<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" article-type="brief-report" dtd-version="2.3" xml:lang="EN">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Oncol.</journal-id>
<journal-title>Frontiers in Oncology</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Oncol.</abbrev-journal-title>
<issn pub-type="epub">2234-943X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fonc.2024.1369603</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Oncology</subject>
<subj-group>
<subject>Brief Research Report</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Virtual clinical trial-based study for clinical evaluation of projection-reduced low-dose cone-beam CT for image guided radiotherapy</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" equal-contrib="yes">
<name>
<surname>Wang</surname>
<given-names>Meijiao</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="author-notes" rid="fn003">
<sup>&#x2020;</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
</contrib>
<contrib contrib-type="author" equal-contrib="yes">
<name>
<surname>Yao</surname>
<given-names>Kaining</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="author-notes" rid="fn003">
<sup>&#x2020;</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Zhao</surname>
<given-names>Yixin</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<xref ref-type="author-notes" rid="fn001">
<sup>*</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Geng</surname>
<given-names>Jianhao</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Zhu</surname>
<given-names>Xianggao</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/2261940"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Liu</surname>
<given-names>Zhiyan</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/991132"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Li</surname>
<given-names>Yongheng</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/859415"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Wu</surname>
<given-names>Hao</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Du</surname>
<given-names>Yi</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
<xref ref-type="author-notes" rid="fn001">
<sup>*</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1266736"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
</contrib-group>
<aff id="aff1">
<sup>1</sup>
<institution>Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Department of Radiation Oncology, Peking University Cancer Hospital &amp; Institute</institution>, <addr-line>Beijing</addr-line>, <country>China</country>
</aff>
<aff id="aff2">
<sup>2</sup>
<institution>Department of Otolaryngology, Head and Neck Surgery, Peking University People&#x2019;s Hospital</institution>, <addr-line>Beijing</addr-line>, <country>China</country>
</aff>
<aff id="aff3">
<sup>3</sup>
<institution>Institute of Medical Technology, Peking University Health Science Center</institution>, <addr-line>Beijing</addr-line>, <country>China</country>
</aff>
<author-notes>
<fn fn-type="edited-by">
<p>Edited by: Martin Bues, Mayo Clinic Arizona, United States</p>
</fn>
<fn fn-type="edited-by">
<p>Reviewed by: Christian B&#xe4;umer, West German Proton Therapy Centre Essen (WPE), Germany</p>
<p>Mattison Flakus, Mayo Clinic Arizona, United States</p>
<p>Sara Bashir, Mayo Clinic Arizona, United States, in collaboration with reviewer MF</p>
</fn>
<fn fn-type="corresp" id="fn001">
<p>*Correspondence: Yixin Zhao, <email xlink:href="mailto:zhaoyixin16@163.com">zhaoyixin16@163.com</email>; Yi Du, <email xlink:href="mailto:yi.du@hotmail.com">yi.du@hotmail.com</email>
</p>
</fn>
<fn fn-type="equal" id="fn003">
<p>&#x2020;These authors have contributed equally to this work</p>
</fn>
</author-notes>
<pub-date pub-type="epub">
<day>05</day>
<month>07</month>
<year>2024</year>
</pub-date>
<pub-date pub-type="collection">
<year>2024</year>
</pub-date>
<volume>14</volume>
<elocation-id>1369603</elocation-id>
<history>
<date date-type="received">
<day>12</day>
<month>01</month>
<year>2024</year>
</date>
<date date-type="accepted">
<day>12</day>
<month>06</month>
<year>2024</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2024 Wang, Yao, Zhao, Geng, Zhu, Liu, Li, Wu and Du</copyright-statement>
<copyright-year>2024</copyright-year>
<copyright-holder>Wang, Yao, Zhao, Geng, Zhu, Liu, Li, Wu and Du</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<sec>
<title>Purpose</title>
<p>Repeated cone-beam CT (CBCT) scans for image-guided radiotherapy (IGRT) increase the health risk of radiation-induced malignancies. Patient-enrolled studies to optimize scan protocols are inadequate. We proposed a virtual clinical trial-based approach to evaluate projection-reduced low-dose CBCT for IGRT.</p>
</sec>
<sec>
<title>Materials and methods</title>
<p>A total of 71 patients were virtually enrolled with 26 head, 23 thorax and 22 pelvis scans. Projection numbers of full-dose CBCT scans were reduced to 1/2, 1/4, and 1/8 of the original to simulate low-dose scans. Contrast-to-noise ratio (CNR) values in fat and muscle were measured in the full-dose and low-dose images. CBCT images were registered to planning CT to derive 6-degree-of-freedom couch shifts. Registration errors were statistically analyzed with the Wilcoxon paired signed-rank test.</p>
</sec>
<sec>
<title>Results</title>
<p>As projection numbers were reduced, CNR values descended and the magnitude of registration errors increased. The mean CNR values of full-dose and half-dose CBCT were &gt;3.0. For full-dose and low-dose CBCT (i.e. 1/2, 1/4 and 1/8 full-dose), the mean registration errors were&lt; &#xb1; 0.4 mm in translational directions (LAT, LNG, VRT) and &#xb1;0.2 degree in rotational directions (Pitch, Roll, Yaw); the mean magnitude of registration errors were&lt; 1 mm in translation and&lt; 0.5 degree in rotation. The couch shift differences between full-dose and low-dose CBCT were not statistically significant (p&gt;0.05) in all the directions.</p>
</sec>
<sec>
<title>Conclusion</title>
<p>The results indicate that while the impact of dose-reduction on CBCT couch shifts is not significant, the impact on CNR values is significant. Further validation on optimizing CBCT imaging dose is required.</p>
</sec>
</abstract>
<kwd-group>
<kwd>CBCT</kwd>
<kwd>low dose</kwd>
<kwd>image guided radiotherapy</kwd>
<kwd>virtual clinical trial</kwd>
<kwd>imaging dose</kwd>
</kwd-group>
<contract-num rid="cn001">12375335, 12005007</contract-num>
<contract-num rid="cn002">2019YFF01014405</contract-num>
<contract-sponsor id="cn001">National Natural Science Foundation of China<named-content content-type="fundref-id">10.13039/501100001809</named-content>
</contract-sponsor>
<contract-sponsor id="cn002">National Key Research and Development Program of China<named-content content-type="fundref-id">10.13039/501100012166</named-content>
</contract-sponsor>
<counts>
<fig-count count="3"/>
<table-count count="2"/>
<equation-count count="3"/>
<ref-count count="26"/>
<page-count count="8"/>
<word-count count="3408"/>
</counts>
<custom-meta-wrap>
<custom-meta>
<meta-name>section-in-acceptance</meta-name>
<meta-value>Radiation Oncology</meta-value>
</custom-meta>
</custom-meta-wrap>
</article-meta>
</front>
<body>
<sec id="s1" sec-type="intro">
<label>1</label>
<title>Introduction</title>
