<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Phys.</journal-id>
<journal-title>Frontiers in Physics</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Phys.</abbrev-journal-title>
<issn pub-type="epub">2296-424X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fphy.2021.665562</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Physics</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Feasibility of Hepatic Fat Quantification Using Proton Density Fat Fraction by Multi-Echo Chemical-Shift-Encoded MRI at 7T</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name><surname>Ko&#x00159;&#x000ED;nek</surname> <given-names>Radim</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/1206835/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Pfleger</surname> <given-names>Lorenz</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Eckstein</surname> <given-names>Korbinian</given-names></name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Beiglb&#x000F6;ck</surname> <given-names>Hannes</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Robinson</surname> <given-names>Simon Daniel</given-names></name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/52029/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Krebs</surname> <given-names>Michael</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/1259807/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Trattnig</surname> <given-names>Siegfried</given-names></name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<xref ref-type="aff" rid="aff4"><sup>4</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Star&#x0010D;uk</surname> <given-names>Zenon</given-names> <suffix>Jr.</suffix></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name><surname>Kr&#x00161;&#x00161;&#x000E1;k</surname> <given-names>Martin</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<xref ref-type="aff" rid="aff4"><sup>4</sup></xref>
<xref ref-type="corresp" rid="c001"><sup>&#x0002A;</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/426828/overview"/>
</contrib>
</contrib-group>
<aff id="aff1"><sup>1</sup><institution>Magnetic Resonance group, Institute of Scientific Instruments of the Czech Academy of Sciences</institution>, <addr-line>Brno</addr-line>, <country>Czechia</country></aff>
<aff id="aff2"><sup>2</sup><institution>Division of Endocrinology and Metabolism, Department of Medicine III, Medical University of Vienna</institution>, <addr-line>Vienna</addr-line>, <country>Austria</country></aff>
<aff id="aff3"><sup>3</sup><institution>Department of Biomedical Imaging and Image-Guided Therapy, High-Field Magnetic Resonance Centre, Medical University of Vienna</institution>, <addr-line>Vienna</addr-line>, <country>Austria</country></aff>
<aff id="aff4"><sup>4</sup><institution>Christian Doppler Laboratory for Clinical Molecular Imaging, CD Laboratory for Clinical Molecular MR Imaging (MOLIMA), Medical University of Vienna</institution>, <addr-line>Vienna</addr-line>, <country>Austria</country></aff>
<author-notes>
<fn fn-type="edited-by"><p>Edited by: Nirbhay Yadav, Johns Hopkins University, United States</p></fn>
<fn fn-type="edited-by"><p>Reviewed by: Simon Auguste Lambert, Universit&#x000E9; Claude Bernard Lyon 1, France; Christian Herbert Ziener, German Cancer Research Center (DKFZ), Germany</p></fn>
<corresp id="c001">&#x0002A;Correspondence: Martin Kr&#x00161;&#x00161;&#x000E1;k <email>martin.krssak&#x00040;meduniwien.ac.at</email></corresp>
<fn fn-type="other" id="fn001"><p>This article was submitted to Medical Physics and Imaging, a section of the journal Frontiers in Physics</p></fn></author-notes>
<pub-date pub-type="epub">
<day>07</day>
<month>05</month>
<year>2021</year>
</pub-date>
<pub-date pub-type="collection">
<year>2021</year>
</pub-date>
<volume>9</volume>
<elocation-id>665562</elocation-id>
<history>
<date date-type="received">
<day>08</day>
<month>02</month>
<year>2021</year>
</date>
<date date-type="accepted">
<day>29</day>
<month>03</month>
<year>2021</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x000A9; 2021 Ko&#x00159;&#x000ED;nek, Pfleger, Eckstein, Beiglb&#x000F6;ck, Robinson, Krebs, Trattnig, Star&#x0010D;uk and Kr&#x00161;&#x00161;&#x000E1;k.</copyright-statement>
<copyright-year>2021</copyright-year>
<copyright-holder>Ko&#x00159;&#x000ED;nek, Pfleger, Eckstein, Beiglb&#x000F6;ck, Robinson, Krebs, Trattnig, Star&#x0010D;uk and Kr&#x00161;&#x00161;&#x000E1;k</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license> </permissions>
<abstract><p>Fat fraction quantification and assessment of its distribution in the hepatic tissue become more important with the growing epidemic of obesity, and the increasing prevalence of diabetes mellitus type 2 and non-alcoholic fatty liver disease. At 3Tesla, the multi-echo, chemical-shift-encoded magnetic resonance imaging (CSE-MRI)-based acquisition allows the measurement of proton density fat-fraction (PDFF) even in clinical protocols. Further improvements in SNR can be achieved by the use of phased array coils and increased static magnetic field. The purpose of the study is to evaluate the feasibility of PDFF imaging using a multi-echo CSE-MRI technique at ultra-high magnetic field (7Tesla). Thirteen volunteers (M/F) with a broad range of age, body mass index, and hepatic PDFF were measured at 3 and 7T by multi-gradient-echo MRI and single-voxel spectroscopy MRS. All measurements were performed in breath-hold (exhalation); the MRI protocols were optimized for a short measurement time, thus minimizing motion-related problems. 7T data were processed off-line using Matlab&#x000AE; (MRI:multi-gradient-echo) and jMRUI (MRS), respectively. For quantitative validation of the PDFF results, a similar protocol was performed at 3T, including on-line data processing provided by the system manufacturer, and correlation analyses between 7 and 3T data were performed off-line. The multi-echo CSE-MRI measurements at 7T with a phased-array coil configuration and an optimal post-processing yielded liver volume coverage ranging from 30 to 90% for high- and low-BMI subjects, respectively. PDFFs ranged between 1 and 20%. We found significant correlations between 7T MRI and -MRS measurements (<italic>R</italic><sup>2</sup> &#x02245; 0.97; <italic>p</italic> &#x0003C; 0.005), and between MRI-PDFF at 7T and 3T fields (<italic>R</italic><sup>2</sup> &#x02245; 0.94; <italic>p</italic> &#x0003C; 0.005) in the evaluated volumes. Based on the measurements and analyses performed, the multi-echo CSE-MRI method using a 32-channel coil at 7T showed its aptitude for MRI-based quantitation of PDFF in the investigated volumes. The results are the first step toward qMRI of the whole liver at 7T with further improvements in hardware.</p></abstract>
<kwd-group>
<kwd>CSE-MRI</kwd>
<kwd>ultra-high magnetic field</kwd>
<kwd>7T</kwd>
<kwd>feasibility</kwd>
<kwd>liver</kwd>
<kwd>PDFF</kwd>
</kwd-group>
<counts>
<fig-count count="4"/>
<table-count count="0"/>
<equation-count count="0"/>
<ref-count count="71"/>
<page-count count="9"/>
<word-count count="6602"/>
</counts>
</article-meta>
</front>
<body>
<sec sec-type="intro" id="s1">
<title>Introduction</title>
<p>The importance of fat fraction quantification and distribution in the human tissue is growing with the epidemic of obesity, and the increasing prevalence of diabetes mellitus type 2 (T2DM) [<xref ref-type="bibr" rid="B1">1</xref>, <xref ref-type="bibr" rid="B2">2</xref>] and non-alcoholic fatty liver disease (NAFLD) [<xref ref-type="bibr" rid="B3">3</xref>&#x02013;<xref ref-type="bibr" rid="B5">5</xref>].</p>
<p>Modern 3T clinical MR systems, providing high signal-to-noise ratio (SNR) and high resolution, allow the measurement of tissue proton density fat fraction (PDFF) [<xref ref-type="bibr" rid="B6">6</xref>, <xref ref-type="bibr" rid="B7">7</xref>] even in routine clinical protocols. Multi-echo data is required to achieve accurate fat quantification based on Chemical Shift Encoded Magnetic Resonance Imaging (CSE-MRI) [<xref ref-type="bibr" rid="B8">8</xref>&#x02013;<xref ref-type="bibr" rid="B13">13</xref>]. To determine of accurate PDFF distribution in the inner organs, high image resolution is required. Then, however, the SNR is reduced and subsequent data processing, in which the PDFF is calculated for each image voxel/pixel, is adversely affected. In principle, the SNR can be increased by the use of phased array RF (multi-channel) coils [<xref ref-type="bibr" rid="B14">14</xref>&#x02013;<xref ref-type="bibr" rid="B16">16</xref>] and/or increased static magnetic field [<xref ref-type="bibr" rid="B17">17</xref>&#x02013;<xref ref-type="bibr" rid="B19">19</xref>], both having some practical limits and incurring higher costs of hardware [<xref ref-type="bibr" rid="B20">20</xref>]. Recent installations of ultra-high-field (UHF) MR systems (7T or more), along with improvements in RF hardware and acquisition methods, have clearly demonstrated superior data quality for neuro- and musculoskeletal imaging [<xref ref-type="bibr" rid="B21">21</xref>, <xref ref-type="bibr" rid="B22">22</xref>]. Nevertheless, problems remain; in particular, the abdominal region is affected by water-fat displacement and stronger susceptibility artifacts. Moreover, at high fields, the chemical shifts between the water peak and the multiple spectral peaks in the fat signal are increased. To minimize chemical shift displacement, strong gradients and large acquisition bandwidths must be used, causing SNR reduction and potentially substantial eddy currents [<xref ref-type="bibr" rid="B23">23</xref>, <xref ref-type="bibr" rid="B24">24</xref>]. The other UHF effects are a prolongation of relaxation time <italic>T</italic><sub>1</sub> and a shortening of <italic>T</italic><sub>2</sub> and <inline-formula><mml:math id="M1"><mml:msubsup><mml:mrow><mml:mi>T</mml:mi></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow><mml:mrow><mml:mo>&#x0002A;</mml:mo></mml:mrow></mml:msubsup></mml:math></inline-formula> relaxation times [<xref ref-type="bibr" rid="B25">25</xref>&#x02013;<xref ref-type="bibr" rid="B27">27</xref>]. An important parameter in UHF MR for patient safety is the specific absorption rate (SAR), which, in principle, increases quadratically with <italic>B</italic><sub>0</sub> field, but the specific spatial pattern depends in a complex way on the <italic>B</italic><sub>1</sub> frequency and a variety of factors, including the subject [<xref ref-type="bibr" rid="B28">28</xref>, <xref ref-type="bibr" rid="B29">29</xref>]. These factors are a problem mainly with whole-body or large-volume coverage coils, such as birdcage, saddle, and TEM coils. A related UHF-MR problem is inhomogeneity of the excitation RF-field (<inline-formula><mml:math id="M2"><mml:msubsup><mml:mrow><mml:mi>B</mml:mi></mml:mrow><mml:mrow><mml:mn>1</mml:mn></mml:mrow><mml:mrow><mml:mo>&#x0002B;</mml:mo></mml:mrow></mml:msubsup></mml:math></inline-formula>), which leads to inhomogeneous excitation and errors in quantitative imaging if not properly addressed. To overcome the problems of heterogeneous SAR, excitation, and detection sensitivity, dedicated multi-channel RF coils in transmit and receive modes [<xref ref-type="bibr" rid="B30">30</xref>&#x02013;<xref ref-type="bibr" rid="B33">33</xref>] have been used and field-specific adaptations to MR acquisition protocols have been implemented [<xref ref-type="bibr" rid="B34">34</xref>, <xref ref-type="bibr" rid="B35">35</xref>].</p>
