<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="research-article" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xml:lang="EN">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Oral Health</journal-id>
<journal-title>Frontiers in Oral Health</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Oral Health</abbrev-journal-title>
<issn pub-type="epub">2673-4842</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/froh.2025.1539527</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Oral Health</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>The effects of a carbonated beverage on the optical properties and microhardness of preheated bulk-fill composite resin restorations</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes"><name><surname>Farghal</surname><given-names>Nancy Soliman</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="corresp" rid="cor1">&#x002A;</xref><uri xlink:href="https://loop.frontiersin.org/people/2912343/overview"/><role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/><role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/><role content-type="https://credit.niso.org/contributor-roles/methodology/"/><role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/></contrib>
<contrib contrib-type="author"><name><surname>Abu Shamleh</surname><given-names>Ayya</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/2913812/overview" /><role content-type="https://credit.niso.org/contributor-roles/investigation/"/><role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/></contrib>
<contrib contrib-type="author"><name><surname>Al Hurmuzi</surname><given-names>Osamah</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref><role content-type="https://credit.niso.org/contributor-roles/investigation/"/><role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/></contrib>
<contrib contrib-type="author"><name><surname>Mahmoud</surname><given-names>Okba</given-names></name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<xref ref-type="aff" rid="aff4"><sup>4</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/2913934/overview" /><role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/><role content-type="https://credit.niso.org/contributor-roles/methodology/"/><role content-type="https://credit.niso.org/contributor-roles/supervision/"/><role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/></contrib>
</contrib-group>
<aff id="aff1"><label><sup>1</sup></label><institution>Department of Restorative Dentistry and Endodontics, RAK College of Dental Sciences, RAK Medical and Health Sciences University</institution>, <addr-line>Ras Al-Khaimah</addr-line>, <country>United Arab Emirates</country></aff>
<aff id="aff2"><label><sup>2</sup></label><institution>Department of Dental Biomaterials, Faculty of Dentistry, Tanta University</institution>, <addr-line>Tanta</addr-line>, <country>Egypt</country></aff>
<aff id="aff3"><label><sup>3</sup></label><institution>Clinical Sciences Department, College of Dentistry, Ajman University</institution>, <addr-line>Ajman</addr-line>, <country>United Arab Emirates</country></aff>
<aff id="aff4"><label><sup>4</sup></label><institution>Centre of Medical and Bioallied Health Sciences Research, Ajman University</institution>, <addr-line>Ajman</addr-line>, <country>United Arab Emirates</country></aff>
<author-notes>
<fn fn-type="edited-by"><p><bold>Edited by:</bold> Mary Anne Sampaio Melo, University of Maryland, United States</p></fn>
<fn fn-type="edited-by"><p><bold>Reviewed by:</bold> Abdulrahman A. Balhaddad, Imam Abdulrahman Bin Faisal University, Saudi Arabia</p>
<p>Vaishnavi Rajaraman, Saveetha Institute of Medical and Technical Sciences, India</p>
<p>Guilherme Anziliero Arossi, University of Maryland, United States</p></fn>
<corresp id="cor1"><label>&#x002A;</label><bold>Correspondence:</bold> Nancy Soliman Farghal <email>nancy.soliman@rakmhsu.ac.ae</email></corresp>
</author-notes>
<pub-date pub-type="epub"><day>02</day><month>06</month><year>2025</year></pub-date>
<pub-date pub-type="collection"><year>2025</year></pub-date>
<volume>6</volume><elocation-id>1539527</elocation-id>
<history>
<date date-type="received"><day>04</day><month>12</month><year>2024</year></date>
<date date-type="accepted"><day>15</day><month>05</month><year>2025</year></date>
</history>
<permissions>
<copyright-statement>&#x00A9; 2025 Farghal, Abu Shamleh, Al Hurmuzi and Mahmoud.</copyright-statement>
<copyright-year>2025</copyright-year><copyright-holder>Farghal, Abu Shamleh, Al Hurmuzi and Mahmoud</copyright-holder><license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the <ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by/4.0/">Creative Commons Attribution License (CC BY)</ext-link>. The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license>
</permissions>
<abstract><sec><title>Introduction</title>
<p>Preheating the high-viscosity forms of bulk-fill resin composites is recommended to enhance their flow and adaptability. Nevertheless, the impact of preheating on their characteristics upon exposure to carbonated beverages remains unclear. This study aims to evaluate the effect of a Cola beverage on the properties of preheated and non-preheated high-viscosity bulk-fill composite resins <italic>in vitro</italic>.</p>
</sec><sec><title>Methods</title>
<p>Forty disc-shaped specimens were prepared from each of BEAUTIFIL-Bulk Restorative (BB) and Filtek One Bulk-fill (FOB) composite resin, then divided into two groups (<italic>n</italic>&#x2009;&#x003D;&#x2009;20), either preheated to 68&#x00B0;C for 15&#x2005;min or kept at room temperature before polymerization, then specimens were immersed in Alkozay Cola beverage for 30 days (3 periods of 15&#x2005;min/day). Color stability (&#x0394;E<sub>00</sub>), surface gloss (GU) and Vickers Microhardness (VHN) were recorded before and after the Cola immersion. The data was analyzed with Two-way ANOVA, Three-way ANOVA and Tukey&#x0027;s HSD <italic>post hoc</italic> test using SPSS software at 95&#x0025; significance level.</p>
</sec><sec><title>Results</title>
<p>The color change was significantly higher in BB than FOB in all groups (<italic>P</italic>&#x2009;&#x003C;&#x2009;0:001), FOB had a significant reduction in color change after preheating (<italic>P</italic>&#x2009;&#x003C;&#x2009;0.05) while BB had no significant change (<italic>P</italic>&#x2009;&#x003E;&#x2009;0.05). Preheating significantly increased the gloss of BB and reduced that of FOB (<italic>P</italic>&#x2009;&#x003C;&#x2009;0.001), however, Cola beverage significantly reduced the gloss of all the groups (<italic>P</italic>&#x2009;&#x003C;&#x2009;0.001). Preheating significantly increased the microhardness of both materials (<italic>P</italic>&#x2009;&#x003C;&#x2009;0.001), however, Cola beverage significantly reduced the microhardness of all the groups (<italic>P</italic>&#x2009;&#x003C;&#x2009;0.001).</p>
</sec><sec><title>Conclusion</title>
<p>Although the preheating of high-viscosity bulk-fill composites significantly improved their microhardness and improved the surface gloss of FOB, it did not protect both composites against the Cola drink attack. Preheated FOB showed improved color stability after the Cola immersion, but not to a clinically acceptable limit.</p>
</sec>
</abstract>
<kwd-group>
<kwd>acidic drink</kwd>
<kwd>bulk-fill composite</kwd>
<kwd>color stability</kwd>
<kwd>carbonated beverage</kwd>
<kwd>giomer</kwd>
<kwd>gloss</kwd>
<kwd>microhardness</kwd>
<kwd>preheated composite</kwd>
</kwd-group><contract-sponsor id="cn001">Ras Al-Khaimah Medical and Health Sciences University and Ajman University of Science and Technology</contract-sponsor><counts>
<fig-count count="2"/>
<table-count count="6"/><equation-count count="1"/><ref-count count="57"/><page-count count="10"/><word-count count="0"/></counts><custom-meta-wrap><custom-meta><meta-name>section-at-acceptance</meta-name><meta-value>Oral Health and Nutrition</meta-value></custom-meta></custom-meta-wrap>
</article-meta>
</front>
<body><sec id="s1" sec-type="intro"><label>1</label><title>Introduction</title>
<p>Conventional resin-based composites have been successfully used in the field of aesthetic restorative dentistry for many years, however, their limited depth of cure into small increments of 2&#x2005;mm thickness is still considered a critical point that limits their performance, rendering the conventional incremental composite placement technique sensitive and time-consuming (<xref ref-type="bibr" rid="B1">1</xref>, <xref ref-type="bibr" rid="B2">2</xref>). Recently, a novel category of resin-based composites, known as &#x201C;bulk-fill&#x201D; composites, has been introduced to the dental market aiming at reducing the cost and saving time (<xref ref-type="bibr" rid="B3">3</xref>). The distinctive feature of these novel materials is their ability to be cured in a single step and placed in bulks of 4&#x2005;mm thickness, in contrast to the conventional incremental placement technique, without affecting the degree of conversion, polymerization shrinkage, or their adaptation to the cavity walls and margins (<xref ref-type="bibr" rid="B4">4</xref>).</p>
<p>Bulk-fill resin composites are available in two different viscosities which highly influence their application efficiency and cavity wall adaptation. Low-viscosity bulk-fill resin composites are flowable in consistency which enables their adaptation to the cavity floors even in deeper and less accessible areas, this reduced viscosity is associated with decreased filler loading which reduces their surface wear resistance, and therefore, these low-viscosity forms must be capped with a layer of conventional composite materials. on the other hand, high-viscosity bulk-fill resin composites are designed to be used without a capping layer, as they have higher filler loading and enhanced mechanical properties, the higher filler loading and higher viscosity of the material reduce their adaptability to the cavity walls and margins and creates difficulty in sculpting the surface layer (<xref ref-type="bibr" rid="B5">5</xref>) (<xref ref-type="bibr" rid="B6">6</xref>). Accordingly, preheating the composite resin before its application is currently gaining popularity among dental practitioners due to its potential to enhance the extrusion and flow of high-viscosity composites, as well as for its potential to reduce microleakage and marginal adaptation (<xref ref-type="bibr" rid="B7">7</xref>). It has been demonstrated that the polymerization process is optimized and the degree of conversion is increased by increasing the temperature before the polymerization (<xref ref-type="bibr" rid="B8">8</xref>, <xref ref-type="bibr" rid="B9">9</xref>).</p>
<p>In addition to enhancing the sculpting and handling characteristics of bulk-fill composite resins, it is anticipated that these direct restorative materials exhibit good aesthetic qualities and durability (<xref ref-type="bibr" rid="B10">10</xref>). The consumed oral beverages remain a critical point that affects the oral health (<xref ref-type="bibr" rid="B11">11</xref>). Despite advancements in the organic matrix and particle size of composite resins, color stability and gloss retention remain a prevalent issue for both patients and dentists (<xref ref-type="bibr" rid="B12">12</xref>, <xref ref-type="bibr" rid="B13">13</xref>). The exposure of bulk-fill composite resins to different beverages in the oral environment may lead to color alteration due to intrinsic or external causes as reported in previous studies (<xref ref-type="bibr" rid="B14">14</xref>, <xref ref-type="bibr" rid="B15">15</xref>). Besides, acidic beverages with low pH are also known to degrade the matrix structure of resins (<xref ref-type="bibr" rid="B16">16</xref>). Previous studies showed the negative effect of acidic beverages on the surface hardness of bulk-fill composite resin, which reflects the ability of the material to resist abrasion during function. Consequently, the restoration&#x0027;s durability may be influenced by the factors that impact its hardness (<xref ref-type="bibr" rid="B17">17</xref>&#x2013;<xref ref-type="bibr" rid="B19">19</xref>).</p>
<p>Despite the reported advantages of preheating the composite resin materials on enhanced degree of conversion and improved marginal adaptation due to reduced viscosity (<xref ref-type="bibr" rid="B8">8</xref>, <xref ref-type="bibr" rid="B20">20</xref>, <xref ref-type="bibr" rid="B21">21</xref>) there is insufficient data about the preheating effect on optical characteristics and surface hardness of highly viscous bulk-fill composites. Thus, the current investigation aims to explore the influence of preheating two highly viscous bulk-fill composite resins on their color stability, surface gloss and microhardness after immersion in a commercial carbonated beverage. The first null hypothesis states that there will be no difference between the two materials regarding the tested properties. The second null hypothesis is that there will be no difference between the two materials in preheated and non-preheated state, and the third null hypothesis states that there will be no difference in the tested properties after immersion in the carbonated beverage.</p>
</sec>
<sec id="s2" sec-type="methods"><label>2</label><title>Materials and methods</title>
<sec id="s2a"><label>2.1</label><title>Study design</title>
