<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" article-type="research-article" dtd-version="2.3" xml:lang="EN">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Oncol.</journal-id>
<journal-title>Frontiers in Oncology</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Oncol.</abbrev-journal-title>
<issn pub-type="epub">2234-943X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fonc.2023.1108142</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Oncology</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Evaluation of flattening-filter-free and flattening filter dosimetric and radiobiological criteria for lung SBRT: A volume-based analysis</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Wu</surname>
<given-names>Junxiang</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="author-notes" rid="fn003">
<sup>&#x2020;</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/2114699"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Song</surname>
<given-names>Hongchang</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<xref ref-type="author-notes" rid="fn003">
<sup>&#x2020;</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Li</surname>
<given-names>Jie</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/958945"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Tang</surname>
<given-names>Bin</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1583673"/>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Wu</surname>
<given-names>Fan</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="author-notes" rid="fn001">
<sup>*</sup>
</xref>
</contrib>
</contrib-group>
<aff id="aff1">
<sup>1</sup>
<institution>Radiation Oncology Key Laboratory of Sichuan Province, Sichuan Cancer Hospital &amp; Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China</institution>, <addr-line>Chengdu</addr-line>, <country>China</country>
</aff>
<aff id="aff2">
<sup>2</sup>
<institution>Department of Oncology, Xichang People&#x2019;s Hospital</institution>, <addr-line>Xichang</addr-line>, <country>China</country>
</aff>
<author-notes>
<fn fn-type="edited-by">
<p>Edited by: Ferenc Lakosi, Somogy County Kaposi M&#xf3;r Teaching Hospital, Hungary</p>
</fn>
<fn fn-type="edited-by">
<p>Reviewed by: Yvonne Dzierma, Saarland University Hospital, Germany; Vanessa Panettieri, The Alfred Hospital, Australia</p>
</fn>
<fn fn-type="corresp" id="fn001">
<p>*Correspondence: Fan Wu, <email xlink:href="mailto:huaomaru@163.com">huaomaru@163.com</email>
</p>
</fn>
<fn fn-type="equal" id="fn003">
<p>&#x2020;These authors have have contributed equally to this work</p>
</fn>
<fn fn-type="other" id="fn002">
<p>This article was submitted to Radiation Oncology, a section of the journal Frontiers in Oncology</p>
</fn>
</author-notes>
<pub-date pub-type="epub">
<day>24</day>
<month>01</month>
<year>2023</year>
</pub-date>
<pub-date pub-type="collection">
<year>2023</year>
</pub-date>
<volume>13</volume>
<elocation-id>1108142</elocation-id>
<history>
<date date-type="received">
<day>25</day>
<month>11</month>
<year>2022</year>
</date>
<date date-type="accepted">
<day>06</day>
<month>01</month>
<year>2023</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2023 Wu, Song, Li, Tang and Wu</copyright-statement>
<copyright-year>2023</copyright-year>
<copyright-holder>Wu, Song, Li, Tang and Wu</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<sec>
<title>Introduction</title>
<p>The use of volumetric modulated arc therapy (VMAT) with flattening-filter-free (FFF) beams is becoming more prevalent in lung cancer stereotactic body radiotherapy (SBRT). The aim in this study was to assess the impact of dosimetric and radiobiological differences between FFF and flattening filter (FF) beams for lung SBRT based on the target volume.</p>
</sec>
<sec>
<title>Methods</title>
<p>A total of 198 lung stereotactic body radiation therapy treatment plans with FFF beams and FF beams were retrospectively selected for this study. For all plans, the prescribed dose was 50 Gy/5 fractions, and the dose volume histogram (DVH) for the target and organs at risk (OAR) and the normal tissue complication probability (NTCP) of the lung were recorded and compared. Moreover, monitor units (MUs), the beam on-time and the treatment time were evaluated.</p>
</sec>
<sec>
<title>Results</title>
<p>The study was performed following the Radiation Therapy Oncology Group (RTOG) 0813 and 0915 protocols. No significant differences in D<sub>90</sub>, coverage rate (CR) or conformity index (CI) of the target were observed between FFF beams and FF beams (<italic>p</italic>&gt;0.05). The D<sub>2</sub>, R<sub>50%</sub> and gradient index (GI) for the target improved with FFF beams compared with FF beams (<italic>p</italic>&lt;0.05). FFF beams also significantly reduced the dose for the lung, heart, spinal cord, esophagus and NTCP of the lung (<italic>p</italic>&lt;0.05), compared with FF beams. However, there was no significant difference in sparing of the trachea (<italic>p</italic>&gt;0.05). The mean MUs, beam on-time and treatment time were 1871 &#xb1; 278 MUs, 3.2 &#xb1; 0.2&#xa0;min and 3.9 &#xb1; 0.3&#xa0;min for FFF beams, and 1890 &#xb1; 260 MUs, 4.2 &#xb1; 0.3&#xa0;min and 4.8 &#xb1; 0.4&#xa0;min for FF beams, respectively.</p>
</sec>
<sec>
<title>Discussion</title>
<p>The FFF beam technique for lung SBRT with VMAT results in a better dose fall-off, better dose-sparing of OAR, lower NTCP of the lung and a shorter beam on-time compared with the FF beam technique. Additionally, the improvement in target and OAR-sparing for FFF beams was increased with increasing target volume.</p>
</sec>
</abstract>
<kwd-group>
<kwd>SBRT</kwd>
<kwd>lung cancer</kwd>
<kwd>FFF beams</kwd>
<kwd>VMAT</kwd>
<kwd>NTCP</kwd>
</kwd-group>
<contract-sponsor id="cn001">Sichuan Province Science and Technology Support Program<named-content content-type="fundref-id">10.13039/100012542</named-content>
</contract-sponsor>
<contract-sponsor id="cn002">Sichuan Province Science and Technology Support Program<named-content content-type="fundref-id">10.13039/100012542</named-content>
</contract-sponsor>
<contract-sponsor id="cn003">Sichuan Province Science and Technology Support Program<named-content content-type="fundref-id">10.13039/100012542</named-content>
</contract-sponsor>
<counts>
<fig-count count="6"/>
<table-count count="6"/>
<equation-count count="8"/>
<ref-count count="38"/>
<page-count count="11"/>
<word-count count="6352"/>
</counts>
</article-meta>
</front>
<body>
<sec id="s1" sec-type="intro">
<title>Introduction</title>
<p>Among Chinese men, lung cancer is the most common cancer, accounting for about 24.6% of all new cancer cases, according to data released in 2022 by the Chinese National Cancer Center (<xref ref-type="bibr" rid="B1">1</xref>). The use of stereotactic body radiation therapy (SBRT) has become the standard treatment for medically inoperable, early stage, non-small-cell lung cancer (NSCLC) (<xref ref-type="bibr" rid="B2">2</xref>&#x2013;<xref ref-type="bibr" rid="B4">4</xref>). Compared to conventional radiation therapy, SBRT has the major feature of delivering large doses, while minimizing the dose to the organs at risk (OAR) (<xref ref-type="bibr" rid="B5">5</xref>&#x2013;<xref ref-type="bibr" rid="B7">7</xref>). However, with the delivery of large doses, which results in a prolonged beam on-time, it could impact patient safety, such as patient motion, and the succeeding risk of dose uncertainties increases. The crucial challenges of SBRT concern safety, accuracy, and speed.</p>
<p>Due to advances in technology, there has been growing interest in the clinical use of flattening-filter-free (FFF) beams to deliver lung SBRT treatment (<xref ref-type="bibr" rid="B8">8</xref>&#x2013;<xref ref-type="bibr" rid="B10">10</xref>). The FFF beam has had the flattening filter removed, such that the beam is not flat, as flatness is not necessary for volumetric modulated arc therapy (VMAT). The main characteristics of FFF beams are the high dose rate (1400 monitor units per minute for 6 MV photon beam), a cone-shaped dose profile (<xref ref-type="bibr" rid="B11">11</xref>), reduced peripheral dose outside of the beam (<xref ref-type="bibr" rid="B12">12</xref>) and an increased superficial dose. The most notable results of FFF beams are the large reduction in beam on-time, increased clinical efficiency, a better target dose coverage and OAR-sparing (<xref ref-type="bibr" rid="B8">8</xref>, <xref ref-type="bibr" rid="B10">10</xref>, <xref ref-type="bibr" rid="B13">13</xref>, <xref ref-type="bibr" rid="B14">14</xref>).</p>
<p>With these advantages of FFF beams, many researchers have studied the dosimetry of FFF beams and FF beams in lung SBRT (<xref ref-type="bibr" rid="B8">8</xref>, <xref ref-type="bibr" rid="B15">15</xref>, <xref ref-type="bibr" rid="B16">16</xref>). However, according to a previous paper (<xref ref-type="bibr" rid="B17">17</xref>) and our experience, the difference in plan quality between FFF beams and FF beams is dependent on PTV. Only Reggiori et&#xa0;al. (<xref ref-type="bibr" rid="B17">17</xref>) have compared FFF beams with FF beams based on PTV for liver SBRT. To the best of our knowledge, there have been few studies evaluating the dosimetric and radiobiological differences between FFF beams and FF beams for lung SBRT based on PTV. Treatment plan evaluation metrics for lung SBRT were recommended by the Radiation Therapy Oncology Group (RTOG) 0813 and 0915 protocols; these include R<sub>50%</sub>, the gradient index (GI), the conformity index (CI), and the coverage rate (CR) for PTV, and dose volume limits for OAR (<xref ref-type="bibr" rid="B18">18</xref>, <xref ref-type="bibr" rid="B19">19</xref>). Furthermore, the normal tissue complication probability (NTCP) for the lung was evaluated between FFF beams and FF beams. The patients were divided into four groups according to the 0813 and 0915 protocols, as Group1 (3.8 cm<sup>3</sup>&#x2264;PTV&lt;7.4 cm<sup>3</sup>), Group 2(7.4 cm<sup>3</sup>&#x2264;PTV&lt;13.2 cm<sup>3</sup>), Group 3(13.2 cm<sup>3</sup>&#x2264;PTV&lt;22.0 cm<sup>3</sup>) and Group 4(22.0 cm<sup>3</sup>&#x2264;PTV &#x2264; 34.0 cm<sup>3</sup>). In this work, we retrospectively compared the dosimetry and NTCP of 175 lung SBRT patients, using VMAT with FFF beams and FF beams dependent on PTV.</p>
</sec>
<sec id="s2" sec-type="materials|methods">
<title>Materials and methods</title>
<sec id="s2_1">
<title>Patients</title>
<p>175 patient with 198 pulmonary lesions (198 independent isocentre) treated with SBRT using either FFF or FF beams during June 2021 to March 2022 were included in the study. This retrospective study was approved by the Ethics Committee of our hospital. Patient characteristics are summarized in <xref ref-type="table" rid="T1">
<bold>Table&#xa0;1</bold>
</xref>. The patients were immobilized in a supine position with their arms above their head. All patients received two computed tomography (CT) scans: a free-breathing CT scan and a four-dimensional CT scan (4DCT). CT scans with a 3&#xa0;mm slice thickness were acquired with a 16-slice Brilliance Big Bore CT (Philips Medical Systems, Cleveland, OH, USA). All 10 phases of the 4DCT slices and respiratory motion data were transferred to MIM Maestro software (MIM Software Inc., Cleveland, OH, USA) using 4D Workflow, where the maximum intensity projection (MIP) images and average intensity projection (AIP) images were generated. Visible lesions on CT were used to determine the gross tumor volume (GTV) using the window/level settings on the lung (window/level ranges from 800 to 1600 HU or -600 to -750 HU), and the GTV and clinical target volume (CTV) was often considered to be equal (<xref ref-type="bibr" rid="B20">20</xref>, <xref ref-type="bibr" rid="B21">21</xref>). CTVs from 4DCT were contoured on CT images of each respiratory phase (CTV0, CTV10 to CTV90) and added together to define the internal target volume (ITV). The planning target volume (PTV) was generated by expanding 5&#xa0;mm in three dimensions to ITV. The volume for the PTV range was from 5.07 to 33.49 cc (mean 14.63 &#xb1; 5.25 cc), and the detail of the PTV is shown in <xref ref-type="table" rid="T1">
