<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Archiving and Interchange DTD v2.3 20070202//EN" "archivearticle.dtd">
<article article-type="methods-article" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xml:lang="EN">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Surg.</journal-id>
<journal-title>Frontiers in Surgery</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Surg.</abbrev-journal-title>
<issn pub-type="epub">2296-875X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fsurg.2024.1495251</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Surgery</subject>
<subj-group>
<subject>Methods</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Robotic pedicle screw placement for minimal invasive thoracolumbar spine surgery: a technical note</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author"><name><surname>Gatam</surname><given-names>Luthfi</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref><role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/><role content-type="https://credit.niso.org/contributor-roles/project-administration/"/><role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/><role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/></contrib>
<contrib contrib-type="author"><name><surname>Phedy</surname><given-names>Phedy</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref><role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/><role content-type="https://credit.niso.org/contributor-roles/project-administration/"/><role content-type="https://credit.niso.org/contributor-roles/resources/"/><role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/><role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/></contrib>
<contrib contrib-type="author"><name><surname>Husin</surname><given-names>Syafruddin</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref><role content-type="https://credit.niso.org/contributor-roles/resources/"/><role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/><role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/></contrib>
<contrib contrib-type="author"><name><surname>Mahadhipta</surname><given-names>Harmantya</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref><role content-type="https://credit.niso.org/contributor-roles/resources/"/><role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/><role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/></contrib>
<contrib contrib-type="author"><name><surname>Rizki Gatam</surname><given-names>Asrafi</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref><role content-type="https://credit.niso.org/contributor-roles/resources/"/><role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/><role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/></contrib>
<contrib contrib-type="author"><name><surname>Mitchel</surname><given-names>Mitchel</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/2841157/overview"/><role content-type="https://credit.niso.org/contributor-roles/data-curation/"/><role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/><role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/><role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/></contrib>
<contrib contrib-type="author"><name><surname>Gani</surname><given-names>Karina Sylvana</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/2841154/overview" /><role content-type="https://credit.niso.org/contributor-roles/data-curation/"/><role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/><role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/><role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/></contrib>
<contrib contrib-type="author" corresp="yes"><name><surname>Kholinne</surname><given-names>Erica</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff4"><sup>4</sup></xref>
<xref ref-type="corresp" rid="cor1">&#x002A;</xref><role content-type="https://credit.niso.org/contributor-roles/data-curation/"/><role content-type="https://credit.niso.org/contributor-roles/project-administration/"/><role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/><role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/></contrib>
</contrib-group>
<aff id="aff1"><label><sup>1</sup></label><institution>Department of Orthopedics, Gatam Institute</institution>, Tangerang, <country>Indonesia</country></aff>
<aff id="aff2"><label><sup>2</sup></label><institution>Department of Orthopedic Surgery, Fatmawati Hospital</institution>, Jakarta, <country>Indonesia</country></aff>
<aff id="aff3"><label><sup>3</sup></label><institution>Department of Orthopedic Surgery, Premier Bintaro Hospital</institution>, Tangerang, <country>Indonesia</country></aff>
<aff id="aff4"><label><sup>4</sup></label><institution>Department of Orthopedic Surgery, Faculty of Medicine, Universitas Trisakti</institution>, Jakarta, <country>Indonesia</country></aff>
<author-notes>
<fn fn-type="edited-by"><p><bold>Edited by:</bold> Ioannis Siasios, University Hospital of Alexandroupolis, Greece</p></fn>
<fn fn-type="edited-by"><p><bold>Reviewed by:</bold> Witantra Dhamar Hutami, RSUPN Dr. Cipto Mangunkusumo, Indonesia</p>
<p>Erwin Noor, Rumah Sakit Umum Pusat Fatmawati, Indonesia</p></fn>
<corresp id="cor1"><label>&#x002A;</label><bold>Correspondence:</bold> Erica Kholinne <email>kholinneerica@gmail.com</email></corresp>
</author-notes>
<pub-date pub-type="epub"><day>20</day><month>01</month><year>2025</year></pub-date>
<pub-date pub-type="collection"><year>2024</year></pub-date>
<volume>11</volume><elocation-id>1495251</elocation-id>
<history>
<date date-type="received"><day>12</day><month>09</month><year>2024</year></date>
<date date-type="accepted"><day>23</day><month>12</month><year>2024</year></date>
</history>
<permissions>
<copyright-statement>&#x00A9; 2025 Gatam, Phedy, Husin, Mahadhipta, Rizki Gatam, Mitchel, Gani and Kholinne.</copyright-statement>
