<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="research-article" dtd-version="2.3" xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Physiol.</journal-id>
<journal-title>Frontiers in Physiology</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Physiol.</abbrev-journal-title>
<issn pub-type="epub">1664-042X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">873049</article-id>
<article-id pub-id-type="doi">10.3389/fphys.2022.873049</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Physiology</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Intracardiac Inverse Potential Mapping Using the Method of Fundamental Solutions</article-title>
<alt-title alt-title-type="left-running-head">Meng et al.</alt-title>
<alt-title alt-title-type="right-running-head">Intracardiac Inverse Potential Mapping</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Meng</surname>
<given-names>Shu</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1328951/overview"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Sunderland</surname>
<given-names>Nicholas</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1713949/overview"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Chamorro-Servent</surname>
<given-names>Judit</given-names>
</name>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Bear</surname>
<given-names>Laura R.</given-names>
</name>
<xref ref-type="aff" rid="aff4">
<sup>4</sup>
</xref>
<xref ref-type="aff" rid="aff5">
<sup>5</sup>
</xref>
<xref ref-type="aff" rid="aff6">
<sup>6</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Lever</surname>
<given-names>Nigel A.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff7">
<sup>7</sup>
</xref>
<xref ref-type="aff" rid="aff8">
<sup>8</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Sands</surname>
<given-names>Gregory B.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1089864/overview"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>LeGrice</surname>
<given-names>Ian J.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff9">
<sup>9</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Gillis</surname>
<given-names>Anne M.</given-names>
</name>
<xref ref-type="aff" rid="aff10">
<sup>10</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/557427/overview"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Zhao</surname>
<given-names>Jichao</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/46448/overview"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Budgett</surname>
<given-names>David M.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Smaill</surname>
<given-names>Bruce H.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
<uri xlink:href="https://loop.frontiersin.org/people/506491/overview"/>
</contrib>
</contrib-group>
<aff id="aff1">
<sup>1</sup>
<institution>Auckland Bioengineering Institute</institution>, <institution>University of Auckland</institution>, <addr-line>Auckland</addr-line>, <country>New Zealand</country>
</aff>
<aff id="aff2">
<sup>2</sup>
<institution>Bristol Heart Institute</institution>, <institution>University of Bristol</institution>, <addr-line>Bristol</addr-line>, <country>United Kingdom</country>
</aff>
<aff id="aff3">
<sup>3</sup>
<institution>Department of Mathematics</institution>, <institution>Universitat Aut&#xf2;noma de Barcelona</institution>, <addr-line>Bellaterra</addr-line>, <country>Spain</country>
</aff>
<aff id="aff4">
<sup>4</sup>
<institution>IHU Liryc, Electrophysiology and Heart Modeling Institute</institution>, <institution>Fondation Bordeaux Universit&#xe9;</institution>, <addr-line>Bordeaux</addr-line>, <country>France</country>
</aff>
<aff id="aff5">
<sup>5</sup>
<institution>Centre de Recherche Cardio-Thoracique de Bordeaux</institution>, <institution>Univ. Bordeaux</institution>, <addr-line>Bordeaux</addr-line>, <country>France</country>
</aff>
<aff id="aff6">
<sup>6</sup>
<institution>Centre de Recherche Cardio-Thoracique de Bordeaux</institution>, <institution>INSERM</institution>, <addr-line>Bordeaux</addr-line>, <country>France</country>
</aff>
<aff id="aff7">
<sup>7</sup>
<institution>Auckland City Hospital</institution>, <addr-line>Auckland</addr-line>, <country>New Zealand</country>
</aff>
<aff id="aff8">
<sup>8</sup>
<institution>Department of Medicine</institution>, <institution>University of Auckland</institution>, <addr-line>Auckland</addr-line>, <country>New Zealand</country>
</aff>
<aff id="aff9">
<sup>9</sup>
<institution>Department of Physiology</institution>, <institution>University of Auckland</institution>, <addr-line>Auckland</addr-line>, <country>New Zealand</country>
</aff>
<aff id="aff10">
<sup>10</sup>
<institution>Libin Cardiovascular Research Institute</institution>, <institution>Calgary University</institution>, <addr-line>Calgary</addr-line>, <addr-line>AB</addr-line>, <country>Canada</country>
</aff>
<author-notes>
<fn fn-type="edited-by">
<p>
<bold>Edited by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/24950/overview">Gernot Plank</ext-link>, Medical University of Graz, Austria</p>
</fn>
<fn fn-type="edited-by">
<p>
<bold>Reviewed by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/240023/overview">Vincent Jacquemet</ext-link>, Universit&#xe9; de Montr&#xe9;al, Canada</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/28348/overview">Peter Michael Van Dam</ext-link>, University Medical Center Utrecht, Netherlands</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/24932/overview">Edward Joseph Vigmond</ext-link>, Universit&#xe9; de Bordeaux, France</p>
</fn>
<corresp id="c001">&#x2a;Correspondence: Bruce H. Smaill, <email>b.smaill@auckland.ac.nz</email>
</corresp>
<fn fn-type="other">
<p>This article was submitted to Cardiac Electrophysiology, a section of the journal Frontiers in Physiology</p>
</fn>
</author-notes>
<pub-date pub-type="epub">
<day>16</day>
<month>05</month>
<year>2022</year>
</pub-date>
<pub-date pub-type="collection">
<year>2022</year>
</pub-date>
<volume>13</volume>
<elocation-id>873049</elocation-id>
<history>
<date date-type="received">
<day>10</day>
<month>02</month>
<year>2022</year>
</date>
<date date-type="accepted">
<day>19</day>
<month>04</month>
<year>2022</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2022 Meng, Sunderland, Chamorro-Servent, Bear, Lever, Sands, LeGrice, Gillis, Zhao, Budgett and Smaill.</copyright-statement>
<copyright-year>2022</copyright-year>
<copyright-holder>Meng, Sunderland, Chamorro-Servent, Bear, Lever, Sands, LeGrice, Gillis, Zhao, Budgett and Smaill</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<p>
<bold>Introduction:</bold> Atrial fibrillation (AF) is the most prevalent cardiac dysrhythmia and percutaneous catheter ablation is widely used to treat it. Panoramic mapping with multi-electrode catheters can identify ablation targets in persistent AF, but is limited by poor contact and inadequate coverage.</p>
<p>
<bold>Objective:</bold> To investigate the accuracy of inverse mapping of endocardial surface potentials from electrograms sampled with noncontact basket catheters.</p>
<p>
<bold>Methods:</bold> Our group has developed a computationally efficient inverse 3D mapping technique using a meshless method that employs the Method of Fundamental Solutions (MFS). An <italic>in-silico</italic> test bed was used to compare ground-truth surface potentials with corresponding inverse maps reconstructed from noncontact potentials sampled with virtual catheters. Ground-truth surface potentials were derived from high-density clinical contact mapping data and computer models.</p>
<p>
<bold>Results:</bold> Solutions of the intracardiac potential inverse problem with the MFS are robust, fast and accurate. Endocardial surface potentials can be faithfully reconstructed from noncontact recordings in real-time if the geometry of cardiac surface and the location of electrodes relative to it are known. Larger catheters with appropriate electrode density are needed to resolve complex reentrant atrial rhythms.</p>
<p>
<bold>Conclusion:</bold> Real-time panoramic potential mapping is feasible with noncontact intracardiac catheters using the MFS.</p>
<p>
<bold>Significance:</bold> Accurate endocardial potential maps can be reconstructed in AF with appropriately designed noncontact multi-electrode catheters.</p>
</abstract>
<kwd-group>
<kwd>atrial arrhythmia</kwd>
<kwd>multi-electrode basket catheters</kwd>
<kwd>method of fundamental solutions</kwd>
<kwd>inverse mapping</kwd>
<kwd>endocardial potentials</kwd>
</kwd-group>
</article-meta>
</front>
<body>
<sec id="s1">
<title>Introduction</title>
<p>Accurate identification of regions in the heart which trigger ectopic activation and sustain reentrant arrhythmia is a critical step in effective interventional treatment of heart rhythm disturbance. Sequential contact mapping with catheters introduced percutaneously into one or more heart chambers is widely used for this purpose (<xref ref-type="bibr" rid="B11">Issa et al., 2019</xref>), but it can be time-consuming and works poorly in atrial fibrillation (AF) where rhythm is non-stationary. While multi-electrode basket catheters have been used for panoramic mapping in AF (<xref ref-type="bibr" rid="B17">Narayan et al., 2012</xref>; <xref ref-type="bibr" rid="B20">Pathik et al., 2018</xref>), it is difficult to position them so that the electrodes are uniformly distributed across the atrial surface and in contact with it (<xref ref-type="bibr" rid="B18">Oesterlein et al., 2016</xref>; <xref ref-type="bibr" rid="B14">Martinez- Mateu et al., 2018</xref>; <xref ref-type="bibr" rid="B20">Pathik et al., 2018</xref>).</p>
<p>In principle, inverse methods can be used to reconstruct potentials on the endocardial surface of a cardiac chamber from electrograms recorded at electrodes that are not in contact with it if three-dimensional (3D) chamber geometry is specified, the locations of electrodes are known and the forward problem, which describes the transfer relationship between measured and endocardial surface potentials, is specified accurately. However, the boundary mesh-based solution methods used previously to solve the intracardiac potential inverse problem have shortcomings that are discussed in detail elsewhere (<xref ref-type="bibr" rid="B15">Meng et al., 2017</xref>; <xref ref-type="bibr" rid="B16">Meng et al., 2022</xref>). With the finite element method (FEM), the transfer matrix is sparse, inherently ill-conditioned and time-consuming to evaluate (<xref ref-type="bibr" rid="B22">Pullan et al., 2005</xref>). On the other hand, boundary elements (BEMs) are not robust for measurement points near the heart wall, particularly when surface topology is complex as is commonly the case with the atria. (<xref ref-type="bibr" rid="B22">Pullan et al., 2005</xref>).</p>
<p>Meshless methods (MMs) employing the Method of Fundamental Solutions (MFS) (<xref ref-type="bibr" rid="B7">Fairweather and Karageorghis, 1998</xref>) have been successfully used to solve the body surface potential inverse problem (<xref ref-type="bibr" rid="B28">Wang and Rudy, 2006</xref>). This approach is computationally efficient and robust in a uniform, isotropic domain, an assumption that is realistic for the intracardiac problem. In this case, the MFS provides an inherently simpler representation of the forward problem than boundary mesh-based methods.</p>
