<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="review-article">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Physiol.</journal-id>
<journal-title>Frontiers in Physiology</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Physiol.</abbrev-journal-title>
<issn pub-type="epub">1664-042X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fphys.2017.00983</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Physiology</subject>
<subj-group>
<subject>Mini Review</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Monitoring Energy Expenditure Using a Multi-Sensor Device&#x02014;Applications and Limitations of the SenseWear Armband in Athletic Populations</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes">
<name><surname>Koehler</surname> <given-names>Karsten</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="author-notes" rid="fn001"><sup>&#x0002A;</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/408723/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Drenowatz</surname> <given-names>Clemens</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/149181/overview"/>
</contrib>
</contrib-group>
<aff id="aff1"><sup>1</sup><institution>Department of Nutrition and Health Sciences, University of Nebraska-Lincoln</institution>, <addr-line>Lincoln, NE</addr-line>, <country>United States</country></aff>
<aff id="aff2"><sup>2</sup><institution>Division of Physical Education, University of Education Upper Austria</institution>, <addr-line>Linz</addr-line>, <country>Austria</country></aff>
<author-notes>
<fn fn-type="edited-by"><p>Edited by: Billy Sperlich, Universit&#x000E4;t W&#x000FC;rzburg, Germany</p></fn>
<fn fn-type="edited-by"><p>Reviewed by: Salvatore Tedesco, University College Cork, Ireland; Beat Knechtle, University of Zurich, Switzerland</p></fn>
<fn fn-type="corresp" id="fn001"><p>&#x0002A;Correspondence: Karsten Koehler <email>kkoehler3&#x00040;unl.edu</email></p></fn>
<fn fn-type="other" id="fn002"><p>This article was submitted to Exercise Physiology, a section of the journal Frontiers in Physiology</p></fn></author-notes>
<pub-date pub-type="epub">
<day>30</day>
<month>11</month>
<year>2017</year>
</pub-date>
<pub-date pub-type="collection">
<year>2017</year>
</pub-date>
<volume>8</volume>
<elocation-id>983</elocation-id>
<history>
<date date-type="received">
<day>27</day>
<month>09</month>
<year>2017</year>
</date>
<date date-type="accepted">
<day>17</day>
<month>11</month>
<year>2017</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x000A9; 2017 Koehler and Drenowatz.</copyright-statement>
<copyright-year>2017</copyright-year>
<copyright-holder>Koehler and Drenowatz</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license>
</permissions>
<abstract><p>In order to monitor their energy requirements, athletes may desire to assess energy expenditure (EE) during training and competition. Recent technological advances and increased customer interest have created a market for wearable devices that measure physiological variables and bodily movement over prolonged time periods and convert this information into EE data. This mini-review provides an overview of the applicability of the SenseWear armband (SWA), which combines accelerometry with measurements of heat production and skin conductivity, to measure total daily energy expenditure (TDEE) and its components such as exercise energy expenditure (ExEE) in athletic populations. While the SWA has been shown to provide valid estimates of EE in the general population, validation studies in athletic populations indicate a tendency toward underestimation of ExEE particularly during high-intensity exercise (&#x0003E;10 METs) with an increasing underestimation as exercise intensity increases. Although limited information is available on the accuracy of the SWA during resistance exercise, high-intensity interval exercise, or mixed exercise forms, there seems to be a similar trend of underestimating high levels of ExEE. The SWA, however, is capable of detecting movement patterns and metabolic measurements even at high exercise intensities, suggesting that underestimation may result from limitations in the proprietary algorithms. In addition, the SWA has been used in the assessment of sleep quantity and quality as well as non-exercise activity thermogenesis. Overall, the SWA provides viable information and remains to be used in various clinical and athletic settings, despite the termination of its commercial sale.</p></abstract>
<kwd-group>
<kwd>accelerometry</kwd>
<kwd>energy balance</kwd>
<kwd>high-intensity exercise</kwd>
<kwd>resistance exercise</kwd>
<kwd>measurement error</kwd>
</kwd-group>
<counts>
<fig-count count="2"/>
<table-count count="0"/>
<equation-count count="0"/>
<ref-count count="55"/>
<page-count count="7"/>
<word-count count="5647"/>
</counts>
</article-meta>
</front>
<body>
<sec id="s1">
<title>Introduction: tracking energy expenditure in athletes</title>
<p>One of the unique characteristics of athletes is that energy requirements of training and competition increase their total daily energy expenditure (TDEE) beyond those of the general population (Westerterp, <xref ref-type="bibr" rid="B52">2013</xref>). Energy requirements can vary considerably depending on exercise type, intensity, and duration, but sustained levels of energy expenditure (EE) can be in the range of 5,000&#x02013;8,000 kcal/day (Westerterp et al., <xref ref-type="bibr" rid="B53">1986</xref>; Westerterp, <xref ref-type="bibr" rid="B51">2001</xref>). This high energy turnover has implications not only for weight gain and weight loss practices, which are prominent in sports with weight classes, anti-gravitational sports, or aesthetic sports; it also necessitates a sufficient dietary energy intake, as sustained energy deficiency can result in long-term detriments including impaired bone health and infertility (Loucks et al., <xref ref-type="bibr" rid="B30">2011</xref>). In addition, recent data suggest that athletic performance may also be impaired in energy-deprived athletes (Vanheest et al., <xref ref-type="bibr" rid="B44">2013</xref>).</p>
<p>Because of the high energy demands and the consequences of energy deficiency, tracking EE is paramount for many athletes and their support staff. Considering that athletes expend up to 75% of their TDEE during exercise (Westerterp, <xref ref-type="bibr" rid="B52">2013</xref>), quantifying energy needs during training and competition requires particular attention. The current gold-standard method for the assessment of TDEE in free-living situations is the doubly labeled water (DLW) method, which has been used in numerous athletic settings (Westerterp et al., <xref ref-type="bibr" rid="B53">1986</xref>; Sj&#x000F6;din et al., <xref ref-type="bibr" rid="B40">1994</xref>; Trappe et al., <xref ref-type="bibr" rid="B43">1997</xref>; Hill and Davies, <xref ref-type="bibr" rid="B20">2001</xref>, <xref ref-type="bibr" rid="B21">2002</xref>; Ebine et al., <xref ref-type="bibr" rid="B15">2002</xref>; Ekelund et al., <xref ref-type="bibr" rid="B16">2002</xref>; Koehler et al., <xref ref-type="bibr" rid="B26">2010</xref>). However, the time resolution is limited and the method does not differentiate between various components contributing to TDEE, such as exercise energy expenditure (ExEE) (Westerterp et al., <xref ref-type="bibr" rid="B53">1986</xref>). Improved resolution is provided by indirect calorimetry (IC), the reference method for EE quantification in controlled laboratory settings (Haugen et al., <xref ref-type="bibr" rid="B19">2007</xref>). However, despite recent methodological advances, the method remains mostly limited to research and exercise testing. Further, the requirement of a face mask hinders natural training behaviors such as fluid or food intake. Therefore, other approaches that do not interfere with training and competition practices are needed to reliably quantify EE, and particularly ExEE, in athletes.</p>
<p>Available methods include accelerometry, pedometry, heart-rate monitors, and self-report methods (Ndahimana and Kim, <xref ref-type="bibr" rid="B35">2017</xref>). With the exception of self-report methods, which only provide subjective information and show low accuracy and reliability (Ndahimana and Kim, <xref ref-type="bibr" rid="B35">2017</xref>), all of these approaches have been incorporated in activity monitors. These devices are less cost-prohibitive than DLW or IC, can be used during a wide range of activities and numerous settings, and allow for data collection over prolonged time intervals in large cohorts (D&#x000FC;king et al., <xref ref-type="bibr" rid="B12">2016</xref>). Several such wearable devices, including the ActiGraph, Actical, RT3, ActivePAL, or GeneActiv, have been developed for research purposes, and various companies have introduced commercial physical activity trackers (e.g., Fitbit, Garmin, Jawbone, Nike). However, as these devices typically rely only on accelerometry, they provide mixed accuracy with regard to its ability to predict EE or time spent in different activities (Welk et al., <xref ref-type="bibr" rid="B49">2007</xref>) and the ability to detect when devices are worn may be limited (Jaeschke et al., <xref ref-type="bibr" rid="B22">2017</xref>).</p>
