluation of the agreement between 2 point-of-care glucometers and a laboratory automated analyzer in North American raptors</article-title>. <source>J Avian Med Surg</source>. (<year>2022</year>) <volume>36</volume>:<fpage>278</fpage>&#x2013;<lpage>86</lpage>. doi: <pub-id pub-id-type="doi">10.1647/21-00006</pub-id></citation></ref>
<ref id="ref28"><label>28.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lieske</surname><given-names>CL</given-names></name> <name><surname>Ziccardi</surname><given-names>MH</given-names></name> <name><surname>Mazet</surname><given-names>JAK</given-names></name> <name><surname>Newman</surname><given-names>SH</given-names></name> <name><surname>Gardner</surname><given-names>IA</given-names></name></person-group>. <article-title>Evaluation of 4 handheld blood glucose monitors for use in seabird rehabilitation</article-title>. <source>J Avian Med Surg</source>. (<year>2002</year>) <volume>16</volume>:<fpage>277</fpage>&#x2013;<lpage>85</lpage>. doi: <pub-id pub-id-type="doi">10.1647/1082-6742(2002)016[0277:EOHBGM]2.0.CO;2</pub-id></citation></ref>
<ref id="ref29"><label>29.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Westmoreland</surname><given-names>LSH</given-names></name> <name><surname>Archibald</surname><given-names>KE</given-names></name> <name><surname>Christiansen</surname><given-names>EF</given-names></name> <name><surname>Broadhurst</surname><given-names>HJ</given-names></name> <name><surname>Stoskopf</surname><given-names>MK</given-names></name></person-group>. <article-title>The mesopterygial vein: a reliable venipuncture site for intravascular access in Batoids</article-title>. <source>J Zoo Wildl Med</source>. (<year>2019</year>) <volume>50</volume>:<fpage>369</fpage>&#x2013;<lpage>74</lpage>. doi: <pub-id pub-id-type="doi">10.1638/2018-0137</pub-id>, PMID: <pub-id pub-id-type="pmid">31260202</pub-id></citation></ref>
<ref id="ref30"><label>30.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Giske&#x00F8;deg&#x00E5;rd</surname><given-names>GF</given-names></name> <name><surname>Lydersen</surname><given-names>S</given-names></name></person-group>. <article-title>Measurements below the detection limit</article-title>. <source>Tidsskr Nor Laegeforen</source>. (<year>2022</year>) <volume>142</volume>. doi: <pub-id pub-id-type="doi">10.4045/tidsskr.22.0439</pub-id></citation></ref>
<ref id="ref31"><label>31.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Beal</surname><given-names>SL</given-names></name></person-group>. <article-title>Ways to fit a Pk model with some data below the quantification limit</article-title>. <source>J Pharmacokinet Pharmacodyn</source>. (<year>2001</year>) <volume>28</volume>:<fpage>481</fpage>&#x2013;<lpage>504</lpage>. doi: <pub-id pub-id-type="doi">10.1023/A:1012299115260</pub-id></citation></ref>
<ref id="ref32"><label>32.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bland</surname><given-names>JM</given-names></name> <name><surname>Altman</surname><given-names>DG</given-names></name></person-group>. <article-title>Statistical methods for assessing agreement between two methods of clinical measurement</article-title>. <source>Lancet</source>. (<year>1986</year>) <volume>327</volume>:<fpage>307</fpage>&#x2013;<lpage>10</lpage>. doi: <pub-id pub-id-type="doi">10.1016/S0140-6736(86)90837-8</pub-id></citation></ref>
<ref id="ref33"><label>33.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Passing</surname><given-names>H</given-names></name> <name><surname>Bablok</surname><given-names>W</given-names></name></person-group>. <article-title>A new biometrical procedure for testing the equality of measurements from two different analytical methods. Application of linear regression procedures for method comparison studies in clinical chemistry, part I</article-title>. <source>J Clin Chem Clin Biochem</source>. (<year>1983</year>) <volume>21</volume>:<fpage>709</fpage>&#x2013;<lpage>20</lpage>. doi: <pub-id pub-id-type="doi">10.1515/cclm.1983.21.11.709</pub-id></citation></ref>
