<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Public Health</journal-id>
<journal-title>Frontiers in Public Health</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Public Health</abbrev-journal-title>
<issn pub-type="epub">2296-2565</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fpubh.2022.981019</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Public Health</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Comparative studies of deep learning segmentation models for left ventricle segmentation</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name><surname>Shoaib</surname> <given-names>Muhammad Ali</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/1688424/overview"/>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name><surname>Lai</surname> <given-names>Khin Wee</given-names></name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<xref ref-type="corresp" rid="c001"><sup>&#x0002A;</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/1409678/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Chuah</surname> <given-names>Joon Huang</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/1889834/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Hum</surname> <given-names>Yan Chai</given-names></name>
<xref ref-type="aff" rid="aff4"><sup>4</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/1513945/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Ali</surname> <given-names>Raza</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/1737795/overview"/>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name><surname>Dhanalakshmi</surname> <given-names>Samiappan</given-names></name>
<xref ref-type="aff" rid="aff5"><sup>5</sup></xref>
<xref ref-type="corresp" rid="c002"><sup>&#x0002A;</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/1515189/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Wang</surname> <given-names>Huanhuan</given-names></name>
<xref ref-type="aff" rid="aff6"><sup>6</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/1782733/overview"/>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name><surname>Wu</surname> <given-names>Xiang</given-names></name>
<xref ref-type="aff" rid="aff6"><sup>6</sup></xref>
<xref ref-type="corresp" rid="c003"><sup>&#x0002A;</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/1579254/overview"/>
</contrib>
</contrib-group>
<aff id="aff1"><sup>1</sup><institution>Department of Electrical Engineering, Faculty of Engineering, Universiti Malaya</institution>, <addr-line>Kuala Lumpur</addr-line>, <country>Malaysia</country></aff>
<aff id="aff2"><sup>2</sup><institution>Faculty of Information and Communication Technology, BUITEMS</institution>, <addr-line>Quetta</addr-line>, <country>Pakistan</country></aff>
<aff id="aff3"><sup>3</sup><institution>Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya</institution>, <addr-line>Kuala Lumpur</addr-line>, <country>Malaysia</country></aff>
<aff id="aff4"><sup>4</sup><institution>Department of Mechatronics and Biomedical Engineering, Lee Kong Chian Faculty of Engineering and Science, Universiti Tunku Abdul Rahman</institution>, <addr-line>Kajang</addr-line>, <country>Malaysia</country></aff>
<aff id="aff5"><sup>5</sup><institution>Department of Electronics and Communication Engineering, Faculty of Engineering and Technology, SRM Institute of Science and Technology</institution>, <addr-line>Kattankulathur</addr-line>, <country>India</country></aff>
<aff id="aff6"><sup>6</sup><institution>Institute of Medical Information Security, Xuzhou Medical University</institution>, <addr-line>Xuzhou</addr-line>, <country>China</country></aff>
<author-notes>
<fn fn-type="edited-by"><p>Edited by: Chin-Shiuh Shieh, National Kaohsiung University of Science and Technology, Taiwan</p></fn>
<fn fn-type="edited-by"><p>Reviewed by: Amir Faisal, Sumatra Institute of Technology, Indonesia; Aneta Poniszewska-Maranda, Lodz University of Technology, Poland</p></fn>
<corresp id="c001">&#x0002A;Correspondence: Khin Wee Lai <email>lai.khinwee&#x00040;um.edu.my</email></corresp>
<corresp id="c002">Samiappan Dhanalakshmi <email>dhanalas&#x00040;srmist.edu.in</email></corresp>
<corresp id="c003">Xiang Wu <email>wuxiang&#x00040;xzhmu.edu.cn</email></corresp>
<fn fn-type="other" id="fn001"><p>This article was submitted to Digital Public Health, a section of the journal Frontiers in Public Health</p></fn></author-notes>
<pub-date pub-type="epub">
<day>25</day>
<month>08</month>
<year>2022</year>
</pub-date>
<pub-date pub-type="collection">
<year>2022</year>
</pub-date>
<volume>10</volume>
<elocation-id>981019</elocation-id>
<history>
<date date-type="received">
<day>29</day>
<month>06</month>
<year>2022</year>
</date>
<date date-type="accepted">
<day>08</day>
<month>08</month>
<year>2022</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x000A9; 2022 Shoaib, Lai, Chuah, Hum, Ali, Dhanalakshmi, Wang and Wu.</copyright-statement>
<copyright-year>2022</copyright-year>
<copyright-holder>Shoaib, Lai, Chuah, Hum, Ali, Dhanalakshmi, Wang and Wu</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license> </permissions>
<abstract>
<p>One of the primary factors contributing to death across all age groups is cardiovascular disease. In the analysis of heart function, analyzing the left ventricle (LV) from 2D echocardiographic images is a common medical procedure for heart patients. Consistent and accurate segmentation of the LV exerts significant impact on the understanding of the normal anatomy of the heart, as well as the ability to distinguish the aberrant or diseased structure of the heart. Therefore, LV segmentation is an important and critical task in medical practice, and automated LV segmentation is a pressing need. The deep learning models have been utilized in research for automatic LV segmentation. In this work, three cutting-edge convolutional neural network architectures (SegNet, Fully Convolutional Network, and Mask R-CNN) are designed and implemented to segment the LV. In addition, an echocardiography image dataset is generated, and the amount of training data is gradually increased to measure segmentation performance using evaluation metrics. The pixel&#x00027;s accuracy, precision, recall, specificity, Jaccard index, and dice similarity coefficients are applied to evaluate the three models. The Mask R-CNN model outperformed the other two models in these evaluation metrics. As a result, the Mask R-CNN model is used in this study to examine the effect of training data. For 4,000 images, the network achieved 92.21% DSC value, 85.55% Jaccard index, 98.76% mean accuracy, 96.81% recall, 93.15% precision, and 96.58% specificity value. Relatively, the Mask R-CNN outperformed other architectures, and the performance achieves stability when the model is trained using more than 4,000 training images.</p></abstract>
<kwd-group>
<kwd>Convolutional Neural Network (CNN)</kwd>
<kwd>segmentation</kwd>
<kwd>image processing</kwd>
<kwd>deep learning</kwd>
<kwd>left ventricle (LV)</kwd>
<kwd>echocardiography</kwd>
</kwd-group>
<counts>
<fig-count count="8"/>
<table-count count="2"/>
<equation-count count="6"/>
<ref-count count="47"/>
<page-count count="11"/>
<word-count count="6380"/>
</counts>
</article-meta>
</front>
<body>
<sec sec-type="intro" id="s1">
<title>Introduction</title>
<p>Cardiovascular diseases (CVDs) are the leading cause of death throughout the world (<xref ref-type="bibr" rid="B1">1</xref>). Every third person is affected by CVDs each year, according to World Health Organization (WHO) statistics (<xref ref-type="bibr" rid="B2">2</xref>, <xref ref-type="bibr" rid="B3">3</xref>). The gold standard in diagnostic imaging of the heart is echocardiography and cardiac magnetic resonance imaging (CMRI). CMRI provides 3-dimensional visualization of the heart with a complete analysis of cardiac structure, whereas echocardiography can examine the function and structure of the heart (<xref ref-type="bibr" rid="B4">4</xref>).</p>
<p>However, when compared to echocardiography, CMRI has several disadvantages, including limited availability, time consumption, and cost (<xref ref-type="bibr" rid="B5">5</xref>). Echocardiography, on the other hand, is a non-invasive, low-cost, and non-ionization radiation technique, making it the most important and accessible imaging modality for cardiac analysis (<xref ref-type="bibr" rid="B6">6</xref>). The assessment of the left ventricle (LV) structures and functions is an important study in cardiac analysis (<xref ref-type="bibr" rid="B7">7</xref>). Estimating LV size is necessary for calculating ventricular volume, ejection fraction, wall motion irregularities, and myocardial thickness (<xref ref-type="bibr" rid="B8">8</xref>). It identifies high-risk patients and predicts future cardiovascular events (<xref ref-type="bibr" rid="B9">9</xref>). As a result, the proper detection of the LV boundary depends on the LV segmentation, which also makes the analysis and diagnosis simple. On the other hand, manual LV detection generally takes a long time, is labor-intensive, and heavily relies on the experience of cardiologists (<xref ref-type="bibr" rid="B10">10</xref>). The structural characteristics of ventricles make it a difficult undertaking to segment them. Compared to segmenting organs like the liver or kidney, it is more challenging (<xref ref-type="bibr" rid="B11">11</xref>&#x02013;<xref ref-type="bibr" rid="B13">13</xref>). In order to be quicker, more accurate, and less operator-dependent, automatic LV segmentation from echocardiography is required.</p>
<p>Deep learning is widely employed in automatic image segmentation and also in medical image processing. Due to its superior performance, deep learning has emerged as the technology that receives the most attention. Taking into account the significance of deep learning, this article aims to make a comparative analysis of three well known deep learning segmentation architectures, SegNet, FCN, and MaskR-CNN, for LV segmentation. The results obtained by comparing the performance of these algorithms on the same dataset can help to understand these models and to determine which method of image segmentation is most effective for LV segmentation.</p></sec>
<sec id="s2">
<title>Related work</title>
