<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Vet. Sci.</journal-id>
<journal-title>Frontiers in Veterinary Science</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Vet. Sci.</abbrev-journal-title>
<issn pub-type="epub">2297-1769</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fvets.2022.887676</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Veterinary Science</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Biomechanical Test of a New Endoprosthesis for Cylindrical Medullary Canals in Dogs</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes">
<name><surname>Mendaza-DeCal</surname> <given-names>Rosa</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="corresp" rid="c001"><sup>&#x0002A;</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/1299961/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Ballesteros</surname> <given-names>Yolanda</given-names></name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Peso-Fernandez</surname> <given-names>Salvador</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/1445887/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Paz</surname> <given-names>Eva</given-names></name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>del Real-Romero</surname> <given-names>Juan Carlos</given-names></name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Rodriguez-Quiros</surname> <given-names>Jesus</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/1377786/overview"/>
</contrib>
</contrib-group>
<aff id="aff1"><sup>1</sup><institution>Animal Medicine and Surgery Department, Veterinary Faculty, Complutense University of Madrid</institution>, <addr-line>Madrid</addr-line>, <country>Spain</country></aff>
<aff id="aff2"><sup>2</sup><institution>ABAX Innovation Technologies, Villanueva de la Ca&#x000F1;ada</institution>, <addr-line>Madrid</addr-line>, <country>Spain</country></aff>
<aff id="aff3"><sup>3</sup><institution>Institute for Research in Technology/Mechanical Engineering Department, Universidad Pontificia Comillas</institution>, <addr-line>Madrid</addr-line>, <country>Spain</country></aff>
<author-notes>
<fn fn-type="edited-by"><p>Edited by: Mauro Malv&#x000E8;, Public University of Navarre, Spain</p></fn>
<fn fn-type="edited-by"><p>Reviewed by: Caitlyn J. Collins, Virginia Tech, United States; Feihu Zhao, Swansea University, United Kingdom</p></fn>
<corresp id="c001">&#x0002A;Correspondence: Rosa Mendaza-DeCal <email>rmendaza&#x00040;ucm.es</email></corresp>
<fn fn-type="other" id="fn001"><p>This article was submitted to Veterinary Surgery and Anesthesiology, a section of the journal Frontiers in Veterinary Science</p></fn></author-notes>
<pub-date pub-type="epub">
<day>30</day>
<month>06</month>
<year>2022</year>
</pub-date>
<pub-date pub-type="collection">
<year>2022</year>
</pub-date>
<volume>9</volume>
<elocation-id>887676</elocation-id>
<history>
<date date-type="received">
<day>01</day>
<month>03</month>
<year>2022</year>
</date>
<date date-type="accepted">
<day>02</day>
<month>06</month>
<year>2022</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x000A9; 2022 Mendaza-DeCal, Ballesteros, Peso-Fernandez, Paz, del Real-Romero and Rodriguez-Quiros.</copyright-statement>
<copyright-year>2022</copyright-year>
<copyright-holder>Mendaza-DeCal, Ballesteros, Peso-Fernandez, Paz, del Real-Romero and Rodriguez-Quiros</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license> </permissions>
<abstract>
<p>Exo-endoprosthesis is a limb salvage procedure for animals, although only expensive metal devices have been described. Now-a-days, new materials for this type of implant could be considered due to novel and affordable manufacturing techniques. However, a factor of safety (FoS) should be considered. There are kinetic and kinematic studies of canine natural gaits, which can be used to establish an FoS for mechanical tests for new non-metallic devices. Polyetheretherketone (PEEK) is used in different specialties in human medicine. Its mechanical properties (and its close mechanical stiffness to that of bone) make this polymer an alternative to metals in veterinary traumatology. PEEK could also be used in 3D printing. The suitability of a novel inner part of an exo-endoprosthesis manufactured by fuse deposition modeling (FDM) was presented in this study for long canine bones. Mechanical characterization of 3D-printed PEEK material and <italic>ex vivo</italic> mechanical tests of a customized endoprosthesis were performed to address it. Young&#x00027;s modulus of 3D-printed PEEK suffered a reduction of 30% in relation to bulk PEEK. Customized 3D-printed PEEK endoprostheses had promising outcomes for the tibiae of 20 kg dogs. Pure compression tests of the non-inserted endoprostheses showed a maximum force of 936 &#x000B1; 199 N. In the bending tests of non-inserted endoprostheses, the PEEK part remained intact. Quasistatic mechanical tests of bone-inserted endoprostheses (compression-bending and pure compression tests) reached a maximum force of 785 &#x000B1; 101 N and 1,642 &#x000B1; 447 N, respectively. In fatigue tests, the samples reached 500,000 cycles without failure or detriment to their quasistatic results. These outcomes surpass the natural weight-bearing of dogs, even during a galloping pace. In conclusion, the 3D-printed PEEK part of the endoprosthesis for an exo-endoprosthesis can withstand loading, even during a galloping pace.</p></abstract>
<kwd-group>
<kwd>biomechanical test</kwd>
<kwd>patient-specific implant</kwd>
<kwd>FDM</kwd>
<kwd>PEEK</kwd>
<kwd>exo-endoprosthesis</kwd>
<kwd><italic>ex vivo</italic></kwd>
<kwd>tibia</kwd>
<kwd>canine</kwd>
</kwd-group>
<contract-sponsor id="cn001">Comunidad de Madrid<named-content content-type="fundref-id">10.13039/100012818</named-content></contract-sponsor>
<counts>
<fig-count count="8"/>
<table-count count="2"/>
<equation-count count="1"/>
<ref-count count="49"/>
<page-count count="13"/>
<word-count count="7112"/>
</counts>
</article-meta>
</front>
<body>
<sec sec-type="intro" id="s1">
<title>Introduction</title>
<p>Exo-endoprosthesis is a limb salvage procedure in humans and, to a lesser extent, in animals (<xref ref-type="bibr" rid="B1">1</xref>&#x02013;<xref ref-type="bibr" rid="B5">5</xref>). Because the implant is inserted into the medullary canal of a long bone, its advantages are no pain, no delay in load transfer, energetic efficiency, and good proprioception. However, complications have been reported, such as infection, skin breakdown, aseptic loosening, device failure, and avulsion (<xref ref-type="bibr" rid="B2">2</xref>, <xref ref-type="bibr" rid="B5">5</xref>, <xref ref-type="bibr" rid="B6">6</xref>). The two last complications can be related to stress-shielding phenomena (<xref ref-type="bibr" rid="B7">7</xref>). Therefore, aseptic loosening and stress-shielding are related to the higher stiffness of metals as compared to bone (<xref ref-type="bibr" rid="B7">7</xref>, <xref ref-type="bibr" rid="B8">8</xref>) and metallic debris. A rigid material is reluctant to deform and difficult to adapt when it is inserted in a flexible object, like the medullary canal of a bone. So perfect fitting of the rigid material to the bone cannot be expected. This mismatch produces a lack of stress transmission between rigid material and bone, which is one of the reasons for stress-shielding. In the same way, it is the flexible material, the bone, which is deformed because of the rigid material in case of irregular stress transmission. Thus, these phenomena are related to the chosen material of a medical device, and their effect could be reduced by selecting other materials with a stiffness closer to the bone. Now-a-days, all veterinary implants are individualized, and made in metal. These characteristics make them an expensive solution that few owners can afford for their pets.</p>
<p>Seeking price reduction and avoiding the aforementioned complications related to metal stiffness, other materials could be considered for implants. The stiffness is directly related to the elastic properties of a material, such as Young&#x00027;s modulus, tensile strength, and bending strength among others (<xref ref-type="bibr" rid="B9">9</xref>). Materials with a much higher Young&#x00027;s modulus, such as metals, when compared with bone, could be prone to stress-shielding of the host bone due to their rigidity (<xref ref-type="bibr" rid="B7">7</xref>, <xref ref-type="bibr" rid="B10">10</xref>). Therefore, a non-metallic material with bone-like elastic properties could be considered to reduce the aseptic loosening and stress-shielding of a medical device on a bone.</p>
<p>Polyetheretherketone (PEEK) is one of those alternative non-metallic materials for medical devices. PEEK is a thermoplastic of the polyaryletherketone family that is generally used for different specialties in human medicine, such as neurosurgery, traumatology, and dental and craniomaxillofacial surgery (<xref ref-type="bibr" rid="B11">11</xref>, <xref ref-type="bibr" rid="B12">12</xref>). PEEK is also bioinert in the physiological environment and has good biocompatibility (<xref ref-type="bibr" rid="B11">11</xref>). It is one of the polymers with good mechanical properties, such as its weight-bearing and strength properties (<xref ref-type="bibr" rid="B11">11</xref>). Furthermore, its stiffness is closer to that of bone than to that of metal (<xref ref-type="bibr" rid="B11">11</xref>). All of these specific characteristics make it a candidate for the avoidance of stress-shielding as is assessed on ovine or canine specimens in experimental studies for different traumatological devices (<xref ref-type="bibr" rid="B11">11</xref>&#x02013;<xref ref-type="bibr" rid="B14">14</xref>).</p>
<p>Now-a-days, thanks to additive manufacturing (AM), quite a range of materials can be considered for manufacturing small productions of final devices with a minimum cost (<xref ref-type="bibr" rid="B15">15</xref>, <xref ref-type="bibr" rid="B16">16</xref>). There are different technologies in the field of AM, although only direct metal laser sintering (DMLS) has been reported in papers in the field of veterinary medicine as a manufacturing method for endoprosthesis or intraosseous implants (<xref ref-type="bibr" rid="B5">5</xref>, <xref ref-type="bibr" rid="B6">6</xref>, <xref ref-type="bibr" rid="B17">17</xref>, <xref ref-type="bibr" rid="B18">18</xref>). This type of technology is cheaper than traditional manufacturing (<xref ref-type="bibr" rid="B15">15</xref>). However, it is still quite expensive when compared with fused deposition modeling (FDM) (<xref ref-type="bibr" rid="B16">16</xref>). Currently, there are a few patents for 3D-printed exo-endoprostheses that are manufactured in FDM, such as ES2736410A1 (<xref ref-type="bibr" rid="B19">19</xref>) or US10925755B2 (<xref ref-type="bibr" rid="B20">20</xref>). Nevertheless, the mechanical properties of polymers manufactured by FDM should be evaluated, as these properties are usually inferior to those obtained by the injection molding process (<xref ref-type="bibr" rid="B21">21</xref>&#x02013;<xref ref-type="bibr" rid="B23">23</xref>). Thus, preliminary tests are recommended with tensile test samples of the studied polymers. Tensile test samples are shaped according to ISO 527-1 (<xref ref-type="bibr" rid="B24">24</xref>).</p>
