<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="review-article" dtd-version="2.3" xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Physiol.</journal-id>
<journal-title>Frontiers in Physiology</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Physiol.</abbrev-journal-title>
<issn pub-type="epub">1664-042X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">886675</article-id>
<article-id pub-id-type="doi">10.3389/fphys.2022.886675</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Physiology</subject>
<subj-group>
<subject>Mini Review</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Image-Based Experimental Measurement Techniques to Characterize Velocity Fields in Blood Microflows</article-title>
<alt-title alt-title-type="left-running-head">Le and Fenech</alt-title>
<alt-title alt-title-type="right-running-head">Measurement Techniques for Blood Microflows</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Le</surname>
<given-names>Andy Vinh</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1515075/overview"/>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Fenech</surname>
<given-names>Marianne</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1429884/overview"/>
</contrib>
</contrib-group>
<aff id="aff1">
<sup>1</sup>
<institution>Department of Mechanical Engineering</institution>, <institution>University of Ottawa</institution>, <addr-line>Ottawa</addr-line>, <addr-line>ON</addr-line>, <country>Canada</country>
</aff>
<aff id="aff2">
<sup>2</sup>
<institution>Centre de Biochimie Structurale</institution>, <institution>CNRS UMR 5048&#x2014;INSERM UMR 1054</institution>, <institution>University of Montpellier</institution>, <addr-line>Montpellier</addr-line>, <country>France</country>
</aff>
<author-notes>
<fn fn-type="edited-by">
<p>
<bold>Edited by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/758910/overview">Stavroula Balabani</ext-link>, University College London, United Kingdom</p>
</fn>
<fn fn-type="edited-by">
<p>
<bold>Reviewed by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/533420/overview">Georgios C. Georgiou</ext-link>, University of Cyprus, Cyprus</p>
</fn>
<corresp id="c001">&#x2a;Correspondence: Marianne Fenech, <email>mfenech@uottawa.ca</email>
</corresp>
<fn fn-type="other">
<p>This article was submitted to Biophysics, a section of the journal Frontiers in Physiology</p>
</fn>
</author-notes>
<pub-date pub-type="epub">
<day>29</day>
<month>04</month>
<year>2022</year>
</pub-date>
<pub-date pub-type="collection">
<year>2022</year>
</pub-date>
<volume>13</volume>
<elocation-id>886675</elocation-id>
<history>
<date date-type="received">
<day>28</day>
<month>02</month>
<year>2022</year>
</date>
<date date-type="accepted">
<day>04</day>
<month>04</month>
<year>2022</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2022 Le and Fenech.</copyright-statement>
<copyright-year>2022</copyright-year>
<copyright-holder>Le and Fenech</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<p>Predicting blood microflow in both simple and complex geometries is challenging because of the composition and behavior of the blood at microscale. However, characterization of the velocity in microchannels is the key for gaining insights into cellular interactions at the microscale, mechanisms of diseases, and efficacy of therapeutic solutions. Image-based measurement techniques are a subset of methods for measuring the local flow velocity that typically utilize tracer particles for flow visualization. In the most basic form, a high-speed camera and microscope setup are the only requirements for data acquisition; however, the development of image processing algorithms and equipment has made current image-based techniques more sophisticated. This mini review aims to provide a succinct and accessible overview of image-based experimental measurement techniques to characterize the velocity field of blood microflow. The following techniques are introduced: cell tracking velocimetry, kymographs, micro-particle velocimetry, and dual-slit photometry as entry techniques for measuring various velocity fields either <italic>in vivo</italic> or <italic>in vitro</italic>.</p>
</abstract>
<kwd-group>
<kwd>microcirculation</kwd>
<kwd>kymographs</kwd>
<kwd>micro-particle velocimetry</kwd>
<kwd>dual-slit photometry</kwd>
<kwd>cell tracking</kwd>
</kwd-group>
<contract-sponsor id="cn001">Natural Sciences and Engineering Research Council of Canada<named-content content-type="fundref-id">10.13039/501100000038</named-content>
</contract-sponsor>
</article-meta>
</front>
<body>
<sec id="s1">
<title>Introduction</title>
<p>Microcirculation, which is composed of numerous vessels with diameters typically less than 50&#xa0;&#x3bc;m, is the main exchange site between blood and tissues. Because blood behavior in the microcirculation cannot be considered as a liquid flow, and is rather regarded as a collection of interacting particles in suspension (<xref ref-type="bibr" rid="B72">Secomb, 2017</xref>), the study of blood flow in the microcirculation represents a considerable challenge. Red blood cells (RBCs), which are the most abundant cells found in the blood (40% of the blood volume), may adversely affect blood viscosity (<xref ref-type="bibr" rid="B18">Coull et al., 1991</xref>; <xref ref-type="bibr" rid="B5">Baskurt and Meiselman, 2007</xref>; <xref ref-type="bibr" rid="B75">Silva-Herdade et al., 2016</xref>; <xref ref-type="bibr" rid="B76">Sloop et al., 2020</xref>). For instance, blood viscosity increases when blood cells are too abundant (as shown in Erythrocytosis (<xref ref-type="bibr" rid="B60">Pearson and Path, 2001</xref>) and hyperleukocytic leukemia (<xref ref-type="bibr" rid="B73">Sharma et al., 1992</xref>), less deformable than healthy cells (sickle cell disorders (<xref ref-type="bibr" rid="B17">Connes et al., 2016</xref>), hemolytic anemia (<xref ref-type="bibr" rid="B27">Johnson and Ravindranath, 1996</xref>), and falciparum anemia (<xref ref-type="bibr" rid="B56">Parrow et al., 2018</xref>)), or if they tend to aggregate abnormally (observed in a variety of clinical states such as burns (<xref ref-type="bibr" rid="B39">Levin and Egorihina, 2011</xref>), infections and sepsis (<xref ref-type="bibr" rid="B6">Baskurt and Meiselman, 2013</xref>), complicated diabetes mellitus (<xref ref-type="bibr" rid="B36">Le Devehat et al., 1990</xref>), and malignant and rheumatic diseases (<xref ref-type="bibr" rid="B45">Luquita et al., 2009</xref>)). Velocity characterization is a key measurement in numerous studies, such as those analyzing the impact on microcirculation on cellular interactions due to aggregation, blood cell congestion, or platelet migration, to provide useful insights into the mechanisms of disease or to study therapeutic solutions (<xref ref-type="bibr" rid="B8">Bishop et al., 2001a</xref>; <xref ref-type="bibr" rid="B44">Long et al., 2004</xref>; <xref ref-type="bibr" rid="B24">Ishikawa et al., 2011</xref>; <xref ref-type="bibr" rid="B28">Kaliviotis et al., 2011</xref>; <xref ref-type="bibr" rid="B74">Sherwood et al., 2012</xref>; <xref ref-type="bibr" rid="B62">Pitts and Fenech, 2013b</xref>; <xref ref-type="bibr" rid="B29">Kaliviotis et al., 2018</xref>; <xref ref-type="bibr" rid="B58">Passos et al., 2019</xref>). The advent of microfluidics technology has propelled <italic>in vitro</italic> studies pertaining to the flow behavior of blood or blood cells in microchannels and the development of blood lab-on-a-chip platforms (<xref ref-type="bibr" rid="B30">Khalid et al., 2017</xref>; <xref ref-type="bibr" rid="B47">Maria et al., 2017</xref>; <xref ref-type="bibr" rid="B71">Sebastian and Dittrich, 2018</xref>; <xref ref-type="bibr" rid="B58">Passos et al., 2019</xref>; <xref ref-type="bibr" rid="B2">Abay et al., 2020</xref>; <xref ref-type="bibr" rid="B46">Mantegazza et al., 2020</xref>; <xref ref-type="bibr" rid="B32">Kihm et al., 2021</xref>).</p>
<p>Blood microcirculation studies are performed either <italic>in vivo</italic>, using intra-vital microscopy, or in a more controlled <italic>in vitro</italic> environment, taking advantage of the recent development and accessibility of microfluidic chips. The methods described here are image-based measurement techniques that are used in either <italic>in vivo</italic> or <italic>in vitro</italic> context, or are sometimes used in both contexts. Over the years, with the increase in the camera sampling frequency, advances in image processing techniques, and increase in computer calculation capacity, the original image-based method (cell tracking) has evolved into more complex methods that coexist and evolve in parallel. Although the choice of the method seems to be linked to the research community (<italic>in vivo</italic> vs <italic>in vitro</italic>) or to the experience of the research group and available equipment, this mini review aims to better guide the choice of a suitable method for a desired application by highlighting the capabilities and limitations of different methods. <xref ref-type="table" rid="T1">Table 1</xref> summarizes key information as a quick guide.</p>
<table-wrap id="T1" position="float">
<label>TABLE 1</label>
<caption>
<p>Comparison of image-based experimental measurement techniques to characterize velocity fields in blood microflows.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="left"/>
<th align="center">Cell tracking</th>
<th align="center">Kymograph</th>
<th align="center">Micro-PIV</th>
<th align="center">Dual slit</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">Tracers</td>
<td align="left">Cells</td>
<td align="left">Speckles from RBC shadows</td>
<td align="left">RBCs or fluorescent microparticles</td>
<td align="left">Speckles from RBC shadows</td>
</tr>
<tr>
<td align="left">Image processing algorithms</td>
<td align="left">See note</td>
<td align="left">Kymograph</td>
<td align="left">Cross-correlation</td>
<td align="left">Cross-correlation</td>
</tr>
<tr>
<td align="left">Critical parameters</td>
<td align="left">
<italic>dt</italic>
</td>
<td align="left">Image stability, focus, requires a flat (2-dimensional) microcirculation bed</td>
<td align="left">DOC, <italic>dt</italic>, size and shape of CCW</td>
<td align="left">DOC, relative position of the slits, slits shape</td>
</tr>
<tr>
<td align="left">Hematocrit</td>
<td align="left">&#x3c;1%</td>
<td align="left">Not reported</td>
<td align="left">&#x3c;20%</td>
<td align="left">Not reported</td>
</tr>
<tr>
<td align="left">Provide: characteristic velocity</td>
<td align="left">yes</td>
<td align="left">yes</td>
<td align="left">yes</td>
<td align="left">yes</td>
</tr>
<tr>
<td align="left">Provide: velocity profile</td>
<td align="left">yes</td>
<td align="left">no</td>
<td align="left">yes</td>
<td align="left">yes</td>
</tr>
<tr>
<td align="left">Provide: 2D velocity field in the vessel</td>
<td align="left">yes</td>
<td align="left">no</td>
<td align="left">yes</td>
<td align="left">yes</td>
</tr>
<tr>
<td align="left">Provide: 3D velocity field in the vessel</td>
<td align="left">no</td>
<td align="left">no</td>
<td align="left">yes, e.g., using confocal microscopy</td>
<td align="left">no</td>
</tr>
<tr>
<td rowspan="4" align="left">Associated blood structural characteristics commonly explored in conjunction with velocity field</td>
<td align="left">Aggregate size</td>
<td align="left">Cell depleted layer</td>