<p>Various LV segmentation methods, including deformable models, statistical models (<xref ref-type="bibr" rid="B14">14</xref>), and machine learning approaches, have been successfully used in recent years. Due to the flexibility in shape representation, deformable models are the most used method for segmentation in ultrasound pictures (<xref ref-type="bibr" rid="B15">15</xref>&#x02013;<xref ref-type="bibr" rid="B17">17</xref>). To achieve the intended shape, it employs predetermined curves or surfaces that change the shape under the influence of internal forces. Additionally, these deformable models are used to create LV segmentation (<xref ref-type="bibr" rid="B18">18</xref>, <xref ref-type="bibr" rid="B19">19</xref>). The performance of deformable models is enhanced using a variety of transformation techniques. A pSnake approach based on 1-D Hilbert transformation was proposed by Alexandria et al. (<xref ref-type="bibr" rid="B20">20</xref>). For reliable and efficient segmentation, S. Zhang presented a deformable framework (<xref ref-type="bibr" rid="B21">21</xref>). The model can handle significant faults and reserve shape details. The segmentation of the four main views, including the left ventricle (LV), using 2D echocardiography also uses deformable models (<xref ref-type="bibr" rid="B22">22</xref>). A few new parameters were included in the energy function to further enhance the performance of deformable models and achieve high accuracy (<xref ref-type="bibr" rid="B23">23</xref>). A new energy function for segmenting the whole myocardium in various directions was defined in the enhanced version of (<xref ref-type="bibr" rid="B22">22</xref>). The deformable models are comprehensive and appropriate for segmenting LV, but they have certain restrictions when it comes to choosing the right initialization since most of the methods necessitate human decision-making during the initialization process. These previous models&#x00027; validity negates the effectiveness and capacity of such strategies. In such circumstances, the parameters must be reparametrized robustly to recover the boundary accurately.</p>
<p>The statistical deformable models are generative models that, through optimization during the fitting process, recover the parametric description of the particular object. Active Shape Models (ASM) and Active Appearance Models (AAM) have been the most widely utilized techniques in echocardiography (AAM). The behavior of the model is created during the training phase by manually tracing over segmented data. The geometry and visual representation of the heart anatomy were all included in the final model. A reliable segmentation of cardiac pictures in terms of space and/or time is ensured by this single model (<xref ref-type="bibr" rid="B24">24</xref>). Based on AAM, it is suggested to automatically segment the left ventricle (LV) using a 3D echocardiography approach and to assess the shape and texture of model generalization. The suggested model accurately extrapolates the shape model. However, the texture model struggled in situations where AAM matching (<xref ref-type="bibr" rid="B25">25</xref>) was constrained. Carminati et al. (<xref ref-type="bibr" rid="B26">26</xref>) created a shape model of the LV using the statistical model on echocardiography data, which was then applied to MRI scans. These statistical models needed several beneficial training examples, and from these samples, the model creates the shape of the item. These models need initialization and shape assumptions in addition to a large number of useful annotated photos. The automatic segmentation of LV is further constrained by its appearance.</p>
<p>Recent research has shown that machine learning approaches are useful for LV segmentation because they do not require initialization and do not rely on assumptions about shape and appearance. Methods based on marginal space learning have primarily been considered for accurately locating the myocardial region (<xref ref-type="bibr" rid="B27">27</xref>). Similarly, a border fragment model has been successfully used to identify extracted contours (<xref ref-type="bibr" rid="B28">28</xref>). The random forest-based machine learning approach has been used as a discriminative classifier to describe the association of each voxel to the myocardium (<xref ref-type="bibr" rid="B29">29</xref>) and is a popular machine learning method for LV segmentation (<xref ref-type="bibr" rid="B29">29</xref>&#x02013;<xref ref-type="bibr" rid="B31">31</xref>). Deep learning has attracted attention in image segmentation since it is a completely automatic method (<xref ref-type="bibr" rid="B32">32</xref>&#x02013;<xref ref-type="bibr" rid="B34">34</xref>). Deep learning techniques, such as Convolutional Neural Network (CNN), have been used to segment natural images with remarkable results. Deformable models are also used in conjunction with CNN to segment the LV from 3D echocardiography to determine the Region of Interest (ROI) (<xref ref-type="bibr" rid="B35">35</xref>&#x02013;<xref ref-type="bibr" rid="B37">37</xref>). Deep learning-based architecture &#x0201C;Fully Convolutional Network (FCN)&#x0201D; (<xref ref-type="bibr" rid="B38">38</xref>) is used for LV segmentation in CT images, U-Net on MRI images (<xref ref-type="bibr" rid="B39">39</xref>, <xref ref-type="bibr" rid="B40">40</xref>), U-Net on 2D echocardiography images (<xref ref-type="bibr" rid="B41">41</xref>), and another U-Net-based architecture &#x0201C;Anatomically Constrained Neural Network (ACNN)&#x0201D; (<xref ref-type="bibr" rid="B42">42</xref>) is used for 3D images. Leclerc et al. (<xref ref-type="bibr" rid="B43">43</xref>, <xref ref-type="bibr" rid="B44">44</xref>) investigated the performance of U-Net and the amount of data required to train the network for LV segmentation using U-Net.</p>
<p>Inspired by the performance of deep learning methods, three end-to-end fully automatic segmentation models are designed to segment the LV. Stated below are the main contributions of this paper:</p>
<list list-type="order">
<list-item><p>Implemented the state-of-the-art CNN architectures (SegNet, FCN, and Mask R-CNN) used for image segmentation.</p></list-item>
<list-item><p>Analyzed these CNN architectures by assessing the segmentation mask through evaluation metrics.</p></list-item>
<list-item><p>Determined the trade-off between the amount of data and accuracy using Mask R-CNN architecture.</p></list-item>
<list-item><p>Developed a dataset (for a fair comparison) containing the apical four-chamber view of the heart and binary mask of LV, used for training, validation, and testing the network.</p></list-item>
</list>
<p>Section Introduction introduces the research topic. Section Related work summarizes the literature used for the LV segmentation and the contribution of the article. Section Materials and method describes the dataset employed, the architecture description of CNN models, network training, and the evaluation metrics used to evaluate the performance of these models. Section Discussion presents the results from applying Segnet, FCN, and Mask R-CNN with 1,000 training images, followed by analyzing the performance of Mask R-CNN with increasing training data. The results are discussed in Section Discussion.</p></sec>
<sec sec-type="materials and methods" id="s3">
<title>Materials and methods</title>
<sec>
<title>Dataset</title>
<p>The dataset used in this study was obtained retrospectively from the National Heart Institute in Kuala Lumpur, Malaysia. It is made up of 6,000 apical four-chamber 2D echocardiography images. These images were collected using protocol number RD5/04/15, which was approved by the National Heart Institute&#x00027;s Research Ethics Board in Kuala Lumpur, Malaysia. An ultrasound system (Philips IE33) with an S5-1 (1.0&#x02013;3.0 MHz) transducer was used to perform the 2-D echocardiography. Each image is 800x600 pixels in size, with a resolution of 0.3 mm x 0.3 mm and a frame rate of 30&#x02013;100 Hz. All images were resized to 512 x 512 to remove the extraneous background. One thousand images are used to train all of the models for the comparison of different CNN models. To examine the impact of training data on performance, a dataset with varying numbers of images, 2,000, 3,000, 4,000, and 5,000, is used to train the model. However, the number of test and validation images remains constant (500 test and 500 validation images). Since these test images were not used in the training process, the trained model is tested using unseen data.</p></sec>
<sec>
<title>Network architecture</title>
<p>For LV segmentation, three different CNN models are used: FCN (fully convolutional Network), SegNet (encoder-decoder based), and Mask R-CNN. SegNet is intended to be a fast architecture for pixel-by-pixel semantic segmentation. SegNet&#x00027;s decoder upsamples the low-resolution input provided by previous feature maps. To perform non-linear upsampling, the decoder employs pooling indices computed during the max-pooling step of the corresponding encoder. The FCN, on the other hand, confers several advantages over other models, including the ability to process variable image sizes and handle spatial information. Mask R-CNN was chosen for this study, attributed to its capabilities and robustness for general-purpose object segmentation.</p>
<sec>
<title>Fully convolutional network</title>
<p>For image segmentation, the FCN is a well-known CNN architecture (<xref ref-type="bibr" rid="B45">45</xref>). The network is split into two sections: downsampling and upsampling. Downsampling maps complex image features and downsampling spatial resolutions using convolution operations followed by polling. As shown in <xref ref-type="fig" rid="F1">Figure 1</xref>, the output of this step is of very low resolution. Each pixel in semantic segmentation must be classified as LV or background pixel. The un-pooling operation is performed on the pooling operation&#x00027;s low-resolution output to obtain the output mask with the same resolution as the original image. Un-pooling is the process of converting a single value into a collection of new values. The deconvolution process reduces the input image resolutions which impedes the regeneration of finer details. To overcome this caveat, skip connections are adopted to acquire sufficient information to generate the finer segmentation boundaries.</p>
<fig id="F1" position="float">
<label>Figure 1</label>
<caption><p>FCN architecture.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fpubh-10-981019-g0001.tif"/>
</fig></sec>
<sec>
<title>SegNet</title>
<p>SegNet, one of the popular CNN architectures for segmentation, consists of an encoder and decoder part with a pixel-wise classification layer in the final stage. Object classification is performed by 13 convolutional layers (13-layer VGG network). The output features are passed through batch normalized, followed by ReLU, Max pooling, and stride operations. The decoder layer is designed for each corresponding encoder layer. Hence, the decoder consists of 13 layers. A SoftMax classifier is used at the output of the decoder, yielding the class probabilities of each pixel (<xref ref-type="bibr" rid="B35">35</xref>). The SegNet architecture is shown in <xref ref-type="fig" rid="F2">Figure 2</xref>.</p>
