<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Phys.</journal-id>
<journal-title>Frontiers in Physics</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Phys.</abbrev-journal-title>
<issn pub-type="epub">2296-424X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fphy.2017.00022</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Physics</subject>
<subj-group>
<subject>Technology Report</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Myocardial <italic>T</italic><sub>2</sub><sup>&#x0002A;</sup> Mapping with Ultrahigh Field Magnetic Resonance: Physics and Frontier Applications</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name><surname>Huelnhagen</surname> <given-names>Till</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/269312/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Paul</surname> <given-names>Katharina</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/432575/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Ku</surname> <given-names>Min-Chi</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/251841/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Serradas Duarte</surname> <given-names>Teresa</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name><surname>Niendorf</surname> <given-names>Thoralf</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<xref ref-type="author-notes" rid="fn001"><sup>&#x0002A;</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/269619/overview"/>
</contrib>
</contrib-group>
<aff id="aff1"><sup>1</sup><institution>Berlin Ultrahigh Field Facility, Max Delbr&#x000FC;ck Center for Molecular Medicine in the Helmholtz Association</institution> <country>Berlin, Germany</country></aff>
<aff id="aff2"><sup>2</sup><institution>DZHK (German Centre for Cardiovascular Research)</institution> <country>Berlin, Germany</country></aff>
<aff id="aff3"><sup>3</sup><institution>MRI.TOOLS GmbH</institution> <country>Berlin, Germany</country></aff>
<author-notes>
<fn fn-type="edited-by"><p>Edited by: Ewald Moser, Medical University of Vienna, Austria</p></fn>
<fn fn-type="edited-by"><p>Reviewed by: Bernhard Gruber, University Medical Center Utrecht, Netherlands; Albrecht Ingo Schmid, Medical University of Vienna, Austria</p></fn>
<fn fn-type="corresp" id="fn001"><p>&#x0002A;Correspondence: Thoralf Niendorf <email>thoralf.niendorf&#x00040;mdc-berlin.de</email></p></fn>
<fn fn-type="other" id="fn002"><p>This article was submitted to Biomedical Physics, a section of the journal Frontiers in Physics</p></fn></author-notes>
<pub-date pub-type="epub">
<day>14</day>
<month>06</month>
<year>2017</year>
</pub-date>
<pub-date pub-type="collection">
<year>2017</year>
</pub-date>
<volume>5</volume>
<elocation-id>22</elocation-id>
<history>
<date date-type="received">
<day>24</day>
<month>03</month>
<year>2017</year>
</date>
<date date-type="accepted">
<day>30</day>
<month>05</month>
<year>2017</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x000A9; 2017 Huelnhagen, Paul, Ku, Serradas Duarte and Niendorf.</copyright-statement>
<copyright-year>2017</copyright-year>
<copyright-holder>Huelnhagen, Paul, Ku, Serradas Duarte and Niendorf</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license>
</permissions>
<abstract><p>Cardiovascular magnetic resonance imaging (CMR) has become an indispensable clinical tool for the assessment of morphology, function and structure of the heart muscle. By exploiting quantification of the effective transverse relaxation time (<inline-formula><mml:math id="M2"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>) CMR also affords myocardial tissue characterization and probing of cardiac physiology, both being in the focus of ongoing research. These developments are fueled by the move to ultrahigh magnetic field strengths, which permits enhanced sensitivity and spatial resolution that help to overcome limitations of current clinical MR systems with the goal to contribute to a better understanding of myocardial (patho)physiology <italic>in vivo</italic>. In this context, the aim of this report is to introduce myocardial <inline-formula><mml:math id="M3"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping at ultrahigh magnetic fields as a promising technique to non-invasively assess myocardial (patho)physiology. For this purpose the basic principles of <inline-formula><mml:math id="M4"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> assessment, the biophysical mechanisms determining <inline-formula><mml:math id="M5"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> and (pre)clinical applications of myocardial <inline-formula><mml:math id="M6"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping are presented. Technological challenges and solutions for <inline-formula><mml:math id="M7"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> sensitized CMR at ultrahigh magnetic field strengths are discussed followed by a review of acquisition techniques and post-processing approaches. Preliminary results derived from myocardial <inline-formula><mml:math id="M8"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping in healthy subjects and cardiac patients at 7.0 T are presented. A concluding section discusses remaining questions and challenges and provides an outlook on future developments and potential clinical applications.</p></abstract>
<kwd-group>
<kwd>magnetic resonance</kwd>
<kwd>MRI</kwd>
<kwd>ultrahigh field</kwd>
<kwd>magnetic susceptibility</kwd>
<kwd>MR technology</kwd>
<kwd>cardiac physiology</kwd>
<kwd>cardiovascular imaging</kwd>
<kwd>myocardial tissue characterization</kwd>
</kwd-group>
<contract-num rid="cn001">BER 601</contract-num>
<contract-num rid="cn002">FKZ 81Z6100161</contract-num>
<contract-num rid="cn002">FKZ 01QE1501B</contract-num>
<contract-num rid="cn003">E! 9340 hearRT-4-EU</contract-num>
<contract-sponsor id="cn001">Deutsches Zentrum f&#x000FC;r Herz-Kreislaufforschung<named-content content-type="fundref-id">10.13039/100010447</named-content></contract-sponsor>
<contract-sponsor id="cn002">Bundesministerium f&#x000FC;r Bildung und Forschun<named-content content-type="fundref-id">10.13039/501100002347</named-content></contract-sponsor>
<contract-sponsor id="cn003">Horizon 2020 Framework Programme<named-content content-type="fundref-id">10.13039/100010661</named-content></contract-sponsor>
<counts>
<fig-count count="13"/>
<table-count count="0"/>
<equation-count count="11"/>
<ref-count count="123"/>
<page-count count="19"/>
<word-count count="13118"/>
</counts>
</article-meta>
</front>
<body>
<sec sec-type="intro" id="s1">
<title>Introduction</title>
<sec>
<title><inline-formula><mml:math id="M9"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> sensitized cardiovascular magnetic resonance</title>
<p>Myocardial tissue characterization plays an important role in the diagnosis and treatment of cardiac diseases. Thanks to its soft tissue contrast and versatility, cardiovascular magnetic resonance imaging (CMR) has become a vital clinical tool for diagnosis and for guiding therapy of cardiac diseases [<xref ref-type="bibr" rid="B1">1</xref>, <xref ref-type="bibr" rid="B2">2</xref>]. CMR can provide morphologic and functional information as well as insights into microstructural changes of the heart muscle [<xref ref-type="bibr" rid="B2">2</xref>]. Quantitative mapping of MR relaxation times which govern the MR signal evolution offers the potential of non-invasive myocardial tissue characterization without the need of exogenous contrast agents. Mapping of the effective transverse relaxation time <inline-formula><mml:math id="M10"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> is the subject of intense clinical interest in CMR. By exploiting the blood oxygenation level-dependent (BOLD) effect [<xref ref-type="bibr" rid="B3">3</xref>], <inline-formula><mml:math id="M11"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> sensitized CMR has been proposed as a means of assessing myocardial tissue oxygenation and perfusion. <inline-formula><mml:math id="M12"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping has been shown to be capable of detecting myocardial ischemia caused by coronary artery stenosis [<xref ref-type="bibr" rid="B4">4</xref>], to reveal myocardial perfusion deficits under pharmacological stress [<xref ref-type="bibr" rid="B5">5</xref>&#x02013;<xref ref-type="bibr" rid="B10">10</xref>], to study endothelial function [<xref ref-type="bibr" rid="B11">11</xref>] or to assess breathing maneuver-dependent oxygenation changes in the myocardium [<xref ref-type="bibr" rid="B12">12</xref>&#x02013;<xref ref-type="bibr" rid="B15">15</xref>]. Preclinical studies have also demonstrated the potential of <inline-formula><mml:math id="M13"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping to detect structural changes in the infarcted heart muscle and even to distinguish between focal and diffuse fibrosis [<xref ref-type="bibr" rid="B16">16</xref>&#x02013;<xref ref-type="bibr" rid="B18">18</xref>]. In clinical application <inline-formula><mml:math id="M14"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping is the method of choice for quantification of myocardial iron content, an essential parameter for guiding therapy in patients with myocardial iron overload [<xref ref-type="bibr" rid="B19">19</xref>&#x02013;<xref ref-type="bibr" rid="B23">23</xref>].</p>
<p>The linear increase of susceptibility effects with magnetic field strength together with the availability of ultrahigh field (<italic>B</italic><sub>0</sub> &#x02265; 7.0 T) whole body human MR systems has fueled explorations into myocardial <inline-formula><mml:math id="M15"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping at 7.0 T. In this context, the aim of this report is to introduce the biophysical background of <inline-formula><mml:math id="M16"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> as a promising MR biomarker, present challenges and technical solutions for myocardial <inline-formula><mml:math id="M17"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> assessment at ultrahigh magnetic field strengths, discuss its merits and current limitations, as well as to show early applications in healthy volunteers and cardiac patients along with providing a look beyond the horizon.</p>
</sec>
<sec>
<title>Biophysics of the effective transverse relaxation time <inline-formula><mml:math id="M18"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula></title>
<p>The fundamental principle behind <inline-formula><mml:math id="M19"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> relaxation is the loss of phase coherence of an ensemble of spins contained within a volume of interest or voxel after a radio frequency (RF) excitation. Unlike <italic>T</italic><sub>1</sub> relaxation which is based on spin-lattice interactions or <italic>T</italic><sub>2</sub> relaxation which is caused by spin-spin interactions both being inherent properties of tissues in a magnetic field, <inline-formula><mml:math id="M20"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> relaxation includes a tissue inherent part as well as contributions from external magnetic field perturbations [<xref ref-type="bibr" rid="B24">24</xref>]. These magnetic field inhomogeneities influence the effective transversal MR relaxation time <inline-formula><mml:math id="M21"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> [<xref ref-type="bibr" rid="B25">25</xref>, <xref ref-type="bibr" rid="B26">26</xref>]. <inline-formula><mml:math id="M22"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> is defined as:</p>
<disp-formula id="E1"><label>(1)</label><mml:math id="M23"><mml:mrow><mml:mfrac><mml:mn>1</mml:mn><mml:mrow><mml:msubsup><mml:mi>T</mml:mi><mml:mn>2</mml:mn><mml:mo>&#x02217;</mml:mo></mml:msubsup></mml:mrow></mml:mfrac><mml:mtext>&#x02009;</mml:mtext><mml:mo>=</mml:mo><mml:mtext>&#x02009;</mml:mtext><mml:mfrac><mml:mn>1</mml:mn><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow></mml:mfrac><mml:mtext>&#x02009;</mml:mtext><mml:mo>+</mml:mo><mml:mtext>&#x02009;</mml:mtext><mml:mfrac><mml:mn>1</mml:mn><mml:mrow><mml:msub><mml:msup><mml:mi>T</mml:mi><mml:mo>&#x02032;</mml:mo></mml:msup><mml:mn>2</mml:mn></mml:msub></mml:mrow></mml:mfrac><mml:mtext>&#x02009;</mml:mtext></mml:mrow></mml:math></disp-formula>
<p>with <italic>T</italic><sub>2</sub> being the transverse relaxation time and <inline-formula><mml:math id="M24"><mml:msubsup><mml:mrow><mml:mi>T</mml:mi></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow><mml:mrow><mml:mi>&#x02032;</mml:mi></mml:mrow></mml:msubsup></mml:math></inline-formula> representing magnetic susceptibility related contributions [<xref ref-type="bibr" rid="B27">27</xref>].</p>
<p>The most common way of <inline-formula><mml:math id="M25"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>-weighted imaging is gradient recalled echo (GRE) imaging. The MR signal magnitude <italic>S</italic><sub><italic>m</italic></sub>(&#x003B8;) created by a spoiled GRE pulse sequence is:</p>
<disp-formula id="E2"><label>(2)</label><mml:math id="M26"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mi>m</mml:mi></mml:msub><mml:mo stretchy='false'>(</mml:mo><mml:mi>&#x003B8;</mml:mi><mml:mo stretchy='false'>)</mml:mo><mml:mtext>&#x02009;</mml:mtext><mml:mo>=</mml:mo><mml:mtext>&#x02009;</mml:mtext><mml:msub><mml:mi>S</mml:mi><mml:mn>0</mml:mn></mml:msub><mml:mi>s</mml:mi><mml:mi>i</mml:mi><mml:mi>n</mml:mi><mml:mo stretchy='false'>(</mml:mo><mml:mi>&#x003B8;</mml:mi><mml:mo stretchy='false'>)</mml:mo><mml:mi>e</mml:mi><mml:mi>x</mml:mi><mml:mi>p</mml:mi><mml:mrow><mml:mo>(</mml:mo><mml:mrow><mml:mo>&#x02212;</mml:mo><mml:mi>T</mml:mi><mml:mi>E</mml:mi><mml:mo>/</mml:mo><mml:msubsup><mml:mi>T</mml:mi><mml:mn>2</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow><mml:mo>)</mml:mo></mml:mrow><mml:mfrac><mml:mrow><mml:mrow><mml:mo>[</mml:mo><mml:mrow><mml:mn>1</mml:mn><mml:mo>&#x02212;</mml:mo><mml:mi>e</mml:mi><mml:mi>x</mml:mi><mml:mi>p</mml:mi><mml:mrow><mml:mo>(</mml:mo><mml:mrow><mml:mo>&#x02212;</mml:mo><mml:mi>T</mml:mi><mml:mi>R</mml:mi><mml:mo>/</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mn>1</mml:mn></mml:msub></mml:mrow><mml:mo>)</mml:mo></mml:mrow></mml:mrow><mml:mo>]</mml:mo></mml:mrow></mml:mrow><mml:mrow><mml:mrow><mml:mo>[</mml:mo><mml:mrow><mml:mn>1</mml:mn><mml:mo>&#x02212;</mml:mo><mml:mi>c</mml:mi><mml:mi>o</mml:mi><mml:mi>s</mml:mi><mml:mrow><mml:mo>(</mml:mo><mml:mi>&#x003B8;</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mi>e</mml:mi><mml:mi>x</mml:mi><mml:mi>p</mml:mi><mml:mrow><mml:mo>(</mml:mo><mml:mrow><mml:mo>&#x02212;</mml:mo><mml:mi>T</mml:mi><mml:mi>R</mml:mi><mml:mo>/</mml:mo><mml:msub><mml:mi>T</mml:mi><mml:mn>1</mml:mn></mml:msub></mml:mrow><mml:mo>)</mml:mo></mml:mrow></mml:mrow><mml:mo>]</mml:mo></mml:mrow></mml:mrow></mml:mfrac></mml:mrow></mml:math></disp-formula>
<p>with <italic>S</italic><sub>0</sub> representing the spin density, <italic>TR</italic> the repetition time, <italic>TE</italic> the echo time defined by the time between MR signal excitation and MR signal readout [<xref ref-type="bibr" rid="B28">28</xref>], <italic>T</italic><sub>1</sub> and <inline-formula><mml:math id="M27"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> are tissue specific longitudinal and effective transversal relaxation time constants and &#x003B8; is the flip angle about which the magnetization is deflected by the excitation RF pulse. If <italic>TR</italic> and <italic>T</italic><sub>1</sub> are being kept constant Equation (2) can be simplified to:</p>
<disp-formula id="E3"><label>(3)</label><mml:math id="M28"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mi>m</mml:mi></mml:msub><mml:mo stretchy='false'>(</mml:mo><mml:mi>&#x003B8;</mml:mi><mml:mo stretchy='false'>)</mml:mo><mml:mo>&#x0221D;</mml:mo><mml:mi>e</mml:mi><mml:mi>x</mml:mi><mml:mi>p</mml:mi><mml:mrow><mml:mo>(</mml:mo><mml:mrow><mml:mo>&#x02212;</mml:mo><mml:mi>T</mml:mi><mml:mi>E</mml:mi><mml:mo>/</mml:mo><mml:msubsup><mml:mi>T</mml:mi><mml:mn>2</mml:mn><mml:mo>&#x02217;</mml:mo></mml:msubsup></mml:mrow><mml:mo>)</mml:mo></mml:mrow></mml:mrow></mml:math></disp-formula>
<p>Exploiting this relationship <inline-formula><mml:math id="M29"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> can be estimated by acquiring a series of images at different echo times <italic>TE</italic> followed by an exponential fit of the measured signal intensity vs. the echo time <italic>TE</italic>. This is commonly realized by using multi echo gradient echo (MEGRE) pulse sequences, which employ a series of dephasing and refocusing gradients to quickly acquire a series of <inline-formula><mml:math id="M30"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> sensitized images at several echo times as illustrated in Figure <xref ref-type="fig" rid="F1">1</xref>. <inline-formula><mml:math id="M31"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> weighted MRI is most sensitive to field perturbations when <italic>TE</italic> is equal to <inline-formula><mml:math id="M32"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> [<xref ref-type="bibr" rid="B29">29</xref>]. Exponential fitting of the signal decay can be done either for each voxel individually or for the mean signal within a region of interest. Single voxel fitting is more prone to noise but provides spatially resolved information in the form of relaxation maps (Figure <xref ref-type="fig" rid="F1">1</xref>). Besides mono-exponential fitting also multi-exponential fitting can be applied, if multiple signal compartments with different <inline-formula><mml:math id="M33"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> relaxation times are expected within an imaging voxel.</p>
<disp-formula id="E4"><label>(4)</label><mml:math id="M34"><mml:mtable columnalign='left'><mml:mtr><mml:mtd><mml:msub><mml:mi>S</mml:mi><mml:mi>m</mml:mi></mml:msub><mml:mo stretchy='false'>(</mml:mo><mml:mi>&#x003B8;</mml:mi><mml:mo stretchy='false'>)</mml:mo><mml:mo>&#x0221D;</mml:mo><mml:msub><mml:mi>S</mml:mi><mml:mn>1</mml:mn></mml:msub><mml:mi>e</mml:mi><mml:mi>x</mml:mi><mml:mi>p</mml:mi><mml:mrow><mml:mo>(</mml:mo><mml:mrow><mml:mo>&#x02212;</mml:mo><mml:mi>T</mml:mi><mml:mi>E</mml:mi><mml:msup><mml:mo>/</mml:mo><mml:mn>1</mml:mn></mml:msup><mml:msubsup><mml:mi>T</mml:mi><mml:mn>2</mml:mn><mml:mo>&#x02217;</mml:mo></mml:msubsup></mml:mrow><mml:mo>)</mml:mo></mml:mrow><mml:mtext>&#x02009;</mml:mtext><mml:mo>+</mml:mo><mml:mtext>&#x02009;</mml:mtext><mml:msub><mml:mi>S</mml:mi><mml:mn>2</mml:mn></mml:msub><mml:mi>e</mml:mi><mml:mi>x</mml:mi><mml:mi>p</mml:mi><mml:mrow><mml:mo>(</mml:mo><mml:mrow><mml:mo>&#x02212;</mml:mo><mml:mi>T</mml:mi><mml:mi>E</mml:mi><mml:msup><mml:mo>/</mml:mo><mml:mn>2</mml:mn></mml:msup><mml:msubsup><mml:mi>T</mml:mi><mml:mn>2</mml:mn><mml:mo>&#x02217;</mml:mo></mml:msubsup></mml:mrow><mml:mo>)</mml:mo></mml:mrow><mml:mtext>&#x02009;</mml:mtext><mml:mo>+</mml:mo><mml:mtext>&#x02009;</mml:mtext><mml:mo>&#x02026;</mml:mo></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mtext>&#x000A0;&#x000A0;&#x000A0;&#x000A0;&#x000A0;&#x000A0;&#x000A0;&#x000A0;&#x000A0;&#x000A0;&#x000A0;&#x000A0;</mml:mtext><mml:mo>+</mml:mo><mml:mtext>&#x02009;</mml:mtext><mml:msub><mml:mi>S</mml:mi><mml:mi>n</mml:mi></mml:msub><mml:mi>e</mml:mi><mml:mi>x</mml:mi><mml:mi>p</mml:mi><mml:mrow><mml:mo>(</mml:mo><mml:mrow><mml:mo>&#x02212;</mml:mo><mml:mi>T</mml:mi><mml:mi>E</mml:mi><mml:msup><mml:mo>/</mml:mo><mml:mi>n</mml:mi></mml:msup><mml:msubsup><mml:mi>T</mml:mi><mml:mn>2</mml:mn><mml:mo>&#x02217;</mml:mo></mml:msubsup></mml:mrow><mml:mo>)</mml:mo></mml:mrow></mml:mtd></mml:mtr></mml:mtable></mml:math></disp-formula>
<p>Here S<sub>1</sub>, S<sub>2</sub>, S<sub><italic>n</italic></sub> represent the relative volume fractions of the different compartments with their corresponding effective transverse relaxation times <sup>1</sup><inline-formula><mml:math id="M35"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, <sup>2</sup><inline-formula><mml:math id="M36"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, and <sup><italic>n</italic></sup><inline-formula><mml:math id="M37"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>.</p>
<fig id="F1" position="float">
<label>Figure 1</label>
<caption><p><inline-formula><mml:math id="M38"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> decay and <inline-formula><mml:math id="M39"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>-weighted image contrast. Top left: Plot of signal intensity over echo time for <inline-formula><mml:math id="M40"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> weighted imaging. Bottom: Example of mid-ventricular short axis views of the human heart obtained at 7.0 T. Images were acquired with increasing <inline-formula><mml:math id="M41"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>-weighting (from left to right). Top right: Corresponding myocardial <inline-formula><mml:math id="M42"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> map superimposed to a FLASH CINE image.</p></caption>
<graphic xlink:href="fphy-05-00022-g0001.tif"/>
</fig>
<p><inline-formula><mml:math id="M43"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> relaxation is blood oxygenation level dependent and provides a functional MR contrast which serves as the basis of functional brain mapping [<xref ref-type="bibr" rid="B3">3</xref>, <xref ref-type="bibr" rid="B26">26</xref>]. The effect results from a change of the magnetic susceptibility of hemoglobin (Hb) depending on its oxygenation state. Oxygenated hemoglobin is diamagnetic and has minor effect on magnetic field homogeneity. Deoxygenated hemoglobin in contrast is paramagnetic and causes magnetic field perturbations on a microscopic level resulting in spin dephasing and signal loss. <inline-formula><mml:math id="M44"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>-weighted MRI is sensitive to changes in the amount of deoxygenated Hb (deoxy Hb) per tissue volume element (voxel). <inline-formula><mml:math id="M45"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> changes and corresponding signal attenuation in <inline-formula><mml:math id="M46"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>-weighted MR images can hence result from a change in hemoglobin oxygenation or a change of the tissue blood volume fraction. The discovery of the BOLD phenomenon led to the development of functional MRI for mapping of human brain function, but also inspired research into BOLD imaging and <inline-formula><mml:math id="M47"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping of the heart [<xref ref-type="bibr" rid="B9">9</xref>, <xref ref-type="bibr" rid="B30">30</xref>].</p>
<p><inline-formula><mml:math id="M48"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> sensitized imaging and mapping are widely assumed to provide a surrogate of oxygenation. Yet the factors impacting the transverse relaxation rate other than oxygenation are numerous including macroscopic magnetic field inhomogeneities, blood volume fraction and hematocrit [<xref ref-type="bibr" rid="B31">31</xref>]. Considering a biologic tissue with a specific blood volume fraction BVf, a hematocrit Hct, and a local blood oxygen saturation <italic>So</italic><sub>2</sub>, <inline-formula><mml:math id="M49"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> can be modeled as:</p>
<disp-formula id="E5"><label>(5)</label><mml:math id="M50"><mml:mtable columnalign='left'><mml:mtr><mml:mtd><mml:mfrac><mml:mn>1</mml:mn><mml:mrow><mml:msubsup><mml:mi>T</mml:mi><mml:mn>2</mml:mn><mml:mo>&#x02217;</mml:mo></mml:msubsup></mml:mrow></mml:mfrac><mml:mo>=</mml:mo><mml:mtext>&#x000A0;</mml:mtext><mml:mfrac><mml:mn>1</mml:mn><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow></mml:mfrac><mml:mtext>&#x02009;</mml:mtext><mml:mo>+</mml:mo><mml:mtext>&#x02009;</mml:mtext><mml:mi>&#x003B3;</mml:mi><mml:mrow><mml:mo>|</mml:mo><mml:mrow><mml:mo>&#x00394;</mml:mo><mml:mi>B</mml:mi></mml:mrow><mml:mo>|</mml:mo></mml:mrow><mml:mo>=</mml:mo><mml:mfrac><mml:mn>1</mml:mn><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow></mml:mfrac></mml:mtd></mml:mtr><mml:mtr><mml:mtd><mml:mtext>&#x000A0;&#x000A0;&#x000A0;&#x000A0;&#x000A0;&#x000A0;&#x000A0;&#x000A0;&#x000A0;</mml:mtext><mml:mo>+</mml:mo><mml:mtext>&#x02009;</mml:mtext><mml:mi>B</mml:mi><mml:mi>V</mml:mi><mml:mi>f</mml:mi><mml:mo>&#x000B7;</mml:mo><mml:mi>&#x003B3;</mml:mi><mml:mo>&#x000B7;</mml:mo><mml:mfrac><mml:mn>4</mml:mn><mml:mn>3</mml:mn></mml:mfrac><mml:mo>&#x000B7;</mml:mo><mml:mi>&#x003C0;</mml:mi><mml:mo>&#x000B7;</mml:mo><mml:mo>&#x00394;</mml:mo><mml:msub><mml:mi>&#x003C7;</mml:mi><mml:mn>0</mml:mn></mml:msub><mml:mo>&#x000B7;</mml:mo><mml:mi>H</mml:mi><mml:mi>c</mml:mi><mml:mi>t</mml:mi><mml:mo>&#x000B7;</mml:mo><mml:mrow><mml:mo>(</mml:mo><mml:mrow><mml:mn>1</mml:mn><mml:mo>&#x02212;</mml:mo><mml:mi>S</mml:mi><mml:msub><mml:mi>o</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>)</mml:mo></mml:mrow><mml:msub><mml:mi>B</mml:mi><mml:mn>0</mml:mn></mml:msub><mml:mo>+</mml:mo><mml:mi>&#x003B3;</mml:mi><mml:mrow><mml:mo>|</mml:mo><mml:mrow><mml:mo>&#x00394;</mml:mo><mml:msub><mml:mi>B</mml:mi><mml:mrow><mml:mi>o</mml:mi><mml:mi>t</mml:mi><mml:mi>h</mml:mi><mml:mi>e</mml:mi><mml:mi>r</mml:mi></mml:mrow></mml:msub></mml:mrow><mml:mo>|</mml:mo></mml:mrow></mml:mtd></mml:mtr></mml:mtable></mml:math></disp-formula>
