<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="review-article" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xml:lang="EN">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Pediatr.</journal-id>
<journal-title>Frontiers in Pediatrics</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Pediatr.</abbrev-journal-title>
<issn pub-type="epub">2296-2360</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fped.2025.1632216</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Pediatrics</subject>
<subj-group>
<subject>Review</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Telemetric intracranial pressure monitoring in patients with hydrocephalus: a systematic literature review</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author"><name><surname>Yangi</surname><given-names>Kivanc</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/2822343/overview"/><role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/><role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/><role content-type="https://credit.niso.org/contributor-roles/methodology/"/><role content-type="https://credit.niso.org/contributor-roles/resources/"/><role content-type="https://credit.niso.org/contributor-roles/validation/"/><role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/><role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/></contrib>
<contrib contrib-type="author"><name><surname>Gulick</surname><given-names>Daniel W.</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/3166702/overview" /><role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/><role content-type="https://credit.niso.org/contributor-roles/methodology/"/><role content-type="https://credit.niso.org/contributor-roles/software/"/><role content-type="https://credit.niso.org/contributor-roles/validation/"/><role content-type="https://credit.niso.org/contributor-roles/visualization/"/><role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/><role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/></contrib>
<contrib contrib-type="author"><name><surname>Calderon Valero</surname><given-names>Carlos E.</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref><role content-type="https://credit.niso.org/contributor-roles/data-curation/"/><role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/><role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/></contrib>
<contrib contrib-type="author"><name><surname>Gok</surname><given-names>Egemen</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/2878031/overview" />
<role content-type="https://credit.niso.org/contributor-roles/data-curation/"/><role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/><role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/></contrib>
<contrib contrib-type="author"><name><surname>D&#x0027;Saachs</surname><given-names>Michael C.</given-names></name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/3085457/overview" />
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/><role content-type="https://credit.niso.org/contributor-roles/investigation/"/><role content-type="https://credit.niso.org/contributor-roles/software/"/><role content-type="https://credit.niso.org/contributor-roles/visualization/"/><role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/></contrib>
<contrib contrib-type="author"><name><surname>Bassi</surname><given-names>Ishaan</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref><role content-type="https://credit.niso.org/contributor-roles/software/"/><role content-type="https://credit.niso.org/contributor-roles/visualization/"/><role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/></contrib>
<contrib contrib-type="author"><name><surname>On</surname><given-names>Thomas J.</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/2663255/overview" /><role content-type="https://credit.niso.org/contributor-roles/investigation/"/><role content-type="https://credit.niso.org/contributor-roles/software/"/><role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/></contrib>
<contrib contrib-type="author" corresp="yes"><name><surname>Preul</surname><given-names>Mark C.</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="corresp" rid="cor1">&#x002A;</xref><uri xlink:href="https://loop.frontiersin.org/people/62816/overview" /><role content-type="https://credit.niso.org/contributor-roles/funding-acquisition/"/><role content-type="https://credit.niso.org/contributor-roles/project-administration/"/><role content-type="https://credit.niso.org/contributor-roles/resources/"/><role content-type="https://credit.niso.org/contributor-roles/supervision/"/><role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/></contrib>
</contrib-group>
<aff id="aff1"><label><sup>1</sup></label><institution>The Loyal and Edith Davis Neurosurgical Research Laboratory, Department of Neurosurgery, Barrow Neurological Institute, St. Joseph&#x2019;s Hospital and Medical Center</institution>, <addr-line>Phoenix</addr-line>, <addr-line>AZ</addr-line>, <country>United States</country></aff>
<aff id="aff2"><label><sup>2</sup></label><institution>School of Electrical, Computer, and Energy Engineering, Arizona State University</institution>, <addr-line>Tempe</addr-line>, <addr-line>AZ</addr-line>, <country>United States</country></aff>
<aff id="aff3"><label><sup>3</sup></label><institution>School of Biological and Health Systems Engineering, Arizona State University</institution>, <addr-line>Tempe, AZ</addr-line>, <country>United States</country></aff>
<author-notes>
<fn fn-type="edited-by"><p><bold>Edited by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/2880167/overview">Nan Bao</ext-link>, Shanghai Jiao Tong University, China</p></fn>
<fn fn-type="edited-by"><p><bold>Reviewed by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/76646/overview">Brandon Peter Lucke-Wold</ext-link>, University of Florida, United States </p>
<p><ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/2057653/overview">Roberto Henzi</ext-link>, Temuco Catholic University, Chile </p>
<p><ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/2545423/overview">Casper Schwartz Riedel</ext-link>, University of Copenhagen, Denmark</p></fn>
<corresp id="cor1"><label>&#x002A;</label><bold>Correspondence:</bold> Mark C. Preul <email>Neuropub@barrowneuro.org</email></corresp>
</author-notes>
<pub-date pub-type="epub"><day>10</day><month>10</month><year>2025</year></pub-date>
<pub-date pub-type="collection"><year>2025</year></pub-date>
<volume>13</volume><elocation-id>1632216</elocation-id>
<history>
<date date-type="received"><day>20</day><month>05</month><year>2025</year></date>
<date date-type="accepted"><day>15</day><month>09</month><year>2025</year></date>
</history>
<permissions>
<copyright-statement>&#x00A9; 2025 Yangi, Gulick, Calderon Valero, Gok, D&#x0027;Saachs, Bassi, On and Preul.</copyright-statement>
<copyright-year>2025</copyright-year><copyright-holder>Yangi, Gulick, Calderon Valero, Gok, D&#x0027;Saachs, Bassi, On and Preul</copyright-holder><license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the <ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by/4.0/">Creative Commons Attribution License (CC BY)</ext-link>. The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license>
</permissions>
<abstract><sec><title>Objective</title>
<p>This systematic literature review sought to examine telemetric intracranial pressure (ICP) monitoring devices, evaluate their operating principles and applications in hydrocephalus management, and highlight their advantages over traditional ICP monitoring methods.</p>
</sec><sec><title>Materials and methods</title>
<p>A comprehensive search using Medical Subject Headings terms was conducted in the Medline (via PubMed), Scopus, and Embase databases for articles published in English. In accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, a strict selection process was followed. Three reviewers independently examined the full texts of the selected articles.</p>
</sec><sec><title>Results</title>
<p>A total of 300 articles were retrieved, with 52 meeting the inclusion criteria after removing duplicates and noneligible studies. Telemetric ICP monitoring has been studied since the 1980s, but research remained limited until 2011 (16 [31&#x0025;] studies), although it increased significantly thereafter (36 [69&#x0025;] studies). The Raumedic Neurovent-P-tel was introduced in 2009, and 22 of the 36 studies published since 2011 focused solely on Raumedic devices. Likewise, after the Miethke Sensor Reservoir was released in 2015, interest in this field grew, with 9 studies evaluating Miethke devices between 2017 and 2024. Since 2019, 4 studies have reported experiences using both Raumedic and Miethke devices. Among the total of 52 studies, 11 (21&#x0025;) focused on pediatric patients, 10 (19&#x0025;) focused on adults, 22 (42&#x0025;) included both age groups, and 9 (17&#x0025;) did not specify patient age.</p>
</sec><sec><title>Conclusions</title>
<p>Telemetric ICP monitoring has emerged as a valuable tool in managing hydrocephalus, offering continuous, noninvasive monitoring that enhances diagnostic accuracy and treatment adjustments. This review highlights the increasing adoption of these devices and their potential to improve clinical outcomes while reducing hospital admissions and invasive interventions. Despite challenges such as high initial costs and sensor drift, technological advancements and further research could enhance their reliability and expand their applications in neurosurgery.</p>
</sec>
</abstract>
<kwd-group>
<kwd>hydrocephalus</kwd>
<kwd>intracranial pressure</kwd>
<kwd>intracranial pressure monitoring</kwd>
<kwd>intracranial pressure sensor</kwd>
<kwd>shunt valve</kwd>
<kwd>telemetry</kwd>
</kwd-group><contract-sponsor id="cn001">Newsome Chair in Neurosurgery Research</contract-sponsor><contract-sponsor id="cn002">Barrow Neurological Foundation</contract-sponsor><counts>
<fig-count count="8"/>
<table-count count="3"/><equation-count count="0"/><ref-count count="109"/><page-count count="26"/><word-count count="0"/></counts><custom-meta-wrap><custom-meta><meta-name>section-at-acceptance</meta-name><meta-value>Pediatric Surgery</meta-value></custom-meta></custom-meta-wrap>
</article-meta>
</front>
<body><sec id="s1"><label>1</label><title>Introduction</title>
<p>Hydrocephalus is a neurological condition characterized by the accumulation of cerebrospinal fluid (CSF) within the cerebral ventricular system (<xref ref-type="bibr" rid="B1">1</xref>). The global prevalence of hydrocephalus is estimated at approximately 85 cases per 100,000 individuals, though this figure varies substantially across age groups. In children, the prevalence is around 88 per 100,000, while it drops to approximately 11 per 100,000 in the adult population. In contrast, the elderly population exhibits a markedly higher prevalence, reaching nearly 175 per 100,000, and exceeding 400 per 100,000 among individuals over the age of 80, largely due to the increased incidence of normal pressure hydrocephalus (NPH) in later life (<xref ref-type="bibr" rid="B2">2</xref>).</p>
<p>Hydrocephalus pathogenesis is complex and multifactorial, involving disturbances in CSF flow, absorption, or, in rarer cases, overproduction. Obstruction of CSF pathways, impaired absorption into the venous system, or excessive CSF secretion can all contribute to the development of hydrocephalus (<xref ref-type="bibr" rid="B2">2</xref>). In 1913, Walter Dandy introduced the fundamental classification of hydrocephalus into communicating and noncommunicating (obstructive) types; however, various alternative classification systems have since emerged (<xref ref-type="bibr" rid="B3">3</xref>, <xref ref-type="bibr" rid="B4">4</xref>). For clinical clarity, adult hydrocephalus is often categorized into four main subtypes: obstructive, communicating, hypersecretory, and NPH (<xref ref-type="bibr" rid="B2">2</xref>). In pediatric populations, congenital or developmental hydrocephalus is more commonly encountered.</p>
<p>Notably, even with treatment, hydrocephalus carries a mortality rate of up to 3&#x0025; in children, highlighting the critical importance of early diagnosis and appropriate intervention (<xref ref-type="bibr" rid="B5">5</xref>). Despite advances in endoscopic techniques such as endoscopic third ventriculostomy (ETV) and choroid plexus cauterization, ventriculoperitoneal shunting remains the first-line surgical treatment in most cases (<xref ref-type="bibr" rid="B2">2</xref>). However, although shunt placement remains the mainstay of surgical treatment for hydrocephalus, it is not without complications. In pediatric patients, the event-free survival rate following ventricular shunt placement is reported to be approximately 70&#x0025; at 1 year, dropping to around 40&#x0025; at 10 years (<xref ref-type="bibr" rid="B5">5</xref>). Additionally, shunt infection rates, which correlate with longer follow-up durations, can reach 15&#x0025;&#x2013;30&#x0025;, depending on patient and procedural factors. Achieving shunt independence has been documented in only 3&#x0025;&#x2013;9&#x0025; of cases, although reported rates vary widely across the literature due to heterogeneity in study populations and definitions (<xref ref-type="bibr" rid="B5">5</xref>). Given the considerable risk of shunt failure or the need for revision surgery, close postoperative surveillance is essential.</p>
<p>Shunt systems divert excess CSF from the brain to other body parts, such as the peritoneum, helping to regulate intracranial pressure (ICP) (<xref ref-type="bibr" rid="B6">6</xref>&#x2013;<xref ref-type="bibr" rid="B8">8</xref>). However, monitoring the ICP and determining the correct valve adjustments to prevent CSF under-drainage or over-drainage can be challenging (<xref ref-type="bibr" rid="B9">9</xref>). Furthermore, after shunt surgery, assessing shunt dysfunction, ICP elevation, and the potential role of ICP in the patient&#x0027;s clinical condition is crucial. This process can be time-consuming and lead to unnecessary diagnostic tests and imaging. Most centers rely on patient-reported symptoms, which can be subtle or absent. Symptoms like headaches may not be adequately expressed or verbalized, particularly in specific patient populations, such as infants or those with limited communication abilities. Additionally, reliance on repeated computed tomography (CT) increases the frequency of outpatient visits, raises healthcare costs, and exposes infants to unnecessary ionizing radiation (<xref ref-type="bibr" rid="B10">10</xref>, <xref ref-type="bibr" rid="B11">11</xref>).</p>
<p>Consequently, ICP monitoring has become a valuable diagnostic parameter for CSF disorders. Nonetheless, most methods of ICP monitoring are invasive or necessitate hospitalization, which increases the utilization of hospital resources (<xref ref-type="bibr" rid="B12">12</xref>). To address this issue, telemetric (wireless) sensors have emerged as safe, accurate, and cost-effective ICP monitoring tools. Although Mackay first proposed the concept of ICP monitoring with telemetric devices in 1961 (<xref ref-type="bibr" rid="B13">13</xref>), and the initial 2 prototypes were documented in the literature in 1967 (<xref ref-type="bibr" rid="B14">14</xref>, <xref ref-type="bibr" rid="B15">15</xref>), the popularity of these devices significantly increased with the introduction of the Neurovent-P-tel telemetric device (Raumedic AG, Helmbrechts, Germany) in 2009. This device could accurately measure ICP with negligible zero-point drift and provide long-term performance (<xref ref-type="bibr" rid="B16">16</xref>&#x2013;<xref ref-type="bibr" rid="B18">18</xref>). With technological advancements and the introduction of other telemetric devices to the market, such as sensor reservoirs, telemetric sensors present a promising alternative, offering the potential for real-time, noninvasive ICP monitoring in patients with hydrocephalus and other CSF pathologies.</p>
<p>We systematically reviewed the current literature on the use of telemetric sensors to measure ICP in patients with hydrocephalus. The study aimed to examine telemetric ICP monitoring devices, assess their operational principles and clinical utility, compare them with traditional methods, and identify current limitations and future research directions.</p>
</sec>
<sec id="s2"><label>2</label><title>Materials and methods</title>
<sec id="s2a"><label>2.1</label><title>Search strategy</title>
<p>Systematic searches were performed in the Medline (via PubMed), Scopus, and Embase databases, screening articles from inception to March 18, 2025, using the following keywords: [(Intracranial Pressure) OR (Intracranial Pressures) OR (Pressure, Intracranial) OR (Pressures, Intracranial) OR (Subarachnoid Pressure) OR (Pressures, Subarachnoid) OR (Pressure, Subarachnoid) OR (Subarachnoid Pressures) OR (Intracerebral Pressure) OR (Intracerebral Pressures) OR (Pressure, Intracerebral) OR (Pressures, Intracerebral)] AND [(Telemetric monitoring) OR (Telemetric) OR (Telemetrics) OR (Telemetries) OR (Telemetry) OR (Telemeter) OR (Telesensors) OR (Telemetric sensor) OR (Teletransducer) OR (Telesensor)] AND [(Hydrocephalus) OR (Hydrocephaly) OR (Communicating Hydrocephalus) OR (Hydrocephalus, Communicating) OR (Congenital Hydrocephalus) OR (Hydrocephalus, Congenital) OR (Obstructive Hydrocephalus) OR (Hydrocephalus, Obstructive) OR (Post-Traumatic Hydrocephalus) OR (Hydrocephalus, Post-Traumatic) OR (Post Traumatic Hydrocephalus) OR (Hydrocephalus Ex-Vacuo) OR (Hydrocephalus Ex Vacuo) OR (Hydrocephalus Ex-Vacuos) OR (Aqueductal Stenosis) OR (Aqueductal Stenoses) OR (Stenoses, Aqueductal) OR (Stenosis, Aqueductal) OR (Cerebral Ventriculomegaly) OR (Cerebral Ventriculomegalies) OR (Ventriculomegalies, Cerebral) OR (Ventriculomegaly, Cerebral) OR (Fetal Cerebral Ventriculomegaly) OR (Cerebral Ventriculomegalies, Fetal) OR (Cerebral Ventriculomegaly, Fetal) OR (Fetal Cerebral Ventriculomegalies) OR (Ventriculomegalies, Fetal Cerebral) OR (Ventriculomegaly, Fetal Cerebral)]. The Boolean operators &#x201C;AND&#x201D; and &#x201C;OR&#x201D; linked these Medical Subject Heading terms, ensuring maximum comprehensiveness.</p>
</sec>
<sec id="s2b"><label>2.2</label><title>Eligibility criteria</title>
<p>Our inclusion criteria focused on original research articles using telemetric devices for ICP measurement in patients with hydrocephalus. Articles were excluded if they lacked all 3 of the following key components: telemetric devices, ICP measurement, and application in patients with hydrocephalus. Review articles, errata, retracted papers, editorials, duplicate publications, and studies without accessible full texts or those not available in English were also excluded.</p>
</sec>
<sec id="s2c"><label>2.3</label><title>Study selection</title>
<p>Three independent reviewers (D.W.G., C.E.C.V., K.Y.) conducted the article screening process, considering only English-language articles. Duplicates were removed, and a strict selection procedure was followed in alignment with the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines (<xref ref-type="bibr" rid="B19">19</xref>). Additionally, the reference lists of all included articles were reviewed by 2 independent reviewers (C.E.C.V., K.Y.), as recommended by systematic review guidelines (<xref ref-type="bibr" rid="B20">20</xref>). Disagreements during the screening were resolved through discussion, and a consensus was reached among all reviewers (D.W.G., C.E.C.V., K.Y.) to include 52 articles in the study.</p>
</sec>
</sec>
<sec id="s3" sec-type="results"><label>3</label><title>Results</title>
<p>A total of 300 articles were retrieved in the initial search. After removing 167 duplicate papers, 14 review articles, 6 editorials, and 2 articles with inaccessible full texts, 111 articles remained. Among these, 59 articles were excluded for not meeting the inclusion criteria. Upon completion of the screening, 52 articles were identified as eligible and included in the study (<xref ref-type="table" rid="T1">Table&#x00A0;1</xref>) (<xref ref-type="bibr" rid="B16">16</xref>, <xref ref-type="bibr" rid="B21">21</xref>&#x2013;<xref ref-type="bibr" rid="B71">71</xref>). The selection process, which adhered to the PRISMA guidelines, is shown in <xref ref-type="fig" rid="F1">Figure&#x00A0;1</xref>.</p>
<table-wrap id="T1" position="float"><label>Table 1</label>
<caption><p>Studies using telemetric ICP measurement devices in the management of patients with hydrocephalus.</p></caption>
<table frame="hsides" rules="groups">
<colgroup>
<col align="left"/>
<col align="left"/>
<col align="left"/>
<col align="left"/>
</colgroup>
<thead>
<tr>
<th valign="top" align="left">Study, year</th>
<th valign="top" align="center">Type of telemetric ICP sensor</th>
<th valign="top" align="center">Population</th>
<th valign="top" align="center">Goal</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Pedersen et al. (2024) (<xref ref-type="bibr" rid="B21">21</xref>)</td>
<td valign="top" align="left">Neurovent-P-tel (Raumedic AG, Helmbrechts, Germany) and Miethke Sensor Reservoir/M.scio (Christoph Miethke GmbH &#x0026; Co KG, Potsdam, Germany)</td>
<td valign="top" align="left">Pediatric</td>
<td valign="top" align="left">Evaluation of family and patient perceptions of telemetric ICP monitoring</td>
</tr>
<tr>
<td valign="top" align="left">Pandit et al. (2024) (<xref ref-type="bibr" rid="B22">22</xref>)</td>
<td valign="top" align="left">Miethke Sensor Reservoir/M.scio (Christoph Miethke GmbH &#x0026; Co KG, Potsdam, Germany)</td>
<td valign="top" align="left">Adult</td>
<td valign="top" align="left">Evaluation of whether telesensor use is associated with differences in service and financial demands compared with nontelemetric reservoirs</td>
</tr>
<tr>
<td valign="top" align="left">Hornsh&#x00F8;j Pedersen et al. (2024) (<xref ref-type="bibr" rid="B23">23</xref>)</td>
<td valign="top" align="left">Neurovent-P-tel (Raumedic AG, Helmbrechts, Germany)</td>
<td valign="top" align="left">Pediatric</td>
<td valign="top" align="left">Systematic investigation of patient and parent perceptions of the utility of telemetric ICP systems, as well as hospital contact history, to evaluate potential costs and benefits of telemetric ICP monitoring in pediatric patients with CSF disorders</td>
</tr>
<tr>
<td valign="top" align="left">Jirlow et al. (2023) (<xref ref-type="bibr" rid="B24">24</xref>)</td>
<td valign="top" align="left">Miethke Sensor Reservoir/M.scio (Christoph Miethke GmbH &#x0026; Co KG, Potsdam, Germany)</td>
<td valign="top" align="left">Adult</td>
<td valign="top" align="left">Examination of the role of telemetric ICP monitoring in aiding the assessment of shunt function and necessary adjustments</td>
</tr>
<tr>
<td valign="top" align="left">Pennacchietti et al. (2023) (<xref ref-type="bibr" rid="B25">25</xref>)</td>
<td valign="top" align="left">Miethke Sensor Reservoir (Christoph Miethke GmbH &#x0026; Co KG, Potsdam, Germany)</td>
<td valign="top" align="left">Adult and pediatric</td>
<td valign="top" align="left">Evaluation and definition of a maneuver protocol and its related ICP changes in an outpatient setting</td>
</tr>
<tr>
<td valign="top" align="left">Banks et al. (2022) (<xref ref-type="bibr" rid="B26">26</xref>)</td>
<td valign="top" align="left">Miethke Sensor Reservoir/M.scio (Christoph Miethke GmbH &#x0026; Co KG, Potsdam, Germany)</td>
<td valign="top" align="left">Unspecified</td>
<td valign="top" align="left">Characterization of telesensor cost-effectiveness and impact on service demand</td>
</tr>
<tr>
<td valign="top" align="left">Korfias et al. (2021) (<xref ref-type="bibr" rid="B27">27</xref>)</td>
<td valign="top" align="left">Neurovent-P-tel (Raumedic AG, Helmbrechts, Germany)</td>
<td valign="top" align="left">Adult</td>
<td valign="top" align="left">Demonstration that ICP telemetry enables long-term ICP recordings, reduces hospitalization duration, and lowers overall healthcare costs</td>
</tr>
<tr>
<td valign="top" align="left">Banks et al. (2021) (<xref ref-type="bibr" rid="B28">28</xref>)</td>
<td valign="top" align="left">Miethke Sensor Reservoir/M.scio (Christoph Miethke GmbH &#x0026; Co KG, Potsdam, Germany)</td>
<td valign="top" align="left">Unspecified</td>
<td valign="top" align="left">Investigation of the impact of telesensor implantation on reducing service demand and achieving net financial savings</td>
</tr>
<tr>
<td valign="top" align="left">Khan et al. (2021) (<xref ref-type="bibr" rid="B29">29</xref>)</td>
<td valign="top" align="left">A noninvasive ICP measuring reservoir</td>
<td valign="top" align="left">Adult</td>
<td valign="top" align="left">Investigation of the utility of postneuroendoscopy ICP monitoring using a new-generation, noninvasive ICP measuring reservoir</td>
</tr>
<tr>
<td valign="top" align="left">Kommer et al. (2021) (<xref ref-type="bibr" rid="B30">30</xref>)</td>
<td valign="top" align="left">Raumedic telemetric ICP probe (details not available)</td>
<td valign="top" align="left">Adult and pediatric</td>
<td valign="top" align="left">Determination of whether short recordings were reflective of longer periods of monitoring and assessment of the safety of one-off measurement</td>
</tr>
<tr>
<td valign="top" align="left">Rot et al. (2020) (<xref ref-type="bibr" rid="B31">31</xref>)</td>
<td valign="top" align="left">Neurovent-P-tel (Raumedic AG, Helmbrechts, Germany) and Miethke Sensor Reservoir (Christoph Miethke GmbH &#x0026; Co KG, Potsdam, Germany)</td>
<td valign="top" align="left">Adult</td>
<td valign="top" align="left">Analysis of the differences in ICP values measured with Neurovent-P-tel probe, Miethke Sensor Reservoir, and EVD</td>
</tr>
<tr>
<td valign="top" align="left">Pennacchietti et al. (2020) (<xref ref-type="bibr" rid="B32">32</xref>)</td>
<td valign="top" align="left">Neurovent-P-tel (Raumedic AG, Helmbrechts, Germany) and Miethke Sensor Reservoir (Christoph Miethke GmbH &#x0026; Co KG, Potsdam, Germany)</td>
<td valign="top" align="left">Adult and pediatric</td>
<td valign="top" align="left">Evaluation of the effectiveness of telemetric ICP measurement in enhancing the clinical management of shunted patients with complex hydrocephalus</td>
</tr>
<tr>
<td valign="top" align="left">Pedersen et al. (2020) (<xref ref-type="bibr" rid="B33">33</xref>)</td>
<td valign="top" align="left">Neurovent-P-tel (Raumedic AG, Helmbrechts, Germany)</td>
<td valign="top" align="left">Pediatric</td>
<td valign="top" align="left">Evaluation of the experience of using long-term telemetric ICP monitoring in pediatric patients</td>
</tr>
<tr>
<td valign="top" align="left">M&#x00FC;ller et al. (2019) (<xref ref-type="bibr" rid="B34">34</xref>)</td>
<td valign="top" align="left">Neurovent-P-tel (Raumedic AG, Helmbrechts, Germany)</td>
<td valign="top" align="left">Adult</td>
<td valign="top" align="left">Proposal of a maneuver for outpatient telemetric ICP recording and evaluation of its test-retest reliability</td>
</tr>
<tr>
<td valign="top" align="left">Norager et al. (2019) (<xref ref-type="bibr" rid="B35">35</xref>)</td>
<td valign="top" align="left">Neurovent-P-tel (Raumedic AG, Helmbrechts, Germany) and Miethke Sensor Reservoir (Christoph Miethke GmbH &#x0026; Co KG, Potsdam, Germany)</td>
<td valign="top" align="left">Adult and pediatric</td>
<td valign="top" align="left">Identification of appropriate uses of Neurovent-P-tel and Miethke Sensor Reservoir</td>
</tr>
<tr>
<td valign="top" align="left">Tschan et al. (2019) (<xref ref-type="bibr" rid="B36">36</xref>)</td>
<td valign="top" align="left">Neurovent-P-tel (Raumedic AG, Helmbrechts, Germany)</td>
<td valign="top" align="left">Adult and pediatric</td>
<td valign="top" align="left">Report on a new home setup for telemonitoring ICP and assess the usefulness of these devices, particularly for patients living far from hospitals</td>
</tr>
<tr>
<td valign="top" align="left">Norager et al. (2018) (<xref ref-type="bibr" rid="B37">37</xref>)</td>
<td valign="top" align="left">Neurovent-P-tel (Raumedic AG, Helmbrechts, Germany)</td>
<td valign="top" align="left">Adult and pediatric</td>
<td valign="top" align="left">Investigation of the clinical performance, technical durability, survival time, and drift of the telemetric ICP sensor</td>
</tr>
<tr>
<td valign="top" align="left">Antes et al. (2018) (<xref ref-type="bibr" rid="B38">38</xref>)</td>
<td valign="top" align="left">Miethke Sensor Reservoir (Christoph Miethke GmbH &#x0026; Co KG, Potsdam, Germany)</td>
<td valign="top" align="left">Adult and pediatric</td>
<td valign="top" align="left">Evaluation of the telemetric device for individually adjusting shunt valves on the basis of ICP measurements</td>
</tr>
<tr>
<td valign="top" align="left">Thompson et al. (2018) (<xref ref-type="bibr" rid="B39">39</xref>)</td>
<td valign="top" align="left">Miethke Sensor Reservoir (Christoph Miethke GmbH &#x0026; Co KG, Potsdam, Germany)</td>
<td valign="top" align="left">Unspecified</td>
<td valign="top" align="left">Assessment of the financial benefits of telemetric device implantation</td>
</tr>
<tr>
<td valign="top" align="left">Thompson et al. (2018) (<xref ref-type="bibr" rid="B40">40</xref>)</td>
<td valign="top" align="left">Miethke Sensor Reservoir (Christoph Miethke GmbH &#x0026; Co KG, Potsdam, Germany)</td>
<td valign="top" align="left">Unspecified</td>
<td valign="top" align="left">Evaluation of the reliability of the telemetric device in managing patients with complex hydrocephalus</td>
</tr>
<tr>
<td valign="top" align="left">Ertl et al. (2017) (<xref ref-type="bibr" rid="B41">41</xref>)</td>
