<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" article-type="research-article" dtd-version="2.3" xml:lang="EN">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Oncol.</journal-id>
<journal-title>Frontiers in Oncology</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Oncol.</abbrev-journal-title>
<issn pub-type="epub">2234-943X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fonc.2022.853495</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Oncology</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Potential of a Second-Generation Dual-Layer Spectral CT for Dose Calculation in Particle Therapy Treatment Planning</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Longarino</surname>
<given-names>Friderike K.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
<xref ref-type="author-notes" rid="fn003">
<sup>&#x2020;</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1620547"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Kowalewski</surname>
<given-names>Antonia</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<xref ref-type="aff" rid="aff4">
<sup>4</sup>
</xref>
<xref ref-type="aff" rid="aff5">
<sup>5</sup>
</xref>
<xref ref-type="author-notes" rid="fn003">
<sup>&#x2020;</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1673435"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Tessonnier</surname>
<given-names>Thomas</given-names>
</name>
<xref ref-type="aff" rid="aff6">
<sup>6</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/207126"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Mein</surname>
<given-names>Stewart</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<xref ref-type="aff" rid="aff4">
<sup>4</sup>
</xref>
<xref ref-type="aff" rid="aff6">
<sup>6</sup>
</xref>
<xref ref-type="aff" rid="aff7">
<sup>7</sup>
</xref>
<xref ref-type="aff" rid="aff8">
<sup>8</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Ackermann</surname>
<given-names>Benjamin</given-names>
</name>
<xref ref-type="aff" rid="aff6">
<sup>6</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Debus</surname>
<given-names>J&#xfc;rgen</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<xref ref-type="aff" rid="aff6">
<sup>6</sup>
</xref>
<xref ref-type="aff" rid="aff7">
<sup>7</sup>
</xref>
<xref ref-type="aff" rid="aff8">
<sup>8</sup>
</xref>
<xref ref-type="aff" rid="aff9">
<sup>9</sup>
</xref>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Mairani</surname>
<given-names>Andrea</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<xref ref-type="aff" rid="aff6">
<sup>6</sup>
</xref>
<xref ref-type="aff" rid="aff8">
<sup>8</sup>
</xref>
<xref ref-type="aff" rid="aff10">
<sup>10</sup>
</xref>
<xref ref-type="author-notes" rid="fn001">
<sup>*</sup>
</xref>
<xref ref-type="author-notes" rid="fn004">
<sup>&#x2021;</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1388282"/>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Stiller</surname>
<given-names>Wolfram</given-names>
</name>
<xref ref-type="aff" rid="aff11">
<sup>11</sup>
</xref>
<xref ref-type="author-notes" rid="fn001">
<sup>*</sup>
</xref>
<xref ref-type="author-notes" rid="fn004">
<sup>&#x2021;</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1641142"/>
</contrib>
</contrib-group>
<aff id="aff1">
<sup>1</sup>
<institution>Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ)</institution>, <addr-line>Heidelberg</addr-line>, <country>Germany</country>
</aff>
<aff id="aff2">
<sup>2</sup>
<institution>Department of Radiation Oncology, Heidelberg University Hospital</institution>, <addr-line>Heidelberg</addr-line>, <country>Germany</country>
</aff>
<aff id="aff3">
<sup>3</sup>
<institution>Department of Physics and Astronomy, Heidelberg University</institution>, <addr-line>Heidelberg</addr-line>, <country>Germany</country>
</aff>
<aff id="aff4">
<sup>4</sup>
<institution>Translational Radiation Oncology, German Cancer Research Center (DKFZ)</institution>, <addr-line>Heidelberg</addr-line>, <country>Germany</country>
</aff>
<aff id="aff5">
<sup>5</sup>
<institution>Department of Physics, Simon Fraser University</institution>, <addr-line>Burnaby, BC</addr-line>, <country>Canada</country>
</aff>
<aff id="aff6">
<sup>6</sup>
<institution>Heidelberg Ion Beam Therapy Center (HIT)</institution>, <addr-line>Heidelberg</addr-line>, <country>Germany</country>
</aff>
<aff id="aff7">
<sup>7</sup>
<institution>Heidelberg Institute of Radiation Oncology (HIRO), National Center for Radiation Research in Oncology (NCRO)</institution>, <addr-line>Heidelberg</addr-line>, <country>Germany</country>
</aff>
<aff id="aff8">
<sup>8</sup>
<institution>National Center for Tumor Diseases (NCT)</institution>, <addr-line>Heidelberg</addr-line>, <country>Germany</country>
</aff>
<aff id="aff9">
<sup>9</sup>
<institution>German Cancer Consortium (DKTK), Core Center Heidelberg</institution>, <addr-line>Heidelberg</addr-line>, <country>Germany</country>
</aff>
<aff id="aff10">
<sup>10</sup>
<institution>Medical Physics, National Center of Oncological Hadrontherapy (CNAO)</institution>, <addr-line>Pavia</addr-line>, <country>Italy</country>
</aff>
<aff id="aff11">
<sup>11</sup>
<institution>Diagnostic and Interventional Radiology (DIR), Heidelberg University Hospital</institution>, <addr-line>Heidelberg</addr-line>, <country>Germany</country>
</aff>
<author-notes>
<fn fn-type="edited-by">
<p>Edited by: Tonghe Wang, Emory University, United States</p>
</fn>
<fn fn-type="edited-by">
<p>Reviewed by: Qian Wang, Emory University, United States; Ming Yang, University of Texas MD Anderson Cancer Center, United States</p>
</fn>
<fn fn-type="corresp" id="fn001">
<p>*Correspondence: Wolfram Stiller, <email xlink:href="mailto:wolfram.stiller@med.uni-heidelberg.de">wolfram.stiller@med.uni-heidelberg.de</email>; Andrea Mairani, <email xlink:href="mailto:andrea.mairani@med.uni-heidelberg.de">andrea.mairani@med.uni-heidelberg.de</email>
</p>
</fn>
<fn fn-type="equal" id="fn003">
<p>&#x2020;These authors have contributed equally to this work and share first authorship</p>
</fn>
<fn fn-type="equal" id="fn004">
<p>&#x2021;These authors have contributed equally to this work and share last authorship</p>
</fn>
<fn fn-type="other" id="fn002">
<p>This article was submitted to Radiation Oncology, a section of the journal Frontiers in Oncology</p>
</fn>
</author-notes>
<pub-date pub-type="epub">
<day>20</day>
<month>04</month>
<year>2022</year>
</pub-date>
<pub-date pub-type="collection">
<year>2022</year>
</pub-date>
<volume>12</volume>
<elocation-id>853495</elocation-id>
<history>
<date date-type="received">
<day>12</day>
<month>01</month>
<year>2022</year>
</date>
<date date-type="accepted">
<day>14</day>
<month>03</month>
<year>2022</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2022 Longarino, Kowalewski, Tessonnier, Mein, Ackermann, Debus, Mairani and Stiller</copyright-statement>
<copyright-year>2022</copyright-year>
<copyright-holder>Longarino, Kowalewski, Tessonnier, Mein, Ackermann, Debus, Mairani and Stiller</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<p>In particle therapy treatment planning, dose calculation is conducted using patient-specific maps of tissue ion stopping power ratio (SPR) to predict beam ranges. Improving patient-specific SPR prediction is therefore essential for accurate dose calculation. In this study, we investigated the use of the Spectral CT 7500, a second-generation dual-layer spectral computed tomography (DLCT) system, as an alternative to conventional single-energy CT (SECT) for patient-specific SPR prediction. This dual-energy CT (DECT)-based method allows for the direct prediction of SPR from quantitative measurements of relative electron density and effective atomic number using the Bethe equation, whereas the conventional SECT-based method consists of indirect image data-based prediction through the conversion of calibrated CT numbers to SPR. The performance of the Spectral CT 7500 in particle therapy treatment planning was characterized by conducting a thorough analysis of its SPR prediction accuracy for both tissue-equivalent materials and common non-tissue implant materials. In both instances, DLCT was found to reduce uncertainty in SPR predictions compared to SECT. Mean deviations of 0.7% and 1.6% from measured SPR values were found for DLCT- and SECT-based predictions, respectively, in tissue-equivalent materials. Furthermore, end-to-end analyses of DLCT-based treatment planning were performed for proton, helium, and carbon ion therapies with anthropomorphic head and pelvic phantoms. 3D gamma analysis was performed with ionization chamber array measurements as the reference. DLCT-predicted dose distributions revealed higher passing rates compared to SECT-predicted dose distributions. In the DLCT-based treatment plans, measured distal-edge evaluation layers were within 1 mm of their predicted positions, demonstrating the accuracy of DLCT-based particle range prediction. This study demonstrated that the use of the Spectral CT 7500 in particle therapy treatment planning may lead to better agreement between planned and delivered dose compared to current clinical SECT systems.</p>
</abstract>
<kwd-group>
<kwd>dual-layer spectral CT</kwd>
<kwd>particle therapy</kwd>
<kwd>Spectral CT 7500</kwd>
<kwd>stopping power ratio</kwd>
<kwd>range uncertainty</kwd>
<kwd>treatment planning</kwd>
</kwd-group>
<counts>
<fig-count count="3"/>
<table-count count="5"/>
<equation-count count="6"/>
<ref-count count="54"/>
<page-count count="11"/>
<word-count count="6281"/>
</counts>
</article-meta>
</front>
<body>
<sec id="s1" sec-type="intro">
<title>1 Introduction</title>
<p>The central goal of modern radiotherapy is the delivery of maximum radiation dose to tumors while minimizing radiation dose to healthy surrounding tissue. Particle therapy offers promising advancements in this regard (<xref ref-type="bibr" rid="B1">1</xref>), thanks to the favourable depth-dose curve of charged particles compared to conventional photon beams (X-rays) (<xref ref-type="bibr" rid="B2">2</xref>). However, to take full advantage of the benefits of particle therapy, it is essential to have precise, accurate, and patient-specific predictions of particle ranges within the body (<xref ref-type="bibr" rid="B3">3</xref>). For clinical treatment planning, predicted particle ranges are calculated from ion stopping power ratio (SPR) maps, which are in turn derived from patient computed tomography (CT) data. At present, CT numbers (CTNs) from single-energy CT (SECT) images are converted to SPR values using a generic, empirically validated conversion function called a Hounsfield look-up table (HLUT) (<xref ref-type="supplementary-material" rid="SM1">
<bold>Supplementary Figure&#xa0;1</bold>
</xref>). This approach to SPR prediction is a main source of beam range uncertainty, as HLUTs do not account for degeneracies between CTN and SPR values, nor for variability in tissue composition between patients (<xref ref-type="bibr" rid="B4">4</xref>&#x2013;<xref ref-type="bibr" rid="B8">8</xref>).</p>
<p>Recently, dual-energy CT (DECT), clinically introduced for diagnostic imaging in 2006 (<xref ref-type="bibr" rid="B9">9</xref>), has been investigated as an alternative to SECT. In DECT, two CT data sets are acquired using different X-ray spectra, enabling the generation of relative electron density (ED) and effective atomic number (EAN) maps (<xref ref-type="bibr" rid="B10">10</xref>). From ED and EAN data, SPR values can be calculated through the Bethe equation without the need for a pre-defined HLUT (<xref ref-type="bibr" rid="B10">10</xref>,&#xa0;<xref ref-type="bibr" rid="B11">11</xref>). Both theoretical (<xref ref-type="bibr" rid="B5">5</xref>, <xref ref-type="bibr" rid="B10">10</xref>) and experimental (<xref ref-type="bibr" rid="B5">5</xref>, <xref ref-type="bibr" rid="B12">12</xref>&#x2013;<xref ref-type="bibr" rid="B22">22</xref>) studies have shown DECT to improve SPR prediction accuracy over SECT. Several imaging techniques and modalities exist to achieve DECT results, including dual-spiral, dual-source, rapid kV switching, twin-beam, and dual-layer technologies (<xref ref-type="bibr" rid="B7">7</xref>) (<xref ref-type="supplementary-material" rid="SM1">
<bold>Supplementary Tables&#xa0;1</bold>
</xref>, <xref ref-type="supplementary-material" rid="SM1">
<bold>2</bold>
</xref>). Of these, dual-layer spectral CT (DLCT) employs a double-layer detector to simultaneously acquire high- and low-energy X-ray data (<xref ref-type="bibr" rid="B23">23</xref>). This avoids exposing the patient to additional radiation (<xref ref-type="bibr" rid="B21">21</xref>), and achieves synchronicity between the low- and high-energy data acquisitions over the full scan field-of-view, facilitating the imaging of moving organs (<xref ref-type="bibr" rid="B24">24</xref>).</p>
<p>At present, the SPR prediction accuracy of DLCT has only been investigated using the Philips IQon Spectral CT (Philips Healthcare, Best, The Netherlands) (<xref ref-type="bibr" rid="B21">21</xref>, <xref ref-type="bibr" rid="B22">22</xref>, <xref ref-type="bibr" rid="B24">24</xref>&#x2013;<xref ref-type="bibr" rid="B27">27</xref>). Here, we investigate the SPR prediction accuracy of the new Philips Spectral CT 7500 (Philips Healthcare, Best, The Netherlands), commissioned at the Heidelberg University Hospital (Germany) for diagnostic use in February 2021 and officially released in May 2021. This scanner offers advantages over the Philips IQon Spectral CT, including a new high-performance patient table, a larger (anatomical) detector coverage enabling a greater number of simultaneously acquired slices per rotation (up to 256 versus 128), and a larger bore size (<xref ref-type="supplementary-material" rid="SM1">
<bold>Supplementary Table&#xa0;3</bold>
</xref>). The large bore size of 800 mm allows for easier access to patients, and better accommodation of patient accessories and obese patients. Furthermore, the Philips Spectral CT 7500 allows the generation of spectral results at 100, 120, and 140 kV<sub>p</sub>.</p>