<p>On-board cone-beam computed tomography (CBCT) plays a considerable role in modern radiotherapy, as it is able to provide three-dimensional anatomy images with high-resolution. The use of CBCT facilitates patient positioning verification and target localization by anatomy alignment with reference to planning CT images, therefore substantially improving the accuracy, safety and effectiveness of image-guided radiotherapy (IGRT) (<xref ref-type="bibr" rid="B1">1</xref>&#x2013;<xref ref-type="bibr" rid="B3">3</xref>). Despite the numerous advantages, CBCT comes at increased x-ray exposure compared with 2D radiographic imaging (<xref ref-type="bibr" rid="B4">4</xref>, <xref ref-type="bibr" rid="B5">5</xref>). Since patients mostly receive recurrent CBCT scans over the entire treatment course, the health risk of imaging radiation induced by CBCT has raised serious concerns (<xref ref-type="bibr" rid="B6">6</xref>&#x2013;<xref ref-type="bibr" rid="B11">11</xref>). For instance, it was estimated by Zhou et&#xa0;al. (<xref ref-type="bibr" rid="B8">8</xref>) that the average lifetime risk of cancer attributed to cumulative imaging doses per 100,000 individuals was 78 for brain cancer, 271 for lung cancer, and 510 for leukemia. A recent international survey on imaging practices in radiotherapy (<xref ref-type="bibr" rid="B12">12</xref>) shows that most centers used vendor-provided CBCT protocols in routine practice and less than 50% optimize the protocols to some extent. Growing efforts have been made to reduce imaging dose, and several strategies are recommended (<xref ref-type="bibr" rid="B4">4</xref>, <xref ref-type="bibr" rid="B13">13</xref>, <xref ref-type="bibr" rid="B14">14</xref>). A common and clinically available strategy of dose reduction is to reduce x-ray exposure via three techniques. The first technique is to use a short-arc scan over about 200 degrees instead of a 360-degree full-arc scan. The data acquired over short arcs are sufficient to reconstruct images of small objects, and therefore short-arc configuration has become the default for head-and-neck and pediatric protocols. The second is to decrease tube output (mAs) so as to reduce incident x-ray photons per projection, and the third is to increase angular separation to reduce exposure frequency. Several studies demonstrate that reduced exposure leads to CBCT image quality degradation. Wood et&#xa0;al. (<xref ref-type="bibr" rid="B15">15</xref>) evaluated mAs reduction on a pelvis phantom and made size-based recommendation of mAs settings. Yan et&#xa0;al. (<xref ref-type="bibr" rid="B16">16</xref>) investigated the relationship between the image quality and imaging dose and established a mAs-dependent empirical function. Lu et&#xa0;al. (<xref ref-type="bibr" rid="B17">17</xref>) evaluated the effect of reducing projection number on image quality and registration accuracy, concluding the projection-number reduction technique could achieve uncompromised registration accuracy under conscientious care. Similarly, Men et&#xa0;al. (<xref ref-type="bibr" rid="B18">18</xref>) evaluated the image quality, dose and registration errors acquired with different CBCT angular separations, indicating that CBCT images with fewer projections impair image quality and registration accuracy. Olch et&#xa0;al. (<xref ref-type="bibr" rid="B19">19</xref>) compared the image quality and registration accuracy between kV-pair imaging and low-dose CBCT acquired with reduced mAs and projections. The study demonstrates that CBCT dose can be reduced to a level comparable to kV-pair imaging with similar or enhanced patient positioning accuracy.</p>
<p>It is important to note that all the aforementioned studies are all phantom-based without any patient-involved validation. To our knowledge, there were only two relevant clinical study on low-dose CBCT for IGRT. The first study was by Alcorn et&#xa0;al. (<xref ref-type="bibr" rid="B20">20</xref>), which was an international study to evaluate the feasibility of a pre-defined low-dose CBCT protocol in pediatrics that received central neural system radiotherapy. The other study was by Bryce-Atkinson et&#xa0;al. (<xref ref-type="bibr" rid="B21">21</xref>) using CBCT scans from 7 pediatric patients to simulate low-dose scans by either adding noise or halving the number of projections. Due to the limited patient category, imaging site and cohort size, further validation is required. To this end, this study aims to comprehensively evaluate the image quality, image dose, and registration accuracy of CBCT images reconstructed using projections acquired with different combinations of angular range. The key innovation and highlight are: 1) we used a virtual clinical trial-based approach retrospectively enrolling a total of 71 real patients, and 2) we evaluated the clinical viability of low-dose CBCT for head, thorax and pelvis IGRT.</p>
</sec>
<sec id="s2" sec-type="materials|methods">
<label>2</label>
<title>Materials and methods</title>
<sec id="s2_1">
<label>2.1</label>
<title>Patient enrollment and data acquisition</title>
<p>A total of 71 patients treated at our institution (Peking University Cancer Hospital, China) were retrospectively enrolled under the approval of the institutional review board. The patients were all adults (age ranging from 27 to 68) without any metal implant and were treated on either an Edge linac or VitalBeam linac (Varian Medical Systems, Palo Alto, USA) from March 2022 to July 2022. The patients were categorized into three groups according to imaging sites, i.e., 26 head scan patients (10 with brain metastasis, 9 with nasopharyngeal carcinoma and 7 with glioma), 23 thorax scan patients (all with lung cancer) and 22 pelvis scan patients (9 with cervical cancer, 9 with rectal cancer and 4 with liver cancer). For the head scan group, patients were all immobilized with the open-face Double-Shell Positioning System (MacroMedics, Belgium) (<xref ref-type="bibr" rid="B22">22</xref>). For the thorax scan group, 15 patients were immobilized with thermoplastic and the other 8 with vacuum bag cushions. For the pelvis scan group, 4 liver patients were immobilized with ZiFix&#x2122; abdominal compression belt (Qfix, USA).</p>
<p>The pertinent imaging protocols were listed in <xref ref-type="table" rid="T1">
<bold>Table&#xa0;1</bold>
</xref> (<xref ref-type="bibr" rid="B23">23</xref>). For each patient, the raw scan data of the first CBCT scan was off-line retrieved from the linac imaging node. The CBCT imaging dose was defined in weighted CT dose index (CTDIw), and was recalibrated previous to this study with the aid of on-site Varian service team.</p>
<table-wrap id="T1" position="float">
<label>Table&#xa0;1</label>
<caption>
<p>Key parameters of default (full-dose) CBCT protocols.</p>
</caption>
<table frame="hsides">
<thead>
<tr>
<th valign="top" align="left">Protocol</th>
<th valign="top" align="left">kVp</th>
<th valign="top" align="left">Scan Range (deg)</th>
<th valign="top" align="left">Projection Number</th>
<th valign="top" align="left">Exposure (mAs)</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Head</td>
<td valign="top" align="left">100</td>
<td valign="top" align="left">200</td>
<td valign="top" align="left">500</td>
<td valign="top" align="left">150</td>
</tr>
<tr>
<td valign="top" align="left">Thorax</td>
<td valign="top" align="left">125</td>
<td valign="top" align="left">360</td>
<td valign="top" align="left">895</td>
<td valign="top" align="left">270</td>
</tr>
<tr>
<td valign="top" align="left">Pelvis</td>
<td valign="top" align="left">125</td>
