<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3-mathml3.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:ali="http://www.niso.org/schemas/ali/1.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" article-type="review-article" dtd-version="1.3" xml:lang="EN">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Oncol.</journal-id>
<journal-title-group>
<journal-title>Frontiers in Oncology</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Oncol.</abbrev-journal-title>
</journal-title-group>
<issn pub-type="epub">2234-943X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fonc.2026.1748836</article-id>
<article-version article-version-type="Version of Record" vocab="NISO-RP-8-2008"/>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Review</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Multimodal imaging techniques in Yttrium-90 radioembolization for hepatocellular carcinoma: a modality-oriented clinical review</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name><surname>Yang</surname><given-names>Tingting</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/2938901/overview"/>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="conceptualization" vocab-term-identifier="https://credit.niso.org/contributor-roles/conceptualization/">Conceptualization</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Data curation" vocab-term-identifier="https://credit.niso.org/contributor-roles/data-curation/">Data curation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Formal analysis" vocab-term-identifier="https://credit.niso.org/contributor-roles/formal-analysis/">Formal analysis</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="investigation" vocab-term-identifier="https://credit.niso.org/contributor-roles/investigation/">Investigation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="methodology" vocab-term-identifier="https://credit.niso.org/contributor-roles/methodology/">Methodology</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="validation" vocab-term-identifier="https://credit.niso.org/contributor-roles/validation/">Validation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; original draft" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-original-draft/">Writing &#x2013; original draft</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &amp; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-review-editing/">Writing &#x2013; review &amp; editing</role>
</contrib>
<contrib contrib-type="author">
<name><surname>Zhang</surname><given-names>Lijie</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/1240800/overview"/>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Formal analysis" vocab-term-identifier="https://credit.niso.org/contributor-roles/formal-analysis/">Formal analysis</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="validation" vocab-term-identifier="https://credit.niso.org/contributor-roles/validation/">Validation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; original draft" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-original-draft/">Writing &#x2013; original draft</role>
</contrib>
<contrib contrib-type="author">
<name><surname>Xu</surname><given-names>Wei</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Data curation" vocab-term-identifier="https://credit.niso.org/contributor-roles/data-curation/">Data curation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="validation" vocab-term-identifier="https://credit.niso.org/contributor-roles/validation/">Validation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; original draft" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-original-draft/">Writing &#x2013; original draft</role>
</contrib>
<contrib contrib-type="author">
<name><surname>Zheng</surname><given-names>Chuansheng</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/864097/overview"/>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="conceptualization" vocab-term-identifier="https://credit.niso.org/contributor-roles/conceptualization/">Conceptualization</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Formal analysis" vocab-term-identifier="https://credit.niso.org/contributor-roles/formal-analysis/">Formal analysis</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="validation" vocab-term-identifier="https://credit.niso.org/contributor-roles/validation/">Validation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &amp; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-review-editing/">Writing &#x2013; review &amp; editing</role>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name><surname>Liang</surname><given-names>Bin</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<xref ref-type="corresp" rid="c001"><sup>*</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/1029662/overview"/>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="conceptualization" vocab-term-identifier="https://credit.niso.org/contributor-roles/conceptualization/">Conceptualization</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Formal analysis" vocab-term-identifier="https://credit.niso.org/contributor-roles/formal-analysis/">Formal analysis</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="validation" vocab-term-identifier="https://credit.niso.org/contributor-roles/validation/">Validation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &amp; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-review-editing/">Writing &#x2013; review &amp; editing</role>
</contrib>
</contrib-group>
<aff id="aff1"><label>1</label><institution>Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology</institution>, <city>Wuhan</city>,&#xa0;<country country="cn">China</country></aff>
<aff id="aff2"><label>2</label><institution>Hubei Provincial Clinical Research Center for Precision Radiology &amp; Interventional Medicine</institution>, <city>Wuhan</city>,&#xa0;<country country="cn">China</country></aff>
<aff id="aff3"><label>3</label><institution>Hubei Province Key Laboratory of Molecular Imaging</institution>, <city>Wuhan</city>,&#xa0;<country country="cn">China</country></aff>
<author-notes>
<corresp id="c001"><label>*</label>Correspondence: Bin Liang, <email xlink:href="mailto:bliang@hust.edu.cn">bliang@hust.edu.cn</email></corresp>
</author-notes>
<pub-date publication-format="electronic" date-type="pub" iso-8601-date="2026-02-03">
<day>03</day>
<month>02</month>
<year>2026</year>
</pub-date>
<pub-date publication-format="electronic" date-type="collection">
<year>2026</year>
</pub-date>
<volume>16</volume>
<elocation-id>1748836</elocation-id>
<history>
<date date-type="received">
<day>18</day>
<month>11</month>
<year>2025</year>
</date>
<date date-type="accepted">
<day>07</day>
<month>01</month>
<year>2026</year>
</date>
<date date-type="rev-recd">
<day>01</day>
<month>01</month>
<year>2026</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2026 Yang, Zhang, Xu, Zheng and Liang.</copyright-statement>
<copyright-year>2026</copyright-year>
<copyright-holder>Yang, Zhang, Xu, Zheng and Liang</copyright-holder>
<license>
<ali:license_ref start_date="2026-02-03">https://creativecommons.org/licenses/by/4.0/</ali:license_ref>
<license-p>This is an open-access article distributed under the terms of the <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">Creative Commons Attribution License (CC BY)</ext-link>. The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</license-p>
</license>
</permissions>
<abstract>
<p>Hepatocellular carcinoma  (HCC) is one of the most common malignancies with high global mortality. Yttrium-90 selective internal radiation therapy (<sup>90</sup>Y-SIRT) is a precision radio-interventional treatment whose efficacy and safety critically depend on accurate microsphere delivery and dose distribution. This review provides an overview of imaging techniques used in <sup>90</sup>Y-SIRT, emphasizing both single-modality and multimodal approaches. We summarize the clinical value of ultrasound, CT, MRI, angiography, and nuclear medicine, each providing anatomical, functional, or metabolic information. We further discuss multimodal imaging integration across the treatment workflow: pre-procedural fusion supports patient selection and dose planning; intraprocedural volumetric imaging guides catheter placement; and post-treatment functional imaging assesses microsphere distribution and therapeutic response. By consolidating current evidence, this review highlights the clinical utility of multimodal imaging and identifies areas for optimization in treatment planning, procedural guidance, and outcome assessment of <sup>90</sup>Y-SIRT. This synthesis serves as a practical reference for clinicians and researchers aiming to improve the precision and effectiveness of radioembolization for HCC.</p>
</abstract>
<kwd-group>
<kwd>90Y</kwd>
<kwd>clinical application</kwd>
<kwd>hepatocellular carcinoma</kwd>
<kwd>multimodal imaging</kwd>
<kwd>radioembolization</kwd>
</kwd-group>
<funding-group>
<funding-statement>The author(s) declared that financial support was not received for this work and/or its publication.</funding-statement>
</funding-group>
<counts>
<fig-count count="5"/>
<table-count count="0"/>
<equation-count count="0"/>
<ref-count count="78"/>
<page-count count="13"/>
<word-count count="6848"/>
</counts>
<custom-meta-group>
<custom-meta>
<meta-name>section-at-acceptance</meta-name>
<meta-value>Cancer Imaging and Image-directed Interventions</meta-value>
</custom-meta>
</custom-meta-group>
</article-meta>
</front>
<body>
<sec id="s1" sec-type="intro">
<label>1</label>
<title>Introduction</title>
<p>Hepatocellular carcinoma (HCC) is the sixth most common malignancy and the third leading cause of cancer-related deaths worldwide (<xref ref-type="bibr" rid="B1">1</xref>). Due to its insidious clinical presentation, a substantial proportion of patients are diagnosed at intermediate or advanced stages, and less than 30% are candidates for curative treatments at initial diagnosis (<xref ref-type="bibr" rid="B2">2</xref>, <xref ref-type="bibr" rid="B3">3</xref>). Consequently, locoregional therapies play a pivotal role in the multidisciplinary management of HCC (<xref ref-type="bibr" rid="B4">4</xref>). Yttrium-90 selective internal radiation therapy (<sup>90</sup>Y-SIRT) has emerged as an important locoregional treatment option that can be applied across various stages of HCC (<xref ref-type="bibr" rid="B5">5</xref>, <xref ref-type="bibr" rid="B6">6</xref>). By selectively delivering radioactive microspheres into tumor-feeding arteries, &#x2060;<sup>90</sup>Y-SIRT achieves high-dose internal irradiation of tumor tissue through the emission of high-energy &#x3b2;-particles, while relatively sparing non-tumorous liver parenchyma (<xref ref-type="bibr" rid="B7">7</xref>). Nevertheless, given the high radioactivity of <sup>90</sup>Y microspheres, treatment efficacy and safety are critically dependent on precise microsphere delivery (<xref ref-type="bibr" rid="B8">8</xref>). Inaccurate administration or ectopic embolization may lead to severe complications or even death (<xref ref-type="bibr" rid="B8">8</xref>, <xref ref-type="bibr" rid="B9">9</xref>). As a result, the successful implementation of &#x2060;<sup>90</sup>Y-SIRT requires meticulous patient selection, accurate pre-procedural assessment of vascular anatomy, microsphere distribution, and dosimetry, as well as reliable intra-procedural guidance and post-treatment monitoring (<xref ref-type="bibr" rid="B5">5</xref>). In clinical practice, however, individual imaging modalities each provide complementary but incomplete information regarding tumor anatomy, vascular complexity, extrahepatic shunting, and microsphere distribution (<xref ref-type="bibr" rid="B10">10</xref>). Conventional anatomical imaging, angiographic techniques, and nuclear medicine imaging each provide distinct but inherently limited information, particularly with regard to accurately depicting microsphere distribution and predicting radiation dose delivery (<xref ref-type="bibr" rid="B10">10</xref>). Multimodal imaging, defined as the integration of two or more imaging modalities into a single framework, enables the fusion of anatomical, functional, and molecular information, providing more accurate diagnostic and therapeutic guidance than any single imaging technique (<xref ref-type="bibr" rid="B11">11</xref>). In the context of <sup>90</sup>Y-SIRT, multimodal imaging supports the entire treatment continuum.</p>
<p>This review aims to provide a modality-oriented overview of imaging techniques used in &#x2060;<sup>90</sup>Y-SIRT for HCC, summarizing the clinical value of single-modality imaging and the role of multimodal imaging in procedural guidance and treatment optimization. By systematically integrating information across different imaging modalities, this review highlights their complementary strengths and provides a comprehensive perspective on how multimodal imaging can improve treatment planning, dose delivery, and outcome prediction. As shown in <xref ref-type="fig" rid="f1"><bold>Figure&#xa0;1</bold></xref>, we outline recent advances and challenges in the application of multimodal imaging throughout the <sup>90</sup>Y-SIRT workflow, highlighting its pivotal role in treatment planning, efficacy optimization, and the prospects for future development.</p>
<fig id="f1" position="float">
<label>Figure&#xa0;1</label>
<caption>
<p>Multimodal imaging techniques across the yttrium-90 selective internal radiation therapy (<sup>90</sup>Y-SIRT) workflow for hepatocellular carcinoma. This schematic summarizes the roles of different imaging modalities at each stage of <sup>90</sup>Y-SIRT, from pre-procedural planning through intra-procedural navigation to post-treatment assessment. Solid circles denote core imaging guiding therapy; circles with surrounding squares indicate complementary or optional imaging. Abbreviations: <sup>90</sup>Y-SIRT, yttrium-90 selective internal radiotherapy; US, ultrasound; CEUS, contrast-enhanced ultrasound; CBCT, cone-beam CT; Angio-CT, angiography CT; PET/CT, positron emission tomography/CT, SPECT/CT, single-photon emission computed tomography/CT.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fonc-16-1748836-g001.tif">
<alt-text content-type="machine-generated">Multimodal imaging techniques across the 90Y-SIRT workflow are detailed in three stages: pre-procedural planning, intra-procedural navigation, and post-treatment assessment. Each stage features corresponding imaging modalities and objectives. Pre-procedural planning includes patient selection and tumor evaluation. Intra-procedural navigation focuses on catheter positioning and microsphere delivery optimization. Post-treatment assessment involves dosimetry evaluation and long-term follow-up. Illustrations show liver images at each stage, depicting arterial anatomy, catheter placement, and necrosis evaluation. Imaging techniques like US/CEUS, CT, MRI, and PET/CT are categorized by primary and adjunctive modalities.</alt-text>
</graphic></fig>
</sec>
<sec id="s2">
<label>2</label>
<title>Cross-sectional anatomical imaging in <sup>90</sup>Y-SIRT</title>
<sec id="s2_1">
<label>2.1</label>
<title>US based imaging</title>
<p>Ultrasound (US) serves as the primary surveillance modality for patients at risk of HCC, acting as the initial screening tool before patients are considered for <sup>90</sup>Y-SIRT. While B-mode US is non-invasive, its utility for treatment planning is restricted by variable image quality. Schoenberger et&#xa0;al. reported that nearly 18% of patients with cirrhosis present with moderate-to-severe visualization limitations, with high body mass index and non-alcoholic fatty liver disease identified as independent risk factors for inadequate imaging (<xref ref-type="bibr" rid="B12">12</xref>). Consequently, clinical guidelines mandate that any nodule &#x2265; 10 mm detected on US requires further characterization with multiphasic cross-sectional imaging to confirm the diagnosis (<xref ref-type="bibr" rid="B13">13</xref>, <xref ref-type="bibr" rid="B14">14</xref>).</p>
<p>To address these limitations, contrast-enhanced ultrasound (CEUS) has been integrated into diagnostic algorithms to resolve indeterminate findings. Hawley et&#xa0;al. highlight that newer ultrasound contrast agents, such as perflubutane, possess a unique post-vascular Kupffer phase (<xref ref-type="bibr" rid="B15">15</xref>). These agents are phagocytosed by Kupffer cells in healthy parenchyma but not by malignant cells, enabling &#x201c;defect reperfusion imaging&#x201d; that facilitates whole-liver assessment and improves the detection of occult nodules missed by standard B-mode US (<xref ref-type="bibr" rid="B15">15</xref>).</p>
<p>In the specific workflow of <sup>90</sup>Y-SIRT, CEUS provides a distinct advantage for early post-treatment monitoring. Unlike bland embolization, <sup>90</sup>Y microspheres (20-30 &#x3bc;m) do not fully occlude tumor-feeding vessels, allowing residual intratumoral blood flow to be evaluated by CEUS (<xref ref-type="bibr" rid="B16">16</xref>). Delaney et&#xa0;al. demonstrated that quantitative CEUS could predict long-term response as early as 2 weeks post-treatment, significantly earlier than the standard 3&#x2013;6 months interval required for morphological changes on CT or MRI (<xref ref-type="bibr" rid="B16">16</xref>). In their study, responders exhibited a significant decrease in fractional vascularity of approximately 38% at 2 weeks, whereas non-responders showed unchanged or increased vascularity (<xref ref-type="bibr" rid="B16">16</xref>). Thus, CEUS serves as a critical adjunctive modality for monitoring early hemodynamic changes following radioembolization.</p>