<p>We seek to validate the Philips Spectral CT 7500 for particle therapy treatment planning by conducting a thorough analysis of its SPR prediction accuracy for both tissue-equivalent materials and common non-tissue implants. To our knowledge, this is the first study conducted on second-generation DLCT systems (i.e., Spectral CT 7500) and here we focus specifically on applications to particle therapy. We employed the same methodology as in the relevant publications on the first-generation system (<xref ref-type="bibr" rid="B22">22</xref>, <xref ref-type="bibr" rid="B25">25</xref>, <xref ref-type="bibr" rid="B27">27</xref>) in order to allow for direct comparability to results from prior studies. Furthermore, we perform end-to-end analyses for proton, helium ion, and carbon ion therapies with anthropomorphic head and pelvic phantoms.</p>
</sec>
<sec id="s2" sec-type="materials|methods">
<title>2 Materials and Methods</title>
<sec id="s2_1">
<title>2.1 CT Image Acquisition and Reconstruction</title>
<p>All images were acquired using the Philips Spectral CT 7500 scanner (Philips Healthcare, Best, The Netherlands) at the Heidelberg University Hospital with a standardized head or body protocol at 120 kV<sub>p</sub>. The image acquisition settings and reconstruction parameters for head and body protocols are specified in <xref ref-type="supplementary-material" rid="SM1">
<bold>Supplementary Table&#xa0;4</bold>
</xref>, and are based on current state-of-the-art clinical protocols used for particle therapy planning at the Heidelberg Ion Beam Therapy Center (HIT, Germany). Both SECT and DLCT image data are automatically generated from the same raw data set for each acquisition on the Spectral CT 7500 scanner, enabling a direct comparison of the two techniques.</p>
<p>Image reconstruction was performed using the iDose<sup>4</sup> algorithm at levels 0, 3, and 6 (Philips Healthcare, Best, The Netherlands). The iDose<sup>4</sup> algorithm uses a hybrid iterative reconstruction technique to reduce image noise, and has levels ranging from 0 to 6, where higher levels correspond to greater noise reduction. In this context, an iDose<sup>4</sup> level of 0 corresponds to conventional filtered back-projection image reconstruction. For imaging of metallic materials, the Philips orthopedic metal artifact reduction algorithm (O-MAR) (Philips Healthcare, Best, The Netherlands) was also applied.</p>
</sec>
<sec id="s2_2">
<title>2.2 SPR Prediction and Validation in Geometric Phantoms</title>
<p>The SPR prediction accuracy of the Philips Spectral CT 7500 scanner was first investigated using a number of custom cylindrical polymethyl methacrylate (PMMA) phantoms with tissue-equivalent inserts spanning the range of clinically relevant CTNs (<xref ref-type="fig" rid="f1">
<bold>Figure&#xa0;1</bold>
</xref>). Five PMMA phantoms were used to simulate different patient sizes: two one-bore cylinders of height 46.0 cm and radius 5.0 cm (&#x201c;LCT&#x201d;, &#x201c;long cylinder thin&#x201d;) and 8.0 cm (&#x201c;LC&#x201d;, &#x201c;long cylinder&#x201d;), two nine-bore cylinders of height 10.0 cm and radius 8.0 cm (&#x201c;SC&#x201d;, &#x201c;short cylinder&#x201d;) and 16.0 cm (&#x201c;SCB&#x201d;, &#x201c;short cylinder big&#x201d;), and a roughly human-shaped pelvis. Thirteen tissue-equivalent cylindrical inserts (Gammex Electron Density CT Phantom 467, Gammex-RMI, Middleton, WI, USA) of height 7.0 cm and radius 1.4 cm were used as bore inserts: cortical bone, CB2 50%, CB2 30%, inner bone, muscle, brain, adipose, true water, liver, solid water, breast, bone mineral, and lung. Reference SPR values of these inserts were determined experimentally at HIT by measuring the range shift of a carbon ion beam in a water absorber (Peakfinder Water Column, PTW-Freiburg, Freiburg, Germany). Carbon ions were used for the measurement due to their sharper Bragg peak, reduced lateral scattering, and reduced range straggling compared to protons (<xref ref-type="bibr" rid="B22">22</xref>). The inserts were placed in the phantoms in specific configurations to minimize artifacts caused by the high-density bone-equivalent inserts (<xref ref-type="bibr" rid="B14">14</xref>).</p>
<fig id="f1" position="float">
<label>Figure&#xa0;1</label>
<caption>
<p>Custom polymethyl methacrylate (PMMA) phantoms with tissue-equivalent inserts in axial view. <bold>(A)</bold> LCT (&#x201c;long cylinder thin&#x201d;) phantom, <bold>(B)</bold> LC (&#x201c;long cylinder&#x201d;) phantom, <bold>(C)</bold> SC (&#x201c;short cylinder&#x201d;) phantom, <bold>(D)</bold> SCB (&#x201c;short cylinder big&#x201d;) phantom, <bold>(E)</bold> LC (&#x201c;long cylinder&#x201d;) phantom (in coronal view), <bold>(F)</bold> pelvis phantom. Window level/window width = 40/400 HU.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fonc-12-853495-g001.tif"/>
</fig>
<p>Furthermore, a selection of materials commonly found in non-tissue implants were scanned for SPR prediction. The metals aluminum and titanium and a carbon/PEEK-titanium composite (icotec ag, Altst&#xe4;tten, Switzerland) were imaged in the LC phantom, along with the special materials PMMA, TECAFORM<sup>&#xae;</sup> and TECAPEEK<sup>&#xae;</sup> (Ensinger GmbH, Nufringen, Germany), and Teflon&#x2122; (The Chemours Company, Wilmington, DE, USA). In addition, PALACOS<sup>&#xae;</sup> R + G bone cement (Heraeus, Hanau, Germany) was imaged in a water bath.</p>
<sec id="s2_2_1">
<title>2.2.1 Calculation of Predicted SPR Values Based on Quantitative DLCT Data</title>
<p>Predicted SPR values were calculated from DLCT-generated ED and EAN maps using the Bethe equation neglecting higher order correction terms (<xref ref-type="bibr" rid="B11">11</xref>), as described in Faller et&#xa0;al. (<xref ref-type="bibr" rid="B22">22</xref>). The mean excitation energy (I-value) of the tissue was calculated from EAN data using the method outlined in Yang et&#xa0;al. (<xref ref-type="bibr" rid="B10">10</xref>). The I-value of water was set to 78.73 eV, consistent with the values proposed by B&#xe4;r et&#xa0;al. (<xref ref-type="bibr" rid="B28">28</xref>) and the International Commission on Radiation Units and Measurements (<xref ref-type="bibr" rid="B29">29</xref>). A fixed particle kinetic energy of 100 MeV per nucleon was assumed, as recommended by Inaniwa &amp; Kanematsu (<xref ref-type="bibr" rid="B30">30</xref>), since the energy dependence of SPR prediction is minimal in the therapeutic range (<xref ref-type="bibr" rid="B31">31</xref>).</p>
</sec>
<sec id="s2_2_2">
<title>2.2.2 Calculation of Predicted SPR Values Based on Conventional SECT Image Data</title>
<p>For each of the two imaging protocols (head and body), an HLUT was generated from 120 kV<sub>p</sub> SECT image data acquired using the given protocol. A two-parameter stoichiometric parametrization (<xref ref-type="bibr" rid="B11">11</xref>, <xref ref-type="bibr" rid="B32">32</xref>) was applied to generate the HLUT, following the current clinical protocol at HIT (<xref ref-type="bibr" rid="B33">33</xref>). The generated HLUT was then used to convert CTNs to SPR values (<xref ref-type="supplementary-material" rid="SM1">
<bold>Supplementary Figure&#xa0;1</bold>
</xref>).</p>
</sec>
<sec id="s2_2_3">
<title>2.2.3 Assessment of DLCT- and SECT-Based SPR Predictions</title>
<p>Predicted SPR values of cylindrical phantom inserts were extracted for analysis using circular regions-of-interest (ROIs) with a size of ~70% of the inserts&#x2019; cross-sectional diameters. This strategy avoided possible artifacts caused by gradient effects to the surrounding PMMA near the insert&#x2013;phantom boundary. ROI slices towards both ends of the inserts were also excluded for similar reasons. Predicted SPR values of the PALACOS<sup>&#xae;</sup> R + G bone cement, imaged in a water bath, were extracted for analysis using a similar method, where ROIs were evaluated at cross-sectional locations along the longest axis of the bone cement sample.</p>
<p>The agreement of predicted SPR values (SPR<sub>pre</sub>) with reference values (SPR<sub>ref</sub>) was quantified using relative residuals, defined as</p>
<disp-formula>
<mml:math display="block" id="M1">
<mml:mrow>
<mml:mi>r</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>a</mml:mi>
<mml:mi>t</mml:mi>
<mml:mi>i</mml:mi>
<mml:mi>v</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi> </mml:mi>
<mml:mi>r</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>s</mml:mi>
<mml:mi>i</mml:mi>
<mml:mi>d</mml:mi>
<mml:mi>u</mml:mi>
<mml:mi>a</mml:mi>
<mml:mi>l</mml:mi>
<mml:mo>=</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mi>P</mml:mi>
<mml:msub>
<mml:mi>R</mml:mi>
<mml:mrow>
<mml:mi>p</mml:mi>
<mml:mi>r</mml:mi>
<mml:mi>e</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>S</mml:mi>
<mml:mi>P</mml:mi>
<mml:msub>
<mml:mi>R</mml:mi>
<mml:mrow>
<mml:mi>r</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>f</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mi>P</mml:mi>
<mml:msub>
<mml:mi>R</mml:mi>
<mml:mrow>
<mml:mi>r</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>f</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:mfrac>
<mml:mo>&#xb7;</mml:mo>
<mml:mn>100</mml:mn>
<mml:mo stretchy="false">%</mml:mo>
</mml:mrow>
</mml:math>
</disp-formula>
<p>For each phantom&#x2013;protocol combination, the mean overall relative residual was computed using the formula</p>
<disp-formula>
<mml:math display="block" id="M3">
<mml:mrow>
<mml:mi>m</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>a</mml:mi>
<mml:mi>n</mml:mi>
<mml:mi> </mml:mi>
<mml:mi>o</mml:mi>
<mml:mi>v</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>r</mml:mi>
<mml:mi>a</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi> </mml:mi>
<mml:mi>r</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>a</mml:mi>
<mml:mi>t</mml:mi>
<mml:mi>i</mml:mi>
<mml:mi>v</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi> </mml:mi>
<mml:mi>r</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>s</mml:mi>
<mml:mi>i</mml:mi>
<mml:mi>d</mml:mi>
<mml:mi>u</mml:mi>
<mml:mi>a</mml:mi>
<mml:mi>l</mml:mi>
<mml:mo>=</mml:mo>
<mml:mfrac>
<mml:mn>1</mml:mn>
<mml:mi>N</mml:mi>
</mml:mfrac>
<mml:msubsup>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mo>=</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>N</mml:mi>
</mml:msubsup>
<mml:mrow>
<mml:mo>|</mml:mo> <mml:mrow>
<mml:mi>r</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>a</mml:mi>
<mml:mi>t</mml:mi>
<mml:mi>i</mml:mi>
<mml:mi>v</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi> </mml:mi>
<mml:mi>r</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>s</mml:mi>
<mml:mi>i</mml:mi>
<mml:mi>d</mml:mi>
<mml:mi>u</mml:mi>
<mml:mi>a</mml:mi>
<mml:mi>l</mml:mi>
</mml:mrow> <mml:mo>|</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:math>
</disp-formula>
<p>Additionally, for each phantom&#x2013;protocol combination, the root-mean-square error (RMSE) and Pearson&#x2019;s correlation coefficient (<italic>r</italic>) between predicted and reference SPR values were determined, using the formulas</p>
<disp-formula>
<mml:math display="block" id="M5">
<mml:mrow>
<mml:mi>R</mml:mi>
<mml:mi>M</mml:mi>
<mml:mi>S</mml:mi>
<mml:mi>E</mml:mi>
<mml:mo>=</mml:mo>
<mml:msqrt>
<mml:mrow>
<mml:mfrac>
<mml:mn>1</mml:mn>
<mml:mi>N</mml:mi>
</mml:mfrac>
<mml:mstyle displaystyle="true">
<mml:munderover>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mo>=</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>N</mml:mi>
</mml:munderover>
<mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mi>P</mml:mi>
<mml:msub>
<mml:mi>R</mml:mi>
<mml:mrow>
<mml:mi>p</mml:mi>
<mml:mi>r</mml:mi>
<mml:mi>e</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>i</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>S</mml:mi>
<mml:mi>P</mml:mi>
<mml:msub>
<mml:mi>R</mml:mi>
<mml:mrow>
<mml:mi>r</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>f</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>i</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msup>
</mml:mrow>
</mml:mstyle>
</mml:mrow>
</mml:msqrt>
</mml:mrow>
</mml:math>
</disp-formula>
<p>and</p>
<disp-formula>
<mml:math display="block" id="M2">
<mml:mrow>
<mml:mi>r</mml:mi>
<mml:mo>=</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:msubsup>
<mml:mi>&#x3a3;</mml:mi>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mo>=</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>N</mml:mi>
</mml:msubsup>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>S</mml:mi>
<mml:mi>P</mml:mi>
<mml:msub>
<mml:mi>R</mml:mi>
<mml:mrow>
<mml:mi>r</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>f</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>i</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:mover accent="true">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mi>P</mml:mi>
<mml:msub>
<mml:mi>R</mml:mi>
<mml:mrow>
<mml:mi>r</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>f</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mo stretchy="true">&#xaf;</mml:mo>
</mml:mover>
<mml:mo stretchy="false">)</mml:mo>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>S</mml:mi>
<mml:mi>P</mml:mi>
<mml:msub>
<mml:mi>R</mml:mi>
<mml:mrow>
<mml:mi>p</mml:mi>
<mml:mi>r</mml:mi>
<mml:mi>e</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>i</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:mover accent="true">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mi>P</mml:mi>
<mml:msub>
<mml:mi>R</mml:mi>
<mml:mrow>
<mml:mi>p</mml:mi>
<mml:mi>r</mml:mi>
<mml:mi>e</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mo stretchy="true">&#xaf;</mml:mo>
</mml:mover>
<mml:mo stretchy="false">)</mml:mo>
</mml:mrow>
<mml:mrow>
<mml:msqrt>
<mml:mrow>
<mml:msubsup>
<mml:mi>&#x3a3;</mml:mi>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mo>=</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>N</mml:mi>
</mml:msubsup>
<mml:msup>
<mml:mrow>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>S</mml:mi>
<mml:mi>P</mml:mi>
<mml:msub>
<mml:mi>R</mml:mi>
<mml:mrow>
<mml:mi>r</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>f</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>i</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:mover accent="true">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mi>P</mml:mi>
<mml:msub>
<mml:mi>R</mml:mi>
<mml:mrow>
<mml:mi>r</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>f</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mo stretchy="true">&#xaf;</mml:mo>
</mml:mover>
<mml:mo stretchy="false">)</mml:mo>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msup>
</mml:mrow>
</mml:msqrt>
