<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="research-article" dtd-version="2.3" xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Phys.</journal-id>
<journal-title>Frontiers in Physics</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Phys.</abbrev-journal-title>
<issn pub-type="epub">2296-424X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">1126753</article-id>
<article-id pub-id-type="doi">10.3389/fphy.2023.1126753</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Physics</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Flexible CsPbCl<sub>3</sub> inorganic perovskite thin-film detectors for real-time monitoring in protontherapy</article-title>
<alt-title alt-title-type="left-running-head">Bruzzi et al.</alt-title>
<alt-title alt-title-type="right-running-head">
<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3389/fphy.2023.1126753">10.3389/fphy.2023.1126753</ext-link>
</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Bruzzi</surname>
<given-names>M.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1131925/overview"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Calisi</surname>
<given-names>N.</given-names>
</name>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
<xref ref-type="aff" rid="aff4">
<sup>4</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Enea</surname>
<given-names>N.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Verroi</surname>
<given-names>E.</given-names>
</name>
<xref ref-type="aff" rid="aff5">
<sup>5</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Vinattieri</surname>
<given-names>A.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
<xref ref-type="aff" rid="aff6">
<sup>6</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1869029/overview"/>
</contrib>
</contrib-group>
<aff id="aff1">
<sup>1</sup>
<institution>Dipartimento di Fisica e Astronomia</institution>, <institution>Universit&#xe0; degli Studi di Firenze</institution>, <addr-line>Sesto Fiorentino</addr-line>, <country>Italy</country>
</aff>
<aff id="aff2">
<sup>2</sup>
<institution>INFN (National Institute of Nuclear Physics)</institution>, <institution>Florence Section</institution>, <addr-line>Florence</addr-line>, <country>Italy</country>
</aff>
<aff id="aff3">
<sup>3</sup>
<institution>INSTM (National Interuniversity Consortium of Materials Science and Technology (INSTM)</institution>, <institution>Florence research unit</institution>, <addr-line>Florence</addr-line>, <country>Italy</country>
</aff>
<aff id="aff4">
<sup>4</sup>
<institution>Dipartimento di Ingegneria Industriale</institution>, <institution>Universit&#x00E1; degli Studi di Firenze</institution>, <addr-line>Firenze</addr-line>, <country>Italy</country>
</aff>
<aff id="aff5">
<sup>5</sup>
<institution>TIFPA</institution>, <addr-line>Trento</addr-line>, <country>Italy</country>
</aff>
<aff id="aff6">
<sup>6</sup>
<institution>LENS</institution>, <addr-line>Sesto Fiorentino</addr-line>, <country>Italy</country>
</aff>
<author-notes>
<fn fn-type="edited-by">
<p>
<bold>Edited by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/659205/overview">Ge Yang</ext-link>, North Carolina State University, United States</p>
</fn>
<fn fn-type="edited-by">
<p>
<bold>Reviewed by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/2151129/overview">Petro Fochuk</ext-link>, Chernivtsi University, Ukraine</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1990398/overview">Bibhudutta Rout</ext-link>, University of North Texas, United States</p>
</fn>
<corresp id="c001">&#x2a;Correspondence: M. Bruzzi, <email>mara.bruzzi@unifi.it</email>
</corresp>
<fn fn-type="other">
<p>This article was submitted to Radiation Detectors and Imaging, a section of the journal Frontiers in Physics</p>
</fn>
</author-notes>
<pub-date pub-type="epub">
<day>02</day>
<month>02</month>
<year>2023</year>
</pub-date>
<pub-date pub-type="collection">
<year>2023</year>
</pub-date>
<volume>11</volume>
<elocation-id>1126753</elocation-id>
<history>
<date date-type="received">
<day>18</day>
<month>12</month>
<year>2022</year>
</date>
<date date-type="accepted">
<day>17</day>
<month>01</month>
<year>2023</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2023 Bruzzi, Calisi, Enea, Verroi and Vinattieri.</copyright-statement>
<copyright-year>2023</copyright-year>
<copyright-holder>Bruzzi, Calisi, Enea, Verroi and Vinattieri</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<p>
<bold>Introduction:</bold> This paper deals with the class of versatile semiconducting materials called perovskites, which have been deposited for the first time on flexible substrates and then tested for radiation detection monitoring applications.</p>
<p>
<bold>Methods:</bold> Lead halide inorganic perovskite, CsPbCl<sub>3</sub>, 0.4&#x2013;1&#xa0;&#x3bc;m-thick films have been grown on plastic flexible substrates equipped with interdigitated electrodes (IDEs) by magnetron sputtering at room temperature.</p>
<p>
<bold>Results:</bold> First measurements in realtime configuration are reported for a 1&#x2013;&#x00B5;m thick prototype under proton beams with energy in the range 100&#x2013;228&#xa0;MeV and 1&#x2013;10&#xa0;nA extraction currents, of interest for protontherapy applications.</p>
<p>
<bold>Discussion:</bold> Experimental results evidence good performances of our sample as a real-time monitoring device. Current stability under UV and proton beam exposure has been tested in the range 0.1&#x2013;120&#xa0;s, as well as reproducibility under multiple exposures. The measured current signal proved to be linearly dependent on the extraction currents at a given proton energy. Linearity of the current signal of the device with proton fluxes was also proved within two order of magnitude range, about 10<sup>7</sup>&#x2013;10<sup>9</sup>&#xa0;p/s. These promising results, when coupled with easyness of fabrication, low processing costs and high versatility of electrode configurations, all features characterizing the manufacturing process, put into evidence lead halide perovskites as promising candidates for real-time radiation detection in protontherapy.</p>
</abstract>
<kwd-group>
<kwd>lead halide perovskite</kwd>
<kwd>CsPbCl<sub>3</sub>
</kwd>
<kwd>detectors</kwd>
<kwd>dosimeters</kwd>
<kwd>proton therapy</kwd>