<p>While there have been numerous systematic analyses of the efficacy of inverse body surface potential mapping (<xref ref-type="bibr" rid="B23">Ramanathan and Rudy, 2001</xref>; <xref ref-type="bibr" rid="B5">Cluitmans et al., 2017</xref>; <xref ref-type="bibr" rid="B2">Bear et al., 2018</xref>), there have been very few equivalent studies of intracardiac potential mapping (<xref ref-type="bibr" rid="B16">Meng et al., 2022</xref>) and no attempt to use the MFS in this setting. In the research reported here, we have used the MFS to address the accuracy with which time-varying potentials on the endocardial surface of the left atrium (LA) can be reconstructed from electrograms recorded inside the chamber with basket catheters where the electrodes may or may not be in contact with the atrial wall. We conclude that accurate real-time panoramic potential mapping and 3D phase mapping are feasible with noncontact intracardiac catheters using the MFS. However, to faithfully recover complex potential fields, such as those seen in AF on the endocardial surfaces of the atria, it is necessary to use catheters that are sufficiently large to capture characteristic features of surface potential variation with an electrode distribution appropriate to resolve it spatially (<xref ref-type="bibr" rid="B16">Meng et al., 2022</xref>). We argue that the sampling constraints identified in this study apply to noncontact intracardiac mapping in general.</p>
</sec>
<sec id="s2">
<title>Mathematical Background</title>
<p>Noncontact intracardiac potential mapping seeks to reconstruct the potential distribution on the inner surface of a heart chamber from a discrete set of potentials recorded at known points inside the chamber with a multi-electrode catheter. To solve this inverse problem, it is first necessary to formulate the corresponding forward problem. Here, we extend an approach followed by Wang and Rudy (<xref ref-type="bibr" rid="B28">Wang and Rudy, 2006</xref>), in which the MFS was applied to inverse body surface potential mapping.</p>
<p>The formulation of the intracardiac forward problem is shown in <xref ref-type="fig" rid="F1">Figure 1</xref>. Potentials <inline-formula id="inf1">
<mml:math id="m1">
<mml:mrow>
<mml:mi>&#x3d5;</mml:mi>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="bold">x</mml:mi>
<mml:mtext>c</mml:mtext>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mo>&#xa0;</mml:mo>
</mml:mrow>
</mml:math>
</inline-formula> are recorded at <italic>M</italic> points <inline-formula id="inf2">
<mml:math id="m2">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="bold">x</mml:mi>
<mml:mtext>c</mml:mtext>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> on the surface <italic>&#x393;</italic>
<sub>
<italic>C</italic>
</sub> that bounds the electrodes. A set of <italic>N</italic> fictitious sources is positioned at locations <inline-formula id="inf3">
<mml:math id="m3">
<mml:mrow>
<mml:msubsup>
<mml:mrow>
<mml:mrow>
<mml:mo>{</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi>&#x3be;</mml:mi>
<mml:mi>i</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>}</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>N</mml:mi>
</mml:msubsup>
<mml:mi mathvariant="bold-italic">&#xa0;</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> along a virtual 3D boundary <italic>&#x393;</italic>
<sub>
<italic>V</italic>
</sub> that lies outside the endocardial surface of the cardiac chamber. The linear combination of the Laplace fundamental solution over the sources on <inline-formula id="inf4">
<mml:math id="m4">
<mml:mrow>
<mml:msubsup>
<mml:mrow>
<mml:mrow>
<mml:mo>{</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi>&#x3be;</mml:mi>
<mml:mi>i</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>}</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>N</mml:mi>
</mml:msubsup>
<mml:mi mathvariant="bold-italic">&#xa0;&#xa0;</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> allows us to have an expression of the potentials in the source free volume &#x3a9;<sub>H</sub> contained in the cardiac chamber. It is assumed that 1) there are no electrical sources or sinks within the heart cavity, 2) conductivity throughout the domain is uniform and isotropic, 3) the electrical properties of the basket catheter can be neglected, and 4) bioelectric processes are quasi-static.</p>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption>
<p>Schematic representation of the intracardiac forward problem. Fictitious electrical sources (open circles) distributed around a virtual boundary <inline-formula id="inf5">
<mml:math id="m5">
<mml:mrow>
<mml:msub>
<mml:mtext>&#x393;</mml:mtext>
<mml:mi>V</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> outside the surface <inline-formula id="inf6">
<mml:math id="m6">
<mml:mrow>
<mml:msub>
<mml:mtext>&#x393;</mml:mtext>
<mml:mi>H</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> that bounds a heart cavity <inline-formula id="inf7">
<mml:math id="m7">
<mml:mrow>
<mml:msub>
<mml:mtext>&#x3a9;</mml:mtext>
<mml:mi>H</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> generate current flux within the domain. This contributes to potentials recorded with electrodes (closed circles) on a basket catheter. The electrodes lie on the open surface <inline-formula id="inf8">
<mml:math id="m8">
<mml:mrow>
<mml:msub>
<mml:mtext>&#x393;</mml:mtext>
<mml:mi>C</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>.</p>
</caption>
<graphic xlink:href="fphys-13-873049-g001.tif"/>
</fig>
<p>At any instant, the potential <inline-formula id="inf9">
<mml:math id="m9">
<mml:mrow>
<mml:mi>&#x3d5;</mml:mi>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mi mathvariant="normal">x</mml:mi>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula> at any point <bold>x</bold> in &#x3a9;<sub>H</sub> due to fictitious sources located on the virtual external boundary <inline-formula id="inf10">
<mml:math id="m10">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="italic">&#x393;</mml:mi>
<mml:mi>V</mml:mi>
</mml:msub>
<mml:mo>&#xa0;</mml:mo>
<mml:mo>&#xa0;</mml:mo>
</mml:mrow>
</mml:math>
</inline-formula> is<disp-formula id="e1">
<mml:math id="m11">
<mml:mrow>
<mml:mi>&#x3d5;</mml:mi>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mi mathvariant="bold-italic">x</mml:mi>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mi>a</mml:mi>
<mml:mn>0</mml:mn>
</mml:msub>
<mml:mo>&#x2b;</mml:mo>
<mml:munderover>
<mml:mstyle displaystyle="true">
<mml:mo>&#x2211;</mml:mo>
</mml:mstyle>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>N</mml:mi>
</mml:munderover>
<mml:msub>
<mml:mi>a</mml:mi>
<mml:mi>i</mml:mi>
</mml:msub>
<mml:mi>G</mml:mi>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi>&#x3be;</mml:mi>
<mml:mi>i</mml:mi>
</mml:msub>
<mml:mo>,</mml:mo>
<mml:mi mathvariant="bold-italic">x</mml:mi>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:math>
<label>(1)</label>
</disp-formula>where <inline-formula id="inf11">
<mml:math id="m12">
<mml:mrow>
<mml:msub>
<mml:mi>a</mml:mi>
<mml:mn>0</mml:mn>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is a constant and <inline-formula id="inf12">
<mml:math id="m13">
<mml:mrow>
<mml:mi>a</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi>a</mml:mi>
<mml:mn>1</mml:mn>
</mml:msub>
<mml:mo>,</mml:mo>
<mml:mo>&#x2026;</mml:mo>
<mml:mo>,</mml:mo>
<mml:msub>
<mml:mi>a</mml:mi>
<mml:mi>N</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula> is the instantaneous source current at a source <inline-formula id="inf13">
<mml:math id="m14">
<mml:mrow>
<mml:msubsup>
<mml:mrow>
<mml:mrow>
<mml:mo>{</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi>&#x3be;</mml:mi>
<mml:mi>i</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>}</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>N</mml:mi>
</mml:msubsup>
</mml:mrow>
</mml:math>
</inline-formula>. G is the fundamental solution of the Laplace operator in 3D<disp-formula id="e2">
<mml:math id="m15">
<mml:mrow>
<mml:mi>G</mml:mi>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mi>&#x3be;</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi mathvariant="bold-italic">x</mml:mi>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mn>1</mml:mn>
<mml:mrow>
<mml:mn>4</mml:mn>
<mml:mi>&#x3c0;</mml:mi>
<mml:mrow>
<mml:mo>&#x7c;</mml:mo>
<mml:mrow>
<mml:mi>&#x3be;</mml:mi>
<mml:mo>&#x2212;</mml:mo>
<mml:mi mathvariant="bold-italic">x</mml:mi>
</mml:mrow>
<mml:mo>&#x7c;</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:math>
<label>(2)</label>
</disp-formula>and <inline-formula id="inf14">
<mml:math id="m16">
<mml:mrow>
<mml:msubsup>
<mml:mrow>
<mml:mrow>
<mml:mo>{</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi>&#x3be;</mml:mi>
<mml:mi>i</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>}</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>N</mml:mi>
</mml:msubsup>
</mml:mrow>
</mml:math>
</inline-formula> are the 3D locations of the fictious sources and <inline-formula id="inf15">
<mml:math id="m17">
<mml:mrow>
<mml:mo>&#x7c;</mml:mo>
<mml:mi>&#x3be;</mml:mi>
<mml:mo>&#x2212;</mml:mo>
<mml:mi mathvariant="bold-italic">x</mml:mi>
<mml:mo>&#x7c;</mml:mo>
</mml:mrow>
</mml:math>
</inline-formula> is the Euclidean distance between <bold>x</bold> and <inline-formula id="inf16">
<mml:math id="m18">
<mml:mi>&#x3be;</mml:mi>
</mml:math>
</inline-formula>. Note that <italic>a</italic>
<sub>
<italic>i</italic>
</sub> &#x003D; <italic>&#x03C3;</italic>
<italic>l</italic>
<sub>
<italic>i</italic>
</sub> for <italic>i</italic> &#x003D; 1, <italic>N</italic> where <italic>l</italic>
<sub>
<italic>i</italic>
</sub> is the source current at <italic>&#x3be;</italic>
<sub>
<italic>i</italic>
</sub> and <italic>&#x03C3;</italic> is conductivity.</p>
<p>Potentials at <inline-formula id="inf17">
<mml:math id="m19">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="bold">x</mml:mi>
<mml:mtext>c</mml:mtext>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> on the surface <italic>&#x393;</italic>
<sub>
<italic>C</italic>
</sub> that bounds the electrodes therefore can be estimated by using <xref ref-type="disp-formula" rid="e1">Eq. 1</xref> for <inline-formula id="inf18">
<mml:math id="m20">
<mml:mrow>
<mml:mi mathvariant="normal">x</mml:mi>
<mml:mo>&#x2208;</mml:mo>
<mml:msub>
<mml:mi mathvariant="italic">&#x393;</mml:mi>
<mml:mi>c</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
<italic>.</italic> This results in a linear system of equations when they are equated to the measured potentials on the <italic>M</italic> electrodes of the catheter. It should be noted that while the forward problem has been set up here for the continuous surfaces <italic>&#x393;</italic>
<sub>
<italic>C</italic>
</sub> and <italic>&#x393;</italic>
<sub>
<italic>H</italic>
</sub>, this is not a requirement of the MFS.</p>
<p>Solution of this system yields the associated current source densities on the fictitious external boundary <inline-formula id="inf19">
<mml:math id="m21">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="italic">&#x393;</mml:mi>
<mml:mi>V</mml:mi>
</mml:msub>
<mml:mo>&#xa0;</mml:mo>
</mml:mrow>
</mml:math>
</inline-formula> and corresponding potentials on the endocardial surface <italic>&#x393;</italic>
<sub>
<italic>H</italic>
</sub> are then estimated by using <xref ref-type="disp-formula" rid="e1">Eq. 1</xref> again for <inline-formula id="inf20">
<mml:math id="m22">
<mml:mrow>
<mml:mi mathvariant="normal">x</mml:mi>
<mml:mo>&#x2208;</mml:mo>
<mml:msub>
<mml:mi mathvariant="italic">&#x393;</mml:mi>
<mml:mi>H</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
<italic>.</italic> This system is inherently under-determined because the number of electrodes <italic>M</italic> is generally less than <italic>N</italic>, the number of fictitious sources needed to map potentials faithfully onto <italic>&#x393;</italic>
<sub>
<italic>H</italic>
</sub>.</p>
</sec>
<sec sec-type="methods" id="s3">
<title>Methods</title>