<mml:msqrt>
<mml:mrow>
<mml:msubsup>
<mml:mi>&#x3a3;</mml:mi>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mo>=</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>N</mml:mi>
</mml:msubsup>
<mml:msup>
<mml:mrow>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>S</mml:mi>
<mml:mi>P</mml:mi>
<mml:msub>
<mml:mi>R</mml:mi>
<mml:mrow>
<mml:mi>p</mml:mi>
<mml:mi>r</mml:mi>
<mml:mi>e</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>i</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:mover accent="true">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mi>P</mml:mi>
<mml:msub>
<mml:mi>R</mml:mi>
<mml:mrow>
<mml:mi>p</mml:mi>
<mml:mi>r</mml:mi>
<mml:mi>e</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mo stretchy="true">&#xaf;</mml:mo>
</mml:mover>
<mml:mo stretchy="false">)</mml:mo>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msup>
</mml:mrow>
</mml:msqrt>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:math>
</disp-formula>
<p>respectively. In both cases, N is the number of cylindrical inserts in a given phantom. In the Pearson&#x2019;s correlation coefficient formula, the bars represent arithmetic means.</p>
<p>Finally, predicted SPR values were fitted to reference values using linear regression, with parameters <italic>&#x3b1;</italic> and <italic>&#x3b4;</italic>:</p>
<disp-formula>
<mml:math display="block" id="M9">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mi>P</mml:mi>
<mml:msub>
<mml:mi>R</mml:mi>
<mml:mrow>
<mml:mi>p</mml:mi>
<mml:mi>r</mml:mi>
<mml:mi>e</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>=</mml:mo>
<mml:mi>&#x3b1;</mml:mi>
<mml:mo>&#xb7;</mml:mo>
<mml:mi>S</mml:mi>
<mml:mi>P</mml:mi>
<mml:msub>
<mml:mi>R</mml:mi>
<mml:mrow>
<mml:mi>r</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>f</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>+</mml:mo>
<mml:mi>&#x3b4;</mml:mi>
</mml:mrow>
</mml:math>
</disp-formula>
<p>Pearson&#x2019;s correlation coefficient (<italic>r</italic>) and linear regression fitting parameters (<italic>&#x3b1;</italic> and <italic>&#x3b4;</italic>) were used to quantify the agreement of DLCT- and SECT-based SPR predictions with measured reference values.</p>
</sec>
<sec id="s2_2_4">
<title>2.2.4 Evaluation of DLCT-Based Mass Density Calculation</title>
<p>We implemented and evaluated the DEEDZ-MD method proposed by Saito (<xref ref-type="bibr" rid="B34">34</xref>) to derive mass density (&#x3c1;) from DLCT data. &#x3c1; was calculated from DLCT-based ED (&#x3c1;<sub>e</sub>) and EAN (Z<sub>eff</sub>) values, with the EAN of water being Z<sub>eff,w</sub>:</p>
<disp-formula>
<mml:math display="block" id="M11">
<mml:mrow>
<mml:mi>&#x3c1;</mml:mi>
<mml:mo>=</mml:mo>
<mml:msub>
<mml:mi>&#x3c1;</mml:mi>
<mml:mi>e</mml:mi>
</mml:msub>
<mml:mo>+</mml:mo>
<mml:msub>
<mml:mi>&#x3c1;</mml:mi>
<mml:mi>e</mml:mi>
</mml:msub>
<mml:mstyle displaystyle="true">
<mml:msubsup>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi>n</mml:mi>
<mml:mo>=</mml:mo>
<mml:mn>0</mml:mn>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msubsup>
<mml:mrow>
<mml:msub>
<mml:mi>e</mml:mi>
<mml:mi>n</mml:mi>
</mml:msub>
<mml:msup>
<mml:mrow>
<mml:mrow>
<mml:mo>{</mml:mo> <mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mfrac>
<mml:mrow>
<mml:msub>
<mml:mi>Z</mml:mi>
<mml:mrow>
<mml:mi>e</mml:mi>
<mml:mi>f</mml:mi>
<mml:mi>f</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mrow>
<mml:msub>
<mml:mi>Z</mml:mi>
<mml:mrow>
<mml:mi>e</mml:mi>
<mml:mi>f</mml:mi>
<mml:mi>f</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>w</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mi>m</mml:mi>
</mml:msup>
<mml:mo>&#x2212;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow> <mml:mo>}</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mi>n</mml:mi>
</mml:msup>
</mml:mrow>
</mml:mstyle>
</mml:mrow>
</mml:math>
</disp-formula>
<p>The value of m was set to 3.3, as determined in Saito &amp; Sagara (<xref ref-type="bibr" rid="B35">35</xref>), and the same human tissue-specific parameters (e<sub>n</sub>) as obtained in Saito (<xref ref-type="bibr" rid="B34">34</xref>) were employed.</p>
</sec>
</sec>
<sec id="s2_3">
<title>2.3 Treatment Planning and Dosimetric Validation With Anthropomorphic Head and Pelvic Phantoms</title>
<p>The clinical benefits of SPR prediction based on DLCT data were investigated and compared with the currently applied SECT approach by using tissue-equivalent anthropomorphic head (Proton Therapy Dosimetry Head, Model 731-HN) and pelvic (Virtual Human Male Pelvis Phantom, Model 801-P) phantoms (Computerized Imaging Reference Systems, Inc. (CIRS), Norfolk, VA, USA).</p>
<p>Treatment planning optimizations with a dose grid of 1 mm were performed with RayStation Treatment Planning System v10 (RaySearch Laboratories AB, Stockholm, Sweden), using the Monte-Carlo dose engine for proton beams and the pencil beam dose engine for helium and carbon ion beams (<xref ref-type="fig" rid="f2">
<bold>Figure&#xa0;2</bold>
</xref>). The target position for each anthropomorphic phantom was selected such that it was located underneath multiple different tissue-equivalent layers, in order to test the various range prediction methods in heterogenous conditions. For the head phantom, an 8 x 8 x 3 cm<sup>3</sup> target volume located at the mid-head was optimized for a physical dose of 1 Gy (<xref ref-type="fig" rid="f2">
<bold>Figure&#xa0;2A</bold>
</xref>). For the pelvic phantom, two target types were optimized for a physical dose of 1 Gy: a prostate-like geometry of 52 cm<sup>3</sup> (<xref ref-type="fig" rid="f2">
<bold>Figure&#xa0;2B</bold>
</xref>) and a 6 x 6 x 6 cm<sup>3</sup> target volume (<xref ref-type="fig" rid="f2">
<bold>Figure&#xa0;2C</bold>
</xref>).</p>
<fig id="f2" position="float">
<label>Figure&#xa0;2</label>
<caption>
<p>Proton therapy treatment plans designed with the RayStation Treatment Planning System. <bold>(A)</bold> Head phantom with an 8 x 8 x 3 cm<sup>3</sup> target volume, <bold>(B)</bold> pelvic phantom with a prostate-like target volume of 52 cm<sup>3</sup>, <bold>(C)</bold> pelvic phantom with a 6 x 6 x 6 cm<sup>3</sup> target volume.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fonc-12-853495-g002.tif"/>
</fig>
<p>Treatment planning was initially performed with a conventional clinically-employed SECT scanner (SOMATOM Confidence, Siemens Healthcare GmbH, Erlangen, Germany) with a CT resolution of 0.977 x 0.977 x 1 mm<sup>3</sup> (head)/0.977 x 0.977 x 2 mm<sup>3</sup> (pelvis). Following plan optimization, forward dose calculations were performed on two additional (image) datasets from the Philips Spectral CT 7500: one using the SECT approach and one using the DLCT approach for SPR prediction.</p>
<p>Dosimetric measurements were acquired at HIT with the OCTAVIUS<sup>&#xae;</sup> 1000SRS P (PTW, Freiburg, Germany) prototype 2D ionization chamber array detector for proton, helium ion, and carbon ion beam treatment plans, as described in previous works (<xref ref-type="bibr" rid="B36">36</xref>). For both phantoms, measurements were performed in the high-dose area and at different positions along the distal edge. For the head phantom, irradiation was performed using the gantry at an angle of 0&#xb0; with the half-head phantom placed on top of the OCTAVIUS<sup>&#xae;</sup> detector (<xref ref-type="supplementary-material" rid="SM1">
<bold>Supplementary Figure&#xa0;2A</bold>
</xref>). For the pelvic phantom, irradiation was performed using the horizontal beam line with the half-pelvic phantom placed in front of the OCTAVIUS<sup>&#xae;</sup> detector (<xref ref-type="supplementary-material" rid="SM1">
<bold>Supplementary Figure&#xa0;2B</bold>
</xref>).</p>
<p>Dose distributions were compared using a 3D gamma analysis (<xref ref-type="bibr" rid="B37">37</xref>) for local calculation with a passing criterion of 3%/1.5 mm using a low dose cut-off of 5% of the maximum dose.</p>
</sec>
</sec>
<sec id="s3" sec-type="results">
<title>3 Results</title>
<sec id="s3_1">
<title>3.1 CT Image Acquisition and Reconstruction</title>
<p>CT (image) data acquired using the head and body protocols produced similarly accurate SPR predictions (<xref ref-type="supplementary-material" rid="SM1">
<bold>Supplementary Tables&#xa0;5</bold>
</xref>, <xref ref-type="supplementary-material" rid="SM1">
<bold>6</bold>
</xref>). As such, all reports of SPR prediction accuracy for the remainder of the study are based on CT images acquired using the body protocol, unless otherwise specified.</p>
<p>Similarly, the iDose<sup>4</sup> level used in image reconstruction was found to have no significant effect on the accuracy and standard deviation of predicted SPR values (<xref ref-type="supplementary-material" rid="SM1">
<bold>Supplementary Tables&#xa0;5</bold>
</xref>, <xref ref-type="supplementary-material" rid="SM1">
<bold>6</bold>
</xref>). Therefore, all results reported for the remainder of the study are based on CT (image) data reconstructed using iDose<sup>4</sup> level 0 (that is, with minimum additional iterative post-processing), unless otherwise specified.</p>
</sec>
<sec id="s3_2">
<title>3.2 SPR Prediction and Assessment in Geometric Phantoms</title>
<p>For tissue surrogates, SPR values predicted using DLCT were consistently closer to reference values than SPR values predicted using SECT in all five phantoms (<xref ref-type="fig" rid="f3">
<bold>Figure&#xa0;3</bold>
</xref>; <xref ref-type="table" rid="T1">
<bold>Tables&#xa0;1</bold>
</xref>, <xref ref-type="table" rid="T2">
<bold>2</bold>
</xref>). Pearson&#x2019;s correlation coefficient (<italic>r</italic>) and linear regression fitting parameters (<italic>&#x3b1;</italic> and <italic>&#x3b4;</italic>) confirmed higher agreement between measured and DLCT-predicted SPR values compared to SECT-predicted SPR values (<xref ref-type="table" rid="T1">
<bold>Tables&#xa0;1</bold>
</xref>, <xref ref-type="table" rid="T2">
<bold>2</bold>
</xref>). For consistency over all tissue-equivalent inserts, we focus solely on the LCT, LC, SC, and SCB phantoms for the remainder of the study, as not all inserts were imaged in the pelvis phantom.</p>
<fig id="f3" position="float">
<label>Figure&#xa0;3</label>
<caption>
<p>Relative residuals for DLCT- and SECT-based SPR predictions compared to reference values. <bold>(A)</bold> LCT (&#x201c;long cylinder thin&#x201d;) phantom, <bold>(B)</bold> LC (&#x201c;long cylinder&#x201d;) phantom, <bold>(C)</bold> SC (&#x201c;short cylinder&#x201d;) phantom, and <bold>(D)</bold> SCB (&#x201c;short cylinder big&#x201d;) phantom. The measurement of the LCT phantom was performed without the lung insert, as the lung insert did not fit into the LCT phantom due to its slightly larger diameter. Note the different scaling of the y-axis in <bold>(A)</bold>.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fonc-12-853495-g003.tif"/>
</fig>
<table-wrap id="T1" position="float">
<label>Table&#xa0;1</label>
<caption>
<p>Accuracy of DLCT-based SPR predictions across five different PMMA phantoms: LCT (&#x201c;long cylinder thin&#x201d;) phantom, LC (&#x201c;long cylinder&#x201d;) phantom, SC (&#x201c;short cylinder&#x201d;) phantom, SCB (&#x201c;short cylinder big&#x201d;) phantom, and a roughly human-shaped pelvis.</p>
</caption>
<table frame="hsides">
<thead>
<tr>
<th valign="top" align="left">Phantom</th>
<th valign="top" align="center">LCT</th>
<th valign="top" align="center">LC</th>
<th valign="top" align="center">SC</th>
<th valign="top" align="center">SCB</th>
<th valign="top" align="center">Pelvis</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Mean overall relative residual</td>
<td valign="top" align="center">0.688</td>
<td valign="top" align="center">0.725</td>
<td valign="top" align="center">0.613</td>
<td valign="top" align="center">0.675</td>
<td valign="top" align="center">0.816</td>
</tr>
<tr>
<td valign="top" align="left">RMSE</td>
<td valign="top" align="center">0.0093</td>
<td valign="top" align="center">0.0084</td>
<td valign="top" align="center">0.0056</td>
<td valign="top" align="center">0.0067</td>
<td valign="top" align="center">0.0116</td>
</tr>
<tr>
<td valign="top" align="left">
<italic>r</italic>
</td>
<td valign="top" align="center">0.9996</td>
<td valign="top" align="center">0.9998</td>
<td valign="top" align="center">0.9998</td>
<td valign="top" align="center">0.9997</td>
<td valign="top" align="center">0.9998</td>
</tr>
<tr>
<td valign="top" align="left">
<italic>&#x3b1;</italic>
</td>
<td valign="top" align="center">1.018</td>
<td valign="top" align="center">1.011</td>
<td valign="top" align="center">1.005</td>
<td valign="top" align="center">1.004</td>
<td valign="top" align="center">0.984</td>
</tr>
<tr>
<td valign="top" align="left">
<italic>&#x3b4;</italic>
</td>
<td valign="top" align="center">-0.014</td>
<td valign="top" align="center">-0.006</td>
<td valign="top" align="center">-0.002</td>
<td valign="top" align="center">0.000</td>
<td valign="top" align="center">0.010</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<p>The table shows the mean overall relative residual, root-mean-square error (RMSE), Pearson's correlation coefficient (r), and linear regression fitting parameters (&#x3b1; and &#x3b4;).</p>
</table-wrap-foot>
</table-wrap>
<table-wrap id="T2" position="float">
<label>Table&#xa0;2</label>
<caption>
<p>Accuracy of SECT-based SPR predictions across five different PMMA phantoms: LCT (&#x201c;long cylinder thin&#x201d;) phantom, LC (&#x201c;long cylinder&#x201d;) phantom, SC (&#x201c;short cylinder&#x201d;) phantom, SCB (&#x201c;short cylinder big&#x201d;) phantom, and a roughly human-shaped pelvis.</p>
</caption>
<table frame="hsides">
<thead>
<tr>
<th valign="top" align="left">Phantom</th>
<th valign="top" align="center">LCT</th>
<th valign="top" align="center">LC</th>
<th valign="top" align="center">SC</th>
<th valign="top" align="center">SCB</th>
<th valign="top" align="center">Pelvis</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Mean overall relative residual</td>
<td valign="top" align="center">1.833</td>
<td valign="top" align="center">1.538</td>
<td valign="top" align="center">1.514</td>
<td valign="top" align="center">1.685</td>
<td valign="top" align="center">0.859</td>
</tr>
<tr>
<td valign="top" align="left">RMSE</td>
<td valign="top" align="center">0.0307</td>
<td valign="top" align="center">0.0255</td>