<td valign="top" align="left">360</td>
<td valign="top" align="left">895</td>
<td valign="top" align="left">270</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
<sec id="s2_2">
<label>2.2</label>
<title>Generation of projection-reduced low-dose CBCT</title>
<p>For each clinical CBCT scan, three low-dose scans were derived by picking the first projection of every two, four and eight projections to simulate 1/2, 1/4 and 1/8 the clinical sampling rate. This data resampling approach was to simulate a virtual clinical trial, in which a patient was simultaneously scanned at four dose levels, i.e., default (full-dose), 1/2, 1/4, and 1/8 the full dose levels. Therefore, the scan series were referred to as <italic>S<sub>1</sub>
</italic>, <italic>S<sub>1/2</sub>
</italic>, <italic>S<sub>1/4</sub>
</italic>, and <italic>S<sub>1/8</sub>
</italic>, respectively.</p>
<p>All the scan data were preprocessed and reconstructed in MATLAB R2022b (Mathworks, USA) using TIGRE-VarianCBCT, a validated open-source toolkit for on-board CBCT imaging (<xref ref-type="bibr" rid="B24">24</xref>). The reconstruction algorithm was FDK (Feldkamp, Davis and Kress), which is identical to the algorithm used in the current state of clinical practice.</p>
</sec>
<sec id="s2_3">
<label>2.3</label>
<title>Impact evaluation</title>
<sec id="s2_3_1">
<label>2.3.1</label>
<title>Soft tissue contrast</title>
<p>The soft tissue contrast was a key aspect to reflect image quality. Herein, we adopted the muscle and fat contrast-to-noise (CNR) proposed by Bryce-Atkinson et&#xa0;al. (<xref ref-type="bibr" rid="B21">21</xref>) to define the soft-tissue contrast in <xref ref-type="disp-formula" rid="eq1">Equation 1</xref> as</p>
<disp-formula id="eq1">
<label>(1)</label>
<mml:math display="block" id="M1">
<mml:mrow>
<mml:mtext>CNR</mml:mtext>
<mml:mo>=</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mrow>
<mml:mo>|</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mtext>M</mml:mtext>
<mml:mrow>
<mml:mtext>muscle</mml:mtext>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:msub>
<mml:mtext>M</mml:mtext>
<mml:mrow>
<mml:mtext>fat</mml:mtext>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mo>|</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mrow>
<mml:msqrt>
<mml:mrow>
<mml:msubsup>
<mml:mtext>&#x3c3;</mml:mtext>
<mml:mrow>
<mml:mtext>muscle</mml:mtext>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msubsup>
<mml:mo>+</mml:mo>
<mml:msubsup>
<mml:mtext>&#x3c3;</mml:mtext>
<mml:mrow>
<mml:mtext>fat</mml:mtext>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msubsup>
</mml:mrow>
</mml:msqrt>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:math>
</disp-formula>
<p>where M and &#x3c3; were the mean HU value and standard deviation over the selected region-of-interest (ROI). In this study, the soft tissue contrast performance was defined as acceptable if the CNR exceeded 3 as per the Rose criterion (<xref ref-type="bibr" rid="B25">25</xref>), in line with the study by Bryce-Atkinson et&#xa0;al. (<xref ref-type="bibr" rid="B21">21</xref>).</p>
<p>For the head scan patients, the ROI was defined at the nasopharynx level: lateral pterygoid was selected as the muscle region, and the subcutaneous fat was fat region, as shown in <xref ref-type="fig" rid="f2">
<bold>Figure&#xa0;2A</bold>
</xref>. For the thorax and pelvis scan patients, subcutaneous fat and muscle regions were selected as shown in <xref ref-type="fig" rid="f2">
<bold>Figures&#xa0;2B, C</bold>
</xref>.</p>
</sec>
<sec id="s2_3_2">
<label>2.3.2</label>
<title>Relative registration errors</title>
<p>The CBCT images of different dose levels were rigidly registered to planning CT to acquire couch shifts. The registration was performed in 3D Slicer (version 5.2.1) (<xref ref-type="bibr" rid="B26">26</xref>), open source software application for medical image analysis. While 3D Slicer was not intended for clinical use, the key reason we used it was that the registration algorithm (mutual information based rigid registration) in 3D Slicer was identical with the clinical system. The CBCT-to-CT registration was rigid and in 6-degree-of-freedom (6DoF), i.e., three translational directions (VRT, LAT and LNG) and three rotational directions (Yaw, Pitch and Roll). The registration result of the full-dose level (S<sub>1</sub>) was used as gold standard benchmark, and registration accuracy between the low-dose CBCT scans and the respective benchmark were compared to derive relative registration errors in each direction. The magnitude of the relative registration errors were calculated in <xref ref-type="disp-formula" rid="eq2">Equations 2</xref>, <xref ref-type="disp-formula" rid="eq3">3</xref> as</p>
<disp-formula id="eq2">
<label>(2)</label>
<mml:math display="block" id="M2">
<mml:mrow>
<mml:mtext>Tx</mml:mtext>
<mml:mo>=</mml:mo>
<mml:msqrt>
<mml:mrow>
<mml:msubsup>
<mml:mtext>&#x3b5;</mml:mtext>
<mml:mrow>
<mml:mtext>VRT</mml:mtext>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msubsup>
<mml:mo>+</mml:mo>
<mml:msubsup>
<mml:mtext>&#x3b5;</mml:mtext>
<mml:mrow>
<mml:mtext>LAT</mml:mtext>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msubsup>
<mml:mo>+</mml:mo>
<mml:msubsup>
<mml:mtext>&#x3b5;</mml:mtext>
<mml:mrow>
<mml:mtext>LNG</mml:mtext>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msubsup>
</mml:mrow>
</mml:msqrt>
</mml:mrow>
</mml:math>
</disp-formula>
<disp-formula id="eq3">
<label>(3)</label>
<mml:math display="block" id="M3">
<mml:mrow>
<mml:mtext>Rx</mml:mtext>
<mml:mo>=</mml:mo>
<mml:msqrt>
<mml:mrow>
<mml:msubsup>
<mml:mtext>&#x3b5;</mml:mtext>
<mml:mrow>
<mml:mtext>Yaw</mml:mtext>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msubsup>
<mml:mo>+</mml:mo>
<mml:msubsup>
<mml:mtext>&#x3b5;</mml:mtext>
<mml:mrow>
<mml:mtext>Pitch</mml:mtext>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msubsup>
<mml:mo>+</mml:mo>
<mml:msubsup>
<mml:mtext>&#x3b5;</mml:mtext>
<mml:mrow>
<mml:mtext>Roll</mml:mtext>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msubsup>
</mml:mrow>
</mml:msqrt>
</mml:mrow>
</mml:math>
</disp-formula>
<p>where &#x3b5; was the relative registration error, and Tx and Rx were the magnitudes of translational and rotational relative errors respectively.</p>
</sec>
<sec id="s2_3_3">
<label>2.3.3</label>
<title>Statistical analysis</title>
<p>The mean, standard deviation, 25&#x2013;75% percentile (Q1-Q3), minimum and maximum values over the CNR results and relative registration errors were calculated. In addition, the 6DoF couch shifts acquired by registration to planning-CT via different CBCT image series were compared. The couch shifts of S<sub>1/2</sub>, S<sub>1/4</sub> and S<sub>1/8</sub> were paired with the full-dose method in each direction and then tested with the Wilcoxon paired signed-rank test. In this study, data analysis was performed in OriginPro (version 2021a, OriginLab, USA), and p-value&lt; 0.05 was considered statistically significant.</p>
</sec>
</sec>
</sec>
<sec id="s3" sec-type="results">
<label>3</label>
<title>Results</title>
<p>
<xref ref-type="fig" rid="f1">
<bold>Figure&#xa0;1</bold>
</xref> shows representative reconstructed images of real patients that received head (a-row), thorax (b-row) and pelvis (c-row) scans respectively with the default (<italic>S<sub>1</sub>
</italic>) and projection-reduced protocols (<italic>S<sub>1/2</sub>, S<sub>1/4</sub>, S<sub>1/8</sub>
