<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="brief-report" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xml:lang="EN">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Reprod. Health</journal-id>
<journal-title>Frontiers in Reproductive Health</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Reprod. Health</abbrev-journal-title>
<issn pub-type="epub">2673-3153</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/frph.2023.1224421</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Reproductive Health</subject>
<subj-group>
<subject>Perspective</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Menstrual tampons and vaginal pessaries: regulation of intravaginal medical devices by the US FDA</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes"><name><surname>Pollard</surname><given-names>Colin M.</given-names></name>
<xref ref-type="corresp" rid="cor1">&#x002A;</xref><uri xlink:href="https://loop.frontiersin.org/people/2057021/overview"/></contrib>
</contrib-group>
<aff><institution>Consultant</institution>, <addr-line>Washington, DC</addr-line>, <country>United States</country></aff>
<author-notes>
<fn fn-type="edited-by"><p><bold>Edited by:</bold> Ken Miller, Margoshes Miller Consulting, LLC, United States</p></fn>
<fn fn-type="edited-by"><p><bold>Reviewed by:</bold> Mark Anderson, Independent Researcher, Cincinnati, United States Kathleen Blieszner, Independent Researcher, Cincinnati, United States</p></fn>
<corresp id="cor1"><label>&#x002A;</label><bold>Correspondence:</bold> Colin M. Pollard <email>colin_pollard@comcast.net</email></corresp>
</author-notes>
<pub-date pub-type="epub"><day>19</day><month>09</month><year>2023</year></pub-date>
<pub-date pub-type="collection"><year>2023</year></pub-date>
<volume>5</volume><elocation-id>1224421</elocation-id>
<history>
<date date-type="received"><day>17</day><month>05</month><year>2023</year></date>
<date date-type="accepted"><day>02</day><month>08</month><year>2023</year></date>
</history>
<permissions>
<copyright-statement>&#x00A9; 2023 Pollard.</copyright-statement>
<copyright-year>2023</copyright-year><copyright-holder>Pollard</copyright-holder><license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the <ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by/4.0/">Creative Commons Attribution License (CC BY)</ext-link>. The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license>
</permissions>
<abstract>
<p>Catamenial products like menstrual tampons for managing menses and vaginal pessaries for managing urinary incontinence and uterine prolapse are products that can be inserted and removed from the vagina repeatedly over a woman&#x0027;s lifetime. In the United States (US), these products are considered to be medical devices and are regulated by the Center for Devices &#x0026; Radiological Health (CDRH) of the Food and Drug Administration (FDA). As such, they are subject to both premarket and postmarket regulatory controls. Both tampons and pessaries have a long history of safe and effective use, and FDA applies a risk-based approach to both premarket entry as well as continued postmarket regulatory controls. Practicing clinicians are often the initial source of ideas for medical device improvements. This article is intended to help such clinicians to understand the regulatory challenges faced by development teams who seek to introduce these kinds of products to the US market. It explains FDA&#x0027;s risk-based classification of medical devices and the 510(k) premarket notification as the primary regulatory mechanism for market entry. It also highlights key FDA guidance documents and encourages early engagement with FDA when appropriate.</p>
</abstract>
<kwd-group>
<kwd>menstrual tampons</kwd>
<kwd>vaginal pessaries</kwd>
<kwd>medical device</kwd>
<kwd>regulation</kwd>
<kwd>food and drug administration</kwd>
<kwd>510(k) premarket notification</kwd>
</kwd-group>
<counts>
<fig-count count="0"/>
<table-count count="2"/><equation-count count="0"/><ref-count count="20"/><page-count count="0"/><word-count count="0"/></counts><custom-meta-wrap><custom-meta><meta-name>section-at-acceptance</meta-name><meta-value>Gynecology</meta-value></custom-meta></custom-meta-wrap>
</article-meta>
</front>
<body>
<p>Menstrual tampons and vaginal pessaries are medical devices that are inserted into the vagina to achieve their effect. Women have used menstrual tampons for decades to manage menstrual bleeding. Likewise, women have used vaginal pessaries for decades as a nonsurgical option for the management of urinary incontinence and pelvic organ prolapse. These devices can be inserted intravaginally and removed, repeatedly, for years. In general, FDA considers both tampons and pessaries to be safe and effective medical devices. Under a statutory risk-based classification scheme, these products are regulated by the Center for Devices and Radiological Health (CDRH), part of the Food and Drug Administration (FDA), to ensure their continued safety and effectiveness. This article provides an overview of how FDA regulates these products. For the purposes of this discussion, this article will use the terms &#x201C;medical device&#x201D;, &#x201C;device&#x201D; and &#x201C;product&#x201D; interchangeably. The article also uses the two terms, &#x201C;manufacturer&#x201D; and &#x201C;developer&#x201D;, interchangeably.</p>
<sec id="s1"><title>Medical device classification and its regulatory implications</title>
<p>The statutory foundation of medical device regulation is a 3-tiered risk-based classification system. Every medical device is classified according to its specific risks to health, from low to high, and each classification level establishes a set of controls from which FDA chooses to best regulate the individual product. See <xref ref-type="table" rid="T1">Table&#x00A0;1</xref>.
