<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="research-article" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xml:lang="EN">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Pediatr.</journal-id>
<journal-title>Frontiers in Pediatrics</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Pediatr.</abbrev-journal-title>
<issn pub-type="epub">2296-2360</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fped.2025.1655820</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Pediatrics</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Real-time ultrasound guidance improves neonatal umbilical venous catheter placement efficiency and reduces liver complications</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes"><name><surname>Tomaszkiewicz</surname><given-names>Anna</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="corresp" rid="cor1">&#x002A;</xref><uri xlink:href="https://loop.frontiersin.org/people/3115558/overview"/><role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/><role content-type="https://credit.niso.org/contributor-roles/data-curation/"/><role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/><role content-type="https://credit.niso.org/contributor-roles/investigation/"/><role content-type="https://credit.niso.org/contributor-roles/methodology/"/><role content-type="https://credit.niso.org/contributor-roles/software/"/><role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/></contrib>
<contrib contrib-type="author"><name><surname>Kruczek</surname><given-names>Piotr</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/1278299/overview" /><role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/><role content-type="https://credit.niso.org/contributor-roles/data-curation/"/><role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/><role content-type="https://credit.niso.org/contributor-roles/investigation/"/><role content-type="https://credit.niso.org/contributor-roles/supervision/"/><role content-type="https://credit.niso.org/contributor-roles/validation/"/><role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/></contrib>
<contrib contrib-type="author"><name><surname>Szyma&#x0144;ski</surname><given-names>Piotr</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/3234392/overview" /><role content-type="https://credit.niso.org/contributor-roles/investigation/"/><role content-type="https://credit.niso.org/contributor-roles/methodology/"/><role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/></contrib>
<contrib contrib-type="author"><name><surname>Walczak</surname><given-names>Krystian</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/3116287/overview" /><role content-type="https://credit.niso.org/contributor-roles/investigation/"/><role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/></contrib>
<contrib contrib-type="author"><name><surname>Teplicki</surname><given-names>Piotr</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/3233718/overview" /><role content-type="https://credit.niso.org/contributor-roles/data-curation/"/><role content-type="https://credit.niso.org/contributor-roles/investigation/"/><role content-type="https://credit.niso.org/contributor-roles/software/"/><role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/></contrib>
<contrib contrib-type="author"><name><surname>Sobczak</surname><given-names>Alina</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/1225973/overview" /><role content-type="https://credit.niso.org/contributor-roles/investigation/"/><role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/></contrib>
<contrib contrib-type="author"><name><surname>Mazela</surname><given-names>Jan</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/258088/overview" /><role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/><role content-type="https://credit.niso.org/contributor-roles/funding-acquisition/"/><role content-type="https://credit.niso.org/contributor-roles/project-administration/"/><role content-type="https://credit.niso.org/contributor-roles/resources/"/><role content-type="https://credit.niso.org/contributor-roles/supervision/"/><role content-type="https://credit.niso.org/contributor-roles/validation/"/><role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/></contrib>
</contrib-group>
<aff id="aff1"><label><sup>1</sup></label><institution>Department of Neonatology, Poznan University of Medical Sciences</institution>, <addr-line>Poznan</addr-line>, <country>Poland</country></aff>
<aff id="aff2"><label><sup>2</sup></label><institution>Department of Neonatology, R. Czerwiakowski Gynecology and Obstetrics Hospital</institution>, <addr-line>Krak&#x00F3;w</addr-line>, <country>Poland</country></aff>
<author-notes>
<fn fn-type="edited-by"><p><bold>Edited by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/423093/overview">Yogen Singh</ext-link>, University of California, Davis, United States</p></fn>
<fn fn-type="edited-by"><p><bold>Reviewed by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/926538/overview">Daniel Ibarra-R&#x00ED;os</ext-link>, Federico G&#x00F3;mez Children&#x0027;s Hospital, Mexico</p>
<p><ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/2311645/overview">Haoqiang Xie</ext-link>, Guangdong Medical University, China</p></fn>
<corresp id="cor1"><label>&#x002A;</label><bold>Correspondence:</bold> Anna Tomaszkiewicz <email>tomaszkiewicz.annamaria@gmail.com</email></corresp>
</author-notes>
<pub-date pub-type="epub"><day>21</day><month>10</month><year>2025</year></pub-date>
<pub-date pub-type="collection"><year>2025</year></pub-date>
<volume>13</volume><elocation-id>1655820</elocation-id>
<history>
<date date-type="received"><day>28</day><month>06</month><year>2025</year></date>
