<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="review-article">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Public Health</journal-id>
<journal-title>Frontiers in Public Health</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Public Health</abbrev-journal-title>
<issn pub-type="epub">2296-2565</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fpubh.2021.638082</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Public Health</subject>
<subj-group>
<subject>Review</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Perchloroethylene and Dry Cleaning: It&#x00027;s Time to Move the Industry to Safer Alternatives</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name><surname>Ceballos</surname> <given-names>Diana M.</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="author-notes" rid="fn002"><sup>&#x02020;</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/1159096/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Fellows</surname> <given-names>Katie M.</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Evans</surname> <given-names>Ashley E.</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Janulewicz</surname> <given-names>Patricia A.</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Lee</surname> <given-names>Eun Gyung</given-names></name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/668617/overview"/>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name><surname>Whittaker</surname> <given-names>Stephen G.</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="corresp" rid="c001"><sup>&#x0002A;</sup></xref>
<xref ref-type="author-notes" rid="fn002"><sup>&#x02020;</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/1199968/overview"/>
</contrib>
</contrib-group>
<aff id="aff1"><sup>1</sup><institution>Department of Environmental Health, Boston University School of Public Health</institution>, <addr-line>Boston, MA</addr-line>, <country>United States</country></aff>
<aff id="aff2"><sup>2</sup><institution>Hazardous Waste Management Program in King County</institution>, <addr-line>Seattle, WA</addr-line>, <country>United States</country></aff>
<aff id="aff3"><sup>3</sup><institution>National Institute for Occupational Safety and Health, Respiratory Health Division, Field Studies Branch</institution>, <addr-line>Morgantown, WV</addr-line>, <country>United States</country></aff>
<author-notes>
<fn fn-type="edited-by"><p>Edited by: Kin Bong Hubert Lam, University of Oxford, United Kingdom</p></fn>
<fn fn-type="edited-by"><p>Reviewed by: Hafiz Ahmed, University of Sharjah, United Arab Emirates; M. Jahangir Alam, University of Houston, United States</p></fn>
<corresp id="c001">&#x0002A;Correspondence: Stephen G. Whittaker <email>steve.whittaker&#x00040;kingcounty.gov</email></corresp>
<fn fn-type="other" id="fn001"><p>This article was submitted to Environmental health and Exposome, a section of the journal Frontiers in Public Health</p></fn>
<fn fn-type="other" id="fn002"><p>&#x02020;These authors have contributed equally to this work and share first authorship</p></fn></author-notes>
<pub-date pub-type="epub">
<day>05</day>
<month>03</month>
<year>2021</year>
</pub-date>
<pub-date pub-type="collection">
<year>2021</year>
</pub-date>
<volume>9</volume>
<elocation-id>638082</elocation-id>
<history>
<date date-type="received">
<day>10</day>
<month>12</month>
<year>2020</year>
</date>
<date date-type="accepted">
<day>01</day>
<month>02</month>
<year>2021</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x000A9; 2021 Ceballos, Fellows, Evans, Janulewicz, Lee and Whittaker.</copyright-statement>
<copyright-year>2021</copyright-year>
<copyright-holder>Ceballos, Fellows, Evans, Janulewicz, Lee and Whittaker</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license></permissions>
<abstract><p>Perchloroethylene (PERC) is the most common solvent used for dry cleaning in the United States. PERC is a reproductive toxicant, neurotoxicant, potential human carcinogen, and a persistent environmental pollutant. The Environmental Protection Agency is evaluating PERC under the Frank R. Lautenberg Chemical Safety for the 21st Century Act, which amended the Toxic Substances Control Act (amended TSCA), and has mandated that PERC dry cleaning machines be removed from residential buildings. Some local and state programs are also requiring or facilitating transitions to alternative cleaning technologies. However, the potential for these alternatives to harm human health and the environment is not well-understood. This review describes the issues surrounding the use of PERC and alternative solvents for dry cleaning while highlighting the lessons learned from a local government program that transitioned PERC dry cleaners to the safest current alternative: professional wet cleaning. Implications for future public health research and policy are discussed: (1) we must move away from PERC, (2) any transition must account for the economic instability and cultural aspects of the people who work in the industry, (3) legacy contamination must be addressed even after safer alternatives are adopted, and (4) evaluations of PERC alternatives are needed to determine their implications for the long-term health and sustainability of the people who work in the industry.</p></abstract>
<kwd-group>
<kwd>dry-cleaning</kwd>
<kwd>chlorinated solvents</kwd>
<kwd>human health</kwd>
<kwd>safer alternatives</kwd>
<kwd>PERC</kwd>
<kwd>professional wet cleaning</kwd>
</kwd-group>
<contract-sponsor id="cn001">National Institute of Environmental Health Sciences<named-content content-type="fundref-id">10.13039/100000066</named-content></contract-sponsor>
<counts>
<fig-count count="1"/>
<table-count count="2"/>
<equation-count count="0"/>
<ref-count count="93"/>
<page-count count="12"/>
<word-count count="9357"/>
</counts>
</article-meta>
<notes notes-type="disclaimer"><p>The content and conclusions in this article are those of the author(s) and do not necessarily represent the official position of the U.S. National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention.</p>
</notes>
</front>
<body>
<sec sec-type="intro" id="s1">
<title>Introduction</title>
<sec>
<title>Dry Cleaning and the Use of Perchloroethylene</title>
<p>Dry cleaning uses non-aqueous solvents to clean fabrics (<xref ref-type="bibr" rid="B1">1</xref>). The first dry cleaning operations in the United States (US) date back to the 1800s when people washed fabrics in open tubs with solvents such as gasoline, kerosene, benzene, turpentine, and petroleum and then hung to dry. In the 1900s, the US started using specialized machines for the dry cleaning process. However, the use of highly flammable petroleum solvents caused many fires and explosions, highlighting the need to find a safer alternative. The dry cleaning industry first introduced Stoddard solvent (less flammable than gasoline) followed by several nonflammable halogenated solvents, such as carbon tetrachloride, trichloroethylene (TCE), trichlorotrifluoroethane, and perchloroethylene (PERC). Beginning in the 1940s, PERC&#x02014;also known as tetrachloroethylene or PCE&#x02014;became the most frequently used dry cleaning solvent (<xref ref-type="bibr" rid="B1">1</xref>, <xref ref-type="bibr" rid="B2">2</xref>) and continues to be the primary solvent used to dry clean fabrics both in the US (<xref ref-type="bibr" rid="B3">3</xref>) and the European Union (EU) (<xref ref-type="bibr" rid="B4">4</xref>).</p>
<p>To comply with environmental regulations, dry cleaning machines have evolved through several &#x0201C;generations&#x0201D; to minimize PERC release. The 1st generation machines were &#x0201C;transfer machines,&#x0201D; where cleaned fabrics were manually transferred from the washer to a dryer. Since then, various pollution prevention controls have been implemented through the subsequent generations, culminating in the latest 5th generation machines, which are closed-loop and equipped with refrigerated condensers, carbon absorbers, inductive fans, and sensor-actuated lockout devices (<xref ref-type="bibr" rid="B1">1</xref>, <xref ref-type="bibr" rid="B4">4</xref>&#x02013;<xref ref-type="bibr" rid="B6">6</xref>). As the newer generations of machines were introduced, the amount of PERC used was reduced from 300 to 500 g-PERC/kilogram of fabrics (1st generation) to &#x0003C;10 g-PERC/kilogram cleaned garment (5th generation) (<xref ref-type="bibr" rid="B4">4</xref>). In many EU countries, dry cleaning machines older than 15 years are typically prohibited&#x02014;only 5th generation machines are allowed. However, 4th generation machines may be used if best practices (e.g., good housekeeping, optimal machine operation, and recycling) are implemented and they meet EU emission requirements (<xref ref-type="bibr" rid="B4">4</xref>, <xref ref-type="bibr" rid="B7">7</xref>). The US EPA&#x00027;s National Emission Standards for Hazardous Air Pollutants (NESHAPS) regulations stipulate that 2nd generation machines must be upgraded to 4th generation, and 3rd generation machines must be retrofitted or upgraded to 4th generation machines; only 4th generation and later machines can be sold, leased, or installed (<xref ref-type="bibr" rid="B8">8</xref>).</p>
<p>As of 2017 in the US, there are &#x0007E;20,600 dry cleaning shops and the industry employs nearly 160,000 workers, with &#x0007E;80% identifying as a racial or ethnic minority (<xref ref-type="bibr" rid="B9">9</xref>, <xref ref-type="bibr" rid="B10">10</xref>). The majority of owners are of Korean ancestry (<xref ref-type="bibr" rid="B11">11</xref>). Nationwide, 60&#x02013;65% of dry cleaners use PERC as their primary solvent (<xref ref-type="bibr" rid="B1">1</xref>) and most of the remainder use a high-flashpoint hydrocarbon. Other solvents currently used in the US include butylal, siloxane, liquid carbon dioxide, glycol ethers, and water (professional wet cleaning). In Europe, 60&#x02013;90% of dry cleaning shops use PERC, depending on the country (<xref ref-type="bibr" rid="B4">4</xref>).</p></sec>
<sec>
<title>Health and Environmental Impacts of Perchloroethylene</title>
<p>PERC is a respiratory and skin irritant, neurotoxicant, liver and kidney toxicant, and reproductive and developmental toxicant (<xref ref-type="bibr" rid="B12">12</xref>&#x02013;<xref ref-type="bibr" rid="B17">17</xref>). PERC is also considered a &#x0201C;potential occupational carcinogen&#x0201D; (<xref ref-type="bibr" rid="B18">18</xref>), &#x0201C;likely to be carcinogenic to humans by all routes of exposure&#x0201D; (<xref ref-type="bibr" rid="B14">14</xref>, <xref ref-type="bibr" rid="B19">19</xref>), and &#x0201C;probably carcinogenic to humans&#x0201D; (<xref ref-type="bibr" rid="B20">20</xref>). Neurotoxicity is the most sensitive non-cancer adverse health effect associated with PERC, with negative outcomes occurring even at low-dose exposures (<xref ref-type="bibr" rid="B16">16</xref>). Specifically, chronic (i.e., years) or sub-chronic (i.e., months) PERC exposure in humans has been associated with deficits in color vision and neuropsychological function in both occupational and community exposure studies (<xref ref-type="bibr" rid="B16">16</xref>).</p>
<p>A comprehensive review of 109 occupational studies with personal exposure measures estimated a mean exposure to PERC of 59 parts per million (ppm) among dry cleaning workers (<xref ref-type="bibr" rid="B2">2</xref>), with &#x0003C;10 ppm for spotters, pressers, and counter clerks and &#x0003E;100 ppm for machine operators. Another study in 2014 in The Netherlands surveyed ambient PERC concentrations for 193 dry cleaning shops before and after implementing a certification program that customers can use to select shops that are more safe and environmental friendly (<xref ref-type="bibr" rid="B4">4</xref>). Before the program, about 77% of shops reported 15-min time-weighted average (TWA) airborne concentrations &#x02265;35 ppm. After the program, all shops showed a 15-min TWA of &#x0003C;35 ppm. These reductions were encouraging and below the European Union 15-min TWA limit of 40 ppm. However, decrements in visual reproduction, pattern memory, and pattern recognition were found among 65 workers when exposed to an average TWA concentration of &#x0003C;50 ppm for at least 3 years (<xref ref-type="bibr" rid="B21">21</xref>). Decrements on cognitive tests of attention and visual perception were seen in 100 workers with average full-shift TWA exposures of 12 ppm (<xref ref-type="bibr" rid="B22">22</xref>). Decrements were also found with cognitive tests of attention, specifically impaired reaction time, and vigilance among 60 workers typically exposed to TWA of 15 ppm (<xref ref-type="bibr" rid="B23">23</xref>). Reduced performance on vocal reaction time to visual stimuli was seen among 35 workers with TWA as low as 8 ppm (<xref ref-type="bibr" rid="B24">24</xref>). Residents who lived near a dry cleaning shop for an average of 10.6 years (mean indoor air concentration of 0.7 ppm) were found to have reduced cognitive performance on a test of reaction time, vigilance, and visual memory (<xref ref-type="bibr" rid="B25">25</xref>).</p>
<p>Numerous communities have been impacted through exposure to PERC. A cluster of communities on Cape Cod, Massachusetts has been extensively studied following years of PERC exposure. In this region, some water pipes were replaced with vinyl-lined asbestos-cement pipes (<xref ref-type="bibr" rid="B26">26</xref>). The vinyl lining was applied with a slurry of vinyl resin and PERC. Although it was believed that the PERC would evaporate before installation, subsequent water quality testing revealed that the people living in these communities were being exposed to PERC in their drinking water, ranging from 1.5 to 7,750 &#x003BC;g/L (<xref ref-type="bibr" rid="B26">26</xref>, <xref ref-type="bibr" rid="B27">27</xref>). Residents experienced adverse reproductive health outcomes, including delayed time-to-pregnancy (<xref ref-type="bibr" rid="B27">27</xref>, <xref ref-type="bibr" rid="B28">28</xref>), increased risk of placental abruptions (<xref ref-type="bibr" rid="B27">27</xref>, <xref ref-type="bibr" rid="B28">28</xref>), and an increased risk of congenital malformations (<xref ref-type="bibr" rid="B29">29</xref>). Exposure during the prenatal and early childhood period also yielded adverse impacts in adulthood, including reduced performance on neuropsychological tests (<xref ref-type="bibr" rid="B26">26</xref>), increased risk of bipolar disorder (<xref ref-type="bibr" rid="B27">27</xref>, <xref ref-type="bibr" rid="B30">30</xref>), Post Traumatic Stress Disorder (<xref ref-type="bibr" rid="B27">27</xref>, <xref ref-type="bibr" rid="B30">30</xref>), illicit drug use (<xref ref-type="bibr" rid="B31">31</xref>, <xref ref-type="bibr" rid="B32">32</xref>), vision problems (<xref ref-type="bibr" rid="B33">33</xref>), and certain types of cancer (<xref ref-type="bibr" rid="B32">32</xref>, <xref ref-type="bibr" rid="B34">34</xref>, <xref ref-type="bibr" rid="B35">35</xref>). However, no literature was found that describes the regional impact of community PERC exposures through other routes, such as inhalation.</p>