</sec>
<sec id="s2_2">
<label>2.2</label>
<title>CT based techniques</title>
<p>Multidetector computed tomography (MDCT) serves as the standard modality for the initial staging and vascular mapping of hepatocellular carcinoma (HCC) prior to Yttrium-90 (<sup>90</sup>Y) radioembolization. Due to its rapid acquisition speed and high spatial resolution, multiphasic CT is indispensable for defining hepatic arterial anatomy and calculating liver volumes for dosimetry. A recent multicenter study by Yoon et&#xa0;al. reported that contrast-enhanced CT achieved a sensitivity of approximately 75% for diagnosing HCC under LI-RADS criteria, performing comparably to gadoxetic acid-enhanced MRI in scenarios where washout timing is critical (<xref ref-type="bibr" rid="B17">17</xref>). However, conventional CT remains limited in characterizing small hypovascular nodules (&lt; 2 cm) compared to MRI, and standard morphological evaluation often fails to predict microvascular invasionpreoperatively (<xref ref-type="bibr" rid="B18">18</xref>).</p>
<p>To enhance diagnostic capabilities, dual-energy CT (DECT) has been introduced to differentiate materials based on their energy-related attenuation characteristics. Silva et&#xa0;al. highlight that DECT can generate material density images, such as iodine and water maps (<xref ref-type="bibr" rid="B19">19</xref>). These maps allow for the reconstruction of virtual unenhanced images, potentially eliminating the need for a true non-contrast phase and reducing radiation dose (<xref ref-type="bibr" rid="B19">19</xref>). Furthermore, monochromatic images generated by DECT improve the contrast-to-noise ratio, aiding in the distinction of true contrast enhancement from hemorrhage or calcification, which is particularly valuable in complex post-treatment scenarios (<xref ref-type="bibr" rid="B19">19</xref>).</p>
<p>In the specific context of post-<sup>90</sup>Y-SIRT assessment, DECT addresses the limitations of size-based criteria, as radioembolization is cytostatic and tumors often do not shrink immediately despite necrosis. Altenbernd et&#xa0;al. demonstrated that quantifying iodine uptake via DECT is a superior biomarker for response compared to morphological criteria (<xref ref-type="bibr" rid="B20">20</xref>). In their prospective study, iodine uptake classification identified 26 partial responders, whereas standard American Association for the Study of Liver Diseases criteria identified only 8 responders within the same cohort (<xref ref-type="bibr" rid="B20">20</xref>). By visualizing the loss of vascularity rather than mere shrinkage, DECT provides a more accurate indication of therapeutic success (<xref ref-type="bibr" rid="B20">20</xref>).</p>
<p>Beyond spectral imaging, CT radiomics and CT liver perfusion (CTLP) offer functional insights into tumor microcirculation. Zhong et&#xa0;al. developed a radiomics model that achieved high accuracy (AUC 0.890) in preoperatively predicting microvascular invasion and relapse-free survival in HCC &#x2265; 3 cm (<xref ref-type="bibr" rid="B21">21</xref>). Regarding perfusion parameters, Hayano et&#xa0;al. showed that HCCs exhibit significantly higher blood volume than hypovascular metastases but lower values than hypervascular metastases (<xref ref-type="bibr" rid="B22">22</xref>). Additionally, Kalarakis et&#xa0;al. found that optimizing CTLP protocols could reduce radiation exposure by nearly 50% without compromising diagnostic accuracy (<xref ref-type="bibr" rid="B23">23</xref>). In post-treatment monitoring, Reiner et&#xa0;al. found that a significant decrease in arterial perfusion on CTLP 4 weeks after radioembolization correlated with improved 1-year survival in patients with liver metastases (<xref ref-type="bibr" rid="B24">24</xref>).</p>
</sec>
<sec id="s2_3">
<label>2.3</label>
<title>MRI based techniques</title>
<p>MRI serves as the reference standard for the diagnosis, treatment planning, and response assessment of HCC in the context of <sup>90</sup>Y-SIRT, owing to its superior soft-tissue contrast and multiparametric functional capabilities. The application of hepatobiliary-specific contrast agents, such as gadoxetic acid (Gd-EOB-DTPA), significantly refines diagnostic accuracy by exploiting organic anion transporting polypeptides (OATP). Since HCC cells typically lack functional OATP1B3 expression, most HCC lesions appear hypointense during the hepatobiliary phase, thereby improving lesion conspicuity and facilitating the detection of iso- or hypovascular tumors (<xref ref-type="bibr" rid="B25">25</xref>). A head-to-head meta-analysis confirms this superiority, demonstrating a pooled sensitivity of 86% for Gd-EOB-DTPA-enhanced MRI compared to 70% for MDCT (<xref ref-type="bibr" rid="B26">26</xref>). This advantage is critical for small lesions; for tumors &#x2264; 1 cm, MRI sensitivity (46%) is more than double that of CT (20%) (<xref ref-type="bibr" rid="B26">26</xref>). Diagnostic performance of MRI remains guideline-dependent; applying Asian Pacific Association for the Study of the Liver criteria yields a sensitivity of 89.3%, whereas LI-RADS criteria reduce sensitivity to 70.6% but ensure a specificity of 90.4%, minimizing false-positive allocations for radioembolization (<xref ref-type="bibr" rid="B17">17</xref>).</p>
<p>Diffusion-weighted imaging (DWI) provides functional information by probing the random Brownian motion of water molecules, which is inversely correlated with tissue cellularity and cell membrane integrity. Malignant tumors typically exhibit restricted diffusion due to high cellular density, resulting in high signal intensity on high b-value images and low values on the quantitative apparent diffusion coefficient (ADC) map (<xref ref-type="bibr" rid="B25">25</xref>, <xref ref-type="bibr" rid="B27">27</xref>). As an advanced application of diffusion sequences, intravoxel incoherent motion (IVIM) imaging utilizes multiple b-values to distinguish true molecular diffusion from perfusion-related pseudo-diffusion (<xref ref-type="bibr" rid="B28">28</xref>, <xref ref-type="bibr" rid="B29">29</xref>). This allows for the simultaneous assessment of tissue cellularity and capillary microcirculation without the need for intravenous contrast, providing a unique non-invasive perspective on the tumor microenvironment prior to and following embolization (<xref ref-type="bibr" rid="B27">27</xref>).</p>
<p>Dynamic contrast-enhanced MRI (DCE-MRI) is the gold standard for the quantitative assessment of tumor vascularity, analyzing the pharmacokinetics of contrast agent distribution to derive parameters such as the volume transfer constant and arterial flow (<xref ref-type="bibr" rid="B29">29</xref>). Given that <sup>90</sup>Y-SIRT relies on the exclusive arterial supply of HCCs, DCE-MRI provides direct mechanistic insights into therapeutic efficacy. Technological advancements like golden-angle radial sparse parallel (GRASP) acquisition have overcome traditional temporal resolution limitations (<xref ref-type="bibr" rid="B30">30</xref>). GRASP enables free-breathing perfusion imaging that yields quantitative parameters, such as arterial liver perfusion and hepatic perfusion index, which demonstrate excellent agreement with volume perfusion CT (ICC &#x2265; 0.88) but without the associated ionizing radiation (<xref ref-type="bibr" rid="B30">30</xref>).</p>
<p>For <sup>90</sup>Y-SIRT procedural planning, precise target definition is a prerequisite for accurate dosimetry. Conventional anatomical sequences may suffer from inter-observer variability. The application of multisource adaptive MRI fusion, which computationally synthesizes T1-weighted, T2-weighted, and DWI data, elevates the tumor contrast-to-noise ratio to 9.82, vastly superior to the 0.72 of planning CT (<xref ref-type="bibr" rid="B31">31</xref>). This fusion technique improves the consistency of gross tumor volume delineation, achieving a Dice similarity coefficient of 0.95 (<xref ref-type="bibr" rid="B31">31</xref>, <xref ref-type="bibr" rid="B32">32</xref>). Additionally, baseline texture analysis (radiomics) of DCE-MRI maps offers prognostic value; high intratumoral heterogeneity in arterial fraction has been identified as a robust predictor of long-term complete response to radioembolization (AUC = 0.857) [7].</p>
<p>Post-procedural response assessment with MRI addresses the inherent limitations of anatomical criteria. Following <sup>90</sup>Y-SIRT, tumors often undergo coagulation necrosis without immediate shrinkage; studies indicate no significant change in tumor size at 30 days post-treatment (mean 9.4 cm to 9.2 cm), rendering standard RECIST criteria insensitive in the early phase [9]. Conversely, functional metrics respond rapidly. A reduction in arterial enhancement by approximately 22% is an early sign of devascularization [9]. Similarly, IVIM imaging can detect significant decreases in arterial flow and pseudodiffusion coefficients as early as 6 weeks post-treatment (<xref ref-type="bibr" rid="B28">28</xref>). Critically, quantitative ADC changes have prognostic value: an increase in ADC greater than 30% at 30 days post-treatment is a potent predictor of objective response (sensitivity 90%) and correlates with significantly prolonged median overall survival (13.9 months vs. 5.5 months in non-responders) (<xref ref-type="bibr" rid="B33">33</xref>). However, hemorrhagic necrosis can cause high T1 signal intensity on pre-contrast images, obscuring viable tumor enhancement. Image subtraction techniques effectively mitigate this confounder, improving the sensitivity for detecting complete tumor necrosis to 78.1%, compared to only 28.1% with non-subtracted images (<xref ref-type="bibr" rid="B34">34</xref>).</p>
</sec>
</sec>
<sec id="s3">
<label>3</label>
<title>Angiographic imaging techniques in <sup>90</sup>Y-SIRT</title>
<p>Angiographic imaging constitutes the procedural backbone of <sup>90</sup>Y-SIRT, essential not only for intra-procedural guidance but also for pre-treatment vascular mapping and flow dynamic assessment. Once a patient is deemed eligible, a comprehensive angiographic evaluation is performed to document hepatic arterial anatomy and identify tumor-feeding vessels. This step is critical for detecting hazardous extrahepatic branches or anastomoses that could lead to non-target microsphere deposition, thereby allowing for catheter repositioning or prophylactic embolization when necessary (<xref ref-type="bibr" rid="B35">35</xref>).</p>
<sec id="s3_1">
<label>3.1</label>
<title>Digital subtraction angiography</title>
<p>DSA remains the reference standard for pre-procedural vascular mapping. A thorough understanding of hepatic arterial variants is a prerequisite for successful radioembolization, as the standard anatomy (Michels Type I) accounts for only 55%-75% of cases (<xref ref-type="bibr" rid="B36">36</xref>, <xref ref-type="bibr" rid="B37">37</xref>). Failure to recognize variants, such as replaced or accessory hepatic arteries, may compromise the accuracy of lung shunt estimation and result in incomplete tumor coverage. Furthermore, large peripherally located HCCs frequently recruit parasitic blood supply from extrahepatic sources, most commonly the right inferior phrenic artery (<xref ref-type="bibr" rid="B38">38</xref>). Overlooking these collateral feeders precludes complete tumor treatment and necessitates comprehensive angiographic interrogation beyond the celiac axis (<xref ref-type="bibr" rid="B38">38</xref>).</p>
<p>In the context of <sup>90</sup>Y-SIRT, the primary utility of DSA lies in safety and hemodynamic assessment. It is essential for identifying vessels supplying the gastrointestinal tract, specifically the gastroduodenal artery, right gastric artery, and cystic artery&#x2014;to prevent complications like gastric ulceration or cholecystitis (<xref ref-type="bibr" rid="B10">10</xref>, <xref ref-type="bibr" rid="B38">38</xref>). Concurrently, DSA identifies tumor-feeding vessels and evaluates real-time hemodynamics to detect potential flow reversal caused by large hypervascular tumors; these findings collectively guide the optimal catheter positioning for the subsequent injection of Technetium-99m macroaggregated albumin (<sup>99m</sup>Tc-MAA) (<xref ref-type="bibr" rid="B38">38</xref>).</p>
<p>Despite its central role, DSA has inherent limitations. As a two-dimensional projection technique, it may obscure complex vascular overlaps and fail to detect small collateral vessels, necessitating the adjunctive use of volumetric imaging (<xref ref-type="bibr" rid="B10">10</xref>). Additionally, DSA is highly operator-dependent; its diagnostic accuracy and safety profile rely heavily on the interventionalist&#x2019;s experience in recognizing subtle vascular anomalies and achieving stable microcatheter positioning for super-selective delivery.</p>
</sec>
<sec id="s3_2">
<label>3.2</label>
<title>Cone-beam CT and angiography CT</title>
<p>Volumetric intraprocedural imaging, encompassing CBCT and Angio-CT, has evolved from an adjunctive tool to a critical component of the <sup>90</sup>Y-SIRT workflow. By providing three-dimensional soft-tissue visualization directly in the interventional suite, these modalities overcome the limitations of two-dimensional DSA in assessing vascular complexity and perfusion territories. The precise identification of tumor-feeding arteries and extrahepatic shunts is paramount for safety, yet reliance on DSA alone often results in the misclassification of vascular supply, particularly in anatomically complex regions like hepatic segments I and IV. In a study of 42 patients, Louie et&#xa0;al. found that CBCT revealed extrahepatic enhancement or incomplete tumor perfusion in 52% of cases, with 33% of these findings being exclusive to CBCT and undetectable by DSA (<xref ref-type="bibr" rid="B39">39</xref>). Heusner et&#xa0;al. further validated this diagnostic superiority, demonstrating that CBCT achieved a specificity of 96% and an accuracy of 90% for detecting extrahepatic shunts, compared to 88% and 81% for DSA, respectively (<xref ref-type="bibr" rid="B40">40</xref>). Consequently, intraprocedural volumetric imaging facilitates immediate preventative embolization of aberrant vessels, such as the falciform or right gastric arteries, significantly reducing the risk of gastrointestinal ulceration.</p>
<p>Beyond safety, volumetric imaging is essential for optimizing dosimetry by delineating the microcatheter-perfused liver volume, which often differs from anatomical lobes defined by venous landmarks on pre-procedural CT. Rhee et&#xa0;al. established that using catheter-directed CT angiography to calculate segmental volumes rather than standard lobar volumes resulted in a significantly higher calculated effective tumor dose (348 Gy vs. 100 Gy) (<xref ref-type="bibr" rid="B41">41</xref>). Gr&#xf6;zinger et&#xa0;al. reported that angiographic prediction of segmental blood supply differed from the actual perfusion territory defined by volumetric imaging in 27.3% of patients, resulting in a mean mismatch volume of 90 &#xb1; 54 mL. This discrepancy led to dose calculation differences ranging from approximately 11% to 14% for both glass and resin microspheres, depending on the treated liver lobe (<xref ref-type="bibr" rid="B42">42</xref>). Furthermore, Jafargholi Rangraz et&#xa0;al. showed that discrepancies between anatomical and perfusion-based liver lobe segmentation derived from contrast-enhanced CBCT could result in substantial absorbed dose differences, reaching up to 21 Gy for the left lobe and 9 Gy for the right lobe (<xref ref-type="bibr" rid="B43">43</xref>). These findings highlight the importance of CBCT-based perfusion territory segmentation for accurate definition of liver vascular supply in dosimetric calculations.</p>
<p>While CBCT is widely available, it is limited by a restricted field of view, susceptibility to motion artifacts, and low contrast resolution. Angio-CT systems, which integrate a fan-beam CT scanner with an angiography suite, address these limitations. Tanaka et&#xa0;al. noted that Angio-CT offers a larger field of view (up to 50 cm) and high-contrast resolution superior to CBCT, mitigating truncated-view artifacts in large patients, albeit at a higher equipment cost and radiation dose (<xref ref-type="bibr" rid="B44">44</xref>). Lionberg et&#xa0;al. emphasized that Angio-CT eliminates the need for breath-holding and provides diagnostic-quality multi-phasic imaging, enabling the detection of occult satellite lesions and more precise volumetric delineation for dosimetry (<xref ref-type="bibr" rid="B45">45</xref>). Emerging quantitative applications of Angio-CT are also being explored. Campbell et&#xa0;al. reported that the tumor enhancement ratio measured on Angio-CT showed a moderate correlation with the final <sup>90</sup>Y microsphere distribution observed on positron emission tomography (PET) (r = 0.34), which performed comparably to standard <sup>99m</sup>Tc-MAA single-photon emission computed tomography (SPECT) -based prediction (r = 0.32) (<xref ref-type="bibr" rid="B46">46</xref>). These findings suggest that angio-CT may serve as a quantitative adjunct to conventional imaging for dosimetric assessment and prediction of microsphere distribution, thereby supporting more individualized treatment planning.</p>
