<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="research-article" dtd-version="2.3" xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Phys.</journal-id>
<journal-title>Frontiers in Physics</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Phys.</abbrev-journal-title>
<issn pub-type="epub">2296-424X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">1071063</article-id>
<article-id pub-id-type="doi">10.3389/fphy.2022.1071063</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Physics</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Numerical study of defect localization in additive manufactured short fiber reinforced composites with diffuse ultrasonic wave inspection</article-title>
<alt-title alt-title-type="left-running-head">Peng et al.</alt-title>
<alt-title alt-title-type="right-running-head">
<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3389/fphy.2022.1071063">10.3389/fphy.2022.1071063</ext-link>
</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Peng</surname>
<given-names>Yue</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/2049311/overview"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Xu</surname>
<given-names>Hongxuan</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Sun</surname>
<given-names>Jingguo</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Zuo</surname>
<given-names>Jiancun</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Zhu</surname>
<given-names>Qi</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1902870/overview"/>
</contrib>
</contrib-group>
<aff id="aff1">
<sup>1</sup>
<institution>School of Computer and Information</institution>, <institution>Shanghai Polytechnic University</institution>, <addr-line>Shanghai</addr-line>, <country>China</country>
</aff>
<aff id="aff2">
<sup>2</sup>
<institution>School of Mechatronic Engineering and Automation</institution>, <institution>Shanghai University</institution>, <addr-line>Shanghai</addr-line>, <country>China</country>
</aff>
<author-notes>
<fn fn-type="edited-by">
<p>
<bold>Edited by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1850633/overview">Jianbo Wu</ext-link>, Sichuan University, China</p>
</fn>
<fn fn-type="edited-by">
<p>
<bold>Reviewed by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/2056538/overview">Jiang Xu</ext-link>, Huazhong University of Science and Technology, China</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1844786/overview">Bo Feng</ext-link>, Huazhong University of Science and Technology, China</p>
</fn>
<corresp id="c001">&#x2a;Correspondence: Qi Zhu, <email>Q_ZHU@shu.edu.cn</email>
</corresp>
<fn fn-type="other">
<p>This article was submitted to Physical Acoustics and Ultrasonics, a section of the journal Frontiers in Physics</p>
</fn>
</author-notes>
<pub-date pub-type="epub">
<day>17</day>
<month>11</month>
<year>2022</year>
</pub-date>
<pub-date pub-type="collection">
<year>2022</year>
</pub-date>
<volume>10</volume>
<elocation-id>1071063</elocation-id>
<history>
<date date-type="received">
<day>15</day>
<month>10</month>
<year>2022</year>
</date>
<date date-type="accepted">
<day>03</day>
<month>11</month>
<year>2022</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2022 Peng, Xu, Sun, Zuo and Zhu.</copyright-statement>
<copyright-year>2022</copyright-year>
<copyright-holder>Peng, Xu, Sun, Zuo and Zhu</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<p>The structures of short fiber reinforced composites become designable from macroscopic to microscopic due to the advancement in additive manufacturing technologies. The diffuse ultrasonic wave inspection benefits from information from multiple scattering processes, which is suitable for the quality assurance of complex structures. This study established a two-dimensional wave propagation model assuming the decoupling of the fiber volume into the fiber distribution matrix in the plane and the local fiber fraction along the thickness axis. The k-space pseudospectral method was applied to calculate the diffuse wave fields. The defect inspection process was studied numerically based on the Locadiff technique for additive-manufactured short-fiber reinforced composites. The stretching method provided the same average distance but a smaller relative deviation to the defect than the doublet method. The localization resolution improved significantly for the initial increment of the number of transmitters; limited improvement can be achieved further. Localization results fluctuated when the transmitter combination groups were distant from the defect. This method worked well with the isotropic and quasi-isotropic plates, while an oversimplification was found for the unidirectional fiber structure.</p>
</abstract>
<kwd-group>
<kwd>diffuse ultrasonic wave</kwd>
<kwd>defect localization</kwd>
<kwd>short fiber reinforced composite</kwd>
<kwd>additive manufacturing</kwd>
<kwd>structural health monitoring</kwd>
</kwd-group>
<contract-num rid="cn001">EGD21QD23 and EGD22DS08</contract-num>
<contract-num rid="cn002">pilab2209</contract-num>
<contract-sponsor id="cn001">Shanghai Polytechnic University<named-content content-type="fundref-id">10.13039/501100015604</named-content>
</contract-sponsor>
<contract-sponsor id="cn002">Shanghai University<named-content content-type="fundref-id">10.13039/501100009002</named-content>
</contract-sponsor>
</article-meta>
</front>
<body>
<sec id="s1">
<title>1 Introduction</title>
<p>Composite structures are widely used in the aviation, machinery, and other domains owing to their high specific strength, specific modulus, and other advantages. Efficient and rapid operation and maintenance (O&#x26;M) of composite based mechanical structures is crucial for ensuring high levels of performance and reliability of mechanical equipment. Current health monitoring methods for composite structures include vibration mode monitoring [<xref ref-type="bibr" rid="B1">1</xref>], structural strain monitoring [<xref ref-type="bibr" rid="B2">2</xref>,<xref ref-type="bibr" rid="B3">3</xref>,<xref ref-type="bibr" rid="B4">4</xref>], acoustic emission technology [<xref ref-type="bibr" rid="B5">5</xref>]; [<xref ref-type="bibr" rid="B6">6</xref>], and intelligent coating technology [<xref ref-type="bibr" rid="B7">7</xref>]. Among them, the ultrasonic structural health monitoring method, which often distributes piezoelectric sensors [<xref ref-type="bibr" rid="B8">8</xref>] inside a structure, is economical and easy to implement. However, the existing centralized and distributed general mechanical equipment structure health monitoring systems are wired-state monitoring systems. An online monitoring system based on a wireless sensor network (WSN) [<xref ref-type="bibr" rid="B9">9</xref>] can reduce wiring and lower deployment cost; furthermore, it offers increased flexibility, maintainability, and scalability. Therefore, the application of WSN technology to mechanical equipment online monitoring systems is highly desired. WSNs have been used in a few applications for structural health monitoring. However, many challenges, such as short lifetimes, unreliable communication, and poor real-time performance, should be resolved. Therefore, research on efficient and accurate real-time monitoring methods is crucial for structural health monitoring.</p>
<p>Various ultrasonic techniques can improve imaging quality and efficiency. Thick welded joints can be inspected using laser ultrasound B-scans based on the synthetic aperture focusing technique (SAFT) [<xref ref-type="bibr" rid="B10">10</xref>]. Phased array [<xref ref-type="bibr" rid="B11">11</xref>] inspection using multiple transmitter-receiver pairs can facilitate full matrix capture (FMC) and full-field imaging with the total focusing method (TFM) to increase inspection efficiency. Wavenumber algorithm [<xref ref-type="bibr" rid="B12">12</xref>] is considered to further accelerate the imaging speed in real-time based on the wave equation for the defect inside composites.</p>
