<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="research-article" dtd-version="2.3" xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Nucl. Eng.</journal-id>
<journal-title>Frontiers in Nuclear Engineering</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Nucl. Eng.</abbrev-journal-title>
<issn pub-type="epub">2813-3412</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">1654123</article-id>
<article-id pub-id-type="doi">10.3389/fnuen.2025.1654123</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Nuclear Engineering</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Applications of ultra-high resolution microcalorimeter gamma-ray spectrometry</article-title>
<alt-title alt-title-type="left-running-head">Schreiber et al.</alt-title>
<alt-title alt-title-type="right-running-head">
<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3389/fnuen.2025.1654123">10.3389/fnuen.2025.1654123</ext-link>
</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Schreiber</surname>
<given-names>Katherine A.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
<uri xlink:href="https://loop.frontiersin.org/people/3142695/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Koehler</surname>
<given-names>Katrina E.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Croce</surname>
<given-names>Mark P.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/3113201/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Stark</surname>
<given-names>Emily N.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/2906913/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>McNeel</surname>
<given-names>Daniel G.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Carpenter</surname>
<given-names>Matthew H.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/3037550/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Mercer</surname>
<given-names>David J.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/3145794/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Abel</surname>
<given-names>E. Paige</given-names>
</name>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Archambault</surname>
<given-names>Brian</given-names>
</name>
<xref ref-type="aff" rid="aff4">
<sup>4</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Arrigo</surname>
<given-names>Leah</given-names>
</name>
<xref ref-type="aff" rid="aff4">
<sup>4</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Batie</surname>
<given-names>Grey</given-names>
</name>
<xref ref-type="aff" rid="aff4">
<sup>4</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/3118391/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Becker</surname>
<given-names>Daniel T.</given-names>
</name>
<xref ref-type="aff" rid="aff5">
<sup>5</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Bennett</surname>
<given-names>Douglas A.</given-names>
</name>
<xref ref-type="aff" rid="aff6">
<sup>6</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Bucher</surname>
<given-names>Brian M.</given-names>
</name>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Dede</surname>
<given-names>Stefania</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/3170404/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Fowler</surname>
<given-names>Joseph</given-names>
</name>
<xref ref-type="aff" rid="aff6">
<sup>6</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Gard</surname>
<given-names>Johnathon D.</given-names>
</name>
<xref ref-type="aff" rid="aff5">
<sup>5</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Glasgow</surname>
<given-names>David</given-names>
</name>
<xref ref-type="aff" rid="aff7">
<sup>7</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/2799534/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Goetz</surname>
<given-names>K. C.</given-names>
</name>
<xref ref-type="aff" rid="aff7">
<sup>7</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Gray</surname>
<given-names>Craig</given-names>
</name>
<xref ref-type="aff" rid="aff7">
<sup>7</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Harabagiu</surname>
<given-names>Catalin</given-names>
</name>
<xref ref-type="aff" rid="aff4">
<sup>4</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Hu</surname>
<given-names>Jianwei</given-names>
</name>
<xref ref-type="aff" rid="aff7">
<sup>7</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Keller</surname>
<given-names>Mark W.</given-names>
</name>
<xref ref-type="aff" rid="aff6">
<sup>6</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/3118284/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Ben Mates</surname>
<given-names>J. A.</given-names>
</name>
<xref ref-type="aff" rid="aff6">
<sup>6</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Mathew</surname>
<given-names>Christine</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff8">
<sup>8</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>O&#x2019;Neil</surname>
<given-names>Galen C.</given-names>
</name>
<xref ref-type="aff" rid="aff6">
<sup>6</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Ortiz</surname>
<given-names>Nathan J.</given-names>
</name>
<xref ref-type="aff" rid="aff6">
<sup>6</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Pagani</surname>
<given-names>Luca</given-names>
</name>
<xref ref-type="aff" rid="aff4">
<sup>4</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Pierson</surname>
<given-names>Bruce D.</given-names>
</name>
<xref ref-type="aff" rid="aff4">
<sup>4</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Schmidt</surname>
<given-names>Daniel R.</given-names>
</name>
<xref ref-type="aff" rid="aff6">
<sup>6</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Schoenemann</surname>
<given-names>Rico U.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Seabury</surname>
<given-names>Edward</given-names>
</name>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Swetz</surname>
<given-names>Daniel S.</given-names>
</name>
<xref ref-type="aff" rid="aff6">
<sup>6</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Ullom</surname>
<given-names>Joel N.</given-names>
</name>
<xref ref-type="aff" rid="aff5">
<sup>5</sup>
</xref>
<xref ref-type="aff" rid="aff6">
<sup>6</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Weidenbenner</surname>
<given-names>Sophie L.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Williams</surname>
<given-names>Ammon N.</given-names>
</name>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
</contrib-group>
<aff id="aff1">
<sup>1</sup>
<institution>Los Alamos National Laboratory</institution>, <addr-line>Los Alamos</addr-line>, <addr-line>NM</addr-line>, <country>United States</country>
</aff>
<aff id="aff2">
<sup>2</sup>
<institution>Houghton University</institution>, <addr-line>Houghton</addr-line>, <addr-line>NY</addr-line>, <country>United States</country>
</aff>
<aff id="aff3">
<sup>3</sup>
<institution>Idaho National Laboratory</institution>, <addr-line>Idaho Falls</addr-line>, <addr-line>ID</addr-line>, <country>United States</country>
</aff>
<aff id="aff4">
<sup>4</sup>
<institution>Pacific Northwest National Laboratory</institution>, <addr-line>Richland</addr-line>, <addr-line>WA</addr-line>, <country>United States</country>
</aff>
<aff id="aff5">
<sup>5</sup>
<institution>University of Colorado Boulder</institution>, <addr-line>Boulder</addr-line>, <addr-line>CO</addr-line>, <country>United States</country>
</aff>
<aff id="aff6">
<sup>6</sup>
<institution>National Institute of Standards and Technology</institution>, <addr-line>Boulder</addr-line>, <addr-line>CO</addr-line>, <country>United States</country>
</aff>
<aff id="aff7">
<sup>7</sup>
<institution>Oak Ridge National Laboratory</institution>, <addr-line>Oak Ridge</addr-line>, <addr-line>TN</addr-line>, <country>United States</country>
</aff>
<aff id="aff8">
<sup>8</sup>
<institution>Texas A&#x26;M University</institution>, <addr-line>College Station</addr-line>, <addr-line>TX</addr-line>, <country>United States</country>
</aff>
<author-notes>
<fn fn-type="edited-by">
<p>
<bold>Edited by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1617571/overview">Amy Hixon</ext-link>, University of Notre Dame, United States</p>
</fn>
<fn fn-type="edited-by">
<p>
<bold>Reviewed by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1533773/overview">Ren&#xe9; Bes</ext-link>, University of Helsinki, Finland</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/3116991/overview">Orlando Quaranta</ext-link>, Argonne National Laboratory (DOE), United States</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/3117241/overview">Takahito Osawa</ext-link>, Japan Atomic Energy Agency, Japan</p>
</fn>
<corresp id="c001">&#x2a;Correspondence: Katherine A. Schreiber, <email>kschreiber@lanl.gov</email>
</corresp>
</author-notes>
<pub-date pub-type="epub">
<day>11</day>
<month>09</month>
<year>2025</year>
</pub-date>
<pub-date pub-type="collection">
<year>2025</year>
</pub-date>
<volume>4</volume>
<elocation-id>1654123</elocation-id>
<history>
<date date-type="received">
<day>26</day>
<month>06</month>
<year>2025</year>
</date>
<date date-type="accepted">
<day>22</day>
<month>08</month>
<year>2025</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2025 Schreiber, Koehler, Croce, Stark, McNeel, Carpenter, Mercer, Abel, Archambault, Arrigo, Batie, Becker, Bennett, Bucher, Dede, Fowler, Gard, Glasgow, Goetz, Gray, Harabagiu, Hu, Keller, Ben Mates, Mathew, O&#x2019;Neil, Ortiz, Pagani, Pierson, Schmidt, Schoenemann, Seabury, Swetz, Ullom, Weidenbenner and Williams.</copyright-statement>
<copyright-year>2025</copyright-year>
<copyright-holder>Schreiber, Koehler, Croce, Stark, McNeel, Carpenter, Mercer, Abel, Archambault, Arrigo, Batie, Becker, Bennett, Bucher, Dede, Fowler, Gard, Glasgow, Goetz, Gray, Harabagiu, Hu, Keller, Ben Mates, Mathew, O&#x2019;Neil, Ortiz, Pagani, Pierson, Schmidt, Schoenemann, Seabury, Swetz, Ullom, Weidenbenner and Williams</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<p>Ultra-high energy resolution microcalorimeter gamma-ray spectroscopy&#x2014;with energy resolution 5 to 10 times better than observed in spectra obtained by commercial-off-the-shelf high purity germanium detectors&#x2014;is an enabling technology for ultra-precise isotope identification and quantification. Microcalorimeter gamma spectroscopy complements measurements requiring high-accuracy mass spectrometry, a costly, destructive analysis technique, and may offer benefits over mass spectrometry in the future. Microcalorimeter detectors are fabricated from superconducting materials and operate at ultra-low temperatures (&#x3c;0.1&#xa0;K), properties which permit measurement of spectra with peak full width half maximum (FWHM) of less than 100&#xa0;eV at 100&#xa0;keV. The microcalorimeter collaboration between Los Alamos National Laboratory, National Institute of Standards and Technology, and University of Colorado, Boulder has deployed three microcalorimeter gamma-ray spectrometers to nuclear facilities and analytical laboratories so far. These are the Spectrometer Optimized for Facility Integrated Applications (SOFIA), a portable system that can be moved to any facility, and two instruments called the High Efficiency and Resolution Microcalorimeter Spectrometers (HERMES) intended for permanent installation at Idaho National Laboratory and Pacific Northwest National Laboratory. Each spectrometer was customized to satisfy requirements for their specific applications. This work describes samples examined by microcalorimeter gamma-ray spectrometers, including recently irradiated materials, nuclear material from various stages of the fuel cycle, and medical isotope products. It also highlights useful signatures from actinide and fission product gamma-rays that are otherwise infeasible to observe or use for analysis without costly chemical separations and mass spectrometric assay. Microcalorimeter technology provides additional spectral signatures to existing techniques to better constrain the origin and intended use of nuclear and radioactive materials.</p>
</abstract>
<kwd-group>
<kwd>gamma-ray spectrometry</kwd>
<kwd>nuclear fuel cycle</kwd>
<kwd>microcalorimeter spectrometer</kwd>
<kwd>nuclear forensics and safeguards</kwd>
<kwd>isotope identification</kwd>
</kwd-group>
<counts>
<page-count count="16"/>
</counts>
<custom-meta-wrap>
<custom-meta>
<meta-name>section-at-acceptance</meta-name>
<meta-value>Nuclear Materials</meta-value>
</custom-meta>
</custom-meta-wrap>
</article-meta>
</front>
<body>
<sec id="s1">
<title>1 Introduction</title>
<p>Advances in energy resolution in gamma-ray spectrometer technology over time have resulted in increasingly accurate, detailed, and precise nondestructive analysis of nuclear and radioactive material. Sodium iodide (NaI) spectrometers are known for portability and ease of use, but for many applications requiring high accuracy, high purity germanium (HPGe) spectrometers are required. HPGe detectors provide resolution as low as 550&#xa0;eV full width half maximum (FWHM) spectral peaks near 100&#xa0;keV (<xref ref-type="bibr" rid="B28">Mirion Technologies., 2023</xref>). Gamma spectroscopy is indeed a useful technique for nondestructive assay (<xref ref-type="bibr" rid="B26">Mayer et al., 2013</xref>; <xref ref-type="bibr" rid="B23">Keegan et al., 2016</xref>). Even so, the accuracy and precision of nuclide analysis by gamma spectrometry is still limited, and destructive analysis is typically necessary to attain the precision required of material characterization (<xref ref-type="bibr" rid="B26">Mayer et al., 2013</xref>; <xref ref-type="bibr" rid="B18">IAEA, 2015</xref>; <xref ref-type="bibr" rid="B20">IAEA, 2022</xref>). Mass spectrometers, for example, are workhorses of nuclear analytical laboratories. Chemical separation is necessary to prepare the samples for some vital techniques by mass spectrometry, such as multicollector inductively coupled plasma mass spectrometry (ICP-MS). This can add hours or days to the amount of time required to complete quantification of nuclides within a sample.</p>