<copyright-year>2025</copyright-year><copyright-holder>Gatam, Phedy, Husin, Mahadhipta, Rizki Gatam, Mitchel, Gani and Kholinne</copyright-holder><license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the <ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by/4.0/">Creative Commons Attribution License (CC BY)</ext-link>. The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license>
</permissions>
<abstract><sec><title>Background</title>
<p>Pedicle screw placement in spine surgery is a complex and delicate procedure that requires precise and accurate placement of pedicle screws. This technical note describes the steps involved in performing robotic assistance pedicle screw insertion in thoracolumbar spine surgery using the ExcelsiusGPS platform.</p>
</sec><sec><title>Methods</title>
<p>This paper outlines the surgical techniques and intraoperative workflow for pedicle screw placement using the ExcelsiusGPS system. It also covers the surgical process, including patient positioning, dynamic reference placement, intraoperative cone-beam tomography, screw planning, exposure, and insertion techniques for spinal stabilization.</p>
</sec><sec><title>Discussion</title>
<p>A meta-analysis highlighted the significant advantages of robotic spine surgery over traditional freehand techniques, including a notably lower complication rate (4.83&#x0025; vs. 14.97&#x0025;) and up to a tenfold reduction in surgeon radiation exposure compared to fluoroscopy. Additionally, robotic systems enhance pedicle screw placement accuracy, achieving a 91.7&#x0025; success rate. This higher accuracy is attributed to real-time screw planning, trajectory guidance, and precise adjustments in robotic-assisted surgery. These advantages establish robotic assistance as a crucial innovation for enhancing surgical precision and patient safety, although it requires careful handling of technical challenges like alignment changes in highly flexible bones and ensuring accurate instrument trajectory during screw placement.</p>
</sec><sec><title>Conclusion</title>
<p>Robotic-assisted spine surgery improves pedicle screw accuracy with real-time planning and trajectory adjustments, reducing complications and radiation exposure. However, higher costs and increased screw use warrant careful evaluation of its cost-effectiveness and impact on healthcare resources.</p>
</sec>
</abstract>
<kwd-group>
<kwd>thoracolumbar spine</kwd>
<kwd>pedicle screw placement</kwd>
<kwd>robotic spine surgery</kwd>
<kwd>ExcelsiusGPS robot</kwd>
<kwd>minimally invasive</kwd>
</kwd-group><counts>
<fig-count count="9"/>
<table-count count="1"/><equation-count count="0"/><ref-count count="26"/><page-count count="9"/><word-count count="0"/></counts><custom-meta-wrap><custom-meta><meta-name>section-at-acceptance</meta-name><meta-value>Neurosurgery</meta-value></custom-meta></custom-meta-wrap>
</article-meta>
</front>
<body><sec id="s1" sec-type="intro"><title>Introduction</title>
<p>Spine surgery is a complex and delicate medical procedure that sometimes requires precise and accurate pedicle screw placement to ensure successful outcomes. Pedicle screw malposition can lead to severe neurovascular injuries (<xref ref-type="bibr" rid="B1">1</xref>&#x2013;<xref ref-type="bibr" rid="B4">4</xref>). Efficient and accurate screw placement is fundamental in reducing iatrogenic complications and improving surgical outcomes. The limitations of human hands and visualization in achieving such precision can be challenging. Robotic assistance in spinal surgery minimizes these human errors. It ensures patient safety (<xref ref-type="bibr" rid="B5">5</xref>). Robot-assisted pedicle screw insertion has been introduced, to improve accuracy (<xref ref-type="bibr" rid="B6">6</xref>). Pedicle screw misplacement rates using conventional techniques range from 30&#x0025; in the lumbar spine to 55&#x0025; in the thoracic spine (<xref ref-type="bibr" rid="B7">7</xref>, <xref ref-type="bibr" rid="B8">8</xref>). In contrast, a study has demonstrated that robotic-assisted pedicle screw placement achieves success rates exceeding 90&#x0025; (<xref ref-type="bibr" rid="B9">9</xref>). A recent meta-analysis revealed that robotic-assisted techniques have a significantly lower complication rate compared to the freehand method (4.83&#x0025; vs. 14.97&#x0025;). However, the robotic-assisted group did not show a significant advantage in clinical efficacy (<xref ref-type="bibr" rid="B10">10</xref>). This technical note aims to describe the steps in performing robotic assistance pedicle screw placement in thoracolumbar spine surgery.</p>
</sec>
<sec id="s2"><title>Materials and equipments</title>
<sec id="s2a"><title>Robotic device and patient positioning</title>
<p>In this article, a robotic ExcelsiusGPS (Globus Medical; Audobon, PA, USA) for pedicle screw placement in thoracolumbar surgery was used (<xref ref-type="fig" rid="F1">Figure&#x00A0;1</xref>) (<xref ref-type="bibr" rid="B11">11</xref>). The patient is positioned prone on a Jackson table (<xref ref-type="fig" rid="F2">Figure&#x00A0;2</xref>). An area beneath the table is needed to place the image intensifier. Tools used in the procedure are shown in <xref ref-type="fig" rid="F3">Figure&#x00A0;3</xref>.</p>
<fig id="F1" position="float"><label>Figure 1</label>
<caption><p><bold>(A)</bold> ExclesiusGPS with a floor-fixable base and rigid robotic arm. <bold>(B)</bold> Navigation camera <bold>(C)</bold> Simulated operating theater using ExclesiusGPS (<xref ref-type="bibr" rid="B11">11</xref>).</p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fsurg-11-1495251-g001.tif"/>
</fig>
<fig id="F2" position="float"><label>Figure 2</label>
<caption><p>The patient is positioned on a Jackson table. A cushion and an armrest can be used under the patient to ensure proper positioning and comfort during the procedure.</p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fsurg-11-1495251-g002.tif"/>