<date date-type="accepted"><day>30</day><month>09</month><year>2025</year></date>
</history>
<permissions>
<copyright-statement>&#x00A9; 2025 Tomaszkiewicz, Kruczek, Szyma&#x0144;ski, Walczak, Teplicki, Sobczak and Mazela.</copyright-statement>
<copyright-year>2025</copyright-year><copyright-holder>Tomaszkiewicz, Kruczek, Szyma&#x0144;ski, Walczak, Teplicki, Sobczak and Mazela</copyright-holder><license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the <ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by/4.0/">Creative Commons Attribution License (CC BY)</ext-link>. The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license>
</permissions>
<abstract><sec><title>Introduction</title>
<p>Umbilical venous catheters (UVCs) are essential in neonatal intensive care, yet blind insertion techniques remain common and increase the risk of malposition and liver injury. This study evaluated whether real-time ultrasound guidance improves UVC placement efficiency and safety.</p>
</sec><sec><title>Methods</title>
<p>We retrospectively analysed 305 neonates who underwent ultrasound-guided UVC placement between July 2023 and January 2025 in a tertiary neonatal unit. The primary outcome was successful tip placement in the subdiaphragmatic vestibule; the secondary outcome was acute catheter-related liver injury.</p>
</sec><sec><title>Results</title>
<p>Correct catheter placement was achieved in 86.56&#x0025; of cases, with a gradual improvement from 83.81&#x0025; to 89.12&#x0025; over time. Only one hepatic haematoma was observed, and no other acute complications occurred.</p>
</sec><sec><title>Discussion</title>
<p>Real-time ultrasound guidance significantly enhances the accuracy and safety of UVC insertion in neonates, minimising hepatic injury risk. Further research should assess its role in prolonged catheter monitoring.</p>
</sec>
</abstract>
<kwd-group>
<kwd>umbilical venous catheter</kwd>
<kwd>catheter-related complications</kwd>
<kwd>neonatal intensive care</kwd>
<kwd>central catheters</kwd>
<kwd>ultrasound</kwd>
</kwd-group><counts>
<fig-count count="4"/>
<table-count count="3"/><equation-count count="0"/><ref-count count="15"/><page-count count="7"/><word-count count="0"/></counts><custom-meta-wrap><custom-meta><meta-name>section-at-acceptance</meta-name><meta-value>Neonatology</meta-value></custom-meta></custom-meta-wrap>
</article-meta>
</front>
<body><sec id="s1" sec-type="intro"><label>1</label><title>Introduction</title>
<p>UVC catheters are commonly used in neonatal intensive care units to provide parenteral nutrition, deliver intravenous drugs, and obtain blood samples for laboratory tests in the absence of arterial access. Safe use of UVCs requires correct placement of the catheter tip and continuous monitoring for potential complications associated with its presence in the patient&#x0027;s body (<xref ref-type="bibr" rid="B1">1</xref>)<italic>.</italic></p>
<p>Numerous studies have confirmed that ultrasound is a more accurate method for assessing catheter tip position than conventional radiography (<xref ref-type="bibr" rid="B2">2</xref>&#x2013;<xref ref-type="bibr" rid="B4">4</xref>).</p>
<p>However, despite the use of ultrasound for the catheter tip localization, in most centres, the procedure itself is still performed blindly. This approach impacts insertion efficiency and increases the risk of complications.</p>
<p>In this study, we aimed to investigate whether real-time intra-procedural ultrasound assessment improves insertion efficiency and reduces acute catheter-related complications associated with navigation and manipulation during placement, particularly liver injury.</p>
</sec>
<sec id="s2" sec-type="methods"><label>2</label><title>Methods</title>
<sec id="s2a"><label>2.1</label><title>Patients</title>
<p>This study retrospectively analysed the medical records of patients admitted to a tertiary neonatal unit between July 2023 and January 2025. The study was conducted at a neonatal center in Krak&#x00F3;w, Poland, where approximately 1,700 infants are born annually including premature babies and children with congenital defects. The unit also admits neonates referred from other hospitals in the region and serves as a certified training site for specialization in neonatology Inclusion criteria included an attempt to insert a UVC catheter and a minimum hospital stay of three days. The primary indication for UVC placement was the anticipated need for parenteral nutrition for three or more days. Contraindications included omphalocele, gastroschisis, a planned abdominal surgical procedure within the first days of life, and the absence of a ductus venosus, which was either reported prenatally or identified postnatally during neonatal ultrasound prior to the procedure.</p>
</sec>
<sec id="s2b"><label>2.2</label><title>UVC insertion procedure</title>
<p>Before UVC insertion, ultrasound was performed to assess the anatomy of the portal tract and the ductus venosus, in order to determine the trajectory of the ductus venosus as it branches from the left portal vein. A wider angle between the ductus venosus and the left portal vein, combined with a wider ductus venosus, facilitated catheter advancement (<xref ref-type="fig" rid="F1">Figure&#x00A0;1</xref>). In this study, a difficult ductus venosus was defined as one with a smaller angle of origin and/or a narrower lumen (<xref ref-type="fig" rid="F2">Figure&#x00A0;2</xref>). Although this was considered a relative contraindication, all patients were included regardless of ductus venosus anatomy.</p>
<fig id="F1" position="float"><label>Figure 1</label>