<p>An established computational approach (<xref ref-type="bibr" rid="B23">Ramanathan and Rudy, 2001</xref>) was used to quantify the accuracy of inverse potential mapping and key steps are illustrated in <xref ref-type="fig" rid="F2">Figure 2</xref>. First, ground-truth potential distributions were specified on the endocardial surface of the left atrium (LA). The associated field throughout the LA was determined by numerical solution of Laplace&#x2019;s equation and potentials were sampled at points corresponding to electrode locations on open basket catheters with different electrode distributions across a range of dimensions (<xref ref-type="fig" rid="F2">Figure 2A</xref>). Endocardial surface potentials were then reconstructed from the sampled potentials using the MFS (<xref ref-type="fig" rid="F2">Figure 2B</xref>) and compared with ground-truth potential distributions. This process was continued through a complete atrial activation cycle for stationary rhythms or over several cycles of reentrant activity. Ground-truth electrograms were also compared with corresponding inverse estimates at points across the endocardial surface (<xref ref-type="fig" rid="F2">Figure 2F</xref>) to assess the accuracy with which local activation timing information is reconstructed.</p>
<fig id="F2" position="float">
<label>FIGURE 2</label>
<caption>
<p>
<italic>In silico</italic> analysis of the effects of mapping catheter dimension and electrode distribution on MFS inverse solutions during pacing from distal coronary sinus. Ground-truth LA surface potential distributions during atrial activation are constructed from pace-synchronized contact recordings acquired with a high density electrode array. Corresponding potential fields in the LA cavity are estimated throughout the atrial activation cycle and &#x201c;sampled&#x201d; at locations of virtual basket catheter electrodes. Inverse surface potential maps are then reconstructed from these data and compared with ground truth maps. <bold>(A)</bold> Ground-truth LA surface potential distribution at one instant during activation - see red line in <bold>(C)</bold>. Corresponding inverse potential map <bold>(B)</bold> reconstructed from potentials sampled with virtual 64-electrode basket catheter with 0.67 volume fraction relative to LA. Electrodes are distributed uniformly along 8 splines as indicated in <bold>(A)</bold>. <bold>(C)</bold> Ground truth and reconstructed electrograms at 1 in <bold>(A,B)</bold>. In the middle panel, CC <bold>(D)</bold>, nRMSE <bold>(E)</bold> and &#x394;T <bold>(F)</bold> are presented as functions of relative catheter volume for inverse solutions over one activation cycle. Median values and IQR are given for inverse maps constructed from &#x201c;recordings&#x201d; at 64 sites (blue) and 3 sequential &#x201c;recordings&#x201d; at 64 sites following stepwise rotation of the catheter through 15&#xb0; around its axis (red). Both maps in the lower panel relate to the same time as in <bold>(A,B)</bold>. In <bold>(G)</bold>, the distribution of nRMSE on the LA surface is compared with spline location for a potential map constructed from 64 full or near-contact &#x201c;recordings&#x201d;, while <bold>(H)</bold> corresponds to <bold>(B)</bold>. Here, the inverse map was constructed from 3 sequential &#x201c;recordings&#x201d; at 64 sites with a relative catheter volume fraction of 0.67. <bold>(I)</bold> Ground truth and inverse electrograms at 2) in <bold>(H)</bold>. Abbreviations: MFS, Method of Fundamental Solutions; LA, left atrium; CC, correlation coefficient; nRMSE, normalized root-mean-squared error; &#x394;T, activation time difference; IQR, interquartile range.</p>
</caption>
<graphic xlink:href="fphys-13-873049-g002.tif"/>
</fig>
<p>Clinical ground truth data used in this study were acquired as follows. CT imaging was performed in one patient undergoing catheter ablation to treat atrial flutter. The patient gave written informed consent and the study protocol was approved by the Melbourne Health Research and Human Ethics Committee. LA geometry was segmented with the Ensite Verismo<sup>TM</sup> tool and registered with respect to the mapping system (Ensite Precision, Abbott). A decapolar pacing catheter was positioned in the coronary sinus (CS). A 20-pole Lasso<sup>TM</sup> catheter was introduced into the LA <italic>via</italic> trans-septal puncture and used to collect 3,200 time-referenced, spatially-registered contact unipolar electrograms across the LA during pacing (300&#xa0;ms interval) from the distal CS at a sampling rate of 1&#xa0;kHz. The LA shell was refined to 5,000 vertices and potentials were interpolated by Dirichlet energy minimization (<xref ref-type="bibr" rid="B3">Botsch et al., 2010</xref>).</p>
<p>Ground truth data representing polymorphic reentrant atrial activation were simulated. Atrial surface geometry was reconstructed in an anaesthetized sheep (crossbred female, 53&#xa0;Kg). All procedures were approved by the Animal Ethics Committee of the University of Auckland and conform to the Guide for the Care and Use of Laboratory Animals (National Institutes of Health publication no. 85-23). Gadolinium-enhanced ECG-gated MRI images of the atria (1.0 &#xd7; 1.0&#xa0;mm<sup>2</sup> in-plane resolution approximately parallel to the atrio-ventricular valve plane and 1.6&#xa0;mm between slices) were acquired with a 3T Siemens Magnetom Skyra<sup>TM</sup> scanner. LA endocardial surface geometry was segmented using Amira (Thermo Fisher Scientific) and a 3D triangular surface mesh (1,529 nodes) was fitted to the LA with pulmonary veins and left atrial appendage truncated. Ground-truth potential distributions representing polymorphic reentrant atrial activation were modeled on this geometry as follows. Meandering spiral wave reentry was simulated on an isotropic 2D monodomain with Fenton Karma activation kinetics (<xref ref-type="bibr" rid="B8">Fenton and Karma, 1998</xref>) using a standard cross-field S1-S2 stimulus protocol (<xref ref-type="bibr" rid="B19">Pandit et al., 2005</xref>). Points on the 2D domain were sampled and mapped onto the 3D surface mesh so that surface area was similar in both, with a contour adjacent to the boundary in the former assigned to the mitral valve orifice. Extracellular potentials were approximated from the transmembrane currents computed at each 3D point at a sampling rate of 1&#xa0;kHz (<xref ref-type="sec" rid="s13">Supplementary Video S1</xref>&#x2014;Simulated ground truth data&#x2014;in the <xref ref-type="sec" rid="s13">Supplementary Material</xref>).</p>
<p>The open-source software environment SCIRun (<ext-link ext-link-type="uri" xlink:href="http://www.sci.utah.edu/cibc-software/scirun.html">http://www.sci.utah.edu/cibc-software/scirun.html</ext-link>) was used for FEM solutions of the 3D forward problem. (<xref ref-type="bibr" rid="B4">Burton et al., 2011</xref>). Intracardiac potential fields were computed from the ground-truth surface potential distributions at successive time instants by solving Laplace&#x2019;s equation throughout <inline-formula id="inf21">
<mml:math id="m23">
<mml:mrow>
<mml:mi mathvariant="bold-italic">&#xa0;</mml:mi>
<mml:msub>
<mml:mi>&#x3a9;</mml:mi>
<mml:mi>H</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>. The intracardiac field was sampled at points corresponding to electrodes on two basket catheter configurations with 1) 64 channels with 8 equally spaced electrodes along 8 splines at equal radial angles, and 2) 130 channels with 8 equally spaced electrodes along 16 splines at equal radial angles and electrodes at upper and lower poles. Basket dimensions were uniformly scaled to vary catheter:atrial volume ratio. The centroids of catheters and the LA chamber were aligned to allow maximum catheter expansion and to ensure reproducibility between results. Noise was imposed by adding Gaussian noise independently to the electrograms recorded at each electrode with power set at realistic levels. Signal-to-noise ratio (SNR) is quantified as the ratio of root-mean-squared (RMS) voltages of reconstructed electrograms and noise.</p>
<p>Inverse solutions with the MFS were run with purpose-written code. The fictitious boundary was formed by uniform scaling of the atrial surface mesh and sources were associated with each node. Inflation was quantified as the relative volume difference between <italic>&#x393;</italic>
<sub>
<italic>V</italic>
</sub> and <italic>&#x393;</italic>
<sub>
<italic>H</italic>
</sub>
<italic>.</italic> Solutions were stable across the inflation range 2&#x2013;10% (<xref ref-type="sec" rid="s13">Supplementary Figure S1</xref>) and the value 6% was selected as optimal in the results presented here. Inverse endocardial potential distributions for intracardiac potentials &#x201c;sampled&#x201d; with virtual catheters were obtained using zero-order Tikhonov regularization (<xref ref-type="bibr" rid="B27">Tikhonov and Arsenin, 1977</xref>) employing the L-curve method to calculate the regularization parameter (<xref ref-type="bibr" rid="B10">Hansen, 2010</xref>).</p>
<p>Phase maps were constructed using the approach outlined by Kuklik et al. (<xref ref-type="bibr" rid="B12">Kuklik et al., 2017</xref>) Sinusoidal recomposition was applied to electrograms at each LA surface node and the Hilbert transformation was then used to estimate instantaneous phase at these points.</p>
<p>Correspondence between ground-truth and reconstructed potential maps were quantified by evaluating normalized RMS error (nRMSE) and correlation coefficient (CC).<disp-formula id="e3">
<mml:math id="m24">
<mml:mrow>
<mml:mi>n</mml:mi>
<mml:mi>R</mml:mi>
<mml:mi>M</mml:mi>
<mml:mi>S</mml:mi>
<mml:mi>E</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mi mathvariant="bold-italic">&#xa0;</mml:mi>
<mml:msqrt>
<mml:mrow>
<mml:mfrac>
<mml:mrow>
<mml:mstyle displaystyle="true">
<mml:msubsup>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>N</mml:mi>
</mml:msubsup>
<mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msubsup>
<mml:mo>&#x2205;</mml:mo>
<mml:mrow>
<mml:mi>G</mml:mi>
<mml:mi>T</mml:mi>
</mml:mrow>
<mml:mi>i</mml:mi>
</mml:msubsup>
<mml:mo>&#x2212;</mml:mo>
<mml:mo>&#xa0;</mml:mo>
<mml:msubsup>
<mml:mo>&#x2205;</mml:mo>
<mml:mi>R</mml:mi>
<mml:mi>i</mml:mi>
</mml:msubsup>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msup>
</mml:mrow>
</mml:mstyle>
</mml:mrow>
<mml:mrow>
<mml:mstyle displaystyle="true">
<mml:msubsup>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>N</mml:mi>
</mml:msubsup>
<mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msubsup>
<mml:mo>&#x2205;</mml:mo>
<mml:mrow>
<mml:mi>G</mml:mi>
<mml:mi>T</mml:mi>
</mml:mrow>
<mml:mi>i</mml:mi>
</mml:msubsup>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msup>
</mml:mrow>
</mml:mstyle>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:msqrt>
<mml:mtext>&#x2009;</mml:mtext>
<mml:mi mathvariant="normal">and</mml:mi>
<mml:mtext>&#x2009;</mml:mtext>
<mml:mi mathvariant="bold-italic">&#xa0;</mml:mi>
<mml:mi>C</mml:mi>
<mml:mi>C</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mo>&#xa0;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mstyle displaystyle="true">
<mml:msubsup>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>N</mml:mi>
</mml:msubsup>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msubsup>
<mml:mo>&#x2205;</mml:mo>
<mml:mrow>
<mml:mi>G</mml:mi>
<mml:mi>T</mml:mi>
</mml:mrow>
<mml:mi>i</mml:mi>
</mml:msubsup>
<mml:mo>&#x2212;</mml:mo>
<mml:mo>&#xa0;</mml:mo>
<mml:msub>
<mml:mi>&#x3bc;</mml:mi>
<mml:mrow>
<mml:mi>G</mml:mi>
<mml:mi>T</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:mstyle>
<mml:mstyle displaystyle="true">
<mml:msubsup>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>N</mml:mi>
</mml:msubsup>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msubsup>
<mml:mo>&#x2205;</mml:mo>
<mml:mi>R</mml:mi>
<mml:mi>i</mml:mi>
</mml:msubsup>
<mml:mo>&#x2212;</mml:mo>
<mml:mo>&#xa0;</mml:mo>
<mml:msub>
<mml:mi>&#x3bc;</mml:mi>
<mml:mi>R</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:mstyle>
</mml:mrow>
<mml:mrow>
<mml:msqrt>
<mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mstyle displaystyle="true">
