AUTHOR=Zhu Tiantong , Chen Jiahui , Zhou Zimo , Ma Xiaofen , Huang Ying TITLE=Differentiation of Thyroid Nodules (C-TIRADS 4) by Combining Contrast-Enhanced Ultrasound Diagnosis Model With Chinese Thyroid Imaging Reporting and Data System JOURNAL=Frontiers in Oncology VOLUME=Volume 12 - 2022 YEAR=2022 URL=https://www.frontiersin.org/journals/oncology/articles/10.3389/fonc.2022.840819 DOI=10.3389/fonc.2022.840819 ISSN=2234-943X ABSTRACT=To establish a contrast-enhanced ultrasound (CEUS) diagnostic schedule by CEUS analysis of thyroid nodules of C-TIRADS 4. To establish a CEUS-TIRADS diagnostic model to differentiate thyroid nodules (C-TIRADS 4) by combining CEUS with C-TIRADS. A total of 228 thyroid nodules (C-TIRADS 4) were estimated by CEUS. Multivariate factors logistic analysis was performed and a CEUS diagnostic schedule was established. If the nodule had a regular hyper-enhancement ring or got less than 2 score in CEUS analysis, CEUS-TIRADS was subtracted 1 category. If the nodule got 2 score in CEUS schedule, the CEUS-TIRADS category was remained as same as before. If the nodule got more than 2 score in CEUS schedule, CEUS-TIRADS was added 1 category. When it reflected an absent enhancement in CEUS, the nodule was judged as CEUS-TIRADS 3. All of the C-TIRADS 4 nodules were re-graded by CEUS-TIRADS. Compare the diagnosis performance of C-TIRADS, CEUS and CEUS-TIRADS by sensitivity, specificity and accuracy. Among the 228 C-TIRADS 4 nodules, 69 were determined as C-TIRADS 4a, 114 were C-TIRADS 4b and 45 were C-TIRADS 4c. The sensitivity, specificity and accuracy of C-TIRADS were 93.1%, 55.3% and 74.6% respectively. The area under the curve was 0.753. Later arrival time, hypo-enhancement, heterogeneous enhancement, centripetal enhancement and rapid wash out were risk factors of malignancy in multivariate analysis. The sensitivity, specificity and accuracy of CEUS were 78.7%, 87.5% and 83.3% respectively. The area under the curve was 0.803. By CEUS-TIRADS diagnostic model combining CEUS with C-TIRADS, a total of 127 cases were determined as malignancy (111 were malignant and 16 were benign) and 101 were diagnosed as benign ones (5 were malignant and 96 were benign). The sensitivity, specificity and accuracy of CEUS-TIRADS were 95.7%, 85.7% and 92.1% respectively. The area under the curve was 0.916. The diagnostic performance of CEUS-TIRADS was significantly better than CEUS and C-TIRADS. The diagnostic schedule of CEUS could get a better diagnostic performance than US in differentiation of thyroid nodules. The CEUS-TIRADS combining CEUS analysis with C-TIRADS could make up the deficient sensibility of C-TIRADS, showing a better diagnostic performance than US and CEUS.