<p>This study was conducted following the approval of the Research and Ethics Committee Ref. No: RAKMHSU-REC-9-2023/24-UG. Two high-viscosity bulk-fill composite materials were utilized in the current study, BEAUTIFIL-Bulk Restorative (BB), Shofu Inc, Kyoto, Japan, and Filtek<sup>TM</sup> One Bulk-fill Restorative (FOB), 3M ESPE, St Paul, MN, USA. The details of each material are listed in (<xref ref-type="table" rid="T1">Table&#x00A0;1</xref>). <xref ref-type="fig" rid="F1">Figure&#x00A0;1</xref> illustrates the study&#x0027;s methodology.</p>
<table-wrap id="T1" position="float"><label>Table 1</label>
<caption><p>Material names, compositions and manufacturers of the study.</p></caption>
<table frame="hsides" rules="groups">
<colgroup>
<col align="left"/>
<col align="center"/>
<col align="left"/>
<col align="left"/>
<col align="center"/>
</colgroup>
<thead>
<tr>
<th valign="top" align="left">Brand name</th>
<th valign="top" align="center">Depth of cure, shade</th>
<th valign="top" align="center">Composition</th>
<th valign="top" align="center">Manufacturer</th>
<th valign="top" align="center">Lot no.</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left" rowspan="2">BEAUTIFIL-Bulk Restorative. (BB)</td>
<td valign="top" align="center" rowspan="2">4&#x2005;mm, A2</td>
<td valign="top" align="left">Matrix: Bis-GMA, UDMA, Bis-MPEPP, TEGDMA</td>
<td valign="top" align="left" rowspan="2">Shofu Inc, Kyoto, Japan</td>
<td valign="top" align="center" rowspan="2">022259</td>
</tr>
<tr>
<td valign="top" align="left">Filler (w&#x0025;/v&#x0025;): 87/74.5<break/>S-PRG filler based on fluoroboroaluminosilicate glass</td>
</tr>
<tr>
<td valign="top" align="left" rowspan="2">Filtek<sup>TM</sup> One<break/>Bulk-fill. (FOB)</td>
<td valign="top" align="center" rowspan="2">5&#x2005;mm, A2</td>
<td valign="top" align="left">Matrix: AUDMA, AFM, UDMA, diurethane-DMA, and 1, 12-dodecane- DMA</td>
<td valign="top" align="left" rowspan="2">3M ESPE, St Paul, MN, USA</td>
<td valign="top" align="center" rowspan="2">9979066</td>
</tr>
<tr>
<td valign="top" align="left">Filler (w&#x0025;/v&#x0025;): 76.5/58.4<break/>ytterbium trifluoride, zirconia/Silica</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="table-fn1"><p>Abbreviations: AFM, additive fragmentation monomer; AUDMA, aromatic urethane dimethacrylate; DMA, dimethacrylate; Bis-GMA, bisphenol A glycidyl methacrylate; UDMA, urethane dimethacrylate; Bis-MPEPP, 2,2-bis(4-methacryloxy poly-methoxyphenyl) propane; TEGDMA, triethylene glycol dimethacrylate; wt&#x0025;, weight percentage; v&#x0025;, volume percentage.</p></fn>
</table-wrap-foot>
</table-wrap>
<fig id="F1" position="float"><label>Figure 1</label>
<caption><p>The experimental study design.</p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="froh-06-1539527-g001.tif"/>
</fig>
</sec>
<sec id="s2b"><label>2.2</label><title>Determination of the sample size</title>
<p>The sample size in the current study was calculated using the G&#x002A;Power program v. 3.1.9.7 for Windows, based on four experimental groups. The power was set at 0.8, and the effect size was set to 0.4, as reported in previous studies (<xref ref-type="bibr" rid="B10">10</xref>, <xref ref-type="bibr" rid="B22">22</xref>), with a 0.05 significance level. Accordingly, a minimum of 19 specimens per group was calculated and increased to 20 specimens per group to reduce sampling errors.</p>
</sec>
<sec id="s2c"><label>2.3</label><title>Fabrication of the specimens</title>
<p>A total of 80 disc-shaped specimens, 40 of each restorative material, were prepared. The specimens were fabricated utilizing a silicon mold (10&#x2005;mm diameter &#x0026; 2&#x2005;mm thickness). The mold was positioned over a glass plate topped with a 10-mm wide polyester strip. After the application of each tested material within the mold, another similar polyester strip was delicately pressed with a glass plate over the specimen to eliminate excess material and attain a uniform smooth surface. Specimens were subjected to light curing for 20&#x2005;s under the manufacturer&#x0027;s guidelines on top and bottom surfaces utilizing an LED curing light (Elipar&#x2122; DeepCure-L 3M ESPE, St Paul, USA) at an intensity of approximately 1,470&#x2005;mW/cm<sup>2</sup>. The light intensity was frequently verified using the built-in radiometer to maintain a consistent light output. For the preheated specimens, a composite heater (AZDENT Dental Composite Heater, China) was used and its temperature was set at 68&#x00B0;C in which the composite syringes were kept for 15&#x2005;min before use in each specimen fabrication. After polymerization, the specimens were incubated in distilled water at 37&#x00B0;C for 24&#x2005;h to verify the completion of the polymerization process.</p>
</sec>
<sec id="s2d"><label>2.4</label><title>The grouping of the specimens</title>
<p>Specimens of each tested material were randomly divided into two groups (<italic>n</italic>&#x2009;&#x003D;&#x2009;20) according to their temperature before polymerization as follows:
<list list-type="simple">
<list-item><label>&#x2022;</label>
<p>Not pre-heated/Positive control group (NH): Specimens kept at room temperature (25&#x2009;&#x00B1;&#x2009;1&#x00B0;C) and polymerized without preheating.</p></list-item>
<list-item><label>&#x2022;</label>
<p>Preheated group (PH): Specimens were preheated to a temperature of (68&#x2009;&#x00B1;&#x2009;1&#x00B0;C) before polymerization.</p></list-item>
</list></p>
</sec>
<sec id="s2e"><label>2.5</label><title>Carbonated beverage immersion of the specimens</title>
<p>The specimens were immersed in a carbonated Cola beverage, Alokozay Cola (Alkozay Cola Production Company, Kabul, Afganistan), pH 2.3, for 30 days of challenge, (3 periods of 15&#x2005;min/day), at room temperature (25&#x2009;&#x00B1;&#x2009;1&#x00B0;C), after each period of immersion, specimens were washed with distilled water, dried thoroughly and then re-immersed in the Cola beverage. Specimens were stored in an incubator after each immersion cycle in distilled water at 37&#x00B0;C. After 30 days, the specimens were finally washed in distilled water for 10&#x2005;min and carefully dried before testing.</p>
</sec>
<sec id="s2f"><label>2.6</label><title>Testing of the specimens</title>
<sec id="s2f1"><label>2.6.1</label><title>Color stability test</title>
<p>The color stability was tested by recording the difference in color parameters recorded for each specimen initially (baseline) and after immersion in the Cola beverage, utilizing a spectrophotometer (VITA Easyshade&#x00AE; Advance 4.0, Vita Zahnfabrik, Bad S&#x00E4;ckingen, Germany) according to CIELAB color space system described by the Commission Internationale de l&#x0027;Eclairage. Following calibration of the apparatus to correspond with the manufacturer&#x0027;s guidelines, the 5&#x2005;mm-diameter spectrophotometer probe was positioned in the middle of the specimens; the specimens were positioned on a white non-reflecting surface to reduce interference from the background and under D65 Illumination source of light. Color changes (&#x0394;E<sub>00</sub>) of each sample were calculated according to the CIEDE2000 equation as follows (<xref ref-type="bibr" rid="B23">23</xref>):<disp-formula><mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="UDM1"><mml:mi mathvariant="normal">&#x0394;</mml:mi><mml:msub><mml:mi>E</mml:mi><mml:mn>00</mml:mn></mml:msub><mml:mo>=</mml:mo><mml:mrow><mml:mo>[</mml:mo><mml:mrow><mml:msup><mml:mrow><mml:mrow><mml:mo>(</mml:mo><mml:mrow><mml:mstyle displaystyle="true" scriptlevel="0"><mml:mrow><mml:mfrac><mml:mrow><mml:mi mathvariant="normal">&#x0394;</mml:mi><mml:msup><mml:mi>L</mml:mi><mml:mi mathvariant="normal">&#x2032;</mml:mi></mml:msup></mml:mrow><mml:mrow><mml:msub><mml:mi>K</mml:mi><mml:mi>L</mml:mi></mml:msub><mml:msub><mml:mi>S</mml:mi><mml:mi>L</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mrow></mml:mstyle></mml:mrow><mml:mo>)</mml:mo></mml:mrow></mml:mrow><mml:mn>2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:msup><mml:mrow><mml:mrow><mml:mo>(</mml:mo><mml:mrow><mml:mstyle displaystyle="true" scriptlevel="0"><mml:mrow><mml:mfrac><mml:mrow><mml:mi mathvariant="normal">&#x0394;</mml:mi><mml:msup><mml:mi>C</mml:mi><mml:mi mathvariant="normal">&#x2032;</mml:mi></mml:msup></mml:mrow><mml:mrow><mml:msub><mml:mi>K</mml:mi><mml:mi>C</mml:mi></mml:msub><mml:msub><mml:mi>S</mml:mi><mml:mi>C</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mrow></mml:mstyle></mml:mrow><mml:mo>)</mml:mo></mml:mrow></mml:mrow><mml:mn>2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:msup><mml:mrow><mml:mrow><mml:mo>(</mml:mo><mml:mrow><mml:mstyle displaystyle="true" scriptlevel="0"><mml:mrow><mml:mfrac><mml:mrow><mml:mi mathvariant="normal">&#x0394;</mml:mi><mml:msup><mml:mi>H</mml:mi><mml:mi mathvariant="normal">&#x2032;</mml:mi></mml:msup></mml:mrow><mml:mrow><mml:msub><mml:mi>K</mml:mi><mml:mi>H</mml:mi></mml:msub><mml:msub><mml:mi>S</mml:mi><mml:mi>H</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mrow></mml:mstyle></mml:mrow><mml:mo>)</mml:mo></mml:mrow></mml:mrow><mml:mn>2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:msub><mml:mi>R</mml:mi><mml:mi>T</mml:mi></mml:msub><mml:mrow><mml:mo>(</mml:mo><mml:mrow><mml:mstyle displaystyle="true" scriptlevel="0"><mml:mrow><mml:mfrac><mml:mrow><mml:mi mathvariant="normal">&#x0394;</mml:mi><mml:msup><mml:mi>C</mml:mi><mml:mi mathvariant="normal">&#x2032;</mml:mi></mml:msup></mml:mrow><mml:mrow><mml:msub><mml:mi>K</mml:mi><mml:mi>C</mml:mi></mml:msub><mml:msub><mml:mi>S</mml:mi><mml:mi>C</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mrow></mml:mstyle></mml:mrow><mml:mo>)</mml:mo></mml:mrow><mml:msup><mml:mrow><mml:mrow><mml:mo>(</mml:mo><mml:mrow><mml:mstyle displaystyle="true" scriptlevel="0"><mml:mrow><mml:mfrac><mml:mrow><mml:mi mathvariant="normal">&#x0394;</mml:mi><mml:msup><mml:mi>H</mml:mi><mml:mi mathvariant="normal">&#x2032;</mml:mi></mml:msup></mml:mrow><mml:mrow><mml:msub><mml:mi>K</mml:mi><mml:mi>H</mml:mi></mml:msub><mml:msub><mml:mi>S</mml:mi><mml:mi>H</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mrow></mml:mstyle></mml:mrow><mml:mo>)</mml:mo></mml:mrow></mml:mrow><mml:mrow><mml:mstyle displaystyle="true" scriptlevel="0"><mml:mrow><mml:mn>1</mml:mn><mml:mo>/</mml:mo><mml:mn>2</mml:mn></mml:mrow></mml:mstyle></mml:mrow></mml:msup></mml:mrow><mml:mo>]</mml:mo></mml:mrow></mml:math></disp-formula></p>
<p>Where, &#x0394;L&#x0384;, &#x0394;C&#x0384;, and &#x0394;H&#x0384; color parameters correspond to the differences in Lightness, Chroma, and Hue, respectively. R<sub>T</sub> is the rotation function, S<sub>L</sub>, S<sub>C</sub>, and S<sub>H</sub> are weighting functions, K<sub>L</sub>, K<sub>C</sub>, and K<sub>H</sub> are experiment correction parameters. In this investigation, these parametric variables were adjusted to 1 as a default value (<xref ref-type="bibr" rid="B13">13</xref>). The color stability values were further evaluated based on the 50:50&#x0025; perceptibility (0.80) and acceptability (1.8) thresholds reported by Paravina, et al. (<xref ref-type="bibr" rid="B24">24</xref>), and according to the ISO/TR 28642:2016 (<xref ref-type="bibr" rid="B25">25</xref>).</p>
</sec>
<sec id="s2f2"><label>2.6.2</label><title>Surface gloss test</title>
<p>Gloss measurements were performed using Novo-Curve glossmeter (Rhopoint Instrumentation Ltd., UK) with a 60&#x00B0; light incidence and reflection angles following the International Organization for Standardization standard for medium gloss materials ISO 2813:2014 (<xref ref-type="bibr" rid="B26">26</xref>). Each specimen was placed over a 2&#x2005;mm&#x2009;&#x00D7;&#x2009;2 mm measuring window on the instrument, which was then covered with a black shield to prevent external light exposure during the measurement. The device was calibrated using a calibration plate supplied by the manufacturer before measuring each composite group. Gloss values were quantified in gloss units (GU). A completely non-reflective surface is ascribed to a value of zero (0&#x2005;GU), whereas a highly polished surface with a refractive index of 1.567 reaches a value of 100&#x2005;GU. For each specimen, three readings were recorded by rotating the specimen 120&#x00B0; angle and then averaged to obtain its gloss value as reported by Ardu, et al. (<xref ref-type="bibr" rid="B27">27</xref>) The gloss was evaluated before and after the Cola beverage immersion for all the specimen, the pre-immersion values of each specimen served as a negative control.</p>
</sec>
<sec id="s2f3"><label>2.6.3</label><title>Microhardness test</title>
<p>Microhardness was assessed with a Vickers microhardness tester (FM-800, Future-Tech Corp. Japan), employing a 136&#x00B0; pyramidal diamond indenter to create a square indent on each specimen. The indenter was applied to each specimen&#x0027;s surface with a test force of 100&#x2005;g, sustained for a designated dwell duration of 15&#x2005;s. The dimensions of the indent were ascertained visually by measuring the two diagonals of the square indent using a 40&#x00D7; objective lens. The mean of the two diagonals was employed to compute the Vickers Microhardness Number (VHN) utilizing the subsequent formula:<disp-formula><mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="UDM2"><mml:mrow><mml:mi mathvariant="normal">VHN</mml:mi></mml:mrow><mml:mspace width=".1em"/><mml:mo>=</mml:mo><mml:mspace width=".1em"/><mml:mn>1.854</mml:mn><mml:mrow><mml:mspace width="0.25em"/></mml:mrow><mml:mrow><mml:mrow><mml:mi mathvariant="normal">F</mml:mi></mml:mrow><mml:mo>/</mml:mo><mml:mrow><mml:msup><mml:mrow><mml:mi mathvariant="normal">d</mml:mi></mml:mrow><mml:mn>2</mml:mn></mml:msup></mml:mrow></mml:mrow></mml:math></disp-formula>Where F: represents the applied force in Newton, and d: denotes the mean length of the two diagonals of each indentation. Three indentations for each specimen were documented and subsequently averaged to yield the final result. The microhardness was measured before and following the immersion in the Cola beverage, the pre-immersion values of each specimen served as a negative control.</p>