<td valign="top" align="left">Aesculap-Miethke Sensor Reservoir (Christoph Miethke GmbH &#x0026; Co KG, Potsdam, Germany)</td>
<td valign="top" align="left">Adult</td>
<td valign="top" align="left">Evaluation of the usefulness of the sensor reservoir in reliably measuring ICP changes in patients with a shunt system</td>
</tr>
<tr>
<td valign="top" align="left">Barber et al. (2017) (<xref ref-type="bibr" rid="B42">42</xref>)</td>
<td valign="top" align="left">Neurovent-P-tel (Raumedic AG, Helmbrechts, Germany)</td>
<td valign="top" align="left">Pediatric</td>
<td valign="top" align="left">Examination of the overall cost of telemetric device implantation and its impact on reducing hospital admissions, and collection and analysis of patient and family feedback</td>
</tr>
<tr>
<td valign="top" align="left">Antes et al. (2016) (<xref ref-type="bibr" rid="B16">16</xref>)</td>
<td valign="top" align="left">Neurovent-P-tel (Raumedic AG, Helmbrechts, Germany)</td>
<td valign="top" align="left">Adult and pediatric</td>
<td valign="top" align="left">Examination of technical aspects, handling, possibilities of data analysis, and efficiency of the telemetric probe in clinical routine</td>
</tr>
<tr>
<td valign="top" align="left">Andresen et al. (2016) (<xref ref-type="bibr" rid="B43">43</xref>)</td>
<td valign="top" align="left">Neurovent-P or Neurovent-P-tel intraparenchymal probes (Raumedic AG, Helmbrechts, Germany)</td>
<td valign="top" align="left">Adult and pediatric</td>
<td valign="top" align="left">Quantification of the effects of postural changes on ICP in healthy and ill subjects</td>
</tr>
<tr>
<td valign="top" align="left">Maeske et al. (2016) (<xref ref-type="bibr" rid="B44">44</xref>)</td>
<td valign="top" align="left">Neurovent-P-tel (Raumedic AG, Helmbrechts, Germany)</td>
<td valign="top" align="left">Adult and pediatric</td>
<td valign="top" align="left">Examination of ICP measurements in mobile patients in their everyday environment</td>
</tr>
<tr>
<td valign="top" align="left">Andresen et al. (2015) (<xref ref-type="bibr" rid="B47">47</xref>)</td>
<td valign="top" align="left">Neurovent-P or Neurovent-P-tel (Raumedic AG, Helmbrechts, Germany)</td>
<td valign="top" align="left">Adult and pediatric</td>
<td valign="top" align="left">Investigation of ICP in different body postures in both healthy and ill subjects</td>
</tr>
<tr>
<td valign="top" align="left">Farahmand et al. (2015) (<xref ref-type="bibr" rid="B45">45</xref>)</td>
<td valign="top" align="left">Intraparenchymatous ICP sensor (Raumedic AG, Helmbrechts, Germany)</td>
<td valign="top" align="left">Adult</td>
<td valign="top" align="left">Analysis of the ICP and ICP wave amplitude at different shunt settings and body positions in patients with hydrocephalus</td>
</tr>
<tr>
<td valign="top" align="left">Raffalli-Ebezant et al. (2014) (<xref ref-type="bibr" rid="B46">46</xref>)</td>
<td valign="top" align="left">Neurovent-P-tel (Raumedic AG, Helmbrechts, Germany)</td>
<td valign="top" align="left">Pediatric</td>
<td valign="top" align="left">Evaluation of the management, cost analysis, and early clinical outcomes of telemetric ICP monitor use</td>
</tr>
<tr>
<td valign="top" align="left">Antes et al. (2014) (<xref ref-type="bibr" rid="B48">48</xref>)</td>
<td valign="top" align="left">Neurovent-P-tel (Raumedic AG, Helmbrechts, Germany)</td>
<td valign="top" align="left">Adult and pediatric</td>
<td valign="top" align="left">Providing sufficient ICP data for long-term observation and early detection of endoscopy failures and complications</td>
</tr>
<tr>
<td valign="top" align="left">Lilja et al. (2014) (<xref ref-type="bibr" rid="B49">49</xref>)</td>
<td valign="top" align="left">Neurovent-P-tel (Raumedic AG, Helmbrechts, Germany)</td>
<td valign="top" align="left">Adult and pediatric</td>
<td valign="top" align="left">Evaluation of the clinical utility of long-term telemetric ICP monitoring and identification of its advantages and challenges to guide future improvements in the technology</td>
</tr>
<tr>
<td valign="top" align="left">Freimann et al. (2014) (<xref ref-type="bibr" rid="B50">50</xref>)</td>
<td valign="top" align="left">Neurovent-P-tel (Raumedic AG, Helmbrechts, Germany)</td>
<td valign="top" align="left">Adult and pediatric</td>
<td valign="top" align="left">Presentation of first experiences with telemetric ICP-guided valve adjustments in cases with the combination of an adjustable differential pressure valve and adjustable gravitational unit</td>
</tr>
<tr>
<td valign="top" align="left">Antes et al. (2014) (<xref ref-type="bibr" rid="B51">51</xref>)</td>
<td valign="top" align="left">Neurovent-P-tel (Raumedic AG, Helmbrechts, Germany)</td>
<td valign="top" align="left">Adult and pediatric</td>
<td valign="top" align="left">Evaluation of clinical and radiological findings after insertion of an intraparenchymal telemetric ICP monitor</td>
</tr>
<tr>
<td valign="top" align="left">Tschan et al. (2013) (<xref ref-type="bibr" rid="B52">52</xref>)</td>
<td valign="top" align="left">Neurovent-P-tel (Raumedic AG, Helmbrechts, Germany)</td>
<td valign="top" align="left">Pediatric</td>
<td valign="top" align="left">Presentation of first long-term experience with the telemetric intraparenchymal probe in children</td>
</tr>
<tr>
<td valign="top" align="left">Elixmann et al. (2012) (<xref ref-type="bibr" rid="B53">53</xref>)</td>
<td valign="top" align="left">Neurovent-P-tel (Raumedic AG, Helmbrechts, Germany)</td>
<td valign="top" align="left">Adult</td>
<td valign="top" align="left">Provide insight into the differential pressure across a hydrocephalus valve in everyday life</td>
</tr>
<tr>
<td valign="top" align="left">Welschehold et al. (2012) (<xref ref-type="bibr" rid="B54">54</xref>)</td>
<td valign="top" align="left">Neurovent-P-tel (Raumedic AG, Helmbrechts, Germany)</td>
<td valign="top" align="left">Adult and pediatric</td>
<td valign="top" align="left">Presentation of first clinical experiences with a new telemetric ICP monitoring device</td>
</tr>
<tr>
<td valign="top" align="left">Tschan et al. (2011) (<xref ref-type="bibr" rid="B55">55</xref>)</td>
<td valign="top" align="left">Neurovent-P-tel (Raumedic AG, Helmbrechts, Germany)</td>
<td valign="top" align="left">Adult and pediatric</td>
<td valign="top" align="left">Presentation of experience with a new telemetric intraparenchymal pressure probe, with the transducer placed over the calvaria and beneath the galea</td>
</tr>
<tr>
<td valign="top" align="left">Frim and Lathrop (2000) (<xref ref-type="bibr" rid="B56">56</xref>)</td>
<td valign="top" align="left">TeleSensor (Radionics, Inc, Burlington, MA, USA)</td>
<td valign="top" align="left">Adult and pediatric</td>
<td valign="top" align="left">Assessment of the <italic>in vivo</italic> impact of variable pressure valve adjustments on ICP changes using a noninvasive telemonitor, serving as an alternative to radiographic confirmation and a method for validating ICP changes</td>
</tr>
<tr>
<td valign="top" align="left">Frim and Goumnervoa (2000) (<xref ref-type="bibr" rid="B57">57</xref>)</td>
<td valign="top" align="left">TeleSensor (models ICP-M4 and ICP-M3) (Radionics, Inc, Burlington, MA, USA)</td>
<td valign="top" align="left">Adult and pediatric</td>
<td valign="top" align="left">Integration of telemonitoring devices with various shunt systems to evaluate the performance characteristics of these valve systems in relation to IVP at different head elevation levels</td>
</tr>
<tr>
<td valign="top" align="left">Richard et al. (1999) (<xref ref-type="bibr" rid="B58">58</xref>)</td>
<td valign="top" align="left">A custom ICP sensor designed by Telemeasurement GmbH, Aachen, Germany</td>
<td valign="top" align="left">Adult and pediatric</td>
<td valign="top" align="left">Highlighting the advantages of telesensors, including their improved assessment of shunt dysfunction and detection of marginal CSF pressure increases, alongside their practicality, simplicity in outpatient measurements, and potential to reduce the reliance on costly CT or MRI</td>
</tr>
<tr>
<td valign="top" align="left">Wayenberg (1998) (<xref ref-type="bibr" rid="B59">59</xref>)</td>
<td valign="top" align="left">RTT (Rotterdam, Netherlands)</td>
<td valign="top" align="left">Pediatric</td>
<td valign="top" align="left">Obtaining accurate information about ICP and changes in cerebral compliance across a wide range of clinical conditions without relying on invasive techniques</td>
</tr>
<tr>
<td valign="top" align="left">Munshi et al. (1998) (<xref ref-type="bibr" rid="B60">60</xref>)</td>
<td valign="top" align="left">TeleSensor (Radionics, Inc, Burlington, MA, USA)</td>
<td valign="top" align="left">Adult and pediatric</td>
<td valign="top" align="left">Examination of the <italic>in vivo</italic> IVP dynamics of ventriculopleural shunts using a commercially available implantable telemonitor</td>
</tr>
<tr>
<td valign="top" align="left">Miyake et al. (1997) (<xref ref-type="bibr" rid="B71">71</xref>)</td>
<td valign="top" align="left">Osaka telesensor (Nagano Keiki Seisakusyo Co Ltd, Tokyo, Japan)</td>
<td valign="top" align="left">Unspecified</td>
<td valign="top" align="left">Investigation of the clinical usefulness of new ventriculoperitoneal shunting with an Osaka telesensor</td>
</tr>
<tr>
<td valign="top" align="left">Frim and Goumnervoa (1997) (<xref ref-type="bibr" rid="B61">61</xref>)</td>
<td valign="top" align="left">TeleSensor device (Radionics, Inc, Burlington, MA, USA)</td>
<td valign="top" align="left">Adult</td>
<td valign="top" align="left">Examination and documentation of IVP dynamics in an adult after endoscopic third ventriculocisternostomy performed as treatment for hydrocephalus associated with aqueductal stenosis</td>
</tr>
<tr>
<td valign="top" align="left">Longatti and Carteri (1994) (<xref ref-type="bibr" rid="B70">70</xref>)</td>
<td valign="top" align="left">Telemetric ICP detector (details not available)</td>
<td valign="top" align="left">Unspecified</td>
<td valign="top" align="left">Measurement of acute changes in ICP after temporarily closing the shunt valve to determine whether the shunt remained necessary</td>
</tr>
<tr>
<td valign="top" align="left">Wayenberg et al. (1993) (<xref ref-type="bibr" rid="B62">62</xref>)</td>
<td valign="top" align="left">RTT (Rotterdam, Netherlands)</td>
<td valign="top" align="left">Pediatric</td>
<td valign="top" align="left">Demonstration that the RTT provided accurate and reproducible measurements of ICP</td>
</tr>
<tr>
<td valign="top" align="left">Kamiryo et al. (1991) (<xref ref-type="bibr" rid="B63">63</xref>)</td>
<td valign="top" align="left">NS10 (Nagano Keiki Seisakusho, Japan)</td>
<td valign="top" align="left">Pediatric</td>
<td valign="top" align="left">Report of a case of hydrocephalus showing slit ventricle syndrome after multiple shunt revisions treated with a programmable pressure valve; ICP was monitored with a telemetric sensor</td>
</tr>
<tr>
<td valign="top" align="left">Yamaguchi et al. (1990) (<xref ref-type="bibr" rid="B64">64</xref>)</td>
<td valign="top" align="left">Telemetric ICP sensor (details not available)</td>
<td valign="top" align="left">Unspecified</td>
<td valign="top" align="left">Measurement of ventricular fluid pressure in 10 hydrocephalic patients before and after ventriculoperitoneal shunts</td>
</tr>
<tr>
<td valign="top" align="left">Chapman et al. (1990) (<xref ref-type="bibr" rid="B65">65</xref>)</td>
<td valign="top" align="left">TeleSensor (Radionics, Inc, Burlington, MA, USA)</td>
<td valign="top" align="left">Adult and pediatric</td>
<td valign="top" align="left">Description of the disruption of postural IVP regulation caused by shunt placement and the impact of different shunt systems and antisiphon devices on this issue</td>
</tr>
<tr>
<td valign="top" align="left">G&#x00FC;&#x00E7;er et al. (1988) (<xref ref-type="bibr" rid="B66">66</xref>)</td>
<td valign="top" align="left">A permanently implanted epidural sensor</td>
<td valign="top" align="left">Unspecified</td>
<td valign="top" align="left">Discussion of the stability, safety, and accuracy of the sensor, along with the causes of drift and potential solutions, and presentation of a comparison with other epidural telemetric monitoring systems</td>
</tr>
<tr>
<td valign="top" align="left">Maas and de Jong (1986) (<xref ref-type="bibr" rid="B67">67</xref>)</td>
<td valign="top" align="left">RTT (Rotterdam, Netherlands)</td>
<td valign="top" align="left">Pediatric</td>
<td valign="top" align="left">Presentation of the problems encountered in the development of the device and report on results obtained with the RTT in clinical use</td>
</tr>
<tr>
<td valign="top" align="left">Chapman et al. (1984) (<xref ref-type="bibr" rid="B69">69</xref>)</td>
<td valign="top" align="left">Custom telemetric monitoring system</td>
<td valign="top" align="left">Unspecified</td>
<td valign="top" align="left">Proposition of an alternative to EVD (telemetric ICP monitoring) for the management of postoperative hydrocephalus</td>
</tr>
<tr>
<td valign="top" align="left">Nulsen et al. (1980) (<xref ref-type="bibr" rid="B68">68</xref>)</td>
<td valign="top" align="left">Custom telemetric device</td>
<td valign="top" align="left">Pediatric</td>
<td valign="top" align="left">Description of the capacity to monitor ICP accurately by telemetry</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="table-fn1"><p>CSF, cerebrospinal fluid; CT, computed tomography; EVD, external ventricular drain; ICP, intracranial pressure; IVP, intraventricular pressure; MRI, magnetic resonance imaging; RTT, Rotterdam Teletransducer.</p></fn>
</table-wrap-foot>
</table-wrap>
<fig id="F1" position="float"><label>Figure 1</label>
<caption><p>Flow diagram documenting the study selection process. Used with permission from Barrow Neurological Institute, Phoenix, Arizona.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fped-13-1632216-g001.tif"><alt-text content-type="machine-generated">Flowchart depicting the identification, screening, and inclusion of studies. 300 records identified from databases; 167 duplicates removed. 133 records screened; 2 excluded due to lack of full text. 131 reports sought for retrieval; 79 excluded for reviews, editorials, or unmet criteria. 52 reports assessed and included in the review.</alt-text>
</graphic>
</fig>
<p>Although the role of telemetric ICP monitoring devices in managing patients with hydrocephalus has been studied since 1980, we found that there were relatively few publications before 2011 (16 of 52, 31&#x0025;), with earlier studies mainly involving devices such as the Rotterdam Teletransducer (RTT) (Erasmus University, Rotterdam, Netherlands) (<italic>n</italic>&#x2009;&#x003D;&#x2009;3), Radionics TeleSensor (Radionics, Inc, Burlington, MA, USA), (<italic>n</italic>&#x2009;&#x003D;&#x2009;5), and other telemetry-based sensors (<italic>n</italic>&#x2009;&#x003D;&#x2009;8). However, from 2011 onward, there was a notable and steady increase in research on telemetric ICP devices each year (36 of 52, 69&#x0025;) (<xref ref-type="fig" rid="F2">Figure&#x00A0;2</xref>).</p>
<fig id="F2" position="float"><label>Figure 2</label>
<caption><p><bold>(A)</bold> Distribution of 52 studies describing the use of telemetric devices for intracranial pressure measurement in the management of patients with hydrocephalus by year and brand. <bold>(B)</bold> Distribution of the telemetric studies by patient population (pediatric, <italic>n</italic>&#x2009;&#x003D;&#x2009;11; adult, <italic>n</italic>&#x2009;&#x003D;&#x2009;10; adult and pediatric, <italic>n</italic>&#x2009;&#x003D;&#x2009;22; unspecified, <italic>n</italic>&#x2009;&#x003D;&#x2009;9). Miethke, Miethke Sensor Reservoir; Radionics, Radionics TeleSensor; Raumedic, Raumedic Neurovent-P-tel; RTT, Rotterdam Teletransducer. Used with permission from Barrow Neurological Institute, Phoenix, Arizona.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fped-13-1632216-g002.tif"><alt-text content-type="machine-generated">Bar charts illustrate the number of publications on the use of telemetric intracranial pressure monitoring devices in the management of patients with hydrocephalus. Chart A: Publications by year from 1980 to 2024, categorized by manufacturer (Raumedic, Miethke, Raumedic + Miethke, Radionics, RTT, Other). A peak occurs in 2014. Chart B: Publications by patient group (Pediatric, Adult, Adult + Pediatric, Unspecified), with the highest for Adult + Pediatric.</alt-text>
</graphic>
</fig>
<p>Following the introduction of the Neurovent-P-tel in 2009, there was a notable increase in related publications, with Raumedic telemetric devices examined in 22 of the 36 studies published since 2011. Similarly, the number of publications increased after the introduction of the Miethke Sensor Reservoir (Christoph Miethke GmbH &#x0026; Co KG, Potsdam, Germany) in 2015, with many studies beginning to evaluate the effectiveness of the Miethke devices (<italic>n</italic>&#x2009;&#x003D;&#x2009;9). Since 2019, several centers have reported their experiences using Raumedic and Miethke devices (<italic>n</italic>&#x2009;&#x003D;&#x2009;4). On the other hand, since 2011, only 1 study has examined telemetric devices other than Raumedic or Miethke (<xref ref-type="fig" rid="F2">Figure&#x00A0;2</xref>).</p>
<p>Among 52 studies that used telemetric devices for ICP measurement in managing patients with hydrocephalus, 11 (21&#x0025;) focused exclusively on pediatric patients, 10 (19&#x0025;) focused on adult patients, and 22 (42&#x0025;) included both adult and pediatric patient groups. In 9 (17&#x0025;) of the studies, the age groups of the included patients were not specified.</p>
<p>Furthermore, to ensure clinical correlation, the most clinically relevant studies were examined (<xref ref-type="table" rid="T2">Table&#x00A0;2</xref>). Among the 42 clinically relevant studies published between 1980 and 2024, the pooled mean (SD) patient age was 44.03 (23.98) years. Of these studies, 8 focused exclusively on pediatric patients, 7 on adults, 23 included both age groups, and 4 did not specify the patient population. In the overall distribution of etiologies reported across the included studies, the most frequently observed categories were unspecified hydrocephalus (<italic>n</italic>&#x2009;&#x003D;&#x2009;281), NPH (<italic>n</italic>&#x2009;&#x003D;&#x2009;274), and idiopathic intracranial hypertension (<italic>n</italic>&#x2009;&#x003D;&#x2009;202). These were followed by obstructive hydrocephalus (<italic>n</italic>&#x2009;&#x003D;&#x2009;175), posthemorrhagic hydrocephalus (<italic>n</italic>&#x2009;&#x003D;&#x2009;81), congenital hydrocephalus (<italic>n</italic>&#x2009;&#x003D;&#x2009;76), and shunt-related disorders (<italic>n</italic>&#x2009;&#x003D;&#x2009;61). Less commonly reported etiologies included tumor-related hydrocephalus (<italic>n</italic>&#x2009;&#x003D;&#x2009;31), trauma- or stress-associated hydrocephalus (<italic>n</italic>&#x2009;&#x003D;&#x2009;27), cystic malformations (<italic>n</italic>&#x2009;&#x003D;&#x2009;14), craniosynostosis (<italic>n</italic>&#x2009;&#x003D;&#x2009;13), Chiari malformation (<italic>n</italic>&#x2009;&#x003D;&#x2009;6), and postinfectious hydrocephalus (<italic>n</italic>&#x2009;&#x003D;&#x2009;4) (<xref ref-type="fig" rid="F3">Figure&#x00A0;3</xref>).</p>
<table-wrap id="T2" position="float"><label>Table 2</label>
<caption><p>Summary of clinically relevant studies on telemetric ICP monitoring (1980&#x2013;2024): population, CSF disorder types, device details, and outcomes.</p></caption>
<table frame="hsides" rules="groups">
<colgroup>
<col align="left"/>
<col align="left"/>
<col align="left"/>
<col align="left"/>
<col align="left"/>
<col align="left"/>
<col align="left"/>
<col align="left"/>
<col align="left"/>
<col align="left"/>
</colgroup>
<thead>
<tr>
<th valign="top" align="left">Study</th>
<th valign="top" align="center">Population</th>
<th valign="top" align="center">Age, yrs</th>
<th valign="top" align="center">No. of pts, by type of CSF disorder</th>
<th valign="top" align="center">Timing of device placement</th>
<th valign="top" align="center">Device(s) used</th>
<th valign="top" align="center">Functional duration of the device</th>
<th valign="top" align="center">Follow-up duration</th>
<th valign="top" align="center">Shunt or device revision</th>
<th valign="top" align="center">Complication(s)</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Pedersen et al. (2024) (<xref ref-type="bibr" rid="B21">21</xref>)</td>
<td valign="top" align="left">Pediatric: 16<xref ref-type="table-fn" rid="table-fn3"><sup>a</sup></xref></td>
<td valign="top" align="left">&#x003C;4: 1 pt; 4&#x2013;8: 4 pts; 9&#x2013;12: 4 pts; 13&#x2013;16: 3 pts; unspecified: 4 pts</td>
<td valign="top" align="left">Obstructive hydrocephalus: 4; trauma and stress related: 1; hydrocephalus, unspecified: 12; IIH: 4; postinfectious hydrocephalus: 1; congenital hydrocephalus: 6; Chiari malformation: 2; craniosynostosis: 2</td>
<td valign="top" align="left">Diagnostic evaluation: 2/41; postoperative surveillance: 39/41</td>
<td valign="top" align="left">Neurovent-P-tel: 40/41; Miethke SR: 1/41</td>
<td valign="top" align="left">Mean (range): 337.6 (12&#x2013;1,290) days</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">Device revision/removal: 32/41 (no longer functional: 17/32; patient/parent request: 1/32; pain/irritation: 4/32; minor wound defect: 1/32; liquor accumulation: 1/32; infection: 2/32; unknown: 6/32)</td>
<td valign="top" align="left">Skin irritation: 7; cosmetic issues: 6; pain due to sensor: 7</td>
</tr>
<tr>
<td valign="top" align="left">Pandit et al. (2024) (<xref ref-type="bibr" rid="B22">22</xref>)</td>
<td valign="top" align="left">Adult: 136 (telesensor: 74; control: 62 controls)</td>
<td valign="top" align="left">Mean (SD): 38.3 (14.7)</td>
<td valign="top" align="left">IIH: 16; congenital hydrocephalus: 20; tumor-related hydrocephalus: 2; NPH: 2<xref ref-type="table-fn" rid="table-fn10"><sup>f</sup></xref></td>
<td valign="top" align="left">Initial shunt placement: 26/48; shunt revision: 28/48</td>
<td valign="top" align="left">Miethke SR</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">Minimum 2 years</td>
<td valign="top" align="left">Mean (SD) shunt revision count per pt: telesensor group, 0.27 (0.61); control group, 0.71 (1.64)</td>
<td valign="top" align="left">NS</td>
</tr>
<tr>
<td valign="top" align="left">Hornsh&#x00F8;j Pedersen et al. (2024) (<xref ref-type="bibr" rid="B23">23</xref>)</td>
<td valign="top" align="left">Pediatric: 3</td>
<td valign="top" align="left">Mean (SD): 5.0 (3.36)</td>
<td valign="top" align="left">Hydrocephalus, unspecified: 3</td>
<td valign="top" align="left">Postoperative surveillance: 4/4</td>
<td valign="top" align="left">Neurovent-P-tel</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">1 pt &#x003E;5 years; 2 pts &#x003C;1 year</td>
<td valign="top" align="left">Device revision: 1</td>
<td valign="top" align="left">Fear of teasing at school: 1; cosmetic challenges: 1; wire wrapping during sleep: 1</td>
</tr>
<tr>
<td valign="top" align="left">Jirlow et al. (2023) (<xref ref-type="bibr" rid="B24">24</xref>)</td>
<td valign="top" align="left">Adult: 14</td>
<td valign="top" align="left">Mean (range): 30.3 (21&#x2013;50)</td>
<td valign="top" align="left">IIH: 3; obstructive hydrocephalus: 9; trauma and stress related: 2</td>
<td valign="top" align="left">Primary shunt surgery: 8/14; revision surgery: 5/14; stand-alone placement: 1/14</td>
<td valign="top" align="left">Miethke SR</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">8 months to 5 years</td>
<td valign="top" align="left">Shunt revisions: 5</td>
<td valign="top" align="left">Shunt dysfunction: 4; shunt infection: 1</td>
</tr>
<tr>
<td valign="top" align="left">Pennacchietti et al. (2023) (<xref ref-type="bibr" rid="B25">25</xref>)</td>
<td valign="top" align="left">Adult and pediatric: 17</td>
<td valign="top" align="left">Median (range): shunt group, 15.8 (4&#x2013;35.2); stand-alone group, 11.9 (3.6&#x2013;17.7)</td>
<td valign="top" align="left">IIH: 8; congenital hydrocephalus: 4; posthemorrhagic hydrocephalus: 2; obstructive hydrocephalus: 1; tumor-related hydrocephalus: 1; craniosynostosis: 1</td>
<td valign="top" align="left">Primary shunt surgery: 9/17; revision surgery: 2/17; stand-alone placement: 6/17</td>
<td valign="top" align="left">Miethke SR</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
</tr>
<tr>
<td valign="top" align="left">Korfias et al. (2021) (<xref ref-type="bibr" rid="B27">27</xref>)</td>
<td valign="top" align="left">Adult: 22</td>
<td valign="top" align="left">Mean (range): 40.8 (21&#x2013;65)</td>
<td valign="top" align="left">IIH: 10; NPH: 3; hydrocephalus, unspecified: 6; obstructive hydrocephalus: 2; shunt-related disorders: 1</td>
<td valign="top" align="left">Diagnostic evaluation</td>
<td valign="top" align="left">Neurovent-P-tel</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">No device revision; shunt-related revisions: 3</td>
<td valign="top" align="left">Local cerebral edema around catheter: 1; epileptic seizure due to small hematoma after device removal: 1; shunt-related complications: 3</td>
</tr>
<tr>
<td valign="top" align="left">Kommer et al. (2021) (<xref ref-type="bibr" rid="B30">30</xref>)</td>
<td valign="top" align="left">Adult and pediatric: 11</td>
<td valign="top" align="left">Median (range): 14.2 (2.4&#x2013;46.2)</td>
<td valign="top" align="left">IIH: 4; cystic malformation: 2; congenital hydrocephalus: 2; craniosynostosis: 1; obstructive hydrocephalus: 2</td>
<td valign="top" align="left">Postoperative surveillance</td>
<td valign="top" align="left">Neurovent-P-tel</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NA (all inpatients)</td>
<td valign="top" align="left">NA</td>
<td valign="top" align="left">No device-related complications reported</td>
</tr>
<tr>
<td valign="top" align="left">Rot et al. (2020)<xref ref-type="table-fn" rid="table-fn4"><sup>b</sup></xref> (<xref ref-type="bibr" rid="B31">31</xref>)</td>
<td valign="top" align="left">Adult: 17</td>
<td valign="top" align="left">Mean (range): 57 (26&#x2013;80)</td>
<td valign="top" align="left">Congenital hydrocephalus: 6; posthemorrhagic hydrocephalus: 3; obstructive hydrocephalus: 4; tumor-related hydrocephalus: 3; craniosynostosis: 3; cystic malformation: 1; trauma and stress related: 1; IIH: 1</td>
<td valign="top" align="left">Primary shunt surgery (Neurovent-P-tel); postoperative surveillance (Miethke SR)</td>
<td valign="top" align="left">Neurovent-P-tel (first 3 months) and Miethke SR (after 3 months)</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">Overdrainage: 1</td>
</tr>
<tr>
<td valign="top" align="left">Pennacchietti et al. (2020) (<xref ref-type="bibr" rid="B32">32</xref>)</td>
<td valign="top" align="left">Adult and pediatric: 21</td>
<td valign="top" align="left">Median (range): 16.5 (10&#x2013;39.5)</td>
<td valign="top" align="left">Congenital hydrocephalus: 5; posthemorrhagic hydrocephalus: 3; obstructive hydrocephalus: 7; craniosynostosis: 3; cystic malformation: 1; IIH: 1; trauma and stress related: 1</td>
<td valign="top" align="left">Diagnostic evaluation: 6/21 (all Miethke SR); postoperative surveillance: 15/21 (Neurovent-P-tel: 8; Miethke SR: 7)</td>
<td valign="top" align="left">Neurovent-P-tel: 8/21; Miethke SR: 13/21</td>
<td valign="top" align="left">Median (range): 4.2 (4&#x2013;13) months</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">No device revision; explantations due to complications: 3</td>
<td valign="top" align="left">Neurovent-P-tel: 1 infection, 1 seizure; Miethke SR: 1 infection</td>
</tr>
<tr>
<td valign="top" align="left">Pedersen et al. (2020) (<xref ref-type="bibr" rid="B33">33</xref>)</td>
<td valign="top" align="left">Pediatric: 20</td>
<td valign="top" align="left">Median (range): 11 (2&#x2013;18)</td>
<td valign="top" align="left">Hydrocephalus, unspecified: 12; IIH: 7; cystic malformation: 1</td>
<td valign="top" align="left">Diagnostic evaluation: 4/32; postoperative surveillance: 28/32</td>
<td valign="top" align="left">Neurovent-P-tel</td>
<td valign="top" align="left">Median (range): 523 (42&#x2013;2,067) days</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">17 devices explanted (12 replaced): complications: 2; technical defects: 12; parent request: 3</td>
<td valign="top" align="left">Wound infection: 1; skin erosion: 1</td>
</tr>
<tr>
<td valign="top" align="left">M&#x00FC;ller et al. (2019) (<xref ref-type="bibr" rid="B34">34</xref>)</td>
<td valign="top" align="left">Adult: 7</td>
<td valign="top" align="left">Mean (SD): 48.6 (12.2)</td>
<td valign="top" align="left">IIH: 2; congenital hydrocephalus: 2; NPH: 1; hydrocephalus, unspecified: 2</td>
<td valign="top" align="left">Postoperative surveillance</td>
<td valign="top" align="left">Neurovent-P-tel</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
</tr>
<tr>
<td valign="top" align="left">Norager et al. (2019) (<xref ref-type="bibr" rid="B35">35</xref>)</td>
<td valign="top" align="left">Adult and pediatric: 2</td>
<td valign="top" align="left">7, 27</td>
<td valign="top" align="left">Congenital hydrocephalus: 2</td>
<td valign="top" align="left">Postoperative surveillance</td>
<td valign="top" align="left">Neurovent-P-tel and Miethke SR</td>
<td valign="top" align="left">Case 1: each Neurovent-P-tel implanted for months at a time, with repeated reimplantations; case 2: same SR functioning &#x003E;2 years</td>
<td valign="top" align="left">Case 1: 2 years; case 2: 767 days</td>