<p>To assess a new material for a load-bearing device, a factor of safety (FoS) should be determined to endorse the feasibility of the material for that activity and situation. Currently, the FoS and working load have not been determined for veterinary limb salvage devices. Working load is the applied load on the device during the activity. FoS is a ratio defined for any mechanical device to avoid failure during its work, expressed as the ratio of the maximum load (failure load) to the working load. As a working load, these devices will withstand different body weights (BWs) according to the type of pace and moment of the stance phase (<xref ref-type="bibr" rid="B25">25</xref>&#x02013;<xref ref-type="bibr" rid="B27">27</xref>) during the gait cycle. Each canine pelvic limb bears approximately 0.44 times its BW during walking (<xref ref-type="bibr" rid="B28">28</xref>, <xref ref-type="bibr" rid="B29">29</xref>), around 0.71 times its BW during trotting (<xref ref-type="bibr" rid="B25">25</xref>), and 1.5 times its BW while dogs are in a steady gallop (<xref ref-type="bibr" rid="B26">26</xref>, <xref ref-type="bibr" rid="B30">30</xref>). To compare the aforementioned weight-bearing forces, data have been normalized to the BW of animals using the BW equation described by Krotscheck et al. (<xref ref-type="bibr" rid="B31">31</xref>). Hence, these values could be considered as working load for determining the FoS for <italic>ex vivo</italic> mechanical testing of new load-bearing implants. Currently, published quasistatic and dynamic mechanical tests of other veterinary implants (<xref ref-type="bibr" rid="B5">5</xref>, <xref ref-type="bibr" rid="B32">32</xref>, <xref ref-type="bibr" rid="B33">33</xref>) just expected device failure without relating it to an actual canine weight-bearing force. In addition, the mechanical tests will need the placement of the bone specimens as close as possible to the real positions during canine paces. Kinematic studies can be used as a reference for this issue. A range of 126&#x000B0; to 147.2&#x000B0; is collected for a stifle joint during walking at a stance stage (<xref ref-type="bibr" rid="B34">34</xref>), while a range of 107&#x000B0; to 159&#x000B0; is registered at trotting, galloping, and acceleration (<xref ref-type="bibr" rid="B27">27</xref>, <xref ref-type="bibr" rid="B30">30</xref>). These data give an average stifle angle of 135&#x000B0;, which is the assumed value of this joint for dogs in veterinary medicine. In a dynamic test, the stride per second of each pace can be used as a reference for adjusting frequency values (<xref ref-type="bibr" rid="B35">35</xref>). Strides per second range approximately from 3 to 1 depending on galloping to walking pace, respectively.</p>
<p>The aim of this study is to determine if PEEK material in contact with the bone could be a possible weight-bearing option for canine patients during their regular gaits. This work describes initial <italic>ex vivo</italic> research on the use of a PEEK sleeve to interface between the bone and inner part of an exo-endoprosthesis in the context of limb-sparing surgery. The 3D-printed endoprosthetic element was tested by new loading protocols to mimic normal canine loads during walking, trotting, and galloping. To our knowledge, no evidence of mechanical tests was found for other exo-endoprostheses in veterinary medicine.</p></sec>
<sec sec-type="methods" id="s2">
<title>Methods</title>
<sec>
<title>Endoprosthesis Design</title>
<p>The assessed endoprosthesis was patented by Mendaza et al. (<xref ref-type="bibr" rid="B19">19</xref>) and was composed of two main elements: (i) the PEEK sleeve, composed of a base, &#x0201C;umbrella&#x0201D;, neck, and stem (<xref ref-type="bibr" rid="B36">36</xref>), which will be in contact with bone tissue, and (ii) surgical metal threaded rod, made of AISI 316 austenitic stainless steel, which will be attached to an exoprosthesis (<xref ref-type="fig" rid="F1">Figure 1</xref>).</p>
<fig id="F1" position="float">
<label>Figure 1</label>
<caption><p><bold>(A)</bold> 3D-rendered model of the tibial endoprosthesis and <bold>(B)</bold> 3D-rendered assembly of the exo-endoprosthesis inserted into a tibia. The exo-prosthesis part (blue) is an example of the ideal construct. Where (1) represents the stem; and (2) represents an approximation base- &#x0201C;umbrella&#x0201D; section.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fvets-09-887676-g0001.tif"/>
</fig>
<p>The PEEK sleeve of the endoprosthesis was designed with a CAD program (SolidWorks, SolidWorks Corp., Waltham, MA). The external diameter of the stem was 0.40 mm larger than the drilled medullary canal of a tibia (9 mm). Thus, all external diameters of the stems measured 9.40 mm. The diameter of the inner cavity of the PEEK sleeve was 6 mm just like the diameter of the threaded rod. This cavity was slightly reduced at the level of the stem for applying extra-radial compression to the bone, such as that described by Mendaza-DeCal et al. (<xref ref-type="bibr" rid="B36">36</xref>).</p></sec>
<sec>
<title>3D Printing Material</title>
<p>Tibia endoprostheses and tensile and bending test samples were printed in PEEK (3D4Makers, Amsterdam, Netherlands). Filaments were stored in a special ziplock multi-layered bag with a special EVOH barrier film and silica desiccant sachets provided by the filament supplier. Otherwise, following the recommended protocols in the literature (<xref ref-type="bibr" rid="B22">22</xref>) and by filament manufacturers, spools were dried at 150 &#x000B0;C for 3 h in a dry heat oven before printing with PEEK.</p></sec>
<sec>
<title>3D Printing Manufacturing Parameters</title>
<p>Tensile and bending test samples and endoprostheses were printed by FunMat HT (INTAMSYS, Shanghai, China) based on FDM technology, with a build volume of 260 mm &#x000D7; 260 mm &#x000D7; 260 mm (x, y, and z). The printer has a hardened steel nozzle of 0.4 mm diameter. This printer reaches a nozzle temperature of up to 450 &#x000B0;C, bed temperature of up to 160 &#x000B0;C, and chamber temperature of up to 90 &#x000B0;C. Before printing, 3D virtual models were sliced by Simplify 3D software (Cincinnati, USA).</p>
<p>All 3D models were horizontally oriented with respect to the printing bed (<xref ref-type="bibr" rid="B36">36</xref>). The largest axes of the endoprostheses and tensile test samples with dog bone shapes were oriented parallel to the printing bed (<xref ref-type="fig" rid="F2">Figure 2</xref>). Endoprosthesis dimensions were 16.54<sup>&#x0002A;</sup>50.21<sup>&#x0002A;</sup>14.72 mm<sup>3</sup>, which are x, y, and z of the printing bed, respectively. Also, the bending test samples were printed like rectangular bars, with the same printing orientation as the other 3D models. A horizontal orientation was carried out to take into account the main mechanical forces borne inside the medullary canal. The general printing parameters were constant for all 3D models, which are shown in <xref ref-type="table" rid="T1">Table 1</xref>. Also, the temperature parameters were the same for both 3D models: nozzle temperature of 410 &#x000B0;C, bed temperature of 130 &#x000B0;C, chamber temperature of 90 &#x000B0;C, and the cooling fan speed of 50%. All these parameters were set without variants between the 3D models because it has been proven that the mechanical properties of 3D-printed models varied due to printing conditions (<xref ref-type="bibr" rid="B21">21</xref>, <xref ref-type="bibr" rid="B23">23</xref>, <xref ref-type="bibr" rid="B37">37</xref>).</p>
<fig id="F2" position="float">
<label>Figure 2</label>
<caption><p>Printing simulation of <bold>(A)</bold> dog bone sample (its dimensions were 75 &#x000B1; 0.5 mm length, 5 &#x000B1; 0.2 mm width, and 3.5 &#x000B1; 0.2 mm thickness, with a gauge length of 25 &#x000B1; 0.5 mm) and <bold>(B)</bold> endoprosthesis (its dimensions were 16.54&#x0002A;50.21&#x0002A;14.72 mm<sup>3</sup>, which are width, length, and thickness of the printing bed, respectively) in Simplify 3D.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fvets-09-887676-g0002.tif"/>
</fig>
<table-wrap position="float" id="T1">
<label>Table 1</label>
<caption><p>Characteristics of FDM printings at Simplify 3D slicer. DB- and RB- samples, are tensile test and bending test samples.</p></caption>
<table frame="hsides" rules="groups">
<thead><tr>
<th/>
<th/>
<th valign="top" align="center"><bold>Tibial endo-prosthesis</bold></th>
<th valign="top" align="center"><bold>DB- and RB- samples</bold></th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left" colspan="2">N&#x000B0; Models each printing</td>
<td valign="top" align="center">2 (40 mm distance between them)</td>
<td valign="top" align="center">1</td>
</tr>
<tr>
<td valign="top" align="left" colspan="2">Extrusion multiplier</td>
<td valign="top" align="center">0.92</td>
<td valign="top" align="center">0.92</td>
</tr>
<tr>
<td valign="top" align="left" colspan="2">Layer height (mm)</td>
<td valign="top" align="center">0.05</td>
<td valign="top" align="center">0.05</td>
</tr>
<tr>
<td valign="top" align="left">Skirt</td>
<td valign="top" align="left"><italic>Layer</italic></td>
<td valign="top" align="center">1</td>
<td valign="top" align="center">1</td>
</tr>
<tr>
<td/>
<td valign="top" align="left"><italic>Skirt outlines</italic></td>
<td valign="top" align="center">15</td>
<td valign="top" align="center">15</td>
</tr>
<tr>
<td valign="top" align="left" colspan="2">Infill (%)</td>
<td valign="top" align="center">50</td>
<td valign="top" align="center">50</td>
</tr>
<tr>
<td valign="top" align="left">Speed</td>
<td valign="top" align="left"><italic>Default (mm/s)</italic></td>
<td valign="top" align="center">30</td>
<td valign="top" align="center">30</td>
</tr>
<tr>
<td/>
<td valign="top" align="left"><italic>Outline underspeed (%)</italic></td>