<td align="left">Aggregate size</td>
<td rowspan="4" align="left"/>
</tr>
<tr>
<td align="left">Spatial distribution of red blood cells</td>
<td rowspan="3" align="left">Microcirculation velocity distribution</td>
<td align="left">Hematocrit Profile</td>
</tr>
<tr>
<td align="left">Cell depleted layer</td>
<td align="left">Cell depleted layer</td>
</tr>
<tr>
<td align="left">Viscosity Distribution</td>
<td align="left">Viscosity Distribution</td>
</tr>
<tr>
<td align="left">Possibility to investigate unsteady flow</td>
<td align="left">yes</td>
<td align="left">Limited</td>
<td align="left">limited</td>
<td align="left">no</td>
</tr>
<tr>
<td rowspan="2" align="left">Typical Experimental equipment</td>
<td rowspan="2" align="left">a high-speed camera, a microscope</td>
<td align="left">Kymograph only: a high-speed camera, a microscope</td>
<td rowspan="2" align="left">a light sensitive and short interframe times camera (double frame or high speed), a double pulsed laser with appropriate beam coupling and guiding, an epifluorescence microscope (single channel or stereo)</td>
<td rowspan="2" align="left">Photosensor (photodiodes, phototransistors, optical fibers) or a high-speed camera, a microscope</td>
</tr>
<tr>
<td align="left">
<italic>In vivo</italic>: a portable high-speed camera with darkfield capacity coupled with an appropriate lens and a sterile disposable cap</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn>
<p>Note: Examples of cell tracking algorithms (not necessary RBC): multiple-hypothesis tracking of extracted cell barycenters, local optimization using a cost function within spatially limited search regions, state-space diagram optimization in a greedy fashion, nearest-neighbor tracking of extracted centers of mass, and iterative spatial-temporal association based on three-dimensional connectivity for 2D data (<xref ref-type="bibr" rid="B48">Ma&#x161;ka et al., 2014</xref>).</p>
</fn>
</table-wrap-foot>
</table-wrap>
</sec>
<sec id="s2">
<title>
<italic>In vivo</italic> vs <italic>in vitro</italic> Studies</title>
<p>Numerous methods, such as Doppler, thermodilution, and dye injection, have been used to investigate microvascular flows (<xref ref-type="bibr" rid="B22">Gutterman et al., 2016</xref>; <xref ref-type="bibr" rid="B72">Secomb, 2017</xref>). However, here, we will focus only on image-based methods.</p>
<p>Intravital microscopy involves the observation of phenomena occurring in living organisms through a microscope. The simplest method is to operate on a small animal and exteriorize an organ, usually in the peritoneum, to be able to image it, which offers visualization of a flat microcirculatory network. The organ is immersed in a saline solution and immobilized with stitches (<xref ref-type="bibr" rid="B7">Bishop et al., 2001b</xref>; <xref ref-type="bibr" rid="B44">Long et al., 2004</xref>). Other research groups have opted for the implementation of a viewing window, which makes it possible to keep the animal alive for several days and to observe the spatial and temporal evolution of the microcirculation (<xref ref-type="bibr" rid="B59">Patumraj et al., 2005</xref>; <xref ref-type="bibr" rid="B11">Cabrales and Carvalho, 2010</xref>; <xref ref-type="bibr" rid="B32">Kihm et al., 2021</xref>).</p>
<p>Intravital microscopy images contain several artifacts that can influence velocity calculations, such as physiological movements, dilation and contraction of vessels, superposition of vessels in the organ, and light scattering. Open-source image processing tools are available to stabilize the images (e.g., the image stabilizer plugin for ImageJ (<xref ref-type="bibr" rid="B40">Li and Kang, 2008</xref>)).</p>
<p>For <italic>in vivo</italic> studies, the velocity characterization methods aim for a characteristic velocity along each vessel (average velocity or maximum velocity), and the velocity field is then the map of velocities in the microcirculatory network, as shown in <xref ref-type="fig" rid="F1">Figure 1A</xref>. In contrast, in <italic>in vitro</italic> studies on a single vessel, the methods seek to characterize the velocity profile along a line (<xref ref-type="fig" rid="F1">Figure 1B</xref>) or velocity field in a cross-section (<xref ref-type="fig" rid="F1">Figure 1C</xref>), and sometimes even the 3D velocity field (<xref ref-type="fig" rid="F1">Figure 1D</xref>). <italic>In vitro</italic> studies, although less physiologically representative, offer the possibility of controlling parameters, such as geometry, flow rate, cell concentration, and pressure drop, while allowing better quantitative and qualitative velocity measurements.</p>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption>
<p>
<bold>(A-D)</bold>: Visual comparison of typical velocity fields. <bold>(A)</bold> Color map of local velocity in a conjunctival microcirculation network. Color bar represents velocity in units of mm/s. The velocity vectors were obtained using kymographs image reused per United States government copyright (<xref ref-type="bibr" rid="B31">Khansari et al., 2015</xref>). <bold>(B)</bold> Field of 2D velocity vectors profile across a glass round 150&#xa0;mm diameter capillary channel where blood, at 10% hematocrit, was flowing at a flow rate of 11.5&#xa0;ml/min. The velocity vectors were obtained in our lab using micro-PIV. <bold>(C)</bold> Space-time averaged velocity corresponding to the field of 2D velocity vectors presenting in <bold>(B)</bold>. <bold>(D)</bold> Instantaneous 3D velocity profile of blood sample at 17% hematocrit in the central plane of a rectangular microchannel in in vitro analysis. Data were obtained using confocal micro-PIV, image reused with permission, copyright, 2022, Elsevier (<xref ref-type="bibr" rid="B41">Lima et al., 2007</xref>). <bold>(E-H)</bold>: Methods&#x2019; schematic of velocity determination <bold>(E)</bold> Cell tracking. The image presents <italic>in vitro</italic> RBCs in semi-circular curved channel <bold>(F)</bold> Kymograph. The image presents <italic>in vivo</italic> Sublingual microcirculation. <bold>(G)</bold> Micro-PIV. Images show fluorescent particles in the blood. <bold>(H)</bold> Dual slit photometry.</p>
</caption>
<graphic xlink:href="fphys-13-886675-g001.tif"/>
</fig>
<p>All the methods presented here have a potential to be applied to <italic>in vivo</italic> and <italic>in vitro</italic> studies; however, typically, when red blood cell velocity is investigated in a single vessel, cell tracking velocimetry is used, while when a full network is to be analyzed, automatic vessel detection using the kymograph method is more popularly employed. For more detailed velocity field characterization, micro-particle image velocimetry (micro-PIV) and dual-slit methods are the reference methodologies; however, more advanced expertise is required.</p>
</sec>
<sec id="s3">
<title>Cell Tracking Velocimetry</title>
<p>This technique involves identifying matching particles between the frames to link the positions. The velocities of the particles are then evaluated by dividing the time taken between each consecutive frame (<xref ref-type="fig" rid="F1">Figure 1E</xref>). The first studies using cell tracking velocimetry were published in the 1960s (<xref ref-type="bibr" rid="B10">Bugliarello and Hayden, 1962</xref>). This method is simple to implement and captures temporal and spatial speed variations. It is mainly used <italic>in vivo</italic> and <italic>ex-vivo</italic>, but is also used <italic>in vitro</italic> (<xref ref-type="bibr" rid="B55">Omori et al., 2015</xref>). The first analysis was performed manually, but with the advent of computer automation, simple free access algorithms are available for quick analysis (<xref ref-type="bibr" rid="B21">Gonciarz, 2021</xref>). However, the simplicity of this method leads to several limitations. For instance, to be able to identify individual blood cells, the hematocrit, i.e., the RBC volume fraction, must be very low, or a small fraction of the cells must be fluorescently stained for tracking. RBC staining is a simple procedure that is easy to implement <italic>in vitro</italic>, and it has also been used <italic>in vivo</italic> in small animals (<xref ref-type="bibr" rid="B23">Horan et al., 1990</xref>; <xref ref-type="bibr" rid="B4">Asai et al., 2007</xref>; <xref ref-type="bibr" rid="B3">Agrawal et al., 2017</xref>). Only particles in the plane of interest (or focus) should be tracked; this can be done by visual inspection, however, automatic processing considers out-of-focus particles. In addition, RBCs can group due to aggregation, resulting in the tracked objects changing in size, disappearing due to overlapping, or changing in shape due to their rotation. These occurrences affect the accuracy of the automatic image processing (<xref ref-type="bibr" rid="B53">Niazi et al., 2019</xref>). Despite these limitations, cell tracking is still a very efficient and accurate method that is widely used to track the passage of single blood cells in microfluidics. A review regarding the comparison of different tracking methods was performed by <xref ref-type="bibr" rid="B14">Chenouard et al. (2014)</xref>. Open source codes are available for simple tracking (e.g., (<xref ref-type="bibr" rid="B78">Tinevez et al., 2017</xref>; <xref ref-type="bibr" rid="B21">Gonciarz, 2021</xref>)). Some such codes include a position predictor (e.g., one based on a c) to account for cells that temporarily disappear, while more advanced tools integrate several popular machine learning algorithms to efficiently track objects from brightfield and fluorescence microscopy images (e.g., (39)).</p>
</sec>
<sec id="s4">
<title>Kymographs</title>
<p>In addition to studying the velocity in a specific vessel, intravital microscopy is also used to investigate tissue perfusion under changing conditions. Typically, studies aim to capture the spatial and temporal variability of microcirculation affecting perfusion. In animal studies, all organs can be investigated, while in human studies, nail, coronary (<xref ref-type="fig" rid="F1">Figure 1A</xref>), and sublingual microcirculation (<xref ref-type="fig" rid="F1">Figure 1F</xref>) can be accessed non-invasively, while microcirculation at other sites, such as the brain, can also be investigated using endoscopies or during surgery.</p>
<p>Common imaging approaches utilize sublingual orthogonal polarization spectral (OPS) imaging, side-stream dark field (SDF) imaging, and incident dark-field (IDF) imaging (<xref ref-type="bibr" rid="B19">Dobbe et al., 2008</xref>; <xref ref-type="bibr" rid="B49">Massey and Shapiro, 2016</xref>) to record videos of microcirculation activity with enhanced contrast. In either case, high-speed image collection, typically &#x3e;60 frames per second (fps), is required. For intravital microscopy, image stabilization is the first step in image analysis because of physiologically induced motions such as respiration and cardiac activity. Thus, vessel segmentation is necessary to identify the vasculature as shown in <xref ref-type="fig" rid="F1">Figure 1A</xref>. Finally, the RBC velocities are determined using space&#x2013;time diagrams, called kymographs, for every time interval and for every vascular segment. An example of a kymograph is shown in <xref ref-type="fig" rid="F1">Figure 1F</xref>. A kymograph is obtained by plotting the intensity in the grayscale level along the vessel segment over time. On this new &#x201c;image,&#x201d; where space is encoded along the <italic>x</italic>-axis while time is plotted along the <italic>y</italic>-axis, velocity is then deduced from red blood cell shadow (speckles) angles (<xref ref-type="bibr" rid="B25">J&#xe4;hne, 2005</xref>).</p>