<p>To more rapidly answer questions about the origin of the sample under analysis with the requisite accuracy, more precise nondestructive techniques are desirable to complement or better inform destructive measurements. Ultra-high energy resolution gamma-ray spectrometry, enabled by microcalorimeters, provides an avenue for such measurements. Microcalorimeter gamma-ray spectrometry, or simply gamma-ray microcal or &#x3bc;cal, uses highly sensitive detector arrays to attain peak FWHM as low as 53&#xa0;eV for peaks near 100&#xa0;keV&#x2014;nearly an order of magnitude better energy resolution than available via state-of-the-art non-destructive gamma-ray analysis techniques including traditional HPGe gamma spectrometry, Compton suppression, and gamma-gamma coincident spectroscopy (<xref ref-type="bibr" rid="B40">Ullom and Bennett, 2015</xref>). Such resolution enables identification of nuclides which are obscured as unresolvable gamma-ray peak interferences or by the Compton continuum produced by high-intensity sources present in the sample. It also facilitates lower uncertainties in counting gamma-rays of a given energy than in an HPGe spectrum of comparable counting statistics. Well-resolved peaks may be counted by merely summing the counts within a region of interest (ROI), but for overlapping peaks, the lower FWHM corresponds to lower uncertainty in performing Gaussian fits (<xref ref-type="bibr" rid="B14">Hoover et al., 2009</xref>; <xref ref-type="bibr" rid="B16">Hoover et al., 2013</xref>; <xref ref-type="bibr" rid="B17">Hoover et al., 2014</xref>). Lower uncertainty in calculating peak areas can translate to lower uncertainties in isotopic calculations. In fact, the uncertainty in such calculations is often limited by uncertainties in literature nuclear data, and not the microcal peak areas (<xref ref-type="bibr" rid="B44">Yoho et al., 2020a</xref>; <xref ref-type="bibr" rid="B2">Becker et al., 2023</xref>). The improved resolution also offers better precision from reduced variation in fitting or background continuum subtraction. Attaining satisfactory uncertainty and repeatability in nuclide activities as rapidly as possible is necessary to expedite facility operations and nuclear material investigations. This work provides an overview of microcal gamma-ray spectra obtained from a diverse array of samples. It is intended as a review of applications for which microcal may have an analytical benefit by demonstrating spectral features which are more well-resolved than in lower resolution gamma-ray detectors. These spectra invite opportunities for detailed studies and analysis of the most valuable spectral signatures. By enabling higher accuracy and precision, <italic>nondestructive</italic> analysis of nuclear material, gamma-ray microcal may prove to be a useful tool for many material characterization applications.</p>
</sec>
<sec id="s2">
<title>2 Instrumentation</title>
<sec id="s2-1">
<title>2.1 Gamma-ray microcalorimeters</title>
<p>Microcalorimeters attain ultra-high energy resolution by operating in an extremely low temperature, low noise environment. Transition edge sensors (TESs) are among the most technologically mature microcalorimeters and have enabled ultra-high energy resolution gamma spectroscopy (<xref ref-type="bibr" rid="B21">Irwin et al., 1996</xref>; <xref ref-type="bibr" rid="B3">Bennett et al., 2012</xref>; <xref ref-type="bibr" rid="B40">Ullom and Bennett, 2015</xref>). The TES microcalorimeter is designed to detect small temperature changes caused by absorption of a single gamma-ray photon in an absorber coupled to the TES. A schematic is shown in <xref ref-type="fig" rid="F1">Figure 1a</xref>. The temperature increase changes the resistance of the TES, allowing the absorbed gamma ray to be measured as a change in current, producing an electrical pulse. The pulses can then be measured and binned into high resolution spectra.</p>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption>
<p>
<bold>(a)</bold> Schematic thermal circuit for a TES and separate absorber connected to a thermal bath. Heat from absorption of the incident gamma ray flows to the TES, which serves as a sensitive thermometer, before eventually flowing to the bath. <bold>(b)</bold> Schematic cross section (not to scale) showing the Si wafer and silicon nitride membrane supporting the TES and Sn absorber mounted on epoxy posts.</p>
</caption>
<graphic xlink:href="fnuen-04-1654123-g001.tif">
<alt-text content-type="machine-generated">Diagram with two panels labeled a and b. Panel a shows a gamma ray hitting an absorber connected by springs to a thermal bath, with a thermometer beside the TES. Panel b illustrates a layered structure with a top Sn layer supported by epoxy above a silicon nitride layer. A TES is positioned on the layers, under which silicon blocks are placed.</alt-text>
</graphic>
</fig>
<p>A TES is a microfabricated device made of superconducting materials, with a superconducting critical temperature between 100&#xa0;mK and 150&#xa0;mK. This temperature can be tuned by adjusting the composition of Mo/Cu or Mo/Au bilayers used to form the TES. In the gamma microcals described here, the TES is placed on a silicon nitride membrane, as shown in <xref ref-type="fig" rid="F1">Figure 1b</xref>., allowing the thermal conductance to the bath to be adjusted, thereby tuning the time constant for recovery after absorption of a photon. When in operation, the TES is voltage-biased so its resistance lies within the narrow superconducting transition region. The current change from an absorbed photon is then measured by a superconducting quantum interference device (SQUID) (<xref ref-type="bibr" rid="B25">Mates et al., 2017</xref>; <xref ref-type="bibr" rid="B13">Gard et al., 2018</xref>) that acts as a highly sensitive current amplifier, enabling low-noise readout of the pulse due to the incident photon. Because of the sensitivity of the superconducting transition to magnetic fields, cryogenic magnetic shielding must be placed around the TESs and SQUIDs.</p>
<p>Because a TES pulse is limited by thermal time constants, which are relatively slow compared to electrical time constants, the practical count rate for a TES microcalorimeter gamma-ray spectrometer is comparatively low. For a single TES pixel, exceeding 20 counts per second per pixel tends to degrade the ultra-high energy resolution. A typical measurement may have count rates from 5&#x2013;10 counts per second per pixel, giving overall detector count rates of a few thousand counts per second for an array of several hundred pixels. Although current TES designs produce pulses tens of milliseconds long, upgrades to pixel design are expected to increase pulse speed by a factor of five or more.</p>
<p>In order to maintain high resolution and have good detection efficiency, a TES absorber must have a small heat capacity, yet have reasonable stopping power for the gamma rays of interest. High energy resolution requires minimizing both temperature and heat capacity (<xref ref-type="bibr" rid="B40">Ullom and Bennett, 2015</xref>). Currently, typical gamma-ray absorbers are made of tin, which has low heat capacity at operating temperature and fair stopping power for gamma rays. A single gamma-ray TES absorber is 1.3&#xa0;mm by 1.3&#xa0;mm in area, and 0.5&#xa0;mm thick. Such an absorber has fair (&#x3e;10%) efficiency from approximately 20&#xa0;keV&#x2013;300&#xa0;keV, with maximum efficiency around 100&#xa0;keV (54%). The Sn absorber is located above the TES and is attached to the membrane by thermally conductive posts.</p>
<p>Because of the small area of a single TES and the slow temporal rate of thermal conduction, arrays of hundreds of TESs have been developed to increase overall efficiency (<xref ref-type="bibr" rid="B15">Hoover et al., 2011</xref>; <xref ref-type="bibr" rid="B43">Winkler et al., 2015</xref>; <xref ref-type="bibr" rid="B25">Mates et al., 2017</xref>). The readout of such a large array can be accomplished by microwave multiplexing. This technique avoids the necessity for hundreds of cables connecting to the TES arrays by instead sending hundreds of microwave tones to the array on a single line. Each TES microcalorimeter is coupled to an individual microwave resonator on a common microwave feedline, in such a way that changing current through a TES changes the frequency of the corresponding resonator. These changing resonance frequencies can be read out simultaneously, allowing signals from hundreds TES detectors to be multiplexed onto a single pair of coaxial cables (<xref ref-type="bibr" rid="B25">Mates et al., 2017</xref>).</p>
<p>Pulses are recorded on an individual pixel basis each time a trigger threshold is exceeded, and these records are subjected to several pulse processing techniques before being used to generate a spectrum for each pixel (<xref ref-type="bibr" rid="B11">Fowler et al., 2016</xref>; <xref ref-type="bibr" rid="B1">Becker et al., 2019</xref>; <xref ref-type="bibr" rid="B45">Yoho et al., 2020b</xref>). First, pulses whose shape do not meet the requisite criteria are cut (e.g., electronic noise spikes and piled-up pulses). The pulse height is then extracted by applying an optimal filter to each pulse. After this, a drift correction algorithm is applied to the filtered pulse heights for each pixel. Then the spectra from each individual pixel are co-added using peak matching techniques. The final spectrum is energy calibrated using known reference peaks. Because all full pulse records are saved and processed into event-mode data, binning into energy is done during analysis after processing. Typically, spectra are binned into 32,768 channels, with 0.01 keV/channel. This is the case for all microcal spectra in this paper. These analysis techniques for filtering, drift correcting, and co-adding are under research and development for optimal performance.</p>
</sec>
<sec id="s2-2">
<title>2.2 Spectrometer Optimized for Facility Integrated Applications (SOFIA)</title>
<p>SOFIA is the first deployed microcalorimeter gamma spectrometer (<xref ref-type="bibr" rid="B7">Croce et al., 2022</xref>). SOFIA consists of an array of 256 TES pixels housed within a compact cryostat designed for easy transportation (<xref ref-type="fig" rid="F2">Figure 2</xref>). The cryostat housing the TES array is an adiabatic demagnetization refrigerator (ADR) (<xref ref-type="bibr" rid="B31">Pobell, 2007</xref>). It, like each of the TES-based gamma spectrometers described in this paper, is a liquid-cryogen-free system. They are cooled to approximately 4&#xa0;K by helium pulse tube refrigeration. This involves a compressor connected to the cryostat by pressurized helium lines several meters long. The ability to cool to the TES operating temperature, which is below 100&#xa0;mK, is provided by the adiabatic magnetization and demagnetization of a paramagnetic salt (<xref ref-type="bibr" rid="B31">Pobell, 2007</xref>). The TES array remains at the operating temperature for 1&#x2013;2 days before the array stage warms up towards 4&#xa0;K. The system must then be regenerated by running the magnetization and demagnetization cycle again, a process which takes approximately 2&#xa0;hours. The regeneration process interrupts measurements being taken, which is a disadvantage of ADRs.</p>
<fig id="F2" position="float">
<label>FIGURE 2</label>
<caption>
<p>
<bold>(a)</bold> SOFIA with associated electronics rack. <bold>(b)</bold> 256-pixel microcalorimeter detector array. Eight chips of TES pixels are seen in the center of the array box. <bold>(c)</bold> SOFIA at the ORNL IFEL hot cells measuring irradiated nuclear fuel through a collimated port in the cell.</p>
</caption>
<graphic xlink:href="fnuen-04-1654123-g002.tif">
<alt-text content-type="machine-generated">a. Laboratory setup with electronic equipment, including a tall, rectangular apparatus connected to various measurement devices on a table and rack.b. Close-up of a the TES array with multiple components, encased in a yellow frame, held by a person.c. Industrial setting with a similar tall, rectangular apparatus inside a containment unit, surrounded by machinery and safety barriers.</alt-text>
</graphic>
</fig>
<p>ADRs can be constructed with a relatively small form factor. In the case of SOFIA, the cryostat, pulse tube compressor, and electronics rack can be transported in the back of a pickup truck. The compressor requires 220&#xa0;V of single-phase power, commonly attainable in many scientific and industrial facilities. Additionally, while many compressors require chilled water for cooling, SOFIA&#x2019;s compressor is air-cooled, further simplifying facility requirements. SOFIA&#x2019;s portability has enabled measurement campaigns at multiple locations, including the High Flux Isotope Reactor (HFIR) and Irradiated Fuel Examination Laboratory (IFEL) at Oak Ridge National Laboratory.</p>
</sec>
<sec id="s2-3">
<title>2.3 High Efficiency and Resolution Microcalorimeter Spectrometer, 400 pixels (HERMES-400)</title>
<p>The High Efficiency and Resolution Microcalorimeter Spectrometer (HERMES)-style instrument marks several differences from SOFIA, giving it greater detection efficiency and longer uninterrupted measurement time (<xref ref-type="bibr" rid="B35">Schreiber et al., 2023</xref>). The HERMES-400 spectrometer has approximately 400 TES pixels. The microcalorimeter array reflects an updated form factor from the array within the SOFIA instrument. There are four modules, called microsnouts, each with 96 pixels on the end and readout chips mounted on the sides (<xref ref-type="fig" rid="F3">Figure 3a</xref>). This modular design allows multiple microsnouts to be tiled together to form an array with a large detector active area. The four microsnouts are facing downward on a spring-loaded mount (<xref ref-type="fig" rid="F3">Figure 3b</xref>). This aids in reducing vibrational coupling to the TES pixels, which is detrimental to performance.</p>
<fig id="F3" position="float">
<label>FIGURE 3</label>
<caption>
<p>