<p>with &#x003B3;|&#x00394;<italic>B</italic><sub><italic>other</italic></sub>| representing additional magnetic field inhomogeneities such as macroscopic field changes [<xref ref-type="bibr" rid="B32">32</xref>, <xref ref-type="bibr" rid="B33">33</xref>] and &#x00394;&#x003C7;<sub>0</sub> &#x0003D; 3.318 ppm being the magnetic susceptibility difference of fully oxygenated and fully deoxygenated hemoglobin (in SI units) [<xref ref-type="bibr" rid="B34">34</xref>]. When tissue blood volume fraction, hematocrit level and macroscopic <italic>B</italic><sub>0</sub> contributions are known and echo times are greater than a characteristic time Equation (5) can be employed to non-invasively estimate tissue oxygenation using MRI [<xref ref-type="bibr" rid="B33">33</xref>]. It should be noted that a reduction in the tissue blood volume fraction can result in a <inline-formula><mml:math id="M51"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> increase which could be misinterpreted as an oxygenation increase and hence result in premature conclusions if the effect of blood volume fraction is not taken into account [<xref ref-type="bibr" rid="B35">35</xref>]. If all the parameters are considered correctly, <inline-formula><mml:math id="M52"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> can serve as a non-invasive means to probe physiology <italic>in vivo</italic>. It should be noted that <italic>T</italic><sub>2</sub> changes, e.g., caused by alterations in tissue water content or distribution are also reflected in <inline-formula><mml:math id="M53"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> and hence should be considered as potential confounders.</p>
</sec>
<sec>
<title>Benefits of myocardial <inline-formula><mml:math id="M54"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping at higher magnetic field strengths</title>
<p>The magnetization M of a material in response to an applied magnetic field is given by its magnetic susceptibility &#x003C7; and the strength of the applied magnetic field H:</p>
<disp-formula id="E6"><label>(6)</label><mml:math id="M55"><mml:mrow><mml:mi>M</mml:mi><mml:mtext>&#x02009;</mml:mtext><mml:mo>=</mml:mo><mml:mtext>&#x02009;</mml:mtext><mml:mi>&#x003C7;</mml:mi><mml:mi>H</mml:mi></mml:mrow></mml:math></disp-formula>
<p>This relationship results in a linear increase of magnetic field perturbations induced by microscopic susceptibility changes&#x02014;the main driving force behind <inline-formula><mml:math id="M56"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> decay&#x02014;when moving to higher magnetic fields. The effect has been confirmed for myocardial <inline-formula><mml:math id="M57"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M58"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> &#x0003D; 1/<inline-formula><mml:math id="M59"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>) <italic>in vivo</italic> rendering <inline-formula><mml:math id="M60"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping at ultrahigh magnetic fields (<italic>B</italic><sub><italic>0</italic></sub> &#x02265; 7.0 T) particularly appealing [<xref ref-type="bibr" rid="B36">36</xref>] (Figure <xref ref-type="fig" rid="F2">2</xref>). The enhanced susceptibility effects at 7.0 T may be useful to extend the dynamic range of the sensitivity for monitoring <inline-formula><mml:math id="M61"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> changes and to lower their detection level. Another advantage of performing <inline-formula><mml:math id="M62"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> weighted imaging and mapping at ultrahigh magnetic field strengths (UHF) is that the signal-to-noise ratio (SNR) gain achieved at higher fields can be used to improve the spatial resolution [<xref ref-type="bibr" rid="B37">37</xref>, <xref ref-type="bibr" rid="B38">38</xref>]. This reduction in voxel sizes lowers the impact of macroscopic magnetic field gradients on intra-voxel dephasing and hence <inline-formula><mml:math id="M63"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> which otherwise can be a concern especially in the vicinity of strong susceptibility transitions. Transitioning to higher magnetic field strengths runs the additional benefit that the in-phase inter-echo time governed by the fat-water phase shift between the water and main fat peak of about 3.5 ppm is reduced from approximately 4.5 ms (223 Hz) at 1.5 T to 0.96 ms (1,043 Hz) at 7.0 T. This enables rapid acquisition of multiple echoes with different <inline-formula><mml:math id="M64"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> sensitization and facilitates high spatio-temporally resolved myocardial CINE <inline-formula><mml:math id="M65"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping of the human heart [<xref ref-type="bibr" rid="B39">39</xref>]. Taking advantage of this technique, <inline-formula><mml:math id="M66"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping at ultrahigh magnetic fields has been suggested as a means to probe myocardial physiology and to advance myocardial tissue characterization.</p>
<fig id="F2" position="float">
<label>Figure 2</label>
<caption><p>Relation of ventricular septal <inline-formula><mml:math id="M67"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> and static magnetic field strength. Myocardial <inline-formula><mml:math id="M68"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>R</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> increases linearly with magnetic field strength (adapted from Meloni et al. [<xref ref-type="bibr" rid="B36">36</xref>] with permission from John Wiley and Sons).</p></caption>
<graphic xlink:href="fphy-05-00022-g0002.tif"/>
</fig>
</sec>
</sec>
<sec id="s2">
<title>Challenges and technical solutions for cardiac MRI at ultrahigh magnetic fields</title>
<sec>
<title>Enabling radio frequency antenna technology</title>
<p>Imaging the heart&#x02014;a deep-lying target region surrounded by the lung within the large volume of the thorax&#x02014;at ultrahigh magnetic field strengths poses a severe challenge due to the short wavelength of the proton resonance frequency in tissue (&#x003BB;<sub>myocardium</sub> &#x02248; 12 cm at 7.0 T). As a result, non-uniformities in the transmission field (<inline-formula><mml:math id="M69"><mml:msubsup><mml:mrow><mml:mtext>B</mml:mtext></mml:mrow><mml:mrow><mml:mn>1</mml:mn></mml:mrow><mml:mrow><mml:mo>&#x0002B;</mml:mo></mml:mrow></mml:msubsup></mml:math></inline-formula>) can cause shading, massive signal drop-off or signal void in the images up to non-diagnostic image quality. These constraints were reported being a concern in CMR at 3.0 T [<xref ref-type="bibr" rid="B40">40</xref>] and were to be expected to pose a major obstacle for CMR at UHF.</p>
<p>A plethora of reports have evolved during the past years introducing technical innovations in RF antenna design to overcome non-uniform transmission fields. Local transceiver (TX/RX) and multi-channel transmission arrays in conjunction with multi-channel local receive arrays have been suggested as possible solutions. Eminent developments put building blocks to use consisting of stripline elements [<xref ref-type="bibr" rid="B41">41</xref>&#x02013;<xref ref-type="bibr" rid="B45">45</xref>], electrical dipoles [<xref ref-type="bibr" rid="B45">45</xref>&#x02013;<xref ref-type="bibr" rid="B51">51</xref>], dielectric resonant antennas [<xref ref-type="bibr" rid="B52">52</xref>], slot antennas [<xref ref-type="bibr" rid="B53">53</xref>], and loop elements [<xref ref-type="bibr" rid="B54">54</xref>&#x02013;<xref ref-type="bibr" rid="B59">59</xref>]. Rigid, flexible and modular configurations have been exploited. Irrespective of the building block technology, a trend toward higher numbers of transmit and receive elements can be observed with the purpose to advance anatomic coverage [<xref ref-type="bibr" rid="B47">47</xref>, <xref ref-type="bibr" rid="B54">54</xref>&#x02013;<xref ref-type="bibr" rid="B59">59</xref>] and to add degrees of freedom for transmission field shaping [<xref ref-type="bibr" rid="B60">60</xref>].</p>
<p>Figure <xref ref-type="fig" rid="F3">3</xref> compiles developments of loop element based transceiver configurations optimized for CMR at 7.0 T. A 4-channel TX/RX [<xref ref-type="bibr" rid="B55">55</xref>] (Figure <xref ref-type="fig" rid="F3">3A</xref>) and an 8-channel TX/RX [<xref ref-type="bibr" rid="B58">58</xref>] (Figure <xref ref-type="fig" rid="F3">3B</xref>) one-dimensional array were reported and extended to a 16-channel two-dimensional design [<xref ref-type="bibr" rid="B56">56</xref>] (Figure <xref ref-type="fig" rid="F3">3C</xref>). A modular 32-channel TX/RX [<xref ref-type="bibr" rid="B59">59</xref>] (Figure <xref ref-type="fig" rid="F3">3D</xref>) array further exploited the two-dimensional building block layout.</p>
<fig id="F3" position="float">
<label>Figure 3</label>
<caption><p>Examples of multi-channel transceiver arrays tailored for cardiac MR at 7.0 T. Top: Photographs of cardiac optimized 7.0 T transceiver coil arrays including (left to right) <bold>(A)</bold> a four-channel, <bold>(B)</bold> an eight channel, <bold>(C)</bold> a 16 channel and <bold>(D)</bold> a 32 channel loop array configuration together with an <bold>(E)</bold> eight channel and <bold>(F)</bold> 16 channel bow tie antenna array. For all configurations the RF elements are used for transmission and reception. Center and bottom: Four chamber and short axis views of the heart derived from 2D CINE FLASH acquisitions using the RF coil arrays shown on the left and a spatial resolution of (1.4 &#x000D7; 1.4. &#x000D7; 4.0) mm<sup>3</sup> (from Niendorf et al. [<xref ref-type="bibr" rid="B113">113</xref>] with permission from John Wiley and Sons).</p></caption>
<graphic xlink:href="fphy-05-00022-g0003.tif"/>
</fig>
<p>Electric dipoles hold the benefit of a linearly polarized current pattern with the RF energy being directed perpendicular to the dipole along the Poynting vector to the subject. As a consequence, the excitation field is symmetrical and uniform and comes with ample depth penetration [<xref ref-type="bibr" rid="B48">48</xref>] which renders electric dipoles particularly promising for MR of the upper torso and the heart. This property formed the starting point for explorations into electric dipole configurations [<xref ref-type="bibr" rid="B46">46</xref>&#x02013;<xref ref-type="bibr" rid="B48">48</xref>, 50, <xref ref-type="bibr" rid="B51">51</xref>]. Due to their length straight dipole elements are unfavorable if not unfeasible for high density multi-dimensional transceiver coil arrays [<xref ref-type="bibr" rid="B48">48</xref>]. To address this issue, the fractionated dipole concept splits the dipole&#x00027;s legs into segments interconnected by capacitors or inductors to achieve dipole shortening. Reduced SAR levels, moderate coupling and homogeneous <inline-formula><mml:math id="M70"><mml:msubsup><mml:mrow><mml:mtext>B</mml:mtext></mml:mrow><mml:mrow><mml:mn>1</mml:mn></mml:mrow><mml:mrow><mml:mo>&#x0002B;</mml:mo></mml:mrow></mml:msubsup></mml:math></inline-formula> have been reported for prostate imaging using an eight-element array consisting of fractionated dipoles [<xref ref-type="bibr" rid="B51">51</xref>]. A combined 16-channel loop-dipole transceiver array exploiting the fractionated dipole antenna design provided cardiac images acquired at 7.0 T exhibiting high SNR and <inline-formula><mml:math id="M71"><mml:msubsup><mml:mrow><mml:mtext>B</mml:mtext></mml:mrow><mml:mrow><mml:mn>1</mml:mn></mml:mrow><mml:mrow><mml:mo>&#x0002B;</mml:mo></mml:mrow></mml:msubsup></mml:math></inline-formula> transmit efficiency [<xref ref-type="bibr" rid="B50">50</xref>]. As an alternative, shortening of the effective antenna length can be achieved for a bow tie shaped &#x003BB;/2-dipole antenna by immersing it in D<sub>2</sub>O. Following this achievement electric dipole configurations optimized for UHF-CMR have been reported using 8 or 16 bow tie antenna building blocks [<xref ref-type="bibr" rid="B47">47</xref>] (Figures <xref ref-type="fig" rid="F3">3E,F</xref>). As a result of these research efforts, dedicated RF antenna arrays are now available which facilitate cardiac MRI at 7.0 T with rather uniform signal intensities across the heart.</p>
<p>In summary, explorations into enabling RF antenna technology underlined the benefits of many-channel high-density arrays for UHF-CMR.</p>
</sec>
<sec>
<title>Ancillary devices for cardiac synchronization</title>
<p>Imaging the heart requires synchronization of the data acquisition with the cardiac cycle. Magneto hydrodynamic (MHD) effects severely disturb the electrocardiogram (ECG) [<xref ref-type="bibr" rid="B61">61</xref>&#x02013;<xref ref-type="bibr" rid="B63">63</xref>] commonly applied for cardiac triggering and gating at clinical field strengths [<xref ref-type="bibr" rid="B64">64</xref>&#x02013;<xref ref-type="bibr" rid="B66">66</xref>] (Figure <xref ref-type="fig" rid="F4">4</xref>). Distortions of the ECG&#x00027;s S-T segment are caused by the increased MHD impact during systolic aortic flow [<xref ref-type="bibr" rid="B67">67</xref>]. The S-T elevation might be mis-interpreted as an R-wave. Consequently, image quality is impaired due to the mis-detected onset of a cardiac cycle. The propensity to MHD effects is pronounced at ultrahigh magnetic field strengths [<xref ref-type="bibr" rid="B42">42</xref>, <xref ref-type="bibr" rid="B68">68</xref>, <xref ref-type="bibr" rid="B69">69</xref>]. An MR-stethoscope has been proposed as an alternative to ECG gating and triggering putting acoustic signals to use which have been reported to be immune to interferences with electromagnetic fields. With this practical solution the first heart tone of the phonocardiogram is detected, which marks the onset of the acoustic cardiac cycle. The minor latency between the onset of the electrophysiological cardiac activity and the onset of the acoustic cardiac activity allows prospectively triggered and retrospectively gated acquisitions. Acoustic triggering can hence be used with all pulse sequences that support ECG triggering without the need of sequence adjustments. Reliable trigger information has been demonstrated when using acoustic cardiac triggering and gating for UHF-CMR (Figure <xref ref-type="fig" rid="F4">4</xref>) [<xref ref-type="bibr" rid="B61">61</xref>, <xref ref-type="bibr" rid="B68">68</xref>, <xref ref-type="bibr" rid="B70">70</xref>]. Further alternatives for cardiac synchronization include post-processing of the ECG signal to reduce MHD induced distortions of the ECG trace [<xref ref-type="bibr" rid="B71">71</xref>, <xref ref-type="bibr" rid="B72">72</xref>]. Wideband radar, magnetic field probes or optical systems have been proposed for physiological monitoring [<xref ref-type="bibr" rid="B73">73</xref>&#x02013;<xref ref-type="bibr" rid="B75">75</xref>].</p>
<fig id="F4" position="float">
<label>Figure 4</label>
<caption><p>Comparison of ECG and acoustic triggering or gating showing system schemes (left), signal traces acquired in the isocenter of a 7.0 T magnet for 18 cardiac cycles (middle) and corresponding four chamber views acquired at 7.0 T with the respective approaches (right). The ECG gated image shows severe artifacts due to incorrect cardiac synchronization, while the acoustically triggered image reveals decent image quality with good blood myocardium contrast and clear delineation of subtle structures.</p></caption>
<graphic xlink:href="fphy-05-00022-g0004.tif"/>
</fig>
</sec>
<sec>
<title><inline-formula><mml:math id="M72"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> imaging techniques</title>
<p><inline-formula><mml:math id="M73"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> sensitized imaging and mapping is commonly performed employing gradient echo imaging independent of magnetic field strength. To decrease acquisition times multi echo gradient echo techniques (MEGRE) acquiring multiple echoes after each RF excitation instead of only one echo per repetition time <italic>TR</italic> are recommended for fast <inline-formula><mml:math id="M74"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping (Figure <xref ref-type="fig" rid="F5">5A</xref>, top). For myocardial <inline-formula><mml:math id="M75"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping cardiac triggered segmented acquisitions are commonly performed in end-expiratory breath hold conditions to avoid respiratory and cardiac motion and to reduce related macroscopic <italic>B</italic><sub><italic>0</italic></sub> field fluctuations.</p>
<fig id="F5" position="float">
<label>Figure 5</label>
<caption><p>Acquisition schemes used for <inline-formula><mml:math id="M76"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> weighted imaging/mapping and corresponding <inline-formula><mml:math id="M77"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> maps. <bold>(A) (I)</bold> multi echo gradient echo (MEGRE) acquisition, <bold>(II)</bold> multi shot (MS) interleaved multi gradient echo acquisition, <bold>(III)</bold> multi breath hold CINE (MB-CINE) interleaved multi gradient echo acquisition. <bold>(B)</bold> Comparison of <inline-formula><mml:math id="M78"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> maps derived from a homogenous phantom resembling myocardial tissue acquired using the three different approaches and slice thicknesses from 8 to 2.5 mm. All acquisition strategies provide similar <inline-formula><mml:math id="M79"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> maps. Through plane dephasing is reduced for lower slice thickness (adapted from Hezel et al. [<xref ref-type="bibr" rid="B39">39</xref>].)</p></caption>
<graphic xlink:href="fphy-05-00022-g0005.tif"/>
</fig>
<p>The used echo times should be adapted to sufficiently cover the <inline-formula><mml:math id="M80"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> decay. As the contributing fat and water signal are oscillating at different frequencies mapping algorithms must either account for or compensate the varying signal intensity from fat and water. Acquiring <inline-formula><mml:math id="M81"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>-weighted images at times when fat and water are equally contributing to the MR signal (in-phase) is the simplest approach to achieve this goal. At 7.0 T this is the case for echo times being a multiple of about 0.96 ms due to the chemical shift between the main fat and water peaks of approximately 3.5 ppm (1,043 Hz). Acquisition of echoes with an inter-echo spacing of &#x0007E;1 ms constitutes a challenge due to gradient amplitude and rise time limitations, especially when large acquisition matrix sizes are used. Alternatively, interleaved acquisitions can be performed by distributing the acquisition of neighboring echoes across multiple excitations (Figure <xref ref-type="fig" rid="F5">5A</xref>, middle). This approach permits low inter-echo spacing even for large matrix sizes but results in longer scan times since more than one <italic>TR</italic> is required to acquire a full <inline-formula><mml:math id="M82"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> decay series. While <inline-formula><mml:math id="M83"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping at clinical field strengths is limited to single cardiac phase acquisitions, CINE <inline-formula><mml:math id="M84"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping covering the entire cardiac cycle is feasible at UHF [<xref ref-type="bibr" rid="B39">39</xref>]. This advanced capability is facilitated by two benefits of UHF-MR. First, due to transversal relaxation time shortening at ultrahigh magnetic fields, <italic>TE</italic> can be limited to a range of approximately <italic>TE</italic> &#x0003D; 0 ms to <italic>TE</italic> &#x0003D; 15 ms to properly sample the myocardial <inline-formula><mml:math id="M85"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> decay. This approach is beneficial for reducing the duration of the gradient echo trains compared to lower magnetic field strengths enabling breath held multi echo CINE acquisitions. Second, the reduced in-phase echo spacing permits acquisition of a sufficient number of echoes needed to cover the signal decay and to provide an appropriate number of data points for signal fitting. Interleaving of echo times can be combined with distributing the acquisition across multiple breath-holds to ease gradient constraints and limit breath-hold durations for each acquisition (Figure <xref ref-type="fig" rid="F5">5A</xref>, bottom). All described acquisition strategies are capable of producing <inline-formula><mml:math id="M86"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> maps of similar fidelity as illustrated in Figure <xref ref-type="fig" rid="F5">5B</xref> for a homogenous MR phantom resembling the relaxation properties of human myocardium. To reduce the effect of macroscopic magnetic field gradients on spin dephasing and <inline-formula><mml:math id="M87"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, small voxel sizes are preferable. Of course this preference has to be balanced with SNR requirements for accurate mapping which can be challenging particularly at lower magnetic field strengths. Figure <xref ref-type="fig" rid="F5">5B</xref> compares the effect of slice thickness on <inline-formula><mml:math id="M88"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>. While maps acquired with slice thicknesses of 6 mm or above show intra-voxel dephasing and <inline-formula><mml:math id="M89"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> decrease pronounced at the phantom interfaces, this effect is mitigated for slice thicknesses of 4 mm or less resulting in a more uniform <inline-formula><mml:math id="M90"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> map. Employing the described multi-breath hold CINE technique at 7.0 T, CINE <inline-formula><mml:math id="M91"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping with more than 20 cardiac phases is feasible which allows monitoring of myocardial <inline-formula><mml:math id="M92"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> across the cardiac cycle (Figure <xref ref-type="fig" rid="F6">6</xref>).</p>
<fig id="F6" position="float">
<label>Figure 6</label>
<caption><p>Example of cardiac phase resolved myocardial <inline-formula><mml:math id="M93"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping of a short axis view of a healthy volunteer (10 out of 20 phases shown). Spatial resolution &#x0003D; (1.1 &#x000D7; 1.1 &#x000D7; 4.0) mm<sup>3</sup>. Temporal resolution &#x0003D; 37 ms. <inline-formula><mml:math id="M94"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> variations can be observed across the cardiac cycle. TT indicates the time since the trigger.</p></caption>
<graphic xlink:href="fphy-05-00022-g0006.tif"/>
</fig>
<p>In contrast to gradient echo imaging Rapid Acquisition with Relaxation Enhancement (RARE) imaging is rather insensitive to <italic>B</italic><sub><italic>0</italic></sub> inhomogeneities, provides images free of distortion due to the use of RF refocused echoes and inherently suppresses blood signal. Cardiac RARE imaging at 7.0 T has been shown to be feasible [<xref ref-type="bibr" rid="B76">76</xref>]. These results&#x02014;in conjunction with the challenges and opportunities of myocardial <inline-formula><mml:math id="M95"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping at UHF&#x02014;build the starting point for explorations into RARE based <inline-formula><mml:math id="M96"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping of the heart at 7.0 T. An evolution time &#x003C4; inserted after the excitation RF pulse accrues an additional phase to the magnetization that reflects the <inline-formula><mml:math id="M97"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> effect [<xref ref-type="bibr" rid="B77">77</xref>] (Figure <xref ref-type="fig" rid="F7">7A</xref>). As a consequence, the Carr-Purcell-Meiboom-Gill condition cannot be met and destructive interferences between odd and even echo groups configuring the signal in RARE imaging impair the image [<xref ref-type="bibr" rid="B78">78</xref>, <xref ref-type="bibr" rid="B79">79</xref>]. Measures to account for this effect include displaced RARE [<xref ref-type="bibr" rid="B77">77</xref>, <xref ref-type="bibr" rid="B80">80</xref>], avoiding interferences by discarding one of both echo groups, resulting in an SNR loss of factor two. Split-echo variants hold the benefit that the full available signal is maintained [<xref ref-type="bibr" rid="B81">81</xref>] (Figure <xref ref-type="fig" rid="F7">7A</xref>). A series of <inline-formula><mml:math id="M98"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> weighted images derived from RARE imaging using evolution times &#x003C4; ranging from 2 to 14 ms is displayed in Figure <xref ref-type="fig" rid="F7">7B</xref> and demonstrates that the geometric integrity of the RARE images is maintained over the range of applied <inline-formula><mml:math id="M99"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> weighting. The corresponding <inline-formula><mml:math id="M100"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> map is shown in Figure <xref ref-type="fig" rid="F7">7C</xref>. MEGRE imaging results are shown for comparison and exhibited less myocardium to blood contrast due to the bright-blood characteristic of the technique. Consequently, the delineation of the myocardium in the corresponding <inline-formula><mml:math id="M101"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> map (Figure <xref ref-type="fig" rid="F7">7C</xref>) is more challenging compared to the RARE based <inline-formula><mml:math id="M102"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> map. The average effective transversal relaxation time derived from RARE imaging compares well to values previously reported for MEGRE approaches [<xref ref-type="bibr" rid="B39">39</xref>]. The concerns of RF power deposition and RF non-uniformity of RARE imaging were offset in this preliminary study. Split-echo RARE hence holds the potential to provide an alternative for <inline-formula><mml:math id="M103"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping free of geometric distortion and with high blood myocardium contrast.</p>