<p>PERC is a persistent pollutant that can contaminate air, soil, groundwater, drinking water, and is potentially toxic to wildlife (<xref ref-type="bibr" rid="B13">13</xref>, <xref ref-type="bibr" rid="B30">30</xref>, <xref ref-type="bibr" rid="B31">31</xref>, <xref ref-type="bibr" rid="B34">34</xref>). The recent draft US EPA risk evaluation on PERC found environmental risks to aquatic organisms (<xref ref-type="bibr" rid="B36">36</xref>). PERC poses a hazard to environmental aquatic receptors, including aquatic invertebrates, fish, and aquatic plants. The most sensitive species for acute toxicity were two daphnid species, <italic>Ceriodaphnia dubia</italic> and <italic>Daphnia magna</italic>; the acute toxicity value was as low as 2.5 milligrams per liter (mg/L). PERC presents an acute hazard to fish based on the mortality of rainbow trout (the most sensitive species) with acute toxicity values as low as 3.6 mg/L for mortality (i.e., the LC<sub>50</sub>&#x02014;the concentration required to kill 50% of the population) (<xref ref-type="bibr" rid="B37">37</xref>). For chronic exposures, PERC is a hazard to aquatic invertebrates, with a chronic toxicity value of 0.5 mg/L, and a chronic toxicity value of 0.8 mg/L for fish (<xref ref-type="bibr" rid="B38">38</xref>). PERC is also a hazard for green microalgae with toxicity values as low as 0.02 mg/L (<xref ref-type="bibr" rid="B38">38</xref>).</p></sec>
<sec>
<title>Regulations for Perchloroethylene</title>
<p>Since 1988, US workplaces have been regulated by the US Occupational Safety and Health Administration (OSHA) with enforceable occupational exposure limits for PERC of 100 ppm for a full-shift (8-h TWA) and 200 ppm for a ceiling limit (<xref ref-type="bibr" rid="B39">39</xref>). The European Union set lower limits than OSHA, with 20 ppm (138 mg/m<sup>3</sup>) for the 8-h TWA and 40 ppm (275 mg/m<sup>3</sup>) for the 15-min short-term TWA (<xref ref-type="bibr" rid="B38">38</xref>). PERC emissions have also been regulated since the 1990s under NESHAPS (<xref ref-type="bibr" rid="B5">5</xref>). By 2003, the California Air Resources Board (CARB) established its Non-Toxic Dry Cleaning Incentive Program (AB998) to help dry cleaners transition away from PERC (<xref ref-type="bibr" rid="B40">40</xref>). In 2007, CARB initiated a phase-out of the use of PERC dry cleaning machines in the State of California by January 1, 2023 (<xref ref-type="bibr" rid="B41">41</xref>). This regulatory action by CARB promoted the adoption of new technologies nationwide.</p>
<p>Under the Clean Air Act (in the Final Amendments to Air Toxics Standards for Perchloroethylene Dry Cleaners), the US EPA stipulates that all PERC machines be removed from residential buildings by December 21, 2020, and replaced with non-PERC technology (<xref ref-type="bibr" rid="B42">42</xref>). PERC is also one of the first ten chemicals being evaluated by EPA under the Frank R. Lautenberg Chemical Safety for the 21st Century Act (Lautenberg Chemical Safety Act), which amended TSCA (amended TSCA) (<xref ref-type="bibr" rid="B43">43</xref>). In 2020, a draft risk evaluation released by the US EPA preliminarily found unreasonable risk to workers, occupational non-users, consumers, bystanders, and the environment from certain uses of PERC, including its use in dry cleaning (<xref ref-type="bibr" rid="B36">36</xref>). Consequently, the US EPA may issue a national ban on the use of PERC in dry cleaning by 2021. None of the EU countries have banned the use of PERC in dry cleaning because they considered that the health and safety of dry cleaners is assured by implementing control measures. Although over 90% of dry cleaning shops still use PERC in France, PERC dry cleaning machines will be phased-out in residential areas by 2022 (<xref ref-type="bibr" rid="B44">44</xref>).</p>
<p>The Toxics Use Reduction Institute (TURI) ranked the available alternatives against PERC, based on technical, economic, environmental, regulatory, and human health criteria. The alternatives were then placed into one of five groupings, with group 1 being the most preferred and group 5 the least preferred. Professional wet cleaning (i.e., water) was the only group 1 alternative, followed by liquid carbon dioxide (group 2); high flashpoint hydrocarbons, butylal (acetal), and propylene glycol ethers (group 3); siloxane (group 4), and finally <italic>n</italic>-propyl bromide (<italic>n</italic>-PB) (group 5) (<xref ref-type="bibr" rid="B45">45</xref>). A comprehensive review of fabric cleaning technologies was also published by investigators at RMIT University, Australia (<xref ref-type="bibr" rid="B46">46</xref>) that focused on ecological attributes and sustainability of safe apparel cleaning method alternatives to PERC. This review emphasized professional wet cleaning as the most desirable alternative.</p>
<p>Given the ample evidence of the health and environmental impacts of PERC, as well as the many regulations and policy initiatives that make the case to minimize or eliminate PERC in the US and abroad, the main objectives of this paper are to (1) provide an overview of the state of the knowledge regarding safer alternatives to PERC in dry cleaning, with emphasis on studies related to human exposure and health; (2) highlight efforts to transition away from PERC in dry cleaning in the US and in particular in King County, WA, USA; and (3) discuss the implications for future public health research and policy for PERC in dry cleaning and safer alternatives.</p></sec></sec>
<sec sec-type="discussion" id="s2">
<title>Discussion</title>
<sec>
<title>Alternatives to Perchloroethylene</title>
<sec>
<title>n-Propyl Bromide</title>
<p>The promotion of <italic>n</italic>-PB (also known as 1-bromopropane or 1-BP) is a case study in &#x0201C;regrettable substitution,&#x0201D; which is defined as &#x0201C;the substitution of hazardous substances with substances with similar chemical structure and similar hazard properties or with substances with other effects of similar concern&#x0201D; (<xref ref-type="bibr" rid="B38">38</xref>). <italic>n</italic>-PB is the only drop-in substitute for PERC (i.e., it can be used in an existing PERC machine with minor modifications). The other alternatives require investment in expensive new dry cleaning equipment. <italic>n</italic>-PB was marketed as a safer alternative because it does not deplete stratospheric ozone. However, this brominated hydrocarbon is extremely toxic to humans via inhalation and is a potent irritant and neurotoxicant. <italic>n</italic>-PB is also reasonably anticipated to be a human carcinogen (<xref ref-type="bibr" rid="B47">47</xref>). In 2008, a case study was published that a dry cleaner located in New Jersey developed neurological symptoms after switching from PERC to <italic>n</italic>-PB (<xref ref-type="bibr" rid="B48">48</xref>). Also in New Jersey, exceedances of the ACGIH Threshold Limit Value (TLV) of 10 ppm for <italic>n</italic>-PB (<xref ref-type="bibr" rid="B49">49</xref>) were documented in dry cleaning shops that had switched from PERC (<xref ref-type="bibr" rid="B50">50</xref>). The authors surmised that leakage of <italic>n</italic>-PB from these machines likely reflected the relatively poor condition of the aging PERC dry cleaning equipment and failure to make needed modifications. Along with PERC, <italic>n</italic>-PB is one of the first ten chemicals being evaluated under the amended TSCA (<xref ref-type="bibr" rid="B51">51</xref>).</p></sec>
<sec>
<title>Volatile Methyl Siloxanes</title>
<p>Decamethylcyclopentasiloxane or D5, a volatile methyl siloxane, is a colorless, odorless liquid and is not considered a Volatile Organic Compound (VOC) per state and federal air quality regulations. However, there are concerns about the global environmental distribution of this chemical class (<xref ref-type="bibr" rid="B52">52</xref>). Although the Canadian government recognized the environmental persistence of siloxanes, in 2013 it concluded that they do not pose a threat to the environment (<xref ref-type="bibr" rid="B53">53</xref>). A chronic toxicity study in female rats suggested that siloxanes caused uterine cancer at the highest concentration (<xref ref-type="bibr" rid="B54">54</xref>, <xref ref-type="bibr" rid="B55">55</xref>). However, the study authors concluded that the findings of uterine tumors in rats are not relevant to humans. The 2014 Safety Data Sheet (SDS) reviewed by the New York State Department of Environmental Conservation (NYSDEC) states that &#x0201C;This product is not considered to be a carcinogen by IARC, ACGIH, NTP, or OSHA&#x0201D; (<xref ref-type="bibr" rid="B56">56</xref>). In conclusion, although the carcinogenicity data for siloxanes are equivocal, a meta-analysis of the toxicological data presented in the Toxnot hazard screening tool revealed that this chemical class poses a very high hazard for environmental persistence (<xref ref-type="bibr" rid="B57">57</xref>).</p></sec>
<sec>
<title>Glycol Ethers</title>
<p>Several glycol ether formulations are available, including dipropylene glycol tert-butyl ethers (DPTB), dipropylene glycol n-butyl ether (DPNB), and propylene glycol t-butyl ether (PGtBE). These are organic and biodegradable solvents with low volatility and a high flashpoint. Brand names include Rynex&#x000AE; and Solvair&#x000AE;. There is limited information about the toxicity of DPNB and DPTB. The California Office of Environmental Health Hazard Assessment (OEHHA) lists PGtBE as a potential carcinogen for consideration under Proposition 65 (<xref ref-type="bibr" rid="B58">58</xref>).</p></sec>
<sec>
<title>Butylal</title>
<p>Butylal is marketed by Kreussler GmbH as Solvon K4<sup>TM</sup> and is part of a relatively new dry cleaning process called System K4<sup>TM</sup> (<xref ref-type="bibr" rid="B59">59</xref>). Solvon K4<sup>TM</sup> is composed primarily of butylal, which is a diether acetal. Synonyms for butylal include dibutoxymethane, 1-(butoxymethoxy)butane, and formaldehyde dibutyl acetal. According to the manufacturer, n-butyl alcohol (1-butanol) and formaldehyde are present at &#x0003C;0.5 and &#x0003C;0.05%, respectively (<xref ref-type="bibr" rid="B60">60</xref>). While butylal is reportedly stable at pHs between 4 and 14, the solvent might theoretically hydrolyze in the dry-cleaning machine to create formaldehyde in the presence of acid and heat.</p>
<p>Although the solvent is reportedly slightly biodegradable, there is little published information concerning its aquatic toxicity (<xref ref-type="bibr" rid="B61">61</xref>). An LC<sub>50</sub> for Solvon K4<sup>TM</sup> of 45.7 mg/L was derived in a 96-h static renewal fish bioassay with juvenile rainbow trout (<xref ref-type="bibr" rid="B62">62</xref>); PERC was found to be greater than ten times more toxic than Solvon K4<sup>TM</sup> in the same bioassay (PERC LC<sub>50</sub> = 3.61 mg/L) (<xref ref-type="bibr" rid="B37">37</xref>).</p>
<p>The available data on butylal&#x00027;s effects on human health are limited to dermal and oral exposures (<xref ref-type="bibr" rid="B63">63</xref>). TURI concluded that toxicological data are lacking for this solvent, rendering the human health assessment incomplete (<xref ref-type="bibr" rid="B45">45</xref>).</p>
<p>Inhalation exposure assessment of dry cleaners using Solvon-K4<sup>TM</sup> revealed that the highest exposures (up to 1.9 ppm of butylal) were during pressing, spot cleaning, as well as loading and unloading the dry cleaning machine (<xref ref-type="bibr" rid="B64">64</xref>, <xref ref-type="bibr" rid="B65">65</xref>). The operator wore leather gloves to clean out the still bottoms and butylal was detected in all four dermal samples from the operator&#x00027;s gloved hands. Although no occupational exposure limits exist for butylal, there is a risk of skin irritation (<xref ref-type="bibr" rid="B66">66</xref>). When control banding techniques were used to assess inhalation and dermal risks (<xref ref-type="bibr" rid="B64">64</xref>), the exposures noted at these shops suggested that better controls were needed. Further, inhalation of formaldehyde and butanol (potential hydrolysis products of butylal) were also assessed but exposures were either very low or not detected.</p></sec>
<sec>
<title>High-Flashpoint Hydrocarbons</title>
<p>These petroleum-based solvents are composed of aliphatic hydrocarbons and have relatively high flammability (flashpoints of 140&#x02013;150&#x000B0;F) and volatility. Examples of these solvents include Exxon-Mobil&#x00027;s DF-2000<sup>TM</sup> and Chevron Phillips&#x00027; EcoSolv&#x000AE;. They are classified as synthetic hydrocarbons and are produced using specific feedstocks and process conditions that yield isoparaffins that are low in impurities (<xref ref-type="bibr" rid="B67">67</xref>). Chemical analysis of DF-2000<sup>TM</sup> and EcoSolv&#x000AE; confirmed that they contain between 11 and 15 carbons as their primary structural backbone (i.e., C11 to C15) and do not contain detectable levels of benzene or other hazardous aromatic hydrocarbons (<xref ref-type="bibr" rid="B64">64</xref>, <xref ref-type="bibr" rid="B65">65</xref>, <xref ref-type="bibr" rid="B68">68</xref>, <xref ref-type="bibr" rid="B69">69</xref>). Both products are essentially insoluble in water and failed to elicit mortality to juvenile rainbow trout at the highest test concentrations (5,000 mg/L for DF-2000<sup>TM</sup> and 100 mg/L for EcoSolv&#x000AE;). In the DF-2000<sup>TM</sup> bioassay, the measured concentration in the test vessel containing 5,000 mg/L of solvent was less than the reporting detection limit of 235 micrograms per liter (&#x003BC;g/L) (<xref ref-type="bibr" rid="B68">68</xref>, <xref ref-type="bibr" rid="B69">69</xref>).</p>
<p>The Hazardous Waste Management Program in King County, WA, USA (Haz Waste Program) reviewed these products and concluded that the uncertainty concerning the toxicological properties of this chemical class reflects: (1) the inclusion of diverse products by some investigators in the category of &#x0201C;hydrocarbon dry cleaning solvents,&#x0201D; some of which may contain benzene and other hazardous substances (e.g., Stoddard solvent), and (2) the inadequacy of Chemical Abstract Service (CAS) numbers to uniquely identify specific products within this chemical class; the assigned CAS numbers apply primarily to feedstocks, rather than the finished products (<xref ref-type="bibr" rid="B68">68</xref>). However, the authors concluded that there are data gaps in their toxicity and bioaccumulative potential. Because high-flashpoint hydrocarbons are regarded as VOCs by state and federal agencies, they can have adverse impacts on ambient air quality (<xref ref-type="bibr" rid="B68">68</xref>).</p>
<p>Inhalation and dermal exposure assessment of dry cleaners using DF-2000<sup>TM</sup> revealed that the highest personal airborne exposures occurred when workers loaded and unloaded the dry cleaning machines and pressed dry cleaned fabrics. The highest detected full-shift air concentration was 21 milligrams/cubic meter (mg/m<sup>3</sup>), which is considerably lower than the occupational exposure limit of 300 mg/m<sup>3</sup> (i.e., the GESTIS International 8-h Limit Value for CAS number 64742-48-9) (<xref ref-type="bibr" rid="B70">70</xref>). The greatest opportunity for dermal exposure occurred when solid waste (still bottoms) was removed from the dry cleaning machine for disposal; DF-2000<sup>TM</sup> was detected at very low levels in two of the six dermal samples from the dry cleaners&#x00027; gloved hands (<xref ref-type="bibr" rid="B64">64</xref>, <xref ref-type="bibr" rid="B65">65</xref>).</p></sec>