<p>Typically, flow characterizations are presented as a color-coded velocity map, as illustrated in <xref ref-type="fig" rid="F1">Figure 1A</xref>. Few commercial software packages are available to complete the full procedure (image acquisition, stabilization, segmentation, and velocity characterization) such as AVA (Microvision Medical B.V., Amsterdam, Netherlands) and CapiScope (KK Research Technology Ltd., Devon, England). The procedure was also implemented in the open source image software ImageJ under the name STAFF (<xref ref-type="bibr" rid="B15">Clendenon et al., 2019a</xref>; <xref ref-type="bibr" rid="B16">Clendenon et al., 2019b</xref>).</p>
<p>The method is highly dependent on the image quality, particularly image contrast and image sharpness. While illumination techniques have improved, the sharpness of the image is still an important limiting factor because the focus may be difficult to obtain when adjusting the lens on soft tissues and on living subjects, especially during bedside techniques, such as sublingual microcirculation, when the patient is awake. Companies manufacturing commercial acquisition devices, such as USB3 MicroScan (Microvision Medical B.V., Amsterdam, Netherlands), are still improving their focus-monitoring options.</p>
</sec>
<sec id="s5">
<title>Micro Particle Image Velocimetry</title>
<p>Micro-PIV has been developed to determine the velocity field in microfluidics (<xref ref-type="bibr" rid="B69">Santiago et al., 1998</xref>), and since 2000, it has been used to characterize the velocity profiles of blood flowing through micro-channels (<xref ref-type="bibr" rid="B54">Okuda et al., 2003</xref>; <xref ref-type="bibr" rid="B35">Koutsiaris and Pogiatzi, 2004</xref>; <xref ref-type="bibr" rid="B9">Bitsch et al., 2005</xref>; <xref ref-type="bibr" rid="B43">Lima et al., 2006</xref>; <xref ref-type="bibr" rid="B57">Pasias et al., 2020</xref>). This technique is a particle-based flow visualization method. <xref ref-type="fig" rid="F1">Figure 1G</xref> presents the schematic of the method. Under a microscope, two sequential images of the microflow are recorded at a known time interval (<italic>dt</italic>) at a fixed position. The pairs of images are used to determine the movement of a group of particles from the first image in the pair to the second image using cross-correlation within sub-regions known as cross-correlation windows (CCW). An interrogation window in the first image is compared within an interrogation window grid in the second image to find the most look-alike windows. The distance between the centers of both windows can be divided by the time elapsed between each frame to calculate the mean velocity of the particles for this position. To capture the displacement of the particles in a micrometric field of view, <italic>dt</italic> is set in conjunction with the size of the CCW. The average particle displacement between consecutive frames should be approximately a quarter of the size of the CCW (<xref ref-type="bibr" rid="B70">Scharnowski and K&#xe4;hler, 2020</xref>) (from ms to &#x3bc;s depending on the lens magnification and flow velocity). This is a critical parameter because if <italic>dt</italic> is too large, the particles of the first image could pass beyond the second CCW, resulting in a loss of correlation.</p>
<p>Because this method is a particle-based technique, tracer particles are required. <italic>In vivo</italic> vs <italic>in vitro</italic> applications of micro-PIV require different equipment and execution choices. Traditionally, <italic>in vivo</italic> applications require high-speed photography using the RBCs themselves as tracers (<xref ref-type="bibr" rid="B77">Sugii et al., 2002</xref>; <xref ref-type="bibr" rid="B35">Koutsiaris and Pogiatzi, 2004</xref>; <xref ref-type="bibr" rid="B9">Bitsch et al., 2005</xref>; <xref ref-type="bibr" rid="B37">Lee et al., 2007</xref>; <xref ref-type="bibr" rid="B33">Kikuchi and Mochizuki, 2011</xref>), while in <italic>in vitro</italic> studies, artificial micro-fluorescent particles are added to the blood (<xref ref-type="bibr" rid="B54">Okuda et al., 2003</xref>; <xref ref-type="bibr" rid="B43">Lima et al., 2006</xref>; <xref ref-type="bibr" rid="B41">Lima et al., 2007</xref>; <xref ref-type="bibr" rid="B42">Lima et al., 2008</xref>; <xref ref-type="bibr" rid="B63">Pitts et al., 2012</xref>; <xref ref-type="bibr" rid="B61">Pitts and Fenech, 2013a</xref>; <xref ref-type="bibr" rid="B50">Mehri et al., 2015</xref>; <xref ref-type="bibr" rid="B51">Mehri et al., 2018</xref>; <xref ref-type="bibr" rid="B57">Pasias et al., 2020</xref>). Artificial tracer particles have also been used in living subjects in the chicken vitelline network, and embryonic heart (<xref ref-type="bibr" rid="B64">Poelma et al., 2008</xref>). Obtaining three-dimensional profiles of cell suspension flow is also possible by coupling micro-PIV with confocal microscopy (<xref ref-type="bibr" rid="B43">Lima et al., 2006</xref>). Micro-PIV offers a robust and accurate tool to characterize micro blood flows in 2D or 3D; however, the main disadvantage of this technique is the limitation in cell concentration, as the accuracy drops for RBC concentrations above 20% as the ability to resolve the particles decreases.</p>
</sec>
<sec id="s6">
<title>Dual Slit Photometry</title>
<p>Dual-slit photometry is a technique developed by Wayland and Johnson (<xref ref-type="bibr" rid="B79">Wayland and Johnson, 1967</xref>) and is used to estimate the flow velocity and volumetric flow rates in microchannels (<xref ref-type="bibr" rid="B38">Lee et al., 1983</xref>). With optimized settings, it can be used to measure maximal velocity in microchannels both <italic>in vivo</italic> and <italic>in vitro</italic> (<xref ref-type="bibr" rid="B68">Roman et al., 2012b</xref>). The dual slit is a photometric technique that utilizes two photo sensors (slits) positioned along the vessel. The photosensors can be either photodiode sensors or are taken as two regions of interest in a digitized image. In order to obtain a full velocity profile, the slits&#x2019; width could be selected to be as small as 1 to 3 pixels, allowing for multiple velocity measurements along the cross-section of the channel (<xref ref-type="bibr" rid="B67">Roman et al., 2012a</xref>). <xref ref-type="fig" rid="F1">Figure 1H</xref> presents the schematic of the method. In each slit, light fluctuations (speckles) are produced by the passage of the RBC flowing through the vessel. A time-dependent signal is captured for each slit in which the time delay between the two signals is obtained by temporal cross-correlation. The RBC velocities are then estimated by assessing the distance between the two slits.</p>
<p>Owing to the large number of RBCs in the channel, the difference in contrast between the cells and suspension media must be sharp to provide a good signal. Furthermore, the RBC rotation, shape, and migration in channels with larger diameters can result in two different signal outputs, preventing an accurate estimation of the velocity profile. For optimized measurement, the technique should be applied to vessels or microchannels that are linear where the slits can be placed at 5 to 10 particle size apart. Finally, the flow through the vessel must be steady, as the technique requires time averaging to ensure statistical convergence of the temporal cross-correlation (<xref ref-type="bibr" rid="B68">Roman et al., 2012b</xref>).</p>
</sec>
<sec id="s7">
<title>Emergent Methods</title>
<p>Conventional methods to infer fluid velocity and pressure measurements or stress fields rely on either analyzing visual images as seen in the optical velocimetry techniques or by enforcing underlying physics without considering the visual data as completed in computational fluid dynamics (CFD). However, with the introduction of a physics-informed neural network, flow visualization image data, such as particles or injected-dye, can be used to derive quantitative information of the flow field while respecting any laws of physics described by a general partial differential equations (PDE) (<xref ref-type="bibr" rid="B65">Raissi et al., 2019</xref>). By encoding the Navier-Stokes equations into a neural network, the technique has been applied to flow visualization of both classical fluid problems and more complex flows such as the flow through a microaneurysm-on-a-chip (<xref ref-type="bibr" rid="B65">Raissi et al., 2019</xref>; <xref ref-type="bibr" rid="B66">Raissi et al., 2020</xref>; <xref ref-type="bibr" rid="B12">Cai et al., 2021</xref>). The steps for developing a physics-informed neural network include defining the underlying physical laws, configuring image data to be fed into the neural network, constructing the neural network architecture, training the neural network, verifying the robustness of the model, and finally deploying the model (<xref ref-type="bibr" rid="B66">Raissi et al., 2020</xref>; <xref ref-type="bibr" rid="B12">Cai et al., 2021</xref>).</p>
<p>The advantage of using a physics-informed neural network is its key property that it can be effectively trained using small datasets (<xref ref-type="bibr" rid="B65">Raissi et al., 2019</xref>). Furthermore, with 2D images from microfluidic experiments or from <italic>in vivo</italic> observations, a full estimate of the 3D velocity, pressure, and stress field of the system can be deduced, which may be challenging to measure experimentally or derive from the images alone (<xref ref-type="bibr" rid="B65">Raissi et al., 2019</xref>; <xref ref-type="bibr" rid="B66">Raissi et al., 2020</xref>; <xref ref-type="bibr" rid="B12">Cai et al., 2021</xref>). In contrast to traditional CFD methods, which are sensitive to boundary conditions, a physics-informed neural network can infer the flow field with the sequence of recorded data without any <italic>a priori</italic> knowledge of the inlet and outlet conditions. The implementation of a physics-informed neural network may also be considered more accessible as it can be implemented with open-source software such as TensorFlow (<xref ref-type="bibr" rid="B1">Abadi et al., 2016</xref>) on a powerful workstation or a local cluster (<xref ref-type="bibr" rid="B66">Raissi et al., 2020</xref>; <xref ref-type="bibr" rid="B12">Cai et al., 2021</xref>). However, the cost of utilizing a neural network for analysis is the computational cost of the development and training of the model itself, which is more computationally costly compared to simpler conventional optical methodologies relying only on visual images.</p>
</sec>
<sec sec-type="discussion" id="s8">
<title>Discussion</title>
<p>
<xref ref-type="table" rid="T1">Table 1</xref> presents a comparison of different methods and important parameters to inform decisions related to the method to be chosen for a specific study.</p>
<sec id="s8-1">
<title>Tracer Particles</title>