<p>Additionally, classical beamforming methods, such as multiple signal classification (MUSIC), can be used to decompose the covariance matrix of an array output data into eigenvalue to obtain the signal subspace corresponding to the signal component and the noise subspace orthogonal to the signal component, which can be used to effectively denoise and extract the characteristic signal [<xref ref-type="bibr" rid="B13">13</xref>]. The main features of this signal can be extracted to locate the signal source. Yuan et al. proposed that the near-field two-dimensional (2D)-MUSIC method [<xref ref-type="bibr" rid="B14">14</xref>] can simultaneously locate the damage angle and distance in composite structures. Furthermore, Yang et al. proposed the Am MUSIC damage-imaging method [<xref ref-type="bibr" rid="B15">15</xref>]. The complete spatial spectrum of a test sample can be generated by quantizing the orthogonal attribute between the inherent signal and noise subspaces of a matrix, and the process is not limited by the number of damages. Bao et al. proposed an anisotropic compensation MUSIC algorithm [<xref ref-type="bibr" rid="B16">16</xref>] that can jointly compensate for different types of sensor phase errors to reduce the positioning error. This algorithm was verified through a reinforced composite plate structure to improve the accuracy and reliability of damage positioning. Xu et al. proposed a focused MUSIC algorithm [<xref ref-type="bibr" rid="B17">17</xref>] for baseline-free Lamb-wave-based damage location in isotropic materials. The virtual time-reversal technique was used to compensate for the dispersion effect, and the focused signal was truncated to avoid estimating the number of scattering sources and baseline subtraction. Fan et al. used phase-coherent MUSIC [<xref ref-type="bibr" rid="B18">18</xref>] for EDM line inspection, which could evaluate its length even when it was oblique to the linear array.</p>
<p>These methods facilitate the localization and imaging of regional damages. However, scattering occurs when applied to complex configurations, such as walls, ribs, corners, and beams in a structure and it interferes with acoustic wave transmission. In this study, we performed inversion imaging of internal defects in various composite structures using multi-channel scattering information to achieve wireless autonomous recognition in combination with WSNs.</p>
</sec>
<sec id="s2">
<title>2 Theory</title>
<sec id="s2-1">
<title>2.1 Forward model</title>
<p>A diffuse wave field can be established after multiple scattering in a complex medium like additive manufacted composites. The defect information can be amplified in the help of this field. Suppose the waveforms <inline-formula id="inf1">
<mml:math id="m1">
<mml:msub>
<mml:mrow>
<mml:mi>&#x3c6;</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi>A</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>R</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:math>
</inline-formula> and <inline-formula id="inf2">
<mml:math id="m2">
<mml:msub>
<mml:mrow>
<mml:mi>&#x3c6;</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi>B</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>R</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:math>
</inline-formula> received at position R can be obtained before and after a defect appearance under an impulse excitation source at position S. The correlation between these two can then be calculated through <xref ref-type="disp-formula" rid="e1">Eq. 1</xref> ([<xref ref-type="bibr" rid="B19">19</xref>,<xref ref-type="bibr" rid="B20">20</xref>]):<disp-formula id="e1">
<mml:math id="m3">
<mml:mfenced open="&#x27e8;" close="&#x27e9;">
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mi>&#x3c6;</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi>A</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>R</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mfenced>
<mml:msub>
<mml:mrow>
<mml:mi>&#x3c6;</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi>B</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>R</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mfenced>
<mml:mo>&#x3d;</mml:mo>
<mml:mi>I</mml:mi>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>R</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mfenced>
<mml:mo>&#x2212;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mi>c</mml:mi>
<mml:mi>&#x3c3;</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:mfrac>
<mml:msubsup>
<mml:mrow>
<mml:mo>&#x222b;</mml:mo>
</mml:mrow>
<mml:mrow>
<mml:mn>0</mml:mn>
</mml:mrow>
<mml:mrow>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:msubsup>
<mml:mi>I</mml:mi>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>x</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>u</mml:mi>
</mml:mrow>
</mml:mfenced>
<mml:mi>I</mml:mi>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mi>x</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>R</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>t</mml:mi>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>u</mml:mi>
</mml:mrow>
</mml:mfenced>
<mml:mi>d</mml:mi>
<mml:mi>u</mml:mi>
</mml:math>
<label>(1)</label>
</disp-formula>where <italic>c</italic> denotes the wave velocity, <italic>x</italic> corresponds to the defect location, <italic>&#x3c3;</italic> represents the scattering cross-section, and <inline-formula id="inf3">
<mml:math id="m4">
<mml:mi>I</mml:mi>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mi>r</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mn>1</mml:mn>
</mml:mrow>
</mml:msub>
<mml:mo>,</mml:mo>
<mml:msub>
<mml:mrow>
<mml:mi>r</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:msub>
<mml:mo>,</mml:mo>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:math>
</inline-formula> is the intensity propagator from position <italic>r</italic>
<sub>1</sub> to <italic>r</italic>
<sub>2</sub> along time <italic>t</italic>. <xref ref-type="disp-formula" rid="e1">Eq. 1</xref> is an expression of Green&#x2019;s function recovery method without defect presentation[<xref ref-type="bibr" rid="B10">10</xref>] when <italic>&#x3c3;</italic> &#x3d; 0. It can be normalized into <xref ref-type="disp-formula" rid="e2">Eq. 2</xref>:<disp-formula id="e2">
<mml:math id="m5">
<mml:mfrac>
<mml:mrow>
<mml:mfenced open="&#x27e8;" close="&#x27e9;">
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mi>&#x3c6;</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi>A</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>R</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mfenced>
<mml:msub>
<mml:mrow>
<mml:mi>&#x3c6;</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi>B</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>R</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mrow>
<mml:msqrt>
<mml:mrow>
<mml:mfenced open="&#x27e8;" close="&#x27e9;">
<mml:mrow>
<mml:msup>
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mi>&#x3c6;</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi>A</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mrow>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:msup>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>R</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mfenced>
<mml:mfenced open="&#x27e8;" close="&#x27e9;">
<mml:mrow>
<mml:msup>
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mi>&#x3c6;</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi>B</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mrow>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:msup>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>R</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:msqrt>
</mml:mrow>
</mml:mfrac>
<mml:mo>&#x3d;</mml:mo>
<mml:mi>C</mml:mi>
<mml:mi>C</mml:mi>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>R</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>x</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mfenced>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>D</mml:mi>