<bold>(a)</bold> Microsnout array with a 20&#xa0;mm square array of 96 TES pixels on the top, readout chips along the sides, and electrical connections near the bottom. <bold>(b)</bold> Microsnout mount, with two copper wrapped microsnouts seen at the bottom of the mount. <bold>(c)</bold> HERMES-400 dilution refrigerator at INL MFC ARL. Photo is shown in <xref ref-type="bibr" rid="B35">Schreiber et al., 2023</xref>.</p>
</caption>
<graphic xlink:href="fnuen-04-1654123-g003.tif">
<alt-text content-type="machine-generated">a. Close-up of a microchip with a stacked design, featuring gold connectors and intricate circuitry. b. Microsnout mount with a cylindrical structure, featuring copper and metal components, and various cables. c. Laboratory setting with a large cylindrical dilution refrigerator labeled &#x22;Blue Fors,&#x22; computer monitors, and control equipment.</alt-text>
</graphic>
</fig>
<p>The cryostat used for HERMES-400 (<xref ref-type="fig" rid="F3">Figure 3c</xref>) is a dilution refrigerator from BlueFors (<xref ref-type="bibr" rid="B31">Pobell 2007</xref>). As with the ADR, the system cools to &#x3c; 4K via a helium pulse-tube cryocooler. A mixture of He-3 and He-4 is then condensed within the system and circulated until it cools below 100&#xa0;mK. The advantage of the dilution refrigerator over the ADR is that it may continuously remain at operating temperature as long as the liquid helium mixture is circulating. Measurements do not need to be paused in order to regenerate the cooling process, as in the case of magnetizing and demagnetizing an ADR paramagnetic salt. The dilution refrigerator has a much larger spatial and facility requirement footprint, however. It is not easily portable, requiring a large frame approximately 2&#xa0;m tall, and separate gas handling unit with pumps for the He-3/He-4. Chilled water for cooling the pulse tube compressor and 480&#xa0;V three-phase power are required. Liquid nitrogen for trapping air and moisture impurities, which would freeze and block the liquid He-3 and He-4 circulation, is also needed. Therefore, unlike the portable SOFIA, HERMES instruments are intended for permanent installation in an analytical facility. HERMES-400 is installed at the Idaho National Laboratory Material and Fuel Complex Analytical Research Laboratory (MFC ARL).</p>
<p>HERMES-400 will play a role in analysis of nuclear fuels and reactor materials researched at INL. In particular, many advanced fuels like tristructural isotropic (TRISO) fuel (<xref ref-type="bibr" rid="B9">Demkowicz et al., 2019</xref>) and, in the near future, molten salts, come through the lab for pre- and post-irradiation analysis. The ARL also analyzes a wide variety of fuel and other nuclear material routinely, for example, mixed oxide (MOX) fuels, different uranium metal alloy fuels, and high-assay low-enriched uranium (HALEU). Many of these applications will be discussed in <xref ref-type="sec" rid="s3">Section 3</xref>.</p>
</sec>
<sec id="s2-4">
<title>2.4 High Efficiency and Resolution Microcalorimeter Spectrometer, 700 pixels (HERMES-700)</title>
<p>The HERMES-700 instrument leveraged much of the design experience obtained from development of the HERMES-400 instrument and included additional improvements in design to increase efficiency and reduce vibration induced noise (<xref ref-type="bibr" rid="B36">Schreiber et al. 2024</xref>). HERMES-700 (<xref ref-type="fig" rid="F4">Figure 4</xref>) is intended to have seven microsnouts for a total of approximately 700 pixels. It is also installed for long-term use in an analytical facility, the Radiochemical Processing Laboratory at Pacific Northwest National Laboratory. Like HERMES-400, the cryogenic infrastructure is a dilution refrigerator from BlueFors. To reduce issues with vibration observed in HERMES-400, a 200&#xa0;kg aluminum mass was installed on top of the frame for vibrational damping. Additionally, rather than a spring-loaded mount with downward facing microsnouts, the microsnouts face sideways in HERMES-700. The mount is clamped around rods which are wrapped in Kevlar cord. The Kevlar provides damping while the mount reduces the degrees of freedom of motion compared to the spring mount, providing a more mechanically and vibrationally stable system. Further, the side-facing geometry of the microsnouts enables a wider range of measurement configurations compared to the downward facing microsnouts. Dilute solutions can be placed directly against the cryostat face, while very active samples can be moved away to an appropriate distance.</p>
<fig id="F4" position="float">
<label>FIGURE 4</label>
<caption>
<p>
<bold>(a)</bold> HERMES-700&#xa0;at PNNL. <bold>(b)</bold> Photo of 4 of the 7 microsnouts installed in the HERMES-700 system <bold>(c)</bold> CAD rendering of assembled 7-snout system in a cutaway model of the cryostat.</p>
</caption>
<graphic xlink:href="fnuen-04-1654123-g004.tif">
<alt-text content-type="machine-generated">a. A cylindrical cooling apparatus labeled &#x22;BLUE FORS&#x22; is placed on a metallic support structure and surrounded by a laboratory setting. b. A close-up of a circuit board with TES microsnout array, labeled with numbers and featuring various electronic connections. c. A technical illustration of the internal structure of HERMES-700 internal structure, showing different components in various colors, including blue, orange, and pink.</alt-text>
</graphic>
</fig>
<p>At the time of writing, HERMES-700 employs four microsnouts for a total of 384 pixels. When complete, HERMES-700 will house seven total microsnouts arranged in a honeycomb format. This arrangement of microsnouts is an especially suitable measurement geometry for 4-inch diameter filter paper sources (<xref ref-type="bibr" rid="B5">Burnett and Miley, 2021</xref>). <xref ref-type="fig" rid="F4">Figure 4</xref> illustrates the CAD modeled structure of the microcalorimeter, internal assembly, and completed system.</p>
</sec>
</sec>
<sec id="s3">
<title>3 Applications of gamma-ray microcalorimetry</title>
<sec id="s3-1">
<title>3.1 Rapid identification of short-lived isotopes</title>
<p>The enhanced resolution of the microcalorimeter gamma-ray detector allows for identification of radionuclides with a precision that is difficult to achieve with lower-resolution detectors. This presents a powerful capability for investigations requiring rapid turnaround measurements. Microcalorimeter gamma-ray spectroscopy enables observation of key isotope signatures without requiring chemical separation and destructive analysis, particularly relevant for short-lived radionuclides that decay away before chemical separation and subsequent measurements can be performed.</p>
<p>Microcalorimeter gamma-ray measurements have illustrated capabilities for rapid radionuclide characterization in the case of recently irradiated materials. Microcalorimeter gamma-ray spectra have been obtained for irradiated materials at short time scales after irradiation performed at two reactor facilities: the Training, Research, Isotopes, General Atomics (TRIGA) reactor at Washington State University (WSU), (<xref ref-type="bibr" rid="B36">Schreiber et al. 2024</xref>) and the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory.</p>
<sec id="s3-1-1">
<title>3.1.1 Irradiation at Washington State University TRIGA reactor</title>
<p>At the WSU TRIGA reactor, a 2.2&#xa0;mg piece of 93.15% enriched uranium foil was irradiated for 2&#xa0;h at 500&#xa0;kW to produce 5.37 &#xd7; 10<sup>13</sup> fissions as determined through gamma analysis of peak fission products. Following irradiation, the sample was transported to PNNL for dissolution with 10&#xa0;mL of 3M HNO<sub>3</sub> and subsequently screened to determine the total sample activity. From this stock solution, an aliquot equivalent to 1 &#xd7; 10<sup>12</sup> fissions was prepared and dried down by evaporation onto a 2.2225&#xa0;cm diameter filter paper and laminated in Kapton tape. The filter paper was shipped to LANL and measured by SOFIA and HPGe detectors beginning 4&#xa0;days after the irradiation. <xref ref-type="fig" rid="F5">Figure 5</xref> presents the measured spectrum derived from microcalorimetry (black) and a low-energy germanium detector (brown).</p>
<fig id="F5" position="float">
<label>FIGURE 5</label>
<caption>
<p>Gamma-ray spectra (SOFIA microcal in black; HPGe in brown) of fission products collected after irradiation in WSU&#x2019;s TRIGA reactor.</p>
</caption>
<graphic xlink:href="fnuen-04-1654123-g005.tif">
<alt-text content-type="machine-generated">Graph comparing spectral data for irradiated highly enriched uranium (HEU) using &#x3BC;Cal and HPGe detectors. The x-axis shows energy in kiloelectronvolts (keV), and the y-axes show counts for &#x3BC;Cal and HPGe. Peaks are labeled with isotopes like Cerium (Ce) and Neodymium (Nd).</alt-text>
</graphic>
</fig>
<p>Key interferences of short-lived isotopes were resolved using the microcalorimeter that would otherwise be infeasible using germanium. <xref ref-type="fig" rid="F6">Figure 6</xref> illustrates the peak separation of Ba-140 and Ce-144, which have half-lives of 12.751(4) days and 284.91(5) days, and gamma rays at 132.687(1) keV and 133.515(2) keV, respectively. <xref ref-type="fig" rid="F7">Figure 7</xref> illustrates clear separation of the Sm-153 gamma-line, a crucial, refractory wing fission product with elevated sensitivity to the energy of the incident, fission inducing neutron. <xref ref-type="fig" rid="F6">Figures 6</xref>, <xref ref-type="fig" rid="F7">7</xref> are expanded views of the spectrum in <xref ref-type="fig" rid="F5">Figure 5</xref>. Quantification of fission product activity by gamma-ray microcal was not calculated from this measurement. Measurement of the sample alongside a well-characterized isotopic standard, or measurement in an efficiency calibrated geometry, would be necessary to extract these values. Efficiency calculations for quantification are an ongoing research focus for our collaboration, and further discussion is provided in <xref ref-type="sec" rid="s3-4">Section 3.4</xref>.</p>
<fig id="F6" position="float">
<label>FIGURE 6</label>
<caption>
<p>The 130&#xa0;keV&#x2013;135&#xa0;keV region of the spectrum in <xref ref-type="fig" rid="F5">Figure 5</xref> shows clear separation of the Ba-140/Ce-144 signature in the SOFIA microcal spectrum (black) compared to the planar HPGe spectrum (brown). The escape peak at 134.2&#xa0;keV is a microcal detector artifact from a Sn K&#x3b2;1 X-ray escaping from the Ba-140 162.66&#xa0;keV peak.</p>
</caption>
<graphic xlink:href="fnuen-04-1654123-g006.tif">
<alt-text content-type="machine-generated">Graph showing energy spectrum from 130 keV to 135 keV for irradiated HEU. &#x3BC;Cal counts per 10 eV are represented in black, and HPGe counts per 75 eV are in brown. Peaks are seen at 140&#x2093;Ba, 144&#x2093;Ce, and the Sn escape peak, with distinct sharp peaks and distributions on both scales. The y-axis shows counts, ranging from 10&#xB2; to 10&#x2075;.</alt-text>
</graphic>
</fig>
<fig id="F7" position="float">
<label>FIGURE 7</label>
<caption>
<p>The 100&#xa0;keV&#x2013;111&#xa0;keV region of the spectrum from <xref ref-type="fig" rid="F5">Figure 5</xref> shows clear separation in the SOFIA microcal spectrum of the Te-131&#xa0;m, Sm-153, and Pu X-rays from the Np-239 decay.</p>
</caption>
<graphic xlink:href="fnuen-04-1654123-g007.tif">
<alt-text content-type="machine-generated">Graph comparing fission products from irradiated highly enriched uranium highly enriched uranium (HEU) with two detectors: &#x3BC;Cal and HPGe, across an energy range of 100 to 110 keV. Peaks labeled 131mTe, 153Sm, Pu K&#x3B1;&#x2081; X-ray, 239Np, and 140La are visible, indicating different element emissions. The &#x3BC;Cal data is shown in black, with counts per 10 eV bin, while HPGe data is in brown, with counts per 75 eV bin. The graph highlights differences in sensitivity and resolution between the detectors.</alt-text>
</graphic>
</fig>
</sec>
<sec id="s3-1-2">
<title>3.1.2 Irradiation at Oak Ridge National Laboratory HFIR</title>
<p>At HFIR, SOFIA was placed in the Neutron Activation Analysis laboratory adjacent to the reactor, and samples were immediately measured after irradiation via transport by pneumatic tube. The spectra obtained represent the microcalorimeter measurements taken with the shortest amount of time after irradiation to date. Targets of natural uranium (NU), plutonium standards, and mixtures of the two were irradiated during the 511 cycle (February 2025) and immediately measured with the SOFIA microcalorimeter. The NU and Pu targets were irradiated for 90&#xa0;s when the reactor flux was approximately 4.3 &#xd7; 10<sup>13</sup>&#xa0;n/cm<sup>2</sup>&#xb7;s in the pneumatic transfer tube that passes just outside of the permanent beryllium reflector. Irradiation times for the uranium and plutonium mixtures were reduced to 60&#xa0;s to compensate for a 22% increase in the neutron flux that routinely occurs later in HFIR cycles. All samples were measured starting approximately 30&#x2013;45&#xa0;s post-irradiation. SOFIA observed between 4,000 and 8,000 counts per second on the full TES array at the beginning of the measurement, with the counts dying to less than 100 counts per second after about 45&#xa0;min.</p>
<p>The irradiations at HFIR enabled observation of temporally dynamic low energy gamma signatures from short-lived fission products. <xref ref-type="fig" rid="F8">Figure 8</xref> shows the half-life estimates for each energy bin between 0 and 100&#xa0;keV using an NU target. Each bin was evaluated, rather than each peak, because it is difficult to define regions of interest (ROIs) for individual unresolved peaks with short half-lives. The spectrum shown vertically in <xref ref-type="fig" rid="F8">Figure 8</xref> was created from the first 5&#xa0;minutes of the measurement. Dark, opaque dots represent high-confidence half-life estimates, ranging from 275&#xa0;s to 26&#xa0;min. Further analysis is underway for radionuclide identification, nuclear data studies, and U/Pu quantification.</p>