<ref id="ref34"><label>34.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Passing</surname><given-names>H</given-names></name> <name><surname>Bablok</surname><given-names>W</given-names></name></person-group>. <article-title>Comparison of several regression procedures for method comparison studies and determination of sample sizes. Application of linear regression procedures for method comparison studies in clinical chemistry, part II</article-title>. <source>J Clin Chem Clin Biochem</source>. (<year>1984</year>) <volume>22</volume>:<fpage>431</fpage>&#x2013;<lpage>45</lpage>. doi: <pub-id pub-id-type="doi">10.1515/cclm.1984.22.6.431</pub-id></citation></ref>
<ref id="ref35"><label>35.</label><citation citation-type="other"><person-group person-group-type="author"><name><surname>Wickham</surname><given-names>H</given-names></name> <name><surname>Fran&#x00E7;ois</surname><given-names>R</given-names></name> <name><surname>Henry</surname><given-names>L</given-names></name> <name><surname>M&#x00FC;ller</surname><given-names>K</given-names></name> <name><surname>Vaughan</surname><given-names>D</given-names></name></person-group> (<year>2023</year>). Dplyr: A grammar of data manipulation. R package version 1.1.2.</citation></ref>
<ref id="ref36"><label>36.</label><citation citation-type="other"><person-group person-group-type="author"><name><surname>Datta</surname><given-names>D.</given-names></name></person-group> (<year>2017</year>). Blandr: A Bland-Altman method comparison package for R. R package version 0.5.3.</citation></ref>
<ref id="ref37"><label>37.</label><citation citation-type="book"><person-group person-group-type="author"><name><surname>Wickham</surname><given-names>H</given-names></name></person-group>. <source>Ggplot2: Elegant Graphics for Data Analysis</source>. <publisher-loc>New York, New York</publisher-loc>: <publisher-name>Springer</publisher-name> (<year>2016</year>).</citation></ref>
<ref id="ref38"><label>38.</label><citation citation-type="other"><person-group person-group-type="author"><name><surname>Potapov</surname><given-names>S</given-names></name> <name><surname>Mode</surname><given-names>LF</given-names></name> <name><surname>Schuetzenmeister</surname><given-names>A</given-names></name> <name><surname>Manuilova</surname><given-names>E</given-names></name> <name><surname>Dufey</surname><given-names>F</given-names></name> <name><surname>Raymaekers</surname><given-names>J</given-names></name></person-group> (<year>2023</year>). Mcr: Method comparison regression. R package version 1.3.2.</citation></ref>
<ref id="ref39"><label>39.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kuznetsova</surname><given-names>A</given-names></name> <name><surname>Brockhoff</surname><given-names>P</given-names></name> <name><surname>Christensen</surname><given-names>R</given-names></name></person-group>. <article-title>Lmertest package: tests in linear mixed effects models</article-title>. <source>J Stat Softw</source>. (<year>2017</year>) <volume>82</volume>:<fpage>1</fpage>&#x2013;<lpage>26</lpage>. doi: <pub-id pub-id-type="doi">10.18637/jss.v082.i13</pub-id></citation></ref>
<ref id="ref40"><label>40.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Cain</surname><given-names>DK</given-names></name> <name><surname>Harms</surname><given-names>CA</given-names></name> <name><surname>Segars</surname><given-names>A</given-names></name></person-group>. <article-title>Plasma biochemistry reference values of wild-caught southern stingrays (<italic>Dasyatis americana</italic>)</article-title>. <source>J Zoo Wildl Med</source>. (<year>2004</year>) <volume>35</volume>:<fpage>471</fpage>&#x2013;<lpage>6</lpage>. doi: <pub-id pub-id-type="doi">10.1638/03-107</pub-id>, PMID: <pub-id pub-id-type="pmid">15732587</pub-id></citation></ref>