<td valign="top" align="left">Case 1: 3 reimplantations of Neurovent-P-tel over 2 years due to suspected measurement issues; case 2: Miethke SR was implanted due to multiple failures of Neurovent-P-tel</td>
<td valign="top" align="left">NS</td>
</tr>
<tr>
<td valign="top" align="left">Tschan et al. (2019) (<xref ref-type="bibr" rid="B36">36</xref>)</td>
<td valign="top" align="left">Adult and pediatric: 20</td>
<td valign="top" align="left">Mean (SD): 33.2 (16.3)</td>
<td valign="top" align="left">IIH: 5; obstructive hydrocephalus: 6; cystic malformations: 4; posthemorrhagic hydrocephalus: 1; postinfectious hydrocephalus: 1; congenital hydrocephalus: 2; trauma and stress related: 1; cystic malformations: 2</td>
<td valign="top" align="left">Diagnostic evaluation: 7/20; postoperative surveillance: 13/20</td>
<td valign="top" align="left">Neurovent-P-tel: 20</td>
<td valign="top" align="left">Mean (SD): 278.5&#x202F;(250.1) days</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">None</td>
<td valign="top" align="left">None</td>
</tr>
<tr>
<td valign="top" align="left">Norager et al. (2018) (<xref ref-type="bibr" rid="B37">37</xref>)</td>
<td valign="top" align="left">Adult and pediatric: 119</td>
<td valign="top" align="left">Median (IQR): 30 (17&#x2013;50)</td>
<td valign="top" align="left">Hydrocephalus, unspecified: 42; IIH: 46; NPH: 5; cystic malformation: 1<xref ref-type="table-fn" rid="table-fn9"><sup>e</sup></xref></td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">Neurovent-P-tel: 125</td>
<td valign="top" align="left">Median (95&#x0025; CI): 556 (382&#x2013;605) days</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">6 reimplantations</td>
<td valign="top" align="left">Skin damage (erosion): 5; wound infection: 3; ethylene oxide allergy: 2</td>
</tr>
<tr>
<td valign="top" align="left">Antes et al. (2018) (<xref ref-type="bibr" rid="B38">38</xref>)</td>
<td valign="top" align="left">Adult and pediatric: 25</td>
<td valign="top" align="left">Mean (SD): 53.6 (20.7)</td>
<td valign="top" align="left">NPH: 8; IIH: 7; congenital hydrocephalus: 5; obstructive hydrocephalus: 3; hydrocephalus, unspecified: 2</td>
<td valign="top" align="left">Postoperative surveillance</td>
<td valign="top" align="left">Miethke SR</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">Mean (SD): 213.8&#x202F;(119.4) days</td>
<td valign="top" align="left">No explantation/reimplantation</td>
<td valign="top" align="left">Wound healing disorders: 2; shunt infection: 1</td>
</tr>
<tr>
<td valign="top" align="left">Thompson et al. (2018) (<xref ref-type="bibr" rid="B39">39</xref>)</td>
<td valign="top" align="left">Age group not defined: 60</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">Shunt surgery</td>
<td valign="top" align="left">Miethke SR</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
</tr>
<tr>
<td valign="top" align="left">Ertl et al. (2017) (<xref ref-type="bibr" rid="B41">41</xref>)</td>
<td valign="top" align="left">Adult: 2</td>
<td valign="top" align="left">66, 78</td>
<td valign="top" align="left">NPH: 2</td>
<td valign="top" align="left">Primary shunt surgery</td>
<td valign="top" align="left">Miethke SR</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
</tr>
<tr>
<td valign="top" align="left">Barber et al. (2017) (<xref ref-type="bibr" rid="B42">42</xref>)</td>
<td valign="top" align="left">Pediatric: 4</td>
<td valign="top" align="left">Mean (SD): 9.0 (5.1)</td>
<td valign="top" align="left">Posthemorrhagic hydrocephalus: 1; trauma and stress related: 1; obstructive hydrocephalus: 1; tumor-related hydrocephalus: 1</td>
<td valign="top" align="left">Diagnostic evaluation</td>
<td valign="top" align="left">Neurovent-P-tel</td>
<td valign="top" align="left">Range: 460&#x2013;632 days</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
</tr>
<tr>
<td valign="top" align="left">Antes et al. (2016) (<xref ref-type="bibr" rid="B16">16</xref>)</td>
<td valign="top" align="left">Adult and pediatric: 247</td>
<td valign="top" align="left">Mean (SD): 59.3 (20.7)</td>
<td valign="top" align="left">Postinfectious hydrocephalus: 2; tumor-related hydrocephalus: 4; IIH: 34; NPH: 138; obstructive hydrocephalus: 42; posthemorrhagic hydrocephalus: 2; congenital hydrocephalus: 14; Chiari malformation: 4; trauma and stress related: 6; cystic malformation: 1</td>
<td valign="top" align="left">Diagnostic evaluation: 105; shunt revision or prior to planned ETV: 124<xref ref-type="table-fn" rid="table-fn6"><sup>c</sup></xref></td>
<td valign="top" align="left">Neurovent-P-tel</td>
<td valign="top" align="left">Mean (SD): 46.9&#x202F;&#x00B1;&#x202F;26.0 days</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">All devices were explanted; no shunt revisions</td>
<td valign="top" align="left">Hemiparesis: 1; new-onset seizures: 11; brain abscess: 2; wound infection: 4</td>
</tr>
<tr>
<td valign="top" align="left">Andresen et al. (2016) (<xref ref-type="bibr" rid="B43">43</xref>)</td>
<td valign="top" align="left">Adult and pediatric: 15<xref ref-type="table-fn" rid="table-fn5"><sup>i</sup></xref></td>
<td valign="top" align="left">Mean (range): 32 (8&#x2013;71)</td>
<td valign="top" align="left">Hydrocephalus, unspecified: 9; IIH: 6</td>
<td valign="top" align="left">Diagnostic evaluation or postoperative surveillance</td>
<td valign="top" align="left">Neurovent-P-tel</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
</tr>
<tr>
<td valign="top" align="left">Maeske et al. (2016) (<xref ref-type="bibr" rid="B44">44</xref>)</td>
<td valign="top" align="left">Adult and pediatric: 15</td>
<td valign="top" align="left">Mean (SD): 29.1 (14.6)</td>
<td valign="top" align="left">IIH: 6; hydrocephalus, unspecified: 5; Chiari malformation: 2; obstructive hydrocephalus: 1; congenital hydrocephalus: 1</td>
<td valign="top" align="left">Postoperative surveillance</td>
<td valign="top" align="left">Neurovent-P-tel</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
</tr>
<tr>
<td valign="top" align="left">Andresen et al. (2015) (<xref ref-type="bibr" rid="B47">47</xref>)</td>
<td valign="top" align="left">Adult and pediatric: 27</td>
<td valign="top" align="left">Mean (range): 35.11 (8&#x2013;71)</td>
<td valign="top" align="left">IIH: 7; NPH: 2; hydrocephalus, unspecified: 18</td>
<td valign="top" align="left">Diagnostic evaluation or postoperative surveillance</td>
<td valign="top" align="left">Neurovent-P-tel</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
</tr>
<tr>
<td valign="top" align="left">Farahmand et al. (2015) (<xref ref-type="bibr" rid="B45">45</xref>)</td>
<td valign="top" align="left">Adult: 15</td>
<td valign="top" align="left">Mean (SD): 70.5 (8.9)<xref ref-type="table-fn" rid="table-fn7"><sup>d</sup></xref></td>
<td valign="top" align="left">NPH: 14; obstructive hydrocephalus: 1</td>
<td valign="top" align="left">Primary shunt surgery</td>
<td valign="top" align="left">Neurovent-P-tel</td>
<td valign="top" align="left">All devices explanted within 1 day</td>
<td valign="top" align="left">3 months for every pt</td>
<td valign="top" align="left">All devices explanted within 1 day</td>
<td valign="top" align="left">Shunt infection: 1</td>
</tr>
<tr>
<td valign="top" align="left">Raffalli-Ebezant et al. (2014) (<xref ref-type="bibr" rid="B46">46</xref>)</td>
<td valign="top" align="left">Pediatric: 3</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">Hydrocephalus, unspecified: 2; cystic malformation: 1</td>
<td valign="top" align="left">Postoperative surveillance: 3</td>
<td valign="top" align="left">Neurovent-P-tel</td>
<td valign="top" align="left">Mean: 5 days</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">1 pt required further neurosurgical intervention after pathological ICP detection</td>
<td valign="top" align="left">None</td>
</tr>
<tr>
<td valign="top" align="left">Antes et al. (2014) (<xref ref-type="bibr" rid="B48">48</xref>)</td>
<td valign="top" align="left">Adult and pediatric: 24</td>
<td valign="top" align="left">Mean (SD): 46.9 (18.4)</td>
<td valign="top" align="left">Obstructive hydrocephalus: 24</td>
<td valign="top" align="left">Primary ETV procedure</td>
<td valign="top" align="left">Neurovent-P-tel</td>
<td valign="top" align="left">Mean: 106.1&#x2005;h</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">Proceeding with shunt due to failed ETV in 7 cases</td>
<td valign="top" align="left">Intraventricular bleeding: 2; thalamic contusion: 1</td>
</tr>
<tr>
<td valign="top" align="left">Lilja et al. (2014) (<xref ref-type="bibr" rid="B49">49</xref>)</td>
<td valign="top" align="left">Adult and pediatric: 21</td>
<td valign="top" align="left">Median (range): 28 (2&#x2013;83)</td>
<td valign="top" align="left">Hydrocephalus, unspecified: 11; IIH: 7; NPH: 3</td>
<td valign="top" align="left">Diagnostic evaluation or postoperative surveillance</td>
<td valign="top" align="left">Neurovent-P-tel: 22<xref ref-type="table-fn" rid="table-fn11"><sup>g</sup></xref></td>
<td valign="top" align="left">Median (range): 248 (49&#x2013;666) days</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">29 of 86 recordings led to surgical shunt revision</td>
<td valign="top" align="left">Late wound infection: 2; ethylene oxide allergy: 2</td>
</tr>
<tr>
<td valign="top" align="left">Freimann et al. (2014) (<xref ref-type="bibr" rid="B50">50</xref>)</td>
<td valign="top" align="left">Adult and pediatric: 4</td>
<td valign="top" align="left">Mean (SD): 12.5 (6.0)</td>
<td valign="top" align="left">Tumor-related hydrocephalus: 2; congenital hydrocephalus: 1; obstructive hydrocephalus: 1</td>
<td valign="top" align="left">Primary shunt revision surgery: 4</td>
<td valign="top" align="left">Neurovent-P-tel</td>
<td valign="top" align="left">Mean (SD): 8.0 (5.9) months</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">None</td>
</tr>
<tr>
<td valign="top" align="left">Antes et al. (2014) (<xref ref-type="bibr" rid="B51">51</xref>)</td>
<td valign="top" align="left">Adult and pediatric: 185</td>
<td valign="top" align="left">Mean (SD): 54.9 (23.0)</td>
<td valign="top" align="left">NPH: 68; occlusive hydrocephalus: 27; IIH: 6; hydrocephalus, unspecified: 10; shunt-related disorders: 55<xref ref-type="table-fn" rid="table-fn12"><sup>h</sup></xref></td>
<td valign="top" align="left">Diagnostic evaluation: 111; postoperative surveillance: 74</td>
<td valign="top" align="left">Neurovent-P-tel: 185</td>
<td valign="top" align="left">Mean (SD): 60.7 (58.1) days</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">23 shunt or valve revision surgeries</td>
<td valign="top" align="left">Brain abscess: 1; superficial wound infections: 2; new-onset seizures: 6; temporary hemiparesis: 1</td>
</tr>
<tr>
<td valign="top" align="left">Tschan et al. (2013) (<xref ref-type="bibr" rid="B52">52</xref>)</td>
<td valign="top" align="left">Pediatric: 26</td>
<td valign="top" align="left">Mean (range): 10.5 (1.5&#x2013;18)</td>
<td valign="top" align="left">NS<xref ref-type="table-fn" rid="table-fn8"><sup>j</sup></xref></td>
<td valign="top" align="left">Diagnostic evaluation or postoperative surveillance</td>
<td valign="top" align="left">Neurovent-P-tel</td>
<td valign="top" align="left">Mean (range): 61 (8&#x2013;209) days</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">None</td>
</tr>
<tr>
<td valign="top" align="left">Welschehold et al. (2012) (<xref ref-type="bibr" rid="B54">54</xref>)</td>
<td valign="top" align="left">Adult and pediatric: 10</td>
<td valign="top" align="left">Mean (SD): 21.1 (16.95)</td>
<td valign="top" align="left">Obstructive hydrocephalus: 4; posthemorrhagic hydrocephalus: 2; hydrocephalus, unspecified: 1; IIH: 1; craniosynostosis: 1; shunt-related disorders: 1</td>
<td valign="top" align="left">Postoperative surveillance: 10</td>
<td valign="top" align="left">Neurovent-P-tel</td>
<td valign="top" align="left">Mean (SD): 40.1&#x202F;(51.1) days<xref ref-type="table-fn" rid="table-fn13"><sup>k</sup></xref></td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">Shunt revision or implantation in 3 pts</td>
<td valign="top" align="left">None</td>
</tr>
<tr>
<td valign="top" align="left">Frim and Lathrop (2000) (<xref ref-type="bibr" rid="B56">56</xref>)</td>
<td valign="top" align="left">Adult and pediatric: 10</td>
<td valign="top" align="left">Mean (range): 29.4 (1&#x2013;84)</td>
<td valign="top" align="left">Congenital hydrocephalus: 2; NPH: 2; cystic malformation: 2; IIH: 3; trauma and stress related: 1</td>
<td valign="top" align="left">Primary and revision shunt placement</td>
<td valign="top" align="left">Radionics TeleSensor: 12</td>
<td valign="top" align="left">12 months</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">2 shunt revisions due to infection</td>
<td valign="top" align="left">NS</td>
</tr>
<tr>
<td valign="top" align="left">Frim and Goumnervoa (2000) (<xref ref-type="bibr" rid="B57">57</xref>)</td>
<td valign="top" align="left">Adult and pediatric: 22</td>
<td valign="top" align="left">Median (range): 27.5 (7&#x2013;71)</td>
<td valign="top" align="left">Congenital hydrocephalus: 3; NPH: 2; posthemorrhagic hydrocephalus: 17</td>
<td valign="top" align="left">Initial shunt placement: 22; revision shunt surgery: 3</td>
<td valign="top" align="left">Radionics TeleSensor: 25</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">3 shunt systems revised after initial pressures obtained</td>
<td valign="top" align="left">NS</td>
</tr>
<tr>
<td valign="top" align="left">Richard et al. (1999) (<xref ref-type="bibr" rid="B58">58</xref>)</td>
<td valign="top" align="left">Adult and pediatric: 7</td>
<td valign="top" align="left">Mean (SD): 40.29 (19.18)</td>
<td valign="top" align="left">NPH: 4; shunt-related disorders: 3</td>
<td valign="top" align="left">Primary shunt placement: 7; revision shunt placement: 1</td>
<td valign="top" align="left">Telemeasurement GmbH integrated ICP-sensor (custom made): 8</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">14&#x2013;17 months</td>
<td valign="top" align="left">1 shunt revision due to traumatic valve deformation</td>
<td valign="top" align="left">NS</td>
</tr>
<tr>
<td valign="top" align="left">Munshi et al. (1998) (<xref ref-type="bibr" rid="B60">60</xref>)</td>
<td valign="top" align="left">Adult and pediatric: 4</td>
<td valign="top" align="left">Range: 12&#x2013;71</td>
<td valign="top" align="left">Posthemorrhagic hydrocephalus: 2; hydrocephalus, unspecified: 1; congenital hydrocephalus: 1</td>
<td valign="top" align="left">Shunt revision: 4</td>
<td valign="top" align="left">Radionics TeleSensor</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
</tr>
<tr>
<td valign="top" align="left">Miyake et al. (1997) (<xref ref-type="bibr" rid="B71">71</xref>)</td>
<td valign="top" align="left">Adult and pediatric: 94</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">Obstructive hydrocephalus: 5; tumor-related hydrocephalus: 16; NPH: 15; posthemorrhagic hydrocephalus: 45; hydrocephalus, unspecified: 13</td>
<td valign="top" align="left">Primary shunt surgery: 94</td>
<td valign="top" align="left">Osaka telesensor</td>
<td valign="top" align="left">Mean (range): 14.5 (1&#x2013;44) months</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
</tr>
<tr>
<td valign="top" align="left">Frim and Goumnervoa (1997) (<xref ref-type="bibr" rid="B61">61</xref>)</td>
<td valign="top" align="left">Adult: 1</td>
<td valign="top" align="left">30</td>
<td valign="top" align="left">Obstructive hydrocephalus: 1</td>
<td valign="top" align="left">Primary ETV procedure: 1</td>
<td valign="top" align="left">Radionics TeleSensor: 1</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">None</td>
<td valign="top" align="left">NS</td>
</tr>
<tr>
<td valign="top" align="left">Longatti and Carteri (1994) (<xref ref-type="bibr" rid="B70">70</xref>)</td>
<td valign="top" align="left">Adult and pediatric: 21</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">Obstructive hydrocephalus: 4; hydrocephalus, unspecified: 17</td>
<td valign="top" align="left">Postoperative surveillance: 21</td>
<td valign="top" align="left">Telemetric ICP detector</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">None</td>
<td valign="top" align="left">NS</td>
</tr>
<tr>
<td valign="top" align="left">Kamiryo et al. (1991) (<xref ref-type="bibr" rid="B63">63</xref>)</td>
<td valign="top" align="left">Pediatric: 1</td>
<td valign="top" align="left">8</td>
<td valign="top" align="left">Shunt-related disorders: 1</td>
<td valign="top" align="left">Shunt revision surgery: 1</td>
<td valign="top" align="left">Nagano Keiki NS20 telemetric ICP sensor</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">None</td>
<td valign="top" align="left">NS</td>
</tr>
<tr>
<td valign="top" align="left">Chapman et al. (1990) (<xref ref-type="bibr" rid="B65">65</xref>)</td>
<td valign="top" align="left">Adult and pediatric: 22</td>
<td valign="top" align="left">Mean (SD): 25.41 (18.93)</td>
<td valign="top" align="left">Obstructive hydrocephalus: 5; IIH: 2; hydrocephalus, unspecified: 15</td>
<td valign="top" align="left">Primary and revision shunt placement</td>
<td valign="top" align="left">Radionics TeleSensor</td>
<td valign="top" align="left">NS (up to 4 years in some pts)</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">None</td>
<td valign="top" align="left">NS</td>
</tr>
<tr>
<td valign="top" align="left">G&#x00FC;&#x00E7;er et al. (1988) (<xref ref-type="bibr" rid="B66">66</xref>)</td>
<td valign="top" align="left">Adult: 127</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">Hydrocephalus, unspecified: 94; IIH: 21; obstructive hydrocephalus: 12</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">Epidural passive radiotelemetric ICP sensor</td>
<td valign="top" align="left">Mean (SD): 6.8 (0.44) years</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">Asymptomatic perisensor epidural hematomas: 2</td>
</tr>
<tr>
<td valign="top" align="left">Maas and de Jong (1986) (<xref ref-type="bibr" rid="B67">67</xref>)</td>
<td valign="top" align="left">Pediatric: 22</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">Trauma and stress related: 13; hydrocephalus, unspecified: 6; posthemorrhagic hydrocephalus: 2; tumor-related hydrocephalus: 1</td>
<td valign="top" align="left">Diagnostic evaluation: 22</td>
<td valign="top" align="left">Rotterdam Teletransducer</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">1 device removal</td>
<td valign="top" align="left">Superficial wound infection: 1</td>
</tr>
<tr>
<td valign="top" align="left">Chapman et al. (1984) (<xref ref-type="bibr" rid="B69">69</xref>)</td>
<td valign="top" align="left">Adult and pediatric: 8</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">Obstructive hydrocephalus: 8</td>
<td valign="top" align="left">Tumor resection: 8</td>
<td valign="top" align="left">Custom telemetric monitoring system</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">NS</td>
<td valign="top" align="left">None</td>
</tr>
<tr>
<td valign="top" align="left">Nulsen et al. (1980) (<xref ref-type="bibr" rid="B68">68</xref>)</td>
<td valign="top" align="left">Pediatric: 3</td>
<td valign="top" align="left">Mean (SD): 8.33 (3.79)</td>
<td valign="top" align="left">Posthemorrhagic hydrocephalus: 1; tumor-related hydrocephalus: 1; obstructive hydrocephalus: 1</td>
<td valign="top" align="left">Shunt revision or tumor resection</td>
<td valign="top" align="left">Custom telemetric monitoring system</td>
<td valign="top" align="left">Mean (SD): 27.3&#x202F;(11.9) days<xref ref-type="table-fn" rid="table-fn13"><sup>k</sup></xref></td>
<td valign="top" align="left">39 days</td>
<td valign="top" align="left">1 pt required shunt revision after telemetry showed high ICP</td>
<td valign="top" align="left">NS</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="table-fn2"><p>The etiologies reported in the included studies were classified under the following categories for clarity: obstructive hydrocephalus (including obstructive hydrocephalus, aqueductal stenosis, occlusive hydrocephalus, pineal astrocytoma, tumor, brain tumor, tumor-related hydrocephalus, noncommunicating hydrocephalus, and postaqueductal stenosis); NPH (NPH, idiopathic NPH, secondary NPH); IIH (benign intracranial hypertension, IIH, pseudotumor cerebri); congenital hydrocephalus (congenital hydrocephalus, infantile hydrocephalus, myelomeningocele, meningomyelocele, complex congenital malformation, megalencephaly-capillary malformation syndrome, occipital encephalocele-related hydrocephalus, congenital/complex malformation, complex cerebral malformation, spina bifida); posthemorrhagic hydrocephalus (posthemorrhagic hydrocephalus, intracerebral hematoma, subarachnoid hemorrhage, cerebral hemorrhage); posttumor hydrocephalus (posttumor hydrocephalus, intracerebral gliomas, malresorptive hydrocephalus related to recurrent craniopharyngioma and cerebellar astrocytoma, tumor surgery); Chiari malformation (Chiari malformation, Arnold-Chiari syndrome); craniosynostosis (craniosynostosis, Pfeiffer&#x0027;s syndrome, Crouzon syndrome); postinfectious hydrocephalus (hydrocephalus in infectious diseases, postinfectious hydrocephalus, cerebral infection); shunt-related disorders (shunt malfunction, chronic underdrainage after shunt revision, intermittent shunt dysfunction, slit ventricle syndrome, CSF leak, pseudomeningocele); trauma and stress-related (severe head injury, traumatic brain injury, posttraumatic hydrocephalus, hypoxic brain injury, intracranial hypertension after thrombosis or hemorrhage, brain edema); cystic malformations (Blake&#x0027;s pouch cyst, infratentorial cyst, Dandy Walker variant or syndrome, arachnoid cyst, postarachnoid cyst fenestration hydrocephalus, suprasellar arachnoid cyst, type III arachnoid cyst). CI, confidence interval; CSF, cerebrospinal fluid; ICP, intracranial pressure; IIH, idiopathic intracranial hypertension; IQR, interquartile range; NA, not applicable; NPH, normal pressure hydrocephalus; NS, not specified; pt, patient; SR, sensor reservoir.</p></fn>
<fn id="table-fn3"><label><sup>a</sup></label>
<p>The included children represent a wide section of hydrocephalus diagnoses. Some children have more than 1 diagnosis, and thus the total number of diagnoses does not equal the number of children participating in the study. In addition, the number of devices exceeds the number of patients, indicating that multiple devices were used for some individuals.</p></fn>
<fn id="table-fn4"><label><sup>b</sup></label>
<p>All patients initially recieved Neurovent-P-tel implants; however, because its approved implantation period is limited to 90 days, the device had to be replaced after this time point.</p></fn>
<fn id="table-fn6"><label><sup>c</sup></label>
<p>The first group included patients with suspected CSF disorders, and the second group consisted of those with confirmed CSF disorders.</p></fn>
<fn id="table-fn7"><label><sup>d</sup></label>
<p>Five patients were excluded from this study, 1 of whom had a fulminant shunt infection. The remaining cohort was included in the final analysis.</p></fn>
<fn id="table-fn9"><label><sup>e</sup></label>
<p>Twenty-five patients were included in the study solely for research purposes.</p></fn>
<fn id="table-fn10"><label><sup>f</sup></label>
<p>Although the study initially included 74 patients, only 48 propensity-matched pairs were reported. Additionally, 8 patients were categorized under &#x201C;other,&#x201D; which included conditions such as CSF leak, pseudomeningocele, subarachnoid hemorrhage, and aqueductal stenosis. However, as the exact distribution of these diagnoses was not specified, only 40 patients were included in the final analysis.</p></fn>
<fn id="table-fn11"><label><sup>g</sup></label>
<p>One patient had 2 sensors implanted due to infection after receipt of the first implant.</p></fn>
<fn id="table-fn12"><label><sup>h</sup></label>
<p>Nineteen patients underwent implantation of telemetric probes for post-operative monitoring (shunt, ETV, etc.).</p></fn>
<fn id="table-fn5"><p><sup>i</sup>Four patients with brain tumors were used as a reference group because they did not have any underlying CSF disorder. Therefore, this group was excluded from the table for the remaining data analyses.</p></fn>
<fn id="table-fn8"><p><sup>j</sup>Main indications for ICP measurements were suspected hydrocephalus, exclusion of shunt dysfunction, monitoring after shunt ligature, and patency control after neuroendoscopy.</p></fn>
<fn id="table-fn13"><p><sup>k</sup>In descriptive statistics, values indicated as &#x201C;greater than&#x201D; (e.g., &#x201C;&#x003E;180&#x201D;) were approximated by the threshold value itself (e.g., 180).</p></fn>
</table-wrap-foot>
</table-wrap>
<fig id="F3" position="float"><label>Figure 3</label>
<caption><p>Summary of cerebrospinal fluid (CSF) disorder types, device placement timing, and complication rates as reported across the reviewed studies. <bold>(A)</bold> Types of CSF disorders. <bold>(B)</bold> Timing of device insertion. In cases in which the number of devices was not specified but only a single &#x201C;timing of device placement&#x201D; was mentioned, 100&#x0025; of the corresponding bar was allocated to that indication. Conversely, when multiple indications were reported without exact counts, the bar was proportionally divided equally among them. Studies with such assumptions are denoted with a hash symbol (&#x0023;). <bold>(C)</bold> Complications. Studies lacking complication data, either due to the absence of reported events or omission of relevant information, were excluded from this analysis. The bar graph represents proportional distributions derived exclusively from the reported numbers. Used with permission from Barrow Neurological Institute, Phoenix, Arizona.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fped-13-1632216-g003.tif"><alt-text content-type="machine-generated">Three bar charts labeled A, B, and C summarize data from the reviewed studies. Chart A shows the distribution of cerebrospinal fluid (CSF) disorder types. Chart B illustrates the timing of device insertion. When only one timing indication was reported without specifying the number of devices, the entire bar (100%) was assigned to that indication. When multiple indications were reported without exact counts, the bar was proportionally divided equally. Chart C displays complication rates. Studies without complication data, either due to no reported events or omission of relevant details, were excluded. Each bar chart represents proportional distributions based solely on the reported numbers.</alt-text>
</graphic>
</fig>
<p>Among the reported timings for telemetric device insertion, the most common was during diagnostic evaluation (<italic>n</italic>&#x2009;&#x003D;&#x2009;376), followed by during postoperative surveillance (<italic>n</italic>&#x2009;&#x003D;&#x2009;329), at the time of primary shunt or ETV surgery (<italic>n</italic>&#x2009;&#x003D;&#x2009;264), and at the time of shunt or ETV revision surgery (<italic>n</italic>&#x2009;&#x003D;&#x2009;186). Insertion during tumor resection was reported in 10 cases, and the timing was not specified in 246 cases (<xref ref-type="fig" rid="F3">Figure&#x00A0;3</xref>).</p>
<p>The most frequently reported complications were neurological events (<italic>n</italic>&#x2009;&#x003D;&#x2009;21) and skin-related issues, including irritation and erosion (<italic>n</italic>&#x2009;&#x003D;&#x2009;22). These were followed by shunt-related complications (<italic>n</italic>&#x2009;&#x003D;&#x2009;11), wound infections or dehiscence (<italic>n</italic>&#x2009;&#x003D;&#x2009;10), and discomfort or cosmetic concerns (<italic>n</italic>&#x2009;&#x003D;&#x2009;9). Pain was reported in 7 cases, and nonshunt, non-wound-related infections were documented in 5 cases. Hemorrhage or hematoma occurred in 6 cases (<xref ref-type="fig" rid="F3">Figure&#x00A0;3</xref> and <xref ref-type="table" rid="T2">Table&#x00A0;2</xref>).</p>
<p>The functional duration of telemetric devices was reported, along with statistical details, in 14 studies. Based on these, the pooled average functional duration was calculated to be 529.41&#x202F;(836.94) days (<xref ref-type="table" rid="T2">Table&#x00A0;2</xref>). However, because the studies did not consistently associate specific device types with their respective durations, direct comparison of functional lifespan between different telemetric systems was not feasible.</p>
</sec>
<sec id="s4"><label>4</label><title>Discussion</title>
<p>ICP can increase due to various neurosurgical pathologies, including hemorrhages, tumors, infections, and both primary and secondary hydrocephalus (<xref ref-type="bibr" rid="B72">72</xref>&#x2013;<xref ref-type="bibr" rid="B78">78</xref>). Therefore, continuous ICP monitoring plays a critical role in guiding timely intervention, especially in hydrocephalus management (<xref ref-type="bibr" rid="B54">54</xref>, <xref ref-type="bibr" rid="B79">79</xref>). Hydrocephalus treatment primarily focuses on correcting underlying CSF circulation disturbances through surgical diversion methods such as cerebral shunts and ETV. However, surgical intervention alone is not always sufficient; effective long-term management is also essential. This ongoing care relies on ICP monitoring to guide diagnosis and treatment, particularly in complex cases involving shunt systems, to optimize patient outcomes (<xref ref-type="bibr" rid="B16">16</xref>, <xref ref-type="bibr" rid="B25">25</xref>, <xref ref-type="bibr" rid="B37">37</xref>, <xref ref-type="bibr" rid="B48">48</xref>, <xref ref-type="bibr" rid="B49">49</xref>). Conditions such as NPH, congenital hydrocephalus, idiopathic intracranial hypertension, postcraniotomy communicating hydrocephalus, and posthemorrhagic hydrocephalus often present with complex and fluctuating symptoms, requiring precise and continuous ICP measurement (<xref ref-type="bibr" rid="B27">27</xref>, <xref ref-type="bibr" rid="B30">30</xref>, <xref ref-type="bibr" rid="B32">32</xref>).</p>