<p>CSE-MRI-based quantification of PDFF is a fast and reliable way to determine the distribution of fat in a tissue. This approach, proposed by Dixon [<xref ref-type="bibr" rid="B36">36</xref>] in 1984, has undergone considerable changes and evolution [<xref ref-type="bibr" rid="B8">8</xref>, <xref ref-type="bibr" rid="B9">9</xref>, <xref ref-type="bibr" rid="B13">13</xref>, <xref ref-type="bibr" rid="B37">37</xref>, <xref ref-type="bibr" rid="B38">38</xref>]. These various changes are frequently called &#x0201C;Dixon&#x0201D; methods even for multi-echo approaches; however, the term &#x0201C;CSE-MRI&#x0201D; is usually used for advanced methods that include a multi-echo acquisition scheme. Generally, the signal model representing the behavior of a vector of magnetization during the measurement sequence is crucial for the calculation of correct MRI-PDFF values. Due to the complex lipid spectrum [<xref ref-type="bibr" rid="B6">6</xref>, <xref ref-type="bibr" rid="B39">39</xref>, <xref ref-type="bibr" rid="B40">40</xref>], which contains several spectral lines in the frequency range of &#x0007E;4.5 ppm (main peak at 1.3 ppm -CH<sub>2</sub>-), the signal model must contain prior knowledge about the spectral position and the relative intensity of each peak. A further common problem of all &#x0201C;Dixon&#x0201D;/CSE-MRI water-fat separation methods is field map (B<sub>0</sub>) estimation [<xref ref-type="bibr" rid="B11">11</xref>, <xref ref-type="bibr" rid="B41">41</xref>]. At higher static magnetic fields, larger local magnetic field gradients result in more phase overflows of 2&#x003C0; in complex images compared to those at lower fields. The occurrence of these phase wraps may lead to water-fat swaps in the calculated MRI-PDFF maps, necessitating the application of phase-unwrapping algorithms. Several approaches have addressed this problem successfully [<xref ref-type="bibr" rid="B37">37</xref>, <xref ref-type="bibr" rid="B41">41</xref>]. In hepatic iron overload, especially at excessive concentration, the tissue signal is significantly dephased, and hence, <inline-formula><mml:math id="M3"><mml:msubsup><mml:mrow><mml:mtext>T</mml:mtext></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow><mml:mrow><mml:mo>&#x0002A;</mml:mo></mml:mrow></mml:msubsup></mml:math></inline-formula> relaxation is distinctly shortened; thus, the <inline-formula><mml:math id="M4"><mml:msubsup><mml:mrow><mml:mtext>R</mml:mtext></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow><mml:mrow><mml:mo>&#x0002A;</mml:mo></mml:mrow></mml:msubsup></mml:math></inline-formula> = 1/<inline-formula><mml:math id="M5"><mml:msubsup><mml:mrow><mml:mtext>T</mml:mtext></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow><mml:mrow><mml:mo>&#x0002A;</mml:mo></mml:mrow></mml:msubsup></mml:math></inline-formula> must be included in the signal model [<xref ref-type="bibr" rid="B8">8</xref>]; otherwise, substantial errors in PDFF estimation [<xref ref-type="bibr" rid="B42">42</xref>, <xref ref-type="bibr" rid="B43">43</xref>] may occur.</p>
<p>In fact, the current clinical 3T protocols for PDFF measurements collect data in low resolution due to the requirement for a short measurement time (breath-hold) and a good SNR. The full coverage of the abdominal space is standard at 3T; however, the lower resolution smooths the information about the fat or iron distribution in the liver. This is a potential problem for the detailed study of fat distribution in the liver. Higher resolution that prolongs measurement time influences other measuring parameters (TE, TR, BW, and many others), and mainly deteriorates SNR in acquired data, which leads to noisy parametric maps (PDFF, R2<sup>&#x0002A;</sup>). Generally, quantitative magnetic resonance imaging (qMRI) is a crucial component of the many therapies and diagnostic [<xref ref-type="bibr" rid="B44">44</xref>], and provides the relatively stable and reproducible results [<xref ref-type="bibr" rid="B45">45</xref>]. The using of high field potentially yield benefit in the form of higher SNR compare to a low field, and it can improve the qMRI [<xref ref-type="bibr" rid="B46">46</xref>]. We have to note at the outset that due to incomparable coil configuration, the quality of images is not compared (SNR) in the study (it would not be objective); and the main focus is on the comparison of the quantitative results from both magnetic field, 3 and 7T. This study is the first step in exploring the possibilities of abdominal quantitative MRI (qMRI) that could provide improvement in diagnostic accuracy for a wide range of chronic liver diseases due to higher sensitivity at 7T in combination with the appropriate hardware equipment.</p>
<p>The purpose of this study was to assess the feasibility of proton density fat fraction (PDFF) quantification using multi-echo MRI at 7T with a 32-channel phase-array coil without <italic>B</italic><sub>1</sub> shimming. To demonstrate the potential value of the method at UHF with the best possible available hardware configuration at our institution (at the time of the study), PDFF derived from 7T MRI measurement (MRI-PDFF) was compared to PDFF determined by 7T MRS (MRS-PDFF) and to gold-standard [<xref ref-type="bibr" rid="B47">47</xref>, <xref ref-type="bibr" rid="B48">48</xref>] multi-echo MRI-based 3T measurements [<xref ref-type="bibr" rid="B49">49</xref>, <xref ref-type="bibr" rid="B50">50</xref>] on the same group of subjects.</p>
</sec>
<sec sec-type="materials and methods" id="s2">
<title>Materials and Methods</title>
<sec>
<title>Subjects</title>
<p>Thirteen subjects (4f/9m; age, 44.7 &#x000B1; 14.7 years; body mass index (BMI) 25.6 &#x000B1; 4.7 kg.m<sup>&#x02212;2</sup>; mean &#x000B1; SD) participated in this study. Volunteers were recruited based on the hepatic PDFF values obtained in previous studies [<xref ref-type="bibr" rid="B51">51</xref>&#x02013;<xref ref-type="bibr" rid="B53">53</xref>] to cover a broad range of PDFFs (0&#x02013;20%) without a focus on their respective health status or diagnosis. The group comprised six lean volunteers (BMI = 21.7 &#x000B1; 1.9 kg.m<sup>&#x02212;2</sup>) and seven volunteers with high BMI (BMI = 29.6 &#x000B1; 2.7 kg.m<sup>&#x02212;2</sup>).</p>
<sec>
<title>Ethics Statement</title>
<p>The study was approved by the local ethics committee. Informed consent was obtained from all individual participants included in the study.</p>
</sec>
</sec>
<sec>
<title>Acquisition and Reconstruction</title>
<sec>
<title>7T Measurements</title>
<p>At 7T (MAGNETOM, Siemens Healthineers, Erlangen, Germany), a phased array receive/transmit surface (32-channel) coil (Cardiac Transceiver Array RF Coil, MRI.TOOLS GmbH) was used. MR image data were acquired with an accelerated 3D-SPGR sequence with bipolar readout gradients with the following parameters: field of view (FOV) = 38.0 cm &#x000D7; 33.2 cm; acquisition bandwidth (BW) = 1,395 Hz/pixel; repetition time (<italic>T</italic><sub>R</sub>) = 9.6 ms; flip angle (FA) = 4&#x000B0;; 32 slices (slice gap of 20%); acquisition matrix size in-plane = 256 &#x000D7; 224 pixels; voxel size 0.74 &#x000D7; 0.74 &#x000D7; 4 mm<sup>3</sup>; and six echoes with an equidistant echo spacing of &#x00394;<italic>T</italic><sub>E</sub> = 1.81 ms (the shortest possible), where the first <italic>T</italic><sub>E</sub> = 1.45 ms, and acquisition time <italic>T</italic><sub>A</sub> = 11.8 s, with a GRAPPA [<xref ref-type="bibr" rid="B54">54</xref>] acceleration factor of 8. Multi-channel multi-echo data were combined with the scanner image reconstructor using ASPIRE [<xref ref-type="bibr" rid="B55">55</xref>] and the PDFF maps were generated using the Graph-Cut approach [<xref ref-type="bibr" rid="B37">37</xref>] in a MATLAB&#x000AE; toolbox [<xref ref-type="bibr" rid="B56">56</xref>, <xref ref-type="bibr" rid="B57">57</xref>], including the prior knowledge of the multi-frequency fat spectrum [<xref ref-type="bibr" rid="B39">39</xref>]. Single-voxel proton spectroscopic measurements were performed using a modified STEAM sequence [<xref ref-type="bibr" rid="B27">27</xref>] with <italic>T</italic><sub>R</sub> = 5 s, with echo times <italic>T</italic><sub>E</sub> = 6, 12, and 20 ms, <italic>T</italic><sub>M</sub> = 10 ms, and a voxel size of 30 &#x000D7; 30 &#x000D7; 30 mm<sup>3</sup>. Due to a relatively narrow frequency bandwidth of the excitation pulse, the measurement was repeated with the same parameters, but with the excitation frequency (delta frequency) offset by &#x02212;3.4 ppm from the water frequency (4.7 ppm) to fully cover the frequency band around the main fat resonances at 1.3 ppm (CH<sub>3</sub>). The acquired spectra were evaluated in jMRUI [<xref ref-type="bibr" rid="B58">58</xref>] with the AMARES fitting algorithm [<xref ref-type="bibr" rid="B59">59</xref>, <xref ref-type="bibr" rid="B60">60</xref>] with a prior knowledge of the fat spectral components [<xref ref-type="bibr" rid="B39">39</xref>]. The MRS-based PDFF was calculated from <italic>T</italic><sub>2</sub>-corrected spectra as the ratio of the estimated relative proton density of mobile lipids to the sum of the estimated relative proton densities of mobile water and mobile lipids.</p>
</sec>
<sec>
<title>3T Measurements</title>
<p>At 3T (Trio/PrismaFit, Siemens Healthineers, Erlangen, Germany), a combination of phased-array abdominal (18 channels) and spinal (32-channel) receiver coils and a whole-body transmit coil supplied by the MR-system manufacturer was used for data acquisition. MR image data were acquired by an accelerated 3D-SPGR (Spoiled Gradient Echo) [<xref ref-type="bibr" rid="B61">61</xref>] sequence with unipolar readout gradients with the following parameters: FOV = 38.0 cm &#x000D7; 31.4 cm; BW = 1.040 Hz/pixel; <italic>T</italic><sub>R</sub> = 9.32 ms; FA = 3&#x000B0; (to minimize <italic>T</italic><sub>1</sub> effects); 48 slices (slice gap of 20%); acquisition matrix size in-plane = 160 &#x000D7; 104 pixels (interpolated to 320 &#x000D7; 264 pixels); voxel size 1.2 &#x000D7; 1.2 &#x000D7; 3.5 mm<sup>3</sup>; and six echoes with an equidistant echo spacing of &#x00394;<italic>T</italic><sub>E</sub> = 1.31 ms, where the first <italic>T</italic><sub>E</sub> = 1.23 ms, <italic>T</italic><sub>A</sub> = 6.9 s, and a CAIPIRINHA [<xref ref-type="bibr" rid="B62">62</xref>, <xref ref-type="bibr" rid="B63">63</xref>] acceleration factor of 4 (2 &#x000D7; 2). The MRI protocol contains the online water-fat separation provided by the system manufacturer, which allows direct visualization of PDFF maps immediately after the acquisition. Those maps were used in our evaluation. The implemented online water-fat separation is certified for clinical use; therefore, such reconstructed data (PDFF maps) were used as the 3T MRI reference. Moreover, supplementary PDFF maps were reconstructed from 3T MRI data using the same approach as in 7T to allow a comparison of the same processing algorithm applied to data from different magnetic fields.</p>
</sec>
</sec>
<sec>
<title>Volume of Interest Selection</title>
<p>The VOI for the 7T MRI-PDFF (similar or almost identical volumes compare to MRS) data analysis and 7T MRS data acquisition was placed in a homogeneous hepatic tissue carefully chosen to avoid contamination from liver vessels and subcutaneous tissue, but in the vicinity of the multi-channel coil, thus ensuring the best possible signal-to-noise. Selection of a VOI (similar size as 7T case) in the same position was attempted on the 3T PDFF maps.</p>
</sec>
<sec>
<title>Effective Liver Volume Coverage</title>
<p>To evaluate the range of coil combinations used at 7T, the term &#x0201C;effective liver volume coverage&#x0201D; was introduced where the liver volume at 7T was compared with the &#x0201C;true liver volume.&#x0201D; The &#x0201C;true liver volume&#x0201D; was estimated from 3T images for each subject where the full coverage of the abdominal region (not only the liver) was expected (100% coverage); the liver segmentation was performed manually. At 7T, the image noise thresholding segmentations on measured data (echo images of each subject for the longest <italic>T</italic><sub>E</sub>) were performed to identify the background noise regions in the images, and these masks were applied to the measured data to achieve masked images. Subsequently, the liver was manually segmented from the masked images.</p>