<sec>
<title>Liquid Carbon Dioxide</title>
<p>This technology combines carbon dioxide with specialized detergents under high pressure (700 psi) and is considered to be non-toxic, non-flammable, non-corrosive, and environmentally safe (<xref ref-type="bibr" rid="B46">46</xref>). However, the high cost of the initial capital investment in addition to the ongoing costs for specialized detergents and maintenance has made this technology prohibitively expensive for most dry cleaners (<xref ref-type="bibr" rid="B45">45</xref>).</p></sec>
<sec>
<title>Professional Wet Cleaning (PWC)</title>
<p>In PWC, fabrics are cleaned with water and detergent in a computer-controlled washing machine with multiple fabric-specific cleaning programs. In advanced PWC machines, additional products are added to the washing drum, depending on the type of fabric being cleaned. These products protect fibers during drying, prevent dye bleeding, provide suppleness to leather, etc. The washed fabrics are then placed in a specialized dryer equipped with moisture sensors to ensure that fabrics do not shrink after excessive drying. In contrast to PERC and most other solvent-based dry cleaning methods, PWC does not generate hazardous organic solvent waste (<xref ref-type="bibr" rid="B71">71</xref>). Another benefit of PWC is that the ancillary process chemicals, including detergents and spot cleaners, are typically less hazardous than those used in PERC and high-flashpoint hydrocarbon dry cleaning (<xref ref-type="bibr" rid="B72">72</xref>&#x02013;<xref ref-type="bibr" rid="B74">74</xref>).</p>
<p>Although PWC has been used as an alternative to PERC in the US for over two decades, the dry cleaning community has been slow to adopt this technology. The benefits of PWC and the industry pressures and other factors that have prevented wider adoption of this technology were described as early as 2001 (<xref ref-type="bibr" rid="B75">75</xref>). Others have also documented the considerable health, environmental, and economic benefits of using PWC relative to PERC (<xref ref-type="bibr" rid="B4">4</xref>, <xref ref-type="bibr" rid="B45">45</xref>, <xref ref-type="bibr" rid="B46">46</xref>, <xref ref-type="bibr" rid="B76">76</xref>&#x02013;<xref ref-type="bibr" rid="B78">78</xref>).</p></sec></sec>
<sec>
<title>Promoting Safer Alternatives to PERC in the United States</title>
<p>Several jurisdictions have encouraged or mandated a transition away from PERC. The State of California provided $10,000 grants to PERC dry cleaners to transition to non-toxic and non-smog forming technologies such as PWC and liquid carbon dioxide (<xref ref-type="bibr" rid="B40">40</xref>). The Commonwealth of Massachusetts offered grants of up to $10,000 to transition away from PERC (<xref ref-type="bibr" rid="B79">79</xref>). The City of Minneapolis banned the use of PERC and became the first PERC-free city in the nation in January 2018 (<xref ref-type="bibr" rid="B80">80</xref>). The City of Philadelphia extended the US EPA phase-out of PERC dry cleaning operations located in residential buildings to include hospitals, daycares, schools, health clinics, community centers, and recreation areas (<xref ref-type="bibr" rid="B81">81</xref>). The City of New York, among other actions, required all dry cleaners to post the type of chemicals they use via public &#x0201C;right to know&#x0201D; legislation (<xref ref-type="bibr" rid="B82">82</xref>).</p>
<sec>
<title>Promoting Safer Alternatives to PERC in King County, WA, USA</title>
<sec>
<title>Learning From the Industry</title>
<p>The Haz Waste Program has provided technical and financial assistance to the local dry cleaning community since the 1990s. These efforts have included technical and financial assistance with pollution prevention, enrollment in an environmental recognition program (&#x0201C;EnviroStars&#x0201D;), grants for alternative dry cleaning equipment, exposure monitoring, and sponsorship of local dry cleaning association meetings (<xref ref-type="bibr" rid="B71">71</xref>). The program has also conducted many interviews and focus groups with dry cleaning business owners and vendors.</p>
<p>In 2010, a countywide survey (<xref ref-type="bibr" rid="B6">6</xref>, <xref ref-type="bibr" rid="B83">83</xref>) revealed that 69% of dry cleaners in King County, WA, USA, were still using PERC and that cost was the principal barrier to shops adopting safer technologies. Other key findings included that 80% of shops were owned and operated by immigrants from South Korea. Subsequent field visits revealed that when shops had employees, they were typically people of Latin American descent (<xref ref-type="bibr" rid="B84">84</xref>). From an equity and social justice perspective, the program considered this to be a vulnerable and underserved population that requires particular protection from the adverse health effects associated with PERC and other hazardous substances. The median age of PERC dry cleaning machines in King County, WA, USA was 18 years, which exceeds their expected service life of &#x0007E;15 years (<xref ref-type="bibr" rid="B6">6</xref>, <xref ref-type="bibr" rid="B83">83</xref>). Older machines can be prone to leaks and other mechanical problems.</p></sec>
<sec>
<title>Selection of the Preferred Alternatives</title>
<p>The Haz Waste Program reviewed the available alternatives to select a technology to promote in King County, WA, USA. Part of this review process included evaluating safer alternatives that had been adopted elsewhere in the US. For example, the NYSDEC has reviewed most of the common alternative dry cleaning solvents, and all but <italic>n</italic>-PB are currently approved for use in New York State (<xref ref-type="bibr" rid="B85">85</xref>).</p>
<p>Upon discussing alternatives to PERC with the King County dry cleaning community, their preferred system was high-flashpoint hydrocarbon (<xref ref-type="bibr" rid="B71">71</xref>). In King County, WA, USA the primary alternative technologies available to local dry cleaners are high-flashpoint hydrocarbon and butylal (see <xref ref-type="table" rid="T1">Table 1</xref>). The Haz Waste Program was not aware of any local shops that were using <italic>n</italic>-PB, siloxanes, glycol ethers, or liquid carbon dioxide. By 2010, 27% of shops had already adopted high-flashpoint hydrocarbon in King County, WA, USA (<xref ref-type="bibr" rid="B6">6</xref>, <xref ref-type="bibr" rid="B83">83</xref>). Stated reasons for doing so included the belief that high-flashpoint hydrocarbon can clean all fabrics and is similar enough to PERC that little training is required for owners and staff, resulting in less downtime.</p>
<table-wrap position="float" id="T1">
<label>Table 1</label>
<caption><p>The most prevalent cleaning systems in King County, WA, USA.</p></caption>
<table frame="hsides" rules="groups">
<thead><tr>
<th valign="top" align="left"><bold>Cleaning system</bold></th>
<th valign="top" align="left"><bold>Solvent type</bold></th>
<th valign="top" align="left"><bold>Example products (manufacturer)</bold></th>
<th valign="top" align="center"><bold>Flashpoint<bold><xref ref-type="table-fn" rid="TN1"><sup>a</sup></xref></bold></bold></th>
<th valign="top" align="center"><bold>LC<sub><bold>50</bold></sub> (fish bioassay)<bold><xref ref-type="table-fn" rid="TN2"><sup>b</sup></xref></bold></bold></th>
<th valign="top" align="center"><bold>Generates hazardous waste?<bold><xref ref-type="table-fn" rid="TN3"><sup>c</sup></xref></bold></bold></th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">PERC</td>
<td valign="top" align="left">Chlorinated hydrocarbon</td>
<td valign="top" align="left">PerSec&#x000AE; (R.R. Streets &#x00026; Co., Inc.)</td>
<td valign="top" align="center">None</td>
<td valign="top" align="center">3.61 mg/L</td>
<td valign="top" align="center">Yes</td>
</tr>
<tr>
<td valign="top" align="left">Butylal</td>
<td valign="top" align="left">Diether acetal</td>
<td valign="top" align="left">Solvon K4<sup>TM</sup> (Kreussler GmbH)</td>
<td valign="top" align="center">143.6&#x000B0;F</td>
<td valign="top" align="center">45.7 mg/L</td>
<td valign="top" align="center">Yes</td>
</tr>
<tr>
<td valign="top" align="left">High-flashpoint hydrocarbon</td>
<td valign="top" align="left">Isoparaffin (C11-C15)</td>
<td valign="top" align="left">DF-2000<sup>TM</sup> (Exxon-Mobil)</td>
<td valign="top" align="center">142&#x000B0;F</td>
<td valign="top" align="center">&#x0003E;5,000 mg/L</td>
<td valign="top" align="center">Yes</td>
</tr>
<tr>
<td/>
<td/>
<td valign="top" align="left">EcoSolv&#x000AE; (Chevron Phillips)</td>
<td valign="top" align="center">144&#x000B0;F</td>
<td valign="top" align="center">&#x0003E;100 mg/L</td>
<td valign="top" align="center">Yes</td>
</tr>
<tr>
<td valign="top" align="left">PWC</td>
<td valign="top" align="left">Water</td>
<td valign="top" align="left">Not applicable</td>
<td valign="top" align="center">Not applicable</td>
<td valign="top" align="center">Not applicable</td>
<td valign="top" align="center">No</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="TN1">
<label>a</label>
<p><italic>From applicable Safety Data Sheets (<xref ref-type="bibr" rid="B63">63</xref>, <xref ref-type="bibr" rid="B86">86</xref>&#x02013;<xref ref-type="bibr" rid="B88">88</xref>)</italic>.</p>
</fn>
<fn id="TN2">
<label>b</label>
<p><italic>96-h juvenile rainbow trout bioassays (<xref ref-type="bibr" rid="B37">37</xref>, <xref ref-type="bibr" rid="B69">69</xref>, <xref ref-type="bibr" rid="B72">72</xref>, <xref ref-type="bibr" rid="B89">89</xref>)</italic>.</p>
</fn>
<fn id="TN3">
<label>c</label>
<p><italic>Organic solvent waste, per King County Ecology&#x00027;s Dangerous Waste Regulations for Washington State (<xref ref-type="bibr" rid="B72">72</xref>, <xref ref-type="bibr" rid="B73">73</xref>, <xref ref-type="bibr" rid="B89">89</xref>&#x02013;<xref ref-type="bibr" rid="B91">91</xref>)</italic>.</p></fn>
</table-wrap-foot>
</table-wrap>
<p>Before the advent of the latest PWC technology, the Haz Waste Program provided financial incentives for shops to transition principally to high-flashpoint hydrocarbon (see <xref ref-type="table" rid="T2">Table 2</xref>). However, dry cleaners continued to use hazardous spot cleaning products from their PERC operations and the solid waste stream (i.e., still bottoms) was determined to be a dangerous waste, based on its toxicity in a fish bioassay (<xref ref-type="bibr" rid="B72">72</xref>, <xref ref-type="bibr" rid="B73">73</xref>, <xref ref-type="bibr" rid="B89">89</xref>, <xref ref-type="bibr" rid="B90">90</xref>). The Haz Waste Program also witnessed contamination of high-flashpoint hydrocarbon machines and waste streams from the use of process chemicals that contain chlorinated hydrocarbons (i.e., PERC and TCE).</p>
<table-wrap position="float" id="T2">
<label>Table 2</label>
<caption><p>Summary descriptors of dry cleaning shop transitions to safer dry cleaning alternatives in King Country, WA, USA.</p></caption>
<table frame="hsides" rules="groups">
<thead><tr>
<th valign="top" align="left"><bold>Alternative dry cleaning system</bold></th>
<th valign="top" align="left"><bold>Disadvantages of alternative system</bold></th>
<th valign="top" align="left"><bold>Advantages of alternative system</bold></th>
<th valign="top" align="center"><bold>Dates transitioned by King County</bold></th>
<th valign="top" align="center"><bold>Financial incentive from King County</bold></th>
<th valign="top" align="center"><bold>Number of shops transitioned with King County assistance</bold></th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Solvon K4</td>
<td valign="top" align="left">&#x02022; Generates hazardous waste<break/>&#x02022; Potential formaldehyde byproduct<break/>&#x02022; Solvent used occasionally for spot cleaning fabrics<break/>&#x02022; Strong odor<break/>&#x02022; More flammable than PERC (Class IIIA solvent)<break/>&#x02022; Toxicity poorly characterized<break/>&#x02022; Proprietary solvent from a single manufacture<break/>&#x02022; Relatively expensive</td>
<td valign="top" align="left">&#x02022; Less toxic than PERC<break/>&#x02022; Safer spotting chemicals<break/>&#x02022; Similar to PERC cleaning process</td>
<td valign="top" align="center">None</td>
<td valign="top" align="center">None</td>
<td valign="top" align="center">None</td>
</tr>
<tr>
<td valign="top" align="left">High-flashpoint hydrocarbon</td>
<td valign="top" align="left">&#x02022; Generates hazardous waste<break/>&#x02022; More flammable than PERC (Class IIIA solvent)<break/>&#x02022; Often used with legacy spotting chemicals<break/>&#x02022; Machines inadvertently contaminated with PERC process chemicals</td>
<td valign="top" align="left">&#x02022; No odors<break/>&#x02022; Relatively inexpensive solvent<break/>&#x02022; Available from multiple manufacturers<break/>&#x02022; Similar to PERC cleaning process<break/>&#x02022; Toxicity relatively well-characterized</td>
<td valign="top" align="center">2012&#x02013;2014</td>
<td valign="top" align="center">$10,000&#x02013;15,000</td>
<td valign="top" align="center">9</td>
</tr>
<tr>
<td valign="top" align="left">PWC</td>
<td valign="top" align="left">&#x02022; Skepticism of dry cleaners<break/>&#x02022; Relatively expensive equipment<break/>&#x02022; Modern tensioning equipment needed<break/>&#x02022; New cleaning system&#x02014;training needed<break/>&#x02022; Customer concerns<break/>&#x02022; Adequate boiler needed</td>
<td valign="top" align="left">&#x02022; No hazardous waste<break/>&#x02022; No odors<break/>&#x02022; Reduced resource usage<break/>&#x02022; Lower utility bills<break/>&#x02022; Provided spot cleaners are low toxicity</td>
<td valign="top" align="center">2012&#x02013;2014<break/><break/><break/><break/> 2018&#x02013;2020</td>
<td valign="top" align="center">$10,000&#x02013;15,000<break/><break/><break/><break/> $20,000</td>
<td valign="top" align="center">2<break/><break/><break/><break/> 27</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>The butylal process was also considered for promotion by the Haz Waste Program. An added benefit of this system is that it includes a suite of spot cleaning chemicals that appear to be relatively safe (<xref ref-type="bibr" rid="B72">72</xref>). However, butylal was also ultimately rejected because of uncertainties concerning the solvent&#x00027;s toxicological properties and that the still bottoms were determined to be extremely hazardous waste (<xref ref-type="bibr" rid="B72">72</xref>, <xref ref-type="bibr" rid="B89">89</xref>, <xref ref-type="bibr" rid="B90">90</xref>).</p>