<p>Image-based experimental measurement techniques to characterize the velocity field of blood microflow utilize some form of tracer particles to visualize the flow. <italic>In vivo</italic>, natural tracers from the cells themselves can be used, while <italic>in vitro</italic> there are more options available for tracer selection from introducing microbeads, fluorescent molecules, or even marking the cells in the fluid sample. The use of RBCs has the advantage of not requiring particle injection and, more importantly, it avoids confounding interpretation attributed to the modification of the system under study. The use of RBCs as imaging tracers has nevertheless some disadvantages because their diameter is approximately 7&#xa0;&#x3bc;m, while the diameter of an artificial fluorescent particle is typically on the order of 1&#xa0;&#xb5;m. The higher RBC particle size and density are responsible for the decrease in accuracy of the measurement method, increasing the depth of correlation (DOC), i.e., the depth at which "the correlation signal of particles significantly contributes to the correlation function&#x201d; (<xref ref-type="bibr" rid="B34">Kloostermann et al., 2009</xref>; <xref ref-type="bibr" rid="B52">Nguyen et al., 2010</xref>; <xref ref-type="bibr" rid="B13">Chayer et al., 2012</xref>; <xref ref-type="bibr" rid="B61">Pitts and Fenech, 2013a</xref>). To minimize the effects of out-of-focus particles, &#x201c;image-overlapping post-processing&#x201d; method has proven to be beneficial specifically for blood micro-PIV (<xref ref-type="bibr" rid="B63">Pitts et al., 2012</xref>). When it is not possible to add tracer particles, it was shown that using RBCs as tracer particles has acceptable accuracy when analyzing for the value of the flow rate, but not when assessing for the specific shape of the velocity profile (<xref ref-type="bibr" rid="B13">Chayer et al., 2012</xref>; <xref ref-type="bibr" rid="B61">Pitts and Fenech, 2013a</xref>).</p>
</sec>
<sec id="s8-2">
<title>Volume Fraction and Cell Contrast</title>
<p>Image-based techniques are severely limited by the feeding hematocrit of the system; it is difficult to distinguish cells or tracer particles introduced into the fluid medium in high hematocrit studies. This effectively limits the study of the dynamics of blood microflows using imaging techniques, as the accuracy of measurements decreases as the hematocrit approaches values closer to the physiological values. The volume fraction is a significant factor to consider when selecting an optical measurement technique because if the cell concentration is too high, automatic cell tracking and PIV algorithms are less accurate, while the contrast of the cells can affect the accuracy of kymography and dual-slit photometry. Measuring flow fields in dense suspension of cells would require techniques that utilize sensors that can penetrate denser samples, such as ultrasound localization microscopy (<xref ref-type="bibr" rid="B20">Errico et al., 2015</xref>) or those with modifications to RBC opacity, such as converting RBCs into ghost cells (<xref ref-type="bibr" rid="B26">Jansen et al., 2016</xref>).</p>
</sec>
<sec id="s8-3">
<title>Type of Velocity Field</title>
<p>To extract a characteristic velocity, such as the mean or max velocity, any technique presented here can be utilized. However, to expand into the 2D velocity field of the vessel, cell tracking, micro-PIV, and dual-slit photometry should be considered; in micro-PIV, it is also possible to obtain 3D profiles with additional equipment. With the most basic equipment, the techniques are not necessarily independent and differ by the image processing algorithms that are applied to the acquired images; however, the optimal setting of certain factors, such as the channel configuration, lighting, and lens type, can drastically change the accuracy of the algorithm applied. To obtain more detailed velocity profiles in 3D or under a broad range of flowrates would require more sophisticated equipment such as cameras with higher acquisition rates, pulsed lasers, or filters. This can make profiling of the velocity field in blood microflow an expensive endeavor because the upfront cost of the equipment can be high.</p>
</sec>
</sec>
</body>
<back>
<sec id="s9">
<title>Author Contributions</title>
<p>AL and MF defined the scope of this mini review and contributed equally to the writing of the manuscript.</p>
</sec>
<sec id="s10">
<title>Funding</title>
<p>This work was funded by the Natural Science and Engineering Research Council of Canada (&#x23;RGPIN-2020-07020).</p>
</sec>
<sec sec-type="COI-statement" id="s11">
<title>Conflict of Interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec sec-type="disclaimer" id="s12">
<title>Publisher&#x2019;s Note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors, and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ref-list>
<title>References</title>
<ref id="B1">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Abadi</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Agarwal</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Barham</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Brevdo</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Citro</surname>
<given-names>C.</given-names>
</name>
<etal/>
</person-group> (<year>2016</year>). <source>TensorFlow: A system for Large-Scale Machine Learning</source>. <conf-name>In Proceedings of the 12th USENIX conference on Operating Systems Design and Implementation (OSDI&#x2019;16)</conf-name>, <publisher-name>USENIX Association</publisher-name>: <publisher-loc>Savannah, GA, USA</publisher-loc>, <fpage>265</fpage>&#x2013;<lpage>283</lpage>. </citation>
</ref>
<ref id="B2">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Abay</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Recktenwald</surname>
<given-names>S. M.</given-names>
</name>
<name>
<surname>John</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Kaestner</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Wagner</surname>
<given-names>C.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Cross-sectional Focusing of Red Blood Cells in a Constricted Microfluidic Channel</article-title>. <source>Soft Matter</source> <volume>16</volume> (<issue>2</issue>), <fpage>534</fpage>&#x2013;<lpage>543</lpage>. <pub-id pub-id-type="doi">10.1039/c9sm01740b</pub-id> </citation>
</ref>
<ref id="B3">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Agrawal</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Balne</surname>
<given-names>P. K.</given-names>
</name>
<name>
<surname>Tun</surname>
<given-names>S. B. B.</given-names>
</name>
<name>
<surname>Sia Wey</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Khandelwal</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Barathi</surname>
<given-names>V. A.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Fluorescent Dye Labeling of Erythrocytes and Leukocytes for Studying the Flow Dynamics in Mouse Retinal Circulation</article-title>. <source>J. Vis. Exp.</source> (<issue>125</issue>), <fpage>e55495</fpage>. <pub-id pub-id-type="doi">10.3791/55495</pub-id> </citation>
</ref>
<ref id="B4">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Asai</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Sahani</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Ouchi</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Martyn</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Yasuhara</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2007</year>). <article-title>
<italic>In Vivo</italic> Micro-circulation Measurement in Skeletal Muscle by Intra-vital Microscopy</article-title>. <source>J. Vis. Exp.</source> (<issue>4</issue>), <fpage>e210</fpage>. <pub-id pub-id-type="doi">10.3791/210</pub-id> </citation>
</ref>
<ref id="B5">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Baskurt</surname>
<given-names>O.</given-names>
</name>
<name>
<surname>Meiselman</surname>
<given-names>H. J.</given-names>
</name>
</person-group> (<year>2007</year>). &#x201c;<article-title>
<italic>In Vivo</italic> hemorheology</article-title>,&#x201d; in <source>Handbook of Hemorheology and Hemodynamics</source>. Editors <person-group person-group-type="editor">
<name>
<surname>Baskurt</surname>
<given-names>O. K.</given-names>
</name>
<name>
<surname>Hardeman</surname>
<given-names>M. R.</given-names>
</name>
<name>
<surname>Rampling</surname>
<given-names>M. W.</given-names>
</name>
</person-group> (<publisher-loc>Amsterdam</publisher-loc>: <publisher-name>IOS press</publisher-name>), <fpage>322</fpage>&#x2013;<lpage>338</lpage>. </citation>
</ref>
<ref id="B6">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Baskurt</surname>
<given-names>O. K.</given-names>
</name>
<name>
<surname>Meiselman</surname>
<given-names>H. J.</given-names>
</name>
</person-group> (<year>2013</year>). <article-title>Erythrocyte Aggregation: Basic Aspects and Clinical Importance</article-title>. <source>Clin. Hemorheol. Microcirc.</source> <volume>53</volume> (<issue>1&#x2013;2</issue>), <fpage>23</fpage>&#x2013;<lpage>37</lpage>. <pub-id pub-id-type="doi">10.3233/CH-2012-1573</pub-id> </citation>
</ref>
<ref id="B7">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bishop</surname>
<given-names>J. J.</given-names>
</name>
<name>
<surname>Popel</surname>
<given-names>A. S.</given-names>
</name>
<name>
<surname>Intaglietta</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Johnson</surname>
<given-names>P. C.</given-names>
</name>
</person-group> (<year>2001b</year>). <article-title>Rheological Effects of Red Blood Cell Aggregation in the Venous Network: A Review of Recent Studies</article-title>. <source>Biorheology</source> <volume>38</volume>, <fpage>263</fpage>&#x2013;<lpage>274</lpage>. </citation>
</ref>
<ref id="B8">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bishop</surname>
<given-names>J. J.</given-names>
</name>
<name>
<surname>Popel</surname>
<given-names>A. S.</given-names>
</name>
<name>
<surname>Intaglietta</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Johnson</surname>
<given-names>P. C.</given-names>
</name>
</person-group> (<year>2001a</year>). <article-title>Effects of Erythrocyte Aggregation and Venous Network Geometry on Red Blood Cell Axial Migration</article-title>. <source>Am. J. Physiology-Heart Circulatory Physiol.</source> <volume>281</volume> (<issue>2</issue>), <fpage>H939</fpage>&#x2013;<lpage>H950</lpage>. <pub-id pub-id-type="doi">10.1152/ajpheart.2001.281.2.h939</pub-id> </citation>
</ref>
<ref id="B9">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bitsch</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Olesen</surname>
<given-names>L. H.</given-names>
</name>
<name>
<surname>Westergaard</surname>
<given-names>C. H.</given-names>
</name>
<name>
<surname>Bruus</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Klank</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Kutter</surname>
<given-names>J. P.</given-names>
</name>
</person-group> (<year>2005</year>). <article-title>Micro Particle-Image Velocimetry of Bead Suspensions and Blood Flows</article-title>. <source>Exp. Fluids</source> <volume>39</volume> (<issue>3</issue>), <fpage>507</fpage>&#x2013;<lpage>513</lpage>. <pub-id pub-id-type="doi">10.1007/s00348-005-0967-7</pub-id> </citation>
</ref>
<ref id="B10">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bugliarello</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Hayden</surname>
<given-names>J. W.</given-names>
</name>