<mml:msubsup>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>N</mml:mi>
</mml:msubsup>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msubsup>
<mml:mo>&#x2205;</mml:mo>
<mml:mrow>
<mml:mi>G</mml:mi>
<mml:mi>T</mml:mi>
</mml:mrow>
<mml:mi>i</mml:mi>
</mml:msubsup>
<mml:mo>&#x2212;</mml:mo>
<mml:mo>&#xa0;</mml:mo>
<mml:msub>
<mml:mi>&#x3bc;</mml:mi>
<mml:mrow>
<mml:mi>G</mml:mi>
<mml:mi>T</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:mstyle>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msup>
</mml:mrow>
</mml:msqrt>
<mml:msqrt>
<mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mstyle displaystyle="true">
<mml:msubsup>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>N</mml:mi>
</mml:msubsup>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msubsup>
<mml:mo>&#x2205;</mml:mo>
<mml:mi>R</mml:mi>
<mml:mi>i</mml:mi>
</mml:msubsup>
<mml:mo>&#x2212;</mml:mo>
<mml:mo>&#xa0;</mml:mo>
<mml:msub>
<mml:mi>&#x3bc;</mml:mi>
<mml:mi>R</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:mstyle>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msup>
</mml:mrow>
</mml:msqrt>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:math>
<label>(3)</label>
</disp-formula>where <italic>N</italic> is the number of surface points compared, <inline-formula id="inf22">
<mml:math id="m25">
<mml:mrow>
<mml:msubsup>
<mml:mo>&#x2205;</mml:mo>
<mml:mrow>
<mml:mi>G</mml:mi>
<mml:mi>T</mml:mi>
</mml:mrow>
<mml:mi>i</mml:mi>
</mml:msubsup>
</mml:mrow>
</mml:math>
</inline-formula> and <inline-formula id="inf23">
<mml:math id="m26">
<mml:mrow>
<mml:msubsup>
<mml:mo>&#x2205;</mml:mo>
<mml:mi>R</mml:mi>
<mml:mi>i</mml:mi>
</mml:msubsup>
</mml:mrow>
</mml:math>
</inline-formula> are ground-truth and reconstructed potentials at surface point <italic>i</italic>, and <inline-formula id="inf24">
<mml:math id="m27">
<mml:mrow>
<mml:msub>
<mml:mi>&#x3bc;</mml:mi>
<mml:mrow>
<mml:mi>G</mml:mi>
<mml:mi>T</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#xa0;</mml:mo>
</mml:mrow>
</mml:math>
</inline-formula> and <inline-formula id="inf25">
<mml:math id="m28">
<mml:mrow>
<mml:msub>
<mml:mi>&#x3bc;</mml:mi>
<mml:mi>R</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> are mean values for ground-truth and reconstructed potentials, respectively, across the surface.</p>
<p>Activation times (ATs) for ground-truth (AT<sub>GT</sub>) and reconstructed electrograms (AT<sub>R</sub>) were estimated as maximum negative rate of potential change and the activation time difference &#x394;T at each surface point was evaluated as<disp-formula id="e4">
<mml:math id="m29">
<mml:mrow>
<mml:mi mathvariant="italic">&#x394;</mml:mi>
<mml:mi>T</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mrow>
<mml:mo>&#x7c;</mml:mo>
<mml:mrow>
<mml:mi>A</mml:mi>
<mml:msub>
<mml:mi>T</mml:mi>
<mml:mrow>
<mml:mi>G</mml:mi>
<mml:mi>T</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>A</mml:mi>
<mml:msub>
<mml:mi>T</mml:mi>
<mml:mi>R</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>&#x7c;</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:math>
<label>(4)</label>
</disp-formula>
</p>
<p>Programs were written in C or in the MATLAB programming language (The Mathworks, Natick, Massachusetts).</p>
</sec>
<sec sec-type="results" id="s4">
<title>Results</title>
<sec id="s4-1">
<title>Inverse Potential Mapping in Stationary Rhythm</title>
<p>
<xref ref-type="fig" rid="F2">Figure 2</xref> indicates the accuracy with which high-density potential maps can be reconstructed from clinical ground truth electrograms recorded during the relatively uniform spread of LA activation in coronary sinus pacing. Key features of activation were reconstructed from intra-atrial potentials sampled with a virtual 64-electrode noncontact catheter that occupied &#x223c;67% of atrial cavity volume (<xref ref-type="fig" rid="F2">Figure 2A</xref>). However, neither high resolution features of instantaneous potential maps (<xref ref-type="fig" rid="F2">Figure 2B</xref>) nor high frequency components of regional electrograms (<xref ref-type="fig" rid="F2">Figure 2F</xref>) were captured faithfully. Despite this, accuracy measures were high and surprisingly stable across a wide range of catheter dimensions with median CC &#x3d; 0.92, nRMSE &#x3d; 0.054 and &#x394;T &#x3d; 1&#xa0;ms for catheter:atrial volume ratios &#x3e;0.3 with a 64-electrode basket catheter (<xref ref-type="fig" rid="F2">Figures 2D&#x2013;F</xref>). None of these measures improved with full or near contact between electrodes and endocardial surface, and nRMSE was highest between splines where the spacing of adjacent electrodes was greatest (<xref ref-type="fig" rid="F2">Figure 2H</xref>), indicating that spatial distribution of electrodes on the surface that bounds the catheter is the problem here. Sampling density was increased by moving the catheter and synchronizing the electrograms acquired. The instantaneous potential map in <xref ref-type="fig" rid="F2">Figure 2C</xref> was reconstructed from 192 electrograms &#x201c;recorded&#x201d; in 3 sequential steps by rotating the virtual 64-electrode catheter (relative volume ratio 0.67) around its axis in increments of 15&#xb0;. This markedly improved the match between high-density ground truth and inverse maps (compare <xref ref-type="fig" rid="F2">Figures 2A,C</xref>). The nRMSE between electrodes was substantially reduced (compare <xref ref-type="fig" rid="F2">Figures 2H,I</xref>) and high frequency components of complex local electrograms were reconstructed accurately (<xref ref-type="fig" rid="F2">Figure 2F</xref>). Median CC increased to &#x223c;0.97 and median nRMSE halved across a wide range of catheter dimensions (<xref ref-type="fig" rid="F2">Figure 2G</xref>).</p>
</sec>
<sec id="s4-2">
<title>Inverse Potential Mapping in Reentrant Rhythm</title>
<p>In <xref ref-type="fig" rid="F3">Figure 3</xref>, we present the effects of catheter dimension and electrode distribution on inverse solutions obtained with the MFS in simulated macroscopic reentrant activation of the LA that replicates features of atrial flutter. Catheter designs considered are a 64-electrode catheter with 8 uniformly spaced electrodes along 8 splines and a 130-electrode catheter that has 8 uniformly distributed electrodes on 16 splines with 2 additional polar electrodes. Once again, the centroids of catheters and LA chamber were aligned.</p>
<fig id="F3" position="float">
<label>FIGURE 3</label>
<caption>
<p>Effects of mapping catheter electrode distribution on inverse solutions with MFS during macro reentry. LA surface potentials throughout 3 activation cycles in simulated atrial flutter are reconstructed from electrograms sampled inside the LA cavity with 64- and 130-electrode basket catheters and compared with ground-truth surface potentials. The upper panel presents typical results for catheters that bound a volume fraction of 0.67 relative to LA volume. These include <bold>(A)</bold> the ground-truth surface potential distribution at one instant during reentrant activation and corresponding potential maps reconstructed using electrograms sampled with <bold>(B)</bold> a 64- electrode basket catheter, and <bold>(C)</bold> a 130-electrode basket catheter. In the lower panel CC <bold>(D)</bold>, nRMSE <bold>(E)</bold> and &#x394;T <bold>(F)</bold> are presented as functions of relative catheter volume for the 64-electrode catheter (blue) and 130-electrode catheter (red). Median values and IQR are given. Abbreviations: MFS, Method of Fundamental Solutions; LA, left atrium; CC, correlation coefficient; nRMSE, normalized root-mean-squared error; &#x394;T, activation time difference; IQR, interquartile range.</p>
</caption>
<graphic xlink:href="fphys-13-873049-g003.tif"/>
</fig>
<p>In the upper panel of <xref ref-type="fig" rid="F3">Figure 3</xref>, an instantaneous ground-truth potential map (<xref ref-type="fig" rid="F3">Figure 3A</xref>) is compared with corresponding inverse maps constructed from potentials sampled with a 64-electrode catheter (<xref ref-type="fig" rid="F3">Figure 3B</xref>) and a 130-electrode catheter (<xref ref-type="fig" rid="F3">Figure 3C</xref>). Endocardial potentials were poorly reconstructed in some regions of the LA with an 8 spline 64-electrode basket catheter but recovered more faithfully with a 16 spline 130-electrode catheter where electrode distribution is more uniform, spatially. As might be expected, errors with the 64-electrode catheter were greatest between splines near the equator where inter-electrode spacing was largest.</p>
<p>The correspondence between ground-truth and reconstructed surface electrograms was quantified for these two catheters over 3 consecutive activation cycles for a range of catheter dimensions, and results are presented in the lower panel of <xref ref-type="fig" rid="F3">Figure 3</xref>. The accuracy with which unanchored reentrant rhythm could be reconstructed was consistently less than for more stable paced rhythms (compare <xref ref-type="fig" rid="F3">Figure 3</xref> with <xref ref-type="fig" rid="F2">Figure 2</xref>) and it was affected more markedly by relative catheter dimensions. For each of the 3 metrics considered, performance was better at all catheter dimensions with 130-electrode catheters than with the 64-electrode catheters. For example, with 130-electrode catheters, CC approached a median of 0.97 [IQR 0.07] as catheter dimensions were increased, compared with corresponding values around 0.9 [IQR 0.19] with 64-electrode catheters (<xref ref-type="fig" rid="F3">Figure 3D</xref>). Consistent with these results, nRMSE was reduced with increased catheter dimension reaching a median of 0.042 [IQR 0.055] for the 130-electrode catheter compared with 0.083 [IQR 0.099] for 64-electrode catheters (<xref ref-type="fig" rid="F3">Figure 3E</xref>). Finally, &#x394;T was reduced to a median of 1&#xa0;ms with a 130-electrode catheter compared with 2&#xa0;ms for 64-electrode catheters (<xref ref-type="fig" rid="F3">Figure 3F</xref>). All three metrics were relatively stable for catheter volumes &#x3e;0.6 relative to LA volume.</p>
</sec>
<sec id="s4-3">
<title>Effects of Noise on Inverse Potential Mapping</title>
<p>The effects of noise on the accuracy of inverse endocardial potentials reconstructed with the MFS are summarized in <xref ref-type="fig" rid="F4">Figure 4</xref>. Intra-atrial electrograms were &#x201c;sampled&#x201d; with 130-channel catheters during simulated macro-reentry with superimposed Gaussian noise at RMS voltages of 18, 56 and 178&#xa0;&#xb5;V. In general, addition of noise had little effect for catheter: LA volume ratios &#x3e;0.5. However, inverse solutions were progressively degraded by noise at catheter volumes less than this (<xref ref-type="fig" rid="F4">Figures 4B&#x2013;D</xref>). Comparison of the representative electrograms in <xref ref-type="fig" rid="F4">Figure 4A</xref> provides further insight into this finding. While SNR in reconstructed electrograms scales inversely with added noise, it is much worse for the smaller of the two catheters (6.54, 4.23 and 1.91 for RMS noise voltages of 18, 56 and 178&#xa0;&#x3bc;V, respectively, compared with 69.56, 22.85 and 6.83 for the larger catheter). It is also noteworthy that while our inverse solutions do not recover higher frequency components in the ground truth electrograms when the catheter is small this is not systematically altered by noise.</p>
<fig id="F4" position="float">
<label>FIGURE 4</label>
<caption>