<caption><p>Anatomical configuration characterized by a relatively wider angle between the ductus venosus and the left portal vein, together with a relatively wide ductus venosus lumen, which may facilitate smoother advancement of the catheter during insertion.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fped-13-1655820-g001.tif"><alt-text content-type="machine-generated">Ultrasound image displaying the liver of the newborn. Labeled structures include the ductus venosus, portal sinus, and umbilical vein. The labels are in yellow, with arrows pointing to each respective structure.</alt-text>
</graphic>
</fig>
<fig id="F2" position="float"><label>Figure 2</label>
<caption><p>Anatomical configuration in which the ductus venosus arises at a sharp angle and/or presents a narrower lumen, potentially increasing the technical complexity of catheter advancement.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fped-13-1655820-g002.tif"><alt-text content-type="machine-generated">Ultrasound image showing newborn anatomy with labeled structures. "Ductus venosus" is indicated by an arrow on the left, and "portal sinus" is marked on the right.</alt-text>
</graphic>
</fig>
<p>Two clinicians were involved in each insertion&#x2013; either a consultant neonatologist and a trained resident, or two trained residents. Residents were considered adequately trained after at least two months of daily ultrasound-guided catheter assessments during procedures or routine monitoring, and after performing a minimum of 25 UVC insertions. After incising the umbilical vein and advancing the catheter approximately 4&#x2013;5&#x2005;cm, further positioning was guided by ultrasound. The catheter was first visualized in the umbilical vein and then gradually advanced into the portal sinus under continuous ultrasound guidance, until reaching the ductus venosus. Correct catheter tip placement was defined as positioning in the subdiaphragmatic vestibule. The procedure was completed by securing the catheter. If difficulty arose in directing the catheter through the venous system into the subdiaphragmatic vestibule various manoeuvres were employed to achieve proper placement, such as posterior liver mobilization (<xref ref-type="bibr" rid="B5">5</xref>), gentle compression of the upper abdomen&#x2014;which involved applying titrated pressure to the liver with a transducer in order to compress the left portal vein, accentuate the caudal angulation of the right portal vein, and straighten the &#x201C;S-turn&#x201D; from the portal sinus to the ductus venosus, a manoeuvre most frequently used in our practice (<xref ref-type="bibr" rid="B6">6</xref>)&#x2014;or slight rotation of the patient to the right (<xref ref-type="bibr" rid="B7">7</xref>). All manoeuvres were performed under continuous ultrasound visualization, with the choice determined by whether the catheter was seen entering the liver parenchyma or deviating into the right portal vein&#x2014;information available only with real-time ultrasound. For imaging, either a microconvex transducer or a 12&#x2013;15&#x2005;MHz linear probe was used. The choice of probe depended primarily on the patient&#x0027;s body weight: the smaller microconvex transducer was used mainly in patients weighing less than 1,500&#x2005;g. The entire procedure, including the final catheter placement, was recorded. A longitudinal subcostal view was employed to visualize the catheter. <xref ref-type="fig" rid="F3">Figure&#x00A0;3</xref> shows the UVC during the procedure, prior to entering the ductus venosus, whereas <xref ref-type="fig" rid="F4">Figure&#x00A0;4</xref> demonstrates the catheter after successful advancement into the ductus venosus.</p>
<fig id="F3" position="float"><label>Figure 3</label>
<caption><p>Ultrasound image showing the umbilical venous catheter (UVC) during the procedure, positioned just before entry into the ductus venosus.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fped-13-1655820-g003.tif"><alt-text content-type="machine-generated">Ultrasound image showing the tip of an umbilical venous catheter (UVC) positioned in the portal sinus during the procedure.</alt-text>
</graphic>
</fig>
<fig id="F4" position="float"><label>Figure 4</label>
<caption><p>Ultrasound image showing the umbilical venous catheter (UVC) following successful advancement into the ductus venosus, confirming correct positioning.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fped-13-1655820-g004.tif"><alt-text content-type="machine-generated">Ultrasound image showing the tip of the umbilical venous catheter (UVC) in the correct position in the subdiaphragmatic vestibule. Yellow arrows and labels identify each structure.</alt-text>
</graphic>
</fig>
<p>In the <xref ref-type="sec" rid="s11">Supplementary Files</xref>, we have included a video showing the placement of a UVC under ultrasound guidance.</p>
<p>If initial placement was unsuccessful, the catheter was withdrawn, and an alternative vascular access was required. Ultrasound assessments were conducted every 24&#x2005;h to monitor for complications until catheter removal. The study&#x0027;s primary outcome was establishing the number of successfully placed catheters. The secondary outcome was the occurrence of mechanical liver injury related to catheter insertion and manipulation excluding thrombosis.</p>
</sec>
<sec id="s2c"><label>2.3</label><title>Statistics</title>
<p>The calculations were performed using TIBCO Statistica 13 and PQStat from PQStat Software. The level of significance was set to <italic>&#x03B1;</italic>&#x2009;&#x003D;&#x2009;0.05, and the result was considered statistically significant when <italic>p</italic>&#x2009;&#x003C;&#x2009;<italic>&#x03B1;</italic>.</p>
<p>To examine the relationship between categorical variables, the chi-square independence test or Fisher-Freeman-Halton test was calculated.</p>