<kwd>RF magnetron sputtering</kwd>
</kwd-group>
</article-meta>
</front>
<body>
<sec id="s1">
<title>1 Introduction</title>
<p>Novel design strategies in radiation detection technology are recently moving towards thin, high-sensitivity and flexible solid-state devices especially characterized by low manufacturing costs and easy-processing. In this respect, the class of new and versatile semiconducting materials called perovskites is progressively experiencing an ever increasing scientific focus worldwide [<xref ref-type="bibr" rid="B1">1</xref>]. Perovskites include any material with the same type of crystal structure, ABX<sub>3</sub>, with A, B cations and X anion. In particular, metal-halide perovskites, mainly cesium lead halide (CsPbX<sub>3</sub>) and methylammonium lead halide (CH<sub>3</sub>NH<sub>3</sub>PbX<sub>3</sub>) attracted recently huge attention due to their improved optical and electrical properties. Unique physical properties of halide perovskites range from high-absorption coefficients, long-range ambipolar charge transport, high exciton-binding energy, high dielectric constant, all very attractive optoelectronic characteristics [<xref ref-type="bibr" rid="B2">2</xref>]. Growth from low-cost processes allows to manufacture them both as layered thin films, deposited on almost any kind of substrates and as single crystals of tailored size. Due to their strong stopping power, defect-tolerance, large mobility-lifetime product, high sensitivity per unit volume, halide perovskites were recently tested in several areas where stringent photodetection and dosimetric requirements are needed, as e.g. for medical imaging [<xref ref-type="bibr" rid="B3">3</xref>] radiation detectors [<xref ref-type="bibr" rid="B4">4</xref>, <xref ref-type="bibr" rid="B5">5</xref>] and dosimeter [<xref ref-type="bibr" rid="B6">6</xref>&#x2013;<xref ref-type="bibr" rid="B8">8</xref>]. Moreover, by opportunely varying the stoichiometry of the anion, starting from CsPbI<sub>3</sub> towards CsPbBr<sub>3</sub> and finally CsPbCl<sub>3</sub>, it is possible to finely tune the material bandgap from about 1&#xa0;eV to 3&#xa0;eV [<xref ref-type="bibr" rid="B9">9</xref>]. This feature provides access to a variety of different applications in photodetection and dosimetry. In particular, high-bandgap energy is an interesting feature for semiconductors in devices subject to harsh radiation environments, as the radiation induced lattice damage has no influence on the dark current of the detector [<xref ref-type="bibr" rid="B10">10</xref>].</p>
<p>This paper focuses on active devices used as real-time dosimeters for proton therapy. Their principle of operation is based on the continuous read-out, during irradiation, of the current, <italic>I</italic>, flowing between two electrodes supplied with a constant bias [<xref ref-type="bibr" rid="B11">11</xref>]. For a proper operation the current signal should be linearly dependent on the proton fluxes. To provide real-time beam monitoring <italic>in-vivo</italic>, the device should be operated in transmission during the dose delivery. In this condition, the thickness of the device should be minimized. To avoid a detrimental reduction of the sensitivity of the device, the active material should be characterized by a high sensitivity per unit volume. Recent results on inorganic halide perovskite detectors made of CsPbBr<sub>3</sub> and CsPbCl<sub>3</sub> [<xref ref-type="bibr" rid="B5">5</xref>, <xref ref-type="bibr" rid="B7">7</xref>] evidenced sensitivity per unit volume for these materials of the same order or even higher than that of silicon, diamond and silicon carbide [<xref ref-type="bibr" rid="B11">11</xref>, <xref ref-type="bibr" rid="B12">12</xref>], among the most semiconductors used for radiation detection purposes. With respect to CsPbBr<sub>3</sub>, CsPbCl<sub>3</sub> seems to be characterized by a current response as a function of time during exposure to radiation less prone to instabilities due to defects or polarization effects [<xref ref-type="bibr" rid="B13">13</xref>&#x2013;<xref ref-type="bibr" rid="B15">15</xref>]. Moreover, its high bandgap (3.0&#xa0;eV) should provide less dark current making it an intrinsically radiation harder material, as in the case of SiC [<xref ref-type="bibr" rid="B16">16</xref>]. Moreover, there is an increasing interest in the scientific community for a flexible film dosimeter that can be attached to the irregular surfaces of a patient for <italic>in vivo</italic> dosimetry during radiotherapy [<xref ref-type="bibr" rid="B17">17</xref>]. In this respect, lead halide perovksite appear attractive, as they may be grown directly on any kind surfaces by low temperature magnetron sputtering techniques.</p>
<p>This paper shows first measurements carried out with CsPbCl<sub>3</sub> thin film devices deposited on flexible substrates carrying interdigitated electrodes (IDE) when exposed to proton beams with energy in the range 100&#x2013;228&#xa0;MeV and extraction currents in the range 1&#x2013;10&#xa0;nA, of interest for proton therapy applications.</p>
</sec>
<sec sec-type="materials|methods" id="s2">
<title>2 Materials and methods</title>
<p>Cesium lead chloride (CsPbCl<sub>3</sub>) films have been grown by Radio Frequency (RF) magnetron sputtering on plastic substrates equipped with an array of Cu electrodes using a Korvus HEX (Korvus Technology Ltd.) sputter equipped with an RF source working at 13.56&#xa0;MHz [<xref ref-type="bibr" rid="B18">18</xref>&#x2013;<xref ref-type="bibr" rid="B20">20</xref>]. The precursor salts (CsCl and PbCl<sub>2</sub>) are grinded in equal molar ratio in a mixer mill (Retsch model MM400) to produce the powder used to manufacture the sputtering target: a 5&#xa0;cm diameter disk realized by pressing the perovskite powder by means of a pneumatic press (11.5&#xa0;MPa working pressure) for 24&#xa0;h at 150&#xb0;C [<xref ref-type="bibr" rid="B21">21</xref>]. The deposition is carried out at room temperature with 20&#xa0;W RF power and with a 20 sccm argon gas flow. Dynamic working pressure is 2 &#xd7; 10<sup>&#x2212;6</sup>&#xa0;atm, deposition rates are in the range 5&#x2013;7 &#xd7; 10<sup>&#x2212;2</sup>&#xa0;nm/s. The sample is nominally undoped even if unwanted p-doping is due to Cs vacancies [<xref ref-type="bibr" rid="B22">22</xref>]. The film thickness is monitored during growth by means of a quartz crystal microbalance. During deposition the sample holder rotates to ensure thickness homogeneity across the substrate.</p>