</sec>
<sec id="s2">
<title>Technology of the SenseWear armband: features, functions, and modifications</title>
<p>The SenseWear armband (SWA) developed by BodyMedia Inc. (Pittsburgh, PA, USA) combines accelerometry with additional biological variables, such as heat flux, skin temperature, near-body ambient temperature, and galvanic skin response. The device only collects data when it is in direct contact with the skin and its pattern-recognition algorithm has been shown to provide more accurate results for estimating EE and time spent in various activities when compared to the ActiGraph (Welk et al., <xref ref-type="bibr" rid="B49">2007</xref>). Given these benefits, the SWA became a promising tool to objectively monitor EE in various exercise and non-exercise settings (Fruin and Rankin, <xref ref-type="bibr" rid="B17">2004</xref>). Most basic principles and functions have remained the same since the initial introduction of the first prototypes in the late 1990s, but there have been several upgrades, the most notable modification being the addition of a third dimension accelerometer axis (Riou et al., <xref ref-type="bibr" rid="B39">2015</xref>) along with increased data transfer and storage capacity. Per manufacturer instructions, the SWA is worn on the upper left arm, and can be used to record data continuously for up to 3&#x02013;4 weeks (Koehler et al., <xref ref-type="bibr" rid="B28">2013</xref>). Data can be downloaded, viewed, and exported for subsequent data processing using manufacturer software (InnerView, BodyMedia, Pittsburgh, PA). A proprietary algorithm converts raw data into estimates of EE, which are expressed both in kcal/min and metabolic equivalents (METs). In efforts to improve the validity of the SWA, this algorithm has been modified several times (Jakicic et al., <xref ref-type="bibr" rid="B23">2004</xref>; Van Hoye et al., <xref ref-type="bibr" rid="B45">2015</xref>). Although the technology was purchased by a competitor in 2013 and has since been discontinued (Welk et al., <xref ref-type="bibr" rid="B50">2017</xref>), the SWA continues to be used extensively in research and clinical settings (Figure <xref ref-type="fig" rid="F1">1</xref>). Considering the continued popularity and the current lack of alternatives on the market, it was our goal to provide a critical review of the applicability of the SWA to measure EE specifically in athletes. As such, we provide a general overview of the strength and limitations of the SWA in the general population (section Validity of the SenseWear Armband in the General Population: Energy Expenditure, Physical Activity, and Exercise), followed by a review of the validity of the SWA in athletes and during various types of high-intensity exercise (section Validity of the SenseWear Armband during High-Intensity Exercise). We further discuss possible reasons for limitations (section Limitations of the SenseWear Armband: Algorithm vs. Methodology) and non-traditional applications of the SWA in athletic settings (section Application of the SenseWear Armband in Athletic Populations). To identify appropriate literature, a quasi-systematic PUBMED search (<ext-link ext-link-type="uri" xlink:href="https://www.ncbi.nlm.nih.gov/pubmed/">https://www.ncbi.nlm.nih.gov/pubmed/</ext-link>) was conducted in June 2017 independently by both authors, using &#x0201C;SenseWear&#x0201D; in combination with &#x0201C;exercise,&#x0201D; &#x0201C;activity,&#x0201D; or &#x0201C;athletes&#x0201D; as search terms. In addition, we included literature cited. Final inclusion was decided on by a joint decision from both authors based on each paper&#x00027;s relevance to the review&#x00027;s target group.</p>
<fig id="F1" position="float">
<label>Figure 1</label>
<caption><p>Distribution of publications including the search term &#x0201C;SenseWear&#x0201D; for the period from 2004 (first publication) to 2016 (last complete year); data source: <ext-link ext-link-type="uri" xlink:href="https://www.ncbi.nlm.nih.gov/pubmed/">https://www.ncbi.nlm.nih.gov/pubmed/</ext-link> (Aug 14, 2017).</p></caption>
<graphic xlink:href="fphys-08-00983-g0001.tif"/>
</fig>
</sec>
<sec id="s3">
<title>Validity of the SenseWear armband in the general population: energy expenditure, physical activity, and exercise</title>
<p>In the general population, the SWA has been validated extensively and has been shown to provide accurate estimates of TDEE as well as EE at rest and during activities of light to moderate intensities when compared to DLW or IC (Cole et al., <xref ref-type="bibr" rid="B7">2004</xref>; Fruin and Rankin, <xref ref-type="bibr" rid="B17">2004</xref>; Jakicic et al., <xref ref-type="bibr" rid="B23">2004</xref>; King et al., <xref ref-type="bibr" rid="B25">2004</xref>; Mignault et al., <xref ref-type="bibr" rid="B34">2005</xref>; Papazoglou et al., <xref ref-type="bibr" rid="B36">2006</xref>; Malavolti et al., <xref ref-type="bibr" rid="B32">2007</xref>; Patel et al., <xref ref-type="bibr" rid="B37">2007</xref>; St-Onge et al., <xref ref-type="bibr" rid="B41">2007</xref>; Johannsen et al., <xref ref-type="bibr" rid="B24">2010</xref>; Casiraghi et al., <xref ref-type="bibr" rid="B6">2013</xref>; Brazeau et al., <xref ref-type="bibr" rid="B5">2016</xref>). When specific time periods of varying activity intensities were examined, however, the SWA generally overestimated EE at lower intensities, while EE was underestimated at higher intensities (Cole et al., <xref ref-type="bibr" rid="B7">2004</xref>; Fruin and Rankin, <xref ref-type="bibr" rid="B17">2004</xref>; Jakicic et al., <xref ref-type="bibr" rid="B23">2004</xref>; Patel et al., <xref ref-type="bibr" rid="B37">2007</xref>; Dwyer et al., <xref ref-type="bibr" rid="B13">2009</xref>; Berntsen et al., <xref ref-type="bibr" rid="B4">2010</xref>; Benito et al., <xref ref-type="bibr" rid="B3">2012</xref>; Gastin et al., <xref ref-type="bibr" rid="B18">2017</xref>). Accordingly, TDEE was overestimated in participants with low levels of TDEE and underestimated in participants with high TDEE (St-Onge et al., <xref ref-type="bibr" rid="B41">2007</xref>; Johannsen et al., <xref ref-type="bibr" rid="B24">2010</xref>).</p>
<p>It should further be considered that the accuracy of the SWA is impacted by external factors such as treadmill incline, exercise mode (e.g., running vs. bicycling), or the use of the upper vs. lower body exercise (Fruin and Rankin, <xref ref-type="bibr" rid="B17">2004</xref>; Jakicic et al., <xref ref-type="bibr" rid="B23">2004</xref>; Berntsen et al., <xref ref-type="bibr" rid="B4">2010</xref>; Vernillo et al., <xref ref-type="bibr" rid="B47">2015</xref>; Brazeau et al., <xref ref-type="bibr" rid="B5">2016</xref>; Gastin et al., <xref ref-type="bibr" rid="B18">2017</xref>). Specifically, underestimation of EE during uphill walking has been reported in several studies, with increasing measurement errors at steeper inclines (Fruin and Rankin, <xref ref-type="bibr" rid="B17">2004</xref>; Jakicic et al., <xref ref-type="bibr" rid="B23">2004</xref>; Vernillo et al., <xref ref-type="bibr" rid="B47">2015</xref>). Downhill walking, on the other hand, was associated with an overestimation of EE, and&#x02014;although less pronounced&#x02014;measurement errors increased as declines became steeper (Vernillo et al., <xref ref-type="bibr" rid="B47">2015</xref>). During stationary cycling, total EE did not differ between the SWA and IC, but individual time point data were poorly correlated: At the beginning of the cycling trial, EE was underestimated, but EE estimates by the SWA increased gradually over time even though IC values remained stable (Fruin and Rankin, <xref ref-type="bibr" rid="B17">2004</xref>; Brazeau et al., <xref ref-type="bibr" rid="B5">2016</xref>). Further, Gastin et al. (<xref ref-type="bibr" rid="B18">2017</xref>) reported an underestimation of EE during resistance type circuit exercise, most likely due to inaccuracies at higher intensities. In addition to problems related to activity type and intensity, body weight has been shown to affect measurement accuracy. Even though no particular bias toward over- or underestimation of EE was observed, measurement error increased with increasing BMI (Dwyer et al., <xref ref-type="bibr" rid="B13">2009</xref>; Malavolti et al., <xref ref-type="bibr" rid="B31">2012</xref>). Considering that athletes typically are on the extreme ends of the body composition spectrum (Meyer et al., <xref ref-type="bibr" rid="B33">2013</xref>), it is unclear to which degree body weight or composition contribute to measurement errors in athletes.</p>
<p>Differences in body weight or composition may also contribute to the considerable variability of measurement accuracy at the individual level (Fruin and Rankin, <xref ref-type="bibr" rid="B17">2004</xref>; Brazeau et al., <xref ref-type="bibr" rid="B5">2016</xref>). Nevertheless, a recent study reported accurate measurements of TDEE with a mean difference of 2.8 kcal/day and narrow 95% confidence intervals (&#x02212;34.8 to 40.3 kcal/day) and a correlation coefficient of <italic>r</italic> &#x0003D; 0.88 when comparing SWA values to DLW in 191 generally healthy adults with diverse body weight and physical activity levels (Drenowatz et al., <xref ref-type="bibr" rid="B11">2017</xref>). Overall, the SWA provides valid estimates of TDEE and ExEE with a measurement error of typically &#x0003C;10% in a recreationally active population.</p>