<fig id="F2" position="float">
<label>Figure 2</label>
<caption><p>SegNet architecture.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fpubh-10-981019-g0002.tif"/>
</fig></sec>
<sec>
<title>Mask R-CNN</title>
<p><xref ref-type="fig" rid="F3">Figure 3</xref> depicts the general architecture of Mask R-CNN. The ResNet-50-FPN model and the ResNet-101-FPN model are used in the first part of the framework to extract feature maps from images. The backbone network in the model with ResNet-50-FPN consumes less computational load than ResNet-101. With no changes to the model or training procedure, the ResNet-101-FPN achieves higher accuracy. As a result, ResNet-101-FPN is selected as the framework&#x00027;s backbone network. The input image is processed by the backbone CNN architecture to generate the feature map. This feature map serves as the input for the subsequent stages. The Region Proposal Network (RPN) is the framework&#x00027;s second component, and it is used to extract region proposals. The RPN examines the complete image by sliding window technique and proposes the region that might contain the desired object. These regions and the boxes generated by RPN on the image are called anchors, with around two hundred thousand units of different sizes and aspect ratios. In this research, different scales from the original RPN network were used.</p>
<fig id="F3" position="float">
<label>Figure 3</label>
<caption><p>Mask R-CNN architecture.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fpubh-10-981019-g0003.tif"/>
</fig>
<p>Four different scales containing all possible rectangular boxes were defined: 32 &#x000D7; 32, 64 &#x000D7; 64, 128 &#x000D7; 128, and 256 &#x000D7; 256. Three aspect ratios; 0.5, 1.0, and 2.0 are used for a total of 15 proposals for each pixel. The feature map is passed through a 3x3 convolution layer and subsequently two 1 x 1 convolutional layers. The first 1 x 1 convolutional layer classifies the anchor as foreground (LV) or background, and the second convolution layer coordinates the correction of the anchor. A small convolutional network determines the object possibility of each anchor to calculate the anchor score. The top N high score boxes were chosen as ROI based on this score. If multiple anchors overlap, the non-max suppression technique is applied to keep the one with the highest foreground score. The RPN&#x00027;s bounding box refinement steps allow for ROI box size adjustment. Nonetheless, sigmoid classifiers are limited to inputs of a fixed size. As a result, ROI-Align is required, which takes the object proposal and uses bilinear interpolation to compute the feature map values.</p>
<p>The class and ROI mask are processed by separated network heads. In this case, only one ROI is defined, along with foreground and background (FG/BG) classes. With a single ROI, fully connected layers are used to predict the class object. The class of an object is determined by the class-entropy loss function, which calculates class loss. Due to a major single segmentation class, a sigmoid function is used as a classifier (LV).</p>
<p>A convolutional network is used in ROI to generate the mask. Each pixel in ROI is subjected to the sigmoid function, which produces an output mask. Each ground-truth mask and predicted mask were defined as 28 28 during training. This small mask size aids in keeping the mask branch at a low resolution to conserve memory. The predicted masks were scaled up to the size of the original ROI at the output.</p></sec></sec>
<sec>
<title>Network training</title>
<p>The network is trained on a workstation equipped with a Core i7 Xeon E5-2620 CPU and 11GB Nvidia GeForce GTX 1080Ti GPU. Different hyperparameters are used to train the model, and finally the network was trained for 50 epochs with 100 training steps per epoch. Initially, the learning rate is set to 0.001 and ends at 0.0001. Stochastic gradient descent is selected as the optimizer with a momentum of 0.9.</p></sec>
<sec>
<title>Evaluation metrics</title>
<p>Five hundred images set aside for testing are used to evaluate the trained network. The trained model segments the LV and generates test image segmented binary masks. These segmented binary masks are then compared to the ground truth binary mask of test images. The Dice Similarity Coefficient (DSC) is used to assess model accuracy. The overlap-based method used to calculate the dice similarity index is represented Equation (1) (<xref ref-type="bibr" rid="B46">46</xref>). S<sub>GT</sub> in the equation represents the ground truth image, which includes the original LV size and boundary. The model&#x00027;s segmented mask is represented by the S<sub>Seg</sub>. The DSC is calculated by dividing the intersected regions of two masks by the total region of both masks. DSC has a range of [0 1], with 0 representing no similarity or non-overlapping region and 1 representing exact overlapping.</p>
<disp-formula id="E1"><label>(1)</label><mml:math id="M1"><mml:mtable class="eqnarray" columnalign="right center left"><mml:mtr><mml:mtd><mml:mi>D</mml:mi><mml:mi>S</mml:mi><mml:mi>C</mml:mi><mml:mo>=</mml:mo><mml:mtext>&#x000A0;</mml:mtext><mml:mfrac><mml:mrow><mml:mn>2</mml:mn><mml:mo>|</mml:mo><mml:msub><mml:mrow><mml:mi>S</mml:mi></mml:mrow><mml:mrow><mml:mi>G</mml:mi><mml:mi>T</mml:mi></mml:mrow></mml:msub><mml:mtext>&#x000A0;</mml:mtext><mml:mo>&#x02229;</mml:mo><mml:mtext>&#x000A0;</mml:mtext><mml:msub><mml:mrow><mml:mi>S</mml:mi></mml:mrow><mml:mrow><mml:mi>S</mml:mi><mml:mi>e</mml:mi><mml:mi>g</mml:mi></mml:mrow></mml:msub><mml:mo>|</mml:mo></mml:mrow><mml:mrow><mml:mo>|</mml:mo><mml:msub><mml:mrow><mml:mi>S</mml:mi></mml:mrow><mml:mrow><mml:mi>G</mml:mi><mml:mi>T</mml:mi></mml:mrow></mml:msub><mml:mo>|</mml:mo><mml:mtext>&#x000A0;</mml:mtext><mml:mo>&#x0002B;</mml:mo><mml:mtext>&#x000A0;</mml:mtext><mml:mo>|</mml:mo><mml:msub><mml:mrow><mml:mi>S</mml:mi></mml:mrow><mml:mrow><mml:mi>S</mml:mi><mml:mi>e</mml:mi><mml:mi>g</mml:mi></mml:mrow></mml:msub><mml:mo>|</mml:mo></mml:mrow></mml:mfrac></mml:mtd></mml:mtr></mml:mtable></mml:math></disp-formula>
<p>The Equation (2) denotes the Jaccard index (<xref ref-type="bibr" rid="B47">47</xref>) (also known as intersection over union or IoU). The Jaccard index penalizes over- and under-segmentation more than the DSC.</p>
<disp-formula id="E2"><label>(2)</label><mml:math id="M2"><mml:mtable class="eqnarray" columnalign="right center left"><mml:mtr><mml:mtd><mml:mi>J</mml:mi><mml:mi>a</mml:mi><mml:mi>c</mml:mi><mml:mi>c</mml:mi><mml:mi>a</mml:mi><mml:mi>r</mml:mi><mml:mi>d</mml:mi><mml:mo>=</mml:mo><mml:mtext>&#x000A0;</mml:mtext><mml:mfrac><mml:mrow><mml:msub><mml:mrow><mml:mi>S</mml:mi></mml:mrow><mml:mrow><mml:mi>G</mml:mi><mml:mi>T</mml:mi></mml:mrow></mml:msub><mml:mo>&#x02229;</mml:mo><mml:mtext>&#x000A0;</mml:mtext><mml:msub><mml:mrow><mml:mi>S</mml:mi></mml:mrow><mml:mrow><mml:mi>S</mml:mi><mml:mi>e</mml:mi><mml:mi>g</mml:mi></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mrow><mml:mi>S</mml:mi></mml:mrow><mml:mrow><mml:mi>G</mml:mi><mml:mi>T</mml:mi></mml:mrow></mml:msub><mml:mo>&#x0222A;</mml:mo><mml:mtext>&#x000A0;</mml:mtext><mml:msub><mml:mrow><mml:mi>S</mml:mi></mml:mrow><mml:mrow><mml:mi>S</mml:mi><mml:mi>e</mml:mi><mml:mi>g</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfrac></mml:mtd></mml:mtr></mml:mtable></mml:math></disp-formula>
<p>The segmentation performance of the models is also evaluated using pixel accuracy. It simply calculates the percentage of pixels that are correctly classified. It is typically calculated for each class individually as well as for all classes. Equation (3) is used to calculate the accuracy.</p>
<disp-formula id="E3"><label>(3)</label><mml:math id="M3"><mml:mtable class="eqnarray" columnalign="right center left"><mml:mtr><mml:mtd><mml:mi>P</mml:mi><mml:mi>i</mml:mi><mml:mi>x</mml:mi><mml:mi>e</mml:mi><mml:mi>l</mml:mi><mml:mtext>&#x000A0;</mml:mtext><mml:mi>A</mml:mi><mml:mi>c</mml:mi><mml:mi>c</mml:mi><mml:mi>u</mml:mi><mml:mi>r</mml:mi><mml:mi>a</mml:mi><mml:mi>c</mml:mi><mml:mi>y</mml:mi><mml:mo>=</mml:mo><mml:mtext>&#x000A0;</mml:mtext><mml:mfrac><mml:mrow><mml:mi>T</mml:mi><mml:mi>P</mml:mi><mml:mo>&#x0002B;</mml:mo><mml:mi>T</mml:mi><mml:mi>N</mml:mi></mml:mrow><mml:mrow><mml:mi>T</mml:mi><mml:mi>P</mml:mi><mml:mo>&#x0002B;</mml:mo><mml:mi>T</mml:mi><mml:mi>N</mml:mi><mml:mo>&#x0002B;</mml:mo><mml:mi>F</mml:mi><mml:mi>P</mml:mi><mml:mo>&#x0002B;</mml:mo><mml:mi>F</mml:mi><mml:mi>N</mml:mi></mml:mrow></mml:mfrac></mml:mtd></mml:mtr></mml:mtable></mml:math></disp-formula>
<p>where TP is True Positive which represents the correctly classified pixels of the segmented class. The incorrectly classified pixels of the segmented class are FP i.e., False Positive. Similarly, TN is a True negative background pixel correctly classified, and FN is a False Negative indicating the incorrectly classified pixels of the background.</p>
<p>Three other evaluation metrics; recall, precision, and specificity are also adopted to evaluate the segmented mask. Recall, also known as sensitivity or true positive rate, focuses on the true positive detection capabilities. Specificity, also called True Negative Rate (TNR), is the percentage of negative pixels (background) in the ground truth segmentation that are also negative pixels in the segmentation being tested. The recall, precision, and specificity are computed by the formulas presented in Equations (4), (5), and, (6) respectively.</p>
<disp-formula id="E4"><label>(4)</label><mml:math id="M4"><mml:mtable class="eqnarray" columnalign="right center left"><mml:mtr><mml:mtd><mml:mi>R</mml:mi><mml:mi>e</mml:mi><mml:mi>c</mml:mi><mml:mi>a</mml:mi><mml:mi>l</mml:mi><mml:mi>l</mml:mi><mml:mo>=</mml:mo><mml:mtext>&#x000A0;</mml:mtext><mml:mfrac><mml:mrow><mml:mi>T</mml:mi><mml:mi>P</mml:mi></mml:mrow><mml:mrow><mml:mi>T</mml:mi><mml:mi>P</mml:mi><mml:mo>&#x0002B;</mml:mo><mml:mi>F</mml:mi><mml:mi>N</mml:mi></mml:mrow></mml:mfrac></mml:mtd></mml:mtr></mml:mtable></mml:math></disp-formula>
<disp-formula id="E5"><label>(5)</label><mml:math id="M5"><mml:mtable class="eqnarray" columnalign="right center left"><mml:mtr><mml:mtd><mml:mi>P</mml:mi><mml:mi>r</mml:mi><mml:mi>e</mml:mi><mml:mi>c</mml:mi><mml:mi>i</mml:mi><mml:mi>s</mml:mi><mml:mi>i</mml:mi><mml:mi>o</mml:mi><mml:mi>n</mml:mi><mml:mo>=</mml:mo><mml:mtext>&#x000A0;</mml:mtext><mml:mfrac><mml:mrow><mml:mi>T</mml:mi><mml:mi>P</mml:mi></mml:mrow><mml:mrow><mml:mi>T</mml:mi><mml:mi>P</mml:mi><mml:mo>&#x0002B;</mml:mo><mml:mi>F</mml:mi><mml:mi>P</mml:mi></mml:mrow></mml:mfrac></mml:mtd></mml:mtr></mml:mtable></mml:math></disp-formula>