</fig>
<fig id="F3" position="float"><label>Figure 3</label>
<caption><p>Tools used in the procedure. (1) Scalpel, (2A) Low profile quattro spike, bine clamp, and guide post, (2B) Surveillance marker, (3) Awl and array, (4) Drill and array, (5) High burr and array, (6) Tapper and array, (7) Dynamic Reference Base, (8) Intraoperative Cone-beam Tomography.</p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fsurg-11-1495251-g003.tif"/>
</fig>
</sec>
</sec>
<sec id="s3" sec-type="methods"><title>Methods</title>
<sec id="s3a"><title>Surgical planning/workflow</title>
<p>Several surgical workflows can be applied: preoperative, fluoroscopy, and intraoperative. This technical note will discuss only the intraoperative workflow. An intraoperative CT scan using O-arm (Medtronic Sofamor Danek, Inc., Memphis, TN) is performed (<xref ref-type="fig" rid="F4">Figure&#x00A0;4</xref>) to allow real-time imaging screw placement planning.</p>
<fig id="F4" position="float"><label>Figure 4</label>
<caption><p>Intraoperative CT scan using O-arm for intraoperative workflow.</p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fsurg-11-1495251-g004.tif"/>
</fig>
</sec>
<sec id="s3b"><title>Placement of dynamic reference base &#x0026; ICT</title>
<p>The DRB (dynamic reference base) was positioned with a low-profile quattro spike in the right posterior superior iliac spine (PSIS) with a stab incision and placed within 18&#x2005;cm of the surgical field. The surveillance marker (SM) was placed in the left PSIS (<xref ref-type="fig" rid="F5">Figure&#x00A0;5</xref>). The ICT (Intraoperative Cone-Beam Tomography) was attached to the spinous process and positioned near the desired screw level, parallel to the floor, and as close as possible to the skin without touching it. The DRB and ICT must remain visible to the navigation camera, even after inserting the O-arm. Proper positioning and stability of the DRB, ICT, and surveillance marker (SM), along with verifying anatomical landmarks before screw planning, are crucial for ensuring accuracy and effectiveness during surgery and achieving reliable surgical outcomes.</p>
<fig id="F5" position="float"><label>Figure 5</label>
<caption><p><bold>(A)</bold> The posterior superior iliac spine bilaterally is used for dynamic reference base and surveillance marker positioning. <bold>(B)</bold> ICT (Intraoperative Cone-Beam Tomography) was attached to the spinous process without touching the skin.</p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fsurg-11-1495251-g005.tif"/>
</fig>
</sec>
<sec id="s3c"><title>Screw planning</title>
<p>Effective screw planning using the O-arm and ExcelsiusGPS surgical system involves careful registration of navigated instruments and precise screw trajectory planning to avoid complications (<xref ref-type="fig" rid="F6">Figures&#x00A0;6</xref>, <xref ref-type="fig" rid="F7">7</xref>). For thoracic screws, it is crucial to prevent the transverse process slope, while lumbar screw planning must account for the superior articular process. Ensuring screw trajectory alignment without collisions and using 3D projections for accuracy are vital steps. In extremely obese patients, adjusting the end effector closer to the skin can help address the challenges posed by increased skin-to-bone distance, ensuring the robotic tools can reach the target effectively.</p>
<fig id="F6" position="float"><label>Figure 6</label>
<caption><p>Screw planning includes entry points, trajectories, screw length, and width.</p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fsurg-11-1495251-g006.tif"/>
</fig>
<fig id="F7" position="float"><label>Figure 7</label>
<caption><p>Intraoperative pedicle screw placement using the ExcelsiusGPS robotics system demonstrates the placement of a left-sided L4 pedicle screw.</p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fsurg-11-1495251-g007.tif"/>
</fig>
</sec>
<sec id="s3d"><title>Exposure</title>
<p>Once the end effector is in place, the surgeon will mark the skin incision using a scalpel inserted through the guide tube. The end effector is adjusted to accommodate a larger incision. During the incision, ensure that the fascia is adequately dissected beforehand. After the incision, the end effector is repositioned to its original position. The key to ensuring a good trajectory is achieving adequate exposure. Medial excision of the fascia is necessary to enable the proper trajectory for reaching the screw entry point.</p>
</sec>
<sec id="s3e"><title>Screw insertion and placement</title>
<p>The initial bur is positioned on the bone at the screw entry point to make an initial hole. The power burr is used before reaching the bone to prevent changes in bone alignment. Screws like Creo MIS screws or K-wire system are placed through the guide tube in the end effector. If using the K-wire system, insert the inner cannula into the guide tube after tapping. Once the K-wire is through the inner cannula, detach the cannula and reposition the end effector. Screws can be inserted with K-wire guidance. The screw is inserted until resistance from the tulip head against the bone is felt.</p>
</sec>
</sec>
<sec id="s4" sec-type="discussion"><title>Discussion</title>
<p>Robotic-assisted spine surgery is gaining popularity due to its multiple advantages. However, there are concerns regarding appropriate screw placement under various conditions. In highly flexible bones, alignment often changes with breathing. If this occurs, the anesthesiologist should hold the patient&#x0027;s breath in the expiratory phase, similar to during scanning. During this phase, the initial burr and high-speed drill can be performed. During tapping, the patient can resume normal breathing. After the tapping phase, screw placement follows. Furthermore, during screw placement, tactile feedback and deflection monitoring are crucial for making real-time adjustments and maintaining the instrument&#x0027;s trajectory. Deflection often occurs due to inadequate soft tissue or fascia release and the weight of the power drill. Using a hamburger grip can help counteract this weight (<xref ref-type="fig" rid="F8">Figure&#x00A0;8</xref>).</p>