</sec>
<sec id="s4">
<title>Validity of the SenseWear armband during high-intensity exercise</title>
<p>To our knowledge, only one study has assessed the validity of SWA-measured TDEE specifically in athletes. Koehler et al. (<xref ref-type="bibr" rid="B27">2011</xref>) reported an average difference of 65 kcal/day (&#x0003C;2% of TDEE) between TDEE measured by SWA and DLW in 14 endurance trained athletes and a moderate to strong correlation (<italic>r</italic> &#x0003D; 0.73) However, higher levels of TDEE tended to be underestimated by the SWA, and the level of underestimation was related to the participant&#x00027;s exercise capacity, whereby EE was underestimated to a greater degree in better trained athletes (Koehler et al., <xref ref-type="bibr" rid="B27">2011</xref>).</p>
<sec>
<title>Validity during high-intensity aerobic exercise</title>
<p>Several studies have tested the validity of the SWA during high-intensity, continuous aerobic exercise. In two independent studies in trained male athletes, the SWA underestimated ExEE during treadmill running at speeds of &#x0007E;10.1 km/h (6.3 miles/h) and greater (Koehler et al., <xref ref-type="bibr" rid="B27">2011</xref>, <xref ref-type="bibr" rid="B28">2013</xref>). These findings were replicated by Drenowatz and Eisenmann (<xref ref-type="bibr" rid="B9">2011</xref>), who demonstrated that ExEE was consistently underestimated in endurance-trained athletes running at 65, 75, and 85% of their aerobic capacity, corresponding to a similar speed range (9.9&#x02013;14.6 km/h; 6.2&#x02013;9.1 miles/h). In another study, the SWA underestimated ExEE even at speeds from 6.0 to 7.2 km/h (3.7&#x02013;4.5 miles/h) (van Hoye et al., <xref ref-type="bibr" rid="B46">2014</xref>). Similar findings were also reported during stationary bicycling, whereby the SWA underestimated ExEE at workloads between 140 and 380 W (Koehler et al., <xref ref-type="bibr" rid="B27">2011</xref>). In all cases, the level of underestimation increased with increasing exercise intensity (Drenowatz and Eisenmann, <xref ref-type="bibr" rid="B9">2011</xref>; Koehler et al., <xref ref-type="bibr" rid="B27">2011</xref>, <xref ref-type="bibr" rid="B28">2013</xref>; van Hoye et al., <xref ref-type="bibr" rid="B46">2014</xref>). However, visual inspection of the combined data from all five studies (Figure <xref ref-type="fig" rid="F2">2</xref>) suggests that differences between SWA and IC are rather modest at low-to-moderate exercise intensities. At exercise intensities above 35 mL/kg/min (10 METs) SWA-measured ExEE, however, tends to plateau whereas IC-measured ExEE increases continuously, resulting in a stark increase in the level of underestimation. It is noteworthy that all studies employed an incremental exercise test to assess the validity of the SWA at multiple exercise intensities. To our knowledge, only one study separately used a 30 min exercise bout at a self-selected intensity, resulting in a similar level of underestimation of 27% (Drenowatz and Eisenmann, <xref ref-type="bibr" rid="B9">2011</xref>).</p>
<fig id="F2" position="float">
<label>Figure 2</label>
<caption><p>Previously published data reporting the discrepancy between energy expenditure measured with the SenseWear armband (black symbols) in comparison to the reference method (indirect calorimetry; open symbols) and the difference between SenseWear and indirect calorimetry (gray symbols). The dotted line depicts an exercise intensity of 35 mL/kg/min (10 METs). Data published by Drenowatz and Eisenmann (<xref ref-type="bibr" rid="B9">2011</xref>) stem from 20 male and female runners (VO<sub>2peak</sub>: 57 mL/kg/min); Data published by Koehler et al. (<xref ref-type="bibr" rid="B27">2011</xref>) stem from 14 triathletes (VO<sub>2peak</sub>: 58 mL/kg/min) who were assessed while running and biking; Data published by Koehler et al. (<xref ref-type="bibr" rid="B28">2013</xref>) stem from 19 endurance and strength trained men (VO<sub>2peak</sub>: 55 mL/kg/min) who were assessed while running; Data from van Hoye et al. (<xref ref-type="bibr" rid="B46">2014</xref>) stem from 23 male kinesiology students (VO<sub>2peak</sub>: 69 mL/kg/min) and 20 female kinesiology students (VO<sub>2peak</sub>: 53 mL/kg/min) who were assessed while walking and running; Data published by Van Hoye et al. (<xref ref-type="bibr" rid="B45">2015</xref>) stem from 39 male and female kinesiology students (VO<sub>2peak</sub>: 58 mL/kg/min) who were assessed while walking and running.</p></caption>
<graphic xlink:href="fphys-08-00983-g0002.tif"/>
</fig>
</sec>
<sec>
<title>Validity during resistance exercise</title>
<p>Only few studies have examined the accuracy of the SWA during resistance-type exercise. Benito et al. (<xref ref-type="bibr" rid="B3">2012</xref>) reported an underestimation of ExEE during circuit-type resistance training at 30, 50, and 70% of the 15RMmax in a mixed sample of 29 recreationally active participants. Compared to IC, SWA-estimated ExEE was 32% lower in men, corresponding to a difference of 2.3 METs, and 21% lower in women (1.1 METs). Furthermore, the degree of underestimation increased with increasing exercise intensity, although this effect was only significant in men (Benito et al., <xref ref-type="bibr" rid="B3">2012</xref>). On the other hand, the SWA slightly overestimated exercise EE by an average 35 kcal per session during self-selected resistance exercise in a mixed sample of 52 participants of varying age and fitness level (Bai et al., <xref ref-type="bibr" rid="B2">2016</xref>). The measurement error at the individual level was reported at 15%. However, the average exercise intensity was rather low during these sessions (3.2 METs) and may not resemble a typical resistance exercise session in athletic populations. Using a more traditional resistance training protocol of 9 exercises covering all major muscle groups with 3 sets of 10 repetitions at 70% of the 1-reptition maximum, the SWA provided accurate estimates of ExEE with an error of less than 5% and a strong correlation for ExEE (<italic>r</italic> &#x0003D; 0.77) and TDEE (<italic>r</italic> &#x0003D; 0.97) (Reeve et al., <xref ref-type="bibr" rid="B38">2014</xref>). Measurement errors also remained constant across the ExEE spectrum with an almost perfect reliability of the SWA (test-retest <italic>r</italic> &#x0003D; 0.96). It should, however, be considered that ExEE was integrated over the course of the exercise bout; no information was provided on the measurement accuracy for specific exercise types (Reeve et al., <xref ref-type="bibr" rid="B38">2014</xref>).</p>
</sec>
<sec>
<title>Validity during mixed exercise forms</title>
<p>Similar to studies addressing resistance-type exercise, there has been only limited research examining the accuracy of the SWA during mixed exercise forms, particularly in athletic populations. Zanetti et al. (<xref ref-type="bibr" rid="B55">2014</xref>) assessed the accuracy of the SWA during a 42-min sport-specific intermittent exercise trial in 14 male rugby players. While there was no clear trend toward over- or underestimation of ExEE with a mean bias of &#x02212;0.2 kcal/min (&#x02212;1.9%), results revealed only a moderate correlation between the SWA and IC (<italic>r</italic> &#x0003D; 0.55). During a 30-min basketball-specific skill session, the SWA, however, was shown to underestimate ExEE by 1.1 kcal/min (15%) (Taylor, <xref ref-type="bibr" rid="B42">2012</xref>). EE during recovery period following intermittent exercise training, on the other hand, was overestimated by 17% by the SWA when compared to IC (Zanetti et al., <xref ref-type="bibr" rid="B55">2014</xref>).</p>
</sec>
</sec>
<sec id="s5">
<title>Limitations of the SenseWear armband: algorithm vs. methodology</title>