<mml:mi>C</mml:mi>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>R</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>x</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:math>
<label>(2)</label>
</disp-formula>
</p>
<p>where <italic>CC</italic> represents the correlation coefficient and <italic>DC</italic> denotes the decorrelation coefficient. <italic>DC</italic> &#x3d; 0 when the two waveforms are identical and <italic>DC</italic> &#x3d; 1 when the two waveforms are absolutely different. Moreover, the decorrelation coefficient is related to the sensitivity kernel function through <xref ref-type="disp-formula" rid="e3">Eqs 3</xref>, <xref ref-type="disp-formula" rid="e4">4</xref> as follows:<disp-formula id="e3">
<mml:math id="m6">
<mml:mi>D</mml:mi>
<mml:mi>C</mml:mi>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>R</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>r</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mfenced>
<mml:mo>&#x3d;</mml:mo>
<mml:mspace width="0.3333em"/>
<mml:mfrac>
<mml:mrow>
<mml:mi>c</mml:mi>
<mml:mi>&#x3c3;</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:mfrac>
<mml:mi>K</mml:mi>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>R</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>r</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:math>
<label>(3)</label>
</disp-formula>
</p>
<p>and<disp-formula id="e4">
<mml:math id="m7">
<mml:mi>K</mml:mi>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>R</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>r</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mfenced>
<mml:mo>&#x3d;</mml:mo>
<mml:mspace width="0.3333em"/>
<mml:mfrac>
<mml:mrow>
<mml:msubsup>
<mml:mrow>
<mml:mo>&#x222b;</mml:mo>
</mml:mrow>
<mml:mrow>
<mml:mn>0</mml:mn>
</mml:mrow>
<mml:mrow>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:msubsup>
<mml:mi>I</mml:mi>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>r</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>u</mml:mi>
</mml:mrow>
</mml:mfenced>
<mml:mi>I</mml:mi>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mi>r</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>R</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>t</mml:mi>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>u</mml:mi>
</mml:mrow>
</mml:mfenced>
<mml:mi>d</mml:mi>
<mml:mi>u</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi>I</mml:mi>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>R</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mfrac>
</mml:math>
<label>(4)</label>
</disp-formula>
</p>
<p>If the composite sample has an isotropic scattering property in an infinite d-dimensional, the average scattering intensity distribution approximates to the diffusion equation solution:<disp-formula id="e5">
<mml:math id="m8">
<mml:mi>I</mml:mi>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mi>r</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mn>1</mml:mn>
</mml:mrow>
</mml:msub>
<mml:mo>,</mml:mo>
<mml:msub>
<mml:mrow>
<mml:mi>r</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:msub>
<mml:mo>,</mml:mo>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mfenced>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mn>4</mml:mn>
<mml:mi>&#x3c0;</mml:mi>
<mml:mi>D</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mrow>
<mml:mfrac>
<mml:mrow>
<mml:mi>d</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:msup>
</mml:mrow>
</mml:mfrac>
<mml:mi>e</mml:mi>
<mml:mi>x</mml:mi>
<mml:mi>p</mml:mi>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>k</mml:mi>
<mml:mi>t</mml:mi>
<mml:mo>&#x2212;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mi>r</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:msub>
<mml:mrow>
<mml:mi>r</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mn>1</mml:mn>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mrow>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:msup>
</mml:mrow>
<mml:mrow>
<mml:mn>4</mml:mn>
<mml:mi>D</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:mfenced>
</mml:math>
<label>(5)</label>
</disp-formula>
</p>
<p>where <italic>D</italic> denotes the diffusivity and k is the dissipation parameter. A more accurate solution can be obtained from the radiative transfer equation. The first born approximation can be used[<xref ref-type="bibr" rid="B21">21</xref>] to study the kernel in weak scattering media if the scattering is not sufficiently strong for the diffusion approximation. More generally, the kernel does not have an analytical form and should be calculated numerically for heterogeneous scattering.</p>
</sec>
<sec id="s2-2">
<title>2.2 Inversion model</title>
<p>After obtaining <italic>DC</italic>(<italic>S</italic>, <italic>R</italic>, <italic>x</italic>, <italic>t</italic>) and <italic>K</italic>(<italic>S</italic>, <italic>R</italic>, <italic>r</italic>, <italic>t</italic>), the defect location can be predicted from different inversion algorithms, e.g., linear least square inversion method[<xref ref-type="bibr" rid="B22">22</xref>] and Monte Carlo Markov chain method[<xref ref-type="bibr" rid="B23">23</xref>]. A classical grid search method[<xref ref-type="bibr" rid="B17">17</xref>] was used by searching for the most likely defect position through the cost function:<disp-formula id="e6">
<mml:math id="m9">
<mml:mi>e</mml:mi>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mi>x</mml:mi>
</mml:mrow>
</mml:mfenced>
<mml:mo>&#x3d;</mml:mo>
<mml:mo>&#x2211;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mi mathvariant="normal">D</mml:mi>
<mml:mi mathvariant="normal">C</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:msup>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mi>&#x3b5;</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:msup>
</mml:mrow>
</mml:mfrac>
<mml:mo>&#x2212;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mo>&#x2211;</mml:mo>
<mml:mi>D</mml:mi>
<mml:mi>C</mml:mi>
<mml:mo>&#x2022;</mml:mo>
<mml:mi>K</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mrow>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:msup>
</mml:mrow>
<mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mi>&#x3b5;</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:msup>
<mml:mo>&#x2211;</mml:mo>
<mml:msup>
<mml:mrow>
<mml:mi>K</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:msup>
</mml:mrow>
</mml:mfrac>
</mml:math>
<label>(6)</label>
</disp-formula>
</p>
<p>The probability density of the defect appearance at x is defined in <xref ref-type="disp-formula" rid="e7">Eq. 7</xref>:<disp-formula id="e7">
<mml:math id="m10">
<mml:mi>p</mml:mi>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mi>x</mml:mi>
</mml:mrow>
</mml:mfenced>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mrow>
<mml:mi>C</mml:mi>
</mml:mrow>
</mml:mfrac>
<mml:mi>e</mml:mi>
<mml:mi>x</mml:mi>
<mml:mi>p</mml:mi>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mo>&#x2212;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mi>e</mml:mi>
<mml:mfenced open="(" close=")">
<mml:mrow>
<mml:mi>x</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mn>2</mml:mn>
<mml:mi>&#x3b5;</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:msup>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:mfenced>
</mml:math>
<label>(7)</label>
</disp-formula>
</p>
<p>where <italic>&#x25b;</italic> corresponds to a fluctuation parameter for decorrelations and <italic>C</italic> denotes a normalization constant.</p>
</sec>
</sec>
<sec id="s3">
<title>3 Numerical simulations</title>