</sec>
</sec>
<sec id="s4">
<label>4</label>
<title>Nuclear medicine imaging for dosimetry and planning in <sup>90</sup>Y-SIRT</title>
<p>Nuclear medicine imaging represents the functional backbone of <sup>90</sup>Y-SIRT, shifting clinical focus from purely morphological assessment to metabolic and physiological characterization. This &#x201c;theranostic&#x201d; approach comprises two distinct phases: pre-treatment simulation using <sup>99m</sup>Tc-MAA to predict microsphere distribution, and post-treatment verification imaging to validate actual Yttrium-90 deposition. While SPECT has traditionally served as the workhorse for dosimetry and treatment planning, the advent of SPECT/CT hybrid imaging and PET/CT has substantially improved accuracy and enabled more personalized therapy (<xref ref-type="fig" rid="f2"><bold>Figure&#xa0;2</bold></xref>).</p>
<fig id="f2" position="float">
<label>Figure&#xa0;2</label>
<caption>
<p>Post-procedural dose verification. Images in a 56-year-old man with hepatocellular carcinoma demonstrate that the intratumoral distribution of <sup>90</sup>Y microspheres was essentially consistent with the pretreatment <sup>99m</sup>Tc-MAA prediction. <bold>(A)</bold> Axial contrast-enhanced CT image (arterial phase) shows an arterially enhancing lesion (arrow) in the right hepatic lobe, corresponding to hepatocellular carcinoma. <bold>(B)</bold> Axial Angio-CT image obtained after superselective catheterization of the posterior branch of the right hepatic artery again shows the arterially enhancing lesion (arrow). <bold>(C)</bold> Selective angiogram of the posterior branch of the right hepatic artery shows appropriate catheter position (arrow) for <sup>99m</sup>Tc-MAA delivery. <bold>(D)</bold> Coregistered <sup>99m</sup>Tc-MAA SPECT/CT and CT image shows essentially complete tumoral distribution of the <sup>99m</sup>Tc-MAA (arrow). <bold>(E)</bold> Coregistered posttherapy <sup>90</sup>Y bremsstrahlung and pretherapy CT image similarly demonstrates similar intratumoral distribution of <sup>90</sup>Y microspheres (arrow).</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fonc-16-1748836-g002.tif">
<alt-text content-type="machine-generated">A series of five abdominal CT images labeled A to E. Image A shows a liver lesion with noticeable contrast enhancement. Image B depicts a larger, enhanced liver mass. Image C presents an angiography illustrating a feeding vessel to the liver tumor. Image D combines CT and PET scans highlighting increased metabolic activity in the liver lesion. Image E displays a PET/CT fusion with vivid color indicative of high activity in the liver region. Each image has an arrow pointing to the area of interest.</alt-text>
</graphic></fig>
<sec id="s4_1">
<label>4.1</label>
<title>SPECT/CT imaging</title>
<p>SPECT/CT systems integrate functional data with detailed anatomical localization, overcoming the limitations of planar scintigraphy, such as poor spatial resolution and the lack of tissue attenuation correction. In the context of HCC, where tumor vascularity is complex and often distorted by underlying cirrhosis, this multimodal integration is critical for precise vascular mapping and quantitative dosimetry.</p>
<sec id="s4_1_1">
<label>4.1.1</label>
<title><sup>99m</sup>Tc- MAA SPECT/CT</title>
<p><sup>99m</sup>Tc-MAA scintigraphy serves as the mandatory surrogate for simulating microsphere distribution, assessing arterial perfusion, and detecting extrahepatic shunting prior to <sup>90</sup>Y-SIRT. While planar imaging was historically used, SPECT/CT has demonstrated superior diagnostic performance. Ahmadzadehfar et&#xa0;al. reported that SPECT/CT significantly improved the sensitivity for identifying extrahepatic shunting to 100%, compared to 41% for SPECT and 32% for planar imaging alone (<xref ref-type="bibr" rid="B47">47</xref>). Crucially, these findings altered the therapeutic management in 29% of patients, involving coil embolization of aberrant vessels or catheter repositioning, whereas planar imaging only impacted 7.8% of cases (<xref ref-type="bibr" rid="B47">47</xref>).</p>
<p>For the detection of gastrointestinal shunting, which poses a risk of severe ulceration, Kao et&#xa0;al. demonstrated that SPECT/CT achieved a sensitivity of 100% and an accuracy of 96%, far exceeding the 25% sensitivity of planar imaging (<xref ref-type="bibr" rid="B48">48</xref>). Lenoir et&#xa0;al. further detailed that SPECT/CT effectively identifies non-target uptake in specific anatomical sites, including the gallbladder (12.2%) and the hepatic artery (6.5%) (<xref ref-type="bibr" rid="B49">49</xref>). Notably, SPECT/CT is vital for characterizing HCC with portal vein thrombosis; tracer accumulation within the portal vein thrombosis was identified in 6.5% of scans, confirming arterial supply to the thrombus and eligibility for therapy (<xref ref-type="bibr" rid="B49">49</xref>).</p>
<p>Quantitative <sup>99m</sup>Tc-MAA SPECT/CT also plays a pivotal role in personalized dosimetry. Garin et&#xa0;al. established that a tumor-absorbed dose threshold of 205 Gy is highly predictive of treatment response. Patients receiving doses &#x2265; 205 Gy achieved a significantly prolonged median overall survival of 18 months, compared to 9 months in those receiving lower doses (<xref ref-type="bibr" rid="B50">50</xref>). Regarding safety, a lung shunt fraction exceeding 20% typically precludes treatment to prevent radiation pneumonitis (<xref ref-type="fig" rid="f3"><bold>Figure&#xa0;3</bold></xref>). However, accurate lung dosimetry allows for treatment in selected cases if the estimated lung dose remains below 30 Gy per session and 50 Gy cumulatively (<xref ref-type="bibr" rid="B51">51</xref>). Despite its utility, potential pitfalls such as coregistration errors, observed in 2.1% of cases, require careful image interpretation to avoid false-positive diagnoses (<xref ref-type="bibr" rid="B49">49</xref>).</p>
<fig id="f3" position="float">
<label>Figure&#xa0;3</label>
<caption>
<p>Importance of performing a pre-procedural <sup>99m</sup>Tc-MAA shunt scan. A 76-year-old man presented with a large hepatocellular carcinoma involving the middle hepatic vein, without extrahepatic disease. <bold>(A)</bold> Axial contrast-enhanced T1-weighted MR image (arterial phase) shows an arterially enhancing lesion (arrow) in the right hepatic lobe, corresponding to hepatocellular carcinoma. <bold>(B)</bold> Axial Angio-CT image (arterial phase) demonstrates early opacification of the main portal vein (arrow), indicating the presence of an arterioportal shunt. <bold>(C)</bold> Digital subtraction angiography performed prior to <sup>99m</sup>Tc-MAA administration shows the catheter positioned in the superior mesenteric artery. Early opacification of the main portal vein (arrow) is again seen during the arterial phase due to a high-flow shunt during contrast injection. <bold>(D)</bold><sup>99m</sup>Tc-MAA maximum intensity projection image shows radiotracer activity distributed throughout the right hepatic lobe (white arrow) and in both lungs (black arrows), reflecting extensive portal shunting. The lung shunt fraction was 40.868%, exceeding the safety threshold for <sup>90</sup>Y radioembolization, and therefore treatment was cancelled.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fonc-16-1748836-g003.tif">
<alt-text content-type="machine-generated">Panel A shows an arterial-phase contrast-enhanced MRI image with a white arrow indicating a hyperenhancing liver tumor. Panel B displays an arterial-phase Angio-CT image demonstrating early opacification of the portal vein, suggesting an arterioportal shunt. Panel C presents a digital subtraction angiography image showing catheter positioning and contrast reflux into the portal vein during arterial injection. Panel D shows a ⁹⁹ᵐTc-MAA maximum intensity projection image with radiotracer uptake throughout the right hepatic lobe and both lungs (arrows), indicating extensive hepatopulmonary shunting, with a lung shunt fraction of 40.868%.</alt-text>
</graphic></fig>
</sec>
<sec id="s4_1_2">
<label>4.1.2</label>
<title>Post-treatment <sup>90</sup>Y SPECT/CT</title>
<p>Post-treatment imaging of <sup>90</sup>Y relies on the detection of bremsstrahlung radiation produced by the interaction of &#x3b2;-particles with tissue, as <sup>90</sup>Y lacks discrete gamma emissions for conventional scintigraphy. While this modality serves as the standard for verifying microsphere deposition, it is technically challenging due to the continuous and broad energy spectrum of bremsstrahlung photons, which leads to significant scatter, septal penetration, and low spatial resolution (<xref ref-type="bibr" rid="B52">52</xref>). To mitigate these limitations, Uliel et&#xa0;al. recommend the use of medium-energy collimators and a narrowed energy window to improve image quality and prevent the overestimation of lung shunt fractions caused by scatter (<xref ref-type="bibr" rid="B52">52</xref>).</p>
<p>The primary clinical utility of post-treatment <sup>90</sup>Y SPECT/CT lies in its ability to correct false-positive findings observed on pre-treatment MAA scans, thereby confirming the safety of the procedure. Lenoir et&#xa0;al. demonstrated that while <sup>99m</sup>Tc-MAA SPECT/CT identified gallbladder uptake in 17 cases and hepatic artery uptake in 9 cases, post-treatment <sup>90</sup>Y bremsstrahlung imaging confirmed actual microsphere deposition in only 1 case for each site (<xref ref-type="bibr" rid="B49">49</xref>). This discrepancy highlights that MAA often overestimates the risk of non-target embolization due to vascular spasms or catheter positioning differences, whereas post-treatment SPECT reflects the true biodistribution (<xref ref-type="bibr" rid="B49">49</xref>).</p>
<p>Regarding dosimetry, systematic deviations exist between the predictive <sup>99m</sup>Tc-MAA model and the actual <sup>90</sup>Y distribution (<xref ref-type="bibr" rid="B53">53</xref>) (<xref ref-type="fig" rid="f4"><bold>Figure&#xa0;4</bold></xref>). Wondergem et&#xa0;al. analyzed 39 procedures and found that 68% of liver segments showed a difference greater than 10% between activity predicted by <sup>99m</sup>Tc-MAA and actual <sup>90</sup>Y activity, with catheter tip positioning identified as a significant factor influencing this disagreement (<xref ref-type="bibr" rid="B54">54</xref>). Similarly, Debebe et&#xa0;al. reported that the mean tumor-to-normal liver ratio (TNR) derived from <sup>99m</sup>Tc-MAA (9.4) was significantly higher than that measured on post-treatment <sup>90</sup>Y SPECT (5.0), suggesting that <sup>99m</sup>Tc-MAA tends to overestimate tumor uptake (<xref ref-type="bibr" rid="B55">55</xref>). This tendency was corroborated by recent studies. Cheng et&#xa0;al. found that pre-treatment <sup>99m</sup>Tc-MAA SPECT/CT yielded a higher median TNR (5.8) compared to post-treatment verification imaging (4.9), although it accurately predicted the absorbed dose to normal liver tissue (<xref ref-type="bibr" rid="B56">56</xref>). Similarly, Demir et&#xa0;al. observed that while <sup>99m</sup>Tc-MAA SPECT/CT provided reliable dose estimates for healthy liver parenchyma, it showed lower accuracy for tumor-absorbed doses, with D90 values calculated via SPECT being systematically higher than those from PET-based verification (<xref ref-type="bibr" rid="B57">57</xref>). In terms of volumetric dosimetry, achieving the minimum dose to 70% of the tumor volume (D70) of 95 Gy has been associated with objective response, whereas non-responders had a significantly lower mean D70 of 60 Gy (<xref ref-type="bibr" rid="B58">58</xref>). However, due to the inherent quantitative limitations of bremsstrahlung imaging, Elschot et&#xa0;al. noted that SPECT underestimates the dose in small lesions by up to 75%, necessitating the adoption of more advanced modalities like PET/CT for precise voxel-based dosimetry (<xref ref-type="bibr" rid="B59">59</xref>).</p>
<fig id="f4" position="float">
<label>Figure&#xa0;4</label>
<caption>
<p>An example of disagreement between tumor dose between predictive and post-treatment dosimetry. <bold>(A, B)</bold> Pre-treatment image (99mTc-MAA-SPECT/CT). <bold>(C, D)</bold> Post-treatment image (<sup>90</sup>Y-PET/MR); the tumor contoured in pink: predictive and post-treatment dose assessment were comparable (pre-treatment predicted: mean dose: 84 Gy, D50 = 83 Gy and V100 = 39%; post-treatment: mean dose: 95 Gy, D50 = 84 Gy and V100 = 44%); the tumor contoured in yellow: predictive dosimetry underestimated the tumor dose (pre-treatment predicted: mean dose: 33 Gy, D50 = 33 Gy and V100 = 0%; post-treatment measurement: mean dose: 130 Gy, D50 = 125 Gy and V100 = 67%); and the tumor contoured in red: predictive dosimetry over-estimated the tumor dose (pre-treatment predicted: mean dose: 165 Gy, D50 = 159 Gy and V100 = 86%; post-treatment: mean dose: 4 Gy, D50 = 2 Gy and V100 = 0%). <bold>(E)</bold> Dose-volume histogram of the described VOIs based on predictive and post-treatment dose assessments. In this case a different catheter positioning between MAA work-up and treatment resulted in flow variation. A preferential targeting of the tumor in the ventral part of the right liver lobe (red tumor) was observed in the work-up. On the other hand, after <sup>90</sup>Y-microsphere injection, a preferential targeting of the tumor in the dorsal part of the left liver lobe was obtained. This is one example of a potential pitfall in SIRT in general and a cause of discrepancy between <sup>99m</sup>Tc-MAA and <sup>90</sup>Y-PET in particular (53). Reproduced from Jafargholi Rangraz E et&#xa0;al., EJNMMI Physics, 2020, CC BY 4.0.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fonc-16-1748836-g004.tif">
<alt-text content-type="machine-generated">Medical imaging analysis showing four panels labeled A to D with color-coded tumor regions on grayscale scans. Panel E presents a dose-volume histogram graphing tumor treatment predictions and measurements for pink, yellow, and red regions, with absorbed dose on the x-axis and volume percentage on the y-axis.</alt-text>
</graphic></fig>
</sec>
</sec>
<sec id="s4_2">
<label>4.2</label>
<title>PET/CT imaging</title>
<sec id="s4_2_1">
<label>4.2.1</label>
<title>Tumor biology and risk stratification</title>
<p>While conventional anatomical imaging guides catheter navigation, PET/CT provides critical insights into tumor metabolic activity and biological aggressiveness, serving as a powerful tool for patient selection and risk stratification. Although <sup>18</sup>F-fluorodeoxyglucose (<sup>18</sup>F-FDG) PET has limited sensitivity (50-65%) for detecting well-differentiated HCC due to high glucose-6-phosphatase activity, Filippi et&#xa0;al. emphasize its value in identifying aggressive, poorly differentiated phenotypes that are associated with microvascular invasion and poor outcomes (<xref ref-type="bibr" rid="B60">60</xref>).</p>
<p>High FDG uptake is a robust independent predictor of survival, often outperforming traditional staging systems. In a multicenter cohort of 291 patients with BCLC stage C HCC, Na et&#xa0;al. demonstrated that patients with a low tumor-to-liver uptake ratio (TLR &lt; 3.0) had a median overall survival of 14.9 months, significantly longer than the 6.4 months observed in patients with high TLR (<xref ref-type="bibr" rid="B61">61</xref>). In the specific context of <sup>90</sup>Y-SIRT, Jreige et&#xa0;al. reported that metabolic parameters are superior to morphological criteria for predicting long-term survival. In their study, patients with low maximum standardized uptake value achieved a median overall survival of 30.9 months, compared to only 9 months for those with high metabolic activity (P = 0.02) (<xref ref-type="bibr" rid="B62">62</xref>). These findings suggest that patients with high FDG avidity represent a high-risk subgroup that may require treatment intensification or combination therapy.</p>
<p>For well-differentiated tumors that are often FDG-negative, &#xb9;&#xb9;C-acetate or <sup>18</sup>F-fluorocholine (<sup>18</sup>;F-FCH) serve as effective surrogates for cell membrane biosynthesis, offering higher sensitivity for detection (<xref ref-type="bibr" rid="B60">60</xref>). Furthermore, PET/CT is highly effective for early risk stratification post-treatment. Reizine et&#xa0;al. showed that early evaluation (4&#x2013;8 weeks post-SIRT) using <sup>18</sup>F-FDG or <sup>18</sup>F-FCH PET/CT could predict 6-month response with 100% sensitivity and 100% specificity, whereas standard mRECIST assessment at 1 month showed lower diagnostic accuracy (<xref ref-type="bibr" rid="B63">63</xref>).</p>
</sec>
<sec id="s4_2_2">
<label>4.2.2</label>
<title>Post-treatment <sup>90</sup>Y PET/CT</title>