<p>Despite the tendency to underestimate ExEE during high-intensity exercise, available data suggest that the SWA can reliably detect activity patterns, rest periods, and varying levels of exercise intensity within individuals. For example, significant intra-individual correlations between IC and SWA was reported in 90% of endurance athletes who ran at exercise intensities between 65 and 85% VO<sub>2max</sub> (Drenowatz and Eisenmann, <xref ref-type="bibr" rid="B9">2011</xref>). In another study involving incremental treadmill running at speeds between 10.8 and 17.3 km/h, raw data including acceleration counts, and particularly counts in the longitudinal plane, increased continuously as workload increased (Koehler et al., <xref ref-type="bibr" rid="B28">2013</xref>), demonstrating that the technology is suited to detect movement patterns even at higher exercise intensities. Consequently, limitations to the proprietary algorithm are a candidate source for the underestimation of ExEE during high-intensity exercise. Several studies have tested whether algorithm adjustments could improve the validity of the SWA during exercise. In one of the first published validation studies, Jakicic et al. (<xref ref-type="bibr" rid="B23">2004</xref>) reported that the accuracy of the SWA improved after algorithm revisions. After the initial algorithm underestimated ExEE during walking, stepping, and cycling by 7&#x02013;29% and overestimated ExEE during arm ergometry by 29%, the researchers provided a subset of their data to develop exercise-specific proprietary equations, which reduced errors in ExEE measured by the SWA to a non-significant level. However, ExEE values, which peaked during stair stepping at 5.3&#x02013;9.2 kcal/min, did not exceed the 10 MET-threshold. More recently, Van Hoye et al. (<xref ref-type="bibr" rid="B45">2015</xref>) compared two different algorithms during low- and moderate-intensity treadmill running in well-trained students, reasoning that a newer algorithm would provide more accurate estimates of EE as the manufacturer updates proprietary algorithms on a regular basis. When compared to the initially used algorithm (version 2.2.), data processed using a newer algorithm (version 5.2) reduced the measurement error from 18&#x02013;24 to 5&#x02013;17%, although ExEE remained underestimated.</p>
</sec>
<sec id="s6">
<title>Application of the SenseWear armband in athletic populations</title>
<p>Despite the previously mentioned limitations, several groups have used the SWA to track EE in athletes. In adolescent sprinters undergoing high-intensity exercise training, Aerenhouts et al. (<xref ref-type="bibr" rid="B1">2011</xref>) measured TDEE, ExEE, and activity patterns using the SWA. When compared to self-report, the SWA registered less time spent in high-intensity activity, although this difference did not result in differences in TDEE, which was within 6% of the TDEE derived from activity diaries. The authors also highlighted the need for additional information when athletes fail to wear the SWA for 24 h. The SWA was also used to record ExEE during the competitive season in volleyball players (Woodruff and Meloche, <xref ref-type="bibr" rid="B54">2013</xref>). SWA-recorded ExEE was found to be higher during games when compared to practice and warm-up sessions. Combining SWA data with diet logs and body composition assessment, the authors further concluded that the majority of the athletes were in an energy-balanced state. Using the SWA to quantify non-exercise activity thermogenesis (NEAT) among endurance athletes undergoing periods of high and low training volume, Drenowatz et al. (<xref ref-type="bibr" rid="B10">2013</xref>) demonstrated that the high training volume did not result in a compensatory reduction in NEAT; instead, athletes reduced their sedentary activities to allow for more training time. In professional Australian Football players, the SWA was used to document the contribution of NEAT to TDEE, which was greater on training days (85%) when compared to match days (69%) (Walker et al., <xref ref-type="bibr" rid="B48">2016</xref>).</p>
<p>Because the SWA can be worn continuously for several days, it has also been used for the assessment of sleep quantity and quality. In male elite rugby union players, SWA-derived sleep duration was shown to be lower during game nights when compared to non-game nights, although sleep efficiency was not different (Eagles and Lovell, <xref ref-type="bibr" rid="B14">2016</xref>). In another trial comparing high-intensity interval training to strength training, SWA-derived sleep efficiency was lower in the high-intensity interval condition (K&#x000F6;lling et al., <xref ref-type="bibr" rid="B29">2016</xref>). These applications demonstrate that the SWA is well-suited to capture other biological factors, such as characteristics of sleep and NEAT, that may have important implications for athletic performance.</p>
</sec>
<sec id="s7">
<title>Conclusion and summary</title>
<p>Considering that the SWA has been designed for a broad market, it is not surprising that the device tends to underestimate ExEE for periods of high-intensity exercise. Although most data has been established for aerobic exercise, the SWA seems to equally underestimate ExEE during other exercise forms. When energy expenditure is integrated over longer time periods, including rest and recovery, the measurement error becomes less pronounced and estimations of TDEE tend to be more accurate, even in athletic populations. Adjustments to the proprietary algorithm that is used to derive EE may further help to improve the validity of the SWA. Unfortunately the sale of the SWA has been terminated. Recently, a new disposable device with similar functionality has been introduced but is not available for commercial application at this time (Welk et al., <xref ref-type="bibr" rid="B50">2017</xref>). Another viable option is the combination of GPS data with accelerometry and heart rate to assess EE in outdoor sports (Costa et al., <xref ref-type="bibr" rid="B8">2015</xref>), although the accuracy of such devices remains to be explored. Given the current lack of alternatives, the SWA continues to be used in research and practice, emphasizing the need for the continued development of wearable devices that reliably measure EE and related variables in athletic settings.</p>
</sec>
<sec id="s8">
<title>Author contributions</title>
<p>All authors listed have made a substantial, direct and intellectual contribution to the work, and approved it for publication.</p>
<sec>
<title>Conflict of interest statement</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
</sec>
</body>
<back>
<ref-list>
<title>References</title>
<ref id="B1">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Aerenhouts</surname> <given-names>D.</given-names></name> <name><surname>Zinzen</surname> <given-names>E.</given-names></name> <name><surname>Clarys</surname> <given-names>P.</given-names></name></person-group> (<year>2011</year>). <article-title>Energy expenditure and habitual physical activities in adolescent sprint athletes</article-title>. <source>J. Sports Sci. Med.</source> <volume>10</volume>, <fpage>362</fpage>&#x02013;<lpage>368</lpage>. <pub-id pub-id-type="pmid">24149884</pub-id></citation></ref>
<ref id="B2">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bai</surname> <given-names>Y.</given-names></name> <name><surname>Welk</surname> <given-names>G. J.</given-names></name> <name><surname>Nam</surname> <given-names>Y. H.</given-names></name> <name><surname>Lee</surname> <given-names>J. A.</given-names></name> <name><surname>Lee</surname> <given-names>J. M.</given-names></name> <name><surname>Kim</surname> <given-names>Y.</given-names></name> <etal/></person-group>. (<year>2016</year>). <article-title>Comparison of consumer and research monitors under semistructured settings</article-title>. <source>Med. Sci. Sports Exerc.</source> <volume>48</volume>, <fpage>151</fpage>&#x02013;<lpage>158</lpage>. <pub-id pub-id-type="doi">10.1249/MSS.0000000000000727</pub-id><pub-id pub-id-type="pmid">26154336</pub-id></citation></ref>
<ref id="B3">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Benito</surname> <given-names>P. J.</given-names></name> <name><surname>Neiva</surname> <given-names>C.</given-names></name> <name><surname>Gonz&#x000E1;lez-Quijano</surname> <given-names>P. S.</given-names></name> <name><surname>Cupeiro</surname> <given-names>R.</given-names></name> <name><surname>Morencos</surname> <given-names>E.</given-names></name> <name><surname>Peinado</surname> <given-names>A. B.</given-names></name></person-group> (<year>2012</year>). <article-title>Validation of the sensewear armband in circuit resistance training with different loads</article-title>. <source>Eur. J. Appl. Physiol.</source> <volume>112</volume>, <fpage>3155</fpage>&#x02013;<lpage>3159</lpage>. <pub-id pub-id-type="doi">10.1007/s00421-011-2269-5</pub-id><pub-id pub-id-type="pmid">22143845</pub-id></citation></ref>
<ref id="B4">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Berntsen</surname> <given-names>S.</given-names></name> <name><surname>Hageberg</surname> <given-names>R.</given-names></name> <name><surname>Aandstad</surname> <given-names>A.</given-names></name> <name><surname>Mowinckel</surname> <given-names>P.</given-names></name> <name><surname>Anderssen</surname> <given-names>S. A.</given-names></name> <name><surname>Carlsen</surname> <given-names>K. H.</given-names></name> <etal/></person-group>. (<year>2010</year>). <article-title>Validity of physical activity monitors in adults participating in free-living activities</article-title>. <source>Br. J. Sports Med.</source> <volume>44</volume>, <fpage>657</fpage>&#x02013;<lpage>664</lpage>. <pub-id pub-id-type="doi">10.1136/bjsm.2008.048868</pub-id><pub-id pub-id-type="pmid">18628358</pub-id></citation></ref>
<ref id="B5">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Brazeau</surname> <given-names>A. S.</given-names></name> <name><surname>Beaudoin</surname> <given-names>N.</given-names></name> <name><surname>B&#x000E9;lisle</surname> <given-names>V.</given-names></name> <name><surname>Messier</surname> <given-names>V.</given-names></name> <name><surname>Karelis</surname> <given-names>A. D.</given-names></name> <name><surname>Rabasa-Lhoret</surname> <given-names>R.</given-names></name></person-group> (<year>2016</year>). <article-title>Validation and reliability of two activity monitors for energy expenditure assessment</article-title>. <source>J. Sci. Med. Sport</source> <volume>19</volume>, <fpage>46</fpage>&#x02013;<lpage>50</lpage>. <pub-id pub-id-type="doi">10.1016/j.jsams.2014.11.001</pub-id><pub-id pub-id-type="pmid">25466490</pub-id></citation></ref>