</person-group> (<year>1962</year>). <article-title>High-speed Microcinematographic Studies of Blood Flow <italic>In Vitro</italic>
</article-title>. <source>Science</source> <volume>138</volume>, <fpage>981</fpage>&#x2013;<lpage>983</lpage>. <pub-id pub-id-type="doi">10.1126/science.138.3544.981</pub-id> </citation>
</ref>
<ref id="B11">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cabrales</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Carvalho</surname>
<given-names>L. J. M.</given-names>
</name>
</person-group> (<year>2010</year>). <article-title>Intravital Microscopy of the Mouse Brain Microcirculation Using a Closed Cranial Window</article-title>. <source>J. Vis. Exp.</source> (<issue>45</issue>), <fpage>2184</fpage>. <pub-id pub-id-type="doi">10.3791/2184</pub-id> </citation>
</ref>
<ref id="B12">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cai</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Zheng</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Kong</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Dao</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Karniadakis</surname>
<given-names>G. E.</given-names>
</name>
<etal/>
</person-group> (<year>2021</year>). <article-title>Artificial Intelligence Velocimetry and Microaneurysm-On-A-Chip for Three-Dimensional Analysis of Blood Flow in Physiology and Disease</article-title>. <source>Proc. Natl. Acad. Sci. U.S.A.</source> <volume>118</volume> (<issue>13</issue>), <fpage>e2100697118</fpage>. <pub-id pub-id-type="doi">10.1073/pnas.2100697118</pub-id> </citation>
</ref>
<ref id="B13">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Chayer</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>L Pitts</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Cloutier</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Fenech</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2012</year>). <article-title>Velocity Measurement Accuracy in Optical Microhemodynamics: Experiment and Simulation</article-title>. <source>Physiol. Meas.</source> <volume>33</volume> (<issue>10</issue>), <fpage>1585</fpage>&#x2013;<lpage>1602</lpage>. <pub-id pub-id-type="doi">10.1088/0967-3334/33/10/1585</pub-id> </citation>
</ref>
<ref id="B14">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Chenouard</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Smal</surname>
<given-names>I.</given-names>
</name>
<name>
<surname>de Chaumont</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Ma&#x161;ka</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Sbalzarini</surname>
<given-names>I. F.</given-names>
</name>
<name>
<surname>Gong</surname>
<given-names>Y.</given-names>
</name>
<etal/>
</person-group> (<year>2014</year>). <article-title>Objective Comparison of Particle Tracking Methods</article-title>. <source>Nat. Methods</source> <volume>11</volume> (<issue>3</issue>), <fpage>281</fpage>&#x2013;<lpage>289</lpage>. <pub-id pub-id-type="doi">10.1038/nmeth.2808</pub-id> </citation>
</ref>
<ref id="B15">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Clendenon</surname>
<given-names>S. G.</given-names>
</name>
<name>
<surname>Fu</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Von Hoene</surname>
<given-names>R. A.</given-names>
</name>
<name>
<surname>Clendenon</surname>
<given-names>J. L.</given-names>
</name>
<name>
<surname>Sluka</surname>
<given-names>J. P.</given-names>
</name>
<name>
<surname>Winfree</surname>
<given-names>S.</given-names>
</name>
<etal/>
</person-group> (<year>2019a</year>). <article-title>A Simple Automated Method for Continuous Fieldwise Measurement of Microvascular Hemodynamics</article-title>. <source>Microvasc. Res.</source> <volume>123</volume>, <fpage>7</fpage>&#x2013;<lpage>13</lpage>. <pub-id pub-id-type="doi">10.1016/j.mvr.2018.11.010</pub-id> </citation>
</ref>
<ref id="B16">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Clendenon</surname>
<given-names>S. G.</given-names>
</name>
<name>
<surname>Fu</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Von Hoene</surname>
<given-names>R. A.</given-names>
</name>
<name>
<surname>Clendenon</surname>
<given-names>J. L.</given-names>
</name>
<name>
<surname>Sluka</surname>
<given-names>J. P.</given-names>
</name>
<name>
<surname>Winfree</surname>
<given-names>S.</given-names>
</name>
<etal/>
</person-group> (<year>2019b</year>). <article-title>Spatial Temporal Analysis of Fieldwise Flow in Microvasculature</article-title>. <source>J. Vis. Exp.</source> (<issue>153</issue>), <fpage>e60493</fpage>. <pub-id pub-id-type="doi">10.3791/60493</pub-id> </citation>
</ref>
<ref id="B17">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Connes</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Alexy</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Detterich</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Romana</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Hardy-Dessources</surname>
<given-names>M.-D.</given-names>
</name>
<name>
<surname>Ballas</surname>
<given-names>S. K.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>The Role of Blood Rheology in Sickle Cell Disease</article-title>. <source>Blood Rev.</source> <volume>30</volume> (<issue>2</issue>), <fpage>111</fpage>&#x2013;<lpage>118</lpage>. <pub-id pub-id-type="doi">10.1016/j.blre.2015.08.005</pub-id> </citation>
</ref>
<ref id="B18">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Coull</surname>
<given-names>B. M.</given-names>
</name>
<name>
<surname>Beamer</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>de Garmo</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Sexton</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Nordt</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Knox</surname>
<given-names>R.</given-names>
</name>
<etal/>
</person-group> (<year>1991</year>). <article-title>Chronic Blood Hyperviscosity in Subjects with Acute Stroke, Transient Ischemic Attack, and Risk Factors for Stroke</article-title>. <source>Stroke</source> <volume>22</volume> (<issue>2</issue>), <fpage>162</fpage>&#x2013;<lpage>168</lpage>. <pub-id pub-id-type="doi">10.1161/01.STR.22.2.162</pub-id> </citation>
</ref>
<ref id="B19">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Dobbe</surname>
<given-names>J. G. G.</given-names>
</name>
<name>
<surname>Streekstra</surname>
<given-names>G. J.</given-names>
</name>
<name>
<surname>Atasever</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>van Zijderveld</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Ince</surname>
<given-names>C.</given-names>
</name>
</person-group> (<year>2008</year>). <article-title>Measurement of Functional Microcirculatory Geometry and Velocity Distributions Using Automated Image Analysis</article-title>. <source>Med. Biol. Eng. Comput.</source> <volume>46</volume> (<issue>7</issue>), <fpage>659</fpage>. <pub-id pub-id-type="doi">10.1007/s11517-008-0349-4</pub-id> </citation>
</ref>
<ref id="B20">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Errico</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Pierre</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Pezet</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Desailly</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Lenkei</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Couture</surname>
<given-names>O.</given-names>
</name>
<etal/>
</person-group> (<year>2015</year>). <article-title>Ultrafast Ultrasound Localization Microscopy for Deep Super-resolution Vascular Imaging</article-title>. <source>Nature</source> <volume>527</volume> (<issue>7579</issue>), <fpage>499</fpage>&#x2013;<lpage>502</lpage>. <pub-id pub-id-type="doi">10.1038/nature16066</pub-id> </citation>
</ref>
<ref id="B21">
<citation citation-type="web">
<person-group person-group-type="author">
<name>
<surname>Gonciarz</surname>
<given-names>K.</given-names>
</name>
</person-group> (<year>2021</year>) <article-title>Particle Tracker, Image J. Dresden, Germany</article-title>. <comment>Available at: <ext-link ext-link-type="uri" xlink:href="https://imagej.net/plugins/particle-tracker">https://imagej.net/plugins/particle-tracker</ext-link>, (Accessed April 08, 2022)</comment>. </citation>
</ref>
<ref id="B22">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gutterman</surname>
<given-names>D. D.</given-names>
</name>
<name>
<surname>Chabowski</surname>
<given-names>D. S.</given-names>
</name>
<name>
<surname>Kadlec</surname>
<given-names>A. O.</given-names>
</name>
<name>
<surname>Durand</surname>
<given-names>M. J.</given-names>
</name>
<name>
<surname>Freed</surname>
<given-names>J. K.</given-names>
</name>
<name>
<surname>Ait-Aissa</surname>
<given-names>K.</given-names>
</name>
<etal/>
</person-group> (<year>2016</year>). <article-title>The Human Microcirculation</article-title>. <source>Circ. Res.</source> <volume>118</volume> (<issue>1</issue>), <fpage>157</fpage>&#x2013;<lpage>172</lpage>. <pub-id pub-id-type="doi">10.1161/CIRCRESAHA.115.305364</pub-id> </citation>
</ref>
<ref id="B23">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Horan</surname>
<given-names>P. K.</given-names>
</name>
<name>
<surname>Melnicoff</surname>
<given-names>M. J.</given-names>
</name>
<name>
<surname>Jensen</surname>
<given-names>B. D.</given-names>
</name>
<name>
<surname>Slezak</surname>
<given-names>S. E.</given-names>
</name>
</person-group> (<year>1990</year>). <article-title>Chapter 42 Fluorescent Cell Labeling for <italic>In Vivo</italic> and <italic>In Vitro</italic> Cell Tracking</article-title>. <source>Methods Cel Biol.</source> <volume>33</volume>, <fpage>469</fpage>&#x2013;<lpage>490</lpage>. <pub-id pub-id-type="doi">10.1016/S0091-679X(08)60547-6</pub-id> </citation>
</ref>
<ref id="B24">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ishikawa</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Fujiwara</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Matsuki</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Yoshimoto</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Imai</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Ueno</surname>
<given-names>H.</given-names>
</name>
<etal/>
</person-group> (<year>2011</year>). <article-title>Asymmetry of Blood Flow and Cancer Cell Adhesion in a Microchannel with Symmetric Bifurcation and confluence</article-title>. <source>Biomed. Microdevices</source> <volume>13</volume> (<issue>1</issue>), <fpage>159</fpage>&#x2013;<lpage>167</lpage>. <pub-id pub-id-type="doi">10.1007/s10544-010-9481-7</pub-id> </citation>
</ref>
<ref id="B25">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>J&#xe4;hne</surname>
<given-names>B.</given-names>
</name>
</person-group> (<year>2005</year>). <source>Digital Image Processing: 6th Revised and Extended Edition</source>. <publisher-loc>Berlin</publisher-loc>: <publisher-name>Springer</publisher-name>, <fpage>403</fpage>&#x2013;<lpage>406</lpage>. <pub-id pub-id-type="doi">10.1007/3-540-27563-0</pub-id> </citation>
</ref>
<ref id="B26">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Jansen</surname>
<given-names>S. V.</given-names>
</name>
<name>
<surname>M&#xfc;ller</surname>
<given-names>I.</given-names>
</name>
<name>
<surname>Nachtsheim</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Schmitz-Rode</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Steinseifer</surname>