<p>The program learned that the local dry cleaning community was skeptical about the ability of PWC to clean all &#x0201C;dry clean only&#x0201D; fabrics, especially wools and silks. Concerns were also expressed about potential shrinkage and the manual labor required to measure garments before cleaning to stretch them back to their original dimensions. However, a new generation of PWC equipment appeared in approximately 2017, and program staff witnessed the successful cleaning of wool dress suits and silk garments in three shops. Interviews with these shop owners and their equipment vendors led the program to conclude that PWC had become a viable alternative to PERC dry cleaning and that it would promote the adoption of PWC exclusively. The program concluded that the alternative organic solvents should no longer be considered for the financial incentive initiative because: (1) they are more flammable than PERC, (2) they generate hazardous waste, and (3) there are numerous uncertainties and data gaps associated with the toxicology of some of these products. The selection of PWC as the preferred alternative represented a precautionary approach to help avoid a regrettable substitution.</p></sec>
<sec>
<title>Implementing a Safer Alternatives Strategy</title>
<p>Having selected PWC as the preferred alternative to PERC, the Haz Waste Program reviewed the approaches used by other jurisdictions to promote adoption. These included financial assistance, equipment demonstrations, bans, and signage requirements (<xref ref-type="bibr" rid="B71">71</xref>). These approaches were evaluated against four criteria: (1) human health and environmental impact, (2) financial impact on dry cleaner owners and workers, (3) feasibility, and (4) implementation cost. The program selected the strategy of financial incentives because it had a high likelihood of improved human health/environment protection, minimized the financial impact to dry cleaners, and limited the risk of &#x0201C;regrettable substitutions.&#x0201D; The program chose not to implement a ban because the US EPA was reviewing PERC under the amended TSCA and its decision would likely preempt any regulations introduced in King County, WA, USA. Generally, state and local action on a chemical is preempted when EPA has acted by either finding a chemical to be safe or by regulating a chemical to address identified risks. State action is also temporarily &#x0201C;paused&#x0201D; when EPA is evaluating a chemical.</p>
<p>The program also decided that pursuing a signage regulation would be time-consuming and have little impact. Therefore, the program initiated a pilot project in which dry cleaners would be reimbursed $20,000 if they switched from PERC to PWC (<xref ref-type="bibr" rid="B71">71</xref>). The program reserved the option to implement equipment demonstrations, if necessary. <xref ref-type="fig" rid="F1">Figure 1</xref> depicts a photo of one of the participating dry cleaning shops in the transitioning program.</p>
<fig id="F1" position="float">
<label>Figure 1</label>
<caption><p>Photo of the owner at one of the dry cleaner shops participating in the KIng County, WA transition program. Credits to Tae Park (Sun Cleaners) and the Hazardous Waste Management Program in King County, Washington, USA.</p></caption>
<graphic xlink:href="fpubh-09-638082-g0001.tif"/>
</fig>
<p>The strategy to promote the adoption of PWC in King County, WA, USA is described in detail in a technical report (<xref ref-type="bibr" rid="B71">71</xref>). Ultimately, the initiative&#x00027;s success hinged on the credible scientific information about PWC already gathered by other programs and the participation of a local Korean-owned vendor, who had become a dealer for Miele PWC equipment. This vendor was established and trusted in the local Korean dry cleaning community because they were already supplying solvents, equipment, and other materials to the industry. The program used an equity and social justice lens in its intervention. Interactions with the dry cleaning community needed to be conducted in a culturally appropriate manner, including working closely with the communities to hear their needs, working with community members (including vendors) to promote the program, soliciting community input on the development of promotional materials, providing materials in their native language, and providing interpretation services, when necessary. Further, the Washington State Department of Ecology also collaborated with the program extensively, providing technical assistance and ensuring that all procedures conformed to local environmental regulatory requirements.</p>
<p>Starting in April 2018, the vendor visited their existing PERC dry cleaning clients to advocate for PWC. The program provided the vendor with promotional materials, which they distributed to the shops. Once the shop owners expressed interest to the vendor, program staff visited the business, usually with a Korean vendor representative. The vendor made introductions to the shop owner and provided interpretation help, as needed. At this visit, program staff administered a survey, inventoried process chemicals, performed leak detection on the PERC machine with a photoionization detector (PID), and provided the paperwork for reimbursement. Of the approximately 65 remaining PERC dry cleaning shops in King County, WA, USA, 27 have taken advantage of the reimbursement program and switched to PWC as of October 2020 (<xref ref-type="table" rid="T2">Table 2</xref>).</p>
<p>Follow-up surveys were conducted 6 months after each shop transitioned to PWC, and the products used with the new equipment were inventoried. Once shops made the switch, they no longer used a hazardous solvent to clean fabrics and no longer generated organic solvent hazardous wastes. Also, the ancillary process chemicals provided by the PWC vendor (spotting agents, etc.) contain products with ingredients of lower toxicity than those used in PERC operations (<xref ref-type="bibr" rid="B74">74</xref>). Although utility data proved difficult to review, two shops that continually flushed cooling water through their PERC machines reduced their water usage and utility bills dramatically after transitioning to PWC. Other studies have documented significantly lower consumption of natural resources (i.e., gas, electricity, and water) when using PWC compared to PERC (<xref ref-type="bibr" rid="B46">46</xref>, <xref ref-type="bibr" rid="B76">76</xref>&#x02013;<xref ref-type="bibr" rid="B78">78</xref>). Most shop owners expressed satisfaction with their decision to adopt PWC, with some suggesting that their health had improved (<xref ref-type="bibr" rid="B71">71</xref>).</p></sec></sec>
<sec>
<title>Implications for Future Public Health Research and Policy</title>
<p>Dry cleaning businesses have promoted the adoption of alternative technologies in dry cleaning as &#x0201C;green,&#x0201D; in an attempt to change public perception given the increased public awareness of PERC health and environmental issues. Despite marketing efforts to use the technology changes to increase clientele and attract new users, the dry cleaning industry is in a state of decline (<xref ref-type="bibr" rid="B92">92</xref>). The industry&#x00027;s financial stress stem from the Great Recession in the US (December 2007&#x02013;June 2009) and the current recession (2020). This decline also reflects a shrinking customer base because of: (1) changes in the types of fabrics now in common use, many of which do not require dry cleaning; (2) technological advances in residential washing machines and dryers, which allow the cleaning of wool and other delicate fabrics at home; (3) the availability of in-house dry cleaning and &#x0201C;wash &#x00026; fold services&#x0201D; at several major corporations; and (4) extended telecommuting and other alternative work arrangements in which workers are no longer required to report to an office. Business owners are also retiring, especially immigrants from South Korea. In King County, WA, USA, we are also witnessing considerable consolidation in this industry, insofar as businesses with relatively large facilities and multiple cleaning machines are purchasing neighborhood dry cleaning shops and converting them to drop shops, where fabrics are dropped off by customers and then transported to the central facility for cleaning. Although there are health and environmental benefits to conducting cleaning in a light industrial setting distant from neighborhoods, this development is contributing to the demise of the remaining smaller neighborhood shops that are often owned by financially vulnerable business owners, with significant impacts to their employees, who are disproportionately of Asian and Latin American descent.</p>
<p>Regardless of the economic challenges faced by the dry cleaning industry in the US, dry cleaning shops will continue to operate, especially in larger urban areas, and it is important to ensure the health and safety of the workers and the communities served by these small businesses. Therefore, research efforts should be directed toward understanding and tracking the long-term health effects of exposures to past and present dry cleaning workers, their families, and the surrounding community. Research is especially needed given the lack of health surveillance within these populations of interest. In particular, it would be important to follow the health of workers in dry cleaning shops using alternatives to PERC, where we do not have comprehensive toxicological and human exposure and health information. The impacts of using spot-cleaning agents and other ancillary process chemicals should also be evaluated.</p>
<p>Even if PERC is eliminated in the US dry cleaning industry, it will be necessary to continue to understand the benefits and health impacts from transitioning to alternative solvents and technologies to avoid regrettable substitutions. This feedback loop to assess real-life scenarios of these new technologies, especially as machines age, should be part of the safer alternative strategies, as suggested by OSHA in their guidance Transitioning to Safer Chemicals (Step 7 Evaluate) (<xref ref-type="bibr" rid="B93">93</xref>). It is vital to examine the short- and long-term health impacts of PERC exposures on affected workers and communities (<xref ref-type="bibr" rid="B3">3</xref>).</p>
<p>A draft risk evaluation report for PERC was released by US EPA in April 2020 and the public comment period closed July 6, 2020 (<xref ref-type="bibr" rid="B36">36</xref>). EPA&#x00027;s draft risk evaluation preliminarily found unreasonable risk to workers, occupational non-users, consumers, bystanders, and the environment from certain uses. The primary health risk identified in the draft risk evaluation is neurological effects from short- and long-term exposure. The risk to consumers is from skin exposure to items cleaned with PERC. The agency also found environmental risks to aquatic organisms.</p>
<p>If the final risk evaluation determines that PERC presents an unreasonable risk to human health and the environment, the US EPA would take a risk management action under TSCA. The risk evaluation should be finalized by the end of 2020. Once final and if risks are found, that starts a 1-year clock to propose a risk management rule. The US EPA also has the option to establish regulatory restrictions on the manufacture, processing, distribution, use, or disposal of PERC to eliminate the unreasonable risk. The US EPA is given a range of risk management options under TSCA, including labeling, recordkeeping or notice requirements, actions to reduce human exposure or environmental release, and a ban on the chemical or of certain uses. Like the prioritization and risk evaluation processes, there is an opportunity for public comment on any proposed risk management actions.</p></sec></sec></sec>
<sec sec-type="conclusions" id="s3">
<title>Conclusions</title>
<p>Although local and state policies in the US have played a major role in transitioning dry cleaners from PERC to safer alternatives, identifying safer and more sustainable alternatives to PERC has not been straightforward. Some of these alternatives have been promoted as safe and environmentally friendly, although their effects on human health and the environment may have not been well characterized. Many of the alternative solvents are relatively new products with no established occupational exposure limits (e.g., glycol ethers and Solvon K4). Unfortunately, the search for dry cleaning solvents has resulted in regrettable substitutions, such as the use of <italic>n</italic>-PB. However, with recent improvements in PWC, this technology has become an alternative to PERC that does not use potentially harmful solvents and does not generate organic hazardous waste. To ensure the sustainability of the fabric cleaning industry and the health of workers and nearby communities, continued investment in transition programs and research into safer alternatives to PERC is needed. Lastly, any approach to promoting safer alternatives should account for the unique financial and cultural characteristics of the industry.</p></sec>
<sec id="s4">
<title>Ethics Statement</title>
<p>Written informed consent was obtained from the individual(s) for the publication of any identifiable images/material in the article.</p></sec>
<sec id="s5">
<title>Author Contributions</title>
<p>DC and SW conceptualized the idea for the manuscript. DC coordinated collaborators and led the writing and reviews of the manuscript. SW led the writing of the case study, the description of solvent alternatives, and reviews of the manuscript. PJ contributed to the writing of the health section of the manuscript and reviewed the manuscript. KF and AE contributed to the writing of the policy section and case study and reviewed the manuscript. EL contributed to the occupational health and exposure limits sections and the review of the article. All authors contributed to the article and approved the submitted version.</p></sec>
<sec sec-type="COI-statement" id="conf1">
<title>Conflict of Interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p></sec>
</body>
<back>
<ack><p>We gratefully acknowledge the assistance and participation of Hazardous Waste Management Program staff, King County&#x00027;s dry cleaners, and the local supplier and vendor community.</p>
</ack>
<ref-list>
<title>References</title>
<ref id="B1">
<label>1.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>EnviroForensics</collab></person-group>. <source>The History of Dry Cleaning Solvents and the Evolution of the Dry Cleaning Machine</source> (<year>2020</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www.enviroforensics.com/blog/the-history-of-dry-cleaning-solvents-and-the-evolution-of-the-dry-cleaning-machine/">https://www.enviroforensics.com/blog/the-history-of-dry-cleaning-solvents-and-the-evolution-of-the-dry-cleaning-machine/</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B2">
<label>2.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gold</surname> <given-names>LS</given-names></name> <name><surname>De Roos</surname> <given-names>AJ</given-names></name> <name><surname>Waters</surname> <given-names>M</given-names></name> <name><surname>Stewart</surname> <given-names>P</given-names></name></person-group>. <article-title>Systematic literature review of uses and levels of occupational exposure to tetrachloroethylene</article-title>. <source>J Occup Environ Hyg.</source> (<year>2008</year>) <volume>5</volume>:<fpage>807</fpage>&#x02013;<lpage>39</lpage>. <pub-id pub-id-type="doi">10.1080/15459620802510866</pub-id><pub-id pub-id-type="pmid">18949603</pub-id></citation></ref>