<bold>Table&#xa0;1</bold>
</xref>. The patients were stratified into four groups according to the RTOG 0813 protocol by the volume lesion: the first group included 7 patients with a PTV from 3.8 to 7.4 cm<sup>3</sup>, the second group included 83 patients with a PTV from 7.4 to 13.2 cm<sup>3</sup>, the third group included 91 patients with a PTV from 13.2 to 22.0 cm<sup>3</sup>, and the fourth group included 17 patients with a PTV from 22.0 to 34.0 cm<sup>3</sup>. The OAR of this study were contoured on the CT image, which included the lung, heart, spinal cord, esophagus and trachea.</p>
<table-wrap id="T1" position="float">
<label>Table&#xa0;1</label>
<caption>
<p>Patient characteristics of 175 patients with 198 pulmonary lesions.</p>
</caption>
<table frame="hsides">
<thead>
<tr>
<th valign="top" colspan="4" align="left">Patients</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left" colspan="2" style="background-color:#dfe4e5">Sex</td>
<td valign="top" align="left" colspan="2" style="background-color:#dfe4e5">Tumors site</td>
</tr>
<tr>
<td valign="top" align="left">Male</td>
<td valign="top" align="center">115 (65.7%)</td>
<td valign="top" align="left">Left lung</td>
<td valign="top" align="center">100 (50.5%)</td>
</tr>
<tr>
<td valign="top" align="left">Female</td>
<td valign="top" align="center">60 (34.3%)</td>
<td valign="top" align="left">Right lung</td>
<td valign="top" align="center">98 (49.5%)</td>
</tr>
<tr>
<td valign="top" align="left" colspan="2" style="background-color:#dfe4e5">Age</td>
<td valign="top" align="left">Peripheral</td>
<td valign="top" align="center">181 (91.4%)</td>
</tr>
<tr>
<td valign="top" align="left">&#x2264;50</td>
<td valign="top" align="center">60 (34.3%)</td>
<td valign="top" align="left">Central</td>
<td valign="top" align="center">17 (8.6%)</td>
</tr>
<tr>
<td valign="top" align="left">&gt;50</td>
<td valign="top" align="center">115 (65.7%)</td>
<td valign="top" align="left" colspan="2" style="background-color:#dfe4e5">Primary tumors</td>
</tr>
<tr>
<td valign="top" align="left" colspan="2" style="background-color:#dfe4e5">PTV volume (cc)</td>
<td valign="top" align="left">Lung</td>
<td valign="top" align="center">135 (77.1%)</td>
</tr>
<tr>
<td valign="top" align="left">Group1 (3.8 &#x2264; PTV&lt; 7.4)</td>
<td valign="top" align="center">7 (3.5%)</td>
<td valign="top" align="left">Liver</td>
<td valign="top" align="center">25 (14.3%)</td>
</tr>
<tr>
<td valign="top" align="left">Group2 (7.4 &#x2264; PTV&lt; 13.2)</td>
<td valign="top" align="center">83 (41.9%)</td>
<td valign="top" align="left">Stomach</td>
<td valign="top" align="center">5 (2.9%)</td>
</tr>
<tr>
<td valign="top" align="left">Group3 (13.2 &#x2264; PTV&lt; 22.0)</td>
<td valign="top" align="center">91 (46.0%)</td>
<td valign="top" align="left">Breast</td>
<td valign="top" align="center">6 (3.4%)</td>
</tr>
<tr>
<td valign="top" align="left">Group4 (22.0 &#x2264; PTV &#x2264; 34.0)</td>
<td valign="top" align="center">17 (8.6%)</td>
<td valign="top" align="left">Unknown</td>
<td valign="top" align="center">4 (2.3%)</td>
</tr>
<tr>
<td valign="top" colspan="2" align="left" style="background-color:#dfe4e5">Originally treated beams</td>
<td valign="top" align="center"/>
<td valign="top" align="center"/>
</tr>
<tr>
<td valign="top" align="left">FFF beams</td>
<td valign="top" align="center">177 (89.4%)</td>
<td valign="top" align="center"/>
<td valign="top" align="center"/>
</tr>
<tr>
<td valign="top" align="left">FF beams</td>
<td valign="top" align="center">21 (10.6%)</td>
<td valign="top" align="center"/>
<td valign="top" align="center"/>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
<sec id="s2_2">
<title>Treatment planning</title>
<p>All clinical treatment plans were generated using the Pinnacle TPS (version 9.10, Philips Radiation Oncology Systems, Fitchburg, WI, USA). Intensity modulation was performed using the direct machine parameter optimization (DMPO) algorithm. The collapsed cone (CC) algorithm was applied for final dose calculations, with a grid size of 2.5&#xa0;mm. For each patient, two plans were created:1) a triple VMAT arc using FFF beams (VMAT<sub>FFF</sub>) with collimator 0&#xb0; and couch 0&#xb0;; and 2) a triple VAMT arc using FF beams (VMAT<sub>FF</sub>) with collimator 0&#xb0; and couch 0&#xb0;. The treatment beam was a non-coplanar6MV photon using the Infinity Linear Accelerator (Elekta AB, Sweden). The Infinity Linear Accelerator is equipped with a multileaf collimator, MLCi2, which has 40 leaf pairs of 0.5&#xa0;cm thickness. The maximum dose rate of the FFF beams and FF beams was 1400 and 600 monitor units (MU)/min for 6 MV photons at the Elekta Infinity linear accelerator, respectively. VMAT<sub>FFF</sub> and VMAT<sub>FF</sub> plans were generated using 3 arcs; for example, when the target was in the right lung, the arcs were as follows: 1) located in the lower region of the lung with 3 partial arcs, the first of which was clockwise from 181&#x2da; to 300&#x2da;, the second was counterclockwise from 300&#x2da; to 181&#x2da;, and the third was clockwise from 120&#x2da; to 179&#x2da;; 2) located in the upper region of the lung, with 3 partial arcs, the first of which was clockwise from 250&#x2da; to 30&#x2da;, with the same range of angles for arc 2 and arc 3; and 3) located near the midline of the body with 3 full arcs, from 181&#x2da; to 179&#x2da;.The arcs for right lung are presented in <xref ref-type="fig" rid="f1">
<bold>Figure&#xa0;1</bold>
</xref>.</p>
<fig id="f1" position="float">
<label>Figure&#xa0;1</label>
<caption>
<p>The arcs for right lung for FFF beams and FF beams. <bold>(A)</bold> the lower region of the lung. <bold>(B)</bold> the upper region of the lung. <bold>(C)</bold> the midline of the body.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fonc-13-1108142-g001.tif"/>
</fig>
<p>The penalties and weights for the target and OAR, and the number of iterations were kept the same for the VMAT<sub>FFF</sub> and VMAT<sub>FF</sub> plans. The prescribed dose was 50 Gy in 5 fractions aimed to cover the PTV with 90% of the prescribed dose (D<sub>90</sub>).The dose constraints for the PTV were1) D<sub>90</sub>&#x2265;100% of the prescribed dose, and 2) D<sub>2</sub> &#x2264; 125% of the prescribed dose. For the OAR, both the VMAT<sub>FFF</sub> and VMAT<sub>FF</sub> plans met the dose volume limits of the RTOG 0813/0915 protocols, as detailed in <xref ref-type="table" rid="T2">
<bold>Table&#xa0;2</bold>
</xref>.</p>
<table-wrap id="T2" position="float">
<label>Table&#xa0;2</label>
<caption>
<p>Dose-volume constraints for OARs.</p>
</caption>
<table frame="hsides">
<thead>
<tr>
<th valign="middle" align="left">OARs</th>
<th valign="middle" align="center">Dose volume parameters</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="middle" align="left">Spinal cord</td>
<td valign="middle" align="center">D<sub>0.25cc</sub>&lt;22.5 Gy, D<sub>0.5cc</sub>&lt;13.5 Gy, D<sub>max</sub>&lt;30 Gy</td>
</tr>
<tr>
<td valign="middle" align="left">Lung</td>
<td valign="middle" align="center">D<sub>1500cc</sub>&lt;12.5 Gy, D<sub>1000cc</sub>&lt;13.5 Gy</td>
</tr>
<tr>
<td valign="middle" align="left">Esophagus</td>
<td valign="middle" align="center">D<sub>5cc</sub>&lt;27.5 Gy</td>
</tr>
<tr>
<td valign="middle" align="left">Heart</td>
<td valign="middle" align="center">D<sub>15cc</sub>&lt;32 Gy</td>
</tr>
<tr>
<td valign="middle" align="left">Trachea</td>
<td valign="middle" align="center">D<sub>4cc</sub>&lt;18 Gy</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
<sec id="s2_3">
<title>Evaluation of dosimetric data</title>
<p>The dosimetric quality of the treatments were measured using a dose volume histogram (DVH) metrics. For PTV, the target coverage (D<sub>90</sub> and D<sub>2</sub>), the coverage rate (CR), the conformity index (CI), R<sub>50%</sub> and the gradient index (GI) were reported (<xref ref-type="bibr" rid="B22">22</xref>&#x2013;<xref ref-type="bibr" rid="B24">24</xref>).</p>
<p>CR was defined as:</p>
<disp-formula>
<label>(1)</label>
<mml:math display="block" id="M1">
<mml:mrow>
<mml:mtext>CR</mml:mtext>
<mml:mo>=</mml:mo>
<mml:mtext>T</mml:mtext>
<mml:msub>
<mml:mtext>V</mml:mtext>
<mml:mrow>
<mml:mtext>PV</mml:mtext>
</mml:mrow>
</mml:msub>
<mml:mo stretchy="false">/</mml:mo>
<mml:mtext>TV</mml:mtext>
</mml:mrow>
</mml:math>
</disp-formula>
<p>where TV<sub>PV</sub> is the target volume covered by the prescription isodose and TV is the volume of the target.</p>
<p>CI was defined as:</p>
<disp-formula>
<label>(2)</label>
<mml:math display="block" id="M2">
<mml:mrow>
<mml:mtext>CI</mml:mtext>
<mml:mo>=</mml:mo>
<mml:msup>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mtext>T</mml:mtext>
<mml:msub>
<mml:mtext>V</mml:mtext>
<mml:mrow>
<mml:mtext>PV</mml:mtext>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msup>
<mml:mo stretchy="false">/</mml:mo>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mtext>TV</mml:mtext>
<mml:mo>&#xd7;</mml:mo>
<mml:mtext>PV</mml:mtext>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:math>
</disp-formula>
<p>where PV is the volume covered by the prescription isodose. CI values range between 0 and 1, and a CI close to 1 represents better conformity. GI was defined as the ratio of the volume of half the prescription isodose and the TV<sub>PV.</sub> R<sub>50%</sub> was calculated using the RTOG 0813 protocol (<xref ref-type="bibr" rid="B18">18</xref>), and it was defined as the ratio of 50% prescription isodose volume to the PTV. Furthermore, dosimetric parameters were evaluated for the lung, spinal cord, esophagus, heart and trachea. The dose to the lung was evaluated using V<sub>5</sub>, V<sub>20</sub>, D<sub>1000cc</sub>, D<sub>1500cc</sub> and the mean lung dose (MLD). D<sub>max</sub>, D<sub>0.25cc</sub> and D<sub>0.5cc</sub> of spinal cord were recorded. For the esophagus, heart and trachea, the D<sub>max</sub>, D<sub>5cc</sub>, D<sub>1500cc</sub> and D<sub>4cc</sub> were scored, respectively. Moreover, monitor units (MUs),the beam on-time (BOT) and the treatment time for the two plans were also recorded.</p>
</sec>
<sec id="s2_4">
<title>Evaluation of NTCP data</title>
<p>The NTCP for &#x2265; grade 2 radiation pneumonitis (RP) of the lung was assessed for VMAT<sub>FFF</sub> and VMAT<sub>FF</sub> plans. For all patients, we exported DVHs of the lung to convert the physical dose into the biologically effective dose (BED) (<xref ref-type="bibr" rid="B25">25</xref>), using the LQ model and &#x3b1;/&#x3b2;-ratio of 3 Gy (<xref ref-type="bibr" rid="B26">26</xref>), as follows:</p>
<disp-formula>
<label>(3)</label>
<mml:math display="block" id="M3">
<mml:mrow>
<mml:mtext>BED=D</mml:mtext>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mn>1+</mml:mn>
<mml:mfrac>
<mml:mtext>d</mml:mtext>
<mml:mrow>
<mml:mtext>&#x3b1;/&#x3b2;</mml:mtext>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mo>&#xa0;</mml:mo>
<mml:mo>&#xa0;</mml:mo>
<mml:mo>&#xa0;</mml:mo>
<mml:mo>&#xa0;</mml:mo>
<mml:mo>&#xa0;</mml:mo>
<mml:mo>&#xa0;</mml:mo>
<mml:mo>&#xa0;</mml:mo>
</mml:mrow>
</mml:math>
</disp-formula>
<p>in which the total dose (D) is the dose per fraction (d) multiplied by the number of fractions (n). The Lyman&#x2013;Kutcher&#x2013;Burman (LKB) model of NTCP (<xref ref-type="bibr" rid="B27">27</xref>) can be calculated from the EUD or V<sub>x</sub> according to:</p>
<disp-formula>
<label>(4)</label>
<mml:math display="block" id="M4">
<mml:mrow>
<mml:mtext>NTCP=</mml:mtext>
<mml:mfrac>
<mml:mn>1</mml:mn>
<mml:mrow>
<mml:msqrt>
<mml:mrow>
<mml:mn>2&#x3c0;</mml:mn>
</mml:mrow>
</mml:msqrt>
</mml:mrow>
</mml:mfrac>
<mml:munderover>
<mml:mo>&#x222b;</mml:mo>
<mml:mrow>
<mml:mo>-</mml:mo>
<mml:mi>&#x221e;</mml:mi>
</mml:mrow>
<mml:mtext>t</mml:mtext>
</mml:munderover>
<mml:msup>
<mml:mtext>e</mml:mtext>
<mml:mrow>
<mml:mfrac>
<mml:mrow>
<mml:mo>&#x2212;</mml:mo>
<mml:msup>
<mml:mtext>x</mml:mtext>
<mml:mn>2</mml:mn>
</mml:msup>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:mfrac>
</mml:mrow>
</mml:msup>
<mml:mtext>dx</mml:mtext>
</mml:mrow>
</mml:math>
</disp-formula>