<p>The internal structure of composites can be classified into microscopic, mesoscopic, and macroscopic scale [<xref ref-type="bibr" rid="B24">24</xref>]. The homogenization method is often applied to determine the effective properties of heterogeneous media [<xref ref-type="bibr" rid="B25">25</xref>] and to simplify the wave propagation in these structures [<xref ref-type="bibr" rid="B26">26</xref>] by keeping the same strain energy between the heterogeneous and homogeneous materials under arbitrary loads. It is an efficient way to balance the computational cost and the calculation accuracy, especially for lamb wave inspection concerning phase velocity or group velocity information in hundreds of kHz [<xref ref-type="bibr" rid="B27">27</xref>]. However, diffuse ultrasonic wave inspection simulation demands mesoscopic or even microscopic details to extract diffuse ultrasonic wave fields from the wave-structure interaction. The k-space pseudospectral method [<xref ref-type="bibr" rid="B28">28</xref>] was applied for acoustic wave propagation simulation in Matlab software. The material properties of polyamide 12 and short carbon fiber are listed in <xref ref-type="table" rid="T1">Table 1</xref>. A perfect matched layer was added to eliminate the edge effect.</p>
<table-wrap id="T1" position="float">
<label>TABLE 1</label>
<caption>
<p>Material parameters.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="left">Items</th>
<th align="left">Values</th>
<th align="left">Items</th>
<th align="left">Values</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">Young&#x2019;s modulus of short fiber, <italic>E</italic>
<sub>
<italic>f</italic>
</sub>
</td>
<td align="left">200&#xa0;<italic>GPa</italic>
</td>
<td align="left">Local fiber fraction, <italic>P</italic>
<sub>
<italic>z</italic>
</sub>
</td>
<td align="left">40%</td>
</tr>
<tr>
<td align="left">Young&#x2019;s modulus of the matrix, <italic>E</italic>
<sub>
<italic>m</italic>
</sub>
</td>
<td align="left">3&#xa0;<italic>GPa</italic>
</td>
<td align="left">Effective Young&#x2019;s modulus, <italic>E</italic>
<sub>
<italic>eff</italic>
</sub> &#x3d; <italic>E</italic>
<sub>
<italic>f</italic>
</sub> &#x22c5; <italic>P</italic>
<sub>
<italic>z</italic>
</sub> &#x2b; <italic>E</italic>
<sub>
<italic>m</italic>
</sub> (1 &#x2212; <italic>P</italic>
<sub>
<italic>z</italic>
</sub>)</td>
<td align="left">81.2&#xa0;<italic>GPa</italic>
</td>
</tr>
<tr>
<td align="left">Density of the matrix, <italic>&#x3c1;</italic>
<sub>
<italic>m</italic>
</sub>
</td>
<td align="left">1,150&#xa0;kg/<italic>m</italic>
<sup>3</sup>
</td>
<td align="left">Effective density, <italic>&#x3c1;</italic>
<sub>
<italic>eff</italic>
</sub> &#x3d; <italic>&#x3c1;</italic>
<sub>
<italic>f</italic>
</sub> &#x22c5; <italic>P</italic>
<sub>
<italic>z</italic>
</sub> &#x2b; <italic>&#x3c1;</italic>
<sub>
<italic>m</italic>
</sub> (1 &#x2212; <italic>P</italic>
<sub>
<italic>z</italic>
</sub>)</td>
<td align="left">1,410&#xa0;kg/<italic>m</italic>
<sup>3</sup>
</td>
</tr>
<tr>
<td align="left">Density of short fiber, <italic>&#x3c1;</italic>
<sub>
<italic>f</italic>
</sub>
</td>
<td align="left">1800&#xa0;kg/<italic>m</italic>
<sup>3</sup>
</td>
<td align="left">Frequency, <italic>f</italic>
</td>
<td align="left">2&#xa0;<italic>MHz</italic>
</td>
</tr>
<tr>
<td align="left">Acoustic velocity of short fiber, <italic>V</italic>
<sub>
<italic>f</italic>
</sub>
</td>
<td align="left">8,804.7&#xa0;m/<italic>s</italic>
</td>
<td align="left">Absorption [<xref ref-type="bibr" rid="B32">32</xref>], <italic>&#x3b1;</italic>
</td>
<td align="left">10&#xa0;<italic>db</italic>/<italic>cm</italic>
</td>
</tr>
<tr>
<td align="left">Acoustic velocity of the matrix, <italic>V</italic>
<sub>
<italic>m</italic>
</sub>
</td>
<td align="left">1874&#xa0;m/<italic>s</italic>
</td>
<td align="left">Ratio of non-zero elements in <italic>P</italic>
<sub>
<italic>surface</italic>
</sub>
</td>
<td align="left">50%</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>In order to simplify the numerical model, the fiber volume fraction <inline-formula id="inf4">
<mml:math id="m11">
<mml:msub>
<mml:mrow>
<mml:mi mathvariant="bold">P</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mi>f</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mtext>_</mml:mtext>
<mml:mi>t</mml:mi>
<mml:mi>o</mml:mi>
<mml:mi>t</mml:mi>
<mml:mi>a</mml:mi>
<mml:mi>l</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:msub>
</mml:math>
</inline-formula> was decoupled into the fiber distribution matrix <bold>P</bold>
<sub>
<italic>surface</italic>
</sub> in the x-y plane and the local fiber fraction <italic>P</italic>
<sub>
<italic>z</italic>
</sub> along <italic>Z</italic> according to <xref ref-type="disp-formula" rid="e8">Eq. 8</xref> as shown in <xref ref-type="fig" rid="F1">Figure 1</xref>. <xref ref-type="disp-formula" rid="e7">Eq. 7</xref> defines the probability density of the defect appearance at x as:<disp-formula id="e8">
<mml:math id="m12">
<mml:msub>
<mml:mrow>
<mml:mi mathvariant="bold">P</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mi>f</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mtext>_</mml:mtext>
<mml:mi>t</mml:mi>
<mml:mi>o</mml:mi>
<mml:mi>t</mml:mi>
<mml:mi>a</mml:mi>
<mml:mi>l</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mi>P</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi>z</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2022;</mml:mo>
<mml:mi mathvariant="bold">P</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi mathvariant="italic">surface</mml:mi>
</mml:mrow>
</mml:msub>
</mml:math>
<label>(8)</label>
</disp-formula>
</p>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption>
<p>Simplified model of additive manufactured short fiber composites.</p>
</caption>
<graphic xlink:href="fphy-10-1071063-g001.tif"/>
</fig>
<p>Since a higher fiber volume fraction will lead to an increasing degree of misalignment from additive manufacturing [<xref ref-type="bibr" rid="B29">29</xref>], the local fiber fraction is set to be isotropic. Meanwhile, the high specific strength plate is always thin (<italic>d</italic> &#x226a; <italic>L</italic>) that a constant local fiber fraction of <italic>P</italic>
<sub>
<italic>z</italic>
</sub> &#x3d; 40% was applied with 150 &#xd7; 150 mesh size in the x-y plane. The ratio of non-zero elements in <italic>P</italic>
<sub>
<italic>surface</italic>
</sub> is assumed to be 50%. The whole defect localization scheme can be shown in <xref ref-type="fig" rid="F2">Figure 2</xref> below.</p>
<fig id="F2" position="float">
<label>FIGURE 2</label>
<caption>
<p>Defect localization scheme.</p>
</caption>
<graphic xlink:href="fphy-10-1071063-g002.tif"/>
</fig>
<p>In order to balance between the high attenuation in polymers by keeping relative high sensitivity, the inspection frequency was chosen to be 2&#xa0;<italic>MHz</italic> here. A Gussian-shaped toneburst is chosen as the excitation source during simulation. Both its time and frequency domain wavefroms are shown in <xref ref-type="fig" rid="F3">Figure 3</xref>. The plate dimension was 0.45 &#xd7; 0.45 m<sup>2</sup> with the center of a 0.015 &#xd7; 0.015 m<sup>2</sup> rectangular defect positioned at [0.3 m, 0.15 m]. The material properties of the defect such as missing extrudates[<xref ref-type="bibr" rid="B30">30</xref>], were assumed to be 80% of those in the initial state. The pitch-catch configuration and the typical waveforms for a random short fiber reinforced composite plate from the pair 3&#x2013;11 are presented in <xref ref-type="fig" rid="F4">Figure 4</xref>. The diffusivity and the dissipation parameter can be decided from the waveform envelope through the Hilbert transform combing <xref ref-type="disp-formula" rid="e5">Equation 5</xref>, i.e., <italic>D</italic> &#x3d; 34&#xa0;<italic>m</italic>/<italic>s</italic> and <italic>k</italic> &#x3d; 4.5 &#xd7; 10<sup>3</sup>/<italic>s</italic>. The transport mean free path <italic>L</italic>&#x2a; &#x3d; 2<italic>D</italic>/<italic>c</italic> &#x2248; 2<italic>D</italic>/((<italic>V</italic>
<sub>
<italic>f</italic>
</sub> &#x2b; <italic>V</italic>
<sub>
<italic>m</italic>