<p>The normality of the distribution of variables was tested with the Shapiro&#x2013;Wilk test. To compare two groups of variables with a normal distribution and equal variance, the Student&#x0027;s <italic>t</italic>-test for unrelated samples was calculated. In the case of non-compliance with the normal distribution or for variables measured on an ordinal scale, the Mann&#x2013;Whitney test was calculated.</p>
</sec>
</sec>
<sec id="s3" sec-type="results"><label>3</label><title>Results</title>
<sec id="s3a"><label>3.1</label><title>Study groups</title>
<p>During the study period, ultrasound guided UVC placement was attempted in 310 neonates. Four patients were transferred to another hospital with surgical facilities, and one patient died. Of the transferred cases, three had congenital heart defects requiring cardiac surgery, and one had oesophageal atresia. The infant who died was an extremely premature neonate born at 24 weeks of gestation, who succumbed to congenital sepsis. These cases were excluded from the final analysis due to the inability to assess procedure-related complications. The final analysis included 305 patients.</p>
<p>The statistical analysis showed no differences between the group in which the catheter was successfully inserted and the group in which the catheter was not successfully inserted in terms of gender, body weight, Apgar score at 5&#x2005;min. The only statistically significant difference was the gestational age. The statistical results and group characteristics are summarized in <xref ref-type="table" rid="T1">Table&#x00A0;1</xref>.</p>
<table-wrap id="T1" position="float"><label>Table 1</label>
<caption><p>The statistical results and group characteristics.</p></caption>
<table frame="hsides" rules="groups">
<colgroup>
<col align="left"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
</colgroup>
<thead>
<tr>
<th valign="top" align="left">Variable</th>
<th valign="top" align="center">Successful UVC placement<break/>(<italic>n</italic>&#x2009;&#x003D;&#x2009;264)</th>
<th valign="top" align="center">Unsuccessful UVC placement<break/>(<italic>n</italic>&#x2009;&#x003D;&#x2009;41)</th>
<th valign="top" align="left"><italic>p</italic> value</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Sex (female)</td>
<td valign="top" align="center">120</td>
<td valign="top" align="center">18</td>
<td valign="top" align="center"><italic>p</italic>&#x2009;&#x003D;&#x2009;0,853</td>
</tr>
<tr>
<td valign="top" align="left">Birth weight (g), mean&#x2009;&#x00B1;&#x2009;SD</td>
<td valign="top" align="center">2746,5 (&#x00B1;703,7)</td>
<td valign="top" align="center">2956,8 (&#x00B1;747,3)</td>
<td valign="top" align="center"><italic>p</italic>&#x2009;&#x003D;&#x2009;0,0785</td>
</tr>
<tr>
<td valign="top" align="left">Birth weight (g), minimum</td>
<td valign="top" align="center">860</td>
<td valign="top" align="center">1,310</td>
<td valign="top" align="center"/>
</tr>
<tr>
<td valign="top" align="left">Birth weight (g), maximum</td>
<td valign="top" align="center">5,010</td>
<td valign="top" align="center">4,530</td>
<td valign="top" align="center"/>
</tr>
<tr>
<td valign="top" align="left">Gestational age (weeks), median</td>
<td valign="top" align="center">37</td>
<td valign="top" align="center">38</td>
<td valign="top" align="center"><italic>p</italic>&#x2009;&#x003D;&#x2009;0,019</td>
</tr>
<tr>
<td valign="top" align="left">Gestational age (weeks), maximum</td>
<td valign="top" align="center">41</td>
<td valign="top" align="center">41</td>
<td valign="top" align="center"/>
</tr>
<tr>
<td valign="top" align="left">Gestational age (weeks), minimum</td>
<td valign="top" align="center">27</td>
<td valign="top" align="center">30</td>
<td valign="top" align="center"/>
</tr>
<tr>
<td valign="top" align="left">Apgar score (5&#x2005;min), median</td>
<td valign="top" align="center">10</td>
<td valign="top" align="center">10</td>
<td valign="top" align="center"><italic>p</italic>&#x2009;&#x003D;&#x2009;0,745</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>The analysis of the reasons for catheter insertion took into account the most common ones, i.e., respiratory failure, prematurity, low body weight, hypoglycaemia and congenital anomalies (<xref ref-type="table" rid="T2">Table&#x00A0;2</xref>) and showed no statistical difference between the groups: <italic>p</italic>&#x2009;&#x003D;&#x2009;0.130.</p>
<table-wrap id="T2" position="float"><label>Table 2</label>
<caption><p>The reasons for catheter insertion.</p></caption>
<table frame="hsides" rules="groups">
<colgroup>
<col align="left"/>
<col align="center"/>
<col align="center"/>
</colgroup>
<thead>
<tr>
<th valign="top" align="left">Reason for UVC placement</th>
<th valign="top" align="center">Number of patients</th>
<th valign="top" align="center">Percentage</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Respiratory failure</td>
<td valign="top" align="center">82</td>
<td valign="top" align="center">26,89</td>
</tr>
<tr>
<td valign="top" align="left">Low birth weight</td>
<td valign="top" align="center">34</td>
<td valign="top" align="center">11,15</td>
</tr>
<tr>
<td valign="top" align="left">Prematurity</td>
<td valign="top" align="center">97</td>
<td valign="top" align="center">31,80</td>
</tr>
<tr>
<td valign="top" align="left">Hypoglycaemia</td>
<td valign="top" align="center">26</td>
<td valign="top" align="center">8,52</td>
</tr>
<tr>
<td valign="top" align="left">Congenital defects</td>
<td valign="top" align="center">17</td>
<td valign="top" align="center">5,57</td>
</tr>
<tr>
<td valign="top" align="left">Others</td>
<td valign="top" align="center">49</td>
<td valign="top" align="center">16,07</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
<sec id="s3b"><label>3.2</label><title>Succes rate and complications</title>