</sec>
</sec>
<sec id="s2g"><label>2.7</label><title>Statistical analysis</title>
<p>Means and standard deviations were calculated for each group. Data was statistically analyzed using the Statistical Program for Social Sciences (SPSS&#x00AE;, version 27, IBM, NY, USA). The data was normally distributed after performing the Kolmogorov&#x2013;Smirnov and Shapiro&#x2013;Wilk test. Color stability was analyzed using Two-way Analysis Of Variance ANOVA, while surface gloss and microhardness were analyzed using Three-way ANOVA to evaluate the interactions among the various groups, then multiple pairwise comparison procedures were conducted using Tukey&#x0027;s HSD <italic>post hoc</italic> test at 95&#x0025; level of significance (<italic>p</italic>&#x2009;&#x003C;&#x2009;0.05).</p>
</sec>
</sec>
<sec id="s3" sec-type="results"><label>3</label><title>Results</title>
<sec id="s3a"><label>3.1</label><title>Color stability results</title>
<p>The means and standard deviations of the color stability results are presented in <xref ref-type="fig" rid="F2">Figure&#x00A0;2</xref>. Two-way ANOVA revealed significant interaction within and among the tested groups, <italic>P</italic>&#x2009;&#x003C;&#x2009;0.001 as shown in <xref ref-type="table" rid="T2">Table&#x00A0;2</xref>. BB showed no significant difference in color change between NH and PH groups; &#x0394;E<sub>00</sub>&#x2009;&#x003D;&#x2009;15.2&#x2009;&#x00B1;&#x2009;5.9 and 13.5&#x2009;&#x00B1;&#x2009;(4.9) respectively, <italic>P</italic>&#x2009;&#x003D;&#x2009;0.13. Both NH and PH groups of BB color change values were significantly higher than the FOB groups, <italic>P</italic>&#x2009;&#x003C;&#x2009;0.001. The color change in FOB was significantly lower in the PH group than in the NH group 4.1&#x2009;&#x00B1;&#x2009;1.4 and 2.6&#x2009;&#x00B1;&#x2009;0.6 respectively, <italic>P</italic>&#x2009;&#x003D;&#x2009;0.03. The color change in all the groups of both tested composites was beyond the clinically acceptable &#x0394;E<sub>00</sub> threshold (&#x003E;1.8).</p>
<fig id="F2" position="float"><label>Figure 2</label>
<caption><p>Bar chart showing the color stability (&#x0394;E<sub>00</sub>) after Cola immersion of the tested materials, <italic>P</italic>&#x2009;&#x2264;&#x2009;0.05 was considered significant.</p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="froh-06-1539527-g002.tif"/>
</fig>
<table-wrap id="T2" position="float"><label>Table 2</label>
<caption><p>Two-way analysis of variance of the specimen&#x0027;s color stability after cola immersion (&#x0394;E<sub>00</sub>) as affected by the composite type and the pre-polymerization temperature.</p></caption>
<table frame="hsides" rules="groups">
<colgroup>
<col align="left"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
</colgroup>
<thead>
<tr>
<th valign="top" align="left">Source</th>
<th valign="top" align="center">Type III sum of squares</th>
<th valign="top" align="center">df</th>
<th valign="top" align="center">Mean square</th>
<th valign="top" align="center">F</th>
<th valign="top" align="center"><italic>P</italic>- value</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Corrected model</td>
<td valign="top" align="center">2,280.564<xref ref-type="table-fn" rid="table-fn2"><sup>a</sup></xref></td>
<td valign="top" align="center">3</td>
<td valign="top" align="center">760.188</td>
<td valign="top" align="center">50.402</td>
<td valign="top" align="center">0.000<xref ref-type="table-fn" rid="table-fn3">&#x002A;</xref></td>
</tr>
<tr>
<td valign="top" align="left">Intercept</td>
<td valign="top" align="center">5,908.203</td>
<td valign="top" align="center">1</td>
<td valign="top" align="center">5,908.203</td>
<td valign="top" align="center">391.728</td>
<td valign="top" align="center">0.000<xref ref-type="table-fn" rid="table-fn3">&#x002A;</xref></td>
</tr>
<tr>
<td valign="top" align="left">Composite type</td>
<td valign="top" align="center">2,185.095</td>
<td valign="top" align="center">1</td>
<td valign="top" align="center">2,185.095</td>
<td valign="top" align="center">144.877</td>
<td valign="top" align="center">0.000<xref ref-type="table-fn" rid="table-fn3">&#x002A;</xref></td>
</tr>
<tr>
<td valign="top" align="left">Polymerization temperature</td>
<td valign="top" align="center">89.253</td>
<td valign="top" align="center">1</td>
<td valign="top" align="center">89.253</td>
<td valign="top" align="center">5.918</td>
<td valign="top" align="center">0.017<xref ref-type="table-fn" rid="table-fn3">&#x002A;</xref></td>
</tr>
<tr>
<td valign="top" align="left">Composite type&#x2009;&#x00D7;&#x2009;polymerization temperature</td>
<td valign="top" align="center">6.216</td>
<td valign="top" align="center">1</td>
<td valign="top" align="center">6.216</td>
<td valign="top" align="center">0.412</td>
<td valign="top" align="center">0.523</td>
</tr>
<tr>
<td valign="top" align="left">Error</td>
<td valign="top" align="center">1,146.263</td>
<td valign="top" align="center">76</td>
<td valign="top" align="center">15.082</td>
<td valign="top" align="center"/>
<td valign="top" align="center"/>
</tr>
<tr>
<td valign="top" align="left">Total</td>
<td valign="top" align="center">9,335.030</td>
<td valign="top" align="center">80</td>
<td valign="top" align="center"/>
<td valign="top" align="center"/>
<td valign="top" align="center"/>
</tr>
<tr>
<td valign="top" align="left">Corrected total</td>
<td valign="top" align="center">3,426.827</td>
<td valign="top" align="center">79</td>
<td valign="top" align="center"/>
<td valign="top" align="center"/>
<td valign="top" align="center"/>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="table-fn2"><label><sup>a</sup></label>
<p>R Squared&#x2009;&#x003D;&#x2009;0.666 (adjusted R Squared&#x2009;&#x003D;&#x2009;0.652).</p></fn>
<fn id="table-fn3"><label>&#x002A;</label>
<p>Significant at <italic>P</italic>&#x2009;&#x2264;&#x2009;0.05.</p></fn>
</table-wrap-foot>
</table-wrap>
</sec>
<sec id="s3b"><label>3.2</label><title>Surface gloss results</title>
<p>Three-way ANOVA results revealed significant interaction within and among the tested groups, <italic>P</italic>&#x2009;&#x003C;&#x2009;0.001 as shown in <xref ref-type="table" rid="T3">Table&#x00A0;3</xref>. Means and standard deviations of the surface gloss results are presented in <xref ref-type="table" rid="T4">Table&#x00A0;4</xref>. Initially, the FOB-NH group showed significantly higher gloss values (125.8&#x2009;&#x00B1;&#x2009;22.3) compared to the BB-NH group (58.3&#x2009;&#x00B1;&#x2009;11.6), <italic>P</italic>&#x2009;&#x003C;&#x2009;0.001. However, the BB-PH groups had a significantly higher gloss value (112.3&#x2009;&#x00B1;&#x2009;19.4) compared to the FOB-PH group (64.5&#x2009;&#x00B1;&#x2009;6.3), <italic>P</italic>&#x2009;&#x003C;&#x2009;0.001. After immersion in the Cola beverage, all the groups showed a significant reduction in gloss compared to their initial readings, <italic>P</italic>&#x2009;&#x003C;&#x2009;0.001, the highest values were recorded for FOB-PH (34.8&#x2009;&#x00B1;&#x2009;11.6) and BB-NH (34.4&#x2009;&#x00B1;&#x2009;12) with no significant difference between both, <italic>P</italic>&#x2009;&#x003D;&#x2009;0.94, followed by FOB-NH (22.8&#x2009;&#x00B1;&#x2009;3.7) and BB-PH (23.4&#x2009;&#x00B1;&#x2009;16.2) with no significant difference between both as well, <italic>P</italic>&#x2009;&#x003D;&#x2009;0.89.</p>
<table-wrap id="T3" position="float"><label>Table 3</label>
<caption><p>Three-way analysis of variance of the specimen&#x0027;s surface gloss (GU) as affected by the composite type, the pre-polymerization temperature and the immersion in cola.</p></caption>
<table frame="hsides" rules="groups">
<colgroup>
<col align="left"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
</colgroup>
<thead>
<tr>
<th valign="top" align="left">Source</th>
<th valign="top" align="center">Type III sum of squares</th>
<th valign="top" align="center">Df</th>
<th valign="top" align="center">Mean square</th>
<th valign="top" align="center">F</th>
<th valign="top" align="center"><italic>P</italic>- value</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Corrected model</td>
<td valign="top" align="center">221,920.094<xref ref-type="table-fn" rid="table-fn4"><sup>a</sup></xref></td>
<td valign="top" align="center">7</td>
<td valign="top" align="center">31,702.871</td>
<td valign="top" align="center">158.318</td>
<td valign="top" align="center">0.000<xref ref-type="table-fn" rid="table-fn5">&#x002A;</xref></td>
</tr>
<tr>
<td valign="top" align="left">Intercept</td>
<td valign="top" align="center">567,440.041</td>
<td valign="top" align="center">1</td>
<td valign="top" align="center">567,440.041</td>
<td valign="top" align="center">2,833.687</td>
<td valign="top" align="center">0.000<xref ref-type="table-fn" rid="table-fn5">&#x002A;</xref></td>
</tr>
<tr>
<td valign="top" align="left">Composite type</td>
<td valign="top" align="center">941.870</td>
<td valign="top" align="center">1</td>
<td valign="top" align="center">941.870</td>
<td valign="top" align="center">4.704</td>
<td valign="top" align="center">0.032<xref ref-type="table-fn" rid="table-fn5"><bold>&#x002A;</bold></xref></td>
</tr>
<tr>
<td valign="top" align="left">Polymerization temperature</td>
<td valign="top" align="center">101.761</td>
<td valign="top" align="center">1</td>
<td valign="top" align="center">101.761</td>
<td valign="top" align="center">0.508</td>
<td valign="top" align="center">0.477</td>
</tr>
<tr>
<td valign="top" align="left">Cola immersion</td>
<td valign="top" align="center">150,638.802</td>
<td valign="top" align="center">1</td>
<td valign="top" align="center">150,638.802</td>
<td valign="top" align="center">752.261</td>
<td valign="top" align="center">0.000<xref ref-type="table-fn" rid="table-fn5">&#x002A;</xref></td>
</tr>
<tr>
<td valign="top" align="left">Composite type&#x2009;&#x00D7;&#x2009;polymerization temperature</td>
<td valign="top" align="center">21,330.542</td>
<td valign="top" align="center">1</td>
<td valign="top" align="center">21,330.542</td>
<td valign="top" align="center">106.521</td>
<td valign="top" align="center">0.000<xref ref-type="table-fn" rid="table-fn5"><bold>&#x002A;</bold></xref></td>
</tr>
<tr>
<td valign="top" align="left">Composite type&#x2009;&#x00D7;&#x2009;cola immersion</td>
<td valign="top" align="center">988.036</td>
<td valign="top" align="center">1</td>
<td valign="top" align="center">988.036</td>
<td valign="top" align="center">4.934</td>
<td valign="top" align="center">0.028<xref ref-type="table-fn" rid="table-fn5">&#x002A;</xref></td>
</tr>
<tr>
<td valign="top" align="left">Polymerization temperature&#x2009;&#x00D7;&#x2009;cola immersion</td>
<td valign="top" align="center">170.982</td>
<td valign="top" align="center">1</td>
<td valign="top" align="center">170.982</td>
<td valign="top" align="center">0.854</td>
<td valign="top" align="center">0.357</td>
</tr>
<tr>
<td valign="top" align="left">Composite type x polymerization temperature&#x2009;&#x00D7;&#x2009;cola immersion</td>
<td valign="top" align="center">47,748.100</td>
<td valign="top" align="center">1</td>
<td valign="top" align="center">47,748.100</td>
<td valign="top" align="center">238.445</td>
<td valign="top" align="center">0.000<xref ref-type="table-fn" rid="table-fn5">&#x002A;</xref></td>
</tr>
<tr>
<td valign="top" align="left">Error</td>
<td valign="top" align="center">30,437.685</td>
<td valign="top" align="center">152</td>
<td valign="top" align="center">200.248</td>
<td valign="top" align="center"/>
<td valign="top" align="center"/>
</tr>
<tr>
<td valign="top" align="left">Total</td>
<td valign="top" align="center">819,797.820</td>
<td valign="top" align="center">160</td>
<td valign="top" align="center"/>
<td valign="top" align="center"/>
<td valign="top" align="center"/>
</tr>
<tr>
<td valign="top" align="left">Corrected total</td>
<td valign="top" align="center">252,357.779</td>
<td valign="top" align="center">159</td>
<td valign="top" align="center"/>
<td valign="top" align="center"/>
<td valign="top" align="center"/>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="table-fn4"><label><sup>a</sup></label>
<p>R Squared&#x2009;&#x003D;&#x2009;0.879 (adjusted R Squared&#x2009;&#x003D;&#x2009;0.874).</p></fn>
<fn id="table-fn5"><label>&#x002A;</label>
<p>Significant at <italic>P</italic>&#x2009;&#x2264;&#x2009;0.05.</p></fn>
</table-wrap-foot>
</table-wrap>
<table-wrap id="T4" position="float"><label>Table 4</label>
<caption><p>The surface gloss (GU) means and standard deviations of the materials utilized in the current study.</p></caption>
<table frame="hsides" rules="groups">
<colgroup>
<col align="left"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
</colgroup>
<thead>
<tr>
<th valign="top" align="left">Materials/temperature</th>
<th valign="top" align="center" colspan="2">Not pre-heated (NH)</th>