<p>Effects of noise on inverse solutions with the MFS during macro reentry. LA surface potentials throughout activation cycle in simulated atrial flutter are reconstructed from electrograms sampled inside the LA cavity using 130-electrode basket catheters with added Gaussian noise at different mean power levels. All data are compared with ground-truth endocardial potentials. In the upper panel <bold>(A)</bold> electrograms reconstructed from records acquired from a very small and a large basket catheter with 18, 56 and 178&#xa0;&#x03BC;V of added noise are presented with the corresponding ground-truth electrogram. Catheter volumes relative to LA volume are 0.014 and 0.91, respectively. In the lower panel, CC <bold>(B)</bold>, nRMSE <bold>(C)</bold> and &#x394;T <bold>(D)</bold> are presented as functions of relative catheter volume for the three noise levels. Median values and IQR are given. Abbreviations: LA, left atrium; CC, correlation coefficient; nRMSE, normalized root-mean-squared error; &#x394;T, activation time difference.</p>
</caption>
<graphic xlink:href="fphys-13-873049-g004.tif"/>
</fig>
</sec>
<sec id="s4-4">
<title>Inverse Phase Mapping in Macroscopic Reentry</title>
<p>While potential maps during macro reentrant activity were reconstructed more faithfully using a 130-electrode catheter than a 64-electrode catheter with the same dimension, corresponding phase maps in <xref ref-type="fig" rid="F5">Figure 5A</xref> appear to carry very similar information about the history of activation across the LA surface. This similarity in phase distribution was preserved throughout an extended sequence of simulated electrical activity (<xref ref-type="sec" rid="s13">Supplementary Video S1</xref>), where phase singularities identified recovered with 64- and 130-electrode catheters are also collocated. The correspondence with ground truth for phase maps obtained with noncontact catheters was maintained for a wider range of relative catheter volumes than for the potential maps in <xref ref-type="fig" rid="F3">Figure 3</xref> above. However, CC was increased and nRMSE reduced with a 130-electrode catheter compared to a 64-electrode catheter (<xref ref-type="fig" rid="F5">Figure 5B</xref>). This indicates that phase maps with the latter capture key features of wave front propagation in macro reentrant arrhythmia, but aspects of the fine structure of the phase distribution are lost.</p>
<fig id="F5" position="float">
<label>FIGURE 5</label>
<caption>
<p>Phase maps of inverse solutions with MFS during macro-reentry. LA surface potentials throughout activation cycle in simulated atrial flutter are reconstructed from electrograms sampled inside the LA cavity using 64- and 130-electrode basket catheters. The centrally located catheters occupy 67% of LA volume. <bold>(A)</bold> Ground truth phase map at one instant during activation compared with corresponding phase maps for surface potentials reconstructed from electrograms recorded with 64-electrode and 130-electrode basket catheters. <bold>(B)</bold> CC and nRMSE presented as functions of relative catheter volume for the 64-electrode catheter (blue) and 130-electrode catheter (red). Median values and IQR are given. Abbreviations: MFS, Method of Fundamental Solutions; LA, left atrium; CC, correlation coefficient; nRMSE, normalized root-mean-squared error; IQR, interquartile range.</p>
</caption>
<graphic xlink:href="fphys-13-873049-g005.tif"/>
</fig>
</sec>
<sec id="s4-5">
<title>Region-Of-Interest Potential Mapping</title>
<p>With region-of-interest (RoI) mapping, a small catheter is positioned close to a region of the endocardial surface to reconstruct local electrical activity. In <xref ref-type="fig" rid="F6">Figure 6</xref>, we consider the accuracy with which regional electrical activity can be recovered using non-contact catheters. This analysis was completed without adding Gaussian noise. An 8-spline 64-electrode basket catheter (major and minor axes 25 and 23&#xa0;mm, respectively) was initially located close to the origin of a simulated macro-reentrant circuit in the LA (<xref ref-type="fig" rid="F6">Figure 6A</xref>). The inverse solution (<xref ref-type="fig" rid="F6">Figure 6B</xref>) was good near the catheter, but much poorer over the rest of the LA. This is demonstrated in <xref ref-type="fig" rid="F6">Figure 6C</xref> where CC is rendered on the LA surface; median CC is &#x3e;0.9 in the RoI, but falls off rapidly with distance from this region. In the lower panel we present CC (<xref ref-type="fig" rid="F6">Figure 6D</xref>), nRMSE (<xref ref-type="fig" rid="F6">Figure 6E</xref>) and &#x394;T (<xref ref-type="fig" rid="F6">Figure 6F</xref>) in the RoI (red) and across the full endocardial surface (blue) for inverse solutions constructed as the catheter was moved progressively along a line from the origin of the LAA to the inter-atrial septum (<xref ref-type="fig" rid="F6">Figure 6A</xref>). These figures demonstrate that regional mapping performance was excellent when the catheter was in or adjacent to the RoI, but poor when the catheter was most distant from it. Global mapping performance was best when the catheter was located centrally, but significantly poorer in this case in the RoI. Of particular interest, RoI performance was optimal when the catheter was &#x223c;10&#xa0;mm from its initial position with electrodes 9&#x2013;20&#xa0;mm from the LA wall; median CC was 0.96 [IQR 0.072], median nRMSE 0.09 [IQR 0.05] and median &#x394;T 0.89&#xa0;ms [IQR 1.97&#xa0;ms].</p>
<fig id="F6" position="float">
<label>FIGURE 6</label>
<caption>
<p>Comparison of region-of-interest inverse potential mapping with global mapping. LA surface potentials during 3 activation cycles of simulated macroscopic reentry were reconstructed from electrograms sampled inside the LA cavity with a small 64-electrode basket catheter. The catheter was initially positioned with some electrodes touching the wall at the junction with the LAA and then moved rightward until electrodes made contact with the inter-atrial septum. <bold>(A)</bold> Representative ground truth potentials on cavity surface also showing broken white line along which catheter is moved from origin of LAA (relative catheter position 0) to inter-atrial septum (relative catheter position 1). <bold>(B)</bold> Inverse solution reconstructed from potentials sampled at relative catheter position 0. <bold>(C)</bold> Correlation coefficient map for ground-truth and inverse solutions in this case. The RoI indicated is the smoothed boundary of the surface in <bold>(C)</bold> where CC &#x2265; 0.9. In the lower panel <bold>(D&#x2013;F)</bold> present CC, nRMSE and &#x394;T, respectively, in the RoI (red) and across the complete LA surface (blue) for inverse solutions with the catheter at equi-spaced locations along the line in <bold>(A)</bold>; catheter locations 0 and 1 are indicated in <bold>(A)</bold>. Median values and interquartile range (IQR) are given in lower panel. Abbreviations: RoI, region of interest; LA, left atrium; LAA, left atrial appendage; CC, correlation coefficient; nRMSE, normalized.</p>
</caption>
<graphic xlink:href="fphys-13-873049-g006.tif"/>
</fig>
</sec>
</sec>
<sec sec-type="discussion" id="s5">
<title>Discussion</title>
<sec id="s5-1">
<title>Summary</title>
<p>This analysis of noncontact intracardiac potential mapping extends an <italic>in-silico</italic> boundary mesh-based study previously reported by our laboratory (<xref ref-type="bibr" rid="B15">Meng et al., 2017</xref>; <xref ref-type="bibr" rid="B16">Meng et al., 2022</xref>). Here we have investigated the accuracy with which endocardial potential maps can be reconstructed from noncontact electrograms recorded with a multi-electrode basket catheter using meshless methods that use the MFS, the first time that this has been done as far as we are aware. We demonstrate that fast, accurate noncontact potential mapping and phase mapping are possible using this approach. However, the spatial frequency of the electrical activity captured is determined by the distribution of electrodes and in order to recover complex non-stationary rhythms, such as AF, the mapping catheter must address a representative subvolume of the cardiac chamber.</p>
</sec>
<sec id="s5-2">
<title>Effects of Catheter Dimension</title>
<p>We have reported that noncontact mapping performance deteriorates progressively as catheter dimensions are reduced relative to those of the cardiac chamber and that this degradation becomes more marked when activation is complex. Neither of these findings is surprising. With increasing distance from the heart surface, intracardiac potentials associated with local activation are progressively attenuated and blurred, and information lost in this process cannot be recovered fully. Furthermore, as catheter dimension is reduced, information is captured from a decreasing subset of the cavity volume which may not fully reflect local activity. More striking, perhaps, is the finding that surface electrograms can be reconstructed with acceptable accuracy (CC &#x3e; 0.9, nRMSE &#x2264;0.06 and &#x394;T &#x2264; 2&#xa0;ms) during reentrant rhythm with basket catheters that fill only half of the cavity. A supplementary point that needs to be made here, is that while relative catheter volume is an accessible measure of dimension, it scales with the third power of radius for a spherical basket catheter. Therefore, catheter volume increases by 112.5% when its diameter changes from 35 to 45&#xa0;mm. While there was no contact between electrodes and LA wall for the centrally located catheter in <xref ref-type="fig" rid="F3">Figure 3A</xref> (Catheter:Atrial volume ratio &#x3d; 0.67), there was increasing (though incomplete) contact between them as relative volume expanded to &#x223c;0.9.</p>
</sec>
<sec id="s5-3">
<title>Effects of Noise</title>
<p>Median CC was decreased and median &#x394;T was increased with reduced catheter dimension (<xref ref-type="fig" rid="F4">Figures 4B,D</xref>) when Gaussian noise was added but there was no corresponding effect on median nRMSE (<xref ref-type="fig" rid="F4">Figure 4C</xref>). The reconstructed electrograms in <xref ref-type="fig" rid="F4">Figure 4A</xref> provide explanation for these results. Because electrograms recorded toward the centre of the LA cavity with a small central catheter are attenuated, the noise added to them markedly reduces SNR. This is reflected in the reconstructed surface electrograms presented in the left-hand panel of <xref ref-type="fig" rid="F4">Figure 4A</xref>, where SNR is low and is reduced progressively as noise amplitude increases. The recorded electrograms are also smoothed in this case and the frequency content of the ground-truth surface electrograms is not recovered by inverse mapping. However, the overlap between ground-truth and reconstructed electrograms is affected less by noise than might have been expected. With increased noise power, the deviation between reconstructed and ground-truth electrograms can increase, but there is also greater instantaneous overlap between the two. With a large catheter (right-hand panel in <xref ref-type="fig" rid="F4">Figure 4A</xref>), the magnitudes of recorded electrograms are substantially greater and there is much less smoothing. As a result, surface electrograms are recovered more faithfully with much less impact of added noise.</p>
<p>Inverse methods are prone to instability and error in the presence of noise. The fact that this is not the case here further reinforces the fact that the transfer matrix used is inherently well-conditioned and the regularization procedures adopted are appropriate. However, the Gaussian noise introduced here is a very narrow representation of the problems faced in practice with inverse potential mapping. Artifacts in the unipolar signals used for this purpose include common-mode electrical noise, far-field activity due to electrical activation of the ventricles which can mask local activity completely in AF and complexity in atrial electrograms that may be due to far-field atrial activity, inadequate spatial sampling or non-uniform electrical properties in the underlying substrate. That said there are many ways that more robust regional information can be extracted from these channels using signal processing methods that exploit temporal and spatial correlation among adjacent electrograms and wavelet-based methods which identify characteristic differences in the instantaneous frequency content of recorded electrograms (<xref ref-type="bibr" rid="B31">Zhao et al., 2013</xref>).</p>