<given-names>U.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Ghost Cell Suspensions as Blood Analogue Fluid for Macroscopic Particle Image Velocimetry Measurements</article-title>. <source>Artif. Organs</source> <volume>40</volume> (<issue>2</issue>), <fpage>207</fpage>&#x2013;<lpage>212</lpage>. <pub-id pub-id-type="doi">10.1111/aor.12511</pub-id> </citation>
</ref>
<ref id="B27">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Johnson</surname>
<given-names>R. M.</given-names>
</name>
<name>
<surname>Ravindranath</surname>
<given-names>Y.</given-names>
</name>
</person-group> (<year>1996</year>). <article-title>Osmotic Scan Ektacytometry in Clinical Diagnosis</article-title>. <source>J. Pediatr. Hematology/Oncology</source> <volume>18</volume> (<issue>2</issue>), <fpage>122</fpage>&#x2013;<lpage>129</lpage>. <pub-id pub-id-type="doi">10.1097/00043426-199605000-00005</pub-id> </citation>
</ref>
<ref id="B28">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kaliviotis</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Dusting</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Balabani</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2011</year>). <article-title>Spatial Variation of Blood Viscosity: Modelling Using Shear fields Measured by a &#x3bc;PIV Based Technique</article-title>. <source>Med. Eng. Phys.</source> <volume>33</volume> (<issue>7</issue>), <fpage>824</fpage>&#x2013;<lpage>831</lpage>. <pub-id pub-id-type="doi">10.1016/j.medengphy.2010.09.004</pub-id> </citation>
</ref>
<ref id="B29">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kaliviotis</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Sherwood</surname>
<given-names>J. M.</given-names>
</name>
<name>
<surname>Balabani</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Local Viscosity Distribution in Bifurcating Microfluidic Blood Flows</article-title>. <source>Phys. Fluids</source> <volume>30</volume>, <fpage>030706</fpage>. <pub-id pub-id-type="doi">10.1063/1.5011373</pub-id> </citation>
</ref>
<ref id="B30">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Khalid</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Kobayashi</surname>
<given-names>I.</given-names>
</name>
<name>
<surname>Nakajima</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Recent Lab&#x2010;on&#x2010;chip Developments for Novel Drug Discovery</article-title>. <source>Wires Syst. Biol. Med.</source> <volume>9</volume>, <fpage>e1381</fpage>. <pub-id pub-id-type="doi">10.1002/wsbm.1381</pub-id> </citation>
</ref>
<ref id="B31">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Khansari</surname>
<given-names>M. M.</given-names>
</name>
<name>
<surname>Wanek</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>E Felder</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Camardo</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Shahidi</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>Automated Assessment of Hemodynamics in the Conjunctival Microvasculature Network</article-title>. <source>IEEE Trans. Med. Imaging</source> <volume>35</volume> (<issue>2</issue>), <fpage>605</fpage>&#x2013;<lpage>611</lpage>. <pub-id pub-id-type="doi">10.1109/TMI.2015.2486619</pub-id> </citation>
</ref>
<ref id="B32">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kihm</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Quint</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Laschke</surname>
<given-names>M. W.</given-names>
</name>
<name>
<surname>Menger</surname>
<given-names>M. D.</given-names>
</name>
<name>
<surname>John</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Kaestner</surname>
<given-names>L.</given-names>
</name>
<etal/>
</person-group> (<year>2021</year>). <article-title>Lingering Dynamics in Microvascular Blood Flow</article-title>. <source>Biophysical J.</source> <volume>120</volume> (<issue>3</issue>), <fpage>432</fpage>&#x2013;<lpage>439</lpage>. <pub-id pub-id-type="doi">10.1016/J.BPJ.2020.12.012</pub-id> </citation>
</ref>
<ref id="B33">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kikuchi</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Mochizuki</surname>
<given-names>O.</given-names>
</name>
</person-group> (<year>2011</year>). <article-title>Micro-PIV (Micro Particle Image Velocimetry) Visualization of Red Blood Cells (RBCs) Sucked by a Female Mosquito</article-title>. <source>Meas. Sci. Technol.</source> <volume>22</volume>, <fpage>064002</fpage>. <pub-id pub-id-type="doi">10.1088/0957-0233/22/6/064002</pub-id> </citation>
</ref>
<ref id="B34">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Kloostermann</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Poelma</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Westerweel</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2009</year>). &#x201c;<article-title>Accuracy of the Micro-PIV Method for Biological Applications</article-title>. <conf-name>In the proceeding of the 8th International Symposium on PIV</conf-name>, <conf-loc>Melbourne, Victoria, Australia</conf-loc>, <fpage>25</fpage>&#x2013;<lpage>28</lpage>. </citation>
</ref>
<ref id="B35">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Koutsiaris</surname>
<given-names>A. G.</given-names>
</name>
<name>
<surname>Pogiatzi</surname>
<given-names>A.</given-names>
</name>
</person-group> (<year>2004</year>). <article-title>Velocity Pulse Measurements in the Mesenteric Arterioles of Rabbits</article-title>. <source>Physiol. Meas.</source> <volume>25</volume>, <fpage>15</fpage>&#x2013;<lpage>25</lpage>. <pub-id pub-id-type="doi">10.1088/0967-3334/25/1/002</pub-id> </citation>
</ref>
<ref id="B36">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Le Devehat</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Vimeux</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Bondoux</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Khodabandehlou</surname>
<given-names>T.</given-names>
</name>
</person-group> (<year>1990</year>). <article-title>Red Blood Cell Aggregation in Diabetes Mellitus</article-title>. <source>Int. Angiol</source> <volume>9</volume> (<issue>1</issue>), <fpage>11</fpage>&#x2013;<lpage>15</lpage>. </citation>
</ref>
<ref id="B37">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lee</surname>
<given-names>J. Y.</given-names>
</name>
<name>
<surname>Ji</surname>
<given-names>H. S.</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>S. J.</given-names>
</name>
</person-group> (<year>2007</year>). <article-title>Micro-PIV Measurements of Blood Flow in Extraembryonic Blood Vessels of Chicken Embryos</article-title>. <source>Physiol. Meas.</source> <volume>28</volume> (<issue>10</issue>), <fpage>1149</fpage>&#x2013;<lpage>1162</lpage>. <pub-id pub-id-type="doi">10.1088/0967-3334/28/10/002</pub-id> </citation>
</ref>
<ref id="B38">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lee</surname>
<given-names>T. Q.</given-names>
</name>
<name>
<surname>Schmid-Sch&#xf6;nbein</surname>
<given-names>G. W.</given-names>
</name>
<name>
<surname>Zweifach</surname>
<given-names>B. W.</given-names>
</name>
</person-group> (<year>1983</year>). <article-title>The Application of an Improved Dual-Slit Photometric Analyzer for Volumetric Flow Rate Measurements in Microvessels</article-title>. <source>Microvasc. Res.</source> <volume>26</volume> (<issue>3</issue>), <fpage>351</fpage>&#x2013;<lpage>361</lpage>. <pub-id pub-id-type="doi">10.1016/0026-2862(83)90084-5</pub-id> </citation>
</ref>
<ref id="B39">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Levin</surname>
<given-names>G. Y.</given-names>
</name>
<name>
<surname>Egorihina</surname>
<given-names>M. N.</given-names>
</name>
</person-group> (<year>2011</year>). <article-title>Aggregation of Erythrocytes in Burn Disease</article-title>. <source>Int. J. Burns Trauma</source> <volume>1</volume> (<issue>1</issue>), <fpage>34</fpage>&#x2013;<lpage>41</lpage>. <comment>Available at: <ext-link ext-link-type="uri" xlink:href="http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=PMC3415941">http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid&#x3d;PMC3415941</ext-link>
</comment>. </citation>
</ref>
<ref id="B40">
<citation citation-type="web">
<person-group person-group-type="author">
<name>
<surname>Li</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Kang</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2008</year>) <article-title>The Image Stabilizer Plugin for ImageJ</article-title>. <comment>Available at: <ext-link ext-link-type="uri" xlink:href="http://www.cs.cmu.edu/%7Ekangli/code/Image_Stabilizer.html">http://www.cs.cmu.edu/&#x223c;kangli/code/Image_Stabilizer.html</ext-link> (Accessed: 29 July 2021)</comment>. </citation>
</ref>
<ref id="B41">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lima</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Wada</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Takeda</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Tsubota</surname>
<given-names>K.-i.</given-names>
</name>
<name>
<surname>Yamaguchi</surname>
<given-names>T.</given-names>
</name>
</person-group> (<year>2007</year>). <article-title>
<italic>In Vitro</italic> confocal Micro-PIV Measurements of Blood Flow in a Square Microchannel: The Effect of the Haematocrit on Instantaneous Velocity Profiles</article-title>. <source>J. Biomech.</source> <volume>40</volume> (<issue>12</issue>), <fpage>2752</fpage>&#x2013;<lpage>2757</lpage>. <pub-id pub-id-type="doi">10.1016/j.jbiomech.2007.01.012</pub-id> </citation>
</ref>
<ref id="B42">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lima</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Wada</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Tanaka</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Takeda</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Ishikawa</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Tsubota</surname>
<given-names>K.-i.</given-names>
</name>
<etal/>
</person-group> (<year>2008</year>). <article-title>
<italic>In Vitro</italic> blood Flow in a Rectangular PDMS Microchannel: Experimental Observations Using a Confocal Micro-PIV System</article-title>. <source>Biomed. Microdevices</source> <volume>10</volume> (<issue>2</issue>), <fpage>153</fpage>&#x2013;<lpage>167</lpage>. <pub-id pub-id-type="doi">10.1007/s10544-007-9121-z</pub-id> </citation>
</ref>
<ref id="B43">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lima</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Wada</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Tsubota</surname>
<given-names>K.-i.</given-names>
</name>
<name>
<surname>Yamaguchi</surname>
<given-names>T.</given-names>
</name>
</person-group> (<year>2006</year>). <article-title>Confocal Micro-PIV Measurements of Three-Dimensional Profiles of Cell Suspension Flow in a Square Microchannel</article-title>. <source>Meas. Sci. Technol.</source> <volume>17</volume> (<issue>4</issue>), <fpage>797</fpage>&#x2013;<lpage>808</lpage>. <pub-id pub-id-type="doi">10.1088/0957-0233/17/4/026</pub-id> </citation>
</ref>
<ref id="B44">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Long</surname>
<given-names>D. S.</given-names>
</name>
<name>
<surname>Smith</surname>
<given-names>M. L.</given-names>
</name>
<name>
<surname>Pries</surname>
<given-names>A. R.</given-names>
</name>
<name>
<surname>Ley</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Damiano</surname>
<given-names>E. R.</given-names>
</name>