<ref id="B6">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Casiraghi</surname> <given-names>F.</given-names></name> <name><surname>Lertwattanarak</surname> <given-names>R.</given-names></name> <name><surname>Luzi</surname> <given-names>L.</given-names></name> <name><surname>Chavez</surname> <given-names>A. O.</given-names></name> <name><surname>Davalli</surname> <given-names>A. M.</given-names></name> <name><surname>Naegelin</surname> <given-names>T.</given-names></name> <etal/></person-group>. (<year>2013</year>). <article-title>Energy expenditure evaluation in humans and non-human primates by sensewear armband. Validation of energy expenditure evaluation by sensewear armband by direct comparison with indirect calorimetry</article-title>. <source>PLoS ONE</source> <volume>8</volume>:<fpage>e73651</fpage>. <pub-id pub-id-type="doi">10.1371/journal.pone.0073651</pub-id><pub-id pub-id-type="pmid">24069218</pub-id></citation></ref>
<ref id="B7">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Cole</surname> <given-names>P. J.</given-names></name> <name><surname>LeMura</surname> <given-names>L. M.</given-names></name> <name><surname>Klinger</surname> <given-names>T. A.</given-names></name> <name><surname>Strohecker</surname> <given-names>K.</given-names></name> <name><surname>McConnell</surname> <given-names>T. R.</given-names></name></person-group> (<year>2004</year>). <article-title>Measuring energy expenditure in cardiac patients using the body media armband versus indirect calorimetry. A validation study</article-title>. <source>J. Sports Med. Phys. Fitness</source> <volume>44</volume>, <fpage>262</fpage>&#x02013;<lpage>271</lpage>. <pub-id pub-id-type="pmid">15756165</pub-id></citation></ref>
<ref id="B8">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Costa</surname> <given-names>S.</given-names></name> <name><surname>Ogilvie</surname> <given-names>D.</given-names></name> <name><surname>Dalton</surname> <given-names>A.</given-names></name> <name><surname>Westgate</surname> <given-names>K.</given-names></name> <name><surname>Brage</surname> <given-names>S.</given-names></name> <name><surname>Panter</surname> <given-names>J.</given-names></name></person-group> (<year>2015</year>). <article-title>Quantifying the physical activity energy expenditure of commuters using a combination of global positioning system and combined heart rate and movement sensors</article-title>. <source>Prev. Med.</source> <volume>81</volume>, <fpage>339</fpage>&#x02013;<lpage>344</lpage>. <pub-id pub-id-type="doi">10.1016/j.ypmed.2015.09.022</pub-id><pub-id pub-id-type="pmid">26441297</pub-id></citation></ref>
<ref id="B9">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Drenowatz</surname> <given-names>C.</given-names></name> <name><surname>Eisenmann</surname> <given-names>J. C.</given-names></name></person-group> (<year>2011</year>). <article-title>Validation of the sensewear armband at high intensity exercise</article-title>. <source>Eur. J. Appl. Physiol.</source> <volume>111</volume>, <fpage>883</fpage>&#x02013;<lpage>887</lpage>. <pub-id pub-id-type="doi">10.1007/s00421-010-1695-0</pub-id><pub-id pub-id-type="pmid">20972880</pub-id></citation></ref>
<ref id="B10">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Drenowatz</surname> <given-names>C.</given-names></name> <name><surname>Eisenmann</surname> <given-names>J. C.</given-names></name> <name><surname>Pivarnik</surname> <given-names>J. M.</given-names></name> <name><surname>Pfeiffer</surname> <given-names>K. A.</given-names></name> <name><surname>Carlson</surname> <given-names>J. J.</given-names></name></person-group> (<year>2013</year>). <article-title>Differences in energy expenditure between high- and low-volume training</article-title>. <source>Eur. J. Sport Sci.</source> <volume>13</volume>, <fpage>422</fpage>&#x02013;<lpage>430</lpage>. <pub-id pub-id-type="doi">10.1080/17461391.2011.635707</pub-id><pub-id pub-id-type="pmid">23834549</pub-id></citation></ref>
<ref id="B11">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Drenowatz</surname> <given-names>C.</given-names></name> <name><surname>Hill</surname> <given-names>J. O.</given-names></name> <name><surname>Peters</surname> <given-names>J. C.</given-names></name> <name><surname>Soriano-Maldonado</surname> <given-names>A.</given-names></name> <name><surname>Blair</surname> <given-names>S. N.</given-names></name></person-group> (<year>2017</year>). <article-title>The association of change in physical activity and body weight in the regulation of total energy expenditure</article-title>. <source>Eur. J. Clin. Nutr.</source> <volume>71</volume>, <fpage>377</fpage>&#x02013;<lpage>382</lpage>. <pub-id pub-id-type="doi">10.1038/ejcn.2016.228</pub-id><pub-id pub-id-type="pmid">27966573</pub-id></citation></ref>
<ref id="B12">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>D&#x000FC;king</surname> <given-names>P.</given-names></name> <name><surname>Hotho</surname> <given-names>A.</given-names></name> <name><surname>Holmberg</surname> <given-names>H. C.</given-names></name> <name><surname>Fuss</surname> <given-names>F. K.</given-names></name> <name><surname>Sperlich</surname> <given-names>B.</given-names></name></person-group> (<year>2016</year>). <article-title>Comparison of non-invasive individual monitoring of the training and health of athletes with commercially available wearable technologies</article-title>. <source>Front. Physiol.</source> <volume>7</volume>:<fpage>71</fpage>. <pub-id pub-id-type="doi">10.3389/fphys.2016.00071</pub-id><pub-id pub-id-type="pmid">27014077</pub-id></citation></ref>
<ref id="B13">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dwyer</surname> <given-names>T. J.</given-names></name> <name><surname>Alison</surname> <given-names>J. A.</given-names></name> <name><surname>McKeough</surname> <given-names>Z. J.</given-names></name> <name><surname>Elkins</surname> <given-names>M. R.</given-names></name> <name><surname>Bye</surname> <given-names>P. T.</given-names></name></person-group> (<year>2009</year>). <article-title>Evaluation of the sensewear activity monitor during exercise in cystic fibrosis and in health</article-title>. <source>Respir. Med.</source> <volume>103</volume>, <fpage>1511</fpage>&#x02013;<lpage>1517</lpage>. <pub-id pub-id-type="doi">10.1016/j.rmed.2009.04.013</pub-id><pub-id pub-id-type="pmid">19464863</pub-id></citation></ref>
<ref id="B14">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Eagles</surname> <given-names>A. N.</given-names></name> <name><surname>Lovell</surname> <given-names>D. I.</given-names></name></person-group> (<year>2016</year>). <article-title>Changes in sleep quantity and efficiency in professional rugby union players during home-based training and match play</article-title>. <source>J. Sports Med. Phys. Fitness</source> <volume>56</volume>, <fpage>565</fpage>&#x02013;<lpage>571</lpage>. <pub-id pub-id-type="pmid">27285344</pub-id></citation></ref>
<ref id="B15">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ebine</surname> <given-names>N.</given-names></name> <name><surname>Rafamantanantsoa</surname> <given-names>H. H.</given-names></name> <name><surname>Nayuki</surname> <given-names>Y.</given-names></name> <name><surname>Yamanaka</surname> <given-names>K.</given-names></name> <name><surname>Tashima</surname> <given-names>K.</given-names></name> <name><surname>Ono</surname> <given-names>T.</given-names></name> <etal/></person-group>. (<year>2002</year>). <article-title>Measurement of total energy expenditure by the doubly labelled water method in professional soccer players</article-title>. <source>J. Sports Sci.</source> <volume>20</volume>, <fpage>391</fpage>&#x02013;<lpage>397</lpage>. <pub-id pub-id-type="doi">10.1080/026404102317366645</pub-id><pub-id pub-id-type="pmid">12043828</pub-id></citation></ref>
<ref id="B16">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ekelund</surname> <given-names>U.</given-names></name> <name><surname>Yngve</surname> <given-names>A.</given-names></name> <name><surname>Westerterp</surname> <given-names>K.</given-names></name> <name><surname>Sj&#x000F6;str&#x000F6;m</surname> <given-names>M.</given-names></name></person-group> (<year>2002</year>). <article-title>Energy expenditure assessed by heart rate and doubly labeled water in young athletes</article-title>. <source>Med. Sci. Sports Exerc.</source> <volume>34</volume>, <fpage>1360</fpage>&#x02013;<lpage>1366</lpage>. <pub-id pub-id-type="doi">10.1097/00005768-200208000-00019</pub-id><pub-id pub-id-type="pmid">12165693</pub-id></citation></ref>