</sec>
<sec id="s5-4">
<title>Electrode Distribution and Recovery of Complex Activation Patterns</title>
<p>Our data show that ground truth potential maps based on simulated macro-reentrant activity were reconstructed more faithfully using a 130-electrode catheter than a 64-electrode catheter with the same dimension (<xref ref-type="fig" rid="F3">Figure 3</xref>). Furthermore, when noncontact electrodes were within a few mm of the cavity surface, dimension had no effect on the efficacy of the inverse solution, which was wholly dependent on electrode distribution. This reflects the fact that the accuracy with which surface potentials can be reconstructed depends on whether the sampled potentials provide a faithful representation of the field addressed. If the electrode distribution is not sufficiently dense, high spatial frequencies cannot be recovered and low frequency artifacts (aliasing) may occur (<xref ref-type="bibr" rid="B26">Shannon, 1949</xref>). An example of this is provided in <xref ref-type="fig" rid="F2">Figure 2</xref> where apparent fractionation of the electrogram reconstructed between adjacent splines with a 64 electrode basket catheter (see blue trace in <xref ref-type="fig" rid="F2">Figure 2F</xref>) disappears with more dense sampling in that region (compare red trace with ground truth electrogram in <xref ref-type="fig" rid="F2">Figure 2F</xref>). While compressed sensing approaches can collect and represent sparse signals with many fewer sampling points than indicated by the Nyquist (<xref ref-type="bibr" rid="B26">Shannon, 1949</xref>) theorem, optimal sampling strategies are determined by regional spatial and temporal correlation (<xref ref-type="bibr" rid="B13">Long et al., 2011</xref>). Specialized regularization techniques are also needed for inverse reconstruction of higher frequencies from sparsely sampled signals without introducing excessive noise.</p>
<p>It should be noted that metrics such as CC and nRMSE used here to quantify the correspondence between ground-truth and reconstructed potentials do not take the time-history of the electrograms into account. This provides additional information about the spread of electrical activation across the heart surface as illustrated by the phase maps in <xref ref-type="fig" rid="F5">Figure 5</xref>. The phase map shown here for a 64-electrode catheter is very similar to that presented for a 130-electrode catheter. Both correspond closely to ground truth phase maps throughout the activation sequence (<xref ref-type="sec" rid="s13">Supplementary Video S1</xref>). Because phase mapping identifies local activation as an abrupt standardized transition from &#x2b;&#x3c0; to &#x2212;&#x3c0; and imposes relatively uniform spatio-temporal variation around this, confounding effects of local variation in potential magnitude are removed.</p>
<p>It is also important to acknowledge that sampling density is affected by catheter dimensions. For instance, for a 64-electrode 25-mm diameter spherical catheter, inter-electrode spacing along splines is &#x223c;5&#xa0;mm, while the curvilinear distance between splines at the equator is &#x223c;10&#xa0;mm. These measurements are doubled with a 50-mm diameter catheter. This explains the apparent reduction in median CC and the increase in median nRMSE and its interquartile range for 64-electrode catheters when relative catheter volume increases from 0.8&#x2013;0.91 (<xref ref-type="fig" rid="F3">Figures 3D,E</xref>, respectively). Here any improvement in accuracy associated with proximity to the wall is offset by reduced electrode density. In the clinical setting, attempts to achieve direct contact between electrodes and the heart surface can introduce additional error by deforming catheter splines and increasing the nonuniformity of sampling. (<xref ref-type="bibr" rid="B18">Oesterlein et al., 2016</xref>; <xref ref-type="bibr" rid="B20">Pathik et al., 2018</xref>). It follows that global mapping with multi-electrode basket catheters is more likely to produce reliable results when electrodes are not in contact with the heart wall than when attempts are made to achieve close contact.</p>
<p>The results for RoI mapping are consistent with these observations. The relatively small 64-electrode catheter in <xref ref-type="fig" rid="F6">Figure 6</xref> recovered local electrical activity with a high level of accuracy. Moreover, regional mapping produced best results when electrodes were not in contact with the wall (median CC, nRMSE and &#x394;T: 0.96, 0.09 and 0.89&#xa0;ms, respectively). Global performance was much poorer, but it would be straightforward to quantify the uncertainty of reconstructed maps based on the distance of electrodes from surface nodes and the results of analyses such as those outlined here.</p>
</sec>
<sec id="s5-5">
<title>Potential Clinical Impact of These Findings</title>
<p>The results of this study indicate that global electroanatomic maps can be recovered faithfully in real-time from electrograms recorded with noncontact multi-electrode basket catheters using meshless methods that use the MFS. Accurate specification of 3D electrode locations with respect to cardiac anatomy is required for inverse intracardiac mapping, but this is readily achieved with current hybrid navigation technologies (<xref ref-type="bibr" rid="B11">Issa et al., 2019</xref>). Our findings indicate that, for optimal performance, catheters should be located centrally within the cardiac chamber and address a representative subvolume of the cavity (&#x3e;50% in the data presented here) with minimum contact between electrodes and endocardial surface. The capacity to reconstruct spatially complex activation patterns is limited by electrode distribution, but when heart rhythm is stable and repeated, more detailed maps can be reconstructed with sequential alteration of electrode locations, for instance by catheter rotation/translation. Potentially, this could be more efficient than sequential contact mapping with high density contact arrays because complete maps can be developed with relatively few iterations. For nonstationary heart rhythms such as AF, however, the accuracy with which endocardial surface activation can be reconstructed is constrained by the spatial distribution of electrodes on the catheter for both contact and noncontact mapping. Sparse sampling can lead to repeating artifact in reconstructed activation patterns that is incorrectly identified as rotors (<xref ref-type="bibr" rid="B24">Roney et al., 2017</xref>; <xref ref-type="bibr" rid="B14">Martinez- Mateu et al., 2018</xref>). Williams et al. (<xref ref-type="bibr" rid="B30">Williams et al., 2018</xref>) reported that &#x3e;1.0&#x2013;1.5 points/cm<sup>2</sup> were needed on the endocardial surface to resolve spiral wave activity and this corresponds to an inter-electrode spacing of 2&#x2013;3&#xa0;mm - much denser than is the case for 64-electrode basket catheters, particularly for equatorial electrodes on adjacent splines. As demonstrated here, more optimal electrode distribution is achieved with catheters that have 16 rather than 8 splines. While phase mapping may relax sampling requirements to some extent, it seems evident that improved catheter design is necessary for accurate panoramic mapping in AF.</p>
<p>Inverse methods have been used for noncontact intracardiac electrical mapping in two commercial systems. (<xref ref-type="bibr" rid="B25">Schilling et al., 1999</xref>; <xref ref-type="bibr" rid="B9">Grace et al., 2019</xref>). The Ensite multi-electrode array (Abbott) is used for noncontact potential mapping and consists of 64 electrodes mounted on an inflatable balloon. Consistent with the results reported here, validation studies have shown that accuracy is inversely related to the distance between the array and the heart wall with poor recovery of endocardial surface potentials when this distance is &#x3e;25&#xa0;mm (<xref ref-type="bibr" rid="B6">Earley et al., 2006</xref>). More recently, instantaneous charge density distributions associated with atrial electrical activation have been constructed from electrograms recorded with noncontact 48-electrode basket catheters (Acutus/Biotronik) (<xref ref-type="bibr" rid="B9">Grace et al., 2019</xref>). This is based on a forward model that relates intracardiac potential fields to secondary cellular sources associated with distributed membrane charge dipoles (<xref ref-type="bibr" rid="B21">Plonsey, 1982</xref>; <xref ref-type="bibr" rid="B9">Grace et al., 2019</xref>; <xref ref-type="bibr" rid="B29">Willems et al., 2019</xref>). Our analysis makes no assumptions about the cellular basis of electrical activation. Instead, we address how well endocardial surface potentials can be recovered from a limited number of electrograms recorded inside the heart cavity. We found that information is lost with noncontact mapping if the basket catheters used are too small and with both contact and noncontact mapping if the sampling density is not sufficient. These factors would be expected to impact the spatial resolution with which surface charge distributions can be recovered from noncontact electrograms also.</p>
</sec>
<sec id="s5-6">
<title>Limitations</title>
<p>A limitation of this study is that error introduced by uncertainty of the 3D geometry of the heart surface relative to 3D electrode locations has not been explicitly considered. While this would be expected to amplify uncertainty associated with relative catheter size, electrode distribution and noise, we note that our formulation of the intracardiac inverse problem is surprisingly robust. A further limitation is that although our ground-truth data represent atrial rhythms of increasing complexity, they do not fully replicate the spatio-temporal disorder which characterizes AF. However, the analysis presented here demonstrates that the performance of contact mapping is matched by this inverse approach and that spatial resolution in both cases is limited by electrode distribution. Finally, while ground-truth data are based in part on clinical and simulated data, the accuracy of inverse intracardiac mapping has been confirmed computationally. While many of the assumptions made in specifying the forward problem are entirely reasonable, other are not. The electrical properties of the blood in the cardiac chambers are isotropic and uniform but they are certainly not the same as those in the myocardium adjacent to the endocardial surface where the fictitious sources are located. More detailed experimental characterization of the accuracy with which endocardial potentials can be reconstructed using inverse mapping is therefore needed to confirm the analyses presented here.</p>
</sec>
</sec>
<sec sec-type="conclusion" id="s6">
<title>Conclusion</title>
<p>This study demonstrates that atrial endocardial potentials can be reconstructed accurately from electrograms recorded with noncontact multi-electrode basket catheters using a fast robust inverse mapping approach that employs the MFS. This enables efficient and potentially more precise capture of global and region-of-interest potential maps than comparable contact mapping methods. Because data for all electrodes are used, it is not necessary to maximize contact between catheter and the heart wall. This reduces the deformation of catheter splines which occurs when direct contact is sought, thereby preserving a more uniform electrode distribution. However, we demonstrate that conventional 8 spline catheters are suboptimal for instantaneous contact or noncontact mapping of complex rhythms, such as AF.</p>