<fig id="F8" position="float"><label>Figure 8</label>
<caption><p>The hamburger grip technique was used to facilitate screw insertion with a power drill system.</p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fsurg-11-1495251-g008.tif"/>
</fig>
<p>With the growing and widespread adoption of navigation technology, numerous studies have reported superior outcomes and lower complication rates compared to free-hand techniques. A meta-analysis reported fewer complication rates were found in robotic spine-assisted surgery, including less intraoperative blood loss, lower revision rate, fewer complications, and shorter length of hospital stay (<xref ref-type="bibr" rid="B12">12</xref>). An extensive meta-analysis of twenty RCTs reported a lower complication rate in the robot-assisted group than in free-hand techniques (4.83&#x0025; vs. 14.97&#x0025;) (<xref ref-type="fig" rid="F9">Figure&#x00A0;9</xref>) (<xref ref-type="bibr" rid="B10">10</xref>).</p>
<fig id="F9" position="float"><label>Figure 9</label>
<caption><p>The comparison of outcomes between robotic-assisted and conventional techniques in complication and accuracy (<xref ref-type="bibr" rid="B10">10</xref>, <xref ref-type="bibr" rid="B17">17</xref>).</p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fsurg-11-1495251-g009.tif"/>
</fig>
<p>Orthopedic surgeons are concerned about radiation exposure. Robotic systems reduce this exposure by avoiding the initial CT scan and minimizing intraoperative radiation. Research shows robotic procedures lower surgeon exposure significantly, with up to a tenfold decrease compared to fluoroscopy-guided techniques (<xref ref-type="bibr" rid="B13">13</xref>). Robotic-assisted surgery reduces radiation exposure by 54&#x0025;&#x2013;74&#x0025; compared to conventional CT scans (<xref ref-type="bibr" rid="B14">14</xref>).</p>
<p>The precision of pedicle screw placement is crucial, as misplaced screws can lead to devastating vascular, pulmonary, and neurologic complications and even dural leaks (<xref ref-type="bibr" rid="B15">15</xref>). A study found that in spine surgery with robot assistance, 91.7&#x0025; of pedicle screws were accurately placed, with only 6.8&#x0025; deviating by less than 2&#x2005;mm (<xref ref-type="bibr" rid="B16">16</xref>). Furthermore, most surgeons agree that a screw deviation of &#x2264;2&#x2005;mm is considered acceptable (<xref ref-type="bibr" rid="B15">15</xref>). Yue et al. showed that robot-assisted screw placement is more accurate than fluoroscopy-assisted placement, with a 93&#x0025; vs. 83&#x0025; accuracy rate and fewer superior facet joint devastations (<xref ref-type="fig" rid="F9">Figure&#x00A0;9</xref>) (<xref ref-type="bibr" rid="B17">17</xref>).</p>
<p>Robotic spine surgery conserves energy for deformity correction, thus enabling less stressful surgery. The utilization of robotic navigation in spine surgery offers a range of advantages and disadvantages (<xref ref-type="table" rid="T1">Table&#x00A0;1</xref>).</p>
<table-wrap id="T1" position="float"><label>Table 1</label>
<caption><p>Advantages and disadvantages of robotic spine surgery.</p></caption>
<table frame="hsides" rules="groups">
<colgroup>
<col align="left"/>
<col align="left"/>
</colgroup>
<thead>
<tr>
<th valign="top" align="left">Advantages</th>
<th valign="top" align="center">Disadvantages</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">&#x2022; Accurate trajectory &#x0026; size (<xref ref-type="bibr" rid="B18">18</xref>)</td>
<td valign="top" align="left">&#x2022; Learning curve (<xref ref-type="bibr" rid="B15">15</xref>, <xref ref-type="bibr" rid="B19">19</xref>)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2022; Better implant purchasing (<xref ref-type="bibr" rid="B10">10</xref>, <xref ref-type="bibr" rid="B12">12</xref>)</td>
<td valign="top" align="left">&#x2022; Slightly longer duration (<xref ref-type="bibr" rid="B20">20</xref>)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2022; Safety (<xref ref-type="bibr" rid="B21">21</xref>)</td>
<td valign="top" align="left">&#x2022; Increased cost (<xref ref-type="bibr" rid="B22">22</xref>, <xref ref-type="bibr" rid="B23">23</xref>)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2022; Minimize complication (<xref ref-type="bibr" rid="B24">24</xref>)</td>
<td valign="top" align="left">&#x2022; Tent to put more screws (<xref ref-type="bibr" rid="B23">23</xref>)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2022; Early recovery (<xref ref-type="bibr" rid="B24">24</xref>, <xref ref-type="bibr" rid="B25">25</xref>)</td>
<td valign="top" align="left"/>
</tr>
<tr>
<td valign="top" align="left">&#x2022; Lower radiation for the surgeon and the patient (<xref ref-type="bibr" rid="B4">4</xref>, <xref ref-type="bibr" rid="B14">14</xref>, <xref ref-type="bibr" rid="B25">25</xref>)</td>
<td valign="top" align="left"/>
</tr>
<tr>
<td valign="top" align="left">&#x2022; Less stressful (<xref ref-type="bibr" rid="B10">10</xref>)</td>
<td valign="top" align="left"/>
</tr>
<tr>
<td valign="top" align="left">&#x2022; Conserve energy for deformity correction (<xref ref-type="bibr" rid="B24">24</xref>)</td>
<td valign="top" align="left"/>
</tr>
<tr>
<td valign="top" align="left">&#x2022; lower surgeon burn-out (<xref ref-type="bibr" rid="B10">10</xref>)</td>
<td valign="top" align="left"/>
</tr>
<tr>
<td valign="top" align="left">&#x2022; Minimally invasive (<xref ref-type="bibr" rid="B26">26</xref>)</td>
<td valign="top" align="left"/>
</tr>
</tbody>
</table>
</table-wrap>
<sec id="s4a"><title>Future directions</title>