</italic>). As we reduced the projection number, image quality deteriorated as the dose was lowered. Compared with the full-dose reference images (left-column in <xref ref-type="fig" rid="f1">
<bold>Figure&#xa0;1</bold>
</xref>), image noise and strike artifacts in dose-reduced protocols became obvious, which were induced by increased angular separations. While image details were blurred, the loss of soft-tissue contrast was relatively greater than that of bony structures.</p>
<fig id="f1" position="float">
<label>Figure&#xa0;1</label>
<caption>
<p>Visual image quality comparison of head (<bold>A</bold>-row), thorax (<bold>B</bold>-row), and pelvis (<bold>C</bold>-row) CBCT. The 1<sup>st</sup> column shows full-dose images, and 2<sup>nd</sup>, 3<sup>rd</sup> and 4<sup>th</sup> columns show <italic>S<sub>1/2</sub>
</italic>, <italic>S<sub>1/4</sub>
</italic>, and <italic>S<sub>1/8</sub>
</italic> images. The red and yellow annotations represent subcutaneous fat and muscle regions for CNR calculation.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fonc-14-1369603-g001.tif"/>
</fig>
<p>The 6DoF registration errors of projection-reduced head, thorax, and pelvis scans relative to the full-dose scans are summarized in <xref ref-type="fig" rid="f2">
<bold>Figure&#xa0;2</bold>
</xref>, showing the median, mean &#xb1; standard deviation (SD) and 25&#x2013;75% interpercentile range (Q1-Q3). We can clearly see that, regardless of imaging site or scan protocol, the mean and median values of relative errors across six directions were quite close to zero, ranging within &#xb1;0.4 mm in translation and within &#xb1;0.2 degrees in rotation. We use Q1-Q3 and mean &#xb1; SD to indicate uncertainties in relative errors. For translational directions, the Q1-Q3 values across all protocols ranged within &#xb1;0.5 mm in translation except that in LNG for pelvis scan protocols (&#xb1; 0.7 mm), and a similar trend was identified for mean &#xb1; SD. For rotational directions, the uncertainties in head protocols were relatively larger than in those in thorax and pelvis protocols. This may be attributed to the uncertainties induced by cervical/neck flexion. In addition, the couch shifts of <italic>S<sub>1/2</sub>, S<sub>1/4</sub>
</italic> and <italic>S<sub>1/8</sub>
</italic> were paired with those of <italic>S<sub>1</sub>
</italic> in each direction to perform Wilcoxon paired signed-rank test. The p-values across all the tests were &gt; 0.05, among which the smallest value was about 0.17, indicating the couch shift differences between projection-reduced protocols and the full-dose protocol were not statistically significant.</p>
<fig id="f2" position="float">
<label>Figure&#xa0;2</label>
<caption>
<p>Relative registration error distributions between projection-reduced CBCT and full-dose CBCT in 6DoF: head scan translational shifts <bold>(A)</bold> and rotational shifts <bold>(B)</bold>; thorax scan translational shifts <bold>(C)</bold> and rotational shifts <bold>(D)</bold>; pelvis scan translational shifts <bold>(E)</bold> and rotational shifts <bold>(F)</bold>.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fonc-14-1369603-g002.tif"/>
</fig>
<p>The CNR, Tx and Rx values over the testing patients were summarized in <xref ref-type="table" rid="T2">
<bold>Table&#xa0;2</bold>
</xref> and <xref ref-type="fig" rid="f3">
<bold>Figure&#xa0;3</bold>
</xref>. As the projection numbers were reduced, the imaging dose decreased, leading to significant descending in CNR performance and ascending in Tx and Rx values. For CNR, while the <italic>S<sub>1/2</sub>
</italic> protocol exhibited inferior performance to the full-dose protocol, the mean values across the three sites were &gt;3.0, indicating the soft-tissue contrast performance was generally acceptable even when the projection number was halved from the default setting. For Tx, the mean values were mostly less than 1 mm except for <italic>S<sub>1/8</sub>
</italic> protocol in pelvis scan. This is similar to the trend in <xref ref-type="fig" rid="f2">
<bold>Figure&#xa0;2E</bold>
</xref>, where <italic>S<sub>1/8</sub>
</italic> exhibited the largest uncertainties. For Rx, while the mean values for head scans were between 0.4 and 0.5 degree, those for thorax and pelvis scans were all less than 0.4 degree.</p>
<fig id="f3" position="float">
<label>Figure&#xa0;3</label>
<caption>
<p>CNR distributions of full-dose CBCT scans and low-dose CBCT scans (<italic>S<sub>1/2</sub>
</italic>, <italic>S<sub>1/4</sub>
</italic>, and <italic>S<sub>1/8</sub>
</italic>) in sites of <bold>(A)</bold> head, <bold>(B)</bold> thorax and <bold>(C)</bold> pelvis.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fonc-14-1369603-g003.tif"/>
</fig>
<table-wrap id="T2" position="float">
<label>Table&#xa0;2</label>
<caption>
<p>Performance comparison of CNR, Tx and Rx across different protocols.</p>
</caption>
<table frame="hsides">
<thead>
<tr>
<th valign="middle" align="left"/>
<th valign="middle" align="left">Projection No</th>
<th valign="middle" align="left">Dose (mGy)</th>
<th valign="middle" align="left">CNR</th>
<th valign="middle" align="left">Tx (mm)</th>
<th valign="middle" align="left">Rx (degree)</th>
</tr>
</thead>
<tbody>
<tr>
<th valign="middle" colspan="6" align="left">Head</th>
</tr>
<tr>
<td valign="middle" align="right">
<italic>Full-dose</italic>
</td>
<td valign="middle" align="left">500</td>
<td valign="middle" align="left">3.170</td>
<td valign="middle" align="left">
<bold>5.381 &#xb1; 1.287 (3.407&#x2013;7.423)</bold>
</td>
<td valign="middle" align="left">\</td>
<td valign="middle" align="left">\</td>
</tr>
<tr>
<td valign="middle" align="right">
<italic>S<sub>1/2</sub>
</italic>
</td>
<td valign="middle" align="left">250</td>
<td valign="middle" align="left">1.585</td>
<td valign="middle" align="left">
<bold>4.327 &#xb1; 0.720 (3.173&#x2013;5.363)</bold>
</td>
<td valign="middle" align="left">0.298 &#xb1; 0.208 (0.060 - 0.686)</td>
<td valign="middle" align="left">0.421 &#xb1; 0.309 (0.124 - 1.131)</td>
</tr>
<tr>
<td valign="middle" align="right">
<italic>S<sub>1/4</sub>
</italic>
</td>
<td valign="middle" align="left">125</td>
<td valign="middle" align="left">0.793</td>
<td valign="middle" align="left">2.706 &#xb1; 0.218 (2.420&#x2013;3.099)</td>
<td valign="middle" align="left">0.315 &#xb1; 0.193 (0.058 - 0.643)</td>
<td valign="middle" align="left">0.474 &#xb1; 0.396 (0.079 - 1.363)</td>
</tr>
<tr>
<td valign="middle" align="right">
<italic>S<sub>1/8</sub>
</italic>
</td>
<td valign="middle" align="left">63</td>
<td valign="middle" align="left">0.399</td>
<td valign="middle" align="left">1.459 &#xb1; 0.265 (1.030&#x2013;1.877)</td>
<td valign="middle" align="left">0.381 &#xb1; 0.197 (0.155 - 0.709)</td>
<td valign="middle" align="left">0.477 &#xb1; 0.417 (0.057 - 1.266)</td>
</tr>
<tr>
<th valign="middle" colspan="6" align="left">Thorax</th>
</tr>
<tr>
<td valign="middle" align="right">
<italic>Full-dose</italic>
</td>
<td valign="middle" align="left">895</td>
<td valign="middle" align="left">3.970</td>
<td valign="middle" align="left">
<bold>3.730 &#xb1; 0.704 (2.926&#x2013;5.260)</bold>
</td>
<td valign="middle" align="left">\</td>
<td valign="middle" align="left">\</td>
</tr>
<tr>
<td valign="middle" align="right">
<italic>S<sub>1/2</sub>
</italic>
</td>
<td valign="middle" align="left">448</td>
<td valign="middle" align="left">1.987</td>
<td valign="middle" align="left">
<bold>3.052 &#xb1; 0.501 (2.464&#x2013;4.083)</bold>
</td>
<td valign="middle" align="left">0.365 &#xb1; 0.314 (0.088 - 1.544)</td>