</sec>
</body>
<back>
<sec id="s7">
<title>Data Availability Statement</title>
<p>The raw data supporting the conclusion of this article will be made available by the authors, without undue reservation.</p>
</sec>
<sec id="s8">
<title>Ethics Statement</title>
<p>The studies involving human participants were reviewed and approved by the Melbourne Health Rseearch and Human Ethics Committee. The patients/participants provided their written informed consent to participate in this study. The animal study was reviewed and approved by the Animal Ethics Committee of the University of Auckland.</p>
</sec>
<sec id="s9">
<title>Author Contributions</title>
<p>SM and NS jointly completed all aspects of the <italic>in silico</italic> analysis presented here and developed the computational pipeline used. JC-S is responsible for our use of the Method of Fundamental Solutions (MFS), completed 2D prototype studies using this approach and was influential in the direction taken in this work. LB wrote our initial 3D MFS code. SM, BS, IL, NL, AG, GS, and JZ designed, performed and analyzed animal experiments which provided data for this study. JZ contributed to the simulation of reentrant arrhythmia and provided phase mapping code. SM, NS, and BS generated the figures. SM, NS, GS, and BS wrote the manuscript. BS and DB were responsible for funding and direction of the project. All authors contributed to manuscript revision, read, and approved the version submitted.</p>
</sec>
<sec id="s10">
<title>Funding</title>
<p>This study received financial support from the Health Research Council of New Zealand Programme Grant 13/77 and New Zealand Ministry of Business and Innovation Project Grant UOAX1717.</p>
</sec>
<sec sec-type="COI-statement" id="s11">
<title>Conflict of Interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
<p>The reviewer EJV declared a shared affiliation with one of the authors LRB at the time of review.</p>
</sec>
<sec sec-type="disclaimer" id="s12">
<title>Publisher&#x2019;s Note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ack>
<p>We gratefully acknowledge the input of JM Kalman, Royal Melbourne Hospital, Parkville, Australia and University of Melbourne, Parkville, Australia who provided high resolution mapping data from one patient (identity protected). We also thank Linley Nisbet for her expert assistance with animal studies carried out in Auckland.</p>
</ack>
<sec id="s13">
<title>Supplementary Material</title>
<p>The Supplementary Material for this article can be found online at: <ext-link ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/fphys.2022.873049/full#supplementary-material">https://www.frontiersin.org/articles/10.3389/fphys.2022.873049/full&#x23;supplementary-material</ext-link>
</p>
<supplementary-material xlink:href="Image1.PNG" id="SM1" mimetype="application/PNG" xmlns:xlink="http://www.w3.org/1999/xlink"/>
<supplementary-material xlink:href="Video1.MP4" id="SM2" mimetype="application/MP4" xmlns:xlink="http://www.w3.org/1999/xlink"/>
</sec>
<ref-list>
<title>References</title>
<ref id="B2">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bear</surname>
<given-names>L. R.</given-names>
</name>
<name>
<surname>LeGrice</surname>
<given-names>I. J.</given-names>
</name>
<name>
<surname>Sands</surname>
<given-names>G. B.</given-names>
</name>
<name>
<surname>Lever</surname>
<given-names>N. A.</given-names>
</name>
<name>
<surname>Loiselle</surname>
<given-names>D. S.</given-names>
</name>
<name>
<surname>Paterson</surname>
<given-names>D. J.</given-names>
</name>
<etal/>
</person-group> (<year>2018</year>). <article-title>How Accurate Is Inverse Electrocardiographic Mapping? A Systematic <italic>In Vivo</italic> Evaluation</article-title>. <source>Circ. Arrhythm. Electrophysiol.</source> <volume>11</volume>, <fpage>e006108</fpage>. <pub-id pub-id-type="doi">10.1161/CIRCEP.117.006108</pub-id> </citation>
</ref>
<ref id="B3">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Botsch</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Kobbelt</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Pauly</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Alliez</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>L&#xe9;vy</surname>
<given-names>B.</given-names>
</name>
</person-group> (<year>2010</year>). in <source>Polygon Mesh Processing</source>. Editor <person-group person-group-type="editor">
<name>
<surname>Peters</surname>
<given-names>A. K.</given-names>
</name>
</person-group> (<publisher-loc>Boca Raton, FL</publisher-loc>: <publisher-name>CRC Press</publisher-name>). </citation>
</ref>
<ref id="B4">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Burton</surname>
<given-names>B. M.</given-names>
</name>
<name>
<surname>Tate</surname>
<given-names>J. D.</given-names>
</name>
<name>
<surname>Erem</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Swenson</surname>
<given-names>D. J.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>D. F.</given-names>
</name>
<name>
<surname>Steffen</surname>
<given-names>M.</given-names>
</name>
<etal/>
</person-group> (<year>2011</year>). <article-title>A Toolkit for Forward/inverse Problems in Electrocardiography within the SCIRun Problem Solving Environment</article-title>. <source>Annu. Int. Conf. IEEE Eng. Med. Biol. Soc.</source> <volume>2011</volume>, <fpage>267</fpage>&#x2013;<lpage>270</lpage>. <pub-id pub-id-type="doi">10.1109/IEMBS.2011.6090052</pub-id> </citation>
</ref>
<ref id="B5">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cluitmans</surname>
<given-names>M. J. M.</given-names>
</name>
<name>
<surname>Bonizzi</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Karel</surname>
<given-names>J. M. H.</given-names>
</name>
<name>
<surname>Das</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Kietselaer</surname>
<given-names>B. L. J. H.</given-names>
</name>
<name>
<surname>de Jong</surname>
<given-names>M. M. J.</given-names>
</name>
<etal/>
</person-group> (<year>2017</year>). <article-title>
<italic>In Vivo</italic> Validation of Electrocardiographic Imaging</article-title>. <source>JACC Clin. Electrophysiol.</source> <volume>3</volume>, <fpage>232</fpage>&#x2013;<lpage>242</lpage>. <pub-id pub-id-type="doi">10.1016/j.jacep.2016.11.012</pub-id> </citation>
</ref>
<ref id="B6">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Earley</surname>
<given-names>M. J.</given-names>
</name>
<name>
<surname>Abrams</surname>
<given-names>D. J. R.</given-names>
</name>
<name>
<surname>Sporton</surname>
<given-names>S. C.</given-names>
</name>
<name>
<surname>Schilling</surname>
<given-names>R. J.</given-names>
</name>
</person-group> (<year>2006</year>). <article-title>Validation of the Noncontact Mapping System in the Left Atrium during Permanent Atrial Fibrillation and Sinus Rhythm</article-title>. <source>J. Am. Coll. Cardiol.</source> <volume>48</volume>, <fpage>485</fpage>&#x2013;<lpage>491</lpage>. <pub-id pub-id-type="doi">10.1016/j.jacc.2006.04.069</pub-id> </citation>
</ref>
<ref id="B7">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Fairweather</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Karageorghis</surname>
<given-names>A.</given-names>
</name>
</person-group> (<year>1998</year>). <article-title>The Method of Fundamental Solutions for Elliptic Boundary Value Problems</article-title>. <source>Adv. Comput. Math.</source> <volume>9</volume>, <fpage>69</fpage>&#x2013;<lpage>95</lpage>. </citation>
</ref>
<ref id="B8">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Fenton</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Karma</surname>
<given-names>A.</given-names>
</name>
</person-group> (<year>1998</year>). <article-title>Vortex Dynamics in Three-Dimensional Continuous Myocardium with Fiber Rotation: Filament Instability and Fibrillation</article-title>. <source>Chaos</source> <volume>8</volume>, <fpage>20</fpage>&#x2013;<lpage>47</lpage>. <pub-id pub-id-type="doi">10.1063/1.166311</pub-id> </citation>
</ref>
<ref id="B9">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Grace</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Willems</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Meyer</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Verma</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Heck</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Zhu</surname>
<given-names>M.</given-names>
</name>
<etal/>
</person-group> (<year>2019</year>). <article-title>High-resolution Noncontact Charge-Density Mapping of Endocardial Activation</article-title>. <source>JCI Insight</source> <volume>4</volume>, <fpage>e126422</fpage>. <pub-id pub-id-type="doi">10.1172/jci.insight.126422</pub-id> </citation>
</ref>
<ref id="B10">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Hansen</surname>
<given-names>P.</given-names>
</name>
</person-group> (<year>2010</year>). <source>Discrete Inverse Problems</source>. <publisher-loc>Philadelphia</publisher-loc>: <publisher-name>SIAM</publisher-name>. </citation>
</ref>
<ref id="B11">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Issa</surname>
<given-names>Z. F.</given-names>
</name>
<name>
<surname>Miller</surname>
<given-names>J. M.</given-names>
</name>
<name>
<surname>Zipes</surname>
<given-names>D. P.</given-names>
</name>
</person-group> (<year>2019</year>). &#x201c;<article-title>Advanced Mapping and Navigation Modalities</article-title>,&#x201d; in <source>Clinical Arrhythmology and Electrophysiology: A Companion to Braunwald&#x2019;s Heart Disease</source>. <edition>3rd Edition</edition>. (<publisher-name>Elsevier</publisher-name>), <fpage>155</fpage>&#x2013;<lpage>205</lpage>. <comment>Chapter 6 In</comment>. <pub-id pub-id-type="doi">10.1016/b978-0-323-52356-1.00006-2</pub-id> </citation>
</ref>
<ref id="B12">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kuklik</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Zeemering</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>van Hunnik</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Maesen</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Pison</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Lau</surname>
<given-names>D. H.</given-names>
</name>
<etal/>
</person-group> (<year>2017</year>). <article-title>Identification of Rotors during Human Atrial Fibrillation Using Contact Mapping and Phase Singularity Detection: Technical Considerations</article-title>. <source>IEEE Trans. Biomed. Eng.</source> <volume>64</volume>, <fpage>310</fpage>&#x2013;<lpage>318</lpage>. <pub-id pub-id-type="doi">10.1109/TBME.2016.2554660</pub-id> </citation>
</ref>
<ref id="B13">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Long</surname>
<given-names>C. J.</given-names>
</name>
<name>
<surname>Purdon</surname>
<given-names>P. L.</given-names>
</name>
<name>
<surname>Temereanca</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Desai</surname>
<given-names>N. U.</given-names>
</name>
<name>
<surname>H&#xe4;m&#xe4;l&#xe4;inen</surname>
<given-names>M. S.</given-names>
</name>
<name>
<surname>Brown</surname>
<given-names>E. N.</given-names>
</name>
</person-group> (<year>2011</year>). <article-title>State-space Solutions to the Dynamic Magnetoencephalography Inverse Problem Using High Performance Computing</article-title>. <source>Ann. Appl. Stat.</source> <volume>5</volume>, <fpage>1207</fpage>&#x2013;<lpage>1228</lpage>. <pub-id pub-id-type="doi">10.1214/11-AOAS483</pub-id> </citation>
</ref>
<ref id="B14">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Martinez-Mateu</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Romero</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Ferrer-Albero</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Sebastian</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Rodr&#xed;guez Matas</surname>