<ref id="B3">
<label>3.</label>
<citation citation-type="web"><person-group person-group-type="author"><name><surname>US</surname> <given-names>EPA</given-names></name></person-group>. <source>Problem Formulation of the Risk Evaluation for Perchloroethylene</source> (<year>2018</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www.epa.gov/sites/production/files/2018-06/documents/perc_problem_formulation_5-31-2018v3.pdf">https://www.epa.gov/sites/production/files/2018-06/documents/perc_problem_formulation_5-31-2018v3.pdf</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B4">
<label>4.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>CINET</collab></person-group> (<year>2013</year>). <source>Safe and Sustainable Use of Tetrachloroethylene in Professional Textile Cleaning by Best Practice Approach</source> <publisher-loc>Ophemert</publisher-loc>: <publisher-name>CINET Professional Textile Care</publisher-name>. Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://members.cinet-online.com/safe-and-sustainable-use-of-tetrachloroethylene-in-professional-textile-cleaning-by-best-practice-approach/">https://members.cinet-online.com/safe-and-sustainable-use-of-tetrachloroethylene-in-professional-textile-cleaning-by-best-practice-approach/</ext-link> (accessed November 20, 2020).</citation>
</ref>
<ref id="B5">
<label>5.</label>
<citation citation-type="web"><person-group person-group-type="author"><name><surname>US</surname> <given-names>EPA</given-names></name></person-group>. <source>National Emission Standards for Hazardous Air Pollutants Compliance Monitoring</source> (<year>2013</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www.epa.gov/compliance/national-emission-standards-hazardous-air-pollutants-compliance-monitoring">https://www.epa.gov/compliance/national-emission-standards-hazardous-air-pollutants-compliance-monitoring</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B6">
<label>6.</label>
<citation citation-type="web"><person-group person-group-type="author"><name><surname>Whittaker</surname> <given-names>SG</given-names></name> <name><surname>Johanson</surname> <given-names>CA</given-names></name></person-group>. <source>A Profile of the Dry Cleaning Industry in King County, Washington</source> (Report no. LHWMP 0048). <publisher-loc>Seattle, WA</publisher-loc>: <publisher-name>Local Hazardous Waste Management Program in King County</publisher-name> (<year>2011</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://kingcountyhazwastewa.gov/-/media/lhwmp-documents/technical-reports/understanding-the-dry-cleaning-industry/rsh-a-profile-of-the-dry-cleaning-industry-in-king-county.pdf">https://kingcountyhazwastewa.gov/-/media/lhwmp-documents/technical-reports/understanding-the-dry-cleaning-industry/rsh-a-profile-of-the-dry-cleaning-industry-in-king-county.pdf</ext-link> (accessed November 20, 2020). <pub-id pub-id-type="pmid">23858662</pub-id></citation></ref>
<ref id="B7">
<label>7.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>CINET</collab></person-group>. <source>European Legislation PER.</source> <publisher-loc>Ophemert</publisher-loc>: <publisher-name>CINET Professional Textile Care</publisher-name> (<year>2013</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www.cinet-online.com/uploads/files/CINET_European%20Legislation%20PERC.pdf">https://www.cinet-online.com/uploads/files/CINET_European%20Legislation%20PERC.pdf</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B8">
<label>8.</label>
<citation citation-type="web"><person-group person-group-type="author"><name><surname>US</surname> <given-names>EPA</given-names></name></person-group>. <source>Perchloroethylene Dry Cleaners Refined Human Health Risk Characterization</source> (<year>2005</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www.epa.gov/sites/production/files/2015-06/documents/riskassessment_dry_cleaners.pdf">https://www.epa.gov/sites/production/files/2015-06/documents/riskassessment_dry_cleaners.pdf</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B9">
<label>9.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>BLS</collab></person-group>. <source>Occupational Employment and Wages, May 2017. 51-6011 Laundry and Dry-Cleaning Workers</source>. (<year>2018</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www.bls.gov/oes/2017/may/oes516011.htm">https://www.bls.gov/oes/2017/may/oes516011.htm</ext-link> (accessed November 20, 2020).</citation>
</ref>
<ref id="B10">
<label>10.</label>
<citation citation-type="web"><person-group person-group-type="author"><name><surname>Census</surname> <given-names>Bureau</given-names></name></person-group>. <source>2017 SUSB Annual Dataset by Establishment Industry, U.S. &#x00026; States, 6 Digit NAICS</source>. (<year>2018</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www.census.gov/data/datasets/2017/econ/susb/2017-susb.html">https://www.census.gov/data/datasets/2017/econ/susb/2017-susb.html</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B11">
<label>11.</label>
<citation citation-type="web"><person-group person-group-type="author"><name><surname>Kerr</surname> <given-names>WR</given-names></name> <name><surname>Mandorff</surname> <given-names>M</given-names></name></person-group>. <source>Social Networks, Ethnicity, and Entrepreneurship.</source> <publisher-loc>Cambridge, MA</publisher-loc>: <publisher-name>National Bureau of Economic Research</publisher-name> (<year>2019</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www.nber.org/papers/w21597">https://www.nber.org/papers/w21597</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B12">
<label>12.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Aschengrau</surname> <given-names>A</given-names></name> <name><surname>Gallagher</surname> <given-names>LG</given-names></name> <name><surname>Winter</surname> <given-names>M</given-names></name> <name><surname>Butler</surname> <given-names>LJ</given-names></name> <name><surname>Patricia</surname> <given-names>FM</given-names></name> <name><surname>Vieira</surname> <given-names>VM</given-names></name></person-group>. <article-title>Modeled exposure to tetrachloroethylene-contaminated drinking water and the risk of placenta-related stillbirths: a case-control study from Massachusetts and Rhode Island</article-title>. <source>Environ Health Glob Access Sci Source.</source> (<year>2018</year>) <volume>17</volume>:<fpage>58</fpage>. <pub-id pub-id-type="doi">10.1186/s12940-018-0402-1</pub-id><pub-id pub-id-type="pmid">29970097</pub-id></citation></ref>
<ref id="B13">
<label>13.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>ATSDR</collab></person-group>. <source>Public Health Statement for Tetrachloroethylene (PERC)</source> (<year>2015</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www.atsdr.cdc.gov/PHS/PHS.asp?id=263&#x00026;tid=48">https://www.atsdr.cdc.gov/PHS/PHS.asp?id=263&#x00026;tid=48</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B14">
<label>14.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>ATSDR</collab></person-group>. <source>Toxicological Profile for Tetrachloroethylene (PERC).</source> <publisher-loc>Atlanta, GA</publisher-loc>: <publisher-name>Agency for Toxic Substances and Disease Registry</publisher-name> (<year>2019</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www.atsdr.cdc.gov/toxprofiles/tp.asp?id=265&#x00026;tid=48">https://www.atsdr.cdc.gov/toxprofiles/tp.asp?id=265&#x00026;tid=48</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B15">
<label>15.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chiu</surname> <given-names>WA</given-names></name> <name><surname>Jinot</surname> <given-names>J</given-names></name> <name><surname>Scott</surname> <given-names>CS</given-names></name> <name><surname>Makris</surname> <given-names>SL</given-names></name> <name><surname>Cooper</surname> <given-names>GS</given-names></name> <name><surname>Dzubow</surname> <given-names>RC</given-names></name> <etal/></person-group>. <article-title>Human health effects of trichloroethylene: Key findings and scientific issues</article-title>. <source>Environ Health Perspect.</source> (<year>2013</year>) <volume>121</volume>:<fpage>303</fpage>&#x02013;<lpage>11</lpage>. <pub-id pub-id-type="doi">10.1289/ehp.1205879</pub-id><pub-id pub-id-type="pmid">23249866</pub-id></citation></ref>
<ref id="B16">
<label>16.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Guyton</surname> <given-names>KZ</given-names></name> <name><surname>Hogan</surname> <given-names>KA</given-names></name> <name><surname>Scott</surname> <given-names>CS</given-names></name> <name><surname>Cooper</surname> <given-names>GS</given-names></name> <name><surname>Bale</surname> <given-names>AS</given-names></name> <name><surname>Kopylev</surname> <given-names>L</given-names></name> <etal/></person-group>. <article-title>Human health effects of tetrachloroethylene: key findings and scientific issues</article-title>. <source>Environ Health Perspect.</source> (<year>2014</year>) <volume>122</volume>:<fpage>325</fpage>&#x02013;<lpage>34</lpage>. <pub-id pub-id-type="doi">10.1289/ehp.1307359</pub-id><pub-id pub-id-type="pmid">24531164</pub-id></citation></ref>
<ref id="B17">
<label>17.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Vlaanderen</surname> <given-names>J</given-names></name> <name><surname>Straif</surname> <given-names>K</given-names></name> <name><surname>Ruder</surname> <given-names>A</given-names></name> <name><surname>Blair</surname> <given-names>A</given-names></name> <name><surname>Hansen</surname> <given-names>J</given-names></name> <name><surname>Lynge</surname> <given-names>E</given-names></name> <etal/></person-group>. <article-title>Tetrachloroethylene exposure and bladder cancer risk: a meta-analysis of dry-cleaning-worker studies</article-title>. <source>Environ Health Perspect.</source> (<year>2014</year>) <volume>122</volume>:<fpage>661</fpage>&#x02013;<lpage>6</lpage>. <pub-id pub-id-type="doi">10.1289/ehp.1307055</pub-id><pub-id pub-id-type="pmid">24659585</pub-id></citation></ref>
<ref id="B18">
<label>18.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Vlaanderen</surname> <given-names>J</given-names></name> <name><surname>Straif</surname> <given-names>K</given-names></name> <name><surname>Pukkala</surname> <given-names>E</given-names></name> <name><surname>Kauppinen</surname> <given-names>T</given-names></name> <name><surname>Kyyronen</surname> <given-names>P</given-names></name> <name><surname>Martinsen</surname> <given-names>JI</given-names></name> <etal/></person-group>. <article-title>Occupational exposure to trichloroethylene and perchloroethylene and the risk of lymphoma, liver, and kidney cancer in four Nordic countries</article-title>. <source>Occup Environ Med.</source> (<year>2013</year>) <volume>70</volume>:<fpage>393</fpage>&#x02013;<lpage>401</lpage>. <pub-id pub-id-type="doi">10.1136/oemed-2012-101188</pub-id><pub-id pub-id-type="pmid">23447073</pub-id></citation></ref>
<ref id="B19">
<label>19.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>NIOSH</collab></person-group>. <source>Tetrachloroethylene</source> (<year>2018</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www.cdc.gov/niosh/npg/npgd0599.html">https://www.cdc.gov/niosh/npg/npgd0599.html</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B20">
<label>20.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>IARC</collab></person-group>. <source>IARC Monographs on the Evaluation of Carcinogenic Risks to Humans; Dry Cleaning, Some Chlorinated Solvents and Other Industrial Chemicals (No. 63)</source>. <publisher-name>International Agency for Research on Cancer</publisher-name> (<year>1995</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://publications.iarc.fr/Book-And-Report-Series/Iarc-Monographs-On-The-Identification-Of-Carcinogenic-Hazards-To-Humans/Dry-Cleaning-Some-Chlorinated-Solvents-And-Other-Industrial-Chemicals-1995">https://publications.iarc.fr/Book-And-Report-Series/Iarc-Monographs-On-The-Identification-Of-Carcinogenic-Hazards-To-Humans/Dry-Cleaning-Some-Chlorinated-Solvents-And-Other-Industrial-Chemicals-1995</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B21">
<label>21.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Echeverria</surname> <given-names>D</given-names></name> <name><surname>White</surname> <given-names>R</given-names></name> <name><surname>Sampaio</surname> <given-names>C</given-names></name></person-group>. <article-title>A behavioral evaluation of PCE exposure in patients and dry cleaners: a possible relationship between clinical and preclinical effects</article-title>. <source>J Occup Environ Med.</source> (<year>1995</year>) <volume>37</volume>:<fpage>667</fpage>&#x02013;<lpage>80</lpage>. <pub-id pub-id-type="doi">10.1097/00043764-199506000-00008</pub-id><pub-id pub-id-type="pmid">7670913</pub-id></citation></ref>
<ref id="B22">
<label>22.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Seeber</surname> <given-names>A</given-names></name></person-group>. <article-title>Neurobehavioral toxicity of long-term exposure to tetrachloroethylene</article-title>. <source>Neurotoxicol Teratol.</source> (<year>1989</year>) <volume>11</volume>:<fpage>579</fpage>&#x02013;<lpage>83</lpage>. <pub-id pub-id-type="doi">10.1016/0892-0362(89)90041-X</pub-id><pub-id pub-id-type="pmid">2626148</pub-id></citation></ref>
<ref id="B23">
<label>23.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ferroni</surname> <given-names>C</given-names></name> <name><surname>Selis</surname> <given-names>L</given-names></name> <name><surname>Mutti</surname> <given-names>A</given-names></name> <name><surname>Folli</surname> <given-names>D</given-names></name> <name><surname>Bergamaschi</surname> <given-names>E</given-names></name> <name><surname>Franchini</surname> <given-names>I</given-names></name></person-group>. <article-title>Neurobehavioral and neuroendocrine effects of occupational exposure to perchloroethylene</article-title>. <source>Neurotoxicology.</source> (<year>1992</year>) <volume>13</volume>:<fpage>243</fpage>. <pub-id pub-id-type="pmid">1508425</pub-id></citation></ref>
<ref id="B24">
<label>24.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Spinatonda</surname> <given-names>G</given-names></name> <name><surname>Colombo</surname> <given-names>R</given-names></name> <name><surname>Capodaglio</surname> <given-names>EM</given-names></name> <name><surname>Imbriani</surname> <given-names>M</given-names></name> <name><surname>Pasetti</surname> <given-names>C</given-names></name> <name><surname>Minuco</surname> <given-names>G</given-names></name> <etal/></person-group>. <article-title>Processes of speech production: application in a group of subjects chronically exposed to organic solvents (II)</article-title>. <source>Giorn Ital Med Lavoro Ergonomia.</source> (<year>1997</year>) <volume>19</volume>:<fpage>85</fpage>.</citation></ref>
<ref id="B25">