<fig id="F8" position="float">
<label>FIGURE 8</label>
<caption>
<p>Scatter plot of calculated half-lives of isotopes observed at given energies from uranium samples irradiated at HFIR, measured by the SOFIA microcal instrument.</p>
</caption>
<graphic xlink:href="fnuen-04-1654123-g008.tif">
<alt-text content-type="machine-generated">Scatter plot showing the relationship between energy in kiloelectron volts (keV) and half-life estimates in seconds. Data points vary in color representing relative uncertainty, with a color scale from dark purple to yellow. A grey line indicates the coadded spectrum.</alt-text>
</graphic>
</fig>
</sec>
<sec id="s3-1-3">
<title>3.1.3 Medical isotope: Actinium-225</title>
<p>Another interesting application for short-lived isotope characterization is within the field of medical isotopes. In particular, Ac-225, with half-life of 9.92 days, has become a promising targeted-alpha therapy treatment for cancer (<xref ref-type="bibr" rid="B38">Thiele and Wilson, 2018</xref>). Ac-225 is scarce, historically produced through extraction from a Th-229 &#x201c;cow&#x201d; in only a handful of laboratories. The Th-229 alpha decays to Ra-225 with a 7340-year half life, which then beta decays to Ac-225 (14.9-day half life). Accelerator-based methods are in use to vastly increase production (<xref ref-type="bibr" rid="B22">John, 2019</xref>). However, Ac-227 is an impurity which inevitably arises in accelerator production, with a half-life of 21.8 years. The presence of Ac-227 is problematic because it can accumulate in the liver, causing long-term damage to healthy cells. Characterizing the Ac-227 in Ac-225 for targeted alpha therapy is therefore important. An opportunity for gamma-ray microcal is to discern the extremely weak Ac-227 signatures. <xref ref-type="fig" rid="F9">Figure 9</xref> compares microcal gamma-ray spectra from an actinium sample obtained through accelerator-based methods and an actinium sample separated from a Th-229 cow. A gamma-ray peak from Th-227, a daughter of Ac-227, is highlighted in a spectrum from a sample obtained through accelerator production of actinium for targeted alpha therapy, which is distinctly not seen in the traditional Th-229 cow technique. None of these features are discernible in the HPGe spectrum. Using microcalorimeter decay energy spectroscopy, the signatures of Ac-227 were quantified (<xref ref-type="bibr" rid="B39">Tollefson et al., 2021</xref>), and the current results suggest gamma-ray microcal measurements are likewise a useful technique for medical actinium characterization.</p>
<fig id="F9" position="float">
<label>FIGURE 9</label>
<caption>
<p>Spectra of actinium samples produced by an accelerator and a Th-229 cow. The Th-227 peak at 50.13&#xa0;keV can be clearly seen in the accelerator-produced actinium sample (black) as a result of creating the Ac-227 contaminant. This signature cannot be resolved in the HPGe spectrum (brown). The signal-to-noise ratio (SNR) of the shaded region is used to predict how many counts in this peak are needed for various quantification precision levels. Black and blue traces are microcal spectra obtained by SOFIA.</p>
</caption>
<graphic xlink:href="fnuen-04-1654123-g009.tif">
<alt-text content-type="machine-generated">A graph showing energy spectra from 47 to 52 keV. The vertical axis on the left represents microcalorimeter counts per 10 eV bin, and on the right, HPGe counts per 500 eV bin. Three data series are plotted: HPGe Accelerator in brown, &#x3BC;Cal Accelerator in black, and &#x3BC;Cal &#xB2;&#xB2;&#x2079;Th Cow in blue. A dashed vertical line highlights &#xB2;&#xB2;&#x2077;Th, and a shaded region spans part of the spectrum. The logarithmic scale on the vertical axis shows counts ranging from 10&#xB2; to 10&#xB3;.</alt-text>
</graphic>
</fig>
<p>One of the main advantages of having such high energy resolution with microcal measurements is that small peaks can be seen due to the high signal to noise ratio. We can approximate the relative statistical uncertainty of the peak as follows:</p>
<p>
<inline-formula id="inf1">
<mml:math id="m1">
<mml:mrow>
<mml:mi>&#x3c3;</mml:mi>
<mml:mo>/</mml:mo>
<mml:mi>S</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:msqrt>
<mml:mrow>
<mml:msubsup>
<mml:mi>&#x3c3;</mml:mi>
<mml:mrow>
<mml:mi>B</mml:mi>
<mml:mtext>&#x2009;</mml:mtext>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msubsup>
<mml:mo>&#x2b;</mml:mo>
<mml:msubsup>
<mml:mi>&#x3c3;</mml:mi>
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mtext>&#x2009;</mml:mtext>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msubsup>
</mml:mrow>
</mml:msqrt>
</mml:mrow>
<mml:mrow>
<mml:mi>S</mml:mi>
</mml:mrow>
</mml:mfrac>
<mml:mo>,</mml:mo>
</mml:mrow>
</mml:math>
</inline-formula> where the uncertainties in the background (<inline-formula id="inf2">
<mml:math id="m2">
<mml:mrow>
<mml:msub>
<mml:mi>&#x3c3;</mml:mi>
<mml:mi>B</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>) and signal (<inline-formula id="inf3">
<mml:math id="m3">
<mml:mrow>
<mml:msub>
<mml:mi>&#x3c3;</mml:mi>
<mml:mi>S</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>) are added in quadrature and the signal, S, is the counts above background. With reasonably high backgrounds, we can approximate <inline-formula id="inf4">
<mml:math id="m4">
<mml:mrow>
<mml:msub>
<mml:mi>&#x3c3;</mml:mi>
<mml:mi>B</mml:mi>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:msqrt>
<mml:mrow>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mrow>
<mml:mi>b</mml:mi>
<mml:mi>i</mml:mi>
<mml:mi>n</mml:mi>
<mml:mi>s</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#xb7;</mml:mo>
<mml:msub>
<mml:mi>&#x3bc;</mml:mi>
<mml:mi>B</mml:mi>
</mml:msub>
</mml:mrow>
</mml:msqrt>
</mml:mrow>
</mml:math>
</inline-formula>, where the number of bins (<inline-formula id="inf5">
<mml:math id="m5">
<mml:mrow>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mrow>
<mml:mi>b</mml:mi>
<mml:mi>i</mml:mi>
<mml:mi>n</mml:mi>
<mml:mi>s</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>) is the number of spectral bins required to span 5 FWHM centered around the peak and <inline-formula id="inf6">
<mml:math id="m6">
<mml:mrow>
<mml:msub>
<mml:mi>&#x3bc;</mml:mi>
<mml:mi>B</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is the average number of counts in a background bin. The uncertainty in the signal (counts above background) is approximated as <inline-formula id="inf7">
<mml:math id="m7">
<mml:mrow>
<mml:msqrt>
<mml:mi>S</mml:mi>
</mml:msqrt>
</mml:mrow>
</mml:math>
</inline-formula>. The principal advantage for quantifying weak peaks here is that microcal improves signal to noise by reducing the background uncertainty since the peak is more localized in energy (i.e., <inline-formula id="inf8">
<mml:math id="m8">
<mml:mrow>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mrow>
<mml:mi>b</mml:mi>
<mml:mi>i</mml:mi>
<mml:mi>n</mml:mi>
<mml:mi>s</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is lower). To achieve 1% statistical uncertainty on the Th-227 50.13&#xa0;keV peak area, this would require 12,000 counts above background (in this case, determined from the microcal spectrum of the Th-229 cow between 49.9&#xa0;keV and 50.4 keV, &#x223c;3.8 FWHM). To achieve 10% statistical uncertainty, this would require 600 counts in this peak. Background levels change as a function of total source activity, so these and all following calculations are only approximations. The microcal spectra shown in <xref ref-type="fig" rid="F9">Figure 9</xref> were taken for 4,000&#xa0;s and represents a measurement with approximately 10% statistical precision. The HPGe spectrum is of the accelerator product, and was obtained beginning at the same time as the microcal spectrum of the accelerator product, running for a live time of 665&#xa0;s. The HPGe spectrum shown was obtained by a coaxial HPGe detector, unlike most of the other HPGe spectra shown in this paper. After the actinium samples were synthesized, there was only a short window of time to obtain spectra, and a higher energy resolution HPGe detector was not available. Future measurements involving a detailed comparison between HPGe and microcal would necessitate a planar HPGe detector. Due to the narrow FWHM of the Th-227 peak (131&#xa0;eV), however, it is not expected that even a planar detector would resolve this peak. Reproducing this measurement, using well-characterized isotopic standards along with the actinium samples for efficiency calibration, will be necessary for using these peak results for quantifying the amount of Ac-227 present.</p>
</sec>
</sec>
<sec id="s3-2">
<title>3.2 Uranium and plutonium isotopic composition</title>
<sec id="s3-2-1">
<title>3.2.1 Uranium enrichment</title>
<p>Yet another application of gamma-ray microcal is for highly precise enrichment measurements. As high-assay low-enriched uranium (HALEU) fuel becomes more central in the development of advanced nuclear reactors, precision in enrichment measurements becomes more crucial (<xref ref-type="bibr" rid="B19">IAEA, 2020</xref>). HALEU may have enrichments up to 20%, while 20% enrichment and above is considered highly enriched uranium (HEU). For HALEU enriched over 19%, therefore, uncertainty must be low enough to determine with confidence that the material does not in fact fall into the highly enriched category. Gamma-ray techniques are frequently used already for nondestructive enrichment calculations. Precision may be enhanced by gamma-ray microcal, because it resolves more peaks which can be used in the enrichment calculation. The region from 89&#xa0;keV to 94&#xa0;keV is particularly rich with closely spaced peaks (<xref ref-type="fig" rid="F10">Figure 10</xref>), which are well-resolved by microcal. These spectra are from uranium standards NBS031 (0.31% U-235) and NBL0005-20 (20% U-235). For NBS031, the microcal measurement was 130,000&#xa0;s, and the HPGe measurement 3,265&#xa0;s live time. For NBL0005-20, the microcal measurement was 120,000&#xa0;s and the HPGe was 1,075&#xa0;s live time. The high energy resolution also distinguishes the shape of x-ray peaks from that of gamma-ray peaks: x-rays have a Lorentzian line shape, while gamma-rays have a Gaussian profile. For gamma-ray microcal enrichment calculations, a fixed-response analysis method (<xref ref-type="bibr" rid="B34">Sampson et al., 1989</xref>; <xref ref-type="bibr" rid="B41">Vo, 2021</xref>) is under development (<xref ref-type="bibr" rid="B2">Becker et al., 2023</xref>). The technique computes the relative efficiency curve to extract a calculation of enrichment. For this, multiple peaks are needed for fitting across an extended energy range. The greater number of well-resolved uranium and thorium peaks will provide more points for the relative efficiency curve calculation. Further, reduced statistical uncertainty in the narrower peak areas of microcal spectra compared to HPGe are expected to contribute to reduced uncertainty in the isotopic percentage calculation. This is discussed in greater detail below for the case of Pu isotopics.</p>
<fig id="F10" position="float">
<label>FIGURE 10</label>
<caption>
<p>Uranium, thorium, and protactinium peaks displayed for two enrichments in SOFIA microcal spectra (black and blue) compared to HPGe spectra (dark brown and light brown). This energy region is rich with peaks that may be used for enhanced enrichment calculations.</p>
</caption>
<graphic xlink:href="fnuen-04-1654123-g010.tif">
<alt-text content-type="machine-generated">Graph comparing energy spectra for Uranium measurements using HPGe and &#x3BC;Cal detectors at different enrichment levels (0.31% and 20%). The x-axis represents energy in kiloelectronvolts, and the y-axis shows counts. Peaks are labeled for thorium, uranium, protactinium, and actinium isotopes. Four distinct lines correspond to different detector setups and enrichments.</alt-text>
</graphic>
</fig>
<p>The HPGe spectra shown here and throughout the paper are, in general, not necessarily taken at the same time or with the same measurement geometry as the microcal spectra, unless otherwise specified. All spectra are only intended to illustrate examples in which a microcal spectrum may prove particularly useful over an HPGe spectrum due to the higher number of peaks resolved.</p>
</sec>
<sec id="s3-2-2">
<title>3.2.2 U-238 direct gamma rays</title>
<p>For samples older than about 6&#xa0;months old, uranium isotopic composition calculation by gamma-ray spectrometry relies on daughter products of U-238, particularly Pa-234&#xa0;m. For samples where the uranium is freshly separated from daughter products, the sample is not yet in secular equilibrium, and gamma rays emitted directly by U-238 are needed. There are only two direct gamma rays from U-238&#xa0;at 49.55 keV and 113.5&#xa0;keV. These peaks are difficult to resolve with lower-resolution detectors due to their low branching fractions (0.064 photons per 100 decays and 0.0102 decays per 100 decays, respectively) and interference from nearby peaks. However, they are visible using gamma-ray microcal, as seen in <xref ref-type="fig" rid="F11">Figure 11</xref>, which shows the 113-keV region of the same microcal and HPGe spectra of NBS031 as in <xref ref-type="fig" rid="F10">Figure 10</xref>. Microcal is expected to enable more precise enrichment measurements for freshly separated uranium. In this spectrum, the number of gamma-rays in the 113.5&#xa0;keV peak at the 1% and 10% level with approximately 20,000 and 1,400 counts, respectively, over the light blue region in <xref ref-type="fig" rid="F11">Figure 11</xref>. In this 130,000-s spectrum measuring depleted uranium, this peak area was quantified with approximately 7% statistical uncertainty.</p>
<fig id="F11" position="float">
<label>FIGURE 11</label>
<caption>