<list list-type="simple">
<list-item><label>&#x25A1;</label><p>Class I: General Controls</p></list-item>
<list-item><label>&#x25A1;</label><p>Class II: Special Controls</p></list-item>
<list-item><label>&#x25A1;</label><p>Class III: Premarket Approval</p></list-item>
</list><xref ref-type="table" rid="T2">Table&#x00A0;2</xref> shows the classification of menstrual pads and tampons, menstrual cups and vaginal pessaries. Developers of medical devices are strongly encouraged to explore the CDRH/FDA website (<xref ref-type="bibr" rid="B3">3</xref>) and learn more about device classification and the regulatory controls that derive from each class. This website is a good place to start.</p>
<table-wrap id="T1" position="float"><label>Table 1</label>
<caption><p>below summarizes the regulatory controls provided by each classification level.</p></caption>
<table frame="hsides" rules="groups">
<colgroup>
<col align="left"/>
<col align="left"/>
</colgroup>
<thead>
<tr>
<th colspan="2">Medical device classification (<xref ref-type="bibr" rid="B1">1</xref>)</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Class I: general controls<break/>with and without exemptions</td>
<td valign="top" align="left"><italic>General Controls are a set of regulatory requirements that generally apply to all medical devices. For some medical devices, these are sufficient to ensure their safety and effectiveness. Discussed further below, these general controls include establishment registration and listing, labeling, medical device reporting, 510(k) premarket notification, the investigational device exemption (IDE) regulations that apply to clinical trials, good manufacturing practices (GMPs) as set forth in the Quality Systems regulation, general labeling requirements and medical device reporting (MDR) in the postmarket setting.</italic> <italic>FDA has exempted most Class I devices from the requirement for 510(k) premarket notification.</italic></td>
</tr>
<tr>
<td valign="top" align="left">Class II: special controls<break/>also includes general controls</td>
<td valign="top" align="left"><italic>When FDA determines that Class I general controls are insufficient to ensure the safety and effectiveness of a type of medical device, the agency assigns that device to Class II. Special Controls are typically device-specific and may include performance standards, postmarket surveillance and/or patient registries, special premarket data requirements, specific labeling requirements, and adherence to designated FDA guidelines.</italic></td>
</tr>
<tr>
<td valign="top" align="left">Class III: premarket approval</td>
<td valign="top" align="left"><italic>If FDA determines that Class I and Class II regulatory controls are insufficient to ensure the safety and effectiveness, the agency assigns that device to the highest risk category: Class III Premarket Approval (PMA). The PMA application is a rigorous premarket FDA review process.</italic> <italic>The intravaginal products subject of this issue are not Class III devices, so this article will not spend time on Class III requirements.</italic></td>
</tr>
</tbody>
</table>
</table-wrap>
<table-wrap id="T2" position="float"><label>Table 2</label>
<caption><p>Classification of intravaginal devices.</p></caption>
<table frame="hsides" rules="groups">
<colgroup>
<col align="left"/>
<col align="center"/>
</colgroup>
<tbody>
<tr>
<td valign="top" align="left" colspan="2">The classification of each medical device can be found in the Code of Federal Regulations (CFR), Title 2 (<xref ref-type="bibr" rid="B2">2</xref>) 1. Listed below are the classification designations of several intravaginal devices.</td>
</tr>
<tr>
<td valign="top">Menstrual pad</td>
<td valign="top">Class I: (21 CFR 884.5425 and 884.5435)</td>
</tr>
<tr>
<td valign="top">Menstrual tampon</td>
<td valign="top">Class II: (21 CFR 884.5460 and 884.5470)</td>
</tr>
<tr>
<td valign="top">Menstrual cup</td>
<td valign="top">Class II: (21 CFR 884.5400)</td>
</tr>
<tr>
<td valign="top">Vaginal pessary</td>
<td valign="top">Class II: (21 CFR 884.3575)</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="FN002"><p>With a few narrowly defined exceptions, Class I menstrual pads are exempt from the requirement of 510(k) premarket notification. Class II menstrual cups are also exempt from the 510(k) requirement.</p></fn>
</table-wrap-foot>
</table-wrap>
<p>This article will explore how this basic regulatory structure applies to menstrual tampons and vaginal pessaries.</p>
</sec>
<sec id="s2"><title>The 510(k) premarket notification and bringing a menstrual tampon to market</title>