<ref id="B17">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fruin</surname> <given-names>M. L.</given-names></name> <name><surname>Rankin</surname> <given-names>J. W.</given-names></name></person-group> (<year>2004</year>). <article-title>Validity of a multi-sensor armband in estimating rest and exercise energy expenditure</article-title>. <source>Med. Sci. Sports Exerc.</source> <volume>36</volume>, <fpage>1063</fpage>&#x02013;<lpage>1069</lpage>. <pub-id pub-id-type="doi">10.1249/01.MSS.0000128144.91337.38</pub-id><pub-id pub-id-type="pmid">15179178</pub-id></citation></ref>
<ref id="B18">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gastin</surname> <given-names>P. B.</given-names></name> <name><surname>Cayzer</surname> <given-names>C.</given-names></name> <name><surname>Dwyer</surname> <given-names>D.</given-names></name> <name><surname>Robertson</surname> <given-names>S.</given-names></name></person-group> (<year>2017</year>). <article-title>Validity of the ActiGraph GT3X&#x0002B; and bodymedia sensewear armband to estimate energy expenditure during physical activity and sport</article-title>. <source>J. Sci. Med. Sport.</source> [Epub ahead of print]. <pub-id pub-id-type="doi">10.1016/j.jsams.2017.07.022</pub-id><pub-id pub-id-type="pmid">28797831</pub-id></citation></ref>
<ref id="B19">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Haugen</surname> <given-names>H. A.</given-names></name> <name><surname>Chan</surname> <given-names>L. N.</given-names></name> <name><surname>Li</surname> <given-names>F.</given-names></name></person-group> (<year>2007</year>). <article-title>Indirect calorimetry: a practical guide for clinicians</article-title>. <source>Nutr. Clin. Pract.</source> <volume>22</volume>, <fpage>377</fpage>&#x02013;<lpage>388</lpage>. <pub-id pub-id-type="doi">10.1177/0115426507022004377</pub-id><pub-id pub-id-type="pmid">17644692</pub-id></citation></ref>
<ref id="B20">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hill</surname> <given-names>R. J.</given-names></name> <name><surname>Davies</surname> <given-names>P. S.</given-names></name></person-group> (<year>2001</year>). <article-title>The validity of self-reported energy intake as determined using the doubly labelled water technique</article-title>. <source>Br. J. Nutr.</source> <volume>85</volume>, <fpage>415</fpage>&#x02013;<lpage>430</lpage>. <pub-id pub-id-type="doi">10.1079/BJN2000281</pub-id><pub-id pub-id-type="pmid">11348556</pub-id></citation></ref>
<ref id="B21">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hill</surname> <given-names>R. J.</given-names></name> <name><surname>Davies</surname> <given-names>P. S.</given-names></name></person-group> (<year>2002</year>). <article-title>Energy intake and energy expenditure in elite lightweight female rowers</article-title>. <source>Med. Sci. Sports Exerc.</source> <volume>34</volume>, <fpage>1823</fpage>&#x02013;<lpage>1829</lpage>. <pub-id pub-id-type="doi">10.1097/00005768-200211000-00020</pub-id><pub-id pub-id-type="pmid">12439089</pub-id></citation></ref>
<ref id="B22">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jaeschke</surname> <given-names>L.</given-names></name> <name><surname>Luzak</surname> <given-names>A.</given-names></name> <name><surname>Steinbrecher</surname> <given-names>A.</given-names></name> <name><surname>Jeran</surname> <given-names>S.</given-names></name> <name><surname>Ferland</surname> <given-names>M.</given-names></name> <name><surname>Linkohr</surname> <given-names>B.</given-names></name> <etal/></person-group>. (<year>2017</year>). <article-title>24 h-accelerometry in epidemiological studies: automated detection of non-wear time in comparison to diary information</article-title>. <source>Sci. Rep.</source> <volume>7</volume>:<fpage>2227</fpage>. <pub-id pub-id-type="doi">10.1038/s41598-017-01092-w</pub-id><pub-id pub-id-type="pmid">28533553</pub-id></citation></ref>
<ref id="B23">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jakicic</surname> <given-names>J. M.</given-names></name> <name><surname>Marcus</surname> <given-names>M.</given-names></name> <name><surname>Gallagher</surname> <given-names>K. I.</given-names></name> <name><surname>Randall</surname> <given-names>C.</given-names></name> <name><surname>Thomas</surname> <given-names>E.</given-names></name> <name><surname>Goss</surname> <given-names>F. L.</given-names></name> <etal/></person-group>. (<year>2004</year>). <article-title>Evaluation of the sensewear pro Armband to assess energy expenditure during exercise</article-title>. <source>Med. Sci. Sports Exerc.</source> <volume>36</volume>, <fpage>897</fpage>&#x02013;<lpage>904</lpage>. <pub-id pub-id-type="doi">10.1249/01.MSS.0000126805.32659.43</pub-id><pub-id pub-id-type="pmid">15126727</pub-id></citation></ref>
<ref id="B24">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Johannsen</surname> <given-names>D. L.</given-names></name> <name><surname>Calabro</surname> <given-names>M. A.</given-names></name> <name><surname>Stewart</surname> <given-names>J.</given-names></name> <name><surname>Franke</surname> <given-names>W.</given-names></name> <name><surname>Rood</surname> <given-names>J. C.</given-names></name> <name><surname>Welk</surname> <given-names>G. J.</given-names></name></person-group> (<year>2010</year>). <article-title>Accuracy of armband monitors for measuring daily energy expenditure in healthy adults</article-title>. <source>Med. Sci. Sports Exerc.</source> <volume>42</volume>, <fpage>2134</fpage>&#x02013;<lpage>2140</lpage>. <pub-id pub-id-type="doi">10.1249/MSS.0b013e3181e0b3ff</pub-id><pub-id pub-id-type="pmid">20386334</pub-id></citation></ref>
<ref id="B25">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>King</surname> <given-names>G. A.</given-names></name> <name><surname>Torres</surname> <given-names>N.</given-names></name> <name><surname>Potter</surname> <given-names>C.</given-names></name> <name><surname>Brooks</surname> <given-names>T. J.</given-names></name> <name><surname>Coleman</surname> <given-names>K. J.</given-names></name></person-group> (<year>2004</year>). <article-title>Comparison of activity monitors to estimate energy cost of treadmill exercise</article-title>. <source>Med. Sci. Sports Exerc.</source> <volume>36</volume>, <fpage>1244</fpage>&#x02013;<lpage>1251</lpage>. <pub-id pub-id-type="doi">10.1249/01.MSS.0000132379.09364.F8</pub-id><pub-id pub-id-type="pmid">15235333</pub-id></citation></ref>
<ref id="B26">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Koehler</surname> <given-names>K.</given-names></name> <name><surname>Braun</surname> <given-names>H.</given-names></name> <name><surname>De Marees</surname> <given-names>M.</given-names></name> <name><surname>Fusch</surname> <given-names>G.</given-names></name> <name><surname>Fusch</surname> <given-names>C.</given-names></name> <name><surname>Mester</surname> <given-names>J.</given-names></name> <etal/></person-group>. (<year>2010</year>). <article-title>Parallel assessment of nutrition and activity in athletes: validation against doubly labelled water, 24-h urea excretion, and indirect calorimetry</article-title>. <source>J. Sports Sci.</source> <volume>28</volume>, <fpage>1435</fpage>&#x02013;<lpage>1449</lpage>. <pub-id pub-id-type="doi">10.1080/02640414.2010.513482</pub-id><pub-id pub-id-type="pmid">20967672</pub-id></citation></ref>
<ref id="B27">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Koehler</surname> <given-names>K.</given-names></name> <name><surname>Braun</surname> <given-names>H.</given-names></name> <name><surname>Mar&#x000E9;es</surname> <given-names>M.</given-names></name> <name><surname>Fusch</surname> <given-names>G.</given-names></name> <name><surname>Fusch</surname> <given-names>C.</given-names></name> <name><surname>Schaenzer</surname> <given-names>W.</given-names></name></person-group> (<year>2011</year>). <article-title>Assessing energy expenditure in male endurance athletes: validity of the sensewear armband</article-title>. <source>Med. Sci. Sports Exerc.</source> <volume>43</volume>, <fpage>1328</fpage>&#x02013;<lpage>1333</lpage>. <pub-id pub-id-type="doi">10.1249/MSS.0b013e31820750f5</pub-id><pub-id pub-id-type="pmid">21131865</pub-id></citation></ref>
<ref id="B28">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Koehler</surname> <given-names>K.</given-names></name> <name><surname>Marees</surname> <given-names>M.</given-names></name> <name><surname>Braun</surname> <given-names>H.</given-names></name> <name><surname>Schaenzer</surname> <given-names>W.</given-names></name></person-group> (<year>2013</year>). <article-title>Evaluation of two portable sensors for energy expenditure assessment during high-intensity running</article-title>. <source>Eur. J. Sport Sci.</source> <volume>13</volume>, <fpage>31</fpage>&#x02013;<lpage>41</lpage>. <pub-id pub-id-type="doi">10.1080/17461391.2011.586439</pub-id></citation></ref>
<ref id="B29">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>K&#x000F6;lling</surname> <given-names>S.</given-names></name> <name><surname>Wiewelhove</surname> <given-names>T.</given-names></name> <name><surname>Raeder</surname> <given-names>C.</given-names></name> <name><surname>Endler</surname> <given-names>S.</given-names></name> <name><surname>Ferrauti</surname> <given-names>A.</given-names></name> <name><surname>Meyer</surname> <given-names>T.</given-names></name> <etal/></person-group>. (<year>2016</year>). <article-title>Sleep monitoring of a six-day microcycle in strength and high-intensity training</article-title>. <source>Eur. J. Sport Sci.</source> <volume>16</volume>, <fpage>507</fpage>&#x02013;<lpage>515</lpage>. <pub-id pub-id-type="doi">10.1080/17461391.2015.1041062</pub-id><pub-id pub-id-type="pmid">26062597</pub-id></citation></ref>