<th valign="top" align="center" colspan="2">Pre-heated (PH)</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left" rowspan="2">Beautifil-bulk restorative (BB)</td>
<td valign="top" align="center">Before immersion</td>
<td valign="top" align="center">After immersion</td>
<td valign="top" align="center">Before immersion</td>
<td valign="top" align="center">After immersion</td>
</tr>
<tr>
<td valign="top" align="center">58.3&#x2009;&#x00B1;&#x2009;(11.6)<sup>Aa</sup></td>
<td valign="top" align="center">34.4&#x2009;&#x00B1;&#x2009;(12)<sup>Ab</sup></td>
<td valign="top" align="center">112.3&#x2009;&#x00B1;&#x2009;(19.4)<sup>Ac</sup></td>
<td valign="top" align="center">23.4&#x2009;&#x00B1;&#x2009;(16.2)<sup>Ad</sup></td>
</tr>
<tr>
<td valign="top" align="left">Filtek one bulk-fill (FOB)</td>
<td valign="top" align="center">125.8&#x2009;&#x00B1;&#x2009;(22.3)<sup>Ba</sup></td>
<td valign="top" align="center">22.8&#x2009;&#x00B1;&#x2009;(3.7)<sup>Bb</sup></td>
<td valign="top" align="center">64.5&#x2009;&#x00B1;&#x2009;(6.3)<sup>Bc</sup></td>
<td valign="top" align="center">34.8&#x2009;&#x00B1;&#x2009;(11.6)<sup>Bd</sup></td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="table-fn6"><p>Different letters within columns and lines indicate statistically significant differences (<italic>p</italic>&#x2009;&#x003C;&#x2009;0.05). Lowercases represent linear differences while uppercases represent columnar differences.</p></fn>
</table-wrap-foot>
</table-wrap>
</sec>
<sec id="s3c"><label>3.3</label><title>Microhardness results</title>
<p>Three-way ANOVA revealed significant interaction within and among the tested groups (<italic>P</italic>&#x2009;&#x003C;&#x2009;0.001) as shown in <xref ref-type="table" rid="T5">Table&#x00A0;5</xref>. Means and standard deviations of the microhardness results are presented in <xref ref-type="table" rid="T6">Table&#x00A0;6</xref>. Comparing the effect of pre-polymerization temperature on BB: initially; the microhardness was significantly higher in PH group (53.2&#x2009;&#x00B1;&#x2009;9.7) than NH group (40.1&#x2009;&#x00B1;&#x2009;7.3), <italic>P</italic>&#x2009;&#x003D;&#x2009;0.001. The microhardness of the same material significantly reduced after immersion in the acidic beverage in both groups compared to their initial readings <italic>P</italic>&#x2009;&#x003C;&#x2009;0.001, to be (30.9&#x2009;&#x00B1;&#x2009;8.5) for BB-NH group which was not significantly different from BB-PH group (26.1&#x2009;&#x00B1;&#x2009;13.3), <italic>P</italic>&#x2009;&#x003D;&#x2009;0.23. The microhardness of FOB was significantly higher in all the groups than BB, <italic>P</italic>&#x2009;&#x003C;&#x2009;0.001. Comparing the effect of pre-polymerization temperature on FOB: initially the microhardness of FOB-PH group (68.5&#x2009;&#x00B1;&#x2009;10.4) was significantly higher than NH group (51.8&#x2009;&#x00B1;&#x2009;4.5), <italic>P</italic>&#x2009;&#x003D;&#x2009;0.001, however after immersion in the acidic beverage, both groups showed significant reduction in microhardness, <italic>P</italic>&#x2009;&#x003C;&#x2009;0.001, to be (44.9&#x2009;&#x00B1;&#x2009;6.1) for FOB-PH, and (42.9&#x2009;&#x00B1;&#x2009;8.3) for FOB-NH, with no significant difference between both groups, <italic>P</italic>&#x2009;&#x003D;&#x2009;0.63.</p>
<table-wrap id="T5" position="float"><label>Table 5</label>
<caption><p>Three-way analysis of variance of the specimen&#x0027;s Vickers microhardness (VHN) as affected by the composite type, the pre-polymerization temperature and the immersion in cola.</p></caption>
<table frame="hsides" rules="groups">
<colgroup>
<col align="left"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
</colgroup>
<thead>
<tr>
<th valign="top" align="left">Source</th>
<th valign="top" align="center">Type III sum of squares</th>
<th valign="top" align="center">Df</th>
<th valign="top" align="center">Mean square</th>
<th valign="top" align="center">F</th>
<th valign="top" align="center"><italic>P</italic>- value</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Corrected model</td>
<td valign="top" align="center">24,957.296<xref ref-type="table-fn" rid="table-fn7"><sup>a</sup></xref></td>
<td valign="top" align="center">7</td>
<td valign="top" align="center">3,565.328</td>
<td valign="top" align="center">47.732</td>
<td valign="top" align="center">0.000<xref ref-type="table-fn" rid="table-fn8">&#x002A;</xref></td>
</tr>
<tr>
<td valign="top" align="left">Intercept</td>
<td valign="top" align="center">320,945.434</td>
<td valign="top" align="center">1</td>
<td valign="top" align="center">320,945.434</td>
<td valign="top" align="center">4,296.770</td>
<td valign="top" align="center">0.000<xref ref-type="table-fn" rid="table-fn8">&#x002A;</xref></td>
</tr>
<tr>
<td valign="top" align="left">Composite type</td>
<td valign="top" align="center">8,340.255</td>
<td valign="top" align="center">1</td>
<td valign="top" align="center">8,340.255</td>
<td valign="top" align="center">111.658</td>
<td valign="top" align="center">0.000<xref ref-type="table-fn" rid="table-fn8">&#x002A;</xref></td>
</tr>
<tr>
<td valign="top" align="left">Polymerization temperature</td>
<td valign="top" align="center">1,822.635</td>
<td valign="top" align="center">1</td>
<td valign="top" align="center">1,822.635</td>
<td valign="top" align="center">24.401</td>
<td valign="top" align="center">0.000<xref ref-type="table-fn" rid="table-fn8">&#x002A;</xref></td>
</tr>
<tr>
<td valign="top" align="left">Cola immersion</td>
<td valign="top" align="center">11,798.882</td>
<td valign="top" align="center">1</td>
<td valign="top" align="center">11,798.882</td>
<td valign="top" align="center">157.962</td>
<td valign="top" align="center">0.000<xref ref-type="table-fn" rid="table-fn8">&#x002A;</xref></td>
</tr>
<tr>
<td valign="top" align="left">Composite type&#x2009;&#x00D7;&#x2009;polymerization temperature</td>
<td valign="top" align="center">265.277</td>
<td valign="top" align="center">1</td>
<td valign="top" align="center">265.277</td>
<td valign="top" align="center">3.551</td>
<td valign="top" align="center">0.061</td>
</tr>
<tr>
<td valign="top" align="left">Composite type&#x2009;&#x00D7;&#x2009;cola immersion</td>
<td valign="top" align="center">36.119</td>
<td valign="top" align="center">1</td>
<td valign="top" align="center">36.119</td>
<td valign="top" align="center">0.484</td>
<td valign="top" align="center">0.488</td>
</tr>
<tr>
<td valign="top" align="left">Polymerization temperature&#x2009;&#x00D7;&#x2009;Cola immersion</td>
<td valign="top" align="center">2,670.119</td>
<td valign="top" align="center">1</td>
<td valign="top" align="center">2,670.119</td>
<td valign="top" align="center">35.747</td>
<td valign="top" align="center">0.000<xref ref-type="table-fn" rid="table-fn8">&#x002A;</xref></td>
</tr>
<tr>
<td valign="top" align="left">Composite type&#x2009;&#x00D7;&#x2009;polymerization temperature&#x2009;&#x00D7;&#x2009;cola immersion</td>
<td valign="top" align="center">24.010</td>
<td valign="top" align="center">1</td>
<td valign="top" align="center">24.010</td>
<td valign="top" align="center">0.321</td>
<td valign="top" align="center">0.572</td>
</tr>
<tr>
<td valign="top" align="left">Error</td>
<td valign="top" align="center">11,353.575</td>
<td valign="top" align="center">152</td>
<td valign="top" align="center">74.695</td>
<td valign="top" align="center"/>
<td valign="top" align="center"/>
</tr>
<tr>
<td valign="top" align="left">Total</td>
<td valign="top" align="center">357,256.305</td>
<td valign="top" align="center">160</td>
<td valign="top" align="center"/>
<td valign="top" align="center"/>
<td valign="top" align="center"/>
</tr>
<tr>
<td valign="top" align="left">Corrected total</td>
<td valign="top" align="center">36,310.871</td>
<td valign="top" align="center">159</td>
<td valign="top" align="center"/>
<td valign="top" align="center"/>
<td valign="top" align="center"/>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="table-fn7"><label><sup>a</sup></label>
<p>R Squared&#x2009;&#x003D;&#x2009;0.687 (adjusted R Squared&#x2009;&#x003D;&#x2009;0.673).</p></fn>
<fn id="table-fn8"><label>&#x002A;</label>
<p>Significant at <italic>P</italic>&#x2009;&#x2264;&#x2009;0.05.</p></fn>
</table-wrap-foot>
</table-wrap>
<table-wrap id="T6" position="float"><label>Table 6</label>
<caption><p>The vickers microhardness (VHN) means and standard deviations of the materials utilized in the current study.</p></caption>
<table frame="hsides" rules="groups">
<colgroup>
<col align="left"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
</colgroup>
<thead>
<tr>
<th valign="top" align="left">Materials/temperature</th>
<th valign="top" align="center" colspan="2">Not pre-heated (NH)</th>
<th valign="top" align="center" colspan="2">Pre-heated (PH)</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left" rowspan="2">Beautifil bulk (BB)</td>
<td valign="top" align="center">Before immersion</td>
<td valign="top" align="center">After immersion</td>
<td valign="top" align="center">Before immersion</td>
<td valign="top" align="center">After immersion</td>
</tr>
<tr>
<td valign="top" align="center">40.1&#x2009;&#x00B1;&#x2009;(7.3)<sup>Aa</sup></td>
<td valign="top" align="center">30.9&#x2009;&#x00B1;&#x2009;(8.5)<sup>Ab</sup></td>
<td valign="top" align="center">53.2&#x2009;&#x00B1;&#x2009;(9.7)<sup>Ac</sup></td>
<td valign="top" align="center">26.1&#x2009;&#x00B1;&#x2009;(13.3)<sup>Ab</sup></td>
</tr>
<tr>
<td valign="top" align="left">Filtek one bulk fill (FOB)</td>
<td valign="top" align="center">51.8&#x2009;&#x00B1;&#x2009;(4.5)<sup>Ba</sup></td>
<td valign="top" align="center">42.9&#x2009;&#x00B1;&#x2009;(8.3)<sup>Bb</sup></td>
<td valign="top" align="center">68.5&#x2009;&#x00B1;&#x2009;(10.4)<sup>Bc</sup></td>
<td valign="top" align="center">44.9&#x2009;&#x00B1;&#x2009;(6.1)<sup>Bb</sup></td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="table-fn9"><p>Different letters within columns and lines indicate statistically significant differences (<italic>p</italic>&#x2009;&#x003C;&#x2009;0.05). Lowercases represent linear differences while uppercases represent columnar differences.</p></fn>
</table-wrap-foot>
</table-wrap>
</sec>
</sec>
<sec id="s4" sec-type="discussion"><label>4</label><title>Discussion</title>
<p>The current <italic>in vitro</italic> study investigated the effect of a carbonated Cola beverage on the color stability, surface gloss and microhardness of two bulk-fill composite resins in preheated and non-preheated conditions before their polymerization. The first and third null hypotheses were rejected due to significant differences in the tested properties between the two resin composites and the impact of the carbonated beverage on all properties. The second null hypothesis was partially rejected, as preheating had no significant effect on the color change of BB.</p>
<p>The two investigated bulk-fill restorative materials in the current study were selected as they have different formulations both in their organic resin matrix and inorganic filler, they can be used in anterior and posterior restorations according to their manufacturer&#x0027;s claims. Beautifil-Bulk restorative is based on surface pre-reacted glass (S-PRG) fillers technology which imparts sustained fluoride release with an anti-plaque effect, this makes it beneficial for cases with high caries risk due to its ability to minimize secondary caries formation. Filtek One bulk-fill contains innovative monomers that reduce shrinkage and shrinkage stress, they also possess nano-&#xFB01;ller technology which provides superior aesthetic properties. Both composites also have different depth of cure levels, 4 and 5&#x2005;mm respectively, thus they have a wide range of applications among dental practitioners.</p>
<p>Preheating of the bulk-fill composites was compared to room temperature polymerization in the current study since it became a popular technique and gained attention lately. The flow of composite polymers can be enhanced by increasing their temperature, as demonstrated by recent literature (<xref ref-type="bibr" rid="B7">7</xref>). Some of the potential advantages of composite preheating include enhanced marginal adaptation, better handling, and a higher degree of monomer conversion. A previous study by Kampanas (<xref ref-type="bibr" rid="B28">28</xref>) found that the average preheating temperature of bulk-fill composites which was considered safe and not harmful to the pulp tissues was between the range of 54&#x00B0;C and 68&#x00B0;C, thus, the preheating temperature in the current investigation was set to 68&#x00B0;C to maximize the benefits of the preheating technique.</p>
<p>Another critical factor to consider when preheating is the sufficient time to achieve optimal flow and enhance the properties of the restorative material. Previous studies that referenced the required time for material heating revealed a wide range of minimum and maximum times. Nevertheless, a clinical time of approximately 15&#x2005;min is considered reasonable, as per the findings of Mohammadi, et al., and Karacan and Ozyurt (<xref ref-type="bibr" rid="B29">29</xref>, <xref ref-type="bibr" rid="B30">30</xref>). Accordingly, 15&#x2005;min of preheating time was considered in the current investigation.</p>