<p>To bring its new product to market, the manufacturer (or developer) of a Class II medical device must submit a <italic>510(k) premarket notification</italic> to the FDA. The essence of such a notification is the identification of a legally-marketed device for comparison, known as a <italic>predicate device</italic>, and a showing that the new device is <italic>substantially equivalent</italic> to the predicate device in terms of safety and effectiveness, with an emphasis on device design and intended use. In making the 510(k) submission, the manufacturer follows the prescribed regulations and FDA guidance, more on that later. If the manufacturer&#x0027;s arguments for substantial equivalence prevail and FDA determines that the new product (in this case a menstrual tampon) is substantially equivalent to the predicate device, then the manufacturer (or product developer) may bring the product to market. However, if FDA finds that the new device design raises new types of questions on safety or effectiveness, or if FDA finds that the indication for use represents a new intended use, then FDA will issue a finding of NOT (emphasis added) substantially equivalent. By statute, a determination of <italic>not substantially equivalent</italic> places the new device into Class III, and a Premarket Approval Application is required. For a tampon, this latter possibility is highly unlikely.</p>
<p>To help the developer of a new menstrual tampon plan for and compile a 510(k) premarket notification, FDA provides a device-specific guidance (dated 2005) that delineates the specific kinds of information and data needed to support the tampon application (<xref ref-type="bibr" rid="B4">4</xref>). FDA also provides substantial general guidance for developing its arguments for <italic>substantial equivalence</italic> in the preparation of a 510(k) premarket notification (<xref ref-type="bibr" rid="B5">5</xref>). The manufacturer should carefully consider and apply the guidance from both documents, as well as follow the 510(k) regulation (<xref ref-type="bibr" rid="B6">6</xref>) itself that spells out the basic format and requirements for a 510(k) submission.</p>
<p>Looking first at FDA&#x0027;s 2005 guidance document for tampon 510(k) submissions, a manufacturer sees that FDA expects the following information:
<list list-type="simple">
<list-item><label>&#x25A1;</label><p><italic>Description of the Menstrual Tampon</italic>, including the tampon design and dimensions, tampon absorbency, and a full accounting of all component materials of the tampon, including additives.</p></list-item>
<list-item><label>&#x25A1;</label><p><italic>Potential Risks to Health</italic> Attributed to Use of Menstrual Tampons</p></list-item>
</list>The manufacturer is expected to delineate any and all potential risks from tampon use and list the mitigations to address each risk. In Table 3 of its tampon guidance (p. 27) (<xref ref-type="bibr" rid="B4">4</xref>), FDA identifies known risks associated with tampon use and provides recommended measures to mitigate those risks. These risks include adverse tissue reaction, vaginal injury, vaginal infection and toxic shock syndrome (TSS). Manufacturers should use this guidance to prepare its own Risk Analysis table, including any other information it may be aware of.
<list list-type="simple">
<list-item><label>&#x25A1;</label><p><italic>Performance Characteristics</italic> of the Menstrual Tampon</p></list-item>
</list>Per its 2005 guidance, FDA expects to see the results from the following performance testing:
<list list-type="simple">
<list-item><label>&#x25CB;</label><p><italic>Tampon Absorbency</italic> The test methodology for tampon absorbency (also called &#x201C;syngyna testing&#x201D;) is specified in 21 CFR 801.430(f). Labeling for tampon absorbency must comply with this regulation. See further below.</p></list-item>
<list-item><label>&#x25CB;</label><p><italic>Chemical Residues</italic> (testing to show the tampon is free of dioxins and any pesticide and herbicide residues)</p></list-item>
<list-item><label>&#x25CB;</label><p><italic>Physical testing of String Strength, Fiber Shedding and Tampon Integrity</italic></p></list-item>
</list>
<list list-type="simple">
<list-item><label>&#x25A1;</label><p><italic>Material Safety</italic> Results from Preclinical Toxicological Testing</p></list-item>
</list>To determine the types of toxicological testing needed to establish the material safety of a medical device, FDA relies on an international standard, ISO 10993, entitled &#x201C;Biological Evaluation of Medical Devices &#x2013; Evaluation and Testing within a Risk Management Process&#x201D; (<xref ref-type="bibr" rid="B7">7</xref>). Use of this standard begins with Part 1 that provides an algorithm for choosing the appropriate toxicological tests for any given medical device, depending on the nature of tissue exposure and the duration of exposure. In 2020, FDA published guidance on how this international standard may be used to support material safety testing (<xref ref-type="bibr" rid="B8">8</xref>). In its tampon-specific guidance document, FDA lists the specific tests that are expected (below). The reference in ISO 10993 for the methodology for each toxicological test is given in parenthesis.