</person-group> (<year>2004</year>). <article-title>Microviscometry Reveals Reduced Blood Viscosity and Altered Shear Rate and Shear Stress Profiles in Microvessels after Hemodilution</article-title>. <source>Proc. Natl. Acad. Sci. U.S.A.</source> <volume>101</volume> (<issue>27</issue>), <fpage>10060</fpage>&#x2013;<lpage>10065</lpage>. <pub-id pub-id-type="doi">10.1073/pnas.0402937101</pub-id> </citation>
</ref>
<ref id="B45">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Luquita</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Urli</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Svetaz</surname>
<given-names>M. J.</given-names>
</name>
<name>
<surname>Gennaro</surname>
<given-names>A. M.</given-names>
</name>
<name>
<surname>Volpintesta</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Palatnik</surname>
<given-names>S.</given-names>
</name>
<etal/>
</person-group> (<year>2009</year>). <article-title>Erythrocyte Aggregation in Rheumatoid Arthritis: Cell and Plasma Factor&#x27;s Role</article-title>. <source>Clin. Hemorheol. Microcirc.</source> <volume>41</volume> (<issue>1</issue>), <fpage>49</fpage>&#x2013;<lpage>56</lpage>. <pub-id pub-id-type="doi">10.3233/CH-2009-1154</pub-id> </citation>
</ref>
<ref id="B46">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mantegazza</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Ungari</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Clavica</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Obrist</surname>
<given-names>D.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Local vs. Global Blood Flow Modulation in Artificial Microvascular Networks: Effects on Red Blood Cell Distribution and Partitioning</article-title>. <source>Front. Physiol.</source> <volume>11</volume>, <fpage>1117</fpage>. <pub-id pub-id-type="doi">10.3389/fphys.2020.566273</pub-id> </citation>
</ref>
<ref id="B47">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Maria</surname>
<given-names>M. S.</given-names>
</name>
<name>
<surname>Chandra</surname>
<given-names>T. S.</given-names>
</name>
<name>
<surname>Sen</surname>
<given-names>A. K.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Capillary Flow-Driven Blood Plasma Separation and On-Chip Analyte Detection in Microfluidic Devices</article-title>. <source>Microfluid Nanofluid</source> <volume>21</volume>, <fpage>1</fpage>&#x2013;<lpage>21</lpage>. <pub-id pub-id-type="doi">10.1007/s10404-017-1907-6</pub-id> </citation>
</ref>
<ref id="B48">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ma&#x161;ka</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Ulman</surname>
<given-names>V.</given-names>
</name>
<name>
<surname>Svoboda</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Matula</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Matula</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Ederra</surname>
<given-names>C.</given-names>
</name>
<etal/>
</person-group> (<year>2014</year>). <article-title>A Benchmark for Comparison of Cell Tracking Algorithms</article-title>. <source>Bioinformatics</source> <volume>30</volume> (<issue>11</issue>), <fpage>1609</fpage>&#x2013;<lpage>1617</lpage>. <pub-id pub-id-type="doi">10.1093/bioinformatics/btu080</pub-id> </citation>
</ref>
<ref id="B49">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Massey</surname>
<given-names>M. J.</given-names>
</name>
<name>
<surname>Shapiro</surname>
<given-names>N. I.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>A Guide to Human <italic>In Vivo</italic> Microcirculatory Flow Image Analysis</article-title>. <source>Crit. Care</source> <volume>20</volume>, <fpage>35</fpage>. <pub-id pub-id-type="doi">10.1186/s13054-016-1213-9</pub-id> </citation>
</ref>
<ref id="B50">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mehri</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Mavriplis</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Fenech</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>Controlled Microfluidic Environment for Dynamic Investigation of Red Blood Cell Aggregation</article-title>. <source>J. Vis. Exp.</source> <volume>2015</volume> (<issue>100</issue>), <fpage>e52719</fpage>. <pub-id pub-id-type="doi">10.3791/52719</pub-id> </citation>
</ref>
<ref id="B51">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mehri</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Mavriplis</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Fenech</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Red Blood Cell Aggregates and Their Effect on Non-newtonian Blood Viscosity at Low Hematocrit in a Two-Fluid Low Shear Rate Microfluidic System</article-title>. <source>PLoS ONE</source> <volume>13</volume> (<issue>7</issue>), <fpage>e0199911</fpage>. <pub-id pub-id-type="doi">10.1371/journal.pone.0199911</pub-id> </citation>
</ref>
<ref id="B52">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Nguyen</surname>
<given-names>C. V.</given-names>
</name>
<name>
<surname>Fouras</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Carberry</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2010</year>). <article-title>Improvement of Measurement Accuracy in Micro PIV by Image Overlapping</article-title>. <source>Exp. Fluids</source> <volume>49</volume> (<issue>3</issue>), <fpage>701</fpage>&#x2013;<lpage>712</lpage>. <pub-id pub-id-type="doi">10.1007/s00348-010-0837-9</pub-id> </citation>
</ref>
<ref id="B53">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Niazi</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>McDonald</surname>
<given-names>J. G.</given-names>
</name>
<name>
<surname>Fenech</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>An Automated Method for Size and Velocity Distribution Measurement in a Particle-Laden Flow</article-title>. <source>Adv. Eng. Softw.</source> <volume>134</volume>, <fpage>10</fpage>&#x2013;<lpage>21</lpage>. <pub-id pub-id-type="doi">10.1016/j.advengsoft.2019.05.002</pub-id> </citation>
</ref>
<ref id="B54">
<citation citation-type="confproc">
<person-group person-group-type="author">
<name>
<surname>Okuda</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Sugii</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Okamoto</surname>
<given-names>K.</given-names>
</name>
</person-group> (<year>2003</year>). &#x201c;<article-title>Velocity Measurement of Blood Flow in a Microtube Using Micro PIV System</article-title>,&#x201d; in <conf-name>In the proceedings of the 4th Pacific Symposium on Flow Visualization and Image Processing</conf-name>, <conf-loc>Chamonix, France</conf-loc>, <fpage>4</fpage>&#x2013;<lpage>7</lpage>. <comment>Available at: <ext-link ext-link-type="uri" xlink:href="http://psfvip4.univ-fcomte.fr/Fpsfvip4/sources/F4084.pdf">http://psfvip4.univ-fcomte.fr/Fpsfvip4/sources/F4084.pdf</ext-link>
</comment>. </citation>
</ref>
<ref id="B55">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Omori</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Imai</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Kikuchi</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Ishikawa</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Yamaguchi</surname>
<given-names>T.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>Hemodynamics in the Microcirculation and in Microfluidics</article-title>. <source>Ann. Biomed. Eng.</source> <volume>43</volume> (<issue>1</issue>), <fpage>238</fpage>&#x2013;<lpage>257</lpage>. <pub-id pub-id-type="doi">10.1007/s10439-014-1180-8</pub-id> </citation>
</ref>
<ref id="B56">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Parrow</surname>
<given-names>N. L.</given-names>
</name>
<name>
<surname>Violet</surname>
<given-names>P.-C.</given-names>
</name>
<name>
<surname>Tu</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Nichols</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Pittman</surname>
<given-names>C. A.</given-names>
</name>
<name>
<surname>Fitzhugh</surname>
<given-names>C.</given-names>
</name>
<etal/>
</person-group> (<year>2018</year>). <article-title>Measuring Deformability and Red Cell Heterogeneity in Blood by Ektacytometry</article-title>. <source>J. Vis. Exp.</source> <volume>2018</volume> (<issue>131</issue>), <fpage>56910</fpage>. <pub-id pub-id-type="doi">10.3791/56910</pub-id> </citation>
</ref>
<ref id="B57">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pasias</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Passos</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Constantinides</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Balabani</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Kaliviotis</surname>
<given-names>E.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Surface Tension Driven Flow of Blood in a Rectangular Microfluidic Channel: Effect of Erythrocyte Aggregation</article-title>. <source>Phys. Fluids</source> <volume>32</volume> (<issue>7</issue>), <fpage>071903</fpage>. <pub-id pub-id-type="doi">10.1063/5.0008939</pub-id> </citation>
</ref>
<ref id="B58">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Passos</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Sherwood</surname>
<given-names>J. M.</given-names>
</name>
<name>
<surname>Kaliviotis</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Agrawal</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Pavesio</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Balabani</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>The Effect of Deformability on the Microscale Flow Behavior of Red Blood Cell Suspensions</article-title>. <source>Phys. Fluids</source> <volume>31</volume> (<issue>9</issue>), <fpage>091903</fpage>. <pub-id pub-id-type="doi">10.1063/1.5111189</pub-id> </citation>
</ref>
<ref id="B59">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Patumraj</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Yoysungnoen</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Kachonrattanadet</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Wirachwong</surname>
<given-names>P.</given-names>
</name>
</person-group> (<year>2005</year>). <article-title>Tumor Neocapillary Density in Hepatocellular Carcinoma Cells Implanted Nude Mice Model</article-title>. <source>Clin. Hemorheol. Microcirc.</source> <volume>33</volume> (<issue>2</issue>), <fpage>137</fpage>&#x2013;<lpage>144</lpage>. </citation>
</ref>
<ref id="B60">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pearson</surname>
<given-names>T. C.</given-names>
</name>
<name>
<surname>Path</surname>
<given-names>F. R. C.</given-names>
</name>
</person-group> (<year>2001</year>). <article-title>Hemorheology in the Erythrocytoses</article-title>. <source>Mt Sinai J. Med.</source> <volume>68</volume> (<issue>3</issue>), <fpage>182</fpage>&#x2013;<lpage>191</lpage>. </citation>
</ref>
<ref id="B61">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pitts</surname>
<given-names>K. L.</given-names>
</name>
<name>
<surname>Fenech</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2013a</year>). <article-title>High Speed versus Pulsed Images for Micro-particle Image Velocimetry: a Direct Comparison of Red Blood Cells versus Fluorescing Tracers as Tracking Particles</article-title>. <source>Physiol. Meas.</source> <volume>34</volume> (<issue>10</issue>), <fpage>1363</fpage>&#x2013;<lpage>1374</lpage>. <pub-id pub-id-type="doi">10.1088/0967-3334/34/10/1363</pub-id> </citation>