<p>It is crucial to ascertain whether the behaviour of the investigated materials has clinical implications and to consider its clinical acceptability during function. Therefore, the color stability results in the current study were statistically analyzed to assess the significant differences between groups, besides, it was further assessed based on the 50:50&#x0025; acceptability threshold (AT) and the perceptibility threshold (PT) in CIEDE2000 which were 0.8 and 1.8, respectively, as reported by Paravina, et al. (<xref ref-type="bibr" rid="B31">31</xref>) and as aligned with ISO standards (<xref ref-type="bibr" rid="B25">25</xref>). The susceptibility of the composite resins to staining may be related to their hydrophilicity, the degree of conversion, as well as to the water sorption of the resin matrix (<xref ref-type="bibr" rid="B16">16</xref>, <xref ref-type="bibr" rid="B32">32</xref>). Although the color change of both tested materials was beyond the 50/50&#x0025; acceptability limit (&#x003E;1.8), the color change of BB composite was significantly higher than FOB in both preheated in non-preheated states, this may be related to the difference in resin matrix composition between both materials. While both composites contain UDMA, which may reduce hydrophilicity and water absorption thus enhancing the color stability of composite resins, BB contains the more hydrophilic monomers Bis-GMA and TEGDMA, which are reported to increase the discoloration of composites by Ren, et al. (<xref ref-type="bibr" rid="B33">33</xref>), and Ozera, et al. (<xref ref-type="bibr" rid="B16">16</xref>). Moreover, BB is a bulk-fill form of giomer composites, representing a distinct category of bioactive resin-based materials capable of releasing fluoride as a preventive mechanism. However, the fluoride-release process may potentially create voids within the resin matrix, which in turn can reduce color stability due to enhanced pigment retention (<xref ref-type="bibr" rid="B34">34</xref>). Consequently, a more significant color shift with the exposure to the Cola beverage occurred in BB composite. The presence of these hydrophilic monomers and the bioactive characteristics also explain the current finding that preheating of composites was not able to stabilize the color of BB, this finding is in line with the study by Daneshpooy, et al, who found a significant color change of giomer composite after preheating in tea solution compared to microhybrid and nanohybrid composites (<xref ref-type="bibr" rid="B35">35</xref>). On the other hand, preheating of FOB in the current study improved it&#x0027;s the color stability after the Cola beverage attack, this is probably due to the presence of the unique additive fragmentation monomer (AFM), which increases the formation of cross-links between adjacent polymer chains, the preheating seems to improve the reactivity of this monomer and increase the degree of conversion which in turn improves the color stability by reducing the free monomer chains exposed to the colorant solution as reported in studies by Sousa, et al. (<xref ref-type="bibr" rid="B36">36</xref>) and Darabi, et al. (<xref ref-type="bibr" rid="B37">37</xref>). The current study result, however, is not in line with a study by Abdulmajeed, et al. (<xref ref-type="bibr" rid="B22">22</xref>) who reported in their study that preheating had no effect on stabilizing the color of the FOB composite, probably due to the strong staining potential of the coffee utilized in their study (<xref ref-type="bibr" rid="B13">13</xref>).</p>
<p>Surface gloss is an optical feature that is determined by the intensity of light reflection. The angle of incident light, the refractive index of the material components, and surface features are several elements that influence gloss (<xref ref-type="bibr" rid="B38">38</xref>). This study employed a 60&#x00B0; angle of incident light as per ISO 2813:2014 standards for medium gloss materials (<xref ref-type="bibr" rid="B26">26</xref>), rendering the gloss values contingent upon the surface topography and the material&#x0027;s refractive index. Irregular surface topography disperses light rather than reflecting it, hence diminishing the gloss value (<xref ref-type="bibr" rid="B39">39</xref>). There is no definitive threshold for gloss values of dental composites; however, it is advised to maintain a gloss value within the 40&#x2013;60&#x2005;GU range (<xref ref-type="bibr" rid="B40">40</xref>).</p>
<p>A recently published systematic review concluded that surface gloss is a reliable indicator for evaluating the effectiveness of finishing and polishing procedures on composite resin surfaces, as it directly correlates with surface roughness (<xref ref-type="bibr" rid="B41">41</xref>). Moreover, previous studies have demonstrated that the smoothest composite surfaces are obtained when polymerized against Mylar strips, without undergoing mechanical finishing (<xref ref-type="bibr" rid="B42">42</xref>, <xref ref-type="bibr" rid="B43">43</xref>). In line with this evidence, the specimens in the current study were polymerized against polyester celluloid strips without additional finishing or polishing. This approach was intended to eliminate operator-dependent variability associated with polishing procedures, ensuring that gloss measurements reflect the intrinsic surface characteristics of the composite materials in their preheated and non-preheated states, thereby revealing their baseline performance without alterations induced by polishing. In the current study, both materials exhibited satisfactory gloss values before the immersion in Cola beverage, with FOB showing superior gloss compared to BB, this may be attributed to the difference in filler load as well as the filler size and distribution in both materials, FOB filler is composed of agglomerated and non-agglomerated nanosized filler with total volume of 58.4&#x0025; which is less than the 74.5&#x0025; SPG-R filler of BB. It was reported in previous studies by Alhassan, et al., and (<xref ref-type="bibr" rid="B44">44</xref>) that composites having a filler size between 5 and 20&#x2005;nm are associated with an increase in gloss and light reflection, as these fillers are smaller than the visible light 400&#x2013;800&#x2005;nm wavelength. The high filler loading is also associated with less degree of conversion as suggested by Dionysopoulos, et al. (<xref ref-type="bibr" rid="B45">45</xref>) and Bucuta and Ilie (<xref ref-type="bibr" rid="B46">46</xref>), and this explains the improved gloss values of BB composites after preheating, which can be attributed to the improvement in the degree of conversion of the resin matrix secondary to its preheating. Although preheating reduced the gloss values of FOB, its gloss values remained clinically acceptable, this reduction may be related to stress build-up within the resin matrix secondary to the fastened polymerization rate after preheating as reported in Deb, et al. (<xref ref-type="bibr" rid="B21">21</xref>), and El-Korashy (<xref ref-type="bibr" rid="B47">47</xref>) studies, which may alter the bonding between the filler particles and resin matrix, thus changing the light reflection and subsequently reducing the surface gloss. On the Other hand, the gloss values reduced dramatically to be clinically unacceptable in all groups upon Cola exposure, which is in line with previous studies by Zovko, et al. (<xref ref-type="bibr" rid="B48">48</xref>) and Ozera, et al. (<xref ref-type="bibr" rid="B16">16</xref>). Such decrease in gloss is thought to be due to the presence of phosphoric acid in the composition of the Cola drink, which softens the organic matrix and thus leads to a change in light refraction and consequently a decrease in surface gloss.</p>
<p>The microhardness values in the current study was generally material dependent, the higher VHN recorded for FOB in all groups compared to BB is more likely related to the presence of the nano-sized filler particles which reduces the interstitial spaces, thus improving the surface hardness as reported in a study by Yap, et al. (<xref ref-type="bibr" rid="B49">49</xref>). The preheating showed a significant increase in microhardness of both tested composite resins in the current investigation compared to non-preheated groups without the acidic challenge, this finding is in line with previous studies (<xref ref-type="bibr" rid="B50">50</xref>&#x2013;<xref ref-type="bibr" rid="B53">53</xref>). The degree of conversion of carbon double bonds in the composite resin matrix is often reflected in its hardness values, thus increased hardness following preheating is highly related to the improvement in the degree of conversion and therefore greater cross-linking in the monomer chains (<xref ref-type="bibr" rid="B54">54</xref>). According to Trujillo, et al. (<xref ref-type="bibr" rid="B55">55</xref>), and Daronch, et al. (<xref ref-type="bibr" rid="B56">56</xref>) the rate of monomer-to-polymer conversion can be enhanced by warming a composite resin at biologically compatible conditions. However, a significant reduction in microhardness values occurred in both materials after exposure to the Cola drink in the preheated and non-preheated state, the deterioration effect of acidic drinks on composites microhardness is in line with Borges, et al. (<xref ref-type="bibr" rid="B17">17</xref>), and Poggio, et al. (<xref ref-type="bibr" rid="B57">57</xref>), studies. This is more likely due to softening of the organic matrix by the action of phosphoric acid on of both composites, hence changing the bonding between the silane coupling agent and filler particles, however, the reduction in hardness was less in FOB, probably due to its harder zirconia filler content compared to the surface pre-reacted glass filler (SPG-R) in BB restorative composite. Besides, the inclusion of nanoclusters alongside nanoparticles in FOB filler diminishes the interstitial space, hence enhancing the physical properties and the surface hardness.</p>
<p>The findings of the current study are limited to the characteristics of <italic>in vitro</italic> studies, some oral environmental conditions were not included, such as the change in intraoral temperature, the effect of other beverages and the diluent effect of saliva. Future research should explore a broader range of preheating temperatures and investigate the effects of different beverages on composite materials. Additionally, further studies are recommended to assess other clinically relevant outcomes such as mechanical properties, and the long-term durability of preheated bulk-fill composites, particularly after thermal cycling and under clinical conditions.</p>
</sec>
<sec id="s5" sec-type="conclusions"><label>5</label><title>Conclusions</title>
<p>Given the constraints of the present studies, it can be concluded that preheating improved the color stability of FOB and the gloss of BB, it also improved the microhardness of both bulk-fill composites. Conversely, exposure to Cola adversely affected all properties, resulting in clinically unacceptable color alterations.</p>
</sec>
</body>
<back>
<sec id="s6" sec-type="data-availability"><title>Data availability statement</title>
<p>The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.</p>
</sec>
<sec id="s7" sec-type="author-contributions"><title>Author contributions</title>
<p>NF: Conceptualization, Formal analysis, Methodology, Writing &#x2013; review &#x0026; editing. AA: Investigation, Writing &#x2013; original draft. OA: Investigation, Writing &#x2013; original draft. OM: Conceptualization, Methodology, Supervision, Writing &#x2013; review &#x0026; editing.</p>
</sec>
<sec id="s8" sec-type="funding-information"><title>Funding</title>
<p>The author(s) declare that financial support was received for the research and/or publication of this article. The research presented in this article was conducted by the authors while they were affiliated with Ras Al-Khaimah Medical and Health Sciences University and Ajman University of Science and Technology. Research facilities and the tested materials were provided by these institutions.</p>
</sec>
<sec id="s9" sec-type="COI-statement"><title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec id="s10" sec-type="ai-statement"><title>Generative AI statement</title>
<p>The author(s) declare that no Generative AI was used in the creation of this manuscript.</p>
</sec>
<sec id="s11" sec-type="disclaimer"><title>Publisher&#x0027;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ref-list><title>References</title>
<ref id="B1"><label>1.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pizzolotto</surname><given-names>L</given-names></name><name><surname>Moraes</surname><given-names>RR</given-names></name></person-group>. <article-title>Resin composites in posterior teeth: clinical performance and direct restorative techniques</article-title>. <source>Dent J</source>. (<year>2022</year>) <volume>10</volume>(<issue>12</issue>):<fpage>222</fpage>. <pub-id pub-id-type="doi">10.3390/dj10120222</pub-id></citation></ref>
<ref id="B2"><label>2.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Boaro</surname><given-names>LCC</given-names></name><name><surname>Lopes</surname><given-names>DP</given-names></name><name><surname>de Souza</surname><given-names>ASC</given-names></name><name><surname>Nakano</surname><given-names>EL</given-names></name><name><surname>Perez</surname><given-names>MDA</given-names></name><name><surname>Pfeifer</surname><given-names>CS</given-names></name><etal/></person-group> <article-title>Clinical performance and chemical-physical properties of bulk-fill composite resin&#x2014;a systematic review and meta-analysis</article-title>. <source>Dent Mater</source>. (<year>2019</year>) <volume>35</volume>(<issue>10</issue>):<fpage>e249</fpage>&#x2013;<lpage>64</lpage>. <pub-id pub-id-type="doi">10.1016/j.dental.2019.07.007</pub-id><pub-id pub-id-type="pmid">31421957</pub-id></citation></ref>