<given-names>J. F.</given-names>
</name>
<name>
<surname>Jalife</surname>
<given-names>J.</given-names>
</name>
<etal/>
</person-group> (<year>2018</year>). <article-title>Factors Affecting Basket Catheter Detection of Real and Phantom Rotors in the Atria: A Computational Study</article-title>. <source>PLoS Comput. Biol.</source> <volume>14</volume>, <fpage>e1006017</fpage>. <pub-id pub-id-type="doi">10.1371/journal.pcbi.1006017</pub-id> </citation>
</ref>
<ref id="B15">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Meng</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Zhao</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>LeGrice</surname>
<given-names>I.</given-names>
</name>
<name>
<surname>Lever</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Sands</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Bear</surname>
<given-names>L.</given-names>
</name>
<etal/>
</person-group> (<year>2017</year>). <article-title>Atrial Electro-Anatomic Mapping with a Novel Noncontact Approach</article-title>. <source>Comput. Cardiol.</source> <volume>44</volume>, <fpage>1</fpage>&#x2013;<lpage>4</lpage>. <pub-id pub-id-type="doi">10.22489/cinc.2017.105-291</pub-id> </citation>
</ref>
<ref id="B16">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Meng</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Chamorro-Servent</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Sunderland</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Zhao</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Bear</surname>
<given-names>L. R.</given-names>
</name>
<name>
<surname>Sands</surname>
<given-names>G. B.</given-names>
</name>
<etal/>
</person-group> (<year>2022</year>). <source>Noncontact Intracardiac Potential Mapping: A Comparison of Boundary Mesh-based and Meshless Inverse Solvers</source>. <source>Front. Physiol.</source>. <comment>(In Review)</comment>. </citation>
</ref>
<ref id="B17">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Narayan</surname>
<given-names>S. M.</given-names>
</name>
<name>
<surname>Krummen</surname>
<given-names>D. E.</given-names>
</name>
<name>
<surname>Rappel</surname>
<given-names>W.-J.</given-names>
</name>
</person-group> (<year>2012</year>). <article-title>Clinical Mapping Approach to Diagnose Electrical Rotors and Focal Impulse Sources for Human Atrial Fibrillation</article-title>. <source>J. Cardiovasc. Electrophysiol.</source> <volume>23</volume> (<issue>5</issue>), <fpage>447</fpage>&#x2013;<lpage>454</lpage>. <pub-id pub-id-type="doi">10.1111/j.1540-8167.2012.02332.x</pub-id> </citation>
</ref>
<ref id="B18">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Oesterlein</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Frisch</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Loewe</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Seemann</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Schmitt</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>D&#xf6;ssel</surname>
<given-names>O.</given-names>
</name>
<etal/>
</person-group> (<year>2016</year>). <article-title>Basket-type Catheters: Diagnostic Pitfalls Caused by Deformation and Limited Coverage</article-title>. <source>Biomed. Res. Int.</source> <volume>2016</volume>, <fpage>5340574</fpage>. <pub-id pub-id-type="doi">10.1155/2016/5340574</pub-id> </citation>
</ref>
<ref id="B19">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pandit</surname>
<given-names>S. V.</given-names>
</name>
<name>
<surname>Berenfeld</surname>
<given-names>O.</given-names>
</name>
<name>
<surname>Anumonwo</surname>
<given-names>J. M. B.</given-names>
</name>
<name>
<surname>Zaritski</surname>
<given-names>R. M.</given-names>
</name>
<name>
<surname>Kneller</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Nattel</surname>
<given-names>S.</given-names>
</name>
<etal/>
</person-group> (<year>2005</year>). <article-title>Ionic Determinants of Functional Reentry in a 2-D Model of Human Atrial Cells during Simulated Chronic Atrial Fibrillation</article-title>. <source>Biophys. J.</source> <volume>88</volume>, <fpage>3806</fpage>&#x2013;<lpage>3821</lpage>. <pub-id pub-id-type="doi">10.1529/biophysj.105.060459</pub-id> </citation>
</ref>
<ref id="B20">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pathik</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Kalman</surname>
<given-names>J. M.</given-names>
</name>
<name>
<surname>Walters</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Kuklik</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Zhao</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Madry</surname>
<given-names>A.</given-names>
</name>
<etal/>
</person-group> (<year>2018</year>). <article-title>Transient Rotor Activity during Prolonged 3-dimensional Phase Mapping in Human Persistent Atrial Fibrillation</article-title>. <source>JACC Clin. Electrophysiol.</source> <volume>4</volume>, <fpage>72</fpage>&#x2013;<lpage>83</lpage>. <pub-id pub-id-type="doi">10.1016/j.jacep.2017.06.005</pub-id> </citation>
</ref>
<ref id="B21">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Plonsey</surname>
<given-names>R.</given-names>
</name>
</person-group> (<year>1982</year>). <article-title>The Nature of Sources of Bioelectric and Biomagnetic Fields</article-title>. <source>Biophysical J.</source> <volume>39</volume>, <fpage>309</fpage>&#x2013;<lpage>312</lpage>. <pub-id pub-id-type="doi">10.1016/s0006-3495(82)84521-9</pub-id> </citation>
</ref>
<ref id="B22">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Pullan</surname>
<given-names>A. J.</given-names>
</name>
<name>
<surname>Buist</surname>
<given-names>M. L.</given-names>
</name>
<name>
<surname>Cheng</surname>
<given-names>L. K.</given-names>
</name>
</person-group> (<year>2005</year>). <source>Mathematically Modelling the Electrical Activity of the Heart: From Cell to Body Surface and Back Again</source>. <publisher-loc>Singapore</publisher-loc>: <publisher-name>World Scientific Publishing</publisher-name>. </citation>
</ref>
<ref id="B23">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ramanathan</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Rudy</surname>
<given-names>Y.</given-names>
</name>
</person-group> (<year>2001</year>). <article-title>Electrocardiographic Imaging: I. Effect of Torso Inhomogeneities on Body Surface Electrocardiographic Potentials</article-title>. <source>J. Cardiovasc Electrophysiol.</source> <volume>12</volume>, <fpage>229</fpage>&#x2013;<lpage>240</lpage>. <pub-id pub-id-type="doi">10.1046/j.1540-8167.2001.00229.x</pub-id> </citation>
</ref>
<ref id="B24">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Roney</surname>
<given-names>C. H.</given-names>
</name>
<name>
<surname>Cantwell</surname>
<given-names>C. D.</given-names>
</name>
<name>
<surname>Bayer</surname>
<given-names>J. D.</given-names>
</name>
<name>
<surname>Qureshi</surname>
<given-names>N. A.</given-names>
</name>
<name>
<surname>Lim</surname>
<given-names>P. B.</given-names>
</name>
<name>
<surname>Tweedy</surname>
<given-names>J. H.</given-names>
</name>
<etal/>
</person-group> (<year>2017</year>). <article-title>Spatial Resolution Requirements for Accurate Identification of Drivers of Atrial Fibrillation</article-title>. <source>Circ. Arrhythm. Electrophysiol.</source> <volume>10</volume>, <fpage>e004899</fpage>. <pub-id pub-id-type="doi">10.1161/CIRCEP.116.004899</pub-id> </citation>
</ref>
<ref id="B25">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Schilling</surname>
<given-names>R. J.</given-names>
</name>
<name>
<surname>Peters</surname>
<given-names>N. S.</given-names>
</name>
<name>
<surname>Davies</surname>
<given-names>D. W.</given-names>
</name>
</person-group> (<year>1999</year>). <article-title>Feasibility of a Noncontact Catheter for Endocardial Mapping of Human Ventricular Tachycardia</article-title>. <source>Circulation</source> <volume>99</volume>, <fpage>2543</fpage>&#x2013;<lpage>2552</lpage>. <pub-id pub-id-type="doi">10.1161/01.cir.99.19.2543</pub-id> </citation>
</ref>
<ref id="B26">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Shannon</surname>
<given-names>C. E.</given-names>
</name>
</person-group> (<year>1949</year>). <article-title>Communication in the Presence of Noise</article-title>. <source>Proc. IRE</source> <volume>37</volume>, <fpage>10</fpage>&#x2013;<lpage>21</lpage>. <pub-id pub-id-type="doi">10.1109/jrproc.1949.232969</pub-id> </citation>
</ref>
<ref id="B27">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Tikhonov</surname>
<given-names>A. N.</given-names>
</name>
<name>
<surname>Arsenin</surname>
<given-names>V. Y.</given-names>
</name>
</person-group> (<year>1977</year>). <source>Solutions of Ill-Posed Problems</source>. <publisher-loc>Washington DC</publisher-loc>: <publisher-name>Winston and Sons</publisher-name>. </citation>
</ref>
<ref id="B28">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Rudy</surname>
<given-names>Y.</given-names>
</name>
</person-group> (<year>2006</year>). <article-title>Application of the Method of Fundamental Solutions to Potential-Based Inverse Electrocardiography</article-title>. <source>Ann. Biomed. Eng.</source> <volume>34</volume>, <fpage>1272</fpage>&#x2013;<lpage>1288</lpage>. <pub-id pub-id-type="doi">10.1007/s10439-006-9131-7</pub-id> </citation>
</ref>
<ref id="B29">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Willems</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Verma</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Betts</surname>
<given-names>T. R.</given-names>
</name>
<name>
<surname>Murray</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Neuzil</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Ince</surname>
<given-names>H.</given-names>
</name>
<etal/>
</person-group> (<year>2019</year>). <article-title>Targeting Nonpulmonary Vein Sources in Persistent Atrial Fibrillation Identified by Noncontact Charge Density Mapping: UNCOVER AF Trial</article-title>. <source>Circ. Arrhythm. Electrophysiol.</source> <volume>12</volume>, <fpage>e007233</fpage>. <pub-id pub-id-type="doi">10.1161/CIRCEP.119.007233</pub-id> </citation>
</ref>
<ref id="B30">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Williams</surname>
<given-names>S. E.</given-names>
</name>
<name>
<surname>Harrison</surname>
<given-names>J. L.</given-names>
</name>
<name>
<surname>Chubb</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Whitaker</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Kiedrowicz</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Rinaldi</surname>
<given-names>C. A.</given-names>
</name>
<etal/>
</person-group> (<year>2018</year>). <article-title>Local Activation Time Sampling Density for Atrial Tachycardia Contact Mapping: How Much Is Enough?</article-title> <source>Europace</source> <volume>20</volume>, <fpage>e11</fpage>&#x2013;<lpage>e20</lpage>. <pub-id pub-id-type="doi">10.1093/europace/eux037</pub-id> </citation>
</ref>
<ref id="B31">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhao</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Yao</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Huang</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Shi</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>LeGrice</surname>
<given-names>I. J.</given-names>
</name>
<etal/>
</person-group> (<year>2013</year>). <article-title>Novel Methods for Characterization of Paroxysmal Atrial Fibrillation in Human Left Atria</article-title>. <source>Tobej</source> <volume>7</volume>, <fpage>29</fpage>&#x2013;<lpage>40</lpage>. <pub-id pub-id-type="doi">10.2174/1874120701307010029</pub-id> </citation>
</ref>
</ref-list>
</back>
</article>