<p>With</p>
<disp-formula>
<mml:math display="block" id="M5">
<mml:mrow>
<mml:mtext>t=</mml:mtext>
<mml:mrow>
<mml:mo>{</mml:mo>
<mml:mrow>
<mml:mtable>
<mml:mtr>
<mml:mtd>
<mml:mrow>
<mml:mfrac>
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mtext>EUD-TD</mml:mtext>
</mml:mrow>
<mml:mrow>
<mml:mn>50</mml:mn>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mrow>
<mml:mtext>m</mml:mtext>
<mml:mo>&#xb7;</mml:mo>
<mml:msub>
<mml:mrow>
<mml:mtext>TD</mml:mtext>
</mml:mrow>
<mml:mrow>
<mml:mn>50</mml:mn>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:mfrac>
<mml:mtext>&#xa0;,&#xa0;&#xa0;&#xa0;&#xa0;for&#xa0;MLD</mml:mtext>
</mml:mrow>
</mml:mtd>
</mml:mtr>
<mml:mtr>
<mml:mtd>
<mml:mrow>
<mml:mo>&#xa0;</mml:mo>
<mml:mo>&#xa0;</mml:mo>
<mml:mo>&#xa0;</mml:mo>
<mml:mo>&#xa0;</mml:mo>
<mml:mo>&#xa0;</mml:mo>
<mml:mo>&#xa0;</mml:mo>
<mml:mo>&#xa0;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:msub>
<mml:mtext>V</mml:mtext>
<mml:mtext>x</mml:mtext>
</mml:msub>
<mml:msub>
<mml:mrow>
<mml:mtext>-V</mml:mtext>
</mml:mrow>
<mml:mrow>
<mml:mn>x50</mml:mn>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mrow>
<mml:mtext>m</mml:mtext>
<mml:mo>&#xb7;</mml:mo>
<mml:msub>
<mml:mtext>V</mml:mtext>
<mml:mrow>
<mml:mn>x50</mml:mn>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:mfrac>
<mml:msub>
<mml:mrow>
<mml:mtext>&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;,for&#xa0;V</mml:mtext>
</mml:mrow>
<mml:mn>5</mml:mn>
</mml:msub>
<mml:msub>
<mml:mrow>
<mml:mtext>,&#xa0;and&#xa0;V</mml:mtext>
</mml:mrow>
<mml:mrow>
<mml:mn>20</mml:mn>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:mtd>
</mml:mtr>
</mml:mtable>
</mml:mrow>
</mml:mrow>
</mml:mrow>
</mml:math>
</disp-formula>
<p>In Equation (4), the MLD (BED-corrected) can be used instead of the EUD to calculate the NTCP, according to Seppenwoolde et&#xa0;al. (<xref ref-type="bibr" rid="B28">28</xref>). TD<sub>50</sub>, the mean dose for 50%of the NTCP, and m, a slope parameter (the steepness of the curve decreases with increasing m), were 20.8 Gy and 0.45, respectively, for the equation based on MLD, as proposed by Borst et&#xa0;al. (<xref ref-type="bibr" rid="B26">26</xref>). V<sub>x50</sub> represents the V<sub>x</sub> parameter for 50% of the NTCP. The parameters for the NTCP model are given in <xref ref-type="table" rid="T3">
<bold>Table&#xa0;3</bold>
</xref>.</p>
<table-wrap id="T3" position="float">
<label>Table&#xa0;3</label>
<caption>
<p>Parameters used to calculate NTCP.</p>
</caption>
<table frame="hsides">
<thead>
<tr>
<th valign="top" align="left">Type</th>
<th valign="top" align="center">m</th>
<th valign="top" align="center">TD<sub>50</sub>
</th>
<th valign="top" align="center">V<sub>x50</sub>
</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">MLD</td>
<td valign="top" align="center">0.45</td>
<td valign="top" align="center">20.8</td>
<td valign="top" align="center">&#x2013;</td>
</tr>
<tr>
<td valign="top" align="left">V<sub>5</sub>
</td>
<td valign="top" align="center">0.46</td>
<td valign="top" align="center">&#x2013;</td>
<td valign="top" align="center">65.4</td>
</tr>
<tr>
<td valign="top" align="left">V<sub>20</sub>
</td>
<td valign="top" align="center">0.50</td>
<td valign="top" align="center">&#x2013;</td>
<td valign="top" align="center">30.6</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>Data were statistically analyzed using SPSS 19.0 software (IBM, New York, USA). A paired t-test(two-sided) was used for analyzing the dosimetric and radiobiological parameters of the PTV and OAR between VMAT<sub>FFF</sub> and VMAT<sub>FF</sub> plans with normal distribution. A value of <italic>p</italic>&lt;0.05 was considered to be significant.</p>
</sec>
</sec>
<sec id="s3" sec-type="results">
<title>Results</title>
<sec id="s3_1">
<title>Dosimetric evaluation of PTV</title>
<p>All plans were normalized to cover 90% of the PTV with the prescribed dose and met the planning objectives, as described in <xref ref-type="table" rid="T2">
<bold>Table&#xa0;2</bold>
</xref>.A comparison of the PTV and OAR dosimetric parameters for the VMAT<sub>FFF</sub> and VMAT<sub>FF</sub> plans for all 198 lung SBRT plans(generated on 175 patients with 198 independent isocentre) is presented in <xref ref-type="table" rid="T4">
<bold>Table&#xa0;4</bold>
</xref>. In general, the dose within the PTV was similar for the VMAT<sub>FFF</sub> plan and the VMAT<sub>FF</sub> plan. There was no significant difference in D<sub>90</sub>, CR and the CI of the PTV between the two plans (<italic>p</italic>&gt;0.05). However, the D<sub>2</sub>, R<sub>50%</sub> and GI of the VMAT<sub>FFF</sub> plan were significantly lower than the VMAT<sub>FF</sub> plan (<italic>p</italic>&lt;0.05). D<sub>2</sub> of the PTV was 55.30 &#xb1; 0.45 Gy for the VMAT<sub>FFF</sub> plan and 55.90 &#xb1; 0.50 Gy for the VMAT<sub>FF</sub> plan. R<sub>50%</sub> of the PTV was 4.88 &#xb1; 0.61 for the VMAT<sub>FFF</sub> plan and 4.98 &#xb1; 0.64 for the VMAT<sub>FF</sub> plan. GI of the PTV was 5.21 &#xb1; 0.73 for the VMAT<sub>FFF</sub> plan and 5.33 &#xb1; 0.78 for the VMAT<sub>FF</sub> plan.</p>
<table-wrap id="T4" position="float">
<label>Table&#xa0;4</label>
<caption>
<p>Comparison of the dosimetric parameters (mean &#xb1; standard)of PTV and OARs.</p>
</caption>
<table frame="hsides">
<thead>
<tr>
<th valign="middle" align="left"/>
<th valign="middle" align="center">Parameters</th>
<th valign="middle" align="center">VMAT<sub>FFF</sub> (range)</th>
<th valign="middle" align="center">VMAT<sub>FF</sub> (range)</th>
<th valign="middle" align="center">
<italic>p</italic>
</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="middle" rowspan="6" align="left">PTV</td>
<td valign="middle" align="left">D<sub>90</sub> (Gy)</td>
<td valign="middle" align="center">50.0 &#xb1; 0.21 (50.0-50.12)</td>
<td valign="middle" align="center">50.0 &#xb1; 0.21 (50.0-50.13)</td>
<td valign="middle" align="center">0.35</td>
</tr>
<tr>
<td valign="middle" align="left">D<sub>2</sub> (Gy)</td>
<td valign="middle" align="center">55.30 &#xb1; 0.45 (54.52-56.42)</td>
<td valign="middle" align="center">55.90 &#xb1; 0.50 (54.68-57.52)</td>
<td valign="middle" align="center">&lt;0.001</td>
</tr>
<tr>
<td valign="middle" align="left">CR</td>
<td valign="middle" align="center">0.85 &#xb1; 0.02 (0.80-0.95)</td>
<td valign="middle" align="center">0.86 &#xb1; 0.02 (0.79-0.92)</td>
<td valign="middle" align="center">0.21</td>
</tr>
<tr>
<td valign="middle" align="left">CI</td>
<td valign="middle" align="center">0.78 &#xb1; 0.06 (0.62-0.91)</td>
<td valign="middle" align="center">0.78 &#xb1; 0.07 (0.63-0.92)</td>
<td valign="middle" align="center">0.15</td>
</tr>
<tr>
<td valign="middle" align="left">R<sub>50%</sub>
</td>
<td valign="middle" align="center">4.88 &#xb1; 0.61 (3.29-6.72)</td>
<td valign="middle" align="center">4.98 &#xb1; 0.64 (3.96-6.88)</td>
<td valign="middle" align="center">&lt;0.001</td>
</tr>
<tr>
<td valign="middle" align="left">GI</td>
<td valign="middle" align="center">5.21 &#xb1; 0.73 (3.52-6.64)</td>
<td valign="middle" align="center">5.33 &#xb1; 0.78 (3.55-6.91)</td>
<td valign="middle" align="center">&lt;0.001</td>
</tr>
<tr>
<td valign="middle" rowspan="3" align="left">Spinal cord</td>
<td valign="middle" align="left">D<sub>max</sub>(Gy)</td>
<td valign="middle" align="center">7.29 &#xb1; 4.37 (1.52-26.46)</td>
<td valign="middle" align="center">7.44 &#xb1; 4.42 (1.63-26.55)</td>
<td valign="middle" align="center">&lt;0.001</td>
</tr>
<tr>
<td valign="middle" align="left">D<sub>0.25cc</sub>(Gy)</td>
<td valign="middle" align="center">6.60 &#xb1; 3.85 (1.23-22.7)</td>
<td valign="middle" align="center">6.81 &#xb1; 3.93 (1.3-22.75)</td>
<td valign="middle" align="center">&lt;0.001</td>
</tr>
<tr>
<td valign="middle" align="left">D<sub>0.5cc</sub> (Gy)</td>
<td valign="middle" align="center">6.37 &#xb1; 3.66 (1.05-21.62)</td>
<td valign="middle" align="center">6.60 &#xb1; 3.88 (1.1-21.56)</td>
<td valign="middle" align="center">&lt;0.001</td>
</tr>
<tr>
<td valign="middle" rowspan="2" align="left">Esophagus</td>
<td valign="middle" align="left">D<sub>max</sub>(Gy)</td>
<td valign="middle" align="center">6.95 &#xb1; 4.43 (0.04-24.72)</td>
<td valign="middle" align="center">7.08 &#xb1; 4.39 (0.05-23.94)</td>
<td valign="middle" align="center">0.011</td>
</tr>
<tr>
<td valign="middle" align="left">D<sub>5cc</sub> (Gy)</td>
<td valign="middle" align="center">3.71 &#xb1; 2.67 (0.37-16.13)</td>
<td valign="middle" align="center">3.81 &#xb1; 2.72 (0.44-15.74)</td>
<td valign="middle" align="center">&lt;0.001</td>
</tr>
<tr>
<td valign="middle" rowspan="2" align="left">Trachea</td>
<td valign="middle" align="left">D<sub>max</sub>(Gy)</td>
<td valign="middle" align="center">5.12 &#xb1; 5.37 (0.03-23.16)</td>
<td valign="middle" align="center">5.20 &#xb1; 5.37 (0.03-23.77)</td>
<td valign="middle" align="center">0.13</td>
</tr>
<tr>
<td valign="middle" align="left">D<sub>4cc</sub>(Gy)</td>
<td valign="middle" align="center">3.11 &#xb1; 3.44 (0.01-13.81)</td>
<td valign="middle" align="center">3.06 &#xb1; 3.44 (0.02-13.95)</td>
<td valign="middle" align="center">0.25</td>
</tr>
<tr>
<td valign="middle" rowspan="6" align="left">Lung</td>
<td valign="middle" align="left">D<sub>1000cc</sub> (Gy)</td>
<td valign="middle" align="center">1.21 &#xb1; 0.66 (0.08-4.10)</td>
<td valign="middle" align="center">1.34 &#xb1; 0.93 (0.08-5.22)</td>
<td valign="middle" align="center">&lt;0.001</td>
</tr>
<tr>
<td valign="middle" align="left">D<sub>1500cc</sub> (Gy)</td>
<td valign="middle" align="center">0.51 &#xb1; 0.37 (0.05-2.44)</td>
<td valign="middle" align="center">0.55 &#xb1; 0.40 (0.05-2.70)</td>
<td valign="middle" align="center">&lt;0.001</td>
</tr>
<tr>
<td valign="middle" align="left">MLD(Gy)</td>
<td valign="middle" align="center">2.39 &#xb1; 0.78 (0.61-4.59)</td>
<td valign="middle" align="center">2.47 &#xb1; 0.80 (0.63-4.68)</td>
<td valign="middle" align="center">&lt;0.001</td>
</tr>
<tr>
<td valign="middle" align="left">V<sub>5</sub>(%)</td>
<td valign="middle" align="center">12.10 &#xb1; 3.89 (2.11-24.15)</td>
<td valign="middle" align="center">13.04 &#xb1; 3.90 (2.42-24.35)</td>
<td valign="middle" align="center">&lt;0.001</td>
</tr>
<tr>
<td valign="middle" align="left">V<sub>10</sub>(%)</td>
<td valign="middle" align="center">6.69 &#xb1; 2.47 (1.12-13.97)</td>
<td valign="middle" align="center">7.02 &#xb1; 2.42 (1.21-14.86)</td>
<td valign="middle" align="center">0.013</td>
</tr>
<tr>
<td valign="middle" align="left">V<sub>20</sub>(%)</td>
<td valign="middle" align="center">3.01 &#xb1; 1.39 (0.14-6.96)</td>
<td valign="middle" align="center">3.07 &#xb1; 1.35 (0.14-7.27)</td>
<td valign="middle" align="center">0.016</td>
</tr>
<tr>
<td valign="middle" align="left">Heart</td>
<td valign="middle" align="left">D<sub>1500cc</sub> (Gy)</td>
<td valign="middle" align="center">5.48 &#xb1; 5.0 (0.06-36.48)</td>
<td valign="middle" align="center">5.61 &#xb1; 5.05 (0.05-36.13)</td>
<td valign="middle" align="center">&lt;0.001</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
<sec id="s3_2">
<title>Dosimetric evaluation of OAR</title>
<p>All dosimetric parameters of the lung, esophagus, spinal cord and heart were significantly decreased in the VMAT<sub>FFF</sub> plan (<italic>p</italic>&lt;0.05). The absolute differences in D<sub>1000cc</sub>, D<sub>1500cc</sub>, MLD, V<sub>5</sub>, V<sub>10</sub>, and V<sub>20</sub>of the lung were up to 0.13 Gy, 0.04 Gy, 0.08 Gy, 0.94%, 0.33% and 0.06% higher, respectively, with the VMAT<sub>FF</sub> plan. Compared with the VMAT<sub>FF</sub> plan, the VMAT<sub>FFF</sub> plan provided a lower D<sub>max</sub>, D<sub>0.25cc</sub> and D<sub>0.5cc</sub> to the spinal cord, D<sub>max</sub> and D<sub>5cc</sub> to the esophagus, and D<sub>1500cc</sub> to the heart by 0.15 Gy, 0.21 Gy, 0.23 Gy, 0.13 Gy, 0.1 Gy and 0.13 Gy, respectively. No substantial differences were observed in D<sub>max</sub> and D<sub>4cc</sub> of the trachea (<italic>p</italic>&gt;0.05). <xref ref-type="fig" rid="f2">
<bold>Figure&#xa0;2</bold>