<p>Although technological advancements have improved CSF drainage techniques, determining optimal valve adjustments remains largely dependent on clinical and radiological findings. These methods may not always be sufficient to accurately detect abnormal ICP changes (<xref ref-type="bibr" rid="B9">9</xref>). Telemetric sensors have emerged as a potential solution, offering continuous, noninvasive ICP monitoring for postoperative surveillance, particularly for shunt-treated patients (<xref ref-type="bibr" rid="B16">16</xref>, <xref ref-type="bibr" rid="B38">38</xref>). Since their initial development, 8 different models of telemetric ICP monitoring devices have been produced and clinically tested to date.</p>
<sec id="s4a"><label>4.1</label><title>Clinically tested telemetric devices and their operating principles</title>
<sec id="s4a1"><label>4.1.1</label><title>Radionics TeleSensor (1978)</title>
<p>First described in 1972 and later produced by Radionics, Inc. (Burlington, MA, USA), this sensor uses an inductor and capacitor to form a resonant circuit with passive readout (<xref ref-type="bibr" rid="B80">80</xref>). The inductor consists of a coil of wire wrapped around a ferrite core mounted on a movable diaphragm. CSF pressure pushes the diaphragm, moving the ferrite core and thereby changing the resonant frequency. As shown in <xref ref-type="fig" rid="F4">Figure&#x00A0;4</xref>, the resonant frequency is measured by an external antenna using the grid dip method: the external reader applies a frequency sweep to find the resonance peak.</p>
<fig id="F4" position="float"><label>Figure 4</label>
<caption><p>Diagram of Radionics TeleSensor implant and readout system, including pressure source used to counterbalance the intracranial pressure at the sensor. The diaphragm is built with a stop, which prevents movement of the inductor core past a fixed position. The diaphragm can expand freely but cannot compress to less than its rest position (the position at zero difference between intracranial and subgaleal pressure). The stop serves as a reference point, which is essential for the calibration and readout of the sensor (<xref ref-type="bibr" rid="B107">107</xref>). Figure is in the public domain. Retrieved from <ext-link ext-link-type="uri" xlink:href="https://patents.google.com/patent/US4653508A/en">https://patents.google.com/patent/US4653508A/en</ext-link>.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fped-13-1632216-g004.tif"><alt-text content-type="machine-generated">Schematic diagram of the Radionics TeleSensor implant and readout system. The illustration includes the pressure source used to counterbalance intracranial pressure at the sensor. The diaphragm incorporates a fixed stop that prevents the inductor core from moving beyond a set position. While the diaphragm can expand freely, it cannot compress below its resting state, defined as the position at zero difference between intracranial and subgaleal pressure. This stop functions as a calibration reference point, which is essential for accurate sensor readout.</alt-text>
</graphic>
</fig>
<p>A pressurized air cuff is required for measuring ICP using a pressure-balancing method. For each reading, the sensor is first calibrated by manually pushing the diaphragm against its internal stop and adjusting the readout meter to the calibration line. This line marks the resonant frequency with the diaphragm in its resting position. When the manual pressure is released, internal pressure deforms the diaphragm, which shifts the resonant frequency. To measure ICP, the air cuff is inflated against the scalp, applying increasing pressure until the resonant frequency reaches the calibration mark. At this point, the internal and external pressures are balanced, so the air cuff pressure equals the ICP.</p>
<p>Clinical tests in patients with hydrocephalus showed the utility of this device, with sensors implanted for 6 months experiencing no drift and no loss of sensitivity (<xref ref-type="bibr" rid="B80">80</xref>). The absence of drift can be attributed to the recalibration of the sensor during each use. The accuracy is within 10&#x2013;15&#x2005;mm H<sub>2</sub>O, although this is only when the scalp is not edematous; edema introduces an unknown offset in the pressure reading. The sensor proved useful for managing obstructive hydrocephalus after tumor treatment (<xref ref-type="bibr" rid="B69">69</xref>). Cardiac pulsation in the ICP waveform indicated the patency of the ventricular catheter: when the inlet was occluded, the cardiac waveform was dampened.</p>
<p>A vacuum source is required for reading negative pressure (<xref ref-type="bibr" rid="B65">65</xref>). One study measured the ICP vs. posture curves with different valves (<xref ref-type="bibr" rid="B61">61</xref>). Flow-limited and antisiphon valves showed ICP vs. posture curves similar to those for nonhydrocephalic patients. In patients without shunt placement, the natural antisiphon behavior is mediated by neck veins collapsing when upright, acting as flow-limiting &#x201C;Starling resistors.&#x201D;</p>
<p>The sensor has been tested with adjustable valves, showing that ICP depends not only on valve settings but also on the absorptive site (peritoneum, atrium, or pleura), other shunt components (e.g., antisiphon device), and posture (supine vs. head elevated) (<xref ref-type="bibr" rid="B56">56</xref>). Ventriculopleural shunts yielded lower ICP because of negative pleural pressure (<xref ref-type="bibr" rid="B60">60</xref>).</p>
<p>This telesensor can monitor ICP during recovery from an ETV for noncommunicating hydrocephalus (<xref ref-type="bibr" rid="B61">61</xref>). Flatter ICP vs. posture curves after the ETV showed the recovery of brain compliance. Of note, the same investigator performed all the measurements, which was necessary to address the interoperator variability inherent in the pressure balance method (<xref ref-type="bibr" rid="B58">58</xref>).</p>
<p>Advantages of this system include that it uses an entirely passive implant with no battery and has a fast dynamic response that shows cardiac pulses. Disadvantages include a cumbersome pressure balance method requiring an external pressure cuff and consistent operator (<xref ref-type="bibr" rid="B58">58</xref>) and the need for a vacuum source to measure negative pressure (<xref ref-type="bibr" rid="B65">65</xref>).</p>
</sec>
<sec id="s4a2"><label>4.1.2</label><title>Case Western Reserve University sensor (1980)</title>
<p>Developed by engineers and neurosurgeons at Case Western Reserve University (CWRU) (Cleveland, OH, USA), this design includes several features common to more modern sensors. Unlike the Radionics sensor, which measures ICP relative to an externally applied pressure, the CWRU device uses a sealed case to hold an internal vacuum reference, thereby measuring the absolute pressure. The pressure signal from the silicon piezoresistor is amplified by onboard active electronics (e.g., transistors) and sent to the external reader by an onboard transmitter. Unlike most other designs, the CWRU device is battery-powered.</p>
<p>Clinical tests demonstrated the usefulness of the CWRU device for managing hydrocephalus over time (<xref ref-type="bibr" rid="B68">68</xref>). Initial tests uncovered issues addressed in the second-generation design: (1) device performance was variable, (2) gold foil isolating the sensor was easily damaged, (3) packaging degraded after several months, and (4) the individual circuit components were challenging to assemble reliably (<xref ref-type="bibr" rid="B81">81</xref>, <xref ref-type="bibr" rid="B82">82</xref>).</p>
<p>Packaging failures arose from moisture saturating the encapsulant, which can cause electrical leakage between wires and deformation of the pressure transducer. This issue was resolved using a laser-welded titanium case. Consistency was improved by simplifying the circuit, and battery life was enhanced by using a radiofrequency-controlled power switch to activate the system when needed (<xref ref-type="bibr" rid="B81">81</xref>, <xref ref-type="bibr" rid="B82">82</xref>). A silicon piezoresistor was used as the pressure-sensing element; although it was later proposed that a capacitive pressure sensor be used instead (<xref ref-type="bibr" rid="B83">83</xref>). A diagram of the system architecture, including details of the glass-mounted silicon pressure sensor, is shown in <xref ref-type="fig" rid="F5">Figure&#x00A0;5</xref>. Notably, the CWRU sensor was added to the shunt with a 3-way &#x201C;T&#x201D; connection, with the sensor as a blind end without an outlet.</p>
<fig id="F5" position="float"><label>Figure 5</label>
<caption><p>A system architecture diagram and a schematic of the entire device illustrating the Case Western Reserve University (CWRU) telemetry system (<xref ref-type="bibr" rid="B108">108</xref>). <bold>(A)</bold> Block diagram of the CWRU telemetry system. The pressure sensor resistance reading is amplified and temperature-compensated, then the data are transmitted as a radiofrequency signal to the external receiver. The external receiver sends an on/off signal to activate the sensor. <bold>(B)</bold> Illustration of the CWRU sensor components. Left: Full case, showing housing for the readout circuitry and the circular slot for the pressure sensor. The case (29&#x2005;mm&#x2009;&#x00D7;&#x2009;20&#x2005;mm&#x2009;&#x00D7;&#x2009;7&#x2005;mm) is hermetically sealed, and the vacuum inside is the absolute reference pressure for the sensor. Middle: A closer view of the pressure sensor, with the Pyrex glass tube sealed to the titanium adapter connecting to the ventricular catheter. Right: A closer view of the silicon piezoresistive pressure-sensing diaphragm fused over a small opening in the glass tube. Figure is in the public domain. Retrieved from <ext-link ext-link-type="uri" xlink:href="https://patents.google.com/patent/US4519401A/en">https://patents.google.com/patent/US4519401A/en</ext-link>.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fped-13-1632216-g005.tif"><alt-text content-type="machine-generated">System architecture and schematic of the Case Western Reserve University (CWRU) telemetry system. (A) Block diagram showing the pressure sensor resistance reading, which is amplified, temperature-compensated, and transmitted as a radiofrequency signal to an external receiver. The receiver provides an on/off control signal to activate the sensor. (B) Illustration of the sensor components. Left: The full device case, housing the readout circuitry and a circular slot for the pressure sensor; the hermetically sealed case (29 x 20 x 7 mm) contains a vacuum that serves as the absolute reference pressure. Middle: Enlarged view of the pressure sensor, consisting of a Pyrex glass tube sealed to a titanium adapter connected to the ventricular catheter. Right: Enlarged view of the silicon piezoresistive diaphragm fused over a small opening in the glass tube.</alt-text>
</graphic>
</fig>
</sec>
<sec id="s4a3"><label>4.1.3</label><title>Osaka telesensor (1981)</title>
<p>The Osaka telesensor (Nagano Keiki Seisakusyo Co Ltd, Tokyo, Japan) was described in 1981 (<xref ref-type="bibr" rid="B63">63</xref>, <xref ref-type="bibr" rid="B84">84</xref>). It is an entirely passive device with no batteries, transistors, or other active electronics (<xref ref-type="fig" rid="F6">Figure&#x00A0;6</xref>). Like the Radionics design, pressure is sensed by the movement of a ferrite coil within an inductor coil. This inductor forms part of a resonant circuit. Unlike the Radionics device, the Osaka telesensor has a vacuum-sealed case with an internal reference. The handheld reader unit includes a barometer to subtract this ambient pressure from the signal. The sensor is coupled to an external antenna that detects resonance using the grid dip method for readout. Once the resonant frequency is identified, the reader converts this into absolute pressure based on earlier benchtop calibration (<xref ref-type="bibr" rid="B84">84</xref>).</p>
<fig id="F6" position="float"><label>Figure 6</label>
<caption><p>The Osaka telesensor (<xref ref-type="bibr" rid="B109">109</xref>). <bold>(A)</bold> A cross-sectional schematic of the Osaka telesensor. The inlet receives cerebrospinal fluid (CSF) from the ventricular catheter. The fluid pressure pushes against the spring to expand the bellows, with the ferrite core attached to the free end. The relative position of the ferrite core inside the coil determines the inductance. This pressure-varying inductance and the fixed capacitance set the resonant frequency. The coil also serves as the antenna for coupling to the external reader device. <bold>(B)</bold> A diagram of the sensor as implanted with a ventricular catheter and CSF reservoir, with the readout coil placed against the scalp for measurement. Figure is in the public domain. Retrieved from <ext-link ext-link-type="uri" xlink:href="https://patents.google.com/patent/US4354506A/en">https://patents.google.com/patent/US4354506A/en</ext-link>.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fped-13-1632216-g006.tif"><alt-text content-type="machine-generated">The Osaka telesensor. (A) Cross-sectional schematic showing cerebrospinal fluid (CSF) entering from the ventricular catheter. CSF pressure expands the bellows against a spring, moving a ferrite core within the coil. The core's position determines the inductance, which together with a fixed capacitance sets the resonant frequency. The coil also functions as the antenna for coupling with the external reader. (B) Illustration of the implanted sensor connected to a ventricular catheter and CSF reservoir, with the external readout coil positioned on the scalp for measurement.</alt-text>
</graphic>
</fig>
<p>In clinical testing including patients with hydrocephalus, the Osaka telesensor proved helpful for postoperative care (e.g., diagnosing shunt failure and adjusting valves). The pulse waveform and the ICP response to reservoir pumping provided supplementary information: pulse waves are absent in cases of ventricular catheter occlusion or slit ventricle syndrome (<xref ref-type="bibr" rid="B71">71</xref>). The ICP response to postural changes offered insights into cerebral compliance. The Osaka telesensor exhibited significant zero drift over time, as measured by puncturing the shunt reservoir (<xref ref-type="bibr" rid="B71">71</xref>).</p>
</sec>
<sec id="s4a4"><label>4.1.4</label><title>Rotterdam Teletransducer (1984)</title>
<p>The RTT (Erasmus University, Rotterdam, Netherlands) uses a passive design similar to the Radionics and Osaka sensors but with a pressure sensor based on changing capacitance rather than changing inductance. The handheld interrogation system is similar to the Osaka, using an external coil to sense the implant&#x0027;s resonant frequency and an onboard barometer to convert from absolute pressure to ICP.</p>
<p>The RTT is recognized as a noninvasive fontanelle pressure sensor for infants, but it has also been tested as an epidural sensor (<xref ref-type="bibr" rid="B59">59</xref>, <xref ref-type="bibr" rid="B62">62</xref>, <xref ref-type="bibr" rid="B85">85</xref>). The RTT is a passive device using an inductor-capacitor resonant circuit. The sensing element is the capacitor, which is made of a pressure-deformable titanium diaphragm positioned parallel to a silver plate at a 50-&#x00B5;m distance. The interior of the sensor must remain vacuum-sealed to maintain the zero reference pressure. Titanium was selected for its inertness and strong bonding to the ceramic housing. The ceramic encapsulation with glass or metal brazing joints facilitates radiofrequency transmission and minimizes moisture and gas penetration. Earlier prototypes with epoxy resin encapsulation exhibited tolerable drift for up to 2 months of use only (<xref ref-type="bibr" rid="B67">67</xref>).</p>
<p>The cylindrical assembly was designed to fit into a standard burr hole craniotomy, with a diameter of 10&#x2005;mm and a height of 7&#x2005;mm. Mounting hardware secures the RTT, with a large screw attaching the steel clip to the skull and a small calibration screw used for fine adjustment of the depth. The depth must be carefully adjusted for accurate pressure readings. The transducer was placed by eye in early clinical tests, resulting in errors. A pressure-depth curve was used in subsequent tests to set the transducer position (<xref ref-type="fig" rid="F7">Figure&#x00A0;7</xref>). The curve is created by measuring the apparent pressure as the transducer position is swept over a range of depths. This calibration method could be helpful for any skull-mounted epidural pressure sensor.</p>
<fig id="F7" position="float"><label>Figure 7</label>
<caption><p>Pressure-depth curve diagrams used during Rotterdam Teletransducer placement. <bold>(A)</bold> Diagram of the pressure-depth curve used during Rotterdam Teletransducer placement to verify correct insertion depth for valid pressure sensing. This diagram is based on data from fontanelle pressure measurements, but the procedure for epidural sensing is similar. A calibration screw is used to advance the transducer into closer contact with the dura while recording the pressure reading. The starting position (d&#x2009;&#x003D;&#x2009;0&#x2005;mm) only lightly touched the fontanelle and showed near zero pressure. As the depth was increased from 0 up to 3&#x2005;mm, the pressure first increased, then plateaued, then increased sharply again. The plateau region, where the pressure is constant vs. depth, corresponds to the appropriate contact of the transducer on the fontanelle. The sharp increase after the plateau shows overinsertion when the sensor begins to deform the fontanelle or dura. Note that, in real data, the cardiac and other pressure waves are superimposed on the pressure-depth curve (<xref ref-type="bibr" rid="B67">67</xref>). <bold>(B)</bold> Diagram of the pressure-depth principle. When the transducer is inserted too shallowly, the sensor does not experience the full pressure from the epidural surface because some of the pressure is supported by the skull instead. When inserted correctly, the pressure is uniformly distributed across the skull and the sensor. When inserted too deeply, the sensor begins pushing the dura away from the skull, and therefore, the sensor experiences pressure from an area wider than the sensor face itself. Used with permission from Barrow Neurological Institute, Phoenix, Arizona.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fped-13-1632216-g007.tif"><alt-text content-type="machine-generated">Pressure-depth curve diagrams used during Rotterdam Teletransducer placement. (A) Diagram showing the pressure -depth curve, adapted from fontanelle data but applicable to epidural use. As the transducer advances, the curve shows an initial rise, a plateau indicating proper contact, and a sharp rise indicating overinsertion. A calibration screw adjusts depth while pressure is recorded. (B) Schematic of the pressure -depth principle. Shallow insertion yields incomplete pressure transfer, correct insertion provides uniform contact, and deep insertion causes deformation of the dura, resulting in falsely elevated readings.</alt-text>
</graphic>
</fig>
</sec>
<sec id="s4a5"><label>4.1.5</label><title>Johns Hopkins sensor (1988)</title>
<p>Developed by Johns Hopkins University (Baltimore, MD, USA), this sensor shares many design elements with the RTT. It is a passive device with a pressure-sensitive capacitor and a coil antenna, together forming a resonant circuit with a frequency near 50&#x2005;MHz for readout by an external coil (<xref ref-type="bibr" rid="B66">66</xref>). The sensing capacitor has 2 plates, one fixed in place and the other mounted on expandable bellows. The polycarbonate outer enclosure is filled with silicone fluid, which transmits pressure from the outer diaphragm to compress the bellow. Unlike other sensors designed for direct CSF contact, the Johns Hopkins sensor enclosure is designed for epidural placement through a burr hole craniotomy, with the outer diaphragm placed against the dural surface.</p>
<p>Across an average clinical test duration of 6 years, the sensor showed a significant drift of up to 1&#x2005;mm H<sub>2</sub>O per day (<xref ref-type="bibr" rid="B66">66</xref>). Drift was measured by comparing the sensor data with lumbar puncture readings. Several mechanisms caused drift: (1) The plastic enclosure is gas permeable, and the silicone fluid has a high affinity for absorbing gas, thereby creating internal pressure. Some explanted devices were visibly bulging. (2) The nickel bellows of the capacitive sensor had some porosity, which was observable in a helium leak test, and this caused nitrogen gas loss over time. (3) Explanted sensors had fatigue cracks in the plastic and discoloration of internal parts, showing corrosion by fluid ingress.</p>
</sec>
<sec id="s4a6"><label>4.1.6</label><title>ICP-Telesensor (1999)</title>
<p>The ICP-Telesensor was built in collaboration between Heinrich-Heine University (D&#x00FC;sseldorf, Germany) and Telemeasurement GmbH (W&#x00FC;rselen, Germany) (<xref ref-type="bibr" rid="B58">58</xref>). Like the Johns Hopkins sensor discussed above, the ICP-Telesensor involves a passive design that uses a pressure-deformable capacitor. The capacitor shifts the implant&#x0027;s resonant frequency, which is interrogated by an external readout coil.</p>
<p>A 0.1-mm titanium membrane serves as the deforming capacitor membrane. The sensor is a flow-through device and is placed between the ventricular catheter and the valve. As a sealed absolute pressure sensor, the reader must compensate for barometric pressure to find the ICP. The sensor was safe and useful for hydrocephalus management in preliminary clinical testing (<xref ref-type="bibr" rid="B58">58</xref>). The capability to measure pressure across various head elevations provides valuable information, and the readout method is simple enough to be performed by nurses or patient family members.</p>
</sec>
<sec id="s4a7"><label>4.1.7</label><title>Neurovent-P-tel (2009)</title>
<p>Unlike the sensors described above, the final 2 sensors discussed herein, the Neurovent-P-tel and the Miethke Sensor Reservoir (discussed below), have recently been used in clinical settings. Improvements in sensor reliability have enabled their wide adoption. These 2 designs use active electronics to amplify the sensor signal, but unlike the CWRU sensor, they are wirelessly powered. The amplification allows for a more accurate readout and more efficient communication with the external side.</p>
<p>The Neurovent-P-tel was launched by Raumedic (Helmbrechts, Germany) in 2009 (<xref ref-type="bibr" rid="B16">16</xref>). Unlike most other sensors connecting to the CSF shunt system, this freestanding sensor includes a parenchymal catheter. Near the tip of the polyurethane catheter, the piezoresistive pressure sensor is mounted on a flexible membrane. Pressure deforms the membrane, altering the length of the piezoresistors and changing the resistance measurement (<xref ref-type="bibr" rid="B16">16</xref>, <xref ref-type="bibr" rid="B48">48</xref>, <xref ref-type="bibr" rid="B51">51</xref>). The 25-mm catheter is inserted into the parenchyma through a burr hole. As shown in <xref ref-type="fig" rid="F8">Figure&#x00A0;8</xref>, the ceramic disc base rests on the skull surface. When used alongside a shunt, the Neurovent-P-tel is implanted on the opposite hemisphere from the ventricular catheter (<xref ref-type="bibr" rid="B16">16</xref>, <xref ref-type="bibr" rid="B32">32</xref>).</p>
<fig id="F8" position="float"><label>Figure 8</label>
<caption><p>Raumedic Neurovent-P-tel telemetric intracranial pressure (ICP) measurement device (<xref ref-type="bibr" rid="B86">86</xref>). <bold>(A)</bold> Diagram of the sensing catheter used in the Raumedic Neurovent-P-tel. <bold>(B)</bold> The DATALOGGER, also referred to as an interactive display and storage unit. <bold>(C)</bold> Implantable P-tel unit. <bold>(D)</bold> The antenna (reader) unit. <bold>(E)</bold> The Neurovent ICP monitoring system and its placement during an ICP monitoring session. The P-tel catheter is typically implanted in the right or left frontal lobe beneath the scalp, whereas the circular reader is positioned on the skin directly above the catheter and secured with adhesive tape to enable measurement. Figure is in the public domain. Retrieved from doi: 10.1186/s12883-021-02349-8.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fped-13-1632216-g008.tif"><alt-text content-type="machine-generated">Raumedic Neurovent-P-tel telemetric intracranial pressure (ICP) monitoring device. (A) Sensing catheter used in the Neurovent-P-tel system. (B) The DATALOGGER, serving as the display and storage unit. (C) Implantable P-tel unit. (D) Antenna (reader) unit. (E) The complete Neurovent ICP monitoring system in use. The P-tel catheter is typically implanted in the frontal lobe beneath the scalp, while the circular reader is placed on the skin directly above the catheter and secured with adhesive tape to allow pressure measurements.</alt-text>
</graphic>
</fig>
<p>The telemetry unit is housed in ceramic, allowing effective data transmission. Ceramic is impermeable to water vapor, protecting the circuits from corrosion. The ceramic base connects to the silicone-coated polyurethane parenchymal catheter, with the pressure transducer at its distal end (<xref ref-type="bibr" rid="B51">51</xref>). The sensor has a sampling rate of 5&#x2005;Hz, which is lower than that of conventional ICP sensors. This lower sampling rate reduces the resolution of pulse waves for waveform analysis but is sufficient for measuring average ICP (<xref ref-type="bibr" rid="B35">35</xref>). The telemetry system employs a coil antenna and a microchip housed within a ceramic casing. The implanted antenna interacts with the electromagnetic field generated by the external handheld reader unit, and the microchip transmits data by applying load modulation to the implanted antenna. The external reader unit captures the resulting variations on the external antenna (<xref ref-type="bibr" rid="B16">16</xref>). The reader then displays and stores the collected data (<xref ref-type="fig" rid="F8">Figure&#x00A0;8</xref>) (<xref ref-type="bibr" rid="B86">86</xref>).</p>
<p>Preclinical testing demonstrated high accuracy, with zero-point drift of 2.5&#x2005;mm Hg over 18 months (<xref ref-type="bibr" rid="B31">31</xref>, <xref ref-type="bibr" rid="B87">87</xref>). In human studies, zero drift was 4&#x2013;5&#x2005;mm Hg over 11 months (<xref ref-type="bibr" rid="B87">87</xref>). According to manufacturer specifications, the device should not be implanted for more than 90 days. Postapproval monitoring found that the Neurovent-P-tel had a 3.1&#x0025; chance of packaging failure when used for longer recordings. The packaging failures caused drift due to moisture absorption in the analog circuitry. Although there are no reports of patients having been harmed, Raumedic has withdrawn the sensor from long-term use (<xref ref-type="bibr" rid="B88">88</xref>). One of the other reasons behind this withdrawal was early sensor malfunction, more specifically, premature signal failure shortly after implantation, which compromised Neurovent-P-tel&#x0027;s reliability for long-term monitoring (<xref ref-type="bibr" rid="B88">88</xref>).</p>
<p>The Neurovent-P-tel sensor offers several advantages for both in-clinic and at-home care (<xref ref-type="bibr" rid="B89">89</xref>, <xref ref-type="bibr" rid="B90">90</xref>). The sensor is usually reliable for long-term ICP measurement, with minimal zero drift and strong correlation in waveform curve analysis (<xref ref-type="bibr" rid="B87">87</xref>). These characteristics make the sensor well-suited for ICP monitoring during the 8- to 12-week recovery period following ETV. The sensor can measure ICP while the patient is supine or standing, aiding in identifying posture-related over- and under-drainage.</p>
<p>The low sampling frequency of 5&#x2005;Hz poses a disadvantage. This limits pressure curve analysis, although measuring pulse pressure amplitude remains feasible (<xref ref-type="bibr" rid="B90">90</xref>). Baseline drift can compromise accuracy: studies indicate a median shift of 2.5&#x2005;mm Hg from baseline, and the amount of drift is especially large when implant duration exceeds the Conformit&#x00E9; Europ&#x00E9;enne (CE) mark limit of 90 days (<xref ref-type="bibr" rid="B37">37</xref>). This risk is among the factors that led to the device being withdrawn from the market for long-term use (<xref ref-type="bibr" rid="B88">88</xref>). As with all implants, complications can occur: a study of 247 patients found a 1.6&#x0025; risk of superficial wound infection, a 0.8&#x0025; risk of brain abscess, and a 0.4&#x0025; incidence of clinically significant intracerebral hemorrhage, although all complications typically resolved within 2 weeks (<xref ref-type="bibr" rid="B35">35</xref>). The sensor can also become encapsulated by a biological coating on its tip, forming a sleeve that encases the sensor; fortunately, documented instances in clinical practice are rare (<xref ref-type="bibr" rid="B37">37</xref>).</p>