<p>Depleted uranium spectrum for SOFIA and HPGe from uranium standard NBS031, showing the U-238 gamma ray distinguished at 113.5&#xa0;keV among other spectral features. The background below the peak (light shaded region, 5 FWHM) is approximated using the dark shaded region to predict how many counts in this peak are needed for various quantification precision levels. (In IUPAC notation: K&#x3b2;<sub>3</sub> &#x3d; K-M<sub>2</sub>, K&#x3b2;<sub>1</sub> &#x3d; K-M<sub>3,</sub> K&#x3b2;<sup>I</sup>
<sub>2</sub> &#x3d; K-N<sub>3,</sub> K&#x3b2;<sup>II</sup>
<sub>2</sub> &#x3d; K-N<sub>2,</sub> K&#x3b2;<sup>I</sup>
<sub>5</sub> &#x3d; K-M<sub>5,</sub> K&#x3b2;<sup>II</sup>
<sub>5</sub> &#x3d; K-M<sub>4</sub>).</p>
</caption>
<graphic xlink:href="fnuen-04-1654123-g011.tif">
<alt-text content-type="machine-generated">Graph showing gamma-ray spectra for uranium enrichment at 0.31% using microcalorimeter and HPGe detectors. The x-axis is energy in keV, with labeled peaks for U, Pa, Th, and U isotopes. The y-axes display counts per eV bin for both detectors, highlighting differences in spectral resolution.</alt-text>
</graphic>
</fig>
</sec>
<sec id="s3-2-3">
<title>3.2.3 Plutonium isotopics</title>
<p>The high resolution of gamma-ray microcal enables highly resolved plutonium spectra. This is valuable to calculations of plutonium isotopic ratios with increased precision. <xref ref-type="fig" rid="F12">Figure 12</xref> displays highly resolved plutonium peaks for several different burnups in the plutonium standard CBNM series compared to a HPGe spectrum. These peaks are used in the fixed response analysis method calculations for calculation of the percentage of each Pu isotope within the sample (<xref ref-type="bibr" rid="B34">Sampson et al., 1989</xref>; <xref ref-type="bibr" rid="B41">Vo 2021</xref>; <xref ref-type="bibr" rid="B2">Becker et al., 2023</xref>). High resolution of peaks enables lower statistical uncertainty in peak area calculations. Peaks may be well separated enough to allow a region of interest (ROI) calculation to count the number of photons measured within a peak, which results in a lower uncertainty than peak fitting. For peaks which still require fitting to a Gaussian or Lorentzian profile due to neighboring peak interferences, statistical uncertainty still tends to be reduced due to the narrower peak shape of a microcal peak compared to HPGe.</p>
<fig id="F12" position="float">
<label>FIGURE 12</label>
<caption>
<p>Spectra of plutonium standards from the CBNM series of varying burnups, measured by SOFIA (black, blue, and teal) and by HPGe (brown). The labeled peaks are those used for isotopic analysis.</p>
</caption>
<graphic xlink:href="fnuen-04-1654123-g012.tif">
<alt-text content-type="machine-generated">Plot showing energy spectra from 96 to 105 keV, comparing HPGe and &#x3BC;Cal detectors for isotopes \(^{239}\)Pu, \(^{241}\)Am, \(^{238}\)Pu, \(^{241}\)Pu, and \(^{240}\)Pu. The counts per energy bin are displayed, with a legend indicating data sources: CBNM84, CBNM61, and CBNM93.</alt-text>
</graphic>
</fig>
<p>Improvement in statistical uncertainty in calculation of the peak area ratios for isotopes of Pu showed as much as a factor of 5.3 improvement over the statistical uncertainty obtained from peak areas in HPGe (<xref ref-type="bibr" rid="B17">Hoover et al., 2014</xref>). The lower statistical uncertainty was most notable for closely spaced peaks such as those from Pu-238 and Pu-239, and less notable for peaks which are already prominent and well-isolated in HPGe spectra such as Pu-241 and Pu-239.</p>
<p>Again, like the HPGe spectra throughout this paper, the HPGe spectrum in <xref ref-type="fig" rid="F12">Figure 12</xref> is meant to be a representative example to demonstrate the greater richness of peaks observed in a microcal spectrum. Quantitative analysis of HPGe peak areas is not performed in this paper. The quantitative comparisons between HPGe and microcal discussed here are derived from the cited works (<xref ref-type="bibr" rid="B17">Hoover et al., 2014</xref>; <xref ref-type="bibr" rid="B44">Yoho et al., 2020a</xref>) and not the spectra shown.</p>
<p>Calculation of the isotopic percentages requires not only the peak areas, but also nuclear data, namely, half-lives and gamma-ray emission probabilities. For many gamma-ray peaks in U and Pu, it has been found that the limiting factor in uncertainty is the gamma-ray emission probability (<xref ref-type="bibr" rid="B44">Yoho et al., 2020a</xref>). There are therefore opportunities for gamma-ray microcal to <italic>improve</italic> the uncertainty nuclear data by measuring well-characterized isotopic standards and using the microcal peaks to calculate more precise values for the gamma-ray emission probabilities. Initial implementations of this analysis for Pu isotopic standards improved uncertainties for several gamma-ray emission probabilities by up to a factor of 3.5 times lower than the National Nuclear Data Center (NNDC) uncertainty values (<xref ref-type="bibr" rid="B44">Yoho et al., 2020a</xref>). The uncertainty budgets for the top seven most improved branching ratios from (<xref ref-type="bibr" rid="B44">Yoho et al., 2020a</xref>) are given in <xref ref-type="fig" rid="F13">Figure 13</xref>. This figure shows the areas of uncertainty with most room for improvement in microcal measurements. For each of the gamma rays investigated, the largest contributions to uncertainty were the fixed branching ratios of other gamma rays used in the calculation and Poisson statistics. This highlights that even these seven branching ratios can be measured more precisely with longer measurements and higher count rates, which should become more feasible as work progresses to make transition edge sensors faster and arrays of pixels larger. There is also ongoing work to improve atomic data, notably x-ray lineshapes and energies (<xref ref-type="bibr" rid="B42">Wessels et al., 2023</xref>). The field of neutron activation analysis is also identified as an area from which reduced uncertainty in gamma-ray energies would be highly beneficial. Microcal offers significant potential for improving nuclear and atomic data for other applications.</p>
<fig id="F13" position="float">
<label>FIGURE 13</label>
<caption>
<p>The uncertainty budget for seven branching ratios most improved by microcal measurements (<xref ref-type="bibr" rid="B44">Yoho et al., 2020a</xref>). The y-axis represents what percent of the reported uncertainty on the branching ratio from a given isotope comes from a particular origin (categories on the x-axis). This plot demonstrates the potential for significantly more improvement with longer run times and a reduction of the dependent branching ratio uncertainties.</p>
</caption>
<graphic xlink:href="fnuen-04-1654123-g013.tif">
<alt-text content-type="machine-generated">Bar chart showing the percentage contribution to uncertainty from different sources for branching ratio calculations. Fixed branching ratios contribute the most significantly, notably Am241 at 125.3 keV. Poisson statistics also show considerable contributions. Other factors like isotopics, half-lives, and efficiency model have minimal impact.</alt-text>
</graphic>
</fig>
<p>Another signature well-suited for microcalorimeter gamma-ray measurements is that of Np-237 (<xref ref-type="bibr" rid="B6">Croce et al., 2021</xref>). The Np-237 peak has the energy of 86.48&#xa0;keV and can be well-resolved from the neighboring peak originating from Pa-233, its daughter. This, along with the ability to observe well-resolved U-238 peaks, presents a potential for gamma-ray radiochronometry. The parent-to-daughter ratios of U-238/Pa-234&#xa0;m and Np-237/Pa-233 are useful radiochronometry ratios (<xref ref-type="bibr" rid="B26">Mayer et al., 2013</xref>). This avenue has not yet been explored with gamma-ray microcal, but future work exploring the precision and uncertainty limits of the technique is anticipated.</p>
<p>Finally, opportunities for observing other rarely-observed peaks abound in gamma-ray microcal spectra of Pu. These include observations of weak Pu-242 gamma-ray peaks (<xref ref-type="bibr" rid="B37">Teti et al., 2023</xref>; <xref ref-type="bibr" rid="B27">Mercer et al., 2022</xref>) and a previously unseen peak triplet in Am-241 (<xref ref-type="bibr" rid="B24">Koehler et al., 2021</xref>).</p>
</sec>
</sec>
<sec id="s3-3">
<title>3.3 Nuclear fuel signatures</title>
<p>Gamma-ray microcal has also been demonstrated for determining characteristics of nuclear fuels, including burnup, cooling time, and other key signatures that may help indicate the origin of the fuel and type of reactor in which it was irradiated.</p>
<sec id="s3-3-1">
<title>3.3.1 U/Pu ratio</title>
<p>A significant signature enabled by microcal is the ability to estimate the uranium to plutonium ratio in spent fuel from x-ray signatures. Uranium and plutonium fluorescence x-ray peak areas are correlated to the amount of uranium and plutonium in the sample. Taking the ratio of the areas of the x-ray peaks is a way to extract the U/Pu ratio within the sample (<xref ref-type="bibr" rid="B32">Rasmussen and Cohan., 1962</xref>; <xref ref-type="bibr" rid="B33">Rudy et al., 2006</xref>). The U/Pu ratio is an important indicator for burnup of the fuel (<xref ref-type="bibr" rid="B26">Mayer et al., 2013</xref>). The longer the fuel has been irradiated, the higher the burnup, and the higher the ratio of plutonium to uranium will be, as the uranium captures more and more neutrons and transmutes to plutonium.</p>
<p>In the Advanced Gas Reactor (AGR) experiments (<xref ref-type="bibr" rid="B30">Pham et al., 2021</xref>), tristructural isotropic (TRISO) fuel, a type of advanced reactor fuel (<xref ref-type="bibr" rid="B9">Demkowicz et al., 2019</xref>), was irradiated at the INL Advanced Test Reactor. Gamma-ray microcal spectra were obtained for dissolved TRISO and for solid TRISO fuel compacts. <xref ref-type="fig" rid="F14">Figure 14a</xref> shows a 60,000-s spectrum obtained by SOFIA of the U K&#x3b1;<sub>1</sub> (K-L<sub>3</sub>), Pu K&#x3b1;<sub>1</sub>, and Pu K&#x3b1;<sub>2</sub> (K-L<sub>2</sub>) x-rays in irradiated TRISO compact 2&#x2013;633. The item has a burnup of 7.46% fissions per initial metal atom (FIMA) and was measured after a cooling time of 134 months. Both Pu x-rays in particular are observable in the microcal spectrum due to the lower signal to noise ratio enabled by microcal. For comparison, a 3387-s live time HPGe spectrum of TRISO compact 5&#x2013;223 is shown. This item has even higher burnup (14.33% FIMA), and therefore a higher percentage of plutonium than the 2&#x2013;633 item, and was measured after a cooling time of 38 months. However, the HPGe Pu K&#x3b1;<sub>2</sub> peak in particular is obscured by the neighboring U K&#x3b1;<sub>1</sub>. In this microcal spectrum, the X-rays could be quantified at the 1% and 10% level with approximately 40,000 counts and 3,400 counts, respectively. In this spectrum, for example, we are able to quantify the Pu K&#x3b1;<sub>1</sub> peak with approximately 2% statistical uncertainty. The calculation of the x-ray peak ratios is therefore enabled.</p>
<fig id="F14" position="float">
<label>FIGURE 14</label>
<caption>
<p>
<bold>(a)</bold> SOFIA microcalorimeter spectrum for irradiated AGR 2 TRISO compact 2&#x2013;633 (7.46% FIMA) and HPGe spectrum for irradiated AGR 5/6/7 TRISO compact 5&#x2013;223 (14.33% FIMA). The U K&#x3b1;1, Pu K&#x3b1;1, and Pu K&#x3b1;2 peaks are indicated. The background below the peak (light shaded region, 5 FWHM) is approximated using the dark shaded region to predict how many counts in this peak are needed for various quantification precision levels. <bold>(b)</bold> The ratio of the Pu K&#x3b1;2 x-ray peak area to the U K&#x3b1;1 peak area, plotted as a function of burnup expressed in fissions per initial metal atom (% FIMA).</p>
</caption>
<graphic xlink:href="fnuen-04-1654123-g014.tif">
<alt-text content-type="machine-generated">Chart a depicts energy spectra with two labeled peaks at U K&#x3B1;1 and Pu K&#x3B1;2, K&#x3B1;1. Black and brown lines represent &#x3BC;Cal and HPGe counts, showing 7.46% and 14.33% FIMA, respectively. Chart b is a scatter plot with % FIMA on the x-axis and Puka2:Uka1 on the y-axis, displaying three data points with error bars.</alt-text>
</graphic>
</fig>
<p>The Pu K&#x3b1;<sub>2</sub>/U K&#x3b1;<sub>1</sub> is a particularly useful ratio, as the peaks are close in energy, and there is negligible variation in the efficiency curve between measurements, so the peaks may be meaningfully compared. A plot of the Pu K&#x3b1;<sub>2</sub>/U K&#x3b1;<sub>1</sub> peak ratios as a function of burnup in fissions per initial metal atom (FIMA) is provided in <xref ref-type="fig" rid="F14">Figure 14b</xref>. Because the intensity of the x-ray is related to the amount of material present, the peak area ratio of Pu K&#x3b1;<sub>2</sub>/U K&#x3b1;<sub>1</sub> should be related to the ratio of Pu/U in the fuel. There is an increasing trend, as may be expected, due to the increasing formation of Pu with increased burnup. More work will be needed, however, to explain the exact shape of the curve. Further studies on more materials across a greater range of reactor conditions will help to fill in points on the curve and extract a functional form. From a complete set of data across many burnups, it may be possible to predict burnup from the ratio of the x-ray peak areas, previously only feasible with destructive techniques. We do not find a trend for the Pu K&#x3b1;<sub>1</sub>/U K&#x3b1;<sub>1</sub> values. We believe that across the wider energy range, there is more variation in the efficiency, and therefore a simple Pu K&#x3b1;<sub>1</sub>/U K&#x3b1;<sub>1</sub> ratio is less meaningful without accounting for the efficiency.</p>
<p>The intensity of U and Pu x-rays can also be an indicator for the concentration of U and Pu in a source. U and Pu x-rays are prominent in microcal spectra of irradiated AGR compacts, for example, but are not seen in dilute solutions. In dilute solution, the U, Pu, and beta-emitting fission products are much less concentrated. Therefore, self-fluorescence of the U and Pu x-rays and x-ray fluorescence induced by the beta emissions are both much less probable. Such an x-ray signature obtained from a sample of unknown origin provides evidence as to the density and U/Pu concentration within the sample, helping to quickly discern the sample form.</p>