<p>Although Yttrium-90 is a pure beta-emitter, it undergoes a minor decay branch (approximately 32 per million decays) generating internal pair production, which allows for direct imaging of microsphere biodistribution using PET scanners (<xref ref-type="bibr" rid="B64">64</xref>). This modality overcomes the fundamental resolution limitations of bremsstrahlung SPECT. Elschot et&#xa0;al. quantitatively compared the two modalities in a phantom study, demonstrating that while SPECT underestimated the absorbed dose in small spheres (10 mm) by 75%, Time-of-flight (TOF) PET reduced this underestimation to 45%, while achieving an error rate of only 11%in larger spheres (37 mm) (<xref ref-type="bibr" rid="B59">59</xref>). Furthermore, the multicenter QUEST phantom study confirmed that current-generation TOF-PET scanners can consistently reconstruct <sup>90</sup>Y activity concentrations; however, activity concentrations in small structures (&#x2264; 37 mm) are systematically underestimated, by approximately 20% for spheres larger than 20 mm, due to partial volume effects (<xref ref-type="bibr" rid="B65">65</xref>).</p>
<p>The superior spatial resolution of <sup>90</sup>Y PET/CT facilitates precise voxel-based dosimetry and the generation of dose-volume histograms (DVH), which are critical for predicting treatment efficacy. Kao et&#xa0;al. analyzed post-treatment PET dosimetry in HCC patients and identified a clear dose-response relationship: complete tumor responses were generally achieved when D70 exceeded 100 Gy, while non-responders typically had a D70 below 100 Gy (<xref ref-type="bibr" rid="B64">64</xref>). This study also established safety thresholds, noting that a mean dose of 49 Gy to the stomach was associated with gastritis, while 18 Gy was asymptomatic (<xref ref-type="bibr" rid="B64">64</xref>). A recent systematic review by Roosen et&#xa0;al. further corroborated these findings, suggesting that a target mean dose of 100&#x2013;250 Gy is generally required to induce a response in HCC, a threshold significantly higher than that for colorectal liver metastases (40&#x2013;60 Gy) (<xref ref-type="bibr" rid="B66">66</xref>). Additionally, post-treatment PET dosimetry correlates well with metabolic response; Levillain et&#xa0;al. reported a strong correlation (R&#xb2; = 0.82) between the mean absorbed dose and the reduction in total lesion glycolysis, identifying 39 Gy and 60 Gy as key metabolic response thresholds (<xref ref-type="bibr" rid="B67">67</xref>).</p>
<p>Recent technological advancements, such as long axial field-of-view (LAFOV) PET/CT systems, further enhance the utility of post-treatment imaging by offering higher sensitivity and total-body coverage. Linder et&#xa0;al. demonstrated that LAFOV systems allow for a reduced scan duration of 20 minutes while maintaining adequate image quality and quantification accuracy for dosimetry (<xref ref-type="bibr" rid="B68">68</xref>). However, challenges remain in voxel-wise dosimetry algorithms. In a 2025 comparative study, Zeimpekis et&#xa0;al. reported that despite the high sensitivity, current voxel-wise algorithms on LAFOV systems may significantly underestimate the delivered dose compared to pre-treatment SPECT planning. Specifically, the median tumor D90 measured by LAFOV PET was significantly lower than that predicted by SPECT (30.5 Gy vs 123.5 Gy), suggesting that further refinement of dosimetric tools is necessary to fully leverage this advanced technology for accurate absolute dose quantification (<xref ref-type="bibr" rid="B69">69</xref>).</p>
</sec>
</sec>
</sec>
<sec id="s5">
<label>5</label>
<title>Multimodal imaging integration across the <sup>90</sup>Y-SIRT workflow</title>
<p>The precision of <sup>90</sup>Y-SIRT relies on the accurate definition of the biological target volume during the pre-procedural phase, a task where the integration of anatomical and functional imaging significantly outperforms single-modality assessment (<xref ref-type="bibr" rid="B11">11</xref>). While CT serves as the standard for vascular mapping, it often fails to capture the full extent of viable tumor burden in cirrhotic livers. Basha et&#xa0;al. demonstrated that a combined CT and MRI protocol yields a diagnostic accuracy of 91.29%, significantly superior to the 67.6% accuracy of CT alone (<xref ref-type="bibr" rid="B70">70</xref>). This multimodal approach is particularly critical for characterizing &#x201c;borderline&#x201d; hepatic nodules; Joo et&#xa0;al. revealed that 44.0% of hepatobiliary phase hypointense nodules without arterial enhancement&#x2014;often dismissed as benign on standard CT&#x2014;are pathologically confirmed as progressed HCC (<xref ref-type="bibr" rid="B71">71</xref>). Consequently, integrating hepatobiliary phase MRI with <sup>99m</sup>Tc-MAA SPECT/CT is essential for personalized dosimetry. Although <sup>99m</sup>Tc-MAA SPECT/CT generally correlates well with final <sup>90</sup>Y biodistribution, Cheng et&#xa0;al. cautioned that it tends to overestimate the tumor-to-normal ratio in the left hepatic lobe, necessitating the cross-referencing of functional SPECT data with high-resolution anatomical MRI to prevent non-target radiation (<xref ref-type="bibr" rid="B56">56</xref>).</p>
<p>Translating these complex pre-operative plans into precise catheter delivery requires real-time intra-procedural navigation, where volumetric imaging acts as the vital link between diagnostic planning and angiographic execution. The application of &#x201c;fusion guidance&#x201d;, which overlays pre-operative cross-sectional volumes onto live fluoroscopy, transforms 2D angiography into a 3D navigational environment. Within this workflow, the joint application of functional and anatomical modalities is decisive. Rodr&#xed;guez-Fraile et&#xa0;al. highlighted that integrating intra-procedural CBCT with pre-treatment <sup>99m</sup>Tc-MAA SPECT/CT optimizes dosimetric planning; specifically, the anatomical detail from CBCT compelled a modification of the treatment plan&#x2014;such as the splitting of administered activity&#x2014;in 42% of patients with multiple feeding arteries, ensuring complete tumor coverage that would have been ambiguous on SPECT alone (<xref ref-type="bibr" rid="B72">72</xref>) (<xref ref-type="fig" rid="f5"><bold>Figure&#xa0;5</bold></xref>). Furthermore, fusing unenhanced CBCT with pre-treatment contrast-enhanced CT enhances the sensitivity for detecting small viable tumor foci to 96.5%, significantly superior to the 78.6% sensitivity of standard MDCT (<xref ref-type="bibr" rid="B73">73</xref>), thereby minimizing the risk of geographic miss during the intervention.</p>
<fig id="f5" position="float">
<label>Figure&#xa0;5</label>
<caption>
<p><bold>(a)</bold> Contrast-enhanced computed tomography (CECT) image: HCC located between segments IV and VIII. <bold>(b)</bold><sup>99m</sup>Tc-MAA SPECT/CT fusion image shows low uptake in the lateral part of the tumoral nodule. <sup>99m</sup>Tc-MAA activity was split in two doses of 50% each by IR decision, based on liver and tumoral volumes. (c, c1 and c2) C-arm cone-Beam CT (CBCT) volumetric assessment of the tumoral territory perfused by each artery. VIII segments artery (in green) fed only 32% of the tumoral volume while IV segment artery fed most of it (in orange). <bold>(d)</bold><sup>90</sup>Y PET/CT fusion image after splitting the activity according to CBCT volumes shows the adequate distribution of the microspheres throughout the lesion (80). Reproduced from Rodr&#xed;guez&#x2212;Fraile et&#xa0;al., EJNMMI Research, 2021, CC BY 4.0.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fonc-16-1748836-g005.tif">
<alt-text content-type="machine-generated">Medical imaging of the liver in various panels. Panel a shows a CT scan with a visible mass. Panel b highlights a PET scan with colored regions indicating metabolic activity. Panel c displays another scan with crosshairs centered on an abnormal area. Panel c1 shows a 3D reconstruction with green and orange segments. Panel c2 presents another 3D view emphasizing textured areas. Panel d combines PET and CT scans identifying a bright, active region.</alt-text>
</graphic></fig>
<p>Following the procedure, the focus shifts to quantitative verification, where the superior spatial resolution of PET-based modalities allows for voxel-level dosimetric validation that far exceeds the capabilities of traditional Bremsstrahlung SPECT. <sup>90</sup>Y PET/CT has established a clear dose-response relationship, with Kokabi et&#xa0;al. identifying a mean absorbed tumor dose of 253 Gy as a robust threshold for predicting objective response (AUC = 0.929) (<xref ref-type="bibr" rid="B74">74</xref>). Moving beyond average doses, the emergence of simultaneous PET/MRI offers a deeper insight into dose heterogeneity. Demir et&#xa0;al. reported that while pre-treatment SPECT accurately predicts the dose to normal liver parenchyma, it fails to capture the non-uniformity of microsphere deposition within the tumor; post-treatment <sup>90</sup>Y PET/MRI detected significantly higher &#x201c;hot spot&#x201d; doses compared to SPECT/CT (<xref ref-type="bibr" rid="B57">57</xref>). This capability to generate accurate DVH allows clinicians to distinguish between true dosimetric failure and heterogeneous coverage, as validated by Fowler et&#xa0;al. in predicting individual lesion response (<xref ref-type="bibr" rid="B75">75</xref>).</p>
<p>Finally, functional imaging provides a critical advantage in the early post-treatment window by detecting physiological responses that precede morphological tumor shrinkage. Traditional size-based criteria such as RECIST are often insensitive in the first few months due to treatment-induced edema and necrosis. In contrast, functional changes serve as immediate biomarkers of efficacy. Rhee et&#xa0;al. demonstrated that DWI can predict response as early as 1-month post-treatment, where a 10.5% increase in ADC values identified responders with 93% sensitivity (<xref ref-type="bibr" rid="B76">76</xref>). Similarly, CEUS offers an accessible bedside alternative; Delaney et&#xa0;al. showed that CEUS can detect a significant reduction in fractional vascularity (approximately 38%) in responders as early as 2 weeks after therapy (<xref ref-type="bibr" rid="B16">16</xref>). These functional metrics enable the early identification of non-responders, facilitating timely adjunctive therapies rather than waiting for delayed anatomical progression.</p>
</sec>
<sec id="s6" sec-type="conclusions">
<label>6</label>
<title>Conclusions and future perspectives</title>
<p>The evolution of Yttrium-90 radioembolization for hepatocellular carcinoma marks a paradigm shift where therapeutic efficacy increasingly depends on the depth and integration of imaging data. The transition from empirical treatment to precision oncology relies on a multimodal imaging framework transcending simple anatomical visualization. While conventional modalities like angiography and CT provide essential vascular roadmaps, they offer incomplete insights into tumor biology and metabolic activity when used in isolation. The synergistic application of functional imaging (DWI, CEUS) and molecular imaging (SPECT/CT, PET/CT) is therefore critical for constructing a comprehensive &#x201c;theranostic&#x201d; profile. This integration facilitates accurate definition of the biological target volume, reducing risks of geographic miss and non-target embolization.</p>
<p>Multimodal imaging is perhaps most valuable in mitigating inherent procedural uncertainties. Synthesizing pre-procedural functional data with intra-procedural volumetric imaging creates a validation loop, ensuring the treatment plan aligns with the actual vascular territory. The growing adoption of post-treatment quantitative validation, particularly voxel-based <sup>90</sup>Y-PET/CT dosimetry, provides a robust mechanism to correlate absorbed dose with pathological response. This shift towards quantitative dosimetry transforms imaging from a passive observation tool into an active biomarker of therapeutic success, distinguishing technical limitations from biological non-response.</p>
<p>Looking forward, the maturation of <sup>90</sup>Y-SIRT will hinge on standardizing quantitative imaging protocols across institutions to ensure reproducibility (<xref ref-type="bibr" rid="B77">77</xref>). Technical advancements, such as simultaneous PET/MRI systems, offer a promising avenue to further refine dosimetric accuracy by minimizing motion-related registration errors and improving soft-tissue contrast (<xref ref-type="bibr" rid="B75">75</xref>). Additionally, the emerging field of radiomics and artificial intelligence represents a potential supplementary tool for treatment optimization. Rather than replacing conventional interpretation, these computational analyses may help uncover subtle, non-invasive imaging phenotypes capable of predicting tumor aggressiveness or radio-resistance (<xref ref-type="bibr" rid="B78">78</xref>). The future of <sup>90</sup>Y-SIRT lies in the continued refinement of this multimodal ecosystem, where imaging data drives a personalized, predictable, and effective therapeutic strategy for patients with hepatocellular carcinoma.</p>
</sec>
</body>
<back>
<sec id="s7" sec-type="author-contributions">
<title>Author contributions</title>
<p>TY: Conceptualization, Data curation, Formal Analysis, Investigation, Methodology, Validation, Writing &#x2013; original draft, Writing &#x2013; review &amp; editing. LZ: Formal Analysis, Validation, Writing &#x2013; original draft. WX: Data curation, Validation, Writing &#x2013; original draft. CZ: Conceptualization, Formal Analysis, Validation, Writing &#x2013; review &amp; editing. BL: Conceptualization, Formal Analysis, Validation, Writing &#x2013; review &amp; editing.</p></sec>
<sec id="s9" sec-type="COI-statement">
<title>Conflict of interest</title>
<p>The author(s) declared that this work was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p></sec>
<sec id="s10" sec-type="ai-statement">
<title>Generative AI statement</title>
<p>The author(s) declared that generative AI was not used in the creation of this manuscript.</p>
<p>Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.</p></sec>
<sec id="s11" sec-type="disclaimer">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p></sec>
<ref-list>
<title>References</title>
<ref id="B1">
<label>1</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Sung</surname> <given-names>H</given-names></name>
<name><surname>Ferlay</surname> <given-names>J</given-names></name>
<name><surname>Siegel</surname> <given-names>RL</given-names></name>
<name><surname>Laversanne</surname> <given-names>M</given-names></name>
<name><surname>Soerjomataram</surname> <given-names>I</given-names></name>
<name><surname>Jemal</surname> <given-names>A</given-names></name>
<etal/>
</person-group>. 
<article-title>Global cancer statistics 2020: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries</article-title>. <source>CA Cancer J Clin</source>. (<year>2021</year>) <volume>71</volume>:<page-range>209&#x2013;49</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.3322/caac.21660</pub-id>, PMID: <pub-id pub-id-type="pmid">33538338</pub-id>
</mixed-citation>
</ref>
<ref id="B2">
<label>2</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Wang</surname> <given-names>Y</given-names></name>
<name><surname>Deng</surname> <given-names>B</given-names></name>
</person-group>. 
<article-title>Hepatocellular carcinoma: molecular mechanism, targeted therapy, and biomarkers</article-title>. <source>Cancer Met Rev</source>. (<year>2023</year>) <volume>42</volume>:<page-range>629&#x2013;52</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1007/s10555-023-10084-4</pub-id>, PMID: <pub-id pub-id-type="pmid">36729264</pub-id>
</mixed-citation>
</ref>
<ref id="B3">
<label>3</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author"><collab>Department of Medical Administration NHCotPsRoC</collab>
</person-group>. 
<article-title>Guideline for diagnosis and treatment of primary liver cancer (2024 edition)</article-title>. <source>Chin J Dig Surg</source>. (<year>2024</year>) <volume>23</volume>:<page-range>429&#x2013;78</page-range>.
</mixed-citation>
</ref>
<ref id="B4">
<label>4</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Inchingolo</surname> <given-names>R</given-names></name>
<name><surname>Posa</surname> <given-names>A</given-names></name>
<name><surname>Mariappan</surname> <given-names>M</given-names></name>
<name><surname>Spiliopoulos</surname> <given-names>S</given-names></name>
</person-group>. 
<article-title>Locoregional treatments for hepatocellular carcinoma: Current evidence and future directions</article-title>. <source>World J Gastroenterol</source>. (<year>2019</year>) <volume>25</volume>:<page-range>4614&#x2013;28</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.3748/wjg.v25.i32.4614</pub-id>, PMID: <pub-id pub-id-type="pmid">31528090</pub-id>
</mixed-citation>
</ref>
<ref id="B5">
<label>5</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Salem</surname> <given-names>R</given-names></name>
<name><surname>Mazzaferro</surname> <given-names>V</given-names></name>
<name><surname>Sangro</surname> <given-names>B</given-names></name>
</person-group>. 