<p>The overall success rate for correct placement of UVC was 86.56&#x0025; and additional analysis over a six-month period revealed an increasing trend in insertion efficiency (<xref ref-type="table" rid="T3">Table&#x00A0;3</xref>).</p>
<table-wrap id="T3" position="float"><label>Table 3</label>
<caption><p>Efficacy of catheter insertion.</p></caption>
<table frame="hsides" rules="groups">
<colgroup>
<col align="left"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
</colgroup>
<thead>
<tr>
<th valign="top" align="left">Period</th>
<th valign="top" align="center">Number of patients</th>
<th valign="top" align="center">Number of UVC</th>
<th valign="top" align="center">Efficacy</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left"><bold>01.07.23&#x2013;31.12.24</bold></td>
<td valign="top" align="center"><bold>305</bold></td>
<td valign="top" align="center"><bold>264</bold></td>
<td valign="top" align="center"><bold>86,56&#x0025;</bold></td>
</tr>
<tr>
<td valign="top" align="left">01.07.23&#x2013;31.12.23</td>
<td valign="top" align="center">105</td>
<td valign="top" align="center">88</td>
<td valign="top" align="center">83,81&#x0025;</td>
</tr>
<tr>
<td valign="top" align="left">01.01.24&#x2013;30.06.24</td>
<td valign="top" align="center">99</td>
<td valign="top" align="center">86</td>
<td valign="top" align="center">86,87&#x0025;</td>
</tr>
<tr>
<td valign="top" align="left">01.07.24&#x2013;31.12.24</td>
<td valign="top" align="center">101</td>
<td valign="top" align="center">90</td>
<td valign="top" align="center">89,12&#x0025;</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="table-fn3a"><p>Bold text indicates effectiveness over the whole study period; effectiveness for 6-month periods are shown below.</p></fn>
</table-wrap-foot>
</table-wrap>
<p>However, using the Cochran&#x2013;Armitage trend test, this difference did not reach statistical significance (<italic>p</italic>&#x2009;&#x003D;&#x2009;0.2645). Analysis of catheter insertion complications identified one hepatic hematoma around the left portal vein branch, detected via ultrasound 24&#x2005;h post-insertion. In this case, the catheter tip was correctly positioned. No other liver complications were observed.</p>
</sec>
</sec>
<sec id="s4" sec-type="discussion"><label>4</label><title>Discussion</title>
<p>The 2020 guidelines of the European Society of Anaesthesiology (ESA) emphasize &#x201C;the global use of ultrasound&#x201D;, which formed the basis of this study, namely &#x201C;recognition of possible local disease; verification of the direction of guidewires and catheters in the vessel, verification of the correct position of the catheter tip; detection of possible postprocedural early and late complications&#x201D; (<xref ref-type="bibr" rid="B8">8</xref>). These principles are incorporated into our daily practice to improve catheter insertion efficiency and minimize procedure-related complications.</p>
<p>Pittiruti et al. stated that &#x201C;radiological methods (fluoroscopy, chest x-ray) no longer play any role in the insertion of vascular accesses in neonates and children&#x201D; (<xref ref-type="bibr" rid="B9">9</xref>), as supported by recent studies. In our study, we did not compare ultrasound with x ray because ultrasound is the sole method used in our department for assessing central catheters. Given the existing literature, routine x-ray assessment no longer appears justified. In all cases, we successfully visualized the catheter tip using ultrasound. We have achieved a high UVC placement efficiency in comparable to the large study by D&#x0027;Andrea (<xref ref-type="bibr" rid="B10">10</xref>) and to the smaller survey conducted by Kishigami et al. (<xref ref-type="bibr" rid="B6">6</xref>), demonstrating that real-time tip navigation significantly increases the likelihood of correct primary catheter positioning. Similar results and insertion techniques were reported by Kozyak (<xref ref-type="bibr" rid="B11">11</xref>). However, a randomized controlled trial conducted by Mishra (<xref ref-type="bibr" rid="B12">12</xref>) failed to show a statistically significant difference between ultrasound-guided and blind UVC insertion. It is worth noting that their study reported a much lower catheter placement efficiency compared to our findings and those of D&#x0027;Andrea (<xref ref-type="bibr" rid="B10">10</xref>).</p>
<p>Additionally, our study observed an increasing trend in the catheter insertion efficiency. Our centre is a resident training facility, and in each case, a resident assisted with the catheter placement. This aligns with findings from Rubortone (<xref ref-type="bibr" rid="B13">13</xref>), who demonstrated that ultrasound guidance and structured training improve the success rate of UVC placements. Although we noted a temporal increase in efficiency, the differences between the analysed time periods were not statistically significant.</p>
<p>Ultrasound-guided catheter positioning not only reduces malpositioning but also shortens procedure time, as confirmed in an randomized controlled trial by Kaur et al. (<xref ref-type="bibr" rid="B14">14</xref>). This efficiency may represent another significant advantage of this approach.</p>
<p>While we did not record procedure duration in our study, this represents a likely additional benefit of the technique.</p>
<p>The differences between successful and unsuccessful UVC groups suggest that catheter placement is more challenging in more mature neonates. We observed that the ductus venosus (DV) tends to be narrower in these infants.</p>