</sec>
<sec id="s4a8"><label>4.1.8</label><title>Miethke Sensor Reservoir (2015)</title>
<p>The Miethke Sensor Reservoir (now marketed under the brand name M.Scio) was introduced in 2015 (<xref ref-type="bibr" rid="B38">38</xref>). Similar to several earlier designs (Radionics TeleSensor, CWRU sensor, Osaka telesensor, Johns Hopkins sensor, and the ICP-Telesensor), this modern sensor is a flow-through device fitting into existing shunt systems. Unlike those earlier designs, the Miethke Sensor Reservoir also replicates the functions of a conventional reservoir: it holds a volume of CSF, the silicone membrane on top can be punctured to withdraw CSF or administer drugs, and the reservoir can be palpated to sense outflow resistance and refilling rate for shunt failure diagnosis. As with the Neurovent-P-tel, the improvements in encapsulation and wirelessly powered sensing and communications electronics have enabled accurate long-term performance.</p>
<p>The Miethke Sensor Reservoir features 2 ports: the inlet connects to the ventricular catheter, and the outlet leads to the valve. The sensing unit is housed in a 12-&#x00B5;m-thick titanium casing within the reservoir. The Miethke Sensor Reservoir uses 64 capacitive pressure sensors. Pressure deforms the flexible diaphragm, altering the gap between the capacitor plates. The resulting change in capacitance is measured by onboard circuitry and correlated back to pressure based on calibration for the sensor size and materials (<xref ref-type="bibr" rid="B91">91</xref>).</p>
<p>The Miethke Sensor Reservoir is a passive battery-free implant that relies on the external handheld reader unit to provide wireless power through magnetic coupling. The handheld reader includes the coil antenna, a display, and storage. A sampling rate of 44&#x2005;Hz allows for the accurate capture of the ICP waveform (<xref ref-type="bibr" rid="B24">24</xref>).</p>
<p>As with all telemetry systems, the advantage of noninvasive sensing is tempered by concerns about accuracy. Prolonged mechanical stress and aging of electronic components can lead to measurement drift. The sensor is rated for implantation for 3 years by CE, having been tested for 2.5 years with a measurement accuracy of 1&#x2005;mm Hg (<xref ref-type="bibr" rid="B35">35</xref>). The system is also unsuited for continuous pressure monitoring because the sensor is passive and requires continuous power by maintaining the reading unit on the correct scalp location.</p>
</sec>
</sec>
<sec id="s4b"><label>4.2</label><title>Clinical implications</title>
<p>The renewed popularity of telemetric ICP monitoring devices began approximately 16 years ago with the licensing of the Neurovent-P-tel (<xref ref-type="bibr" rid="B90">90</xref>). The clinical use of these devices gained more popularity in 2015 with the introduction of Miethke&#x0027;s SR. However, despite their increasing adoption, there are currently no standardized guidelines governing their clinical implementation.</p>
<p>Telemetric ICP monitoring devices have shown applicability in various neurosurgical conditions requiring ICP assessment. They have been used in acute settings such as traumatic brain injury within the intensive care unit, with data quality and long-term stability considered sufficient for clinical decision-making based on average ICP values. In addition to their utility in treating acute pathologies, these devices are valuable in the long-term management of hydrocephalus and other conditions such as craniosynostosis and pseudotumor cerebri (<xref ref-type="bibr" rid="B54">54</xref>, <xref ref-type="bibr" rid="B92">92</xref>).</p>
<p>These devices can be used for diagnostic purposes and to monitor treatment responses. A study by Riedel et al. in which patients with hydrocephalus and coexisting sleep apnea underwent simultaneous ICP recordings and polysomnography provides an example of the diagnostic use of these devices (<xref ref-type="bibr" rid="B93">93</xref>). That study identified that nocturnal transient ICP elevations were associated with sleep apnea and were reduced after continuous positive airway pressure therapy (<xref ref-type="bibr" rid="B93">93</xref>).</p>
<p>Beyond the diagnostic insights that they can provide, these devices are also valuable in predicting treatment outcomes, particularly following ETV. Their ability to provide long-term ICP measurements is especially helpful between postoperative weeks 8 and 12, when ETV failures are most commonly reported (<xref ref-type="bibr" rid="B48">48</xref>, <xref ref-type="bibr" rid="B90">90</xref>). As reported by Antes et al., the Neurovent-P-tel implantation during neuroendoscopic ETV in 25 patients with occlusive hydrocephalus was crucial for distinguishing ETV responders from nonresponders. Six of these patients were identified as nonresponders based on an increase in mean ICP during follow-up. The same study emphasized that continuous ICP monitoring is the safest method for detecting conditions such as shunt malfunction and ETV nonresponsiveness (<xref ref-type="bibr" rid="B16">16</xref>, <xref ref-type="bibr" rid="B21">21</xref>). Furthermore, a key clinical application, central to the focus of our study, is their use in monitoring shunt effectiveness and verifying sustained shunt function over time in patients with complex hydrocephalus (<xref ref-type="bibr" rid="B54">54</xref>).</p>
<p>There are some differences in the clinical applications of the 2 most recent sensors used in telemetric ICP monitoring: the Neurovent-P-tel and the Miethke Sensor Reservoir (<xref ref-type="table" rid="T3">Table&#x00A0;3</xref>). Although the Neurovent-P-tel has an implantation limit of 90 days, the Miethke Sensor Reservoir does not have a strict technical time limitation; however, its CE certification currently permits implantation for up to 3 years (<xref ref-type="bibr" rid="B90">90</xref>). Furthermore, although the Neurovent-P-tel is implanted intraparenchymally and used primarily for diagnostic ICP monitoring, the Miethke Sensor Reservoir must be integrated into a shunt system, and its primary use has been reported as ICP-guided adjustment of shunt valves in adult and pediatric patients with hydrocephalus (<xref ref-type="table" rid="T3">Table&#x00A0;3</xref>) (<xref ref-type="bibr" rid="B38">38</xref>, <xref ref-type="bibr" rid="B90">90</xref>).</p>
<table-wrap id="T3" position="float"><label>Table 3</label>
<caption><p>Comparison of key technical features of the Neurovent-P-tel and Miethke Sensor Reservoir systems.</p></caption>
<table frame="hsides" rules="groups">
<colgroup>
<col align="left"/>
<col align="left"/>
<col align="left"/>
</colgroup>
<thead>
<tr>
<th valign="top" align="left">Feature</th>
<th valign="top" align="center">Raumedic Neurovent-P-tel</th>
<th valign="top" align="center">Miethke Sensor Reservoir</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Implantation duration</td>
<td valign="top" align="left">90 days</td>
<td valign="top" align="left">3 years (CE approval)</td>
</tr>
<tr>
<td valign="top" align="left">Surgical implantation</td>
<td valign="top" align="left">Placed through a frontal burr hole</td>
<td valign="top" align="left">Integrated into a shunt system</td>
</tr>
<tr>
<td valign="top" align="left">Placement</td>
<td valign="top" align="left">Parenchymal</td>
<td valign="top" align="left">Ventricular</td>
</tr>
<tr>
<td valign="top" align="left">Need for additional removal surgery</td>
<td valign="top" align="left">Yes</td>
<td valign="top" align="left">No</td>
</tr>
<tr>
<td valign="top" align="left">Sampling frequency</td>
<td valign="top" align="left">1&#x2013;5&#x2005;Hz</td>
<td valign="top" align="left">40&#x2013;44&#x2005;Hz</td>
</tr>
<tr>
<td valign="top" align="left">Primary clinical application</td>
<td valign="top" align="left">Diagnostic purposes</td>
<td valign="top" align="left">Continuous and repeated ambulatory measurements</td>
</tr>
<tr>
<td valign="top" align="left">Monitoring the success of ETV procedures</td>
<td valign="top" align="left">Can detect drainage-related shunt dysfunction</td>
<td valign="top" align="left">Can guide shunt valve setting adjustments</td>
</tr>
<tr>
<td valign="top" align="left">MRI compatibility</td>
<td valign="top" align="left">Yes, for 1.5 and 3 Tesla</td>
<td valign="top" align="left">Yes, for 1.5 and 3 Tesla (recalibration may be required)</td>
</tr>
<tr>
<td valign="top" align="left">Associated software</td>
<td valign="top" align="left">RAUMED DataView</td>
<td valign="top" align="left">ICPicture</td>
</tr>
<tr>
<td valign="top" align="left">Implant longevity and monitoring utility</td>
<td valign="top" align="left">Extended monitoring periods</td>
<td valign="top" align="left">Extended implant duration allowing for multiple brief ICP assessments</td>
</tr>
<tr>
<td valign="top" align="left">Clinical use</td>
<td valign="top" align="left">Withdrawn from the market</td>
<td valign="top" align="left">Actively in use</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="table-fn14"><p>ETV, endoscopic third ventriculostomy.</p></fn>
</table-wrap-foot>
</table-wrap>
<p>When considering the primary clinical indications for each device, Neurovent-P-tel is best suited for diagnostic purposes or for monitoring the success of ETV procedures. In contrast, the Miethke Sensor Reservoir is more appropriate for continuous or repeated ambulatory measurements, making it ideal for long-term outpatient follow-up. Its clinical value lies in detecting subtle, drainage-related shunt dysfunction and in guiding valve setting adjustments during serial evaluations over extended periods (<xref ref-type="bibr" rid="B90">90</xref>).</p>
<p>The use of the Neurovent-P-tel is relatively simple. Most physicians or nursing staff can be trained within minutes to operate the system. With brief instructions on configuring the display and storage monitor, securing the antenna to the scalp with adhesive tapes or bandages, and supervising patients during monitoring, healthcare providers can easily manage the process (<xref ref-type="bibr" rid="B16">16</xref>). Due to the system&#x0027;s simplicity, many patients can also manage the procedure independently at home. This practicality enables ICP monitoring under everyday conditions (<xref ref-type="bibr" rid="B16">16</xref>). The ICP values measured by the Neurovent-P-tel system can be analyzed using the accompanying software package, RAUMED DataView, which provides basic analysis of ICP measurements, thereby facilitating clinical interpretation (<xref ref-type="bibr" rid="B35">35</xref>). In contrast, the Miethke Sensor Reservoir system is supported by ICPicture software, which enables comprehensive visualization, analysis, and documentation of ICP data (<xref ref-type="bibr" rid="B25">25</xref>).</p>
<p>Despite their clinical utility, these sensors also present certain practical challenges. For instance, the Miethke Sensor Reservoir system utilizes a large radio frequency identification antenna as a part of its reading device, which must be positioned directly over the reservoir to measure and store ICP values (<xref ref-type="bibr" rid="B31">31</xref>, <xref ref-type="bibr" rid="B35">35</xref>). Permanent fixation of this relatively heavy antenna on the patient&#x0027;s head is not feasible, thereby limiting the ability to perform extended ICP monitoring (e.g., overnight or 24&#x2013;48-hour recordings) (<xref ref-type="bibr" rid="B31">31</xref>). Furthermore, due to its height (approximately 7.7&#x2005;mm), undesirable cosmetic outcomes can occur following implantation. A visibly noticeable swelling can develop, and over time, there is a risk of wound dehiscence over the Miethke Sensor Reservoir site (<xref ref-type="bibr" rid="B31">31</xref>).</p>
<p>For Raumedic probes, secure fixation, such as suturing or taping, is necessary to maintain a stable connection during prolonged measurements. If the connection is disrupted, the datalogger is programmed to emit an audible alarm, alerting healthcare providers. Although this feature enhances safety, it can disturb patients and interfere with uninterrupted data acquisition. Therefore, meticulous attention to maintaining secure connections is essential to ensure reliable signal transmission and data continuity (<xref ref-type="bibr" rid="B16">16</xref>).</p>
</sec>
<sec id="s4c"><label>4.3</label><title>Insertion and removal of the most recent telemetric ICP monitoring devices</title>
<p>The surgical implantation of the Neurovent-P-tel is a relatively simple procedure that can be performed under either general or local anesthesia (<xref ref-type="bibr" rid="B16">16</xref>). After a short linear skin incision of approximately 4&#x2005;cm is made, a precoronal parasagittal burr hole is created, through which the catheter is advanced into the frontal brain parenchyma (<xref ref-type="bibr" rid="B16">16</xref>). The final position is reached when the round ceramic housing is seated on the skull surface. It is recommended to close the incision with sutures rather than staples, because metal staples can interfere with the transmission of telemetric ICP data (<xref ref-type="bibr" rid="B16">16</xref>). The entire implantation procedure typically takes around 20 minutes.</p>
<p>Because the Neurovent-P-tel is approved for use for up to 90 days, device removal is required after approximately 3 months (<xref ref-type="bibr" rid="B16">16</xref>). This is also a minor procedure and can be performed under local anesthesia. The previous incision is reopened, and the ceramic housing is exposed. Once the housing is elevated, the probe is carefully withdrawn. To reduce the risk of CSF fistula formation, placement of a gelatin sponge at the removal site is advised. The removal procedure is generally reported to take no longer than 10&#x2005;minutes (<xref ref-type="bibr" rid="B16">16</xref>).</p>
<p>Because the Miethke Sensor Reservoir is integrated into shunt systems and implanted and explanted together with them, they do not require an additional removal surgery (<xref ref-type="bibr" rid="B35">35</xref>).</p>
</sec>
<sec id="s4d"><label>4.4</label><title>Use of the telemetric systems in clinical settings</title>
<p>Use of telemetric systems in clinical settings has been limited, and thus analysis of use does not come from large studies. Most data originate from the Miethke Sensor Reservoir and Neurovent-P-tel systems. Although the Neurovent-P-tel has been withdrawn from the market, the Miethke Sensor Reservoir remains in clinical use.</p>
<p>For both systems, initiating an ICP recording session requires placing the external reader unit over the implanted passive sensor. Once the transducers are activated with radio frequency identification technology, ICP waveforms become immediately visible (<xref ref-type="bibr" rid="B35">35</xref>). For the Neurovent-P-tel, securing the reader unit with a bandage helps maintain stable and uninterrupted monitoring sessions, especially for long-term use. The system can typically store up to 3 days of data before reaching full storage capacity. In contrast, establishing long-term recordings with the Miethke Sensor Reservoir system can be more challenging, because the reader unit can easily lose connection with the implant. To obtain reliable readings, the reader must be held at a specific distance from the implant (<xref ref-type="bibr" rid="B35">35</xref>). However, short-term positional measurements are feasible by manually holding the reader at the appropriate angle and proximity. The Miethke Sensor Reservoir system can store 40&#x2005;hours of data (<xref ref-type="bibr" rid="B35">35</xref>).</p>
</sec>
<sec id="s4e"><label>4.5</label><title>Advantages and disadvantages of telemetric ICP monitoring systems</title>
<p>Numerous studies have reported the benefits of ICP-guided adjustments in optimizing shunt settings and improving long-term patient management (<xref ref-type="bibr" rid="B16">16</xref>, <xref ref-type="bibr" rid="B24">24</xref>, <xref ref-type="bibr" rid="B25">25</xref>, <xref ref-type="bibr" rid="B32">32</xref>, <xref ref-type="bibr" rid="B33">33</xref>, <xref ref-type="bibr" rid="B37">37</xref>, <xref ref-type="bibr" rid="B38">38</xref>, <xref ref-type="bibr" rid="B50">50</xref>). Conventional ICP measurement methods, such as external ventricular drains (EVDs) or wired ICP probes, are invasive, pose a risk of infection, and are limited to short-term use (typically around 10 days for conventional probes). Additionally, they require hospital-based settings due to their dependence on intensive care unit infrastructure. Unlike conventional methods, which can require multiple interventions, telemetric sensors provide a minimally invasive alternative. They enable long-term monitoring beyond the hospital without restricting patient mobility. These methods stand out for their ability to monitor ICP in both hospital and home settings (<xref ref-type="bibr" rid="B21">21</xref>, <xref ref-type="bibr" rid="B51">51</xref>). By wirelessly transmitting data collected through various techniques, they facilitate long-term ICP monitoring even during daily activities and different postures (e.g., lying, sitting, standing) (<xref ref-type="bibr" rid="B25">25</xref>, <xref ref-type="bibr" rid="B41">41</xref>, <xref ref-type="bibr" rid="B50">50</xref>).</p>
<p>A recent systematic review by Omidbeigi et al. reported the complication rate associated with telemetric ICP monitoring devices to be 7.1&#x0025; (<xref ref-type="bibr" rid="B94">94</xref>). In comparison, EVD and conventional intraparenchymal ICP monitoring were associated with complication rates of 14.5&#x0025; and 10&#x0025;, respectively (<xref ref-type="bibr" rid="B95">95</xref>, <xref ref-type="bibr" rid="B96">96</xref>). Among studies involving telemetric ICP devices, the most frequently observed complication was a single new-onset seizure, occurring in 3.9&#x0025; of cases (<xref ref-type="bibr" rid="B51">51</xref>). Reported infection rates for EVDs range from 7.3&#x0025; to 10.4&#x0025;, with a notable increase linked to prolonged monitoring duration (<xref ref-type="bibr" rid="B97">97</xref>&#x2013;<xref ref-type="bibr" rid="B100">100</xref>). Hemorrhage associated with EVD placement has been documented at rates ranging between 0.7&#x0025; and 41.0&#x0025;, influenced by factors such as monitoring time, imaging protocols, and patient-specific variables (<xref ref-type="bibr" rid="B97">97</xref>, <xref ref-type="bibr" rid="B100">100</xref>). In contrast, reported rates of infection and hemorrhage associated with ICP monitoring devices were both 1.6&#x0025; (<xref ref-type="bibr" rid="B94">94</xref>). However, Antes et al. observed higher incidences of bleeding and infection in patients monitored with Neurovent-P-tel sensors compared to those using conventional intraparenchymal probes (<xref ref-type="bibr" rid="B51">51</xref>).</p>
<p>Another important advantage of long-term ICP monitoring with telemetric sensors is preventing unnecessary invasive interventions when clinical and radiological findings are nonspecific and insufficient to detect ICP changes (<xref ref-type="bibr" rid="B27">27</xref>, <xref ref-type="bibr" rid="B41">41</xref>). For example, Korfias et al. stated that patients with normal ICP recordings acquired with telemetric sensors could avoid unnecessary shunt implantations, preventing them from becoming potential &#x201C;shunt-dependents&#x201D; for the rest of their lives and mitigating the associated long-term complications (<xref ref-type="bibr" rid="B27">27</xref>). Additionally, educating families and patients about ICP monitoring can enhance their role in the treatment process, particularly in pediatric cases (<xref ref-type="bibr" rid="B21">21</xref>). This awareness allows patients and their families to make more informed decisions when nonspecific clinical symptoms arise, which has been shown to reduce hospital admission rates, healthcare costs, and anxiety during the treatment process (<xref ref-type="bibr" rid="B21">21</xref>, <xref ref-type="bibr" rid="B46">46</xref>).</p>
<p>A noteworthy advantage of the Neurovent-P-tel system is that it requires no calibration and is magnetic resonance imaging (MRI)-compatible at both 1.5 and 3-Tesla (<xref ref-type="bibr" rid="B90">90</xref>). The Miethke Sensor Reservoir is also MRI-compatible at the same field strengths, although it can require postimaging recalibration (<xref ref-type="bibr" rid="B101">101</xref>). However, further studies are needed to verify the MRI compatibility of other telemetric ICP monitoring devices. Furthermore, for Neurovent-P-tel, ICP values can be reliably obtained either through wound dressings or directly over intact skin, with no significant differences reported. However, clinicians should be aware that the device can be sensitive to ambient temperature changes and performs optimally within a range of 15&#x00B0;C&#x2013;45&#x00B0;C (<xref ref-type="bibr" rid="B54">54</xref>). Additionally, if continuous monitoring is not required for a few hours, the system can be temporarily disengaged by removing the reader and recorder units (<xref ref-type="bibr" rid="B54">54</xref>).</p>
<p>Continuous ICP monitoring is particularly advantageous in pediatric patients during long-term follow-up because it can detect subtle increases in ICP that might not be evident through clinical and radiological findings (<xref ref-type="bibr" rid="B27">27</xref>, <xref ref-type="bibr" rid="B44">44</xref>). Undetected ICP elevation can harm the developing brain, making continuous monitoring crucial for this vulnerable population (<xref ref-type="bibr" rid="B33">33</xref>, <xref ref-type="bibr" rid="B59">59</xref>).</p>
<p>As highlighted in clinical studies, these devices might enhance diagnostic accuracy and improve therapeutic outcomes. Numerous heterogeneous factors that affect shunt drainage, including intraventricular pressure and valve and tube resistances, complicate optimal valve adjustment (<xref ref-type="bibr" rid="B32">32</xref>, <xref ref-type="bibr" rid="B102">102</xref>). These problems can lead to complications such as over- and underdrainage, which are associated with various adverse outcomes. To overcome these issues, data acquired from long-term ICP monitoring has been used to fine-tune shunt drainage volumes effectively, a practice successfully demonstrated in previous studies (<xref ref-type="bibr" rid="B16">16</xref>, <xref ref-type="bibr" rid="B27">27</xref>, <xref ref-type="bibr" rid="B31">31</xref>, <xref ref-type="bibr" rid="B34">34</xref>, <xref ref-type="bibr" rid="B38">38</xref>, <xref ref-type="bibr" rid="B102">102</xref>). Moreover, considering all these factors, telemetric sensors assist in planning patient-based treatment approaches by assessing preoperative and postoperative ICP changes in relation to circadian and position-related factors, thereby facilitating the selection of appropriate valves and adjusting valve settings accordingly (<xref ref-type="bibr" rid="B33">33</xref>, <xref ref-type="bibr" rid="B79">79</xref>, <xref ref-type="bibr" rid="B102">102</xref>).</p>
<p>Additionally, studies have explored the impact of telesensors on service demand and financial outcomes compared with nontelemetric reservoirs (<xref ref-type="bibr" rid="B22">22</xref>, <xref ref-type="bibr" rid="B39">39</xref>). Most recently, Pandit et al. demonstrated that using telemetric ICP sensors resulted in significant cost savings and improved resource utilization (<xref ref-type="bibr" rid="B22">22</xref>). The study indicates that patients monitored with telesensors required fewer hospital admissions and invasive procedures, such as shunt revisions, further highlighting the potential of these devices to improve both clinical and financial outcomes.</p>
<p>The main challenges associated with telemetric devices include high initial costs that limit accessibility in some healthcare systems, patient discomfort, lack of standardized protocols, and the need for specialized training to interpret data effectively (<xref ref-type="bibr" rid="B21">21</xref>, <xref ref-type="bibr" rid="B22">22</xref>, <xref ref-type="bibr" rid="B24">24</xref>). Additionally, intraparenchymal telemetric devices, such as Neurovent-P-tel, have been reported to cause perifocal minor edematous reactions due to factors like initial local tissue trauma during insertion and brain pulsation (<xref ref-type="bibr" rid="B27">27</xref>, <xref ref-type="bibr" rid="B51">51</xref>). This edema is generally self-resolving, as reported in a study by Korfias et al. in 2021, but this issue requires further research to understand the long-term implications (<xref ref-type="bibr" rid="B27">27</xref>).</p>
<p>Due to substantial heterogeneity in patient populations, study methodologies, and outcome measures across the existing literature, drawing definitive comparisons between telemetric and conventional ICP monitoring techniques remains challenging. Further prospective, standardized investigations are necessary to more accurately assess the relative safety and clinical utility of telemetric ICP monitoring systems. In light of all these factors, the indications for telemetric sensors do not apply to all ICP-related cases; telemetric sensors are best suited to scenarios requiring multiple monitoring sessions or, as noted in numerous studies, select patients who would benefit from long-term monitoring (<xref ref-type="bibr" rid="B16">16</xref>, <xref ref-type="bibr" rid="B25">25</xref>, <xref ref-type="bibr" rid="B27">27</xref>, <xref ref-type="bibr" rid="B37">37</xref>, <xref ref-type="bibr" rid="B48">48</xref>, <xref ref-type="bibr" rid="B49">49</xref>).</p>
</sec>
<sec id="s4f"><label>4.6</label><title>Future directions</title>
<p>Telemetric ICP monitoring simplifies the management of patients with hydrocephalus who require complex care by providing real-time data on intracranial dynamics, benefiting physicians and patients. However, the literature offers limited indications for different hydrocephalus subtypes. Although telemetric ICP monitoring is recommended for cases that require long-term ICP monitoring, more studies are needed to define its broader applications (<xref ref-type="bibr" rid="B16">16</xref>, <xref ref-type="bibr" rid="B58">58</xref>, <xref ref-type="bibr" rid="B61">61</xref>, <xref ref-type="bibr" rid="B63">63</xref>, <xref ref-type="bibr" rid="B102">102</xref>).</p>
<p>In recent years, artificial intelligence algorithms have become increasingly widespread in neurosurgery, paving the way for the potential development of fully integrated systems (<xref ref-type="bibr" rid="B103">103</xref>, <xref ref-type="bibr" rid="B104">104</xref>). Future studies should focus on developing a fully integrated system capable of directly measuring ICP and dynamically adjusting the shunt function. Such a system could transform the care of shunt-treated patients by enabling real-time shunt adjustments and minimizing the risks of under- and overdrainage by analyzing complex ICP curves to detect malfunctions.</p>
<p>Although telemetric devices are highly useful and often regarded as problem-solving tools, several technical limitations remain that should be addressed in future studies. For example, the sampling frequency of these devices is significantly lower than that of conventional ICP measurement systems (<xref ref-type="bibr" rid="B90">90</xref>). This might potentially reduce the accuracy of the overall recorded data. Additionally, the risk of zero drifting, a gradual deviation of the baseline pressure reading, is a critical concern. Although this issue is also present in conventional systems, it could be more pronounced in telemetric devices due to their longer implantation duration (<xref ref-type="bibr" rid="B90">90</xref>). Increasing the sampling frequency in future iterations of these devices could contribute to more objective and accurate measurements.</p>
<p>Another major limitation is the lack of a standardized software platform to analyze the recorded ICP data (<xref ref-type="bibr" rid="B90">90</xref>). There is no universally accepted tool for interpreting telemetric readings in a consistent and clinically meaningful manner. Future research should aim to develop such standardized analysis programs, which would enhance data interpretation and clinical decision-making.</p>
<p>Additionally, efforts should focus on enhancing the miniaturization of implanted probes and their long-term biocompatibility to enable true wireless functionality, allowing direct data transmission from the implanted device without requiring interaction with the patient. From the patient&#x0027;s perspective, the potential of telemetric devices to reduce the number of routine medical visits, invasive procedures, and radiation exposure improves patient experience and safety. Although these innovations are hypothesized to yield cost savings in long-term management, more studies are necessary to validate this hypothesis and explore their economic impact in different clinical settings (<xref ref-type="bibr" rid="B33">33</xref>).</p>
<p>Also, to address common challenges associated with these probes, specific preventive strategies can be considered. For instance, to mitigate the disconnection issues frequently encountered with some of these devices, more secure anchoring techniques could be developed, and less invasive fixation methods could be explored. These improvements might help prevent accidental disconnections or positional shifts during monitoring.</p>