<td valign="middle" align="left">0.148 &#xb1; 0.076 (0.010 - 0.278)</td>
</tr>
<tr>
<td valign="middle" align="right">
<italic>S<sub>1/4</sub>
</italic>
</td>
<td valign="middle" align="left">224</td>
<td valign="middle" align="left">0.994</td>
<td valign="middle" align="left">2.268 &#xb1; 0.317 (1.925&#x2013;2.870)</td>
<td valign="middle" align="left">0.360 &#xb1; 0.383 (0.042 - 1.870)</td>
<td valign="middle" align="left">0.176 &#xb1; 0.080 (0.077 - 0.466)</td>
</tr>
<tr>
<td valign="middle" align="right">
<italic>S<sub>1/8</sub>
</italic>
</td>
<td valign="middle" align="left">112</td>
<td valign="middle" align="left">0.497</td>
<td valign="middle" align="left">1.423 &#xb1; 0.262 (1.146&#x2013;1.974)</td>
<td valign="middle" align="left">0.518 &#xb1; 0.339 (0.069 - 1.639)</td>
<td valign="middle" align="left">0.248 &#xb1; 0.107 (0.114 - 0.536)</td>
</tr>
<tr>
<th valign="middle" colspan="6" align="left">Pelvis</th>
</tr>
<tr>
<td valign="middle" align="right">
<italic>Full-dose</italic>
</td>
<td valign="middle" align="left">895</td>
<td valign="middle" align="left">3.970</td>
<td valign="middle" align="left">
<bold>4.226 &#xb1; 1.477 (2.457&#x2013;6.648)</bold>
</td>
<td valign="middle" align="left">\</td>
<td valign="middle" align="left">\</td>
</tr>
<tr>
<td valign="middle" align="right">
<italic>S<sub>1/2</sub>
</italic>
</td>
<td valign="middle" align="left">448</td>
<td valign="middle" align="left">1.987</td>
<td valign="middle" align="left">
<bold>3.647 &#xb1; 1.144 (2.401&#x2013;5.557)</bold>
</td>
<td valign="middle" align="left">0.648 &#xb1; 0.292 (0.241 - 1.283)</td>
<td valign="middle" align="left">0.199 &#xb1; 0.071 (0.082 - 0.283)</td>
</tr>
<tr>
<td valign="middle" align="right">
<italic>S<sub>1/4</sub>
</italic>
</td>
<td valign="middle" align="left">224</td>
<td valign="middle" align="left">0.994</td>
<td valign="middle" align="left">2.846 &#xb1; 0.789 (1.905&#x2013;3.922)</td>
<td valign="middle" align="left">0.751 &#xb1; 0.431 (0.167 - 1.984)</td>
<td valign="middle" align="left">0.218 &#xb1; 0.119 (0.037 - 0.476)</td>
</tr>
<tr>
<td valign="middle" align="right">
<italic>S<sub>1/8</sub>
</italic>
</td>
<td valign="middle" align="left">112</td>
<td valign="middle" align="left">0.497</td>
<td valign="middle" align="left">1.950 &#xb1; 0.487 (1.258&#x2013;2.777)</td>
<td valign="middle" align="left">1.084 &#xb1; 0.752 (0.382 - 2.789)</td>
<td valign="middle" align="left">0.341 &#xb1; 0.165 (0.086 - 0.657)</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn>
<p>1) CNR, Tx, and Rx values were expressed in mean &#xb1; SD (minimum - maximum); 2) bold numeric to indicate mean CNR values &gt; 3.0.</p>
</fn>
</table-wrap-foot>
</table-wrap>
</sec>
<sec id="s4" sec-type="discussion">
<label>4</label>
<title>Discussion</title>
<p>Reducing imaging dose of CBCT has been a prominent concern due to the potential health risks associated with recurrent CBCT scans over the entire treatment course. A direct strategy to reducing dose is to obtain projections as few as feasible through expanding the angular gap in sampling, but with the challenge of ensuring that image quality and registration accuracy are not compromised. In&#xa0;the meantime, how to effectively evaluate the impact of projection reduction on image quality and registration accuracy in the clinical context without impairing treatment accuracy is a challenging issue as well.</p>
<p>Our study proposed a virtual clinical trial-based strategy to perform comprehensive clinical evaluation of projection-reduced low-dose CBCT for IGRT application. In this work, we enrolled a total of 71 real-world patients to quantitatively evaluate image quality and registration accuracy for head, thorax and pelvis CBCT scans. Hence, this virtual clinical trial-based study is more accurate in reflecting the clinical context than previous studies that are either highly controlled (<xref ref-type="bibr" rid="B20">20</xref>, <xref ref-type="bibr" rid="B21">21</xref>) or phantom-based (<xref ref-type="bibr" rid="B15">15</xref>&#x2013;<xref ref-type="bibr" rid="B19">19</xref>). In the meantime, we used the validated open-source research toolkit for image reconstruction (TIGRE-VarianCBCT) and registration (3D Slicer), justifying the reproducibility of all the results. In this context, our analysis yielded important insights.</p>
<p>Firstly, while the reduction of projection numbers led to increased image noise and strike artifacts, acceptable clinical image quality was maintained up to a decrease by half from the default projection number. This was justified by the CNR results in <xref ref-type="table" rid="T2">
<bold>Table&#xa0;2</bold>
</xref>, demonstrating the potential to reduce the imaging dose without significant loss in image quality. However, as the projection number further decreased to 1/4 and 1/8 of the full dose, the CNR values fell below the acceptable threshold, implying substantial deterioration in soft-tissue contrast. This also indicates a limitation in the extent of projection-reduced low-dose CBCT while preserving adequate imaging quality.</p>
<p>Secondly, our study showed that the relative registration errors of projection-reduced CBCT scans compared to full-dose scans were negligible across six directions with mean error&lt; 0.5 mm in translation and&lt;0.4 degree in rotation. Moreover, the error magnitude was&lt; 1.0 mm in translation (Tx) and&lt; 0.4 degree in rotation (Rx). This further demonstrates that a reduction in projection numbers does not necessarily impair the registration accuracy and suggest the maintenance of registration accuracy even at reduced doses, the key concern in IGRT. This finding is in line with those in phantom-based studies by Men et&#xa0;al. (<xref ref-type="bibr" rid="B18">18</xref>) and Olch et&#xa0;al. (<xref ref-type="bibr" rid="B19">19</xref>). Also, as the projection number was further reduced, slight increase in uncertainties were observed, especially in the LNG direction in both thorax pelvis scans. This phenomenon we assume can be attributed to subtle pelvic anatomy changes along the LNG direction.</p>
<p>Moreover, it is worth noting that no statistically significant shift differences were identified between the dose-reduced protocols and the full-dose reference. The consistency of our findings with the literature (<xref ref-type="bibr" rid="B19">19</xref>, <xref ref-type="bibr" rid="B21">21</xref>) reinforces the reliability and potential clinical viability of the projection-reduction strategy.</p>
<p>Our study has several limitations. First, we used auto-matching in CBCT-to-CT registration to minimize any personal bias. However, in clinical practice, therapists or physicists are probably to perform couch shifts with manual corrections. There may be some discrepancy here between the research world and how the shifts would look in a true clinical setting. Second, while the strategy of virtual clinical trial facilitated patient enrollment [for instance, only 6 patients were enrolled in the study by Bryce-Atkinson et&#xa0;al (<xref ref-type="bibr" rid="B21">21</xref>)], due to the limitation of the IRB approval, we only enrolled adult patients. It is well known that age is a key factor attributable to estimating patients&#x2019; risks (<xref ref-type="bibr" rid="B13">13</xref>), as it is pediatric patients that will benefit the most from imaging dose reduction. While we believe some findings in this study are also applicable to pediatric patients, further efforts including more extensive clinical trials are required for solid validation. Thirdly, while we used a virtual clinical trial design to ensure clinical applicability, further prospective clinical trials are needed for a more robust and comprehensive validation, especially in combination with other low-dose techniques. Besides, the retrospective study design, scan sites and the dose-reduction method are also limitations.</p>