<p>A detailed electro-optical characterization of CsPbCl<sub>3</sub> thin films, deposited with the same technique on glass, has been reported elsewhere [<xref ref-type="bibr" rid="B13">13</xref>, <xref ref-type="bibr" rid="B20">20</xref>]. Room temperature transmittance spectrum provided a value of the bandgap of 3.0&#xa0;eV. Room temperature XRD spectra indicate the presence of the correct crystalline phases CsPbCl<sub>3</sub> (ICDD PDF-4&#x2b; 18-0366), orthorhombic and tetragonal crystalline phases [<xref ref-type="bibr" rid="B13">13</xref>]. SEM analyses reported in [<xref ref-type="bibr" rid="B20">20</xref>] evidences a film morphology characterized by a continuous network of several tens of nanometer size crystals with a random distribution of bigger crystals with typical micrometer/sub-micrometer size. I-V characteristics performed with samples of different thickness on glass substrates, from 100&#xa0;nm to 1.5&#xa0;&#x3bc;m indicate a good homogeneity of the semiconductor material independently of the deposition time [<xref ref-type="bibr" rid="B21">21</xref>]. Thermally stimulated currents after exposure with a 365&#xa0;nm LED priming measured from room temperature up to 370&#xa0;K showed no evidence of trapping effects due to intragap states on the electrical transport properties at room temperature of the films. As a consequence, measured photocurrents at room temperature appear to be stable in time with negligible priming effects.</p>
<p>With the purpose of prototyping first flexible thin film real-time detectors based on inorganic perovskite, we have deposited with the same technique a set of CsPbCl<sub>3</sub> films on PET substrates equipped with interdigitated electrodes (IDEs). <xref ref-type="fig" rid="F1">Figure 1A</xref> shows the sample, named &#x23;7, tested in this study under proton beam, carrying a CsPbCl<sub>3</sub> film 1&#xa0;&#x3bc;m-thick deposited on the whole interdigitated electrode array of a flexible plastic substrate (PW-IDEPD100 by DropSens). The two interdigitated electrodes have 100&#xa0;&#xb5;m bands/gaps pitches and 5 &#xd7; 7&#xa0;mm<sup>2</sup> total area and nominal 175&#xa0;&#x3bc;m thickness. The prototype is especially designed to get high electric signals starting from rather low thickness of material on a decentralized assay in planar electrode configurations. In the whole, the device is equipped with 35 pairs of contacts, 5&#xa0;mm-long each: active area is 5.0 &#xd7; 3.5&#xa0;mm<sup>2</sup>. To perform electrical measurements, the two connection tracks of the IDEs are directly connected to coaxial cables <italic>via</italic> sliding contacts. A pristine IDE substrate, &#x23;14, without the CsPbCl<sub>3</sub> thin film deposition, has been also prepared in same conditions, to be used as a reference during proton beam tests. The electrode termination are connected to Keithley 6517A/B high resistance source/electrometers, used both to supply an external voltage and to read-out the current<bold>,</bold> typically in the range 100nA-0.1&#xa0;pA. The internal circuit of the instrument allows to monitor the current in real-time with varying integration times in the range 3&#x2013;100&#xa0;ms depending on the specifically investigated current ranges.</p>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption>
<p>
<bold>(A)</bold> 1&#xa0;&#x3bc;m-thick CsPbCl<sub>3</sub> thin film deposited by magnetron sputtering on the plastic substrate equipped with Pd interdigitated electrodes (IDEs). Same device: <bold>(B)</bold> with insulating envelop to avoid for ionized air contribution, bending under tiny deformation stress; <bold>(C)</bold> inserted in the cylindric hole of a PMMA phantom slab and <bold>(D)</bold> placed at the beam isocenter of the TIFPA experimental line.</p>
</caption>
<graphic xlink:href="fphy-11-1126753-g001.tif"/>
</fig>
<p>The response of the two devices during irradiation has been tested at the proton therapy center in Trento, Italy, which is part of the Trentino Healthcare Agency (Azienda Provinciale per i Servizi Sanitari&#x2014;APSS, Italy). A cyclotron (IBA, <italic>Proteus</italic> 235) serves two medical treatment rooms both equipped with rotating gantries. Our test has been carried out at the experimental area, whose activity is managed and supervised by Trento Institute for Fundamental Physics and Applications (TIFPA) of the National Institute for Nuclear Physics (INFN). The total energy range of the proton therapy facility is 70&#x2013;228&#xa0;MeV, typical treatments fluxes are in the range 10<sup>6</sup>&#x2013;10<sup>9</sup>&#xa0;p/s [<xref ref-type="bibr" rid="B23">23</xref>].</p>
<p>After a preliminary optical and electrical characterization of the devices, we have measured in real-time configuration the current response of our devices to proton beams with energy in the range 100&#x2013;228&#xa0;MeV and extraction currents in the range 1&#x2013;10&#xa0;nA. During tests under the proton beam, the prototypes, including its electrode terminations, has been sealed into an insulating envelope to avoid unwanted current contributions due to the ionized air close to electrodes. Our configuration still allows for sample flexibility. Picture in <xref ref-type="fig" rid="F1">Figure 1B</xref> shows the sample under test, &#x23;7 within its insulating envelope, bending under a tiny mechanical stress. The devices have been encapsulated in a 10 &#xd7; 10&#xa0;cm<sup>2</sup> PolyMethylMethAcrylate (PMMA) slab 1&#xa0;cm thick (see <xref ref-type="fig" rid="F1">Figure 1C</xref>) within a cylindric hole of the same diameter of the sliding contacts connector (1.3&#xa0;cm), ensuring sample flexibility. The PMMA phantom has been placed at the isocenter of the beam at the TIFPA experimental line (see <xref ref-type="fig" rid="F1">Figure 1D</xref>). During the proton test beam the flexible sample has been always kept in planar configuration.</p>