<label>25.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Altmann</surname> <given-names>L</given-names></name> <name><surname>Neuhann</surname> <given-names>HF</given-names></name> <name><surname>Kramer</surname> <given-names>U</given-names></name> <name><surname>Witten</surname> <given-names>J</given-names></name> <name><surname>Jermann</surname> <given-names>E</given-names></name></person-group>. <article-title>Neurobehavioral and neurophysiological outcome of chronic low-level tetrachloroethene exposure measured in neighborhoods of dry cleaning shops</article-title>. <source>Environ Res.</source> (<year>1995</year>) <volume>69</volume>:<fpage>83</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1006/enrs.1995.1028</pub-id><pub-id pub-id-type="pmid">8608774</pub-id></citation></ref>
<ref id="B26">
<label>26.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Janulewicz</surname> <given-names>PA</given-names></name> <name><surname>White</surname> <given-names>RF</given-names></name> <name><surname>Martin</surname> <given-names>BM</given-names></name> <name><surname>Winter</surname> <given-names>MR</given-names></name> <name><surname>Weinberg</surname> <given-names>JM</given-names></name> <name><surname>Vieira</surname> <given-names>V</given-names></name> <etal/></person-group>. <article-title>Adult neuropsychological performance following prenatal and early postnatal exposure to tetrachloroethylene (PCE)-contaminated drinking water</article-title>. <source>Neurotoxicol Teratol.</source> (<year>2012</year>) <volume>34</volume>:<fpage>350</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1016/j.ntt.2012.04.001</pub-id><pub-id pub-id-type="pmid">22522125</pub-id></citation></ref>
<ref id="B27">
<label>27.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Aschengrau</surname> <given-names>A</given-names></name> <name><surname>Winter</surname> <given-names>MR</given-names></name> <name><surname>Gallagher</surname> <given-names>LG</given-names></name> <name><surname>Vieira</surname> <given-names>VM</given-names></name> <name><surname>Butler</surname> <given-names>LJ</given-names></name> <name><surname>Fabian</surname> <given-names>MP</given-names></name> <etal/></person-group>. <article-title>Reproductive and developmental health effects of prenatal exposure to tetrachloroethylene-contaminated drinking water</article-title>. <source>Environ Sci Process Impacts.</source> (<year>2020</year>) <volume>22</volume>:<fpage>555</fpage>&#x02013;<lpage>66</lpage>. <pub-id pub-id-type="doi">10.1039/C9EM00590K</pub-id><pub-id pub-id-type="pmid">32051987</pub-id></citation></ref>
<ref id="B28">
<label>28.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wesselink</surname> <given-names>AK</given-names></name> <name><surname>Hatch</surname> <given-names>EE</given-names></name> <name><surname>Wise</surname> <given-names>LA</given-names></name> <name><surname>Rothman</surname> <given-names>KJ</given-names></name> <name><surname>Vieira</surname> <given-names>VM</given-names></name> <name><surname>Aschengrau</surname> <given-names>A</given-names></name></person-group>. <article-title>Exposure to tetrachloroethylene-contaminated drinking water and time to pregnancy</article-title>. <source>Environ Res.</source> (<year>2018</year>) <volume>167</volume>:<fpage>136</fpage>&#x02013;<lpage>43</lpage>. <pub-id pub-id-type="doi">10.1016/j.envres.2018.07.012</pub-id><pub-id pub-id-type="pmid">30014895</pub-id></citation></ref>
<ref id="B29">
<label>29.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Aschengrau</surname> <given-names>A</given-names></name> <name><surname>Weinberg</surname> <given-names>JM</given-names></name> <name><surname>Janulewicz</surname> <given-names>PA</given-names></name> <name><surname>Gallagher</surname> <given-names>LG</given-names></name> <name><surname>Winter</surname> <given-names>MR</given-names></name> <name><surname>Vieira</surname> <given-names>VM</given-names></name> <etal/></person-group>. <article-title>Prenatal exposure to tetrachloroethylene-contaminated drinking water and the risk of congenital anomalies: A retrospective cohort study</article-title>. <source>Environ Health Global Access Sci Source.</source> (<year>2009</year>) <volume>8</volume>:<fpage>44</fpage>. <pub-id pub-id-type="doi">10.1186/1476-069X-8-44</pub-id><pub-id pub-id-type="pmid">19778411</pub-id></citation></ref>
<ref id="B30">
<label>30.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Aschengrau</surname> <given-names>A</given-names></name> <name><surname>Weinberg</surname> <given-names>JM</given-names></name> <name><surname>Janulewicz</surname> <given-names>PA</given-names></name> <name><surname>Romano</surname> <given-names>ME</given-names></name> <name><surname>Gallagher</surname> <given-names>LG</given-names></name> <name><surname>Winter</surname> <given-names>MR</given-names></name> <etal/></person-group>. <article-title>Occurrence of mental illness following prenatal and early childhood exposure to tetrachloroethylene (PCE)-contaminated drinking water: a retrospective cohort study</article-title>. <source>Environ Health Global Access Sci Source.</source> (<year>2012</year>) <volume>11</volume>:<fpage>2</fpage>. <pub-id pub-id-type="doi">10.1186/1476-069X-11-2</pub-id><pub-id pub-id-type="pmid">32272944</pub-id></citation></ref>
<ref id="B31">
<label>31.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Aschengrau</surname> <given-names>A</given-names></name> <name><surname>Janulewicz</surname> <given-names>PA</given-names></name> <name><surname>White</surname> <given-names>RF</given-names></name> <name><surname>Vieira</surname> <given-names>VM</given-names></name> <name><surname>Gallagher</surname> <given-names>LG</given-names></name> <name><surname>Getz</surname> <given-names>KD</given-names></name> <etal/></person-group>. <article-title>Long-term neurotoxic effects of early-life exposure to Tetrachloroethylene-contaminated drinking water</article-title>. <source>Ann Global Health.</source> (<year>2016</year>) <volume>82</volume>:<fpage>169</fpage>&#x02013;<lpage>79</lpage>. <pub-id pub-id-type="doi">10.1016/j.aogh.2016.01.013</pub-id><pub-id pub-id-type="pmid">27325074</pub-id></citation></ref>
<ref id="B32">
<label>32.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Aschengrau</surname> <given-names>A</given-names></name> <name><surname>Weinberg</surname> <given-names>JM</given-names></name> <name><surname>Janulewicz</surname> <given-names>PA</given-names></name> <name><surname>Romano</surname> <given-names>ME</given-names></name> <name><surname>Gallagher</surname> <given-names>LG</given-names></name> <name><surname>Winter</surname> <given-names>MR</given-names></name> <etal/></person-group>. <article-title>Affinity for risky behaviors following prenatal and early childhood exposure to tetrachloroethylene (PCE)-contaminated drinking water: a retrospective cohort study</article-title>. <source>Environ Health Global Access Sci Source.</source> (<year>2011</year>) <volume>10</volume>:<fpage>102</fpage>. <pub-id pub-id-type="doi">10.1186/1476-069X-10-102</pub-id><pub-id pub-id-type="pmid">22136431</pub-id></citation></ref>
<ref id="B33">
<label>33.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Getz</surname> <given-names>KD</given-names></name> <name><surname>Janulewicz</surname> <given-names>PA</given-names></name> <name><surname>Rowe</surname> <given-names>S</given-names></name> <name><surname>Janice</surname> <given-names>M</given-names></name> <name><surname>Weinberg Winter</surname> <given-names>MR</given-names></name> <name><surname>Martin</surname> <given-names>BR</given-names></name> <etal/></person-group>. <article-title>Prenatal and early childhood exposure to tetrachloroethylene and adult vision</article-title>. <source>Environ Health Perspect.</source> (<year>2012</year>) <volume>120</volume>:<fpage>1327</fpage>&#x02013;<lpage>32</lpage>. <pub-id pub-id-type="doi">10.1289/ehp.1103996</pub-id><pub-id pub-id-type="pmid">22784657</pub-id></citation></ref>
<ref id="B34">
<label>34.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Aschengrau</surname> <given-names>A</given-names></name> <name><surname>Winter</surname> <given-names>MR</given-names></name> <name><surname>Vieira</surname> <given-names>VM</given-names></name> <name><surname>Webster</surname> <given-names>TF</given-names></name> <name><surname>Janulewicz</surname> <given-names>PA</given-names></name> <name><surname>Gallagher</surname> <given-names>LG</given-names></name> <etal/></person-group>. <article-title>Long-term health effects of early life exposure to tetrachloroethylene (PCE)-contaminated drinking water: a retrospective cohort study</article-title>. <source>Environ Health.</source> (<year>2015</year>) <volume>14</volume>:<fpage>36</fpage>. <pub-id pub-id-type="doi">10.1186/s12940-015-0021-z</pub-id><pub-id pub-id-type="pmid">25889838</pub-id></citation></ref>
<ref id="B35">
<label>35.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Vieira</surname> <given-names>V</given-names></name> <name><surname>Webster</surname> <given-names>T</given-names></name> <name><surname>Weinberg</surname> <given-names>J</given-names></name> <name><surname>Aschengrau</surname> <given-names>A</given-names></name></person-group>. <article-title>Spatial analysis of bladder, kidney, and pancreatic cancer on upper Cape Cod: an application of generalized additive models to case-control data</article-title>. <source>Environ Health Global Access Sci Source.</source> (<year>2009</year>) <volume>8</volume>:<fpage>3</fpage>. <pub-id pub-id-type="doi">10.1186/1476-069X-8-3</pub-id><pub-id pub-id-type="pmid">19208254</pub-id></citation></ref>
<ref id="B36">
<label>36.</label>
<citation citation-type="web"><person-group person-group-type="author"><name><surname>US</surname> <given-names>EPA</given-names></name></person-group>. <source>Draft Risk Evaluation for Perchloroethylene</source> (<year>2020</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www.epa.gov/assessing-and-managing-chemicals-under-tsca/draft-risk-evaluation-perchloroethylene&#x00023;findings">https://www.epa.gov/assessing-and-managing-chemicals-under-tsca/draft-risk-evaluation-perchloroethylene&#x00023;findings</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B37">
<label>37.</label>
<citation citation-type="web"><person-group person-group-type="author"><name><surname>Whittaker</surname> <given-names>SG</given-names></name></person-group>. <source>The Aquatic Toxicity of Perchloroethylene Dry Cleaning Solvent</source> (Report no. LHWMP 0254). <publisher-loc>Seattle, WA</publisher-loc>: <publisher-name>Local Hazardous Waste Management Program in King County</publisher-name> (<year>2016</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://kingcountyhazwastewa.gov/-/media/lhwmp-documents/technical-reports/dry-cleaning-with-perc/rsh-aquatic-toxicity-of-perc-dry-cleaning-solvent.pdf">https://kingcountyhazwastewa.gov/-/media/lhwmp-documents/technical-reports/dry-cleaning-with-perc/rsh-aquatic-toxicity-of-perc-dry-cleaning-solvent.pdf</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B38">
<label>38.</label>
<citation citation-type="web"><person-group person-group-type="author"><name><surname>European</surname> <given-names>Commission</given-names></name></person-group>. <source>Study for the Strategy for a Non-toxic Environment of the 7th EAP.</source> <publisher-loc>Brussels</publisher-loc>: <publisher-name>European Commission</publisher-name> (<year>2017</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://ec.europa.eu/environment/chemicals/non-toxic/pdf/NTE%20main%20report%20final.pdf">https://ec.europa.eu/environment/chemicals/non-toxic/pdf/NTE%20main%20report%20final.pdf</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B39">
<label>39.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>OSHA</collab></person-group>. <source>Permissible Exposure Limits - Annotated Tables</source> (<year>2020</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www.osha.gov/dsg/annotated-pels/index.html">https://www.osha.gov/dsg/annotated-pels/index.html</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B40">
<label>40.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>CARB</collab></person-group>. <source>Non-toxic Dry Cleaning Incentive Program (AB998)</source> (<year>2017</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www.arb.ca.gov/toxics/dryclean/ab998.htm">https://www.arb.ca.gov/toxics/dryclean/ab998.htm</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B41">
<label>41.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>CARB</collab></person-group>. <source>Dry Cleaning Program</source> (<year>2017</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://ww3.arb.ca.gov/toxics/dryclean/dryclean.htm&#x00023;background">https://ww3.arb.ca.gov/toxics/dryclean/dryclean.htm&#x00023;background</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B42">
<label>42.</label>
<citation citation-type="web"><person-group person-group-type="author"><name><surname>US</surname> <given-names>EPA</given-names></name></person-group>. <source>Final Amendments to Air Toxics Standards for Perchloroethylene Dry Cleaners - Fact Sheet</source> (<year>2006</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www.epa.gov/sites/production/files/2015-06/documents/fact_sheet_dry_cleaning_july2006.pdf">https://www.epa.gov/sites/production/files/2015-06/documents/fact_sheet_dry_cleaning_july2006.pdf</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B43">
<label>43.</label>
<citation citation-type="web"><person-group person-group-type="author"><name><surname>US</surname> <given-names>EPA</given-names></name></person-group>. <source>Risk Evaluation for Perchloroethylene</source> (<year>2019</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www.epa.gov/assessing-and-managing-chemicals-under-tsca/risk-evaluation-perchloroethylene">https://www.epa.gov/assessing-and-managing-chemicals-under-tsca/risk-evaluation-perchloroethylene</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B44">
<label>44.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>ECSA</collab></person-group>. <source>PER in Dry-Cleaning (Including National Issues)</source> (<year>2013</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www.chlorinated-solvents.eu/regulatory/per-in-dry-cleaning/">https://www.chlorinated-solvents.eu/regulatory/per-in-dry-cleaning/</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B45">
<label>45.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>TURI</collab></person-group>. <source>Assessment of Alternatives to Perchloroethylene for the Dry Cleaning Industry</source> (Report no. 27). Toxics Use Reduction Institute (<year>2012</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www.turi.org/TURI_Publications/TURI_Methods_Policy_Reports/Assessment_of_Alternatives_to_Perchloroethylene_for_the_Dry_Cleaning_Industry._2012/2012_M_P_Report_27_Assessment_of_Safer_Alternatives_to_Perchloroethylene">https://www.turi.org/TURI_Publications/TURI_Methods_Policy_Reports/Assessment_of_Alternatives_to_Perchloroethylene_for_the_Dry_Cleaning_Industry._2012/2012_M_P_Report_27_Assessment_of_Safer_Alternatives_to_Perchloroethylene</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B46">