<fig id="F7" position="float">
<label>Figure 7</label>
<caption><p>RARE-based myocardial <inline-formula><mml:math id="M104"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping at 7.0 T. <bold>(A)</bold> Basic pulse sequence diagram of <inline-formula><mml:math id="M105"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> weighted split-echo RARE. <inline-formula><mml:math id="M106"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> weighting is introduced into RARE by adding an evolution time &#x003C4; after the excitation RF pulse. The dephasing gradient in frequency encoding direction is imbalanced (marked in gray) to avoid destructive interferences between odd and even echo groups. <bold>(B)</bold> <inline-formula><mml:math id="M107"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>-weighted split-echo RARE images of a short axis view employing evolution times ranging from &#x003C4; &#x0003D; 2 ms to &#x003C4; &#x0003D; 14 ms (left). MEGRE images obtained with echo times ranging from 2 to 14 ms (right). For improved visualization, the images do not exhibit identical windowing over the range of increasing susceptibility weighting. The myocardium was delineated and the contour is shown in the images with minimal &#x003C4;/TE. <bold>(C)</bold> <inline-formula><mml:math id="M108"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> maps derived from data in shown in <bold>(B)</bold> are depicted for the RARE (top) and the GRE (bottom) approach. The contours defined in the images with minimal &#x003C4;/TE were copied to the <inline-formula><mml:math id="M109"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> maps for better delineation of the myocardium.</p></caption>
<graphic xlink:href="fphy-05-00022-g0007.tif"/>
</fig>
</sec>
<sec>
<title>Assessment and control of main magnetic field homogeneity</title>
<p>The complex MR signal <italic>S</italic> (<italic>r, t</italic>) obtained by a gradient echo technique at a location <bold><italic>r</italic></bold> and time <italic>t</italic> after signal excitation is given by:</p>
<disp-formula id="E7"><label>(7)</label><mml:math id="M110"><mml:mrow><mml:mi>S</mml:mi><mml:mo stretchy='false'>(</mml:mo><mml:mi>r</mml:mi><mml:mo>,</mml:mo><mml:mi>t</mml:mi><mml:mo stretchy='false'>)</mml:mo><mml:mtext>&#x02009;</mml:mtext><mml:mo>=</mml:mo><mml:mtext>&#x02009;</mml:mtext><mml:mover accent='true'><mml:mi>S</mml:mi><mml:mo>&#x0005E;</mml:mo></mml:mover><mml:mo stretchy='false'>(</mml:mo><mml:mi>t</mml:mi><mml:mo stretchy='false'>)</mml:mo><mml:mo>&#x000B7;</mml:mo><mml:msup><mml:mi>e</mml:mi><mml:mrow><mml:mo>&#x02212;</mml:mo><mml:mi>i</mml:mi><mml:mi>&#x003D5;</mml:mi><mml:mo stretchy='false'>(</mml:mo><mml:mi>r</mml:mi><mml:mo>,</mml:mo><mml:mi>t</mml:mi><mml:mo stretchy='false'>)</mml:mo></mml:mrow></mml:msup><mml:mo>,</mml:mo><mml:mover accent='true'><mml:mi>S</mml:mi><mml:mo>&#x0005E;</mml:mo></mml:mover><mml:mo stretchy='false'>(</mml:mo><mml:mi>t</mml:mi><mml:mo stretchy='false'>)</mml:mo><mml:mo>&#x0221D;</mml:mo><mml:msub><mml:mi>S</mml:mi><mml:mn>0</mml:mn></mml:msub><mml:mo>&#x000B7;</mml:mo><mml:msup><mml:mi>e</mml:mi><mml:mrow><mml:mo>&#x02212;</mml:mo><mml:mfrac><mml:mi>t</mml:mi><mml:mrow><mml:msubsup><mml:mi>T</mml:mi><mml:mn>2</mml:mn><mml:mo>*</mml:mo></mml:msubsup></mml:mrow></mml:mfrac></mml:mrow></mml:msup></mml:mrow></mml:math></disp-formula>
<p>&#x0015C;(<italic>t</italic>) is the magnitude signal, <italic>i</italic> is the imaginary unit and &#x003D5; is the signal phase. The signal phase &#x003D5; can be written as a function of spatial location and time [<xref ref-type="bibr" rid="B82">82</xref>]:</p>
<disp-formula id="E8"><label>(8)</label><mml:math id="M111"><mml:mrow><mml:mi>&#x003D5;</mml:mi><mml:mo stretchy='false'>(</mml:mo><mml:mi>r</mml:mi><mml:mo>,</mml:mo><mml:mi>t</mml:mi><mml:mo stretchy='false'>)</mml:mo><mml:mo>=</mml:mo><mml:msub><mml:mi>&#x003D5;</mml:mi><mml:mn>0</mml:mn></mml:msub><mml:mo stretchy='false'>(</mml:mo><mml:mi>r</mml:mi><mml:mo stretchy='false'>)</mml:mo><mml:mo>&#x02212;</mml:mo><mml:mi>&#x003B3;</mml:mi><mml:mo>&#x000B7;</mml:mo><mml:mo>&#x00394;</mml:mo><mml:mi>B</mml:mi><mml:mo stretchy='false'>(</mml:mo><mml:mi>r</mml:mi><mml:mo stretchy='false'>)</mml:mo><mml:mo>&#x000B7;</mml:mo><mml:mi>t</mml:mi></mml:mrow></mml:math></disp-formula>
<p>with &#x003B3; being the gyromagnetic constant of the nucleus (for <sup>1</sup>H &#x003B3; &#x0003D; 2.675 &#x000D7; 10<sup>8</sup> rad/s/T) and &#x00394;<italic>B</italic>(<italic>r</italic>) representing local magnetic field deviations with regard to the main magnetic field strength. &#x003D5;<sub>0</sub>(<italic>r</italic>) represents a constant receiver phase offset, while the time-dependent phase component &#x003B3;&#x000B7;&#x00394;<italic>B</italic>(<italic>r</italic>)&#x000B7;<italic>t</italic> is dominated by the deviation from the static magnetic field and evolves linearly over time [<xref ref-type="bibr" rid="B83">83</xref>]. Assuming there are no other external sources of dephasing such as, e.g., motion or flow, the signal phase &#x003D5; serves as a direct measure of deviations from the main magnetic field <italic>B</italic><sub><italic>0</italic></sub>.</p>
<p>Equation (1) can be approximated as:</p>
<disp-formula id="E9"><label>(9)</label><mml:math id="M112"><mml:mrow><mml:mfrac><mml:mn>1</mml:mn><mml:mrow><mml:msubsup><mml:mi>T</mml:mi><mml:mn>2</mml:mn><mml:mo>&#x02217;</mml:mo></mml:msubsup></mml:mrow></mml:mfrac><mml:mo>=</mml:mo><mml:mfrac><mml:mn>1</mml:mn><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow></mml:mfrac><mml:mo>+</mml:mo><mml:mtext>&#x000A0;</mml:mtext><mml:mfrac><mml:mn>1</mml:mn><mml:mrow><mml:msubsup><mml:mi>T</mml:mi><mml:mn>2</mml:mn><mml:mo>&#x02032;</mml:mo></mml:msubsup></mml:mrow></mml:mfrac><mml:mo>&#x02245;</mml:mo><mml:mfrac><mml:mn>1</mml:mn><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow></mml:mfrac><mml:mo>+</mml:mo><mml:mi>&#x003B3;</mml:mi><mml:mrow><mml:mo>|</mml:mo><mml:mrow><mml:mo>&#x00394;</mml:mo><mml:mi>B</mml:mi></mml:mrow><mml:mo>|</mml:mo></mml:mrow></mml:mrow></mml:math></disp-formula>
<p>if a linear <italic>B</italic><sub><italic>0</italic></sub> gradient within a voxel is assumed [<xref ref-type="bibr" rid="B32">32</xref>]. This assumption is justified for typical voxel sizes used in cardiac <inline-formula><mml:math id="M113"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping at 7.0 T with an in-plane spatial resolution of about 1 mm and a slice thickness of 2&#x02013;4 mm [<xref ref-type="bibr" rid="B39">39</xref>, <xref ref-type="bibr" rid="B84">84</xref>]. |&#x00394;<italic>B</italic>| in Equation (9) includes microscopic magnetic field perturbations resulting from microstructural changes, blood oxygenation changes, iron accumulation etc. which are of diagnostic interest as well as macroscopic field changes, e.g., due to magnet imperfections or strong susceptibility transitions at air tissue interfaces. This dependency highlights the need to monitor and possibly compensate <italic>B</italic><sub><italic>0</italic></sub> inhomogeneities when performing <inline-formula><mml:math id="M114"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> assessment to make sure that <inline-formula><mml:math id="M115"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> decay reflects microscopic susceptibility changes rather than macroscopic field perturbations.</p>
<p>By acquiring images at two echo times (<italic>TE</italic>), the local magnetic field variations can be calculated at each voxel by making use of Equation (8):</p>
<disp-formula id="E10"><label>(10)</label><mml:math id="M116"><mml:mrow><mml:mo>&#x00394;</mml:mo><mml:mi>B</mml:mi><mml:mrow><mml:mo>(</mml:mo><mml:mi>r</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mo>=</mml:mo><mml:mfrac><mml:mrow><mml:mi>&#x003D5;</mml:mi><mml:mrow><mml:mo>(</mml:mo><mml:mrow><mml:mi>r</mml:mi><mml:mo>,</mml:mo><mml:mi>T</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>)</mml:mo></mml:mrow><mml:mo>&#x02212;</mml:mo><mml:mi>&#x003D5;</mml:mi><mml:mrow><mml:mo>(</mml:mo><mml:mrow><mml:mi>r</mml:mi><mml:mo>,</mml:mo><mml:mi>T</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mn>1</mml:mn></mml:msub></mml:mrow><mml:mo>)</mml:mo></mml:mrow></mml:mrow><mml:mrow><mml:mi>&#x003B3;</mml:mi><mml:mo>&#x000A0;</mml:mo><mml:mrow><mml:mo>(</mml:mo><mml:mrow><mml:mi>T</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mn>2</mml:mn></mml:msub><mml:mo>&#x02212;</mml:mo><mml:mi>T</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mn>1</mml:mn></mml:msub></mml:mrow><mml:mo>)</mml:mo></mml:mrow></mml:mrow></mml:mfrac></mml:mrow></mml:math></disp-formula>
<p>where &#x00394;<italic>B</italic>(<italic>r</italic>) is given in Tesla. This procedure is referred to as <italic>B</italic><sub>0</sub> mapping. It is also very common to represent local magnetic field variations in Hz by means of off-center frequency maps:</p>
<disp-formula id="E11"><label>(11)</label><mml:math id="M117"><mml:mrow><mml:mo>&#x00394;</mml:mo><mml:msub><mml:mi>B</mml:mi><mml:mrow><mml:mi>H</mml:mi><mml:mi>z</mml:mi></mml:mrow></mml:msub><mml:mrow><mml:mo>(</mml:mo><mml:mi>r</mml:mi><mml:mo>)</mml:mo></mml:mrow><mml:mo>=</mml:mo><mml:mfrac><mml:mrow><mml:mi>&#x003D5;</mml:mi><mml:mrow><mml:mo>(</mml:mo><mml:mrow><mml:mi>r</mml:mi><mml:mo>,</mml:mo><mml:mi>T</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>)</mml:mo></mml:mrow><mml:mo>&#x02212;</mml:mo><mml:mi>&#x003D5;</mml:mi><mml:mrow><mml:mo>(</mml:mo><mml:mrow><mml:mi>r</mml:mi><mml:mo>,</mml:mo><mml:mi>T</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mn>1</mml:mn></mml:msub></mml:mrow><mml:mo>)</mml:mo></mml:mrow></mml:mrow><mml:mrow><mml:mn>2</mml:mn><mml:mi>&#x003C0;</mml:mi><mml:mo>&#x000A0;</mml:mo><mml:mrow><mml:mo>(</mml:mo><mml:mrow><mml:mi>T</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mn>2</mml:mn></mml:msub><mml:mo>&#x02212;</mml:mo><mml:mi>T</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mn>1</mml:mn></mml:msub></mml:mrow><mml:mo>)</mml:mo></mml:mrow></mml:mrow></mml:mfrac></mml:mrow></mml:math></disp-formula>
<p><italic>B</italic><sub><italic>0</italic></sub> shimming describes the process of adjusting the main magnetic field <italic>B</italic><sub><italic>0</italic></sub> to improve macroscopic field homogeneity. Active shimming refers to the adjustment of the main magnetic field by making use of dedicated shim coils thereby creating compensatory magnetic fields up to the 5th order of spherical harmonics [<xref ref-type="bibr" rid="B85">85</xref>]. Despite the existence of 5th order shim systems, most scanners provide only shim coils up to 2nd order. Active shimming options include fixed shim current settings or shimming modes based on an individual <italic>B</italic><sub><italic>0</italic></sub> map acquired for a specific subject. For cardiac <italic>B</italic><sub><italic>0</italic></sub> shimming a cardiac triggered field map acquisition is recommended to avoid motion artifacts. Usually a shim volume of interest is defined covering the target anatomy. Ideally the target volume should cover a small region of interest like the heart, to achieve satisfying field homogeneity even when a limited order of shim coils is available. Figure <xref ref-type="fig" rid="F8">8</xref> compares <italic>B</italic><sub>0</sub> homogeneity in the heart of a healthy subject at 7.0 T after applying a volume shim (Figure <xref ref-type="fig" rid="F8">8A</xref>, top), which is focused only on the heart and after applying a global shim (Figure <xref ref-type="fig" rid="F8">8A</xref>, bottom) which includes the entire field of view. Volume selective shimming was found to lead to a significant improvement in macroscopic <italic>B</italic><sub><italic>0</italic></sub> homogeneity vs. global <italic>B</italic><sub><italic>0</italic></sub> shimming (Figure <xref ref-type="fig" rid="F8">8B</xref>) [<xref ref-type="bibr" rid="B39">39</xref>].</p>
<fig id="F8" position="float">
<label>Figure 8</label>
<caption><p>Comparison between volume and global <italic>B</italic><sub>0</sub> shimming in the heart of a healthy volunteer at 7.0 T. <bold>(A)</bold> left: placement of the adjustment volume in a magnitude image. <bold>(A)</bold> right: <italic>B</italic><sub>0</sub> maps with the region of interest (red) and a profile across the heart through the ventricular septum (dashed black line) overlaid. <bold>(B)</bold> Plot of the histogram detailing the distribution of <italic>B</italic><sub>0</sub> in the ROI outlined in the <italic>B</italic><sub>0</sub> maps (top) and plots along the profile in the <italic>B</italic><sub>0</sub> map (bottom) of volume selective (black) and global (red) shim. A clear improvement of field inhomogeneity can be observed after volume selective shimming indicated by a narrowing of the histogram and a flattened <italic>B</italic><sub>0</sub> profile.</p></caption>
<graphic xlink:href="fphy-05-00022-g0008.tif"/>
</fig>
<p>Due to increased susceptibility effects, magnetic field inhomogeneities are pronounced at higher magnetic field strengths [<xref ref-type="bibr" rid="B36">36</xref>] (compare Equation 6). This is often a concern for <inline-formula><mml:math id="M118"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> weighted imaging or <inline-formula><mml:math id="M119"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping at high and ultrahigh magnetic fields. However, by employing dedicated shimming approaches, a mean peak-to-peak off-resonance frequency across the human heart of 80 Hz [<xref ref-type="bibr" rid="B39">39</xref>] was reported at 7.0 T. For the left ventricle a <italic>B</italic><sub>0</sub> peak-to-peak difference of approximately 65 Hz was observed at 7.0 T after volume selective shimming [<xref ref-type="bibr" rid="B39">39</xref>]. These results were obtained with a second order shim system so that the same level of <italic>B</italic><sub>0</sub> uniformity reported here should be achievable with the current and next generation of 7.0 T scanners. The frequency shift across the heart obtained at 7.0 T compares well with previous 3.0 T studies which reported a peak-to-peak off-resonance variation of (176 &#x000B1; 30) Hz over the left ventricle and (121 &#x000B1; 31) Hz over the right ventricle with the use of localized linear and second-order shimming [<xref ref-type="bibr" rid="B86">86</xref>]. The use of an enhanced locally optimized shim algorithm, which is tailored to the geometry of the heart, afforded a reduction of the peak-to-peak frequency variation over the heart from 235 to 86 Hz at 3.0 T [<xref ref-type="bibr" rid="B87">87</xref>]. Another study showed a peak-to-peak off-resonance of (71 &#x000B1; 14) Hz for short axis views acquired at 1.5 T [<xref ref-type="bibr" rid="B88">88</xref>] using global shimming. While dedicated shim routines revealed competitive results at 7.0 T vs. lower magnetic fields strength, the feasibility of using these approaches in a clinical setting remains to be investigated.</p>
<p>The achievement of macroscopic <italic>B</italic><sub><italic>0</italic></sub> homogeneity across the heart at 7.0 T which is competitive with that obtained at lower magnetic field strengths provides encouragement to pursue susceptibility-based myocardial <inline-formula><mml:math id="M120"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping at ultrahigh fields. Yet, with the arrival of CINE <inline-formula><mml:math id="M121"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping techniques enabled by 7.0 T [<xref ref-type="bibr" rid="B39">39</xref>], also temporal <italic>B</italic><sub>0</sub> fluctuations across the cardiac cycle and their implications on <inline-formula><mml:math id="M122"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> need to be considered for a meaningful interpretation of dynamic <inline-formula><mml:math id="M123"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>-weighted acquisitions. Temporal <italic>B</italic><sub>0</sub> variation across the cardiac cycle was reported to be negligible at 1.5 T [<xref ref-type="bibr" rid="B89">89</xref>], but due to the increase of susceptibility effects at ultrahigh fields further investigations of this potential confounder were required at 7.0 T. It should be noted that <inline-formula><mml:math id="M124"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>-weighted contrast is determined by magnetic field gradients rather than absolute magnetic field strength, thus it is essential to investigate the change of these gradients over the cardiac cycle. This was done at 7.0 T by assessing macroscopic <italic>B</italic><sub><italic>0</italic></sub> gradients across the cardiac cycle in the heart of healthy volunteers together with high temporal and spatial resolution <inline-formula><mml:math id="M125"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> maps [<xref ref-type="bibr" rid="B84">84</xref>, <xref ref-type="bibr" rid="B90">90</xref>]. <inline-formula><mml:math id="M126"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>-weighted series of short-axis views were acquired using a MEGRE CINE approach (Figure <xref ref-type="fig" rid="F9">9A</xref>, top) for cardiac phase resolved <italic>B</italic><sub>0</sub> and <inline-formula><mml:math id="M127"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping. Temporally-resolved <italic>B</italic><sub>0</sub> maps of the heart were calculated (Figure <xref ref-type="fig" rid="F9">9A</xref>, middle). Macroscopic intra-voxel field gradients were determined for each cardiac phase and their fluctuations were analyzed across the cardiac cycle. The septal in-plane gradients were found to be significantly larger compared to through-plane gradients within a voxel [with a mean in-plane field dispersion of (2.5 &#x000B1; 0.2) Hz/mm against the a mean through-plane field dispersion of (0.4 &#x000B1; 0.1) Hz/mm] [<xref ref-type="bibr" rid="B91">91</xref>].</p>
<fig id="F9" position="float">
<label>Figure 9</label>
<caption><p>Spatial and temporal variation of macroscopic intra-voxel <italic>B</italic><sub>0</sub> gradients in the <italic>in vivo</italic> human heart. <bold>(A)</bold> Magnitude images of a short-axis view (top), in-plane macroscopic <italic>B</italic><sub>0</sub> maps (middle) and intra-voxel macroscopic <italic>B</italic><sub>0</sub> gradient maps (bottom) over the cardiac cycle. <bold>(B)</bold> Mean septal <inline-formula><mml:math id="M128"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> (blue), intra-voxel <italic>B</italic><sub>0</sub> gradient (black) and estimated &#x00394;<inline-formula><mml:math id="M129"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> caused by this <italic>B</italic><sub>0</sub> gradient (red) over the cardiac cycle, averaged among a group of healthy volunteers. Temporal macroscopic magnetic field changes over the cardiac cycle are minor regarding their effects on <inline-formula><mml:math id="M130"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> (from Huelnhagen et al. [<xref ref-type="bibr" rid="B84">84</xref>] with permission from John Wiley and Sons).</p></caption>
<graphic xlink:href="fphy-05-00022-g0009.tif"/>
</fig>
<p>In order to evaluate how these <italic>B</italic><sub><italic>0</italic></sub> gradients affect <inline-formula><mml:math id="M131"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> measurements, the <italic>B</italic><sub><italic>0</italic></sub> gradient-induced change of <inline-formula><mml:math id="M132"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> represented as &#x00394;<inline-formula><mml:math id="M133"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> was estimated [<xref ref-type="bibr" rid="B84">84</xref>, <xref ref-type="bibr" rid="B91">91</xref>]. Figure <xref ref-type="fig" rid="F9">9B</xref> shows the plot of mean septal <inline-formula><mml:math id="M134"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, intra-voxel <italic>B</italic><sub><italic>0</italic></sub> gradients and estimated gradient-induced &#x00394;<inline-formula><mml:math id="M135"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> over the cardiac cycle averaged over a group of healthy subjects. The mean septal <inline-formula><mml:math id="M136"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> per cardiac phase was found to vary over the cardiac cycle in a range of approximately 23% of the total mean <inline-formula><mml:math id="M137"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> for all phases. Yet, the temporal range of mean &#x00394;<inline-formula><mml:math id="M138"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> induced by the calculated intra-voxel macroscopic <italic>B</italic><sub><italic>0</italic></sub> gradients represented only a 5% change of total mean <inline-formula><mml:math id="M139"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>. The remaining 18% were suggested to reflect microscopic <italic>B</italic><sub><italic>0</italic></sub> gradient changes (potentially caused by physiological events) rather than macroscopic field inhomogeneities [<xref ref-type="bibr" rid="B84">84</xref>, <xref ref-type="bibr" rid="B91">91</xref>].</p>
<p>In summary it can be concluded that if careful shimming is applied, macroscopic magnetic field inhomogeneities are not of concern for myocardial <inline-formula><mml:math id="M140"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping even at a magnetic field strength as high as 7.0 T. Also dynamic <italic>B</italic><sub><italic>0</italic></sub> fluctuations across the cardiac cycle can be considered negligible in the ventricular septum. These findings represent an essential prerequisite for meaningful interpretation of myocardial <inline-formula><mml:math id="M141"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> and its dynamics across the cardiac cycle.</p>
</sec>
<sec>
<title>Data post-processing</title>
<p>The effective transverse relaxation time <inline-formula><mml:math id="M142"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> can be estimated by fitting an exponential function to a series of gradient echo images with different <inline-formula><mml:math id="M143"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> weighting, i.e., different echo times (compare Equations 3, 4; Figure <xref ref-type="fig" rid="F1">1</xref>). A common way of calculating such a fit by avoiding non-linear fitting procedures, is to calculate the natural logarithm of the acquired signal intensities and apply a least squares linear fit to the resulting data. This procedure is fast and produces the best solution to represent the linearized data in a least squares sense. Further to this, non-linear fitting approaches which can be applied directly to the measured data are available. The algorithms employ non-linear models in conjunction with optimization algorithms like Levenberg-Marquardt or Simplex [<xref ref-type="bibr" rid="B92">92</xref>]. Iterative non-linear fitting algorithms can provide improved fitting accuracy, but can be prone to careful initialization. Fast linear fitting can be used to initialize non-linear fitting algorithms leading to increased robustness and faster convergence. Irrespective of the kind of employed fitting procedure, care should be taken for voxels with intensities being at the noise level and hence potentially deteriorating the fit quality. Low SNR is a common problem particularly for myocardial <inline-formula><mml:math id="M144"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping where acquisition times are often limited by the tolerable breath hold time. Such voxels should either be excluded from fitting&#x02014;a procedure referred to as truncation&#x02014;or included in the fit model as a constant noise term.</p>