<td valign="top" align="center">50</td>
<td valign="top" align="center">50</td>
</tr>
<tr>
<td/>
<td valign="top" align="left"><italic>Solid infill underspeed (%)</italic></td>
<td valign="top" align="center">80</td>
<td valign="top" align="center">80</td>
</tr>
<tr>
<td/>
<td valign="top" align="left"><italic>Supports underspeed (%)</italic></td>
<td valign="top" align="center">80</td>
<td valign="top" align="center">80</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>Furthermore, immediately before each printing, a specific liquid fixative (Dimafix, DIMA 3D, Valladolid, Spain) for 3D printing was applied to the cold print bed for better adhesion of the material during printing. A preheat of the chamber and build bed temperatures were set and allowed to stabilize for at least for 30 min before starting any printing.</p></sec>
<sec>
<title>Preparation of the Endoprosthesis-Tibia Construct</title>
<p>The endoprosthesis-tibia interface will be referred to as endoprosthesis-tibia construct in this article. The construct was assessed by mechanical tests. <italic>Ex vivo</italic> fresh tibiae were used to insert the endoprostheses. The 33 tibiae used for this study belonged to canine specimens (20.85 &#x000B1; 1.25 kg BW) that were euthanized for reasons unrelated to this study. The longitudinal length of tibiae was 208.51 &#x000B1; 40.27 mm. The fresh bones were immediately stored inside a vacuum bag in a freezer until the insertion of the endoprosthesis. Bones were perpendicularly cut to the longitudinal axes above the distal epiphysis. Immediately, the medullary canals of the tibiae were measured on the cut plane by a metric digital caliper. Tibiae with an average medullary canal diameter of 9.48 &#x000B1; 0.29 mm were selected. This average medullary canal diameter was observed on the selected canine specimens. After measure, the medullary canal was drilled with a 9 mm bit to homogenize the canal. Two PLA 3D-printed self-designed surgical guides were used to make perpendicular cuts and to align drilling (<xref ref-type="fig" rid="F3">Figure 3</xref>) (<xref ref-type="bibr" rid="B36">36</xref>). Insertion of the endoprosthesis was made by soft blows with a hammer. Later, an AISI 316 austenitic stainless steel threaded rod with a diameter of 6 mm was gently inserted using a locknut, with a length of 30 mm being left outside the PEEK sleeve. Cutting, drilling, and insertion were carried out by the same operator.</p>
<fig id="F3" position="float">
<label>Figure 3</label>
<caption><p>Transverse cut <bold>(A)</bold> and MC-concentric drill <bold>(B)</bold> guides. Both self-designed and printed at PLA. At <bold>(A)</bold>, the red dash line represents where the transversal cut was made on the distal tibia. At <bold>(B)</bold>, the red arrow represents the drilling direction of the MC to homogenize the MC diameter.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fvets-09-887676-g0003.tif"/>
</fig>
<p>Once the endoprostheses were inserted, 25 tibiae were attached with a two-component epoxy resin (Resoltech 1050/1058S, Eguilles, France) in aluminum holders. Tibiae were cured in the holders at half the average angle of the stifle joint when the dog is standing (<xref ref-type="fig" rid="F4">Figure 4A</xref>), as described by Holler et al. (<xref ref-type="bibr" rid="B38">38</xref>). The angle value of attachment was 67&#x000B0; of the tibial axis to the test table (<xref ref-type="fig" rid="F4">Figure 4B</xref>) for compression-bending and fatigue tests. This angle is consistent with the average angle in maximum weight-bearing during trotting, acceleration, and galloping, as it has been described in the introduction section. The remaining eight tibiae were perpendicularly clamped to the test table for a pure compression test.</p>
<fig id="F4" position="float">
<label>Figure 4</label>
<caption><p><bold>(A)</bold> Schematic figure of the decompounded ground reaction force (black arrow) on the canine tibia in compression (green arrow) and bending forces (pink arrow). Angle of the stifle joint (135&#x000B0;) was split in half by a red line as a reference for testing. <bold>(B)</bold> Endoprosthesis-tibia construct at 67&#x000B0; to the testing table for compression-bending and fatigue testing.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fvets-09-887676-g0004.tif"/>
</fig></sec>
<sec>
<title>Mechanical Testing</title>
<sec>
<title>Mechanical Characterization of the 3D-Printed PEEK</title>
<p>The tensile properties of the 3D-printed PEEK were determined using tensile test samples with dog bone shapes (DB-samples) (<xref ref-type="bibr" rid="B39">39</xref>) (<xref ref-type="fig" rid="F2">Figure 2A</xref>). The dimensions for each sample were 75 &#x000B1; 0.5 mm in length, 5 &#x000B1; 0.2 mm in width, and 3.5 &#x000B1; 0.2 mm in thickness, with a gauge length of 25 &#x000B1; 0.5 mm. All these measurements were according to the Spanish standard UNE 116005:2012 (<xref ref-type="bibr" rid="B39">39</xref>). Tests were performed according to ISO 527-1 (<xref ref-type="bibr" rid="B24">24</xref>) using the universal testing machine Elib 20W (SAE Ibertest Madrid, Spain) with a load cell of 2 kN, which operated at a crosshead speed of 1 mm/min.</p>
<p>A three-point bending load arrangement was used to determine the bending properties in accordance with ISO 178 (<xref ref-type="bibr" rid="B40">40</xref>). The tests were conducted using the universal testing machine IBTH/500 (Ibertest, Madrid, Spain) with a load cell of 500 N, which operated at a crosshead speed of 5 mm/min. For the bending tests, the samples were rectangular bars (RB-samples) with dimensions of 80.0 &#x000B1; 0.1 mm length, 10.0 &#x000B1; 0.1 mm width, and 4.0 &#x000B1; 0.1 mm thickness [dimensions according to the Spanish standard UNE 116005:2012 (<xref ref-type="bibr" rid="B39">39</xref>)]. Eight samples were tested for each kind of test.</p>
<p>The results of the elastic properties were compared with those of canine tibiae, bulk PEEK, 316L stainless steel (316L-SS), and titanium (Ti) obtained from the literature (<xref ref-type="table" rid="T2">Table 2</xref>).</p>
<table-wrap position="float" id="T2">
<label>Table 2</label>
<caption><p>Elastic properties of bulk PEEK, stainless steel, titanium, and canine tibia obtained from the literature.</p></caption>
<table frame="hsides" rules="groups">
<thead><tr>
<th valign="top" align="left"><bold>Material</bold></th>
<th valign="top" align="center"><bold>Tensile strength (MPa)</bold></th>
<th valign="top" align="center"><bold>Young&#x00027;s modulus (GPa)</bold></th>
<th valign="top" align="center"><bold>Bending strength (MPa)</bold></th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Bulk PEEK (<xref ref-type="bibr" rid="B41">41</xref>)</td>
<td valign="top" align="center">97&#x02013;117</td>
<td valign="top" align="center">3.76&#x02013;3.95</td>
<td valign="top" align="center">105&#x02013;116</td>
</tr>
<tr>
<td valign="top" align="left">316L-SS (<xref ref-type="bibr" rid="B41">41</xref>&#x02013;<xref ref-type="bibr" rid="B43">43</xref>)</td>
<td valign="top" align="center">90&#x02013;1,100</td>
<td valign="top" align="center">193&#x02013;210</td>
<td valign="top" align="center">170&#x02013;310</td>
</tr>
<tr>
<td valign="top" align="left">Ti (46,47)</td>
<td valign="top" align="center">240&#x02013;1,100</td>
<td valign="top" align="center">110</td>
<td valign="top" align="center">130&#x02013;1,280</td>
</tr>
<tr>
<td valign="top" align="left">Canine Tibia (<xref ref-type="bibr" rid="B44">44</xref>, <xref ref-type="bibr" rid="B45">45</xref>)</td>
<td valign="top" align="center">107.7&#x02013;199.12</td>
<td valign="top" align="center">8.85&#x02013;15.59</td>
<td valign="top" align="center">142&#x02013;193</td>
</tr>
</tbody>
</table>
</table-wrap></sec>
<sec>
<title>Quasistatic Mechanical Testing of the Endoprosthesis</title>
<p>Pure compression (<xref ref-type="fig" rid="F5">Figure 5A</xref>) and bending (<xref ref-type="fig" rid="F5">Figure 5B</xref>) tests were carried out onto endoprostheses themselves (E-samples) using the universal testing machine Elib 20W with a load cell of 2 kN, which operated at a crosshead speed of 500 mm/min. Five samples were tested for each kind of test. The aim of these tests was to find the weakest zone of the endoprosthesis and estimate if the mechanical strength of the endoprosthesis in the main load direction (vertical position) was enough to support the BW of the dog.</p>
<fig id="F5" position="float">
<label>Figure 5</label>
<caption><p><bold>(A)</bold> Pure compression (endoprosthesis at vertical position) and <bold>(B)</bold> bending test (endoprosthesis at horizontal position) of the endoprosthesis. Yellow arrows represent the direction of the applied force.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fvets-09-887676-g0005.tif"/>
</fig></sec>
<sec>
<title>Pure Compression and Compression&#x02013;Bending Testing of the Endoprosthesis-Tibia Construct</title>
<p>To obtain a more realistic result about the mechanical behavior of the endoprosthesis-tibia construct, samples (ET-samples) were prepared as described in section 2.4 above for pure compression (90&#x000B0;) and compression-bending test (67&#x000B0;). Each of the ET samples was assessed using the universal testing machine Elib 20 W (SAE Ibertest Madrid, Spain) with a load cell of 2 kN (<xref ref-type="fig" rid="F6">Figure 6A</xref>). Tests were conducted under room conditions (22 &#x000B1; 1 &#x000B0;C). Bones of ET-samples were covered with a gauze soaked in phosphate buffer solution (PBS) to maintain the correct pH and degree of humidity, simulating the <italic>in vivo</italic> conditions. Eight ET-samples were evaluated by pure compression testing (<xref ref-type="fig" rid="F6">Figure 6A</xref>) and 15 ET-samples by compression-bending testing (<xref ref-type="fig" rid="F6">Figure 6B</xref>) at a crosshead speed of 500 mm/min.</p>
<fig id="F6" position="float">
<label>Figure 6</label>
<caption><p>Pure compression <bold>(A)</bold> and compression-bending <bold>(B)</bold> tests of endoprosthesis-tibia construct. <bold>(A)</bold> samples were tested clamped directly to the bone, and <bold>(B)</bold> samples were potted at 67&#x000B0; to the ground before testing. Red arrows represent the direction of the applied force.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fvets-09-887676-g0006.tif"/>
</fig></sec>
<sec>
<title>Fatigue Compression-Bending Testing of the Endoprosthesis-Tibia Construct</title>