<list list-type="simple">
<list-item><label>&#x25CB;</label><p>cytotoxicity (ISO 10993-5)</p></list-item>
<list-item><label>&#x25CB;</label><p>sensitization (ISO 10993-10)</p></list-item>
<list-item><label>&#x25CB;</label><p>vaginal irritation (ISO 10993-10)</p></list-item>
<list-item><label>&#x25CB;</label><p>local effects after implantation (ISO 10993-6)</p></list-item>
</list>An experienced, credentialed laboratory is important for the conduct of such testing. Other possible material safety risks such as acute, subchronic and chronic toxicity, reproductive/developmental toxicity and carcinogenicity may be addressed using a risk analysis approach that obviates the need for further testing. A trained toxicologist is necessary for such a risk analysis, as well as for the review and analysis of the results of the toxicological testing that was done.
<list list-type="simple">
<list-item><label>&#x25A1;</label><p>Risk of <italic>Toxic Shock Syndrome (TSS)</italic> and Preclinical <italic>Microbiological Testing</italic></p></list-item>
</list>FDA also expects the manufacturer to evaluate the potential of a menstrual tampon to determine whether it enhances the growth of <italic>Staphylococcus aureus</italic>, increases production of TSS Toxin-1, or alters the growth of normal vaginal microflora. Such testing should be conducted by an experienced laboratory.
<list list-type="simple">
<list-item><label>&#x25A1;</label><p><italic>Clinical Studies</italic>, <italic>if needed</italic></p></list-item>
</list>Premarket clinical studies are rarely, if ever, needed to support a 510(k) premarket notification for a menstrual tampon. However, if necessary, FDA has provided substantial guidance on the design of clinical studies for medical devices, most notably its 2013 guidance document, entitled &#x201C;<italic>Design Considerations for Pivotal Clinical Investigations for Medical Devices</italic>&#x201D; (<xref ref-type="bibr" rid="B9">9</xref>). Before initiating a clinical study, manufacturers are strongly encouraged to consult with FDA on the key elements of any such study. FDA also provides a guidance document on how to conduct such early interactions with the agency (<xref ref-type="bibr" rid="B10">10</xref>).
<list list-type="simple">
<list-item><label>&#x25A1;</label><p><italic>Labeling</italic> For menstrual tampons, two labeling regulations apply: (1) a general labeling regulation that applies to all medical devices (<xref ref-type="bibr" rid="B11">11</xref>), and (2) a tampon-specific regulation (<xref ref-type="bibr" rid="B12">12</xref>) providing exactly what should be contained in tampon labeling about tampon absorbency and the risk of toxic shock syndrome (TSS). This latter regulation also provides the methodology for the absorbency test (sometimes called &#x201C;syngyna test&#x201D;) to determine tampon absorbency for the labeling.</p></list-item>
</list>In preparation for its submission of a 510(k) premarket notification, a manufacturer should then compile and organize all of the above information&#x2014;both descriptive information, as well as results and analysis from the various studies&#x2014;to cogently demonstrate that the new tampon is <italic>substantially equivalent</italic> to a legally marketed menstrual tampon already on the US market.</p>
<p>To further help medical device developers, FDA posts information on each 510(k) decision it makes, including the SE determination letter, an indications for use sheet, and&#x2014;typically&#x2014;a brief summary of information supporting the 510(k) submission. For regulatory perspective, it can be very useful to review that historical information (<xref ref-type="bibr" rid="B13">13</xref>).</p>
<p>In its 2014 510(k) guidance on how to evaluate <italic>substantial equivalence</italic>, FDA explains how such arguments are made. To help manufacturers with this, the guidance document includes a substantial equivalence logic flowchart to show how the decision-making works (diagram below) (<xref ref-type="bibr" rid="B5">5</xref>).</p>
<p>Regarding use of the flowchart in <xref ref-type="fig" rid="F1">Figure&#x00A0;1</xref>, the FDA guidance emphasizes that the &#x201C;&#x2026;flowchart is NOT [<italic>emphasis added</italic>] intended to be used as a &#x2018;stand-alone&#x2019; document and should only be considered in conjunction with the accompanying text in this guidance.&#x201D; The flowchart and accompanying text should include all appropriate references to the context of each critical decision point.</p>