<td valign="top" align="center">0.0243</td>
<td valign="top" align="center">0.0245</td>
<td valign="top" align="center">0.0101</td>
</tr>
<tr>
<td valign="top" align="left">
<italic>r</italic>
</td>
<td valign="top" align="center">0.9908</td>
<td valign="top" align="center">0.9956</td>
<td valign="top" align="center">0.9958</td>
<td valign="top" align="center">0.9962</td>
<td valign="top" align="center">0.9996</td>
</tr>
<tr>
<td valign="top" align="left">
<italic>&#x3b1;</italic>
</td>
<td valign="top" align="center">1.046</td>
<td valign="top" align="center">1.012</td>
<td valign="top" align="center">1.007</td>
<td valign="top" align="center">0.965</td>
<td valign="top" align="center">1.003</td>
</tr>
<tr>
<td valign="top" align="left">
<italic>&#x3b4;</italic>
</td>
<td valign="top" align="center">-0.044</td>
<td valign="top" align="center">-0.009</td>
<td valign="top" align="center">-0.008</td>
<td valign="top" align="center">0.033</td>
<td valign="top" align="center">-0.005</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<p>The table shows the mean overall relative residual, root-mean-square error (RMSE), Pearson's correlation coefficient (r), and linear regression fitting parameters (&#x3b1; and &#x3b4;).</p>
</table-wrap-foot>
</table-wrap>
<p>For the LCT phantom, DLCT-based SPR prediction had a mean overall relative residual of 0.7% (range: [-0.3, 1.4]%) while SECT-based SPR prediction had a mean overall relative residual of 1.8% (range: [-5.7, 5.3]%) (<xref ref-type="fig" rid="f3">
<bold>Figure&#xa0;3A</bold>
</xref>). For the LC phantom, DLCT-based SPR prediction had a mean overall relative residual of 0.7% (range: [-1.4, 1.6]%) while SECT-based SPR prediction had a mean overall relative residual of 1.5% (range: [-5.3, 4.7]%) (<xref ref-type="fig" rid="f3">
<bold>Figure&#xa0;3B</bold>
</xref>). For the SC phantom, DLCT-based SPR prediction had a mean overall relative residual of 0.6% (range: [-1.1, 1.5]%) while SECT-based SPR prediction had a mean overall relative residual of 1.5% (range: [-5.2, 4.3]%) (<xref ref-type="fig" rid="f3">
<bold>Figure&#xa0;3C</bold>
</xref>). Finally, for the SCB phantom, DLCT-based SPR prediction had a mean overall relative residual of 0.7% (range: [-1.2, 1.8]%) while SECT-based SPR prediction had a mean overall relative residual of 1.7% (range: [-4.3, 3.5]%) (<xref ref-type="fig" rid="f3">
<bold>Figure&#xa0;3D</bold>
</xref>). Across all four phantoms, the average mean overall relative residual was 0.7% for DLCT-based SPR prediction and 1.6% for SECT-based SPR prediction.</p>
<p>Accuracies of DLCT- and SECT-based SPR predictions across different non-tissue implant materials are listed in <xref ref-type="table" rid="T3">
<bold>Table&#xa0;3</bold>
</xref>. DLCT substantially outperformed SECT in predicting SPR values for all non-tissue materials. For the metals aluminium and titanium, SPR prediction accuracy was similar with and without the metal artifact reduction algorithm O-MAR. The HLUT derived in the SECT-based approach is shown together with the eight non-tissue implant materials in <xref ref-type="supplementary-material" rid="SM1">
<bold>Supplementary Figure&#xa0;1</bold>
</xref>.</p>
<table-wrap id="T3" position="float">
<label>Table&#xa0;3</label>
<caption>
<p>Accuracy of SECT- and DLCT-based SPR predictions across different non-tissue materials.</p>
</caption>
<table frame="hsides">
<thead>
<tr>
<th valign="top" align="left">Material</th>
<th valign="top" align="center">Relative residual SECT</th>
<th valign="top" align="center">Relative residual DLCT</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Aluminium</td>
<td valign="top" align="center">-7.5</td>
<td valign="top" align="center">6.9</td>
</tr>
<tr>
<td valign="top" align="left">Carbon/PEEK-titanium composite</td>
<td valign="top" align="center">-16.8</td>
<td valign="top" align="center">1.0</td>
</tr>
<tr>
<td valign="top" align="left">Palacos bone cement</td>
<td valign="top" align="center">45.0</td>
<td valign="top" align="center">8.1</td>
</tr>
<tr>
<td valign="top" align="left">PMMA</td>
<td valign="top" align="center">-6.7</td>
<td valign="top" align="center">1.3</td>
</tr>
<tr>
<td valign="top" align="left">Tecaform</td>
<td valign="top" align="center">-13.7</td>
<td valign="top" align="center">2.2</td>
</tr>
<tr>
<td valign="top" align="left">Tecapeek</td>
<td valign="top" align="center">-11.0</td>
<td valign="top" align="center">1.7</td>
</tr>
<tr>
<td valign="top" align="left">Teflon</td>
<td valign="top" align="center">-19.8</td>
<td valign="top" align="center">4.4</td>
</tr>
<tr>
<td valign="top" align="left">Titanium</td>
<td valign="top" align="center">-28.0</td>
<td valign="top" align="center">18.4</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>Experimental validation of the DEEDZ-MD method for determining mass density was performed using the tissue-equivalent inserts in the SC phantom, yielding a relative mean deviation of -1.4% compared to the vendor&#x2019;s provided mass density data (Gammex Electron Density CT Phantom 467, Gammex-RMI, Middleton, WI, USA).</p>
<p>For the SC phantom, the effect of lowering the tube current-time product on SPR prediction accuracy was also investigated. The tube current-time product was lowered from 300 mAs to 250 mAs and 200 mAs with no adverse effect on the SPR prediction accuracy and its standard deviation. Increasing the tube voltage from 120 kV<sub>p</sub> to 140 kV<sub>p</sub> while using a tube current-time product of 200 mAs resulted in approximately the same volume CT dose index (CTDI<sub>vol</sub>) as for the standard clinical protocol. DLCT-based SPR prediction using these CT acquisition settings (140 kV<sub>p</sub>/200 mAs) had a mean overall relative residual of 0.6%, which is equal to that of the 120 kV<sub>p</sub>/300 mAs protocol.</p>
</sec>
<sec id="s3_3">
<title>3.3 Treatment Planning and Dosimetric Validation With Anthropomorphic Head and Pelvic Phantoms</title>
<p>3D gamma analysis (3%/1.5 mm) using local calculation between SECT- and DLCT-based dose distributions and dosimetric measurements acquired with the OCTAVIUS<sup>&#xae;</sup> ionization chamber array using the anthropomorphic head phantom revealed substantial agreement between measured and calculated dose distributions (<xref ref-type="table" rid="T4">
<bold>Tables&#xa0;4</bold>
</xref>, <xref ref-type="table" rid="T5">
<bold>5</bold>
</xref>). For all three ion types, DLCT-based dose distributions showed higher 3D gamma passing rates compared to SECT-based dose distributions.</p>
<table-wrap id="T4" position="float">
<label>Table&#xa0;4</label>
<caption>
<p>3D gamma passing rates (3%/1.5 mm) using local calculation between SECT- and DLCT-based dose distributions and dosimetric measurements acquired with the OCTAVIUS<sup>&#xae;</sup> ionization chamber array using the anthropomorphic head phantom.</p>
</caption>
<table frame="hsides">
<thead>
<tr>
<th valign="top" colspan="9" align="left">3D gamma passing rate in %</th>
</tr>
<tr>
<th valign="top" colspan="3" align="center">
<sup>1</sup>H</th>
<th valign="top" colspan="3" align="center">
<sup>4</sup>He</th>
<th valign="top" colspan="3" align="center">
<sup>12</sup>C</th>
</tr>
<tr>
<th valign="top" align="left">Measurement position</th>
<th valign="top" align="center">SECT</th>
<th valign="top" align="center">DLCT</th>
<th valign="top" align="center">Measurement position</th>
<th valign="top" align="center">SECT</th>
<th valign="top" align="center">DLCT</th>
<th valign="top" align="center">Measurement position</th>
<th valign="top" align="center">SECT</th>
<th valign="top" align="center">DLCT</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">High-dose area, position A</td>
<td valign="top" align="center">98.6</td>
<td valign="top" align="center">98.8</td>
<td valign="top" align="left">High-dose area, position A</td>
<td valign="top" align="center">97.8</td>
<td valign="top" align="center">97.9</td>
<td valign="top" align="left">High-dose area, position A</td>
<td valign="top" align="center">96.9</td>
<td valign="top" align="center">97.0</td>
</tr>
<tr>
<td valign="top" align="left">High-dose area, position B</td>
<td valign="top" align="center">95.8</td>
<td valign="top" align="center">97.7</td>
<td valign="top" align="left">High-dose area, position B</td>
<td valign="top" align="center">95.7</td>
<td valign="top" align="center">99.4</td>
<td valign="top" align="left">92% dose fall-off</td>
<td valign="top" align="center">88.9</td>
<td valign="top" align="center">97.0</td>
</tr>
<tr>
<td valign="top" align="left">87% dose fall-off</td>
<td valign="top" align="center">92.3</td>
<td valign="top" align="center">99.6</td>
<td valign="top" align="left">72% dose fall-off</td>
<td valign="top" align="center">87.7</td>
<td valign="top" align="center">94.8</td>
<td valign="top" align="left">70% dose fall-off</td>
<td valign="top" align="center">75.7</td>
<td valign="top" align="center">78.3</td>
</tr>
<tr>
<td valign="top" align="left">72% dose fall-off</td>
<td valign="top" align="center">93.5</td>
<td valign="top" align="center">97.4</td>
<td valign="top" align="left">55% dose fall-off</td>
<td valign="top" align="center">81.5</td>
<td valign="top" align="center">84.6</td>
<td valign="top" align="left">53% dose fall-off</td>
<td valign="top" align="center">80.4</td>
<td valign="top" align="center">86.5</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn>
<p>Four different depths were investigated, with two of the depths for <sup>1</sup>H and <sup>4</sup>He being in the high-dose area (positions A and B), while the second depth for <sup>12</sup>C was already in the dose fall-off.</p>
</fn>
</table-wrap-foot>
</table-wrap>
<table-wrap id="T5" position="float">
<label>Table&#xa0;5</label>
<caption>
<p>3D gamma passing rates (3%/1.5 mm) using local calculation between SECT- and DLCT-based dose distributions and dosimetric measurements acquired with the OCTAVIUS<sup>&#xae;</sup> ionization chamber array using the anthropomorphic pelvic phantom.</p>
</caption>
<table frame="hsides">
<thead>
<tr>
<th valign="top" colspan="9" align="left">3D gamma passing rate in %</th>
</tr>
<tr>
<th valign="top" colspan="3" align="center">
<sup>1</sup>H</th>
<th valign="top" colspan="3" align="center">
<sup>4</sup>He</th>
<th valign="top" colspan="3" align="center">
<sup>12</sup>C</th>
</tr>
<tr>
<th valign="top" align="left">Measurement position</th>
<th valign="top" align="center">SECT</th>
<th valign="top" align="center">DLCT</th>
<th valign="top" align="left">Measurement position</th>
<th valign="top" align="center">SECT</th>
<th valign="top" align="center">DLCT</th>
<th valign="top" align="left">Measurement position</th>
<th valign="top" align="center">SECT</th>
<th valign="top" align="center">DLCT</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">High-dose area (prostate-like geometry)</td>
<td valign="top" align="center">97.2</td>
<td valign="top" align="center">99.3</td>
<td valign="top" align="left">High-dose area (prostate-like geometry)</td>
<td valign="top" align="center">99.4</td>
<td valign="top" align="center">99.4</td>
<td valign="top" align="left">High-dose area (prostate-like geometry)</td>
<td valign="top" align="center">99.3</td>
<td valign="top" align="center">99.5</td>
</tr>
<tr>
<td valign="top" align="left">High-dose area, position A (cubic target volume)</td>
<td valign="top" align="center">95.7</td>
<td valign="top" align="center">98.1</td>
<td valign="top" align="left">High-dose area, position A (cubic target volume)</td>
<td valign="top" align="center">99.4</td>
<td valign="top" align="center">99.4</td>
<td valign="top" align="left">High-dose area, position A (cubic target volume)</td>
<td valign="top" align="center">93.3</td>
<td valign="top" align="center">93.7</td>
</tr>
<tr>
<td valign="top" align="left">95% dose fall-off (cubic target volume)</td>
<td valign="top" align="center">81.8</td>
<td valign="top" align="center">100.0</td>
<td valign="top" align="left">95% dose fall-off (cubic target volume)</td>
<td valign="top" align="center">83.2</td>
<td valign="top" align="center">94.3</td>
<td valign="top" align="left">High-dose area, position B (cubic target volume)</td>
<td valign="top" align="center">92.6</td>
<td valign="top" align="center">98.1</td>
</tr>
<tr>
<td valign="top" align="left">83% dose fall-off (cubic target volume)</td>
<td valign="top" align="center">85.9</td>
<td valign="top" align="center">100.0</td>
<td valign="top" align="left">81% dose fall-off (cubic target volume)</td>
<td valign="top" align="center">83.0</td>
<td valign="top" align="center">92.0</td>
<td valign="top" align="left">94% dose fall-off (cubic target volume)</td>
<td valign="top" align="center">94.8</td>
<td valign="top" align="center">97.9</td>
</tr>
<tr>
<td valign="top" align="left">64% dose fall-off (cubic target volume)</td>
<td valign="top" align="center">86.9</td>
<td valign="top" align="center">99.9</td>
<td valign="top" align="left">63% dose fall-off (cubic target volume)</td>
<td valign="top" align="center">82.0</td>
<td valign="top" align="center">91.1</td>
<td valign="top" align="left">80% dose fall-off (cubic target volume)</td>
<td valign="top" align="center">96.7</td>
<td valign="top" align="center">97.6</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn>
<p>For the cubic target volume, four different depths were investigated, with two of the depths for <sup>12</sup>C being in the high-dose area (positions A and B), while the second depth for <sup>1</sup>H and <sup>4</sup>He was already in the dose fall-off.</p>
</fn>
</table-wrap-foot>
</table-wrap>
<p>For the head phantom, the 3D gamma passing rates (3%/1.5 mm) were 98.8% (<sup>1</sup>H), 97.9% (<sup>4</sup>He), and 97.0% (<sup>12</sup>C) using DLCT for the high-dose area of the target volume. For DLCT, the measured distal position of the 72% (<sup>1</sup>H)/55% (<sup>4</sup>He)/53% (<sup>12</sup>C) dose level of the target volume was within 1 mm of the predicted distal position of the respective dose level with 3D gamma passing rates (3%/1.5 mm) of 97.4% (<sup>1</sup>H), 84.6% (<sup>4</sup>He), and 86.5% (<sup>12</sup>C) (<xref ref-type="table" rid="T4">
<bold>Table&#xa0;4</bold>
</xref>).</p>