<p>The integration of robotic systems in spine surgery is progressing rapidly, with advancements aimed at enhancing efficiency and surgical workflow through improved imaging software and automation. The scope of robotic systems is expected to broaden to include cervical and pelvic fixation and more complex spinal procedures.</p>
</sec>
</sec>
<sec id="s5" sec-type="conclusions"><title>Conclusion</title>
<p>Robotic-assisted spine surgery has improved the accuracy of pedicle screw insertion by providing real-time planning, precise trajectory guidance, and intraoperative adjustments. This enhanced precision reduces complications, including misplacement, while also minimizing radiation exposure to the surgeon and the patient. However, these benefits come with increased costs and a higher usage of screws, necessitating careful evaluation of the procedure&#x0027;s cost-effectiveness and its overall impact on patient outcomes and healthcare resources.</p>
</sec>
</body>
<back>
<sec id="s6" sec-type="data-availability"><title>Data availability statement</title>
<p>The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.</p>
</sec>
<sec id="s7" sec-type="ethics-statement"><title>Ethics statement</title>
<p>Written informed consent was obtained from the patient for publication and any accompanying images.</p>
</sec>
<sec id="s8" sec-type="author-contributions"><title>Author contributions</title>
<p>LG: Conceptualization, Project administration, Writing &#x2013; original draft, Writing &#x2013; review &#x0026; editing. PP: Conceptualization, Project administration, Resources, Writing &#x2013; original draft, Writing &#x2013; review &#x0026; editing. SH: Resources, Writing &#x2013; original draft, Writing &#x2013; review &#x0026; editing. HM: Resources, Writing &#x2013; original draft, Writing &#x2013; review &#x0026; editing. AR: Resources, Writing &#x2013; original draft, Writing &#x2013; review &#x0026; editing. MM: Data curation, Formal Analysis, Writing &#x2013; original draft, Writing &#x2013; review &#x0026; editing. KG: Data curation, Formal Analysis, Writing &#x2013; original draft, Writing &#x2013; review &#x0026; editing. EK: Data curation, Project administration, Writing &#x2013; original draft, Writing &#x2013; review &#x0026; editing.</p>
</sec>
<sec id="s9" sec-type="funding-information"><title>Funding</title>
<p>The author(s) declare that no financial support was received for the research, authorship, and/or publication of this article.</p>
</sec>
<ack><title>Acknowledgments</title>
<p>We thank Maharani Asmara Putri from Mapson Arya Parahita and William Kingston Xie for the technical support.</p>
</ack>
<sec id="s10" sec-type="COI-statement"><title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec id="s11" sec-type="disclaimer"><title>Publisher&#x0027;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ref-list><title>References</title>
<ref id="B1"><label>1.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gelalis</surname><given-names>ID</given-names></name><name><surname>Paschos</surname><given-names>NK</given-names></name><name><surname>Pakos</surname><given-names>EE</given-names></name><name><surname>Politis</surname><given-names>AN</given-names></name><name><surname>Arnaoutoglou</surname><given-names>CM</given-names></name><name><surname>Karageorgos</surname><given-names>AC</given-names></name><etal/></person-group> <article-title>Accuracy of pedicle screw placement: a systematic review of prospective <italic>in vivo</italic> studies comparing free hand, fluoroscopy guidance and navigation techniques</article-title>. <source>Eur Spine J</source>. (<year>2012</year>) <volume>21</volume>(<issue>2</issue>):<fpage>247</fpage>&#x2013;<lpage>55</lpage>. <pub-id pub-id-type="doi">10.1007/s00586-011-2011-3</pub-id><pub-id pub-id-type="pmid">21901328</pub-id></citation></ref>
<ref id="B2"><label>2.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhang</surname><given-names>Q</given-names></name><name><surname>Han</surname><given-names>XG</given-names></name><name><surname>Xu</surname><given-names>YF</given-names></name><name><surname>Fan</surname><given-names>MX</given-names></name><name><surname>Zhao</surname><given-names>JW</given-names></name><name><surname>Liu</surname><given-names>YJ</given-names></name><etal/></person-group> <article-title>Robotic navigation during spine surgery</article-title>. <source>Expert Rev Med Devices</source>. (<year>2020</year>) <volume>17</volume>(<issue>1</issue>):<fpage>27</fpage>&#x2013;<lpage>32</lpage>. <pub-id pub-id-type="doi">10.1080/17434440.2020.1699405</pub-id><pub-id pub-id-type="pmid">31778610</pub-id></citation></ref>
<ref id="B3"><label>3.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Huang</surname><given-names>M</given-names></name><name><surname>Tetreault</surname><given-names>TA</given-names></name><name><surname>Vaishnav</surname><given-names>A</given-names></name><name><surname>York</surname><given-names>PJ</given-names></name><name><surname>Staub</surname><given-names>BN</given-names></name></person-group>. <article-title>The current state of navigation in robotic spine surgery</article-title>. <source>Ann Transl Med</source>. (<year>2021</year>) <volume>9</volume>(<issue>1</issue>):<fpage>86</fpage>. <pub-id pub-id-type="doi">10.21037/atm-2020-ioi-07</pub-id><pub-id pub-id-type="pmid">33553379</pub-id></citation></ref>
<ref id="B4"><label>4.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Farber</surname><given-names>SH</given-names></name><name><surname>Pacult</surname><given-names>MA</given-names></name><name><surname>Godzik</surname><given-names>J</given-names></name><name><surname>Walker</surname><given-names>CT</given-names></name><name><surname>Turner</surname><given-names>JD</given-names></name><name><surname>Porter</surname><given-names>RW</given-names></name><etal/></person-group> <article-title>Robotics in spine surgery: a technical overview and review of key concepts</article-title>. <source>Front Surg</source>. (<year>2021</year>) <volume>8</volume>:8578674. <pub-id pub-id-type="doi">10.3389/fsurg.2021.578674</pub-id><pub-id pub-id-type="pmid">33708791</pub-id></citation></ref>