<disp-formula id="E6"><label>(6)</label><mml:math id="M6"><mml:mtable class="eqnarray" columnalign="right center left"><mml:mtr><mml:mtd><mml:mi>S</mml:mi><mml:mi>p</mml:mi><mml:mi>e</mml:mi><mml:mi>c</mml:mi><mml:mi>i</mml:mi><mml:mi>f</mml:mi><mml:mi>i</mml:mi><mml:mi>c</mml:mi><mml:mi>i</mml:mi><mml:mi>t</mml:mi><mml:mi>y</mml:mi><mml:mo>=</mml:mo><mml:mtext>&#x000A0;</mml:mtext><mml:mfrac><mml:mrow><mml:mi>T</mml:mi><mml:mi>N</mml:mi></mml:mrow><mml:mrow><mml:mi>T</mml:mi><mml:mi>N</mml:mi><mml:mo>&#x0002B;</mml:mo><mml:mi>F</mml:mi><mml:mi>P</mml:mi></mml:mrow></mml:mfrac></mml:mtd></mml:mtr></mml:mtable></mml:math></disp-formula></sec></sec>
<sec sec-type="results" id="s4">
<title>Results</title>
<p>The SegNet, FCN, and Mask R-CNN architectures are trained using 1,000 training images and the networks are evaluated using 500 test images. <xref ref-type="table" rid="T1">Table 1</xref> shows the average values of DSC, Jaccard index, pixel accuracy, recall, precision, and specificity of the three architectures.</p>
<table-wrap position="float" id="T1">
<label>Table 1</label>
<caption><p>Minimum, maximum, and mean values with a standard deviation of evaluation metrics for three models.</p></caption>
<table frame="hsides" rules="groups">
<thead><tr>
<th valign="top" align="left"><bold>CNN Model</bold></th>
<th valign="top" align="center" colspan="3" style="border-bottom: thin solid #000000;"><bold>DSC</bold></th>
<th valign="top" align="center" colspan="3" style="border-bottom: thin solid #000000;"><bold>Jaccard index</bold></th>
<th valign="top" align="center" colspan="3" style="border-bottom: thin solid #000000;"><bold>Accuracy</bold></th>
<th valign="top" align="center" colspan="3" style="border-bottom: thin solid #000000;"><bold>Recall</bold></th>
<th valign="top" align="center" colspan="3" style="border-bottom: thin solid #000000;"><bold>Precision</bold></th>
<th valign="top" align="center" colspan="3" style="border-bottom: thin solid #000000;"><bold>Specificity</bold></th>
</tr>
<tr>
<th/>
<th valign="top" align="center"><bold>min</bold></th>
<th valign="top" align="center"><bold>max</bold></th>
<th valign="top" align="center"><bold>Mean &#x000B1;std</bold></th>
<th valign="top" align="center"><bold>min</bold></th>
<th valign="top" align="center"><bold>max</bold></th>
<th valign="top" align="center"><bold>Mean &#x000B1;std</bold></th>
<th valign="top" align="center"><bold>min</bold></th>
<th valign="top" align="center"><bold>max</bold></th>
<th valign="top" align="center"><bold>Mean &#x000B1;std</bold></th>
<th valign="top" align="center"><bold>min</bold></th>
<th valign="top" align="center"><bold>max</bold></th>
<th valign="top" align="center"><bold>Mean &#x000B1;std</bold></th>
<th valign="top" align="center"><bold>min</bold></th>
<th valign="top" align="center"><bold>max</bold></th>
<th valign="top" align="center"><bold>Mean &#x000B1;std</bold></th>
<th valign="top" align="center"><bold>min</bold></th>
<th valign="top" align="center"><bold>max</bold></th>
<th valign="top" align="center"><bold>Mean &#x000B1;std</bold></th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">SegNet</td>
<td valign="top" align="center">0.6492</td>
<td valign="top" align="center">0.8884</td>
<td valign="top" align="center">0.7651 &#x000B1; 0.0401</td>
<td valign="top" align="center">0.4806</td>
<td valign="top" align="center">0.7992</td>
<td valign="top" align="center">0.6195 &#x000B1; 0.0453</td>
<td valign="top" align="center">0.7524</td>
<td valign="top" align="center">0.9286</td>
<td valign="top" align="center">0.8455 &#x000B1; 0.025</td>
<td valign="top" align="center">0.3261</td>
<td valign="top" align="center">0.7981</td>
<td valign="top" align="center">0.7486 &#x000B1; 0.301</td>
<td valign="top" align="center">0.4813</td>
<td valign="top" align="center">0.8351</td>
<td valign="top" align="center">0.6519 &#x000B1; 0.055</td>
<td valign="top" align="center">0.5824</td>
<td valign="top" align="center">0.8621</td>
<td valign="top" align="center">0.6891 &#x000B1; 0.045</td>
</tr>
<tr>
<td valign="top" align="left">FCN</td>
<td valign="top" align="center">0.7106</td>
<td valign="top" align="center">0.9279</td>
<td valign="top" align="center">0.8386 &#x000B1; 0.0342</td>
<td valign="top" align="center">0.5511</td>
<td valign="top" align="center">0.8654</td>
<td valign="top" align="center">0.7221 &#x000B1; 0.0412</td>
<td valign="top" align="center">0.8627</td>
<td valign="top" align="center">0.9705</td>
<td valign="top" align="center">0.9193 &#x000B1; 0.019</td>
<td valign="top" align="center">0.4568</td>
<td valign="top" align="center">0.9872</td>
<td valign="top" align="center">0.9649 &#x000B1; 0.174</td>
<td valign="top" align="center">0.6013</td>
<td valign="top" align="center">0.8041</td>
<td valign="top" align="center">0.7238 &#x000B1; 0.043</td>
<td valign="top" align="center">0.6871</td>
<td valign="top" align="center">0.8877</td>
<td valign="top" align="center">0.7891 &#x000B1; 0.044</td>
</tr>
<tr>
<td valign="top" align="left">Mask<break/> R-CNN</td>
<td valign="top" align="center">0.7567</td>
<td valign="top" align="center">0.9958</td>
<td valign="top" align="center">0.8831 &#x000B1; 0.0356</td>
<td valign="top" align="center">0.6086</td>
<td valign="top" align="center">0.9916</td>
<td valign="top" align="center">0.7907 &#x000B1; 0.0401</td>
<td valign="top" align="center">0.8903</td>
<td valign="top" align="center">0.9981</td>
<td valign="top" align="center">0.9457 &#x000B1; 0.018</td>
<td valign="top" align="center">0.509</td>
<td valign="top" align="center">0.9910</td>
<td valign="top" align="center">0.9681 &#x000B1; 0.216</td>
<td valign="top" align="center">0.6321</td>
<td valign="top" align="center">0.8182</td>
<td valign="top" align="center">0.7937 &#x000B1; 0.031</td>
<td valign="top" align="center">0.7056</td>
<td valign="top" align="center">0.9021</td>
<td valign="top" align="center">0.8157 &#x000B1; 0.033</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>The SegNet results in the lowest average DSC level (0.7651), Jaccard (0.6195), mean accuracy (0.8455), recall (0.7486), precision (0.6519), and Specificity (0.6891).</p>
<p><xref ref-type="fig" rid="F4">Figure 4</xref> depicts these findings pictorially. The second row shows the predicted mask output from SegNet, FCN, and Mask R-CNN, in that order. The SegNet architecture fails to accurately predict labels for both boundaries and within the region. FCN outperforms SegNet in predicting boundaries and inside regions. Compared to SegNet and FCN, the Mask R-CNN achieves better LV boundary and inside region segmentation.</p>
<fig id="F4" position="float">
<label>Figure 4</label>
<caption><p>The top row represents the original Ultrasound image and ground truth binary mask. The bottom row shows the segmented results of the three architectures.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fpubh-10-981019-g0004.tif"/>
</fig>
<p>The Mask R-CNN is chosen to investigate the impact of training data size on segmentation performance based on the results of 1,000 training images presented in <xref ref-type="table" rid="T1">Table 1</xref> and <xref ref-type="fig" rid="F4">Figure 4</xref>. The Mask R-CNN model is evaluated by gradually increasing the size of the training data. The trained model is evaluated for each dataset by measuring the evaluation metrics on 500 test images.</p>
<p><xref ref-type="fig" rid="F5">Figure 5</xref> shows the three random samples of the trained model using 2,000 images. Ground truth binary masks of test images are shown in the first column, segmented LV in the second column, and segmented binary mask is presented in the third column.</p>
<fig id="F5" position="float">
<label>Figure 5</label>
<caption><p>Ground truth binary mask, segmented LV, and corresponding segmented binary masks (Using 2,000 images).</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fpubh-10-981019-g0005.tif"/>
</fig>
<p>Similarly, <xref ref-type="fig" rid="F6">Figure 6</xref> shows the output of the trained model using 3,000 images. In comparison to <xref ref-type="fig" rid="F5">Figure 5</xref>, the results are improved with an average DSC of 0.8945 and a mean accuracy of 0.9581. <xref ref-type="fig" rid="F7">Figure 7</xref> shows the results of 4,000 training images. The model was eventually trained by increasing the training data to 5,000 images. The model&#x00027;s performance became saturated, and no significant improvement in evaluation metrics was observed. The obtained average DSC and mean accuracy values are 0.9228 and 0.9881, respectively.</p>
<fig id="F6" position="float">
<label>Figure 6</label>
<caption><p>Ground truth binary mask, segmented LV, and corresponding segmented binary masks (Using 3,000 images).</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fpubh-10-981019-g0006.tif"/>
</fig>
<fig id="F7" position="float">
<label>Figure 7</label>
<caption><p>Ground truth binary mask, segmented LV, and corresponding segmented binary masks (using 4,000 images).</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fpubh-10-981019-g0007.tif"/>
</fig>
<p>The performance of the Mask R-CNN is evaluated by gradually increasing the training data size. <xref ref-type="table" rid="T2">Table 2</xref> shows the model&#x00027;s average values for all six evaluation metrics for different training data sizes. As training data is one of the key parameters for the performance of deep learning, increasing the training data improves the average values of evaluation metrics. The results show that increasing the training data improves Mask R-CNN performance with better LV segmentation.</p>
<table-wrap position="float" id="T2">
<label>Table 2</label>
<caption><p>Mean with standard deviation values of evaluation metrics using different training data size.</p></caption>
<table frame="hsides" rules="groups">
<thead><tr>
<th valign="top" align="left"><bold>Training data (Number of images)</bold></th>
<th valign="top" align="center"><bold>DSC (Mean &#x000B1;std)</bold></th>
<th valign="top" align="center"><bold>Jaccard index (Mean &#x000B1;std)</bold></th>
<th valign="top" align="center"><bold>Accuracy (Mean &#x000B1;std)</bold></th>
<th valign="top" align="center"><bold>Recall (Mean &#x000B1;std)</bold></th>
<th valign="top" align="center"><bold>Precision (Mean &#x000B1;std)</bold></th>
<th valign="top" align="center"><bold>Specificity (Mean &#x000B1;std)</bold></th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">1,000</td>
<td valign="top" align="center">0.8831 &#x000B1; 0.0356</td>
<td valign="top" align="center">0.7907 &#x000B1; 0.0401</td>
<td valign="top" align="center">0.9457 &#x000B1; 0.018</td>
<td valign="top" align="center">0.9681 &#x000B1; 0.216</td>
<td valign="top" align="center">0.7937 &#x000B1; 0.055</td>
<td valign="top" align="center">0.8057 &#x000B1; 0.033</td>
</tr>
<tr>
<td valign="top" align="left">2,000</td>