</sec>
<sec id="s5" sec-type="conclusions">
<label>5</label>
<title>Conclusion</title>
<p>Our study indicates that while the impact of dose-reduction on CBCT couch shifts is not significant, the impact on CNR values is significant. Further validation on optimizing CBCT imaging dose is required.</p>
</sec>
<sec id="s6" sec-type="data-availability">
<title>Data availability statement</title>
<p>The original contributions presented in the study are included in the article, further inquiries can be directed to the corresponding authors.</p>
</sec>
<sec id="s7" sec-type="ethics-statement">
<title>Ethics statement</title>
<p>The studies involving humans were approved by Peking University Cancer Hospital. The studies were conducted in accordance with the local legislation and institutional requirements. Written informed consent for participation was not required from the participants or the participants&#x2019; legal guardians/next of kin in accordance with the national legislation and institutional requirements.</p>
</sec>
<sec id="s8" sec-type="author-contributions">
<title>Author contributions</title>
<p>MW: Writing &#x2013; original draft. KY: Writing &#x2013; original draft. YZ: Writing &#x2013; review &amp; editing. JG: Writing &#x2013; review &amp; editing. XZ: Writing &#x2013; review &amp; editing. ZL: Writing &#x2013; review &amp; editing. YL:&#xa0;Writing &#x2013; review &amp; editing. HW: Writing &#x2013; review &amp; editing. YD: Writing &#x2013; review &amp; editing.</p>
</sec>
</body>
<back>
<sec id="s9" sec-type="funding-information">
<title>Funding</title>
<p>The author(s) declare financial support was received for the research, authorship, and/or publication of this article. This work was supported in part by National Natural Science Foundation of China (No. 12375335, 12005007), Beijing Natural Science Foundation (No. 1212011), National Key Research and Development Project (No. 2019YFF01014405), Peking University Educational Reform Foundation (No. 2299000138), and Clinical Research Project of Wu Jieping Medical Foundation (No. 320.6750.2022-3-59), Peking University People's Hospital Scientific Research Development Funds (No. RDE2023-09).</p>
</sec>
<sec id="s10" sec-type="COI-statement">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec id="s11" sec-type="disclaimer">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors&#xa0;and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<fn-group>
<title>Abbreviations</title>
<fn fn-type="abbr">
<p>6DoF, 6-degree-of-freedom; CT, computed tomography; CBCT, cone-beam computed tomography; CTDIw, weighted computed tomography dose index; CNR, contrast-to-noise ratio; HU, Hounsfield unit; IGRT, image-guided radiotherapy; IRB, Institutional Review Board; LAT, lateral; LNG, longitudinal; VRT, vertical; Q1, first quartile; Q3, third quartile; SD, standard deviation.</p>
</fn>
</fn-group>
<ref-list>
<title>References</title>
<ref id="B1">
<label>1</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zelefsky</surname> <given-names>MJ</given-names>
</name>
<name>
<surname>Kollmeier</surname> <given-names>M</given-names>
</name>
<name>
<surname>Cox</surname> <given-names>B</given-names>
</name>
<name>
<surname>Fidaleo</surname> <given-names>A</given-names>
</name>
<name>
<surname>Sperling</surname> <given-names>D</given-names>
</name>
<name>
<surname>Pei</surname> <given-names>X</given-names>
</name>
<etal/>
</person-group>. <article-title>Improved clinical outcomes with high-dose image guided radiotherapy compared with non-IGRT for the treatment of clinically localized prostate cancer</article-title>. <source>Int J Radiat Oncol Biol Phys</source>. (<year>2012</year>) <volume>84</volume>:<page-range>125&#x2013;9</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.ijrobp.2011.11.047</pub-id>
</citation>
</ref>
<ref id="B2">
<label>2</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bujold</surname> <given-names>A</given-names>
</name>
<name>
<surname>Craig</surname> <given-names>T</given-names>
</name>
<name>
<surname>Jaffray</surname> <given-names>D</given-names>
</name>
<name>
<surname>Dawson</surname> <given-names>LA</given-names>
</name>
</person-group>. <article-title>Image-guided radiotherapy: has it influenced patient outcomes</article-title>? <source>Semin Radiat Oncol</source>. (<year>2012</year>) <volume>22</volume>:<fpage>50</fpage>&#x2013;<lpage>61</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.semradonc.2011.09.001</pub-id>
</citation>
</ref>
<ref id="B3">
<label>3</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Nabavizadeh</surname> <given-names>N</given-names>
</name>
<name>
<surname>Elliot</surname> <given-names>DA</given-names>
</name>
<name>
<surname>Chen</surname> <given-names>Y</given-names>
</name>
<name>
<surname>Kusano</surname> <given-names>AS</given-names>
</name>
<name>
<surname>Mitin</surname> <given-names>T</given-names>
</name>
<name>
<surname>Thomas</surname> <given-names>CR</given-names>
<suffix>Jr</suffix>
</name>
<etal/>
</person-group>. <article-title>Image guided radiation therapy (IGRT) practice patterns and IGRT&#x2019;s impact on workflow and treatment planning: results from a national survey of American Society for Radiation Oncology members</article-title>. <source>Int J Radiat Oncol Biol Phys</source>. (<year>2016</year>) <volume>94</volume>:<page-range>850&#x2013;7</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.ijrobp.2015.09.035</pub-id>
</citation>
</ref>
<ref id="B4">
<label>4</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ding</surname> <given-names>GX</given-names>
</name>
<name>
<surname>Munro</surname> <given-names>P</given-names>
</name>
</person-group>. <article-title>Radiation exposure to patients from image guidance procedures and techniques to reduce the imaging dose</article-title>. <source>Radiother Oncol</source>. (<year>2013</year>) <volume>108</volume>:<page-range>91&#x2013;8</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.radonc.2013.05.034</pub-id>
</citation>
</ref>
<ref id="B5">
<label>5</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Son</surname> <given-names>K</given-names>
</name>
<name>
<surname>Kim</surname> <given-names>JS</given-names>
</name>
<name>
<surname>Lee</surname> <given-names>H</given-names>
</name>
<name>
<surname>Cho</surname> <given-names>S</given-names>
</name>
</person-group>. <article-title>Imaging dose of human organs from kV-CBCT in image-guided radiation therapy</article-title>. <source>Radiat Prot Dosimetry</source>. (<year>2017</year>) <volume>175</volume>:<fpage>194</fpage>&#x2013;<lpage>200</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1093/rpd/ncw285</pub-id>
</citation>
</ref>
<ref id="B6">
<label>6</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hess</surname> <given-names>CB</given-names>
</name>
<name>
<surname>Thompson</surname> <given-names>HM</given-names>
</name>
<name>
<surname>Benedict</surname> <given-names>SH</given-names>
</name>
<name>