<p>In our study, DV anatomy was assessed prior to each procedure, and our observations indicate that beyond gestational age&#x2014;which was statistically significant&#x2014;the configuration of the DV has a substantial impact on the success of ultrasound-guided catheterization. However, further research is needed to objectively determine which anatomical variants of the DV make catheter placement particularly difficult. Such a detailed anatomical analysis was beyond the scope of this study.</p>
<p>The secondary endpoint of our study was early complications related to catheter insertion, particularly liver injury. Hematomas and thrombosis may occur if the catheter is inadvertently advanced into the liver parenchyma or becomes malpositioned (<xref ref-type="bibr" rid="B15">15</xref>). Although all catheters in our study were correctly positioned, various facilitating manoeuvres were employed to achieve optimal placement. We aimed to evaluate the safety of these manoeuvres, as inadvertent advancement into the liver parenchyma is sometimes unavoidable when the catheter initially follows an incorrect course rather than the ductus venosus. Without real-time visualization, the operator may remain unaware of such complications. Our findings suggest that, provided insertion is performed under continuous ultrasound guidance, the risk of liver injury is minimal. Data on complication rates prior to the introduction of ultrasound guidance are not available, as this method has been routinely employed in our department for many years. This study therefore summarizes outcomes from the most recent period of our practice. We did not assess late complications such as thrombosis, which we considered unrelated to the insertion technique. Importantly, no catheter-related infections attributable to the insertion technique (i.e., within 72&#x2005;h of catheter placement) were observed in our cohort.</p>
<p>Major strengths of our study are: large number of patients included in the analysis, prospectively established guideline for ultrasound guided UVC positioning.</p>
<p>The primary limitation of our study is that it was conducted in a single centre and utilized a retrospective design.</p>
<p>In conclusions, our study showed that ultrasound guided UVC placement is feasible, effective, safe and decrease number of potential complications. Further study is needed to establish if continuous ultrasound monitoring of UVC can allow for safe and longer utilization of such vascular catheters.</p>
</sec>
</body>
<back>
<sec id="s5" sec-type="data-availability"><title>Data availability statement</title>
<p>The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.</p>
</sec>
<sec id="s6" sec-type="ethics-statement"><title>Ethics statement</title>
<p>The studies involving humans were approved by Committee on Bioethics, Poznan University of Medical Sciences, approval number [KB 679/24]. The studies were conducted in accordance with the local legislation and institutional requirements. The ethics committee/institutional review board waived the requirement of written informed consent for participation from the participants or the participants&#x2019; legal guardians/next of kin because of retrospective character of the study and the fact that this method is a standard procedure in neonatal units.</p>
</sec>
<sec id="s7" sec-type="author-contributions"><title>Author contributions</title>
<p>AT: Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Software, Writing &#x2013; original draft. PK: Conceptualization, Data curation, Formal analysis, Investigation, Supervision, Validation, Writing &#x2013; review &#x0026; editing. PS: Investigation, Methodology, Writing &#x2013; original draft. KW: Investigation, Writing &#x2013; original draft. PT: Data curation, Investigation, Software, Writing &#x2013; original draft. AS: Investigation, Writing &#x2013; original draft. JM: Conceptualization, Funding acquisition, Project administration, Resources, Supervision, Validation, Writing &#x2013; review &#x0026; editing.</p>
</sec>
<sec id="s8" sec-type="funding-information"><title>Funding</title>
<p>The author(s) declare that no financial support was received for the research and/or publication of this article.</p>
</sec>
<sec id="s9" sec-type="COI-statement"><title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
<p>The handling editor YS declared a past co-authorship with the author(s) JLM.</p>
</sec>
<sec id="s10" sec-type="ai-statement"><title>Generative AI statement</title>
<p>The author(s) declare that no Generative AI was used in the creation of this manuscript.</p>
<p>Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.</p>
</sec>
<sec id="s12" sec-type="disclaimer"><title>Publisher&#x0027;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<sec id="s11" sec-type="supplementary-material"><title>Supplementary material</title>
<p>The Supplementary Material for this article can be found online at: <ext-link ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/fped.2025.1655820/full#supplementary-material">https://www.frontiersin.org/articles/10.3389/fped.2025.1655820/full&#x0023;supplementary-material</ext-link></p>
<supplementary-material id="SD1" content-type="local-data">
<media mimetype="video" mime-subtype="mp4" xlink:href="Video1.mp4"/></supplementary-material>
</sec>
<ref-list><title>References</title>
<ref id="B1"><label>1.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Abiramalatha</surname><given-names>T</given-names></name><name><surname>Kumar</surname><given-names>M</given-names></name><name><surname>Shabeer</surname><given-names>MP</given-names></name><name><surname>Thomas</surname><given-names>N</given-names></name></person-group>. <article-title>Advantages of being diligent: lessons learnt from umbilical venous catheterisation in neonates</article-title>. <source>BMJ Case Rep</source>. (<year>2016</year>) <volume>2016</volume>:<fpage>bcr2015214073</fpage>. <pub-id pub-id-type="doi">10.1136/bcr-2015-214073</pub-id><pub-id pub-id-type="pmid">26843419</pub-id></citation></ref>