</sub>)/2) &#x3d; 0.012 m was significantly less than the smallest transmitter-receiver pair distance between the pair 1-1 <italic>L</italic>
<sub>1&#x2212;1</sub> &#x3d; 0.3 m, ensuring multiple-scattered acoustic wave.</p>
<fig id="F3" position="float">
<label>FIGURE 3</label>
<caption>
<p>The excitation source in <bold>(A)</bold> time domain <bold>(B)</bold>frequency domain.</p>
</caption>
<graphic xlink:href="fphy-10-1071063-g003.tif"/>
</fig>
<fig id="F4" position="float">
<label>FIGURE 4</label>
<caption>
<p>
<bold>(A)</bold>Plate dimension and measurement scheme <bold>(B)</bold>Representative waveforms for the pair 3&#x2013;11.</p>
</caption>
<graphic xlink:href="fphy-10-1071063-g004.tif"/>
</fig>
</sec>
<sec id="s4">
<title>4 Results</title>
<sec id="s4-1">
<title>4.1 Influence of the kernel determination method</title>
<p>According to <xref ref-type="disp-formula" rid="e2">Eq. 2</xref>, the correlation or decorrelation coefficient can be determined from the waveforms with and without the defect. The doublet method (or cross-spectral moving-window method) and the stretching methods are often used for coefficient calculation. Both methods are influenced by the correlation window width (W). By applying the doublet method, the correlation coefficient of the pair 3&#x2013;11 (<xref ref-type="fig" rid="F5">Figure 5</xref>) at <italic>t</italic> &#x3d; 0.6&#xa0;<italic>m</italic> varied between 0.56 and 0.69 when W changes (<italic>W</italic> &#x3d; 30<italic>&#xa0;&#xb5;s,</italic> 60 <italic>&#x3bc;s</italic> and 90&#xa0;&#xb5;s).</p>
<fig id="F5" position="float">
<label>FIGURE 5</label>
<caption>
<p>Comparison between doublet method and stretching method for the waveforms from the pair 3 &#x2212; 11</p>
</caption>
<graphic xlink:href="fphy-10-1071063-g005.tif"/>
</fig>
<p>The localization precision would be further influenced by such variation if only the transmitter positions 1&#x2013;3 were adopted with receiver positions 1&#x2013;12 fixed. The average distance (AD) to the defect and relative deviation (RD)were 0.029 m and 8.4, respectively. Such ambiguity can be prevented by adding more transmitters (<xref ref-type="fig" rid="F6">Figure 6</xref>), i.e., <italic>AD</italic> &#x3d; 0.016 and <italic>RD</italic> &#x3d; 3.5% with all the transmitter positions. On the contrary, the stretching method gives a stable and smooth correlation coefficient between 0.64 and 0.68 at <italic>t</italic> &#x3d; 0.6&#xa0;<italic>m</italic>. As shown in <xref ref-type="fig" rid="F6">Figure 6</xref>, the corresponding AD values were nearly identical to those obtained from the doublet method. However, RD from the stretching method decreased to 2.8% with transmitter positions 1&#x2013;3 and approached zero with more transmitter positions. The stretching method with the superior coefficient calculation stability was further applied in this study.</p>
<fig id="F6" position="float">
<label>FIGURE 6</label>
<caption>
<p>The average distances using different transmitters. Error bars represent the standard deviation ranges.</p>
</caption>
<graphic xlink:href="fphy-10-1071063-g006.tif"/>
</fig>
</sec>
<sec id="s4-2">
<title>4.2 Influence of the transmitters</title>
<p>Diffuse ultrasonic waves can magnify the defects that are influenced by multiple scattering. The defect can be influenced by the diffuse field after a long time at a random position, enabling defect localization. The transmitter-receiver number and distribution optimization always remain problematic for reasonable inspection efficiency. Only the influence of transmitters was studied, keeping the receivers fixed due to the repeatability and reciprocity of the diffuse ultrasonic wave inspection [<xref ref-type="bibr" rid="B31">31</xref>]. The different combinations can be adopted for a defined number of transmitters. Increasing the number of transmitters provided a better defect localization resolution with a decreasing standard deviation, as shown in <xref ref-type="fig" rid="F7">Figure 7</xref>. The average distance converged to 0.016 m, and six random transmitters were sufficient for this plate. Limited localization precision can be improved with more transmitters added.</p>
<fig id="F7" position="float">
<label>FIGURE 7</label>
<caption>
<p>The average distance error to the defect center from different number of transmitters. Error bars represent the standard deviation ranges.</p>
</caption>
<graphic xlink:href="fphy-10-1071063-g007.tif"/>
</fig>
<p>The localization deviation not only depends on the number of transmitters, but also on the transmitter distribution. When 3 transmitters are chosen among the total 12 ones, 220 combinations can be expected with different root-mean-square-distances (<italic>RMSD</italic>) to the defect. As shown in <xref ref-type="fig" rid="F8">Figure 8A</xref>, the distance prediction error increases when the <italic>RMSD</italic>of the transmitter group increases. A consistent value can be found for the transmitter group near the defect (<italic>RMSD</italic> &#x3c; 0.2 m). There is an increasing error when the transmitter group becomes far from the defect (<italic>RMSD</italic> &#x3e; 0.2 m). When 8 transmitters are adopted with 495 combinations, a much more consistent value can be observed in <xref ref-type="fig" rid="F8">Figure 8B</xref>. However, the distance value still becomes scatter when the transmitters are far from the defect location. For a real panel, the defect locations are always unknown. Such fluctuation information can also help to verify the proper number and distribution through combination changes in experiments.</p>
<fig id="F8" position="float">
<label>FIGURE 8</label>
<caption>
<p>Distance to the defect center with different transmitter distribution <bold>(A)</bold> Number of transmitters &#x3d; 3 <bold>(B)</bold> Number of transmitters &#x3d; 8.</p>
</caption>
<graphic xlink:href="fphy-10-1071063-g008.tif"/>
</fig>
</sec>
<sec id="s4-3">
<title>4.3 Influence of the fiber structure</title>
<p>Additive manufacturing enables structure design with short fibers in composites. The mesoscopic structure can vary significantly regarding to the physical property requirement during the design stage under the same ratio of non-zero elements in the P surface. Different multiple scattering behavior during diffuse ultrasonic wave inspection should be considered.</p>
<p>Three typical additive manufactured composite plates were investigated; they are shown in <xref ref-type="fig" rid="F9">Figures 9A&#x2013;C</xref> with a random pattern, plain weave pattern, and unidirectional pattern, respectively. They have isotropic, quasi-isotropic, and anisotropic macro mechanical properties, respectively. Their corresponding scattering behaviors can be found in <xref ref-type="fig" rid="F9">Figures 9D&#x2013;F</xref>. The defect localization results can be found in <xref ref-type="fig" rid="F9">Figures 9G&#x2013;I</xref> under the full transmitter-receiver implementation with the material properties listed in <xref ref-type="table" rid="T1">Table 1</xref>. The result shows that the localized defect coordinate is at [0.294 m, 0.134&#xa0;m] for the random pattern with a small error of <inline-formula id="inf5">
<mml:math id="m13">
<mml:mn>3.8</mml:mn>
<mml:mi>%</mml:mi>
<mml:mspace width="0.3333em"/>
<mml:mrow>
<mml:mo stretchy="false">(</mml:mo>
<mml:mrow>
<mml:mfrac>
<mml:mrow>
<mml:mo stretchy="false">&#x2016;</mml:mo>
<mml:msub>
<mml:mrow>
<mml:mi>r</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi mathvariant="italic">measure</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:msub>
<mml:mrow>
<mml:mi>r</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi mathvariant="italic">real</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo stretchy="false">&#x2016;</mml:mo>
</mml:mrow>
<mml:mrow>
<mml:mi>L</mml:mi>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
<mml:mo stretchy="false">)</mml:mo>
</mml:mrow>
</mml:math>