<p>Fatigue tests are particularly important to study the long-term behavior of the endoprosthesis-tibia construct. The load to be supported by the tibia can be approximated by equation 1 (<xref ref-type="bibr" rid="B26">26</xref>, <xref ref-type="bibr" rid="B30">30</xref>). For a theoretical 20 kg dog, if we consider the most unfavorable circumstances (dog at galloping), the maximum load to support would be approximately 300 N. This value was also considered as a working load to determine the FoS.</p>
<disp-formula id="E1"><label>(1)</label><mml:math id="M1"><mml:mtable class="eqnarray" columnalign="right center left"><mml:mtr><mml:mtd><mml:mi>M</mml:mi><mml:mi>a</mml:mi><mml:mi>x</mml:mi><mml:mi>i</mml:mi><mml:mi>m</mml:mi><mml:mi>u</mml:mi><mml:mi>m</mml:mi><mml:mtext>&#x000A0;</mml:mtext><mml:mi>l</mml:mi><mml:mi>o</mml:mi><mml:mi>a</mml:mi><mml:mi>d</mml:mi><mml:mtext>&#x000A0;</mml:mtext><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:mi>N</mml:mi></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow><mml:mo>=</mml:mo><mml:mn>1</mml:mn><mml:mo>.</mml:mo><mml:mn>5</mml:mn><mml:mtext>&#x000A0;</mml:mtext><mml:mi>x</mml:mi><mml:mtext>&#x000A0;</mml:mtext><mml:mi>D</mml:mi><mml:mi>W</mml:mi><mml:mtext>&#x000A0;</mml:mtext><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:mi>d</mml:mi><mml:mi>o</mml:mi><mml:mi>g</mml:mi><mml:mtext>&#x000A0;</mml:mtext><mml:mi>w</mml:mi><mml:mi>e</mml:mi><mml:mi>i</mml:mi><mml:mi>g</mml:mi><mml:mi>h</mml:mi><mml:mi>t</mml:mi><mml:mtext>&#x000A0;</mml:mtext><mml:mi>i</mml:mi><mml:mi>n</mml:mi><mml:mtext>&#x000A0;</mml:mtext><mml:mi>k</mml:mi><mml:mi>g</mml:mi></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow><mml:mtext>&#x000A0;</mml:mtext><mml:mi>x</mml:mi><mml:mtext>&#x000A0;</mml:mtext><mml:mn>9</mml:mn><mml:mo>.</mml:mo><mml:mn>8</mml:mn></mml:mtd></mml:mtr></mml:mtable></mml:math></disp-formula>
<p>Fatigue testing was conducted under room conditions (22 &#x000B1; 1 &#x000B0;C) using an electrodynamic testing machine with a load cell of 3 kN (ElectroPlus E3000, Instron, Norwood, MA, USA). ET-samples were prepared as described in section 2.4 (<xref ref-type="fig" rid="F6">Figure 6B</xref>) for compression-bending testing. These samples were assessed until failure or until 500,000 cycles, using a sinusoidal force cycle with a maximum load of 300 N and a load ratio of <italic>R</italic> = 0.1. A frequency of 2 Hz was used for the test, which is similar to the pacing frequency when the dog is trotting. Under these conditions, 10 ET-samples were evaluated.</p></sec></sec>
<sec>
<title>Statistical Analysis</title>
<p>Data from pure compression of E-samples and ET-samples tests were analyzed by analysis of variance (ANOVA) using the STATGRAPHICS program (XVII Centurion. Ver. 17.2.00, StatPoint, Inc., Herndon, VA, USA). Also, compression-bending data with or without fatigue tests were analyzed by analysis of variance (ANOVA). Significant differences were observed (<italic>p</italic> &#x02264; 0.05) by the <italic>F</italic>-test for both comparisons.</p></sec></sec>
<sec sec-type="results" id="s3">
<title>Results</title>
<sec>
<title>Mechanical Testing of 3D-Printed PEEK Samples</title>
<p>Tensile strength, Young&#x00027;s modulus, and bending strength of the DB- and RB- samples, as described in section 2.5.1, were 36&#x02013;52 MPa, 2.1&#x02013;2.9 GPa, and 46&#x02013;70 MPa, respectively. These results were compared with those of Ti, 316L-SS, bulk PEEK, and canine tibiae obtained from the literature. 3D-printed PEEK exhibited a reduction of tensile strength of 2- to 16-fold compared with the other materials. Comparing 3D-printed PEEK with bulk PEEK, the reduction was 2.5-fold. Young&#x00027;s modulus of 3D-printed PEEK was closer to that of bone than to that of metal. 3D-printed PEEK was 0.2-fold inferior to that of bone, while 316L-SS and Ti alloys exhibited Young&#x00027;s modulus 9- and 16-fold higher, respectively (<xref ref-type="supplementary-material" rid="SM1">Supplementary File 1</xref>).</p>
<p>3D-printed PEEK exhibited a reduction of bending strength of 1.9- to 12.2-fold compared with that of other materials. Additionally, its bending strength was closer to that of bone than to that of metal, especially compared to Ti.</p></sec>
<sec>
<title>Mechanical Testing of the Endoprosthesis</title>
<sec>
<title>Mechanical Testing of the Non-inserted Endoprosthesis</title>
<p>In all the bending tests, the endoprosthesis remained intact, while the steel rod showed plastic deformation. In the compression tests, the failure occurred between the umbrella and stem of the endoprosthesis, with a maximum load of 936 &#x000B1; 199 N (<xref ref-type="supplementary-material" rid="SM2">Supplementary File 2</xref>).</p></sec>
<sec>
<title>Compression-Bending and Pure Compression Testing of the Endoprosthesis-Tibia Construct</title>
<p>The compression-bending test (67&#x000B0;) was assessed for the 15 ET-samples (<xref ref-type="supplementary-material" rid="SM3">Supplementary File 3</xref>). The tested samples showed two different types of failure. In eight of them, the endoprosthesis broke, leading to a force-displacement graph with a first peak load due to endoprosthesis failure and a second peak that indicates the fracture of the tibia (<xref ref-type="fig" rid="F7">Figures 7A,C</xref>). The bone failure occurred in the seven remaining samples, without any damage to the endoprosthesis after testing. In these cases, the force-displacement curves only showed the peak of the tibia fracture (<xref ref-type="fig" rid="F7">Figures 7B,D</xref>). Considering only the breaking data of the eight endoprostheses, the average failure force is 785 &#x000B1; 101 N. The calculated FoS was 2.6 &#x000B1; 0.3 for ET-samples at the compression&#x02013;bending test.</p>
<fig id="F7" position="float">
<label>Figure 7</label>
<caption><p><bold>(A,C)</bold> show force-displacement curve and ET-samples after endoprosthesis failure in a long tibia. <bold>(B,D)</bold> show force-displacement curve and ET-samples after bone failure in a short tibia. Compression-bending test of the tibia-endoprosthesis constructs at 67&#x000B0; to the ground.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fvets-09-887676-g0007.tif"/>
</fig>
<p>The results of the pure compression test reached a maximum force of 1,642 &#x000B1; 447 N before failure (<xref ref-type="supplementary-material" rid="SM2">Supplementary File 2</xref>). For higher forces, the endoprostheses failed between the umbrella and distal tibia (<xref ref-type="fig" rid="F8">Figure 8</xref>). The calculated FoS was 5.8 &#x000B1; 1.4 for ET-samples at pure compression.</p>
<fig id="F8" position="float">
<label>Figure 8</label>
<caption><p>Failure example of the tibia-endoprosthesis constructs observed after pure compression test.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fvets-09-887676-g0008.tif"/>
</fig></sec></sec>
<sec>
<title>Fatigue Testing of the Endoprosthesis-Tibia Construct at 67&#x000B0;</title>
<p>Upon fatigue test, the assessed ET-samples reached 500,000 cycles without failure. To analyze the effect of fatigue, the survivor samples were evaluated for failure by means of the quasistatic compression-bending test described in section 2.5.3. The samples could stand 764 &#x000B1; 62 N upon static compression-bending test after fatigue before breaking (<xref ref-type="supplementary-material" rid="SM3">Supplementary File 3</xref>). No statically significant differences were observed between the maximum force at the compression&#x02013;bending test with or without the previous fatigue test with a <italic>p</italic> &#x02264; 0.05. The calculated FoS was 2.5 &#x000B1; 0.2 for ET-samples at the compression&#x02013;bending test after fatigue.</p></sec></sec>
<sec sec-type="discussion" id="s4">
<title>Discussion</title>
<p>The 3D-printed endoprosthetic element can withstand normal weight-bearing loads reported in dogs at walk and trot. Additionally, we demonstrate that the behavior of the construct with acute loading to failure is not significantly different if the endoprosthesis is pre-fatigued with 500,000 cycles of pre-loading. The PEEK part of the endoprosthesis bore higher flexion and compression forces than canine tibiae during galloping (<xref ref-type="bibr" rid="B26">26</xref>, <xref ref-type="bibr" rid="B30">30</xref>). All obtained results during our tests were more than two times the vertical load that the endoprosthesis will have to support during the life of the canine. Thus, PEEK could be an interesting option for weight-bearing implants in quadrupedal animals because a single limb would support the entire weight of the animal.</p>
<p>The ET-samples showed a maximum load at failure of more than 2-fold the selected working load (300 N for a 20 kg dog) in the compression&#x02013;bending test. These results are even more promising considering that we only used a wet canine tibia without the remaining skeletal system components of the pelvic limb. Besides, we are comparing compression-bending results with the force borne by the whole pelvic limb, which is another handicap for the studied endoprosthesis. In addition, it should be considered that the compression-bending tests were carried out in a standing-like position, imitating the canine stifle angle (<xref ref-type="bibr" rid="B38">38</xref>). It means that the endoprosthesis suffered bending and compression load, at the same time, during our compression-bending test. Taking into consideration that all tibiae had a medullary canal of 9 mm and the inserted endoprostheses had the same size, two types of failure have been described in the ET-samples during this test. In eight samples, failure occurred in both the prosthesis and bone, and in seven samples, the endoprosthesis remained intact while bone failure occurred. These failure modes could be explained due to the lengths of the assessed tibiae. Thus, if the ET-sample is considered as a cantilever, with more bone length, more bending moments would suffer the endo-prosthesis (<xref ref-type="bibr" rid="B9">9</xref>). Thus, in longer tibiae, both failure of bone and the PEEK part will be expected. We can confirm that these facts are disadvantages for the endoprosthesis because, during the bending test of the E-samples, the PEEK part remained intact while the steel rod showed plastic deformation.</p>