</sec>
<sec>
<title>Statistical Analyses</title>
<p>The reconstructed 3T- and 7T-MRI-PDFF data where displayed in a box-and-whisker diagram to show the distribution of fat within the investigated VOIs for each subject. To prove the relations between 7T-MRI, 3T-MRI and 7T-MRS PDFF measurements, linear regression and Bland-Altman analyses were performed. All statistical tests were performed in MATLAB (MathWorks, Natick, MA, USA).</p>
</sec>
</sec>
<sec sec-type="results" id="s3">
<title>Results</title>
<p>Examples of the acquired MRI-PDFF volumes for two subjects with different body sizes and composition, and with high (S6) and low (S3) BMI, at 3 and 7T, are shown in <xref ref-type="fig" rid="F1">Figure 1</xref> (and related figures of PDFFs with corresponding 7T anatomical images in <xref ref-type="supplementary-material" rid="SM1">Supplementary Material 1</xref>). The position of the spectroscopic volume of interest (VOI) and the ROI used for the comparison is delineated for each subject by the white box in the respective PDFF map; the calculated field maps are shown in <xref ref-type="supplementary-material" rid="SM2">Supplementary Material 2</xref>. The effective liver volume coverage for MRI-PDFF showed 100% of the liver volume, as well as the whole abdomen for all subjects at 3T. In the case of the 32-channel RF coil used at 7T, the effective liver volume coverage varied from &#x0007E;30 to 90% based on body size and composition. Liver coverage was highest in the subjects with low BMI and smaller body (torso) size (example in <xref ref-type="supplementary-material" rid="SM1">Figure 1</xref> S13, <xref ref-type="supplementary-material" rid="SM1">Supplementary Figures 1</xref>, <xref ref-type="supplementary-material" rid="SM1">3</xref> in <xref ref-type="supplementary-material" rid="SM1">Supplementary Material 1</xref>). A case of a subject with very high BMI and non-optimal body size is shown in <xref ref-type="supplementary-material" rid="SM1">Figure 1</xref> S6 and <xref ref-type="supplementary-material" rid="SM1">Supplementary Figures 1</xref>, <xref ref-type="supplementary-material" rid="SM1">2</xref> in <xref ref-type="supplementary-material" rid="SM1">Supplementary Material 1</xref>. The whiskers diagrams (<xref ref-type="fig" rid="F2">Figure 2</xref>) show the distributions of MRI-PDFF within the VOI and the related MRS-PDFF values acquired from similar or almost identical volumes.</p>
<fig id="F1" position="float">
<label>Figure 1</label>
<caption><p>Positions of VOIs in the cranial section of the liver of subjects S6 and S13 with lowest and highest BMI (within the experimental group of our subjects), respectively. The investigated region is depicted by white solid boxes across the volume. The 7T data are noisy due to higher resolution and bandwidth per pixel compare to 3T.</p></caption>
<graphic xlink:href="fphy-09-665562-g0001.tif"/>
</fig>
<fig id="F2" position="float">
<label>Figure 2</label>
<caption><p>The distributions of MRI-PDFF for individual subjects at 3T (yellow boxes) and 7T (blue boxes). The related 7T-MRS-PDFF values are depicted by black solid horizontal crosses. The red horizontal lines in the bars are the medians and the dark blue solid oblique crosses are the mean values of these distributions. The bottom and top of the boxes represent the 25th and 75th percentile (Q1 and Q3 quartiles) of MRI-PDFF distributions. The ends (black horizontal lines) of the extended whiskers (dashed black lines) define upper and lower extremes (&#x000B1; 2.7&#x003C3; &#x02248; 99.3% coverage).</p></caption>
<graphic xlink:href="fphy-09-665562-g0002.tif"/>
</fig>
<p>The correlation analyses for the data presented in <xref ref-type="fig" rid="F2">Figure 2</xref> are shown in <xref ref-type="fig" rid="F3">Figure 3</xref>, where the 7T-MRI-PDFFs are compared with (<xref ref-type="fig" rid="F3">Figure 3A</xref>) 3T-MRI, and (<xref ref-type="fig" rid="F3">Figure 3B</xref>) 7T-MRS PDFF values. In the both cases A and B (<xref ref-type="fig" rid="F3">Figure 3</xref>), high <italic>R</italic><sup>2</sup>-values with low <italic>p</italic>-values, indicating strong agreement between the 3T and 7T measurements, were observed. The calculated <italic>R</italic><sup>2</sup>-values (with <italic>p</italic>-values) of A and B (<xref ref-type="fig" rid="F3">Figure 3</xref>) cases were 0.936 (<italic>p</italic> &#x02248; 2.75&#x000B7;10<sup>&#x02212;7</sup>; 7T MRI vs. 3T MRI) and 0.970 (<italic>p</italic> &#x02248; 1.32&#x000B7;10<sup>&#x02212;6</sup>; 7T MRI vs. 7T MRS), respectively; in addition, the slopes were calculated. Then, the Bland-Altman (BA) analyses of the previous (A) and (B) cases were also performed, which can be seen in <xref ref-type="fig" rid="F4">Figure 4</xref>. In the first case, the BA plot shows a mean difference (bias) of &#x02248;-0.60% and upper and lower confidence intervals (CI of 95%) of 0.58 and &#x02212;1.79%, respectively. In the second case (<xref ref-type="fig" rid="F4">Figure 4</xref> on the right), there was a mean difference (bias) of &#x02248;-0.54% and upper and lower confidence intervals (CI of 95%) of 0.52 and &#x02212;1.60%, respectively. The extended boxplots and related analyses of PDFF maps that were calculated by the offline toolbox using Graph-Cut algorithm/approach from 3T-MRI data are given in <xref ref-type="supplementary-material" rid="SM3">Supplementary Material 3</xref>.</p>
<fig id="F3" position="float">
<label>Figure 3</label>
<caption><p>The correlation analysis of <bold>(A)</bold> 7T-MRI-PDFF vs. 3T-MRI-PDFF, and <bold>(B)</bold> 7T-MRI-PDFF vs. 7T-MRS-PDFF. The red line represents the linear fit of the values, and 95% confidence intervals for the slope of the lines are depicted by red dotted lines (upper and lower bounds). The black dashed line corresponds to a perfect match. &#x0002A;Its data point.</p></caption>
<graphic xlink:href="fphy-09-665562-g0003.tif"/>
</fig>
<fig id="F4" position="float">
<label>Figure 4</label>
<caption><p>The Bland Altman analysis for (left) 3T and 7T MRI, and (right) 7T MRI and MRS measurements. The red line depicts the mean difference (bias) of all measurements, and the blue dotted lines represent the 95% confidence intervals for the mean.</p></caption>
<graphic xlink:href="fphy-09-665562-g0004.tif"/>
</fig>
<p>In subject S2, the 7T MRS measurement was not performed because of health problems (cramps) not related to the measurement. The reconstructed (7T) MRI-PDFF maps (mainly the volume of interest) from S10 were affected by strong water-fat swaps that could not be removed by changing the parameters of the algorithm used, and therefore, the results were excluded. The 7T spectra from subjects S3 and S9 were not included in the analysis due to movement artifacts in the data.</p>
</sec>
<sec sec-type="discussion" id="s4">
<title>Discussion</title>
<p>In our study, we tested the feasibility of MRI-PDFF assessment at 7T. Even-though MRS was considered for the &#x0201C;reference method&#x0201D; in hepatic fat content quantification, recent developments in MRI-PDFF at 3T have substantially improved the accuracy of the approach and made it the method of choice for hepatic fat content quantification [<xref ref-type="bibr" rid="B47">47</xref>, <xref ref-type="bibr" rid="B48">48</xref>] in clinical settings.</p>
<p>The results depicted in <xref ref-type="fig" rid="F2">Figure 2</xref> demonstrate an agreement between the MRI-PDFF distributions from 3T and 7T measurements in the investigated volumes. In most cases, the spectroscopic values were within the 25th and the 75th percentile of MRI-PDFF. In only one case was the MRS value not in this interval (<xref ref-type="fig" rid="F2">Figure 2</xref>), probably due to subtle motion of the subject between the MRS and MRI measurements. Another possible deteriorating effect is intra-voxel inhomogeneity, due to movement-related changes in local B<sub>0</sub>, which can lead to an improper estimation of PDFF. In 7T, MRI-DFF distributions show a larger range of values, and the number of outliers (red crosses, <xref ref-type="fig" rid="F2">Figure 2</xref>) is higher than at 3T. This can be caused by the inhomogeneity of <inline-formula><mml:math id="M6"><mml:msubsup><mml:mrow><mml:mtext>B</mml:mtext></mml:mrow><mml:mrow><mml:mn>1</mml:mn></mml:mrow><mml:mrow><mml:mo>-</mml:mo></mml:mrow></mml:msubsup></mml:math></inline-formula> over the FOV if the investigated volume is relatively distant from the coil surface, and hence, the water-fat separation process is more prone to errors due to lower SNR.</p>
<p>Correlation analyses confirm good agreement between MRI-PDFF 7T and 3T measurements in the investigated volumes. The level of agreement is attributable to measurement conditions, such as the measurement sequences (minimizing the acquisition time), patient measurement management (short time period between the 3T and 7T measurements&#x02013;not more than 1 h), and exhalation breath-hold. From our practical experience, the bias in BA-plots appears relatively low, given that we are comparing measurements at different magnetic field. Although initial preliminary studies concerning hepatic liver fat quantitation by MRI at 7T have already been published [<xref ref-type="bibr" rid="B64">64</xref>, <xref ref-type="bibr" rid="B65">65</xref>], in this study, a larger number of subjects was investigated, the distribution of MRI-PDFF in the investigated volumes was analyzed and compared to already established 7T MRS, and 3T MRI measurements were performed.</p>
<sec>
<title>Limitations</title>
<p>At the 7T, due to the unavailability of whole-body <sup>1</sup>H transmit RF hardware and B<sub>1</sub> shimming equipment, precise positioning of the multichannel Tx/Rx surface coil was necessary, and the quality of data and liver volume coverage also depended on the subject/patient body size and composition. In subjects with a low BMI, the liver volume coverage was sufficient and water-fat separation provided PDFF maps without water/fat swaps within the liver tissue. In subjects with a high BMI and body size, the PDFF maps were affected by water-fat swaps and determining the optimal parameters for the water-fat separation process was more complex. Nevertheless, the Graph-Cut approach applied here is flexible enough with regard to the input parameters (such as the regularization parameter, spatial subsampling for field map estimation, the range of field map, and many others), and, in many cases, a sufficient solution was found (i.e., the PDFF maps of liver cross-section or at least the VOI not affected by water/fat swaps). Furthermore, it is important to note that the use of ASPIRE for the combination of the multi-channel phase data ensured the correct input data for the used GC approach.</p>