<p>The proton flux per unit extraction current (1&#xa0;nA) impinging on the detector area is plotted as a function of the proton beam energy in <xref ref-type="fig" rid="F2">Figure 2</xref>, together with an exponential best-fit to data shown as a guide-line. The fraction of protons reaching the detector has been estimated by integrating the beam profile, essentially Gaussian, on the detector area:<disp-formula id="e1">
<mml:math id="m1">
<mml:mrow>
<mml:mi>f</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mn>1</mml:mn>
<mml:mrow>
<mml:mn>2</mml:mn>
<mml:mi>&#x3c0;</mml:mi>
<mml:mi>&#x3c3;</mml:mi>
<mml:msup>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="|">
<mml:mrow>
<mml:mi>E</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msup>
</mml:mrow>
</mml:mfrac>
<mml:msubsup>
<mml:mo>&#x222b;</mml:mo>
<mml:mrow>
<mml:mo>&#x2212;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mi>a</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
<mml:mrow>
<mml:mfrac>
<mml:mrow>
<mml:mi>a</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:msubsup>
<mml:msubsup>
<mml:mo>&#x222b;</mml:mo>
<mml:mrow>
<mml:mo>&#x2212;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mi>b</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
<mml:mrow>
<mml:mfrac>
<mml:mrow>
<mml:mi>b</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:msubsup>
<mml:mo>&#x2061;</mml:mo>
<mml:mi>exp</mml:mi>
<mml:mrow>
<mml:mfenced open="[" close="]" separators="|">
<mml:mrow>
<mml:mo>&#x2212;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:msup>
<mml:mi>x</mml:mi>
<mml:mn>2</mml:mn>
</mml:msup>
<mml:mo>&#x2b;</mml:mo>
<mml:msup>
<mml:mi>y</mml:mi>
<mml:mn>2</mml:mn>
</mml:msup>
</mml:mrow>
<mml:mrow>
<mml:mn>2</mml:mn>
<mml:mtext>&#x2009;</mml:mtext>
<mml:msup>
<mml:mrow>
<mml:mi>&#x3c3;</mml:mi>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="|">
<mml:mrow>
<mml:mi>E</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msup>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mi>d</mml:mi>
<mml:mi>x</mml:mi>
<mml:mtext>&#x2009;</mml:mtext>
<mml:mi>d</mml:mi>
<mml:mi>y</mml:mi>
<mml:mo>,</mml:mo>
</mml:mrow>
</mml:math>
<label>(1)</label>
</disp-formula>where a and b are the lateral dimensions of the detector and <inline-formula id="inf1">
<mml:math id="m2">
<mml:mrow>
<mml:mi>&#x3c3;</mml:mi>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="|">
<mml:mrow>
<mml:mi>E</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula> is the spatial standard deviation (i.e. the width) of the beam Gaussian profile for that particular energy E [<xref ref-type="bibr" rid="B23">23</xref>]. The maximum positioning error of the sample with the precision alignment laser system can lead to an error of 5% in the case of narrowest beam.</p>
<fig id="F2" position="float">
<label>FIGURE 2</label>
<caption>
<p>Proton flux incident on the detector area per unit extraction current (1&#xa0;nA) plotted as a function of the proton beam energy. Exponential best-fits is shown only for guide-line purposes.</p>
</caption>
<graphic xlink:href="fphy-11-1126753-g002.tif"/>
</fig>
</sec>
<sec id="s3">
<title>3 Experimental results</title>
<sec id="s3-1">
<title>3.1 Optical and electrical characterization</title>
<p>Preliminary optical and electrical characterization of the films deposited on the flexible interdigitated electrodes have been performed at room temperature (T &#x3d; 21&#xb0;C). Photoluminescence (PL) experiments have been performed after excitation with a 266&#xa0;nm laser with an excitation power of 10&#xa0;mW: the PL has been dispersed by a spectrograph (Kymera 193i Andor Corp.) and detected by a CCD camera (IDUS 401 Andor Corp). PL spectra for a set of five samples with different thicknesses are shown in <xref ref-type="fig" rid="F3">Figures 3A, B</xref>. The indication of treated sample means a thermal annealing at 150&#xb0;C for 20&#xa0;h. The plots evidence no major differences depending on the film thickness and thermal treatment in the PL intensity and lineshape. Results are in agreement with those found with similar samples grown on glass substrates [<xref ref-type="bibr" rid="B13">13</xref>].</p>
<fig id="F3" position="float">
<label>FIGURE 3</label>
<caption>
<p>Photoluminescence spectra (PL) spectra for the different samples: in <bold>(A)</bold> the intensity is shown in log scale, in <bold>(B)</bold> normalized spectra are reported for a comparison of the lineshape.</p>
</caption>
<graphic xlink:href="fphy-11-1126753-g003.tif"/>
</fig>
<p>Current Voltage (IV) characterization of our devices in dark have been also performed. In particular, <xref ref-type="fig" rid="F4">Figure 4A</xref> shows the dark current of the 1&#xa0;&#x3bc;m-thick CsPbCl<sub>3</sub> film deposited on the Pd IDEs as a function of time, measured along a 2&#xa0;min interval with different applied voltages. The plot evidences the stability in time of the measured current. <xref ref-type="fig" rid="F4">Figure 4B</xref> shows the average current measured as a function of the voltage at 21&#xb0;C in the range 1&#x2013;5&#xa0;V. The measurements have been carried with the device in planar configuration. Further I-V measurements done after bending the sample for 1&#xa0;min with a curvature radius of 7&#xa0;mm along the longer size of the device showed changes in the I-V characteristics within 2%. The ohmic behavior of the device is evidenced by the linear best-fit to data; the resistance calculated from the slope of the curve is about 7 &#xd7; 10<sup>9</sup>&#xa0;&#x3a9;. Taking into consideration geometry and thickness of the device, from these data we get a room temperature resistivity &#x3c1; &#x3d; 1.2 &#xd7; 10<sup>7</sup>&#xa0;&#x3a9;&#xa0;m, in good agreement with Ref. [<xref ref-type="bibr" rid="B13">13</xref>].</p>
<fig id="F4" position="float">
<label>FIGURE 4</label>
<caption>
<p>
<bold>(A)</bold> Dark current of the 1&#xa0;&#x3bc;m-thick CsPbCl<sub>3</sub> film deposited on Pd IDEs as a function of time measured at room temperature and different applied voltages. <bold>(B)</bold> Average currents plotted as a function of the voltage, with linear best fit.</p>
</caption>
<graphic xlink:href="fphy-11-1126753-g004.tif"/>
</fig>
<p>