<ref id="ref41"><label>41.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ferreira</surname><given-names>CM</given-names></name> <name><surname>Field</surname><given-names>CL</given-names></name> <name><surname>Tuttle</surname><given-names>AD</given-names></name></person-group>. <article-title>Hematological and plasma biochemical parameters of aquarium-maintained cownose rays</article-title>. <source>J Aquat Anim Health</source>. (<year>2010</year>) <volume>22</volume>:<fpage>123</fpage>&#x2013;<lpage>8</lpage>. doi: <pub-id pub-id-type="doi">10.1577/H09-048.1</pub-id></citation></ref>
<ref id="ref42"><label>42.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Grant</surname><given-names>K</given-names></name> <name><surname>Campbell</surname><given-names>T</given-names></name></person-group>. <article-title>Hematology and plasma biochemistry value differences between acclimated and recently captive female southern stingrays, <italic>Dasyatis Americana</italic></article-title>. <source>J Zoo Aquar Res</source>. (<year>2020</year>) <volume>8</volume>:<fpage>59</fpage>&#x2013;<lpage>66</lpage>. doi: <pub-id pub-id-type="doi">10.19227/jzar.v8i1.254</pub-id></citation></ref>
<ref id="ref43"><label>43.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gerber</surname><given-names>KL</given-names></name> <name><surname>Freeman</surname><given-names>KP</given-names></name></person-group>. <article-title>ASVCP guidelines: quality assurance for portable blood glucose meter (glucometer) use in veterinary medicine</article-title>. <source>Vet Clin Pathol</source>. (<year>2016</year>) <volume>45</volume>:<fpage>10</fpage>&#x2013;<lpage>27</lpage>. doi: <pub-id pub-id-type="doi">10.1111/vcp.12310</pub-id>, PMID: <pub-id pub-id-type="pmid">26748942</pub-id></citation></ref>
<ref id="ref44"><label>44.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Selleri</surname><given-names>P</given-names></name> <name><surname>Di Girolamo</surname><given-names>N</given-names></name> <name><surname>Novari</surname><given-names>G</given-names></name></person-group>. <article-title>Performance of two portable meters and a benchtop analyzer for blood glucose concentration measurement in rabbits</article-title>. <source>J Am Vet Med Assoc</source>. (<year>2014</year>) <volume>245</volume>:<fpage>87</fpage>&#x2013;<lpage>98</lpage>. doi: <pub-id pub-id-type="doi">10.2460/javma.245.1.87</pub-id>, PMID: <pub-id pub-id-type="pmid">24941392</pub-id></citation></ref>
<ref id="ref45"><label>45.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mraovic</surname><given-names>B</given-names></name> <name><surname>Schwenk</surname><given-names>ES</given-names></name> <name><surname>Epstein</surname><given-names>RH</given-names></name></person-group>. <article-title>Intraoperative accuracy of a point-of-care glucose meter compared with simultaneous central laboratory measurements</article-title>. <source>J Diabetes Sci Technol</source>. (<year>2012</year>) <volume>6</volume>:<fpage>541</fpage>&#x2013;<lpage>6</lpage>. doi: <pub-id pub-id-type="doi">10.1177/193229681200600308</pub-id>, PMID: <pub-id pub-id-type="pmid">22768884</pub-id></citation></ref>
<ref id="ref46"><label>46.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Karon</surname><given-names>BS</given-names></name> <name><surname>Donato</surname><given-names>LJ</given-names></name> <name><surname>Larsen</surname><given-names>CM</given-names></name> <name><surname>Siebenaler</surname><given-names>LK</given-names></name> <name><surname>Wells</surname><given-names>AE</given-names></name> <name><surname>Wood-Wentz</surname><given-names>CM</given-names></name> <etal/></person-group>. <article-title>Accuracy of capillary and arterial whole blood glucose measurements using a glucose meter in patients under general anesthesia in the operating room</article-title>. <source>Anesthesiology</source>. (<year>2017</year>) <volume>127</volume>:<fpage>466</fpage>&#x2013;<lpage>74</lpage>. doi: <pub-id pub-id-type="doi">10.1097/ALN.0000000000001708</pub-id>, PMID: <pub-id pub-id-type="pmid">28557817</pub-id></citation></ref>