<surname>Seibert</surname> <given-names>JA</given-names>
</name>
<name>
<surname>Wong</surname> <given-names>K</given-names>
</name>
<name>
<surname>Vaughan</surname> <given-names>AT</given-names>
</name>
<etal/>
</person-group>. <article-title>Exposure risks among children undergoing radiation therapy: considerations in the era of image guided radiation therapy</article-title>. <source>Int J Radiat Oncol Biol Phys</source>. (<year>2016</year>) <volume>94</volume>:<page-range>978&#x2013;92</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.ijrobp.2015.12.372</pub-id>
</citation>
</ref>
<ref id="B7">
<label>7</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Dzierma</surname> <given-names>Y</given-names>
</name>
<name>
<surname>Mikulla</surname> <given-names>K</given-names>
</name>
<name>
<surname>Richter</surname> <given-names>P</given-names>
</name>
<name>
<surname>Bell</surname> <given-names>K</given-names>
</name>
<name>
<surname>Melchior</surname> <given-names>P</given-names>
</name>
<name>
<surname>Nuesken</surname> <given-names>F</given-names>
</name>
<etal/>
</person-group>. <article-title>Imaging dose and secondary cancer risk in image-guided radiotherapy of pediatric patients</article-title>. <source>Radiat Oncol</source>. (<year>2018</year>) <volume>13</volume>:<fpage>168</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1186/s13014-018-1109-8</pub-id>
</citation>
</ref>
<ref id="B8">
<label>8</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhou</surname> <given-names>L</given-names>
</name>
<name>
<surname>Bai</surname> <given-names>S</given-names>
</name>
<name>
<surname>Zhang</surname> <given-names>Y</given-names>
</name>
<name>
<surname>Ming</surname> <given-names>X</given-names>
</name>
<name>
<surname>Zhang</surname> <given-names>Y</given-names>
</name>
<name>
<surname>Deng</surname> <given-names>J</given-names>
</name>
</person-group>. <article-title>Imaging dose, cancer risk and cost analysis in image-guided radiotherapy of cancers</article-title>. <source>Sci Rep</source>. (<year>2018</year>) <volume>8</volume>:<fpage>10076</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1038/s41598-018-28431-9</pub-id>
</citation>
</ref>
<ref id="B9">
<label>9</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hua</surname> <given-names>CH</given-names>
</name>
<name>
<surname>Vern-Gross</surname> <given-names>TZ</given-names>
</name>
<name>
<surname>Hess</surname> <given-names>CB</given-names>
</name>
<name>
<surname>Olch</surname> <given-names>AJ</given-names>
</name>
<name>
<surname>Alaei</surname> <given-names>P</given-names>
</name>
<name>
<surname>Sathiaseelan</surname> <given-names>V</given-names>
</name>
<etal/>
</person-group>. <article-title>Practice patterns and recommendations for pediatric image-guided radiotherapy: a Children&#x2019;s Oncology Group report</article-title>. <source>Pediatr Blood Cancer</source>. (<year>2020</year>) <volume>67</volume>:<fpage>e28629</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/pbc.28629</pub-id>
</citation>
</ref>
<ref id="B10">
<label>10</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ibbott</surname> <given-names>GS</given-names>
</name>
</person-group>. <article-title>Patient doses from image-guided radiation therapy</article-title>. <source>Physica Med</source>. (<year>2020</year>) <volume>72</volume>:<page-range>30&#x2013;1</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.ejmp.2020.03.005</pub-id>
</citation>
</ref>
<ref id="B11">
<label>11</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Steiner</surname> <given-names>E</given-names>
</name>
<name>
<surname>Healy</surname> <given-names>B</given-names>
</name>
<name>
<surname>Baldock</surname> <given-names>C</given-names>
</name>
</person-group>. <article-title>Dose from imaging at the time of treatment should be reduced</article-title>. <source>Phys Eng Sci Med</source>. (<year>2023</year>) <volume>46</volume>(<issue>3</issue>):<page-range>959&#x2013;62</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1007/s13246-023-01298-5</pub-id>
</citation>
</ref>
<ref id="B12">
<label>12</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Martin</surname> <given-names>CJ</given-names>
</name>
<name>
<surname>Kron</surname> <given-names>T</given-names>
</name>
<name>
<surname>Vassileva</surname> <given-names>J</given-names>
</name>
<name>
<surname>Wood</surname> <given-names>TJ</given-names>
</name>
<name>
<surname>Joyce</surname> <given-names>C</given-names>
</name>
<name>
<surname>Ung</surname> <given-names>NM</given-names>
</name>
<etal/>
</person-group>. <article-title>An international survey of imaging practices in radiotherapy</article-title>. <source>Physica Med</source>. (<year>2021</year>) <volume>90</volume>:<fpage>53</fpage>&#x2013;<lpage>65</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.ejmp.2021.09.004</pub-id>
</citation>
</ref>
<ref id="B13">
<label>13</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Murphy</surname> <given-names>MJ</given-names>
</name>
<name>
<surname>Balter</surname> <given-names>J</given-names>
</name>
<name>
<surname>Balter</surname> <given-names>S</given-names>
</name>
<name>
<surname>BenComo</surname> <given-names>JA</given-names>
<suffix>Jr</suffix>
</name>
<name>
<surname>Das</surname> <given-names>IJ</given-names>
</name>
<name>
<surname>Jiang</surname> <given-names>SB</given-names>
</name>
<etal/>
</person-group>. <article-title>The management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75</article-title>. <source>Med Phys</source>. (<year>2007</year>) <volume>34</volume>:<page-range>4041&#x2013;63</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1118/1.2775667</pub-id>
</citation>
</ref>
<ref id="B14">
<label>14</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ding</surname> <given-names>GX</given-names>
</name>
<name>
<surname>Alaei</surname> <given-names>P</given-names>
</name>
<name>
<surname>Curran</surname> <given-names>B</given-names>
</name>
<name>
<surname>Flynn</surname> <given-names>R</given-names>
</name>
<name>
<surname>Gossman</surname> <given-names>M</given-names>
</name>
<name>
<surname>Mackie</surname> <given-names>TR</given-names>
</name>
<etal/>
</person-group>. <article-title>Image guidance doses delivered during radiotherapy: Quantification, management, and reduction: Report of the AAPM Therapy Physics Committee Task Group 180</article-title>. <source>Med Phys</source>. (<year>2018</year>) <volume>45</volume>:<page-range>e84&#x2013;99</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/mp.12824</pub-id>
</citation>
</ref>
<ref id="B15">
<label>15</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wood</surname> <given-names>TJ</given-names>
</name>
<name>
<surname>Moore</surname> <given-names>CS</given-names>
</name>
<name>
<surname>Horsfield</surname> <given-names>CJ</given-names>
</name>
<name>
<surname>Saunderson</surname> <given-names>JR</given-names>
</name>
<name>
<surname>Beavis</surname> <given-names>AW</given-names>
</name>
</person-group>. <article-title>Accounting for patient size in the optimization of dose and image quality of pelvis cone beam CT protocols on the Varian OBI system</article-title>. <source>BJR Open</source>. (<year>2015</year>) <volume>88</volume>:<fpage>20150364</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1259/bjr.20150364</pub-id>
</citation>
</ref>
<ref id="B16">
<label>16</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yan</surname> <given-names>H</given-names>