<p>At this moment, PDFF-MRI at 7T with the phased-array Tx/Rx coil used does not provide satisfactory coverage of the whole liver for patients with a higher BMI (<xref ref-type="fig" rid="F1">Figure 1</xref>, <xref ref-type="supplementary-material" rid="SM1">Supplementary Materials 1</xref>, <xref ref-type="supplementary-material" rid="SM2">2</xref>), and does not provide any significant advantage over PDFF-MRI at 3T. The effective liver coverage is based on the patient body composition and the resulting electrical properties of a measured subject. We have to admit that the effective liver coverage dropping to 30% in some cases is a significant drawback of our 7T configuration compared to current 3T measurements where full liver coverage is not an issue, and that appears to be the main limitation of the study. The other potential limitations are minimal echo time and echo spacing, but in fact it can be a problem especially in approaches where are estimated individual fat components [<xref ref-type="bibr" rid="B66">66</xref>, <xref ref-type="bibr" rid="B67">67</xref>]. In our case, we have the prior knowledge of fat spectral model. However, there is strong potential to improve the quality of whole-liver imaging at 7T. Subjects with a high BMI frequently accompanied by oversized abdominal organs results in practical problems, such as B<sub>0</sub> shimming, RF power settings, and the coverage of the whole liver volume. The quality of 7T data could be improved using interactive <italic>B</italic><sub>1</sub> shimming [<xref ref-type="bibr" rid="B68">68</xref>, <xref ref-type="bibr" rid="B69">69</xref>], and liver coverage could be increased by the use of a volume body coil [<xref ref-type="bibr" rid="B70">70</xref>] in combination with an array coil [<xref ref-type="bibr" rid="B71">71</xref>], but neither of these was available for this study. Nevertheless, there are several possible pulse sequence options that may improve data quality in the future: Shorter echo spacing (use of shorter excitation pulses) and implementation of CAIPIRINHA acceleration can provide a significant reduction of acquisition time compared to GRAPPA, which was the only available parallel imaging option on our 7T system.</p>
</sec>
</sec>
<sec sec-type="conclusions" id="s5">
<title>Conclusion</title>
<p>Our results confirm the feasibility of hepatic fat content quantification by MRI-PDFF based on a multi-gradient-echo acquisition method at ultra-high field (7T) using a 32-channel Tx/Rx array coil. In addition to a coil configuration and other hardware equipment, the success of fat quantification using MRI-PDFF is based on the water-fat separation algorithm, including prior knowledge of the fat spectral model. In the presence of rapid field changes at 7T, a robust solution that avoids or at least minimizes water/fat swaps in the reconstructed MRI-PDFF maps (most importantly in the regions of interest) is required. The advanced coil configuration with the further envisioned hardware improvement will provide the opening for further improvement of whole-abdomen imaging and liver fat quantification for patients with a higher BMI.</p>
</sec>
<sec sec-type="data-availability-statement" id="s6">
<title>Data Availability Statement</title>
<p>The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.</p>
</sec>
<sec id="s7">
<title>Ethics Statement</title>
<p>The studies involving human participants were reviewed and approved by Ethics Committee, Medical University of Vienna. The patients/participants provided their written informed consent to participate in this study.</p>
</sec>
<sec id="s8">
<title>Author Contributions</title>
<p>RK and MKr&#x00161; designed the study, processed data, drafted the initial manuscript, reviewed and revised the manuscript, and coordinated and supervised data collection. RK, LP, HB, and MKre performed the measurements and ensured the patients for the study. KE and SR are responsible for ASPIRE reconstruction. MKr&#x00161;, ZS, ST, and SR critically reviewed the manuscript for important intellectual content. All authors approved the final manuscript as submitted and agree to be accountable for all aspects of the work.</p>
</sec>
<sec sec-type="COI-statement" id="conf1">
<title>Conflict of Interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
</body>
<back>
<sec sec-type="supplementary-material" id="s9">
<title>Supplementary Material</title>
<p>The Supplementary Material for this article can be found online at: <ext-link ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/fphy.2021.665562/full#supplementary-material">https://www.frontiersin.org/articles/10.3389/fphy.2021.665562/full#supplementary-material</ext-link></p>
<supplementary-material xlink:href="Data_Sheet_1.docx" id="SM1" mimetype="application/vnd.openxmlformats-officedocument.wordprocessingml.document" xmlns:xlink="http://www.w3.org/1999/xlink"/>
<supplementary-material xlink:href="Data_Sheet_2.docx" id="SM2" mimetype="application/vnd.openxmlformats-officedocument.wordprocessingml.document" xmlns:xlink="http://www.w3.org/1999/xlink"/>
<supplementary-material xlink:href="Data_Sheet_3.docx" id="SM3" mimetype="application/vnd.openxmlformats-officedocument.wordprocessingml.document" xmlns:xlink="http://www.w3.org/1999/xlink"/>
</sec>
<ref-list>
<title>References</title>
<ref id="B1">
<label>1.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Anderwald</surname> <given-names>C</given-names></name> <name><surname>Bernroider</surname> <given-names>E</given-names></name> <name><surname>Krssak</surname> <given-names>M</given-names></name> <name><surname>Stingl</surname> <given-names>H</given-names></name> <name><surname>Brehm</surname> <given-names>A</given-names></name> <name><surname>Bischof</surname> <given-names>MG</given-names></name> <etal/></person-group>. <article-title>Effects of insulin treatment in type 2 diabetic patients on intracellular lipid content in liver and skeletal muscle</article-title>. <source>Diabetes.</source> (<year>2002</year>) <volume>51</volume>:<fpage>3025</fpage>&#x02013;<lpage>32</lpage>. <pub-id pub-id-type="doi">10.2337/diabetes.51.10.3025</pub-id><pub-id pub-id-type="pmid">12351443</pub-id></citation></ref>
<ref id="B2">
<label>2.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Krssak</surname> <given-names>M</given-names></name> <name><surname>Falk</surname> <given-names>PK</given-names></name> <name><surname>Dresner</surname> <given-names>A</given-names></name> <name><surname>DiPietro</surname> <given-names>L</given-names></name> <name><surname>Vogel</surname> <given-names>SM</given-names></name> <name><surname>Rothman</surname> <given-names>DL</given-names></name> <etal/></person-group>. <article-title>Intramyocellular lipid concentrations are correlated with insulin sensitivity in humans: a 1H NMR spectroscopy study</article-title>. <source>Diabetologia.</source> (<year>1999</year>) <volume>42</volume>:<fpage>113</fpage>&#x02013;<lpage>6</lpage>. <pub-id pub-id-type="doi">10.1007/s001250051123</pub-id><pub-id pub-id-type="pmid">10027589</pub-id></citation></ref>
<ref id="B3">
<label>3.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Stepanova</surname> <given-names>M</given-names></name> <name><surname>Younossi</surname> <given-names>Z</given-names></name></person-group>. <article-title>Independent association between nonalcoholic fatty liver disease and cardiovascular disease in the US population</article-title>. <source>Clin Gastroenterol Hepatol.</source> (<year>2012</year>) <volume>10</volume>:<fpage>646</fpage>&#x02013;<lpage>50</lpage>. <pub-id pub-id-type="doi">10.1016/j.cgh.2011.12.039</pub-id><pub-id pub-id-type="pmid">22245962</pub-id></citation></ref>
<ref id="B4">
<label>4.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Seo</surname> <given-names>SW</given-names></name> <name><surname>Gottesman</surname> <given-names>RF</given-names></name> <name><surname>Clark</surname> <given-names>JM</given-names></name> <name><surname>Hernaez</surname> <given-names>R</given-names></name> <name><surname>Chang</surname> <given-names>Y</given-names></name> <name><surname>Kim</surname> <given-names>C</given-names></name> <etal/></person-group>. <article-title>Nonalcoholic fatty liver disease is associated with cognitive function in adults</article-title>. <source>Neurology.</source> (<year>2016</year>) <volume>86</volume>:<fpage>1136</fpage>&#x02013;<lpage>42</lpage>. <pub-id pub-id-type="doi">10.1212/WNL.0000000000002498</pub-id><pub-id pub-id-type="pmid">26911638</pub-id></citation></ref>
<ref id="B5">
<label>5.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Younossim</surname> <given-names>Z</given-names></name></person-group>. <article-title>Non-alcoholic fatty liver disease - a global public health perspective</article-title>. <source>J Hepatol.</source> (<year>2019</year>) <volume>70</volume>:<fpage>531</fpage>&#x02013;<lpage>44</lpage>. <pub-id pub-id-type="doi">10.1016/j.jhep.2018.10.033</pub-id><pub-id pub-id-type="pmid">30414863</pub-id></citation></ref>
<ref id="B6">
<label>6.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Reeder</surname> <given-names>S</given-names></name> <name><surname>Hu</surname> <given-names>H</given-names></name> <name><surname>Sirlin</surname> <given-names>C</given-names></name></person-group>. <article-title>Proton density fat-fraction: a standardized MR-based biomarker of tissue fat concentration</article-title>. <source>J Magn Reson Imaging.</source> (<year>2012</year>) <volume>36</volume>:<fpage>1011</fpage>&#x02013;<lpage>4</lpage>. <pub-id pub-id-type="doi">10.1002/jmri.23741</pub-id><pub-id pub-id-type="pmid">22777847</pub-id></citation></ref>
<ref id="B7">
<label>7.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Idilman</surname> <given-names>IS</given-names></name> <name><surname>Aniktar</surname> <given-names>H</given-names></name> <name><surname>Idilman</surname> <given-names>R</given-names></name> <name><surname>Kabacam</surname> <given-names>G</given-names></name> <name><surname>Savas</surname> <given-names>B</given-names></name> <name><surname>Elhan</surname> <given-names>A</given-names></name> <etal/></person-group>. <article-title>Hepatic steatosis: quantification by proton density fat fraction with MR imaging versus liver biopsy</article-title>. <source>Radiology.</source> (<year>2013</year>) <volume>267</volume>:<fpage>767</fpage>&#x02013;<lpage>75</lpage>. <pub-id pub-id-type="doi">10.1148/radiol.13121360</pub-id><pub-id pub-id-type="pmid">23382293</pub-id></citation></ref>
<ref id="B8">
<label>8.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yu</surname> <given-names>H</given-names></name> <name><surname>Shimakawa</surname> <given-names>A</given-names></name> <name><surname>McKenzie</surname> <given-names>C</given-names></name> <name><surname>Brodsky</surname> <given-names>E</given-names></name> <name><surname>Brittain</surname> <given-names>J</given-names></name> <name><surname>Reeder</surname> <given-names>S</given-names></name></person-group>. <article-title>Multiecho water-fat separation and simultaneous R2<sup>&#x0002A;</sup> estimation with multifrequency fat spectrum modeling</article-title>. <source>Magn Reson Med.</source> (<year>2008</year>) <volume>60</volume>:<fpage>1122</fpage>&#x02013;<lpage>34</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.21737</pub-id><pub-id pub-id-type="pmid">18956464</pub-id></citation></ref>
<ref id="B9">
<label>9.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tsao</surname> <given-names>J</given-names></name> <name><surname>Jiang</surname> <given-names>Y</given-names></name></person-group>. <article-title>Hierarchical IDEAL: fast, robust, and multiresolution separation of multiple chemical species from multiple echo times</article-title>. <source>Magn Reson Med.</source> (<year>2013</year>) <volume>70</volume>:<fpage>155</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.24441</pub-id><pub-id pub-id-type="pmid">22887356</pub-id></citation></ref>
<ref id="B10">
<label>10.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Reeder</surname> <given-names>S</given-names></name> <name><surname>Wen</surname> <given-names>Z</given-names></name> <name><surname>Yu</surname> <given-names>H</given-names></name> <name><surname>Pineda</surname> <given-names>AR</given-names></name> <name><surname>Gold</surname> <given-names>GE</given-names></name> <name><surname>Markl</surname> <given-names>M</given-names></name> <etal/></person-group>. <article-title>Multicoil dixon chemical species separation with an iterative least-squares estimation method</article-title>. <source>Magn Reson Med.</source> (<year>2004</year>) <volume>51</volume>:<fpage>35</fpage>&#x02013;<lpage>45</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.10675</pub-id><pub-id pub-id-type="pmid">14705043</pub-id></citation></ref>