<p>For the pelvic phantom, the 3D gamma passing rates (3%/1.5 mm) were 99.3% (<sup>1</sup>H), 99.4% (<sup>4</sup>He), and 99.5% (<sup>12</sup>C) using DLCT for the high-dose area of the prostate-like geometry and 98.1% (<sup>1</sup>H), 99.4% (<sup>4</sup>He), and 93.7% (<sup>12</sup>C) for the high-dose area of the cubic target volume. For DLCT, the measured distal position of the 64% (<sup>1</sup>H)/63% (<sup>4</sup>He)/80% (<sup>12</sup>C) dose level of the cubic target volume was within 1 mm of the predicted distal position of the respective dose level with 3D gamma passing rates (3%/1.5 mm) of 99.9% (<sup>1</sup>H), 91.1% (<sup>4</sup>He), and 97.6% (<sup>12</sup>C) (<xref ref-type="table" rid="T5">
<bold>Table&#xa0;5</bold>
</xref>).</p>
</sec>
</sec>
<sec id="s4" sec-type="discussion">
<title>4 Discussion</title>
<sec id="s4_1">
<title>4.1 Key Findings</title>
<p>In this study, we performed a thorough analysis of the use of the Philips Spectral CT 7500 DLCT system for SPR prediction in particle therapy treatment planning. For this purpose, we experimentally verified DLCT-based SPR prediction accuracy and its impact on dose calculation in particle therapy planning with a Spectral CT 7500 scanner using tissue surrogates and non-tissue implant materials as well as anthropomorphic head and pelvic phantoms. To our knowledge, this is the first study to investigate this second-generation DLCT system for application in particle therapy. Moreover, this study presents the first dosimetric validation of DECT-based dose prediction using anthropomorphic phantoms for helium and carbon ion treatment plans. It is important to investigate DECT-based SPR prediction for helium and carbon ions since the impact of range uncertainty for these ion beams may lead to sizeable biological dose deviation, given the sharp gradients of linear energy transfer (LET) and relative biological effectiveness (RBE) end-of-range (<xref ref-type="bibr" rid="B38">38</xref>).</p>
<p>For tissue-equivalent materials, DLCT exhibited greater SPR prediction power, in general, compared to SECT with mean overall relative residuals of 0.6&#x2013;0.7% for DLCT-based predictions and 1.5&#x2013;1.8% for SECT-based predictions (<xref ref-type="fig" rid="f3">
<bold>Figure&#xa0;3</bold>
</xref>; <xref ref-type="table" rid="T1">
<bold>Tables&#xa0;1</bold>
</xref>, <xref ref-type="table" rid="T2">
<bold>2</bold>
</xref>). Ranges represent the variability introduced by four different phantom geometries. Furthermore, there are individual differences in the tissue-equivalent inserts, as discussed in Faller et&#xa0;al. (<xref ref-type="bibr" rid="B22">22</xref>). The larger residuals of SECT-based SPR predictions for certain tissue-equivalent inserts (i.e., bone mineral, brain, and inner bone substitutes) (<xref ref-type="fig" rid="f3">
<bold>Figure&#xa0;3</bold>
</xref>) may in part result from differences between the elemental composition of the tissue surrogate inserts and their real tissue counterparts (<xref ref-type="bibr" rid="B39">39</xref>).</p>
<p>In clinical practice, many complicating factors to straight-forward SPR prediction exist, such as the presence of artifact-inducing implants in patients. Therefore, we also validated the use of DLCT for SPR prediction in eight common non-tissue implant materials. DLCT again outperformed SECT, although relative residuals for both approaches were significantly greater than those for tissue-equivalent materials: 1.0&#x2013;18.4% for DLCT-based predictions, and -6.7%&#x2013;45.0% for SECT-based predictions (<xref ref-type="table" rid="T3">
<bold>Table&#xa0;3</bold>
</xref>). To illustrate the importance of SPR prediction for non-tissue implant materials, we consider the example of PALACOS<sup>&#xae;</sup> R + G bone cement. This common component of artificial joints is made mostly of PMMA and zirconium dioxide. Despite the presence of zirconium dioxide, a high-atomic-number material, the SPR of PALACOS<sup>&#xae;</sup> R + G is relatively low. The resulting uncertainty in SPR prediction can lead to a particle range deviation of several millimeters when using SECT-based treatment planning. Even if DECT is not implemented for quantitative SPR prediction in clinical practice, spectral image data could still be used to better differentiate between normal tissues and non-tissue implant materials and to help identify properties relating to the stopping power of non-tissue implant materials for contouring and SPR override. For example, using known ED and EAN data sets of commonly used implant materials, comparisons can be performed to quantify relevant physical properties to predict stopping power for unknown materials.</p>
<p>Furthermore, we used the Philips Spectral CT 7500 to experimentally validate the DEEDZ-MD method for determining mass density proposed by Saito (<xref ref-type="bibr" rid="B34">34</xref>). Our results showed a mean deviation of -1.4% from the reference value, which is similar to the -1.34% deviation reported by Saito (<xref ref-type="bibr" rid="B34">34</xref>). Future work may be dedicated to exploring treatment planning possibilities using mass density data.</p>
<p>We also found a result which suggests that tube current-time product can be lowered by 100 mAs in a simple geometric PMMA phantom without adverse effects on SPR prediction accuracy. Minimizing CT acquisition dose is an important component of CT research, particularly in fields with large pediatric contingents, such as particle therapy.</p>
<p>Finally, we demonstrated the feasibility of using the Philips Spectral CT 7500 to improve particle range prediction by irradiating anthropomorphic head and pelvic phantoms. We showed that dose distributions of DLCT-based treatment plans showed greater agreement with ionization chamber-measured dose distributions than dose distributions of SECT-based treatment plans for proton, helium ion, and carbon ion beams (<xref ref-type="table" rid="T4">
<bold>Tables&#xa0;4</bold>
</xref>, <xref ref-type="table" rid="T5">
<bold>5</bold>
</xref>).</p>
</sec>
<sec id="s4_2">
<title>4.2 Comparison to Previous Work</title>
<p>DLCT-based SPR prediction accuracy was previously investigated at HIT using many of the same phantoms and tissue-equivalent inserts as in this study, but with the Philips IQon Spectral CT (<xref ref-type="bibr" rid="B22">22</xref>) (<xref ref-type="supplementary-material" rid="SM1">
<bold>Supplementary Table&#xa0;2</bold>
</xref>). DLCT-based SPR prediction in that study yielded mean overall relative residuals of 0.6&#x2013;0.9%, compared to the 0.6&#x2013;0.7% reported here. These results indicate that the SPR prediction accuracy of the Philips Spectral CT 7500 is on par with that of the Philips IQon Spectral CT. However, the Philips Spectral CT 7500 provides numerous other advantages over the Philips IQon Spectral CT (<xref ref-type="supplementary-material" rid="SM1">
<bold>Supplementary Table&#xa0;3</bold>
</xref>).</p>
<p>A related study using the Philips IQon Spectral CT reported similar SPR prediction accuracy results using mono-energetic images and the same inserts for calibration and evaluation (RMSE=0.6%) (<xref ref-type="bibr" rid="B25">25</xref>). Moreover, DLCT-based SPR prediction in this study showed similar accuracy compared to other DECT systems for SPR prediction (<xref ref-type="bibr" rid="B12">12</xref>&#x2013;<xref ref-type="bibr" rid="B14">14</xref>, <xref ref-type="bibr" rid="B40">40</xref>). The SPR values of certain non-tissue implant materials used in this work have been previously investigated using dual-source CT (<xref ref-type="bibr" rid="B14">14</xref>). The DLCT functionality of the Philips Spectral CT 7500 yielded a similar SPR prediction accuracy as the dual-source CT in this previous study.</p>
</sec>
<sec id="s4_3">
<title>4.3 Clinical Relevance</title>
<p>As CT technology continues to improve, scanners with DECT capabilities are becoming increasingly available&#x2014;they are already used for diagnostic purposes at many healthcare facilities. The application of DECT to particle therapy treatment planning could potentially improve patient outcomes. For example, inaccuracies in SPR prediction for pediatric proton therapy planning arising from SECT calibration curves based on adult male tissues may be avoided with DECT (<xref ref-type="bibr" rid="B41">41</xref>). Furthermore, SECT-based SPR prediction has been shown to introduce large inter-center variations in SPR, reaching up to 9% between different European institutions (<xref ref-type="bibr" rid="B42">42</xref>). Thus, DECT-based SPR prediction might offer more consistent SPR predictions between treatment centers or allow new particle therapy centers to begin treatment with greater confidence in SPR prediction. Moreover, recent work has demonstrated the benefits of even small reductions in range uncertainty to normal tissue complication probability (<xref ref-type="bibr" rid="B43">43</xref>), supporting that even small improvements in SPR prediction may be clinically beneficial.</p>
</sec>
<sec id="s4_4">
<title>4.4 Study Limitations and Future Work</title>
<p>This study demonstrated the feasibility of direct, patient-specific SPR prediction using existing clinical equipment and frameworks. However, in order to use DLCT for SPR prediction beyond a defined research environment, it will be necessary to devise and implement a complete workflow of certified medical products which does not currently exist. To start, SPR DICOM files could be provided as an on-demand spectral result directly from the Philips Spectral CT 7500 scanner instead of needing additional calculation steps using ED and EAN data.</p>
<p>The strengths and limitations of the different DECT or spectral CT acquisition techniques currently available have been described in previous works (<xref ref-type="bibr" rid="B7">7</xref>, <xref ref-type="bibr" rid="B44">44</xref>&#x2013;<xref ref-type="bibr" rid="B46">46</xref>) and are summarized in <xref ref-type="supplementary-material" rid="SM1">
<bold>Supplementary Table&#xa0;1</bold>
</xref>, with a focus on applications to particle therapy treatment planning. Additionally, <xref ref-type="supplementary-material" rid="SM1">
<bold>Supplementary Table&#xa0;2</bold>
</xref> lists selected publications on the different DECT or spectral CT acquisition techniques to provide an overview of the current state of research. The optimal DECT acquisition technique and hardware choice depends on the purpose of the application (e.g., body site, presence of motion) and the relative effect of various parameters (e.g., spectral separation, impact of scattering, tube current modulation) (<xref ref-type="bibr" rid="B7">7</xref>), which makes it difficult to give a general recommendation. Imaging with a dual-layer detector enables perfectly temporally and spatially aligned data sets. Moreover, DLCT imaging allows for tube current modulation, a full scan field-of-view coverage, and requires no special mode for DECT acquisition. The dual-layer detector design also enables acquisition of dual-energy data at exactly the same phase of contrast enhancement. Furthermore, the DLCT technique facilitates projection-based material decomposition, allowing for better noise reduction and therefore potentially better material decomposition as compared to image-based methods (<xref ref-type="bibr" rid="B47">47</xref>). Nevertheless, spectral separation of DLCT systems is lower than that of source-based DECT systems (<xref ref-type="bibr" rid="B44">44</xref>), and spectral signal-to-noise ratio is comparable to that of other commercial DECT systems (<xref ref-type="bibr" rid="B48">48</xref>). In addition, DLCT systems carry the risk of cross-scatter occurring between detector layers (<xref ref-type="bibr" rid="B45">45</xref>).</p>
<p>In the future, particle CT might have the potential to further improve SPR prediction accuracies and serve as a ground-truth when comparing DECT-based SPR predictions (<xref ref-type="bibr" rid="B49">49</xref>). Thus far, precise SPR measurements using proton CT or helium CT are challenging to achieve, and provide a slightly lower SPR prediction accuracy compared to DECT (<xref ref-type="bibr" rid="B50">50</xref>).</p>
<p>While the tissue-equivalent materials used in this study are considered valid surrogates for biological tissues, they cannot fully represent the heterogeneity and variable composition of real tissues. Before DLCT-based SPR prediction can be implemented in clinical practice, more studies on biological tissue samples and <italic>in vivo</italic> systems need to be performed. In addition, measurements in this study were only performed with a male pelvic phantom, introducing a gender data gap. It would be desirable to perform similar measurements with a female pelvic phantom, but at the present time such a phantom does not exist. Furthermore, 4D treatment planning is important for radiotherapy treatments which require motion mitigation and/or consideration during treatment, such as the thorax and the abdominal region. Future work could implement 4D DLCT-based SPR prediction and treatment planning. The large coverage of the Philips Spectral CT 7500 compared to the Philips IQon Spectral CT (80 mm versus 40 mm) (<xref ref-type="supplementary-material" rid="SM1">
<bold>Supplementary Table&#xa0;3</bold>
</xref>) means that a larger portion of the patient anatomy is covered per gantry rotation of the CT system, leading to potential reduction in motion artifacts. Combining this feature with DLCT-based SPR prediction may enhance 4D CT planning in particle therapy for moving targets.</p>
<p>Finally, other beneficial characteristics of DECT should be investigated for all technical implementations available, including DLCT, to understand the full advantages of the technology. Beyond the computational aspects of DECT-based treatment planning discussed in this work, DECT imaging is expected to provide various opportunities to improve the accuracy of multiple parts of the radiotherapy chain. DECT has been suggested to improve image quality and reduce metal artifacts (<xref ref-type="bibr" rid="B51">51</xref>), to improve tumor staging, delineation, and characterization (<xref ref-type="bibr" rid="B52">52</xref>, <xref ref-type="bibr" rid="B53">53</xref>), and to contribute to improved normal tissue characterization and personalized treatment through physiological quantification (<xref ref-type="bibr" rid="B46">46</xref>). Furthermore, DECT also shows potential for improved dose calculations for treatment modalities other than particle therapy, such as brachytherapy and conventional photon-based teletherapy (<xref ref-type="bibr" rid="B51">51</xref>). Finally, as briefly explored in this study and proposed by Albrecht et&#xa0;al. (<xref ref-type="bibr" rid="B54">54</xref>), DECT has the potential to reduce total imaging dose. Future work might investigate these varied applications of DECT to radiotherapy.</p>