<xref ref-type="fig" rid="F5">Figure 5</xref> shows the response of the same device to a train of square pulses from a 365&#xa0;nm UV lamp with frequency of 1&#xa0;Hz and intensity 100&#xa0;W/m<sup>2</sup> at different applied voltages (10-5-2&#xa0;V), for an interval of 30&#xa0;s at sampling times of 100&#xa0;ms. The plot shows a stable and repeatible photoconductive transient response, with rise and decay times in the range of 0.1&#xa0;s or less on the entire time interval and amplitude linerly increasing with the applied voltage.</p>
<fig id="F5" position="float">
<label>FIGURE 5</label>
<caption>
<p>Current signal of the 1&#xa0;&#x3bc;m-thick CsPbCl<sub>3</sub> film deposited on the Pd IDEs due to the excitation of a train of square pulses from a 365&#xa0;nm UV LED lamp with frequency of 1&#xa0;Hz and intensity 100&#xa0;W/m<sup>2</sup>. Measurements are carried out at different applied voltages and sampling time windows of 100&#xa0;ms.</p>
</caption>
<graphic xlink:href="fphy-11-1126753-g005.tif"/>
</fig>
</sec>
<sec id="s3-2">
<title>3.2 Detector response in real-time configuration under proton beams</title>
<p>After this preliminary characterization we have measured the current response of the same prototype, &#x23;7, under proton beams of different energy and extraction current operation. <xref ref-type="fig" rid="F6">Figure 6</xref> shows the current measured with the same prototype, &#x23;7, under exposure to a 220&#xa0;MeV proton beam and extraction currents values progressively decreasing: 10-5-2-1&#xa0;nA. To evidence a possible contribution to the signal due to the interdigitated electrodes and PET substrate, the same measurement has been performed using a device with same packaging, electrodes and substrate but no perovskite film deposited on it (&#x23;14). The current response of device &#x23;14 in exactly the same conditions as &#x23;7 is shown in the same plot of <xref ref-type="fig" rid="F6">Figure 6</xref>. From the plot we observe that a current signal is collected also by the interdigitated electrode substrate without the perovskite film, probably due to the polarization of the plastic substrate. Anyway, this signal is definitely lower than those measured in the same conditions by device &#x23;7, carrying the CsPbCl<sub>3</sub> 1&#xa0;&#x3bc;m-thick film. In fact, by comparing results of the &#x23;7 and &#x23;14 devices, we get that the perovskite thin film current contribution is about 3.5 times that due to the substrate. Moreover, we observe that instabilities in the current response, as the slow rise-time observed when the beam is switched on, especially at highest extraction currents (10&#xa0;nA), and current oscillations during measurements, are not due to the perovskite film itself, but should rather to be considered as instrumental effects due to the coupling of the read-out electronics of the high-impedance multimeter and the IDE/Pd substrate.</p>
<fig id="F6" position="float">
<label>FIGURE 6</label>
<caption>
<p>Current response of the sample prototype &#x23;7, carrying the 1&#xa0;&#x3bc;m-thick CsPbCl<sub>3</sub> film on the IDE/Pd substrate measured and of prototype &#x23;14, without the CsPbCl<sub>3</sub> film on the same substrate, plotted as a function of time under exposure to a 220&#xa0;MeV proton beam using different extraction currents: 10-5-2-1&#xa0;nA (dark current subtracted, applied voltage V &#x3d; 2&#xa0;V).</p>
</caption>
<graphic xlink:href="fphy-11-1126753-g006.tif"/>
</fig>
<p>After these evidences, further measurements we have been focused on the current response of the prototype carrying the CsPbCl<sub>3</sub> film. <xref ref-type="fig" rid="F7">Figure 7</xref> shows the average signals measured by the device as a function of the extraction current respectively for 220MeV and 198&#xa0;MeV. The current signal is obtained by subtracting the dark current to the measured current. Best-fits to data, also shown, give evidence of the linear dependence of the signal on the extraction currents for each proton energies.</p>
<fig id="F7" position="float">
<label>FIGURE 7</label>
<caption>
<p>Average signals measured by the &#x23;7 (1&#xa0;&#x3bc;m-thick CsPbCl<sub>3</sub> on IDE/Pd) prototype as a function of the extraction current respectively under exposure of three different proton beam energies, applied voltage &#x3d; 2&#xa0;V.</p>
</caption>
<graphic xlink:href="fphy-11-1126753-g007.tif"/>
</fig>
<p>
<xref ref-type="fig" rid="F8">Figure 8</xref> shows the current signal (dark current subtracted) of the same prototype, &#x23;7, measured at same extraction current, 10&#xa0;nA, and four different proton beam energies, 198-211-220 and 228&#xa0;MeV, same exposure time interval, &#x394;t &#x3d; 110&#xa0;s and same applied voltage across electrodes (2&#xa0;V).</p>
<fig id="F8" position="float">
<label>FIGURE 8</label>
<caption>
<p>Current signals measured by the &#x23;7 prototype 1&#xa0;&#x3bc;m-thick CsPbCl<sub>3</sub> on IDE/Pd substrate, as a function of time for different proton beam energies and same extraction current, 10&#xa0;nA. Applied voltage across electrodes is V &#x3d; 2&#xa0;V.</p>
</caption>
<graphic xlink:href="fphy-11-1126753-g008.tif"/>
</fig>
<p>
<xref ref-type="fig" rid="F9">Figure 9</xref> shows the average current signals measured in this experiment plotted as a function of the proton fluxes calculated at each proton energy for 10&#xa0;nA extraction currents. Values of the corresponding effective proton fluxes are obtained considering the plot given in <xref ref-type="fig" rid="F2">Figure 2</xref> and multipling by the extraction current. Best-fit to data indicates a linear dependence of the current of our device on the proton flux.</p>
<fig id="F9" position="float">
<label>FIGURE 9</label>
<caption>
<p>Average current measured by the 1&#xa0;&#x3bc;m-thick CsPbCl<sub>3</sub> IDE/Pd prototype &#x23;7 (applied voltage V &#x3d; 2&#xa0;V) as a function of the proton fluxes corresponding to the beam energies 198-211-220&#x2013;228&#xa0;MeV and same extraction current (10&#xa0;nA), polynomial fit added as a guide-line.</p>
</caption>
<graphic xlink:href="fphy-11-1126753-g009.tif"/>
</fig>