<p>The fatigue test shows the long-term behavior of a device. The results of fatigue and the following compression-bending test indicate that the endoprosthesis can withstand 500,000 cycles with a trotting-like frequency and the total BW during galloping without detriment of its strength. The fatigue parameters, cycles, and frequencies were set based on other papers where fatigue resistance was evaluated for different metal implants (<xref ref-type="bibr" rid="B32">32</xref>, <xref ref-type="bibr" rid="B33">33</xref>) and assuming that trotting is the dog&#x00027;s pace with more step frequency. These test conditions were considered the most unfavorable scenario. No significant differences were observed between the maximum force at the compression&#x02013;bending test with or without the previous fatigue test. Therefore, the FoS after fatigue indicated that the endoprosthesis designed for this work would not experience dangerous levels of load during normal activity.</p>
<p>Pure compression results confirm that force-bearing data from only pure compression of the E-samples or from pure compression of ET-samples are significantly different. The ET-samples could stand 1,642 &#x000B1; 447 N on pure compression (5-fold increase in the dog&#x00027;s weight-bearing), in contrast to 936 &#x000B1; 199 N in the E-samples. This means that the endoprosthesis has better results in an environment closer to a real one, such as using wet bones (<xref ref-type="bibr" rid="B46">46</xref>) as receptacles for the endoprosthesis. Bone is considered an anisotropic material that has different elastic behavior and strength according to the percentage of humidity, the forces applied, and the force speed application (<xref ref-type="bibr" rid="B46">46</xref>&#x02013;<xref ref-type="bibr" rid="B48">48</xref>). Thus, achieving a test environment close to a real situation for medical application is essential for bone. Likewise, this increase in force-bearing results was because of the lateral compression exerted by the tibia during the endoprosthesis since part of the load applied to the endoprosthesis is transmitted to the tibia.</p>
<p>When a 3D printer is used to obtain solid pieces, the resultant material shows anisotropic behavior (<xref ref-type="bibr" rid="B49">49</xref>). Therefore, the 3D-printed PEEK properties will be different in each direction and will depend on the printing conditions. For this reason, mechanical characterization was carried out on 3D-printed PEEK samples (under the same printing conditions as the endoprostheses) to determine the mechanical properties of the PEEK material used for the endoprosthesis and to compare them with those of the tibiae. The differences observed in the mechanical properties between 3D-printed PEEK and bulk PEEK are due to the small spaces between the printed layers, which is typical in FDM technology, and to the infill parameter of 50% for the dog bone shape samples. This infill parameter was the same as that of the endoprostheses, which causes a drop in the mechanical properties (<xref ref-type="bibr" rid="B49">49</xref>) of 3D-printed PEEK. Nevertheless, its elasticity was still within canine cortical bone ranges and closer than those of metallic materials (<xref ref-type="bibr" rid="B21">21</xref>, <xref ref-type="bibr" rid="B22">22</xref>). Young&#x00027;s modulus especially was in the same order of magnitude as that of bone. In addition, the tensile and bending strengths of 3D-printed PEEK are enough to guarantee that the endoprosthesis will deform similarly to the bone. Besides, the lower stiffness and strength of 3D-printed PEEK with respect to that of bone allows for a good transfer of the loads from the implant to the tibia, minimizing the probability of peri-implant bone loss due to stress-shielding (<xref ref-type="bibr" rid="B7">7</xref>, <xref ref-type="bibr" rid="B10">10</xref>, <xref ref-type="bibr" rid="B42">42</xref>). Also, using no annealed 3D-printed PEEK permits anisotropic material behavior (<xref ref-type="bibr" rid="B22">22</xref>, <xref ref-type="bibr" rid="B23">23</xref>, <xref ref-type="bibr" rid="B49">49</xref>). This makes the force transmission between PEEK and bone more interesting because putting two anisotropic materials in contact with a similar elastic modulus and transmitting the bearing forces through them could be a potential solution to the stress-shielding phenomenon. In addition, the interaction of PEEK and canine tibia can be evaluated by comprehending the mechanical characterization of 3D-printed PEEK, mechanical properties of the canine tibia, and force-bearing results of pure compression of ET-samples. The interaction of two materials with similar elastic properties, such as PEEK and canine tibia, made a similar deformation of both materials. Once the endoprosthesis is inserted on the tibia, it adapts its shape to the medullary canal. This deformation would allow the reduction or elimination of dead spaces between the internal part of the exo-endoprosthesis and the bone. This PEEK-bone interface seems to permit a better stress transmission, as pure compression data of ET-samples had been probed. This increment of stress transmission would reduce the possibilities of stress-shielding phenomenon in a real situation. Nonetheless, more studies about it should be done.</p>
<p>In conclusion, the evaluated endoprosthetic part of an exo-endoprosthesis can largely withstand a dog&#x00027;s weight during a galloping pace and at a higher frequency than this pace without detriment to its maximum weight-bearing. This makes the 3D-printed PEEK exo-endoprostheses a suitable mechanical choice for medical devices in veterinary medicine.</p></sec>
<sec sec-type="data-availability" id="s5">
<title>Data Availability Statement</title>
<p>The original contributions presented in the study are included in the article/<xref ref-type="supplementary-material" rid="SM1">Supplementary Material</xref>, further inquiries can be directed to the corresponding author.</p></sec>
<sec id="s6">
<title>Author Contributions</title>
<p>Conceptualization: RM-D, YB, JR-R, and JR-Q. Data curation, methodology, resources, and writing&#x02014;original draft: RM-D, YB, and JR-R. Formal analysis and validation: RM-D and JR-R. Funding acquisition and project administration: JR-Q and SP-F. Investigation: RM-D, YB, JR-R, and EP. Software: RM-D, SP-F, EP, YB, and JR-R. Supervision: JR-Q, SP-F, and JR-R. Writing&#x02014;review and editing: RM-D, YB, JR-R, and JR-Q. All authors contributed to the article and approved the submitted version.</p></sec>
<sec sec-type="funding-information" id="s7">
<title>Funding</title>
<p>This work was supported by the regional government of Madrid, Spain [Grant IND2017/BMD-7726]. RM-D received a PhD fellowship from this grant. The regional government of Madrid was not involved in any decision about the development of this study.</p>
</sec>
<sec sec-type="COI-statement" id="conf1">
<title>Conflict of Interest</title>
<p>RM-D and SP-F were employed by ABAX Innovation Technologies. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p></sec>
<sec sec-type="disclaimer" id="s8">
<title>Publisher&#x00027;s Note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p></sec> </body>
<back>
<ack><p>We would like to thank Abax Innovation Technologies and the Veterinary Anatomy and Embryology Department of the Faculty of Veterinary Medicine at Complutense University of Madrid for their technical support and knowledge. In addition, we are sincerely thankful to all the people of the Industrial Testing Laboratory at the ICAI School of Engineering of Comillas Pontifical University, especially to Gonzalo Garc&#x000ED;a Gal&#x000E1;n and Susana Guzm&#x000E1;n.</p>
</ack><sec sec-type="supplementary-material" id="s9">
<title>Supplementary Material</title>
<p>The Supplementary Material for this article can be found online at: <ext-link ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/fvets.2022.887676/full#supplementary-material">https://www.frontiersin.org/articles/10.3389/fvets.2022.887676/full#supplementary-material</ext-link></p>
<supplementary-material xlink:href="Table_1.XLSX" id="SM1" mimetype="application/vnd.openxmlformats-officedocument.spreadsheetml.sheet" xmlns:xlink="http://www.w3.org/1999/xlink">
<label>Supplementary File 1</label>
<caption><p>PEEK_tests.xlsx. Tested 3D-printed PEEK samples and their corresponding dimensions and strength results are shown. Characteristics of the tests, mean and standard deviation (SD) are also described.</p></caption> </supplementary-material>
<supplementary-material xlink:href="Table_2.XLSX" id="SM2" mimetype="application/vnd.openxmlformats-officedocument.spreadsheetml.sheet" xmlns:xlink="http://www.w3.org/1999/xlink">
<label>Supplementary File 2</label>
<caption><p>Compression_Tests.xlsx. Strength results of the endoprosthesis and bone-endoprosthesis assembly are described. Also, characteristics of the tests, mean, and standard deviation (SD) are also described.</p></caption> </supplementary-material>
<supplementary-material xlink:href="Table_3.XLSX" id="SM3" mimetype="application/vnd.openxmlformats-officedocument.spreadsheetml.sheet" xmlns:xlink="http://www.w3.org/1999/xlink">
<label>Supplementary File 3</label>
<caption><p>C-B_Tests.xlsx. Number of ET-samples and their corresponding results at compression-bending test before and after fatigue test are shown. Also, characteristics of the tests, mean, and standard deviation (SD) are also described.</p></caption> </supplementary-material></sec>
<ref-list>
<title>References</title>
<ref id="B1">
<label>1.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Thesleff</surname> <given-names>A</given-names></name> <name><surname>Br&#x000E5;nemark</surname> <given-names>R</given-names></name> <name><surname>H&#x000E5;kansson</surname> <given-names>B</given-names></name> <name><surname>Ortiz-Catalan</surname> <given-names>M</given-names></name></person-group>. <article-title>Biomechanical characterisation of bone-anchored implant systems for amputation limb prostheses: a systematic review</article-title>. <source>Ann Biomed Eng.</source> (<year>2018</year>) <volume>46</volume>:<fpage>377</fpage>&#x02013;<lpage>91</lpage>. <pub-id pub-id-type="doi">10.1007/s10439-017-1976-4</pub-id><pub-id pub-id-type="pmid">29327257</pub-id></citation></ref>
<ref id="B2">
<label>2.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fitzpatrick</surname> <given-names>N</given-names></name> <name><surname>Smith</surname> <given-names>TJ</given-names></name> <name><surname>Pendegrass</surname> <given-names>CJ</given-names></name> <name><surname>Yeadon</surname> <given-names>R</given-names></name> <name><surname>Ring</surname> <given-names>M</given-names></name> <name><surname>Goodship</surname> <given-names>AE</given-names></name> <etal/></person-group>. <article-title>Intraosseous Transcutaneous Amputation Prosthesis (ITAP) for limb salvage in 4 dogs</article-title>. <source>Vet Surg</source>. (<year>2011</year>) <volume>40</volume>:<fpage>909</fpage>&#x02013;<lpage>25</lpage>. <pub-id pub-id-type="doi">10.1111/j.1532-950X.2011.00891.x</pub-id><pub-id pub-id-type="pmid">22092391</pub-id></citation></ref>