<label>46.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Troynikov</surname> <given-names>O</given-names></name> <name><surname>Watson</surname> <given-names>C</given-names></name> <name><surname>Jadhav</surname> <given-names>A</given-names></name> <name><surname>Nawaz</surname> <given-names>N</given-names></name> <name><surname>Kettlewell</surname> <given-names>R</given-names></name></person-group>. <article-title>Towards sustainable and safe apparel cleaning methods: a review</article-title>. <source>J Environ Manag.</source> (<year>2016</year>) <volume>182</volume>:<fpage>252</fpage>&#x02013;<lpage>64</lpage>. <pub-id pub-id-type="doi">10.1016/j.jenvman.2016.07.078</pub-id><pub-id pub-id-type="pmid">27486929</pub-id></citation></ref>
<ref id="B47">
<label>47.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>ATSDR</collab></person-group>. <source>Toxicological Profile for 1-Bromopropane.</source> <publisher-loc>Atlanta, GA</publisher-loc>: <publisher-name>Agency for Toxic Substances &#x00026; Disease Registry</publisher-name> (<year>2017</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www.atsdr.cdc.gov/toxprofiles/TP.asp?id=1471&#x00026;tid=285">https://www.atsdr.cdc.gov/toxprofiles/TP.asp?id=1471&#x00026;tid=285</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B48">
<label>48.</label>
<citation citation-type="journal"><person-group person-group-type="author"><collab>CDC</collab></person-group>. <article-title>Neurologic illness associated with occupational exposure to the solvent 1-bromopropane&#x02013;New Jersey and Pennsylvania, 2007-2008</article-title>. <source>Morbid Mortal Wkly Rep.</source> (<year>2008</year>) <volume>57</volume>:<fpage>1300</fpage>&#x02013;<lpage>2</lpage>.</citation>
</ref>
<ref id="B49">
<label>49.</label>
<citation citation-type="book"><person-group person-group-type="author"><collab>ACGIH</collab></person-group>. <source>2019 TLVs and BEIs: Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices.</source> <publisher-loc>Cincinnati, OH</publisher-loc>: <publisher-name>American Conference of Governmental Industrial Hygienists</publisher-name> (<year>2019</year>).</citation></ref>
<ref id="B50">
<label>50.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Blando</surname> <given-names>JD</given-names></name> <name><surname>Schill</surname> <given-names>DP</given-names></name> <name><surname>De La Cruz</surname> <given-names>MP</given-names></name> <name><surname>Zhang</surname> <given-names>L</given-names></name> <name><surname>Zhang</surname> <given-names>J</given-names></name></person-group>. <article-title>Preliminary study of propyl bromide exposure among New Jersey dry cleaners as a result of a pending ban on perchloroethylene</article-title>. <source>J Air Waste Manag Assoc.</source> (<year>2012</year>) <volume>60</volume>:<fpage>1049</fpage>&#x02013;<lpage>56</lpage>. <pub-id pub-id-type="doi">10.3155/1047-3289.60.9.1049</pub-id><pub-id pub-id-type="pmid">20863050</pub-id></citation></ref>
<ref id="B51">
<label>51.</label>
<citation citation-type="web"><person-group person-group-type="author"><name><surname>US</surname> <given-names>EPA</given-names></name></person-group>. <source>Risk Evaluation for 1-Bromopropane (1-BP)</source> (<year>2019</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www.epa.gov/assessing-and-managing-chemicals-under-tsca/risk-evaluation-1-bromopropane-1-bp">https://www.epa.gov/assessing-and-managing-chemicals-under-tsca/risk-evaluation-1-bromopropane-1-bp</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B52">
<label>52.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Genualdi</surname> <given-names>S</given-names></name> <name><surname>Harner</surname> <given-names>T</given-names></name> <name><surname>Cheng</surname> <given-names>Y</given-names></name> <name><surname>Macleod</surname> <given-names>M</given-names></name> <name><surname>Hansen</surname> <given-names>KM</given-names></name> <name><surname>van Egmond</surname> <given-names>R</given-names></name> <etal/></person-group>. <article-title>Global distribution of linear and cyclic volatile methyl siloxanes in air</article-title>. <source>Environ Sci Technol.</source> (<year>2011</year>) <volume>45</volume>:<fpage>3349</fpage>&#x02013;<lpage>54</lpage>. <pub-id pub-id-type="doi">10.1021/es200301j</pub-id><pub-id pub-id-type="pmid">21438524</pub-id></citation></ref>
<ref id="B53">
<label>53.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>ECCC</collab></person-group>. <source>Report of the Board of Review for Decamethylcyclopentasiloxane (siloxane D5)</source> (<year>2013</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www.ec.gc.ca/lcpe-cepa/default.asp?lang=En&#x00026;n=515887B7-1&#x00026;offset=3&#x00026;toc=show&#x00023;s2.1">https://www.ec.gc.ca/lcpe-cepa/default.asp?lang=En&#x00026;n=515887B7-1&#x00026;offset=3&#x00026;toc=show&#x00023;s2.1</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B54">
<label>54.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jean</surname> <given-names>PA</given-names></name> <name><surname>Sloter</surname> <given-names>ED</given-names></name> <name><surname>Plotzke</surname> <given-names>KP</given-names></name></person-group>. <article-title>Effects of chronic exposure to octamethylcyclotetrasiloxane and decamethylcyclopentasiloxane in the aging female Fischer 344 rat</article-title>. <source>Toxicol Lett.</source> (<year>2017</year>) <volume>279</volume>:<fpage>54</fpage>&#x02013;<lpage>74</lpage>. <pub-id pub-id-type="doi">10.1016/j.toxlet.2017.08.016</pub-id><pub-id pub-id-type="pmid">28842205</pub-id></citation></ref>
<ref id="B55">
<label>55.</label>
<citation citation-type="web"><person-group person-group-type="author"><name><surname>US</surname> <given-names>EPA</given-names></name></person-group>. <source>Siloxane D5 in Drycleaning Applications</source> <publisher-name>United States Environmental Protection Agency</publisher-name> (<year>2009</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://nepis.epa.gov/Exe/ZyNET.exe/P1004S1S.TXT?ZyActionD=ZyDocument&#x00026;Client=EPA&#x00026;Index=2006&#x0002B;Thru&#x0002B;2010&#x00026;Docs=&#x00026;Query=&#x00026;Time=&#x00026;EndTime=&#x00026;SearchMethod=1&#x00026;TocRestrict=n&#x00026;Toc=&#x00026;TocEntry=&#x00026;QField=&#x00026;QFieldYear=&#x00026;QFieldMonth=&#x00026;QFieldDay=&#x00026;IntQFieldOp=0&#x00026;ExtQFieldOp=0&#x00026;XmlQuery=&#x00026;File=D%3A%5Czyfiles%5CIndex%20Data%5C06thru10%5CTxt%5C00000009%5CP1004S1S.txt&#x00026;User=ANONYMOUS&#x00026;Password=anonymous&#x00026;SortMethod=h%7C-&#x00026;MaximumDocuments=1&#x00026;FuzzyDegree=0&#x00026;ImageQuality=r75g8/r75g8/x150y150g16/i425&#x00026;Display=hpfr&#x00026;DefSeekPage=x&#x00026;SearchBack=ZyActionL&#x00026;Back=ZyActionS&#x00026;BackDesc=Results%20page&#x00026;MaximumPages=1&#x00026;ZyEntry=1&#x00026;SeekPage=x&#x00026;ZyPURL">https://nepis.epa.gov/Exe/ZyNET.exe/P1004S1S.TXT?ZyActionD=ZyDocument&#x00026;Client=EPA&#x00026;Index=2006&#x0002B;Thru&#x0002B;2010&#x00026;Docs=&#x00026;Query=&#x00026;Time=&#x00026;EndTime=&#x00026;SearchMethod=1&#x00026;TocRestrict=n&#x00026;Toc=&#x00026;TocEntry=&#x00026;QField=&#x00026;QFieldYear=&#x00026;QFieldMonth=&#x00026;QFieldDay=&#x00026;IntQFieldOp=0&#x00026;ExtQFieldOp=0&#x00026;XmlQuery=&#x00026;File=D%3A%5Czyfiles%5CIndex%20Data%5C06thru10%5CTxt%5C00000009%5CP1004S1S.txt&#x00026;User=ANONYMOUS&#x00026;Password=anonymous&#x00026;SortMethod=h%7C-&#x00026;MaximumDocuments=1&#x00026;FuzzyDegree=0&#x00026;ImageQuality=r75g8/r75g8/x150y150g16/i425&#x00026;Display=hpfr&#x00026;DefSeekPage=x&#x00026;SearchBack=ZyActionL&#x00026;Back=ZyActionS&#x00026;BackDesc=Results%20page&#x00026;MaximumPages=1&#x00026;ZyEntry=1&#x00026;SeekPage=x&#x00026;ZyPURL</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B56">
<label>56.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>Shin-Etsu</collab></person-group>. <source>Safety Data Sheet for Modified Silicone Fluids (GEC-5)</source> <publisher-name>Shin-Etsu Silicones of America, Inc</publisher-name>. (<year>2014</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www1.nyc.gov/assets/dep/downloads/pdf/air/non-perc-shin-etsu-silicones-of-america-gec-5-green-earth-cleaning-safety-sheet.pdf">https://www1.nyc.gov/assets/dep/downloads/pdf/air/non-perc-shin-etsu-silicones-of-america-gec-5-green-earth-cleaning-safety-sheet.pdf</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B57">
<label>57.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>Toxnot</collab></person-group>. <source>Toxnot Profile for Cyclopentasiloxane, Decamethyl</source> (<year>2020</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://toxnot.com/Substances/SubstanceDetail/4bfd3db3-b856-4325-bf95-ffcca0743107/541-02-6">https://toxnot.com/Substances/SubstanceDetail/4bfd3db3-b856-4325-bf95-ffcca0743107/541-02-6</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B58">
<label>58.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>OEHHA</collab></person-group>. <source>Propylene Glycol Mono-t-butyl ether</source> (<year>2015</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://oehha.ca.gov/chemicals/propylene-glycol-mono-t-butyl-ether">https://oehha.ca.gov/chemicals/propylene-glycol-mono-t-butyl-ether</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B59">
<label>59.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>Kreussler</collab></person-group>. <source>Kreussler Textile Care: System K4</source> (<year>2011</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="http://en.kreussler-chemie.com/customers/textile_cleaners/systemk4/products_and_procedures.html">http://en.kreussler-chemie.com/customers/textile_cleaners/systemk4/products_and_procedures.html</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B60">
<label>60.</label>
<citation citation-type="book"><person-group person-group-type="author"><collab>Kreussler</collab></person-group>. <source>What Landlords Need to Know About SystemK4.</source> <publisher-loc>Tampa, FL</publisher-loc>: <publisher-name>Kreussler</publisher-name> (<year>2010</year>).</citation></ref>
<ref id="B61">
<label>61.</label>
<citation citation-type="book"><person-group person-group-type="author"><collab>NYSDEC</collab></person-group>. <source>DraftMemorandum: Toxic Contaminant Review of the Butylal Dry-Cleaning Solvent (Currently Marketed Under the Trade Name SolvonK4 by Kreussler, Inc</source>.). <publisher-loc>New York, NY</publisher-loc>: <publisher-name>New York State Department of Environmental Conservation</publisher-name> (<year>2011</year>).</citation></ref>
<ref id="B62">
<label>62.</label>
<citation citation-type="web"><person-group person-group-type="author"><name><surname>Whittaker</surname> <given-names>SG</given-names></name></person-group>. <source>Evaluation of Solvon K4<sup>TM</sup> in an Acute Fish Toxicity Test</source> (Report no. LHWMP 0185). <publisher-loc>Seattle, WA</publisher-loc>: <publisher-name>Local Hazardous Waste Management Program in King County</publisher-name> (<year>2013</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://kingcountyhazwastewa.gov/-/media/lhwmp-documents/technical-reports/alternatives-to-dry-cleaning-with-perc/rsh-evaluation-of-solvon-k4-in-acute-fish-toxicity-test.pdf">https://kingcountyhazwastewa.gov/-/media/lhwmp-documents/technical-reports/alternatives-to-dry-cleaning-with-perc/rsh-evaluation-of-solvon-k4-in-acute-fish-toxicity-test.pdf</ext-link> (accessed November 20, 2020).<pub-id pub-id-type="pmid">29226368</pub-id></citation></ref>
<ref id="B63">
<label>63.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>Kreussler</collab></person-group>. <source>Safety Data Sheet for Solvon K4</source> (<year>2018</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="http://www.dec.ny.gov/docs/air_pdf/sdssolvonk4.pdf">http://www.dec.ny.gov/docs/air_pdf/sdssolvonk4.pdf</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B64">
<label>64.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ceballos</surname> <given-names>DM</given-names></name> <name><surname>Whittaker</surname> <given-names>SG</given-names></name> <name><surname>Lee</surname> <given-names>EG</given-names></name> <name><surname>Roberts</surname> <given-names>J</given-names></name> <name><surname>Streicher</surname> <given-names>R</given-names></name> <name><surname>Nourian</surname> <given-names>F</given-names></name> <etal/></person-group>. <article-title>Occupational exposures to new dry cleaning solvents: high-flashpoint hydrocarbons and butylal</article-title>. <source>J Occup Environ Hyg.</source> (<year>2016</year>) <volume>13</volume>:<fpage>759</fpage>&#x02013;<lpage>69</lpage>. <pub-id pub-id-type="doi">10.1080/15459624.2016.1177648</pub-id><pub-id pub-id-type="pmid">27105306</pub-id></citation></ref>
<ref id="B65">
<label>65.</label>
<citation citation-type="book"><person-group person-group-type="author"><collab>NIOSH</collab></person-group>. <source>Evaluation of Occupational Exposures at Drycleaning Shops That Use SolvonK4 and DF-2000 (No. HHE Report 2012-0084-3227).</source> <publisher-loc>Cincinnati, OH</publisher-loc>: <publisher-name>U.S. Department of Health and Human Services, National Institute for Occupational Safety and Health</publisher-name> (<year>2015</year>).</citation></ref>
<ref id="B66">
<label>66.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>ECHA</collab></person-group>. <source>C&#x00026;L Inventory Database</source> (<year>2020</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://echa.europa.eu/search?p_p_id=echasearch_WAR_echaportlet&#x00026;p_p_lifecycle=0&#x00026;p_p_state=normal&#x00026;p_p_mode=view&#x00026;p_p_col_id=column-1&#x00026;p_p_col_count=1">https://echa.europa.eu/search?p_p_id=echasearch_WAR_echaportlet&#x00026;p_p_lifecycle=0&#x00026;p_p_state=normal&#x00026;p_p_mode=view&#x00026;p_p_col_id=column-1&#x00026;p_p_col_count=1</ext-link></citation></ref>
<ref id="B67">
<label>67.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mckee</surname> <given-names>RH</given-names></name> <name><surname>Adenuga</surname> <given-names>MD</given-names></name> <name><surname>Carrillo</surname> <given-names>JC</given-names></name></person-group>. <article-title>Characterization of the toxicological hazards of hydrocarbon solvents</article-title>. <source>Crit Rev Toxicol.</source> (<year>2015</year>) <volume>45</volume>:<fpage>273</fpage>&#x02013;<lpage>365</lpage>. <pub-id pub-id-type="doi">10.3109/10408444.2015.1016216</pub-id><pub-id pub-id-type="pmid">25868376</pub-id></citation></ref>
<ref id="B68">
<label>68.</label>
<citation citation-type="web"><person-group person-group-type="author"><name><surname>Whittaker</surname> <given-names>SG</given-names></name> <name><surname>Shaffer</surname> <given-names>RM</given-names></name></person-group>. <source>Dry Cleaning With High-Flashpoint Hydrocarbon Solvents</source> (Report no. LHWMP 0275). <publisher-loc>Seattle, WA</publisher-loc>: <publisher-name>Hazardous Waste Management Program in King County</publisher-name> (<year>2018</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://kingcountyhazwastewa.gov/-/media/lhwmp-documents/technical-reports/alternatives-to-dry-cleaning-with-perc/rsh-dry-cleaning-with-high-flashpoint-hydrocarbon-solvents.pdf">https://kingcountyhazwastewa.gov/-/media/lhwmp-documents/technical-reports/alternatives-to-dry-cleaning-with-perc/rsh-dry-cleaning-with-high-flashpoint-hydrocarbon-solvents.pdf</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B69">