<ref id="B11">
<label>11.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Glover</surname> <given-names>G</given-names></name></person-group>. <article-title>Multipoint dixon technique for water and fat proton and susceptibility imaging</article-title>. <source>J Magn Reson Imaging.</source> (<year>1991</year>) <volume>1</volume>:<fpage>521</fpage>&#x02013;<lpage>30</lpage>. <pub-id pub-id-type="doi">10.1002/jmri.1880010504</pub-id><pub-id pub-id-type="pmid">1790376</pub-id></citation></ref>
<ref id="B12">
<label>12.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yu</surname> <given-names>H</given-names></name> <name><surname>McKenzie</surname> <given-names>C</given-names></name> <name><surname>Shimakawa</surname> <given-names>A</given-names></name> <name><surname>Vu</surname> <given-names>AT</given-names></name> <name><surname>Brau</surname> <given-names>AC</given-names></name> <name><surname>Beatty</surname> <given-names>PJ</given-names></name> <etal/></person-group>. <article-title>Multiecho reconstruction for simultaneous water-fat decomposition and T2<sup>&#x0002A;</sup> estimation</article-title>. <source>J Magn Reson Imaging.</source> (<year>2007</year>) <volume>26</volume>:<fpage>1153</fpage>&#x02013;<lpage>61</lpage>. <pub-id pub-id-type="doi">10.1002/jmri.21090</pub-id><pub-id pub-id-type="pmid">17896369</pub-id></citation></ref>
<ref id="B13">
<label>13.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yu</surname> <given-names>H</given-names></name> <name><surname>Shimakawa</surname> <given-names>A</given-names></name> <name><surname>Hines</surname> <given-names>CD</given-names></name> <name><surname>McKenzie</surname> <given-names>CA</given-names></name> <name><surname>Hamilton</surname> <given-names>G</given-names></name> <name><surname>Sirlin</surname> <given-names>CB</given-names></name> <etal/></person-group>. <article-title>Combination of complex-based and magnitude-based multiecho water-fat separation for accurate quantification of fat-fraction</article-title>. <source>Magn Reson Med.</source> (<year>2011</year>) <volume>66</volume>:<fpage>199</fpage>&#x02013;<lpage>206</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.22840</pub-id><pub-id pub-id-type="pmid">21695724</pub-id></citation></ref>
<ref id="B14">
<label>14.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dietrich</surname> <given-names>O</given-names></name> <name><surname>Raya</surname> <given-names>J</given-names></name> <name><surname>Reeder</surname> <given-names>S</given-names></name> <name><surname>Reiser</surname> <given-names>M</given-names></name> <name><surname>Schoenberg</surname> <given-names>S</given-names></name></person-group>. <article-title>Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters</article-title>. <source>J Magn Reson Imaging.</source> (<year>2007</year>) <volume>26</volume>:<fpage>375</fpage>&#x02013;<lpage>85</lpage>. <pub-id pub-id-type="doi">10.1002/jmri.20969</pub-id><pub-id pub-id-type="pmid">17622966</pub-id></citation></ref>
<ref id="B15">
<label>15.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Stockmann</surname> <given-names>J</given-names></name> <name><surname>Witzel</surname> <given-names>T</given-names></name> <name><surname>Keil</surname> <given-names>B</given-names></name> <name><surname>Polimeni</surname> <given-names>JR</given-names></name> <name><surname>Mareyam</surname> <given-names>A</given-names></name> <name><surname>LaPierre</surname> <given-names>C</given-names></name> <etal/></person-group>. <article-title>A 32-channel combined RF and B0 shim array for 3T brain imaging</article-title>. <source>Magn Reson Med.</source> (<year>2016</year>) <volume>75</volume>:<fpage>441</fpage>&#x02013;<lpage>51</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.25587</pub-id><pub-id pub-id-type="pmid">25689977</pub-id></citation></ref>
<ref id="B16">
<label>16.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Navarro de Lara</surname> <given-names>L</given-names></name> <name><surname>Windischberger</surname> <given-names>C</given-names></name> <name><surname>Kuehne</surname> <given-names>A</given-names></name> <name><surname>Woletz</surname> <given-names>M</given-names></name> <name><surname>Sieg</surname> <given-names>J</given-names></name> <name><surname>Bestmann</surname> <given-names>S</given-names></name> <etal/></person-group>. <article-title>A novel coil array for combined TMS/fMRI experiments at 3 T</article-title>. <source>Magn Reson Med.</source> (<year>2015</year>) <volume>74</volume>:<fpage>1492</fpage>&#x02013;<lpage>501</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.25535</pub-id><pub-id pub-id-type="pmid">25421603</pub-id></citation></ref>
<ref id="B17">
<label>17.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wen</surname> <given-names>H</given-names></name> <name><surname>Denison</surname> <given-names>T</given-names></name> <name><surname>Singerman</surname> <given-names>R</given-names></name> <name><surname>Balaban</surname> <given-names>R</given-names></name></person-group>. <article-title>The intrinsic signal-to-noise ratio in human cardiac imaging at 1.5, 3, and 4 T</article-title>. <source>J Magn Reson.</source> (<year>1997</year>) <volume>125</volume>:<fpage>65</fpage>&#x02013;<lpage>71</lpage>. <pub-id pub-id-type="doi">10.1006/jmre.1996.1072</pub-id><pub-id pub-id-type="pmid">9245361</pub-id></citation></ref>
<ref id="B18">
<label>18.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Vaughan</surname> <given-names>JT</given-names></name> <name><surname>Garwood</surname> <given-names>M</given-names></name> <name><surname>Collins</surname> <given-names>CM</given-names></name> <name><surname>Liu</surname> <given-names>W</given-names></name> <name><surname>DelaBarre</surname> <given-names>L</given-names></name> <name><surname>Adriany</surname> <given-names>G</given-names></name> <etal/></person-group>. <article-title>7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images</article-title>. <source>Magn Reson Med.</source> (<year>2001</year>) <volume>46</volume>:<fpage>24</fpage>&#x02013;<lpage>30</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.1156</pub-id><pub-id pub-id-type="pmid">11443707</pub-id></citation></ref>
<ref id="B19">
<label>19.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pohmann</surname> <given-names>R</given-names></name> <name><surname>Speck</surname> <given-names>O</given-names></name> <name><surname>Scheffler</surname> <given-names>K</given-names></name></person-group>. <article-title>Signal-to-noise ratio and MR tissue parameters in human brain imaging at 3, 7, and 9.4 tesla using current receive coil arrays</article-title>. <source>Magn Reson Med.</source> (<year>2016</year>) <volume>75</volume>:<fpage>801</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.25677</pub-id><pub-id pub-id-type="pmid">25820458</pub-id></citation></ref>
<ref id="B20">
<label>20.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Balchandani</surname> <given-names>P</given-names></name> <name><surname>Naidich</surname> <given-names>T</given-names></name></person-group>. <article-title>Ultra-High-Field MR Neuroimaging</article-title>. <source>AJNR Am J Neuroradiol.</source> (<year>2015</year>) <volume>36</volume>:<fpage>1204</fpage>&#x02013;<lpage>15</lpage>. <pub-id pub-id-type="doi">10.3174/ajnr.A4180</pub-id></citation></ref>
<ref id="B21">
<label>21.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Trattnig</surname> <given-names>S</given-names></name> <name><surname>Springer</surname> <given-names>E</given-names></name> <name><surname>Bogner</surname> <given-names>W</given-names></name> <name><surname>Hangel</surname> <given-names>G</given-names></name> <name><surname>Strasser</surname> <given-names>B</given-names></name> <name><surname>Dymerska</surname> <given-names>B</given-names></name> <etal/></person-group>. <article-title>Key clinical benefits of neuroimaging at 7T</article-title>. <source>Neuroimage.</source> (<year>2018</year>) <volume>168</volume>:<fpage>477</fpage>&#x02013;<lpage>89</lpage>. <pub-id pub-id-type="doi">10.1016/j.neuroimage.2016.11.031</pub-id><pub-id pub-id-type="pmid">27851995</pub-id></citation></ref>
<ref id="B22">
<label>22.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Trattnig</surname> <given-names>S</given-names></name> <name><surname>Zb&#x000FD;n</surname> <given-names>S</given-names></name> <name><surname>Schmitt</surname> <given-names>B</given-names></name> <name><surname>Friedrich</surname> <given-names>K</given-names></name> <name><surname>Juras</surname> <given-names>V</given-names></name> <name><surname>Szomolanyi</surname> <given-names>P</given-names></name> <etal/></person-group>. <article-title>Advanced MR methods at ultra-high field (7 Tesla) for clinical musculoskeletal applications</article-title>. <source>Eur Radiol.</source> (<year>2012</year>) <volume>22</volume>:<fpage>2338</fpage>&#x02013;<lpage>46</lpage>. <pub-id pub-id-type="doi">10.1007/s00330-012-2508-0</pub-id><pub-id pub-id-type="pmid">22688127</pub-id></citation></ref>
<ref id="B23">
<label>23.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Korinek</surname> <given-names>R</given-names></name> <name><surname>Bartusek</surname> <given-names>B</given-names></name> <name><surname>Starcuk</surname> <given-names>Z</given-names></name></person-group>. <article-title>Water-Fat separation in rat by MRI at high field (9.4T)</article-title>. In: Measurement 2015 Proceedings of the 10th International Conference on Measurement. Smolenice (<year>2015</year>). p. <fpage>133</fpage>&#x02013;<lpage>6</lpage>.</citation></ref>
<ref id="B24">
<label>24.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kickler</surname> <given-names>N</given-names></name> <name><surname>van der Zwaag</surname> <given-names>W</given-names></name> <name><surname>Mekle</surname> <given-names>R</given-names></name> <name><surname>Kober</surname> <given-names>T</given-names></name> <name><surname>Marques</surname> <given-names>JP</given-names></name> <name><surname>Krueger</surname> <given-names>G</given-names></name> <etal/></person-group>. <article-title>Eddy current effects on a clinical 7T-68 cm bore scanner</article-title>. <source>MAGMA.</source> (<year>2010</year>) <volume>23</volume>:<fpage>39</fpage>&#x02013;<lpage>43</lpage>. <pub-id pub-id-type="doi">10.1007/s10334-009-0192-0</pub-id><pub-id pub-id-type="pmid">20012152</pub-id></citation></ref>
<ref id="B25">
<label>25.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>de Graaf</surname> <given-names>RA</given-names></name> <name><surname>Brown</surname> <given-names>PB</given-names></name> <name><surname>McIntyre</surname> <given-names>S</given-names></name> <name><surname>Nixon</surname> <given-names>TW</given-names></name> <name><surname>Behar</surname> <given-names>KL</given-names></name> <name><surname>Rothman</surname> <given-names>DL</given-names></name></person-group>. <article-title>High magnetic field water and metabolite proton T1 and T2 relaxation in rat brain <italic>in vivo</italic></article-title>. <source>Magn Reson Med</source>. (<year>2006</year>) <volume>56</volume>:<fpage>386</fpage>&#x02013;<lpage>94</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.20946</pub-id><pub-id pub-id-type="pmid">16767752</pub-id></citation></ref>
<ref id="B26">