<ref id="B3">
<label>3.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Farrell</surname> <given-names>BJ</given-names></name> <name><surname>Prilutsky</surname> <given-names>BI</given-names></name> <name><surname>Kistenberg</surname> <given-names>RS</given-names></name> <name><surname>Dalton</surname> <given-names>JF</given-names></name> <name><surname>Pitkin</surname> <given-names>M</given-names></name></person-group>. <article-title>An animal model to evaluate skin&#x02013;implant&#x02013;bone integration and gait with a prosthesis directly attached to the residual limb</article-title>. <source>Clin Biomech.</source> (<year>2014</year>) <volume>29</volume>:<fpage>336</fpage>&#x02013;<lpage>49</lpage>. <pub-id pub-id-type="doi">10.1016/j.clinbiomech.2013.12.014</pub-id><pub-id pub-id-type="pmid">24405567</pub-id></citation></ref>
<ref id="B4">
<label>4.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Drygas</surname> <given-names>KA</given-names></name> <name><surname>Taylor</surname> <given-names>R</given-names></name> <name><surname>Sidebotham</surname> <given-names>CG</given-names></name> <name><surname>Hugate</surname> <given-names>RR</given-names></name> <name><surname>Mcalexander</surname> <given-names>H</given-names></name></person-group>. <article-title>Transcutaneous tibial implants: a surgical procedure for restoring ambulation after amputation of the distal aspect of the tibia in a dog</article-title>. <source>Vet Surg.</source> (<year>2008</year>) <volume>37</volume>:<fpage>322</fpage>&#x02013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1111/j.1532-950X.2008.00384.x</pub-id><pub-id pub-id-type="pmid">18564255</pub-id></citation></ref>
<ref id="B5">
<label>5.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>DeVasConCellos</surname> <given-names>P</given-names></name> <name><surname>Balla</surname> <given-names>VK</given-names></name> <name><surname>Bose</surname> <given-names>S</given-names></name> <name><surname>Fugazzi</surname> <given-names>R</given-names></name> <name><surname>Dernell</surname> <given-names>WS</given-names></name> <name><surname>Bandyopadhyay</surname> <given-names>A</given-names></name></person-group>. <article-title>Patient specific implants for amputation prostheses: design, manufacture and analysis</article-title>. <source>Vet Comp Orthop Traumatol.</source> (<year>2012</year>) <volume>25</volume>:<fpage>286</fpage>&#x02013;<lpage>96</lpage>. <pub-id pub-id-type="doi">10.3415/VCOT-11-03-0043</pub-id><pub-id pub-id-type="pmid">22580779</pub-id></citation></ref>
<ref id="B6">
<label>6.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Golachowski</surname> <given-names>A</given-names></name> <name><surname>Al Ghabri</surname> <given-names>MR</given-names></name> <name><surname>Golachowska</surname> <given-names>B</given-names></name> <name><surname>Al Abri</surname> <given-names>H</given-names></name> <name><surname>Lubak</surname> <given-names>M</given-names></name> <name><surname>Sujeta</surname> <given-names>M</given-names></name></person-group>. <article-title>Implantation of an intraosseous transcutaneous amputation prosthesis restoring ambulation after amputation of the distal aspect of the left tibia in an arabian Tahr (Arabitragus jayakari)</article-title>. <source>Front Vet Sci.</source> (<year>2019</year>) <volume>6</volume>:<fpage>182</fpage>. <pub-id pub-id-type="doi">10.3389/fvets.2019.00182</pub-id><pub-id pub-id-type="pmid">31245397</pub-id></citation></ref>
<ref id="B7">
<label>7.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Huiskes</surname> <given-names>R</given-names></name> <name><surname>Weinans</surname> <given-names>H</given-names></name> <name><surname>Rietbergen</surname> <given-names>BV</given-names></name></person-group>. <article-title>The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials</article-title>. <source>Clin Orthop Relat Res</source>. (<year>1992</year>) <volume>274</volume>:<fpage>124</fpage>&#x02013;<lpage>34</lpage>. <pub-id pub-id-type="doi">10.1097/00003086-199201000-00014</pub-id><pub-id pub-id-type="pmid">1728998</pub-id></citation></ref>
<ref id="B8">
<label>8.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wooley</surname> <given-names>P</given-names></name> <name><surname>Schwarz</surname> <given-names>E</given-names></name></person-group>. <article-title>Aseptic loosening</article-title>. <source>Gene Ther.</source> (<year>2004</year>) <volume>11</volume>:<fpage>402</fpage>&#x02013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1038/sj.gt.3302202</pub-id><pub-id pub-id-type="pmid">14724679</pub-id></citation></ref>
<ref id="B9">
<label>9.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sharir</surname> <given-names>A</given-names></name> <name><surname>Barak</surname> <given-names>MM</given-names></name> <name><surname>Shahar</surname> <given-names>R</given-names></name></person-group>. <article-title>Whole bone mechanics and mechanical testing</article-title>. <source>Vet J.</source> (<year>2008</year>) <volume>177</volume>:<fpage>8</fpage>&#x02013;<lpage>17</lpage>. <pub-id pub-id-type="doi">10.1016/j.tvjl.2007.09.012</pub-id><pub-id pub-id-type="pmid">17986396</pub-id></citation></ref>
<ref id="B10">
<label>10.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sumner</surname> <given-names>DR</given-names></name></person-group>. <article-title>Long-term implant fixation and stress-shielding in total hip replacement</article-title>. <source>J Biomech.</source> (<year>2015</year>) <volume>48</volume>:<fpage>797</fpage>&#x02013;<lpage>800</lpage>. <pub-id pub-id-type="doi">10.1016/j.jbiomech.2014.12.021</pub-id><pub-id pub-id-type="pmid">25579990</pub-id></citation></ref>
<ref id="B11">
<label>11.</label>
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Kurtz</surname> <given-names>SM</given-names></name></person-group>. <source>PEEK Biomaterials Handbook</source>. <edition>2nd ed.</edition> <publisher-loc>Amsterdam</publisher-loc>: <publisher-name>Elsevier</publisher-name> (<year>2019</year>). p. 465.</citation>
</ref>
<ref id="B12">
<label>12.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mat&#x000E9; S&#x000E1;nchez de Val</surname> <given-names>JE</given-names></name> <name><surname>G&#x000F3;mez-Moreno</surname> <given-names>G</given-names></name> <name><surname>P&#x000E9;rez-Albacete Mart&#x000ED;nez</surname> <given-names>C</given-names></name> <name><surname>Ram&#x000ED;rez-Fern&#x000E1;ndez</surname> <given-names>MP</given-names></name> <name><surname>Granero-Mar&#x000ED;n</surname> <given-names>JM</given-names></name> <name><surname>Gehrke</surname> <given-names>SA</given-names></name> <etal/></person-group>. <article-title>Peri-implant tissue behavior around non-titanium material: experimental study in dogs</article-title>. <source>Ann Anat.</source> (<year>2016</year>) <volume>206</volume>:<fpage>104</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1016/j.aanat.2016.03.005</pub-id><pub-id pub-id-type="pmid">27045596</pub-id></citation></ref>
<ref id="B13">
<label>13.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wang</surname> <given-names>N</given-names></name> <name><surname>Xie</surname> <given-names>H</given-names></name> <name><surname>Xi</surname> <given-names>C</given-names></name> <name><surname>Zhang</surname> <given-names>H</given-names></name> <name><surname>Yan</surname> <given-names>J</given-names></name></person-group>. <article-title>A study to compare the efficacy of polyether ether ketone rod device with titanium devices in posterior spinal fusion in a canine model</article-title>. <source>J Orthop Surg Res.</source> (<year>2017</year>) <volume>12</volume>:<fpage>40</fpage>. <pub-id pub-id-type="doi">10.1186/s13018-017-0543-x</pub-id><pub-id pub-id-type="pmid">28279204</pub-id></citation></ref>
<ref id="B14">
<label>14.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Shimizu</surname> <given-names>T</given-names></name> <name><surname>Fujibayashi</surname> <given-names>S</given-names></name> <name><surname>Yamaguchi</surname> <given-names>S</given-names></name> <name><surname>Otsuki</surname> <given-names>B</given-names></name> <name><surname>Okuzu</surname> <given-names>Y</given-names></name> <name><surname>Matsushita</surname> <given-names>T</given-names></name> <etal/></person-group>. <article-title><italic>In vivo</italic> experimental study of anterior cervical fusion using bioactive polyetheretherketone in a canine model</article-title>. <source>PLoS ONE.</source> (<year>2017</year>) <volume>12</volume>:<fpage>e0184495</fpage>. <pub-id pub-id-type="doi">10.1371/journal.pone.0184495</pub-id><pub-id pub-id-type="pmid">28886118</pub-id></citation></ref>
<ref id="B15">
<label>15.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Atzeni</surname> <given-names>E</given-names></name> <name><surname>Salmi</surname> <given-names>A</given-names></name></person-group>. <article-title>Economics of additive manufacturing for end-usable metal parts</article-title>. <source>Int J Adv Manuf Technol.</source> (<year>2012</year>) <volume>62</volume>:<fpage>1147</fpage>&#x02013;<lpage>55</lpage>. <pub-id pub-id-type="doi">10.1007/s00170-011-3878-1</pub-id><pub-id pub-id-type="pmid">33268812</pub-id></citation></ref>
<ref id="B16">
<label>16.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hopkinson</surname> <given-names>N</given-names></name> <name><surname>Dicknes</surname> <given-names>P</given-names></name></person-group>. <article-title>Analysis of rapid manufacturing&#x02014;using layer manufacturing processes for production</article-title>. <source>Proc Inst Mech Eng C J Mech Eng Sci.</source> (<year>2003</year>) <volume>217</volume>:<fpage>31</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1243/095440603762554596</pub-id><pub-id pub-id-type="pmid">16808067</pub-id></citation></ref>
<ref id="B17">
<label>17.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Popov</surname> <given-names>VV</given-names></name> <name><surname>Muller-Kamskii</surname> <given-names>G</given-names></name> <name><surname>Katz-Demyanetz</surname> <given-names>A</given-names></name> <name><surname>Kovalevsky</surname> <given-names>A</given-names></name> <name><surname>Usov</surname> <given-names>S</given-names></name> <name><surname>Trofimcow</surname> <given-names>D</given-names></name> <etal/></person-group>. <article-title>Additive manufacturing to veterinary practice: recovery of bony defects after the osteosarcoma resection in canines</article-title>. <source>Biomed Eng Lett.</source> (<year>2019</year>) <volume>9</volume>:<fpage>97</fpage>&#x02013;<lpage>108</lpage>. <pub-id pub-id-type="doi">10.1007/s13534-018-00092-7</pub-id><pub-id pub-id-type="pmid">30956883</pub-id></citation></ref>