<fig id="F1" position="float"><label>Figure 1</label>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="frph-05-1224421-g001.tif"/>
</fig>
<p>When the 510(k) premarket notification is received, the statute provides 90 days for the agency to complete its review. FDA may break this 90-day review time into parts, putting the document &#x201C;on hold&#x201D; to ask certain follow-up questions. The manufacturer should carefully consider the questions and provide full response. FDA contact information is provided, and if anything is unclear, manufacturers are encouraged to connect directly with the reviewer.</p>
</sec>
<sec id="s3"><title>Bringing a vaginal pessary to market</title>
<p>Bringing a vaginal pessary to market would follow a regulatory pathway similar to that described above for menstrual tampons. Again, the manufacturer (or developer) must submit a <italic>510(k) premarket notification</italic> to the FDA, following the prescribed regulations and guidance. The submission must provide information showing that the new vaginal pessary is <italic>substantially equivalent</italic>, in terms of safety and effectiveness, to another similar pessary already legally on the market, the so-called <italic>predicate device</italic>.</p>
<p>While FDA has not produced a device-specific guidance document on vaginal pessaries, many of the same principles used for the tampon apply to the vaginal pessary. The general guidance for developing arguments for substantial equivalence, discussed above, apply here (<xref ref-type="bibr" rid="B14">14</xref>). As with the tampons, the manufacturer should carefully consider this guidance and follow the 510(k) regulation (<xref ref-type="bibr" rid="B15">15</xref>) itself that spells out the basic format and requirements for a 510(k) submission.</p>
<p>When preparing a 510(k) premarket notification for a new vaginal pessary and considering the types of information needed to support an argument for substantial equivalence, the manufacturer (or developer) must also consider the intended use of the pessary. Unlike the tampon, a vaginal pessary&#x2014;depending on its design and the manufacturer&#x0027;s intention&#x2014;may be used to manage urinary incontinence and/or pelvic organ prolapse. Again, depending on design and manufacturer intention, a new pessary might be available over-the-counter or as a prescription-only device. It might require physician evaluation, need for fitting, insertion and removal, or it might be designed so that the user could insert it and remove it herself. The pessary might be intended as single-use disposable device, for a short period of time, or for longer-term use, reusable with instructions for cleaning. When building the argument for substantial equivalence, the manufacturer must consider all of these device features in the context of the 510(k) SE flowchart (<xref ref-type="fig" rid="F1">Figure&#x00A0;1</xref>), especially as it relates to the predicate device, the indication for use and intended use and whether that might trigger the need for clinical data.</p>
<p>Using the tampon 510(k) submission (described above) as a model, a manufacturer should follow a similar path and can expect that FDA will expect the following information for a new pessary:
<list list-type="simple">
<list-item><label>&#x25A1;</label><p><italic>Description of the Vaginal Pessary</italic>, including the pessary design and dimensions, insertion features, and a full accounting of all component materials, including additives.</p></list-item>
<list-item><label>&#x25A1;</label><p><italic>Potential Risks to Health</italic> attributed to Use of Vaginal Pessary</p></list-item>
</list>FDA has not developed a device-specific guidance document on vaginal pessaries, so the manufacturer must conduct its own independent risk analysis, delineating all potential risks from pessary use and the mitigations to address each risk. Many of these potential risks are obvious, e.g., adverse tissue reaction, vaginal injury, vaginal infection and toxic shock syndrome (TSS). In its independent risk analysis, manufacturers should include any other information it may be aware of.