</xref> shows the V<sub>5</sub>, V<sub>10</sub>, V<sub>20</sub> and MLD of the lung for FFF beams and FF beams for all treatment plans, and the metrics are represented as a function of the PTV volume.</p>
<fig id="f2" position="float">
<label>Figure&#xa0;2</label>
<caption>
<p>Lung representative dosimetric parameters for FFF beams and FF beams. <bold>(A)</bold>V<sub>5</sub> of lung. <bold>(B)</bold>V<sub>10</sub> of lung.<bold>(C)</bold> V<sub>20</sub> of lung. <bold>(D)</bold> MLD of lung.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fonc-13-1108142-g002.tif"/>
</fig>
<p>
<xref ref-type="fig" rid="f3">
<bold>Figure&#xa0;3</bold>
</xref> and <xref ref-type="fig" rid="f4">
<bold>Figure&#xa0;4</bold>
</xref> show the DVHs and a dose distribution in one patient, respectively. As can be seen in <xref ref-type="fig" rid="f1">
<bold>Figure&#xa0;1</bold>
</xref>, for the PTV, the high-dose spillage of the VMAT<sub>FFF</sub> plan was significantly lower than the VMAT<sub>FF</sub> plan; for the OAR, the VMAT<sub>FFF</sub> plan significantly reduced low-dose spillage for the lung and spinal cord. In <xref ref-type="fig" rid="f3">
<bold>Figure&#xa0;3</bold>
</xref>, the VMAT<sub>FFF</sub> plan had the slight advantages of providing tighter intermediate-dose spillage (see R<sub>50%</sub> and GI) compared with the VMAT<sub>FF</sub> plan.</p>
<fig id="f3" position="float">
<label>Figure&#xa0;3</label>
<caption>
<p>Dose-volume histogram of target and selected OARs. (Solid line: VMAT<sub>FFF</sub>, Dashed line: VMAT<sub>FF</sub>). <bold>(A)</bold> dose ranges from 0 to 61 Gy. <bold>(B)</bold> dose ranges from 0 to 20 Gy.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fonc-13-1108142-g003.tif"/>
</fig>
<fig id="f4" position="float">
<label>Figure&#xa0;4</label>
<caption>
<p>Comparison of dose distributions for a patient with contoured PTV (red), lung (light green), heart (brown), esophagus (cyan), and trachea (dark cyan). <bold>(A)</bold> VMAT<sub>FFF</sub> plan. <bold>(B)</bold> VMAT<sub>FF</sub> plan. The dose distribution ranges from 25 Gy to 65 Gy. <bold>(C)</bold> The absolute dose difference distribution between the <bold>(A)</bold> and <bold>(B)</bold>. The dose distribution ranges from -3.11 Gy (blue color) to 3.11 Gy (red color).</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fonc-13-1108142-g004.tif"/>
</fig>
</sec>
<sec id="s3_3">
<title>NTCP evaluation of the lung</title>
<p><xref ref-type="table" rid="T5"><bold>Table&#xa0;5</bold>
</xref> lists the NTCP values for the VMAT<sub>FFF</sub> plan and the VMAT<sub>FF</sub> plan. According to the NTCP model based on MLD, the average values [range] were 1.86 &#xb1; 0.19% [1.58%-5.71%] and 1.88 &#xb1; 0.19% [1.58%-5.82%] for the VMAT<sub>FFF</sub> plan and VMAT<sub>FF</sub> plan, respectively. For the model based on V<sub>5</sub>, the average NTCP [range] value for the VMAT<sub>FFF</sub> plan was 3.87 &#xb1; 1.73% [1.74%-9.01%] compared with 4.17 &#xb1; 1.80% [1.83%-9.51%] for the VMAT<sub>FF</sub> plan. The NTCP based on V<sub>20</sub> were 3.31 &#xb1; 0.70% [2.28%-5.37%] and 3.33 &#xb1; 0.73% [2.28%-5.59%] for the VMAT<sub>FFF</sub> plan and the VMAT<sub>FF</sub> plan, respectively.</p>
<table-wrap id="T5" position="float">
<label>Table&#xa0;5</label>
<caption>
<p>Comparison of NTCP (mean &#xb1; standard)of lung.</p>
</caption>
<table frame="hsides">
<thead>
<tr>
<th valign="middle" align="left">Parameters</th>
<th valign="middle" align="center">VMAT<sub>FFF</sub> (range)</th>
<th valign="middle" align="center">VMAT<sub>FF</sub> (range)</th>
<th valign="middle" align="center">
<italic>p</italic>
</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="middle" align="left">MLD (%)</td>
<td valign="middle" align="center">1.86 &#xb1; 0.19 (1.58-15.87)</td>
<td valign="middle" align="center">1.88 &#xb1; 0.19 (1.58-16.35)</td>
<td valign="middle" align="center">&lt;0.001</td>
</tr>
<tr>
<td valign="middle" align="left">V<sub>5</sub> (%)</td>
<td valign="middle" align="center">3.87 &#xb1; 1.73 (1.74-9.01)</td>
<td valign="middle" align="center">4.17 &#xb1; 1.80 (1.83-9.51)</td>
<td valign="middle" align="center">&lt;0.001</td>
</tr>
<tr>
<td valign="middle" align="left">V<sub>20</sub> (%)</td>
<td valign="middle" align="center">3.31 &#xb1; 0.70 (2.28-5.37)</td>
<td valign="middle" align="center">3.33 &#xb1; 0.73 (2.28-5.59)</td>
<td valign="middle" align="center">&lt;0.001</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
<sec id="s3_4">
<title>MUs, beam on-time and treatment time</title>
<p>The average MU values were 1871 &#xb1; 278 MUs and 1890 &#xb1; 260 MUs for the VMAT<sub>FFF</sub> plan and the VMAT<sub>FF</sub> plan, respectively. The average beam on-time was 1.3 times higher for the VMAT<sub>FF</sub> plan: 4.2 &#xb1; 0.3&#xa0;min, while for the VMAT<sub>FFF</sub> plan, due to the higher dose rates, the beam on-time reduced to 3.2 &#xb1; 0.2&#xa0;min. The average treatment time were 3.9 &#xb1; 0.3&#xa0;min and 4.8 &#xb1; 0.4&#xa0;min for the VMAT<sub>FFF</sub> plan and the VMAT<sub>FF</sub> plan, respectively.</p>
</sec>
<sec id="s3_5">
<title>A volume-based analysis</title>
<p>Patient&#x2019;s PTVs ranges from 5.07 to 33.49 cc were stratified into four volume groups according to the RTOG 0813 protocol. All values for PTV (R<sub>50%</sub> and GI), the lung (V<sub>5</sub>, V<sub>10</sub>, V<sub>20</sub> and MLD) and the NTCP of the lung in the four groups are provided in <xref ref-type="table" rid="T6">
<bold>Table&#xa0;6</bold>
</xref>. The results for the heart, esophagus, trachea and spinal cord are not listed since these OARs were not close to the PTV and do not show a clear trend with the PTV. For all groups, the data showed significant differences between the VMAT<sub>FFF</sub> plan and the VMAT<sub>FF</sub> plan (<italic>p</italic>&lt;0.05).</p>
<table-wrap id="T6" position="float">
<label>Table&#xa0;6</label>
<caption>
<p>Summary of the results for parameters of PTV, lung and NTCP (mean &#xb1; standard)in four group according to the PTV volume.</p>
</caption>
<table frame="hsides">
<thead>
<tr>
<th valign="middle" align="left"/>
<th valign="middle" colspan="2" align="center">Parameters</th>
<th valign="middle" align="center">Group&#xa0;1 (range)</th>
<th valign="middle" align="center">Group&#xa0;2 (range)</th>
<th valign="middle" align="center">Group&#xa0;3 (range)</th>
<th valign="middle" align="center">Group&#xa0;4 (range)</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="middle" rowspan="4" align="left">PTV</td>
<td valign="middle" rowspan="2" align="center">R<sub>50%</sub>
</td>
<td valign="middle" align="center">VMAT<sub>FFF</sub>
</td>
<td valign="middle" align="center">5.59 &#xb1; 0.40 (5.11-6.23)</td>
<td valign="middle" align="center">5.11 &#xb1; 0.62 (4.11-6.72)</td>
<td valign="middle" align="center">4.75 &#xb1; 0.43 (3.55-5.7)</td>
<td valign="middle" align="center">4.13 &#xb1; 0.47 (3.29-5.19)</td>
</tr>
<tr>
<td valign="middle" align="center">VMAT<sub>FF</sub>
</td>
<td valign="middle" align="center">5.80 &#xb1; 0.45 (5.23-6.42)</td>
<td valign="middle" align="center">5.23 &#xb1; 0.63 (4.12-6.88)</td>
<td valign="middle" align="center">4.84 &#xb1; 0.46 (3.55-5.79)</td>
<td valign="middle" align="center">4.21 &#xb1; 0.49 (3.37-5.44)</td>
</tr>
<tr>
<td valign="middle" rowspan="2" align="center">GI</td>
<td valign="middle" align="center">VMAT<sub>FFF</sub>
</td>
<td valign="middle" align="center">6.09 &#xb1; 0.37 (5.35-6.64)</td>
<td valign="middle" align="center">5.45 &#xb1; 0.72 (4.23-6.49)</td>
<td valign="middle" align="center">5.06 &#xb1; 0.64 (3.52-6.57)</td>
<td valign="middle" align="center">4.53 &#xb1; 0.51 (3.61-5.69)</td>
</tr>
<tr>
<td valign="middle" align="center">VMAT<sub>FF</sub>
</td>
<td valign="middle" align="center">6.31 &#xb1; 0.37 (5.49-6.68)</td>
<td valign="middle" align="center">5.58 &#xb1; 0.75 (4.28-6.83)</td>
<td valign="middle" align="center">5.16 &#xb1; 0.67 (3.55-6.91)</td>
<td valign="middle" align="center">4.60 &#xb1; 0.59 (3.66-6.61)</td>
</tr>
<tr>
<td valign="middle" rowspan="8" align="left">Lung</td>
<td valign="middle" rowspan="2" align="center">V<sub>5</sub>(%)</td>
<td valign="middle" align="center">VMAT<sub>FFF</sub>
</td>
<td valign="middle" align="center">7.55 &#xb1; 2.23 (5.11-11.05)</td>
<td valign="middle" align="center">10.86 &#xb1; 3.63 (2.11-19.23)</td>
<td valign="middle" align="center">12.95 &#xb1; 3.19 (5.14-24.15)</td>
<td valign="middle" align="center">15.03 &#xb1; 4.46 (4.12-21.22)</td>
</tr>
<tr>
<td valign="middle" align="center">VMAT<sub>FF</sub>
</td>
<td valign="middle" align="center">8.35 &#xb1; 2.25 (5.42-11.52)</td>
<td valign="middle" align="center">11.94 &#xb1; 3.61 (2.42-19.71)</td>
<td valign="middle" align="center">13.63 &#xb1; 3.14 (6.23-24.35)</td>
<td valign="middle" align="center">17.02 &#xb1; 5.09 (5.15-24.12)</td>
</tr>
<tr>
<td valign="middle" rowspan="2" align="center">V<sub>10</sub>(%)</td>
<td valign="middle" align="center">VMAT<sub>FFF</sub>
</td>
<td valign="middle" align="center">3.71 &#xb1; 1.67 (1.12-7.12)</td>
<td valign="middle" align="center">5.43 &#xb1; 2.90 (1.50-10.41)</td>
<td valign="middle" align="center">6.65 &#xb1; 2.26 (3.61-13.04)</td>
<td valign="middle" align="center">7.84 &#xb1; 2.83 (2.10-13.97)</td>
</tr>
<tr>
<td valign="middle" align="center">VMAT<sub>FF</sub>
</td>
<td valign="middle" align="center">4.04 &#xb1; 1.63 (1.21-7.23)</td>
<td valign="middle" align="center">5.76 &#xb1; 2.98 (1.66-11.14)</td>
<td valign="middle" align="center">7.07 &#xb1; 2.26 (3.32-13.44)</td>
<td valign="middle" align="center">8.58 &#xb1; 2.80 (2.85-14.86)</td>
</tr>
<tr>
<td valign="middle" rowspan="2" align="center">V<sub>20</sub>(%)</td>
<td valign="middle" align="center">VMAT<sub>FFF</sub>
</td>
<td valign="middle" align="center">1.73 &#xb1; 0.80 (1.12-3.38)</td>
<td valign="middle" align="center">2.33 &#xb1; 1.05 (0.14-5.18)</td>
<td valign="middle" align="center">3.48 &#xb1; 1.15 (1.49-6.34)</td>
<td valign="middle" align="center">4.38 &#xb1; 1.63 (1.59-6.96)</td>
</tr>
<tr>
<td valign="middle" align="center">VMAT<sub>FF</sub>
</td>
<td valign="middle" align="center">1.79 &#xb1; 0.80 (1.19-3.43)</td>
<td valign="middle" align="center">2.38 &#xb1; 1.07 (0.14-5.18)</td>
<td valign="middle" align="center">3.52 &#xb1; 1.17 (1.50-6.74)</td>
<td valign="middle" align="center">4.56 &#xb1; 1.72 (1.59-7.27)</td>
</tr>
<tr>
<td valign="middle" rowspan="2" align="center">MLD(Gy)</td>
<td valign="middle" align="center">VMAT<sub>FFF</sub>
</td>
<td valign="middle" align="center">1.60 &#xb1; 0.55 (0.61-2.42)</td>
<td valign="middle" align="center">2.19 &#xb1; 0.82 (0.61-3.23)</td>
<td valign="middle" align="center">2.53 &#xb1; 0.66 (1.15-4.59)</td>
<td valign="middle" align="center">2.98 &#xb1; 0.77 (0.99-4.33)</td>
</tr>
<tr>
<td valign="middle" align="center">VMAT<sub>FF</sub>
</td>
<td valign="middle" align="center">1.66 &#xb1; 0.57 (0.63-2.52)</td>
<td valign="middle" align="center">2.25 &#xb1; 0.83 (0.63-3.27)</td>
<td valign="middle" align="center">2.61 &#xb1; 0.66 (1.16-4.68)</td>
<td valign="middle" align="center">3.09 &#xb1; 0.77 (1.05-4.47)</td>
</tr>
<tr>
<td valign="middle" rowspan="6" align="left">NTCP</td>
<td valign="middle" rowspan="2" align="center">MLD (%)</td>
<td valign="middle" align="center">VMAT<sub>FFF</sub>
</td>
<td valign="middle" align="center">1.86 &#xb1; 0.84<break/>(1.79-2.74)</td>
<td valign="middle" align="center">2.44 &#xb1; 0.27 (1.58-15.87)</td>
<td valign="middle" align="center">2.91 &#xb1; 0.67 (1.83-5.71)</td>
<td valign="middle" align="center">3.38 &#xb1; 0.82<break/>(1.74-5.16)</td>
</tr>
<tr>
<td valign="middle" align="center">VMAT<sub>FF</sub>
</td>
<td valign="middle" align="center">1.88 &#xb1; 0.85 (1.79-2.75)</td>
<td valign="middle" align="center">2.50 &#xb1; 0.27 (1.58-16.35)</td>
<td valign="middle" align="center">2.99 &#xb1; 0.67 (1.83-5.82)</td>
<td valign="middle" align="center">3.53 &#xb1; 0.87<break/>(1.79-5.48)</td>
</tr>
<tr>
<td valign="middle" rowspan="2" align="center">V<sub>5</sub>(%)</td>
<td valign="middle" align="center">VMAT<sub>FFF</sub>
</td>
<td valign="middle" align="center">2.73 &#xb1; 0.50<break/>(2.22-3.51)</td>
<td valign="middle" align="center">3.72 &#xb1; 0.79 (1.74-5.37)</td>