<p>Although complications such as brain-pulsation-induced injuries or perifocal edema, with a reported incidence of up to 47&#x0025;, can also occur with conventional ICP monitoring methods, they are typically less prominent because of the short-term nature of these techniques (<xref ref-type="bibr" rid="B51">51</xref>). Regarding the safety of telemetric ICP monitoring devices, prospective clinical and biomechanical studies are essential to assess long-term complications, including edematous reactions, infections, and hemorrhages, particularly in pediatric patients (<xref ref-type="bibr" rid="B51">51</xref>).</p>
<p>Technical problems related to ICP measurements, such as sensor drift and zero-point variation, must also be addressed. Zero-point variation is a shift in baseline measurements that can compromise reliability, particularly in long-term monitoring. Zero-point drift resulting from material fatigue, fluid ingress into electronics, and temperature variations has historically posed a significant obstacle to the sustained use of telemetric ICP devices (<xref ref-type="bibr" rid="B33">33</xref>). Although reengineered designs have mitigated this issue, studies have shown that telemetric devices can deviate by 4&#x2005;mm Hg from absolute ICP values because of differences in measurement locations and technical factors (<xref ref-type="bibr" rid="B16">16</xref>, <xref ref-type="bibr" rid="B33">33</xref>). Ongoing work in entirely passive circuit design could enable recalibration by switched reference signals (<xref ref-type="bibr" rid="B105">105</xref>). Integrating more durable materials and dynamic calibration systems could further reduce these challenges, enhance measurement accuracy, improve patient outcomes, and support the broader clinical adoption of telemetric ICP devices.</p>
<p>Numerous studies have highlighted that ICP-guided valve adjustments achieved through telemetric sensors hold significant promise for the future of hydrocephalus management. Although challenges related to high initial costs, uncomfortable devices, and data interpretation remain (<xref ref-type="bibr" rid="B22">22</xref>&#x2013;<xref ref-type="bibr" rid="B24">24</xref>), the benefits of continuous monitoring and improved patient outcomes underline telemetry&#x0027;s potential. Telemetry&#x0027;s role in improving outcomes and reducing invasive procedures is transformational in the care of patients with hydrocephalus (<xref ref-type="bibr" rid="B16">16</xref>, <xref ref-type="bibr" rid="B25">25</xref>, <xref ref-type="bibr" rid="B48">48</xref>, <xref ref-type="bibr" rid="B49">49</xref>). Addressing these challenges and refining measurement techniques will likely enhance patient outcomes while increasing efficiency in the delivery of healthcare services.</p>
<p>Although our study focuses on direct telemetric monitoring of ICP, various indirect methods are also emerging to predict elevated ICP and delayed cerebral ischemia, particularly through advanced imaging-based assessments (<xref ref-type="bibr" rid="B106">106</xref>). Recent efforts have introduced imaging-derived indices to evaluate cerebral hemodynamics and stratify the risks of hydrocephalus, vasospasm, delayed cerebral ischemia, and poor functional outcomes after aneurysmal subarachnoid hemorrhage. One such tool is the cortical vein opacification score, a semi-quantitative CT angiography&#x2013;based scoring system that assesses cortical venous filling and has shown prognostic value in this patient population (<xref ref-type="bibr" rid="B106">106</xref>). This score can serve as a radiologic surrogate of intracranial venous flow patterns. Lower cortical vein opacification scores can reflect delayed cerebral ischemia or suspected ICP elevation, and they could be indirectly associated with an increased risk of hydrocephalus development, although further studies with larger sample sizes are needed to evaluate this association (<xref ref-type="bibr" rid="B106">106</xref>). Additional studies are warranted to determine whether such imaging-based tools can complement telemetric ICP monitoring, particularly in diagnostically challenging or equivocal cases of hydrocephalus secondary to aneurysmal subarachnoid hemorrhage.</p>
<p>Lastly, it is worth noting that the existing literature primarily consists of patient cohorts and case reports that combine adult and pediatric populations, limiting understanding of pediatric-specific outcomes. More studies are needed to evaluate the effectiveness of these devices in managing specific patient populations, such as pediatric patients.</p>
</sec>
</sec>
<sec id="s5"><label>5</label><title>Conclusions</title>
<p>Telemetric ICP monitoring represents a significant advancement in the management of hydrocephalus, addressing the limitations of conventional invasive methods by providing long-term, wireless pressure measurements. This study found growing clinical adoption of these devices. The ability to monitor ICP in real-world conditions has led to improved patient outcomes, fewer unnecessary interventions, and reduced healthcare costs. However, challenges such as sensor drift, standardization of clinical protocols, and cost barriers must be addressed through continued research and technological advancements. Future studies should focus on refining device accuracy, expanding indications for use, and integrating telemetric monitoring into broader neurosurgical practices. As these technologies evolve, they should be expected to transform hydrocephalus management and optimize neurosurgical care.</p>
</sec>
</body>
<back>
<sec id="s6" sec-type="author-contributions"><title>Author contributions</title>
<p>KY: Conceptualization, Formal analysis, Methodology, Resources, Validation, Writing &#x2013; original draft, Writing &#x2013; review &#x0026; editing. DWG: Conceptualization, Methodology, Software, Validation, Visualization, Writing &#x2013; original draft, Writing &#x2013; review &#x0026; editing. CECV: Data curation, Formal analysis, Writing &#x2013; review &#x0026; editing. EG: Data curation, Formal analysis, Writing &#x2013; review &#x0026; editing. MCD: Formal analysis, Investigation, Software, Visualization, Writing &#x2013; original draft. IB: Software, Visualization, Writing &#x2013; original draft. TJO: Investigation, Software, Writing &#x2013; original draft. MCP: Funding acquisition, Project administration, Resources, Supervision, Writing &#x2013; review &#x0026; editing.</p>
</sec>
<sec id="s7" sec-type="funding-information"><title>Funding</title>
<p>The author(s) declare that financial support was received for the research and/or publication of this article. This study was supported by the Newsome Chair in Neurosurgery Research held by Dr. Preul and funds from the Barrow Neurological Foundation.</p>
</sec>
<ack><title>Acknowledgments</title>
<p>We thank the staff of Neuroscience Publications at Barrow Neurological Institute for assistance with manuscript preparation.</p>
</ack>
<sec id="s8" sec-type="COI-statement"><title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
<p>The author(s) declared that they were an editorial board member of Frontiers, at the time of submission. This had no impact on the peer review process and the final decision.</p>
</sec>
<sec id="s9" sec-type="ai-statement"><title>Generative AI statement</title>
<p>The author(s) declare that no Generative AI was used in the creation of this manuscript.</p>
<p>Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issue please contact us.</p>
</sec>
<sec id="s10" sec-type="disclaimer"><title>Publisher&#x0027;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<fn-group>
<title>Abbreviations</title>
<fn fn-type="abbr" id="ab001"><p>CE, Conformit&#x00E9; Europ&#x00E9;enne; CSF, cerebrospinal fluid; CT, computed tomography; CWRU, Case Western Reserve University; ETV, endoscopic third ventriculostomy; ICP, intracranial pressure; MRI, magnetic resonance imaging; RTT, Rotterdam Teletransducer.</p></fn>
</fn-group>
<ref-list><title>References</title>
<ref id="B1"><label>1.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Rekate</surname><given-names>HL</given-names></name></person-group>. <article-title>A contemporary definition and classification of hydrocephalus</article-title>. <source>Semin Pediatr Neurol</source>. (<year>2009</year>) <volume>16</volume>(<issue>1</issue>):<fpage>9</fpage>&#x2013;<lpage>15</lpage>. <pub-id pub-id-type="doi">10.1016/j.spen.2009.01.002</pub-id><pub-id pub-id-type="pmid">19410151</pub-id></citation></ref>
<ref id="B2"><label>2.</label><citation citation-type="book"><person-group person-group-type="author"><name><surname>Koleva</surname><given-names>M</given-names></name><name><surname>De Jesus</surname><given-names>O</given-names></name></person-group>. <source>Hydrocephalus</source>. <publisher-loc>Treasure Island, FL</publisher-loc>: <publisher-name>StatPearls</publisher-name> (<year>2025</year>).</citation></ref>
<ref id="B3"><label>3.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dandy</surname><given-names>WE</given-names></name></person-group>. <article-title>An experimental and clinical study of internal hydrocephalus</article-title>. <source>JAMA</source>. (<year>1913</year>) <volume>61</volume>(<issue>25</issue>):<fpage>2216</fpage>&#x2013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1001/jama.1913.04350260014006</pub-id></citation></ref>
<ref id="B4"><label>4.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Williams</surname><given-names>MA</given-names></name></person-group>. <article-title>Adult hydrocephalus clinical subtypes</article-title>. <source>Neurosurg Clin N Am</source>. (<year>2025</year>) <volume>36</volume>(<issue>2</issue>):<fpage>149</fpage>&#x2013;<lpage>55</lpage>. <pub-id pub-id-type="doi">10.1016/j.nec.2024.12.005</pub-id><pub-id pub-id-type="pmid">40054969</pub-id></citation></ref>
<ref id="B5"><label>5.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Vinchon</surname><given-names>M</given-names></name><name><surname>Rekate</surname><given-names>H</given-names></name><name><surname>Kulkarni</surname><given-names>AV</given-names></name></person-group>. <article-title>Pediatric hydrocephalus outcomes: a review</article-title>. <source>Fluids Barriers CNS</source>. (<year>2012</year>) <volume>9</volume>(<issue>1</issue>):<fpage>18</fpage>. <pub-id pub-id-type="doi">10.1186/2045-8118-9-18</pub-id><pub-id pub-id-type="pmid">22925451</pub-id></citation></ref>
<ref id="B6"><label>6.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hamilton</surname><given-names>MG</given-names></name></person-group>. <article-title>Treatment of hydrocephalus in adults</article-title>. <source>Semin Pediatr Neurol</source>. (<year>2009</year>) <volume>16</volume>(<issue>1</issue>):<fpage>34</fpage>&#x2013;<lpage>41</lpage>. <pub-id pub-id-type="doi">10.1016/j.spen.2009.02.001</pub-id><pub-id pub-id-type="pmid">19410156</pub-id></citation></ref>
<ref id="B7"><label>7.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kahle</surname><given-names>KT</given-names></name><name><surname>Kulkarni</surname><given-names>AV</given-names></name><name><surname>Limbrick</surname><given-names>DD</given-names><suffix>Jr.</suffix></name><name><surname>Warf</surname><given-names>BC</given-names></name></person-group>. <article-title>Hydrocephalus in children</article-title>. <source>Lancet</source>. (<year>2016</year>) <volume>387</volume>(<issue>10020</issue>):<fpage>788</fpage>&#x2013;<lpage>99</lpage>. <pub-id pub-id-type="doi">10.1016/s0140-6736(15)60694-8</pub-id><pub-id pub-id-type="pmid">26256071</pub-id></citation></ref>
<ref id="B8"><label>8.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Faquini</surname><given-names>IV</given-names></name><name><surname>Fonseca</surname><given-names>RB</given-names></name><name><surname>Correia</surname><given-names>AO</given-names></name><name><surname>Cezar Junior</surname><given-names>AB</given-names></name><name><surname>De Carvalho Junior</surname><given-names>EV</given-names></name><name><surname>de Almeida</surname><given-names>NS</given-names></name><etal/></person-group> <article-title>Endoscopic third ventriculostomy in the treatment of hydrocephalus: a 20-year retrospective analysis of 209 consecutive cases</article-title>. <source>Surg Neurol Int</source>. (<year>2021</year>) <volume>12</volume>:<fpage>383</fpage>. <pub-id pub-id-type="doi">10.25259/sni_458_2021</pub-id><pub-id pub-id-type="pmid">34513150</pub-id></citation></ref>
<ref id="B9"><label>9.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Khawari</surname><given-names>S</given-names></name><name><surname>Pandit</surname><given-names>A</given-names></name><name><surname>Watkins</surname><given-names>L</given-names></name><name><surname>Toma</surname><given-names>A</given-names></name><name><surname>Thorne</surname><given-names>L</given-names></name></person-group>. <article-title>Can clinicians correctly predict intracranial pressure state based on clinical symptoms alone in shunted patients?</article-title> <source>J Neurosurg Sci</source>. (<year>2025</year>) <volume>69</volume>(<issue>1</issue>):<fpage>131</fpage>&#x2013;<lpage>5</lpage>. <pub-id pub-id-type="doi">10.23736/S0390-5616.23.06065-4</pub-id><pub-id pub-id-type="pmid">37997322</pub-id></citation></ref>
<ref id="B10"><label>10.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Brody</surname><given-names>AS</given-names></name><name><surname>Frush</surname><given-names>DP</given-names></name><name><surname>Huda</surname><given-names>W</given-names></name><name><surname>Brent</surname><given-names>RL</given-names></name></person-group>, <collab>American Academy of Pediatrics Section on R</collab>. <article-title>Radiation risk to children from computed tomography</article-title>. <source>Pediatrics</source>. (<year>2007</year>) <volume>120</volume>(<issue>3</issue>):<fpage>677</fpage>&#x2013;<lpage>82</lpage>. <pub-id pub-id-type="doi">10.1542/peds.2007-1910</pub-id><pub-id pub-id-type="pmid">17766543</pub-id></citation></ref>
<ref id="B11"><label>11.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Meulepas</surname><given-names>JM</given-names></name><name><surname>Ronckers</surname><given-names>CM</given-names></name><name><surname>Smets</surname><given-names>A</given-names></name><name><surname>Nievelstein</surname><given-names>RAJ</given-names></name><name><surname>Gradowska</surname><given-names>P</given-names></name><name><surname>Lee</surname><given-names>C</given-names></name><etal/></person-group> <article-title>Radiation exposure from pediatric CT scans and subsequent cancer risk in The Netherlands</article-title>. <source>J Natl Cancer Inst</source>. (<year>2019</year>) <volume>111</volume>(<issue>3</issue>):<fpage>256</fpage>&#x2013;<lpage>63</lpage>. <pub-id pub-id-type="doi">10.1093/jnci/djy104</pub-id><pub-id pub-id-type="pmid">30020493</pub-id></citation></ref>
<ref id="B12"><label>12.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Aiolfi</surname><given-names>A</given-names></name><name><surname>Benjamin</surname><given-names>E</given-names></name><name><surname>Khor</surname><given-names>D</given-names></name><name><surname>Inaba</surname><given-names>K</given-names></name><name><surname>Lam</surname><given-names>L</given-names></name><name><surname>Demetriades</surname><given-names>D</given-names></name></person-group>. <article-title>Brain Trauma Foundation guidelines for intracranial pressure monitoring: compliance and effect on outcome</article-title>. <source>World J Surg</source>. (<year>2017</year>) <volume>41</volume>(<issue>6</issue>):<fpage>1543</fpage>&#x2013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1007/s00268-017-3898-6</pub-id><pub-id pub-id-type="pmid">28188356</pub-id></citation></ref>
<ref id="B13"><label>13.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mackay</surname><given-names>RS</given-names></name></person-group>. <article-title>Radio telemetering from within the body: inside information is revealed by tiny transmitters that can be swallowed or implanted in man or animal</article-title>. <source>Science</source>. (<year>1961</year>) <volume>134</volume>(<issue>3486</issue>):<fpage>1196</fpage>&#x2013;<lpage>202</lpage>. <pub-id pub-id-type="doi">10.1126/science.134.3486.1196</pub-id><pub-id pub-id-type="pmid">17753692</pub-id></citation></ref>
<ref id="B14"><label>14.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Atkinson</surname><given-names>JR</given-names></name><name><surname>Shurtleff</surname><given-names>DB</given-names></name><name><surname>Foltz</surname><given-names>EL</given-names></name></person-group>. <article-title>Radio telemetry for the measurement of intracranial pressure</article-title>. <source>J Neurosurg</source>. (<year>1967</year>) <volume>27</volume>(<issue>5</issue>):<fpage>428</fpage>&#x2013;<lpage>32</lpage>. <pub-id pub-id-type="doi">10.3171/jns.1967.27.5.0428</pub-id><pub-id pub-id-type="pmid">6059415</pub-id></citation></ref>
<ref id="B15"><label>15.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Olsen</surname><given-names>ER</given-names></name><name><surname>Collins</surname><given-names>CC</given-names></name><name><surname>Loughborough</surname><given-names>WF</given-names></name><name><surname>Richards</surname><given-names>V</given-names></name><name><surname>Adams</surname><given-names>JE</given-names></name><name><surname>Pinto</surname><given-names>DW</given-names></name></person-group>. <article-title>Intracranial pressure measurement with a miniature passive implanted pressure transensor</article-title>. <source>Am J Surg</source>. (<year>1967</year>) <volume>113</volume>(<issue>6</issue>):<fpage>727</fpage>&#x2013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1016/0002-9610(67)90334-0</pub-id><pub-id pub-id-type="pmid">4960729</pub-id></citation></ref>
<ref id="B16"><label>16.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Antes</surname><given-names>S</given-names></name><name><surname>Tschan</surname><given-names>CA</given-names></name><name><surname>Heckelmann</surname><given-names>M</given-names></name><name><surname>Breuskin</surname><given-names>D</given-names></name><name><surname>Oertel</surname><given-names>J</given-names></name></person-group>. <article-title>Telemetric intracranial pressure monitoring with the Raumedic Neurovent-P-tel</article-title>. <source>World Neurosurg</source>. (<year>2016</year>) <volume>91</volume>:<fpage>133</fpage>&#x2013;<lpage>48</lpage>. <pub-id pub-id-type="doi">10.1016/j.wneu.2016.03.096</pub-id><pub-id pub-id-type="pmid">27060515</pub-id></citation></ref>
<ref id="B17"><label>17.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kiefer</surname><given-names>M</given-names></name><name><surname>Antes</surname><given-names>S</given-names></name><name><surname>Leonhardt</surname><given-names>S</given-names></name><name><surname>Schmitt</surname><given-names>M</given-names></name><name><surname>Orakcioglu</surname><given-names>B</given-names></name><name><surname>Sakowitz</surname><given-names>OW</given-names></name><etal/></person-group> <article-title>Telemetric ICP measurement with the first CE-approved device: data from animal experiments and initial clinical experiences</article-title>. <source>Acta Neurochir Suppl</source>. (<year>2012</year>) <volume>114</volume>:<fpage>111</fpage>&#x2013;<lpage>6</lpage>. <pub-id pub-id-type="doi">10.1007/978-3-7091-0956-4_20</pub-id><pub-id pub-id-type="pmid">22327674</pub-id></citation></ref>
<ref id="B18"><label>18.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kiefer</surname><given-names>M</given-names></name><name><surname>Antes</surname><given-names>S</given-names></name><name><surname>Schmitt</surname><given-names>M</given-names></name><name><surname>Krause</surname><given-names>I</given-names></name><name><surname>Eymann</surname><given-names>R</given-names></name></person-group>. <article-title>Long-term performance of a CE-approved telemetric intracranial pressure monitoring</article-title>. <source>Annu Int Conf IEEE Eng Med Biol Soc</source>. (<year>2011</year>) <volume>2011</volume>:<fpage>2246</fpage>&#x2013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1109/iembs.2011.6090426</pub-id><pub-id pub-id-type="pmid">22254787</pub-id></citation></ref>
<ref id="B19"><label>19.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Moher</surname><given-names>D</given-names></name><name><surname>Liberati</surname><given-names>A</given-names></name><name><surname>Tetzlaff</surname><given-names>J</given-names></name><name><surname>Altman</surname><given-names>DG</given-names></name><name><surname>Group</surname><given-names>P</given-names></name></person-group>. <article-title>Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement</article-title>. <source>PLoS Med</source>. (<year>2009</year>) <volume>6</volume>(<issue>7</issue>):<fpage>e1000097</fpage>. <pub-id pub-id-type="doi">10.1371/journal.pmed.1000097</pub-id><pub-id pub-id-type="pmid">19621072</pub-id></citation></ref>
<ref id="B20"><label>20.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Horsley</surname><given-names>T</given-names></name><name><surname>Dingwall</surname><given-names>O</given-names></name><name><surname>Sampson</surname><given-names>M</given-names></name></person-group>. <article-title>Checking reference lists to find additional studies for systematic reviews</article-title>. <source>Cochrane Database Syst Rev</source>. (<year>2011</year>) <volume>2011</volume>(<issue>8</issue>):<fpage>Mr000026</fpage>. <pub-id pub-id-type="doi">10.1002/14651858.MR000026.pub2</pub-id><pub-id pub-id-type="pmid">21833989</pub-id></citation></ref>
<ref id="B21"><label>21.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pedersen</surname><given-names>SH</given-names></name><name><surname>Henriksen</surname><given-names>KA</given-names></name><name><surname>Gustafsen</surname><given-names>SD</given-names></name><name><surname>Hansen</surname><given-names>TS</given-names></name><name><surname>Guldager</surname><given-names>R</given-names></name><name><surname>Juhler</surname><given-names>M</given-names></name></person-group>. <article-title>Telemetric ICP monitoring in children: a national questionnaire-based study</article-title>. <source>Childs Nerv Syst</source>. (<year>2024</year>) <volume>40</volume>(<issue>8</issue>):<fpage>2391</fpage>&#x2013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1007/s00381-024-06383-y</pub-id><pub-id pub-id-type="pmid">38587626</pub-id></citation></ref>
<ref id="B22"><label>22.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pandit</surname><given-names>AS</given-names></name><name><surname>Kamal</surname><given-names>MA</given-names></name><name><surname>Reischer</surname><given-names>G</given-names></name><name><surname>Aldabbagh</surname><given-names>Y</given-names></name><name><surname>Alradhawi</surname><given-names>M</given-names></name><name><surname>Lee</surname><given-names>FMY</given-names></name><etal/></person-group> <article-title>The impact of intracranial pressure telesensors: an observational propensity-matched control analysis of service demand and costs</article-title>. <source>Neurosurgery</source>. (<year>2024</year>) <volume>95</volume>(<issue>1</issue>):<fpage>224</fpage>&#x2013;<lpage>33</lpage>. <pub-id pub-id-type="doi">10.1227/neu.0000000000002893</pub-id><pub-id pub-id-type="pmid">38445908</pub-id></citation></ref>
<ref id="B23"><label>23.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hornsh&#x00F8;j Pedersen</surname><given-names>S</given-names></name><name><surname>Gustafsen</surname><given-names>SD</given-names></name><name><surname>Juhler</surname><given-names>M</given-names></name><name><surname>Guldager</surname><given-names>R</given-names></name></person-group>. <article-title>Parent perception of telemetric intracranial pressure monitoring in children - a qualitative case study</article-title>. <source>Brain Spine</source>. (<year>2024</year>) <volume>4</volume>:<fpage>102820</fpage>. <pub-id pub-id-type="doi">10.1016/j.bas.2024.102820</pub-id></citation></ref>
<ref id="B24"><label>24.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jirlow</surname><given-names>U</given-names></name><name><surname>Arvidsson</surname><given-names>L</given-names></name><name><surname>Magneli</surname><given-names>S</given-names></name><name><surname>Cesarini</surname><given-names>K</given-names></name><name><surname>Rostami</surname><given-names>E</given-names></name></person-group>. <article-title>Evaluation of Miethke M.scio device implantation for intracranial pressure monitoring in patients with cerebrospinal fluid disorders</article-title>. <source>World Neurosurg</source>. (<year>2023</year>) <volume>179</volume>:<fpage>e63</fpage>&#x2013;<lpage>74</lpage>. <pub-id pub-id-type="doi">10.1016/j.wneu.2023.07.102</pub-id><pub-id pub-id-type="pmid">37506838</pub-id></citation></ref>
<ref id="B25"><label>25.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pennacchietti</surname><given-names>V</given-names></name><name><surname>Schaumann</surname><given-names>A</given-names></name><name><surname>Thomale</surname><given-names>UW</given-names></name></person-group>. <article-title>Maneuver protocol for outpatient telemetric intracranial pressure monitoring in hydrocephalus patients</article-title>. <source>Childs Nerv Syst</source>. (<year>2023</year>) <volume>39</volume>(<issue>1</issue>):<fpage>185</fpage>&#x2013;<lpage>95</lpage>. <pub-id pub-id-type="doi">10.1007/s00381-022-05659-5</pub-id><pub-id pub-id-type="pmid">36098768</pub-id></citation></ref>
<ref id="B26"><label>26.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Banks</surname><given-names>PDW</given-names></name><name><surname>Pandit</surname><given-names>AS</given-names></name><name><surname>Alradhawi</surname><given-names>M</given-names></name><name><surname>Aldabbagh</surname><given-names>Y</given-names></name><name><surname>Lee</surname><given-names>FMY</given-names></name><name><surname>Moncur</surname><given-names>EM</given-names></name><etal/></person-group> <article-title>The impact of telesensors on neurosurgical service demand: a cohort cost-effectiveness analysis from institutional and patient perspectives</article-title>. <source>Brain and Spine</source>. (<year>2022</year>) <volume>2</volume>:<fpage>101344</fpage>. <pub-id pub-id-type="doi">10.1016/j.bas.2022.101344</pub-id></citation></ref>
<ref id="B27"><label>27.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Korfias</surname><given-names>SI</given-names></name><name><surname>Banos</surname><given-names>S</given-names></name><name><surname>Alexoudi</surname><given-names>A</given-names></name><name><surname>Themistoklis</surname><given-names>K</given-names></name><name><surname>Vlachakis</surname><given-names>E</given-names></name><name><surname>Patrikelis</surname><given-names>P</given-names></name><etal/></person-group> <article-title>Telemetric intracranial pressure monitoring: our experience with 22 patients investigated for intracranial hypertension</article-title>. <source>Br J Neurosurg</source>. (<year>2021</year>) <volume>35</volume>(<issue>4</issue>):<fpage>430</fpage>&#x2013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1080/02688697.2020.1849544</pub-id><pub-id pub-id-type="pmid">33263434</pub-id></citation></ref>
<ref id="B28"><label>28.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Banks</surname><given-names>P</given-names></name><name><surname>Pandit</surname><given-names>A</given-names></name><name><surname>Toma</surname><given-names>A</given-names></name><name><surname>Thompson</surname><given-names>S</given-names></name><name><surname>Dub&#x00E9;-Fuller</surname><given-names>N</given-names></name><name><surname>Thorne</surname><given-names>L</given-names></name><etal/></person-group> <article-title>Happy-ICP: single-centre cohort of 184 telemetric intracranial pressure monitors</article-title>. <source>Brain Spine</source>. (<year>2021</year>) <volume>1</volume>:<fpage>100744</fpage>. <pub-id pub-id-type="doi">10.1016/j.bas.2021.100744</pub-id></citation></ref>
<ref id="B29"><label>29.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Khan</surname><given-names>M</given-names></name><name><surname>D&#x0027;Antona</surname><given-names>L</given-names></name><name><surname>De Gouveia</surname><given-names>M</given-names></name><name><surname>Pandit</surname><given-names>AS</given-names></name><name><surname>Mediratta</surname><given-names>S</given-names></name><name><surname>Craven</surname><given-names>CL</given-names></name><etal/></person-group> <article-title>Telemetric intracranial pressure monitoring after neuroendoscopic treatment of hydrocephalus: a valuable tool to recognise treatment failure</article-title>. <source>Brain Spine</source>. (<year>2021</year>) <volume>1</volume>:<fpage>100743</fpage>. <pub-id pub-id-type="doi">10.1016/j.bas.2021.100743</pub-id></citation></ref>
<ref id="B30"><label>30.</label><citation citation-type="book"><person-group person-group-type="author"><name><surname>Kommer</surname><given-names>M</given-names></name><name><surname>Boulton</surname><given-names>RG</given-names></name><name><surname>Loi</surname><given-names>L</given-names></name><name><surname>Robinson</surname><given-names>S</given-names></name><name><surname>Hawthorne</surname><given-names>C</given-names></name><name><surname>Shaw</surname><given-names>M</given-names></name><etal/></person-group> <article-title>Telemetric intracranial pressure: a snapshot does not give the full story</article-title>. In: <person-group person-group-type="editor"><name><surname>Depreitere</surname><given-names>B</given-names></name><name><surname>Meyfroidt</surname><given-names>G</given-names></name><name><surname>G&#x00FC;iza</surname><given-names>F</given-names></name></person-group>, editors. <source>Intracranial Pressure and Neuromonitoring XVII</source>. <publisher-loc>Cham</publisher-loc>: <publisher-name>Springer International Publishing</publisher-name> (<year>2021</year>). p. <fpage>323</fpage>&#x2013;<lpage>4</lpage>.</citation></ref>