<ref id="B18">
<label>18.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bray</surname> <given-names>JP</given-names></name> <name><surname>Kersley</surname> <given-names>A</given-names></name> <name><surname>Downing</surname> <given-names>W</given-names></name> <name><surname>Crosse</surname> <given-names>KR</given-names></name> <name><surname>Worth</surname> <given-names>AJ</given-names></name> <name><surname>House</surname> <given-names>AK</given-names></name> <etal/></person-group>. <article-title>Clinical outcomes of patient-specific porous titanium endoprostheses in dogs with tumors of the mandible, radius, or tibia: 12 cases (2013&#x02013;2016)</article-title>. <source>J Am Vet Med Assoc.</source> (<year>2017</year>) <volume>251</volume>:<fpage>566</fpage>&#x02013;<lpage>79</lpage>. <pub-id pub-id-type="doi">10.2460/javma.251.5.566</pub-id><pub-id pub-id-type="pmid">28828951</pub-id></citation></ref>
<ref id="B19">
<label>19.</label>
<citation citation-type="web"><person-group person-group-type="author"><name><surname>Mendaza De Cal</surname> <given-names>RM</given-names></name> <name><surname>Peso Fern&#x000E1;ndez</surname> <given-names>S</given-names></name> <name><surname>Rodr&#x000ED;guez Quir&#x000F3;s</surname> <given-names>J</given-names></name></person-group>. <article-title>Endopr&#x000F3;tesis a medida para huesos largos de animales</article-title> (<year>2020</year>). Available online at: <ext-link ext-link-type="uri" xlink:href="https://patentimages.storage.googleapis.com/0c/f4/54/d74e23ec379b45/ES2736410A1.pdf">https://patentimages.storage.googleapis.com/0c/f4/54/d74e23ec379b45/ES2736410A1.pdf</ext-link> (accessed April 27, 2020).</citation>
</ref>
<ref id="B20">
<label>20.</label>
<citation citation-type="book"><person-group person-group-type="author"><collab>Steven Lathers Jeffrey La Belle</collab></person-group>. <article-title>Osseointegratable prosthetic device and manufacturing method</article-title>. US 2018/0049897 Al, 2018. p. 49.</citation>
</ref>
<ref id="B21">
<label>21.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Arif</surname> <given-names>MF</given-names></name> <name><surname>Kumar</surname> <given-names>S</given-names></name> <name><surname>Varadarajan</surname> <given-names>KM</given-names></name> <name><surname>Cantwell</surname> <given-names>WJ</given-names></name></person-group>. <article-title>Performance of biocompatible PEEK processed by fused deposition additive manufacturing</article-title>. <source>Mater Des.</source> (<year>2018</year>) <volume>146</volume>:<fpage>249</fpage>&#x02013;<lpage>59</lpage>. <pub-id pub-id-type="doi">10.1016/j.matdes.2018.03.015</pub-id></citation>
</ref>
<ref id="B22">
<label>22.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wu</surname> <given-names>WZ</given-names></name> <name><surname>Geng</surname> <given-names>P</given-names></name> <name><surname>Zhao</surname> <given-names>J</given-names></name> <name><surname>Zhang</surname> <given-names>Y</given-names></name> <name><surname>Rosen</surname> <given-names>DW</given-names></name> <name><surname>Zhang</surname> <given-names>HB</given-names></name></person-group>. <article-title>Manufacture and thermal deformation analysis of semicrystalline polymer polyether ether ketone by 3D printing</article-title>. <source>Mat Res Innov</source>. (<year>2014</year>) 18:S5-12&#x02013;6. <pub-id pub-id-type="doi">10.1179/1432891714Z.000000000898</pub-id></citation>
</ref>
<ref id="B23">
<label>23.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yang</surname> <given-names>C</given-names></name> <name><surname>Tian</surname> <given-names>X</given-names></name> <name><surname>Li</surname> <given-names>D</given-names></name> <name><surname>Cao</surname> <given-names>Y</given-names></name> <name><surname>Zhao</surname> <given-names>F</given-names></name> <name><surname>Shi</surname> <given-names>C</given-names></name></person-group>. <article-title>Influence of thermal processing conditions in 3D printing on the crystallinity and mechanical properties of PEEK material</article-title>. <source>J Mat Process Technol.</source> (<year>2017</year>) <volume>248</volume>:<fpage>1</fpage>&#x02013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1016/j.jmatprotec.2017.04.027</pub-id></citation>
</ref>
<ref id="B24">
<label>24.</label>
<citation citation-type="book"><source>Plastics&#x02014;Determination of Tensile Properties. Part 1: General Principles</source>. Report No.: ISO 527-1:2019. <publisher-loc>Geneva</publisher-loc>: <publisher-name>International Organization for Standardization</publisher-name> (<year>2019</year>).</citation>
</ref>
<ref id="B25">
<label>25.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Voss</surname> <given-names>K</given-names></name> <name><surname>Wiestner</surname> <given-names>T</given-names></name> <name><surname>Galeandro</surname> <given-names>L</given-names></name> <name><surname>H&#x000E4;ssig</surname> <given-names>MR</given-names></name> <name><surname>Montavon</surname> <given-names>PM</given-names></name></person-group>. <article-title>Effect of dog breed and body conformation on vertical ground reaction forces, impulses, and stance times</article-title>. <source>Vet Comp Orthop Traumatol.</source> (<year>2011</year>) <volume>24</volume>:<fpage>106</fpage>&#x02013;<lpage>12</lpage>. <pub-id pub-id-type="doi">10.3415/VCOT-10-06-0098</pub-id><pub-id pub-id-type="pmid">21243175</pub-id></citation></ref>
<ref id="B26">
<label>26.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Walter</surname> <given-names>RM</given-names></name> <name><surname>Carrier</surname> <given-names>DR</given-names></name></person-group>. <article-title>Ground forces applied by galloping dogs</article-title>. <source>J Exp Biol.</source> (<year>2007</year>) <volume>210</volume>:<fpage>208</fpage>&#x02013;<lpage>16</lpage>. <pub-id pub-id-type="doi">10.1242/jeb.02645</pub-id><pub-id pub-id-type="pmid">17210958</pub-id></citation></ref>
<ref id="B27">
<label>27.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Colborne</surname> <given-names>GR</given-names></name> <name><surname>Walker</surname> <given-names>AM</given-names></name> <name><surname>Tattersall</surname> <given-names>AJ</given-names></name> <name><surname>Fuller</surname> <given-names>CJ</given-names></name></person-group>. <article-title>Effect of trotting velocity on work patterns of the hind limbs of Greyhounds</article-title>. <source>Am J Vet Res.</source> (<year>2006</year>) <volume>67</volume>:<fpage>1293</fpage>&#x02013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.2460/ajvr.67.8.1293</pub-id><pub-id pub-id-type="pmid">16881839</pub-id></citation></ref>
<ref id="B28">
<label>28.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Corbee</surname> <given-names>RJ</given-names></name> <name><surname>Maas</surname> <given-names>H</given-names></name> <name><surname>Doornenbal</surname> <given-names>A</given-names></name> <name><surname>Hazewinkel</surname> <given-names>HAW</given-names></name></person-group>. <article-title>Forelimb and hindlimb ground reaction forces of walking cats: assessment and comparison with walking dogs</article-title>. <source>Vet J.</source> (<year>2014</year>) <volume>202</volume>:<fpage>116</fpage>&#x02013;<lpage>27</lpage>. <pub-id pub-id-type="doi">10.1016/j.tvjl.2014.07.001</pub-id><pub-id pub-id-type="pmid">25155217</pub-id></citation></ref>
<ref id="B29">
<label>29.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Schwarz</surname> <given-names>N</given-names></name> <name><surname>Tichy</surname> <given-names>A</given-names></name> <name><surname>Peham</surname> <given-names>C</given-names></name> <name><surname>Bockstahler</surname> <given-names>B</given-names></name></person-group>. <article-title>Vertical force distribution in the paws of sound labrador retrievers during walking</article-title>. <source>Vet J.</source> (<year>2017</year>) <volume>221</volume>:<fpage>16</fpage>&#x02013;<lpage>22</lpage>. <pub-id pub-id-type="doi">10.1016/j.tvjl.2017.01.014</pub-id><pub-id pub-id-type="pmid">28283074</pub-id></citation></ref>
<ref id="B30">
<label>30.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Walter</surname> <given-names>RM</given-names></name> <name><surname>Carrier</surname> <given-names>DR</given-names></name></person-group>. <article-title>Rapid acceleration in dogs: ground forces and body posture dynamics</article-title>. <source>J Exp Biol.</source> (<year>2009</year>) <volume>212</volume>:<fpage>1930</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1242/jeb.023762</pub-id><pub-id pub-id-type="pmid">19483011</pub-id></citation></ref>
<ref id="B31">
<label>31.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Krotscheck</surname> <given-names>U</given-names></name> <name><surname>Todhunter</surname> <given-names>RJ</given-names></name> <name><surname>Nelson</surname> <given-names>SA</given-names></name> <name><surname>Sutter</surname> <given-names>NB</given-names></name> <name><surname>Mohammed</surname> <given-names>HO</given-names></name></person-group>. <article-title>Precision and accuracy of ground reaction force normalization in a heterogeneous population of dogs: ground reaction force normalization</article-title>. <source>Vet Surg.</source> (<year>2014</year>) <volume>43</volume>:<fpage>437</fpage>&#x02013;<lpage>45</lpage>. <pub-id pub-id-type="doi">10.1111/j.1532-950X.2014.12176.x</pub-id><pub-id pub-id-type="pmid">24702543</pub-id></citation></ref>
<ref id="B32">
<label>32.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Schmierer</surname> <given-names>PA</given-names></name> <name><surname>Smolders</surname> <given-names>LA</given-names></name> <name><surname>Zderic</surname> <given-names>I</given-names></name> <name><surname>Gueorguiev</surname> <given-names>B</given-names></name> <name><surname>Pozzi</surname> <given-names>A</given-names></name> <name><surname>Knell</surname> <given-names>SC</given-names></name></person-group>. <article-title>Biomechanical properties of plate constructs for feline ilial fracture gap stabilization</article-title>. <source>Vet Surg.</source> (<year>2019</year>) <volume>48</volume>:<fpage>88</fpage>&#x02013;<lpage>95</lpage>. <pub-id pub-id-type="doi">10.1111/vsu.13124</pub-id><pub-id pub-id-type="pmid">30422336</pub-id></citation></ref>