<p>Finally, <xref ref-type="fig" rid="F10">Figure 10</xref> shows in a log-log plot the average current signal (dark current subtracted) measured during a set of 20 different measurements carried out with different proton energies and extraction currents, varied respectively in the ranges 100&#x2013;228&#xa0;MeV and 1&#x2013;10&#xa0;nA. Values of the corresponding effective proton fluxes impinging on the detector area have been obtained by Eq. <xref ref-type="disp-formula" rid="e1">1</xref> (see <xref ref-type="fig" rid="F2">Figure 2</xref>) and multipling by the corresponding extraction currents. The best fit to data evidence a linear trend on almost a two-order magnitude scale for proton fluxes in the range 4x10<sup>7</sup> to 2 &#xd7; 10<sup>9</sup>&#xa0;p/s.</p>
<fig id="F10" position="float">
<label>FIGURE 10</label>
<caption>
<p>Average current measured by the 1&#xa0;&#x3bc;m-thick CsPbCl<sub>3</sub> IDE/Pd prototype, &#x23;7 (applied voltage V &#x3d; 2&#xa0;V) as a function of the proton flux impinging on the detector area, measred at different energies and extraction currents, respectively in the ranges 100&#x2013;228&#xa0;MeV and 1&#x2013;10&#xa0;nA. Best-fit to data shows a linear trend.</p>
</caption>
<graphic xlink:href="fphy-11-1126753-g010.tif"/>
</fig>
</sec>
</sec>
<sec sec-type="conclusion" id="s4">
<title>4 Conclusion</title>
<p>This paper shows first lead halide CsPbCl<sub>3</sub> thin film deposition on flexible PET substrates carrying interdigitated electrodes (IDE) for sensor developments. The CsPbCl<sub>3</sub> thin films have been deposited by magnetron sputtering at room temperature by means of a one-step process on IDEs made with Pd on plastic substrates (CsPbCl<sub>3</sub>/Pd IDE). First measurements of these prototype sensors in real-time configuration are reported under test beam with proton energy in the range 100&#x2013;228&#xa0;MeV and extraction currents in the range 1&#x2013;10&#xa0;nA, of interest for proton therapy applications. Experimental results evidence the good performances of the CsPbCl<sub>3</sub>/Pd IDE in terms of real-time monitoring, linearity with current extraction and proton fluxes in almost two orders of magnitude range, 4x10<sup>7</sup>&#x2014;2 &#xd7; 10<sup>9</sup>&#xa0;p/s. These promising results, when coupled with easyness of fabrication, low processing costs and high versatility of electrode configurations, all features characterizing our manufacturing process, put into evidence lead halide perovskite, CsPbCl<sub>3</sub>, as a promising candidate for future radiation monitoring in protontherapy.</p>
</sec>
</body>
<back>
<sec sec-type="data-availability" id="s5">
<title>Data availability statement</title>
<p>The original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding author.</p>
</sec>
<sec id="s6">
<title>Author contributions</title>
<p>Conceptualization, MB and AV; methodology, MB, AV, and EV; software, MB and EV; device manufacturing MB, and NC; validation, MB, AV, and EV; formal analysis, MB, EV, and AV; investigation, MB, EV, NE, and AV; resources, MB; data curation, MB and EV; writing&#x2014;original draft preparation, MB; writing&#x2014;review and editing, MB, AV, and EV; supervision, MB and AV; project administration, MB; funding acquisition, MB.</p>
</sec>
<sec id="s7">
<title>Funding</title>
<p>Work performed in the framework of the experiment ANEMONE financed by Istituto Nazionale di Fisica Nucleare, CSN5-INFN, Italy.</p>
</sec>
<sec sec-type="COI-statement" id="s8">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec sec-type="disclaimer" id="s9">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ref-list>
<title>References</title>
<ref id="B1">
<label>1.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Brenner</surname>
<given-names>TM</given-names>
</name>
<name>
<surname>Egger</surname>
<given-names>DA</given-names>
</name>
<name>
<surname>Kronik</surname>
<given-names>L</given-names>
</name>
<name>
<surname>Hodes</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Cahen</surname>
<given-names>D</given-names>
</name>
</person-group>. <article-title>Hybrid organic-inorganic perovskites: Low-cost semiconductors with intriguing charge-transport properties</article-title>. <source>Nat Rev Mater</source> (<year>2016</year>) <volume>1</volume>:<fpage>15007</fpage>. <pub-id pub-id-type="doi">10.1038/natrevmats.2015.7</pub-id>
</citation>
</ref>
<ref id="B2">
<label>2.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kovalenko</surname>
<given-names>MV</given-names>
</name>
<name>
<surname>Protesescu</surname>
<given-names>L</given-names>
</name>
<name>
<surname>Bodnarchuk</surname>
<given-names>MI</given-names>
</name>
</person-group>. <article-title>Properties and potential optoelectronic applications of lead halide perovskite nanocrystals</article-title>. <source>Science</source> (<year>2017</year>) <volume>358</volume>:<fpage>745</fpage>&#x2013;<lpage>50</lpage>. <pub-id pub-id-type="doi">10.1126/science.aam7093</pub-id>
</citation>
</ref>
<ref id="B3">
<label>3.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhou</surname>
<given-names>Y</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Bakr</surname>
<given-names>OM</given-names>
</name>
<name>
<surname>Mohammed</surname>
<given-names>OF</given-names>
</name>
</person-group>. <article-title>Metal halide perovskites for X-ray imaging scintillators and detectors</article-title>. <source>ACS Energ Lett</source> (<year>2021</year>) <volume>6</volume>:<fpage>739</fpage>&#x2013;<lpage>68</lpage>. <pub-id pub-id-type="doi">10.1021/acsenergylett.0c02430</pub-id>
</citation>
</ref>
<ref id="B4">
<label>4.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wei</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Huang</surname>
<given-names>J</given-names>
</name>
</person-group>. <article-title>Halide lead perovskites for ionizing radiation detection</article-title>. <source>Nat Commun</source> (<year>2019</year>) <volume>10</volume>:<fpage>1066</fpage>. <pub-id pub-id-type="doi">10.1038/s41467-019-08981-w</pub-id>
</citation>
</ref>
<ref id="B5">
<label>5.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>He</surname>
<given-names>Y</given-names>
</name>
<name>
<surname>Stoumpos</surname>
<given-names>CC</given-names>
</name>
<name>
<surname>Hadar</surname>
<given-names>I</given-names>
</name>
<name>
<surname>Luo</surname>
<given-names>Z</given-names>
</name>
<name>
<surname>McCall</surname>
<given-names>KM</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>Z</given-names>
</name>
<etal/>