</inline-formula>. An acceptable result can be found for the plain weave pattern with the error of 8.4% due to its quasi-isotropic nature. For unidirectional pattern, a large error of 29.7% was observed. The isotropic sensitivity kernel calculated from <xref ref-type="disp-formula" rid="e5">Eq. 5</xref> is no more compatible. Numerical intensity solution concerning anisotropic behavior should be used for the kernel computation.</p>
<fig id="F9" position="float">
<label>FIGURE 9</label>
<caption>
<p>Diffuse ultrasonic wave pattern <bold>(D)</bold>&#x2013;<bold>(F)</bold> and localization result <bold>(G)</bold>&#x2013;<bold>(I)</bold> in different additive manufactured short fiber reinforced composites <bold>(A)</bold>&#x2013;<bold>(C)</bold>.</p>
</caption>
<graphic xlink:href="fphy-10-1071063-g009.tif"/>
</fig>
</sec>
</sec>
<sec id="s5">
<title>5 Conclusion</title>
<p>Additive manufactured fiber-reinforced polymer composites can possess complex structures from macroscopic to microscopic scales, making their quality assurance difficult. The diffuse ultrasonic wave inspection relies on the multiple scattering domain that contains rich structure information. The Locadiff technique is processed based on a simplified 2D mechanical model by homogenization along the thickness direction. The stretching method was more stable than the doublet method for correlation/decorrelation coefficient calculation and enabled reliable defect localization. An increasing number of transmitters improved the localization precision. However, the localization results fluctuated from the transmitter combination groups that were distant from the defect. The numerical investigation indicated that this method works well with isotropic and quasi-isotropic composite plates with the errors of 3.8% and 8.4%respectively. Further exploration for the defect localization in additive manufactured parts concerning anisotropic scattering and signal processing is expected.</p>
</sec>
</body>
<back>
<sec sec-type="data-availability" id="s6">
<title>Data availability statement</title>
<p>The original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding author.</p>
</sec>
<sec id="s7">
<title>Author contributions</title>
<p>YP, JZ, and QZ contributed to conception and design of the study. YP organized the database and performed the formal analysis. QZ wrote the first draft of the manuscript. HX, JS, JZ, and YP wrote sections of the manuscript. All authors contributed to manuscript revision, read, and approved the submitted version.</p>
</sec>
<sec id="s8">
<title>Funding</title>
<p>This work was supported in grants from State key laboratory of precision measuring technology and instruments (Grant No: pilab2209) and Shanghai Polytechnic University (Grant No: EGD21QD23 and EGD22DS08).</p>
</sec>
<sec sec-type="COI-statement" id="s9">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec sec-type="disclaimer" id="s10">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ref-list>
<title>References</title>
<ref id="B1">
<label>1.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhang</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Mousavi</surname>
<given-names>AA</given-names>
</name>
<name>
<surname>Masri</surname>
<given-names>SF</given-names>
</name>
<name>
<surname>Gholipour</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Yan</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>X</given-names>
</name>
</person-group>. <article-title>Vibration feature extraction using signal processing techniques for structural health monitoring: A review</article-title>. <source>Mech Syst Signal Process</source> (<year>2022</year>) <volume>177</volume>:<fpage>109175</fpage>. <pub-id pub-id-type="doi">10.1016/j.ymssp.2022.109175</pub-id>
</citation>
</ref>
<ref id="B2">
<label>2.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tserpes</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Karachalios</surname>
<given-names>V</given-names>
</name>
<name>
<surname>Giannopoulos</surname>
<given-names>I</given-names>
</name>
<name>
<surname>Prentzias</surname>
<given-names>V</given-names>
</name>
<name>
<surname>Ruzek</surname>
<given-names>R</given-names>
</name>
</person-group>. <article-title>Strain and damage monitoring in cfrp fuselage panels using fiber Bragg grating sensors. part i: Design, manufacturing and impact testing</article-title>. <source>Compos Structures</source> (<year>2014</year>) <volume>107</volume>:<fpage>726</fpage>&#x2013;<lpage>36</lpage>. <pub-id pub-id-type="doi">10.1016/j.compstruct.2013.09.053</pub-id>
</citation>
</ref>
<ref id="B3">
<label>3.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bergmayr</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Winklberger</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Kralovec</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Schagerl</surname>
<given-names>M</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Strain measurements along zero-strain trajectories as possible structural health monitoring method for debonding initiation and propagation in aircraft sandwich structures</article-title>. <source>Proced Struct Integrity</source> <volume>28</volume>, <fpage>1473</fpage>&#x2013;<lpage>80</lpage>. <pub-id pub-id-type="doi">10.1016/j.prostr.2020.10.121</pub-id>
<comment>1st Virtual European Conference on Fracture - VECF1</comment>
</citation>
</ref>
<ref id="B4">
<label>4.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Chandra Sahoo</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Nimje</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Roy</surname>
<given-names>S</given-names>
</name>
</person-group>. <article-title>Strain based structural health monitoring of stiffened composite plate</article-title>. <source>Mater Today Proc</source> (<year>2022</year>). <pub-id pub-id-type="doi">10.1016/j.matpr.2022.09.432</pub-id>
</citation>
</ref>
<ref id="B5">
<label>5.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Guo</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Ding</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>Y</given-names>
</name>
<name>
<surname>Feng</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Xiong</surname>
<given-names>X</given-names>
</name>
<name>
<surname>Su</surname>
<given-names>Z</given-names>
</name>
<etal/>
</person-group> <article-title>A hierarchical deep convolutional regression framework with sensor network fail-safe adaptation for acoustic-emission-based structural health monitoring</article-title>. <source>Mech Syst Signal Process</source> (<year>2022</year>) <volume>181</volume>:<fpage>109508</fpage>. <pub-id pub-id-type="doi">10.1016/j.ymssp.2022.109508</pub-id>
</citation>
</ref>
<ref id="B6">
<label>6.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Masmoudi</surname>
<given-names>S</given-names>
</name>
<name>
<surname>El Mahi</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Turki</surname>
<given-names>S</given-names>
</name>
</person-group>. <article-title>Fatigue behaviour and structural health monitoring by acoustic emission of e-glass/epoxy laminates with piezoelectric implant</article-title>. <source>Appl Acoust Multiphysic Syst</source> (<year>2016</year>) <volume>108</volume>:<fpage>50</fpage>&#x2013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1016/j.apacoust.2015.10.024</pub-id>
</citation>
</ref>
<ref id="B7">
<label>7.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Li</surname>
<given-names>Y</given-names>
</name>
<name>
<surname>Feng</surname>
<given-names>W</given-names>
</name>
<name>
<surname>Meng</surname>
<given-names>L</given-names>
</name>
<name>
<surname>Tse</surname>
<given-names>KM</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>Z</given-names>
</name>
<name>
<surname>Huang</surname>
<given-names>L</given-names>
</name>
<etal/>