<list list-type="simple">
<list-item><label>&#x25A1;</label><p><italic>Performance Characteristics</italic> of the Vaginal Pessary</p></list-item>
</list>Considering FDA&#x0027;s general guidance, as well as the types of information FDA expects for tampons, manufacturers should test the performance specifications of the pessary in the context of the risk analysis and identified mitigations. Such physical bench testing might include:
<list list-type="simple">
<list-item><label>&#x25FE;</label><p>applicator (if any) insertion and removal force</p></list-item>
<list-item><label>&#x25FE;</label><p>core properties of the finished pessary and applicator (if any), e.g., dimensions, weight, material properties, compression characteristics</p></list-item>
<list-item><label>&#x25FE;</label><p>removal string (if any) detachment force and string integrity</p></list-item>
</list>
<list list-type="simple">
<list-item><label>&#x25A1;</label><p><italic>Material Safety</italic> &#x007C; Results from Preclinical Toxicological Testing</p></list-item>
</list>As with the tampon, the manufacturer of a new vaginal pessary should apply the international standard, ISO 10993, Part 1 (<xref ref-type="bibr" rid="B16">16</xref>), to determine the appropriate toxicological tests that should be undertaken. For the vaginal pessary, considering its mucosal contact, possible indirect blood contact for long-term and/or repeated use duration, the following tests are recommended, at a minimum:
<list list-type="simple">
<list-item><label>&#x25CB;</label><p>cytotoxicity (ISO 10993-5)</p></list-item>
<list-item><label>&#x25CB;</label><p>sensitization (ISO 10993-10)</p></list-item>
<list-item><label>&#x25CB;</label><p>vaginal irritation (ISO 10993-10)</p></list-item>
<list-item><label>&#x25CB;</label><p>local effects after implantation (ISO 10993-6)</p></list-item>
</list>At this stage of the process, a trained toxicologist should be engaged to evaluate the pessary and determine the full battery of toxicological testing. An experienced, credentialed laboratory is important for the conduct of such testing. As with the tampon, other possible material safety risks such as acute, subchronic and chronic toxicity, reproductive/developmental toxicity and carcinogenicity may be addressed using a risk analysis approach that obviates the need for further testing. A trained toxicologist is necessary for such a risk analysis, as well as for the review and analysis of the results of the toxicological testing that was done.
<list list-type="simple">
<list-item><label>&#x25A1;</label><p>Risk of <italic>Toxic Shock Syndrome (TSS)</italic> and Preclinical <italic>Microbiological Testing</italic></p></list-item>
</list>FDA also expects the manufacturer of a new vaginal pessary to determine its potential for enhancing the growth of <italic>Staphylococcus aureus</italic>, or increasing production of TSS Toxin-1, or altering the growth of normal vaginal microflora. Such testing should be conducted by an experienced laboratory; appropriate expertise should be used in selecting such a laboratory.
<list list-type="simple">
<list-item><label>&#x25A1;</label><p><italic>Clinical Studies</italic>, <italic>if needed</italic></p></list-item>
</list>Typically, no clinical studies will be needed to support a 510(k) for a vaginal pessary. However, if new use features are introduced, e.g., OTC/self-administration, it may be necessary to conduct small clinical validation studies to evaluate label comprehension, self-selection, and self-administration. And, depending on the intended use of the pessary, the primary study endpoint of such a clinical study might be prolapse stage (for pelvic organ prolapse) or number of incontinence pads needed (for urinary incontinence). The manufacturer should consider whether an early consultation with FDA staff would be helpful to ensure the clinical study design will answer the questions that the agency is likely to have. See FDA guidance on Q-submissions (<xref ref-type="bibr" rid="B10">10</xref>). It might also be helpful to re-visit FDA&#x0027;s 2013 general guidance document on the design of clinical studies for medical devices, discussed earlier.
<list list-type="simple">
<list-item><label>&#x25A1;</label><p><italic>Labeling</italic> While there is no device-specific labeling regulation for vaginal pessaries, manufacturers must comply with the general labeling regulation for medical devices (21 CFR 801) (<xref ref-type="bibr" rid="B11">11</xref>).</p></list-item>
</list>If and when a manufacturer receives a decision letter from FDA with a determination of substantial equivalence, by statute that is&#x2014;in effect&#x2014;regulatory permission to market the device in the US.</p>
</sec>
<sec id="s4"><title>510(k) premarket notification &#x007C; administrative items to consider</title>
<list list-type="simple">
<list-item><label>&#x25FE;</label><p>Format of a 510(k) submission. FDA has provided general guidance on the basic format of a 510(k) submission (<xref ref-type="bibr" rid="B17">17</xref>).</p></list-item>