<ref id="B31"><label>31.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Rot</surname><given-names>S</given-names></name><name><surname>Dweek</surname><given-names>M</given-names></name><name><surname>Gutowski</surname><given-names>P</given-names></name><name><surname>Goelz</surname><given-names>L</given-names></name><name><surname>Meier</surname><given-names>U</given-names></name><name><surname>Lemcke</surname><given-names>J</given-names></name></person-group>. <article-title>Comparative investigation of different telemetric methods for measuring intracranial pressure: a prospective pilot study</article-title>. <source>Fluids Barriers CNS</source>. (<year>2020</year>) <volume>17</volume>(<issue>1</issue>):<fpage>63</fpage>. <pub-id pub-id-type="doi">10.1186/s12987-020-00225-0</pub-id><pub-id pub-id-type="pmid">33069242</pub-id></citation></ref>
<ref id="B32"><label>32.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pennacchietti</surname><given-names>V</given-names></name><name><surname>Prinz</surname><given-names>V</given-names></name><name><surname>Schaumann</surname><given-names>A</given-names></name><name><surname>Finger</surname><given-names>T</given-names></name><name><surname>Schulz</surname><given-names>M</given-names></name><name><surname>Thomale</surname><given-names>UW</given-names></name></person-group>. <article-title>Single center experiences with telemetric intracranial pressure measurements in patients with CSF circulation disturbances</article-title>. <source>Acta Neurochir (Wien)</source>. (<year>2020</year>) <volume>162</volume>(<issue>10</issue>):<fpage>2487</fpage>&#x2013;<lpage>97</lpage>. <pub-id pub-id-type="doi">10.1007/s00701-020-04421-7</pub-id><pub-id pub-id-type="pmid">32495080</pub-id></citation></ref>
<ref id="B33"><label>33.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pedersen</surname><given-names>SH</given-names></name><name><surname>Norager</surname><given-names>NH</given-names></name><name><surname>Lilja-Cyron</surname><given-names>A</given-names></name><name><surname>Juhler</surname><given-names>M</given-names></name></person-group>. <article-title>Telemetric intracranial pressure monitoring in children</article-title>. <source>Childs Nerv Syst</source>. (<year>2020</year>) <volume>36</volume>(<issue>1</issue>):<fpage>49</fpage>&#x2013;<lpage>58</lpage>. <pub-id pub-id-type="doi">10.1007/s00381-019-04271-4</pub-id><pub-id pub-id-type="pmid">31309286</pub-id></citation></ref>
<ref id="B34"><label>34.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>M&#x00FC;ller</surname><given-names>SJ</given-names></name><name><surname>Freimann</surname><given-names>FB</given-names></name><name><surname>von der Brelie</surname><given-names>C</given-names></name><name><surname>Rohde</surname><given-names>V</given-names></name><name><surname>Schatlo</surname><given-names>B</given-names></name></person-group>. <article-title>Test-retest reliability of outpatient telemetric intracranial pressure measurements in shunt-dependent patients with hydrocephalus and idiopathic intracranial hypertension</article-title>. <source>World Neurosurg</source>. (<year>2019</year>) <volume>131</volume>:<fpage>e74</fpage>&#x2013;<lpage>80</lpage>. <pub-id pub-id-type="doi">10.1016/j.wneu.2019.07.014</pub-id></citation></ref>
<ref id="B35"><label>35.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Norager</surname><given-names>NH</given-names></name><name><surname>Lilja-Cyron</surname><given-names>A</given-names></name><name><surname>Hansen</surname><given-names>TS</given-names></name><name><surname>Juhler</surname><given-names>M</given-names></name></person-group>. <article-title>Deciding on appropriate telemetric intracranial pressure monitoring system</article-title>. <source>World Neurosurg</source>. (<year>2019</year>) <volume>126</volume>:<fpage>564</fpage>&#x2013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1016/j.wneu.2019.03.077</pub-id><pub-id pub-id-type="pmid">30898734</pub-id></citation></ref>
<ref id="B36"><label>36.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tschan</surname><given-names>CA</given-names></name><name><surname>Velazquez Sanchez</surname><given-names>VF</given-names></name><name><surname>Heckelmann</surname><given-names>M</given-names></name><name><surname>Antes</surname><given-names>S</given-names></name></person-group>. <article-title>Home telemonitoring of intracranial pressure</article-title>. <source>Acta Neurochir (Wien)</source>. (<year>2019</year>) <volume>161</volume>(<issue>8</issue>):<fpage>1605</fpage>&#x2013;<lpage>17</lpage>. <pub-id pub-id-type="doi">10.1007/s00701-019-03959-5</pub-id><pub-id pub-id-type="pmid">31168730</pub-id></citation></ref>
<ref id="B37"><label>37.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Norager</surname><given-names>NH</given-names></name><name><surname>Lilja-Cyron</surname><given-names>A</given-names></name><name><surname>Bjarkam</surname><given-names>CR</given-names></name><name><surname>Duus</surname><given-names>S</given-names></name><name><surname>Juhler</surname><given-names>M</given-names></name></person-group>. <article-title>Telemetry in intracranial pressure monitoring: sensor survival and drift</article-title>. <source>Acta Neurochir (Wien)</source>. (<year>2018</year>) <volume>160</volume>(<issue>11</issue>):<fpage>2137</fpage>&#x2013;<lpage>44</lpage>. <pub-id pub-id-type="doi">10.1007/s00701-018-3691-9</pub-id><pub-id pub-id-type="pmid">30267207</pub-id></citation></ref>
<ref id="B38"><label>38.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Antes</surname><given-names>S</given-names></name><name><surname>Stadie</surname><given-names>A</given-names></name><name><surname>M&#x00FC;ller</surname><given-names>S</given-names></name><name><surname>Linsler</surname><given-names>S</given-names></name><name><surname>Breuskin</surname><given-names>D</given-names></name><name><surname>Oertel</surname><given-names>J</given-names></name></person-group>. <article-title>Intracranial pressure-guided shunt valve adjustments with the Miethke Sensor Reservoir</article-title>. <source>World Neurosurg</source>. (<year>2018</year>) <volume>109</volume>:<fpage>e642</fpage>&#x2013;<lpage>e50</lpage>. <pub-id pub-id-type="doi">10.1016/j.wneu.2017.10.044</pub-id><pub-id pub-id-type="pmid">29054776</pub-id></citation></ref>
<ref id="B39"><label>39.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Thompson</surname><given-names>S</given-names></name><name><surname>D&#x0027;Antona</surname><given-names>L</given-names></name><name><surname>Thorne</surname><given-names>L</given-names></name><name><surname>Toma</surname><given-names>A</given-names></name><name><surname>Watkins</surname><given-names>L</given-names></name></person-group>. <article-title>Cost versus benefit analysis of telemetric ICP measuring device within a shunt system: a single centre experience</article-title>. <source>Fluids Barriers CNS</source>. (<year>2018</year>) <volume>15</volume>(<issue>Suppl 1</issue>):<fpage>45</fpage>.</citation></ref>
<ref id="B40"><label>40.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Thompson</surname><given-names>S</given-names></name><name><surname>D&#x0027;Antona</surname><given-names>L</given-names></name><name><surname>Thorne</surname><given-names>L</given-names></name><name><surname>Toma</surname><given-names>A</given-names></name><name><surname>Watkins</surname><given-names>L</given-names></name></person-group>. <article-title>A new implantable telemetric intracranial pressure monitoring device within a shunt system: a single centre experience of 60 implanted units over a 6.5 year period</article-title>. <source>Fluids Barriers CNS</source>. (<year>2018</year>) <volume>15</volume>(<issue>Suppl 1</issue>):<fpage>46</fpage>.</citation></ref>
<ref id="B41"><label>41.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ertl</surname><given-names>P</given-names></name><name><surname>Hermann</surname><given-names>EJ</given-names></name><name><surname>Heissler</surname><given-names>HE</given-names></name><name><surname>Krauss</surname><given-names>JK</given-names></name></person-group>. <article-title>Telemetric intracranial pressure recording via a shunt system integrated sensor: a safety and feasibility study</article-title>. <source>J Neurol Surg A Cent Eur Neurosurg</source>. (<year>2017</year>) <volume>78</volume>(<issue>6</issue>):<fpage>572</fpage>&#x2013;<lpage>5</lpage>. <pub-id pub-id-type="doi">10.1055/s-0037-1603632</pub-id><pub-id pub-id-type="pmid">28586937</pub-id></citation></ref>
<ref id="B42"><label>42.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Barber</surname><given-names>JM</given-names></name><name><surname>Pringle</surname><given-names>CJ</given-names></name><name><surname>Raffalli-Ebezant</surname><given-names>H</given-names></name><name><surname>Pathmanaban</surname><given-names>O</given-names></name><name><surname>Ramirez</surname><given-names>R</given-names></name><name><surname>Kamaly-Asl</surname><given-names>ID</given-names></name></person-group>. <article-title>Telemetric intra-cranial pressure monitoring: clinical and financial considerations</article-title>. <source>Br J Neurosurg</source>. (<year>2017</year>) <volume>31</volume>(<issue>3</issue>):<fpage>300</fpage>&#x2013;<lpage>6</lpage>. <pub-id pub-id-type="doi">10.1080/02688697.2016.1229752</pub-id><pub-id pub-id-type="pmid">27644335</pub-id></citation></ref>
<ref id="B43"><label>43.</label><citation citation-type="book"><person-group person-group-type="author"><name><surname>Andresen</surname><given-names>M</given-names></name><name><surname>Hadi</surname><given-names>A</given-names></name><name><surname>Juhler</surname><given-names>M</given-names></name></person-group>. <article-title>Evaluation of intracranial pressure in different body postures and disease entities</article-title>. In: <person-group person-group-type="editor"><name><surname>Ang</surname><given-names>B-T</given-names></name></person-group>, editor. <source>Intracranial Pressure and Brain Monitoring XV</source>. <publisher-loc>Cham</publisher-loc>: <publisher-name>Springer International Publishing</publisher-name> (<year>2016</year>). p. <fpage>45</fpage>&#x2013;<lpage>7</lpage>.</citation></ref>
<ref id="B44"><label>44.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Maeske</surname><given-names>M</given-names></name><name><surname>Mayer</surname><given-names>S</given-names></name><name><surname>Blanc</surname><given-names>SM</given-names></name><name><surname>Schulz</surname><given-names>C</given-names></name><name><surname>Kunz</surname><given-names>U</given-names></name><name><surname>Mauer</surname><given-names>UM</given-names></name></person-group>. <article-title>Telemetric intracranial pressure measurement: a graphical approach to data analysis</article-title>. <source>J Neurol Surg A Cent Eur Neurosurg</source>. (<year>2016</year>) <volume>77</volume>(<issue>3</issue>):<fpage>258</fpage>&#x2013;<lpage>63</lpage>. <pub-id pub-id-type="doi">10.1055/s-0035-1566117</pub-id><pub-id pub-id-type="pmid">26588254</pub-id></citation></ref>
<ref id="B45"><label>45.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Farahmand</surname><given-names>D</given-names></name><name><surname>Qvarlander</surname><given-names>S</given-names></name><name><surname>Malm</surname><given-names>J</given-names></name><name><surname>Wikkels&#x00F6;</surname><given-names>C</given-names></name><name><surname>Eklund</surname><given-names>A</given-names></name><name><surname>Tisell</surname><given-names>M</given-names></name></person-group>. <article-title>Intracranial pressure in hydrocephalus: impact of shunt adjustments and body positions</article-title>. <source>J Neurol Neurosurg Psychiatry</source>. (<year>2015</year>) <volume>86</volume>(<issue>2</issue>):<fpage>222</fpage>&#x2013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1136/jnnp-2014-307873</pub-id><pub-id pub-id-type="pmid">24963125</pub-id></citation></ref>
<ref id="B46"><label>46.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Raffalli-Ebezant</surname><given-names>H</given-names></name><name><surname>Barber</surname><given-names>JM</given-names></name><name><surname>Ramirez</surname><given-names>R</given-names></name><name><surname>Kamal</surname><given-names>MA</given-names></name></person-group>. <article-title>42nd Annual Meeting of the International Society for Pediatric Neurosurgery, Rio De Janeiro, Brazil, Nov 9&#x2013;13, 2014</article-title>. <source>Child&#x2019;s Nervous System</source>. (<year>2014</year>) <volume>30</volume>(<issue>11</issue>):<fpage>1913</fpage>&#x2013;<lpage>95</lpage>. <pub-id pub-id-type="doi">10.1007/s00381-014-2524-2</pub-id></citation></ref>
<ref id="B47"><label>47.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Andresen</surname><given-names>M</given-names></name><name><surname>Hadi</surname><given-names>A</given-names></name><name><surname>Petersen</surname><given-names>LG</given-names></name><name><surname>Juhler</surname><given-names>M</given-names></name></person-group>. <article-title>Effect of postural changes on ICP in healthy and ill subjects</article-title>. <source>Acta Neurochir (Wien)</source>. (<year>2015</year>) <volume>157</volume>(<issue>1</issue>):<fpage>109</fpage>&#x2013;<lpage>13</lpage>. <pub-id pub-id-type="doi">10.1007/s00701-014-2250-2</pub-id><pub-id pub-id-type="pmid">25307778</pub-id></citation></ref>
<ref id="B48"><label>48.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Antes</surname><given-names>S</given-names></name><name><surname>Tschan</surname><given-names>CA</given-names></name><name><surname>Oertel</surname><given-names>JM</given-names></name></person-group>. <article-title>An operative technique combining endoscopic third ventriculostomy and long-term ICP monitoring</article-title>. <source>Childs Nerv Syst</source>. (<year>2014</year>) <volume>30</volume>(<issue>2</issue>):<fpage>331</fpage>&#x2013;<lpage>5</lpage>. <pub-id pub-id-type="doi">10.1007/s00381-013-2269-3</pub-id><pub-id pub-id-type="pmid">23989429</pub-id></citation></ref>
<ref id="B49"><label>49.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lilja</surname><given-names>A</given-names></name><name><surname>Andresen</surname><given-names>M</given-names></name><name><surname>Hadi</surname><given-names>A</given-names></name><name><surname>Christoffersen</surname><given-names>D</given-names></name><name><surname>Juhler</surname><given-names>M</given-names></name></person-group>. <article-title>Clinical experience with telemetric intracranial pressure monitoring in a Danish neurosurgical center</article-title>. <source>Clin Neurol Neurosurg</source>. (<year>2014</year>) <volume>120</volume>:<fpage>36</fpage>&#x2013;<lpage>40</lpage>. <pub-id pub-id-type="doi">10.1016/j.clineuro.2014.02.010</pub-id><pub-id pub-id-type="pmid">24731573</pub-id></citation></ref>
<ref id="B50"><label>50.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Freimann</surname><given-names>FB</given-names></name><name><surname>Schulz</surname><given-names>M</given-names></name><name><surname>Haberl</surname><given-names>H</given-names></name><name><surname>Thomale</surname><given-names>UW</given-names></name></person-group>. <article-title>Feasibility of telemetric ICP-guided valve adjustments for complex shunt therapy</article-title>. <source>Childs Nerv Syst</source>. (<year>2014</year>) <volume>30</volume>(<issue>4</issue>):<fpage>689</fpage>&#x2013;<lpage>97</lpage>. <pub-id pub-id-type="doi">10.1007/s00381-013-2324-0</pub-id><pub-id pub-id-type="pmid">24264382</pub-id></citation></ref>
<ref id="B51"><label>51.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Antes</surname><given-names>S</given-names></name><name><surname>Tschan</surname><given-names>CA</given-names></name><name><surname>Kunze</surname><given-names>G</given-names></name><name><surname>Ewert</surname><given-names>L</given-names></name><name><surname>Zimmer</surname><given-names>A</given-names></name><name><surname>Halfmann</surname><given-names>A</given-names></name><etal/></person-group> <article-title>Clinical and radiological findings in long-term intracranial pressure monitoring</article-title>. <source>Acta Neurochir (Wien)</source>. (<year>2014</year>) <volume>156</volume>(<issue>5</issue>):<fpage>1009</fpage>&#x2013;<lpage>19</lpage>. <pub-id pub-id-type="doi">10.1007/s00701-013-1991-7</pub-id><pub-id pub-id-type="pmid">24493000</pub-id></citation></ref>
<ref id="B52"><label>52.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tschan</surname><given-names>CA</given-names></name><name><surname>Antes</surname><given-names>S</given-names></name><name><surname>Wagner</surname><given-names>W</given-names></name><name><surname>Oertel</surname><given-names>J</given-names></name></person-group>. <article-title>Abstracts of the 41st Annual Meeting of the International Society for Pediatric Neurosurgery, Sept 29&#x2013;Oct 3, 2013, Mainz, Germany</article-title>. <source>Childs Nerv Syst</source>. (<year>2013</year>) <volume>29</volume>(<issue>9</issue>):<fpage>1689</fpage>&#x2013;<lpage>784</lpage>. <pub-id pub-id-type="doi">10.1007/s00381-013-2261-y</pub-id><pub-id pub-id-type="pmid">24013339</pub-id></citation></ref>
<ref id="B53"><label>53.</label><citation citation-type="confproc"><person-group person-group-type="author"><name><surname>Elixmann</surname><given-names>IM</given-names></name><name><surname>Goffin</surname><given-names>C</given-names></name><name><surname>Krueger</surname><given-names>R</given-names></name><name><surname>Meier</surname><given-names>U</given-names></name><name><surname>Lemcke</surname><given-names>J</given-names></name><name><surname>Kiefer</surname><given-names>M</given-names></name><etal/></person-group> <article-title>Case study of relevant pressures for an implanted hydrocephalus valve in everyday life</article-title>. <conf-name>2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society</conf-name> (<year>2012</year>).</citation></ref>
<ref id="B54"><label>54.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Welschehold</surname><given-names>S</given-names></name><name><surname>Schmalhausen</surname><given-names>E</given-names></name><name><surname>Dodier</surname><given-names>P</given-names></name><name><surname>Vulcu</surname><given-names>S</given-names></name><name><surname>Oertel</surname><given-names>J</given-names></name><name><surname>Wagner</surname><given-names>W</given-names></name><etal/></person-group> <article-title>First clinical results with a new telemetric intracranial pressure-monitoring system</article-title>. <source>Neurosurgery</source>. (<year>2012</year>) <volume>70</volume>(<issue>1 Suppl Operative</issue>):<fpage>44</fpage>&#x2013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1227/NEU.0b013e31822dda12</pub-id><pub-id pub-id-type="pmid">21772222</pub-id></citation></ref>
<ref id="B55"><label>55.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tschan</surname><given-names>CA</given-names></name><name><surname>Dodier</surname><given-names>P</given-names></name><name><surname>Vulcu</surname><given-names>S</given-names></name><name><surname>Oertel</surname><given-names>J</given-names></name><name><surname>Wagner</surname><given-names>W</given-names></name></person-group>. <article-title>39th Annual Meeting of the International Society for Pediatric Neurosurgery, Goa, India, October 16-20, 2011</article-title>. <source>Child&#x2019;s Nervous System</source>. (<year>2011</year>) <volume>27</volume>(<issue>10</issue>):<fpage>1751</fpage>&#x2013;<lpage>850</lpage>. <pub-id pub-id-type="doi">10.1007/s00381-011-1524-8</pub-id></citation></ref>
<ref id="B56"><label>56.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Frim</surname><given-names>DM</given-names></name><name><surname>Lathrop</surname><given-names>D</given-names></name></person-group>. <article-title>Telemetric assessment of intracranial pressure changes consequent to manipulations of the Codman-Medos programmable shunt valve</article-title>. <source>Pediatr Neurosurg</source>. (<year>2000</year>) <volume>33</volume>(<issue>5</issue>):<fpage>237</fpage>&#x2013;<lpage>42</lpage>. <pub-id pub-id-type="doi">10.1159/000055961</pub-id><pub-id pub-id-type="pmid">11155059</pub-id></citation></ref>
<ref id="B57"><label>57.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Frim</surname><given-names>DM</given-names></name><name><surname>Goumnerova</surname><given-names>LC</given-names></name></person-group>. <article-title><italic>In vivo</italic> intracranial pressure dynamics in patients with hydrocephalus treated by shunt placement</article-title>. <source>J Neurosurg</source>. (<year>2000</year>) <volume>92</volume>(<issue>6</issue>):<fpage>927</fpage>&#x2013;<lpage>32</lpage>. <pub-id pub-id-type="doi">10.3171/jns.2000.92.6.0927</pub-id><pub-id pub-id-type="pmid">10839251</pub-id></citation></ref>
<ref id="B58"><label>58.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Richard</surname><given-names>KE</given-names></name><name><surname>Block</surname><given-names>FR</given-names></name><name><surname>Weiser</surname><given-names>RR</given-names></name></person-group>. <article-title>First clinical results with a telemetric shunt-integrated ICP-sensor</article-title>. <source>Neurol Res</source>. (<year>1999</year>) <volume>21</volume>(<issue>1</issue>):<fpage>117</fpage>&#x2013;<lpage>20</lpage>. <pub-id pub-id-type="doi">10.1080/01616412.1999.11740906</pub-id><pub-id pub-id-type="pmid">10048069</pub-id></citation></ref>
<ref id="B59"><label>59.</label><citation citation-type="book"><person-group person-group-type="author"><name><surname>Wayenberg</surname><given-names>J-L</given-names></name></person-group>. <article-title>Non-invasive measurement of intracranial pressure in neonates and infants: experience with the Rotterdam Teletransducer</article-title>. In: <person-group person-group-type="editor"><name><surname>Marmarou</surname><given-names>A</given-names></name><name><surname>Bullock</surname><given-names>R</given-names></name><name><surname>Avezaat</surname><given-names>C</given-names></name><name><surname>Baethmann</surname><given-names>A</given-names></name><name><surname>Becker</surname><given-names>D</given-names></name><name><surname>Brock</surname><given-names>M</given-names></name><etal/></person-group> editors. <source>Intracranial Pressure and Neuromonitoring in Brain Injury</source>. <publisher-loc>Vienna</publisher-loc>: <publisher-name>Springer Vienna</publisher-name> (<year>1998</year>). p. <fpage>70</fpage>&#x2013;<lpage>3</lpage>.</citation></ref>
<ref id="B60"><label>60.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Munshi</surname><given-names>I</given-names></name><name><surname>Lathrop</surname><given-names>D</given-names></name><name><surname>Madsen</surname><given-names>JR</given-names></name><name><surname>Frim</surname><given-names>DM</given-names></name></person-group>. <article-title>Intraventricular pressure dynamics in patients with ventriculopleural shunts: a telemetric study</article-title>. <source>Pediatr Neurosurg</source>. (<year>1998</year>) <volume>28</volume>(<issue>2</issue>):<fpage>67</fpage>&#x2013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1159/000028623</pub-id><pub-id pub-id-type="pmid">9693334</pub-id></citation></ref>
<ref id="B61"><label>61.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Frim</surname><given-names>DM</given-names></name><name><surname>Goumnerova</surname><given-names>LC</given-names></name></person-group>. <article-title>Telemetric intraventricular pressure measurements after third ventriculocisternostomy in a patient with noncommunicating hydrocephalus</article-title>. <source>Neurosurgery</source>. (<year>1997</year>) <volume>41</volume>(<issue>6</issue>):<fpage>1425</fpage>&#x2013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1097/00006123-199712000-00044</pub-id><pub-id pub-id-type="pmid">9402598</pub-id></citation></ref>
<ref id="B62"><label>62.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wayenberg</surname><given-names>JL</given-names></name><name><surname>Vermeylen</surname><given-names>D</given-names></name><name><surname>Raftopoulos</surname><given-names>C</given-names></name><name><surname>Detemmerman</surname><given-names>D</given-names></name><name><surname>M&#x00FC;ller</surname><given-names>MF</given-names></name><name><surname>Pardou</surname><given-names>A</given-names></name></person-group>. <article-title>Monitoring of fontanelle pressure in neonates and infants. Evaluation of a new measuring technique, determination of normal values and clinical usefulness</article-title>. <source>Rev Med Brux</source>. (<year>1993</year>) <volume>14</volume>(<issue>7</issue>):<fpage>209</fpage>&#x2013;<lpage>15</lpage>.<pub-id pub-id-type="pmid">8235185</pub-id></citation></ref>
<ref id="B63"><label>63.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kamiryo</surname><given-names>T</given-names></name><name><surname>Fujii</surname><given-names>Y</given-names></name><name><surname>Kusaka</surname><given-names>M</given-names></name><name><surname>Kashiwagi</surname><given-names>S</given-names></name><name><surname>Ito</surname><given-names>H</given-names></name></person-group>. <article-title>Intracranial pressure monitoring using a programmable pressure valve and a telemetric intracranial pressure sensor in a case of slit ventricle syndrome after multiple shunt revisions</article-title>. <source>Childs Nerv Syst</source>. (<year>1991</year>) <volume>7</volume>(<issue>4</issue>):<fpage>233</fpage>&#x2013;<lpage>4</lpage>. <pub-id pub-id-type="doi">10.1007/bf00249403</pub-id><pub-id pub-id-type="pmid">1933922</pub-id></citation></ref>
<ref id="B64"><label>64.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yamaguchi</surname><given-names>Y</given-names></name><name><surname>Yamaguchi</surname><given-names>T</given-names></name><name><surname>Yanaki</surname><given-names>T</given-names></name><name><surname>Masuzawa</surname><given-names>T</given-names></name></person-group>. <article-title>The changes of intracranial pressure after shunt surgery: measurements of pre- and postshunt ventricular fluid pressure with an implanted telemetric ICP sensor</article-title>. <source>No Shinkei Geka</source>. (<year>1990</year>) <volume>18</volume>(<issue>2</issue>):<fpage>175</fpage>&#x2013;<lpage>82</lpage>.<pub-id pub-id-type="pmid">2336146</pub-id></citation></ref>
<ref id="B65"><label>65.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chapman</surname><given-names>PH</given-names></name><name><surname>Cosman</surname><given-names>ER</given-names></name><name><surname>Arnold</surname><given-names>MA</given-names></name></person-group>. <article-title>The relationship between ventricular fluid pressure and body position in normal subjects and subjects with shunts: a telemetric study</article-title>. <source>Neurosurgery</source>. (<year>1990</year>) <volume>26</volume>(<issue>2</issue>):<fpage>181</fpage>&#x2013;<lpage>89</lpage>. <pub-id pub-id-type="doi">10.1227/00006123-199002000-00001</pub-id><pub-id pub-id-type="pmid">2308665</pub-id></citation></ref>
<ref id="B66"><label>66.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>G&#x00FC;&#x00E7;er</surname><given-names>G</given-names></name><name><surname>Viernstein</surname><given-names>L</given-names></name><name><surname>Wang</surname><given-names>A</given-names></name><name><surname>Szymanski</surname><given-names>R</given-names></name></person-group>. <article-title>Ten-year follow-up on the performance of a telemetric intracranial pressure sensor</article-title>. <source>Neurosurgery</source>. (<year>1988</year>) <volume>22</volume>(<issue>5</issue>):<fpage>892</fpage>&#x2013;<lpage>5</lpage>. <pub-id pub-id-type="doi">10.1227/00006123-198805000-00014</pub-id></citation></ref>
<ref id="B67"><label>67.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Maas</surname><given-names>AI</given-names></name><name><surname>de Jong</surname><given-names>DA</given-names></name></person-group>. <article-title>The Rotterdam Teletransducer: state of the device</article-title>. <source>Acta Neurochir (Wien)</source>. (<year>1986</year>) <volume>79</volume>(<issue>1</issue>):<fpage>5</fpage>&#x2013;<lpage>12</lpage>. <pub-id pub-id-type="doi">10.1007/bf01403460</pub-id><pub-id pub-id-type="pmid">3953325</pub-id></citation></ref>
<ref id="B68"><label>68.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Nulsen</surname><given-names>FE</given-names></name><name><surname>Leung</surname><given-names>A</given-names></name><name><surname>Fleming</surname><given-names>DG</given-names></name><name><surname>Lorig</surname><given-names>RJ</given-names></name><name><surname>Bettice</surname><given-names>JA</given-names></name><name><surname>Donlin</surname><given-names>KA</given-names></name><etal/></person-group> <article-title>Chronic intracranial pressure monitoring by telemetry: clinical experience</article-title>. <source>Ann Biomed Eng</source>. (<year>1980</year>) <volume>8</volume>(<issue>4-6</issue>):<fpage>505</fpage>&#x2013;<lpage>13</lpage>. <pub-id pub-id-type="doi">10.1007/BF02363449</pub-id><pub-id pub-id-type="pmid">7294462</pub-id></citation></ref>