</sec>
</sec>
<sec id="s5" sec-type="data-availability">
<title>Data Availability Statement</title>
<p>The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.</p>
</sec>
<sec id="s6" sec-type="author-contributions">
<title>Author Contributions</title>
<p>Conceptualization, FL, AK, AM, and WS. Methodology, FL, AK, AM, and WS. Data acquisition and analysis, FL, AK, and BA. Interpretation, FL, AK, SM, TT, AM, and WS. Writing&#x2014;original draft preparation, FL and AK. Writing&#x2014;review and editing, FL, AK, SM, TT, BA, JD, AM, and WS. Supervision, JD, AM, and WS. All authors contributed to the article and approved the submitted version.</p>
</sec>
<sec id="s7" sec-type="funding-information">
<title>Funding</title>
<p>For the publication fee we acknowledge financial support by Deutsche Forschungsgemeinschaft within the funding programme "Open Access Publikationskosten" as well as by Heidelberg University.</p>
</sec>
<sec id="s8" sec-type="COI-statement">
<title>Conflict of Interest</title>
<p>WS is a member of the CT Advisory Board of Philips Medical Systems.</p>
<p>The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec id="s9" sec-type="disclaimer">
<title>Publisher&#x2019;s Note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
</body>
<back>
<sec id="s10" sec-type="supplementary-material">
<title>Supplementary Material</title>
<p>The Supplementary Material for this article can be found online at: <ext-link ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/fonc.2022.853495/full#supplementary-material">https://www.frontiersin.org/articles/10.3389/fonc.2022.853495/full#supplementary-material</ext-link></p>
<supplementary-material xlink:href="DataSheet_1.pdf" id="SM1" mimetype="application/pdf"/>
</sec>
<ref-list>
<title>References</title>
<ref id="B1">
<label>1</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Durante</surname> <given-names>M</given-names>
</name>
<name>
<surname>Orecchia</surname> <given-names>R</given-names>
</name>
<name>
<surname>Loeffler</surname> <given-names>J</given-names>
</name>
</person-group>. <article-title>Charged-Particle Therapy in Cancer: Clinical Uses and Future Perspectives</article-title>. <source>Nat Rev Clin Oncol</source> (<year>2017</year>) <volume>14</volume>:<page-range>483&#x2013;95</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1038/nrclinonc.2017.30</pub-id>
</citation>
</ref>
<ref id="B2">
<label>2</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bragg</surname> <given-names>WH</given-names>
</name>
<name>
<surname>Kleeman</surname> <given-names>R</given-names>
</name>
</person-group>. <article-title>On the Ionization Curves of Radium</article-title>. <source>London Edinburgh Dublin Philos Mag J Sci</source> (<year>1904</year>) <volume>8</volume>(<issue>48</issue>):<page-range>726&#x2013;38</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1080/14786440409463246</pub-id>
</citation>
</ref>
<ref id="B3">
<label>3</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Paganetti</surname> <given-names>H</given-names>
</name>
</person-group>. <article-title>Range Uncertainties in Proton Therapy and the Role of Monte Carlo Simulations</article-title>. <source>Phys Med Biol</source> (<year>2012</year>) <volume>57</volume>(<issue>11</issue>):<fpage>R99</fpage>&#x2013;<lpage>R117</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1088/0031-9155/57/11/R99</pub-id>
</citation>
</ref>
<ref id="B4">
<label>4</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yang</surname> <given-names>M</given-names>
</name>
<name>
<surname>Zhu</surname> <given-names>XR</given-names>
</name>
<name>
<surname>Park</surname> <given-names>PC</given-names>
</name>
<name>
<surname>Titt</surname> <given-names>U</given-names>
</name>
<name>
<surname>Mohan</surname> <given-names>R</given-names>
</name>
<name>
<surname>Virshup</surname> <given-names>G</given-names>
</name>
<etal/>
</person-group>. <article-title>Comprehensive Analysis of Proton Range Uncertainties Related to Patient Stopping-Power-Ratio Estimation Using the Stoichiometric Calibration</article-title>. <source>Phys Med Biol</source> (<year>2012</year>) <volume>57</volume>(<issue>13</issue>):<page-range>4095&#x2013;115</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1088/0031-9155/57/13/4095</pub-id>
</citation>
</ref>
<ref id="B5">
<label>5</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>B&#xe4;r</surname> <given-names>E</given-names>
</name>
<name>
<surname>Lalonde</surname> <given-names>A</given-names>
</name>
<name>
<surname>Royle</surname> <given-names>G</given-names>
</name>
<name>
<surname>Lu</surname> <given-names>H-M</given-names>
</name>
<name>
<surname>Bouchard</surname> <given-names>H</given-names>
</name>
</person-group>. <article-title>The Potential of Dual-Energy CT to Reduce Proton Beam Range Uncertainties</article-title>. <source>Med Phys</source> (<year>2017</year>) <volume>44</volume>(<issue>6</issue>):<page-range>2332&#x2013;44</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/mp.12215</pub-id>
</citation>
</ref>
<ref id="B6">
<label>6</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wohlfahrt</surname> <given-names>P</given-names>
</name>
<name>
<surname>M&#xf6;hler</surname> <given-names>C</given-names>
</name>
<name>
<surname>St&#xfc;tzer</surname> <given-names>K</given-names>
</name>
<name>
<surname>Greilich</surname> <given-names>S</given-names>
</name>
<name>
<surname>Richter</surname> <given-names>C</given-names>
</name>
</person-group>. <article-title>Dual-Energy CT Based Proton Range Prediction in Head and Pelvic Tumor Patients</article-title>. <source>Radiother Oncol</source> (<year>2017</year>) <volume>125</volume>(<issue>3</issue>):<page-range>526&#x2013;33</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.radonc.2017.09.042</pub-id>
</citation>
</ref>
<ref id="B7">
<label>7</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wohlfahrt</surname> <given-names>P</given-names>
</name>
<name>
<surname>Richter</surname> <given-names>C</given-names>
</name>
</person-group>. <article-title>Status and Innovations in Pre-Treatment CT Imaging for Proton Therapy</article-title>. <source>Br J Radiol</source> (<year>2020</year>) <volume>93</volume>:<elocation-id>20190590</elocation-id>. doi:&#xa0;<pub-id pub-id-type="doi">10.1259/bjr.20190590</pub-id>
</citation>
</ref>
<ref id="B8">
<label>8</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wohlfahrt</surname> <given-names>P</given-names>
</name>
<name>
<surname>M&#xf6;hler</surname> <given-names>C</given-names>
</name>
<name>
<surname>Troost</surname> <given-names>EGC</given-names>
</name>
<name>
<surname>Greilich</surname> <given-names>S</given-names>
</name>
<name>
<surname>Richter</surname> <given-names>C</given-names>
</name>
</person-group>. <article-title>Dual-Energy Computed Tomography to Assess Intra- and Inter-Patient Tissue Variability for Proton Treatment Planning of Patients With Brain Tumor</article-title>. <source>Int J Radiat Oncol Biol Phys</source> (<year>2019</year>) <volume>105</volume>(<issue>3</issue>):<page-range>504&#x2013;13</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.ijrobp.2019.06.2529</pub-id>
</citation>
</ref>
<ref id="B9">
<label>9</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Flohr</surname> <given-names>TG</given-names>
</name>
<name>
<surname>McCollough</surname> <given-names>CH</given-names>
</name>
<name>
<surname>Bruder</surname> <given-names>H</given-names>
</name>
<name>
<surname>Petersilka</surname> <given-names>M</given-names>
</name>
<name>
<surname>Gruber</surname> <given-names>K</given-names>
</name>
<name>
<surname>S&#xfc;&#xdf;</surname> <given-names>C</given-names>
</name>
<etal/>
</person-group>. <article-title>First Performance Evaluation of a Dual-Source CT (DSCT) System</article-title>. <source>Eur Radiol</source> (<year>2006</year>) <volume>16</volume>(<issue>2</issue>):<page-range>256&#x2013;68</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1007/s00330-005-2919-2</pub-id>
</citation>
</ref>
<ref id="B10">
<label>10</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yang</surname> <given-names>M</given-names>
</name>
<name>
<surname>Virshup</surname> <given-names>G</given-names>
</name>
<name>
<surname>Clayton</surname> <given-names>J</given-names>
</name>
<name>
<surname>Zhu</surname> <given-names>XR</given-names>
</name>
<name>
<surname>Mohan</surname> <given-names>R</given-names>
</name>
<name>
<surname>Dong</surname> <given-names>L</given-names>
</name>
</person-group>. <article-title>Theoretical Variance Analysis of Single- and Dual-Energy Computed Tomography Methods for Calculating Proton Stopping Power Ratios of Biological Tissues</article-title>. <source>Phys Med Biol</source> (<year>2010</year>) <volume>55</volume>(<issue>5</issue>):<page-range>1343&#x2013;62</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1088/0031-9155/55/5/006</pub-id>
</citation>
</ref>
<ref id="B11">
<label>11</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Schneider</surname> <given-names>U</given-names>
</name>
<name>
<surname>Pedroni</surname> <given-names>E</given-names>
</name>
<name>
<surname>Lomax</surname> <given-names>A</given-names>
</name>
</person-group>. <article-title>The Calibration of CT Hounsfield Units for Radiotherapy Treatment Planning</article-title>. <source>Phys Med Biol</source> (<year>1996</year>) <volume>41</volume>(<issue>1</issue>):<page-range>111&#x2013;24</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1088/0031-9155/41/1/009</pub-id>
</citation>
</ref>
<ref id="B12">
<label>12</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hansen</surname> <given-names>DC</given-names>
</name>
<name>
<surname>Seco</surname> <given-names>J</given-names>
</name>
<name>
<surname>S&#xf8;rensen</surname> <given-names>TS</given-names>
</name>
<name>
<surname>Petersen</surname> <given-names>JBB</given-names>
</name>
<name>
<surname>Wildberger</surname> <given-names>JE</given-names>
</name>
<name>
<surname>Verhaegen</surname> <given-names>F</given-names>
</name>
<etal/>
</person-group>. <article-title>A Simulation Study on Proton Computed Tomography (CT) Stopping Power Accuracy Using Dual Energy CT Scans as Benchmark</article-title>. <source>Acta Oncol</source> (<year>2015</year>) <volume>54</volume>(<issue>9</issue>):<page-range>1638&#x2013;42</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.3109/0284186X.2015.1061212</pub-id>
</citation>
</ref>
<ref id="B13">
<label>13</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hudobivnik</surname> <given-names>N</given-names>
</name>
<name>
<surname>Schwarz</surname> <given-names>F</given-names>
</name>
<name>
<surname>Johnson</surname> <given-names>T</given-names>
</name>
<name>
<surname>Agolli</surname> <given-names>L</given-names>
</name>
<name>
<surname>Dedes</surname> <given-names>G</given-names>
</name>
<name>
<surname>Tessonnier</surname> <given-names>T</given-names>
</name>
<etal/>
</person-group>. <article-title>Comparison of Proton Therapy Treatment Planning for Head Tumors With a Pencil Beam Algorithm on Dual and Single Energy CT Images</article-title>. <source>Med Phys</source> (<year>2016</year>) <volume>43</volume>(<issue>1</issue>):<fpage>495</fpage>&#x2013;<lpage>504</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1118/1.4939106</pub-id>
</citation>
</ref>
<ref id="B14">
<label>14</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>H&#xfc;nemohr</surname> <given-names>N</given-names>
</name>
<name>
<surname>Krauss</surname> <given-names>B</given-names>
</name>
<name>
<surname>Tremmel</surname> <given-names>C</given-names>
</name>
<name>
<surname>Ackermann</surname> <given-names>B</given-names>
</name>
<name>
<surname>J&#xe4;kel</surname> <given-names>O</given-names>
</name>
<name>
<surname>Greilich</surname> <given-names>S</given-names>
</name>
</person-group>. <article-title>Experimental Verification of Ion Stopping Power Prediction From Dual Energy CT Data in Tissue Surrogates</article-title>. <source>Phys Med Biol</source> (<year>2014</year>) <volume>59</volume>(<issue>1</issue>):<fpage>83</fpage>&#x2013;<lpage>96</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1088/0031-9155/59/1/83</pub-id>
</citation>
</ref>
<ref id="B15">
<label>15</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhu</surname> <given-names>J</given-names>
</name>
<name>
<surname>Penfold</surname> <given-names>SN</given-names>
</name>
</person-group>. <article-title>Dosimetric Comparison of Stopping Power Calibration With Dual-Energy CT and Single-Energy CT in Proton Therapy Treatment Planning</article-title>. <source>Med Phys</source> (<year>2016</year>) <volume>43</volume>(<issue>6</issue>):<page-range>2845&#x2013;54</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1118/1.4948683</pub-id>
</citation>
</ref>
<ref id="B16">
<label>16</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>B&#xe4;r</surname> <given-names>E</given-names>
</name>
<name>
<surname>Lalonde</surname> <given-names>A</given-names>
</name>
<name>
<surname>Zhang</surname> <given-names>R</given-names>
</name>
<name>
<surname>Jee</surname> <given-names>K-W</given-names>
</name>
<name>
<surname>Yang</surname> <given-names>K</given-names>
</name>
<name>
<surname>Sharp</surname> <given-names>G</given-names>
</name>
<etal/>
</person-group>. <article-title>Experimental Validation of Two Dual-Energy CT Methods for Proton Therapy Using Heterogeneous Tissue Samples</article-title>. <source>Med Phys</source> (<year>2018</year>) <volume>45</volume>(<issue>1</issue>):<fpage>48</fpage>&#x2013;<lpage>59</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/mp.12666</pub-id>
</citation>
</ref>
<ref id="B17">
<label>17</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>M&#xf6;hler</surname> <given-names>C</given-names>
</name>
<name>
<surname>Russ</surname> <given-names>T</given-names>
</name>
<name>