<list-item><label>&#x25FE;</label><p>90-day statutory review timeline. By statute, FDA has 90-days to complete its review of a 510(k) submission. Depending on questions the FDA review team may have, the 90-days may be split between the initial review and a subsequent review of FDA questions.</p></list-item>
<list-item><label>&#x25FE;</label><p>Submission of a 510(k) and correspondence with FDA. For FDA to successfully complete its review, the manufacturer must carefully and thoroughly respond to all FDA concerns in a timely manner. If there is any uncertainty about what is needed, the manufacturer is encouraged to contact the FDA review team and clarify what FDA is looking for.</p></list-item>
<list-item><label>&#x25FE;</label><p>User fees. Submission of a 510(k) is governed by the Medical Device User Fee Amendments (MDUFA) (<xref ref-type="bibr" rid="B18">18</xref>). In FY2023, the user fee for a 510(k) submission is &#x0024;19,870USD (&#x0024;4,967USD for certified small business).</p></list-item>
</list>
<p>It also important to recognize that FDA employs a comprehensive set of postmarket controls to ensure the continued safety and effectiveness of the device in the market and use settings. Perhaps the most important are good manufacturing practices (GMPs), as spelled out in the Quality Systems regulation (21 CFR Part 820). Other relevant controls include annual registration of device manufacturing facilities, listing of devices, labeling, mandatory device reporting (adverse events) and prohibitions against misbranding (false or misleading in any particular) and adulteration (e.g., corrupted or debased by incorporating an impure or spurious substance). While these regulatory controls are critical to the continued safety and effectiveness of menstrual tampons and vaginal pessaries, this article will not go into the details of those controls.</p>
</sec>
<sec id="s5" sec-type="conclusions"><title>Conclusion</title>
<p>In summary, in the United States, menstrual tampons and vaginal pessaries are medical devices, subject to a set of premarket and postmarket regulations. Practicing clinicians are often the idea-source for innovative improvements of these products. When working with a product development team, these clinicians should be cognizant of the regulatory environment and be prepared to help their teams accordingly. It is hoped that this article will serve as a useful starting point for clinicians embarking on a program contributing to a 510(k) premarket notification for a menstrual tampon or a vaginal pessary. Clinicians new to such programs seeking marketing authorization from FDA would be well advised to work closely with the regulatory specialist on the product development team before beginning on any clinical trials or initiating contact with FDA personnel.</p>
</sec>
</body>
<back>
<sec id="s7" sec-type="data-availability"><title>Data availability statement</title>
<p>The original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding author.</p>
</sec>
<sec id="s8" sec-type="author-contributions"><title>Author contributions</title>
<p>The author confirms being the sole contributor of this work and has approved it for publication.</p>
</sec>
<sec id="s9" sec-type="COI-statement"><title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec id="s10" sec-type="disclaimer"><title>Publisher&#x0027;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ref-list><title>References</title>
<ref id="B1"><label>1.</label><citation citation-type="other"><comment>P.L. 94-295 | 1976 Medical Device Amendments, amending the Federal Food, Drug and Cosmetic Act</comment>.</citation></ref>
<ref id="B2"><label>2.</label><citation citation-type="other"><comment>CFR - Code of Federal Regulations, Title 21</comment>. <ext-link ext-link-type="uri" xlink:href="https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfcfr/cfrsearch.cfm">https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfcfr/cfrsearch.cfm</ext-link>.</citation></ref>
<ref id="B3"><label>3.</label><citation citation-type="other"><comment>Available at:</comment> <ext-link ext-link-type="uri" xlink:href="https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance">https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance</ext-link>.</citation></ref>
<ref id="B4"><label>4.</label><citation citation-type="other"><comment>Menstrual tampons &#x0026; pads &#x007C; information for premarket notification submissions (510(k)s) &#x007C; guidance for industry &#x0026; FDA staff (2005). Available at:</comment> <ext-link ext-link-type="uri" xlink:href="https://www.fda.gov/files/medical%20devices/published/Menstrual-Tampons-and-Pads&#x2013;Information-for-Premarket-Notification-Submissions-%28510%28k%29s%29&#x2014;Guidance-for-Industry-and-FDA-Staff-%28PDF%29.pdf">https://www.fda.gov/files/medical&#x0025;20devices/published/Menstrual-Tampons-and-Pads&#x2013;Information-for-Premarket-Notification-Submissions-&#x0025;28510&#x0025;28k&#x0025;29s&#x0025;29&#x2014;Guidance-for-Industry-and-FDA-Staff-&#x0025;28PDF&#x0025;29.pdf</ext-link>.</citation></ref>