</person-group> <article-title>Demonstration of energy-resolved &#x3b3;-ray detection at room temperature by the CsPbCl<sub>3</sub> perovskite semiconductor</article-title>. <source>J Am Chem Soc</source> (<year>2021</year>) <volume>143</volume>(<issue>4</issue>):<fpage>2068</fpage>&#x2013;<lpage>77</lpage>. <pub-id pub-id-type="doi">10.1021/jacs.0c12254</pub-id>
</citation>
</ref>
<ref id="B6">
<label>6.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bruzzi</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Talamonti</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Calisi</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Falsini</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Vinattieri</surname>
<given-names>A</given-names>
</name>
</person-group>. <article-title>First proof-of-principle of inorganic perovskites clinical radiotherapy dosimeters</article-title>. <source>Phys Lett Mater</source> (<year>2019</year>) <volume>7</volume>:<fpage>051101</fpage>. <pub-id pub-id-type="doi">10.1063/1.5083810</pub-id>
</citation>
</ref>
<ref id="B7">
<label>7.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bruzzi</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Calisi</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Latino</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Falsini</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Anna</surname>
<given-names>V</given-names>
</name>
<name>
<surname>Talamonti</surname>
<given-names>C</given-names>
</name>
</person-group>. <article-title>Magnetron sputtered CsPbCl3 perovskite detectors as real-time dosimeters for clinical radiotherapy</article-title>. <source>Z f&#xfc;r Medizinische Physik</source> (<year>2022</year>) <volume>32</volume>:<fpage>392</fpage>&#x2013;<lpage>402</lpage>. <pub-id pub-id-type="doi">10.1016/j.zemedi.2022.02.003</pub-id>
</citation>
</ref>
<ref id="B8">
<label>8.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bruzzi</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Talamonti</surname>
<given-names>C</given-names>
</name>
</person-group>. <article-title>Characterization of crystalline CsPbBr<sub>3</sub> perovskite dosimeters for clinical radiotherapy</article-title>. <source>Front Phys</source> (<year>2021</year>) <volume>9</volume>:<fpage>625282</fpage>. <pub-id pub-id-type="doi">10.3389/fphy.2021.625282</pub-id>
</citation>
</ref>
<ref id="B9">
<label>9.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ghaithan</surname>
<given-names>HM</given-names>
</name>
<name>
<surname>Alahmed</surname>
<given-names>ZA</given-names>
</name>
<name>
<surname>Qaid</surname>
<given-names>SMH</given-names>
</name>
<name>
<surname>Aldwayyan</surname>
<given-names>AS</given-names>
</name>
</person-group>. <article-title>Density functional theory analysis of structural, electronic, and optical properties of mixed-halide orthorhombic inorganic perovskites</article-title>. <source>Inorg Perovskites</source> (<year>2021</year>) <volume>6</volume>(<issue>45</issue>):<fpage>30752</fpage>&#x2013;<lpage>61</lpage>. <pub-id pub-id-type="doi">10.1021/acsomega.1c04806</pub-id>
</citation>
</ref>
<ref id="B10">
<label>10.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bruzzi</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Sadrozinski</surname>
<given-names>HF-W</given-names>
</name>
<name>
<surname>Seiden</surname>
<given-names>A</given-names>
</name>
</person-group>. <article-title>Comparing radiation tolerant materials and devices for ultra rad-hard tracking detectors</article-title>. <source>Nucl Instr Meth Phys Res A</source> (<year>2007</year>) <volume>579</volume>(<issue>2</issue>):<fpage>754</fpage>&#x2013;<lpage>61</lpage>. <pub-id pub-id-type="doi">10.1016/j.nima.2007.05.326</pub-id>
</citation>
</ref>
<ref id="B11">
<label>11.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bruzzi</surname>
<given-names>M</given-names>
</name>
</person-group>. <article-title>Novel silicon devices for radiation therapy monitoring</article-title>. <source>Nucl Instr Meth Phys Res A</source> (<year>2016</year>) <volume>809</volume>:<fpage>105</fpage>&#x2013;<lpage>12</lpage>. <pub-id pub-id-type="doi">10.1016/j.nima.2015.10.072</pub-id>
</citation>
</ref>
<ref id="B12">
<label>12.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Owens</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Peacock</surname>
<given-names>A</given-names>
</name>
</person-group>. <article-title>Compound semiconductor radiation detectors</article-title>. <source>Nucl Instr Meth Phys Res A</source> (<year>2004</year>) <volume>531</volume>:<fpage>18</fpage>&#x2013;<lpage>37</lpage>. <pub-id pub-id-type="doi">10.1016/j.nima.2004.05.071</pub-id>
</citation>
</ref>
<ref id="B13">
<label>13.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bruzzi</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Latino</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Falsini</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Calisi</surname>
<given-names>N</given-names>
</name>
</person-group>. <article-title>A Vinattieri electrical and optical characterization of CsPbCl<sub>3</sub> films around the high-temperature phase transitions</article-title>. <source>Nanomaterials</source> (<year>2022</year>) <volume>12</volume>(<issue>3</issue>):<fpage>570</fpage>&#x2013;<lpage>2022</lpage>. <pub-id pub-id-type="doi">10.3390/nano12030570</pub-id>
</citation>
</ref>
<ref id="B14">
<label>14.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bruzzi</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Gabelloni</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Calisi</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Caporali</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Vinattieri</surname>
<given-names>A</given-names>
</name>
</person-group>. <article-title>Defective states in micro-crystalline CsPbBr<sub>3</sub> and their role on photoconductivity</article-title>. <source>Nanomaterials</source> (<year>2019</year>) <volume>9</volume>(<issue>2</issue>):<fpage>177</fpage>. <pub-id pub-id-type="doi">10.3390/nano9020177</pub-id>
</citation>
</ref>
<ref id="B15">
<label>15.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bruzzi</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Calisi</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Falsini</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Vinattieri</surname>