<td valign="top" align="center">0.8945 &#x000B1; 0.0365</td>
<td valign="top" align="center">0.8091 &#x000B1; 0.0372</td>
<td valign="top" align="center">0.9581 &#x000B1; 0.018</td>
<td valign="top" align="center">0.9712 &#x000B1; 0.201</td>
<td valign="top" align="center">0.8398 &#x000B1; 0.052</td>
<td valign="top" align="center">0.8462 &#x000B1; 0.057</td>
</tr>
<tr>
<td valign="top" align="left">3,000</td>
<td valign="top" align="center">0.9071 &#x000B1; 0.0281</td>
<td valign="top" align="center">0.8299 &#x000B1; 0.0313</td>
<td valign="top" align="center">0.9703 &#x000B1; 0.016</td>
<td valign="top" align="center">0.9809 &#x000B1; 0.170</td>
<td valign="top" align="center">0.8730 &#x000B1; 0.056</td>
<td valign="top" align="center">0.899 &#x000B1; 0.041</td>
</tr>
<tr>
<td valign="top" align="left">4,000</td>
<td valign="top" align="center">0.9221 &#x000B1; 0.0237</td>
<td valign="top" align="center">0.8555 &#x000B1; 0.0294</td>
<td valign="top" align="center">0.9876 &#x000B1; 0.015</td>
<td valign="top" align="center">0.9902 &#x000B1; 0.165</td>
<td valign="top" align="center">0.9315 &#x000B1; 0.049</td>
<td valign="top" align="center">0.9658 &#x000B1; 0.040</td>
</tr>
<tr>
<td valign="top" align="left">5,000</td>
<td valign="top" align="center">0.9228 &#x000B1; 0.0233</td>
<td valign="top" align="center">0.8566 &#x000B1; 0.2899</td>
<td valign="top" align="center">0.9881 &#x000B1; 0.015</td>
<td valign="top" align="center">0.9903 &#x000B1; 0.163</td>
<td valign="top" align="center">0.9317 &#x000B1; 0.050</td>
<td valign="top" align="center">0.9660 &#x000B1; 0.042</td>
</tr>
</tbody>
</table>
</table-wrap></sec>
<sec sec-type="discussion" id="s5">
<title>Discussion</title>
<p>In the study of the comparison of three different segmentation models, the SegNet was the only one that was unable to segment the LV accurately and also could not correctly segment the LV inside the boundary, as shown in <xref ref-type="fig" rid="F4">Figure 4</xref>. Due to the small size of its classes and the lack of convolutional architecture, SegNet has achieved a DSC value of 0.7651, a Jaccard index of 0.6195, accuracy of 0.8455, recall 0.7486, precision 0.6519, and specificity of 0.6819. The result reflects the inability of SegNet in capturing the global context of objects. The FCN achieves superior LV segmentation within the area, resulting in DSC value of 0.8386, 0.7221 of Jaccard index, 0.9193 accuracy, 0.9646 recall, 0.7328 precision, and specificity 0.7891, which are considerably better than SegNet.</p>
<p>FCN extracts the features through downsampling and then restores the image features through upsampling. This technique improves the extraction of features. However, this sequence of downsampling and upsampling might compromise segmentation owing to the loss of image detail. Mask R-CNN has shown the ability to effectively segment LV due to its architecture (which first suggests the region containing the LV followed by applying the ROI Align module for precise localization, and then finally separating the LV from the ROI as the subsequent step by a convolutional network). This process improves the accuracy of segmentation.</p>
<p>The impact of the size of the training data set on the overall segmentation performance of the model was also investigated in this research. The Mask R-CNN model is used for this analysis since among the three models, it exhibited the highest values across all evaluation metrics. It is observable that there is a significant performance improvement when the data size is gradually raised from 1000 to 4000 images, as illustrated in the <xref ref-type="fig" rid="F8">Figure 8</xref>.</p>
<fig id="F8" position="float">
<label>Figure 8</label>
<caption><p>Average values of evaluation metrics for different data size used for training the Mask R-CNN model.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fpubh-10-981019-g0008.tif"/>
</fig>
<p>The values DSC, Jaccard, accuracy, sensitivity, recall, and specificity increases from 0.8831, 0.7907, 0.9457, 0.9681, 0.7937, 0.333, and 0.8157 to 0.9221, 0.8555, 0.9876, 0.9902, 0.9315, 0.9558 respectively. But the performance of the model trained with 4000 or more input images became consistent. This is depicted in <xref ref-type="fig" rid="F8">Figure 8</xref> as the graph of all evaluation metrics is almost horizontal when data is increased from 4,000 to 5,000 images. It is evident from these results that the amount of training data has a significant effect on the performance of the model. However, after a certain number of training data sets, the performance of the deep learning model becomes constant.</p></sec>
<sec sec-type="conclusions" id="s6">
<title>Conclusion</title>
<p>One of the most important aspects of diagnosing cardiac disease is LV segmentation. Precise segmentation of the LV impacts significantly on our understanding toward the normal anatomy of the heart, as well as our ability to distinguish the aberrant or diseased structure of the heart. This article compares the SegNet, FCN, and Mask R-CNN architectures in segmenting the LV from echocardiography images. All networks were trained using a self-collected apical four chamber view of the echocardiography dataset. After training the models on 1,000 images, the performance of three architectures is compared. The experimental results showed that the Mask R-CNN architecture surpassed the SegNet and FCN architectures with a DSC of 0.8831, Jaccard index of 0.7907, accuracy of 0.9457, a recall of 0.9681, precision of 0.7937, and specificity of 0.8157. This work also takes into account the influence of training data size on segmentation performance. Due to its superior performance among the three models, the Mask R-CNN model was chosen for analysis. Mask R-CNN was trained using 2,000, 3,000, 4,000, and 5,000 images, and its performance improved as the training data size increased. After 4,000 echocardiography images, the model&#x00027;s performance was saturated, and no significant changes were observed thereafter. The evaluation metrics values on the dataset consisting of 5,000 images did not demonstrate a significant improvement. In future work, this work will be extended to segment the endocardium and epicardium of the LV, aiming to contribute to measuring the end-diastolic volume, end-systolic volume, and ejection fraction.</p></sec>
<sec sec-type="data-availability" id="s7">
<title>Data availability statement</title>
<p>The original contributions presented in the study are included in the article/supplementary material, further inquiries can be directed to the corresponding authors.</p></sec>
<sec id="s8">
<title>Ethics statement</title>
<p>All the images are collected using protocol number RD5/04/15 approved by the Research Ethics Board of National Heart Institute, Kuala Lumpur, Malaysia.</p></sec>
<sec id="s9">
<title>Author contributions</title>
<p>All authors listed have made a substantial, direct, and intellectual contribution to the work and approved it for publication.</p></sec>
<sec sec-type="funding-information" id="s10">
<title>Funding</title>
<p>This work was supported in part by Fundamental Research Grant Scheme (FRGS), Ministry of Higher Education Malaysia, and Universiti Malaya under the Grant Number FRGS/1/2019/TK04/UM/01/2.</p></sec>
<sec sec-type="COI-statement" id="conf1">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p></sec>
<sec sec-type="disclaimer" id="s12">
<title>Publisher&#x00027;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
</body>
<back>
<ref-list>
<title>References</title>
<ref id="B1">
<label>1.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Roth</surname> <given-names>GA</given-names></name> <name><surname>Johnson</surname> <given-names>C</given-names></name> <name><surname>Abajobir</surname> <given-names>A</given-names></name> <name><surname>Abd-Allah</surname> <given-names>F</given-names></name> <name><surname>Abera</surname> <given-names>SF</given-names></name> <name><surname>Abyu</surname> <given-names>G</given-names></name> <etal/></person-group>. <article-title>Global, regional, and national burden of cardiovascular diseases for 10 causes, 1990 to 2015</article-title>. <source>J Am Coll Cardiol.</source> (<year>2017</year>) <volume>70</volume>:<fpage>1</fpage>&#x02013;<lpage>25</lpage>. <pub-id pub-id-type="doi">10.1016/j.jacc.2017.04.052</pub-id><pub-id pub-id-type="pmid">28527533</pub-id></citation></ref>
<ref id="B2">
<label>2.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Laslett</surname> <given-names>LJ</given-names></name> <name><surname>Alagona</surname> <given-names>P</given-names></name> <name><surname>Clark</surname> <given-names>BA</given-names></name> <name><surname>Drozda</surname> <given-names>JP</given-names></name> <name><surname>Saldivar</surname> <given-names>F</given-names></name> <name><surname>Wilson</surname> <given-names>SR</given-names></name> <etal/></person-group>. <article-title>The worldwide environment of cardiovascular disease : prevalence, diagnosis, therapy, and policy issues a report from the American college of cardiology</article-title>. <source>J Am Coll Cardiol.</source> (<year>2012</year>) <volume>60</volume>:<fpage>S1</fpage>&#x02013;<lpage>49</lpage>. <pub-id pub-id-type="doi">10.1016/j.jacc.2012.11.002</pub-id><pub-id pub-id-type="pmid">23257320</pub-id></citation></ref>
<ref id="B3">
<label>3.</label>
<citation citation-type="web"><source>Cardiovascular Diseases (CVDs)</source>. Available online at: <ext-link ext-link-type="uri" xlink:href="https://www.who.int/news-room/fact-sheets/detail/cardiovascular-diseases-(cvds)">https://www.who.int/news-room/fact-sheets/detail/cardiovascular-diseases-(cvds)</ext-link> (accessed May 18, 2020).</citation>
</ref>
<ref id="B4">
<label>4.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Liew</surname> <given-names>YM</given-names></name> <name><surname>McLaughlin</surname> <given-names>RA</given-names></name> <name><surname>Chan</surname> <given-names>BT</given-names></name> <name><surname>Abdul Aziz</surname> <given-names>YF</given-names></name> <name><surname>Chee</surname> <given-names>KH</given-names></name> <name><surname>Ung</surname> <given-names>NM</given-names></name> <etal/></person-group>. <article-title>Motion corrected LV quantification based on 3D modelling for improved functional assessment in cardiac MRI</article-title>. <source>Phys Med Biol</source>. (<year>2015</year>) <volume>60</volume>:<fpage>2715</fpage>&#x02013;<lpage>33</lpage>. <pub-id pub-id-type="doi">10.1088/0031-9155/60/7/2715</pub-id><pub-id pub-id-type="pmid">25768708</pub-id></citation></ref>
<ref id="B5">