<ref id="B3"><label>3.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lima</surname><given-names>RBW</given-names></name><name><surname>Troconis</surname><given-names>CCM</given-names></name><name><surname>Moreno</surname><given-names>MBP</given-names></name><name><surname>Murillo-G&#x00F3;mez</surname><given-names>F</given-names></name><name><surname>De Goes</surname><given-names>MF</given-names></name></person-group>. <article-title>Depth of cure of bulk-fill resin composites: a systematic review</article-title>. <source>J Esthet Restor Dent</source><italic>.</italic> (<year>2018</year>) <volume>30</volume>(<issue>6</issue>):<fpage>492</fpage>&#x2013;<lpage>501</lpage>. <pub-id pub-id-type="doi">10.1111/jerd.12394</pub-id><pub-id pub-id-type="pmid">30375146</pub-id></citation></ref>
<ref id="B4"><label>4.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Floriani</surname><given-names>F</given-names></name><name><surname>Jurado</surname><given-names>CA</given-names></name><name><surname>Madhu</surname><given-names>N</given-names></name><name><surname>Lackey</surname><given-names>MA</given-names></name><name><surname>Azpiazu-Flores</surname><given-names>FX</given-names></name><name><surname>Lopes</surname><given-names>GC</given-names></name></person-group>. <article-title>Color stability of bulk-fill flowable resin composites after artificial ageing</article-title>. <source>Dent J</source><italic>.</italic> (<year>2024</year>) <volume>12</volume>(<issue>11</issue>):<fpage>350</fpage>. <pub-id pub-id-type="doi">10.3390/dj12110350</pub-id></citation></ref>
<ref id="B5"><label>5.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jafarpour</surname><given-names>D</given-names></name><name><surname>Ferooz</surname><given-names>R</given-names></name><name><surname>Ferooz</surname><given-names>M</given-names></name><name><surname>Bagheri</surname><given-names>R</given-names></name></person-group>. <article-title>Physical and mechanical properties of bulk-fill, conventional, and flowable resin composites stored dry and wet</article-title>. <source>Int J Dent</source>. (<year>2022</year>) <volume>2022</volume>:<fpage>7946239</fpage>. <pub-id pub-id-type="doi">10.1155/2022/7946239</pub-id><pub-id pub-id-type="pmid">35186087</pub-id></citation></ref>
<ref id="B6"><label>6.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Elshazly</surname><given-names>TM</given-names></name><name><surname>Bourauel</surname><given-names>C</given-names></name><name><surname>Sherief</surname><given-names>DI</given-names></name><name><surname>El-Korashy</surname><given-names>DI</given-names></name></person-group>. <article-title>Evaluation of two resin composites having different matrix compositions</article-title>. <source>Dent J</source>. (<year>2020</year>) <volume>8</volume>(<issue>3</issue>):<fpage>76</fpage>. <pub-id pub-id-type="doi">10.3390/dj8030076</pub-id></citation></ref>
<ref id="B7"><label>7.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lopes</surname><given-names>LCP</given-names></name><name><surname>Terada</surname><given-names>RSS</given-names></name><name><surname>Tsuzuki</surname><given-names>FM</given-names></name><name><surname>Giannini</surname><given-names>M</given-names></name><name><surname>Hirata</surname><given-names>R</given-names></name></person-group>. <article-title>Heating and preheating of dental restorative materials&#x2014;a systematic review</article-title>. <source>Clin Oral Investig</source>. (<year>2020</year>) <volume>24</volume>:<fpage>4225</fpage>&#x2013;<lpage>35</lpage>. <pub-id pub-id-type="doi">10.1007/s00784-020-03637-2</pub-id><pub-id pub-id-type="pmid">33083851</pub-id></citation></ref>
<ref id="B8"><label>8.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Taub&#x00F6;ck</surname><given-names>TT</given-names></name><name><surname>Tarle</surname><given-names>Z</given-names></name><name><surname>Marovic</surname><given-names>D</given-names></name><name><surname>Attin</surname><given-names>T</given-names></name></person-group>. <article-title>Pre-heating of high-viscosity bulk-fill resin composites: effects on shrinkage force and monomer conversion</article-title>. <source>J Dent</source><italic>.</italic> (<year>2015</year>) <volume>43</volume>(<issue>11</issue>):<fpage>1358</fpage>&#x2013;<lpage>64</lpage>. <pub-id pub-id-type="doi">10.1016/j.jdent.2015.07.014</pub-id></citation></ref>
<ref id="B9"><label>9.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mundim</surname><given-names>FM</given-names></name><name><surname>Garcia</surname><given-names>LdFR</given-names></name><name><surname>Cruvinel</surname><given-names>DR</given-names></name><name><surname>Lima</surname><given-names>FA</given-names></name><name><surname>Bachmann</surname><given-names>L</given-names></name><name><surname>Pires-de</surname><given-names>FdCP</given-names></name></person-group>. <article-title>Color stability, opacity, and degree of conversion of pre-heated composites</article-title>. <source>J Dent</source><italic>.</italic> (<year>2011</year>) <volume>39</volume>:<fpage>e25</fpage>&#x2013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1016/j.jdent.2010.12.001</pub-id><pub-id pub-id-type="pmid">21163324</pub-id></citation></ref>
<ref id="B10"><label>10.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Shamszadeh</surname><given-names>S</given-names></name><name><surname>Sheikh-Al-Eslamian</surname><given-names>SM</given-names></name><name><surname>Hasani</surname><given-names>E</given-names></name><name><surname>Abrandabadi</surname><given-names>AN</given-names></name><name><surname>Panahandeh</surname><given-names>N.</given-names></name></person-group> <article-title>Color stability of the bulk-fill composite resins with different thickness in response to coffee/water immersion</article-title>. <source>Int J Dent</source><italic>.</italic> (<year>2016</year>) <volume>2016</volume>:<fpage>7186140</fpage>. <pub-id pub-id-type="doi">10.1155/2016/7186140</pub-id><pub-id pub-id-type="pmid">27403163</pub-id></citation></ref>
<ref id="B11"><label>11.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zupo</surname><given-names>R</given-names></name><name><surname>Castellana</surname><given-names>F</given-names></name><name><surname>De Nucci</surname><given-names>S</given-names></name><name><surname>Dibello</surname><given-names>V</given-names></name><name><surname>Lozupone</surname><given-names>M</given-names></name><name><surname>Giannelli</surname><given-names>G</given-names></name><etal/></person-group> <article-title>Beverages consumption and oral health in the aging population: a systematic review</article-title>. <source>Front Nutr</source><italic>.</italic> (<year>2021</year>) <volume>8</volume>:<fpage>762383</fpage>. <pub-id pub-id-type="doi">10.3389/fnut.2021.762383</pub-id><pub-id pub-id-type="pmid">34778347</pub-id></citation></ref>
<ref id="B12"><label>12.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Farghal</surname><given-names>NS</given-names></name><name><surname>Awadalkreem</surname><given-names>F</given-names></name><name><surname>Abouelhonoud</surname><given-names>NA</given-names></name><name><surname>Khan</surname><given-names>RI</given-names></name></person-group>. <article-title>The gloss retention of esthetic restorations following simulated brushing with charcoal oral products: an in vitro study</article-title>. <source>J Contemp Dent Pract</source>. (<year>2024</year>) <volume>25</volume>(<issue>5</issue>):<fpage>473</fpage>&#x2013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.5005/jp-journals-10024-3692</pub-id><pub-id pub-id-type="pmid">39364847</pub-id></citation></ref>
<ref id="B13"><label>13.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Farghal</surname><given-names>NS</given-names></name><name><surname>Sheikh Debis</surname><given-names>MN</given-names></name><name><surname>Abou Baker</surname><given-names>T</given-names></name><name><surname>Mahmoud</surname><given-names>O</given-names></name></person-group>. <article-title>The influence of the new charcoal toothbrush and toothpaste on esthetic restoration properties</article-title>. <source>Int J Dent</source><italic>.</italic> (<year>2024</year>) <volume>2024</volume>:<fpage>4385524</fpage>. <pub-id pub-id-type="doi">10.1155/2024/4385524</pub-id></citation></ref>
<ref id="B14"><label>14.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Silva</surname><given-names>M-F</given-names></name><name><surname>Dias</surname><given-names>M-F</given-names></name><name><surname>Lins-Filho</surname><given-names>P-C</given-names></name><name><surname>Guimar&#x00E3;es</surname><given-names>R-P</given-names></name></person-group>. <article-title>Color stability of bulk-fill composite restorations</article-title>. <source>J Clin Exp Dent</source>. (<year>2020</year>) <volume>12</volume>(<issue>11</issue>):<fpage>e1086</fpage>. <pub-id pub-id-type="doi">10.4317/jced.57579</pub-id><pub-id pub-id-type="pmid">33262876</pub-id></citation></ref>
<ref id="B15"><label>15.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bilgili Can</surname><given-names>D</given-names></name><name><surname>&#x00D6;zarslan</surname><given-names>M</given-names></name></person-group>. <article-title>Evaluation of color stability and microhardness of contemporary bulk-fill composite resins with different polymerization properties</article-title>. <source>J Esthet Restor Dent</source>. (<year>2022</year>) <volume>34</volume>(<issue>6</issue>):<fpage>924</fpage>&#x2013;<lpage>32</lpage>. <pub-id pub-id-type="doi">10.1111/jerd.12879</pub-id><pub-id pub-id-type="pmid">35118802</pub-id></citation></ref>
<ref id="B16"><label>16.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ozera</surname><given-names>EH</given-names></name><name><surname>Pascon</surname><given-names>FM</given-names></name><name><surname>Correr</surname><given-names>AB</given-names></name><name><surname>Puppin-Rontani</surname><given-names>RM</given-names></name><name><surname>Castilho</surname><given-names>A</given-names></name><name><surname>Correr-Sobrinho</surname><given-names>L</given-names></name><etal/></person-group> <article-title>Color stability and gloss of esthetic restorative materials after chemical challenges</article-title>. <source>Braz Dent J</source>. (<year>2019</year>) <volume>30</volume>:<fpage>52</fpage>&#x2013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1590/0103-6440201902263</pub-id><pub-id pub-id-type="pmid">30864648</pub-id></citation></ref>
<ref id="B17"><label>17.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Borges</surname><given-names>MG</given-names></name><name><surname>Soares</surname><given-names>CJ</given-names></name><name><surname>Maia</surname><given-names>TS</given-names></name><name><surname>Bicalho</surname><given-names>AA</given-names></name><name><surname>Barbosa</surname><given-names>TP</given-names></name><name><surname>Costa</surname><given-names>HL</given-names></name><etal/></person-group> <article-title>Effect of acidic drinks on shade matching, surface topography, and mechanical properties of conventional and bulk-fill composite resins</article-title>. <source>J Prosthet Dent</source>. (<year>2019</year>) <volume>121</volume>(<issue>5</issue>):<fpage>868.e1</fpage>&#x2013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1016/j.prosdent.2019.02.006</pub-id><pub-id pub-id-type="pmid">31010591</pub-id></citation></ref>
<ref id="B18"><label>18.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Baroudi</surname><given-names>K</given-names></name><name><surname>Islam</surname><given-names>MS</given-names></name><name><surname>Awadalkreem</surname><given-names>F</given-names></name><name><surname>Hussain</surname><given-names>ZE</given-names></name><name><surname>Shaheen</surname><given-names>C</given-names></name><name><surname>Moreira</surname><given-names>PP</given-names></name><etal/></person-group> <article-title>Influence of acidic drinks and brushing on microhardness of restorative resin materials</article-title>. <source>Open Dent J</source>. (<year>2024</year>) <volume>18</volume>(<issue>1</issue>). <pub-id pub-id-type="doi">10.2174/0118742106348736241010105828</pub-id></citation></ref>
<ref id="B19"><label>19.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>El-Sayed</surname><given-names>HY</given-names></name><name><surname>Abdalla</surname><given-names>AI</given-names></name><name><surname>El-Ebiary</surname><given-names>MA</given-names></name><name><surname>El-Eraky</surname><given-names>M</given-names></name><name><surname>Farghal</surname><given-names>NA</given-names></name></person-group>. <article-title>The effects of two bleaching agents on the physico-mechanical properties of three resin-based restorative materials</article-title>. <source>Int J Clin Dent</source>. (<year>2009</year>):<fpage>69</fpage>.</citation></ref>