<ref id="B5"><label>5.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kalidindi</surname><given-names>KKV</given-names></name><name><surname>Sharma</surname><given-names>JK</given-names></name><name><surname>Jagadeesh</surname><given-names>NH</given-names></name><name><surname>Sath</surname><given-names>S</given-names></name><name><surname>Chhabra</surname><given-names>HS</given-names></name></person-group>. <article-title>Robotic spine surgery: a review of the present status</article-title>. <source>J Med Eng Technol</source>. (<year>2020</year>) <volume>44</volume>(<issue>7</issue>):<fpage>431</fpage>&#x2013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1080/03091902.2020.1799098</pub-id><pub-id pub-id-type="pmid">32886014</pub-id></citation></ref>
<ref id="B6"><label>6.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Togawa</surname><given-names>D</given-names></name><name><surname>Kayanja</surname><given-names>MM</given-names></name><name><surname>Reinhardt</surname><given-names>MK</given-names></name><name><surname>Shoham</surname><given-names>M</given-names></name><name><surname>Balter</surname><given-names>A</given-names></name><name><surname>Friedlander</surname><given-names>A</given-names></name><etal/></person-group> <article-title>Bone-mounted miniature robotic guidance for pedicle screw and translaminar facet screw placement: part 2&#x2013;evaluation of system accuracy</article-title>. <source>Neurosurgery</source>. (<year>2007</year>) <volume>60</volume>(<issue>2</issue>):<fpage>129</fpage>&#x2013;<lpage>39</lpage>. <pub-id pub-id-type="doi">10.1227/01.NEU.0000249257.16912.AA</pub-id>.</citation></ref>
<ref id="B7"><label>7.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gertzbein</surname><given-names>S</given-names></name><name><surname>Robbins</surname><given-names>S</given-names></name></person-group>. <article-title>Accuracy of pedicular screw placement <italic>in vivo</italic></article-title>. <source>Spine (Phila Pa 1976)</source>. (<year>1990</year>) <volume>15</volume>(<issue>1</issue>):<fpage>11</fpage>&#x2013;<lpage>4</lpage>. <pub-id pub-id-type="doi">10.1097/00007632-199001000-00004</pub-id><pub-id pub-id-type="pmid">2326693</pub-id></citation></ref>
<ref id="B8"><label>8.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Weinstein</surname><given-names>JN</given-names></name><name><surname>Spratt</surname><given-names>KF</given-names></name><name><surname>Spengler</surname><given-names>D</given-names></name><name><surname>Brick</surname><given-names>C</given-names></name><name><surname>Reid</surname><given-names>S</given-names></name></person-group>. <article-title>Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement</article-title>. <source>Spine (Phila Pa 1976)</source>. (<year>1988</year>) <volume>13</volume>(<issue>9</issue>):<fpage>1012</fpage>&#x2013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1097/00007632-198809000-00008</pub-id><pub-id pub-id-type="pmid">3206294</pub-id></citation></ref>
<ref id="B9"><label>9.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gao</surname><given-names>S</given-names></name><name><surname>Wei</surname><given-names>J</given-names></name><name><surname>Li</surname><given-names>W</given-names></name><name><surname>Zhang</surname><given-names>L</given-names></name><name><surname>Cao</surname><given-names>C</given-names></name><name><surname>Zhai</surname><given-names>J</given-names></name><etal/></person-group> <article-title>Accuracy of robot-assisted percutaneous pedicle screw placement under regional anesthesia: a retrospective cohort study</article-title>. <source>Pain Res Manag</source>. (<year>2021</year>) <volume>2021</volume>(<issue>3</issue>):<fpage>178</fpage>&#x2013;<lpage>80</lpage>. <pub-id pub-id-type="doi">10.1155/2021/6894001</pub-id></citation></ref>
<ref id="B10"><label>10.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sun</surname><given-names>WX</given-names></name><name><surname>Huang</surname><given-names>WQ</given-names></name><name><surname>Li</surname><given-names>HY</given-names></name><name><surname>Wang</surname><given-names>HS</given-names></name><name><surname>Guo</surname><given-names>SL</given-names></name><name><surname>Dong</surname><given-names>J</given-names></name><etal/></person-group> <article-title>Clinical efficacy of robotic spine surgery: an updated systematic review of 20 randomized controlled trials</article-title>. <source>EFORT open Rev</source>. (<year>2023</year>) <volume>8</volume>(<issue>11</issue>):<fpage>841</fpage>&#x2013;<lpage>53</lpage>. <pub-id pub-id-type="doi">10.1530/EOR-23-0125</pub-id><pub-id pub-id-type="pmid">37909700</pub-id></citation></ref>
<ref id="B11"><label>11.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Vaccaro</surname><given-names>AR</given-names></name><name><surname>Harris</surname><given-names>JA</given-names></name><name><surname>Hussain</surname><given-names>MM</given-names></name><name><surname>Wadhwa</surname><given-names>R</given-names></name><name><surname>Chang</surname><given-names>VW</given-names></name><name><surname>Schroerlucke</surname><given-names>SR</given-names></name><etal/></person-group> <article-title>Assessment of surgical procedural time. Pedicle screw accuracy, and clinician radiation exposure of a novel robotic navigation system compared with conventional open and percutaneous freehand techniques: a Cadaveric investigation</article-title>. <source>Glob Spine J</source>. (<year>2020</year>) <volume>10</volume>(<issue>7</issue>):<fpage>814</fpage>&#x2013;<lpage>25</lpage>. <pub-id pub-id-type="doi">10.1177/2192568219879083</pub-id></citation></ref>