<article-title>Yttrium 90 radioembolization for the treatment of hepatocellular carcinoma: biological lessons, current challenges, and clinical perspectives</article-title>. <source>Hepatology</source>. (<year>2013</year>) <volume>58</volume>:<page-range>2188&#x2013;97</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/hep.26382</pub-id>, PMID: <pub-id pub-id-type="pmid">23512791</pub-id>
</mixed-citation>
</ref>
<ref id="B6">
<label>6</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Salem</surname> <given-names>R</given-names></name>
<name><surname>Gabr</surname> <given-names>A</given-names></name>
<name><surname>Riaz</surname> <given-names>A</given-names></name>
<name><surname>Mora</surname> <given-names>R</given-names></name>
<name><surname>Ali</surname> <given-names>R</given-names></name>
<name><surname>Abecassis</surname> <given-names>M</given-names></name>
<etal/>
</person-group>. 
<article-title>Institutional decision to adopt Y90 as primary treatment for hepatocellular carcinoma informed by a 1,000-patient 15-year experience</article-title>. <source>Hepatology</source>. (<year>2018</year>) <volume>68</volume>:<page-range>1429&#x2013;40</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/hep.29691</pub-id>, PMID: <pub-id pub-id-type="pmid">29194711</pub-id>
</mixed-citation>
</ref>
<ref id="B7">
<label>7</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Jiang</surname> <given-names>Z</given-names></name>
<name><surname>Yang</surname> <given-names>F</given-names></name>
<name><surname>Wang</surname> <given-names>W</given-names></name>
</person-group>. 
<article-title>Applications of yttrium-90 (90Y) in hepatocellular carcinoma</article-title>. <source>OncoTargets Ther</source>. (<year>2024</year>) <volume>17</volume>:<page-range>149&#x2013;57</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.2147/OTT.S445898</pub-id>, PMID: <pub-id pub-id-type="pmid">38414759</pub-id>
</mixed-citation>
</ref>
<ref id="B8">
<label>8</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Riaz</surname> <given-names>A</given-names></name>
<name><surname>Awais</surname> <given-names>R</given-names></name>
<name><surname>Salem</surname> <given-names>R</given-names></name>
</person-group>. 
<article-title>Side effects of yttrium-90 radioembolization</article-title>. <source>Front Oncol</source>. (<year>2014</year>) <volume>4</volume>:<elocation-id>198</elocation-id>. doi:&#xa0;<pub-id pub-id-type="doi">10.3389/fonc.2014.00198</pub-id>, PMID: <pub-id pub-id-type="pmid">25120955</pub-id>
</mixed-citation>
</ref>
<ref id="B9">
<label>9</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Control</surname> <given-names>BNMQ</given-names></name>
<name><surname>Center</surname> <given-names>I</given-names></name>
<name><surname>Committee</surname> <given-names>NM</given-names></name>
</person-group>. 
<article-title>Chinese expert consensus on selective internal radiation therapy with yttrium-90 for primary and metastatic hepatocellular carcinoma</article-title>. <source>Zhonghua Gan Zang Bing Za Zhi= Zhonghua Ganzangbing Zazhi= Chin J Hepatol</source>. (<year>2021</year>) <volume>29</volume>:<page-range>648&#x2013;58</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.3760/cma.j.cn501113-20210302-00103</pub-id>, PMID: <pub-id pub-id-type="pmid">34371535</pub-id>
</mixed-citation>
</ref>
<ref id="B10">
<label>10</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Camacho</surname> <given-names>JC</given-names></name>
<name><surname>Moncayo</surname> <given-names>V</given-names></name>
<name><surname>Kokabi</surname> <given-names>N</given-names></name>
<name><surname>Reavey</surname> <given-names>HE</given-names></name>
<name><surname>Galt</surname> <given-names>JR</given-names></name>
<name><surname>Yamada</surname> <given-names>K</given-names></name>
<etal/>
</person-group>. 
<article-title>(90)Y radioembolization: multimodality imaging pattern approach with angiographic correlation for optimized target therapy delivery</article-title>. <source>Radiographics</source>. (<year>2015</year>) <volume>35</volume>:<page-range>1602&#x2013;18</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1148/rg.2015140314</pub-id>, PMID: <pub-id pub-id-type="pmid">26230755</pub-id>
</mixed-citation>
</ref>
<ref id="B11">
<label>11</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Lee</surname> <given-names>SY</given-names></name>
<name><surname>Jeon</surname> <given-names>SI</given-names></name>
<name><surname>Jung</surname> <given-names>S</given-names></name>
<name><surname>Chung</surname> <given-names>IJ</given-names></name>
<name><surname>Ahn</surname> <given-names>C-H</given-names></name>
</person-group>. 
<article-title>Targeted multimodal imaging modalities</article-title>. <source>Adv Drug Deliv Rev</source>. (<year>2014</year>) <volume>76</volume>:<fpage>60</fpage>&#x2013;<lpage>78</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.addr.2014.07.009</pub-id>, PMID: <pub-id pub-id-type="pmid">25064554</pub-id>
</mixed-citation>
</ref>
<ref id="B12">
<label>12</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Schoenberger</surname> <given-names>H</given-names></name>
<name><surname>Chong</surname> <given-names>N</given-names></name>
<name><surname>Fetzer</surname> <given-names>DT</given-names></name>
<name><surname>Rich</surname> <given-names>NE</given-names></name>
<name><surname>Yokoo</surname> <given-names>T</given-names></name>
<name><surname>Khatri</surname> <given-names>G</given-names></name>
<etal/>
</person-group>. 
<article-title>Dynamic changes in ultrasound quality for hepatocellular carcinoma screening in patients with cirrhosis</article-title>. <source>Clin Gastroenterol Hepatol</source>. (<year>2022</year>) <volume>20</volume>:<fpage>1561</fpage>&#x2013;<lpage>9.e4</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.cgh.2021.06.012</pub-id>, PMID: <pub-id pub-id-type="pmid">34119640</pub-id>
</mixed-citation>
</ref>
<ref id="B13">
<label>13</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Bruix</surname> <given-names>J</given-names></name>
<name><surname>Sherman</surname> <given-names>M</given-names></name>
</person-group>. 
<article-title>Management of hepatocellular carcinoma: an update&#x394;&#x3c3;</article-title>. <source>Hepatology</source>. (<year>2011</year>) <volume>53</volume>:<page-range>1020&#x2013;2</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/hep.24199</pub-id>, PMID: <pub-id pub-id-type="pmid">21374666</pub-id>
</mixed-citation>
</ref>
<ref id="B14">
<label>14</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Sparchez</surname> <given-names>Z</given-names></name>
<name><surname>Craciun</surname> <given-names>R</given-names></name>
<name><surname>Caraiani</surname> <given-names>C</given-names></name>
<name><surname>Horhat</surname> <given-names>A</given-names></name>
<name><surname>Nenu</surname> <given-names>I</given-names></name>
<name><surname>Procopet</surname> <given-names>B</given-names></name>
<etal/>
</person-group>. 
<article-title>Ultrasound or sectional imaging techniques as screening tools for hepatocellular carcinoma: fall forward or move forward</article-title>? <source>J Clin Med</source>. (<year>2021</year>) <volume>10</volume>. doi:&#xa0;<pub-id pub-id-type="doi">10.3390/jcm10050903</pub-id>, PMID: <pub-id pub-id-type="pmid">33668839</pub-id>
</mixed-citation>
</ref>
<ref id="B15">
<label>15</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Hawley</surname> <given-names>J</given-names></name>
<name><surname>Tang</surname> <given-names>Y</given-names></name>
<name><surname>Sj&#xf6;str&#xf6;m</surname> <given-names>A</given-names></name>
<name><surname>Fuentes-Alburo</surname> <given-names>A</given-names></name>
<name><surname>Tranquart</surname> <given-names>F</given-names></name>
</person-group>. 
<article-title>The clinical utility of liver-specific ultrasound contrast agents during hepatocellular carcinoma imaging</article-title>. <source>Ultrasound Med Biol</source>. (<year>2025</year>) <volume>51</volume>:<page-range>415&#x2013;27</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.ultrasmedbio.2024.10.011</pub-id>, PMID: <pub-id pub-id-type="pmid">39674715</pub-id>
</mixed-citation>
</ref>
<ref id="B16">
<label>16</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Delaney</surname> <given-names>LJ</given-names></name>
<name><surname>Tantawi</surname> <given-names>M</given-names></name>
<name><surname>Wessner</surname> <given-names>CE</given-names></name>
<name><surname>MaChado</surname> <given-names>P</given-names></name>
<name><surname>Forsberg</surname> <given-names>F</given-names></name>
<name><surname>Lyshchik</surname> <given-names>A</given-names></name>
<etal/>
</person-group>. 
<article-title>Predicting long-term hepatocellular carcinoma response to transarterial radioembolization using contrast-enhanced ultrasound: initial experiences</article-title>. <source>Ultrasound Med Biol</source>. (<year>2021</year>) <volume>47</volume>:<page-range>2523&#x2013;31</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.ultrasmedbio.2021.05.006</pub-id>, PMID: <pub-id pub-id-type="pmid">34130880</pub-id>
</mixed-citation>
</ref>
<ref id="B17">
<label>17</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Yoon</surname> <given-names>JH</given-names></name>
<name><surname>Chang</surname> <given-names>W</given-names></name>
<name><surname>Kim</surname> <given-names>YK</given-names></name>
<name><surname>Lee</surname> <given-names>CH</given-names></name>
<name><surname>Kim</surname> <given-names>JW</given-names></name>
<name><surname>Park</surname> <given-names>BJ</given-names></name>
<etal/>
</person-group>. 
<article-title>Comparison of gadoxetic acid-enhanced liver magnetic resonance imaging and contrast-enhanced computed tomography for the noninvasive diagnosis of hepatocellular carcinoma</article-title>. <source>Liver Cancer</source>. (<year>2025</year>) <volume>14</volume>:<page-range>638&#x2013;50</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1159/000545965</pub-id>, PMID: <pub-id pub-id-type="pmid">40487794</pub-id>
</mixed-citation>
</ref>
<ref id="B18">
<label>18</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Kierans</surname> <given-names>AS</given-names></name>
<name><surname>Kang</surname> <given-names>SK</given-names></name>
<name><surname>Rosenkrantz</surname> <given-names>AB</given-names></name>
</person-group>. 
<article-title>The diagnostic performance of dynamic contrast-enhanced MR imaging for detection of small hepatocellular carcinoma measuring up to 2 cm: A meta-analysis</article-title>. <source>Radiology</source>. (<year>2016</year>) <volume>278</volume>:<fpage>82</fpage>&#x2013;<lpage>94</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1148/radiol.2015150177</pub-id>, PMID: <pub-id pub-id-type="pmid">26098460</pub-id>
</mixed-citation>
</ref>
<ref id="B19">
<label>19</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Silva</surname> <given-names>AC</given-names></name>
<name><surname>Morse</surname> <given-names>BG</given-names></name>
<name><surname>Hara</surname> <given-names>AK</given-names></name>
<name><surname>Paden</surname> <given-names>RG</given-names></name>
<name><surname>Hongo</surname> <given-names>N</given-names></name>
<name><surname>Pavlicek</surname> <given-names>W</given-names></name>
</person-group>. 
<article-title>Dual-energy (spectral) CT: applications in abdominal imaging</article-title>. <source>Radiographics</source>. (<year>2011</year>) <volume>31</volume>:<page-range>1031&#x2013;46</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1148/rg.314105159</pub-id>, PMID: <pub-id pub-id-type="pmid">21768237</pub-id>
</mixed-citation>
</ref>
<ref id="B20">
<label>20</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Altenbernd</surname> <given-names>J</given-names></name>
<name><surname>Wetter</surname> <given-names>A</given-names></name>
<name><surname>Forsting</surname> <given-names>M</given-names></name>
<name><surname>Umutlu</surname> <given-names>L</given-names></name>
</person-group>. 
<article-title>Treatment response after radioembolisation in patients with hepatocellular carcinoma-An evaluation with dual energy computed-tomography</article-title>. <source>Eur J Radiol Open</source>. (<year>2016</year>) <volume>3</volume>:<page-range>230&#x2013;5</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.ejro.2016.08.002</pub-id>, PMID: <pub-id pub-id-type="pmid">27622200</pub-id>
</mixed-citation>
</ref>
<ref id="B21">
<label>21</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Zhong</surname> <given-names>H</given-names></name>
<name><surname>Zhang</surname> <given-names>Y</given-names></name>
<name><surname>Zhu</surname> <given-names>G</given-names></name>
<name><surname>Zheng</surname> <given-names>X</given-names></name>
<name><surname>Wang</surname> <given-names>J</given-names></name>
<name><surname>Kang</surname> <given-names>J</given-names></name>
<etal/>
</person-group>. 
<article-title>Preoperative prediction of microvascular invasion and relapse-free survival in hepatocellular Carcinoma &#x2265;3 cm using CT radiomics: Development and external validation</article-title>. <source>BMC Med Imaging</source>. (<year>2025</year>) <volume>25</volume>:<fpage>141</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1186/s12880-025-01677-2</pub-id>, PMID: <pub-id pub-id-type="pmid">40312321</pub-id>
</mixed-citation>
</ref>
<ref id="B22">
<label>22</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Hayano</surname> <given-names>K</given-names></name>
<name><surname>Desai</surname> <given-names>GS</given-names></name>
<name><surname>Kambadakone</surname> <given-names>AR</given-names></name>
<name><surname>Fuentes</surname> <given-names>JM</given-names></name>
<name><surname>Tanabe</surname> <given-names>KK</given-names></name>
<name><surname>Sahani</surname> <given-names>DV</given-names></name>
</person-group>. 
<article-title>Quantitative characterization of hepatocellular carcinoma and metastatic liver tumor by CT perfusion</article-title>. <source>Cancer Imaging</source>. (<year>2013</year>) <volume>13</volume>:<page-range>512&#x2013;9</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1102/1470-7330.2013.0040</pub-id>, PMID: <pub-id pub-id-type="pmid">24334461</pub-id>
</mixed-citation>
</ref>
<ref id="B23">
<label>23</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Kalarakis</surname> <given-names>G</given-names></name>
<name><surname>Perisinakis</surname> <given-names>K</given-names></name>
<name><surname>Akoumianakis</surname> <given-names>E</given-names></name>
<name><surname>Karageorgiou</surname> <given-names>I</given-names></name>
<name><surname>Hatzidakis</surname> <given-names>A</given-names></name>
</person-group>. 
<article-title>CT liver perfusion in patients with hepatocellular carcinoma: can we modify acquisition protocol to reduce patient exposure</article-title>? <source>Eur Radiol</source>. (<year>2021</year>) <volume>31</volume>:<page-range>1410&#x2013;9</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1007/s00330-020-07206-9</pub-id>, PMID: <pub-id pub-id-type="pmid">32876834</pub-id>
</mixed-citation>
</ref>
<ref id="B24">
<label>24</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Reiner</surname> <given-names>CS</given-names></name>
<name><surname>Morsbach</surname> <given-names>F</given-names></name>
<name><surname>Sah</surname> <given-names>BR</given-names></name>
<name><surname>Puippe</surname> <given-names>G</given-names></name>
<name><surname>Schaefer</surname> <given-names>N</given-names></name>
<name><surname>Pfammatter</surname> <given-names>T</given-names></name>
<etal/>
</person-group>. 
<article-title>Early treatment response evaluation after yttrium-90 radioembolization of liver Malignancy with CT perfusion</article-title>. <source>J Vasc Interv Radiol</source>. (<year>2014</year>) <volume>25</volume>:<page-range>747&#x2013;59</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.jvir.2014.01.025</pub-id>, PMID: <pub-id pub-id-type="pmid">24630751</pub-id>
</mixed-citation>
</ref>
<ref id="B25">
<label>25</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Cruite</surname> <given-names>I</given-names></name>
<name><surname>Schroeder</surname> <given-names>M</given-names></name>
<name><surname>Merkle</surname> <given-names>EM</given-names></name>
<name><surname>Sirlin</surname> <given-names>CB</given-names></name>
</person-group>. 