<ref id="B30">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Loucks</surname> <given-names>A. B.</given-names></name> <name><surname>Kiens</surname> <given-names>B.</given-names></name> <name><surname>Wright</surname> <given-names>H. H.</given-names></name></person-group> (<year>2011</year>). <article-title>Energy availability in athletes</article-title>. <source>J. Sports Sci.</source> <volume>29</volume>(<supplement>Suppl. 1</supplement>), <fpage>S7</fpage>&#x02013;<lpage>S15</lpage>. <pub-id pub-id-type="doi">10.1080/02640414.2011.588958</pub-id><pub-id pub-id-type="pmid">21793767</pub-id></citation></ref>
<ref id="B31">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Malavolti</surname> <given-names>M.</given-names></name> <name><surname>Bellentani</surname> <given-names>S.</given-names></name> <name><surname>Pietrobelli</surname> <given-names>A.</given-names></name> <name><surname>Tardini</surname> <given-names>L.</given-names></name> <name><surname>Bellucci</surname> <given-names>A.</given-names></name> <name><surname>Busacchi</surname> <given-names>M.</given-names></name> <etal/></person-group>. (<year>2012</year>). <article-title>Reliability of a multisensor armband in estimating energy expenditure according to degree of obesity</article-title>. <source>J. Obes. Weight Loss Ther.</source> <volume>2</volume>:<fpage>116</fpage>. <pub-id pub-id-type="doi">10.4172/2165-7904.1000116</pub-id></citation></ref>
<ref id="B32">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Malavolti</surname> <given-names>M.</given-names></name> <name><surname>Pietrobelli</surname> <given-names>A.</given-names></name> <name><surname>Dugoni</surname> <given-names>M.</given-names></name> <name><surname>Poli</surname> <given-names>M.</given-names></name> <name><surname>Romagnoli</surname> <given-names>E.</given-names></name> <name><surname>De Cristofaro</surname> <given-names>P.</given-names></name> <etal/></person-group>. (<year>2007</year>). <article-title>A new device for measuring resting energy expenditure (REE) in healthy subjects</article-title>. <source>Nutr. Metab. Cardiovasc. Dis.</source> <volume>17</volume>, <fpage>338</fpage>&#x02013;<lpage>343</lpage>. <pub-id pub-id-type="doi">10.1016/j.numecd.2005.12.009</pub-id><pub-id pub-id-type="pmid">17562571</pub-id></citation></ref>
<ref id="B33">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Meyer</surname> <given-names>N. L.</given-names></name> <name><surname>Sundgot-Borgen</surname> <given-names>J.</given-names></name> <name><surname>Lohman</surname> <given-names>T. G.</given-names></name> <name><surname>Ackland</surname> <given-names>T. R.</given-names></name> <name><surname>Stewart</surname> <given-names>A. D.</given-names></name> <name><surname>Maughan</surname> <given-names>R. J.</given-names></name> <etal/></person-group>. (<year>2013</year>). <article-title>Body composition for health and performance: a survey of body composition assessment practice carried out by the ad hoc research working group on body composition, health and performance under the auspices of the IOC medical commission</article-title>. <source>Br. J. Sports Med.</source> <volume>47</volume>, <fpage>1044</fpage>&#x02013;<lpage>1053</lpage>. <pub-id pub-id-type="doi">10.1136/bjsports-2013-092561</pub-id><pub-id pub-id-type="pmid">24065075</pub-id></citation></ref>
<ref id="B34">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mignault</surname> <given-names>D.</given-names></name> <name><surname>St-Onge</surname> <given-names>M.</given-names></name> <name><surname>Karelis</surname> <given-names>A. D.</given-names></name> <name><surname>Allison</surname> <given-names>D. B.</given-names></name> <name><surname>Rabasa-Lhoret</surname> <given-names>R.</given-names></name></person-group> (<year>2005</year>). <article-title>Evaluation of the portable healthwear armband: a device to measure total daily energy expenditure in free-living type 2 diabetic individuals</article-title>. <source>Diabetes Care</source> <volume>28</volume>, <fpage>225</fpage>&#x02013;<lpage>227</lpage>. <pub-id pub-id-type="doi">10.2337/diacare.28.1.225-a</pub-id><pub-id pub-id-type="pmid">15616258</pub-id></citation></ref>
<ref id="B35">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ndahimana</surname> <given-names>D.</given-names></name> <name><surname>Kim</surname> <given-names>E. K.</given-names></name></person-group> (<year>2017</year>). <article-title>Measurement methods for physical activity and energy expenditure: a review</article-title>. <source>Clin. Nutr. Res.</source> <volume>6</volume>, <fpage>68</fpage>&#x02013;<lpage>80</lpage>. <pub-id pub-id-type="doi">10.7762/cnr.2017.6.2.68</pub-id><pub-id pub-id-type="pmid">28503503</pub-id></citation></ref>
<ref id="B36">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Papazoglou</surname> <given-names>D.</given-names></name> <name><surname>Augello</surname> <given-names>G.</given-names></name> <name><surname>Tagliaferri</surname> <given-names>M.</given-names></name> <name><surname>Savia</surname> <given-names>G.</given-names></name> <name><surname>Marzullo</surname> <given-names>P.</given-names></name> <name><surname>Maltezos</surname> <given-names>E.</given-names></name> <etal/></person-group>. (<year>2006</year>). <article-title>Evaluation of a multisensor armband in estimating energy expenditure in obese individuals</article-title>. <source>Obesity</source> <volume>14</volume>, <fpage>2217</fpage>&#x02013;<lpage>2223</lpage>. <pub-id pub-id-type="doi">10.1038/oby.2006.260</pub-id><pub-id pub-id-type="pmid">17189549</pub-id></citation></ref>
<ref id="B37">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Patel</surname> <given-names>S. A.</given-names></name> <name><surname>Benzo</surname> <given-names>R. P.</given-names></name> <name><surname>Slivka</surname> <given-names>W. A.</given-names></name> <name><surname>Sciurba</surname> <given-names>F. C.</given-names></name></person-group> (<year>2007</year>). <article-title>Activity monitoring and energy expenditure in COPD patients: a validation study</article-title>. <source>COPD</source> <volume>4</volume>, <fpage>107</fpage>&#x02013;<lpage>112</lpage>. <pub-id pub-id-type="doi">10.1080/15412550701246658</pub-id><pub-id pub-id-type="pmid">17530503</pub-id></citation></ref>
<ref id="B38">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Reeve</surname> <given-names>M. D.</given-names></name> <name><surname>Pumpa</surname> <given-names>K. L.</given-names></name> <name><surname>Ball</surname> <given-names>N.</given-names></name></person-group> (<year>2014</year>). <article-title>Accuracy of the sensewear armband mini and the bodymedia fit in resistance training</article-title>. <source>J. Sci. Med. Sport</source> <volume>17</volume>, <fpage>630</fpage>&#x02013;<lpage>634</lpage>. <pub-id pub-id-type="doi">10.1016/j.jsams.2013.08.007</pub-id><pub-id pub-id-type="pmid">24120404</pub-id></citation></ref>
<ref id="B39">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Riou</surname> <given-names>M. &#x000C8;.</given-names></name> <name><surname>Rioux</surname> <given-names>F.</given-names></name> <name><surname>Lamothe</surname> <given-names>G.</given-names></name> <name><surname>Doucet</surname> <given-names>&#x000C9;.</given-names></name></person-group> (<year>2015</year>). <article-title>Validation and reliability of a classification method to measure the time spent performing different activities</article-title>. <source>PLoS ONE</source> <volume>10</volume>:<fpage>e0128299</fpage>. <pub-id pub-id-type="doi">10.1371/journal.pone.0128299</pub-id><pub-id pub-id-type="pmid">26052699</pub-id></citation></ref>
<ref id="B40">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sj&#x000F6;din</surname> <given-names>A. M.</given-names></name> <name><surname>Andersson</surname> <given-names>A. B.</given-names></name> <name><surname>H&#x000F6;gberg</surname> <given-names>J. M.</given-names></name> <name><surname>Westerterp</surname> <given-names>K. R.</given-names></name></person-group> (<year>1994</year>). <article-title>Energy balance in cross-country skiers: a study using doubly labeled water</article-title>. <source>Med. Sci. Sports Exerc.</source> <volume>26</volume>, <fpage>720</fpage>&#x02013;<lpage>724</lpage>. <pub-id pub-id-type="doi">10.1249/00005768-199406000-00011</pub-id><pub-id pub-id-type="pmid">8052113</pub-id></citation></ref>
<ref id="B41">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>St-Onge</surname> <given-names>M.</given-names></name> <name><surname>Mignault</surname> <given-names>D.</given-names></name> <name><surname>Allison</surname> <given-names>D. B.</given-names></name> <name><surname>Rabasa-Lhoret</surname> <given-names>R.</given-names></name></person-group> (<year>2007</year>). <article-title>Evaluation of a portable device to measure daily energy expenditure in free-living adults</article-title>. <source>Am. J. Clin. Nutr.</source> <volume>85</volume>, <fpage>742</fpage>&#x02013;<lpage>749</lpage>. <pub-id pub-id-type="pmid">17344495</pub-id></citation></ref>