<label>26.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gajdo&#x00161;&#x000ED;k</surname> <given-names>M</given-names></name> <name><surname>Chmel&#x000ED;k</surname> <given-names>M</given-names></name> <name><surname>Just-Kukurov&#x000E1;</surname> <given-names>I</given-names></name> <name><surname>Bogner</surname> <given-names>W</given-names></name> <name><surname>Valkovi&#x0010D;</surname> <given-names>L</given-names></name> <name><surname>Trattnig</surname> <given-names>S</given-names></name> <etal/></person-group>. <article-title>In vivo relaxation behavior of liver compounds at 7 Tesla, measured by single-voxel proton MR spectroscopy</article-title>. <source>J Magn Reson Imaging.</source> (<year>2014</year>) <volume>40</volume>:<fpage>1365</fpage>&#x02013;<lpage>74</lpage>. <pub-id pub-id-type="doi">10.1002/jmri.24489</pub-id><pub-id pub-id-type="pmid">24222653</pub-id></citation></ref>
<ref id="B27">
<label>27.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gajdo&#x00161;&#x000ED;k</surname> <given-names>M</given-names></name> <name><surname>Chadzynski</surname> <given-names>G</given-names></name> <name><surname>Hangel</surname> <given-names>G</given-names></name> <name><surname>Mlyn&#x000E1;rik</surname> <given-names>V</given-names></name> <name><surname>Chmel&#x000ED;k</surname> <given-names>M</given-names></name> <name><surname>Valkovi&#x0010D;</surname> <given-names>L</given-names></name> <etal/></person-group>. <article-title>Ultrashort-TE stimulated echo acquisition mode (STEAM) improves the quantification of lipids and fatty acid chain unsaturation in the human liver at 7 T</article-title>. <source>NMR Biomed.</source> (<year>2015</year>) <volume>28</volume>:<fpage>1283</fpage>&#x02013;<lpage>93</lpage>. <pub-id pub-id-type="doi">10.1002/nbm.3382</pub-id><pub-id pub-id-type="pmid">26313737</pub-id></citation></ref>
<ref id="B28">
<label>28.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hoult</surname> <given-names>D</given-names></name> <name><surname>Phil</surname> <given-names>D</given-names></name></person-group>. <article-title>Sensitivity and power deposition in a high-field imaging experiment</article-title>. <source>J Magn Reson Imaging.</source> (<year>2000</year>) <volume>12</volume>:<fpage>46</fpage>&#x02013;<lpage>67</lpage>. <pub-id pub-id-type="doi">10.1002/1522-2586(200007)12:1&#x0003C;46::AID-JMRI6&#x0003E;3.0.CO;2-D</pub-id><pub-id pub-id-type="pmid">10931564</pub-id></citation></ref>
<ref id="B29">
<label>29.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Collins</surname> <given-names>C</given-names></name> <name><surname>Wang</surname> <given-names>Z</given-names></name></person-group>. <article-title>Calculation of radiofrequency electromagnetic fields and their effects in MRI of human subjects</article-title>. <source>Magn Reson Med.</source> (<year>2011</year>) <volume>65</volume>:<fpage>1470</fpage>&#x02013;<lpage>82</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.22845</pub-id><pub-id pub-id-type="pmid">21381106</pub-id></citation></ref>
<ref id="B30">
<label>30.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hardy</surname> <given-names>CJ</given-names></name> <name><surname>Cline</surname> <given-names>HE</given-names></name> <name><surname>Giaquinto</surname> <given-names>RO</given-names></name> <name><surname>Niendorf</surname> <given-names>T</given-names></name> <name><surname>Grant</surname> <given-names>AK</given-names></name> <name><surname>Sodickson</surname> <given-names>DK</given-names></name></person-group>. <article-title>32-element receiver-coil array for cardiac imaging</article-title>. <source>Magn Reson Med</source>. (<year>2006</year>) <volume>55</volume>:<fpage>1142</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.20870</pub-id><pub-id pub-id-type="pmid">16596635</pub-id></citation></ref>
<ref id="B31">
<label>31.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Keil</surname> <given-names>B</given-names></name> <name><surname>Blau</surname> <given-names>JN</given-names></name> <name><surname>Biber</surname> <given-names>S</given-names></name> <name><surname>Hoecht</surname> <given-names>P</given-names></name> <name><surname>Tountcheva</surname> <given-names>V</given-names></name> <name><surname>Setsompop</surname> <given-names>K</given-names></name> <etal/></person-group>. <article-title>A 64-channel 3T array coil for accelerated brain MRI</article-title>. <source>Magn Reson Med.</source> (<year>2013</year>) <volume>70</volume>:<fpage>248</fpage>&#x02013;<lpage>58</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.24427</pub-id><pub-id pub-id-type="pmid">22851312</pub-id></citation></ref>
<ref id="B32">
<label>32.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhu</surname> <given-names>Y</given-names></name></person-group>. <article-title>Parallel excitation with an array of transmit coils</article-title>. <source>Magn Reson Med.</source> (<year>2004</year>) <volume>51</volume>:<fpage>775</fpage>&#x02013;<lpage>784</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.20011</pub-id><pub-id pub-id-type="pmid">15065251</pub-id></citation></ref>
<ref id="B33">
<label>33.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lattanzi</surname> <given-names>R</given-names></name> <name><surname>Sodickson</surname> <given-names>DK</given-names></name> <name><surname>Grant</surname> <given-names>AK</given-names></name> <name><surname>Zhu</surname> <given-names>Y</given-names></name></person-group>. <article-title>Electrodynamic constraints on homogeneity and radiofrequency power deposition in multiple coil excitations</article-title>. <source>Magn Reson Med.</source> (<year>2009</year>) <volume>61</volume>:<fpage>315</fpage>&#x02013;<lpage>334</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.21782</pub-id><pub-id pub-id-type="pmid">19165885</pub-id></citation></ref>
<ref id="B34">
<label>34.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhang</surname> <given-names>B</given-names></name> <name><surname>Seifert</surname> <given-names>AC</given-names></name> <name><surname>Kim</surname> <given-names>JW</given-names></name> <name><surname>Borrello</surname> <given-names>J</given-names></name> <name><surname>Xu</surname> <given-names>J</given-names></name></person-group>. <article-title>7 Tesla 22-channel wrap-around coil array for cervical spinal cord and brainstem imaging</article-title>. <source>Magn Reson Med</source>. (<year>2017</year>) <volume>78</volume>:<fpage>1623</fpage>&#x02013;<lpage>34</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.26538</pub-id></citation>
</ref>
<ref id="B35">
<label>35.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Rietsch</surname> <given-names>SHG</given-names></name> <name><surname>Orzada</surname> <given-names>S</given-names></name> <name><surname>Maderwald</surname> <given-names>S</given-names></name> <name><surname>Brunheim</surname> <given-names>S</given-names></name> <name><surname>Philips</surname> <given-names>BWJ</given-names></name> <name><surname>Scheenen</surname> <given-names>TWJ</given-names></name> <etal/></person-group>. <article-title>7T ultra-high field body MR imaging with an 8-channel transmit/32-channel receive radiofrequency coil array</article-title>. <source>Med Phys</source>. (<year>2018</year>) <volume>45</volume>:<fpage>2978</fpage>&#x02013;<lpage>90</lpage>. <pub-id pub-id-type="doi">10.1002/mp.12931</pub-id><pub-id pub-id-type="pmid">29679498</pub-id></citation></ref>
<ref id="B36">
<label>36.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dixon</surname> <given-names>W</given-names></name></person-group>. <article-title>Simple proton spectroscopic imaging</article-title>. <source>Radiology.</source> (<year>1984</year>) <volume>153</volume>:<fpage>189</fpage>&#x02013;<lpage>94</lpage>. <pub-id pub-id-type="doi">10.1148/radiology.153.1.6089263</pub-id></citation></ref>
<ref id="B37">
<label>37.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hernando</surname> <given-names>D</given-names></name> <name><surname>Kellman</surname> <given-names>P</given-names></name> <name><surname>Haldar</surname> <given-names>J</given-names></name> <name><surname>Liang</surname> <given-names>Z</given-names></name></person-group>. <article-title>Robust water/fat separation in the presence of large field inhomogeneities using a graph cut algorithm</article-title>. <source>Magn Reson Med.</source> (<year>2010</year>) <volume>63</volume>:<fpage>79</fpage>&#x02013;<lpage>90</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.22177</pub-id><pub-id pub-id-type="pmid">19859956</pub-id></citation></ref>
<ref id="B38">
<label>38.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sharma</surname> <given-names>SD</given-names></name> <name><surname>Hu</surname> <given-names>HH</given-names></name> <name><surname>Nayak</surname> <given-names>KS</given-names></name></person-group>. <article-title>Accelerated water-fat imaging using restricted subspace field map estimation and compressed sensing</article-title>. <source>Magn Reson Med.</source> (<year>2012</year>) <volume>67</volume>:<fpage>650</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.23052</pub-id><pub-id pub-id-type="pmid">21713983</pub-id></citation></ref>
<ref id="B39">
<label>39.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ren</surname> <given-names>J</given-names></name> <name><surname>Dimitrov</surname> <given-names>I</given-names></name> <name><surname>Sherry</surname> <given-names>AD</given-names></name> <name><surname>Malloy</surname> <given-names>CR</given-names></name></person-group>. <article-title>Composition of adipose tissue and marrow fat in humans by 1H NMR at 7 tesla</article-title>. <source>J Lipid Res.</source> (<year>2008</year>) <volume>49</volume>:<fpage>2055</fpage>&#x02013;<lpage>62</lpage>. <pub-id pub-id-type="doi">10.1194/jlr.D800010-JLR200</pub-id><pub-id pub-id-type="pmid">18509197</pub-id></citation></ref>
<ref id="B40">
<label>40.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hamilton</surname> <given-names>G</given-names></name> <name><surname>Smith</surname> <given-names>DL</given-names></name> <name><surname>Bydder</surname> <given-names>M</given-names></name> <name><surname>Nayak</surname> <given-names>KS</given-names></name> <name><surname>Hu</surname> <given-names>HH</given-names></name></person-group>. <article-title>MR properties of brown and white adipose tissues</article-title>. <source>J Magn Reson Imaging.</source> (<year>2011</year>) <volume>34</volume>:<fpage>468</fpage>&#x02013;<lpage>73</lpage>. <pub-id pub-id-type="doi">10.1002/jmri.22623</pub-id><pub-id pub-id-type="pmid">21780237</pub-id></citation></ref>
<ref id="B41">
<label>41.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yu</surname> <given-names>H</given-names></name> <name><surname>Reeder</surname> <given-names>SB</given-names></name> <name><surname>Shimakawa</surname> <given-names>A</given-names></name> <name><surname>Brittain</surname> <given-names>JH</given-names></name> <name><surname>Pelc</surname> <given-names>NJ</given-names></name></person-group>. <article-title>Field map estimation with a region growing scheme for iterative 3-point water-fat decomposition</article-title>. <source>Magn Reson Med.</source> (<year>2005</year>) <volume>54</volume>:<fpage>1032</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.20654</pub-id><pub-id pub-id-type="pmid">16142718</pub-id></citation></ref>
<ref id="B42">
<label>42.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hussain</surname> <given-names>HK</given-names></name> <name><surname>Chenevert</surname> <given-names>TL</given-names></name> <name><surname>Londy</surname> <given-names>FJ</given-names></name> <name><surname>Gulani</surname> <given-names>V</given-names></name> <name><surname>Swanson</surname> <given-names>SD</given-names></name> <name><surname>McKenna</surname> <given-names>BJ</given-names></name> <etal/></person-group>. <article-title>Hepatic fat fraction: MR imaging for quantitative measurement and display&#x02013;early experience</article-title>. <source>Radiology.</source> (<year>2005</year>) <volume>237</volume>:<fpage>1048</fpage>&#x02013;<lpage>55</lpage>. <pub-id pub-id-type="doi">10.1148/radiol.2373041639</pub-id><pub-id pub-id-type="pmid">16237138</pub-id></citation></ref>