<ref id="ref47"><label>47.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Harr</surname><given-names>KE</given-names></name> <name><surname>Flatland</surname><given-names>B</given-names></name> <name><surname>Nabity</surname><given-names>M</given-names></name> <name><surname>Freeman</surname><given-names>KP</given-names></name></person-group>. <article-title>ASVCP guidelines: allowable total error guidelines for biochemistry</article-title>. <source>Vet Clin Pathol</source>. (<year>2013</year>) <volume>42</volume>:<fpage>424</fpage>&#x2013;<lpage>36</lpage>. doi: <pub-id pub-id-type="doi">10.1111/vcp.12101</pub-id>, PMID: <pub-id pub-id-type="pmid">24320779</pub-id></citation></ref>
<ref id="ref48"><label>48.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Clarke</surname><given-names>WL</given-names></name> <name><surname>Cox</surname><given-names>D</given-names></name> <name><surname>Gonder-Frederick</surname><given-names>LA</given-names></name> <name><surname>Carter</surname><given-names>W</given-names></name> <name><surname>Pohl</surname><given-names>SL</given-names></name></person-group>. <article-title>Evaluating clinical accuracy of systems for self-monitoring of blood glucose</article-title>. <source>Diabetes Care</source>. (<year>1987</year>) <volume>10</volume>:<fpage>622</fpage>&#x2013;<lpage>8</lpage>. doi: <pub-id pub-id-type="doi">10.2337/diacare.10.5.622</pub-id>, PMID: <pub-id pub-id-type="pmid">3677983</pub-id></citation></ref>
<ref id="ref49"><label>49.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Parkes</surname><given-names>JL</given-names></name> <name><surname>Slatin</surname><given-names>SL</given-names></name> <name><surname>Pardo</surname><given-names>S</given-names></name> <name><surname>Ginsberg</surname><given-names>BH</given-names></name></person-group>. <article-title>A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose</article-title>. <source>Diabetes Care</source>. (<year>2000</year>) <volume>23</volume>:<fpage>1143</fpage>&#x2013;<lpage>8</lpage>. doi: <pub-id pub-id-type="doi">10.2337/diacare.23.8.1143</pub-id>, PMID: <pub-id pub-id-type="pmid">10937512</pub-id></citation></ref>
<ref id="ref50"><label>50.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mylniczenko</surname><given-names>ND</given-names></name> <name><surname>Curtis</surname><given-names>EW</given-names></name> <name><surname>Wilborn</surname><given-names>RE</given-names></name> <name><surname>Young</surname><given-names>FA</given-names></name></person-group>. <article-title>Differences in hematocrit of blood samples obtained from two venipuncture sites in sharks</article-title>. <source>Am J Vet Res</source>. (<year>2006</year>) <volume>67</volume>:<fpage>1861</fpage>&#x2013;<lpage>4</lpage>. doi: <pub-id pub-id-type="doi">10.2460/ajvr.67.11.1861</pub-id>, PMID: <pub-id pub-id-type="pmid">17078747</pub-id></citation></ref>
<ref id="ref51"><label>51.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Phillips</surname><given-names>BE</given-names></name> <name><surname>Christiansen</surname><given-names>EF</given-names></name> <name><surname>Stoskopf</surname><given-names>MK</given-names></name> <name><surname>Broadhurst</surname><given-names>H</given-names></name> <name><surname>George</surname><given-names>R</given-names></name> <name><surname>Harms</surname><given-names>CA</given-names></name></person-group>. <article-title>Comparison of hematology, plasma biochemistry, and blood gas variables between 2 venipuncture sites in southern stingrays (<italic>Dasyatis americana</italic>)</article-title>. <source>Vet Clin Pathol</source>. (<year>2016</year>) <volume>45</volume>:<fpage>627</fpage>&#x2013;<lpage>33</lpage>. doi: <pub-id pub-id-type="doi">10.1111/vcp.12424</pub-id>, PMID: <pub-id pub-id-type="pmid">27977062</pub-id></citation></ref>
</ref-list>
</back>
</article>