<given-names>A</given-names>
</name>
</person-group>. <article-title>Electrically active defects in polycrystalline and single crystal metal halide perovskite</article-title>. <source>Energies</source> (<year>2020</year>) <volume>13</volume>(<issue>7</issue>):<fpage>1643</fpage>. <pub-id pub-id-type="doi">10.3390/en13071643</pub-id>
</citation>
</ref>
<ref id="B16">
<label>16.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bruzzi</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Nava</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Russo</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Sciortino</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Vanni</surname>
<given-names>P</given-names>
</name>
</person-group>. <article-title>Characterisation of silicon carbide detectors response to electron and photon irradiation</article-title>. <source>Diamond Relat Mater</source> (<year>2001</year>) <volume>10</volume>:<fpage>657</fpage>&#x2013;<lpage>61</lpage>. <pub-id pub-id-type="doi">10.1016/s0925-9635(00)00380-0</pub-id>
</citation>
</ref>
<ref id="B17">
<label>17.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cho</surname>
<given-names>JD</given-names>
</name>
<name>
<surname>Son</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Sung</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Choi</surname>
<given-names>CH</given-names>
</name>
<name>
<surname>Kim</surname>
<given-names>JS</given-names>
</name>
<name>
<surname>Wu</surname>
<given-names>H-G</given-names>
</name>
<etal/>
</person-group> <article-title>Flexible film dosimeter for <italic>in vivo</italic> dosimetry</article-title>. <source>Med Phys</source> (<year>2020</year>) <volume>47</volume>(<issue>7</issue>):<fpage>3204</fpage>&#x2013;<lpage>13</lpage>. <pub-id pub-id-type="doi">10.1002/mp.14162</pub-id>
</citation>
</ref>
<ref id="B18">
<label>18.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Seth</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Samanta</surname>
<given-names>A</given-names>
</name>
</person-group>. <article-title>A facile methodology for engineering the morphology of CsPbX<sub>3</sub> perovskite nanocrystals under ambient condition</article-title>. <source>Sci Rep</source> (<year>2016</year>) <volume>6</volume>:<fpage>37693</fpage>. <pub-id pub-id-type="doi">10.1038/srep37693</pub-id>
</citation>
</ref>
<ref id="B19">
<label>19.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Borri</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Calisi</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Galvanetto</surname>
<given-names>E</given-names>
</name>
<name>
<surname>Falsini</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Biccari</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Vinattieri</surname>
<given-names>A</given-names>
</name>
<etal/>
</person-group> <article-title>First proof-of-principle of inorganic lead halide perovskites deposition by magnetron-sputtering</article-title>. <source>Nanomaterials</source> (<year>2019</year>) <volume>10</volume>:<fpage>60</fpage>. <pub-id pub-id-type="doi">10.3390/nano10010060</pub-id>
</citation>
</ref>
<ref id="B20">
<label>20.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Falsini</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Calisi</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Roini</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Ristori</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Biccari</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Scardi</surname>
<given-names>P</given-names>
</name>
<etal/>
</person-group> <article-title>A new route for caesium lead halide perovskite deposition</article-title>. <source>Nanomaterials</source> (<year>2021</year>) <volume>11</volume>:<fpage>8</fpage>. <pub-id pub-id-type="doi">10.1186/s41476-021-00153-y</pub-id>
</citation>
</ref>
<ref id="B21">
<label>21.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Falsini</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Ristori</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Biccari</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Calisi</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Roini</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Scardi</surname>
<given-names>P</given-names>
</name>
<etal/>
</person-group> <article-title>A new route for high quality nanometric films of inorganic halide perovskites</article-title>. <source>J Eur Opt Soc.-Rapid Publ</source> (<year>2021</year>) <volume>17</volume>:<fpage>07004</fpage>. <pub-id pub-id-type="doi">10.1051/epjconf/202023807004</pub-id>
</citation>
</ref>
<ref id="B22">
<label>22.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wu</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Pi</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Zhou</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>Q</given-names>
</name>
<name>
<surname>Long</surname>
<given-names>Z</given-names>
</name>
<name>
<surname>Qiu</surname>
<given-names>J</given-names>
</name>
</person-group>. <article-title>Effect of cation vacancy on lattice and luminescence properties in CsPbBr<sub>3</sub> quantum dots</article-title>. <source>Ceramics Int</source> (<year>2022</year>) <volume>48</volume>:<fpage>3383</fpage>&#x2013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1016/j.ceramint.2021.10.114</pub-id>
</citation>
</ref>
<ref id="B23">
<label>23.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tommasino</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Rovituso</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Fabiano</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Piffer</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Manea</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Lorentini</surname>
<given-names>S</given-names>
</name>
<etal/>
</person-group> <article-title>Proton beam characterization in the experimental room of the Trento Proton Therapy facility</article-title>. <source>Nucl Inst Meth Phys Res A</source> (<year>2017</year>) <volume>869</volume>:<fpage>15</fpage>&#x2013;<lpage>20</lpage>. <pub-id pub-id-type="doi">10.1016/j.nima.2017.06.017</pub-id>
</citation>
</ref>
</ref-list>
</back>
</article>