<ref id="B20"><label>20.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Theobaldo</surname><given-names>JD</given-names></name><name><surname>Aguiar</surname><given-names>FHB</given-names></name><name><surname>Pini</surname><given-names>NIP</given-names></name><name><surname>Lima</surname><given-names>DANL</given-names></name><name><surname>Liporoni</surname><given-names>PCS</given-names></name><name><surname>Catelan</surname><given-names>A</given-names></name></person-group>. <article-title>Effect of preheating and light-curing unit on physicochemical properties of a bulk-fill composite</article-title>. <source>Clin Cosmet Investig Dent</source><italic>.</italic> (<year>2017</year>):<fpage>39</fpage>&#x2013;<lpage>43</lpage>. <pub-id pub-id-type="doi">10.2147/CCIDE.S130803</pub-id><pub-id pub-id-type="pmid">28652817</pub-id></citation></ref>
<ref id="B21"><label>21.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Deb</surname><given-names>S</given-names></name><name><surname>Di Silvio</surname><given-names>L</given-names></name><name><surname>Mackler</surname><given-names>HE</given-names></name><name><surname>Millar</surname><given-names>BJ</given-names></name></person-group>. <article-title>Pre-warming of dental composites</article-title>. <source>Dent Mater</source>. (<year>2011</year>) <volume>27</volume>(<issue>4</issue>):<fpage>e51</fpage>&#x2013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1016/j.dental.2010.11.009</pub-id><pub-id pub-id-type="pmid">21145580</pub-id></citation></ref>
<ref id="B22"><label>22.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Abdulmajeed</surname><given-names>A</given-names></name><name><surname>Suliman</surname><given-names>A</given-names></name><name><surname>Selivany</surname><given-names>B</given-names></name><name><surname>Altitinchi</surname><given-names>A</given-names></name><name><surname>Sulaiman</surname><given-names>T</given-names></name></person-group>. <article-title>Wear and color stability of preheated bulk-fill and conventional resin composites</article-title>. <source>Oper Dent</source>. (<year>2022</year>) <volume>47</volume>(<issue>5</issue>):<fpage>585</fpage>&#x2013;<lpage>92</lpage>. <pub-id pub-id-type="doi">10.2341/21-077-L</pub-id><pub-id pub-id-type="pmid">36136611</pub-id></citation></ref>
<ref id="B23"><label>23.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sharma</surname><given-names>G</given-names></name><name><surname>Wu</surname><given-names>W</given-names></name><name><surname>Dalal</surname><given-names>EN</given-names></name></person-group>. <article-title>The CIEDE2000 color-difference formula: implementation notes, supplementary test data, and mathematical observations</article-title>. <source>Color Res Appl</source>. (<year>2005</year>) <volume>30</volume>(<issue>1</issue>):<fpage>21</fpage>&#x2013;<lpage>30</lpage>. <pub-id pub-id-type="doi">10.1002/col.20070</pub-id></citation></ref>
<ref id="B24"><label>24.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Paravina</surname><given-names>RD</given-names></name><name><surname>Ghinea</surname><given-names>R</given-names></name><name><surname>Herrera</surname><given-names>LJ</given-names></name><name><surname>Bona</surname><given-names>AD</given-names></name><name><surname>Igiel</surname><given-names>C</given-names></name><name><surname>Linninger</surname><given-names>M</given-names></name><etal/></person-group> <article-title>Color difference thresholds in dentistry</article-title>. <source>J Esthet Restor Dent</source>. (<year>2015</year>) <volume>27</volume>:<fpage>S1</fpage>&#x2013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1111/jerd.12149</pub-id><pub-id pub-id-type="pmid">25886208</pub-id></citation></ref>
<ref id="B25"><label>25.</label><citation citation-type="book"><collab>ISO/TR 28642</collab>. <source>Dentistry-Guidance on Colour Measurement</source>. <publisher-loc>Geneva</publisher-loc>: <publisher-name>International Standards Organization (ISO)</publisher-name> (<year>2016</year>) <volume>2</volume>:<fpage>1</fpage>&#x2013;<lpage>10</lpage>.</citation></ref>
<ref id="B26"><label>26.</label><citation citation-type="book"><collab>ISO 2813:2014</collab>. <source>Paints and Varnishes&#x2014;determination of Gloss Value at 20&#x00B0;, 60&#x00B0; and 85&#x00B0;</source>. <publisher-loc>Geneva</publisher-loc>: <publisher-name>International Organization for Standardization</publisher-name> (<year>2014</year>).</citation></ref>
<ref id="B27"><label>27.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ardu</surname><given-names>S</given-names></name><name><surname>Duc</surname><given-names>O</given-names></name><name><surname>Krejci</surname><given-names>I</given-names></name><name><surname>B&#x00E9;trisey</surname><given-names>E</given-names></name><name><surname>Di Bella</surname><given-names>E</given-names></name><name><surname>Daher</surname><given-names>R</given-names></name></person-group>. <article-title>Gloss retention of direct composites and corresponding CAD/CAM composite blocks</article-title>. <source>Clin Exp Dent Res</source><italic>.</italic> (<year>2022</year>) <volume>8</volume>(<issue>1</issue>):<fpage>282</fpage>&#x2013;<lpage>6</lpage>. <pub-id pub-id-type="doi">10.1002/cre2.505</pub-id><pub-id pub-id-type="pmid">34647425</pub-id></citation></ref>
<ref id="B28"><label>28.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Nikolaos-Stefanos</surname><given-names>K</given-names></name></person-group>. <article-title>Resin composite pre-heating&#x2013;a literature review of the laboratory results</article-title>. <source>Int J Oral Dent Health</source>. (<year>2018</year>) <volume>4</volume>(<issue>2</issue>):<fpage>074</fpage>. <pub-id pub-id-type="doi">10.23937/2469-5734/1510074</pub-id></citation></ref>
<ref id="B29"><label>29.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mohammadi</surname><given-names>N</given-names></name><name><surname>Jafari-Navimipour</surname><given-names>E</given-names></name><name><surname>Kimyai</surname><given-names>S</given-names></name><name><surname>Ajami</surname><given-names>A-A</given-names></name><name><surname>Bahari</surname><given-names>M</given-names></name><name><surname>Ansarin</surname><given-names>M</given-names></name><etal/></person-group> <article-title>Effect of pre-heating on the mechanical properties of silorane-based and methacrylate-based composites</article-title>. <source>J Clin Exp Dent</source><italic>.</italic> (<year>2016</year>) <volume>8</volume>(<issue>4</issue>):<fpage>e373</fpage>. <pub-id pub-id-type="doi">10.4317/jced.52807</pub-id><pub-id pub-id-type="pmid">27703604</pub-id></citation></ref>
<ref id="B30"><label>30.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Karacan</surname><given-names>AO</given-names></name><name><surname>Ozyurt</surname><given-names>P</given-names></name></person-group>. <article-title>Effect of preheated bulk-fill composite temperature on intrapulpal temperature increase in vitro</article-title>. <source>J Esthet Restor Dent</source>. (<year>2019</year>) <volume>31</volume>(<issue>6</issue>):<fpage>583</fpage>&#x2013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1111/jerd.12503</pub-id><pub-id pub-id-type="pmid">31194288</pub-id></citation></ref>
<ref id="B31"><label>31.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Paravina</surname><given-names>RD</given-names></name><name><surname>P&#x00E9;rez</surname><given-names>MM</given-names></name><name><surname>Ghinea</surname><given-names>R</given-names></name></person-group>. <article-title>Acceptability and perceptibility thresholds in dentistry: a comprehensive review of clinical and research applications</article-title>. <source>J Esthet Restor Dent</source><italic>.</italic> (<year>2019</year>) <volume>31</volume>(<issue>2</issue>):<fpage>103</fpage>&#x2013;<lpage>12</lpage>. <pub-id pub-id-type="doi">10.1111/jerd.12465</pub-id><pub-id pub-id-type="pmid">30891913</pub-id></citation></ref>
<ref id="B32"><label>32.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Farghal</surname><given-names>NS</given-names></name><name><surname>Awadalkreem</surname><given-names>F</given-names></name><name><surname>Dasnadi</surname><given-names>SP</given-names></name><name><surname>Habush</surname><given-names>S</given-names></name><name><surname>Hatab</surname><given-names>NA</given-names></name><name><surname>Harhash</surname><given-names>A</given-names></name></person-group>. <article-title>Staining susceptibility and the effect of different stain removal techniques on the optical properties of injectable composite resins</article-title>. <source>Front Oral Health</source>. (<year>2025</year>) <volume>6</volume>:<fpage>1556155</fpage>. <pub-id pub-id-type="doi">10.3389/froh.2025.1556155</pub-id><pub-id pub-id-type="pmid">40092145</pub-id></citation></ref>
<ref id="B33"><label>33.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ren</surname><given-names>Y-F</given-names></name><name><surname>Feng</surname><given-names>L</given-names></name><name><surname>Serban</surname><given-names>D</given-names></name><name><surname>Malmstrom</surname><given-names>HS</given-names></name></person-group>. <article-title>Effects of common beverage colorants on color stability of dental composite resins: the utility of a thermocycling stain challenge model in vitro</article-title>. <source>J Dent</source><italic>.</italic> (<year>2012</year>) <volume>40</volume>:<fpage>e48</fpage>&#x2013;<lpage>56</lpage>. <pub-id pub-id-type="doi">10.1016/j.jdent.2012.04.017</pub-id><pub-id pub-id-type="pmid">22542498</pub-id></citation></ref>
<ref id="B34"><label>34.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gonulol</surname><given-names>N</given-names></name><name><surname>Ozer</surname><given-names>S</given-names></name><name><surname>Sen Tunc</surname><given-names>E</given-names></name></person-group>. <article-title>Water sorption, solubility, and color stability of giomer restoratives</article-title>. <source>J Esthet Restor Dent</source>. (<year>2015</year>) <volume>27</volume>(<issue>5</issue>):<fpage>300</fpage>&#x2013;<lpage>6</lpage>. <pub-id pub-id-type="doi">10.1111/jerd.12119</pub-id><pub-id pub-id-type="pmid">25145876</pub-id></citation></ref>
<ref id="B35"><label>35.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Daneshpooy</surname><given-names>M</given-names></name><name><surname>Kimyai</surname><given-names>S</given-names></name><name><surname>Sani</surname><given-names>RA</given-names></name></person-group>. <article-title>Effect of repeated preheating on color stability of three types of composite resins and a giomer: an in vitro study</article-title>. <source>J Dent Res Dent Clin Dent Prospects</source>. (<year>2024</year>) <volume>18</volume>(<issue>2</issue>):<fpage>110</fpage>. <pub-id pub-id-type="doi">10.34172/joddd.41167</pub-id><pub-id pub-id-type="pmid">39071214</pub-id></citation></ref>
<ref id="B36"><label>36.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sousa</surname><given-names>SEP</given-names></name><name><surname>da Costa</surname><given-names>ES</given-names></name><name><surname>Borges</surname><given-names>BCD</given-names></name><name><surname>de Assun&#x00E7;&#x00E3;o</surname><given-names>IV</given-names></name><name><surname>dos Santos</surname><given-names>AJS</given-names></name></person-group>. <article-title>Staining resistance of preheated flowable composites to drinking pigmented beverages</article-title>. <source>Rev Port Estomatol Med Dent Cir Maxilofac</source>. (<year>2015</year>) <volume>56</volume>(<issue>4</issue>):<fpage>221</fpage>&#x2013;<lpage>5</lpage>. <pub-id pub-id-type="doi">10.1016/j.rpemd.2015.11.009</pub-id></citation></ref>
<ref id="B37"><label>37.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Darabi</surname><given-names>F</given-names></name><name><surname>Seyed-Monir</surname><given-names>A</given-names></name><name><surname>Mihandoust</surname><given-names>S</given-names></name><name><surname>Maleki</surname><given-names>D.</given-names></name></person-group> <article-title>The effect of preheating of composite resin on its color stability after immersion in tea and coffee solutions: an in vitro study</article-title>. <source>J Clin Exp Dent</source><italic>.</italic> (<year>2019</year>) <volume>11</volume>(<issue>12</issue>):<fpage>e1151</fpage>. <pub-id pub-id-type="doi">10.4317/jced.56438</pub-id><pub-id pub-id-type="pmid">31824596</pub-id></citation></ref>
<ref id="B38"><label>38.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Amaya-Pajares</surname><given-names>SP</given-names></name><name><surname>Koi</surname><given-names>K</given-names></name><name><surname>Watanabe</surname><given-names>H</given-names></name><name><surname>da Costa</surname><given-names>JB</given-names></name><name><surname>Ferracane</surname><given-names>JL</given-names></name></person-group>. <article-title>Development and maintenance of surface gloss of dental composites after polishing and brushing: review of the literature</article-title>. <source>J Esthet Restor Dent</source><italic>.</italic> (<year>2022</year>) <volume>34</volume>(<issue>1</issue>):<fpage>15</fpage>&#x2013;<lpage>41</lpage>. <pub-id pub-id-type="doi">10.1111/jerd.12875</pub-id><pub-id pub-id-type="pmid">35088935</pub-id></citation></ref>
<ref id="B39"><label>39.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kilinc</surname><given-names>H</given-names></name><name><surname>Turgut</surname><given-names>S</given-names></name></person-group>. <article-title>Optical behaviors of esthetic CAD-CAM restorations after different surface finishing and polishing procedures and UV aging: an in vitro study</article-title>. <source>J Prosthet Dent</source><italic>.</italic> (<year>2018</year>) <volume>120</volume>(<issue>1</issue>):<fpage>107</fpage>&#x2013;<lpage>13</lpage>. <pub-id pub-id-type="doi">10.1016/j.prosdent.2017.09.019</pub-id><pub-id pub-id-type="pmid">29310878</pub-id></citation></ref>