<p>Most commercial MR systems support exponential fitting algorithms as part of the systems&#x00027; software, but using customized fitting routines is often beneficial for research. First, it is often unclear what model or fitting approach is used by commercial software and how good the fit quality was, i.e., how well the fit describes the measured data. Measures like the coefficient of determination R<sup>2</sup> or the standard deviation of the <inline-formula><mml:math id="M145"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> fit [<xref ref-type="bibr" rid="B93">93</xref>] should be used to evaluate the reliability of the results. Taking fitting results for granted without considering fit quality may lead to wrong results and eventually wrong conclusions. Second, tailored fitting procedures offer the freedom to select the most appropriate fit model, optimization approach, truncation threshold, etc. for the particular research question. Depending on the kind of application, it may for example make sense to use a bi-exponential or multi-exponential model instead of a mono-exponential approach.</p>
<p>In contrast to qualitative signal intensity images, relaxation maps like <inline-formula><mml:math id="M146"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> maps offer the advantage of providing quantitative, comparable results. Yet, effects like <italic>B</italic><sub><italic>0</italic></sub> inhomogeneities or signal noise can impair the assessment of <inline-formula><mml:math id="M147"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> and lead to wrong results. Dedicated <italic>B</italic><sub><italic>0</italic></sub> shimming approaches help to mitigate the impact of macroscopic magnetic field inhomogeneities. A reduction in voxel size can further reduce the influence of <italic>B</italic><sub><italic>0</italic></sub> gradients on <inline-formula><mml:math id="M148"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> (Figure <xref ref-type="fig" rid="F5">5B</xref>). Yet, reducing voxel size results in an SNR loss, which can induce poor fit quality offsetting the benefit of the smaller voxel size. While a reduction in SNR might be counteracted by signal averaging and increasing acquisition times in static acquisition situations (e.g., MRI of the brain), it is often not feasible in cardiac applications, where acquisitions need to be synchronized with the cardiac cycle and where it is common to utilize breath held conditions constraining the viable window of data acquisition to few seconds. This issue is even further pronounced in patients suffering from cardiac diseases and for acquisitions at high spatial or temporal resolution such as CINE <inline-formula><mml:math id="M149"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping.</p>
<p>Image de-noising presents a viable solution to address this constraint and allows the use of small voxel sizes while still achieving acceptable fit quality. Powerful de-noising approaches like non-local means filtering [<xref ref-type="bibr" rid="B94">94</xref>] are readily available and can greatly improve SNR with minimal loss of information. De-noising of the <inline-formula><mml:math id="M150"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> maps is not recommended, because low fit quality of fitting noisy data can result in large <inline-formula><mml:math id="M151"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> errors that might even be enlarged or spread out by filtering. Also algorithms that estimate the noise level from the provided data will fail if presented with <inline-formula><mml:math id="M152"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> maps. Filtering of the magnitude images prior to fitting instead represents a robust way of improving fit quality and has been shown to increase <inline-formula><mml:math id="M153"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> fitting accuracy and precision [<xref ref-type="bibr" rid="B84">84</xref>, <xref ref-type="bibr" rid="B95">95</xref>, <xref ref-type="bibr" rid="B96">96</xref>] without the risk of introducing large errors. Figure <xref ref-type="fig" rid="F10">10</xref> illustrates an example of how <inline-formula><mml:math id="M154"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping can benefit from noise filtering. Here a 30% reduction of <inline-formula><mml:math id="M155"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> fit standard deviation was achieved by noise filtering. For applications where SNR is limited such as myocardial <inline-formula><mml:math id="M156"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping, image de-noising approaches provide a good solution to improve mapping results.</p>
<fig id="F10" position="float">
<label>Figure 10</label>
<caption><p>Impact of spatially adaptive non-local means (SANLM) noise filtering on <inline-formula><mml:math id="M157"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> maps of a mid-ventricular short axis view of the heart. Left: Original and SANLM filtered signal magnitude images of the first echo (TE &#x0003D; 2.04 ms) of a series of multi-echo gradient echo images. Center: Corresponding <inline-formula><mml:math id="M158"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> maps. Right: <inline-formula><mml:math id="M159"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> standard deviation maps illustrating the precision of the <inline-formula><mml:math id="M160"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> maps. By applying the noise filter, an average decrease in <inline-formula><mml:math id="M161"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> fit standard deviation of about 30% in the left ventricular myocardium was achieved.</p></caption>
<graphic xlink:href="fphy-05-00022-g0010.tif"/>
</fig>
</sec>
</sec>
<sec id="s3">
<title>Insights from <italic>in vivo</italic> human myocardial <inline-formula><mml:math id="M162"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping at ultrahigh fields</title>
<p>The technological and methodological developments in ultrahigh field CMR outlined above, permit for the first time the <italic>in vivo</italic> assessment of temporal myocardial <inline-formula><mml:math id="M163"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> changes across the cardiac cycle. Initial studies have applied these advances to gain first insights from using this technique in healthy volunteers and patients suffering from cardiovascular diseases to investigate their feasibility and potential [<xref ref-type="bibr" rid="B39">39</xref>, <xref ref-type="bibr" rid="B84">84</xref>].</p>
<sec>
<title>CINE myocardial <inline-formula><mml:math id="M164"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping in healthy subjects</title>
<p>A first study systematically investigating the temporal changes of myocardial <inline-formula><mml:math id="M165"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> across the cardiac cycle in healthy subjects at 7.0 T was published in 2016 [<xref ref-type="bibr" rid="B84">84</xref>]. The authors analyzed the time course of myocardial <inline-formula><mml:math id="M166"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> throughout the cardiac cycle along with basic myocardial morphology, i.e., ventricular septal wall thickness and inner left ventricular radius as potential confounders of <inline-formula><mml:math id="M167"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>. The results demonstrated that myocardial <inline-formula><mml:math id="M168"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> obtained correlates linearly with the myocardial wall thickness [<xref ref-type="bibr" rid="B84">84</xref>], (Figure <xref ref-type="fig" rid="F11">11</xref>). The same study also showed that <inline-formula><mml:math id="M169"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> in the ventricular septum changes periodically across the cardiac cycle [<xref ref-type="bibr" rid="B84">84</xref>]. It increases in systole&#x02014;the part of the cardiac cycle when the ventricles contract&#x02014;and decreases in diastole&#x02014;the part of the cardiac cycle when the heart relaxes and refills with blood (Figure <xref ref-type="fig" rid="F12">12A</xref>). The mean systole to diastole <inline-formula><mml:math id="M170"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> ratio was found to be approximately 1.1. Despite the numerous factors affecting <inline-formula><mml:math id="M171"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> such as blood volume fraction, hematocrit etc., myocardial <inline-formula><mml:math id="M172"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> is still often regarded as surrogate for tissue oxygenation. Interpreting <inline-formula><mml:math id="M173"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> to reflect tissue oxygenation, the observed systolic <inline-formula><mml:math id="M174"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> increase would imply an increase in left myocardial oxygenation during systole. This is contrary to physiological knowledge. Instead, changes in myocardial blood volume fraction induced by variations in blood pressure and resulting myocardial wall stress are believed to be responsible for the observed cyclic <inline-formula><mml:math id="M175"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> changes [<xref ref-type="bibr" rid="B84">84</xref>]. The contraction of the heart muscle compresses the intramyocardial vasculature such that inflow of arterial blood is interrupted while deoxygenated blood is squeezed out of the myocardium toward the venous coronary sinus [<xref ref-type="bibr" rid="B97">97</xref>&#x02013;<xref ref-type="bibr" rid="B100">100</xref>] (Figure <xref ref-type="fig" rid="F12">12B</xref>). The major systolic decrease in blood volume fraction in the myocardium reduces the amount of deoxygenated hemoglobin per tissue volume, thereby increasing&#x02014;instead of lowering&#x02014;<inline-formula><mml:math id="M176"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> during systole. Previous studies of skeletal muscle have also linked <inline-formula><mml:math id="M177"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> changes to alterations in tissue pH and resulting changes of the tissue water content and distribution after exercise [<xref ref-type="bibr" rid="B101">101</xref>, <xref ref-type="bibr" rid="B102">102</xref>]. These studies have examined baseline and post-exercise conditions, which are difficult to compare with the heart which is constantly exercising. Still, <italic>T</italic><sub>2</sub> changes driven by tissue water content and distribution changes should be considered as a potential source of <inline-formula><mml:math id="M178"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> changes also in the heart. The hypothesis, that the observed periodic <inline-formula><mml:math id="M179"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> changes could be induced by macroscopic <italic>B</italic><sub><italic>0</italic></sub> field variations induced by changes in bulk morphology between systole and diastole, was carefully investigated but not confirmed. Both, <italic>in silico</italic> magneto static simulations and <italic>in vivo</italic> temporally resolved <italic>B</italic><sub><italic>0</italic></sub> mapping, showed negligible impact of cardiac morphology on the macroscopic <italic>B</italic><sub><italic>0</italic></sub> field in the ventricular septum and hence <inline-formula><mml:math id="M180"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> [<xref ref-type="bibr" rid="B84">84</xref>].</p>
<fig id="F11" position="float">
<label>Figure 11</label>
<caption><p>Relationship of mean ventricular septal wall thickness and mean septal <inline-formula><mml:math id="M181"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> in a group of healthy volunteers at 7.0 T. One data point corresponds to one cardiac phase. Septal wall thickness and <inline-formula><mml:math id="M182"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> are linearly correlated. The result of linear regression is plotted in red. Error bars indicate SEM.</p></caption>
<graphic xlink:href="fphy-05-00022-g0011.tif"/>
</fig>
<fig id="F12" position="float">
<label>Figure 12</label>
<caption><p>Results of temporally resolved myocardial <inline-formula><mml:math id="M183"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping in healthy volunteers at 7.0 T. <bold>(A)</bold> Course of mean septal <inline-formula><mml:math id="M184"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, wall thickness and LV inner radius plotted over the cardiac cycle averaged for a group of healthy volunteers. Error bars indicate SD. Myocardial <inline-formula><mml:math id="M185"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> changes periodically across the cardiac cycle increasing in systole and decreasing in diastole. <bold>(B)</bold> The periodic <inline-formula><mml:math id="M186"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> changes can be explained by cyclic variations of myocardial blood volume fraction related to differences in blood pressure and myocardial wall stress. The massive pressure increase in the left ventricle in the beginning of systole results in high myocardial wall stress compressing the myocardial vessels leading to a reduced blood supply to the myocardium while blood contained in the tissue is squeezed out. The resulting reduced myocardial blood volume fraction explains the systolic <inline-formula><mml:math id="M187"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> increase, which cannot be explained by increased oxygenation.</p></caption>
<graphic xlink:href="fphy-05-00022-g0012.tif"/>
</fig>
</sec>
<sec>
<title>Myocardial <inline-formula><mml:math id="M188"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping in patients with cardiovascular diseases</title>
<p>Besides the application of myocardial <inline-formula><mml:math id="M189"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping at ultrahigh magnetic fields in healthy volunteers, first investigations were carried out to explore the potential of the technique to distinguish between healthy and pathologic myocardium. These early UHF-CMR studies focused on <inline-formula><mml:math id="M190"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping in patients with hypertrophic cardiomyopathy (HCM). HCM is the most common inherited cardiac disease affecting about 0.2&#x02013;0.5% of the general population [<xref ref-type="bibr" rid="B103">103</xref>, <xref ref-type="bibr" rid="B104">104</xref>]. The disease is characterized by an increase in myocardial wall thickness related to myocyte hypertrophy, microstructural changes like myocardial disarray, fibrosis and microvascular dysfunction. HCM patients often remain asymptomatic, but the disease can have a severe outcome in a subgroup of patients where it may cause heart failure and sudden unexpected cardiac death (SCD) in any age group. SCD and has been reported to affect about 6% of HCM patients within a mean follow up time of (8 &#x000B1; 7) years [<xref ref-type="bibr" rid="B105">105</xref>]. This renders risk stratification vital for HCM patients. CMR plays an important role in the diagnosis and prognosis of HCM [<xref ref-type="bibr" rid="B106">106</xref>]. While a number of SCD risk factors in HCM have been identified such as degree of hypertrophy or presence of fibrosis the task remains challenging [<xref ref-type="bibr" rid="B107">107</xref>]. Consequently, basic research efforts and clinical science activities are required to better characterize HCM patient populations and to direct appropriate therapies to those at risk.</p>
<p>Based on the structural and physiologic changes, differences in myocardial <inline-formula><mml:math id="M191"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> were hypothesized in HCM patients compared to healthy controls. This hypothesis was investigated using high spatiotemporal resolution <inline-formula><mml:math id="M192"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping at 7.0 T (Figure <xref ref-type="fig" rid="F13">13</xref>). It was found that septal <inline-formula><mml:math id="M193"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> is significantly increased in HCM with mean septal <inline-formula><mml:math id="M194"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> being (17.5 &#x000B1; 1.4) ms in a cohort of HCM patients compared to (13.7 &#x000B1; 1.1) ms in a group of gender, age and body mass index matched healthy controls. While variations of myocardial <inline-formula><mml:math id="M195"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> across the cardiac cycle have been attributed to changes in myocardial blood volume fraction rather than changes in tissue oxygenation [<xref ref-type="bibr" rid="B84">84</xref>], two main factors are assumed to cause the observed overall <inline-formula><mml:math id="M196"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> increase in HCM. Improved tissue oxygenation in the diseased myocardium in the case of HCM is unlikely. Instead, <italic>T</italic><sub>2</sub> has been reported to be elevated in HCM [<xref ref-type="bibr" rid="B108">108</xref>] related to presence of inflammation and edema. A <italic>T</italic><sub>2</sub> increase would also result in increased <inline-formula><mml:math id="M197"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> as seen from Equation (1). Further to this, reduced myocardial perfusion and ischemia are common in HCM [<xref ref-type="bibr" rid="B109">109</xref>], effectively reducing the tissue blood volume fraction resulting in a <inline-formula><mml:math id="M198"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> increase as suggested by Equation (5). These conditions are also associated with a higher risk for a poor outcome in HCM patients [<xref ref-type="bibr" rid="B110">110</xref>]. With this in mind it is fair to conclude that myocardial <inline-formula><mml:math id="M199"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping could be beneficial for a better understanding of cardiac (patho)physiology <italic>in vivo</italic> with the ultimate goal to support risk stratification in HCM.</p>
<fig id="F13" position="float">
<label>Figure 13</label>
<caption><p>Cardiac phase resolved myocardial <inline-formula><mml:math id="M200"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping in healthy volunteers and HCM patients. <bold>(A)</bold> Temporally resolved myocardial <inline-formula><mml:math id="M201"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> maps of a short axis view of a healthy control (top) and an HCM patient (bottom), (5 out of 20 phases shown). Spatial resolution (1.1 &#x000D7; 1.1 &#x000D7; 4.0) mm<sup>3</sup>. <inline-formula><mml:math id="M202"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> variations can be observed across the cardiac cycle. <bold>(B)</bold> Course of mean septal <inline-formula><mml:math id="M203"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, wall thickness and inner LV radius plotted over the cardiac cycle averaged for groups of healthy controls (left) and HCM patients (right). Relative cardiac phase 0 indicates the beginning of systole. <inline-formula><mml:math id="M204"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> changes periodically over the cardiac cycle increasing in systole and decreasing in diastole in both, healthy controls and HCM patients, but is significantly elevated in HCM patients.</p></caption>
<graphic xlink:href="fphy-05-00022-g0013.tif"/>
</fig>
</sec>
</sec>
<sec id="s4">
<title>Conclusion and future directions</title>
<p>The progress in myocardial <inline-formula><mml:math id="M205"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping at ultrahigh magnetic fields is promising [<xref ref-type="bibr" rid="B111">111</xref>&#x02013;<xref ref-type="bibr" rid="B113">113</xref>]. Yet, there are still a number of questions to be answered and the clinical benefit remains to be carefully investigated. This requires further efforts to tackle unsolved problems and unmet needs standing in the way <italic>en route</italic> to broader clinical studies. For example, the relatively long breath hold times required for the acquisition of high spatiotemporal resolution <inline-formula><mml:math id="M206"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> maps constitute a challenge particularly in cardiac patients. Free breathing acquisition techniques could offset this constraint permitting broader application and full 3D heart coverage. This would also help to further investigate the effect of through-plane motion. Acquisition approaches like simultaneous multi-slice excitation can be used to reduce scan times while multi-channel transmit systems can be employed to balance excitation field homogeneity and RF power deposition constraints [<xref ref-type="bibr" rid="B114">114</xref>, <xref ref-type="bibr" rid="B115">115</xref>].</p>
<p>Based on the multifaceted contributions of physiological parameters on <inline-formula><mml:math id="M207"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> research will not stop at just mapping myocardial <inline-formula><mml:math id="M208"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>. Tailored acquisition schemes, data post-processing, analysis and interpretation will allow exploiting the wealth of information encoded into <inline-formula><mml:math id="M209"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>. For example high spatial resolution <inline-formula><mml:math id="M210"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping facilitated by ultrahigh magnetic field strengths might be beneficial to gain a better insight into the myocardial microstructure <italic>in vivo</italic> with the ultimate goal to visualize myocardial fibers or to examine their helical angulation, since the susceptibility effects depend on the orientation of blood filled capillaries with regard to the external magnetic field [<xref ref-type="bibr" rid="B116">116</xref>]. Myocardial fiber tracking using <inline-formula><mml:math id="M211"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping holds the promise to be less sensitive to bulk motion than diffusion-weighted MR of the myocardium [<xref ref-type="bibr" rid="B117">117</xref>, <xref ref-type="bibr" rid="B118">118</xref>]. The increased susceptibility contrast available at 7.0 T could be exploited to quantitatively study iron accumulation in the heart with high sensitivity and spatial resolution superior to what can be achieved at 1.5 and 3.0 T. This requires the determination of norm values for healthy myocardial <inline-formula><mml:math id="M212"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> at 7.0 T as a mandatory precursor to broader clinical studies.</p>
<p>At the same time small animal studies employing cardiac disease models can provide a valuable contribution to understanding the underlying biophysical principles and (patho)physiological contrast mechanisms governing <inline-formula><mml:math id="M213"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>. Unlike human studies they offer the unique possibility to directly compare <italic>in vivo</italic> findings by MRI with <italic>ex vivo</italic> histology, the gold standard for tissue characterization. Recent such studies indicate that <inline-formula><mml:math id="M214"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> might provide not only an alternative for detection of both replacement and diffuse fibrosis without the need for exogenous contrast agents, but also has potential to distinguish the two by means of relaxation time changes induced by the presence of collagen and other fibrotic elements in the extracellular matrix [<xref ref-type="bibr" rid="B17">17</xref>, <xref ref-type="bibr" rid="B18">18</xref>]. This could provide new diagnostic means to a large group of patients excluded from contrast agent injections due to renal insufficiencies. A study employing a mouse myocardial ischemia/reperfusion model has provided first insights into <italic>in vivo</italic> quantification of <inline-formula><mml:math id="M215"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> changes in the mouse myocardium in relation to tissue damage [<xref ref-type="bibr" rid="B16">16</xref>]. Local decrease of <inline-formula><mml:math id="M216"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> was found in the infarct zone and associated with deposition of collagen. The authors describe that <inline-formula><mml:math id="M217"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> varies dynamically during infarct development suggesting that it may be used to discriminate between acute and chronic infarctions. Taken together, by concordance the findings between human studies and cardiac disease models of small rodents will provide stronger evidence for fundamental understandings of myocyte biology, and cardiac performance with the goal to provide a more accurate diagnosis and risk stratification. Thanks to the sensitivity gain at 7.0 T the spatial fidelity feasible for <italic>T</italic><sub>2</sub><sup>&#x0002A;</sup> mapping in humans approaches the relative anatomical spatial resolution&#x02014;in terms of number of voxels with respect to anatomy&#x02014;demonstrated for cardiac imaging in animal models [<xref ref-type="bibr" rid="B119">119</xref>, <xref ref-type="bibr" rid="B120">120</xref>]. This achievement is translatable into opportunities for discovery and translational research.</p>