</person-group> <article-title>Investigation on <italic>in-situ</italic> sprayed, annealed and corona poled pvdf-trfe coatings for guided wave-based structural health monitoring: From crystallization to piezoelectricity</article-title>. <source>Mater Des</source> (<year>2021</year>) <volume>199</volume>:<fpage>109415</fpage>. <pub-id pub-id-type="doi">10.1016/j.matdes.2020.109415</pub-id>
</citation>
</ref>
<ref id="B8">
<label>8.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Su</surname>
<given-names>Z</given-names>
</name>
<name>
<surname>Ye</surname>
<given-names>L</given-names>
</name>
<name>
<surname>Lu</surname>
<given-names>Y</given-names>
</name>
</person-group>. <article-title>Guided lamb waves for identification of damage in composite structures: A review</article-title>. <source>J Sound Vibration</source> (<year>2006</year>) <volume>295</volume>:<fpage>753</fpage>&#x2013;<lpage>80</lpage>. <pub-id pub-id-type="doi">10.1016/j.jsv.2006.01.020</pub-id>
</citation>
</ref>
<ref id="B9">
<label>9.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Loubet</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Takacs</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Dragomirescu</surname>
<given-names>D</given-names>
</name>
</person-group>. <article-title>Implementation of a battery-free wireless sensor for cyber-physical systems dedicated to structural health monitoring applications</article-title>. <source>IEEE Access</source> (<year>2019</year>) <volume>7</volume>:<fpage>24679</fpage>&#x2013;<lpage>90</lpage>. <pub-id pub-id-type="doi">10.1109/ACCESS.2019.2900161</pub-id>
</citation>
</ref>
<ref id="B10">
<label>10.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>L&#xe9;vesque</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Asaumi</surname>
<given-names>Y</given-names>
</name>
<name>
<surname>Lord</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Bescond</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Hatanaka</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Tagami</surname>
<given-names>M</given-names>
</name>
<etal/>
</person-group> <article-title>Inspection of thick welded joints using laser-ultrasonic saft</article-title>. <source>Ultrasonics</source> (<year>2016</year>) <volume>69</volume>:<fpage>236</fpage>&#x2013;<lpage>42</lpage>. <pub-id pub-id-type="doi">10.1016/j.ultras.2016.04.001</pub-id>
</citation>
</ref>
<ref id="B11">
<label>11.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Holmes</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Drinkwater</surname>
<given-names>BW</given-names>
</name>
<name>
<surname>Wilcox</surname>
<given-names>PD</given-names>
</name>
</person-group>. <article-title>Post-processing of the full matrix of ultrasonic transmit&#x2013;receive array data for non-destructive evaluation</article-title>. <source>NDT E Int</source> (<year>2005</year>) <volume>38</volume>:<fpage>701</fpage>&#x2013;<lpage>11</lpage>. <pub-id pub-id-type="doi">10.1016/j.ndteint.2005.04.002</pub-id>
</citation>
</ref>
<ref id="B12">
<label>12.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhang</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Ren</surname>
<given-names>Y</given-names>
</name>
<name>
<surname>Song</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Zhu</surname>
<given-names>Q</given-names>
</name>
<name>
<surname>Ma</surname>
<given-names>X</given-names>
</name>
</person-group>. <article-title>The wavenumber imaging of fiber waviness in hybrid glass&#x2013;carbon fiber reinforced polymer composite plates</article-title>. <source>J Compos Mater</source> (<year>2021</year>) <volume>55</volume>:<fpage>4633</fpage>&#x2013;<lpage>43</lpage>. <pub-id pub-id-type="doi">10.1177/00219983211047692</pub-id>
</citation>
</ref>
<ref id="B13">
<label>13.</label>
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Schmidt</surname>
<given-names>RO</given-names>
</name>
</person-group>. <source>A signal subspace approach to multiple emitter location and spectral estimation</source>. <publisher-loc>United States</publisher-loc>: <publisher-name>Stanford University</publisher-name> (<year>1982</year>).</citation>
</ref>
<ref id="B14">
<label>14.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yuan</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Zhong</surname>
<given-names>Y</given-names>
</name>
<name>
<surname>Qiu</surname>
<given-names>L</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>Z</given-names>
</name>
</person-group>. <article-title>Two-dimensional near-field multiple signal classification algorithm&#x2013;based impact localization</article-title>. <source>J Intell Mater Syst Structures</source> (<year>2015</year>) <volume>26</volume>:<fpage>400</fpage>&#x2013;<lpage>13</lpage>. <pub-id pub-id-type="doi">10.1177/1045389X14529026</pub-id>
</citation>
</ref>
<ref id="B15">
<label>15.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yang</surname>
<given-names>X</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Zhou</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Xu</surname>
<given-names>L</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Sun</surname>
<given-names>P</given-names>
</name>
<etal/>
</person-group> <article-title>Ameliorated-multiple signal classification (am-music) for damage imaging using a sparse sensor network</article-title>. <source>Mech Syst Signal Process</source> (<year>2022</year>) <volume>163</volume>:<fpage>108154</fpage>. <pub-id pub-id-type="doi">10.1016/j.ymssp.2021.108154</pub-id>
</citation>
</ref>
<ref id="B16">
<label>16.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bao</surname>
<given-names>Q</given-names>
</name>
<name>
<surname>Yuan</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>Y</given-names>
</name>
<name>
<surname>Qiu</surname>
<given-names>L</given-names>
</name>
</person-group>. <article-title>Anisotropy compensated music algorithm based composite structure damage imaging method</article-title>. <source>Compos Structures</source> (<year>2019</year>) <volume>214</volume>:<fpage>293</fpage>&#x2013;<lpage>303</lpage>. <pub-id pub-id-type="doi">10.1016/j.compstruct.2019.02.036</pub-id>
</citation>
</ref>
<ref id="B17">
<label>17.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Xu</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Yin</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Deng</surname>
<given-names>M</given-names>
</name>
</person-group>. <article-title>A focusing music algorithm for baseline-free lamb wave damage localization</article-title>. <source>Mech Syst Signal Process</source> (<year>2022</year>) <volume>164</volume>:<fpage>108242</fpage>. <pub-id pub-id-type="doi">10.1016/j.ymssp.2021.108242</pub-id>
</citation>
</ref>
<ref id="B18">
<label>18.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Fan</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Yang</surname>
<given-names>L</given-names>
</name>
<name>
<surname>Zhao</surname>
<given-names>Y</given-names>
</name>
</person-group>. <article-title>Ultrasonic multi-frequency time-reversal-based imaging of extended targets</article-title>. <source>NDT E Int</source> (<year>2020</year>) <volume>113</volume>:<fpage>102276</fpage>. <pub-id pub-id-type="doi">10.1016/j.ndteint.2020.102276</pub-id>
</citation>
</ref>
<ref id="B19">
<label>19.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rossetto</surname>
<given-names>V</given-names>
</name>
<name>
<surname>Margerin</surname>
<given-names>L</given-names>
</name>
<name>
<surname>Plan&#xe8;s</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Larose</surname>
<given-names>R</given-names>
</name>
</person-group>. <article-title>Locating a weak change using diffuse waves: Theoretical approach and inversion procedure</article-title>. <source>J Appl Phys</source> (<year>2011</year>) <volume>109</volume>:<fpage>034903</fpage>. <pub-id pub-id-type="doi">10.1063/1.3544503</pub-id>
</citation>
</ref>
<ref id="B20">
<label>20.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Planes</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Larose</surname>
<given-names>E</given-names>