<ref id="B43">
<label>43.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bydder</surname> <given-names>M</given-names></name> <name><surname>Yokoo</surname> <given-names>T</given-names></name> <name><surname>Hamilton</surname> <given-names>G</given-names></name> <name><surname>Middleton</surname> <given-names>MS</given-names></name> <name><surname>Chavez</surname> <given-names>AD</given-names></name> <name><surname>Schwimmer</surname> <given-names>JB</given-names></name> <etal/></person-group>. <article-title>Relaxation effects in the quantification of fat using gradient echo imaging</article-title>. <source>Magn Reson Imaging.</source> (<year>2008</year>) <volume>26</volume>:<fpage>347</fpage>&#x02013;<lpage>59</lpage>. <pub-id pub-id-type="doi">10.1016/j.mri.2007.08.012</pub-id><pub-id pub-id-type="pmid">18093781</pub-id></citation></ref>
<ref id="B44">
<label>44.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Curtis</surname> <given-names>WA</given-names></name> <name><surname>Fraum</surname> <given-names>TJ</given-names></name> <name><surname>An</surname> <given-names>H</given-names></name> <name><surname>Chen</surname> <given-names>Y</given-names></name> <name><surname>Shetty</surname> <given-names>AS</given-names></name> <name><surname>Fowler</surname> <given-names>KJ</given-names></name></person-group>. <article-title>Quantitative MRI of diffuse liver disease: current applications and future directions</article-title>. <source>Radiology.</source> (<year>2019</year>) <volume>290</volume>:<fpage>23</fpage>&#x02013;<lpage>30</lpage>. <pub-id pub-id-type="doi">10.1148/radiol.2018172765</pub-id><pub-id pub-id-type="pmid">30511906</pub-id></citation></ref>
<ref id="B45">
<label>45.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gracien</surname> <given-names>RM</given-names></name> <name><surname>Maiworm</surname> <given-names>M</given-names></name> <name><surname>Br&#x000FC;che</surname> <given-names>N</given-names></name> <name><surname>Shrestha</surname> <given-names>M</given-names></name> <name><surname>N&#x000F6;th</surname> <given-names>U</given-names></name> <name><surname>Hattingen</surname> <given-names>E</given-names></name> <etal/></person-group>. <article-title>How stable is quantitative MRI? - Assessment of intra- and inter-scanner-model reproducibility using identical acquisition sequences and data analysis programs</article-title>. <source>Neuroimage.</source> (<year>2020</year>) <volume>207</volume>:<fpage>116364</fpage>. <pub-id pub-id-type="doi">10.1016/j.neuroimage.2019.116364</pub-id><pub-id pub-id-type="pmid">31740340</pub-id></citation></ref>
<ref id="B46">
<label>46.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Phal</surname> <given-names>PM</given-names></name> <name><surname>Usmanov</surname> <given-names>A</given-names></name> <name><surname>Nesbit</surname> <given-names>GM</given-names></name> <name><surname>Anderson</surname> <given-names>JC</given-names></name> <name><surname>Spencer</surname> <given-names>D</given-names></name> <name><surname>Wang</surname> <given-names>P</given-names></name> <etal/></person-group>. <article-title>Qualitative comparison of 3-T and 1.5-T MRI in the evaluation of epilepsy</article-title>. <source>AJR Am J Roentgenol.</source> (<year>2008</year>) <volume>191</volume>:<fpage>890</fpage>&#x02013;<lpage>5</lpage>. <pub-id pub-id-type="doi">10.2214/AJR.07.3933</pub-id><pub-id pub-id-type="pmid">18716125</pub-id></citation></ref>
<ref id="B47">
<label>47.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bohte</surname> <given-names>AE</given-names></name> <name><surname>van Werven</surname> <given-names>JR</given-names></name> <name><surname>Bipat</surname> <given-names>S</given-names></name> <name><surname>Stoker</surname> <given-names>J</given-names></name></person-group>. <article-title>The diagnostic accuracy of US, CT, MRI and 1H-MRS for the evaluation of hepatic steatosis compared with liver biopsy: a meta-analysis</article-title>. <source>Eur Radiol.</source> (<year>2011</year>) <volume>21</volume>:<fpage>87</fpage>&#x02013;<lpage>97</lpage>. <pub-id pub-id-type="doi">10.1007/s00330-010-1905-5</pub-id><pub-id pub-id-type="pmid">20680289</pub-id></citation></ref>
<ref id="B48">
<label>48.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kor&#x000ED;nek</surname> <given-names>R</given-names></name> <name><surname>Gajdo&#x00161;&#x000ED;k</surname> <given-names>M</given-names></name> <name><surname>Trattnig</surname> <given-names>S</given-names></name> <name><surname>Star&#x0010D;uk</surname> <given-names>Z</given-names> <suffix>Jr</suffix></name> <name><surname>Kr&#x00161;&#x00161;&#x000E1;k</surname> <given-names>M</given-names></name></person-group>. <article-title>Low-level fat fraction quantification at 3 T: comparative study of different tools for water-fat reconstruction and MR spectroscopy</article-title>. <source>MAGMA.</source> (<year>2020</year>) <volume>33</volume>:<fpage>455</fpage>&#x02013;<lpage>68</lpage>. <pub-id pub-id-type="doi">10.1007/s10334-020-00825-9</pub-id><pub-id pub-id-type="pmid">31980962</pub-id></citation></ref>
<ref id="B49">
<label>49.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Krss&#x000E1;k</surname> <given-names>M</given-names></name> <name><surname>Hofer</surname> <given-names>H</given-names></name> <name><surname>Wrba</surname> <given-names>F</given-names></name> <name><surname>Meyerspeer</surname> <given-names>M</given-names></name> <name><surname>Brehm</surname> <given-names>A</given-names></name> <name><surname>Lohninger</surname> <given-names>A</given-names></name> <etal/></person-group>. <article-title>Non-invasive assessment of hepatic fat accumulation in chronic hepatitis C by 1H magnetic resonance spectroscopy</article-title>. <source>Eur J Radiol.</source> (<year>2010</year>) <volume>74</volume>:<fpage>e60</fpage>&#x02013;<lpage>6</lpage>. <pub-id pub-id-type="doi">10.1016/j.ejrad.2009.03.062</pub-id><pub-id pub-id-type="pmid">19406596</pub-id></citation></ref>
<ref id="B50">
<label>50.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>H&#x000E1;jek</surname> <given-names>M</given-names></name> <name><surname>Dezortov&#x000E1;</surname> <given-names>M</given-names></name> <name><surname>Wagnerov&#x000E1;</surname> <given-names>D</given-names></name> <name><surname>Skoch</surname> <given-names>A</given-names></name> <name><surname>Voska</surname> <given-names>L</given-names></name> <name><surname>Hejlov&#x000E1;</surname> <given-names>I</given-names></name> <etal/></person-group>. <article-title>MR spectroscopy as a tool for <italic>in vivo</italic> determination of steatosis in liver transplant recipients</article-title>. <source>MAGMA.</source> (<year>2011</year>) <volume>24</volume>:<fpage>297</fpage>&#x02013;<lpage>304</lpage>. <pub-id pub-id-type="doi">10.1007/s10334-011-0264-9</pub-id><pub-id pub-id-type="pmid">21744232</pub-id></citation></ref>
<ref id="B51">
<label>51.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pfleger</surname> <given-names>L</given-names></name> <name><surname>Gajdo&#x00161;&#x000ED;k</surname> <given-names>M</given-names></name> <name><surname>Wolf</surname> <given-names>P</given-names></name> <name><surname>Smajis</surname> <given-names>S</given-names></name> <name><surname>Fellinger</surname> <given-names>P</given-names></name> <name><surname>Kuehne</surname> <given-names>A</given-names></name> <etal/></person-group>. <article-title>Absolute quantification of phosphor-containing metabolites in the liver using 31 P MRSI and hepatic lipid volume correction at 7T suggests no dependence on body mass index or age</article-title>. <source>J Magn Reson Imaging.</source> (<year>2019</year>) <volume>49</volume>:<fpage>597</fpage>&#x02013;<lpage>607</lpage>. <pub-id pub-id-type="doi">10.1002/jmri.26225</pub-id></citation>
</ref>
<ref id="B52">
<label>52.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wolf</surname> <given-names>P</given-names></name> <name><surname>Fellinger</surname> <given-names>P</given-names></name> <name><surname>Pfleger</surname> <given-names>L</given-names></name> <name><surname>Smajis</surname> <given-names>S</given-names></name> <name><surname>Beiglb&#x000F6;ck</surname> <given-names>H</given-names></name> <name><surname>Gajdo&#x00161;&#x000ED;k</surname> <given-names>M</given-names></name> <etal/></person-group>. <article-title>Reduced hepatocellular lipid accumulation and energy metabolism in patients with long standing type 1 diabetes mellitus</article-title>. <source>Sci Rep.</source> (<year>2019</year>) <volume>9</volume>:<fpage>2576</fpage>. <pub-id pub-id-type="doi">10.1038/s41598-019-39362-4</pub-id><pub-id pub-id-type="pmid">30796305</pub-id></citation></ref>
<ref id="B53">
<label>53.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Smajis</surname> <given-names>S</given-names></name> <name><surname>Gajdo&#x00161;&#x000ED;k</surname> <given-names>M</given-names></name> <name><surname>Pfleger</surname> <given-names>L</given-names></name> <name><surname>Traussnigg</surname> <given-names>S</given-names></name> <name><surname>Kienbacher</surname> <given-names>C</given-names></name> <name><surname>Halilbasic</surname> <given-names>E</given-names></name> <etal/></person-group>. <article-title>Metabolic effects of a prolonged, very-high-dose dietary fructose challenge in healthy subjects</article-title>. <source>Am J Clin Nutr.</source> (<year>2020</year>) <volume>9</volume>:<fpage>369</fpage>&#x02013;<lpage>77</lpage>. <pub-id pub-id-type="doi">10.1093/ajcn/nqz271</pub-id><pub-id pub-id-type="pmid">32016353</pub-id></citation></ref>
<ref id="B54">
<label>54.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Griswold</surname> <given-names>MA</given-names></name> <name><surname>Jakob</surname> <given-names>PM</given-names></name> <name><surname>Heidemann</surname> <given-names>RM</given-names></name> <name><surname>Nittka</surname> <given-names>M</given-names></name> <name><surname>Jellus</surname> <given-names>V</given-names></name> <name><surname>Wang</surname> <given-names>J</given-names></name> <etal/></person-group>. <article-title>Generalized autocalibrating partially parallel acquisitions (GRAPPA)</article-title>. <source>Magn Reson Med.</source> (<year>2002</year>) <volume>47</volume>:<fpage>1202</fpage>&#x02013;<lpage>10</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.10171</pub-id><pub-id pub-id-type="pmid">18219627</pub-id></citation></ref>
<ref id="B55">
<label>55.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Eckstein</surname> <given-names>K</given-names></name> <name><surname>Dymerska</surname> <given-names>B</given-names></name> <name><surname>Bachrata</surname> <given-names>B</given-names></name> <name><surname>Bogner</surname> <given-names>W</given-names></name> <name><surname>Poljanc</surname> <given-names>K</given-names></name> <name><surname>Trattnig</surname> <given-names>S</given-names></name> <etal/></person-group>. <article-title>Computationally efficient combination of multi-channel phase data from multi-echo acquisitions (ASPIRE)</article-title>. <source>Magn Reson Med.</source> (<year>2018</year>) <volume>79</volume>:<fpage>2996</fpage>&#x02013;<lpage>3006</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.26963</pub-id><pub-id pub-id-type="pmid">29034511</pub-id></citation></ref>
<ref id="B56">