<p>The ability to probe for changes in myocardial tissue oxygenation using <inline-formula><mml:math id="M218"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> sensitized imaging/mapping offers the potential to address some of the spatial and temporal resolution constraints of conventional first pass perfusion imaging and holds the promise to obviate the need for exogenous contrast agents. Since microscopic susceptibility increases with field strength, thus making oxygenation sensitivity due to ischemic (patho) physiology more pronounced, <inline-formula><mml:math id="M219"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping at 7.0 T might be beneficial to address some of the BOLD sensitivity constraints reported for the assessment of regional myocardial oxygenation changes in the presence of coronary artery stenosis [<xref ref-type="bibr" rid="B121">121</xref>] or for the characterization of vasodilator-induced changes of myocardial oxygenation at 1.5 T and at 3.0 T [<xref ref-type="bibr" rid="B10">10</xref>].</p>
<p>The pace of discovery is exciting and a powerful motivator to transfer the lessons learned from <inline-formula><mml:math id="M220"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping research at 7.0 T into the clinical scenario. These efforts are fueled by the quest for advancing the capabilities of quantitative MRI and the wish to overcome the need of exogenous contrast agent injections. The requirements of <inline-formula><mml:math id="M221"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping at 7.0 T are likely to pave the way for further advances in MR technology and MR systems design. With appropriate multi transmit systems offering more than 16 transmit channels each providing at least 4 kW peak power, an optimistically-inclined scientist might envision the implementation of high density transceiver arrays with 64 and more elements with the ultimate goal to break ground for a many element upper torso or even a body coil array. This vision continues to motivate new research on integrated multi-channel transmission systems [<xref ref-type="bibr" rid="B122">122</xref>], on novel RF pulse design, on RF coil design together with explorations into ideal current patterns yielding optimal signal-to-noise-ratio for UHF-CMR [<xref ref-type="bibr" rid="B123">123</xref>]. Perhaps another development is the move toward myocardial <inline-formula><mml:math id="M222"><mml:mrow><mml:msup><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mn>2</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> mapping using reduced field of views zoomed into the target anatomy enabled by spatially selective excitation techniques which put the capabilities of parallel transmission technology to good use. With more than 45,000 examinations already performed at 7.0 T, the reasons for employing UHF-MR in translational research and for moving UHF-MR into clinical applications are more compelling than ever. This provides strong motivation to put further weight behind pushing the solution of the many remaining problems. As an important step toward this goal a system manufacturer has recently filed for FDA clearing for the clinical use of a 7.0 T system. With this development we can expect more pioneering research institutions, university hospitals and large clinics to become early adopters of CMR at 7.0 T and start harvesting knowledge and know-how that will benefit clinical applications.</p>
</sec>
<sec id="s5">
<title>Ethics statement</title>
<p><italic>In vivo</italic> studies of which data is presented in this work were carried out in accordance with the guidelines of the local ethical committee (registration number DE/CA73/5550/09, Landesamt f&#x000FC;r Arbeitsschutz, Gesundheitsschutz und technische Sicherheit, Berlin, Germany) with written informed consent from all subjects in compliance with the local institutional review board guidelines. All subjects gave written informed consent in accordance with the Declaration of Helsinki. The protocols were approved by the local ethical committee.</p>
</sec>
<sec id="s6">
<title>Author contributions</title>
<p>TH and TN wrote the manuscript with help from KP, MK, and TS.</p>
<sec>
<title>Conflict of interest statement</title>
<p>TN is founder and CEO of MRI.TOOLS GmbH, Berlin, Germany. The reviewer AIS and handling Editor declared their shared affiliation, and the handling Editor states that the process nevertheless met the standards of a fair and objective review. The other authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
</sec>
</body>
<back>
<ack>
<p>The authors wish to acknowledge the team at the Berlin Ultrahigh Field Facility (B.U.F.F.) at the Max-Delbrueck Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany; Jeanette Schulz-Menger from the working group for Cardiac Magnetic Resonance, Charite&#x00027;, Berlin, Germany; Peter Kellman (National Institutes of Health, NHLBI, Laboratory of Cardiac Energetics, Bethesda, USA); who kindly contributed examples of their pioneering work or other valuable assistance.</p>
</ack>
<ref-list>
<title>References</title>
<ref id="B1">
<label>1.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>von Knobelsdorff-Brenkenhoff</surname> <given-names>F</given-names></name> <name><surname>Schulz-Menger</surname> <given-names>J</given-names></name></person-group>. <article-title>Role of cardiovascular magnetic resonance in the guidelines of the European Society of Cardiology</article-title>. <source>J Cardiovasc Magn Reson.</source> (<year>2016</year>) <volume>18</volume>:<fpage>6</fpage>. <pub-id pub-id-type="doi">10.1186/s12968-016-0225-6</pub-id><pub-id pub-id-type="pmid">26800662</pub-id></citation></ref>
<ref id="B2">
<label>2.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Captur</surname> <given-names>G</given-names></name> <name><surname>Manisty</surname> <given-names>C</given-names></name> <name><surname>Moon</surname> <given-names>JC</given-names></name></person-group>. <article-title>Cardiac MRI evaluation of myocardial disease</article-title>. <source>Heart</source> (<year>2016</year>) <volume>102</volume>:<fpage>1429</fpage>&#x02013;<lpage>35</lpage>. <pub-id pub-id-type="doi">10.1136/heartjnl-2015-309077</pub-id><pub-id pub-id-type="pmid">27354273</pub-id></citation></ref>
<ref id="B3">
<label>3.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ogawa</surname> <given-names>S</given-names></name> <name><surname>Menon</surname> <given-names>RS</given-names></name> <name><surname>Tank</surname> <given-names>DW</given-names></name> <name><surname>Kim</surname> <given-names>SG</given-names></name> <name><surname>Merkle</surname> <given-names>H</given-names></name> <name><surname>Ellermann</surname> <given-names>JM</given-names></name> <etal/></person-group>. <article-title>Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical model</article-title>. <source>Biophys J.</source> (<year>1993</year>) <volume>64</volume>:<fpage>803</fpage>&#x02013;<lpage>12</lpage>. <pub-id pub-id-type="doi">10.1016/S0006-3495(93)81441-3</pub-id><pub-id pub-id-type="pmid">8386018</pub-id></citation></ref>
<ref id="B4">
<label>4.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wacker</surname> <given-names>CM</given-names></name> <name><surname>Hartlep</surname> <given-names>AW</given-names></name> <name><surname>Pfleger</surname> <given-names>S</given-names></name> <name><surname>Schad</surname> <given-names>LR</given-names></name> <name><surname>Ertl</surname> <given-names>G</given-names></name> <name><surname>Bauer</surname> <given-names>WR</given-names></name></person-group>. <article-title>Susceptibility-sensitive magnetic resonance imaging detects human myocardium supplied by a stenotic coronary artery without a contrast agent</article-title>. <source>J Am Coll Cardiol.</source> (<year>2003</year>) <volume>41</volume>:<fpage>834</fpage>&#x02013;<lpage>40</lpage>. <pub-id pub-id-type="doi">10.1016/S0735-1097(02)02931-5</pub-id><pub-id pub-id-type="pmid">12628730</pub-id></citation></ref>
<ref id="B5">
<label>5.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Friedrich</surname> <given-names>M</given-names></name> <name><surname>Niendorf</surname> <given-names>T</given-names></name> <name><surname>Schulz-Menger</surname> <given-names>J</given-names></name></person-group>. <article-title>Blood oxygen level-dependent magnetic resonance imaging in patients with stress-induced angina</article-title>. <source>ACC Curr J Rev.</source> (<year>2004</year>) <volume>13</volume>:<fpage>30</fpage>. <pub-id pub-id-type="doi">10.1016/j.accreview.2004.03.013</pub-id></citation></ref>
<ref id="B6">
<label>6.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jahnke</surname> <given-names>C</given-names></name> <name><surname>Gebker</surname> <given-names>R</given-names></name> <name><surname>Manka</surname> <given-names>R</given-names></name> <name><surname>Schnackenburg</surname> <given-names>B</given-names></name> <name><surname>Fleck</surname> <given-names>E</given-names></name> <name><surname>Paetsch</surname> <given-names>I</given-names></name></person-group>. <article-title>Navigator-gated 3D blood oxygen level&#x02013;dependent CMR at 3</article-title>.0-T for detection of stress-induced myocardial ischemic reactions. <source>JACC Cardiovasc Imaging</source> (<year>2010</year>) <volume>3</volume>:<fpage>375</fpage>&#x02013;<lpage>84</lpage>. <pub-id pub-id-type="doi">10.1016/j.jcmg.2009.12.008</pub-id><pub-id pub-id-type="pmid">20394899</pub-id></citation></ref>
<ref id="B7">
<label>7.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Karamitsos</surname> <given-names>TD</given-names></name> <name><surname>Leccisotti</surname> <given-names>L</given-names></name> <name><surname>Arnold</surname> <given-names>JR</given-names></name> <name><surname>Recio-Mayoral</surname> <given-names>A</given-names></name> <name><surname>Bhamra-Ariza</surname> <given-names>P</given-names></name> <name><surname>Howells</surname> <given-names>RK</given-names></name> <etal/></person-group>. <article-title>Relationship between regional myocardial oxygenation and perfusion in patients with coronary artery disease insights from cardiovascular magnetic resonance and positron emission tomography</article-title>. <source>Circ Cardiovasc Imaging</source> (<year>2010</year>) <volume>3</volume>:<fpage>32</fpage>&#x02013;<lpage>40</lpage>. <pub-id pub-id-type="doi">10.1161/CIRCIMAGING.109.860148</pub-id><pub-id pub-id-type="pmid">19920032</pub-id></citation></ref>
<ref id="B8">
<label>8.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tsaftaris</surname> <given-names>SA</given-names></name> <name><surname>Tang</surname> <given-names>R</given-names></name> <name><surname>Zhou</surname> <given-names>X</given-names></name> <name><surname>Li</surname> <given-names>D</given-names></name> <name><surname>Dharmakumar</surname> <given-names>R</given-names></name></person-group>. <article-title>Ischemic extent as a biomarker for characterizing severity of coronary artery stenosis with blood oxygen-sensitive MRI</article-title>. <source>J Magn Reson Imaging</source> (<year>2012</year>) <volume>35</volume>:<fpage>1338</fpage>&#x02013;<lpage>48</lpage>. <pub-id pub-id-type="doi">10.1002/jmri.23577</pub-id><pub-id pub-id-type="pmid">22246681</pub-id></citation></ref>
<ref id="B9">
<label>9.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wacker</surname> <given-names>CM</given-names></name> <name><surname>Bock</surname> <given-names>M</given-names></name> <name><surname>Hartlep</surname> <given-names>AW</given-names></name> <name><surname>Beck</surname> <given-names>G</given-names></name> <name><surname>van Kaick</surname> <given-names>G</given-names></name> <name><surname>Ertl</surname> <given-names>G</given-names></name> <etal/></person-group>. <article-title>Changes in myocardial oxygenation and perfusion under pharmacological stress with dipyridamole: assessment using T<sup>&#x0002A;</sup>2 and T1 measurements</article-title>. <source>Magn Reson Med.</source> (<year>1999</year>) <volume>41</volume>:<fpage>686</fpage>&#x02013;<lpage>95</lpage>. <pub-id pub-id-type="pmid">10332843</pub-id></citation></ref>
<ref id="B10">
<label>10.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Vohringer</surname> <given-names>M</given-names></name> <name><surname>Flewitt</surname> <given-names>JA</given-names></name> <name><surname>Green</surname> <given-names>JD</given-names></name> <name><surname>Dharmakumar</surname> <given-names>R</given-names></name> <name><surname>Wang</surname> <given-names>J</given-names> <suffix>Jr.</suffix></name> <name><surname>Tyberg</surname> <given-names>JV</given-names></name> <etal/></person-group>. <article-title>Oxygenation-sensitive CMR for assessing vasodilator-induced changes of myocardial oxygenation</article-title>. <source>J Cardiovasc Magn Reson.</source> (<year>2010</year>) <volume>12</volume>:<fpage>20</fpage>. <pub-id pub-id-type="doi">10.1186/1532-429X-12-20</pub-id><pub-id pub-id-type="pmid">20356402</pub-id></citation></ref>
<ref id="B11">
<label>11.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Utz</surname> <given-names>W</given-names></name> <name><surname>Jordan</surname> <given-names>J</given-names></name> <name><surname>Niendorf</surname> <given-names>T</given-names></name> <name><surname>Stoffels</surname> <given-names>M</given-names></name> <name><surname>Luft</surname> <given-names>FC</given-names></name> <name><surname>Dietz</surname> <given-names>R</given-names></name> <etal/></person-group>. <article-title>Blood oxygen level-dependent MRI of tissue oxygenation: relation to endothelium-dependent and endothelium-independent blood flow changes</article-title>. <source>Arterioscler Thromb Vasc Biol.</source> (<year>2005</year>) <volume>25</volume>:<fpage>1408</fpage>&#x02013;<lpage>13</lpage>. <pub-id pub-id-type="doi">10.1161/01.ATV.0000170131.13683.d7</pub-id><pub-id pub-id-type="pmid">15890970</pub-id></citation></ref>
<ref id="B12">
<label>12.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Guensch</surname> <given-names>DP</given-names></name> <name><surname>Fischer</surname> <given-names>K</given-names></name> <name><surname>Flewitt</surname> <given-names>JA</given-names></name> <name><surname>Friedrich</surname> <given-names>MG</given-names></name></person-group>. <article-title>Impact of intermittent apnea on myocardial tissue oxygenation&#x02013;a study using oxygenation-sensitive cardiovascular magnetic resonance</article-title>. <source>PLoS ONE</source> (<year>2013</year>) <volume>8</volume>:<fpage>e53282</fpage>. <pub-id pub-id-type="doi">10.1371/journal.pone.0053282</pub-id></citation></ref>
<ref id="B13">
<label>13.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Guensch</surname> <given-names>DP</given-names></name> <name><surname>Fischer</surname> <given-names>K</given-names></name> <name><surname>Flewitt</surname> <given-names>JA</given-names></name> <name><surname>Friedrich</surname> <given-names>MG</given-names></name></person-group>. <article-title>Myocardial oxygenation is maintained during hypoxia when combined with apnea&#x02013;a cardiovascular MR study</article-title>. <source>Physiol. Rep.</source> (<year>2013</year>) <volume>1</volume>:<fpage>e00098</fpage>. <pub-id pub-id-type="doi">10.1002/phy2.98</pub-id><pub-id pub-id-type="pmid">24303170</pub-id></citation></ref>
<ref id="B14">
<label>14.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Guensch</surname> <given-names>DP</given-names></name> <name><surname>Fischer</surname> <given-names>K</given-names></name> <name><surname>Flewitt</surname> <given-names>JA</given-names></name> <name><surname>Yu</surname> <given-names>J</given-names></name> <name><surname>Lukic</surname> <given-names>R</given-names></name> <name><surname>Friedrich</surname> <given-names>JA</given-names></name> <etal/></person-group>. <article-title>Breathing manoeuvre-dependent changes in myocardial oxygenation in healthy humans</article-title>. <source>Eur Heart J Cardiovasc Imaging</source> (<year>2014</year>) <volume>15</volume>:<fpage>409</fpage>&#x02013;<lpage>14</lpage>. <pub-id pub-id-type="doi">10.1093/ehjci/jet171</pub-id><pub-id pub-id-type="pmid">24078154</pub-id></citation></ref>
<ref id="B15">
<label>15.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fischer</surname> <given-names>K</given-names></name> <name><surname>Guensch</surname> <given-names>DP</given-names></name> <name><surname>Shie</surname> <given-names>N</given-names></name> <name><surname>Lebel</surname> <given-names>J</given-names></name> <name><surname>Friedrich</surname> <given-names>MG</given-names></name></person-group>. <article-title>Breathing maneuvers as a vasoactive stimulus for detecting inducible myocardial ischemia - an experimental cardiovascular magnetic resonance study</article-title>. <source>PLoS ONE</source> (<year>2016</year>) <volume>11</volume>:<fpage>e0164524</fpage>. <pub-id pub-id-type="doi">10.1371/journal.pone.0164524</pub-id><pub-id pub-id-type="pmid">27741282</pub-id></citation></ref>
<ref id="B16">
<label>16.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Aguor</surname> <given-names>EN</given-names></name> <name><surname>Arslan</surname> <given-names>F</given-names></name> <name><surname>van de Kolk</surname> <given-names>CW</given-names></name> <name><surname>Nederhoff</surname> <given-names>MG</given-names></name> <name><surname>Doevendans</surname> <given-names>PA</given-names></name> <name><surname>van Echteld</surname> <given-names>CJ</given-names></name> <etal/></person-group>. <article-title>Quantitative T2<sup>&#x0002A;</sup> assessment of acute and chronic myocardial ischemia/reperfusion injury in mice</article-title>. <source>Magn Reson Mater Phys Biol Med.</source> (<year>2012</year>) <volume>25</volume>:<fpage>369</fpage>&#x02013;<lpage>79</lpage>. <pub-id pub-id-type="doi">10.1007/s10334-012-0304-0</pub-id></citation></ref>
<ref id="B17">
<label>17.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>de Jong</surname> <given-names>S</given-names></name> <name><surname>Zwanenburg</surname> <given-names>JJ</given-names></name> <name><surname>Visser</surname> <given-names>F</given-names></name> <name><surname>van der Nagel</surname> <given-names>R</given-names></name> <name><surname>van Rijen</surname> <given-names>HV</given-names></name> <name><surname>Vos</surname> <given-names>MA</given-names></name> <etal/></person-group>. <article-title>Direct detection of myocardial fibrosis by MRI</article-title>. <source>J Mol Cell Cardiol.</source> (<year>2011</year>) <volume>51</volume>:<fpage>974</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1016/j.yjmcc.2011.08.024</pub-id><pub-id pub-id-type="pmid">21910997</pub-id></citation></ref>
<ref id="B18">
<label>18.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>van Nierop</surname> <given-names>BJ</given-names></name> <name><surname>Bax</surname> <given-names>NA</given-names></name> <name><surname>Nelissen</surname> <given-names>JL</given-names></name> <name><surname>Arslan</surname> <given-names>F</given-names></name> <name><surname>Motaal</surname> <given-names>AG</given-names></name> <name><surname>de Graaf</surname> <given-names>L</given-names></name> <etal/></person-group>. <article-title>Assessment of myocardial fibrosis in mice using a T2<sup>&#x0002A;</sup>-weighted 3D radial magnetic resonance imaging sequence</article-title>. <source>PLoS ONE</source> (<year>2015</year>) <volume>10</volume>:<fpage>e0129899</fpage>. <pub-id pub-id-type="doi">10.1371/journal.pone.0129899</pub-id></citation></ref>
<ref id="B19">
<label>19.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>He</surname> <given-names>T</given-names></name></person-group>. <article-title>Cardiovascular magnetic resonance T2<sup>&#x0002A;</sup> for tissue iron assessment in the heart</article-title>. <source>Quant Imaging Med Surg.</source> (<year>2014</year>) <volume>4</volume>:<fpage>407</fpage>&#x02013;<lpage>12</lpage>. <pub-id pub-id-type="doi">10.3978/j.issn.2223-4292.2014.10.05</pub-id><pub-id pub-id-type="pmid">25392825</pub-id></citation></ref>
<ref id="B20">
<label>20.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Anderson</surname> <given-names>L</given-names></name> <name><surname>Holden</surname> <given-names>S</given-names></name> <name><surname>Davis</surname> <given-names>B</given-names></name> <name><surname>Prescott</surname> <given-names>E</given-names></name> <name><surname>Charrier</surname> <given-names>C</given-names></name> <name><surname>Bunce</surname> <given-names>N</given-names></name> <etal/></person-group>. <article-title>Cardiovascular T 2-star(T 2<sup>&#x0002A;</sup>) magnetic resonance for the early diagnosis of myocardial iron overload</article-title>. <source>Eur Heart J.</source> (<year>2001</year>) <volume>22</volume>:<fpage>2171</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1053/euhj.2001.2822</pub-id><pub-id pub-id-type="pmid">11913479</pub-id></citation></ref>
<ref id="B21">
<label>21.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mavrogeni</surname> <given-names>S</given-names></name></person-group>. <article-title>Evaluation of myocardial iron overload using magnetic resonance imaging</article-title>. <source>Blood Transfusion</source> (<year>2009</year>) <volume>7</volume>:<fpage>183</fpage>&#x02013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.2450/2008.0063-08</pub-id><pub-id pub-id-type="pmid">19657481</pub-id></citation></ref>
<ref id="B22">
<label>22.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Carpenter</surname> <given-names>J-P</given-names></name> <name><surname>He</surname> <given-names>T</given-names></name> <name><surname>Kirk</surname> <given-names>P</given-names></name> <name><surname>Roughton</surname> <given-names>M</given-names></name> <name><surname>Anderson</surname> <given-names>LJ</given-names></name> <name><surname>de Noronha</surname> <given-names>SV</given-names></name> <etal/></person-group>. <article-title>On T2<sup>&#x0002A;</sup> magnetic resonance and cardiac iron</article-title>. <source>Circulation</source> (<year>2011</year>) <volume>123</volume>:<fpage>1519</fpage>&#x02013;<lpage>28</lpage>. <pub-id pub-id-type="doi">10.1161/CIRCULATIONAHA.110.007641</pub-id><pub-id pub-id-type="pmid">21444881</pub-id></citation></ref>
<ref id="B23">
<label>23.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Friedrich</surname> <given-names>MG</given-names></name> <name><surname>Karamitsos</surname> <given-names>TD</given-names></name></person-group>. <article-title>Oxygenation-sensitive cardiovascular magnetic resonance</article-title>. <source>J Cardiovasc Magn Reson.</source> (<year>2013</year>) <volume>15</volume>:<fpage>43</fpage>. <pub-id pub-id-type="doi">10.1186/1532-429X-15-43</pub-id><pub-id pub-id-type="pmid">23706167</pub-id></citation></ref>
<ref id="B24">
<label>24.</label>
<citation citation-type="book"><person-group person-group-type="editor"><name><surname>Haacke</surname> <given-names>EM</given-names></name> <name><surname>Brown</surname> <given-names>RW</given-names></name> <name><surname>Thompson</surname> <given-names>MR</given-names></name> <name><surname>Venkatesan</surname> <given-names>R</given-names></name></person-group> editors. <article-title>Magnetization, relaxation and the bloch equation</article-title>. In: <source>Magnetic Resonance Imaging - Physical Principles and Sequence Design</source>. <edition>1st ed</edition>. <publisher-loc>New York, NY</publisher-loc>: <publisher-name>John Wiley &#x00026; Sons</publisher-name> (<year>1999</year>). <fpage>p. 51</fpage>&#x02013;<lpage>64</lpage>.</citation></ref>
<ref id="B25">
<label>25.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhao</surname> <given-names>JM</given-names></name> <name><surname>Clingman</surname> <given-names>CS</given-names></name> <name><surname>N&#x000E4;rv&#x000E4;inen</surname> <given-names>MJ</given-names></name> <name><surname>Kauppinen</surname> <given-names>RA</given-names></name> <name><surname>van Zijl</surname> <given-names>P</given-names></name></person-group>. <article-title>Oxygenation and hematocrit dependence of transverse relaxation rates of blood at 3T</article-title>. <source>Magn. Reson. Med.</source> (<year>2007</year>) <volume>58</volume>:<fpage>592</fpage>&#x02013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.21342</pub-id><pub-id pub-id-type="pmid">17763354</pub-id></citation></ref>
<ref id="B26">
<label>26.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ogawa</surname> <given-names>S</given-names></name> <name><surname>Lee</surname> <given-names>TM</given-names></name> <name><surname>Kay</surname> <given-names>AR</given-names></name> <name><surname>Tank</surname> <given-names>DW</given-names></name></person-group>. <article-title>Brain magnetic resonance imaging with contrast dependent on blood oxygenation</article-title>. <source>Proc Natl Acad Sci USA.</source> (<year>1990</year>) <volume>87</volume>:<fpage>9868</fpage>&#x02013;<lpage>72</lpage>. <pub-id pub-id-type="doi">10.1073/pnas.87.24.9868</pub-id><pub-id pub-id-type="pmid">2124706</pub-id></citation></ref>