<ref id="B40"><label>40.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>da Costa</surname><given-names>JB</given-names></name><name><surname>Ferracane</surname><given-names>JL</given-names></name><name><surname>Amaya-Pajares</surname><given-names>S</given-names></name><name><surname>Pfefferkorn</surname><given-names>F</given-names></name></person-group>. <article-title>Visually acceptable gloss threshold for resin composite and polishing systems</article-title>. <source>J Am Dent Assoc</source>. (<year>2021</year>) <volume>152</volume>(<issue>5</issue>):<fpage>385</fpage>&#x2013;<lpage>92</lpage>. <pub-id pub-id-type="doi">10.1016/j.adaj.2020.09.027</pub-id><pub-id pub-id-type="pmid">33549304</pub-id></citation></ref>
<ref id="B41"><label>41.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>de Melo</surname><given-names>T</given-names></name><name><surname>Delgado</surname><given-names>A</given-names></name><name><surname>Martins</surname><given-names>R</given-names></name><name><surname>Lassila</surname><given-names>L</given-names></name><name><surname>Garoushi</surname><given-names>S</given-names></name><name><surname>Caldeira</surname><given-names>J</given-names></name><etal/></person-group> <article-title>Can specular gloss measurements predict the effectiveness of finishing/polishing protocols in dental polymers? A systematic review and linear mixed-effects prediction model</article-title>. <source>Oper Dent</source>. (<year>2022</year>) <volume>47</volume>(<issue>3</issue>):<fpage>E131</fpage>&#x2013;<lpage>51</lpage>. <pub-id pub-id-type="doi">10.2341/21-027-LIT</pub-id><pub-id pub-id-type="pmid">35776960</pub-id></citation></ref>
<ref id="B42"><label>42.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Daud</surname><given-names>A</given-names></name><name><surname>Gray</surname><given-names>G</given-names></name><name><surname>Lynch</surname><given-names>CD</given-names></name><name><surname>Wilson</surname><given-names>NH</given-names></name><name><surname>Blum</surname><given-names>IR</given-names></name></person-group>. <article-title>A randomised controlled study on the use of finishing and polishing systems on different resin composites using 3D contact optical profilometry and scanning electron microscopy</article-title>. <source>J Dent</source>. (<year>2018</year>) <volume>71</volume>:<fpage>25</fpage>&#x2013;<lpage>30</lpage>. <pub-id pub-id-type="doi">10.1016/j.jdent.2018.01.008</pub-id><pub-id pub-id-type="pmid">29360492</pub-id></citation></ref>
<ref id="B43"><label>43.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Daud</surname><given-names>A</given-names></name><name><surname>Adams</surname><given-names>AJ</given-names></name><name><surname>Shawkat</surname><given-names>A</given-names></name><name><surname>Gray</surname><given-names>G</given-names></name><name><surname>Wilson</surname><given-names>NH</given-names></name><name><surname>Lynch</surname><given-names>CD</given-names></name><etal/></person-group> <article-title>Effects of toothbrushing on surface characteristics of microhybrid and nanofilled resin composites following different finishing and polishing procedures</article-title>. <source>J Dent</source>. (<year>2020</year>) <volume>99</volume>:<fpage>103376</fpage>. <pub-id pub-id-type="doi">10.1016/j.jdent.2020.103376</pub-id><pub-id pub-id-type="pmid">32470566</pub-id></citation></ref>
<ref id="B44"><label>44.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Alhassan</surname><given-names>M</given-names></name><name><surname>Maawadh</surname><given-names>A</given-names></name><name><surname>Labban</surname><given-names>N</given-names></name><name><surname>Alnafaiy</surname><given-names>SM</given-names></name><name><surname>Alotaibi</surname><given-names>HN</given-names></name><name><surname>BinMahfooz</surname><given-names>AM</given-names></name></person-group>. <article-title>Effect of different surface treatments on the surface roughness and gloss of resin-modified CAD/CAM ceramics</article-title>. <source>Appl Sci</source><italic>.</italic> (<year>2022</year>) <volume>12</volume>(<issue>23</issue>):<fpage>11972</fpage>. <pub-id pub-id-type="doi">10.3390/app122311972</pub-id></citation></ref>
<ref id="B45"><label>45.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dionysopoulos</surname><given-names>D</given-names></name><name><surname>Tolidis</surname><given-names>K</given-names></name><name><surname>Gerasimou</surname><given-names>P</given-names></name></person-group>. <article-title>The effect of composition, temperature, and post-irradiation curing of bulk-fill resin composites on polymerization efficiency</article-title>. <source>Mater Res</source>. (<year>2016</year>) <volume>19</volume>(<issue>2</issue>):<fpage>466</fpage>&#x2013;<lpage>73</lpage>. <pub-id pub-id-type="doi">10.1590/1980-5373-MR-2015-0614</pub-id></citation></ref>
<ref id="B46"><label>46.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bucuta</surname><given-names>S</given-names></name><name><surname>Ilie</surname><given-names>N.</given-names></name></person-group> <article-title>Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin-based composites</article-title>. <source>Clin Oral Investig</source><italic>.</italic> (<year>2014</year>) <volume>18</volume>:<fpage>1991</fpage>&#x2013;<lpage>2000</lpage>. <pub-id pub-id-type="doi">10.1007/s00784-013-1177-y</pub-id><pub-id pub-id-type="pmid">24414570</pub-id></citation></ref>
<ref id="B47"><label>47.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>El-Korashy</surname><given-names>DI.</given-names></name></person-group> <article-title>Post-gel shrinkage strain and degree of conversion of preheated resin composite cured using different regimens</article-title>. <source>Oper Dent</source><italic>.</italic> (<year>2010</year>) <volume>35</volume>(<issue>2</issue>):<fpage>172</fpage>&#x2013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.2341/09-072-L</pub-id><pub-id pub-id-type="pmid">20420060</pub-id></citation></ref>
<ref id="B48"><label>48.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zovko</surname><given-names>R</given-names></name><name><surname>Cvitanovi&#x0107;</surname><given-names>S</given-names></name><name><surname>Mabi&#x0107;</surname><given-names>M</given-names></name><name><surname>&#x0160;arac</surname><given-names>Z</given-names></name><name><surname>&#x0106;ori&#x0107;</surname><given-names>A</given-names></name><name><surname>Glavina</surname><given-names>D</given-names></name><etal/></person-group> <article-title>The effect of chemical degradation and polishing on the gloss of composite dental materials</article-title>. <source>Materials (Basel)</source><italic>.</italic> (<year>2023</year>) <volume>16</volume>(<issue>10</issue>):<fpage>3727</fpage>. <pub-id pub-id-type="doi">10.3390/ma16103727</pub-id><pub-id pub-id-type="pmid">37241353</pub-id></citation></ref>
<ref id="B49"><label>49.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yap</surname><given-names>AU</given-names></name><name><surname>Yap</surname><given-names>S</given-names></name><name><surname>Teo</surname><given-names>C</given-names></name><name><surname>Ng</surname><given-names>J</given-names></name></person-group>. <article-title>Comparison of surface finish of new aesthetic restorative materials</article-title>. <source>Oper Dent</source>. (<year>2004</year>) <volume>29</volume>(<issue>1</issue>):<fpage>100</fpage>&#x2013;<lpage>4</lpage>.<pub-id pub-id-type="pmid">14753340</pub-id></citation></ref>
<ref id="B50"><label>50.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lempel</surname><given-names>E</given-names></name><name><surname>&#x0150;ri</surname><given-names>Z</given-names></name><name><surname>Szalma</surname><given-names>J</given-names></name><name><surname>Lov&#x00E1;sz</surname><given-names>BV</given-names></name><name><surname>Kiss</surname><given-names>A</given-names></name><name><surname>T&#x00F3;th</surname><given-names>&#x00C1;</given-names></name><etal/></person-group> <article-title>Effect of exposure time and pre-heating on the conversion degree of conventional, bulk-fill, fiber-reinforced, and polyacid-modified resin composites</article-title>. <source>Dent Mater</source><italic>.</italic> (<year>2019</year>) <volume>35</volume>(<issue>2</issue>):<fpage>217</fpage>&#x2013;<lpage>28</lpage>. <pub-id pub-id-type="doi">10.1016/j.dental.2018.11.017</pub-id><pub-id pub-id-type="pmid">30503020</pub-id></citation></ref>
<ref id="B51"><label>51.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Elkaffass</surname><given-names>A-A</given-names></name><name><surname>Eltoukhy</surname><given-names>R-I</given-names></name><name><surname>Mahmoud</surname><given-names>S-H</given-names></name></person-group>. <article-title>Influence of preheating on mechanical and surface properties of nanofilled resin composites</article-title>. <source>J Clin Exp Dent</source><italic>.</italic> (<year>2020</year>) <volume>12</volume>(<issue>5</issue>):<fpage>e494</fpage>. <pub-id pub-id-type="doi">10.4317/jced.56469</pub-id><pub-id pub-id-type="pmid">32509233</pub-id></citation></ref>
<ref id="B52"><label>52.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Degirmenci</surname><given-names>A</given-names></name><name><surname>Can</surname><given-names>DB</given-names></name></person-group>. <article-title>Pre-heating effect on the microhardness and depth of cure of bulk-fill composite resins</article-title>. <source>Odovtos Int J Dent Sci</source><italic>.</italic> (<year>2022</year>) <volume>24</volume>(<issue>1</issue>):<fpage>99</fpage>&#x2013;<lpage>112</lpage>. <pub-id pub-id-type="doi">10.15517/ijds.2021.47209</pub-id></citation></ref>
<ref id="B53"><label>53.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bilge</surname><given-names>K</given-names></name><name><surname>Eskiba&#x011F;lar</surname><given-names>BK</given-names></name><name><surname>Ipek</surname><given-names>I</given-names></name></person-group>. <article-title>Pre-heating effect on microhardness of different restorative materials</article-title>. <source>Int Dent J</source>. (<year>2024</year>) <volume>74</volume>:<fpage>S35</fpage>. <pub-id pub-id-type="doi">10.1016/j.identj.2024.07.675</pub-id></citation></ref>
<ref id="B54"><label>54.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Elkaffas</surname><given-names>AA</given-names></name><name><surname>Eltoukhy</surname><given-names>RI</given-names></name><name><surname>Elnegoly</surname><given-names>SA</given-names></name><name><surname>Mahmoud</surname><given-names>SH</given-names></name></person-group>. <article-title>The effect of preheating resin composites on surface hardness: a systematic review and meta-analysis</article-title>. <source>Restor Dent Endod</source>. (<year>2019</year>) <volume>44</volume>(<issue>4</issue>). <pub-id pub-id-type="doi">10.5395/rde.2019.44.e41</pub-id><pub-id pub-id-type="pmid">31799169</pub-id></citation></ref>
<ref id="B55"><label>55.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Trujillo</surname><given-names>M</given-names></name><name><surname>Newman</surname><given-names>SM</given-names></name><name><surname>Stansbury</surname><given-names>JW</given-names></name></person-group>. <article-title>Use of near-IR to monitor the influence of external heating on dental composite photopolymerization</article-title>. <source>Dent Mater</source><italic>.</italic> (<year>2004</year>) <volume>20</volume>(<issue>8</issue>):<fpage>766</fpage>&#x2013;<lpage>77</lpage>. <pub-id pub-id-type="doi">10.1016/j.dental.2004.02.003</pub-id><pub-id pub-id-type="pmid">15302457</pub-id></citation></ref>
<ref id="B56"><label>56.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Daronch</surname><given-names>M</given-names></name><name><surname>Rueggeberg</surname><given-names>FA</given-names></name><name><surname>De Goes</surname><given-names>M</given-names></name><name><surname>Giudici</surname><given-names>R</given-names></name></person-group>. <article-title>Polymerization kinetics of pre-heated composite</article-title>. <source>J Dent Res</source><italic>.</italic> (<year>2006</year>) <volume>85</volume>(<issue>1</issue>):<fpage>38</fpage>&#x2013;<lpage>43</lpage>. <pub-id pub-id-type="doi">10.1177/154405910608500106</pub-id><pub-id pub-id-type="pmid">16373678</pub-id></citation></ref>
<ref id="B57"><label>57.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Poggio</surname><given-names>C</given-names></name><name><surname>Viola</surname><given-names>M</given-names></name><name><surname>Mirando</surname><given-names>M</given-names></name><name><surname>Chiesa</surname><given-names>M</given-names></name><name><surname>Beltrami</surname><given-names>R</given-names></name><name><surname>Colombo</surname><given-names>M.</given-names></name></person-group> <article-title>Microhardness of different esthetic restorative materials: evaluation and comparison after exposure to acidic drink</article-title>. <source>Dent Res J</source>. (<year>2018</year>) <volume>15</volume>(<issue>3</issue>):<fpage>166</fpage>. <pub-id pub-id-type="doi">10.4103/1735-3327.231863</pub-id></citation></ref></ref-list>
</back>
</article>