<label>5.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Irshad</surname> <given-names>M</given-names></name> <name><surname>Sharif</surname> <given-names>M</given-names></name> <name><surname>Yasmin</surname> <given-names>M</given-names></name> <name><surname>Khan</surname> <given-names>A</given-names></name></person-group>. <article-title>A survey on left ventricle segmentation techniques in cardiac short axis MRI</article-title>. <source>Curr Med Imaging Rev.</source> (<year>2018</year>) <volume>14</volume>:<fpage>223</fpage>&#x02013;<lpage>37</lpage>. <pub-id pub-id-type="doi">10.2174/1573405613666170117124934</pub-id></citation>
</ref>
<ref id="B6">
<label>6.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Alfakih</surname> <given-names>K</given-names></name> <name><surname>Reid</surname> <given-names>S</given-names></name> <name><surname>Jones</surname> <given-names>T</given-names></name> <name><surname>Sivananthan</surname> <given-names>M</given-names></name></person-group>. <article-title>Assessment of ventricular function and mass by cardiac magnetic resonance imaging</article-title>. <source>Eur Radiol.</source> (<year>2004</year>) <volume>14</volume>:<fpage>1813</fpage>&#x02013;<lpage>22</lpage>. <pub-id pub-id-type="doi">10.1007/s00330-004-2387-0</pub-id><pub-id pub-id-type="pmid">15258823</pub-id></citation></ref>
<ref id="B7">
<label>7.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Khalil</surname> <given-names>A</given-names></name> <name><surname>Ng</surname> <given-names>SC</given-names></name> <name><surname>Liew</surname> <given-names>YM</given-names></name> <name><surname>Lai</surname> <given-names>KW</given-names></name></person-group>. <article-title>An overview on image registration techniques for cardiac diagnosis and treatment</article-title>. <source>Cardiol Res Pract.</source> (<year>2018</year>) <volume>2018</volume>:<fpage>1437125</fpage>. <pub-id pub-id-type="doi">10.1155/2018/1437125</pub-id><pub-id pub-id-type="pmid">30159169</pub-id></citation></ref>
<ref id="B8">
<label>8.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Huang</surname> <given-names>X</given-names></name> <name><surname>Dione</surname> <given-names>DP</given-names></name> <name><surname>Compas</surname> <given-names>CB</given-names></name> <name><surname>Papademetris</surname> <given-names>X</given-names></name> <name><surname>Lin</surname> <given-names>BA</given-names></name> <name><surname>Bregasi</surname> <given-names>A</given-names></name> <etal/></person-group>. <article-title>Contour tracking in echocardiographic sequences via sparse representation and dictionary learning</article-title>. <source>Med Image Anal.</source> (<year>2014</year>) <volume>18</volume>:<fpage>253</fpage>&#x02013;<lpage>71</lpage>. <pub-id pub-id-type="doi">10.1016/j.media.2013.10.012</pub-id><pub-id pub-id-type="pmid">24292554</pub-id></citation></ref>
<ref id="B9">
<label>9.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Anderson</surname> <given-names>JL</given-names></name></person-group>. <article-title>2013 ACCF/AHA guideline for the management of ST-elevation myocardial infarction: executive summary: a report of the American college of cardiology foundation/American heart association task force on practice guidelines</article-title>. <source>Circulation.</source> (<year>2013</year>) <volume>127</volume>:<fpage>529</fpage>&#x02013;<lpage>55</lpage>. <pub-id pub-id-type="doi">10.1161/CIR.0b013e3182742c84</pub-id><pub-id pub-id-type="pmid">23299937</pub-id></citation></ref>
<ref id="B10">
<label>10.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sonka</surname> <given-names>M</given-names></name> <name><surname>Liang</surname> <given-names>W</given-names></name> <name><surname>Kanani</surname> <given-names>P</given-names></name> <name><surname>Allan</surname> <given-names>J</given-names></name> <name><surname>DeJong</surname> <given-names>S</given-names></name> <name><surname>Kerber</surname> <given-names>R</given-names></name> <etal/></person-group>. <article-title>Intracardiac echocardiography: computerized detection of left ventricular borders</article-title>. <source>Int J Card Imaging.</source> (<year>1998</year>) <volume>14</volume>:<fpage>397</fpage>&#x02013;<lpage>411</lpage>. <pub-id pub-id-type="doi">10.1023/A:1006114907352</pub-id><pub-id pub-id-type="pmid">10453395</pub-id></citation></ref>
<ref id="B11">
<label>11.</label>
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Goceri</surname> <given-names>N</given-names></name> <name><surname>Goceri</surname> <given-names>E</given-names></name></person-group>. <article-title>A Neural Network Based Kidney Segmentation from MR Images</article-title>. In: <source>2015 IEEE 14th International Conference on Machine Learning and Applications (ICMLA)</source>. <publisher-loc>Miami, FL</publisher-loc>: <publisher-name>IEEE</publisher-name> (<year>2015</year>). p. <fpage>1195</fpage>&#x02013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1109/ICMLA.2015.229</pub-id></citation>
</ref>
<ref id="B12">
<label>12.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Goceri</surname> <given-names>E</given-names></name></person-group>. <source>A Comparative Evaluation for Liver Segmentation From Spir Images and a Novel Level Set Method Using Signed Pressure Force Function</source> (<year>2013</year>).</citation>
</ref>
<ref id="B13">
<label>13.</label>
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Goceri</surname> <given-names>E</given-names></name> <name><surname>Unlu</surname> <given-names>MZ</given-names></name> <name><surname>Guzelis</surname> <given-names>C</given-names></name> <name><surname>Dicle</surname> <given-names>O</given-names></name></person-group>. <article-title>An automatic level set based liver segmentation from MRI data sets</article-title>. In: <source>2012 3rd International Conference on Image Processing Theory, Tools and Applications (IPTA)</source>. <publisher-loc>Istanbul</publisher-loc>: <publisher-name>IEEE</publisher-name> (<year>2012</year>). p. <fpage>192</fpage>&#x02013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1109/IPTA.2012.6469551</pub-id></citation>
</ref>
<ref id="B14">
<label>14.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dziri</surname> <given-names>H</given-names></name> <name><surname>Cherni</surname> <given-names>MA</given-names></name> <name><surname>Ben-Sellem</surname> <given-names>D</given-names></name></person-group>. <article-title>New hybrid method for left ventricular ejection fraction assessment from radionuclide ventriculography images</article-title>. <source>Curr Med Imaging Former Curr Med Imaging Rev.</source> (<year>2021</year>) <volume>17</volume>:<fpage>623</fpage>&#x02013;<lpage>33</lpage>. <pub-id pub-id-type="doi">10.2174/1573405616666201118122509</pub-id><pub-id pub-id-type="pmid">33213328</pub-id></citation></ref>
<ref id="B15">
<label>15.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Spencer</surname> <given-names>KT</given-names></name> <name><surname>Bednarz</surname> <given-names>J</given-names></name> <name><surname>Mor-Avi</surname> <given-names>V</given-names></name> <name><surname>DeCara</surname> <given-names>J</given-names></name> <name><surname>Lang</surname> <given-names>RM</given-names></name></person-group>. <article-title>Automated endocardial border detection and evaluation of left ventricular function from contrast-enhanced images using modified acoustic quantification</article-title>. <source>J Am Soc Echocardiogr.</source> (<year>2002</year>) <volume>15</volume>:<fpage>777</fpage>&#x02013;<lpage>81</lpage>. <pub-id pub-id-type="doi">10.1067/mje.2002.120505</pub-id><pub-id pub-id-type="pmid">12174346</pub-id></citation></ref>
<ref id="B16">
<label>16.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Katouzian</surname> <given-names>A</given-names></name> <name><surname>Angelini</surname> <given-names>ED</given-names></name> <name><surname>Carlier</surname> <given-names>SG</given-names></name> <name><surname>Suri</surname> <given-names>JS</given-names></name> <name><surname>Navab</surname> <given-names>N</given-names></name> <name><surname>Laine</surname> <given-names>AF</given-names></name> <etal/></person-group>. <article-title>state-of-the-art review on segmentation algorithms in intravascular ultrasound (IVUS) images</article-title>. <source>IEEE Trans Inf Technol Biomed.</source> (<year>2012</year>) <volume>16</volume>:<fpage>823</fpage>&#x02013;<lpage>34</lpage>. <pub-id pub-id-type="doi">10.1109/TITB.2012.2189408</pub-id><pub-id pub-id-type="pmid">22389156</pub-id></citation></ref>
<ref id="B17">
<label>17.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>McInerney</surname> <given-names>T</given-names></name> <name><surname>Terzopoulos</surname> <given-names>D</given-names></name></person-group>. <article-title>Deformable models in medical image analysis: a survey</article-title>. <source>Med Image Anal.</source> (<year>1996</year>) <volume>1</volume>:<fpage>91</fpage>&#x02013;<lpage>108</lpage>. <pub-id pub-id-type="doi">10.1016/S1361-8415(96)80007-7</pub-id><pub-id pub-id-type="pmid">9873923</pub-id></citation></ref>
<ref id="B18">
<label>18.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhu</surname> <given-names>Y</given-names></name> <name><surname>Papademetris</surname> <given-names>X</given-names></name> <name><surname>Sinusas</surname> <given-names>AJ</given-names></name> <name><surname>Duncan</surname> <given-names>JS</given-names></name></person-group>. <article-title>A coupled deformable model for tracking myocardial borders from real-time echocardiography using an incompressibility constraint</article-title>. <source>Med Image Anal.</source> (<year>2010</year>) <volume>14</volume>:<fpage>429</fpage>&#x02013;<lpage>48</lpage>. <pub-id pub-id-type="doi">10.1016/j.media.2010.02.005</pub-id><pub-id pub-id-type="pmid">20350833</pub-id></citation></ref>
<ref id="B19">
<label>19.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jahanzad</surname> <given-names>Z</given-names></name> <name><surname>Liew</surname> <given-names>YM</given-names></name> <name><surname>Bilgen</surname> <given-names>M</given-names></name> <name><surname>McLaughlin</surname> <given-names>RA</given-names></name> <name><surname>Leong</surname> <given-names>CO</given-names></name> <name><surname>Chee</surname> <given-names>KH</given-names></name> <etal/></person-group>. <article-title>Regional assessment of LV wall in infarcted heart using tagged MRI and cardiac modelling</article-title>. <source>Phys Med Biol.</source> (<year>2015</year>) <volume>60</volume>:<fpage>4015</fpage>&#x02013;<lpage>31</lpage>. <pub-id pub-id-type="doi">10.1088/0031-9155/60/10/4015</pub-id><pub-id pub-id-type="pmid">25919317</pub-id></citation></ref>
<ref id="B20">