<article-title>Gadoxetate disodium-enhanced MRI of the liver: part 2, protocol optimization and lesion appearance in the cirrhotic liver</article-title>. <source>AJR Am J Roentgenol</source>. (<year>2010</year>) <volume>195</volume>:<fpage>29</fpage>&#x2013;<lpage>41</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.2214/AJR.10.4538</pub-id>, PMID: <pub-id pub-id-type="pmid">20566795</pub-id>
</mixed-citation>
</ref>
<ref id="B26">
<label>26</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Guo</surname> <given-names>J</given-names></name>
<name><surname>Seo</surname> <given-names>Y</given-names></name>
<name><surname>Ren</surname> <given-names>S</given-names></name>
<name><surname>Hong</surname> <given-names>S</given-names></name>
<name><surname>Lee</surname> <given-names>D</given-names></name>
<name><surname>Kim</surname> <given-names>S</given-names></name>
<etal/>
</person-group>. 
<article-title>Diagnostic performance of contrast-enhanced multidetector computed tomography and gadoxetic acid disodium-enhanced magnetic resonance imaging in detecting hepatocellular carcinoma: direct comparison and a meta-analysis</article-title>. <source>Abdom Radiol (NY)</source>. (<year>2016</year>) <volume>41</volume>:<page-range>1960&#x2013;72</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1007/s00261-016-0807-7</pub-id>, PMID: <pub-id pub-id-type="pmid">27318936</pub-id>
</mixed-citation>
</ref>
<ref id="B27">
<label>27</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Bharwani</surname> <given-names>N</given-names></name>
<name><surname>Koh</surname> <given-names>DM</given-names></name>
</person-group>. 
<article-title>Diffusion-weighted imaging of the liver: an update</article-title>. <source>Cancer Imaging</source>. (<year>2013</year>) <volume>13</volume>:<page-range>171&#x2013;85</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1102/1470-7330.2013.0019</pub-id>, PMID: <pub-id pub-id-type="pmid">23598460</pub-id>
</mixed-citation>
</ref>
<ref id="B28">
<label>28</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Hectors</surname> <given-names>SJ</given-names></name>
<name><surname>Lewis</surname> <given-names>S</given-names></name>
<name><surname>Kennedy</surname> <given-names>P</given-names></name>
<name><surname>Bane</surname> <given-names>O</given-names></name>
<name><surname>Said</surname> <given-names>D</given-names></name>
<name><surname>Segall</surname> <given-names>M</given-names></name>
<etal/>
</person-group>. 
<article-title>Assessment of hepatocellular carcinoma response to (90)Y radioembolization using dynamic contrast material-enhanced MRI and intravoxel incoherent motion diffusion-weighted imaging</article-title>. <source>Radiol Imaging Cancer</source>. (<year>2020</year>) <volume>2</volume>:<elocation-id>e190094</elocation-id>. doi:&#xa0;<pub-id pub-id-type="doi">10.1148/rycan.2020190094</pub-id>, PMID: <pub-id pub-id-type="pmid">32803165</pub-id>
</mixed-citation>
</ref>
<ref id="B29">
<label>29</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Taouli</surname> <given-names>B</given-names></name>
<name><surname>Johnson</surname> <given-names>RS</given-names></name>
<name><surname>Hajdu</surname> <given-names>CH</given-names></name>
<name><surname>Oei</surname> <given-names>MT</given-names></name>
<name><surname>Merad</surname> <given-names>M</given-names></name>
<name><surname>Yee</surname> <given-names>H</given-names></name>
<etal/>
</person-group>. 
<article-title>Hepatocellular carcinoma: perfusion quantification with dynamic contrast-enhanced MRI</article-title>. <source>AJR Am J Roentgenol</source>. (<year>2013</year>) <volume>201</volume>:<fpage>795</fpage>&#x2013;<lpage>800</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.2214/AJR.12.9798</pub-id>, PMID: <pub-id pub-id-type="pmid">24059368</pub-id>
</mixed-citation>
</ref>
<ref id="B30">
<label>30</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Weiss</surname> <given-names>J</given-names></name>
<name><surname>Ruff</surname> <given-names>C</given-names></name>
<name><surname>Grosse</surname> <given-names>U</given-names></name>
<name><surname>Gr&#xf6;zinger</surname> <given-names>G</given-names></name>
<name><surname>Horger</surname> <given-names>M</given-names></name>
<name><surname>Nikolaou</surname> <given-names>K</given-names></name>
<etal/>
</person-group>. 
<article-title>Assessment of hepatic perfusion using GRASP MRI: bringing liver MRI on a new level</article-title>. <source>Invest Radiol</source>. (<year>2019</year>) <volume>54</volume>:<page-range>737&#x2013;43</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1097/RLI.0000000000000586</pub-id>, PMID: <pub-id pub-id-type="pmid">31206392</pub-id>
</mixed-citation>
</ref>
<ref id="B31">
<label>31</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Cheung</surname> <given-names>AL</given-names></name>
<name><surname>Zhang</surname> <given-names>L</given-names></name>
<name><surname>Liu</surname> <given-names>C</given-names></name>
<name><surname>Li</surname> <given-names>T</given-names></name>
<name><surname>Cheung</surname> <given-names>AH</given-names></name>
<name><surname>Leung</surname> <given-names>C</given-names></name>
<etal/>
</person-group>. 
<article-title>Evaluation of multisource adaptive MRI fusion for gross tumor volume delineation of hepatocellular carcinoma</article-title>. <source>Front Oncol</source>. (<year>2022</year>) <volume>12</volume>:<elocation-id>816678</elocation-id>. doi:&#xa0;<pub-id pub-id-type="doi">10.3389/fonc.2022.816678</pub-id>, PMID: <pub-id pub-id-type="pmid">35280780</pub-id>
</mixed-citation>
</ref>
<ref id="B32">
<label>32</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Zhang</surname> <given-names>L</given-names></name>
<name><surname>Yin</surname> <given-names>FF</given-names></name>
<name><surname>Lu</surname> <given-names>K</given-names></name>
<name><surname>Moore</surname> <given-names>B</given-names></name>
<name><surname>Han</surname> <given-names>S</given-names></name>
<name><surname>Cai</surname> <given-names>J</given-names></name>
</person-group>. 
<article-title>Improving liver tumor image contrast and synthesizing novel tissue contrasts by adaptive multiparametric MRI fusion</article-title>. <source>Precis Radiat Oncol</source>. (<year>2022</year>) <volume>6</volume>:<page-range>190&#x2013;8</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/pro6.1167</pub-id>, PMID: <pub-id pub-id-type="pmid">36590077</pub-id>
</mixed-citation>
</ref>
<ref id="B33">
<label>33</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Kokabi</surname> <given-names>N</given-names></name>
<name><surname>Camacho</surname> <given-names>JC</given-names></name>
<name><surname>Xing</surname> <given-names>M</given-names></name>
<name><surname>Qiu</surname> <given-names>D</given-names></name>
<name><surname>Kitajima</surname> <given-names>H</given-names></name>
<name><surname>Mittal</surname> <given-names>PK</given-names></name>
<etal/>
</person-group>. 
<article-title>Apparent diffusion coefficient quantification as an early imaging biomarker of response and predictor of survival following yttrium-90 radioembolization for unresectable infiltrative hepatocellular carcinoma with portal vein thrombosis</article-title>. <source>Abdom Imaging</source>. (<year>2014</year>) <volume>39</volume>:<page-range>969&#x2013;78</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1007/s00261-014-0127-8</pub-id>, PMID: <pub-id pub-id-type="pmid">24740759</pub-id>
</mixed-citation>
</ref>
<ref id="B34">
<label>34</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Kim</surname> <given-names>S</given-names></name>
<name><surname>Mannelli</surname> <given-names>L</given-names></name>
<name><surname>Hajdu</surname> <given-names>CH</given-names></name>
<name><surname>Babb</surname> <given-names>JS</given-names></name>
<name><surname>Clark</surname> <given-names>TW</given-names></name>
<name><surname>Hecht</surname> <given-names>EM</given-names></name>
<etal/>
</person-group>. 
<article-title>Hepatocellular carcinoma: assessment of response to transarterial chemoembolization with image subtraction</article-title>. <source>J Magn Reson Imaging</source>. (<year>2010</year>) <volume>31</volume>:<page-range>348&#x2013;55</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/jmri.22038</pub-id>, PMID: <pub-id pub-id-type="pmid">20099348</pub-id>
</mixed-citation>
</ref>
<ref id="B35">
<label>35</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Maleux</surname> <given-names>G</given-names></name>
<name><surname>Heye</surname> <given-names>S</given-names></name>
<name><surname>Vaninbroukx</surname> <given-names>J</given-names></name>
<name><surname>Deroose</surname> <given-names>C</given-names></name>
</person-group>. 
<article-title>Angiographic considerations in patients undergoing liver-directed radioembolization with 90Y microspheres</article-title>. <source>Acta Gastroenterol Belg</source>. (<year>2010</year>) <volume>73</volume>:<page-range>489&#x2013;96</page-range>., PMID: <pub-id pub-id-type="pmid">21299160</pub-id>
</mixed-citation>
</ref>
<ref id="B36">
<label>36</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Hiatt</surname> <given-names>JR</given-names></name>
<name><surname>Gabbay</surname> <given-names>J</given-names></name>
<name><surname>Busuttil</surname> <given-names>RW</given-names></name>
</person-group>. 
<article-title>Surgical anatomy of the hepatic arteries in 1000 cases</article-title>. <source>Ann Surg</source>. (<year>1994</year>) <volume>220</volume>:<page-range>50&#x2013;2</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1097/00000658-199407000-00008</pub-id>, PMID: <pub-id pub-id-type="pmid">8024358</pub-id>
</mixed-citation>
</ref>
<ref id="B37">
<label>37</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Michels</surname> <given-names>NA</given-names></name>
</person-group>. 
<article-title>Newer anatomy of the liver and its variant blood supply and collateral circulation</article-title>. <source>Am J Surg</source>. (<year>1966</year>) <volume>112</volume>:<page-range>337&#x2013;47</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/0002-9610(66)90201-7</pub-id>, PMID: <pub-id pub-id-type="pmid">5917302</pub-id>
</mixed-citation>
</ref>
<ref id="B38">
<label>38</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Liu</surname> <given-names>DM</given-names></name>
<name><surname>Salem</surname> <given-names>R</given-names></name>
<name><surname>Bui</surname> <given-names>JT</given-names></name>
<name><surname>Courtney</surname> <given-names>A</given-names></name>
<name><surname>Barakat</surname> <given-names>O</given-names></name>
<name><surname>Sergie</surname> <given-names>Z</given-names></name>
<etal/>
</person-group>. 
<article-title>Angiographic considerations in patients undergoing liver-directed therapy</article-title>. <source>J Vasc Interv Radiol</source>. (<year>2005</year>) <volume>16</volume>:<page-range>911&#x2013;35</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1097/01.RVI.0000164324.79242.B2</pub-id>, PMID: <pub-id pub-id-type="pmid">16002500</pub-id>
</mixed-citation>
</ref>
<ref id="B39">
<label>39</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Louie</surname> <given-names>JD</given-names></name>
<name><surname>Kothary</surname> <given-names>N</given-names></name>
<name><surname>Kuo</surname> <given-names>WT</given-names></name>
<name><surname>Hwang</surname> <given-names>GL</given-names></name>
<name><surname>Hofmann</surname> <given-names>LV</given-names></name>
<name><surname>Goris</surname> <given-names>ML</given-names></name>
<etal/>
</person-group>. 
<article-title>Incorporating cone-beam CT into the treatment planning for yttrium-90 radioembolization</article-title>. <source>J Vasc Interv Radiol</source>. (<year>2009</year>) <volume>20</volume>:<page-range>606&#x2013;13</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.jvir.2009.01.021</pub-id>, PMID: <pub-id pub-id-type="pmid">19345589</pub-id>
</mixed-citation>
</ref>
<ref id="B40">
<label>40</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Heusner</surname> <given-names>TA</given-names></name>
<name><surname>Hamami</surname> <given-names>ME</given-names></name>
<name><surname>Ertle</surname> <given-names>J</given-names></name>
<name><surname>Hahn</surname> <given-names>S</given-names></name>
<name><surname>Poeppel</surname> <given-names>T</given-names></name>
<name><surname>Hilgard</surname> <given-names>P</given-names></name>
<etal/>
</person-group>. 
<article-title>Angiography-based C-arm CT for the assessment of extrahepatic shunting before radioembolization</article-title>. <source>Rofo</source>. (<year>2010</year>) <volume>182</volume>:<page-range>603&#x2013;8</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1055/s-0029-1245192</pub-id>, PMID: <pub-id pub-id-type="pmid">20183775</pub-id>
</mixed-citation>
</ref>
<ref id="B41">
<label>41</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Rhee</surname> <given-names>TK</given-names></name>
<name><surname>Omary</surname> <given-names>RA</given-names></name>
<name><surname>Gates</surname> <given-names>V</given-names></name>
<name><surname>Mounajjed</surname> <given-names>T</given-names></name>
<name><surname>Larson</surname> <given-names>AC</given-names></name>
<name><surname>Barakat</surname> <given-names>O</given-names></name>
<etal/>
</person-group>. 
<article-title>The effect of catheter-directed CT angiography on yttrium-90 radioembolization treatment of hepatocellular carcinoma</article-title>. <source>J Vasc Interv Radiol</source>. (<year>2005</year>) <volume>16</volume>:<page-range>1085&#x2013;91</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1097/01.RVI.0000177063.92678.21</pub-id>, PMID: <pub-id pub-id-type="pmid">16105920</pub-id>
</mixed-citation>
</ref>
<ref id="B42">
<label>42</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Gr&#xf6;zinger</surname> <given-names>G</given-names></name>
<name><surname>Kupferschl&#xe4;ger</surname> <given-names>J</given-names></name>
<name><surname>Dittmann</surname> <given-names>H</given-names></name>
<name><surname>Maurer</surname> <given-names>M</given-names></name>
<name><surname>Grosse</surname> <given-names>U</given-names></name>
<name><surname>la Foug&#xe8;re</surname> <given-names>C</given-names></name>
<etal/>
</person-group>. 
<article-title>Assessment of the parenchymal blood volume by C-arm computed tomography for radioembolization dosimetry</article-title>. <source>Eur J Radiol</source>. (<year>2016</year>) <volume>85</volume>:<page-range>1525&#x2013;31</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.ejrad.2016.06.005</pub-id>, PMID: <pub-id pub-id-type="pmid">27501884</pub-id>
</mixed-citation>
</ref>
<ref id="B43">
<label>43</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Jafargholi Rangraz</surname> <given-names>E</given-names></name>
<name><surname>Coudyzer</surname> <given-names>W</given-names></name>
<name><surname>Maleux</surname> <given-names>G</given-names></name>
<name><surname>Baete</surname> <given-names>K</given-names></name>
<name><surname>Deroose</surname> <given-names>CM</given-names></name>
<name><surname>Nuyts</surname> <given-names>J</given-names></name>
</person-group>. 
<article-title>Multi-modal image analysis for semi-automatic segmentation of the total liver and liver arterial perfusion territories for radioembolization</article-title>. <source>EJNMMI Res</source>. (<year>2019</year>) <volume>9</volume>:<fpage>19</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1186/s13550-019-0485-x</pub-id>, PMID: <pub-id pub-id-type="pmid">30788640</pub-id>
</mixed-citation>
</ref>
<ref id="B44">
<label>44</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Tanaka</surname> <given-names>T</given-names></name>
<name><surname>Arai</surname> <given-names>Y</given-names></name>
<name><surname>Inaba</surname> <given-names>Y</given-names></name>
<name><surname>Inoue</surname> <given-names>M</given-names></name>
<name><surname>Nishiofuku</surname> <given-names>H</given-names></name>
<name><surname>Anai</surname> <given-names>H</given-names></name>
<etal/>
</person-group>. 
<article-title>Current role of hybrid CT/angiography system compared with C-arm cone beam CT for interventional oncology</article-title>. <source>Br J Radiol</source>. (<year>2014</year>) <volume>87</volume>:<fpage>20140126</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1259/bjr.20140126</pub-id>, PMID: <pub-id pub-id-type="pmid">24968749</pub-id>
</mixed-citation>
</ref>
<ref id="B45">
<label>45</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Lionberg</surname> <given-names>A</given-names></name>
<name><surname>Nijhawan</surname> <given-names>K</given-names></name>
<name><surname>Navuluri</surname> <given-names>R</given-names></name>
<name><surname>Zangan</surname> <given-names>S</given-names></name>
<name><surname>Van Ha</surname> <given-names>T</given-names></name>
<name><surname>Funaki</surname> <given-names>B</given-names></name>
<etal/>
</person-group>. 