<td valign="middle" align="center">3.95 &#xb1; 1.02 (2.44-9.01)</td>
<td valign="middle" align="center">4.66 &#xb1; 1.28<break/>(2.07-6.94)</td>
</tr>
<tr>
<td valign="middle" align="center">VMAT<sub>FF</sub>
</td>
<td valign="middle" align="center">2.92 &#xb1; 0.50<break/>(2.33-3.67)</td>
<td valign="middle" align="center">4.05 &#xb1; 0.69 (1.83-6.06)</td>
<td valign="middle" align="center">4.16 &#xb1; 1.04 (2.62-9.51)</td>
<td valign="middle" align="center">5.33 &#xb1; 1.69<break/>(2.28-8.38)</td>
</tr>
<tr>
<td valign="middle" rowspan="2" align="center">V<sub>20</sub>(%)</td>
<td valign="middle" align="center">VMAT<sub>FFF</sub>
</td>
<td valign="middle" align="center">2.92 &#xb1; 0.32 (2.68-3.59)</td>
<td valign="middle" align="center">3.11 &#xb1; 0.39 (2.28-8.85)</td>
<td valign="middle" align="center">3.43 &#xb1; 0.53 (2.68-4.75)</td>
<td valign="middle" align="center">3.76 &#xb1; 0.85<break/>(2.28-5.37)</td>
</tr>
<tr>
<td valign="middle" align="center">VMAT<sub>FF</sub>
</td>
<td valign="middle" align="center">2.93 &#xb1; 0.33<break/>(2.68-3.59)</td>
<td valign="middle" align="center">3.14 &#xb1; 0.38 (2.28-9.18)</td>
<td valign="middle" align="center">3.45 &#xb1; 0.55 (2.68-4.75)</td>
<td valign="middle" align="center">3.84 &#xb1; 0.91<break/>(2.28-5.59)</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn>
<p>p values&lt;0.05 for all parameters.</p>
</fn>
</table-wrap-foot>
</table-wrap>
<p>The TD was calculated as follows:</p>
<disp-formula>
<label>(5)</label>
<mml:math display="block" id="M6">
<mml:mrow>
<mml:mtext>TD</mml:mtext>
<mml:mo>=</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:msub>
<mml:mtext>V</mml:mtext>
<mml:mrow>
<mml:mtext>FF</mml:mtext>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mrow>
<mml:msub>
<mml:mtext>V</mml:mtext>
<mml:mrow>
<mml:mtext>FFF</mml:mtext>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:math>
</disp-formula>
<p>where V<sub>FF</sub> and V<sub>FFF</sub> represent the values for the VMAT<sub>FF</sub> and VMAT<sub>FFF</sub> plans, respectively. The GI and R<sub>50%</sub> values show a decrease between Group 1 and Group 2 which is then stable in Group 3 and 4with increasing volumes. The VMAT<sub>FFF</sub> plan can be observed as the most advantageous for a small volume in terms of R<sub>50%</sub> and GI. In Group 1, the TD values for R<sub>50%</sub> had a mean value of 1.04, while this value for GI was 1.04. In <xref ref-type="fig" rid="f5">
<bold>Figure&#xa0;5B</bold>
</xref>, the trend observed was different to that of the GI and the fluctuations were more marked. For V<sub>5</sub>, V<sub>10</sub>, V<sub>20</sub> and the MLD of lung, the biggest differences between the two plans were in Group 4, at 1.13, 1.09, 1.04 and 1.04, respectively. In <xref ref-type="fig" rid="f5">
<bold>Figure&#xa0;5C</bold>
</xref>, the trend observed was similar to that of <xref ref-type="fig" rid="f5">
<bold>Figure&#xa0;5B</bold>
</xref> and the biggest difference between the two plans appeared in Group 4.</p>
<fig id="f5" position="float">
<label>Figure&#xa0;5</label>
<caption>
<p>
<bold>(A&#x2013;C)</bold> presents the difference (TD) between two plans for the PTV, lung and NTCP, respectively.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fonc-13-1108142-g005.tif"/>
</fig>
<p>Furthermore, R<sub>50%</sub> for the VMAT<sub>FFF</sub> plan and the VMAT<sub>FF</sub> plan are described with a power functional form and shown in Eq.(6) and Eq.(7):</p>
<disp-formula>
<label>(6)</label>
<mml:math display="block" id="M7">
<mml:mrow>
<mml:msub>
<mml:mi>R</mml:mi>
<mml:mrow>
<mml:mn>50</mml:mn>
<mml:mo>%</mml:mo>
<mml:mi>F</mml:mi>
<mml:mi>F</mml:mi>
<mml:mi>F</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>=</mml:mo>
<mml:mn>7.72</mml:mn>
<mml:msup>
<mml:mi>V</mml:mi>
<mml:mrow>
<mml:mo>&#x2212;</mml:mo>
<mml:mn>0.19</mml:mn>
</mml:mrow>
</mml:msup>
</mml:mrow>
</mml:math>
</disp-formula>
<p>where V is the volume of PTV, with a standard error of 0.36 and 0.02 for the A and B parameters, and an R<sup>2</sup> of 0.4;</p>
<disp-formula>
<label>(7)</label>
<mml:math display="block" id="M8">
<mml:mrow>
<mml:msub>
<mml:mi>R</mml:mi>
<mml:mrow>
<mml:mn>50</mml:mn>
<mml:mo>%</mml:mo>
<mml:mi>F</mml:mi>
<mml:mi>F</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>=</mml:mo>
<mml:mn>7.92</mml:mn>
<mml:msup>
<mml:mi>V</mml:mi>
<mml:mrow>
<mml:mo>&#x2212;</mml:mo>
<mml:mn>0.2</mml:mn>
</mml:mrow>
</mml:msup>
</mml:mrow>
</mml:math>
</disp-formula>
<p>with an R<sup>2</sup> of 0.4, and a standard error of 0.38 and 0.02 for the A and B parameters. A plot of R<sub>50%</sub> versus PTV is presented in <xref ref-type="fig" rid="f6">
<bold>Figure&#xa0;6</bold>
</xref>. <xref ref-type="fig" rid="f6">
<bold>Figure&#xa0;6</bold>
</xref> shows that VMAT<sub>FFF</sub> plan have steeply dose fall-off than VMAT<sub>FF</sub> plans. According to the RTOG 0813/0915 reports, 195 plans exhibited no deviation, 3 plans a minor deviation (less than 10% difference), and none exhibited a major deviation (more than 10% difference) for the VMAT<sub>FFF</sub> plan; 186 plans exhibited no deviation, 12 plans a minor deviation, and none exhibited a major deviation for the VMAT<sub>FF</sub> plan.</p>
<fig id="f6" position="float">
<label>Figure&#xa0;6</label>
<caption>
<p>The R<sub>50%</sub> for VMAT<sub>FFF</sub> and VMAT<sub>FF</sub> plans plotted with PTV volume and was presented by a power functional form: <bold>(A)</bold> R<sub>50%</sub> of VMAT<sub>FFF</sub> plan. <bold>(B)</bold> R<sub>50%</sub> of VMAT<sub>FF</sub> plan.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fonc-13-1108142-g006.tif"/>
</fig>
<p>
<xref ref-type="fig" rid="f5">
<bold>Figure&#xa0;5</bold>
</xref> The differences between VMAT<sub>FFF</sub> and VMAT<sub>FF</sub> plans in four groups: <bold>(A)</bold> R<sub>50%</sub> and GI of PTV. <bold>(B)</bold> V<sub>5</sub>, V<sub>10</sub>, V<sub>20</sub> and MLD of lung. <bold>(C)</bold> NTCP of V<sub>5</sub>, V<sub>20</sub> and MLD.</p>
</sec>
</sec>
<sec id="s4" sec-type="discussion">
<title>Discussion</title>
<p>In the present study, for 175 patients with 198 pulmonary lesions, we investigated the potential advantage of using FFF beams in lung SBRT based on the target volumes. For the investigated VMAT techniques, treatment planning with FFF beams resulted in plans of similar or better quality and a lower NTCP of the lung compared with FF beams. Furthermore, our results indicated that the differences between FFF and FF beams for the parameters of PTV of the lung and the NTCP have been related to the target volume, as shown in <xref ref-type="table" rid="T6">
<bold>Table&#xa0;6</bold>
</xref> and <xref ref-type="fig" rid="f5">
<bold>Figure&#xa0;5</bold>
</xref>.</p>
<p>With large doses in a few fractions and a conventional dose rate, the SBRT beam on-time can become very long, increasing patient discomfort and treatment uncertainty. Hence, shortening the SBRT beam on-time becomes crucial. A primary advantage of FFF beams is that they have similar MUs; meanwhile, they shave a shortened beam on-time compared with FF beams. Our results showed that the FFF beams obtained a 23.8% reduction in beam on-time, a 18.8% reduction in treatment time and a 1.0% reduction in MUs for VMAT. A few investigators have reported the time advantage of FFF beams for VMAT plans. For instance, Pokhrel et&#xa0;al. (<xref ref-type="bibr" rid="B8">8</xref>) reported that the average beam on-time for FFF beams was 6.5&#xa0;min, and was much shorter than for FF beams (15.1&#xa0;min). Pokhrel et&#xa0;al. (<xref ref-type="bibr" rid="B15">15</xref>) has shown an overall reduction in beam on-time by about 57.0% using FFF beams for lung lesions. However, in our study, the beam on-time of FFF beams was not significantly reduced compared to the FF beams, which could be related to the DMPO algorithm (Pinnacle) generating segment having less MUs than others TPS. When the dose rate was still increasing, the segment was over. Furthermore, compared to the FF beams, the MUs did not change significantly while using FFF beams. Furthermore, the reason for similar MUs for FFF beams and FF beams is likely to be the small PTV in this study.</p>
<p>One of the major concerns for treating lung cancer using SBRT is the low-dose bath exposure of the lung, such as V<sub>5</sub>, V<sub>10</sub>, V<sub>20</sub> and the MLD (<xref ref-type="bibr" rid="B29">29</xref>). According to the RTOG 0813 recommendation (<xref ref-type="bibr" rid="B18">18</xref>), all of the SBRT plans had D<sub>1500cc</sub>&lt;12.5 Gy, D<sub>1000cc</sub>&lt;13.5 Gy and V<sub>20</sub>&lt;10%. The use of FFF beams in lung SBRT treatment has been previously studied (<xref ref-type="bibr" rid="B6">6</xref>, <xref ref-type="bibr" rid="B15">15</xref>, <xref ref-type="bibr" rid="B30">30</xref>). Pokhrel et&#xa0;al. (<xref ref-type="bibr" rid="B15">15</xref>) designed VMAT plans using FFF beams and FF beams for 13 patients with lung cancer. They found that the VMAT<sub>FFF</sub> plans had a lower dose to OAR. Similarly, Vassiliev et&#xa0;al. (<xref ref-type="bibr" rid="B30">30</xref>) investigated dosimetric differences between FFF beams and FF beams, and reported that FFF beams achieved significantly better target coverage and OAR-sparing than FF beams. This dosimetric advantage of FFF beams was due to the lower out-of-field dose, more rapid dose fall-off, and softer energy spectrum removing the flattening filter compared to FF beams (<xref ref-type="bibr" rid="B31">31</xref>). In the current study, utilizing FFF beams for VMAT plans resulted in a better D<sub>2</sub> and falloff gradient (R<sub>50%</sub> and GI) and achieved a similar target coverage (D<sub>90</sub>, CR, and CI) compared to FF beam plans. The differences in the D<sub>90</sub>, CR, and CI were not significant. For all plans, the VMAT<sub>FFF</sub> plans provided similar or better OAR-sparing (lung, esophagus, spinal cord and heart), except the trachea. V<sub>5</sub>, V<sub>10</sub>, and V<sub>20</sub> of lung were found to be lower by an average of 0.94%, 0.33%, and 0.06% for FFF beams compared with FF beams, respectively. Although, FFF beams has significantly better OAR-sparing than FF beams, the absolute differences between the values are very small. This result might due to the small target volume in our study, the mean volume of PTV is 14.63 &#xb1; 5.25 cc. With the target volume increase, the absolute difference between FFF beams and FF beams will increase. For instance, V<sub>5</sub>, V<sub>10</sub>, and V<sub>20</sub> of lung were lower by an average of 1.99%, 0.74%, and 0.18% for FFF beams compared with FF beams in Group4, respectively.</p>
<p>For the lung, FFF beams appeared the most advantageous for a large-size target (Group 4) in V<sub>5</sub>, V<sub>10</sub>, V<sub>20</sub> and the MLD of lung. Although the fluctuations were more marked, the trend in the differences increased with an increasing target volume. A different trend was observed for R<sub>50%</sub> and GI; the biggest differences between two techniques appeared in Group 1: 3.62% for R<sub>50%</sub> and 3.49% for GI, respectively. There may be several possible explanations for these trends, including (<xref ref-type="bibr" rid="B1">1</xref>) there was no significant difference in D<sub>90</sub>, CR, and the CI of PTV between the two techniques due to the profile of the FFF and FFF beams, which are similar; the difference is a lower penumbra, as described by Hrbacek et&#xa0;al. (<xref ref-type="bibr" rid="B31">31</xref>) (<xref ref-type="bibr" rid="B2">2</xref>); FFF beams have a reduced out-of-field dose that is lower than that for FF beams, especially at the edge of the field and at distances further from the edge; thus, there is a noticeable reduction effect for low doses, such as V<sub>5</sub> of the lung.</p>