<label>56.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hu</surname> <given-names>HH</given-names></name> <name><surname>Bornert</surname> <given-names>P</given-names></name> <name><surname>Hernando</surname> <given-names>D</given-names></name> <name><surname>Kellman</surname> <given-names>P</given-names></name> <name><surname>Ma</surname> <given-names>J</given-names></name> <name><surname>Reeder</surname> <given-names>S</given-names></name> <etal/></person-group>. <article-title>ISMRM workshop on fat-water separation: insights, applications and progress in MRI</article-title>. <source>Magn Reson Med.</source> (<year>2012</year>) <volume>68</volume>:<fpage>378</fpage>&#x02013;<lpage>88</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.24369</pub-id><pub-id pub-id-type="pmid">22693111</pub-id></citation></ref>
<ref id="B57">
<label>57.</label>
<citation citation-type="web"><person-group person-group-type="author"><collab>WaterFat12 ISMRM toolbox</collab></person-group>. (<year>2012</year>). Available online at: <ext-link ext-link-type="uri" xlink:href="https://www.ismrm.org/workshops/FatWater12/data.htm">https://www.ismrm.org/workshops/FatWater12/data.htm</ext-link></citation></ref>
<ref id="B58">
<label>58.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Naressi</surname> <given-names>A</given-names></name> <name><surname>Couturier</surname> <given-names>C</given-names></name> <name><surname>Devos</surname> <given-names>JM</given-names></name> <name><surname>Janssen</surname> <given-names>M</given-names></name> <name><surname>Mangeat</surname> <given-names>C</given-names></name> <name><surname>de Beer</surname> <given-names>R</given-names></name> <etal/></person-group>. <article-title>Java-based graphical user interface for the MRUI quantitation package</article-title>. <source>MAGMA.</source> (<year>2001</year>) <volume>12</volume>:<fpage>141</fpage>&#x02013;<lpage>52</lpage>. <pub-id pub-id-type="doi">10.1007/BF02668096</pub-id><pub-id pub-id-type="pmid">11390270</pub-id></citation></ref>
<ref id="B59">
<label>59.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Vanhamme</surname> <given-names>L</given-names></name> <name><surname>van den Boogaart</surname> <given-names>A</given-names></name> <name><surname>Van Huffel</surname> <given-names>S</given-names></name></person-group>. <article-title>Improved method for accurate and efficient quantification of MRS data with use of prior knowledge</article-title>. <source>J Magn Reson.</source> (<year>1997</year>) <volume>129</volume>:<fpage>35</fpage>&#x02013;<lpage>43</lpage>. <pub-id pub-id-type="doi">10.1006/jmre.1997.1244</pub-id><pub-id pub-id-type="pmid">9405214</pub-id></citation></ref>
<ref id="B60">
<label>60.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Graveron-Demilly</surname> <given-names>D</given-names></name></person-group>. <article-title>Quantification in magnetic resonance spectroscopy based on semi-parametric approaches</article-title>. <source>MAGMA.</source> (<year>2014</year>) <volume>27</volume>:<fpage>113</fpage>&#x02013;<lpage>30</lpage>. <pub-id pub-id-type="doi">10.1007/s10334-013-0393-4</pub-id><pub-id pub-id-type="pmid">23892473</pub-id></citation></ref>
<ref id="B61">
<label>61.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Haase</surname> <given-names>A</given-names></name> <name><surname>Frahm</surname> <given-names>J</given-names></name> <name><surname>Matthaei</surname> <given-names>K</given-names></name></person-group>. <article-title>FLASH imaging: rapid NMR imaging using low flip angle pulses</article-title>. <source>J Magn Reson.</source> (<year>1986</year>) <volume>67</volume>:<fpage>258</fpage>&#x02013;<lpage>66</lpage>. <pub-id pub-id-type="doi">10.1016/0022-2364(86)90433-6</pub-id><pub-id pub-id-type="pmid">22152368</pub-id></citation></ref>
<ref id="B62">
<label>62.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Breuer</surname> <given-names>FA</given-names></name> <name><surname>Blaimer</surname> <given-names>M</given-names></name> <name><surname>Heidemann</surname> <given-names>RM</given-names></name> <name><surname>Mueller</surname> <given-names>MF</given-names></name> <name><surname>Griswold</surname> <given-names>MA</given-names></name> <name><surname>Jakob</surname> <given-names>PM</given-names></name></person-group>. <article-title>Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging</article-title>. <source>Magn Reson Med.</source> (<year>2005</year>) <volume>53</volume>:<fpage>684</fpage>&#x02013;<lpage>91</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.20401</pub-id><pub-id pub-id-type="pmid">15723404</pub-id></citation></ref>
<ref id="B63">
<label>63.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Breuer</surname> <given-names>FA</given-names></name> <name><surname>Blaimer</surname> <given-names>M</given-names></name> <name><surname>Mueller</surname> <given-names>MF</given-names></name> <name><surname>Seiberlich</surname> <given-names>N</given-names></name> <name><surname>Heidemann</surname> <given-names>RM</given-names></name> <name><surname>Griswold</surname> <given-names>MA</given-names></name> <etal/></person-group>. <article-title>Controlled aliasing in volumetric parallel imaging (2D CAIPIRINHA)</article-title>. <source>Magn Reson Med.</source> (<year>2006</year>) <volume>55</volume>:<fpage>549</fpage>&#x02013;<lpage>56</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.20787</pub-id><pub-id pub-id-type="pmid">16408271</pub-id></citation></ref>
<ref id="B64">
<label>64.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kor&#x000ED;nek</surname> <given-names>R</given-names></name> <name><surname>Eckstein</surname> <given-names>K</given-names></name> <name><surname>Stra&#x0010D;uk</surname> <given-names>Z</given-names> <suffix>Jr</suffix></name> <name><surname>Trattnig</surname> <given-names>S</given-names></name> <name><surname>Kr&#x00161;&#x00161;&#x000E1;k</surname> <given-names>M</given-names></name></person-group>. <article-title>Feasibility of abdominal quantitative imaging at 7T: pilot study</article-title>. In: <source>Proceeding International Society Magnetic Resonance Medicine</source>. Montreal, QC (<year>2019</year>).</citation></ref>
<ref id="B65">
<label>65.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Williams</surname> <given-names>H</given-names></name> <name><surname>Doran</surname> <given-names>E</given-names></name> <name><surname>Bawden</surname> <given-names>S</given-names></name> <name><surname>Mirfin</surname> <given-names>C</given-names></name> <name><surname>Gowland</surname> <given-names>P</given-names></name></person-group>. <article-title>Liver mDixon at 7T</article-title>. In: <source>Proceeding International Society Magnetic Resonance Medicine</source>. Montreal, QC (<year>2019</year>).</citation></ref>
<ref id="B66">
<label>66.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Leporq</surname> <given-names>B</given-names></name> <name><surname>Lambert</surname> <given-names>SA</given-names></name> <name><surname>Ronot</surname> <given-names>M</given-names></name> <name><surname>Boucenna</surname> <given-names>I</given-names></name> <name><surname>Colinart</surname> <given-names>P</given-names></name> <name><surname>Cauchy</surname> <given-names>F</given-names></name> <etal/></person-group>. <article-title>Hepatic fat fraction and visceral adipose tissue fatty acid composition in mice: quantification with 7.0T MRI</article-title>. <source>Magn Reson Med.</source> (<year>2016</year>) <volume>76</volume>:<fpage>510</fpage>&#x02013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.25895</pub-id><pub-id pub-id-type="pmid">26527483</pub-id></citation></ref>
<ref id="B67">
<label>67.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Berglund</surname> <given-names>J</given-names></name> <name><surname>Ahlstr&#x000F6;m</surname> <given-names>H</given-names></name> <name><surname>Kullberg</surname> <given-names>J</given-names></name></person-group>. <article-title>Model-based mapping of fat unsaturation and chain length by chemical shift imaging&#x02013;phantom validation and <italic>in vivo</italic> feasibility</article-title>. <source>Magn Reson Med.</source> (<year>2012</year>) <volume>68</volume>:<fpage>1815</fpage>&#x02013;<lpage>27</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.24196</pub-id><pub-id pub-id-type="pmid">22334300</pub-id></citation></ref>
<ref id="B68">
<label>68.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Metzger</surname> <given-names>GJ</given-names></name> <name><surname>Auerbach</surname> <given-names>EJ</given-names></name> <name><surname>Akgun</surname> <given-names>C</given-names></name> <name><surname>Simonson</surname> <given-names>J</given-names></name> <name><surname>Bi</surname> <given-names>X</given-names></name> <name><surname>Ugurbil</surname> <given-names>K</given-names></name> <etal/></person-group>. <article-title>Dynamically applied B1&#x0002B; shimming solutions for non-contrast enhanced renal angiography at 7.0 Tesla</article-title>. <source>Magn Reson Med.</source> (<year>2013</year>) <volume>69</volume>:<fpage>114</fpage>&#x02013;<lpage>26</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.24237</pub-id><pub-id pub-id-type="pmid">22442056</pub-id></citation></ref>
<ref id="B69">
<label>69.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Damen</surname> <given-names>M</given-names></name> <name><surname>van Houtum</surname> <given-names>Q</given-names></name> <name><surname>van Leeuwen</surname> <given-names>M</given-names></name> <name><surname>Luijten</surname> <given-names>P</given-names></name> <name><surname>Webb</surname> <given-names>A</given-names></name> <name><surname>Klomp</surname></name> <etal/></person-group>. <article-title>Quantitative T1 and T2 measurements of pancreas at 7 Tesla using a multi-transmit system</article-title>. In: <source>Proceeding International Society Magnetic Resonance Medicine</source> (Honolulu, HI) (<year>2017</year>).</citation></ref>
<ref id="B70">
<label>70.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Vaughan</surname> <given-names>JT</given-names></name> <name><surname>Snyder</surname> <given-names>CJ</given-names></name> <name><surname>DelaBarre</surname> <given-names>LJ</given-names></name> <name><surname>Bolan</surname> <given-names>PJ</given-names></name> <name><surname>Tian</surname> <given-names>J</given-names></name> <name><surname>Bolinger</surname> <given-names>L</given-names></name> <etal/></person-group>. <article-title>Whole-body imaging at 7T: preliminary results</article-title>. <source>Magn Reson Med.</source> (<year>2009</year>) <volume>61</volume>:<fpage>244</fpage>&#x02013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.21751</pub-id><pub-id pub-id-type="pmid">19097214</pub-id></citation></ref>
<ref id="B71">
<label>71.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Vaughan</surname> <given-names>J</given-names></name> <name><surname>Snyder</surname> <given-names>C</given-names></name> <name><surname>Delabarre</surname> <given-names>L</given-names></name> <name><surname>Tian</surname> <given-names>J</given-names></name> <name><surname>Adriany</surname> <given-names>G</given-names></name> <name><surname>Andersen</surname> <given-names>P</given-names></name> <etal/></person-group>. <article-title>Clinical imaging at 7T with a 16 channel whole body coil and 32 receive channels</article-title>. In: <source>Proceeding International Society Magnetic Resonance Medicine</source>. Honolulu (<year>2009</year>).</citation></ref>
</ref-list>
<fn-group>
<fn fn-type="financial-disclosure"><p><bold>Funding.</bold> This work was partially supported by the European Commission and the Ministry of Education, Youth, and Sports of the Czech Republic (projects Nos. CZ.02.1.01/0.0/0.0/16_013/0001775, LM2018129; 7AMB18AT023; 8J18AT023; AKTION AUT-CZE &#x00023; 74p6), the Czech Academy of Sciences (project No. MSM100651801), Austrian Federal Ministry of Education, Science and Research; Contract Grant No. BMWFW WTZ Mobility, CZ09-2019 and the Austrian Science Fund FWF31452. SR was also supported by the Marie Sk&#x00142;odowska-Curie Action MS-fMRI-QSM 794298.</p>
</fn>
</fn-group>
</back>
</article>