</ref>
<ref id="B62">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pitts</surname>
<given-names>K. L.</given-names>
</name>
<name>
<surname>Fenech</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2013b</year>). <article-title>Micro-particle Image Velocimetry for Velocity Profile Measurements of Micro Blood Flows</article-title>. <source>J. Vis. Exp.</source> (<issue>74</issue>), <fpage>e50314</fpage>. <pub-id pub-id-type="doi">10.3791/50314</pub-id> </citation>
</ref>
<ref id="B63">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pitts</surname>
<given-names>K. L.</given-names>
</name>
<name>
<surname>Mehri</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Mavriplis</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Fenech</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2012</year>). <article-title>Micro-particle Image Velocimetry Measurement of Blood Flow: Validation and Analysis of Data Pre-processing and Processing Methods</article-title>. <source>Meas. Sci. Technol.</source> <volume>23</volume> (<issue>10</issue>), <fpage>105302</fpage>. <pub-id pub-id-type="doi">10.1088/0957-0233/23/10/105302</pub-id> </citation>
</ref>
<ref id="B64">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Poelma</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Vennemann</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Lindken</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Westerweel</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2008</year>). <article-title>
<italic>In Vivo</italic> blood Flow and wall Shear Stress Measurements in the Vitelline Network</article-title>. <source>Exp. Fluids</source> <volume>45</volume> (<issue>4</issue>), <fpage>703</fpage>&#x2013;<lpage>713</lpage>. <pub-id pub-id-type="doi">10.1007/s00348-008-0476-6</pub-id> </citation>
</ref>
<ref id="B65">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Raissi</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Perdikaris</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Karniadakis</surname>
<given-names>G. E.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Physics-informed Neural Networks: A Deep Learning Framework for Solving Forward and Inverse Problems Involving Nonlinear Partial Differential Equations</article-title>. <source>J. Comput. Phys.</source> <volume>378</volume>, <fpage>686</fpage>&#x2013;<lpage>707</lpage>. <pub-id pub-id-type="doi">10.1016/j.jcp.2018.10.045</pub-id> </citation>
</ref>
<ref id="B66">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Raissi</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Yazdani</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Karniadakis</surname>
<given-names>G. E.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Hidden Fluid Mechanics: Learning Velocity and Pressure fields from Flow Visualizations</article-title>. <source>Science</source> <volume>367</volume> (<issue>6481</issue>), <fpage>1026</fpage>&#x2013;<lpage>1030</lpage>. <pub-id pub-id-type="doi">10.1126/science.aaw4741</pub-id> </citation>
</ref>
<ref id="B67">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Roman</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Lorthois</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Duru</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Risso</surname>
<given-names>F.</given-names>
</name>
</person-group> (<year>2012a</year>). <article-title>An Optimized Technique for Red Blood Cells Velocity Measurement in Microvessels</article-title>. <source>J. Biomech.</source> <volume>45</volume>, <fpage>S35</fpage>. <pub-id pub-id-type="doi">10.1016/s0021-9290(12)70036-2</pub-id> </citation>
</ref>
<ref id="B68">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Roman</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Lorthois</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Duru</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Risso</surname>
<given-names>F.</given-names>
</name>
</person-group> (<year>2012b</year>). <article-title>Velocimetry of Red Blood Cells in Microvessels by the Dual-Slit Method: Effect of Velocity Gradients</article-title>. <source>Microvasc. Res.</source> <volume>84</volume> (<issue>3</issue>), <fpage>249</fpage>&#x2013;<lpage>261</lpage>. <pub-id pub-id-type="doi">10.1016/j.mvr.2012.08.006</pub-id> </citation>
</ref>
<ref id="B69">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Santiago</surname>
<given-names>J. G.</given-names>
</name>
<name>
<surname>Wereley</surname>
<given-names>S. T.</given-names>
</name>
<name>
<surname>Meinhart</surname>
<given-names>C. D.</given-names>
</name>
<name>
<surname>Beebe</surname>
<given-names>D. J.</given-names>
</name>
<name>
<surname>Adrian</surname>
<given-names>R. J.</given-names>
</name>
</person-group> (<year>1998</year>). <article-title>A Particle Image Velocimetry System for Microfluidics</article-title>. <source>Experiments in Fluids</source> <volume>25</volume> (<issue>4</issue>), <fpage>316</fpage>&#x2013;<lpage>319</lpage>. <pub-id pub-id-type="doi">10.1007/s003480050235</pub-id> </citation>
</ref>
<ref id="B70">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Scharnowski</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>K&#xe4;hler</surname>
<given-names>C. J.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Particle Image Velocimetry - Classical Operating Rules from Today&#x27;s Perspective</article-title>. <source>Opt. Lasers Eng.</source> <volume>135</volume>, <fpage>106185</fpage>. <pub-id pub-id-type="doi">10.1016/j.optlaseng.2020.106185</pub-id> </citation>
</ref>
<ref id="B71">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sebastian</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Dittrich</surname>
<given-names>P. S.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Microfluidics to Mimic Blood Flow in Health and Disease</article-title>. <source>Annu. Rev. Fluid Mech.</source> <volume>50</volume>, <fpage>483</fpage>&#x2013;<lpage>504</lpage>. <pub-id pub-id-type="doi">10.1146/annurev-fluid-010816-060246</pub-id> </citation>
</ref>
<ref id="B72">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Secomb</surname>
<given-names>T. W.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Blood Flow in the Microcirculation</article-title>. <source>Annu. Rev. Fluid Mech.</source> <volume>49</volume>, <fpage>443</fpage>&#x2013;<lpage>461</lpage>. <pub-id pub-id-type="doi">10.1146/annurev-fluid-010816-060302</pub-id> </citation>
</ref>
<ref id="B73">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sharma</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Puniyani</surname>
<given-names>R. R.</given-names>
</name>
<name>
<surname>Bhat</surname>
<given-names>S. V.</given-names>
</name>
<name>
<surname>Advani</surname>
<given-names>S. H.</given-names>
</name>
<name>
<surname>Hegde</surname>
<given-names>U.</given-names>
</name>
<name>
<surname>Rao</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>1992</year>). <article-title>Blood Viscosity Parameter Correlation with Types of Leukemia</article-title>. <source>Physiol. Chem. Phys. Med. NMR</source> <volume>24</volume> (<issue>2</issue>), <fpage>159</fpage>&#x2013;<lpage>164</lpage>. <comment>Available at: <ext-link ext-link-type="uri" xlink:href="https://pubmed.ncbi.nlm.nih.gov/1508991/">https://pubmed.ncbi.nlm.nih.gov/1508991/</ext-link> (Accessed December 13, 2021)</comment>. </citation>
</ref>
<ref id="B74">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sherwood</surname>
<given-names>J. M.</given-names>
</name>
<name>
<surname>Dusting</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Kaliviotis</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Balabani</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2012</year>). <article-title>The Effect of Red Blood Cell Aggregation on Velocity and Cell-Depleted Layer Characteristics of Blood in a Bifurcating Microchannel</article-title>. <source>Biomicrofluidics</source> <volume>6</volume> (<issue>2</issue>), <fpage>024119</fpage>. <pub-id pub-id-type="doi">10.1063/1.4717755</pub-id> </citation>
</ref>
<ref id="B75">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Silva-Herdade</surname>
<given-names>A. S.</given-names>
</name>
<name>
<surname>Andolina</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Faggio</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Calado</surname>
<given-names>&#xc2;.</given-names>
</name>
<name>
<surname>Saldanha</surname>
<given-names>C.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Erythrocyte Deformability - A Partner of the Inflammatory Response</article-title>. <source>Microvasc. Res.</source> <volume>107</volume>, <fpage>34</fpage>&#x2013;<lpage>38</lpage>. <pub-id pub-id-type="doi">10.1016/j.mvr.2016.04.011</pub-id> </citation>
</ref>
<ref id="B76">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sloop</surname>
<given-names>G. D.</given-names>
</name>
<name>
<surname>De Mast</surname>
<given-names>Q.</given-names>
</name>
<name>
<surname>Pop</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Weidman</surname>
<given-names>J. J.</given-names>
</name>
<name>
<surname>St. Cyr</surname>
<given-names>J. A.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>The Role of Blood Viscosity in Infectious Diseases</article-title>. <source>Cureus</source> <volume>12</volume> (<issue>2</issue>), <fpage>e7090</fpage>. <pub-id pub-id-type="doi">10.7759/cureus.7090</pub-id> </citation>
</ref>
<ref id="B77">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sugii</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Nishio</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Okamoto</surname>
<given-names>K.</given-names>
</name>
</person-group> (<year>2002</year>). <article-title>In vivoPIV Measurement of Red Blood Cell Velocity Field in Microvessels Considering Mesentery Motion</article-title>. <source>Physiol. Meas.</source> <volume>23</volume> (<issue>2</issue>), <fpage>403</fpage>&#x2013;<lpage>416</lpage>. <pub-id pub-id-type="doi">10.1088/0967-3334/23/2/315</pub-id> </citation>
</ref>
<ref id="B78">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tinevez</surname>
<given-names>J.-Y.</given-names>
</name>
<name>
<surname>Perry</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Schindelin</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Hoopes</surname>
<given-names>G. M.</given-names>
</name>
<name>
<surname>Reynolds</surname>
<given-names>G. D.</given-names>
</name>
<name>
<surname>Laplantine</surname>
<given-names>E.</given-names>
</name>
<etal/>
</person-group> (<year>2017</year>). <article-title>TrackMate: An Open and Extensible Platform for Single-Particle Tracking</article-title>. <source>Methods</source> <volume>115</volume>, <fpage>80</fpage>&#x2013;<lpage>90</lpage>. <pub-id pub-id-type="doi">10.1016/J.YMETH.2016.09.016</pub-id> </citation>
</ref>
<ref id="B79">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wayland</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Johnson</surname>
<given-names>P. C.</given-names>
</name>
</person-group> (<year>1967</year>). <article-title>Erythrocyte Velocity Measurement in Microvessels by a Two-Slit Photometric Method</article-title>. <source>J. Appl. Physiol.</source> <volume>22</volume> (<issue>2</issue>), <fpage>333</fpage>&#x2013;<lpage>337</lpage>. <pub-id pub-id-type="doi">10.1152/jappl.1967.22.2.333</pub-id> </citation>
</ref>
</ref-list>
</back>
</article>