</name>
<name>
<surname>Cervino</surname> <given-names>L</given-names>
</name>
<name>
<surname>Jia</surname> <given-names>X</given-names>
</name>
<name>
<surname>Jiang</surname> <given-names>SB</given-names>
</name>
</person-group>. <article-title>A comprehensive study on the relationship between the image quality and imaging dose in low-dose cone beam CT</article-title>. <source>Phys Med Biol</source>. (<year>2012</year>) <volume>57</volume>:<page-range>2063&#x2013;80</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1088/0031-9155/57/7/2063</pub-id>
</citation>
</ref>
<ref id="B17">
<label>17</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lu</surname> <given-names>B</given-names>
</name>
<name>
<surname>Lu</surname> <given-names>H</given-names>
</name>
<name>
<surname>Palta</surname> <given-names>J</given-names>
</name>
</person-group>. <article-title>A comprehensive study on decreasing the kilovoltage cone-beam CT dose by reducing the projection number</article-title>. <source>J Appl Clin Med Phys</source>. (<year>2010</year>) <volume>11</volume>:<page-range>231&#x2013;49</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1120/jacmp.v11i3.3274</pub-id>
</citation>
</ref>
<ref id="B18">
<label>18</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Men</surname> <given-names>K</given-names>
</name>
<name>
<surname>Dai</surname> <given-names>J</given-names>
</name>
</person-group>. <article-title>A projection quality-driven tube current modulation method in cone-beam CT for IGRT: proof of concept</article-title>. <source>Technol Cancer Res Treat</source>. (<year>2017</year>) <volume>16</volume>:<page-range>1179&#x2013;86</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1177/1533034617740283</pub-id>
</citation>
</ref>
<ref id="B19">
<label>19</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Olch</surname> <given-names>AJ</given-names>
</name>
<name>
<surname>Alaei</surname> <given-names>P</given-names>
</name>
</person-group>. <article-title>How low can you go? A CBCT dose reduction study</article-title>. <source>J Appl Clin Med Phys</source>. (<year>2021</year>) <volume>22</volume>:<page-range>85&#x2013;9</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/acm2.13164</pub-id>
</citation>
</ref>
<ref id="B20">
<label>20</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Alcorn</surname> <given-names>SR</given-names>
</name>
<name>
<surname>Zhou</surname> <given-names>XC</given-names>
</name>
<name>
<surname>Bojechko</surname> <given-names>C</given-names>
</name>
<name>
<surname>Rubo</surname> <given-names>RA</given-names>
</name>
<name>
<surname>Chen</surname> <given-names>MJ</given-names>
</name>
<name>
<surname>Dieckmann</surname> <given-names>K</given-names>
</name>
<etal/>
</person-group>. <article-title>Low-dose image-guided pediatric CNS radiation therapy: final analysis from a prospective low-dose cone-beam CT protocol from a multinational pediatrics consortium</article-title>. <source>Technol Cancer Res Treat</source>. (<year>2020</year>) <volume>19</volume>:<fpage>153303382092065</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1177/1533033820920650</pub-id>
</citation>
</ref>
<ref id="B21">
<label>21</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bryce-Atkinson</surname> <given-names>A</given-names>
</name>
<name>
<surname>De Jong</surname> <given-names>R</given-names>
</name>
<name>
<surname>Marchant</surname> <given-names>T</given-names>
</name>
<name>
<surname>Whitfield</surname> <given-names>G</given-names>
</name>
<name>
<surname>Aznar</surname> <given-names>MC</given-names>
</name>
<name>
<surname>Bel</surname> <given-names>A</given-names>
</name>
<etal/>
</person-group>. <article-title>Low dose cone beam CT for paediatric image-guided radiotherapy: Image quality and practical recommendations</article-title>. <source>Radiother Oncol</source>. (<year>2021</year>) <volume>163</volume>:<fpage>68</fpage>&#x2013;<lpage>75</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.radonc.2021.07.027</pub-id>
</citation>
</ref>
<ref id="B22">
<label>22</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhou</surname> <given-names>S</given-names>
</name>
<name>
<surname>Li</surname> <given-names>J</given-names>
</name>
<name>
<surname>Zhu</surname> <given-names>X</given-names>
</name>
<name>
<surname>Du</surname> <given-names>Y</given-names>
</name>
<name>
<surname>Yu</surname> <given-names>S</given-names>
</name>
<name>
<surname>Wang</surname> <given-names>M</given-names>
</name>
<etal/>
</person-group>. <article-title>Initial clinical experience of surface guided stereotactic radiation therapy with open-face mask immobilization for improving setup accuracy: a retrospective study</article-title>. <source>Radiat Oncol</source>. (<year>2022</year>) <volume>17</volume>:<fpage>104</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1186/s13014-022-02077-4</pub-id>
</citation>
</ref>
<ref id="B23">
<label>23</label>
<citation citation-type="book">
<person-group person-group-type="author">
<collab>Varian Medical Systems</collab>
</person-group>. <source>TrueBeam technical reference guide volume 2: imaging P1033684-002-B</source>. <publisher-loc>Palo Alto, CA</publisher-loc>: <publisher-name>Varian Medical Systems, Inc.</publisher-name> (<year>2022</year>).</citation>
</ref>
<ref id="B24">
<label>24</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Du</surname> <given-names>Y</given-names>
</name>
<name>
<surname>Wang</surname> <given-names>R</given-names>
</name>
<name>
<surname>Biguri</surname> <given-names>A</given-names>
</name>
<name>
<surname>Zhao</surname> <given-names>X</given-names>
</name>
<name>
<surname>Peng</surname> <given-names>Y</given-names>
</name>
<name>
<surname>Wu</surname> <given-names>H</given-names>
</name>
</person-group>. <article-title>TIGRE-VarianCBCT for on-board cone-beam computed tomography, an open-source toolkit for imaging, dosimetry and clinical research</article-title>. <source>Phys Med</source>. (<year>2022</year>) <volume>102</volume>:<fpage>33</fpage>&#x2013;<lpage>45</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.ejmp.2022.08.013</pub-id>
</citation>
</ref>
<ref id="B25">
<label>25</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Burgess</surname> <given-names>AE</given-names>
</name>
</person-group>. <article-title>The Rose model, revisited</article-title>. <source>J Opt Soc Am A Opt Image Sci Vis</source>. (<year>1999</year>) <volume>16</volume>:<page-range>633&#x2013;46</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1364/JOSAA.16.000633</pub-id>
</citation>
</ref>
<ref id="B26">
<label>26</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Fedorov</surname> <given-names>A</given-names>
</name>
<name>
<surname>Beichel</surname> <given-names>R</given-names>
</name>
<name>
<surname>Kalpathy-Cramer</surname> <given-names>J</given-names>
</name>
<name>
<surname>Finet</surname> <given-names>J</given-names>
</name>
<name>
<surname>Fillion-Robin</surname> <given-names>JC</given-names>
</name>
<name>
<surname>Pujol</surname> <given-names>S</given-names>
</name>
<etal/>
</person-group>. <article-title>3D Slicer as an image computing platform for the Quantitative Imaging Network</article-title>. <source>Magn Reson Imaging</source>. (<year>2012</year>) <volume>30</volume>:<page-range>1323&#x2013;41</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.mri.2012.05.001</pub-id>
</citation>
</ref>
</ref-list>
</back>
</article>