<ref id="B12"><label>12.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ahmed</surname><given-names>AK</given-names></name><name><surname>Zygourakis</surname><given-names>CC</given-names></name><name><surname>Kalb</surname><given-names>S</given-names></name><name><surname>Zhu</surname><given-names>AM</given-names></name><name><surname>Molina</surname><given-names>CA</given-names></name><name><surname>Jiang</surname><given-names>B</given-names></name><etal/></person-group> <article-title>First spine surgery utilizing real-time image-guided robotic assistance</article-title>. <source>Comput Assist Surg</source>. (<year>2019</year>) <volume>24</volume>(<issue>1</issue>):<fpage>13</fpage>&#x2013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1080/24699322.2018.1542029</pub-id></citation></ref>
<ref id="B13"><label>13.</label><citation citation-type="other"><article-title>ExcelsiusGPS&#x00AE; interbody solutions</article-title> (<year>2023</year>). <comment>Available online at:</comment> <ext-link ext-link-type="uri" xlink:href="https://www.globusmedical.com/musculoskeletal-solutions/excelsiustechnology/excelsiusgps/excelsiusgps-interbody-solutions/">https://www.globusmedical.com/musculoskeletal-solutions/excelsiustechnology/excelsiusgps/excelsiusgps-interbody-solutions/</ext-link> (Accessed May 10, 2024).</citation></ref>
<ref id="B14"><label>14.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Villard</surname><given-names>J</given-names></name><name><surname>Ryang</surname><given-names>YM</given-names></name><name><surname>Demetriades</surname><given-names>AK</given-names></name><name><surname>Reinke</surname><given-names>A</given-names></name><name><surname>Behr</surname><given-names>M</given-names></name><name><surname>Preuss</surname><given-names>A</given-names></name><etal/></person-group> <article-title>Radiation exposure to the surgeon and the patient during posterior lumbar spinal instrumentation: a prospective randomized comparison of navigated versus non-navigated freehand techniques</article-title>. <source>Spine (Phila Pa 1976)</source>. (<year>2014</year>) <volume>39</volume>(<issue>13</issue>):<fpage>1004</fpage>&#x2013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1097/BRS.0000000000000351</pub-id><pub-id pub-id-type="pmid">24732833</pub-id></citation></ref>
<ref id="B15"><label>15.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Schatlo</surname><given-names>B</given-names></name><name><surname>Martinez</surname><given-names>R</given-names></name><name><surname>Alaid</surname><given-names>A</given-names></name><name><surname>von Eckardstein</surname><given-names>K</given-names></name><name><surname>Akhavan-Sigari</surname><given-names>R</given-names></name><name><surname>Hahn</surname><given-names>A</given-names></name><etal/></person-group> <article-title>Unskilled unawareness and the learning curve in robotic spine surgery</article-title>. <source>Acta Neurochir (Wien)</source>. (<year>2015</year>) <volume>157</volume>(<issue>10</issue>):<fpage>1819</fpage>&#x2013;<lpage>23</lpage>. <pub-id pub-id-type="doi">10.1007/s00701-015-2535-0</pub-id><pub-id pub-id-type="pmid">26287268</pub-id></citation></ref>
<ref id="B16"><label>16.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Keric</surname><given-names>N</given-names></name><name><surname>Doenitz</surname><given-names>C</given-names></name><name><surname>Haj</surname><given-names>A</given-names></name><name><surname>Rachwal-Czyzewicz</surname><given-names>I</given-names></name><name><surname>Renovanz</surname><given-names>M</given-names></name><name><surname>Wesp</surname><given-names>DMA</given-names></name><etal/></person-group> <article-title>Evaluation of robot-guided minimally invasive implantation of 2067 pedicle screws</article-title>. <source>Neurosurg Focus</source>. (<year>2017</year>) <volume>42</volume>(<issue>5</issue>):<fpage>30</fpage>&#x2013;<lpage>4</lpage>. <pub-id pub-id-type="doi">10.3171/2017.2.FOCUS16552</pub-id></citation></ref>
<ref id="B17"><label>17.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kosmopoulos</surname><given-names>V</given-names></name><name><surname>Theumann</surname><given-names>N</given-names></name><name><surname>Binaghi</surname><given-names>S</given-names></name><name><surname>Schizas</surname><given-names>C</given-names></name></person-group>. <article-title>Observer reliability in evaluating pedicle screw placement using computed tomography</article-title>. <source>Int Orthop</source>. (<year>2007</year>) <volume>31</volume>(<issue>4</issue>):<fpage>531</fpage>&#x2013;<lpage>6</lpage>. <pub-id pub-id-type="doi">10.1007/s00264-006-0230-8</pub-id><pub-id pub-id-type="pmid">16967277</pub-id></citation></ref>
<ref id="B18"><label>18.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pechlivanis</surname><given-names>I</given-names></name><name><surname>Kiriyanthan</surname><given-names>G</given-names></name><name><surname>Engelhardt</surname><given-names>M</given-names></name><name><surname>Scholz</surname><given-names>M</given-names></name><name><surname>L&#x00FC;cke</surname><given-names>S</given-names></name><name><surname>Harders</surname><given-names>A</given-names></name><etal/></person-group> <article-title>Percutaneous placement of pedicle screws in the lumbar spine using a bone mounted miniature robotic system: first experiences and accuracy of screw placement</article-title>. <source>Spine (Phila Pa 1976)</source>. (<year>2009</year>) <volume>34</volume>(<issue>4</issue>):<fpage>392</fpage>&#x2013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1097/BRS.0b013e318191ed32</pub-id><pub-id pub-id-type="pmid">19214099</pub-id></citation></ref>