<article-title>Hybrid angiography-CT for transarterial radioembolization: a pictorial essay</article-title>. <source>Abdom Radiol (NY)</source>. (<year>2021</year>) <volume>46</volume>:<page-range>2850&#x2013;4</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1007/s00261-020-02914-8</pub-id>, PMID: <pub-id pub-id-type="pmid">33394098</pub-id>
</mixed-citation>
</ref>
<ref id="B46">
<label>46</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Campbell</surname> <given-names>GS</given-names></name>
<name><surname>Reed</surname> <given-names>DK</given-names></name>
<name><surname>Desai</surname> <given-names>A</given-names></name>
<name><surname>S</surname> <given-names>TL</given-names></name>
</person-group>. 
<article-title>Liver tumor enhancement at hybrid angio-CT and comparison with tumor and hepatic parenchymal distribution of yttrium-90 microspheres by positron emission tomography</article-title>. <source>Cureus</source>. (<year>2023</year>) <volume>15</volume>:<elocation-id>e49861</elocation-id>. doi:&#xa0;<pub-id pub-id-type="doi">10.7759/cureus.49861</pub-id>, PMID: <pub-id pub-id-type="pmid">38169929</pub-id>
</mixed-citation>
</ref>
<ref id="B47">
<label>47</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Ahmadzadehfar</surname> <given-names>H</given-names></name>
<name><surname>Sabet</surname> <given-names>A</given-names></name>
<name><surname>Biermann</surname> <given-names>K</given-names></name>
<name><surname>Muckle</surname> <given-names>M</given-names></name>
<name><surname>Brockmann</surname> <given-names>H</given-names></name>
<name><surname>Kuhl</surname> <given-names>C</given-names></name>
<etal/>
</person-group>. 
<article-title>The significance of 99mTc-MAA SPECT/CT liver perfusion imaging in treatment planning for 90Y-microsphere selective internal radiation treatment</article-title>. <source>J Nucl Med</source>. (<year>2010</year>) <volume>51</volume>:<page-range>1206&#x2013;12</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.2967/jnumed.109.074559</pub-id>, PMID: <pub-id pub-id-type="pmid">20660379</pub-id>
</mixed-citation>
</ref>
<ref id="B48">
<label>48</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Hamami</surname> <given-names>ME</given-names></name>
<name><surname>Poeppel</surname> <given-names>TD</given-names></name>
<name><surname>M&#xfc;ller</surname> <given-names>S</given-names></name>
<name><surname>Heusner</surname> <given-names>T</given-names></name>
<name><surname>Bockisch</surname> <given-names>A</given-names></name>
<name><surname>Hilgard</surname> <given-names>P</given-names></name>
<etal/>
</person-group>. 
<article-title>SPECT/CT with 99mTc-MAA in radioembolization with 90Y microspheres in patients with hepatocellular cancer</article-title>. <source>J Nucl Med</source>. (<year>2009</year>) <volume>50</volume>:<page-range>688&#x2013;92</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.2967/jnumed.108.058347</pub-id>, PMID: <pub-id pub-id-type="pmid">19372479</pub-id>
</mixed-citation>
</ref>
<ref id="B49">
<label>49</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Lenoir</surname> <given-names>L</given-names></name>
<name><surname>Edeline</surname> <given-names>J</given-names></name>
<name><surname>Rolland</surname> <given-names>Y</given-names></name>
<name><surname>Pracht</surname> <given-names>M</given-names></name>
<name><surname>Raoul</surname> <given-names>JL</given-names></name>
<name><surname>Ardisson</surname> <given-names>V</given-names></name>
<etal/>
</person-group>. 
<article-title>Usefulness and pitfalls of MAA SPECT/CT in identifying digestive extrahepatic uptake when planning liver radioembolization</article-title>. <source>Eur J Nucl Med Mol Imaging</source>. (<year>2012</year>) <volume>39</volume>:<page-range>872&#x2013;80</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1007/s00259-011-2033-4</pub-id>, PMID: <pub-id pub-id-type="pmid">22237844</pub-id>
</mixed-citation>
</ref>
<ref id="B50">
<label>50</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Garin</surname> <given-names>E</given-names></name>
<name><surname>Lenoir</surname> <given-names>L</given-names></name>
<name><surname>Rolland</surname> <given-names>Y</given-names></name>
<name><surname>Edeline</surname> <given-names>J</given-names></name>
<name><surname>Mesbah</surname> <given-names>H</given-names></name>
<name><surname>Laffont</surname> <given-names>S</given-names></name>
<etal/>
</person-group>. 
<article-title>Dosimetry based on 99mTc-macroaggregated albumin SPECT/CT accurately predicts tumor response and survival in hepatocellular carcinoma patients treated with 90Y-loaded glass microspheres: preliminary results</article-title>. <source>J Nucl Med</source>. (<year>2012</year>) <volume>53</volume>:<page-range>255&#x2013;63</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.2967/jnumed.111.094235</pub-id>, PMID: <pub-id pub-id-type="pmid">22302962</pub-id>
</mixed-citation>
</ref>
<ref id="B51">
<label>51</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Atassi</surname> <given-names>B</given-names></name>
<name><surname>Bangash</surname> <given-names>AK</given-names></name>
<name><surname>Bahrani</surname> <given-names>A</given-names></name>
<name><surname>Pizzi</surname> <given-names>G</given-names></name>
<name><surname>Lewandowski</surname> <given-names>RJ</given-names></name>
<name><surname>Ryu</surname> <given-names>RK</given-names></name>
<etal/>
</person-group>. 
<article-title>Multimodality imaging following 90Y radioembolization: a comprehensive review and pictorial essay</article-title>. <source>Radiographics</source>. (<year>2008</year>) <volume>28</volume>:<fpage>81</fpage>&#x2013;<lpage>99</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1148/rg.281065721</pub-id>, PMID: <pub-id pub-id-type="pmid">18203932</pub-id>
</mixed-citation>
</ref>
<ref id="B52">
<label>52</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Uliel</surname> <given-names>L</given-names></name>
<name><surname>Royal</surname> <given-names>HD</given-names></name>
<name><surname>Darcy</surname> <given-names>MD</given-names></name>
<name><surname>Zuckerman</surname> <given-names>DA</given-names></name>
<name><surname>Sharma</surname> <given-names>A</given-names></name>
<name><surname>Saad</surname> <given-names>NE</given-names></name>
</person-group>. 
<article-title>From the angio suite to the &#x3b3;-camera: vascular mapping and 99mTc-MAA hepatic perfusion imaging before liver radioembolization&#x2013;a comprehensive pictorial review</article-title>. <source>J Nucl Med</source>. (<year>2012</year>) <volume>53</volume>:<page-range>1736&#x2013;47</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.2967/jnumed.112.105361</pub-id>, PMID: <pub-id pub-id-type="pmid">23124868</pub-id>
</mixed-citation>
</ref>
<ref id="B53">
<label>53</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Jafargholi Rangraz</surname> <given-names>E</given-names></name>
<name><surname>Tang</surname> <given-names>X</given-names></name>
<name><surname>Van Laeken</surname> <given-names>C</given-names></name>
<name><surname>Maleux</surname> <given-names>G</given-names></name>
<name><surname>Dekervel</surname> <given-names>J</given-names></name>
<name><surname>Van Cutsem</surname> <given-names>E</given-names></name>
<etal/>
</person-group>. 
<article-title>Quantitative comparison of pre-treatment predictive and post-treatment measured dosimetry for selective internal radiation therapy using cone-beam CT for tumor and liver perfusion territory definition</article-title>. <source>EJNMMI Res</source>. (<year>2020</year>) <volume>10</volume>:<fpage>94</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1186/s13550-020-00675-5</pub-id>, PMID: <pub-id pub-id-type="pmid">32797332</pub-id>
</mixed-citation>
</ref>
<ref id="B54">
<label>54</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Wondergem</surname> <given-names>M</given-names></name>
<name><surname>Smits</surname> <given-names>ML</given-names></name>
<name><surname>Elschot</surname> <given-names>M</given-names></name>
<name><surname>De Jong</surname> <given-names>HW</given-names></name>
<name><surname>Verkooijen</surname> <given-names>HM</given-names></name>
<name><surname>Van Den Bosch</surname> <given-names>MA</given-names></name>
<etal/>
</person-group>. 
<article-title>99mTc-macroaggregated albumin poorly predicts the intrahepatic distribution of 90Y resin microspheres in hepatic radioembolization</article-title>. <source>J Nucl Med</source>. (<year>2013</year>) <volume>54</volume>:<page-range>1294&#x2013;301</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.2967/jnumed.112.117614</pub-id>, PMID: <pub-id pub-id-type="pmid">23749996</pub-id>
</mixed-citation>
</ref>
<ref id="B55">
<label>55</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Debebe</surname> <given-names>SA</given-names></name>
<name><surname>Adjouadi</surname> <given-names>M</given-names></name>
<name><surname>Gulec</surname> <given-names>SA</given-names></name>
<name><surname>Franquiz</surname> <given-names>J</given-names></name>
<name><surname>McGoron</surname> <given-names>AJ</given-names></name>
</person-group>. 
<article-title>(90) Y SPECT/CT quantitative study and comparison of uptake with pretreatment (99 m) Tc-MAA SPECT/CT in radiomicrosphere therapy</article-title>. <source>J Appl Clin Med Phys</source>. (<year>2019</year>) <volume>20</volume>:<fpage>30</fpage>&#x2013;<lpage>42</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/acm2.12512</pub-id>, PMID: <pub-id pub-id-type="pmid">30628156</pub-id>
</mixed-citation>
</ref>
<ref id="B56">
<label>56</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Cheng</surname> <given-names>Y</given-names></name>
<name><surname>Wei</surname> <given-names>F</given-names></name>
<name><surname>Yu</surname> <given-names>H</given-names></name>
<name><surname>Ling</surname> <given-names>X</given-names></name>
<name><surname>Guo</surname> <given-names>B</given-names></name>
<name><surname>Shang</surname> <given-names>J</given-names></name>
<etal/>
</person-group>. 
<article-title>(99m)Tc-MAA SPECT/CT imaging before (90)Y-SIRT for reflecting the distribution of (90)Y resin microspheres in tumors and the liver: a comparison with (90)Y PET/CT verification imaging</article-title>. <source>Quant Imaging Med Surg</source>. (<year>2025</year>) <volume>15</volume>:<page-range>6272&#x2013;86</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.21037/qims-24-2232</pub-id>, PMID: <pub-id pub-id-type="pmid">40727337</pub-id>
</mixed-citation>
</ref>
<ref id="B57">
<label>57</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Demir</surname> <given-names>B</given-names></name>
<name><surname>Kucuk</surname> <given-names>NO</given-names></name>
<name><surname>Soydal</surname> <given-names>C</given-names></name>
<name><surname>Celebioglu</surname> <given-names>EC</given-names></name>
<name><surname>Inal</surname> <given-names>G</given-names></name>
<name><surname>Dursun</surname> <given-names>E</given-names></name>
<etal/>
</person-group>. 
<article-title>Comparative voxel-based dosimetry with pre-treatment Tc-99m SPECT/CT and post-treatment Y-90 PET/MRI for radioembolization with Y-90 microspheres</article-title>. <source>Ann Nucl Med</source>. (<year>2025</year>) <volume>39</volume>:<page-range>716&#x2013;31</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1007/s12149-025-02052-5</pub-id>, PMID: <pub-id pub-id-type="pmid">40266440</pub-id>
</mixed-citation>
</ref>
<ref id="B58">
<label>58</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Taswell</surname> <given-names>CS</given-names></name>
<name><surname>Studenski</surname> <given-names>M</given-names></name>
<name><surname>Pennix</surname> <given-names>T</given-names></name>
<name><surname>Stover</surname> <given-names>B</given-names></name>
<name><surname>Georgiou</surname> <given-names>M</given-names></name>
<name><surname>Venkat</surname> <given-names>S</given-names></name>
<etal/>
</person-group>. 
<article-title>For hepatocellular carcinoma treated with yttrium-90 microspheres, dose volumetrics on post-treatment bremsstrahlung SPECT/CT predict clinical outcomes</article-title>. <source>Cancers (Basel)</source>. (<year>2023</year>) <volume>15</volume>. doi:&#xa0;<pub-id pub-id-type="doi">10.3390/cancers15030645</pub-id>, PMID: <pub-id pub-id-type="pmid">36765603</pub-id>
</mixed-citation>
</ref>
<ref id="B59">
<label>59</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Elschot</surname> <given-names>M</given-names></name>
<name><surname>Vermolen</surname> <given-names>BJ</given-names></name>
<name><surname>Lam</surname> <given-names>MG</given-names></name>
<name><surname>De Keizer</surname> <given-names>B</given-names></name>
<name><surname>Van Den Bosch</surname> <given-names>MA</given-names></name>
<name><surname>De Jong</surname> <given-names>HW</given-names></name>
</person-group>. 
<article-title>Quantitative comparison of PET and Bremsstrahlung SPECT for imaging the <italic>in vivo</italic> yttrium-90 microsphere distribution after liver radioembolization</article-title>. <source>PloS One</source>. (<year>2013</year>) <volume>8</volume>:<elocation-id>e55742</elocation-id>. doi:&#xa0;<pub-id pub-id-type="doi">10.1371/journal.pone.0055742</pub-id>, PMID: <pub-id pub-id-type="pmid">23405207</pub-id>
</mixed-citation>
</ref>
<ref id="B60">
<label>60</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Filippi</surname> <given-names>L</given-names></name>
<name><surname>Schillaci</surname> <given-names>O</given-names></name>
<name><surname>Bagni</surname> <given-names>O</given-names></name>
</person-group>. 
<article-title>Recent advances in PET probes for hepatocellular carcinoma characterization</article-title>. <source>Expert Rev Med Dev</source>. (<year>2019</year>) <volume>16</volume>:<page-range>341&#x2013;50</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1080/17434440.2019.1608817</pub-id>, PMID: <pub-id pub-id-type="pmid">30990129</pub-id>
</mixed-citation>
</ref>
<ref id="B61">
<label>61</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Na</surname> <given-names>SJ</given-names></name>
<name><surname>Oh</surname> <given-names>JK</given-names></name>
<name><surname>Hyun</surname> <given-names>SH</given-names></name>
<name><surname>Lee</surname> <given-names>JW</given-names></name>
<name><surname>Hong</surname> <given-names>IK</given-names></name>
<name><surname>Song</surname> <given-names>BI</given-names></name>
<etal/>
</person-group>. 
<article-title>(18)F-FDG PET/CT can predict survival of advanced hepatocellular carcinoma patients: A multicenter retrospective cohort study</article-title>. <source>J Nucl Med</source>. (<year>2017</year>) <volume>58</volume>:<page-range>730&#x2013;6</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.2967/jnumed.116.182022</pub-id>, PMID: <pub-id pub-id-type="pmid">27789714</pub-id>
</mixed-citation>
</ref>
<ref id="B62">
<label>62</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Jreige</surname> <given-names>M</given-names></name>
<name><surname>Mitsakis</surname> <given-names>P</given-names></name>
<name><surname>Van Der Gucht</surname> <given-names>A</given-names></name>
<name><surname>Pomoni</surname> <given-names>A</given-names></name>
<name><surname>Silva-Monteiro</surname> <given-names>M</given-names></name>
<name><surname>Gnesin</surname> <given-names>S</given-names></name>
<etal/>
</person-group>. 
<article-title>(18)F-FDG PET/CT predicts survival after (90)Y transarterial radioembolization in unresectable hepatocellular carcinoma</article-title>. <source>Eur J Nucl Med Mol Imaging</source>. (<year>2017</year>) <volume>44</volume>:<page-range>1215&#x2013;22</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1007/s00259-017-3653-0</pub-id>, PMID: <pub-id pub-id-type="pmid">28233086</pub-id>
</mixed-citation>
</ref>
<ref id="B63">
<label>63</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Reizine</surname> <given-names>E</given-names></name>
<name><surname>Chalaye</surname> <given-names>J</given-names></name>
<name><surname>Mule</surname> <given-names>S</given-names></name>
<name><surname>Regnault</surname> <given-names>H</given-names></name>
<name><surname>Perrin</surname> <given-names>C</given-names></name>
<name><surname>Calderaro</surname> <given-names>J</given-names></name>
<etal/>
</person-group>. 