<ref id="B27">
<label>27.</label>
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Brown</surname> <given-names>RW</given-names></name> <name><surname>Cheng</surname> <given-names>Y-CN</given-names></name> <name><surname>Haacke</surname> <given-names>EM</given-names></name> <name><surname>Thompson</surname> <given-names>MR</given-names></name> <name><surname>Venkatesan</surname> <given-names>R</given-names></name></person-group>. <source>Magnetic Resonance Imaging: Physical Principles and Sequence Design</source>. <publisher-loc>New York, NY</publisher-loc>: <publisher-name>John Wiley &#x00026; Sons</publisher-name> (<year>2014</year>).</citation></ref>
<ref id="B28">
<label>28.</label>
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Bernstein</surname> <given-names>MA</given-names></name> <name><surname>King</surname> <given-names>KF</given-names></name> <name><surname>Zhou</surname> <given-names>XJ</given-names></name></person-group>. <source>Handbook of MRI Pulse Sequences</source>. <publisher-loc>New York, NY</publisher-loc>: <publisher-name>Elsevier</publisher-name> (<year>2004</year>).</citation></ref>
<ref id="B29">
<label>29.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ogawa</surname> <given-names>S</given-names></name> <name><surname>Tank</surname> <given-names>DW</given-names></name> <name><surname>Menon</surname> <given-names>R</given-names></name> <name><surname>Ellermann</surname> <given-names>JM</given-names></name> <name><surname>Kim</surname> <given-names>SG</given-names></name> <name><surname>Merkle</surname> <given-names>H</given-names></name> <etal/></person-group>. <article-title>Intrinsic signal changes accompanying sensory stimulation: functional brain mapping with magnetic resonance imaging</article-title>. <source>Proc Natl Acad Sci USA.</source> (<year>1992</year>) <volume>89</volume>:<fpage>5951</fpage>&#x02013;<lpage>5</lpage>. <pub-id pub-id-type="doi">10.1073/pnas.89.13.5951</pub-id><pub-id pub-id-type="pmid">1631079</pub-id></citation></ref>
<ref id="B30">
<label>30.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bauer</surname> <given-names>WR</given-names></name> <name><surname>Nadler</surname> <given-names>W</given-names></name> <name><surname>Bock</surname> <given-names>M</given-names></name> <name><surname>Schad</surname> <given-names>LR</given-names></name> <name><surname>Wacker</surname> <given-names>C</given-names></name> <name><surname>Hartlep</surname> <given-names>A</given-names></name> <etal/></person-group>. <article-title>Theory of the BOLD effect in the capillary region: an analytical approach for the determination of T2 in the capillary network of myocardium</article-title>. <source>Magn Reson Med.</source> (<year>1999</year>) <volume>41</volume>:<fpage>51</fpage>&#x02013;<lpage>62</lpage>. <pub-id pub-id-type="pmid">10025611</pub-id></citation></ref>
<ref id="B31">
<label>31.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Guensch</surname> <given-names>DP</given-names></name> <name><surname>Nadeshalingam</surname> <given-names>G</given-names></name> <name><surname>Fischer</surname> <given-names>K</given-names></name> <name><surname>Stalder</surname> <given-names>AF</given-names></name> <name><surname>Friedrich</surname> <given-names>MG</given-names></name></person-group>. <article-title>The impact of hematocrit on oxygenation-sensitive cardiovascular magnetic resonance</article-title>. <source>J Cardiovasc Magn Reson.</source> (<year>2016</year>) <volume>18</volume>:<fpage>42</fpage>. <pub-id pub-id-type="doi">10.1186/s12968-016-0262-1</pub-id><pub-id pub-id-type="pmid">27435406</pub-id></citation></ref>
<ref id="B32">
<label>32.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yablonskiy</surname> <given-names>DA</given-names></name> <name><surname>Haacke</surname> <given-names>EM</given-names></name></person-group>. <article-title>Theory of NMR signal behavior in magnetically inhomogeneous tissues: the static dephasing regime</article-title>. <source>Magn Reson Med.</source> (<year>1994</year>) <volume>32</volume>:<fpage>749</fpage>&#x02013;<lpage>63</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.1910320610</pub-id><pub-id pub-id-type="pmid">7869897</pub-id></citation></ref>
<ref id="B33">
<label>33.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Christen</surname> <given-names>T</given-names></name> <name><surname>Lemasson</surname> <given-names>B</given-names></name> <name><surname>Pannetier</surname> <given-names>N</given-names></name> <name><surname>Farion</surname> <given-names>R</given-names></name> <name><surname>Segebarth</surname> <given-names>C</given-names></name> <name><surname>R&#x000E9;my</surname> <given-names>C</given-names></name> <etal/></person-group>. <article-title>Evaluation of a quantitative blood oxygenation level-dependent (qBOLD) approach to map local blood oxygen saturation</article-title>. <source>NMR Biomed.</source> (<year>2011</year>) <volume>24</volume>:<fpage>393</fpage>&#x02013;<lpage>403</lpage>. <pub-id pub-id-type="doi">10.1002/nbm.1603</pub-id><pub-id pub-id-type="pmid">20960585</pub-id></citation></ref>
<ref id="B34">
<label>34.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Spees</surname> <given-names>WM</given-names></name> <name><surname>Yablonskiy</surname> <given-names>DA</given-names></name> <name><surname>Oswood</surname> <given-names>MC</given-names></name> <name><surname>Ackerman</surname> <given-names>JJ</given-names></name></person-group>. <article-title>Water proton MR properties of human blood at 1</article-title>.5 tesla: magnetic susceptibility, T1, T2, T2<sup>&#x0002A;</sup>, and non-lorentzian signal behavior. <source>Magn Reson Med.</source> (<year>2001</year>) <volume>45</volume>:<fpage>533</fpage>&#x02013;<lpage>42</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.1072</pub-id><pub-id pub-id-type="pmid">11283978</pub-id></citation></ref>
<ref id="B35">
<label>35.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Niendorf</surname> <given-names>T</given-names></name> <name><surname>Pohlmann</surname> <given-names>A</given-names></name> <name><surname>Arakelyan</surname> <given-names>K</given-names></name> <name><surname>Flemming</surname> <given-names>B</given-names></name> <name><surname>Cantow</surname> <given-names>K</given-names></name> <name><surname>Hentschel</surname> <given-names>J</given-names></name> <etal/></person-group>. <article-title>How bold is blood oxygenation level-dependent (BOLD) magnetic resonance imaging of the kidney? Opportunities, challenges and future directions</article-title>. <source>Acta Physiol.</source> (<year>2015</year>) <volume>213</volume>:<fpage>19</fpage>&#x02013;<lpage>38</lpage>. <pub-id pub-id-type="doi">10.1111/apha.12393</pub-id><pub-id pub-id-type="pmid">25204811</pub-id></citation></ref>
<ref id="B36">
<label>36.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Meloni</surname> <given-names>A</given-names></name> <name><surname>Hezel</surname> <given-names>F</given-names></name> <name><surname>Positano</surname> <given-names>V</given-names></name> <name><surname>Keilberg</surname> <given-names>P</given-names></name> <name><surname>Pepe</surname> <given-names>A</given-names></name> <name><surname>Lombardi</surname> <given-names>M</given-names></name> <etal/></person-group>. <article-title>Detailing magnetic field strength dependence and segmental artifact distribution of myocardial effective transverse relaxation rate at 1.5, 3.0, and 7.0 T</article-title>. <source>Magn Reson Med.</source> (<year>2014</year>) <volume>71</volume>:<fpage>2224</fpage>&#x02013;<lpage>30</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.24856</pub-id><pub-id pub-id-type="pmid">23813553</pub-id></citation></ref>
<ref id="B37">
<label>37.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ocali</surname> <given-names>O</given-names></name> <name><surname>Atalar</surname> <given-names>E</given-names></name></person-group>. <article-title>Ultimate intrinsic signal-to-noise ratio in MRI</article-title>. <source>Magn Reson Med.</source> (<year>1998</year>) <volume>39</volume>:<fpage>462</fpage>&#x02013;<lpage>73</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.1910390317</pub-id><pub-id pub-id-type="pmid">9498603</pub-id></citation></ref>
<ref id="B38">
<label>38.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ugurbil</surname> <given-names>K</given-names></name> <name><surname>Adriany</surname> <given-names>G</given-names></name> <name><surname>Andersen</surname> <given-names>P</given-names></name> <name><surname>Chen</surname> <given-names>W</given-names></name> <name><surname>Garwood</surname> <given-names>M</given-names></name> <name><surname>Gruetter</surname> <given-names>R</given-names></name> <etal/></person-group>. <article-title>Ultrahigh field magnetic resonance imaging and spectroscopy</article-title>. <source>Magn Reson Imaging</source> (<year>2003</year>) <volume>21</volume>:<fpage>1263</fpage>&#x02013;<lpage>81</lpage>. <pub-id pub-id-type="doi">10.1016/j.mri.2003.08.027</pub-id><pub-id pub-id-type="pmid">14725934</pub-id></citation></ref>
<ref id="B39">
<label>39.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hezel</surname> <given-names>F</given-names></name> <name><surname>Thalhammer</surname> <given-names>C</given-names></name> <name><surname>Waiczies</surname> <given-names>S</given-names></name> <name><surname>Schulz-Menger</surname> <given-names>J</given-names></name> <name><surname>Niendorf</surname> <given-names>T</given-names></name></person-group>. <article-title>High spatial resolution and temporally resolved <inline-formula><mml:math id="M223"><mml:msubsup><mml:mrow><mml:mtext>T</mml:mtext></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow><mml:mrow><mml:mo>*</mml:mo></mml:mrow></mml:msubsup></mml:math></inline-formula> mapping of normal human myocardium at 7.0 tesla: an ultrahigh field magnetic resonance feasibility study</article-title>. <source>PLoS ONE</source> (<year>2012</year>) <volume>7</volume>:<fpage>e52324</fpage>. <pub-id pub-id-type="doi">10.1371/journal.pone.0052324</pub-id><pub-id pub-id-type="pmid">23251708</pub-id></citation></ref>
<ref id="B40">
<label>40.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mueller</surname> <given-names>A</given-names></name> <name><surname>Kouwenhoven</surname> <given-names>M</given-names></name> <name><surname>Naehle</surname> <given-names>CP</given-names></name> <name><surname>Gieseke</surname> <given-names>J</given-names></name> <name><surname>Strach</surname> <given-names>K</given-names></name> <name><surname>Willinek</surname> <given-names>WA</given-names></name> <etal/></person-group>. <article-title>Dual-source radiofrequency transmission with patient-adaptive local radiofrequency shimming for 3</article-title>.0-T cardiac mr imaging: initial experience. <source>Radiology</source> (<year>2012</year>) <volume>263</volume>:<fpage>77</fpage>&#x02013;<lpage>85</lpage>. <pub-id pub-id-type="doi">10.1148/radiol.11110347</pub-id><pub-id pub-id-type="pmid">22371610</pub-id></citation></ref>
<ref id="B41">
<label>41.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Vaughan</surname> <given-names>JT</given-names></name> <name><surname>Snyder</surname> <given-names>CJ</given-names></name> <name><surname>DelaBarre</surname> <given-names>LJ</given-names></name> <name><surname>Bolan</surname> <given-names>PJ</given-names></name> <name><surname>Tian</surname> <given-names>J</given-names></name> <name><surname>Bolinger</surname> <given-names>L</given-names></name> <etal/></person-group>. <article-title>Whole-body imaging at 7T: preliminary results</article-title>. <source>Magn Reson Med.</source> (<year>2009</year>) <volume>61</volume>:<fpage>244</fpage>&#x02013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.21751</pub-id><pub-id pub-id-type="pmid">19097214</pub-id></citation></ref>
<ref id="B42">
<label>42.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Snyder</surname> <given-names>CJ</given-names></name> <name><surname>DelaBarre</surname> <given-names>L</given-names></name> <name><surname>Metzger</surname> <given-names>GJ</given-names></name> <name><surname>van de Moortele</surname> <given-names>PF</given-names></name> <name><surname>Akgun</surname> <given-names>C</given-names></name> <name><surname>Ugurbil</surname> <given-names>K</given-names></name> <etal/></person-group>. <article-title>Initial results of cardiac imaging at 7 Tesla</article-title>. <source>Magn Reson Med.</source> (<year>2009</year>) <volume>61</volume>:<fpage>517</fpage>&#x02013;<lpage>24</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.21895</pub-id><pub-id pub-id-type="pmid">19097233</pub-id></citation></ref>
<ref id="B43">
<label>43.</label>
<citation citation-type="book"><person-group person-group-type="editor"><name><surname>Maderwald</surname> <given-names>S</given-names></name> <name><surname>Orzada</surname> <given-names>S</given-names></name> <name><surname>Schaefer</surname> <given-names>LC</given-names></name> <name><surname>Bitz</surname> <given-names>AK</given-names></name> <name><surname>Brote</surname> <given-names>I</given-names></name> <name><surname>Kraff</surname> <given-names>O</given-names></name> <etal/></person-group> editors. <article-title>7T Human <italic>in vivo</italic> cardiac imaging with an 8-channel transmit/receive array</article-title>. In: <source>Proceedings of the International Society for Magnetic Resonance Medicine.</source> <publisher-loc>Honolulu, HI</publisher-loc> (<year>2009</year>).</citation></ref>
<ref id="B44">
<label>44.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>van den Bergen</surname> <given-names>B</given-names></name> <name><surname>Klomp</surname> <given-names>DW</given-names></name> <name><surname>Raaijmakers</surname> <given-names>AJ</given-names></name> <name><surname>de Castro</surname> <given-names>CA</given-names></name> <name><surname>Boer</surname> <given-names>VO</given-names></name> <name><surname>Kroeze</surname> <given-names>H</given-names></name> <etal/></person-group>. <article-title>Uniform prostate imaging and spectroscopy at 7 T: comparison between a microstrip array and an endorectal coil</article-title>. <source>NMR Biomed.</source> (<year>2011</year>) <volume>24</volume>:<fpage>358</fpage>&#x02013;<lpage>65</lpage>. <pub-id pub-id-type="doi">10.1002/nbm.1599</pub-id><pub-id pub-id-type="pmid">20960577</pub-id></citation></ref>
<ref id="B45">
<label>45.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ipek</surname> <given-names>O</given-names></name> <name><surname>Raaijmakers</surname> <given-names>AJ</given-names></name> <name><surname>Klomp</surname> <given-names>DW</given-names></name> <name><surname>Lagendijk</surname> <given-names>JJ</given-names></name> <name><surname>Luijten</surname> <given-names>PR</given-names></name> <name><surname>van den Berg</surname> <given-names>CA</given-names></name></person-group>. <article-title>Characterization of transceive surface element designs for 7 tesla magnetic resonance imaging of the prostate: radiative antenna and microstrip</article-title>. <source>Phys Med Biol.</source> (<year>2012</year>) <volume>57</volume>:<fpage>343</fpage>&#x02013;<lpage>55</lpage>. <pub-id pub-id-type="doi">10.1088/0031-9155/57/2/343</pub-id><pub-id pub-id-type="pmid">22170777</pub-id></citation></ref>
<ref id="B46">
<label>46.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Winter</surname> <given-names>L</given-names></name> <name><surname>&#x000D6;zerdem</surname> <given-names>C</given-names></name> <name><surname>Hoffmann</surname> <given-names>W</given-names></name> <name><surname>Santoro</surname> <given-names>D</given-names></name> <name><surname>M&#x000FC;ller</surname> <given-names>A</given-names></name> <name><surname>Waiczies</surname> <given-names>H</given-names></name> <etal/></person-group>. <article-title>Design and evaluation of a hybrid radiofrequency applicator for magnetic resonance imaging and RF induced hyperthermia: electromagnetic field simulations up to 14.0 tesla and proof-of-concept at 7.0 tesla</article-title>. <source>PLoS ONE</source> (<year>2013</year>) <volume>8</volume>:<fpage>e61661</fpage>. <pub-id pub-id-type="doi">10.1371/journal.pone.0061661</pub-id><pub-id pub-id-type="pmid">23613896</pub-id></citation></ref>
<ref id="B47">
<label>47.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Oezerdem</surname> <given-names>C</given-names></name> <name><surname>Winter</surname> <given-names>L</given-names></name> <name><surname>Graessl</surname> <given-names>A</given-names></name> <name><surname>Paul</surname> <given-names>K</given-names></name> <name><surname>Els</surname> <given-names>A</given-names></name> <name><surname>Weinberger</surname> <given-names>O</given-names></name> <etal/></person-group>. <article-title>16-channel bow tie antenna transceiver array for cardiac MR at 7.0 tesla</article-title>. <source>Magn Reson Med.</source> (<year>2016</year>) <volume>75</volume>:<fpage>2553</fpage>&#x02013;<lpage>65</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.25840</pub-id><pub-id pub-id-type="pmid">26183320</pub-id></citation></ref>
<ref id="B48">
<label>48.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Raaijmakers</surname> <given-names>AJ</given-names></name> <name><surname>Ipek</surname> <given-names>O</given-names></name> <name><surname>Klomp</surname> <given-names>DW</given-names></name> <name><surname>Possanzini</surname> <given-names>C</given-names></name> <name><surname>Harvey</surname> <given-names>PR</given-names></name> <name><surname>Lagendijk</surname> <given-names>JJ</given-names></name> <etal/></person-group>. <article-title>Design of a radiative surface coil array element at 7 T: the single-side adapted dipole antenna</article-title>. <source>Magn Reson Med.</source> (<year>2011</year>) <volume>66</volume>:<fpage>1488</fpage>&#x02013;<lpage>97</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.22886</pub-id><pub-id pub-id-type="pmid">21630342</pub-id></citation></ref>
<ref id="B49">
<label>49.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ipek</surname> <given-names>O</given-names></name> <name><surname>Raaijmakers</surname> <given-names>AJ</given-names></name> <name><surname>Lagendijk</surname> <given-names>JJ</given-names></name> <name><surname>Luijten</surname> <given-names>PR</given-names></name> <name><surname>van den Berg</surname> <given-names>CA</given-names></name></person-group>. <article-title>Intersubject local SAR variation for 7T prostate MR imaging with an eight-channel single-side adapted dipole antenna array</article-title>. <source>Magn Reson Med.</source> (<year>2014</year>) <volume>71</volume>:<fpage>1559</fpage>&#x02013;<lpage>67</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.24794</pub-id><pub-id pub-id-type="pmid">23754584</pub-id></citation></ref>
<ref id="B50">
<label>50.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Erturk</surname> <given-names>MA</given-names></name> <name><surname>Raaijmakers</surname> <given-names>AJ</given-names></name> <name><surname>Adriany</surname> <given-names>G</given-names></name> <name><surname>Ugurbil</surname> <given-names>K</given-names></name> <name><surname>Metzger</surname> <given-names>GJ</given-names></name></person-group>. <article-title>A 16-channel combined loop-dipole transceiver array for 7 Tesla body MRI</article-title>. <source>Magn Reson Med.</source> (<year>2017</year>) <volume>77</volume>:<fpage>884</fpage>&#x02013;<lpage>94</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.26153</pub-id><pub-id pub-id-type="pmid">26887533</pub-id></citation></ref>
<ref id="B51">
<label>51.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Raaijmakers</surname> <given-names>AJE</given-names></name> <name><surname>Italiaander</surname> <given-names>M</given-names></name> <name><surname>Voogt</surname> <given-names>IJ</given-names></name> <name><surname>Luijten</surname> <given-names>PR</given-names></name> <name><surname>Hoogduin</surname> <given-names>JM</given-names></name> <name><surname>Klomp</surname> <given-names>DWJ</given-names></name> <etal/></person-group>. <article-title>The fractionated dipole antenna: a new antenna for body imaging at 7 Tesla</article-title>. <source>Magn Reson Med.</source> (<year>2016</year>) <volume>75</volume>:<fpage>1366</fpage>&#x02013;<lpage>74</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.25596</pub-id><pub-id pub-id-type="pmid">25939890</pub-id></citation></ref>
<ref id="B52">
<label>52.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Aussenhofer</surname> <given-names>SA</given-names></name> <name><surname>Webb</surname> <given-names>AG</given-names></name></person-group>. <article-title>An eight-channel transmit/receive array of TE<sub>01</sub> mode high permittivity ceramic resonators for human imaging at 7T</article-title>. <source>J Magn Reson.</source> (<year>2014</year>) <volume>243</volume>:<fpage>122</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1016/j.jmr.2014.04.001</pub-id><pub-id pub-id-type="pmid">24818565</pub-id></citation></ref>
<ref id="B53">
<label>53.</label>
<citation citation-type="book"><person-group person-group-type="editor"><name><surname>Alon</surname> <given-names>L</given-names></name> <name><surname>Deniz</surname> <given-names>CM</given-names></name> <name><surname>Brown</surname> <given-names>R</given-names></name> <name><surname>Sodickson</surname> <given-names>DK</given-names></name> <name><surname>Collins</surname> <given-names>CM</given-names></name></person-group> editors. <article-title>A slot antenna concept for high fidelity body imaging at ultra high field</article-title>. In: <source>Proceedings of the International Society for Magnetic Resonance Medicine.</source> <publisher-loc>Singapore</publisher-loc> (<year>2016</year>).</citation></ref>
<ref id="B54">
<label>54.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Versluis</surname> <given-names>MJ</given-names></name> <name><surname>Tsekos</surname> <given-names>N</given-names></name> <name><surname>Smith</surname> <given-names>NB</given-names></name> <name><surname>Webb</surname> <given-names>AG</given-names></name></person-group>. <article-title>Simple RF design for human functional and morphological cardiac imaging at 7tesla</article-title>. <source>J Magn Reson.</source> (<year>2009</year>) <volume>200</volume>:<fpage>161</fpage>&#x02013;<lpage>6</lpage>. <pub-id pub-id-type="doi">10.1016/j.jmr.2009.06.014</pub-id><pub-id pub-id-type="pmid">19595618</pub-id></citation></ref>
<ref id="B55">
<label>55.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dieringer</surname> <given-names>MA</given-names></name> <name><surname>Renz</surname> <given-names>W</given-names></name> <name><surname>Lindel</surname> <given-names>T</given-names></name> <name><surname>Seifert</surname> <given-names>F</given-names></name> <name><surname>Frauenrath</surname> <given-names>T</given-names></name> <name><surname>von Knobelsdorff-Brenkenhoff</surname> <given-names>F</given-names></name> <etal/></person-group>. <article-title>Design and application of a four-channel transmit/receive surface coil for functional cardiac imaging at 7T</article-title>. <source>J Magn Reson Imaging</source> (<year>2011</year>) <volume>33</volume>:<fpage>736</fpage>&#x02013;<lpage>41</lpage>. <pub-id pub-id-type="doi">10.1002/jmri.22451</pub-id><pub-id pub-id-type="pmid">21438067</pub-id></citation></ref>
<ref id="B56">
<label>56.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Thalhammer</surname> <given-names>C</given-names></name> <name><surname>Renz</surname> <given-names>W</given-names></name> <name><surname>Winter</surname> <given-names>L</given-names></name> <name><surname>Hezel</surname> <given-names>F</given-names></name> <name><surname>Rieger</surname> <given-names>J</given-names></name> <name><surname>Pfeiffer</surname> <given-names>H</given-names></name> <etal/></person-group>. <article-title>Two-Dimensional sixteen channel transmit/receive coil array for cardiac MRI at 7.0 T: design, evaluation, and application</article-title>. <source>J Magn Reson Imaging</source> (<year>2012</year>) <volume>36</volume>:<fpage>847</fpage>&#x02013;<lpage>57</lpage>. <pub-id pub-id-type="doi">10.1002/jmri.23724</pub-id><pub-id pub-id-type="pmid">22706727</pub-id></citation></ref>
<ref id="B57">
<label>57.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Winter</surname> <given-names>L</given-names></name> <name><surname>Kellman</surname> <given-names>P</given-names></name> <name><surname>Renz</surname> <given-names>W</given-names></name> <name><surname>Gr&#x000E4;&#x000DF;l</surname> <given-names>A</given-names></name> <name><surname>Hezel</surname> <given-names>F</given-names></name> <name><surname>Thalhammer</surname> <given-names>C</given-names></name> <etal/></person-group>. <article-title>Comparison of three multichannel transmit/receive radiofrequency coil configurations for anatomic and functional cardiac MRI at 7</article-title>.0T: implications for clinical imaging. <source>Eur Radiol.</source> (<year>2012</year>) <volume>22</volume>:<fpage>2211</fpage>&#x02013;<lpage>20</lpage>. <pub-id pub-id-type="doi">10.1007/s00330-012-2487-1</pub-id><pub-id pub-id-type="pmid">22653280</pub-id></citation></ref>