<ref id="B42">
<citation citation-type="thesis"><person-group person-group-type="author"><name><surname>Taylor</surname> <given-names>M.</given-names></name></person-group> (<year>2012</year>). <source>Validation of the BodyMedia Mini Armband to Estimate Energy Expenditure of Female Basketball Players during Variable Intensity Game-Like Conditions</source>. Ph.D., <publisher-name>University of Pittsburgh</publisher-name>.</citation></ref>
<ref id="B43">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Trappe</surname> <given-names>T. A.</given-names></name> <name><surname>Gastaldelli</surname> <given-names>A.</given-names></name> <name><surname>Jozsi</surname> <given-names>A. C.</given-names></name> <name><surname>Troup</surname> <given-names>J. P.</given-names></name> <name><surname>Wolfe</surname> <given-names>R. R.</given-names></name></person-group> (<year>1997</year>). <article-title>Energy expenditure of swimmers during high volume training</article-title>. <source>Med. Sci. Sports Exerc.</source> <volume>29</volume>, <fpage>950</fpage>&#x02013;<lpage>954</lpage>. <pub-id pub-id-type="doi">10.1097/00005768-199707000-00015</pub-id><pub-id pub-id-type="pmid">9243495</pub-id></citation></ref>
<ref id="B44">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Vanheest</surname> <given-names>J. L.</given-names></name> <name><surname>Rodgers</surname> <given-names>C. D.</given-names></name> <name><surname>Mahoney</surname> <given-names>C. E.</given-names></name> <name><surname>De Souza</surname> <given-names>M. J.</given-names></name></person-group> (<year>2013</year>). <article-title>Ovarian suppression impairs sport performance in junior elite female swimmers</article-title>. <source>Med. Sci. Sports Exerc.</source> <volume>46</volume>, <fpage>156</fpage>&#x02013;<lpage>166</lpage>. <pub-id pub-id-type="doi">10.1249/MSS.0b013e3182a32b72</pub-id><pub-id pub-id-type="pmid">23846160</pub-id></citation></ref>
<ref id="B45">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Van Hoye</surname> <given-names>K.</given-names></name> <name><surname>Boen</surname> <given-names>F.</given-names></name> <name><surname>Lefevre</surname> <given-names>J.</given-names></name></person-group> (<year>2015</year>). <article-title>Validation of the sensewear armband in different ambient temperatures</article-title>. <source>J. Sports Sci.</source> <volume>33</volume>, <fpage>1007</fpage>&#x02013;<lpage>1018</lpage>. <pub-id pub-id-type="doi">10.1080/02640414.2014.981846</pub-id><pub-id pub-id-type="pmid">25537112</pub-id></citation></ref>
<ref id="B46">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>van Hoye</surname> <given-names>K.</given-names></name> <name><surname>Mortelmans</surname> <given-names>P.</given-names></name> <name><surname>Lefevre</surname> <given-names>J.</given-names></name></person-group> (<year>2014</year>). <article-title>Validation of the sensewear pro3 armband using an incremental exercise test</article-title>. <source>J. Strength Cond. Res.</source> <volume>28</volume>, <fpage>2806</fpage>&#x02013;<lpage>2814</lpage>. <pub-id pub-id-type="doi">10.1519/JSC.0b013e3182a1f836</pub-id><pub-id pub-id-type="pmid">25250859</pub-id></citation></ref>
<ref id="B47">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Vernillo</surname> <given-names>G.</given-names></name> <name><surname>Savoldelli</surname> <given-names>A.</given-names></name> <name><surname>Pellegrini</surname> <given-names>B.</given-names></name> <name><surname>Schena</surname> <given-names>F.</given-names></name></person-group> (<year>2015</year>). <article-title>Validity of the sensewear armband to assess energy expenditure in graded walking</article-title>. <source>J. Phys. Act. Health</source> <volume>12</volume>, <fpage>178</fpage>&#x02013;<lpage>183</lpage>. <pub-id pub-id-type="doi">10.1123/jpah.2013-0437</pub-id><pub-id pub-id-type="pmid">24508986</pub-id></citation></ref>
<ref id="B48">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Walker</surname> <given-names>E. J.</given-names></name> <name><surname>McAinch</surname> <given-names>A. J.</given-names></name> <name><surname>Sweeting</surname> <given-names>A.</given-names></name> <name><surname>Aughey</surname> <given-names>R. J.</given-names></name></person-group> (<year>2016</year>). <article-title>Inertial sensors to estimate the energy expenditure of team-sport athletes</article-title>. <source>J. Sci. Med. Sport</source> <volume>19</volume>, <fpage>177</fpage>&#x02013;<lpage>181</lpage>. <pub-id pub-id-type="doi">10.1016/j.jsams.2015.01.013</pub-id><pub-id pub-id-type="pmid">25804422</pub-id></citation></ref>
<ref id="B49">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Welk</surname> <given-names>G. J.</given-names></name> <name><surname>McClain</surname> <given-names>J. J.</given-names></name> <name><surname>Eisenmann</surname> <given-names>J. C.</given-names></name> <name><surname>Wickel</surname> <given-names>E. E.</given-names></name></person-group> (<year>2007</year>). <article-title>Field validation of the MTI actigraph and bodymedia armband monitor using the IDEEA monitor</article-title>. <source>Obesity</source> <volume>15</volume>, <fpage>918</fpage>&#x02013;<lpage>928</lpage>. <pub-id pub-id-type="doi">10.1038/oby.2007.624</pub-id><pub-id pub-id-type="pmid">17426327</pub-id></citation></ref>
<ref id="B50">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Welk</surname> <given-names>G.</given-names></name> <name><surname>Kim</surname> <given-names>Y.</given-names></name> <name><surname>Shook</surname> <given-names>R. P.</given-names></name> <name><surname>Ellingson</surname> <given-names>L.</given-names></name> <name><surname>Lobelo</surname> <given-names>R. L.</given-names></name></person-group> (<year>2017</year>). <article-title>Validation of a noninvasive, disposable activity monitor for clinical applications</article-title>. <source>J. Phys. Act. Health</source> <volume>14</volume>, <fpage>546</fpage>&#x02013;<lpage>551</lpage>. <pub-id pub-id-type="doi">10.1123/jpah.2016-0003</pub-id><pub-id pub-id-type="pmid">28290750</pub-id></citation></ref>
<ref id="B51">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Westerterp</surname> <given-names>K. R.</given-names></name></person-group> (<year>2001</year>). <article-title>Limits to sustainable human metabolic rate</article-title>. <source>J. Exp. Biol.</source> <volume>204</volume>(<issue>Pt 18</issue>), <fpage>3183</fpage>&#x02013;<lpage>3187</lpage>. <pub-id pub-id-type="pmid">11581332</pub-id></citation></ref>
<ref id="B52">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Westerterp</surname> <given-names>K. R.</given-names></name></person-group> (<year>2013</year>). <article-title>Physical activity and physical activity induced energy expenditure in humans: measurement, determinants, and effects</article-title>. <source>Front. Physiol.</source> <volume>4</volume>:<fpage>90</fpage>. <pub-id pub-id-type="doi">10.3389/fphys.2013.00090</pub-id><pub-id pub-id-type="pmid">23637685</pub-id></citation></ref>
<ref id="B53">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Westerterp</surname> <given-names>K. R.</given-names></name> <name><surname>Saris</surname> <given-names>W. H.</given-names></name> <name><surname>van Es</surname> <given-names>M.</given-names></name> <name><surname>ten Hoor</surname> <given-names>F.</given-names></name></person-group> (<year>1986</year>). <article-title>Use of the doubly labeled water technique in humans during heavy sustained exercise</article-title>. <source>J. Appl. Physiol.</source> <volume>61</volume>, <fpage>2162</fpage>&#x02013;<lpage>2167</lpage>. <pub-id pub-id-type="pmid">3027022</pub-id></citation></ref>
<ref id="B54">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Woodruff</surname> <given-names>S. J.</given-names></name> <name><surname>Meloche</surname> <given-names>R. D.</given-names></name></person-group> (<year>2013</year>). <article-title>Energy availability of female varsity volleyball players</article-title>. <source>Int. J. Sport Nutr. Exerc. Metab.</source> <volume>23</volume>, <fpage>24</fpage>&#x02013;<lpage>30</lpage>. <pub-id pub-id-type="doi">10.1123/ijsnem.23.1.24</pub-id><pub-id pub-id-type="pmid">22899818</pub-id></citation></ref>
<ref id="B55">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zanetti</surname> <given-names>S.</given-names></name> <name><surname>Pumpa</surname> <given-names>K. L.</given-names></name> <name><surname>Wheeler</surname> <given-names>K. W.</given-names></name> <name><surname>Pyne</surname> <given-names>D. B.</given-names></name></person-group> (<year>2014</year>). <article-title>Validity of the sensewear armband to assess energy expenditure during intermittent exercise and recovery in rugby union players</article-title>. <source>J. Strength Cond. Res.</source> <volume>28</volume>, <fpage>1090</fpage>&#x02013;<lpage>1095</lpage>. <pub-id pub-id-type="doi">10.1519/JSC.0000000000000243</pub-id><pub-id pub-id-type="pmid">24088866</pub-id></citation></ref>
</ref-list>
</back>
</article>