<p>Previous studies have indicated that the dose difference can be significant for radiobiological factors of NTCP (<xref ref-type="bibr" rid="B32">32</xref>), which could affect radiotherapy quality. Therefore, evaluating NTCP is a very important part of a comparative study of the two technologies. Timmeren et&#xa0;al. (<xref ref-type="bibr" rid="B33">33</xref>) compared a multiple-isocenter technique and a single-isocenter technique for lung SBRT with NTCP based on MLD and V<sub>20</sub>. Kang et&#xa0;al. (<xref ref-type="bibr" rid="B34">34</xref>) evaluated the dosimetric and radiobiological parameters in four radiotherapy regimens for synchronous bilateral breast cancer. However, to our knowledge, there are fewer related studies on FFF beams in lung SBRT. Lower doses to the lung of FFF beams resulted in a significantly lower NTCP based on the MLD, V<sub>5</sub> and V<sub>20</sub>. Evaluated by an NTCP model based on the MLD developed by Borst et&#xa0;al. (<xref ref-type="bibr" rid="B26">26</xref>), the risk of radiation pneumonitis decreased, on average, by 0.02% using FFF beams compared to FF beams; this was 0.3% to the model based on V<sub>5</sub> and 0.02% to the model based on V<sub>20</sub>. We found that lung SBRT with FFF beams could be safely used in order to improve the plan quality and reduce beam on-time. As a result, it is expected that a lower incidence of pneumonitis would be responsible for lung toxicity in lung SBRT patients using FFF beams.</p>
<p>Additionally, we assessed the equations to predict the R<sub>50%</sub> with a small PTV (&lt;34 cm<sup>3</sup>). Of the 198 lung SBRT plans, 3 exhibited a minor deviation for the VMAT<sub>FFF</sub> plans and 12 exhibited a minor deviation for the VMAT<sub>FF</sub> plans, respectively, and none exhibited a major deviation according to the RTOG 0813/0915 reports. It is also worth highlighting that FFF beams have better dose fall-off than FF beams. Hoffman et&#xa0;al. (<xref ref-type="bibr" rid="B35">35</xref>) provided the equation of R<sub>50%</sub> for 317 lung SBRT plans, and the PTV range was from 1.8 cm<sup>3</sup> to 163 cm<sup>3</sup>. Our equation was larger than Hoffman&#x2019;s work, which may be due to the values of R<sub>50%</sub> in our work having a major deviation compared with the equation. The predictive capability of R<sub>50%</sub> equations for FFF beams and FF beams could function as a useful tool to guide a treatment planner before and after optimization. It can be time-consuming for a planner to generate VMAT plans, and they are often required to generate additional structures such as dose-limiting ring structures. Prior to optimization, the planner could approximately predict the dose distribution of the plan through the R<sub>50%</sub> equation, and the ring could be generated more accurately, which would reduce the plan optimization time. After optimization, the R<sub>50%</sub> equation could evaluate the value of R<sub>50%</sub> with no deviation, minor deviation, or major deviation, and potentially improve the plan quality. As part of the plan quality control (QC), the planner could benchmark the plan against R<sub>50%</sub> from the equation. Knowing a deviation of R<sub>50%</sub> compared with the equation, the planner could potentially be spared their efforts in pursuing a better outcome.</p>
<p>However, a limitation of our study was that we only studied a total of 7 and 17 lesions for Group 1 and Group 4, respectively. Future studies are needed to compare the two techniques for more lesions and to increase the PTV range from 34 cc to 95 cc or larger. Moreover, we only selected patients with lung cancer, but the potential for the target and OAR using FFF beams might be suitable for brain and liver SBRT cases. The clinical advantages of FFF beams should be also studied in other tumor cases based on the PTV. Another limitation is that we don&#x2019;t investigate the interplay effects between the tumor respiratory and dynamic MLC movement for FFF beams and FF beams. The interplay effects plays an important role and could create cold or hot spots inside the lung tumor (<xref ref-type="bibr" rid="B36">36</xref>, <xref ref-type="bibr" rid="B37">37</xref>). Fernandez et&#xa0;al. (<xref ref-type="bibr" rid="B36">36</xref>) investigated interplay effects in SBRT lung cases and concluded that the interplay effects could result in up to 20% dose variation near the edges of the PTV. However, it has been indicated that the interplay effects causes might negligible dose blurring when using two or more VMAT arcs for FFF beams (<xref ref-type="bibr" rid="B38">38</xref>). In the future, one could expand the investigation of interplay effects.</p>
<p>FFF beams and FF beams showed significant differences in dosimetric and radiobiological parameters. For the parameters of the lung, the biggest difference was observed between FFF beams and FF beams for a large target volume; the opposite was observed for the PTV parameter. In this retrospective analysis, we demonstrated that using FFF beams for lung SBRT can reduce the dose to OAR (except the trachea) and potentially provide faster treatment delivery by significantly reducing the beam on-time, when compared with FF beams. Furthermore, using FFF beams could improve patient&#x2019;s comfort, reduce intra-fraction motion and reduce the probability of radiation pneumonitis. The advantage of FFF beams could be observed with an increasing volume range from 3.8 cm<sup>3</sup> to 34 cm<sup>3</sup>.</p>
</sec>
<sec id="s5" sec-type="data-availability">
<title>Data availability statement</title>
<p>The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.</p>
</sec>
<sec id="s6" sec-type="author-contributions">
<title>Author contributions</title>
<p>Design of the research: JL, FW. Treatment plans: HS. Statistical Analysis: JW, JL. Manuscript preparation: HS, JW. Manuscript writing: HS, JW. Manuscript final revision: BT. All authors contributed to the article and approved the submitted version.</p>
</sec>
</body>
<back>
<sec id="s7" sec-type="funding-information">
<title>Funding</title>
<p>This study was supported by Sichuan Science and Technology Program (No. 2022YFS0047, No. 2021YFG0168, No. 2021YFG0320) and Medical Engineering Innovation Fund for Cancer (No. ZYGX2021YGCX002).</p>
</sec>
<sec id="s8" sec-type="COI-statement">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec id="s9" sec-type="disclaimer">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ref-list>
<title>References</title>
<ref id="B1">
<label>1</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zheng</surname> <given-names>RS</given-names>
</name>
<name>
<surname>Zhang</surname> <given-names>SW</given-names>
</name>
<name>
<surname>Zeng</surname> <given-names>HM</given-names>
</name>
<name>
<surname>Wang</surname> <given-names>SM</given-names>
</name>
<name>
<surname>Sun</surname> <given-names>K</given-names>
</name>
<name>
<surname>Chen</surname> <given-names>R</given-names>
</name>
<etal/>
</person-group>. <article-title>Cancer incidence and mortality in China, 2016</article-title>. <source>J Natl Cancer center</source> (<year>2022</year>) <volume>2</volume>(<issue>1</issue>):<fpage>1</fpage>&#x2013;<lpage>9</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.jncc.2022.02.002</pub-id>
</citation>
</ref>
<ref id="B2">
<label>2</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Guckenberger</surname> <given-names>M</given-names>
</name>
<name>
<surname>Andrastschke</surname> <given-names>N</given-names>
</name>
<name>
<surname>Dieckmann</surname> <given-names>K</given-names>
</name>
<name>
<surname>Hoogeman</surname> <given-names>MS</given-names>
</name>
<name>
<surname>Hoyer</surname> <given-names>M</given-names>
</name>
<name>
<surname>Hurkmans</surname> <given-names>C</given-names>
</name>
<etal/>
</person-group>. <article-title>ESTRO ACROP consensus guideline on implementation and practice of stereotactic body radiotherapy for peripherally located early stage non-small cell lung cancer</article-title>. <source>Radiother Oncol</source> (<year>2017</year>) <volume>124</volume>(<issue>1</issue>):<page-range>11&#x2013;7</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.radonc.2017.05.012</pub-id>
</citation>
</ref>
<ref id="B3">
<label>3</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Postmus</surname> <given-names>PE</given-names>
</name>
<name>
<surname>Kerr</surname> <given-names>KM</given-names>
</name>
<name>
<surname>Oudkerk</surname> <given-names>M</given-names>
</name>
<name>
<surname>Senan</surname> <given-names>S</given-names>
</name>
<name>
<surname>Waller</surname> <given-names>DA</given-names>
</name>
<name>
<surname>Vansteenkiste</surname> <given-names>J</given-names>
</name>
<etal/>
</person-group>. <article-title>Early and locally advanced non-small-cell lung cancer (NSCLC): ESMO ClinicalPractice guidelines for diagnosis, treatment and follow-up</article-title>. <source>Ann Oncol</source> (<year>2017</year>) <volume>28</volume>(<issue>4</issue>):<fpage>iv1</fpage>&#x2013;<lpage>iv21</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1093/annonc/mdt241</pub-id>
</citation>
</ref>
<ref id="B4">
<label>4</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Roeber</surname> <given-names>JH</given-names>
</name>
<name>
<surname>Bernhardt</surname> <given-names>D</given-names>
</name>
<name>
<surname>Blanck</surname> <given-names>O</given-names>
</name>
<name>
<surname>Duma</surname> <given-names>M</given-names>
</name>
<name>
<surname>Guckenberger</surname> <given-names>M</given-names>
</name>
</person-group>. <article-title>Long-term follow-up and patterns of recurrence of patients with oligometastatic NSCLCTreated with pulmonary SBRT</article-title>. <source>Clin Lung Cancer</source> (<year>2019</year>) <volume>20</volume>(<issue>6</issue>):<page-range>e667&#x2013;77</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.cllc.2019.06.024</pub-id>
</citation>
</ref>
<ref id="B5">
<label>5</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Benedict</surname> <given-names>S</given-names>
</name>
<name>
<surname>Yenice</surname> <given-names>K</given-names>
</name>
<name>
<surname>Followill</surname> <given-names>D</given-names>
</name>
<name>
<surname>Galvin</surname> <given-names>JM</given-names>
</name>
<name>
<surname>Hinson</surname> <given-names>W</given-names>
</name>
<name>
<surname>Kavangh</surname> <given-names>B</given-names>
</name>
<etal/>
</person-group>. <article-title>Stereotactic body radiation therapy: The report of AAPM task group 101</article-title>. <source>Med Phys</source> (<year>2010</year>) <volume>37</volume>(<issue>8</issue>):<page-range>4078&#x2013;100</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1118/1.3438081</pub-id>
</citation>
</ref>
<ref id="B6">
<label>6</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zimmermann</surname> <given-names>F</given-names>
</name>
<name>
<surname>Geinitz</surname> <given-names>H</given-names>
</name>
<name>
<surname>Schill</surname> <given-names>S</given-names>
</name>
<name>
<surname>Grosu</surname> <given-names>A</given-names>
</name>
<name>
<surname>Schratzenstaller</surname> <given-names>U</given-names>
</name>
<name>
<surname>Molls</surname> <given-names>M</given-names>
</name>
<etal/>
</person-group>. <article-title>Stereotactic hypofractionated radiation therapy for stage I non-small cell lung cancer</article-title>. <source>Lung Cancer</source> (<year>2005</year>) <volume>48</volume>(<issue>1</issue>):<page-range>107&#x2013;14</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.lungcan.2004.10.015</pub-id>
</citation>
</ref>
<ref id="B7">
<label>7</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Al-Hallaq</surname> <given-names>HA</given-names>
</name>
<name>
<surname>Chmura</surname> <given-names>S</given-names>
</name>
<name>
<surname>Salama</surname> <given-names>JK</given-names>
</name>
<name>
<surname>Winter</surname> <given-names>KA</given-names>
</name>
<name>
<surname>Robinson</surname> <given-names>CG</given-names>
</name>
<name>
<surname>Pisansky</surname> <given-names>TM</given-names>
</name>
<etal/>
</person-group>. <article-title>Rational of technical requirements for NRG-BR001: The first NCI-sponsored trial of SBRT for the treatment of multiple metastases</article-title>. <source>Pract Radiat Oncol</source> (<year>2016</year>) <volume>6</volume>(<issue>6</issue>):<page-range>e291&#x2013;8</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.prro.2016.05.004</pub-id>