<ref id="B58">
<label>58.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Graessl</surname> <given-names>A</given-names></name> <name><surname>Winter</surname> <given-names>L</given-names></name> <name><surname>Thalhammer</surname> <given-names>C</given-names></name> <name><surname>Renz</surname> <given-names>W</given-names></name> <name><surname>Kellman</surname> <given-names>P</given-names></name> <name><surname>Martin</surname> <given-names>C</given-names></name> <etal/></person-group>. <article-title>Design, evaluation and application of an eight channel transmit/receive coil array for cardiac MRI at 7.0 T</article-title>. <source>Eur J. Radiol.</source> (<year>2013</year>) <volume>82</volume>:<fpage>752</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1016/j.ejrad.2011.08.002</pub-id><pub-id pub-id-type="pmid">21920683</pub-id></citation></ref>
<ref id="B59">
<label>59.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Graessl</surname> <given-names>A</given-names></name> <name><surname>Renz</surname> <given-names>W</given-names></name> <name><surname>Hezel</surname> <given-names>F</given-names></name> <name><surname>Dieringer</surname> <given-names>MA</given-names></name> <name><surname>Winter</surname> <given-names>L</given-names></name> <name><surname>Oezerdem</surname> <given-names>C</given-names></name> <etal/></person-group>. <article-title>Modular 32-channel transceiver coil array for cardiac MRI at 7</article-title>.0T. <source>Magn Reson Med.</source> (<year>2014</year>) <volume>72</volume>:<fpage>276</fpage>&#x02013;<lpage>90</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.24903</pub-id><pub-id pub-id-type="pmid">23904404</pub-id></citation></ref>
<ref id="B60">
<label>60.</label>
<citation citation-type="book"><person-group person-group-type="editor"><name><surname>Adriany</surname> <given-names>G</given-names></name> <name><surname>Ritter</surname> <given-names>J</given-names></name> <name><surname>Vaughan</surname> <given-names>JT</given-names></name> <name><surname>Ugurbil</surname> <given-names>K</given-names></name> <name><surname>Moortele</surname> <given-names>PF</given-names></name></person-group> editors. <article-title>Experimental verification of enhanced B1 shim performance with a Z-encoding RF coil array at 7 Tesla</article-title>. In: <source>Proceedings of the International Society for Magnetic Resonance Medicine.</source> <publisher-loc>Stockholm</publisher-loc> (<year>2010</year>).</citation></ref>
<ref id="B61">
<label>61.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Frauenrath</surname> <given-names>T</given-names></name> <name><surname>Hezel</surname> <given-names>F</given-names></name> <name><surname>Renz</surname> <given-names>W</given-names></name> <name><surname>de Geyer</surname> <given-names>TdO</given-names></name> <name><surname>Dieringer</surname> <given-names>M</given-names></name> <name><surname>Knobelsdorff-Brenkenhoff</surname> <given-names>FV</given-names></name> <etal/></person-group>. <article-title>Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla</article-title>. <source>J Cardiovasc Magn Reson.</source> (<year>2010</year>) <volume>12</volume>:<fpage>67</fpage>. <pub-id pub-id-type="doi">10.1186/1532-429X-12-67</pub-id><pub-id pub-id-type="pmid">21080933</pub-id></citation></ref>
<ref id="B62">
<label>62.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Togawa</surname> <given-names>T</given-names></name> <name><surname>Okai</surname> <given-names>O</given-names></name> <name><surname>Oshima</surname> <given-names>M</given-names></name></person-group>. <article-title>Observation of blood flow E</article-title>.M.F. in externally applied strong magnetic field by surface electrodes. <source>Med Biol Eng.</source> (<year>1967</year>) <volume>5</volume>:<fpage>169</fpage>&#x02013;<lpage>70</lpage>. <pub-id pub-id-type="doi">10.1007/BF02474505</pub-id><pub-id pub-id-type="pmid">6039461</pub-id></citation></ref>
<ref id="B63">
<label>63.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Stuber</surname> <given-names>M</given-names></name> <name><surname>Botnar</surname> <given-names>RM</given-names></name> <name><surname>Fischer</surname> <given-names>SE</given-names></name> <name><surname>Lamerichs</surname> <given-names>R</given-names></name> <name><surname>Smink</surname> <given-names>J</given-names></name> <name><surname>Harvey</surname> <given-names>P</given-names></name> <etal/></person-group>. <article-title>Preliminary report on <italic>in vivo</italic> coronary MRA at 3 Tesla in humans</article-title>. <source>Magn Reson Med.</source> (<year>2002</year>) <volume>48</volume>:<fpage>425</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.10240</pub-id><pub-id pub-id-type="pmid">12210906</pub-id></citation></ref>
<ref id="B64">
<label>64.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lanzer</surname> <given-names>P</given-names></name> <name><surname>Barta</surname> <given-names>C</given-names></name> <name><surname>Botvinick</surname> <given-names>EH</given-names></name> <name><surname>Wiesendanger</surname> <given-names>HU</given-names></name> <name><surname>Modin</surname> <given-names>G</given-names></name> <name><surname>Higgins</surname> <given-names>CB</given-names></name></person-group>. <article-title>ECG-synchronized cardiac MR imaging: method and evaluation</article-title>. <source>Radiology</source> (<year>1985</year>) <volume>155</volume>:<fpage>681</fpage>&#x02013;<lpage>6</lpage>. <pub-id pub-id-type="doi">10.1148/radiology.155.3.4001369</pub-id><pub-id pub-id-type="pmid">4001369</pub-id></citation></ref>
<ref id="B65">
<label>65.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fischer</surname> <given-names>SE</given-names></name> <name><surname>Wickline</surname> <given-names>SA</given-names></name> <name><surname>Lorenz</surname> <given-names>CH</given-names></name></person-group>. <article-title>Novel real-time R-wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitions</article-title>. <source>Magn Reson Med.</source> (<year>1999</year>) <volume>42</volume>:<fpage>361</fpage>&#x02013;<lpage>70</lpage>. <pub-id pub-id-type="pmid">10440961</pub-id></citation></ref>
<ref id="B66">
<label>66.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chia</surname> <given-names>JM</given-names></name> <name><surname>Fischer</surname> <given-names>SE</given-names></name> <name><surname>Wickline</surname> <given-names>SA</given-names></name> <name><surname>Lorenz</surname> <given-names>CH</given-names></name></person-group>. <article-title>Performance of QRS detection for cardiac magnetic resonance imaging with a novel vectorcardiographic triggering method</article-title>. <source>J Magn Reson Imaging</source> (<year>2000</year>) <volume>12</volume>:<fpage>678</fpage>&#x02013;<lpage>88</lpage>. <pub-id pub-id-type="doi">10.1002/1522-2586(200011)12:5&#x0003C;678::aid-jmri4&#x0003E;3.0.co;2-5</pub-id><pub-id pub-id-type="pmid">11050637</pub-id></citation></ref>
<ref id="B67">
<label>67.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Becker</surname> <given-names>M</given-names></name> <name><surname>Frauenrath</surname> <given-names>T</given-names></name> <name><surname>Hezel</surname> <given-names>F</given-names></name> <name><surname>Krombach</surname> <given-names>GA</given-names></name> <name><surname>Kremer</surname> <given-names>U</given-names></name> <name><surname>Koppers</surname> <given-names>B</given-names></name> <etal/></person-group>. <article-title>Comparison of left ventricular function assessment using phonocardiogram- and electrocardiogram-triggered 2D SSFP CINE MR imaging at 1</article-title>.5 T and 3.0 T. <source>Eur Radiol.</source> (<year>2010</year>) <volume>20</volume>:<fpage>1344</fpage>&#x02013;<lpage>55</lpage>. <pub-id pub-id-type="doi">10.1007/s00330-009-1676-z</pub-id><pub-id pub-id-type="pmid">20013275</pub-id></citation></ref>
<ref id="B68">
<label>68.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Frauenrath</surname> <given-names>T</given-names></name> <name><surname>Hezel</surname> <given-names>F</given-names></name> <name><surname>Heinrichs</surname> <given-names>U</given-names></name> <name><surname>Kozerke</surname> <given-names>S</given-names></name> <name><surname>Utting</surname> <given-names>JF</given-names></name> <name><surname>Kob</surname> <given-names>M</given-names></name> <etal/></person-group>. <article-title>Feasibility of cardiac gating free of interference with electro-magnetic fields at 1.5 Tesla, 3.0 Tesla and 7.0 Tesla using an MR-stethoscope</article-title>. <source>Invest Radiol.</source> (<year>2009</year>) <volume>44</volume>:<fpage>539</fpage>&#x02013;<lpage>47</lpage>. <pub-id pub-id-type="doi">10.1097/RLI.0b013e3181b4c15e</pub-id><pub-id pub-id-type="pmid">19652614</pub-id></citation></ref>
<ref id="B69">
<label>69.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Brandts</surname> <given-names>A</given-names></name> <name><surname>Westenberg</surname> <given-names>JJ</given-names></name> <name><surname>Versluis</surname> <given-names>MJ</given-names></name> <name><surname>Kroft</surname> <given-names>LJ</given-names></name> <name><surname>Smith</surname> <given-names>NB</given-names></name> <name><surname>Webb</surname> <given-names>AG</given-names></name> <etal/></person-group>. <article-title>Quantitative assessment of left ventricular function in humans at 7 T</article-title>. <source>Magn Reson Med.</source> (<year>2010</year>) <volume>64</volume>:<fpage>1471</fpage>&#x02013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.22529</pub-id><pub-id pub-id-type="pmid">20593368</pub-id></citation></ref>
<ref id="B70">
<label>70.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Frauenrath</surname> <given-names>T</given-names></name> <name><surname>Niendorf</surname> <given-names>T</given-names></name> <name><surname>Malte</surname> <given-names>K</given-names></name></person-group>. <article-title>Acoustic method for synchronization of magnetic resonance imaging (MRI)</article-title>. <source>Acta Acust. United Acust.</source> (<year>2008</year>) <volume>94</volume>:<fpage>148</fpage>&#x02013;<lpage>55</lpage>. <pub-id pub-id-type="doi">10.3813/AAA.918017</pub-id></citation></ref>
<ref id="B71">
<label>71.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Krug</surname> <given-names>JW</given-names></name> <name><surname>Rose</surname> <given-names>G</given-names></name> <name><surname>Clifford</surname> <given-names>GD</given-names></name> <name><surname>Oster</surname> <given-names>J</given-names></name></person-group>. <article-title>ECG-based gating in ultra high field cardiovascular magnetic resonance using an independent component analysis approach</article-title>. <source>J Cardiovasc Magn Reson.</source> (<year>2013</year>) <volume>15</volume>:<fpage>104</fpage>. <pub-id pub-id-type="doi">10.1186/1532-429X-15-104</pub-id><pub-id pub-id-type="pmid">24252594</pub-id></citation></ref>
<ref id="B72">
<label>72.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gregory</surname> <given-names>TS</given-names></name> <name><surname>Schmidt</surname> <given-names>EJ</given-names></name> <name><surname>Zhang</surname> <given-names>SH</given-names></name> <name><surname>Ho</surname> <given-names>Tse ZT</given-names></name></person-group>. <article-title>3DQRS: a method to obtain reliable QRS complex detection within high field MRI using 12-lead electrocardiogram traces</article-title>. <source>Magn Reson Med.</source> (<year>2014</year>) <volume>71</volume>:<fpage>1374</fpage>&#x02013;<lpage>80</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.25078</pub-id><pub-id pub-id-type="pmid">24453116</pub-id></citation></ref>
<ref id="B73">
<label>73.</label>
<citation citation-type="book"><person-group person-group-type="editor"><name><surname>Kosch</surname> <given-names>O</given-names></name> <name><surname>Thiel</surname> <given-names>F</given-names></name> <name><surname>Di Clemente</surname> <given-names>FS</given-names></name> <name><surname>Hein</surname> <given-names>M</given-names></name> <name><surname>Seifert</surname> <given-names>F</given-names></name></person-group> editors. <article-title>Monitoring of human cardio-pulmonary activity by multi-channel UWB-radar</article-title>. <source>Antennas and Propagation in Wireless Communications (APWC), 2011 IEEE-APS Topical Conference on.</source> <publisher-loc>Torino</publisher-loc>: <publisher-name>IEEE</publisher-name> (<year>2011</year>).</citation></ref>
<ref id="B74">
<label>74.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gross</surname> <given-names>S</given-names></name> <name><surname>Vionnet</surname> <given-names>L</given-names></name> <name><surname>Kasper</surname> <given-names>L</given-names></name> <name><surname>Dietrich</surname> <given-names>BE</given-names></name> <name><surname>Pruessmann</surname> <given-names>KP</given-names></name></person-group>. <article-title>Physiology recording with magnetic field probes for fMRI denoising</article-title>. <source>Neuroimage</source> (<year>in press</year>). [Epub ahead of print]. <pub-id pub-id-type="doi">10.1016/j.neuroimage.2017.01.022</pub-id><pub-id pub-id-type="pmid">28088483</pub-id></citation></ref>
<ref id="B75">
<label>75.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Maclaren</surname> <given-names>J</given-names></name> <name><surname>Aksoy</surname> <given-names>M</given-names></name> <name><surname>Bammer</surname> <given-names>R</given-names></name></person-group>. <article-title>Contact-free physiological monitoring using a markerless optical system</article-title>. <source>Magn Reson Med.</source> (<year>2015</year>) <volume>74</volume>:<fpage>571</fpage>&#x02013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.25781</pub-id><pub-id pub-id-type="pmid">25982242</pub-id></citation></ref>
<ref id="B76">
<label>76.</label>
<citation citation-type="book"><person-group person-group-type="editor"><name><surname>Fuchs</surname> <given-names>K</given-names></name> <name><surname>Hezel</surname> <given-names>F</given-names></name> <name><surname>Winter</surname> <given-names>L</given-names></name> <name><surname>Oezerdem</surname> <given-names>C</given-names></name> <name><surname>Graessl</surname> <given-names>A</given-names></name> <name><surname>Dieringer</surname> <given-names>M</given-names></name> <etal/></person-group>. editors. <article-title>Feasibility of cardiac fast spin echo imaging at 7.0 T using a two-dimensional 16 channel array of bowtie transceivers</article-title>. In: <source>Proceedings of the International Society for Magnetic Resonance Medicine.</source> <publisher-loc>Salt Lake City</publisher-loc> (<year>2013</year>).</citation></ref>
<ref id="B77">
<label>77.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Norris</surname> <given-names>DG</given-names></name> <name><surname>Boernert</surname> <given-names>P</given-names></name> <name><surname>Reese</surname> <given-names>T</given-names></name> <name><surname>Leibfritz</surname> <given-names>D</given-names></name></person-group>. <article-title>On the application of ultra-fast rare experiments</article-title>. <source>Magn Reson Med.</source> (<year>1992</year>) <volume>27</volume>:<fpage>142</fpage>&#x02013;<lpage>64</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.1910270114</pub-id><pub-id pub-id-type="pmid">1435200</pub-id></citation></ref>
<ref id="B78">
<label>78.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Carr</surname> <given-names>HY</given-names></name> <name><surname>Purcell</surname> <given-names>EM</given-names></name></person-group>. <article-title>Effects of diffusion on free precession in nuclear magnetic resonance experiments</article-title>. <source>Phys Rev.</source> (<year>1954</year>) <volume>94</volume>:<fpage>630</fpage>&#x02013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1103/PhysRev.94.630</pub-id></citation></ref>
<ref id="B79">
<label>79.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Meiboom</surname> <given-names>S</given-names></name> <name><surname>Gill</surname> <given-names>D</given-names></name></person-group>. <article-title>Modified spin-echo method for measuring nuclear relaxation times</article-title>. <source>Rev Sci Instrum.</source> (<year>1958</year>) <volume>29</volume>:<fpage>688</fpage>&#x02013;<lpage>91</lpage>. <pub-id pub-id-type="doi">10.1063/1.1716296</pub-id></citation></ref>
<ref id="B80">
<label>80.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Heinrichs</surname> <given-names>U</given-names></name> <name><surname>Utting</surname> <given-names>JF</given-names></name> <name><surname>Frauenrath</surname> <given-names>T</given-names></name> <name><surname>Hezel</surname> <given-names>F</given-names></name> <name><surname>Krombach</surname> <given-names>GA</given-names></name> <name><surname>Hodenius</surname> <given-names>MA</given-names></name> <etal/></person-group>. <article-title>Myocardial T2<sup>&#x0002A;</sup> mapping free of distortion using susceptibility-weighted fast spin-echo imaging: a feasibility study at 1</article-title>.5 T and 3.0 T. <source>Magn Reson Med.</source> (<year>2009</year>) <volume>62</volume>:<fpage>822</fpage>&#x02013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.22054</pub-id><pub-id pub-id-type="pmid">19526490</pub-id></citation></ref>
<ref id="B81">
<label>81.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Schick</surname> <given-names>F</given-names></name></person-group>. <article-title>SPLICE: sub-second diffusion-sensitive MR imaging using a modified fast spin-echo acquisition mode</article-title>. <source>Magn Reson Med.</source> (<year>1997</year>) <volume>38</volume>:<fpage>638</fpage>&#x02013;<lpage>44</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.1910380418</pub-id><pub-id pub-id-type="pmid">9324331</pub-id></citation></ref>
<ref id="B82">
<label>82.</label>
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Haacke</surname> <given-names>E</given-names></name> <name><surname>Brown</surname> <given-names>R</given-names></name> <name><surname>Thompson</surname> <given-names>M</given-names></name> <name><surname>Venkatesan</surname> <given-names>R</given-names></name> <name><surname>Bernstein</surname> <given-names>M</given-names></name> <name><surname>King</surname> <given-names>K</given-names></name> <etal/></person-group>. <source>Magnetic Resonance Imaging - Physical Principles and Sequence Design</source>. <publisher-loc>New York, NY</publisher-loc>: <publisher-name>John Wiley and Sons</publisher-name> (<year>1999</year>).</citation></ref>
<ref id="B83">
<label>83.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Robinson</surname> <given-names>S</given-names></name> <name><surname>Schodl</surname> <given-names>H</given-names></name> <name><surname>Trattnig</surname> <given-names>S</given-names></name></person-group>. <article-title>A method for unwrapping highly wrapped multi-echo phase images at very high field: UMPIRE</article-title>. <source>Magn Reson Med.</source> (<year>2013</year>) <volume>72</volume>:<fpage>80</fpage>&#x02013;<lpage>92</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.24897</pub-id><pub-id pub-id-type="pmid">23901001</pub-id></citation></ref>
<ref id="B84">
<label>84.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Huelnhagen</surname> <given-names>T</given-names></name> <name><surname>Hezel</surname> <given-names>F</given-names></name> <name><surname>Serradas Duarte</surname> <given-names>T</given-names></name> <name><surname>Pohlmann</surname> <given-names>A</given-names></name> <name><surname>Oezerdem</surname> <given-names>C</given-names></name> <name><surname>Flemming</surname> <given-names>B</given-names></name> <etal/></person-group>. <article-title>Myocardial effective transverse relaxation time T2<sup>&#x0002A;</sup> correlates with left ventricular wall thickness: a 7.0 T MRI study</article-title>. <source>Magn Reson Med.</source> (<year>2016</year>) <volume>77</volume>:<fpage>2381</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.26312</pub-id><pub-id pub-id-type="pmid">27342430</pub-id></citation></ref>
<ref id="B85">
<label>85.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jaffer</surname> <given-names>FA</given-names></name> <name><surname>Wen</surname> <given-names>H</given-names></name> <name><surname>Balaban</surname> <given-names>RS</given-names></name> <name><surname>Wolff</surname> <given-names>SD</given-names></name></person-group>. <article-title>A method to improve the BO homogeneity of the heart <italic>in vivo</italic></article-title>. <source>Magn Reson Med.</source> (<year>1996</year>) <volume>36</volume>:<fpage>375</fpage>&#x02013;<lpage>83</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.1910360308</pub-id><pub-id pub-id-type="pmid">8875407</pub-id></citation></ref>
<ref id="B86">
<label>86.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Schar</surname> <given-names>M</given-names></name> <name><surname>Kozerke</surname> <given-names>S</given-names></name> <name><surname>Fischer</surname> <given-names>SE</given-names></name> <name><surname>Boesiger</surname> <given-names>P</given-names></name></person-group>. <article-title>Cardiac SSFP imaging at 3 Tesla</article-title>. <source>Magn Reson Med.</source> (<year>2004</year>) <volume>51</volume>:<fpage>799</fpage>&#x02013;<lpage>806</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.20024</pub-id><pub-id pub-id-type="pmid">15065254</pub-id></citation></ref>
<ref id="B87">
<label>87.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Schar</surname> <given-names>M</given-names></name> <name><surname>Vonken</surname> <given-names>EJ</given-names></name> <name><surname>Stuber</surname> <given-names>M</given-names></name></person-group>. <article-title>Simultaneous B(0)- and B(1)&#x0002B;-map acquisition for fast localized shim, frequency, and RF power determination in the heart at 3 T</article-title>. <source>Magn Reson Med.</source> (<year>2010</year>) <volume>63</volume>:<fpage>419</fpage>&#x02013;<lpage>26</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.22234</pub-id><pub-id pub-id-type="pmid">20099330</pub-id></citation></ref>
<ref id="B88">
<label>88.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Reeder</surname> <given-names>SB</given-names></name> <name><surname>Faranesh</surname> <given-names>AZ</given-names></name> <name><surname>Boxermann</surname> <given-names>JL</given-names></name> <name><surname>McVeigh</surname> <given-names>ER</given-names></name></person-group>. <article-title><italic>In vivo</italic> measurement of <inline-formula><mml:math id="M224"><mml:msubsup><mml:mrow><mml:mtext>T</mml:mtext></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow><mml:mrow><mml:mo>*</mml:mo></mml:mrow></mml:msubsup></mml:math></inline-formula> and field inhomogeneity maps in the human heart at 1.5 T</article-title>. <source>Magn Reson Med.</source> (<year>1998</year>) <volume>39</volume>:<fpage>988</fpage>&#x02013;<lpage>98</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.1910390617</pub-id><pub-id pub-id-type="pmid">9621923</pub-id></citation></ref>
<ref id="B89">
<label>89.</label>
<citation citation-type="book"><person-group person-group-type="editor"><name><surname>Shah</surname> <given-names>S</given-names></name> <name><surname>Kellman</surname> <given-names>P</given-names></name> <name><surname>Greiser</surname> <given-names>A</given-names></name> <name><surname>Weale</surname> <given-names>PJ</given-names></name> <name><surname>Zuehlsdorff</surname> <given-names>S</given-names></name> <name><surname>Jerecic</surname> <given-names>R</given-names></name></person-group> editors. <article-title>Rapid fieldmap estimation for cardiac shimming</article-title>. In: <source>Proceedings of the International Society for Magnetic Resonance Medicine 17</source>. <publisher-loc>Honolulu, HI</publisher-loc> (<year>2009</year>).</citation></ref>
<ref id="B90">
<label>90.</label>
<citation citation-type="book"><person-group person-group-type="editor"><name><surname>Serradas Duarte</surname> <given-names>T</given-names></name> <name><surname>Huelnhagen</surname> <given-names>T</given-names></name> <name><surname>Niendorf</surname> <given-names>T</given-names></name></person-group> editors. <article-title>Assessment of myocardial B0 over the cardiac cycle at 7.0T: implications for susceptibility-based cardiac MR techniques</article-title>. In: <source>Proceedings of the International Society for Magnetic Resonance Medicine 24</source>. <publisher-loc>Singapore</publisher-loc> (<year>2016</year>).</citation></ref>
<ref id="B91">
<label>91.</label>
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Serradas Duarte</surname> <given-names>T</given-names></name></person-group>. <source>Detailing Myocardial B0 across the Cardiac Cycle at UHF: B0 Assessment and Implications for Susceptibility-based CMR Techniques</source>. <publisher-loc>Lisbon</publisher-loc>: <publisher-name>Universidade Nova de Lisboa</publisher-name> (<year>2016</year>).</citation></ref>