<label>69.</label>
<citation citation-type="web"><person-group person-group-type="author"><name><surname>Whittaker</surname> <given-names>SG</given-names></name></person-group>. <source>Evaluation of DF2000<sup>TM</sup> Dry Cleaning Solvent in an Acute Fish Toxicity Test</source> (Report no. LHWMP 0203). <publisher-loc>Seattle, WA</publisher-loc>: <publisher-name>Local Hazardous Waste Management Program in King County</publisher-name> (<year>2014</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://kingcountyhazwastewa.gov/-/media/lhwmp-documents/technical-reports/alternatives-to-dry-cleaning-with-perc/rsh-evaluation-of-df2000-dry-cleaning-solvent-in-acute-fish-toxcity-test.pdf">https://kingcountyhazwastewa.gov/-/media/lhwmp-documents/technical-reports/alternatives-to-dry-cleaning-with-perc/rsh-evaluation-of-df2000-dry-cleaning-solvent-in-acute-fish-toxcity-test.pdf</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B70">
<label>70.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>IFA</collab></person-group>. <source>GESTIS International Limit Values</source> (<year>2020</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://limitvalue.ifa.dguv.de/WebForm_ueliste2.aspx">https://limitvalue.ifa.dguv.de/WebForm_ueliste2.aspx</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B71">
<label>71.</label>
<citation citation-type="web"><person-group person-group-type="author"><name><surname>Whittaker</surname> <given-names>SG</given-names></name> <name><surname>Fellows</surname> <given-names>KM</given-names></name> <name><surname>Pedersen</surname> <given-names>A</given-names></name></person-group>. <source>Converting PERC Dry Cleaners to Professional Wet Cleaning: A Pilot Program</source> (Report no. LHWMP 0337). <publisher-loc>Seattle, WA</publisher-loc>: <publisher-name>Hazardous Waste Management Program in King County</publisher-name> (<year>2020</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://kingcountyhazwastewa.gov/-/media/lhwmp-documents/technical-reports/professional-wet-cleaning/rsh-converting-dry-cleaners-to-wet-cleaning-pilot.pdf">https://kingcountyhazwastewa.gov/-/media/lhwmp-documents/technical-reports/professional-wet-cleaning/rsh-converting-dry-cleaners-to-wet-cleaning-pilot.pdf</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B72">
<label>72.</label>
<citation citation-type="web"><person-group person-group-type="author"><name><surname>Whittaker</surname> <given-names>SG</given-names></name> <name><surname>Taylor</surname> <given-names>J</given-names></name> <name><surname>Van Hooser</surname> <given-names>LM</given-names></name></person-group>. <source>Characterizing Alternative Solvent Dry Cleaning Processes</source> (Report no. LHWMP 0155). <publisher-loc>Seattle, WA</publisher-loc>: <publisher-name>Local Hazardous Waste Management Program in King County</publisher-name> (<year>2013</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://kingcountyhazwastewa.gov/-/media/lhwmp-documents/technical-reports/alternatives-to-dry-cleaning-with-perc/rsh-characterizing-alternative-solvent-dry-cleaning-processes.pdf">https://kingcountyhazwastewa.gov/-/media/lhwmp-documents/technical-reports/alternatives-to-dry-cleaning-with-perc/rsh-characterizing-alternative-solvent-dry-cleaning-processes.pdf</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B73">
<label>73.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Whittaker</surname> <given-names>SG</given-names></name> <name><surname>Taylor</surname> <given-names>J</given-names></name> <name><surname>Van Hooser</surname> <given-names>LM</given-names></name></person-group>. <article-title>Characterization of &#x0201C;hydrocarbon&#x0201D; dry cleaning in King County, Washington</article-title>. <source>J Environ Health.</source> (<year>2015</year>) <volume>78</volume>:<fpage>8</fpage>&#x02013;<lpage>13</lpage>. <pub-id pub-id-type="pmid">26502560</pub-id></citation></ref>
<ref id="B74">
<label>74.</label>
<citation citation-type="web"><person-group person-group-type="author"><name><surname>Whittaker</surname> <given-names>SG</given-names></name> <name><surname>Shaffer</surname> <given-names>RM</given-names></name></person-group>. <source>Hazard Evaluation of Products Used in Fabric Cleaning</source> (Report no. LHWMP 0335). <publisher-loc>Seattle, WA</publisher-loc>: <publisher-name>Hazardous Waste Management Program in King County</publisher-name> (<year>2019</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://kingcountyhazwastewa.gov/-/media/lhwmp-documents/technical-reports/professional-wet-cleaning/rsh-hazard-evaluation-of-products--used-in-fabric-cleaning.pdf">https://kingcountyhazwastewa.gov/-/media/lhwmp-documents/technical-reports/professional-wet-cleaning/rsh-hazard-evaluation-of-products&#x02013;used-in-fabric-cleaning.pdf</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B75">
<label>75.</label>
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Gottlieb</surname> <given-names>R</given-names></name></person-group>. <article-title>Dry cleaning&#x00027;s dilemma and opportunity: Overcoming chemical dependencies and creating a community of interests</article-title>. In: <person-group person-group-type="editor"><name><surname>Gottlieb</surname> <given-names>R</given-names></name></person-group>, editor. <source>Environmentalism Unbound.</source> <publisher-loc>Cambridge, MA</publisher-loc>: <publisher-name>Massachusetts Institute of Technology</publisher-name> (<year>2001</year>). p. <fpage>101</fpage>&#x02013;<lpage>339</lpage>.</citation></ref>
<ref id="B76">
<label>76.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Onasch</surname> <given-names>J</given-names></name></person-group>. <article-title>A feasibility and cost comparison of perchloroethylene dry cleaning to professional wet cleaning: Case study of Silver Hanger Cleaners, Bellingham, Massachusetts</article-title>. <source>J Clean Prod.</source> (<year>2011</year>) <volume>19</volume>:<fpage>477</fpage>&#x02013;<lpage>82</lpage>. <pub-id pub-id-type="doi">10.1016/j.jclepro.2010.07.015</pub-id></citation></ref>
<ref id="B77">
<label>77.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Onasch</surname> <given-names>J</given-names></name> <name><surname>Jacobs</surname> <given-names>M</given-names></name> <name><surname>Biddle</surname> <given-names>E</given-names></name></person-group>. <article-title>From perchloroethylene dry cleaning to professional wet cleaning: making the health and business case for reducing toxics</article-title>. <source>J Environ Health.</source> (<year>2017</year>) <volume>79</volume>:<fpage>E1</fpage>&#x02212;<lpage>7</lpage>.</citation></ref>
<ref id="B78">
<label>78.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sinsheimer</surname> <given-names>P</given-names></name> <name><surname>Grout</surname> <given-names>C</given-names></name> <name><surname>Namkoong</surname> <given-names>A</given-names></name> <name><surname>Gottlieb</surname> <given-names>R</given-names></name></person-group>. <article-title>The viability of professional wet cleaning as a pollution prevention alternative to perchloroethylene dry cleaning</article-title>. <source>J Air Waste Manag Assoc.</source> (<year>2007</year>) <volume>57</volume>:<fpage>172</fpage>&#x02013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1080/10473289.2007.10465320</pub-id><pub-id pub-id-type="pmid">17355078</pub-id></citation></ref>
<ref id="B79">
<label>79.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>TURI</collab></person-group>. <source>Dry Cleaning</source> (<year>2019</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="http://www.turi.org/Our_Work/Business/Small_Businesses/Dry_Cleaning">http://www.turi.org/Our_Work/Business/Small_Businesses/Dry_Cleaning</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B80">
<label>80.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>City of Minneapolis</collab></person-group>. <source>After Helping Dry Cleaners Switch to Cleaner Processes, Minneapolis Bans Hazardous &#x02018;Perc&#x02019;</source> (<year>2019</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="http://www.ci.minneapolis.mn.us/news/WCMSP-220375">http://www.ci.minneapolis.mn.us/news/WCMSP-220375</ext-link> (accessed November 20, 2020).</citation>
</ref>
<ref id="B81">
<label>81.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>City of Philadelphia</collab></person-group>. <source>Air Management Regulation XIV Control of Emissions From Dry Cleaning Facilities</source> (<year>2010</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www.phila.gov/media/20181031151836/Control-of-Emissions-from-Dry-Cleaning-acilities-Reg14.pdf">https://www.phila.gov/media/20181031151836/Control-of-Emissions-from-Dry-Cleaning-acilities-Reg14.pdf</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B82">
<label>82.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>NYCDEP</collab></person-group>. <source>Requiring Posting of Notices at Dry Cleaning Facilities</source> (<year>2012</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://rules.cityofnewyork.us/content/requiring-posting-notices-dry-cleaning-facilities-0">https://rules.cityofnewyork.us/content/requiring-posting-notices-dry-cleaning-facilities-0</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B83">
<label>83.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Whittaker</surname> <given-names>SG</given-names></name> <name><surname>Johanson</surname> <given-names>CA</given-names></name></person-group>. <article-title>A health and environmental profile of the dry cleaning industry in King County, Washington</article-title>. <source>J Environ Health.</source> (<year>2013</year>) <volume>75</volume>:<fpage>14</fpage>&#x02013;<lpage>22</lpage>. <pub-id pub-id-type="pmid">23858662</pub-id></citation></ref>
<ref id="B84">
<label>84.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>NIOSH</collab></person-group>. <source>Health Hazard Evaluation Report: Evaluation of Occupational Exposures at a Drycleaning Shop Using SolvonK4</source> HETA 2012-0084-3227. National Institute for Occupational Safety and Health (<year>2015</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://stacks.cdc.gov/view/cdc/27676">https://stacks.cdc.gov/view/cdc/27676</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B85">
<label>85.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>NYSDEC</collab></person-group>. <source>Approved Alternative Solvents for Dry Cleaning</source> (<year>2020</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www.dec.ny.gov/chemical/72273.html">https://www.dec.ny.gov/chemical/72273.html</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B86">
<label>86.</label>
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Chevron</surname> <given-names>Phillips</given-names></name></person-group>. <source>Material Safety Data Sheet for ECOSOLV&#x000AE; Dry Cleaning Fluid</source> Revision No. 8.01. <publisher-loc>The Woodlands, TX</publisher-loc>: <publisher-name>Chevron Phillips Chemical Company LP</publisher-name> (<year>2008</year>).</citation></ref>
<ref id="B87">
<label>87.</label>
<citation citation-type="book"><person-group person-group-type="author"><collab>ExxonMobil</collab></person-group>. <source>Material Safety Data Sheet for DF-2000 Fluid</source> (No. 92842583). <publisher-loc>Houston, TX</publisher-loc>: <publisher-name>ExxonMobil Chemical Company</publisher-name> (<year>2001</year>).</citation></ref>
<ref id="B88">
<label>88.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>Streets</collab></person-group>. <source>Safety Data Sheet for PerSec</source> (<year>2016</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="http://www.tschoppsupply.com/wp/wp-content/uploads/2018/08/PerSec-GHS-SDS.pdf">http://www.tschoppsupply.com/wp/wp-content/uploads/2018/08/PerSec-GHS-SDS.pdf</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B89">
<label>89.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>Ecology</collab></person-group>. <source>Biological Testing Methods 80-12 - for the Designation of Dangerous Waste</source> (<year>2009</year>). <publisher-loc>Olympia, WA</publisher-loc>: <publisher-name>Washington State Department of Ecology</publisher-name>. Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://apps.ecology.wa.gov/publications/summarypages/8012.html">https://apps.ecology.wa.gov/publications/summarypages/8012.html</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B90">
<label>90.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>Ecology</collab></person-group>. <source>Chapter 173-303 WAC: Dangerous Waste Regulations</source> (No. 15-04-007). <publisher-loc>Olympia, WA</publisher-loc>: <publisher-name>Washington State Department of Ecology</publisher-name> (<year>2014</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://apps.leg.wa.gov/wac/default.aspx?cite=173-303">https://apps.leg.wa.gov/wac/default.aspx?cite=173-303</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B91">
<label>91.</label>
<citation citation-type="web"><person-group person-group-type="author"><name><surname>Whittaker</surname> <given-names>SG</given-names></name></person-group>. <source>Aquatic Toxicity of PERC Still Bottom Wastes: A Pilot Study</source> (Report no. LHWMP 0247). <publisher-loc>Seattle, WA</publisher-loc>: <publisher-name>Local Hazardous Waste Management Program in King County</publisher-name> (<year>2015</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://kingcountyhazwastewa.gov/-/media/lhwmp-documents/technical-reports/dry-cleaning-with-perc/rsh-aquatic-toxicity-of-perc-still-bottom-wastes-pilot-study.pdf">https://kingcountyhazwastewa.gov/-/media/lhwmp-documents/technical-reports/dry-cleaning-with-perc/rsh-aquatic-toxicity-of-perc-still-bottom-wastes-pilot-study.pdf</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B92">
<label>92.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>IBISWorld</collab></person-group>. <source>Industry Market Research, Reports, and Statistics</source>. (<year>2020</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www.ibisworld.com/default.aspx">https://www.ibisworld.com/default.aspx</ext-link> (accessed November 20, 2020).</citation></ref>
<ref id="B93">
<label>93.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>OSHA</collab></person-group>. <source>Step 7: Implement and Evaluate the Alternative</source>. (<year>2020</year>). Retrieved from: <ext-link ext-link-type="uri" xlink:href="https://www.osha.gov/dsg/safer_chemicals/step7_evaluate.html">https://www.osha.gov/dsg/safer_chemicals/step7_evaluate.html</ext-link> (accessed November 20, 2020).</citation></ref>
</ref-list>
<fn-group>
<fn fn-type="financial-disclosure"><p><bold>Funding.</bold> Part of DC&#x00027;s time writing this manuscript was supported by NIH/NIEHS grant number 2R25ES023635-04. The case study depicted in the manuscript and the time spent in this manuscript by SW, KF, and AE were funded by the Local Hazardous Waste fund, King County, Washington.</p>
</fn>
</fn-group>
</back>
</article>