<ref id="B2"><label>2.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Michel</surname><given-names>F</given-names></name><name><surname>Brevaut-Malaty</surname><given-names>V</given-names></name><name><surname>Pasquali</surname><given-names>R</given-names></name><name><surname>Thomachot</surname><given-names>L</given-names></name><name><surname>Vialet</surname><given-names>R</given-names></name><name><surname>Hassid</surname><given-names>S</given-names></name><etal/></person-group> <article-title>Comparison of ultrasound and x-ray in determining the position of umbilical venous catheters</article-title>. <source>Resuscitation</source>. (<year>2012</year>) <volume>83</volume>(<issue>6</issue>):<fpage>705</fpage>&#x2013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1016/j.resuscitation.2011.11.026</pub-id><pub-id pub-id-type="pmid">22155219</pub-id></citation></ref>
<ref id="B3"><label>3.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ponin</surname><given-names>L</given-names></name><name><surname>Ruangkit</surname><given-names>C</given-names></name><name><surname>Ruangwattanapaisarn</surname><given-names>N</given-names></name><name><surname>Nuntnarumit</surname><given-names>P</given-names></name></person-group>. <article-title>Real-time ultrasound to assess the umbilical catheter position in neonates: a randomized, controlled trial</article-title>. <source>J Perinatol</source>. (<year>2025</year>) <volume>45</volume>(<issue>2</issue>):<fpage>235</fpage>&#x2013;<lpage>41</lpage>. <pub-id pub-id-type="doi">10.1038/s41372-024-02128-6</pub-id><pub-id pub-id-type="pmid">39379732</pub-id></citation></ref>
<ref id="B4"><label>4.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sharma</surname><given-names>D</given-names></name><name><surname>Farahbakhsh</surname><given-names>N</given-names></name><name><surname>Tabatabaii</surname><given-names>SA</given-names></name></person-group>. <article-title>Role of ultrasound for central catheter tip localization in neonates: a review of the current evidence</article-title>. <source>J Matern Fetal Neonatal Med</source>. (<year>2019</year>) <volume>32</volume>(<issue>14</issue>):<fpage>2429</fpage>&#x2013;<lpage>37</lpage>. <pub-id pub-id-type="doi">10.1080/14767058.2018.1437135</pub-id><pub-id pub-id-type="pmid">29397784</pub-id></citation></ref>
<ref id="B5"><label>5.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Patel</surname><given-names>S</given-names></name><name><surname>Shannon</surname><given-names>D</given-names></name><name><surname>Eldridge</surname><given-names>W</given-names></name><name><surname>El-Ters</surname><given-names>N</given-names></name><name><surname>Hanford</surname><given-names>J</given-names></name><name><surname>Walker</surname><given-names>T</given-names></name><etal/></person-group> <article-title>Understanding umbilical venous catheter insertion practices through a prospective multicenter observational study</article-title>. <source>J Matern Fetal Neonatal Med</source>. (<year>2022</year>) <volume>35</volume>(<issue>25</issue>):<fpage>5043</fpage>&#x2013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1080/14767058.2021.1874908</pub-id><pub-id pub-id-type="pmid">33530795</pub-id></citation></ref>
<ref id="B6"><label>6.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kishigami</surname><given-names>M</given-names></name><name><surname>Shimokaze</surname><given-names>T</given-names></name><name><surname>Enomoto</surname><given-names>M</given-names></name><name><surname>Shibasaki</surname><given-names>J</given-names></name><name><surname>Toyoshima</surname><given-names>K</given-names></name></person-group>. <article-title>Ultrasound-guided umbilical venous catheter insertion with alignment of the umbilical vein and ductus Venosus</article-title>. <source>J of Ultrasound Medicine</source>. (<year>2020</year>) <volume>39</volume>(<issue>2</issue>):<fpage>379</fpage>&#x2013;<lpage>83</lpage>. <pub-id pub-id-type="doi">10.1002/jum.15106</pub-id></citation></ref>
<ref id="B7"><label>7.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kieran</surname><given-names>EA</given-names></name><name><surname>Laffan</surname><given-names>EE</given-names></name><name><surname>O&#x2019;Donnell</surname><given-names>CPF</given-names></name></person-group>. <article-title>Positioning newborns on their back or right side for umbilical venous catheter insertion</article-title>. <source>Acta Paediatr</source>. (<year>2016</year>) <volume>105</volume>(<issue>10</issue>):<fpage>e443</fpage>&#x2013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1111/apa.13525</pub-id><pub-id pub-id-type="pmid">27411081</pub-id></citation></ref>
<ref id="B8"><label>8.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lamperti</surname><given-names>M</given-names></name><name><surname>Biasucci</surname><given-names>DG</given-names></name><name><surname>Disma</surname><given-names>N</given-names></name><name><surname>Pittiruti</surname><given-names>M</given-names></name><name><surname>Breschan</surname><given-names>C</given-names></name><name><surname>Vailati</surname><given-names>D</given-names></name><etal/></person-group> <article-title>European Society of anaesthesiology guidelines on peri-operative use of ultrasound-guided for vascular access (PERSEUS vascular access)</article-title>. <source>Eur J Anaesthesiol</source>. (<year>2020</year>) <volume>37</volume>(<issue>5</issue>):<fpage>344</fpage>&#x2013;<lpage>76</lpage>. <pub-id pub-id-type="doi">10.1097/EJA.0000000000001180</pub-id><pub-id pub-id-type="pmid">32265391</pub-id></citation></ref>