<ref id="B5"><label>5.</label><citation citation-type="other"><comment>The 510(k) program: evaluating substantial equivalence in a 510(k) premarket notification (2014). Available at:</comment> <ext-link ext-link-type="uri" xlink:href="https://www.fda.gov/media/82395/download">https://www.fda.gov/media/82395/download</ext-link>.</citation></ref>
<ref id="B6"><label>6.</label><citation citation-type="other"><comment>CFR 807, subpart E &#x007C; premarket notification procedures. Available at:</comment> <ext-link ext-link-type="uri" xlink:href="https://www.ecfr.gov/current/title-21/chapter-I/subchapter-H/part-807/subpart-E">https://www.ecfr.gov/current/title-21/chapter-I/subchapter-H/part-807/subpart-E</ext-link>.</citation></ref>
<ref id="B7"><label>7.</label><citation citation-type="other"><comment>ISO 10993-1:2018 biological evaluation of medical devices &#x2013; part 1: evaluation and testing within a risk management process. Available at:</comment> <ext-link ext-link-type="uri" xlink:href="https://www.iso.org/standard/68936.html">https://www.iso.org/standard/68936.html</ext-link>.</citation></ref>
<ref id="B8"><label>8.</label><citation citation-type="other"><comment>ISO 10993-1 use of 10993, part 1, evaluation and testing within a risk management process: guidance for industry and FDA staff (2020). Available at:</comment> <ext-link ext-link-type="uri" xlink:href="https://www.fda.gov/regulatory-information/search-fda-guidance-documents/use-international-standard-iso-10993-1-biological-evaluation-medical-devices-part-1-evaluation-and">https://www.fda.gov/regulatory-information/search-fda-guidance-documents/use-international-standard-iso-10993-1-biological-evaluation-medical-devices-part-1-evaluation-and</ext-link>.</citation></ref>
<ref id="B9"><label>9.</label><citation citation-type="other"><comment>Design considerations for pivotal clinical investigations for medical devices &#x007C; guidance for industry, clinical investigators, IRBs and FDA staff (2013). Available at:</comment> <ext-link ext-link-type="uri" xlink:href="https://www.fda.gov/regulatory-information/search-fda-guidance-documents/design-considerations-pivotal-clinical-investigations-medical-devices">https://www.fda.gov/regulatory-information/search-fda-guidance-documents/design-considerations-pivotal-clinical-investigations-medical-devices</ext-link>.</citation></ref>
<ref id="B10"><label>10.</label><citation citation-type="other"><comment>FDA&#x2019;s Q-submission guidance &#x007C; feedback &#x0026; meetings (2021). Available at:</comment> <ext-link ext-link-type="uri" xlink:href="https://www.fda.gov/media/114034/download">https://www.fda.gov/media/114034/download</ext-link>.</citation></ref>
<ref id="B11"><label>11.</label><citation citation-type="other"><comment>CFR 801. Available at:</comment> <ext-link ext-link-type="uri" xlink:href="https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfCFR/CFRSearch.cfm?CFRPart=801">https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfCFR/CFRSearch.cfm?CFRPart&#x003D;801</ext-link>.</citation></ref>
<ref id="B12"><label>12.</label><citation citation-type="other"><comment>CFR 801.430. Available at:</comment> <ext-link ext-link-type="uri" xlink:href="https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfCFR/CFRSearch.cfm?fr=801.430">https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfCFR/CFRSearch.cfm?fr&#x003D;801.430</ext-link>.</citation></ref>
<ref id="B13"><label>13.</label><citation citation-type="other"><comment>Available at:</comment> <ext-link ext-link-type="uri" xlink:href="https://www.fda.gov/medical-devices/device-approvals-denials-and-clearances/510k-clearances">https://www.fda.gov/medical-devices/device-approvals-denials-and-clearances/510k-clearances</ext-link>.</citation></ref>
<ref id="B14"><label>14.</label><citation citation-type="other"><comment>The 510(k) program: evaluating substantial equivalence in a 510(k) premarket notification (2014)</comment>.</citation></ref>
<ref id="B15"><label>15.</label><citation citation-type="other"><comment>CFR 807, subpart E &#x007C; premarket notification procedures</comment>.</citation></ref>
<ref id="B16"><label>16.</label><citation citation-type="other"><comment>Available at:</comment> <ext-link ext-link-type="uri" xlink:href="https://www.iso.org/standard/68936.html">https://www.iso.org/standard/68936.html</ext-link>.</citation></ref>
<ref id="B17"><label>17.</label><citation citation-type="other"><comment>Format for traditional and abbreviated 510(k)s: guidance for industry and FDA staff (2019). Available at:</comment> <ext-link ext-link-type="uri" xlink:href="https://www.fda.gov/regulatory-information/search-fda-guidance-documents/format-traditional-and-abbreviated-510ks">https://www.fda.gov/regulatory-information/search-fda-guidance-documents/format-traditional-and-abbreviated-510ks</ext-link>.</citation></ref>
<ref id="B18"><label>18.</label><citation citation-type="other"><comment>Medical device user fee amendments (MDUFA). Available at:</comment> <ext-link ext-link-type="uri" xlink:href="https://www.fda.gov/industry/fda-user-fee-programs/medical-device-user-fee-amendments-mdufa">https://www.fda.gov/industry/fda-user-fee-programs/medical-device-user-fee-amendments-mdufa</ext-link>.</citation></ref></ref-list>