<surname>Wohlfahrt</surname> <given-names>P</given-names>
</name>
<name>
<surname>Elter</surname> <given-names>A</given-names>
</name>
<name>
<surname>Runz</surname> <given-names>A</given-names>
</name>
<name>
<surname>Richter</surname> <given-names>C</given-names>
</name>
<etal/>
</person-group>. <article-title>Experimental Verification of Stopping-Power Prediction From Single- and Dual-Energy Computed Tomography in Biological Tissues</article-title>. <source>Phys Med Biol</source> (<year>2018</year>) <volume>63</volume>(<issue>2</issue>):<fpage>025001</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1088/1361-6560/aaa1c9</pub-id>
</citation>
</ref>
<ref id="B18">
<label>18</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Taasti</surname> <given-names>VT</given-names>
</name>
<name>
<surname>Michalak</surname> <given-names>GJ</given-names>
</name>
<name>
<surname>Hansen</surname> <given-names>DC</given-names>
</name>
<name>
<surname>Deisher</surname> <given-names>AJ</given-names>
</name>
<name>
<surname>Kruse</surname> <given-names>JJ</given-names>
</name>
<name>
<surname>Krauss</surname> <given-names>B</given-names>
</name>
<etal/>
</person-group>. <article-title>Validation of Proton Stopping Power Ratio Estimation Based on Dual Energy CT Using Fresh Tissue Samples</article-title>. <source>Phys Med Biol</source> (<year>2018</year>) <volume>63</volume>(<issue>1</issue>):<fpage>015012</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1088/1361-6560/aa952f</pub-id>
</citation>
</ref>
<ref id="B19">
<label>19</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wohlfahrt</surname> <given-names>P</given-names>
</name>
<name>
<surname>M&#xf6;hler</surname> <given-names>C</given-names>
</name>
<name>
<surname>Richter</surname> <given-names>C</given-names>
</name>
<name>
<surname>Greilich</surname> <given-names>S</given-names>
</name>
</person-group>. <article-title>Evaluation of Stopping-Power Prediction by Dual- and Single-Energy Computed Tomography in an Anthropomorphic Ground-Truth Phantom</article-title>. <source>Int J Radiat Oncol Biol Phys</source> (<year>2018</year>) <volume>100</volume>(<issue>1</issue>):<page-range>244&#x2013;53</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.ijrobp.2017.09.025</pub-id>
</citation>
</ref>
<ref id="B20">
<label>20</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Xie</surname> <given-names>Y</given-names>
</name>
<name>
<surname>Ainsley</surname> <given-names>C</given-names>
</name>
<name>
<surname>Yin</surname> <given-names>L</given-names>
</name>
<name>
<surname>Zou</surname> <given-names>W</given-names>
</name>
<name>
<surname>McDonough</surname> <given-names>J</given-names>
</name>
<name>
<surname>Solberg</surname> <given-names>TD</given-names>
</name>
<etal/>
</person-group>. <article-title>
<italic>Ex Vivo</italic> Validation of a Stoichiometric Dual Energy CT Proton Stopping Power Ratio Calibration</article-title>. <source>Phys Med Biol</source> (<year>2018</year>) <volume>63</volume>(<issue>5</issue>):<fpage>055016</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1088/1361-6560/aaae91</pub-id>
</citation>
</ref>
<ref id="B21">
<label>21</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ates</surname> <given-names>O</given-names>
</name>
<name>
<surname>Hua</surname> <given-names>C</given-names>
</name>
<name>
<surname>Zhao</surname> <given-names>L</given-names>
</name>
<name>
<surname>Shapira</surname> <given-names>N</given-names>
</name>
<name>
<surname>Yagil</surname> <given-names>Y</given-names>
</name>
<name>
<surname>Merchant</surname> <given-names>TE</given-names>
</name>
<etal/>
</person-group>. <article-title>Feasibility of Using Post-Contrast Dual-Energy CT for Pediatric Radiation Treatment Planning and Dose Calculation</article-title>. <source>Br J Radiol</source> (<year>2020</year>) <volume>94</volume>(<issue>1118</issue>):<elocation-id>20200170</elocation-id>. doi:&#xa0;<pub-id pub-id-type="doi">10.1259/bjr.20200170</pub-id>
</citation>
</ref>
<ref id="B22">
<label>22</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Faller</surname> <given-names>FK</given-names>
</name>
<name>
<surname>Mein</surname> <given-names>S</given-names>
</name>
<name>
<surname>Ackermann</surname> <given-names>B</given-names>
</name>
<name>
<surname>Debus</surname> <given-names>J</given-names>
</name>
<name>
<surname>Stiller</surname> <given-names>W</given-names>
</name>
<name>
<surname>Mairani</surname> <given-names>A</given-names>
</name>
</person-group>. <article-title>Pre-Clinical Evaluation of Dual-Layer Spectral Computed Tomography-Based Stopping Power Prediction for Particle Therapy Planning at the Heidelberg Ion Beam Therapy Center</article-title>. <source>Phys Med Biol</source> (<year>2020</year>) <volume>65</volume>(<issue>9</issue>):<fpage>095007</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1088/1361-6560/ab735e</pub-id>
</citation>
</ref>
<ref id="B23">
<label>23</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gro&#xdf;e Hokamp</surname> <given-names>N</given-names>
</name>
<name>
<surname>Maintz</surname> <given-names>D</given-names>
</name>
<name>
<surname>Shapira</surname> <given-names>N</given-names>
</name>
<name>
<surname>Chang</surname> <given-names>DH</given-names>
</name>
<name>
<surname>No&#xeb;l</surname> <given-names>PB</given-names>
</name>
</person-group>. <article-title>Technical Background of a Novel Detector-Based Approach to Dual-Energy Computed Tomography</article-title>. <source>Diagn Interv Radiol</source> (<year>2020</year>) <volume>26</volume>(<issue>1</issue>):<fpage>68</fpage>&#x2013;<lpage>71</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.5152/dir.2019.19136</pub-id>
</citation>
</ref>
<ref id="B24">
<label>24</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hua</surname> <given-names>C</given-names>
</name>
<name>
<surname>Shapira</surname> <given-names>N</given-names>
</name>
<name>
<surname>Merchant</surname> <given-names>TE</given-names>
</name>
<name>
<surname>Klahr</surname> <given-names>P</given-names>
</name>
<name>
<surname>Yagil</surname> <given-names>Y</given-names>
</name>
</person-group>. <article-title>Accuracy of Electron Density, Effective Atomic Number, and Iodine Concentration Determination With a Dual-Layer Dual-Energy Computed Tomography System</article-title>. <source>Med Phys</source> (<year>2018</year>) <volume>45</volume>(<issue>6</issue>):<page-range>2486&#x2013;97</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/mp.12903</pub-id>
</citation>
</ref>
<ref id="B25">
<label>25</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Landry</surname> <given-names>G</given-names>
</name>
<name>
<surname>D&#xf6;rringer</surname> <given-names>F</given-names>
</name>
<name>
<surname>Si-Mohamed</surname> <given-names>S</given-names>
</name>
<name>
<surname>Douek</surname> <given-names>P</given-names>
</name>
<name>
<surname>Abascal</surname> <given-names>JFPJ</given-names>
</name>
<name>
<surname>Peyrin</surname> <given-names>F</given-names>
</name>
<etal/>
</person-group>. <article-title>Technical Note: Relative Proton Stopping Power Estimation From Virtual Monoenergetic Images Reconstructed From Dual-Layer Computed Tomography</article-title>. <source>Med Phys</source> (<year>2019</year>) <volume>46</volume>(<issue>4</issue>):<page-range>1821&#x2013;8</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/mp.13404</pub-id>
</citation>
</ref>
<ref id="B26">
<label>26</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Longarino</surname> <given-names>FK</given-names>
</name>
<name>
<surname>Tessonnier</surname> <given-names>T</given-names>
</name>
<name>
<surname>Mein</surname> <given-names>S</given-names>
</name>
<name>
<surname>Harrabi</surname> <given-names>SB</given-names>
</name>
<name>
<surname>Debus</surname> <given-names>J</given-names>
</name>
<name>
<surname>Stiller</surname> <given-names>W</given-names>
</name>
<etal/>
</person-group>. <article-title>Dual-Layer Spectral CT for Proton, Helium, and Carbon Ion Beam Therapy Planning of Brain Tumors</article-title>. <source>J Appl Clin Med Phys</source> (<year>2022</year>) <volume>23</volume>(<issue>1</issue>):<fpage>e13465</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/acm2.13465</pub-id>
</citation>
</ref>
<ref id="B27">
<label>27</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ohira</surname> <given-names>S</given-names>
</name>
<name>
<surname>Washio</surname> <given-names>H</given-names>
</name>
<name>
<surname>Yagi</surname> <given-names>M</given-names>
</name>
<name>
<surname>Karino</surname> <given-names>T</given-names>
</name>
<name>
<surname>Nakamura</surname> <given-names>K</given-names>
</name>
<name>
<surname>Ueda</surname> <given-names>Y</given-names>
</name>
<etal/>
</person-group>. <article-title>Estimation of Electron Density, Effective Atomic Number and Stopping Power Ratio Using Dual-Layer Computed Tomography for Radiotherapy Treatment Planning</article-title>. <source>Physica Med</source> (<year>2018</year>) <volume>56</volume>:<fpage>34</fpage>&#x2013;<lpage>40</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.ejmp.2018.11.008</pub-id>
</citation>
</ref>
<ref id="B28">
<label>28</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>B&#xe4;r</surname> <given-names>E</given-names>
</name>
<name>
<surname>Andreo</surname> <given-names>P</given-names>
</name>
<name>
<surname>Lalonde</surname> <given-names>A</given-names>
</name>
<name>
<surname>Royle</surname> <given-names>G</given-names>
</name>
<name>
<surname>Bouchard</surname> <given-names>H</given-names>
</name>
</person-group>. <article-title>Optimized <italic>I-</italic>Values for Use With the Bragg Additivity Rule and Their Impact on Proton Stopping Power and Range Uncertainty</article-title>. <source>Phys Med Biol</source> (<year>2018</year>) <volume>63</volume>(<issue>16</issue>):<fpage>165007</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1088/1361-6560/aad312</pub-id>
</citation>
</ref>
<ref id="B29">
<label>29</label>
<citation citation-type="journal">
<article-title>International Commission on Radiation Units and Measurements (ICRU). Report 90: Key Data for Ionizing-Radiation Dosimetry: Measurement Standards and Applications</article-title>. <source>J Int Comm Radiat Units Meas</source> (<year>2014</year>) <volume>14</volume>(<issue>1</issue>):<elocation-id>1&#x2013;110</elocation-id>. doi:&#xa0;<pub-id pub-id-type="doi">10.1093/jicru/ndw038</pub-id>
</citation>
</ref>
<ref id="B30">
<label>30</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Inaniwa</surname> <given-names>T</given-names>
</name>
<name>
<surname>Kanematsu</surname> <given-names>N</given-names>
</name>
</person-group>. <article-title>Effective Particle Energies for Stopping Power Calculation in Radiotherapy Treatment Planning With Protons and Helium, Carbon, and Oxygen Ions</article-title>. <source>Phys Med Biol</source> (<year>2016</year>) <volume>61</volume>(<issue>20</issue>):<page-range>N542&#x2013;50</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1088/0031-9155/61/20/N542</pub-id>
</citation>
</ref>
<ref id="B31">
<label>31</label>
<citation citation-type="journal">
<article-title>International Commission on Radiation Units and Measurements (ICRU). Report 93: Prescribing, Recording, and Reporting Light Ion Beam Therapy</article-title>. <source>J Int Comm Radiat Units Meas</source> (<year>2016</year>) <volume>16</volume>(<issue>2</issue>):<fpage>1</fpage>&#x2013;<lpage>211</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1093/jicru/ndy024</pub-id>
</citation>
</ref>
<ref id="B32">
<label>32</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Schneider</surname> <given-names>W</given-names>
</name>
<name>
<surname>Bortfeld</surname> <given-names>T</given-names>
</name>
<name>
<surname>Schlegel</surname> <given-names>W</given-names>
</name>
</person-group>. <article-title>Correlation Between CT Numbers and Tissue Parameters Needed for Monte Carlo Simulations of Clinical Dose Distributions</article-title>. <source>Phys Med Biol</source> (<year>2000</year>) <volume>45</volume>(<issue>2</issue>):<page-range>459&#x2013;78</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1088/0031-9155/45/2/314</pub-id>
</citation>
</ref>
<ref id="B33">
<label>33</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Telsemeyer</surname> <given-names>J</given-names>
</name>
<name>
<surname>Ackermann</surname> <given-names>B</given-names>
</name>
<name>
<surname>Ecker</surname> <given-names>S</given-names>
</name>
<name>
<surname>J&#xe4;kel</surname> <given-names>O</given-names>
</name>
<name>
<surname>Marti&#x161;&#xed;kov&#xe1;</surname> <given-names>M</given-names>
</name>
</person-group>. <article-title>Experimental Verification of Ion Range Calculation in a Treatment Planning System Using a Flat-Panel Detector</article-title>. <source>Phys Med Biol</source> (<year>2014</year>) <volume>59</volume>(<issue>14</issue>):<page-range>3737&#x2013;47</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1088/0031-9155/59/14/3737</pub-id>
</citation>
</ref>
<ref id="B34">
<label>34</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Saito</surname> <given-names>M</given-names>
</name>
</person-group>. <article-title>Quadratic Relation for Mass Density Calibration in Human Body Using Dual-Energy CT Data</article-title>. <source>Med Phys</source> (<year>2021</year>) <volume>48</volume>(<issue>6</issue>):<page-range>3065&#x2013;73</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/mp.14899</pub-id>
</citation>
</ref>
<ref id="B35">
<label>35</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Saito</surname> <given-names>M</given-names>
</name>
<name>
<surname>Sagara</surname> <given-names>S</given-names>
</name>
</person-group>. <article-title>Simplified Derivation of Stopping Power Ratio in the Human Body From Dual-Energy CT Data</article-title>. <source>Med Phys</source> (<year>2017</year>) <volume>44</volume>(<issue>8</issue>):<page-range>4179&#x2013;87</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/mp.12386</pub-id>
</citation>
</ref>
<ref id="B36">
<label>36</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mein</surname> <given-names>S</given-names>
</name>
<name>
<surname>Kopp</surname> <given-names>B</given-names>
</name>
<name>
<surname>Tessonnier</surname> <given-names>T</given-names>
</name>
<name>
<surname>Ackermann</surname> <given-names>B</given-names>