<ref id="B19"><label>19.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hu</surname><given-names>X</given-names></name><name><surname>Lieberman</surname><given-names>IH</given-names></name></person-group>. <article-title>What is the learning curve for robotic-assisted pedicle screw placement in spine surgery?</article-title> <source>Clin Orthop Relat Res</source>. (<year>2014</year>) <volume>472</volume>(<issue>6</issue>):<fpage>1839</fpage>&#x2013;<lpage>44</lpage>. <pub-id pub-id-type="doi">10.1007/s11999-013-3291-1</pub-id><pub-id pub-id-type="pmid">24048889</pub-id></citation></ref>
<ref id="B20"><label>20.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ringel</surname><given-names>F</given-names></name><name><surname>St&#x00FC;er</surname><given-names>C</given-names></name><name><surname>Reinke</surname><given-names>A</given-names></name><name><surname>Preuss</surname><given-names>A</given-names></name><name><surname>Behr</surname><given-names>M</given-names></name><name><surname>Auer</surname><given-names>F</given-names></name><etal/></person-group> <article-title>Accuracy of robot-assisted placement of lumbar and sacral pedicle screws: a prospective randomized comparison to conventional freehand screw implantation</article-title>. <source>Spine (Phila Pa 1976)</source>. (<year>2012</year>) <volume>37</volume>(<issue>8</issue>):<fpage>E496</fpage>&#x2013;<lpage>501</lpage>. <pub-id pub-id-type="doi">10.1097/BRS.0b013e31824b7767</pub-id><pub-id pub-id-type="pmid">22310097</pub-id></citation></ref>
<ref id="B21"><label>21.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Devito</surname><given-names>DP</given-names></name><name><surname>Kaplan</surname><given-names>L</given-names></name><name><surname>Dietl</surname><given-names>R</given-names></name><name><surname>Pfeiffer</surname><given-names>M</given-names></name><name><surname>Horne</surname><given-names>D</given-names></name><name><surname>Silberstein</surname><given-names>B</given-names></name><etal/></person-group> <article-title>Clinical acceptance and accuracy assessment of spinal implants guided with SpineAssist surgical robot: retrospective study</article-title>. <source>Spine (Phila Pa 1976)</source>. (<year>2010</year>) <volume>35</volume>(<issue>24</issue>):<fpage>2109</fpage>&#x2013;<lpage>15</lpage>. <pub-id pub-id-type="doi">10.1097/BRS.0b013e3181d323ab</pub-id><pub-id pub-id-type="pmid">21079498</pub-id></citation></ref>
<ref id="B22"><label>22.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Overley</surname><given-names>SC</given-names></name><name><surname>Cho</surname><given-names>SK</given-names></name><name><surname>Mehta</surname><given-names>AI</given-names></name><name><surname>Arnold</surname><given-names>PM</given-names></name></person-group>. <article-title>Navigation and robotics in spinal surgery: where are we now?</article-title> <source>Neurosurgery</source>. (<year>2017</year>) <volume>80</volume>(<issue>3S</issue>):<fpage>S86</fpage>&#x2013;<lpage>99</lpage>. <pub-id pub-id-type="doi">10.1093/neuros/nyw077</pub-id><pub-id pub-id-type="pmid">28350944</pub-id></citation></ref>
<ref id="B23"><label>23.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lee</surname><given-names>YS</given-names></name><name><surname>Cho</surname><given-names>DC</given-names></name><name><surname>Kim</surname><given-names>KT</given-names></name></person-group>. <article-title>Navigation-guided/robot-assisted spinal surgery: a review article</article-title>. <source>Neurospine</source>. (<year>2024</year>) <volume>21</volume>(<issue>1</issue>):<fpage>8</fpage>&#x2013;<lpage>17</lpage>. <pub-id pub-id-type="doi">10.14245/ns.2347184.592</pub-id><pub-id pub-id-type="pmid">38569627</pub-id></citation></ref>
<ref id="B24"><label>24.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Li</surname><given-names>J</given-names></name><name><surname>Fang</surname><given-names>Y</given-names></name><name><surname>Jin</surname><given-names>Z</given-names></name><name><surname>Wang</surname><given-names>Y</given-names></name><name><surname>Yu</surname><given-names>M</given-names></name></person-group>. <article-title>The impact of robot-assisted spine surgeries on clinical outcomes: a systemic review and meta-analysis</article-title>. <source>Int J Med Robot</source>. (<year>2020</year>) <volume>16</volume>(<issue>6</issue>):<fpage>1</fpage>&#x2013;<lpage>14</lpage>. <pub-id pub-id-type="doi">10.1002/rcs.2143</pub-id></citation></ref>
<ref id="B25"><label>25.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hyun</surname><given-names>SJ</given-names></name><name><surname>Kim</surname><given-names>KJ</given-names></name><name><surname>Jahng</surname><given-names>TA</given-names></name><name><surname>Kim</surname><given-names>HJ</given-names></name></person-group>. <article-title>Minimally invasive robotic versus open fluoroscopic-guided spinal instrumented fusions: a randomized controlled trial</article-title>. <source>Spine (Phila Pa 1976)</source>. (<year>2017</year>) <volume>42</volume>(<issue>6</issue>):<fpage>353</fpage>&#x2013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1097/BRS.0000000000001778</pub-id><pub-id pub-id-type="pmid">27398897</pub-id></citation></ref>
<ref id="B26"><label>26.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fu</surname><given-names>W</given-names></name><name><surname>Tong</surname><given-names>J</given-names></name><name><surname>Liu</surname><given-names>G</given-names></name><name><surname>Zheng</surname><given-names>Y</given-names></name><name><surname>Wang</surname><given-names>S</given-names></name><name><surname>Abdelrahim</surname><given-names>MEA</given-names></name><etal/></person-group> <article-title>Robot-assisted technique vs conventional freehand technique in spine surgery: a meta-analysis</article-title>. <source>Int J Clin Pract</source>. (<year>2021</year>) <volume>75</volume>(<issue>5</issue>). <pub-id pub-id-type="doi">10.1111/ijcp.13964</pub-id></citation></ref></ref-list>
</back>
</article>