</sec>
<sec id="s3-3-2">
<title>3.3.2 Cooling time indicators</title>
<p>Highly resolved gamma-ray peaks from fission products also have great potential for indicators about the fuel origin. Eu-154 and Eu-155 are strong candidate isotopes for use in calculation of cooling time, or time since irradiation (<xref ref-type="bibr" rid="B8">Croce et al., 2023</xref>). Eu-154 has already been used in ratios with other isotopes to estimate cooling time and burnup (<xref ref-type="bibr" rid="B10">Favalli et al., 2016</xref>). Gamma-ray microcal enables potentially more accurate measures of cooling time through comparison of Eu-154 with Eu-155, because a nearby Eu-155 peak is also resolvable (<xref ref-type="bibr" rid="B35">Schreiber et al., 2023</xref>). For example, HERMES-400 obtained a 600,000-s spectrum from electrorefiner salt solution (<xref ref-type="bibr" rid="B12">Frederickson and Yoo., 2023</xref>), a solution containing fission products from spent fuel separated from uranium and transuranic products. Notable interferences of Eu-155 from Np-239 near 106&#xa0;keV were resolved, which may allow for a better estimate of the Eu-155 concentration in the sample (<xref ref-type="fig" rid="F15">Figure 15</xref>). The Eu-155 peak at 105.3&#xa0;keV could be quantified at the 1% and 10% level with approximately 18,000 counts and 1,200 counts, respectively. In this spectrum, we are able to quantify this peak with approximately 3.5% statistical uncertainty. This peak area may be compared to the peak area of Eu-154&#xa0;at 123.07&#xa0;keV for cooling time estimates. For comparison of visible peaks, a 14,400-s live time HPGe spectrum of the same item, measured 70 days earlier, is shown. In general, gamma-ray microcal could become a tool to monitor material through all steps of nuclear fuel cycle operations, including potential reprocessing operations such as electrorefinery. The rich quantity of gamma rays in spent fuel materials provides a variety of signatures that could be useful in material tracking.</p>
<fig id="F15" position="float">
<label>FIGURE 15</label>
<caption>
<p>Electrorefiner salt solution spectra obtained at INL by HERMES-400 demonstrating resolution of interferences by microcal, notably for Eu-155 and Np-239.</p>
</caption>
<graphic xlink:href="fnuen-04-1654123-g015.tif">
<alt-text content-type="machine-generated">Graph showing energy spectrum between 90 and 130 keV comparing two measurement methods: &#xB5;Cal and HPGe. The &#xB5;Cal spectrum (black line) shows sharper peaks at specific energies compared to the HPGe spectrum (brown line). Peaks are labeled for elements \(^{239}\text{Np}\), \(^{155}\text{Eu}\), and \(^{154}\text{Eu}\). The y-axis indicates counts per bin for each method, with &#xB5;Cal on the left and HPGe on the right.</alt-text>
</graphic>
</fig>
</sec>
</sec>
<sec id="s3-4">
<title>3.4 Ongoing work: efficiency calculations</title>
<p>Calculation of the measurement efficiency is an essential component for extracting activity or isotopic ratios from the spectra displayed. A fixed response analysis technique for computing relative efficiency can be used in some cases to extract isotopic ratios, as described in <xref ref-type="bibr" rid="B44">Yoho et al., 2020a</xref>. A technique to be used for general measurements would involve the co-measurement of an efficiency standard along with the sample of interest. This standard would have a well-characterized isotopic composition, so that the peak areas for this standard can be used for a relative efficiency calculation and applied towards the quantification of isotopes for the sample in question. This technique has not yet been explored for the spectra shown in this paper, but is an area of immediate future study.</p>
<p>Absolute efficiency calculations for quantification of nuclide activities are another component of research and development for our collaboration. The technique is challenging, but important even in conventional gamma-ray spectroscopy (<xref ref-type="bibr" rid="B4">Burdeinyi et al., 2020</xref>; <xref ref-type="bibr" rid="B29">Patra et al., 2024</xref>), typically involving detector modeling. The technique is even more challenging with gamma-ray microcal due to the pixelated TES nature of the detectors. Work to quantify absolute efficiency curves for the microcal detectors is ongoing. Using HERMES-700&#xa0;at PNNL, modeling and sample holders for reproducible sample placement are being implemented to address these considerations. A custom Bosch frame was added to the system and 3D printed sample holders designed to facilitate careful, repeatable placement of samples for analysis (<xref ref-type="fig" rid="F16">Figure 16</xref>). A precision GEANT4 model of the system was also established to support instrument performance assessments and measurement predictions.</p>
<fig id="F16" position="float">
<label>FIGURE 16</label>
<caption>
<p>
<bold>(a)</bold> Photo of the 3D printed Eckert &#x26; Ziegler type D sealed source sample holder. <bold>(b)</bold> GEANT4 CAD rendering of the sample counting geometry.</p>
</caption>
<graphic xlink:href="fnuen-04-1654123-g016.tif">
<alt-text content-type="machine-generated">Panel a shows a close-up of a metal apparatus with cylindrical components and screws. Panel b depicts a diagram with a circular arrangement of six patterned squares within turquoise borders, suggesting a layout design.</alt-text>
</graphic>
</fig>
<p>A portable germanium detector can also be positioned juxtaposed to the microcal spectrometer to provide a secondary measurement resource of samples and to evaluate the microcalorimeter spectral response relative to a well-known, calibrated system. Dead-time and detector efficiency variations due to pulse filtering and noise in the microcalorimeter complicate quantitative analysis, and comparing measured spectra <italic>in-situ</italic> to a well-known instrument is one method for addressing these uncertainties. We expect to further explore this method in future measurements.</p>
</sec>
</sec>
<sec sec-type="discussion" id="s4">
<title>4 Discussion</title>
<p>Advances in instrumentation and analysis are now enabling the application of passive, nondestructive microcalorimeter gamma-ray spectroscopy to a wide variety of sample types across the nuclear fuel cycle and radionuclide analysis applications. The ultra-high energy resolution and improved peak-to-background ratios can provide more information than conventional gamma spectroscopy with high-purity germanium detectors. In analytical laboratories, microcalorimeter gamma-ray spectrometry may complement destructive analyses either by pre-screening samples or providing additional information to inform other measurement techniques. For example, inter-element isotope ratios or those with isobaric interferences may be measured with different systematic uncertainties and potentially similar precision to mass spectrometry. This includes ratios of Np-237 and Am-241/243 to total Pu, or Pu-238 in the presence of large quantities of U-238.</p>
<p>Gamma-ray microcal enables higher-precision nondestructive isotopic analysis and the use of more spectral signatures to better characterize nuclear and radioactive material in addition to the opportunity to improve nuclear and atomic data. Continued advancement in array size, data acquisition techniques, and operational stability are underway to bring the benefits of this technology to industry. Implementation in analytical laboratories is expected to improve confidence in results and analysis capacity for wide-ranging applications.</p>
</sec>
</body>
<back>
<sec sec-type="data-availability" id="s5">
<title>Data availability statement</title>
<p>The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.</p>
</sec>
<sec sec-type="author-contributions" id="s6">
<title>Author contributions</title>
<p>KS: Writing &#x2013; original draft, Writing - review and editing, Conceptualization, Formal Analysis, Investigation, Methodology. KK: Writing &#x2013; original draft, Writing &#x2013; review and editing, Formal Analysis. MC: Writing &#x2013; original draft, Writing &#x2013; review and editing, Conceptualization. ES: Formal Analysis, Investigation, Writing &#x2013; original draft. DM: Writing &#x2013; review and editing. MC: Writing &#x2013; review and editing. DM: Writing &#x2013; review and editing, EA: Writing &#x2013; review and editing. BA: Writing &#x2013; review and editing. LA: Writing &#x2013; review and editing. GB: Writing &#x2013; review and editing. DB: Writing &#x2013; review and editing. DB: Writing &#x2013; review and editing. BB: Writing &#x2013; review and editing. SD: Writing &#x2013; review and editing. JF: Writing &#x2013; review and editing. JG: Writing &#x2013; review and editing. DG: Writing &#x2013; review and editing. KG: Writing &#x2013; review and editing. CG: Writing &#x2013; review and editing. CH: Writing &#x2013; review and editing. JH: Writing &#x2013; review and editing. MK: Writing &#x2013; review and editing. JB: Writing &#x2013; review and editing. CM: Writing &#x2013; review and editing. GO: Writing &#x2013; review and editing. NO: Writing &#x2013; review and editing. LP: Writing &#x2013; review and editing. BP: Writing &#x2013; original draft, Writing &#x2013; review and editing. DS: Writing &#x2013; review and editing. RS: Writing &#x2013; review and editing. ES: Writing &#x2013; review and editing. DS: Writing &#x2013; review and editing. JU: Writing &#x2013; review and editing. SW: Writing &#x2013; review and editing. AW: Writing &#x2013; review and editing.</p>
</sec>
<sec sec-type="funding-information" id="s7">
<title>Funding</title>
<p>The author(s) declare that financial support was received for the research and/or publication of this article. Research presented in this article was supported by the U.S. Department of Energy Office of Nuclear Energy Material Protection, Accountancy, and Control Technology (MPACT) Program, Office of Nuclear Energy Advanced Reactor Safeguards and Security (ARSS) Program, and the National Nuclear Security Administration Office of Defense Nuclear Nonproliferation Research and Development.</p>
</sec>
<ack>
<p>Support from INL MFC Analytical Laboratory staff, ORNL IFEL staff, ORNL HFIR staff, LANL TA-55 staff, and PNNL Radiological Processing Laboratory and Washington State University staff were greatly appreciated in coordinating sample preparation and measurement. Many years of TES development at NIST/CU Boulder have also gone into these detectors, and we thank many researchers acknowledged for their work.</p>
</ack>
<sec sec-type="COI-statement" id="s8">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec sec-type="ai-statement" id="s9">
<title>Generative AI statement</title>
<p>The author(s) declare that no Generative AI was used in the creation of this manuscript.</p>
<p>Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.</p>
</sec>
<sec sec-type="disclaimer" id="s10">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ref-list>
<title>References</title>
<ref id="B1">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Becker</surname>
<given-names>D. T.</given-names>
</name>
<name>
<surname>Alpert</surname>
<given-names>B. K.</given-names>
</name>
<name>
<surname>Bennett</surname>
<given-names>D. A.</given-names>
</name>
<name>
<surname>Croce</surname>
<given-names>M. P.</given-names>
</name>
<name>
<surname>Fowler</surname>
<given-names>J. W.</given-names>
</name>
<name>
<surname>Gard</surname>
<given-names>J. D.</given-names>
</name>
<etal/>
</person-group> (<year>2019</year>). <article-title>Advances in analysis of microcalorimeter gamma-ray spectra</article-title>. <source>IEEE Trans. Nucl. Sci.</source> <volume>66</volume>, <fpage>2355</fpage>&#x2013;<lpage>2363</lpage>. <pub-id pub-id-type="doi">10.1109/tns.2019.2953650</pub-id>
</citation>
</ref>
<ref id="B2">
<citation citation-type="confproc">
<person-group person-group-type="author">
<name>
<surname>Becker</surname>
<given-names>D. T.</given-names>
</name>
<name>
<surname>Bennett</surname>
<given-names>D. A.</given-names>
</name>
<name>
<surname>Carpenter</surname>
<given-names>M. H.</given-names>
</name>
<name>
<surname>Croce</surname>
<given-names>M. P.</given-names>
</name>
<name>
<surname>Keller</surname>
<given-names>M. W.</given-names>
</name>
<name>
<surname>Koehler</surname>
<given-names>K. E.</given-names>
</name>
<etal/>
</person-group> (<year>2023</year>). &#x201c;<article-title>SAPPY: a new software pipeline for analysis of gamma-ray spectra produced by microcalorimeter and high-purity germanium detectors</article-title>,&#x201d; in <conf-name>Proceedings of the 2023 INMM &#x26; ESARDA Joint Virtual Annual Meeting</conf-name>.</citation>
</ref>
<ref id="B3">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bennett</surname>
<given-names>D. A.</given-names>
</name>
<name>
<surname>Horansky</surname>
<given-names>R. D.</given-names>
</name>
<name>
<surname>Schmidt</surname>
<given-names>D. R.</given-names>
</name>
<name>
<surname>Hoover</surname>
<given-names>A. S.</given-names>
</name>
<name>
<surname>Winkler</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Alpert</surname>
<given-names>K.</given-names>
</name>
<etal/>
</person-group> (<year>2012</year>). <article-title>A high resolution gamma-ray spectrometer based on superconducting microcalorimeters</article-title>. <source>Rev. Sci. Instrum.</source> <volume>83</volume>, <fpage>093113</fpage>. <pub-id pub-id-type="doi">10.1063/1.4754630</pub-id>
<pub-id pub-id-type="pmid">23020368</pub-id>
</citation>
</ref>
<ref id="B4">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Burdeinyi</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Kutnii</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Vanzha</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Levenets</surname>
<given-names>V.</given-names>
</name>