</citation>
</ref>
<ref id="B8">
<label>8</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pokhrel</surname> <given-names>D</given-names>
</name>
<name>
<surname>Snford</surname> <given-names>L</given-names>
</name>
<name>
<surname>Dhanireddy</surname> <given-names>B</given-names>
</name>
<name>
<surname>Molloy</surname> <given-names>J</given-names>
</name>
<name>
<surname>Randall</surname> <given-names>M</given-names>
</name>
<name>
<surname>McGarry</surname> <given-names>RC</given-names>
</name>
</person-group>. <article-title>Flattening filter free VMAT for a stereotactic,single-dose of 30 gy to lung lesion in a 15-min treatment slot</article-title>. <source>J Appl Clin Med Phys</source> (<year>2020</year>) <volume>21</volume>(<issue>4</issue>):<fpage>6</fpage>&#x2013;<lpage>12</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/acm2.12829</pub-id>
</citation>
</ref>
<ref id="B9">
<label>9</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pokhrel</surname> <given-names>D</given-names>
</name>
<name>
<surname>Visal</surname> <given-names>J</given-names>
</name>
<name>
<surname>Sanford</surname> <given-names>L</given-names>
</name>
</person-group>. <article-title>A novel and clinically useful dynamic conformal arc (DCA)-based VMAT planning technique for lung SBRT</article-title>. <source>J Appl Clin Med Phys</source> (<year>2020</year>) <volume>21</volume>(<issue>7</issue>):<fpage>29</fpage>&#x2013;<lpage>38</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/acm2.12878</pub-id>
</citation>
</ref>
<ref id="B10">
<label>10</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Murakami</surname> <given-names>Y</given-names>
</name>
<name>
<surname>Magome</surname> <given-names>T</given-names>
</name>
<name>
<surname>Matsubayashi</surname> <given-names>F</given-names>
</name>
<name>
<surname>Takahashi</surname> <given-names>R</given-names>
</name>
<name>
<surname>Arima</surname> <given-names>M</given-names>
</name>
<name>
<surname>Kamima</surname> <given-names>T</given-names>
</name>
<etal/>
</person-group>. <article-title>Evaluation of organ-at-risk dose reduction with jaw tracking technique in flattening filter-free beams in lung stereotactic body radiation therapy</article-title>. <source>Phys Med</source> (<year>2019</year>) <volume>61</volume>:<page-range>70&#x2013;6</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.ejmp.2019.04.018</pub-id>
</citation>
</ref>
<ref id="B11">
<label>11</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kragl</surname> <given-names>G</given-names>
</name>
<name>
<surname>Wetterstedt</surname> <given-names>S</given-names>
</name>
<name>
<surname>Kn&#xe4;usl</surname> <given-names>B</given-names>
</name>
<name>
<surname>Lind</surname> <given-names>M</given-names>
</name>
<name>
<surname>McCavana</surname> <given-names>P</given-names>
</name>
<name>
<surname>Kn&#xf6;&#xf6;s</surname> <given-names>T</given-names>
</name>
<etal/>
</person-group>. <article-title>Dosimetric characteristics of 6 and 10 MV unflattened photon beams</article-title>. <source>Radiother Oncol</source> (<year>2009</year>) <volume>93</volume>(<issue>1</issue>):<page-range>141&#x2013;6</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.radonc.2009.06.008</pub-id>
</citation>
</ref>
<ref id="B12">
<label>12</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kry</surname> <given-names>SF</given-names>
</name>
<name>
<surname>Vassiliev</surname> <given-names>ON</given-names>
</name>
<name>
<surname>Mohan</surname> <given-names>R</given-names>
</name>
</person-group>. <article-title>Out-of-field photon dose following removal of the flattening filter from a medical accelerator</article-title>. <source>Phys Med Biol</source> (<year>2010</year>) <volume>55</volume>(<issue>8</issue>):<page-range>2155&#x2013;66</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1088/0031-9155/55/8/003</pub-id>
</citation>
</ref>
<ref id="B13">
<label>13</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Aoki</surname> <given-names>S</given-names>
</name>
<name>
<surname>Yamashita</surname> <given-names>H</given-names>
</name>
<name>
<surname>Haga</surname> <given-names>A</given-names>
</name>
<name>
<surname>Nawa</surname> <given-names>K</given-names>
</name>
<name>
<surname>Imae</surname> <given-names>T</given-names>
</name>
<name>
<surname>Takahashi</surname> <given-names>W</given-names>
</name>
<etal/>
</person-group>. <article-title>Flattening filter-free technique in volumetric modulated arc therapy for lung stereotactic body radiotherapy: A clinical comparison with the flattening filter technique</article-title>. <source>Oncol Lett</source> (<year>2018</year>) <volume>15</volume>:<page-range>3928&#x2013;36</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.3892/ol.2018.7809</pub-id>
</citation>
</ref>
<ref id="B14">
<label>14</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hrbacek</surname> <given-names>J</given-names>
</name>
<name>
<surname>Lang</surname> <given-names>S</given-names>
</name>
<name>
<surname>Graydon</surname> <given-names>SN</given-names>
</name>
<name>
<surname>Kl&#xf6;ck</surname> <given-names>S</given-names>
</name>
<name>
<surname>Riesterer</surname> <given-names>O</given-names>
</name>
</person-group>. <article-title>Dosimetric comparison of flattened and unflattened beams for stereotactic ablative radiotherapy of stage I non-small cell lung cancer</article-title>. <source>Med Phys</source> (<year>2014</year>) <volume>41</volume>(<issue>3</issue>):<fpage>031709</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1118/1.4866231</pub-id>
</citation>
</ref>
<ref id="B15">
<label>15</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pokhrel</surname> <given-names>D</given-names>
</name>
<name>
<surname>Halfman</surname> <given-names>M</given-names>
</name>
<name>
<surname>Sanford</surname> <given-names>L</given-names>
</name>
</person-group>. <article-title>FFF-VMAT for SBRT of lung lesions: Improves dose coverage at tumor-lung interface compared to flattened beams</article-title>. <source>J Appl Clin Med Phys</source> (<year>2020</year>) <volume>21</volume>(<issue>1</issue>):<fpage>26</fpage>&#x2013;<lpage>35</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/acm2.12764</pub-id>
</citation>
</ref>
<ref id="B16">
<label>16</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tambe</surname> <given-names>NS</given-names>
</name>
<name>
<surname>Fryer</surname> <given-names>A</given-names>
</name>
<name>
<surname>Marsden</surname> <given-names>JE</given-names>
</name>
<name>
<surname>Moore</surname> <given-names>C</given-names>
</name>
<name>
<surname>Beavis</surname> <given-names>AW</given-names>
</name>
</person-group>. <article-title>Determination of clinically appropriate flattening filter free (FFF) energy using treatment plans and delivery measurements</article-title>. <source>BioMed Phys Eng Express</source> (<year>2016</year>) <volume>2</volume>(<issue>6</issue>):<elocation-id>65016</elocation-id>. doi:&#xa0;<pub-id pub-id-type="doi">10.1088/2057-1976/2/6/065016</pub-id>
</citation>
</ref>
<ref id="B17">
<label>17</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Reggiori</surname> <given-names>G</given-names>
</name>
<name>
<surname>Mancosu</surname> <given-names>P</given-names>
</name>
<name>
<surname>Castiglioni</surname> <given-names>S</given-names>
</name>
<name>
<surname>Alongi</surname> <given-names>F</given-names>
</name>
<name>
<surname>Pellegrini</surname> <given-names>C</given-names>
</name>
<name>
<surname>Lobefalo</surname> <given-names>F</given-names>
</name>
<etal/>
</person-group>. <article-title>Can volumetric modulated arc therapy with flattening filter free beams play a role in stereotactic body radiotherapy for liver lesions? a volume-based analysis</article-title>. <source>Med Phys</source> (<year>2012</year>) <volume>39</volume>(<issue>2</issue>):<page-range>1112&#x2013;8</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1118/1.3679858</pub-id>
</citation>
</ref>
<ref id="B18">
<label>18</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bezjak</surname> <given-names>A</given-names>
</name>
<name>
<surname>Bradley</surname> <given-names>J</given-names>
</name>
<name>
<surname>Gaspar</surname> <given-names>L</given-names>
</name>
<name>
<surname>Timmerman</surname> <given-names>RD</given-names>
</name>
<name>
<surname>Gore</surname> <given-names>E</given-names>
</name>
<name>
<surname>Papiez</surname> <given-names>L</given-names>
</name>
<etal/>
</person-group>. <article-title>Seamless phase I/II study of stereotactic lung radiotherapy (SBRT) for early stage, centrally located, non-small cell lung cancer (NSCLC) in medically inoperable patients</article-title>. <source>RTOG</source> (<year>2012</year>) <volume>0813</volume>:<fpage>1</fpage>&#x2013;<lpage>81</lpage>.</citation>
</ref>
<ref id="B19">
<label>19</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Videtic</surname> <given-names>GM</given-names>
</name>
<name>
<surname>Hu</surname> <given-names>C</given-names>
</name>
<name>
<surname>Singh</surname> <given-names>AK</given-names>
</name>
<name>
<surname>Chang</surname> <given-names>JY</given-names>
</name>
<name>
<surname>Parker</surname> <given-names>W</given-names>
</name>
<name>
<surname>Olivier</surname> <given-names>KR</given-names>
</name>
<etal/>
</person-group>. <article-title>A randomized phase II study comparing 2 stereotactic body radiation therapy (SBRT) schedules for medically inoperable patients with stage I peripheral non-small cell lung cancer : NRG oncology RTOG 0915 (NCCTG N0927)</article-title>. <source>Int J Radiat Oncol Biol Phys</source> (<year>2015</year>) <volume>93</volume>:<page-range>757&#x2013;64</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.ijrobp.2015.07.2260</pub-id>
</citation>
</ref>
<ref id="B20">
<label>20</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Takayama</surname> <given-names>K</given-names>
</name>
<name>
<surname>Nagata</surname> <given-names>Y</given-names>
</name>
<name>
<surname>Negoro</surname> <given-names>Y</given-names>
</name>
<name>
<surname>Mizowaki</surname> <given-names>T</given-names>
</name>
<name>
<surname>Sakamoto</surname> <given-names>T</given-names>
</name>
<name>
<surname>Sakamoto</surname> <given-names>M</given-names>
</name>
<etal/>
</person-group>. <article-title>Treatment planning of stereotactic radiotherapy for solitary lung tumor</article-title>. <source>Int J Radiat Oncol Biol Phys</source> (<year>2005</year>) <volume>61</volume>(<issue>5</issue>):<page-range>1565&#x2013;71</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.ijrobp.2004.12.066</pub-id>
</citation>
</ref>
<ref id="B21">
<label>21</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wulf</surname> <given-names>J</given-names>
</name>
<name>
<surname>H&#xe4;dinger</surname> <given-names>U</given-names>
</name>
<name>
<surname>Oppitz</surname> <given-names>U</given-names>
</name>
<name>
<surname>Thiele</surname> <given-names>W</given-names>
</name>
<name>
<surname>Ness-Dourdoumas</surname> <given-names>R</given-names>
</name>
<name>
<surname>Flentje</surname> <given-names>M</given-names>
</name>
</person-group>. <article-title>Stereotactic radiotherapy of targets in the lung and liver</article-title>. <source>Strahlenther Onkol</source> (<year>2001</year>) <volume>177</volume>:<page-range>645&#x2013;55</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1007/PL00002379</pub-id>
</citation>
</ref>
<ref id="B22">
<label>22</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Audet</surname> <given-names>C</given-names>
</name>
<name>
<surname>Poffenbarger</surname> <given-names>BA</given-names>
</name>
<name>
<surname>Chang</surname> <given-names>P</given-names>
</name>
<name>
<surname>Jackson</surname> <given-names>PS</given-names>
</name>
<name>
<surname>Lundahl</surname> <given-names>RE</given-names>
</name>
<name>
<surname>Ryu</surname> <given-names>SI</given-names>
</name>
<etal/>