<label>20.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>de Alexandria</surname> <given-names>AR</given-names></name> <name><surname>Cortez</surname> <given-names>PC</given-names></name> <name><surname>Bessa</surname> <given-names>JA</given-names></name> <name><surname>de Alexandria</surname> <given-names>AR</given-names></name> <name><surname>de Abreu</surname> <given-names>JS</given-names></name> <name><surname>da Silva F&#x000E9;lix</surname> <given-names>JH</given-names></name> <etal/></person-group>. <article-title>pSnakes: a new radial active contour model and its application in the segmentation of the left ventricle from echocardiographic images</article-title>. <source>Comput Methods Programs Biomed.</source> (<year>2014</year>) <volume>116</volume>:<fpage>260</fpage>&#x02013;<lpage>73</lpage>. <pub-id pub-id-type="doi">10.1016/j.cmpb.2014.05.009</pub-id><pub-id pub-id-type="pmid">24957548</pub-id></citation></ref>
<ref id="B21">
<label>21.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhang</surname> <given-names>S</given-names></name> <name><surname>Zhan</surname> <given-names>Y</given-names></name> <name><surname>Metaxas</surname> <given-names>DN</given-names></name></person-group>. <article-title>Deformable segmentation via sparse representation and dictionary learning</article-title>. <source>Med Image Anal.</source> (<year>2012</year>) <volume>16</volume>:<fpage>1385</fpage>&#x02013;<lpage>96</lpage>. <pub-id pub-id-type="doi">10.1016/j.media.2012.07.007</pub-id><pub-id pub-id-type="pmid">22959839</pub-id></citation></ref>
<ref id="B22">
<label>22.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dietenbeck</surname> <given-names>T</given-names></name> <name><surname>Alessandrini</surname> <given-names>M</given-names></name> <name><surname>Barbosa</surname> <given-names>D</given-names></name> <name><surname>D&#x00027;hooge</surname> <given-names>J</given-names></name> <name><surname>Friboulet</surname> <given-names>D</given-names></name> <name><surname>Bernard</surname> <given-names>O</given-names></name></person-group>. <article-title>Detection of the whole myocardium in 2D-echocardiography for multiple orientations using a geometrically constrained level-set</article-title>. <source>Med Image Anal.</source> (<year>2012</year>) <volume>16</volume>:<fpage>386</fpage>&#x02013;<lpage>401</lpage>. <pub-id pub-id-type="doi">10.1016/j.media.2011.10.003</pub-id><pub-id pub-id-type="pmid">22119489</pub-id></citation></ref>
<ref id="B23">
<label>23.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dietenbeck</surname> <given-names>T</given-names></name> <name><surname>Barbosa</surname> <given-names>D</given-names></name> <name><surname>Alessandrini</surname> <given-names>M</given-names></name> <name><surname>Jasaityte</surname> <given-names>R</given-names></name> <name><surname>Robesyn</surname> <given-names>V</given-names></name></person-group>. <article-title>D&#x00027;hooge J, et al. Whole myocardium tracking in 2D-echocardiography in multiple orientations using a motion constrained level-set</article-title>. <source>Med Image Anal.</source> (<year>2014</year>) <volume>18</volume>:<fpage>500</fpage>&#x02013;<lpage>14</lpage>. <pub-id pub-id-type="doi">10.1016/j.media.2014.01.005</pub-id><pub-id pub-id-type="pmid">24561989</pub-id></citation></ref>
<ref id="B24">
<label>24.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mitchell</surname> <given-names>SC</given-names></name> <name><surname>Bosch</surname> <given-names>JG</given-names></name> <name><surname>Lelieveldt</surname> <given-names>BPF</given-names></name> <name><surname>Van der Geest</surname> <given-names>RJ</given-names></name> <name><surname>Reiber</surname> <given-names>JHC</given-names></name> <name><surname>Sonka</surname> <given-names>M</given-names></name></person-group>. <article-title>3-D active appearance models: segmentation of cardiac MR and ultrasound images</article-title>. <source>IEEE Trans Med Imaging.</source> (<year>2002</year>) <volume>21</volume>:<fpage>1167</fpage>&#x02013;<lpage>78</lpage>. <pub-id pub-id-type="doi">10.1109/TMI.2002.804425</pub-id><pub-id pub-id-type="pmid">12564884</pub-id></citation></ref>
<ref id="B25">
<label>25.</label>
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Van Stralen</surname> <given-names>M</given-names></name> <name><surname>Leung</surname> <given-names>KYE</given-names></name> <name><surname>Voormolen</surname> <given-names>MM</given-names></name> <name><surname>De Jong</surname> <given-names>N</given-names></name> <name><surname>Van Der Steen</surname> <given-names>AFW</given-names></name> <name><surname>Reiber</surname> <given-names>JHC</given-names></name> <etal/></person-group>. <article-title>Automatic segmentation of the left ventricle in 3D echocardiography using active appearance models</article-title>. In: <source>Proceedings of IEEE Ultrasonics Symposium</source>. <publisher-loc>New York, NY</publisher-loc>: <publisher-name>IEEE</publisher-name> (<year>2007</year>). p. <fpage>1480</fpage>&#x02013;<lpage>3</lpage>. <pub-id pub-id-type="doi">10.1109/ULTSYM.2007.372</pub-id></citation>
</ref>
<ref id="B26">
<label>26.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Carminati</surname> <given-names>MC</given-names></name> <name><surname>Piazzese</surname> <given-names>C</given-names></name> <name><surname>Pepi</surname> <given-names>M</given-names></name> <name><surname>Tamborini</surname> <given-names>G</given-names></name> <name><surname>Gripari</surname> <given-names>P</given-names></name> <name><surname>Pontone</surname> <given-names>G</given-names></name> <etal/></person-group>. <article-title>A statistical shape model of the left ventricle from real-time 3D echocardiography and its application to myocardial segmentation of cardiac magnetic resonance images</article-title>. <source>Comput Biol Med</source>. (<year>2018</year>) <volume>96</volume>:<fpage>241</fpage>&#x02013;<lpage>51</lpage>. <pub-id pub-id-type="doi">10.1016/j.compbiomed.2018.03.013</pub-id><pub-id pub-id-type="pmid">29653353</pub-id></citation></ref>
<ref id="B27">
<label>27.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yang</surname> <given-names>L</given-names></name> <name><surname>Georgescu</surname> <given-names>B</given-names></name> <name><surname>Zheng</surname> <given-names>Y</given-names></name> <name><surname>Wang</surname> <given-names>Y</given-names></name> <name><surname>Meer</surname> <given-names>P</given-names></name> <name><surname>Comaniciu</surname> <given-names>D</given-names></name></person-group>. <article-title>Prediction based collaborative trackers (PCT): a robust and accurate approach toward 3d medical object tracking</article-title>. <source>IEEE Trans Med Imaging.</source> (<year>2011</year>) <volume>30</volume>:<fpage>1921</fpage>&#x02013;<lpage>32</lpage>. <pub-id pub-id-type="doi">10.1109/TMI.2011.2158440</pub-id><pub-id pub-id-type="pmid">21642040</pub-id></citation></ref>
<ref id="B28">
<label>28.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Stebbing R</surname> <given-names>V</given-names></name> <name><surname>Noble</surname> <given-names>JA</given-names></name></person-group>. <article-title>Delineating anatomical boundaries using the boundary fragment model</article-title>. <source>Med Image Anal.</source> (<year>2013</year>) <volume>17</volume>:<fpage>1123</fpage>&#x02013;<lpage>36</lpage>. <pub-id pub-id-type="doi">10.1016/j.media.2013.07.001</pub-id><pub-id pub-id-type="pmid">23941869</pub-id></citation></ref>
<ref id="B29">
<label>29.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lempitsky</surname> <given-names>V</given-names></name> <name><surname>Verhoek</surname> <given-names>M</given-names></name> <name><surname>Noble</surname> <given-names>JA</given-names></name> <name><surname>Blake</surname> <given-names>A</given-names></name></person-group>. <article-title>Random forest classification for automatic delineation of myocardium in real-time 3D echocardiography</article-title>. <source>Comput Sci.</source> (<year>2009</year>) <volume>5528</volume>:<fpage>447</fpage>&#x02013;<lpage>56</lpage>. <pub-id pub-id-type="doi">10.1007/978-3-642-01932-6_48</pub-id></citation>
</ref>
<ref id="B30">
<label>30.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Milletari</surname> <given-names>F</given-names></name> <name><surname>Yigitsoy</surname> <given-names>M</given-names></name> <name><surname>Navab</surname> <given-names>N</given-names></name></person-group>. <article-title>Left ventricle segmentation in cardiac ultrasound using hough-forests with implicit shape and appearance priors</article-title>. <source>Midas J</source>. (<year>2014</year>) <fpage>49</fpage>&#x02013;<lpage>56</lpage>. <pub-id pub-id-type="doi">10.54294/y9qm6j</pub-id></citation>
</ref>
<ref id="B31">
<label>31.</label>
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Domingos</surname> <given-names>JS</given-names></name> <name><surname>Stebbing</surname> <given-names>R V</given-names></name> <name><surname>Leeson</surname> <given-names>P</given-names></name> <name><surname>Noble</surname> <given-names>JA</given-names></name></person-group>. <source>Structured Random Forests for Myocardium Delineation in 3D Echocardiography.</source> (<year>2014</year>). p. <fpage>215</fpage>&#x02013;<lpage>22</lpage>. <pub-id pub-id-type="doi">10.1007/978-3-319-10581-9_27</pub-id></citation>
</ref>
<ref id="B32">
<label>32.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Keraudren</surname> <given-names>K</given-names></name> <name><surname>Oktay</surname> <given-names>O</given-names></name> <name><surname>Shi</surname> <given-names>W</given-names></name> <name><surname>Hajnal J</surname> <given-names>V</given-names></name> <name><surname>Rueckert</surname> <given-names>D</given-names></name></person-group>. <article-title>Endocardial 3D ultrasound segmentation using autocontext random forests</article-title>. <source>Midas J</source>. (<year>2014</year>) <fpage>41</fpage>&#x02013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.54294/wu2mi1</pub-id></citation>
</ref>
<ref id="B33">
<label>33.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chen</surname> <given-names>L-C</given-names></name> <name><surname>Papandreou</surname> <given-names>G</given-names></name> <name><surname>Kokkinos</surname> <given-names>I</given-names></name> <name><surname>Murphy</surname> <given-names>K</given-names></name> <name><surname>Yuille</surname> <given-names>AL</given-names></name></person-group>. <article-title>DeepLab: semantic image segmentation with deep convolutional nets, atrous convolution, and fully connected CRFs</article-title>. <source>IEEE Trans Pattern Anal Mach Intell.</source> (<year>2018</year>) <volume>40</volume>:<fpage>834</fpage>&#x02013;<lpage>48</lpage>. <pub-id pub-id-type="doi">10.1109/TPAMI.2017.2699184</pub-id><pub-id pub-id-type="pmid">28463186</pub-id></citation></ref>