<name>
<surname>Turkin</surname>
<given-names>A.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>A new nondestructive iterative method for forensics characterization of uranium-bearing materials by HRGS</article-title>. <source>Appl. Radiat. Isotopes</source> <volume>166</volume>, <fpage>109433</fpage>. <pub-id pub-id-type="doi">10.1016/j.apradiso.2020.109433</pub-id>
<pub-id pub-id-type="pmid">32977242</pub-id>
</citation>
</ref>
<ref id="B5">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Burnett</surname>
<given-names>J. L.</given-names>
</name>
<name>
<surname>Miley</surname>
<given-names>H. S.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Performance characterization of the Radionuclide Aerosol Sampler/Analyzer air sampler during a high-activity release event</article-title>. <source>Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip.</source> <volume>985</volume>, <fpage>164650</fpage>. <pub-id pub-id-type="doi">10.1016/j.nima.2020.164650</pub-id>
</citation>
</ref>
<ref id="B6">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Croce</surname>
<given-names>M. P.</given-names>
</name>
<name>
<surname>Becker</surname>
<given-names>D. T.</given-names>
</name>
<name>
<surname>Koehler</surname>
<given-names>K. E.</given-names>
</name>
<name>
<surname>Ullom</surname>
<given-names>J. N.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Improved nondestructive isotopic analysis with practical microcalorimeter gamma spectrometers</article-title>. <source>J. Nucl. Material Manag.</source> <volume>49</volume> (<issue>3</issue>), <fpage>108</fpage>&#x2013;<lpage>113</lpage>. <pub-id pub-id-type="doi">10.48550/arXiv.2104.03376</pub-id>
</citation>
</ref>
<ref id="B7">
<citation citation-type="confproc">
<person-group person-group-type="author">
<name>
<surname>Croce</surname>
<given-names>M. P.</given-names>
</name>
<name>
<surname>Becker</surname>
<given-names>D. T.</given-names>
</name>
<name>
<surname>Bennett</surname>
<given-names>D. A.</given-names>
</name>
<name>
<surname>Boyd</surname>
<given-names>S. T. P.</given-names>
</name>
<name>
<surname>Cantor</surname>
<given-names>R. H.</given-names>
</name>
<name>
<surname>Carpenter</surname>
<given-names>M. H.</given-names>
</name>
<etal/>
</person-group> (<year>2022</year>). &#x201c;<article-title>Nuclear facility experience with the SOFIA ultra-high-resolution microcalorimeter gamma spectrometer</article-title>,&#x201d; in <conf-name>Proceedings of the 2022 INMM Annual Meeting</conf-name>.</citation>
</ref>
<ref id="B8">
<citation citation-type="confproc">
<person-group person-group-type="author">
<name>
<surname>Croce</surname>
<given-names>M. P.</given-names>
</name>
<name>
<surname>Mercer</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Schreiber</surname>
<given-names>K. A.</given-names>
</name>
<name>
<surname>McNeel</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Carpenter</surname>
<given-names>M. H.</given-names>
</name>
<name>
<surname>Schoenemann</surname>
<given-names>R.</given-names>
</name>
<etal/>
</person-group> (<year>2023</year>). &#x201c;<article-title>Characterization of dissolved high-burnup nuclear fuel with microcalorimeter, high purity germanium, and cadmium zinc Telluride gamma spectroscopy</article-title>,&#x201d; in <conf-name>Proceedings of the 2023 INMM &#x26; ESARDA Joint Virtual Annual Meeting</conf-name>.</citation>
</ref>
<ref id="B9">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Demkowicz</surname>
<given-names>P. A.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Hunn</surname>
<given-names>J. D.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Coated Particle fuel: historical perspectives and current progress</article-title>. <source>J. Nucl. Mater.</source> <volume>515</volume>, <fpage>434</fpage>&#x2013;<lpage>450</lpage>. <pub-id pub-id-type="doi">10.1016/j.jnucmat.2018.09.044</pub-id>
</citation>
</ref>
<ref id="B10">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Favalli</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Vo</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Grogan</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Jansson</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Liljenfeldt</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Mozin</surname>
<given-names>V.</given-names>
</name>
<etal/>
</person-group> (<year>2016</year>). <article-title>Determining initial enrichment, burnup, and cooling time of pressurized-water-reactor spent fuel assemblies by analyzing passive gamma spectra measured at the Clab interim-fuel storage facility in Sweden</article-title>. <source>Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip.</source> <volume>820</volume>, <fpage>102</fpage>&#x2013;<lpage>111</lpage>. <pub-id pub-id-type="doi">10.1016/j.nima.2016.02.072</pub-id>
</citation>
</ref>
<ref id="B11">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Fowler</surname>
<given-names>J. W.</given-names>
</name>
<name>
<surname>Alpert</surname>
<given-names>B. K.</given-names>
</name>
<name>
<surname>Doriese</surname>
<given-names>W. B.</given-names>
</name>
<name>
<surname>Joe</surname>
<given-names>Y.-I.</given-names>
</name>
<name>
<surname>O&#x2019;Neil</surname>
<given-names>G. C.</given-names>
</name>
<name>
<surname>Ullom</surname>
<given-names>J. N.</given-names>
</name>
<etal/>
</person-group> (<year>2016</year>). <article-title>The practice of pulse processing</article-title>. <source>J. Low Temp. Phys.</source> <volume>184</volume> (<issue>1</issue>), <fpage>374</fpage>&#x2013;<lpage>381</lpage>. <pub-id pub-id-type="doi">10.1007/s10909-015-1380-0</pub-id>
<pub-id pub-id-type="pmid">38516044</pub-id>
</citation>
</ref>
<ref id="B12">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Frederickson</surname>
<given-names>G. L.</given-names>
</name>
<name>
<surname>Yoo</surname>
<given-names>T.-S.</given-names>
</name>
</person-group> (<year>2023</year>). <source>Engineering scale pyroprocessing activities in the United States</source>. <publisher-name>Nuclear Regulatory Commission Report</publisher-name>. <comment>Task Order 31310022F0031. Idaho National Laboratory</comment>.</citation>
</ref>
<ref id="B13">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gard</surname>
<given-names>J. D.</given-names>
</name>
<name>
<surname>Becker</surname>
<given-names>D. T.</given-names>
</name>
<name>
<surname>Bennett</surname>
<given-names>D. A.</given-names>
</name>
<name>
<surname>Fowler</surname>
<given-names>J. W.</given-names>
</name>
<name>
<surname>Hilton</surname>
<given-names>G. C.</given-names>
</name>
<name>
<surname>Mates</surname>
<given-names>J. A. B.</given-names>
</name>
<etal/>
</person-group> (<year>2018</year>). <article-title>A scalable readout for microwave SQUID multiplexing of transition-edge sensors</article-title>. <source>J. Low Temp. Phys.</source> <volume>193</volume> (<issue>3&#x2013;4</issue>), <fpage>485</fpage>&#x2013;<lpage>497</lpage>. <pub-id pub-id-type="doi">10.1007/s10909-018-2012-2</pub-id>
</citation>
</ref>
<ref id="B14">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hoover</surname>
<given-names>A. S.</given-names>
</name>
<name>
<surname>Bacrania</surname>
<given-names>M. K.</given-names>
</name>
<name>
<surname>Hoteling</surname>
<given-names>N. J.</given-names>
</name>
<name>
<surname>Karpius</surname>
<given-names>P. J.</given-names>
</name>
<name>
<surname>Rabin</surname>
<given-names>M. W.</given-names>
</name>
<name>
<surname>Rudy</surname>
<given-names>C. R.</given-names>
</name>
<etal/>
</person-group> (<year>2009</year>). <article-title>Microcalorimeter arrays for ultra-high energy resolution x-and gamma-ray detection</article-title>. <source>J. Radioanal. Nucl. Chem.</source> <volume>282</volume>, <fpage>227</fpage>&#x2013;<lpage>232</lpage>. <pub-id pub-id-type="doi">10.1007/s10967-009-0223-3</pub-id>
</citation>
</ref>
<ref id="B15">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hoover</surname>
<given-names>A. S.</given-names>
</name>
<name>
<surname>Hoteling</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Rabin</surname>
<given-names>M. W.</given-names>
</name>
<name>
<surname>Ullom</surname>
<given-names>J. N.</given-names>
</name>
<name>
<surname>Bennett</surname>
<given-names>D. A.</given-names>
</name>
<name>
<surname>Karpius</surname>
<given-names>P. J.</given-names>
</name>
<etal/>
</person-group> (<year>2011</year>). <article-title>Large microcalorimeter arrays for high-resolution X- and gamma-ray spectroscopy</article-title>. <source>Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip.</source> <volume>652</volume> (<issue>1</issue>), <fpage>302</fpage>&#x2013;<lpage>305</lpage>. <pub-id pub-id-type="doi">10.1016/j.nima.2010.09.154</pub-id>
</citation>
</ref>
<ref id="B16">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hoover</surname>
<given-names>A. S.</given-names>
</name>
<name>
<surname>Winkler</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Rabin</surname>
<given-names>M. W.</given-names>
</name>
<name>
<surname>Vo</surname>
<given-names>D. T.</given-names>
</name>
<name>
<surname>Ullom</surname>
<given-names>J. N.</given-names>
</name>
<name>
<surname>Bennett</surname>
<given-names>D. A.</given-names>
</name>
<etal/>
</person-group> (<year>2013</year>). <article-title>Determination of plutonium isotopic content by microcalorimeter gamma-ray spectroscopy</article-title>. <source>IEEE Trans. Nucl. Sci.</source> <volume>60</volume> (<issue>2</issue>), <fpage>681</fpage>&#x2013;<lpage>688</lpage>. <pub-id pub-id-type="doi">10.1109/TNS.2013.2249091</pub-id>
</citation>
</ref>
<ref id="B17">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hoover</surname>
<given-names>A. S.</given-names>
</name>
<name>
<surname>Winkler</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Rabin</surname>
<given-names>M. W.</given-names>
</name>
<name>
<surname>Bennett</surname>
<given-names>D. A.</given-names>
</name>
<name>
<surname>Doriese</surname>
<given-names>W. B.</given-names>
</name>
<name>
<surname>Fowler</surname>
<given-names>J. W.</given-names>
</name>
<etal/>
</person-group> (<year>2014</year>). <article-title>Uncertainty of plutonium isotopic measurements with microcalorimeter and high-purity germanium detectors</article-title>. <source>IEEE Trans. Nucl. Sci.</source> <volume>61</volume> (<issue>4</issue>), <fpage>2365</fpage>&#x2013;<lpage>2372</lpage>. <pub-id pub-id-type="doi">10.1109/TNS.2014.2332275</pub-id>
</citation>
</ref>
<ref id="B18">
<citation citation-type="journal">
<collab>IAEA (International Atomic Energy Agency)</collab> (<year>2015</year>). <article-title>IAEA nuclear security series No. 2-G (Rev. 1): nuclear forensics in support of investigations implementing guide</article-title>.</citation>
</ref>
<ref id="B19">
<citation citation-type="journal">
<collab>IAEA (International Atomic Energy Agency)</collab> (<year>2020</year>). <article-title>Advances in small modular reactor technology developments</article-title>
</citation>
</ref>
<ref id="B20">
<citation citation-type="journal">
<collab>IAEA (International Atomic Energy Agency)</collab> (<year>2022</year>). <article-title>STR-368 Rev. 1.1: international target values for measurement uncertainties in safeguarding nuclear materials</article-title>.</citation>
</ref>
<ref id="B21">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Irwin</surname>
<given-names>K. D.</given-names>
</name>
<name>
<surname>Hilton</surname>
<given-names>G. C.</given-names>
</name>
<name>
<surname>Wollman</surname>
<given-names>D. A.</given-names>
</name>
<name>
<surname>Martinis</surname>
<given-names>J. M.</given-names>
</name>
</person-group> (<year>1996</year>). <article-title>X-ray detection using a superconducting transition-edge sensor microcalorimeter with electrothermal feedback</article-title>. <source>Appl. Phys. Lett.</source> <volume>69</volume> (<issue>13</issue>), <fpage>1945</fpage>&#x2013;<lpage>1947</lpage>. <pub-id pub-id-type="doi">10.1063/1.117630</pub-id>
</citation>
</ref>
<ref id="B22">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>John</surname>
<given-names>K.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>US DOE tri-lab production effort to provide accelerator-produced 225ac for radiotherapy: 2019 update J</article-title>. <source>Nucl. Med.</source> <volume>60</volume>. <pub-id pub-id-type="doi">10.1016/j.jmir.2019.11.009</pub-id>
</citation>
</ref>
<ref id="B23">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Keegan</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Kristo</surname>
<given-names>M. J.</given-names>
</name>
<name>
<surname>Toole</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Kips</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Young</surname>
<given-names>E.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Nuclear forensics: scientific analysis supporting law enforcement and nuclear security investigations</article-title>. <source>Anal. Chem.</source> <volume>88</volume> (<issue>3</issue>), <fpage>1496</fpage>&#x2013;<lpage>1505</lpage>. <pub-id pub-id-type="doi">10.1021/acs.analchem.5b02915</pub-id>
<pub-id pub-id-type="pmid">26703823</pub-id>
</citation>
</ref>
<ref id="B24">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Koehler</surname>
<given-names>K. E.</given-names>
</name>
<name>
<surname>Yoho</surname>
<given-names>M. D.</given-names>
</name>
<name>
<surname>Carpenter</surname>
<given-names>M. H.</given-names>
</name>
<name>
<surname>Croce</surname>
<given-names>M. P.</given-names>
</name>
<name>
<surname>Mercer</surname>
<given-names>D. J.</given-names>
</name>
<name>
<surname>Smith</surname>
<given-names>C. M.</given-names>
</name>
<etal/>
</person-group> (<year>2021</year>). <article-title>New experimentally observable gamma-ray Emissions from 241Am nuclear decay arXiv:2103</article-title>.<fpage>15893</fpage>
</citation>
</ref>
<ref id="B25">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mates</surname>
<given-names>J. A. B.</given-names>
</name>
<name>
<surname>Becker</surname>
<given-names>D. T.</given-names>