</name>
<name>
<surname>Ecker</surname> <given-names>S</given-names>
</name>
<name>
<surname>Bauer</surname> <given-names>J</given-names>
</name>
<etal/>
</person-group>. <article-title>Dosimetric Validation of Monte Carlo and Analytical Dose Engines With Raster-Scanning <sup>1</sup>H, <sup>4</sup>He, <sup>12</sup>C, and <sup>16</sup>O Ion-Beams Using an Anthropomorphic Phantom</article-title>. <source>Physica Med</source> (<year>2019</year>) <volume>64</volume>:<page-range>123&#x2013;31</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.ejmp.2019.07.001</pub-id>
</citation>
</ref>
<ref id="B37">
<label>37</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Low</surname> <given-names>DA</given-names>
</name>
<name>
<surname>Harms</surname> <given-names>WB</given-names>
</name>
<name>
<surname>Mutic</surname> <given-names>S</given-names>
</name>
<name>
<surname>Purdy</surname> <given-names>JA</given-names>
</name>
</person-group>. <article-title>A Technique for the Quantitative Evaluation of Dose Distributions</article-title>. <source>Med Phys</source> (<year>1998</year>) <volume>25</volume>(<issue>5</issue>):<page-range>656&#x2013;61</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1118/1.598248</pub-id>
</citation>
</ref>
<ref id="B38">
<label>38</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Park</surname> <given-names>SH</given-names>
</name>
<name>
<surname>Kang</surname> <given-names>JO</given-names>
</name>
</person-group>. <article-title>Basics of Particle Therapy I: Physics</article-title>. <source>Radiat Oncol J</source> (<year>2011</year>) <volume>29</volume>(<issue>3</issue>):<page-range>135&#x2013;46</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.3857/roj.2011.29.3.135</pub-id>
</citation>
</ref>
<ref id="B39">
<label>39</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gom&#xe0;</surname> <given-names>C</given-names>
</name>
<name>
<surname>Almeida</surname> <given-names>IP</given-names>
</name>
<name>
<surname>Verhaegen</surname> <given-names>F</given-names>
</name>
</person-group>. <article-title>Revisiting the Single-Energy CT Calibration for Proton Therapy Treatment Planning: A Critical Look at the Stoichiometric Method</article-title>. <source>Phys Med Biol</source> (<year>2018</year>) <volume>63</volume>(<issue>23</issue>):<fpage>235011</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1088/1361-6560/aaede5</pub-id>
</citation>
</ref>
<ref id="B40">
<label>40</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>M&#xf6;hler</surname> <given-names>C</given-names>
</name>
<name>
<surname>Wohlfahrt</surname> <given-names>P</given-names>
</name>
<name>
<surname>Richter</surname> <given-names>C</given-names>
</name>
<name>
<surname>Greilich</surname> <given-names>S</given-names>
</name>
</person-group>. <article-title>Range Prediction for Tissue Mixtures Based on Dual-Energy CT</article-title>. <source>Phys Med Biol</source> (<year>2016</year>) <volume>61</volume>(<issue>11</issue>):<page-range>N268&#x2013;75</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1088/0031-9155/61/11/N268</pub-id>
</citation>
</ref>
<ref id="B41">
<label>41</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>B&#xe4;r</surname> <given-names>E</given-names>
</name>
<name>
<surname>Collins-Fekete</surname> <given-names>C-A</given-names>
</name>
<name>
<surname>Rompokos</surname> <given-names>V</given-names>
</name>
<name>
<surname>Zhang</surname> <given-names>Y</given-names>
</name>
<name>
<surname>Gaze</surname> <given-names>MN</given-names>
</name>
<name>
<surname>Warry</surname> <given-names>A</given-names>
</name>
<etal/>
</person-group>. <article-title>Assessment of the Impact of CT Calibration Procedures for Proton Therapy Planning on Pediatric Treatments</article-title>. <source>Med Phys</source> (<year>2021</year>) <volume>48</volume>(<issue>9</issue>):<page-range>5202&#x2013;18</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/mp.15062</pub-id>
</citation>
</ref>
<ref id="B42">
<label>42</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Peters</surname> <given-names>N</given-names>
</name>
<name>
<surname>Wohlfahrt</surname> <given-names>P</given-names>
</name>
<name>
<surname>Dahlgren</surname> <given-names>CV</given-names>
</name>
<name>
<surname>de Marzi</surname> <given-names>L</given-names>
</name>
<name>
<surname>Ellerbrock</surname> <given-names>M</given-names>
</name>
<name>
<surname>Fracchiolla</surname> <given-names>F</given-names>
</name>
<etal/>
</person-group>. <article-title>Experimental Assessment of Inter-Centre Variation in Stopping-Power and Range Prediction in Particle Therapy</article-title>. <source>Radiother Oncol</source> (<year>2021</year>) <volume>163</volume>:<fpage>7</fpage>&#x2013;<lpage>13</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.radonc.2021.07.019</pub-id>
</citation>
</ref>
<ref id="B43">
<label>43</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tattenberg</surname> <given-names>S</given-names>
</name>
<name>
<surname>Madden</surname> <given-names>TM</given-names>
</name>
<name>
<surname>Gorissen</surname> <given-names>BL</given-names>
</name>
<name>
<surname>Bortfeld</surname> <given-names>T</given-names>
</name>
<name>
<surname>Parodi</surname> <given-names>K</given-names>
</name>
<name>
<surname>Verburg</surname> <given-names>J</given-names>
</name>
</person-group>. <article-title>Proton Range Uncertainty Reduction Benefits for Skull Base Tumors in Terms of Normal Tissue Complication Probability (NTCP) and Healthy Tissue Doses</article-title>. <source>Med Phys</source> (<year>2021</year>) <volume>48</volume>(<issue>9</issue>):<page-range>5356&#x2013;66</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/mp.15097</pub-id>
</citation>
</ref>
<ref id="B44">
<label>44</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>McCollough</surname> <given-names>CH</given-names>
</name>
<name>
<surname>Leng</surname> <given-names>S</given-names>
</name>
<name>
<surname>Yu</surname> <given-names>L</given-names>
</name>
<name>
<surname>Fletcher</surname> <given-names>JG</given-names>
</name>
</person-group>. <article-title>Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications</article-title>. <source>Radiology</source> (<year>2015</year>) <volume>276</volume>(<issue>3</issue>):<page-range>637&#x2013;53</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1148/radiol.2015142631</pub-id>
</citation>
</ref>
<ref id="B45">
<label>45</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>McCollough</surname> <given-names>CH</given-names>
</name>
<name>
<surname>Boedeker</surname> <given-names>K</given-names>
</name>
<name>
<surname>Cody</surname> <given-names>D</given-names>
</name>
<name>
<surname>Duan</surname> <given-names>X</given-names>
</name>
<name>
<surname>Flohr</surname> <given-names>T</given-names>
</name>
<name>
<surname>Halliburton</surname> <given-names>SS</given-names>
</name>
<etal/>
</person-group>. <article-title>Principles and Applications of Multienergy CT: Report of AAPM Task Group 291</article-title>. <source>Med Phys</source> (<year>2020</year>) <volume>47</volume>(<issue>7</issue>):<page-range>e881&#x2013;912</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/mp.14157</pub-id>
</citation>
</ref>
<ref id="B46">
<label>46</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kruis</surname> <given-names>MF</given-names>
</name>
</person-group>. <article-title>Improving Radiation Physics, Tumor Visualisation, and Treatment Quantification in Radiotherapy With Spectral or Dual-Energy CT</article-title>. <source>J Appl Clin Med Phys</source> (<year>2022</year>) <volume>23</volume>(<issue>1</issue>):<fpage>e13468</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/acm2.13468</pub-id>
</citation>
</ref>
<ref id="B47">
<label>47</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Maa&#xdf;</surname> <given-names>C</given-names>
</name>
<name>
<surname>Baer</surname> <given-names>M</given-names>
</name>
<name>
<surname>Kachelrie&#xdf;</surname> <given-names>M</given-names>
</name>
</person-group>. <article-title>Image-Based Dual Energy CT Using Optimized Precorrection Functions: A Practical New Approach of Material Decomposition in Image Domain</article-title>. <source>Med Phys</source> (<year>2009</year>) <volume>36</volume>(<issue>8</issue>):<page-range>3818&#x2013;29</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1118/1.3157235</pub-id>
</citation>
</ref>
<ref id="B48">
<label>48</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sellerer</surname> <given-names>T</given-names>
</name>
<name>
<surname>No&#xeb;l</surname> <given-names>PB</given-names>
</name>
<name>
<surname>Patino</surname> <given-names>M</given-names>
</name>
<name>
<surname>Parakh</surname> <given-names>A</given-names>
</name>
<name>
<surname>Ehn</surname> <given-names>S</given-names>
</name>
<name>
<surname>Zeiter</surname> <given-names>S</given-names>
</name>
<etal/>
</person-group>. <article-title>Dual-Energy CT: A Phantom Comparison of Different Platforms for Abdominal Imaging</article-title>. <source>Eur Radiol</source> (<year>2018</year>) <volume>28</volume>(<issue>7</issue>):<page-range>2745&#x2013;55</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1007/s00330-017-5238-5</pub-id>
</citation>
</ref>
<ref id="B49">
<label>49</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Dedes</surname> <given-names>G</given-names>
</name>
<name>
<surname>Dickmann</surname> <given-names>J</given-names>
</name>
<name>
<surname>Niepel</surname> <given-names>K</given-names>
</name>
<name>
<surname>Wesp</surname> <given-names>P</given-names>
</name>
<name>
<surname>Johnson</surname> <given-names>RP</given-names>
</name>
<name>
<surname>Pankuch</surname> <given-names>M</given-names>
</name>
<etal/>
</person-group>. <article-title>Experimental Comparison of Proton CT and Dual Energy X-Ray CT for Relative Stopping Power Estimation in Proton Therapy</article-title>. <source>Phys Med Biol</source> (<year>2019</year>) <volume>64</volume>(<issue>16</issue>):<fpage>165002</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1088/1361-6560/ab2b72</pub-id>
</citation>
</ref>
<ref id="B50">
<label>50</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>B&#xe4;r</surname> <given-names>E</given-names>
</name>
<name>
<surname>Volz</surname> <given-names>L</given-names>
</name>
<name>
<surname>Collins-Fekete</surname> <given-names>C-A</given-names>
</name>
<name>
<surname>Brons</surname> <given-names>S</given-names>
</name>
<name>
<surname>Runz</surname> <given-names>A</given-names>
</name>
<name>
<surname>Schulte</surname> <given-names>RW</given-names>
</name>
<etal/>
</person-group>. <article-title>Experimental Comparison of Photon Versus Particle Computed Tomography to Predict Tissue Relative Stopping Powers</article-title>. <source>Med Phys</source> (<year>2022</year>) <volume>49</volume>(<issue>1</issue>):<page-range>474&#x2013;87</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/mp.15283</pub-id>
</citation>
</ref>
<ref id="B51">
<label>51</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>van Elmpt</surname> <given-names>W</given-names>
</name>
<name>
<surname>Landry</surname> <given-names>G</given-names>
</name>
<name>
<surname>Das</surname> <given-names>M</given-names>
</name>
<name>
<surname>Verhaegen</surname> <given-names>F</given-names>
</name>
</person-group>. <article-title>Dual Energy CT in Radiotherapy: Current Applications and Future Outlook</article-title>. <source>Radiother Oncol</source> (<year>2016</year>) <volume>119</volume>(<issue>1</issue>):<page-range>137&#x2013;44</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.radonc.2016.02.026</pub-id>
</citation>
</ref>
<ref id="B52">
<label>52</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Toepker</surname> <given-names>M</given-names>
</name>
<name>
<surname>Czerny</surname> <given-names>C</given-names>
</name>
<name>
<surname>Ringl</surname> <given-names>H</given-names>
</name>
<name>
<surname>Fruehwald-Pallamar</surname> <given-names>J</given-names>
</name>
<name>
<surname>Wolf</surname> <given-names>F</given-names>
</name>
<name>
<surname>Weber</surname> <given-names>M</given-names>
</name>
<etal/>
</person-group>. <article-title>Can Dual-Energy CT Improve the Assessment of Tumor Margins in Oral Cancer</article-title>? <source>Oral Oncol</source> (<year>2014</year>) <volume>50</volume>(<issue>3</issue>):<page-range>221&#x2013;7</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.oraloncology.2013.12.001</pub-id>
</citation>
</ref>
<ref id="B53">
<label>53</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wichmann</surname> <given-names>JL</given-names>
</name>
<name>
<surname>N&#xf6;ske</surname> <given-names>EM</given-names>
</name>
<name>
<surname>Kraft</surname> <given-names>J</given-names>
</name>
<name>
<surname>Burck</surname> <given-names>I</given-names>
</name>
<name>
<surname>Wagenblast</surname> <given-names>J</given-names>
</name>
<name>
<surname>Eckardt</surname> <given-names>A</given-names>
</name>
<etal/>
</person-group>. <article-title>Virtual Monoenergetic Dual-Energy Computed Tomography: Optimization of Kiloelectron Volt Settings in Head and Neck Cancer</article-title>. <source>Invest Radiol</source> (<year>2014</year>) <volume>49</volume>(<issue>11</issue>):<page-range>735&#x2013;41</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1097/RLI.0000000000000077</pub-id>
</citation>
</ref>
<ref id="B54">
<label>54</label>
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Albrecht</surname> <given-names>MH</given-names>
</name>
<name>
<surname>Scholtz</surname> <given-names>JE</given-names>
</name>
<name>
<surname>Kraft</surname> <given-names>J</given-names>
</name>
<name>
<surname>Bauer</surname> <given-names>RW</given-names>
</name>
<name>
<surname>Kaup</surname> <given-names>M</given-names>
</name>
<name>
<surname>Dewes</surname> <given-names>P</given-names>
</name>
<etal/>
</person-group>. <article-title>Assessment of an Advanced Monoenergetic Reconstruction Technique in Dual-Energy Computed Tomography of Head and Neck Cancer</article-title>. <source>Eur Radiol</source> (<year>2015</year>) <volume>25</volume>(<issue>8</issue>):<page-range>2493&#x2013;501</page-range>. doi:&#xa0;<pub-id pub-id-type="doi">10.1007/s00330-015-3627-1</pub-id>
</citation>
</ref>
</ref-list>
</back>
</article>