<ref id="B34">
<label>34.</label>
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Milletari</surname> <given-names>F</given-names></name> <name><surname>Navab</surname> <given-names>N</given-names></name> <name><surname>Ahmadi</surname> <given-names>SA</given-names></name></person-group>. <article-title>V-Net: Fully convolutional neural networks for volumetric medical image segmentation</article-title>. In: <source>Proceedings of 2016 4th International Conference 3D Vision, 3DV 2016</source>. <publisher-loc>Standford, CA</publisher-loc> (<year>2016</year>). p. <fpage>565</fpage>&#x02013;<lpage>71</lpage>. <pub-id pub-id-type="doi">10.1109/3DV.2016.79</pub-id></citation>
</ref>
<ref id="B35">
<label>35.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Badrinarayanan</surname> <given-names>V</given-names></name> <name><surname>Kendall</surname> <given-names>A</given-names></name> <name><surname>Cipolla</surname> <given-names>R</given-names></name></person-group>. <article-title>SegNet: A deep convolutional encoder-decoder architecture for image segmentation</article-title>. <source>IEEE Trans Pattern Anal Mach Intell</source>. (<year>2017</year>) <volume>39</volume>:<fpage>2481</fpage>&#x02013;<lpage>95</lpage>. <pub-id pub-id-type="doi">10.1109/TPAMI.2016.2644615</pub-id><pub-id pub-id-type="pmid">28060704</pub-id></citation></ref>
<ref id="B36">
<label>36.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dong</surname> <given-names>S</given-names></name> <name><surname>Luo</surname> <given-names>G</given-names></name> <name><surname>Sun</surname> <given-names>G</given-names></name> <name><surname>Wang</surname> <given-names>K</given-names></name> <name><surname>Zhang</surname> <given-names>H</given-names></name></person-group>. <source>A Left Ventricular Segmentation Method on 3D Echocardiography using Deep Learning and Snake</source>. (<year>2016</year>). p. <fpage>473</fpage>&#x02013;<lpage>6</lpage>. <pub-id pub-id-type="doi">10.22489/CinC.2016.136-409</pub-id></citation>
</ref>
<ref id="B37">
<label>37.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dong</surname> <given-names>S</given-names></name> <name><surname>Luo</surname> <given-names>G</given-names></name> <name><surname>Wang</surname> <given-names>K</given-names></name> <name><surname>Cao</surname> <given-names>S</given-names></name> <name><surname>Li</surname> <given-names>Q</given-names></name> <name><surname>Zhang</surname> <given-names>H</given-names></name></person-group>. <article-title>A combined fully convolutional networks and deformable model for automatic left ventricle segmentation based on 3D echocardiography</article-title>. <source>Biomed Res Int.</source> (<year>2018</year>) <volume>2018</volume>:<fpage>5682365</fpage>. <pub-id pub-id-type="doi">10.1155/2018/5682365</pub-id><pub-id pub-id-type="pmid">30276211</pub-id></citation></ref>
<ref id="B38">
<label>38.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Koo</surname> <given-names>HJ</given-names></name> <name><surname>Lee</surname> <given-names>JG</given-names></name> <name><surname>Ko</surname> <given-names>JY</given-names></name> <name><surname>Lee</surname> <given-names>G</given-names></name> <name><surname>Kang</surname> <given-names>JW</given-names></name> <name><surname>Kim</surname> <given-names>YH</given-names></name> <etal/></person-group>. <article-title>Automated segmentation of left ventricular myocardium on cardiac computed tomography using deep learning</article-title>. <source>Korean J Radiol.</source> (<year>2020</year>) <volume>21</volume>:<fpage>660</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.3348/kjr.2019.0378</pub-id><pub-id pub-id-type="pmid">32410405</pub-id></citation></ref>
<ref id="B39">
<label>39.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zabihollahy</surname> <given-names>F</given-names></name> <name><surname>Rajchl</surname> <given-names>M</given-names></name> <name><surname>White</surname> <given-names>JA</given-names></name> <name><surname>Ukwatta</surname> <given-names>E</given-names></name></person-group>. <article-title>Fully automated segmentation of left ventricular scar from 3D late gadolinium enhancement magnetic resonance imaging using a cascaded multi-planar U-Net (CMPU-Net)</article-title>. <source>Med Phys.</source> (<year>2020</year>) <volume>47</volume>:<fpage>1645</fpage>&#x02013;<lpage>55</lpage>. <pub-id pub-id-type="doi">10.1002/mp.14022</pub-id><pub-id pub-id-type="pmid">31955415</pub-id></citation></ref>
<ref id="B40">
<label>40.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yang</surname> <given-names>X</given-names></name> <name><surname>Tjio</surname> <given-names>G</given-names></name> <name><surname>Yang</surname> <given-names>F</given-names></name> <name><surname>DIng</surname> <given-names>J</given-names></name> <name><surname>Kumar</surname> <given-names>S</given-names></name> <name><surname>Leng</surname> <given-names>S</given-names></name> <etal/></person-group>. <article-title>A multi-channel deep learning approach for segmentation of the left ventricular endocardium from cardiac images</article-title>. <source>Proc Annu Int Conf IEEE Eng Med Biol Soc</source>. (<year>2019</year>) <volume>2019</volume>:<fpage>4016</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1109/EMBC.2019.8856833</pub-id><pub-id pub-id-type="pmid">31946752</pub-id></citation></ref>
<ref id="B41">
<label>41.</label>
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Smistad</surname> <given-names>E</given-names></name> <name><surname>Ostvik</surname> <given-names>A</given-names></name> <name><surname>Haugen</surname> <given-names>BO</given-names></name> <name><surname>Lovstakken</surname> <given-names>L</given-names></name></person-group>. <article-title>2D left ventricle segmentation using deep learning</article-title>. In: <source>IEEE International Ultrasonic Symposium</source>. <publisher-loc>Washington, DC</publisher-loc>: <publisher-name>IEEE</publisher-name> (<year>2017</year>). p. <fpage>4</fpage>&#x02013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1109/ULTSYM.2017.8092812</pub-id></citation>
</ref>
<ref id="B42">
<label>42.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Oktay</surname> <given-names>O</given-names></name> <name><surname>Ferrante</surname> <given-names>E</given-names></name> <name><surname>Kamnitsas</surname> <given-names>K</given-names></name> <name><surname>Heinrich</surname> <given-names>M</given-names></name> <name><surname>Bai</surname> <given-names>W</given-names></name> <name><surname>Caballero</surname> <given-names>J</given-names></name> <etal/></person-group>. <article-title>Anatomically constrained neural networks (ACNNs): application to cardiac image enhancement and segmentation</article-title>. <source>IEEE Trans Med Imaging.</source> (<year>2018</year>) <volume>37</volume>:<fpage>384</fpage>&#x02013;<lpage>95</lpage>. <pub-id pub-id-type="doi">10.1109/TMI.2017.2743464</pub-id><pub-id pub-id-type="pmid">28961105</pub-id></citation></ref>
<ref id="B43">
<label>43.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Leclerc</surname> <given-names>S</given-names></name> <name><surname>Smistad</surname> <given-names>E</given-names></name> <name><surname>Grenier</surname> <given-names>T</given-names></name> <name><surname>Lartizien</surname> <given-names>C</given-names></name> <name><surname>Ostvik</surname> <given-names>A</given-names></name> <name><surname>Espinosa</surname> <given-names>F</given-names></name> <etal/></person-group>. <article-title>Deep learning applied to multi-structure segmentation in 2d echocardiography: a preliminary investigation of the required database size</article-title>. <source>IEEE Int Ultrason Symp.</source> (<year>2018</year>) <volume>2018</volume>:<fpage>1</fpage>&#x02013;<lpage>4</lpage>. <pub-id pub-id-type="doi">10.1109/ULTSYM.2018.8580136</pub-id></citation>
</ref>
<ref id="B44">
<label>44.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Leclerc</surname> <given-names>S</given-names></name> <name><surname>Smistad</surname> <given-names>E</given-names></name> <name><surname>Pedrosa</surname> <given-names>J</given-names></name> <name><surname>Ostvik</surname> <given-names>A</given-names></name> <name><surname>Cervenansky</surname> <given-names>F</given-names></name> <name><surname>Espinosa</surname> <given-names>F</given-names></name> <etal/></person-group>. <article-title>Deep learning for segmentation using an open large-scale dataset in 2D echocardiography</article-title>. <source>IEEE Trans Med Imaging.</source> (<year>2019</year>) <volume>38</volume>:<fpage>2198</fpage>&#x02013;<lpage>210</lpage>. <pub-id pub-id-type="doi">10.1109/TMI.2019.2900516</pub-id><pub-id pub-id-type="pmid">30802851</pub-id></citation></ref>
<ref id="B45">
<label>45.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Shelhamer</surname> <given-names>E</given-names></name> <name><surname>Long</surname> <given-names>J</given-names></name> <name><surname>Darrell</surname> <given-names>T</given-names></name></person-group>. <article-title>Fully convolutional networks for semantic segmentation</article-title>. <source>IEEE Trans Pattern Anal Mach Intell.</source> (<year>2017</year>) <volume>39</volume>:<fpage>640</fpage>&#x02013;<lpage>51</lpage>. <pub-id pub-id-type="doi">10.1109/TPAMI.2016.2572683</pub-id><pub-id pub-id-type="pmid">27244717</pub-id></citation></ref>
<ref id="B46">
<label>46.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Khalil</surname> <given-names>A</given-names></name> <name><surname>Faisal</surname> <given-names>A</given-names></name> <name><surname>Lai</surname> <given-names>KW</given-names></name> <name><surname>Ng</surname> <given-names>SC</given-names></name> <name><surname>Liew</surname> <given-names>YM</given-names></name></person-group>. <article-title>2D to 3D fusion of echocardiography and cardiac CT for TAVR and TAVI image guidance</article-title>. <source>Med Biol Eng Comput.</source> (<year>2017</year>) <volume>55</volume>:<fpage>1317</fpage>&#x02013;<lpage>26</lpage>. <pub-id pub-id-type="doi">10.1007/s11517-016-1594-6</pub-id><pub-id pub-id-type="pmid">27830464</pub-id></citation></ref>
<ref id="B47">
<label>47.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Taha</surname> <given-names>A</given-names></name> <name><surname>Hanbury</surname> <given-names>A</given-names></name></person-group>. <article-title>Metrics for evaluating 3D medical image segmentation: Analysis, selection, and tool</article-title>. <source>BMC Med Imaging.</source> (<year>2015</year>) <volume>15</volume>:<fpage>29</fpage>. <pub-id pub-id-type="doi">10.1186/s12880-015-0068-x</pub-id><pub-id pub-id-type="pmid">26263899</pub-id></citation></ref>
</ref-list> 
</back>
</article> 