<ref id="B69"><label>69.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chapman</surname><given-names>PH</given-names></name><name><surname>Cosman</surname><given-names>E</given-names></name><name><surname>Arnold</surname><given-names>M</given-names></name></person-group>. <article-title>Telemetric ICP monitoring after surgery for posterior fossa and third ventricular tumors. Technical note</article-title>. <source>J Neurosurg</source>. (<year>1984</year>) <volume>60</volume>(<issue>3</issue>):<fpage>649</fpage>&#x2013;<lpage>51</lpage>. <pub-id pub-id-type="doi">10.3171/jns.1984.60.3.0649</pub-id><pub-id pub-id-type="pmid">6699717</pub-id></citation></ref>
<ref id="B70"><label>70.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Longatti</surname><given-names>PL</given-names></name><name><surname>Carteri</surname><given-names>A</given-names></name></person-group>. <article-title>Active singling out of shunt independence</article-title>. <source>Childs Nerv Syst</source>. (<year>1994</year>) <volume>10</volume>(<issue>5</issue>):<fpage>334</fpage>&#x2013;<lpage>6</lpage>. <pub-id pub-id-type="doi">10.1007/BF00335173</pub-id><pub-id pub-id-type="pmid">7954503</pub-id></citation></ref>
<ref id="B71"><label>71.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Miyake</surname><given-names>H</given-names></name><name><surname>Ohta</surname><given-names>T</given-names></name><name><surname>Kajimoto</surname><given-names>Y</given-names></name><name><surname>Matsukawa</surname><given-names>M</given-names></name></person-group>. <article-title>A new ventriculoperitoneal shunt with a telemetric intracranial pressure sensor: clinical experience in 94 patients with hydrocephalus</article-title>. <source>Neurosurgery</source>. (<year>1997</year>) <volume>40</volume>(<issue>5</issue>):<fpage>931</fpage>&#x2013;<lpage>5</lpage>. <pub-id pub-id-type="doi">10.1097/00006123-199705000-00009</pub-id><pub-id pub-id-type="pmid">9149250</pub-id></citation></ref>
<ref id="B72"><label>72.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gok</surname><given-names>H</given-names></name><name><surname>Celik</surname><given-names>SE</given-names></name><name><surname>Yangi</surname><given-names>K</given-names></name><name><surname>Yavuz</surname><given-names>AY</given-names></name><name><surname>Percinoglu</surname><given-names>G</given-names></name><name><surname>Unlu</surname><given-names>NU</given-names></name><etal/></person-group> <article-title>Management of epidural hematomas in pediatric and adult population: a hospital-based retrospective study</article-title>. <source>World Neurosurg</source>. (<year>2023</year>) <volume>177</volume>:<fpage>e686</fpage>&#x2013;<lpage>e92</lpage>. <pub-id pub-id-type="doi">10.1016/j.wneu.2023.06.123</pub-id><pub-id pub-id-type="pmid">37406801</pub-id></citation></ref>
<ref id="B73"><label>73.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yangi</surname><given-names>K</given-names></name><name><surname>Demir</surname><given-names>DD</given-names></name><name><surname>Uzunkol</surname><given-names>A</given-names></name></person-group>. <article-title>Intracranial hemorrhage after Pfizer-BioNTech (BNT162b2) mRNA COVID-19 vaccination: a case report</article-title>. <source>Cureus</source>. (<year>2023</year>) <volume>15</volume>(<issue>4</issue>):<fpage>e37747</fpage>. <pub-id pub-id-type="doi">10.7759/cureus.37747</pub-id><pub-id pub-id-type="pmid">37214039</pub-id></citation></ref>
<ref id="B74"><label>74.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zoerle</surname><given-names>T</given-names></name><name><surname>Lombardo</surname><given-names>A</given-names></name><name><surname>Colombo</surname><given-names>A</given-names></name><name><surname>Longhi</surname><given-names>L</given-names></name><name><surname>Zanier</surname><given-names>ER</given-names></name><name><surname>Rampini</surname><given-names>P</given-names></name><etal/></person-group> <article-title>Intracranial pressure after subarachnoid hemorrhage</article-title>. <source>Crit Care Med</source>. (<year>2015</year>) <volume>43</volume>(<issue>1</issue>):<fpage>168</fpage>&#x2013;<lpage>76</lpage>. <pub-id pub-id-type="doi">10.1097/ccm.0000000000000670</pub-id><pub-id pub-id-type="pmid">25318385</pub-id></citation></ref>
<ref id="B75"><label>75.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yangi</surname><given-names>K</given-names></name><name><surname>Yavuz</surname><given-names>AY</given-names></name><name><surname>Percinoglu</surname><given-names>G</given-names></name><name><surname>Aki</surname><given-names>B</given-names></name><name><surname>Celik</surname><given-names>SE</given-names></name></person-group>. <article-title>A huge calcified supratentorial ependymoma: a case report</article-title>. <source>Cureus</source>. (<year>2023</year>) <volume>15</volume>(<issue>4</issue>):<fpage>e37493</fpage>. <pub-id pub-id-type="doi">10.7759/cureus.37493</pub-id><pub-id pub-id-type="pmid">37064720</pub-id></citation></ref>
<ref id="B76"><label>76.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bothwell</surname><given-names>SW</given-names></name><name><surname>Janigro</surname><given-names>D</given-names></name><name><surname>Patabendige</surname><given-names>A</given-names></name></person-group>. <article-title>Cerebrospinal fluid dynamics and intracranial pressure elevation in neurological diseases</article-title>. <source>Fluids Barriers CNS</source>. (<year>2019</year>) <volume>16</volume>(<issue>1</issue>):<fpage>9</fpage>. <pub-id pub-id-type="doi">10.1186/s12987-019-0129-6</pub-id><pub-id pub-id-type="pmid">30967147</pub-id></citation></ref>
<ref id="B77"><label>77.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Khan</surname><given-names>F</given-names></name><name><surname>Singhal</surname><given-names>P</given-names></name><name><surname>Agrawal</surname><given-names>SS</given-names></name><name><surname>Yangi</surname><given-names>K</given-names></name><name><surname>Bozkurt</surname><given-names>I</given-names></name><name><surname>Chaurasia</surname><given-names>B</given-names></name></person-group>. <article-title>Surgical management of giant suprasellar craniopharyngioma in a 3-year-old: case report with a review of the literature</article-title>. <source>Surg Case Rep</source>. (<year>2025</year>) <volume>5</volume>:<fpage>100121</fpage>. <pub-id pub-id-type="doi">10.1016/j.sycrs.2025.100121</pub-id></citation></ref>
<ref id="B78"><label>78.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kumar</surname><given-names>R</given-names></name><name><surname>Singhi</surname><given-names>S</given-names></name><name><surname>Singhi</surname><given-names>P</given-names></name><name><surname>Jayashree</surname><given-names>M</given-names></name><name><surname>Bansal</surname><given-names>A</given-names></name><name><surname>Bhatti</surname><given-names>A</given-names></name></person-group>. <article-title>Randomized controlled trial comparing cerebral perfusion pressure-targeted therapy versus intracranial pressure-targeted therapy for raised intracranial pressure due to acute CNS infections in children</article-title>. <source>Crit Care Med</source>. (<year>2014</year>) <volume>42</volume>(<issue>8</issue>):<fpage>1775</fpage>&#x2013;<lpage>87</lpage>. <pub-id pub-id-type="doi">10.1097/ccm.0000000000000298</pub-id><pub-id pub-id-type="pmid">24690571</pub-id></citation></ref>
<ref id="B79"><label>79.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Freimann</surname><given-names>FB</given-names></name><name><surname>Sprung</surname><given-names>C</given-names></name><name><surname>Chopra</surname><given-names>SS</given-names></name><name><surname>Vajkoczy</surname><given-names>P</given-names></name><name><surname>Wolf</surname><given-names>S</given-names></name></person-group>. <article-title>Large-scale referencing of the telemetric Neurovent-P-tel intracranial pressure sensor in a porcine model</article-title>. <source>Pediatr Neurosurg</source>. (<year>2013</year>) <volume>49</volume>(<issue>1</issue>):<fpage>29</fpage>&#x2013;<lpage>32</lpage>. <pub-id pub-id-type="doi">10.1159/000355561</pub-id><pub-id pub-id-type="pmid">24192757</pub-id></citation></ref>
<ref id="B80"><label>80.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Cosman</surname><given-names>ER</given-names></name><name><surname>Zervas</surname><given-names>NT</given-names></name><name><surname>Chapman</surname><given-names>PH</given-names></name><name><surname>Cosman</surname><given-names>BJ</given-names></name><name><surname>Arnold</surname><given-names>MA</given-names></name></person-group>. <article-title>A telemetric pressure sensor for ventricular shunt systems</article-title>. <source>Surg Neurol</source>. (<year>1979</year>) <volume>11</volume>(<issue>4</issue>):<fpage>287</fpage>&#x2013;<lpage>94</lpage>.<pub-id pub-id-type="pmid">441915</pub-id></citation></ref>
<ref id="B81"><label>81.</label><citation citation-type="book"><person-group person-group-type="author"><name><surname>Rekate</surname><given-names>H</given-names></name><name><surname>Fleming</surname><given-names>D</given-names></name><name><surname>Leung</surname><given-names>A</given-names></name><name><surname>Ko</surname><given-names>W</given-names></name><name><surname>Nulsen</surname><given-names>F</given-names></name></person-group>. <source>Chronic Monitoring of Intraventricular Pressure in Children Using Telemetry: Engineering and Physiologic Aspects</source>. <publisher-loc>New York</publisher-loc>: <publisher-name>Springer</publisher-name> (<year>1983</year>). p. <fpage>127</fpage>&#x2013;<lpage>30</lpage>.</citation></ref>
<ref id="B82"><label>82.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Leung</surname><given-names>AM</given-names></name><name><surname>Ko</surname><given-names>WH</given-names></name><name><surname>Spear</surname><given-names>TM</given-names></name><name><surname>Bettice</surname><given-names>JA</given-names></name></person-group>. <article-title>Intracranial pressure telemetry system using semicustom integrated circuits</article-title>. <source>IEEE Trans Biomed Eng</source>. (<year>1986</year>) <volume>33</volume>(<issue>4</issue>):<fpage>386</fpage>&#x2013;<lpage>95</lpage>. <pub-id pub-id-type="doi">10.1109/TBME.1986.325794</pub-id><pub-id pub-id-type="pmid">3957394</pub-id></citation></ref>
<ref id="B83"><label>83.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ko</surname><given-names>WH</given-names></name><name><surname>Meyrick</surname><given-names>CW</given-names></name><name><surname>Rekate</surname><given-names>HL</given-names></name></person-group>. <article-title>Cerebrospinal fluid control system</article-title>. <source>Proc IEEE</source>. (<year>1988</year>) <volume>76</volume>(<issue>9</issue>):<fpage>1226</fpage>&#x2013;<lpage>35</lpage>. <pub-id pub-id-type="doi">10.1109/5.9669</pub-id></citation></ref>
<ref id="B84"><label>84.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Osaka</surname><given-names>K</given-names></name><name><surname>Murata</surname><given-names>T</given-names></name><name><surname>Okamoto</surname><given-names>S</given-names></name><name><surname>Ohta</surname><given-names>T</given-names></name><name><surname>Ozaki</surname><given-names>T</given-names></name><name><surname>Maeda</surname><given-names>T</given-names></name><etal/></person-group> <article-title>Development of a new, completely implantable intraventricular pressure meter and preliminary report of its clinical experience</article-title>. <source>Neurol Med Chir (Tokyo)</source>. (<year>1981</year>) <volume>21</volume>(<issue>10</issue>):<fpage>1051</fpage>&#x2013;<lpage>60</lpage>. <pub-id pub-id-type="doi">10.2176/nmc.21.1051</pub-id><pub-id pub-id-type="pmid">6172724</pub-id></citation></ref>
<ref id="B85"><label>85.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>De Jong</surname><given-names>DA</given-names></name><name><surname>Maas</surname><given-names>AI</given-names></name><name><surname>v d Voort</surname><given-names>E</given-names></name></person-group>. <article-title>Non-invasive intracranial pressure monitoring. A technique for reproducible fontanelle pressure measurements.</article-title> <source>Z Kinderchir</source>. (<year>1984</year>) <volume>39</volume>(<issue>4</issue>):<fpage>274</fpage>&#x2013;<lpage>6</lpage>. <pub-id pub-id-type="doi">10.1055/s-2008-1044227</pub-id><pub-id pub-id-type="pmid">6495883</pub-id></citation></ref>
<ref id="B86"><label>86.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Velazquez Sanchez</surname><given-names>VF</given-names></name><name><surname>Al Dayri</surname><given-names>G</given-names></name><name><surname>Tschan</surname><given-names>CA</given-names></name></person-group>. <article-title>Long-term telemetric intracranial pressure monitoring for diagnosis and therapy optimisation of idiopathic intracranial hypertension</article-title>. <source>BMC Neurol</source>. (<year>2021</year>) <volume>21</volume>(<issue>1</issue>):<fpage>343</fpage>. <pub-id pub-id-type="doi">10.1186/s12883-021-02349-8</pub-id><pub-id pub-id-type="pmid">34493231</pub-id></citation></ref>
<ref id="B87"><label>87.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tirado-Caballero</surname><given-names>J</given-names></name><name><surname>Munoz-Nunez</surname><given-names>A</given-names></name><name><surname>Rocha-Romero</surname><given-names>S</given-names></name><name><surname>Rivero-Garvia</surname><given-names>M</given-names></name><name><surname>Gomez-Gonzalez</surname><given-names>E</given-names></name><name><surname>Marquez-Rivas</surname><given-names>J</given-names></name></person-group>. <article-title>Long-term reliability of the telemetric Neurovent-P-tel sensor: <italic>in vivo</italic> case report</article-title>. <source>J Neurosurg</source>. (<year>2019</year>) <volume>131</volume>(<issue>2</issue>):<fpage>578</fpage>&#x2013;<lpage>81</lpage>. <pub-id pub-id-type="doi">10.3171/2018.4.JNS172988</pub-id><pub-id pub-id-type="pmid">30168735</pub-id></citation></ref>
<ref id="B88"><label>88.</label><citation citation-type="other"><person-group person-group-type="author"><name><surname>Thiem</surname><given-names>R</given-names></name></person-group>. <article-title>Field Safety Notice for Neurovent-P-Tel. Raumedic AG, Contract No.: FSN 001/21</article-title>. (<year>2021</year>).</citation></ref>
<ref id="B89"><label>89.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Oertel</surname><given-names>JMK</given-names></name><name><surname>Huelser</surname><given-names>MJM</given-names></name></person-group>. <article-title>Telemetric home monitoring of intracranial pressure-where are we now</article-title>. <source>Acta Neurochir (Wien)</source>. (<year>2019</year>) <volume>161</volume>(<issue>8</issue>):<fpage>1603</fpage>&#x2013;<lpage>4</lpage>. <pub-id pub-id-type="doi">10.1007/s00701-019-03962-w</pub-id><pub-id pub-id-type="pmid">31187266</pub-id></citation></ref>
<ref id="B90"><label>90.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Oertel</surname><given-names>JMK</given-names></name><name><surname>Huelser</surname><given-names>MJM</given-names></name></person-group>. <article-title>Benefits and obstacles of telemetric ICP monitoring</article-title>. <source>Acta Neurochir (Wien)</source>. (<year>2021</year>) <volume>163</volume>(<issue>4</issue>):<fpage>1083</fpage>&#x2013;<lpage>5</lpage>. <pub-id pub-id-type="doi">10.1007/s00701-021-04730-5</pub-id><pub-id pub-id-type="pmid">33550517</pub-id></citation></ref>
<ref id="B91"><label>91.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hezarjaribi</surname><given-names>Y</given-names></name><name><surname>Hamidon</surname><given-names>M</given-names></name></person-group>. <article-title>Theoretical formulation to evaluate capacitance for before and after touch point MEMS capacitive pressure sensors</article-title>. <source>Int J Eng Sci</source>. (<year>2013</year>) <volume>2</volume>(<issue>1</issue>):<fpage>278</fpage>&#x2013;<lpage>86</lpage>.</citation></ref>
<ref id="B92"><label>92.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lilja-Cyron</surname><given-names>A</given-names></name><name><surname>Kelsen</surname><given-names>J</given-names></name><name><surname>Andresen</surname><given-names>M</given-names></name><name><surname>Fugleholm</surname><given-names>K</given-names></name><name><surname>Juhler</surname><given-names>M</given-names></name></person-group>. <article-title>Feasibility of telemetric intracranial pressure monitoring in the neuro intensive care unit</article-title>. <source>J Neurotrauma</source>. (<year>2018</year>) <volume>35</volume>(<issue>14</issue>):<fpage>1578</fpage>&#x2013;<lpage>86</lpage>. <pub-id pub-id-type="doi">10.1089/neu.2017.5589</pub-id><pub-id pub-id-type="pmid">29648985</pub-id></citation></ref>
<ref id="B93"><label>93.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Riedel</surname><given-names>CS</given-names></name><name><surname>Martinez-Tejada</surname><given-names>I</given-names></name><name><surname>Andresen</surname><given-names>M</given-names></name><name><surname>Wilhjelm</surname><given-names>JE</given-names></name><name><surname>Jennum</surname><given-names>P</given-names></name><name><surname>Juhler</surname><given-names>M</given-names></name></person-group>. <article-title>Transient intracranial pressure elevations (B waves) are associated with sleep apnea</article-title>. <source>Fluids Barriers CNS</source>. (<year>2023</year>) <volume>20</volume>(<issue>1</issue>):<fpage>69</fpage>. <pub-id pub-id-type="doi">10.1186/s12987-023-00469-6</pub-id><pub-id pub-id-type="pmid">37784168</pub-id></citation></ref>
<ref id="B94"><label>94.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Omidbeigi</surname><given-names>M</given-names></name><name><surname>Mousavi</surname><given-names>MS</given-names></name><name><surname>Meknatkhah</surname><given-names>S</given-names></name><name><surname>Edalatfar</surname><given-names>M</given-names></name><name><surname>Bari</surname><given-names>A</given-names></name><name><surname>Sharif-Alhoseini</surname><given-names>M</given-names></name></person-group>. <article-title>Telemetric intracranial pressure monitoring: a systematic review</article-title>. <source>Neurocrit Care</source>. (<year>2021</year>) <volume>34</volume>(<issue>1</issue>):<fpage>291</fpage>&#x2013;<lpage>300</lpage>. <pub-id pub-id-type="doi">10.1007/s12028-020-00992-6</pub-id><pub-id pub-id-type="pmid">32430803</pub-id></citation></ref>
<ref id="B95"><label>95.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Foreman</surname><given-names>PM</given-names></name><name><surname>Hendrix</surname><given-names>P</given-names></name><name><surname>Griessenauer</surname><given-names>CJ</given-names></name><name><surname>Schmalz</surname><given-names>PG</given-names></name><name><surname>Harrigan</surname><given-names>MR</given-names></name></person-group>. <article-title>External ventricular drain placement in the intensive care unit versus operating room: evaluation of complications and accuracy</article-title>. <source>Clin Neurol Neurosurg</source>. (<year>2015</year>) <volume>128</volume>:<fpage>94</fpage>&#x2013;<lpage>100</lpage>. <pub-id pub-id-type="doi">10.1016/j.clineuro.2014.09.026</pub-id><pub-id pub-id-type="pmid">25436470</pub-id></citation></ref>
<ref id="B96"><label>96.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Liu</surname><given-names>H</given-names></name><name><surname>Wang</surname><given-names>W</given-names></name><name><surname>Cheng</surname><given-names>F</given-names></name><name><surname>Yuan</surname><given-names>Q</given-names></name><name><surname>Yang</surname><given-names>J</given-names></name><name><surname>Hu</surname><given-names>J</given-names></name><etal/></person-group> <article-title>External ventricular drains versus intraparenchymal intracranial pressure monitors in traumatic brain injury: a prospective observational study</article-title>. <source>World Neurosurg</source>. (<year>2015</year>) <volume>83</volume>(<issue>5</issue>):<fpage>794</fpage>&#x2013;<lpage>800</lpage>. <pub-id pub-id-type="doi">10.1016/j.wneu.2014.12.040</pub-id><pub-id pub-id-type="pmid">25541084</pub-id></citation></ref>
<ref id="B97"><label>97.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tavakoli</surname><given-names>S</given-names></name><name><surname>Peitz</surname><given-names>G</given-names></name><name><surname>Ares</surname><given-names>W</given-names></name><name><surname>Hafeez</surname><given-names>S</given-names></name><name><surname>Grandhi</surname><given-names>R</given-names></name></person-group>. <article-title>Complications of invasive intracranial pressure monitoring devices in neurocritical care</article-title>. <source>Neurosurg Focus</source>. (<year>2017</year>) <volume>43</volume>(<issue>5</issue>):<fpage>E6</fpage>. <pub-id pub-id-type="doi">10.3171/2017.8.Focus17450</pub-id><pub-id pub-id-type="pmid">29088962</pub-id></citation></ref>
<ref id="B98"><label>98.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Poblete</surname><given-names>R</given-names></name><name><surname>Zheng</surname><given-names>L</given-names></name><name><surname>Raghavan</surname><given-names>R</given-names></name><name><surname>Cen</surname><given-names>S</given-names></name><name><surname>Amar</surname><given-names>A</given-names></name><name><surname>Sanossian</surname><given-names>N</given-names></name><etal/></person-group> <article-title>Trends in ventriculostomy-associated infections and mortality in aneurysmal subarachnoid hemorrhage: data from the nationwide inpatient sample</article-title>. <source>World Neurosurg</source>. (<year>2017</year>) <volume>99</volume>:<fpage>599</fpage>&#x2013;<lpage>604</lpage>. <pub-id pub-id-type="doi">10.1016/j.wneu.2016.12.073</pub-id><pub-id pub-id-type="pmid">28034809</pub-id></citation></ref>
<ref id="B99"><label>99.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Holloway</surname><given-names>KL</given-names></name><name><surname>Barnes</surname><given-names>T</given-names></name><name><surname>Choi</surname><given-names>S</given-names></name><name><surname>Bullock</surname><given-names>R</given-names></name><name><surname>Marshall</surname><given-names>LF</given-names></name><name><surname>Eisenberg</surname><given-names>HM</given-names></name><etal/></person-group> <article-title>Ventriculostomy infections: the effect of monitoring duration and catheter exchange in 584 patients</article-title>. <source>J Neurosurg</source>. (<year>1996</year>) <volume>85</volume>(<issue>3</issue>):<fpage>419</fpage>&#x2013;<lpage>24</lpage>. <pub-id pub-id-type="doi">10.3171/jns.1996.85.3.0419</pub-id><pub-id pub-id-type="pmid">8751626</pub-id></citation></ref>
<ref id="B100"><label>100.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dimitriou</surname><given-names>J</given-names></name><name><surname>Levivier</surname><given-names>M</given-names></name><name><surname>Gugliotta</surname><given-names>M</given-names></name></person-group>. <article-title>Comparison of complications in patients receiving different types of intracranial pressure monitoring: a retrospective study in a single center in Switzerland</article-title>. <source>World Neurosurg</source>. (<year>2016</year>) <volume>89</volume>:<fpage>641</fpage>&#x2013;<lpage>6</lpage>. <pub-id pub-id-type="doi">10.1016/j.wneu.2015.11.037</pub-id><pub-id pub-id-type="pmid">26675480</pub-id></citation></ref>
<ref id="B101"><label>101.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Shellock</surname><given-names>FG</given-names></name><name><surname>Knebel</surname><given-names>J</given-names></name><name><surname>Prat</surname><given-names>AD</given-names></name></person-group>. <article-title>Evaluation of MRI issues for a new neurological implant, the sensor reservoir</article-title>. <source>Magn Reson Imaging</source>. (<year>2013</year>) <volume>31</volume>(<issue>7</issue>):<fpage>1245</fpage>&#x2013;<lpage>50</lpage>. <pub-id pub-id-type="doi">10.1016/j.mri.2013.03.012</pub-id><pub-id pub-id-type="pmid">23602731</pub-id></citation></ref>
<ref id="B102"><label>102.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Freimann</surname><given-names>FB</given-names></name><name><surname>&#x00D6;tv&#x00F6;s</surname><given-names>J</given-names></name><name><surname>Chopra</surname><given-names>SS</given-names></name><name><surname>Vajkoczy</surname><given-names>P</given-names></name><name><surname>Wolf</surname><given-names>S</given-names></name><name><surname>Sprung</surname><given-names>C</given-names></name></person-group>. <article-title>Differential pressure in shunt therapy: investigation of position-dependent intraperitoneal pressure in a porcine model</article-title>. <source>J Neurosurg Pediatr</source>. (<year>2013</year>) <volume>12</volume>(<issue>6</issue>):<fpage>575</fpage>&#x2013;<lpage>81</lpage>. <pub-id pub-id-type="doi">10.3171/2013.8.Peds13205</pub-id><pub-id pub-id-type="pmid">24093588</pub-id></citation></ref>
<ref id="B103"><label>103.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yangi</surname><given-names>K</given-names></name><name><surname>On</surname><given-names>TJ</given-names></name><name><surname>Xu</surname><given-names>Y</given-names></name><name><surname>Gholami</surname><given-names>AS</given-names></name><name><surname>Hong</surname><given-names>J</given-names></name><name><surname>Reed</surname><given-names>AG</given-names></name><etal/></person-group> <article-title>Artificial intelligence integration in surgery through hand and instrument tracking: a systematic literature review</article-title>. <source>Front Surg</source>. (<year>2025</year>) <volume>12</volume>:<fpage>1528362</fpage>. <pub-id pub-id-type="doi">10.3389/fsurg.2025.1528362</pub-id><pub-id pub-id-type="pmid">40078701</pub-id></citation></ref>
<ref id="B104"><label>104.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yangi</surname><given-names>K</given-names></name><name><surname>Hong</surname><given-names>J</given-names></name><name><surname>Gholami</surname><given-names>AS</given-names></name><name><surname>On</surname><given-names>TJ</given-names></name><name><surname>Reed</surname><given-names>AG</given-names></name><name><surname>Puppalla</surname><given-names>P</given-names></name><etal/></person-group> <article-title>Deep learning in neurosurgery: a systematic literature review with a structured analysis of applications across subspecialties</article-title>. <source>Front Neurol</source>. (<year>2025</year>) <volume>16</volume>:<fpage>1532398</fpage>. <pub-id pub-id-type="doi">10.3389/fneur.2025.1532398</pub-id><pub-id pub-id-type="pmid">40308224</pub-id></citation></ref>
<ref id="B105"><label>105.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lee</surname><given-names>S</given-names></name><name><surname>Liu</surname><given-names>S</given-names></name><name><surname>Bristol</surname><given-names>RE</given-names></name><name><surname>Preul</surname><given-names>MC</given-names></name><name><surname>Blain Christen</surname><given-names>J</given-names></name></person-group>. <article-title>Hydrogel check-valves for the treatment of hydrocephalic fluid retention with wireless fully-passive sensor for the intracranial pressure measurement</article-title>. <source>Gels</source>. (<year>2022</year>) <volume>8</volume>(<issue>5</issue>):<fpage>276</fpage>. <pub-id pub-id-type="doi">10.3390/gels8050276</pub-id><pub-id pub-id-type="pmid">35621574</pub-id></citation></ref>
<ref id="B106"><label>106.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dodd</surname><given-names>WS</given-names></name><name><surname>Dayton</surname><given-names>O</given-names></name><name><surname>Lucke-Wold</surname><given-names>B</given-names></name><name><surname>Reitano</surname><given-names>C</given-names></name><name><surname>Sorrentino</surname><given-names>Z</given-names></name><name><surname>Busl</surname><given-names>KM</given-names></name></person-group>. <article-title>Decrease in cortical vein opacification predicts outcome after aneurysmal subarachnoid hemorrhage</article-title>. <source>J Neurointerv Surg</source>. (<year>2023</year>) <volume>15</volume>(<issue>11</issue>):<fpage>1105</fpage>&#x2013;<lpage>10</lpage>. <pub-id pub-id-type="doi">10.1136/jnis-2022-019578</pub-id><pub-id pub-id-type="pmid">36456184</pub-id></citation></ref>
<ref id="B107"><label>107.</label><citation citation-type="other"><person-group person-group-type="author"><name><surname>Cosman</surname><given-names>ER</given-names></name></person-group>. <article-title>Pressure-Balanced Telemetric Pressure Sensing System and Method Therefore</article-title>. (<year>1987</year>).</citation></ref>
<ref id="B108"><label>108.</label><citation citation-type="other"><person-group person-group-type="author"><name><surname>Ko</surname><given-names>WH</given-names></name><name><surname>Leung</surname><given-names>AM</given-names></name></person-group>. <article-title>Pressure Telemetry Implant</article-title>. (<year>1985</year>).</citation></ref>
<ref id="B109"><label>109.</label><citation citation-type="other"><person-group person-group-type="author"><name><surname>Sakaguchi</surname><given-names>I</given-names></name><name><surname>Osaka</surname><given-names>K</given-names></name><name><surname>Hokari</surname><given-names>S</given-names></name><name><surname>Takahashi</surname><given-names>K</given-names></name></person-group>, <article-title>inventors; Intracranial Pressure Gauge</article-title>. (<year>1982</year>).</citation></ref></ref-list>
</back>
</article>