</name>
<name>
<surname>Rossetto</surname>
<given-names>V</given-names>
</name>
<name>
<surname>Margerin</surname>
<given-names>L</given-names>
</name>
</person-group>. <article-title>Locadiff: Locating a weak change with diffuse ultrasound</article-title>. <source>AIP Conf Proc</source> (<year>2013</year>) <volume>1511</volume>:<fpage>405</fpage>&#x2013;<lpage>11</lpage>. <pub-id pub-id-type="doi">10.1063/1.4789076</pub-id>
</citation>
</ref>
<ref id="B21">
<label>21.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pacheco</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Snieder</surname>
<given-names>R</given-names>
</name>
</person-group>. <article-title>Time-lapse traveltime change of singly scattered acoustic waves</article-title>. <source>Geophys J Int</source> (<year>2006</year>) <volume>165</volume>:<fpage>485</fpage>&#x2013;<lpage>500</lpage>. <pub-id pub-id-type="doi">10.1111/j.1365-246X.2006.02856.x</pub-id>
</citation>
</ref>
<ref id="B22">
<label>22.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Plan&#xe8;s</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Larose</surname>
<given-names>E</given-names>
</name>
<name>
<surname>Rossetto</surname>
<given-names>V</given-names>
</name>
<name>
<surname>Margerin</surname>
<given-names>L</given-names>
</name>
</person-group>. <article-title>Imaging multiple local changes in heterogeneous media with diffuse waves</article-title>. <source>The J Acoust Soc America</source> (<year>2015</year>) <volume>137</volume>:<fpage>660</fpage>&#x2013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1121/1.4906824</pub-id>
</citation>
</ref>
<ref id="B23">
<label>23.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Xie</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Moreau</surname>
<given-names>L</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>Y</given-names>
</name>
<name>
<surname>Larose</surname>
<given-names>E</given-names>
</name>
</person-group>. <article-title>A bayesian approach for high resolution imaging of small changes in multiple scattering media</article-title>. <source>Ultrasonics</source> (<year>2016</year>) <volume>64</volume>:<fpage>106</fpage>&#x2013;<lpage>14</lpage>. <pub-id pub-id-type="doi">10.1016/j.ultras.2015.08.005</pub-id>
</citation>
</ref>
<ref id="B24">
<label>24.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Broucke</surname>
<given-names>BVD</given-names>
</name>
<name>
<surname>Hamila</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Lomov</surname>
<given-names>SV</given-names>
</name>
<name>
<surname>Boisse</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Verpoest</surname>
<given-names>I</given-names>
</name>
</person-group>. <article-title>Determination of the mechanical properties of textile-reinforced composites taking into account textile forming parameters</article-title>. <source>Int J Mater Form</source> (<year>2010</year>) <volume>3</volume>:<fpage>1351</fpage>&#x2013;<lpage>61</lpage>. <pub-id pub-id-type="doi">10.1007/s12289-009-0680-9</pub-id>
</citation>
</ref>
<ref id="B25">
<label>25.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Biwa</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Kamiya</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Ohno</surname>
<given-names>N</given-names>
</name>
</person-group>. <article-title>Multiple scattering simulation of ultrasonic shear wave in unidirectional carbon/epoxy composites</article-title>. <source>Mater Trans</source> (<year>2007</year>) <volume>48</volume>:<fpage>1196</fpage>&#x2013;<lpage>201</lpage>. <pub-id pub-id-type="doi">10.2320/matertrans.I-MRA2007846</pub-id>
</citation>
</ref>
<ref id="B26">
<label>26.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hosseini</surname>
<given-names>SMH</given-names>
</name>
<name>
<surname>Willberg</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Kharaghani</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Gabbert</surname>
<given-names>U</given-names>
</name>
</person-group>. <article-title>Characterization of the guided wave propagation in simplified foam, honeycomb and hollow sphere structures</article-title>. <source>Composites B: Eng</source> (<year>2014</year>) <volume>56</volume>:<fpage>553</fpage>&#x2013;<lpage>66</lpage>. <pub-id pub-id-type="doi">10.1016/j.compositesb.2013.08.077</pub-id>
</citation>
</ref>
<ref id="B27">
<label>27.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Weber</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Hosseini</surname>
<given-names>SMH</given-names>
</name>
<name>
<surname>Gabbert</surname>
<given-names>U</given-names>
</name>
</person-group>. <article-title>Numerical simulation of the guided lamb wave propagation in particle reinforced composites</article-title>. <source>Compos Structures</source> (<year>2012</year>) <volume>94</volume>:<fpage>3064</fpage>&#x2013;<lpage>71</lpage>. <pub-id pub-id-type="doi">10.1016/j.compstruct.2012.04.020</pub-id>
</citation>
</ref>
<ref id="B28">
<label>28.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Treebya</surname>
<given-names>BE</given-names>
</name>
<name>
<surname>Jaros</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Rendell</surname>
<given-names>AP</given-names>
</name>
<name>
<surname>Cox</surname>
<given-names>BT</given-names>
</name>
</person-group>. <article-title>Modeling nonlinear ultrasound propagation in heterogeneous media with power law absorption using a k-space pseudospectral method</article-title>. <source>J Acoust Soc America</source> (<year>2012</year>) <volume>131</volume>:<fpage>4324</fpage>&#x2013;<lpage>36</lpage>. <pub-id pub-id-type="doi">10.1121/1.4712021</pub-id>
</citation>
</ref>
<ref id="B29">
<label>29.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Scholz</surname>
<given-names>M-S</given-names>
</name>
<name>
<surname>Drinkwater</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Trask</surname>
<given-names>R</given-names>
</name>
</person-group>. <article-title>Ultrasonic assembly of anisotropic short fibre reinforced composites</article-title>. <source>Ultrasonics</source> (<year>2014</year>) <volume>54</volume>:<fpage>1015</fpage>&#x2013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1016/j.ultras.2013.12.001</pub-id>
</citation>
</ref>
<ref id="B30">
<label>30.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Fayazbakhsh</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Movahedi</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Kalman</surname>
<given-names>J</given-names>
</name>
</person-group>. <article-title>The impact of defects on tensile properties of 3d printed parts manufactured by fused filament fabrication</article-title>. <source>Mater Today Commun</source> (<year>2019</year>) <volume>18</volume>:<fpage>140</fpage>&#x2013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1016/j.mtcomm.2018.12.003</pub-id>
</citation>
</ref>
<ref id="B31">
<label>31.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kino</surname>
<given-names>GS</given-names>
</name>
</person-group>. <article-title>The application of reciprocity theory to scattering of acoustic waves by flaws</article-title>. <source>J Appl Phys</source> (<year>1978</year>) <volume>49</volume>:<fpage>3190</fpage>&#x2013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1063/1.325312</pub-id>
</citation>
</ref>
<ref id="B32">
<label>32.</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Willaims</surname>
<given-names>JH</given-names>
<suffix>Jr.</suffix>
</name>
<name>
<surname>Nayeb-Hashemi</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>SS</given-names>
</name>
</person-group>. <article-title>Ultrasonic attenuation and velocity in as/3501-6 graphite fiber composite</article-title>. <source>J Nondestr Eval</source> (<year>1980</year>) <volume>1</volume>:<fpage>137</fpage>&#x2013;<lpage>48</lpage>. <pub-id pub-id-type="doi">10.1007/bf00566121</pub-id>
</citation>
</ref>
</ref-list>
</back>
</article>