<ref id="B9"><label>9.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pittiruti</surname><given-names>M</given-names></name><name><surname>Annetta</surname><given-names>MG</given-names></name><name><surname>D&#x2019;andrea</surname><given-names>V</given-names></name></person-group>. <article-title>Point-of-care ultrasound for vascular access in neonates and children</article-title>. <source>Eur J Pediatr</source>. (<year>2023</year>) <volume>183</volume>(<issue>3</issue>):<fpage>1073</fpage>&#x2013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1007/s00431-023-05378-2</pub-id><pub-id pub-id-type="pmid">38117353</pub-id></citation></ref>
<ref id="B10"><label>10.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>D&#x2019;Andrea</surname><given-names>V</given-names></name><name><surname>Prontera</surname><given-names>G</given-names></name><name><surname>Cota</surname><given-names>F</given-names></name><name><surname>Perri</surname><given-names>A</given-names></name><name><surname>Russo</surname><given-names>R</given-names></name><name><surname>Barone</surname><given-names>G</given-names></name><etal/></person-group> <article-title>Real-time ultrasound tip location reduces malposition and radiation exposure during umbilical venous catheter placement in neonates: a retrospective, observational study</article-title>. <source>Neonatology</source>. (<year>2025</year>) <volume>122</volume>(<issue>1</issue>):<fpage>32</fpage>&#x2013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1159/000538905</pub-id></citation></ref>
<ref id="B11"><label>11.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kozyak</surname><given-names>BW</given-names></name><name><surname>Fraga</surname><given-names>MV</given-names></name><name><surname>Juliano</surname><given-names>CE</given-names></name><name><surname>Bhombal</surname><given-names>S</given-names></name><name><surname>Munson</surname><given-names>DA</given-names></name><name><surname>Brandsma</surname><given-names>E</given-names></name><etal/></person-group> <article-title>Real-time ultrasound guidance for umbilical venous cannulation in neonates with congenital heart disease</article-title>. <source>Pediatr Crit Care Med</source>. (<year>2022</year>) <volume>23</volume>(<issue>5</issue>):<fpage>e257</fpage>&#x2013;<lpage>66</lpage>. <pub-id pub-id-type="doi">10.1097/PCC.0000000000002919</pub-id><pub-id pub-id-type="pmid">35250003</pub-id></citation></ref>
<ref id="B12"><label>12.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mishra</surname><given-names>P</given-names></name><name><surname>Mohanty</surname><given-names>PK</given-names></name><name><surname>Som</surname><given-names>TK</given-names></name><name><surname>Sahoo</surname><given-names>T</given-names></name><name><surname>Devi</surname><given-names>U</given-names></name><name><surname>Bag</surname><given-names>ND</given-names></name></person-group>. <article-title>Comparison of ultrasound-guided umbilical venous catheter insertion with blind method: a randomized controlled trial</article-title>. <source>Biomed Hub</source>. (<year>2024</year>) <volume>9</volume>(<issue>1</issue>):<fpage>1</fpage>&#x2013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1159/000535096</pub-id><pub-id pub-id-type="pmid">38179464</pub-id></citation></ref>
<ref id="B13"><label>13.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Rubortone</surname><given-names>SA</given-names></name><name><surname>Costa</surname><given-names>S</given-names></name><name><surname>Perri</surname><given-names>A</given-names></name><name><surname>D&#x2019;Andrea</surname><given-names>V</given-names></name><name><surname>Vento</surname><given-names>G</given-names></name><name><surname>Barone</surname><given-names>G</given-names></name></person-group>. <article-title>Real-time ultrasound for tip location of umbilical venous catheter in neonates: a pre/post intervention study</article-title>. <source>Ital J Pediatr</source>. (<year>2021</year>) <volume>47</volume>(<issue>1</issue>):<fpage>68</fpage>. <pub-id pub-id-type="doi">10.1186/s13052-021-01014-7</pub-id><pub-id pub-id-type="pmid">33736669</pub-id></citation></ref>
<ref id="B14"><label>14.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sulemanji</surname><given-names>M</given-names></name><name><surname>Vakili</surname><given-names>K</given-names></name><name><surname>Zurakowski</surname><given-names>D</given-names></name><name><surname>Tworetzky</surname><given-names>W</given-names></name><name><surname>Fishman</surname><given-names>SJ</given-names></name><name><surname>Kim</surname><given-names>HB</given-names></name></person-group>. <article-title>Umbilical venous catheter malposition is associated with necrotizing enterocolitis in premature infants</article-title>. <source>Neonatology</source>. (<year>2017</year>) <volume>111</volume>(<issue>4</issue>):<fpage>337</fpage>&#x2013;<lpage>43</lpage>. <pub-id pub-id-type="doi">10.1159/000451022</pub-id><pub-id pub-id-type="pmid">28092913</pub-id></citation></ref>
<ref id="B15"><label>15.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kim</surname><given-names>MJ</given-names></name><name><surname>Yoo</surname><given-names>SY</given-names></name><name><surname>Jeon</surname><given-names>TY</given-names></name><name><surname>Kim</surname><given-names>JH</given-names></name><name><surname>Kim</surname><given-names>YJ</given-names></name></person-group>. <article-title>Imaging of umbilical venous catheter-related hepatic complications in neonates</article-title>. <source>J Korean Soc Radiol</source>. (<year>2023</year>) <volume>84</volume>(<issue>3</issue>):<fpage>586</fpage>. <pub-id pub-id-type="doi">10.3348/jksr.2022.0056</pub-id><pub-id pub-id-type="pmid">37324991</pub-id></citation></ref></ref-list>
</back>
</article>