</person-group>. <article-title>Evaluation of volumetric modulated arc therapy for cranial radiosurgery using multiple noncoplanar arcs</article-title>. <source>Med Phys</source> (<year>2011</year>) <volume>38</volume>(<issue>11</issue>):<page-range>5863&#x2013;72</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1118/1.3641874</pub-id>
</citation>
</ref>
<ref id="B23">
<label>23</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Paddick</surname> <given-names>I</given-names>
</name>
</person-group>. <article-title>A simple scoring ratio to index the conformity of radiosurgical treatment plans</article-title>. <source>J Neurosurg</source> (<year>2000</year>) <volume>93</volume>(<issue>3</issue>):<page-range>219&#x2013;22</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.3171/jns.2000.93.supplement_3.0219</pub-id>
</citation>
</ref>
<ref id="B24">
<label>24</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Paddick</surname> <given-names>I</given-names>
</name>
<name>
<surname>Lippitz</surname> <given-names>B</given-names>
</name>
</person-group>. <article-title>A simple dose gradient measurement tool to complement the conformity index</article-title>. <source>J Neurosurg</source> (<year>2006</year>) <volume>123</volume>:<fpage>194</fpage>&#x2013;<lpage>201</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.3171/sup.2006.105.7.194</pub-id>
</citation>
</ref>
<ref id="B25">
<label>25</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Jones</surname> <given-names>B</given-names>
</name>
<name>
<surname>Dale</surname> <given-names>RG</given-names>
</name>
<name>
<surname>Deehan</surname> <given-names>C</given-names>
</name>
<name>
<surname>Hopkins</surname> <given-names>KI</given-names>
</name>
<name>
<surname>Morgan</surname> <given-names>DAL</given-names>
</name>
</person-group>. <article-title>The role of biologically effective dose (BED) in clinical oncology</article-title>. <source>Clin Oncol-uk</source> (<year>2001</year>) <volume>13</volume>(<issue>2</issue>):<fpage>71</fpage>&#x2013;<lpage>81</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1053/clon.2001.9221</pub-id>
</citation>
</ref>
<ref id="B26">
<label>26</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Borst</surname> <given-names>GR</given-names>
</name>
<name>
<surname>Ishikawa</surname> <given-names>M</given-names>
</name>
<name>
<surname>Nijkamp</surname> <given-names>J</given-names>
</name>
<name>
<surname>Hauptmann</surname> <given-names>M</given-names>
</name>
<name>
<surname>Shirato</surname> <given-names>H</given-names>
</name>
<name>
<surname>Bengua</surname> <given-names>G</given-names>
</name>
<etal/>
</person-group>. <article-title>Radiation pneumonitis after hypofractionated radiotherapy: Evaluation of the LQ(L) model and different dose parameters</article-title>. <source>Int J Radiat Oncol Biol Phys</source> (<year>2010</year>) <volume>77</volume>(<issue>5</issue>):<page-range>1596&#x2013;603</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.ijrobp.2009.10.015</pub-id>
</citation>
</ref>
<ref id="B27">
<label>27</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lyman</surname> <given-names>JT</given-names>
</name>
</person-group>. <article-title>Complication probability as assessed from dose-volume histograms</article-title>. <source>Radiat Res Suppl</source> (<year>1985</year>) <volume>104</volume>(<issue>2</issue>):<page-range>S13&#x2013;9</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.2307/3583506</pub-id>
</citation>
</ref>
<ref id="B28">
<label>28</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Seppenwoolde</surname> <given-names>Y</given-names>
</name>
<name>
<surname>Lebesque</surname> <given-names>JV</given-names>
</name>
<name>
<surname>De Jaeger</surname> <given-names>K</given-names>
</name>
<name>
<surname>Boersma</surname> <given-names>LJ</given-names>
</name>
<name>
<surname>Schilstra</surname> <given-names>C</given-names>
</name>
<name>
<surname>Henning</surname> <given-names>GT</given-names>
</name>
<etal/>
</person-group>. <article-title>Comparing different NTCP models that predict the incidence of radiation pneumonitis. normal tissue complication probability</article-title>. <source>Int J Radiat Oncol Biol Phys</source> (<year>2003</year>) <volume>55</volume>(<issue>3</issue>):<page-range>724&#x2013;35</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/s0360-3016(02)03986-x</pub-id>
</citation>
</ref>
<ref id="B29">
<label>29</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Baker</surname> <given-names>R</given-names>
</name>
<name>
<surname>Han</surname> <given-names>G</given-names>
</name>
<name>
<surname>Sarangkasiri</surname> <given-names>S</given-names>
</name>
<name>
<surname>Demarco</surname> <given-names>ML</given-names>
</name>
<name>
<surname>Turke</surname> <given-names>C</given-names>
</name>
<name>
<surname>Stevens</surname> <given-names>CW</given-names>
</name>
<etal/>
</person-group>. <article-title>Clinical and dosimetric predictors of radiation pneumonitis in a large series of patients treated with stereotactic body radiation therapy to the lung</article-title>. <source>Int J Radiat Oncol Biol Phys</source> (<year>2013</year>) <volume>85</volume>(<issue>1</issue>):<page-range>190&#x2013;5</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.ijrobp.2012.03.041</pub-id>
</citation>
</ref>
<ref id="B30">
<label>30</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Vassiliev</surname> <given-names>ON</given-names>
</name>
<name>
<surname>Peterson</surname> <given-names>CB</given-names>
</name>
<name>
<surname>Chang</surname> <given-names>JY</given-names>
</name>
<name>
<surname>Radhe</surname> <given-names>M</given-names>
</name>
</person-group>. <article-title>Using FFF beams to improve the therapeutic ratio of lung SBRT</article-title>. <source>J Radiother Pract</source> (<year>2021</year>) <volume>20</volume>(<issue>4</issue>):<page-range>419&#x2013;25</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1017/S1460396920000576</pub-id>
</citation>
</ref>
<ref id="B31">
<label>31</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hebacek</surname> <given-names>J</given-names>
</name>
<name>
<surname>Lang</surname> <given-names>S</given-names>
</name>
<name>
<surname>Kl&#xf6;ck</surname> <given-names>S</given-names>
</name>
</person-group>. <article-title>Commissioning of photon beams of a flattening filter-free linear accelerator and the accuracy of beam modeling using an anisotropic analytical algorithm</article-title>. <source>Int J Radiat Oncol Biol Phys</source> (<year>2011</year>) <volume>80</volume>(<issue>4</issue>):<page-range>1228&#x2013;37</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.ijrobp.2010.09.050</pub-id>
</citation>
</ref>
<ref id="B32">
<label>32</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Srivastava</surname> <given-names>SP</given-names>
</name>
<name>
<surname>Cheng</surname> <given-names>CW</given-names>
</name>
<name>
<surname>Das</surname> <given-names>IJ</given-names>
</name>
</person-group>. <article-title>The dosimetric and radiobiological impact of calculation grid size on head and neck IMRT</article-title>. <source>Pract Radiat Oncol</source> (<year>2017</year>) <volume>7</volume>(<issue>3</issue>):<page-range>209&#x2013;17</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.prro.2016.10.001</pub-id>
</citation>
</ref>
<ref id="B33">
<label>33</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Timmeren</surname> <given-names>JV</given-names>
</name>
<name>
<surname>Ehrbar</surname> <given-names>S</given-names>
</name>
<name>
<surname>Chamberlain</surname> <given-names>M</given-names>
</name>
<name>
<surname>Mayinger</surname> <given-names>M</given-names>
</name>
<name>
<surname>Hoogeman</surname> <given-names>M</given-names>
</name>
<name>
<surname>Andratschke</surname> <given-names>N</given-names>
</name>
<etal/>
</person-group>. <article-title>Single-isocenter versus multiple-isocenters for multiple lung metastases: Evaluation of lung dose</article-title>. <source>Radiother Oncol</source> (<year>2022</year>) <volume>166</volume>:<page-range>189&#x2013;94</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.radonc.2021.11.030</pub-id>
</citation>
</ref>
<ref id="B34">
<label>34</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kang</surname> <given-names>SW</given-names>
</name>
<name>
<surname>Kang</surname> <given-names>S</given-names>
</name>
<name>
<surname>Lee</surname> <given-names>B</given-names>
</name>
<name>
<surname>Song</surname> <given-names>C</given-names>
</name>
<name>
<surname>Eom</surname> <given-names>KY</given-names>
</name>
<name>
<surname>Jang</surname> <given-names>BS</given-names>
</name>
<etal/>
</person-group>. <article-title>Evaluation of the dosimetric and radiobiological parameters in four radiotherapy regimens for synchronous bilateral breast cancer</article-title>. <source>J Appl Clin Med Phys</source> (<year>2022</year>) <volume>23</volume>(<issue>8</issue>):<elocation-id>e13706</elocation-id>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/acm2.13706</pub-id>
</citation>
</ref>
<ref id="B35">
<label>35</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hoffman</surname> <given-names>D</given-names>
</name>
<name>
<surname>Dragojevi&#x107;</surname> <given-names>I</given-names>
</name>
<name>
<surname>Hoisak</surname> <given-names>J</given-names>
</name>
<name>
<surname>Hoopes</surname> <given-names>D</given-names>
</name>
<name>
<surname>Manger</surname> <given-names>R</given-names>
</name>
</person-group>. <article-title>Lung stereotactic body radiation therapy (SBRT) dose gradient and PTV volume: A retrospective multi-center analysis</article-title>. <source>Radiat Oncol</source> (<year>2019</year>) <volume>14</volume>(<issue>1</issue>):<fpage>162</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1186/s13014-019-1334-9</pub-id>
</citation>
</ref>
<ref id="B36">
<label>36</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Fernandez</surname> <given-names>DJ</given-names>
</name>
<name>
<surname>Sick</surname> <given-names>JT</given-names>
</name>
<name>
<surname>Fontenot</surname> <given-names>JD</given-names>
</name>
</person-group>. <article-title>Interplay effects in highly modulated stereotactic body radiation therapy lung cases treated with volumetric modulated arc therapy</article-title>. <source>J Appl Clin Med Phys</source> (<year>2020</year>) <volume>21</volume>(<issue>11</issue>):<fpage>58</fpage>&#x2013;<lpage>69</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/acm2.13028</pub-id>
</citation>
</ref>
<ref id="B37">
<label>37</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kang</surname> <given-names>H</given-names>
</name>
<name>
<surname>Yorke</surname> <given-names>ED</given-names>
</name>
<name>
<surname>Yang</surname> <given-names>J</given-names>
</name>
<name>
<surname>Chui</surname> <given-names>C-S</given-names>
</name>
<name>
<surname>Rosenzweig</surname> <given-names>KE</given-names>
</name>
<name>
<surname>Amols</surname> <given-names>HI</given-names>
</name>
</person-group>. <article-title>Evaluation of tumor motion effects on dose distribution for hypofractionated intensity-modulated radiotherapy of non-small-cell lung cancer</article-title>. <source>J Appl Clin Med Phys</source> (<year>2010</year>) <volume>11</volume>(<issue>3</issue>):<fpage>78</fpage>&#x2013;<lpage>89</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1120/jacmp.v11i3.3182</pub-id>
</citation>
</ref>
<ref id="B38">
<label>38</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ong</surname> <given-names>CL</given-names>
</name>
<name>
<surname>Dahele</surname> <given-names>M</given-names>
</name>
<name>
<surname>Slotman</surname> <given-names>BJ</given-names>
</name>
<name>
<surname>Verbakel</surname> <given-names>W</given-names>
</name>
</person-group>. <article-title>Dosimetric impact of the interplay effect during stereotactic lung radiation therapy delivery using flattening filter-free beams and volumetric modulated arc therapy</article-title>. <source>Int J Radiat Oncol Biol Phys</source> (<year>2013</year>) <volume>86</volume>(<issue>4</issue>):<page-range>743&#x2013;8</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.ijrobp.2013.03.038</pub-id>
</citation>
</ref>
</ref-list>
</back>
</article>