</name>
<name>
<surname>Bennett</surname>
<given-names>D. A.</given-names>
</name>
<name>
<surname>Dober</surname>
<given-names>B. J.</given-names>
</name>
<name>
<surname>Gard</surname>
<given-names>J. D.</given-names>
</name>
<name>
<surname>Hays-Wehle</surname>
<given-names>J. P.</given-names>
</name>
<etal/>
</person-group> (<year>2017</year>). <article-title>Simultaneous readout of 128 X-ray and gamma-ray transition-edge microcalorimeters using microwave SQUID multiplexing</article-title>. <source>Appl. Phys. Lett.</source> <volume>111</volume> (<issue>6</issue>), <fpage>062601</fpage>. <pub-id pub-id-type="doi">10.1063/1.4986222</pub-id>
</citation>
</ref>
<ref id="B26">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mayer</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Wallenius</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Varga</surname>
<given-names>Z.</given-names>
</name>
</person-group> (<year>2013</year>). <article-title>Nuclear forensic science: correlating measurable material parameters to the history of nuclear material</article-title>. <source>Chem. Rev.</source> <volume>113</volume> (<issue>2</issue>), <fpage>884</fpage>&#x2013;<lpage>900</lpage>. <pub-id pub-id-type="doi">10.1021/cr300273f</pub-id>
<pub-id pub-id-type="pmid">23194287</pub-id>
</citation>
</ref>
<ref id="B27">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mercer</surname>
<given-names>D. J.</given-names>
</name>
<name>
<surname>Winkler</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Koehler</surname>
<given-names>K. E.</given-names>
</name>
<name>
<surname>Becker</surname>
<given-names>D. T.</given-names>
</name>
<name>
<surname>Bennett</surname>
<given-names>D. A.</given-names>
</name>
<name>
<surname>Carpenter</surname>
<given-names>M. H.</given-names>
</name>
<etal/>
</person-group> (<year>2022</year>). <article-title>Quantification of 242Pu with a microcalorimeter gamma spectrometer</article-title>. <source>arXiv:2202</source>, <fpage>02933</fpage>. <pub-id pub-id-type="doi">10.48550/arXiv.2202.02933</pub-id>
</citation>
</ref>
<ref id="B28">
<citation citation-type="web">
<collab>Mirion Technologies</collab> (<year>2023</year>). <article-title>U-LEGe: ultra-low energy germanium detector</article-title>. <comment>Available online at: <ext-link ext-link-type="uri" xlink:href="https://www.mirion.com/products/technologies/spectroscopy-scientific-analysis/gamma-spectroscopy/detectors/hpge-detectors-accessories/u-lege-ultra-low-energy-germanium-detectors">https://www.mirion.com/products/technologies/spectroscopy-scientific-analysis/gamma-spectroscopy/detectors/hpge-detectors-accessories/u-lege-ultra-low-energy-germanium-detectors</ext-link>.</comment>
</citation>
</ref>
<ref id="B29">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Patra</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Mani</surname>
<given-names>A. M.</given-names>
</name>
<name>
<surname>Kumar</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Tripathi</surname>
<given-names>R.</given-names>
</name>
</person-group> (<year>2024</year>). <article-title>Interrogating a mixed actinide basket using high-resolution &#x3b3;-ray spectrometry: a nuclear forensic perspective on possible smuggling scenarios</article-title>. <source>Anal. Chem.</source> <volume>96</volume> (<issue>7</issue>), <fpage>2857</fpage>&#x2013;<lpage>2865</lpage>. <pub-id pub-id-type="doi">10.1021/acs.analchem.3c03779</pub-id>
<pub-id pub-id-type="pmid">38326983</pub-id>
</citation>
</ref>
<ref id="B30">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pham</surname>
<given-names>B. T.</given-names>
</name>
<name>
<surname>Palmer</surname>
<given-names>J. J.</given-names>
</name>
<name>
<surname>Marshall</surname>
<given-names>D. W.</given-names>
</name>
<name>
<surname>Sterbentz</surname>
<given-names>J. W.</given-names>
</name>
<name>
<surname>Hawkes</surname>
<given-names>G. L.</given-names>
</name>
<name>
<surname>Scates</surname>
<given-names>D. M.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>AGR 5/6/7 irradiation test final as-run report</article-title>.</citation>
</ref>
<ref id="B31">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Pobell</surname>
<given-names>F.</given-names>
</name>
</person-group> (<year>2007</year>). <source>Matter and methods at low temperatures, 3rd Ed.</source> <publisher-name>Springer</publisher-name>.</citation>
</ref>
<ref id="B32">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rasmussen</surname>
<given-names>N. C.</given-names>
</name>
<name>
<surname>Cohan</surname>
<given-names>M. D.</given-names>
</name>
</person-group> (<year>1962</year>). <article-title>Analysis of radiations from spent fuel elements using a bent-Crystal Spectrograph</article-title>. <source>Trans. Am. Nucl. Soc.</source> <volume>5</volume> (<issue>1</issue>), <fpage>24</fpage>.</citation>
</ref>
<ref id="B33">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rudy</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Chesson</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Hoover</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Rabin</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Ullom</surname>
<given-names>J. N.</given-names>
</name>
</person-group> (<year>2006</year>). <article-title>Determination of Pu in spent fuel assemblies using self-fluorescent X-rays</article-title>. <source>Trans. Am. Nuc. Soc.</source> <volume>95</volume>, <fpage>61</fpage>.</citation>
</ref>
<ref id="B34">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Sampson</surname>
<given-names>T. E.</given-names>
</name>
<name>
<surname>Nelson</surname>
<given-names>G. W.</given-names>
</name>
<name>
<surname>Kelley</surname>
<given-names>T. A.</given-names>
</name>
</person-group> (<year>1989</year>). <source>FRAM:A versatile code for analyzing the isotopic composition of plutonium from gamma-ray pulse height spectra</source>. <publisher-name>Los Alamos National Laboratory Report LA-11720-MS</publisher-name>.</citation>
</ref>
<ref id="B35">
<citation citation-type="confproc">
<person-group person-group-type="author">
<name>
<surname>Schreiber</surname>
<given-names>K. A.</given-names>
</name>
<name>
<surname>Wessels</surname>
<given-names>A. L.</given-names>
</name>
<name>
<surname>McNeel</surname>
<given-names>D. G.</given-names>
</name>
<name>
<surname>Keller</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Croce</surname>
<given-names>M. P.</given-names>
</name>
<name>
<surname>Carpenter</surname>
<given-names>M. H.</given-names>
</name>
<etal/>
</person-group> (<year>2023</year>). &#x201c;<article-title>Ultra-high energy resolution microcalorimeter gamma ray spectrometer for high precision nuclear fuel cycle research</article-title>,&#x201d; in <conf-name>Proceedings of the 2023 INMM &#x26; ESARDA Joint Virtual Annual Meeting</conf-name> (<publisher-name>IEEE</publisher-name>).</citation>
</ref>
<ref id="B36">
<citation citation-type="confproc">
<person-group person-group-type="author">
<name>
<surname>Schreiber</surname>
<given-names>K. A.</given-names>
</name>
<name>
<surname>McNeel</surname>
<given-names>D. G.</given-names>
</name>
<name>
<surname>Keller</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Croce</surname>
<given-names>M. P.</given-names>
</name>
<name>
<surname>Carpenter</surname>
<given-names>M. H.</given-names>
</name>
<name>
<surname>Sch&#xf6;nemann</surname>
<given-names>R. U.</given-names>
</name>
<etal/>
</person-group> (<year>2024</year>). &#x201c;<article-title>Ultra-high energy resolution gamma spectroscopy of fission products from freshly irradiated material</article-title>,&#x201d; in <conf-name>Proceedings of the 2024 INMM Annual Meeting</conf-name>.</citation>
</ref>
<ref id="B37">
<citation citation-type="confproc">
<person-group person-group-type="author">
<name>
<surname>Teti</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Becker</surname>
<given-names>D. T.</given-names>
</name>
<name>
<surname>Bennett</surname>
<given-names>D. A.</given-names>
</name>
<name>
<surname>Carpenter</surname>
<given-names>M. H.</given-names>
</name>
<name>
<surname>Croce</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>De Castro</surname>
<given-names>K.</given-names>
</name>
<etal/>
</person-group> (<year>2023</year>). &#x201c;<article-title>Quantification of 242 Pu with a microcalorimeter gamma spectrometer</article-title>,&#x201d; in <conf-name>Proceedings of the 2023 INMM &#x26; ESARDA Joint Virtual Annual Meeting</conf-name>.</citation>
</ref>
<ref id="B38">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Thiele</surname>
<given-names>N. A.</given-names>
</name>
<name>
<surname>Wilson</surname>
<given-names>J. J.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Actinium-225 for targeted &#x3b1; therapy: coordination chemistry and current chelation approaches</article-title>. <source>Radiopharmaceuticals</source> <volume>33</volume>, <fpage>336</fpage>&#x2013;<lpage>348</lpage>. <pub-id pub-id-type="doi">10.1089/cbr.2018.2494</pub-id>
<pub-id pub-id-type="pmid">29889562</pub-id>
</citation>
</ref>
<ref id="B39">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tollefson</surname>
<given-names>A. D.</given-names>
</name>
<name>
<surname>Smith</surname>
<given-names>C. M.</given-names>
</name>
<name>
<surname>Carpenter</surname>
<given-names>M. H.</given-names>
</name>
<name>
<surname>Croce</surname>
<given-names>M. P.</given-names>
</name>
<name>
<surname>Fassbender</surname>
<given-names>M. E.</given-names>
</name>
<name>
<surname>Koehler</surname>
<given-names>K. E.</given-names>
</name>
<etal/>
</person-group> (<year>2021</year>). <source>Appl. Radiat. Isotopes</source> <volume>172</volume>, <fpage>109693</fpage>. <pub-id pub-id-type="doi">10.1016/j.apradiso.2021.109693</pub-id>
<pub-id pub-id-type="pmid">33774323</pub-id>
</citation>
</ref>
<ref id="B40">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ullom</surname>
<given-names>J. N.</given-names>
</name>
<name>
<surname>Bennett</surname>
<given-names>D. A.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>Review of superconducting transition-edge sensors for x-ray and gamma-ray spectroscopy</article-title>. <source>Supercond. Sci. Technol.</source> <volume>28</volume>, <fpage>084003</fpage>. <pub-id pub-id-type="doi">10.1088/0953-2048/28/8/084003</pub-id>
</citation>
</ref>
<ref id="B41">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Vo</surname>
<given-names>D.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Improvements of FRAM version 6.1 journal of Nuc</article-title>. <source>Mater. Manag.</source> <volume>XLIX</volume> (<issue>3 19</issue>).</citation>
</ref>
<ref id="B42">
<citation citation-type="confproc">
<person-group person-group-type="author">
<name>
<surname>Wessels</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Becker</surname>
<given-names>D. T.</given-names>
</name>
<name>
<surname>Bennett</surname>
<given-names>D. A.</given-names>
</name>
<name>
<surname>Carpenter</surname>
<given-names>M. H.</given-names>
</name>
<name>
<surname>Croce</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Fowler</surname>
<given-names>J. W.</given-names>
</name>
<etal/>
</person-group> (<year>2023</year>). &#x201c;<article-title>Using gamma-ray microcalorimeters to lower uncertainty in non-destructive analysis measurements through improvement of nuclear reference data</article-title>,&#x201d; in <conf-name>Proceedings of the 2023 INMM &#x26; ESARDA Joint Virtual Annual Meeting</conf-name>.</citation>
</ref>
<ref id="B43">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Winkler</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Hoover</surname>
<given-names>A. S.</given-names>
</name>
<name>
<surname>Rabin</surname>
<given-names>M. W.</given-names>
</name>
<name>
<surname>Bennett</surname>
<given-names>D. A.</given-names>
</name>
<name>
<surname>Doriese</surname>
<given-names>W. B.</given-names>
</name>
<name>
<surname>Fowler</surname>
<given-names>J. W.</given-names>
</name>
<etal/>
</person-group> (<year>2015</year>). <article-title>256-pixel microcalorimeter array for high-resolution &#x3b3;-ray spectroscopy of mixed-actinide materials</article-title>. <source>Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip.</source> <volume>770</volume>, <fpage>203</fpage>&#x2013;<lpage>210</lpage>. <pub-id pub-id-type="doi">10.1016/j.nima.2014.09.049</pub-id>
</citation>
</ref>
<ref id="B44">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yoho</surname>
<given-names>M. D.</given-names>
</name>
<name>
<surname>Koehler</surname>
<given-names>K. E.</given-names>
</name>
<name>
<surname>Becker</surname>
<given-names>D. T.</given-names>
</name>
<name>
<surname>Bennett</surname>
<given-names>D. A.</given-names>
</name>
<name>
<surname>Carpenter</surname>
<given-names>M. H.</given-names>
</name>
<name>
<surname>Croce</surname>
<given-names>M. P.</given-names>
</name>
<etal/>
</person-group> (<year>2020a</year>). <article-title>Improved plutonium and americium photon branching ratios from microcalorimeter gamma spectroscopy</article-title>. <source>Nucl. Inst. Methods Phys. Res. A</source> <volume>977</volume>, <fpage>164307</fpage>. <pub-id pub-id-type="doi">10.1016/j.nima.2020.164307</pub-id>
</citation>
</ref>
<ref id="B45">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yoho</surname>
<given-names>M. D.</given-names>
</name>
<name>
<surname>Koehler</surname>
<given-names>K. E.</given-names>
</name>
<name>
<surname>Garner</surname>
<given-names>S. E.</given-names>
</name>
<name>
<surname>Vo</surname>
<given-names>D. T.</given-names>
</name>
<name>
<surname>Croce</surname>
<given-names>M. P.</given-names>
</name>
</person-group> (<year>2020b</year>). <article-title>Automated co-adding and energy calibration of large array microcalorimeter data with zero sample knowledge</article-title>. <source>Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip.</source> <volume>969</volume>, <fpage>164056</fpage>. <pub-id pub-id-type="doi">10.1016/j.nima.2020.164056</pub-id>
</citation>
</ref>
</ref-list>
</back>
</article>