<ref id="B92">
<label>92.</label>
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Kelley</surname> <given-names>CT</given-names></name></person-group>. <source>Iterative Methods for Optimization</source>. <publisher-loc>Philadelphia</publisher-loc>: <publisher-name>Siam</publisher-name> (<year>1999</year>).</citation></ref>
<ref id="B93">
<label>93.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sandino</surname> <given-names>CM</given-names></name> <name><surname>Kellman</surname> <given-names>P</given-names></name> <name><surname>Arai</surname> <given-names>AE</given-names></name> <name><surname>Hansen</surname> <given-names>MS</given-names></name> <name><surname>Xue</surname> <given-names>H</given-names></name></person-group>. <article-title>Myocardial T2<sup>&#x0002A;</sup> mapping: influence of noise on accuracy and precision</article-title>. <source>J Cardiovasc Magn Reson.</source> (<year>2015</year>) <volume>17</volume>:<fpage>7</fpage>. <pub-id pub-id-type="doi">10.1186/s12968-015-0115-3</pub-id><pub-id pub-id-type="pmid">25648167</pub-id></citation></ref>
<ref id="B94">
<label>94.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Manjon</surname> <given-names>JV</given-names></name> <name><surname>Coupe</surname> <given-names>P</given-names></name> <name><surname>Marti-Bonmati</surname> <given-names>L</given-names></name> <name><surname>Collins</surname> <given-names>DL</given-names></name> <name><surname>Robles</surname> <given-names>M</given-names></name></person-group>. <article-title>Adaptive non-local means denoising of MR images with spatially varying noise levels</article-title>. <source>J Magn Reson Imaging</source> (<year>2010</year>) <volume>31</volume>:<fpage>192</fpage>&#x02013;<lpage>203</lpage>. <pub-id pub-id-type="doi">10.1002/jmri.22003</pub-id><pub-id pub-id-type="pmid">20027588</pub-id></citation></ref>
<ref id="B95">
<label>95.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Feng</surname> <given-names>Y</given-names></name> <name><surname>He</surname> <given-names>T</given-names></name> <name><surname>Feng</surname> <given-names>M</given-names></name> <name><surname>Carpenter</surname> <given-names>JP</given-names></name> <name><surname>Greiser</surname> <given-names>A</given-names></name> <name><surname>Xin</surname> <given-names>X</given-names></name> <etal/></person-group>. <article-title>Improved pixel-by-pixel MRI R2<sup>&#x0002A;</sup> relaxometry by nonlocal means</article-title>. <source>Magn Reson Med.</source> (<year>2014</year>) <volume>72</volume>:<fpage>260</fpage>&#x02013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.24914</pub-id><pub-id pub-id-type="pmid">23963595</pub-id></citation></ref>
<ref id="B96">
<label>96.</label>
<citation citation-type="book"><person-group person-group-type="editor"><name><surname>Huelnhagen</surname> <given-names>T</given-names></name> <name><surname>Pohlmann</surname> <given-names>A</given-names></name> <name><surname>Niendorf</surname> <given-names>T</given-names></name></person-group> editors. <article-title>Improving T2<sup>&#x0002A;</sup> mapping accuracy by spatially adaptive non-local means noise filtering</article-title>. In: <source>Proceedings of the International Society for Magnetic Resonance Medicine 23</source>. <publisher-loc>Toronto, ON</publisher-loc> (<year>2015</year>).</citation></ref>
<ref id="B97">
<label>97.</label>
<citation citation-type="book"><person-group person-group-type="editor"><name><surname>Guyton</surname> <given-names>AC</given-names></name> <name><surname>Hall</surname> <given-names>JE</given-names></name></person-group> editors. <article-title>Muscle blood flow and cardiac output during exercise; the coronary circulation and ischemic heart disease</article-title>. In: <source>Guyton and Hall Textbook of Medical Physiology</source>. <edition>10th ed</edition>. <publisher-loc>Philadelphia</publisher-loc>: <publisher-name>Saunders</publisher-name> (<year>2000</year>). <fpage>p. 223</fpage>&#x02013;<lpage>34</lpage>.</citation></ref>
<ref id="B98">
<label>98.</label>
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Schmidt</surname> <given-names>RF</given-names></name> <name><surname>Lang</surname> <given-names>F</given-names></name> <name><surname>Heckmann</surname> <given-names>M</given-names></name></person-group>. <article-title>Herzmechanik</article-title>. <source>Physiologie des Menschen: Mit Pathophysiologie</source>. <edition>31st ed</edition>. <publisher-loc>Heidelberg</publisher-loc>: <publisher-name>Springer</publisher-name> (<year>2010</year>). <fpage>p. 539</fpage>&#x02013;<lpage>64</lpage>.</citation></ref>
<ref id="B99">
<label>99.</label>
<citation citation-type="book"><person-group person-group-type="editor"><name><surname>Deussen</surname> <given-names>A</given-names></name></person-group>. <article-title>Herzstoffwechsel und Kroronardurchblutung</article-title>. In: Schmidt RF, Lang F, Heckmann M, editors. <source>Physiologie des Menschen: Mit Pathophysiologie</source>. <edition>31st ed</edition>. <publisher-loc>Heidelberg</publisher-loc>: <publisher-name>Springer</publisher-name> (<year>2010</year>). <fpage>p. 565</fpage>&#x02013;<lpage>71</lpage>.</citation></ref>
<ref id="B100">
<label>100.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Judd</surname> <given-names>RM</given-names></name> <name><surname>Levy</surname> <given-names>BI</given-names></name></person-group>. <article-title>Effects of barium-induced cardiac contraction on large-and small-vessel intramyocardial blood volume</article-title>. <source>Circ Res.</source> (<year>1991</year>) <volume>68</volume>:<fpage>217</fpage>&#x02013;<lpage>25</lpage>. <pub-id pub-id-type="doi">10.1161/01.RES.68.1.217</pub-id><pub-id pub-id-type="pmid">1984864</pub-id></citation></ref>
<ref id="B101">
<label>101.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fleckenstein</surname> <given-names>JL</given-names></name> <name><surname>Canby</surname> <given-names>RC</given-names></name> <name><surname>Parkey</surname> <given-names>RW</given-names></name> <name><surname>Peshock</surname> <given-names>RM</given-names></name></person-group>. <article-title>Acute effects of exercise on MR imaging of skeletal muscle in normal volunteers</article-title>. <source>AJR Am J Roentgenol.</source> (<year>1988</year>) <volume>151</volume>:<fpage>231</fpage>&#x02013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.2214/ajr.151.2.231</pub-id><pub-id pub-id-type="pmid">3260716</pub-id></citation></ref>
<ref id="B102">
<label>102.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Schmid</surname> <given-names>AI</given-names></name> <name><surname>Schewzow</surname> <given-names>K</given-names></name> <name><surname>Fiedler</surname> <given-names>GB</given-names></name> <name><surname>Goluch</surname> <given-names>S</given-names></name> <name><surname>Laistler</surname> <given-names>E</given-names></name> <name><surname>Wolzt</surname> <given-names>M</given-names></name> <etal/></person-group>. <article-title>Exercising calf muscle T2<sup>&#x0002A;</sup> changes correlate with pH, PCr recovery and maximum oxidative phosphorylation</article-title>. <source>NMR Biomed.</source> (<year>2014</year>) <volume>27</volume>:<fpage>553</fpage>&#x02013;<lpage>60</lpage>. <pub-id pub-id-type="doi">10.1002/nbm.3092</pub-id><pub-id pub-id-type="pmid">24610788</pub-id></citation></ref>
<ref id="B103">
<label>103.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mozaffarian</surname> <given-names>D</given-names></name> <name><surname>Benjamin</surname> <given-names>EJ</given-names></name> <name><surname>Go</surname> <given-names>AS</given-names></name> <name><surname>Arnett</surname> <given-names>DK</given-names></name> <name><surname>Blaha</surname> <given-names>MJ</given-names></name> <name><surname>Cushman</surname> <given-names>M</given-names></name> <etal/></person-group>. <article-title>Heart disease and stroke statistics&#x02014;2016 update a report from the american heart association</article-title>. <source>Circulation</source> (<year>2015</year>) <volume>133</volume>:<fpage>e38</fpage>&#x02013;<lpage>360</lpage>. <pub-id pub-id-type="doi">10.1161/CIR.0000000000000350</pub-id><pub-id pub-id-type="pmid">26673558</pub-id></citation></ref>
<ref id="B104">
<label>104.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kramer</surname> <given-names>CM</given-names></name> <name><surname>Appelbaum</surname> <given-names>E</given-names></name> <name><surname>Desai</surname> <given-names>MY</given-names></name> <name><surname>Desvigne-Nickens</surname> <given-names>P</given-names></name> <name><surname>DiMarco</surname> <given-names>JP</given-names></name> <name><surname>Friedrich</surname> <given-names>MG</given-names></name> <etal/></person-group>. <article-title>Hypertrophic Cardiomyopathy Registry: the rationale and design of an international, observational study of hypertrophic cardiomyopathy</article-title>. <source>Am Heart J.</source> (<year>2015</year>) <volume>170</volume>:<fpage>223</fpage>&#x02013;<lpage>30</lpage>. <pub-id pub-id-type="doi">10.1016/j.ahj.2015.05.013</pub-id><pub-id pub-id-type="pmid">26299218</pub-id></citation></ref>
<ref id="B105">
<label>105.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Maron</surname> <given-names>BJ</given-names></name> <name><surname>Olivotto</surname> <given-names>I</given-names></name> <name><surname>Spirito</surname> <given-names>P</given-names></name> <name><surname>Casey</surname> <given-names>SA</given-names></name> <name><surname>Bellone</surname> <given-names>P</given-names></name> <name><surname>Gohman</surname> <given-names>TE</given-names></name> <etal/></person-group>. <article-title>Epidemiology of hypertrophic cardiomyopathy&#x02013;related death revisited in a large non-referral-based patient population</article-title>. <source>Circulation</source> (<year>2000</year>) <volume>102</volume>:<fpage>858</fpage>&#x02013;<lpage>64</lpage>. <pub-id pub-id-type="doi">10.1161/01.CIR.102.8.858</pub-id><pub-id pub-id-type="pmid">10952953</pub-id></citation></ref>
<ref id="B106">
<label>106.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Noureldin</surname> <given-names>RA</given-names></name> <name><surname>Liu</surname> <given-names>S</given-names></name> <name><surname>Nacif</surname> <given-names>MS</given-names></name> <name><surname>Judge</surname> <given-names>DP</given-names></name> <name><surname>Halushka</surname> <given-names>MK</given-names></name> <name><surname>Abraham</surname> <given-names>TP</given-names></name> <etal/></person-group>. <article-title>The diagnosis of hypertrophic cardiomyopathy by cardiovascular magnetic resonance</article-title>. <source>J Cardiovasc Magn Reson.</source> (<year>2012</year>) <volume>14</volume>:<fpage>17</fpage>. <pub-id pub-id-type="doi">10.1186/1532-429X-14-17</pub-id><pub-id pub-id-type="pmid">22348519</pub-id></citation></ref>
<ref id="B107">
<label>107.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Steriotis</surname> <given-names>AK</given-names></name> <name><surname>Sharma</surname> <given-names>S</given-names></name></person-group>. <article-title>Risk stratification in hypertrophic cardiomyopathy</article-title>. <source>Eur Cardiol Rev.</source> (<year>2015</year>) <volume>10</volume>:<fpage>31</fpage>&#x02013;<lpage>6</lpage>. <pub-id pub-id-type="doi">10.15420/ecr.2015.10.01.31</pub-id></citation></ref>
<ref id="B108">
<label>108.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Abdel-Aty</surname> <given-names>H</given-names></name> <name><surname>Cocker</surname> <given-names>M</given-names></name> <name><surname>Strohm</surname> <given-names>O</given-names></name> <name><surname>Filipchuk</surname> <given-names>N</given-names></name> <name><surname>Friedrich</surname> <given-names>MG</given-names></name></person-group>. <article-title>Abnormalities in T2-weighted cardiovascular magnetic resonance images of hypertrophic cardiomyopathy: regional distribution and relation to late gadolinium enhancement and severity of hypertrophy</article-title>. <source>J Magn Reson Imaging</source> (<year>2008</year>) <volume>28</volume>:<fpage>242</fpage>&#x02013;<lpage>5</lpage>. <pub-id pub-id-type="doi">10.1002/jmri.21381</pub-id><pub-id pub-id-type="pmid">18581348</pub-id></citation></ref>
<ref id="B109">
<label>109.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Johansson</surname> <given-names>B</given-names></name> <name><surname>M&#x000F6;rner</surname> <given-names>S</given-names></name> <name><surname>Waldenstr&#x000F6;m</surname> <given-names>A</given-names></name> <name><surname>St&#x000E5;l</surname> <given-names>P</given-names></name></person-group>. <article-title>Myocardial capillary supply is limited in hypertrophic cardiomyopathy: a morphological analysis</article-title>. <source>Int J Cardiol.</source> (<year>2008</year>) <volume>126</volume>:<fpage>252</fpage>&#x02013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1016/j.ijcard.2007.04.003</pub-id><pub-id pub-id-type="pmid">17532066</pub-id></citation></ref>
<ref id="B110">
<label>110.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Cecchi</surname> <given-names>F</given-names></name> <name><surname>Olivotto</surname> <given-names>I</given-names></name> <name><surname>Gistri</surname> <given-names>R</given-names></name> <name><surname>Lorenzoni</surname> <given-names>R</given-names></name> <name><surname>Chiriatti</surname> <given-names>G</given-names></name> <name><surname>Camici</surname> <given-names>PG</given-names></name></person-group>. <article-title>Coronary microvascular dysfunction and prognosis in hypertrophic cardiomyopathy</article-title>. <source>New Engl J. Med.</source> (<year>2003</year>) <volume>349</volume>:<fpage>1027</fpage>&#x02013;<lpage>35</lpage>. <pub-id pub-id-type="doi">10.1056/NEJMoa025050</pub-id><pub-id pub-id-type="pmid">12968086</pub-id></citation></ref>
<ref id="B111">
<label>111.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Niendorf</surname> <given-names>T</given-names></name> <name><surname>Graessl</surname> <given-names>A</given-names></name> <name><surname>Thalhammer</surname> <given-names>C</given-names></name> <name><surname>Dieringer</surname> <given-names>MA</given-names></name> <name><surname>Kraus</surname> <given-names>O</given-names></name> <name><surname>Santoro</surname> <given-names>D</given-names></name> <etal/></person-group>. <article-title>Progress and promises of human cardiac magnetic resonance at ultrahigh fields: a physics perspective</article-title>. <source>J Magn Reson.</source> (<year>2013</year>) <volume>229</volume>:<fpage>208</fpage>&#x02013;<lpage>22</lpage>. <pub-id pub-id-type="doi">10.1016/j.jmr.2012.11.015</pub-id><pub-id pub-id-type="pmid">23290625</pub-id></citation></ref>
<ref id="B112">
<label>112.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Niendorf</surname> <given-names>T</given-names></name> <name><surname>Sodickson</surname> <given-names>DK</given-names></name> <name><surname>Krombach</surname> <given-names>GA</given-names></name> <name><surname>Schulz-Menger</surname> <given-names>J</given-names></name></person-group>. <article-title>Toward cardiovascular MRI at 7 T: clinical needs, technical solutions and research promises</article-title>. <source>Eur Radiol.</source> (<year>2010</year>) <volume>20</volume>:<fpage>2806</fpage>&#x02013;<lpage>16</lpage>. <pub-id pub-id-type="doi">10.1007/s00330-010-1902-8</pub-id><pub-id pub-id-type="pmid">20676653</pub-id></citation></ref>
<ref id="B113">
<label>113.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Niendorf</surname> <given-names>T</given-names></name> <name><surname>Paul</surname> <given-names>K</given-names></name> <name><surname>Oezerdem</surname> <given-names>C</given-names></name> <name><surname>Graessl</surname> <given-names>A</given-names></name> <name><surname>Klix</surname> <given-names>S</given-names></name> <name><surname>Huelnhagen</surname> <given-names>T</given-names></name> <etal/></person-group>. <article-title>W(h)ither human cardiac and body magnetic resonance at ultrahigh fields? Technical advances, practical considerations, applications, and clinical opportunities</article-title>. <source>NMR Biomed.</source> (<year>2016</year>) <volume>29</volume>:<fpage>1173</fpage>&#x02013;<lpage>97</lpage>. <pub-id pub-id-type="doi">10.1002/nbm.3268</pub-id><pub-id pub-id-type="pmid">25706103</pub-id></citation></ref>
<ref id="B114">
<label>114.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Schmitter</surname> <given-names>S</given-names></name> <name><surname>Wu</surname> <given-names>X</given-names></name> <name><surname>U&#x0011F;urbil</surname> <given-names>K</given-names></name> <name><surname>de Moortele</surname> <given-names>V</given-names></name></person-group>. <article-title>Design of parallel transmission radiofrequency pulses robust against respiration in cardiac MRI at 7 Tesla</article-title>. <source>Magn Reson Med.</source> (<year>2015</year>) <volume>74</volume>:<fpage>1291</fpage>&#x02013;<lpage>305</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.25512</pub-id><pub-id pub-id-type="pmid">25411131</pub-id></citation></ref>
<ref id="B115">
<label>115.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Schmitter</surname> <given-names>S</given-names></name> <name><surname>Moeller</surname> <given-names>S</given-names></name> <name><surname>Wu</surname> <given-names>X</given-names></name> <name><surname>Auerbach</surname> <given-names>EJ</given-names></name> <name><surname>Metzger</surname> <given-names>GJ</given-names></name> <name><surname>Van de Moortele</surname> <given-names>PF</given-names></name> <etal/></person-group>. <article-title>Simultaneous multislice imaging in dynamic cardiac MRI at 7T using parallel transmission</article-title>. <source>Magn Reson Med.</source> (<year>2016</year>) <volume>77</volume>:<fpage>1010</fpage>&#x02013;<lpage>20</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.26180</pub-id>. <pub-id pub-id-type="pmid">26949107</pub-id></citation></ref>
<ref id="B116">
<label>116.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Reichenbach</surname> <given-names>JR</given-names></name> <name><surname>Haacke</surname> <given-names>EM</given-names></name></person-group>. <article-title>High-resolution BOLD venographic imaging: a window into brain function</article-title>. <source>NMR Biomed.</source> (<year>2001</year>) <volume>14</volume>:<fpage>453</fpage>&#x02013;<lpage>67</lpage>. <pub-id pub-id-type="doi">10.1002/nbm.722</pub-id><pub-id pub-id-type="pmid">11746938</pub-id></citation></ref>
<ref id="B117">
<label>117.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Reese</surname> <given-names>TG</given-names></name> <name><surname>Weisskoff</surname> <given-names>RM</given-names></name> <name><surname>Smith</surname> <given-names>RN</given-names></name> <name><surname>Rosen</surname> <given-names>BR</given-names></name> <name><surname>Dinsmore</surname> <given-names>RE</given-names></name> <name><surname>Wedeen</surname> <given-names>VJ</given-names></name></person-group>. <article-title>Imaging myocardial fiber architecture <italic>in vivo</italic> with magnetic resonance</article-title>. <source>Magn Reson Med.</source> (<year>1995</year>) <volume>34</volume>:<fpage>786</fpage>&#x02013;<lpage>91</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.1910340603</pub-id><pub-id pub-id-type="pmid">8598805</pub-id></citation></ref>
<ref id="B118">
<label>118.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wu</surname> <given-names>MT</given-names></name> <name><surname>Tseng</surname> <given-names>WY</given-names></name> <name><surname>Su</surname> <given-names>MY</given-names></name> <name><surname>Liu</surname> <given-names>CP</given-names></name> <name><surname>Chiou</surname> <given-names>KR</given-names></name> <name><surname>Wedeen</surname> <given-names>VJ</given-names></name> <etal/></person-group>. <article-title>Diffusion tensor magnetic resonance imaging mapping the fiber architecture remodeling in human myocardium after infarction: correlation with viability and wall motion</article-title>. <source>Circulation</source> (<year>2006</year>) <volume>114</volume>:<fpage>1036</fpage>&#x02013;<lpage>45</lpage>. <pub-id pub-id-type="doi">10.1161/CIRCULATIONAHA.105.545863</pub-id><pub-id pub-id-type="pmid">16940196</pub-id></citation></ref>
<ref id="B119">
<label>119.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wagenhaus</surname> <given-names>B</given-names></name> <name><surname>Pohlmann</surname> <given-names>A</given-names></name> <name><surname>Dieringer</surname> <given-names>MA</given-names></name> <name><surname>Els</surname> <given-names>A</given-names></name> <name><surname>Waiczies</surname> <given-names>H</given-names></name> <name><surname>Waiczies</surname> <given-names>S</given-names></name> <etal/></person-group>. <article-title>Functional and morphological cardiac magnetic resonance imaging of mice using a cryogenic quadrature radiofrequency coil</article-title>. <source>PLoS ONE</source> (<year>2012</year>) <volume>7</volume>:<fpage>e42383</fpage>. <pub-id pub-id-type="doi">10.1371/journal.pone.0042383</pub-id><pub-id pub-id-type="pmid">22870323</pub-id></citation></ref>
<ref id="B120">
<label>120.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Niendorf</surname> <given-names>T</given-names></name> <name><surname>Pohlmann</surname> <given-names>A</given-names></name> <name><surname>Reimann</surname> <given-names>HM</given-names></name> <name><surname>Waiczies</surname> <given-names>H</given-names></name> <name><surname>Peper</surname> <given-names>E</given-names></name> <name><surname>Huelnhagen</surname> <given-names>T</given-names></name> <etal/></person-group>. <article-title>Advancing cardiovascular, neurovascular, and renal magnetic resonance imaging in small rodents using cryogenic radiofrequency coil technology</article-title>. <source>Front Pharmacol.</source> (<year>2015</year>) <volume>6</volume>:<fpage>255</fpage>. <pub-id pub-id-type="doi">10.3389/fphar.2015.00255</pub-id><pub-id pub-id-type="pmid">26617515</pub-id></citation></ref>
<ref id="B121">
<label>121.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dharmakumar</surname> <given-names>R</given-names></name> <name><surname>Arumana</surname> <given-names>JM</given-names></name> <name><surname>Tang</surname> <given-names>R</given-names></name> <name><surname>Harris</surname> <given-names>K</given-names></name> <name><surname>Zhang</surname> <given-names>Z</given-names></name> <name><surname>Li</surname> <given-names>D</given-names></name></person-group>. <article-title>Assessment of regional myocardial oxygenation changes in the presence of coronary artery stenosis with balanced SSFP imaging at 3.0 T: theory and experimental evaluation in canines</article-title>. <source>J Magn Reson Imaging</source> (<year>2008</year>) <volume>27</volume>:<fpage>1037</fpage>&#x02013;<lpage>45</lpage>. <pub-id pub-id-type="doi">10.1002/jmri.21345</pub-id><pub-id pub-id-type="pmid">18425840</pub-id></citation></ref>
<ref id="B122">
<label>122.</label>
<citation citation-type="book"><person-group person-group-type="editor"><name><surname>Poulo</surname> <given-names>L</given-names></name> <name><surname>Alon</surname> <given-names>L</given-names></name> <name><surname>Deniz</surname> <given-names>C</given-names></name> <name><surname>Haefner</surname> <given-names>R</given-names></name> <name><surname>Sodickson</surname> <given-names>D</given-names></name> <name><surname>Stoeckel</surname> <given-names>B</given-names></name> <etal/></person-group>. <article-title>A 32-Channel parallel exciter/amplifier transmit system for 7T imaging</article-title>. In: <person-group person-group-type="editor"><collab>ISMRM</collab></person-group>, editor. <source>Proceedings of the International Society for Magnetic Resonance Medicine 19</source>. <publisher-loc>Montr&#x000E9;al</publisher-loc> (<year>2011</year>). <fpage>p. 1867</fpage>.</citation></ref>
<ref id="B123">
<label>123.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lattanzi</surname> <given-names>R</given-names></name> <name><surname>Sodickson</surname> <given-names>DK</given-names></name></person-group>. <article-title>Ideal current patterns yielding optimal signal-to-noise ratio and specific absorption rate in magnetic resonance imaging: computational methods and physical insights</article-title>. <source>Magn Reson Med.</source> (<year>2012</year>) <volume>68</volume>:<fpage>286</fpage>&#x02013;<lpage>304</lpage>. <pub-id pub-id-type="doi">10.1002/mrm.23198</pub-id><pub-id pub-id-type="pmid">22127735</pub-id></citation></ref>
</ref-list>
<fn-group>
<fn fn-type="financial-disclosure"><p><bold>Funding.</bold> This work was supported (in part, TH and TN) by the DZHK (German Centre for Cardiovascular Research, partner site Berlin, BER 601) and by the BMBF (Federal Ministry of Education and Research, Berlin, Germany, FKZ 81Z6100161). TN received support by the BMBF (Federal Ministry of Education and Research, Berlin, Germany, FKZ 01QE1501B) and the EUROSTARS program (E! 9340 hearRT-4-EU).</p>
</fn>
</fn-group>
</back>
</article>