<article-title>Utility of early posttreatment PET/CT evaluation using FDG or (18)F-FCH to predict response to (90)Y radioembolization in patients with hepatocellular carcinoma</article-title>. <source>AJR Am J Roentgenol</source>. (<year>2022</year>) <volume>218</volume>:<page-range>359&#x2013;69</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.2214/AJR.21.26485</pub-id>, PMID: <pub-id pub-id-type="pmid">34494448</pub-id>
</mixed-citation>
</ref>
<ref id="B64">
<label>64</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Kao</surname> <given-names>YH</given-names></name>
<name><surname>Steinberg</surname> <given-names>JD</given-names></name>
<name><surname>Tay</surname> <given-names>YS</given-names></name>
<name><surname>Lim</surname> <given-names>GK</given-names></name>
<name><surname>Yan</surname> <given-names>J</given-names></name>
<name><surname>Townsend</surname> <given-names>DW</given-names></name>
<etal/>
</person-group>. 
<article-title>Post-radioembolization yttrium-90 PET/CT - part 2: dose-response and tumor predictive dosimetry for resin microspheres</article-title>. <source>EJNMMI Res</source>. (<year>2013</year>) <volume>3</volume>:<fpage>57</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1186/2191-219X-3-57</pub-id>, PMID: <pub-id pub-id-type="pmid">23885971</pub-id>
</mixed-citation>
</ref>
<ref id="B65">
<label>65</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Willowson</surname> <given-names>KP</given-names></name>
<name><surname>Tapner</surname> <given-names>M</given-names></name>
<name><surname>Bailey</surname> <given-names>DL</given-names></name>
</person-group>. 
<article-title>A multicentre comparison of quantitative (90)Y PET/CT for dosimetric purposes after radioembolization with resin microspheres: The QUEST Phantom Study</article-title>. <source>Eur J Nucl Med Mol Imaging</source>. (<year>2015</year>) <volume>42</volume>:<page-range>1202&#x2013;22</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1007/s00259-015-3059-9</pub-id>, PMID: <pub-id pub-id-type="pmid">25967868</pub-id>
</mixed-citation>
</ref>
<ref id="B66">
<label>66</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Roosen</surname> <given-names>J</given-names></name>
<name><surname>Klaassen</surname> <given-names>NJM</given-names></name>
<name><surname>Westlund Gotby</surname> <given-names>LEL</given-names></name>
<name><surname>Overduin</surname> <given-names>CG</given-names></name>
<name><surname>Verheij</surname> <given-names>M</given-names></name>
<name><surname>Konijnenberg</surname> <given-names>MW</given-names></name>
<etal/>
</person-group>. 
<article-title>To 1000 Gy and back again: a systematic review on dose-response evaluation in selective internal radiation therapy for primary and secondary liver cancer</article-title>. <source>Eur J Nucl Med Mol Imaging</source>. (<year>2021</year>) <volume>48</volume>:<page-range>3776&#x2013;90</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1007/s00259-021-05340-0</pub-id>, PMID: <pub-id pub-id-type="pmid">33839892</pub-id>
</mixed-citation>
</ref>
<ref id="B67">
<label>67</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Levillain</surname> <given-names>H</given-names></name>
<name><surname>Duran Derijckere</surname> <given-names>I</given-names></name>
<name><surname>Marin</surname> <given-names>G</given-names></name>
<name><surname>Guiot</surname> <given-names>T</given-names></name>
<name><surname>Vouche</surname> <given-names>M</given-names></name>
<name><surname>Reynaert</surname> <given-names>N</given-names></name>
<etal/>
</person-group>. 
<article-title>(90)Y-PET/CT-based dosimetry after selective internal radiation therapy predicts outcome in patients with liver metastases from colorectal cancer</article-title>. <source>EJNMMI Res</source>. (<year>2018</year>) <volume>8</volume>:<fpage>60</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1186/s13550-018-0419-z</pub-id>, PMID: <pub-id pub-id-type="pmid">30006851</pub-id>
</mixed-citation>
</ref>
<ref id="B68">
<label>68</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Linder</surname> <given-names>PM</given-names></name>
<name><surname>Lan</surname> <given-names>W</given-names></name>
<name><surname>Trautwein</surname> <given-names>NF</given-names></name>
<name><surname>Brosch-Lenz</surname> <given-names>J</given-names></name>
<name><surname>Von Beschwitz</surname> <given-names>S</given-names></name>
<name><surname>Kupferschl&#xe4;ger</surname> <given-names>J</given-names></name>
<etal/>
</person-group>. 
<article-title>Optimization of Y-90 radioembolization imaging for post-treatment dosimetry on a long axial field-of-view PET/CT scanner</article-title>. <source>Diagn (Basel)</source>. (<year>2023</year>) <volume>13</volume>. doi:&#xa0;<pub-id pub-id-type="doi">10.3390/diagnostics13223418</pub-id>, PMID: <pub-id pub-id-type="pmid">37998554</pub-id>
</mixed-citation>
</ref>
<ref id="B69">
<label>69</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Zeimpekis</surname> <given-names>KG</given-names></name>
<name><surname>Sari</surname> <given-names>H</given-names></name>
<name><surname>G&#xf6;zl&#xfc;g&#xf6;l</surname> <given-names>N</given-names></name>
<name><surname>Achangwa</surname> <given-names>NR</given-names></name>
<name><surname>Shi</surname> <given-names>K</given-names></name>
<name><surname>Schindewolf</surname> <given-names>M</given-names></name>
<etal/>
</person-group>. 
<article-title>Evaluation of long axial field-of-view (LAFOV) PET/CT for post-treatment dosimetry in Yttrium-90 radioembolization of liver tumors: a comparative study with conventional SPECT imaging</article-title>. <source>Eur J Nucl Med Mol Imaging</source>. (<year>2025</year>) <volume>52</volume>:<page-range>1460&#x2013;71</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1007/s00259-024-07034-9</pub-id>, PMID: <pub-id pub-id-type="pmid">39730786</pub-id>
</mixed-citation>
</ref>
<ref id="B70">
<label>70</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Basha</surname> <given-names>MAA</given-names></name>
<name><surname>AlAzzazy</surname> <given-names>MZ</given-names></name>
<name><surname>Ahmed</surname> <given-names>AF</given-names></name>
<name><surname>Yousef</surname> <given-names>HY</given-names></name>
<name><surname>Shehata</surname> <given-names>SM</given-names></name>
<name><surname>El Sammak</surname> <given-names>D</given-names></name>
<etal/>
</person-group>. 
<article-title>Does a combined CT and MRI protocol enhance the diagnostic efficacy of LI-RADS in the categorization of hepatic observations? A prospective comparative study</article-title>. <source>Eur Radiol</source>. (<year>2018</year>) <volume>28</volume>:<page-range>2592&#x2013;603</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1007/s00330-017-5232-y</pub-id>, PMID: <pub-id pub-id-type="pmid">29368164</pub-id>
</mixed-citation>
</ref>
<ref id="B71">
<label>71</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Joo</surname> <given-names>I</given-names></name>
<name><surname>Kim</surname> <given-names>SY</given-names></name>
<name><surname>Kang</surname> <given-names>TW</given-names></name>
<name><surname>Kim</surname> <given-names>YK</given-names></name>
<name><surname>Park</surname> <given-names>BJ</given-names></name>
<name><surname>Lee</surname> <given-names>YJ</given-names></name>
<etal/>
</person-group>. 
<article-title>Radiologic-Pathologic Correlation of Hepatobiliary Phase Hypointense Nodules without Arterial Phase Hyperenhancement at Gadoxetic Acid-enhanced MRI: A Multicenter Study</article-title>. <source>Radiology</source>. (<year>2020</year>) <volume>296</volume>:<page-range>335&#x2013;45</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1148/radiol.2020192275</pub-id>, PMID: <pub-id pub-id-type="pmid">32484414</pub-id>
</mixed-citation>
</ref>
<ref id="B72">
<label>72</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Rodr&#xed;guez-Fraile</surname> <given-names>M</given-names></name>
<name><surname>Ezponda</surname> <given-names>A</given-names></name>
<name><surname>Grisanti</surname> <given-names>F</given-names></name>
<name><surname>Mor&#xe1;n</surname> <given-names>V</given-names></name>
<name><surname>Calvo</surname> <given-names>M</given-names></name>
<name><surname>Beri&#xe1;n</surname> <given-names>P</given-names></name>
<etal/>
</person-group>. 
<article-title>The joint use of (99m)Tc-MAA-SPECT/CT and cone-beam CT optimizes radioembolization planning</article-title>. <source>EJNMMI Res</source>. (<year>2021</year>) <volume>11</volume>:<fpage>23</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1186/s13550-021-00764-z</pub-id>, PMID: <pub-id pub-id-type="pmid">33661428</pub-id>
</mixed-citation>
</ref>
<ref id="B73">
<label>73</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Kim</surname> <given-names>EH</given-names></name>
<name><surname>Oh</surname> <given-names>JS</given-names></name>
<name><surname>Chun</surname> <given-names>HJ</given-names></name>
<name><surname>Choi</surname> <given-names>BG</given-names></name>
<name><surname>Lee</surname> <given-names>HG</given-names></name>
</person-group>. 
<article-title>Usefulness of fusion images of unenhanced and contrast-enhanced arterial phase cone-beam CT in the detection of viable hepatocellular carcinoma during transarterial chemoembolization</article-title>. <source>Diagn Interv Radiol</source>. (<year>2018</year>) <volume>24</volume>:<page-range>262&#x2013;7</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.5152/dir.2018.17503</pub-id>, PMID: <pub-id pub-id-type="pmid">30211679</pub-id>
</mixed-citation>
</ref>
<ref id="B74">
<label>74</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Kokabi</surname> <given-names>N</given-names></name>
<name><surname>Arndt-Webster</surname> <given-names>L</given-names></name>
<name><surname>Chen</surname> <given-names>B</given-names></name>
<name><surname>Brandon</surname> <given-names>D</given-names></name>
<name><surname>Sethi</surname> <given-names>I</given-names></name>
<name><surname>Davarpanahfakhr</surname> <given-names>A</given-names></name>
<etal/>
</person-group>. 
<article-title>Voxel-based dosimetry predicting treatment response and related toxicity in HCC patients treated with resin-based Y90 radioembolization: a prospective, single-arm study</article-title>. <source>Eur J Nucl Med Mol Imaging</source>. (<year>2023</year>) <volume>50</volume>:<page-range>1743&#x2013;52</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1007/s00259-023-06111-9</pub-id>, PMID: <pub-id pub-id-type="pmid">36650357</pub-id>
</mixed-citation>
</ref>
<ref id="B75">
<label>75</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Fowler</surname> <given-names>KJ</given-names></name>
<name><surname>Maughan</surname> <given-names>NM</given-names></name>
<name><surname>Laforest</surname> <given-names>R</given-names></name>
<name><surname>Saad</surname> <given-names>NE</given-names></name>
<name><surname>Sharma</surname> <given-names>A</given-names></name>
<name><surname>Olsen</surname> <given-names>J</given-names></name>
<etal/>
</person-group>. 
<article-title>PET/MRI of hepatic 90Y microsphere deposition determines individual tumor response</article-title>. <source>Cardiovasc Intervent Radiol</source>. (<year>2016</year>) <volume>39</volume>:<page-range>855&#x2013;64</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1007/s00270-015-1285-y</pub-id>, PMID: <pub-id pub-id-type="pmid">26721589</pub-id>
</mixed-citation>
</ref>
<ref id="B76">
<label>76</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Rhee</surname> <given-names>TK</given-names></name>
<name><surname>Naik</surname> <given-names>NK</given-names></name>
<name><surname>Deng</surname> <given-names>J</given-names></name>
<name><surname>Atassi</surname> <given-names>B</given-names></name>
<name><surname>Mulcahy</surname> <given-names>MF</given-names></name>
<name><surname>Kulik</surname> <given-names>LM</given-names></name>
<etal/>
</person-group>. 
<article-title>Tumor response after yttrium-90 radioembolization for hepatocellular carcinoma: comparison of diffusion-weighted functional MR imaging with anatomic MR imaging</article-title>. <source>J Vasc Interv Radiol</source>. (<year>2008</year>) <volume>19</volume>:<page-range>1180&#x2013;6</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.jvir.2008.05.002</pub-id>, PMID: <pub-id pub-id-type="pmid">18656011</pub-id>
</mixed-citation>
</ref>
<ref id="B77">
<label>77</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Levillain</surname> <given-names>H</given-names></name>
<name><surname>Bagni</surname> <given-names>O</given-names></name>
<name><surname>Deroose</surname> <given-names>CM</given-names></name>
<name><surname>Dieudonn&#xe9;</surname> <given-names>A</given-names></name>
<name><surname>Gnesin</surname> <given-names>S</given-names></name>
<name><surname>Grosser</surname> <given-names>OS</given-names></name>
<etal/>
</person-group>. 
<article-title>International recommendations for personalised selective internal radiation therapy of primary and metastatic liver diseases with yttrium-90 resin microspheres</article-title>. <source>Eur J Nucl Med Mol Imaging</source>. (<year>2021</year>) <volume>48</volume>:<page-range>1570&#x2013;84</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1007/s00259-020-05163-5</pub-id>, PMID: <pub-id pub-id-type="pmid">33433699</pub-id>
</mixed-citation>
</ref>
<ref id="B78">
<label>78</label>
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Wu</surname> <given-names>Z</given-names></name>
<name><surname>Ouyang</surname> <given-names>S</given-names></name>
<name><surname>Gao</surname> <given-names>J</given-names></name>
<name><surname>Hu</surname> <given-names>J</given-names></name>
<name><surname>Guo</surname> <given-names>Q</given-names></name>
<name><surname>Liu</surname> <given-names>D</given-names></name>
<etal/>
</person-group>. 
<article-title>Role of radiomics-based multiomics panel in the microenvironment and prognosis of hepatocellular carcinoma</article-title>. <source>Acad Radiol</source>. (<year>2025</year>) <volume>32</volume>:<page-range>1961&#x2013;70</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.acra.2024.12.039</pub-id>, PMID: <pub-id pub-id-type="pmid">39765431</pub-id>
</mixed-citation>
</ref>
</ref-list>
<fn-group>
<fn id="n1" fn-type="custom" custom-type="edited-by">
<p>Edited by: <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/646252">Denise Fabian</ext-link>, University of Kentucky, United States</p></fn>
<fn id="n2" fn-type="custom" custom-type="reviewed-by">
<p>Reviewed by: <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/653403">Han Lv</ext-link>, Capital Medical University, China</p>
<p><ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/2948782">Pragati Rai</ext-link>, Hamad Medical Corporation, Qatar</p></fn>
</fn-group>
<fn-group>
<fn fn-type="abbr" id="abbrev1">
<label>Abbreviations:</label>
<p>HCC, Hepatocellular carcinoma; <sup>90</sup>Y-SIRT, Yttrium-90 selective internal radiation therapy; US, ultrasound; CEUS, contrast-enhanced ultrasound; CECT, contrast-enhanced CT; MDCT, multidetector CT; DECT, dual-energy CT; CTLP, CT liver perfusion; CBCT, cone-beam CT; Angio-CT, angiography CT; <sup>99m</sup>Tc-MAA, <sup>99m</sup>Tc-macroaggregated albumin<bold>;</bold> PET/CT, positron emission tomography/CT; SPECT/CT, single-photon emission computed tomography/CT; CE-MRI, contrast-enhanced MRI; DCE-MRI, dynamic contrast-enhanced MRI; DWI, diffusion-weighted imaging; ADC, apparent diffusion coefficient; DSA, digital subtraction angiography; 3D, three-dimensional; TOF, time-of-flight; LAFOV, long axial field-of-view; DVH, dose&#x2013;volume histogram; <sup>18</sup>F-FDG, <sup>18</sup>F-fluorodeoxyglucose; <sup>18</sup>F-FCH, <sup>18</sup>F-fluorocholine; Gd-EOB-DTPA, gadoxetic acid; OATP, organic anion transporting polypeptides; GRASP, golden-angle radial sparse parallel; TNR, tumor-to-normal liver ratio; D70, minimum dose to 70% of the tumor volume.</p>
</fn>
</fn-group>
</back>
</article>