<ref id="B33">
<label>33.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chao</surname> <given-names>P</given-names></name> <name><surname>Conrad</surname> <given-names>BP</given-names></name> <name><surname>Lewis</surname> <given-names>DD</given-names></name> <name><surname>Horodyski</surname> <given-names>M</given-names></name></person-group>. <article-title>Pozzi A. Effect of plate working length on plate stiffness and cyclic fatigue life in a cadaveric femoral fracture gap model stabilized with a 12-hole 24 mm locking compression plate</article-title>. <source>BMC Vet Res.</source> (<year>2013</year>) <volume>9</volume>:<fpage>125</fpage>. <pub-id pub-id-type="doi">10.1186/1746-6148-9-125</pub-id><pub-id pub-id-type="pmid">23800317</pub-id></citation></ref>
<ref id="B34">
<label>34.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kim</surname> <given-names>J</given-names></name> <name><surname>Rietdyk</surname> <given-names>S</given-names></name> <name><surname>Breur</surname> <given-names>GJ</given-names></name></person-group>. <article-title>Comparison of two-dimensional and three-dimensional systems for kinematic analysis of the sagittal motion of canine hind limbs during walking</article-title>. <source>Am J Vet Res.</source> (<year>2008</year>) <volume>69</volume>:<fpage>1116</fpage>&#x02013;<lpage>22</lpage>. <pub-id pub-id-type="doi">10.2460/ajvr.69.9.1116</pub-id><pub-id pub-id-type="pmid">18764680</pub-id></citation></ref>
<ref id="B35">
<label>35.</label>
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Fischer</surname> <given-names>MS</given-names></name> <name><surname>Lilje</surname> <given-names>KE</given-names></name></person-group>. <article-title>Dogs in motion</article-title>. <edition>2nd ed.</edition> <publisher-loc>Paderborn</publisher-loc>: <publisher-name>VDH</publisher-name> (<year>2020</year>).p. 207.</citation>
</ref>
<ref id="B36">
<label>36.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mendaza-DeCal</surname> <given-names>R</given-names></name> <name><surname>Peso-Fernandez</surname> <given-names>S</given-names></name> <name><surname>Rodriguez-Quiros</surname> <given-names>J</given-names></name></person-group>. <article-title>Test of designing and manufacturing a polyether ether ketone endoprosthesis for canine extremities by 3D printing</article-title>. <source>Front Mech Eng.</source> (<year>2021</year>) <volume>7</volume>:<fpage>693436</fpage>. <pub-id pub-id-type="doi">10.3389/fmech.2021.693436</pub-id></citation>
</ref>
<ref id="B37">
<label>37.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Vaezi</surname> <given-names>M</given-names></name> <name><surname>Yang</surname> <given-names>S</given-names></name></person-group>. <article-title>Extrusion-based additive manufacturing of PEEK for biomedical applications</article-title>. <source>Virtual Phys Prototyp.</source> (<year>2015</year>) <volume>10</volume>:<fpage>123</fpage>&#x02013;<lpage>35</lpage>. <pub-id pub-id-type="doi">10.1080/17452759.2015.1097053</pub-id><pub-id pub-id-type="pmid">34077906</pub-id></citation></ref>
<ref id="B38">
<label>38.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Holler</surname> <given-names>PJ</given-names></name> <name><surname>Brazda</surname> <given-names>V</given-names></name> <name><surname>Dal-Bianco</surname> <given-names>B</given-names></name> <name><surname>Lewy</surname> <given-names>E</given-names></name> <name><surname>Mueller</surname> <given-names>MC</given-names></name> <name><surname>Peham</surname> <given-names>C</given-names></name> <etal/></person-group>. <article-title>Kinematic motion analysis of the joints of the forelimbs and hind limbs of dogs during walking exercise regimens</article-title>. <source>Am J Vet Res.</source> (<year>2010</year>) <volume>71</volume>:<fpage>734</fpage>&#x02013;<lpage>40</lpage>. <pub-id pub-id-type="doi">10.2460/ajvr.71.7.734</pub-id><pub-id pub-id-type="pmid">20594074</pub-id></citation></ref>
<ref id="B39">
<label>39.</label>
<citation citation-type="book"><person-group person-group-type="author"><collab>Manufacturing by additive of caps on plastics</collab></person-group>. <source>Additive Manufacturing. Preparation of Test Pieces</source>. Report No.: UNE 116005:2012. <publisher-loc>Madrid</publisher-loc>: <publisher-name>Asociaci&#x000F3;n Espa&#x000F1;ola de Normalizaci&#x000F3;n y Certificaci&#x000F3;n</publisher-name> (<year>2012</year>).</citation>
</ref>
<ref id="B40">
<label>40.</label>
<citation citation-type="book"><person-group person-group-type="author"><collab>Plastics&#x02014;Determination of Flexural Properties</collab></person-group>. <article-title>Report No</article-title>.: ISO 178:2019. <publisher-loc>Geneva</publisher-loc>: <publisher-name>International Organization for Standardization</publisher-name> (<year>2019</year>).</citation>
</ref>
<ref id="B41">
<label>41.</label>
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Swanson</surname> <given-names>J</given-names></name></person-group>. <source>Ansys Granta EdoPack Software</source>. <publisher-loc>Cambridge</publisher-loc>: <publisher-name>Ansys Inc</publisher-name>.</citation>
</ref>
<ref id="B42">
<label>42.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Geetha</surname> <given-names>M</given-names></name> <name><surname>Singh</surname> <given-names>AK</given-names></name> <name><surname>Asokamani</surname> <given-names>R</given-names></name> <name><surname>Gogia</surname> <given-names>AK</given-names></name></person-group>. <article-title>Ti based biomaterials, the ultimate choice for orthopaedic implants&#x02014;a review</article-title>. <source>Prog Mater Sci.</source> (<year>2009</year>) <volume>54</volume>:<fpage>397</fpage>&#x02013;<lpage>425</lpage>. <pub-id pub-id-type="doi">10.1016/j.pmatsci.2008.06.004</pub-id></citation>
</ref>
<ref id="B43">
<label>43.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dewidar</surname> <given-names>MM</given-names></name> <name><surname>Yoon</surname> <given-names>HC</given-names></name> <name><surname>Lim</surname> <given-names>JK</given-names></name></person-group>. <article-title>Mechanical properties of metals for biomedical applications using powder metallurgy process: a review</article-title>. <source>Met Mater Int.</source> (<year>2006</year>) <volume>12</volume>:<fpage>193</fpage>&#x02013;<lpage>206</lpage>. <pub-id pub-id-type="doi">10.1007/BF03027531</pub-id></citation>
</ref>
<ref id="B44">
<label>44.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Saha</surname> <given-names>S</given-names></name> <name><surname>Martin</surname> <given-names>DL</given-names></name> <name><surname>Phillips</surname> <given-names>A</given-names></name></person-group>. <article-title>Elastic and strength properties of canine long bones</article-title>. <source>Med Biol Eng Comput.</source> (<year>1977</year>) <volume>15</volume>:<fpage>72</fpage>&#x02013;<lpage>4</lpage>. <pub-id pub-id-type="doi">10.1007/BF02441578</pub-id><pub-id pub-id-type="pmid">194127</pub-id></citation></ref>
<ref id="B45">
<label>45.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kemp</surname> <given-names>TJ</given-names></name> <name><surname>Bachus</surname> <given-names>KN</given-names></name> <name><surname>Nairn</surname> <given-names>JA</given-names></name> <name><surname>Carrier</surname> <given-names>DR</given-names></name></person-group>. <article-title>Functional trade-offs in the limb bones of dogs selected for running <italic>versus</italic> fighting</article-title>. <source>J Exp Biol.</source> (<year>2005</year>) <volume>208</volume>:<fpage>3475</fpage>&#x02013;<lpage>82</lpage>. <pub-id pub-id-type="doi">10.1242/jeb.01814</pub-id><pub-id pub-id-type="pmid">16155220</pub-id></citation></ref>
<ref id="B46">
<label>46.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lee</surname> <given-names>KL</given-names></name> <name><surname>Sobieraj</surname> <given-names>M</given-names></name> <name><surname>Baldassarri</surname> <given-names>M</given-names></name> <name><surname>Gupta</surname> <given-names>N</given-names></name> <name><surname>Pinisetty</surname> <given-names>D</given-names></name> <name><surname>Janal</surname> <given-names>MN</given-names></name> <etal/></person-group>. <article-title>The effects of loading conditions and specimen environment on the nanomechanical response of canine cortical bone</article-title>. <source>Mater Sci Eng C.</source> (<year>2013</year>) <volume>33</volume>:<fpage>4582</fpage>&#x02013;<lpage>6</lpage>. <pub-id pub-id-type="doi">10.1016/j.msec.2013.07.018</pub-id><pub-id pub-id-type="pmid">24094163</pub-id></citation></ref>
<ref id="B47">
<label>47.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sammarco</surname> <given-names>GJ</given-names></name> <name><surname>Burstein</surname> <given-names>AH</given-names></name> <name><surname>Davis</surname> <given-names>WL</given-names></name> <name><surname>Frankel</surname> <given-names>VH</given-names></name></person-group>. <article-title>The biomechanics of torsional fractures: the effect of loading on ultimate properties</article-title>. <source>J Biomech.</source> (<year>1971</year>) <volume>4</volume>:<fpage>113</fpage>&#x02013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1016/0021-9290(71)90021-2</pub-id><pub-id pub-id-type="pmid">5119406</pub-id></citation></ref>
<ref id="B48">
<label>48.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sielman</surname> <given-names>E</given-names></name></person-group>. <article-title>Mechanical properties of long bones in dogs</article-title>. <source>Am J Vet Res.</source> (<year>1994</year>) <volume>55</volume>:<fpage>3</fpage>.<pub-id pub-id-type="pmid">7978660</pub-id></citation></ref>
<ref id="B49">
<label>49.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pu</surname> <given-names>J</given-names></name> <name><surname>McIlroy</surname> <given-names>C</given-names></name> <name><surname>Jones</surname> <given-names>A</given-names></name> <name><surname>Ashcroft</surname> <given-names>I</given-names></name></person-group>. <article-title>Understanding mechanical properties in fused filament fabrication of polyether ether ketone</article-title>. <source>Addit Manuf</source> . (<year>2020</year>) <volume>37</volume>:<fpage>101673</fpage>. <pub-id pub-id-type="doi">10.1016/j.addma.2020.101673</pub-id></citation>
</ref>
</ref-list>
</back>
</article>