<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" article-type="research-article" dtd-version="2.3" xml:lang="EN">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Neurosci.</journal-id>
<journal-title>Frontiers in Neuroscience</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Neurosci.</abbrev-journal-title>
<issn pub-type="epub">1662-453X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fnins.2024.1530216</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Neuroscience</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Does the audiogram shape influence the intracochlear recording of Electrocochleography during and after cochlear implantation?</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes">
<name><surname>Haumann</surname> <given-names>Sabine</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="corresp" rid="c001"><sup>&#x002A;</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/2898852/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/data-curation/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/project-administration/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Timm</surname> <given-names>Max E.</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/data-curation/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>B&#x00FC;chner</surname> <given-names>Andreas</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/supervision/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Lenarz</surname> <given-names>Thomas</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/696375/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/supervision/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Salcher</surname> <given-names>Rolf B.</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/869851/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/supervision/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
</contrib-group>
<aff id="aff1"><sup>1</sup><institution>Department of Otorhinolaryngology, Hannover Medical School</institution>, <addr-line>Hanover</addr-line>, <country>Germany</country></aff>
<aff id="aff2"><sup>2</sup><institution>Cluster of Excellence "Hearing4all"</institution>, <addr-line>Hanover</addr-line>, <country>Germany</country></aff>
<author-notes>
<fn fn-type="edited-by" id="fn0001">
<p>Edited by: June Sic Kim, Seoul National University, Republic of Korea</p>
</fn>
<fn fn-type="edited-by" id="fn0002">
<p>Reviewed by: Stefania Goncalves, University of Alabama at Birmingham, United States</p>
<p>Miguel Angelo Hyppolito, University of S&#x00E3;o Paulo, Brazil</p>
</fn>
<corresp id="c001">&#x002A;Correspondence: Sabine Haumann, <email>haumann.sabine@mh-hannover.de</email></corresp>
</author-notes>
<pub-date pub-type="epub">
<day>16</day>
<month>01</month>
<year>2025</year>
</pub-date>
<pub-date pub-type="collection">
<year>2024</year>
</pub-date>
<volume>18</volume>
<elocation-id>1530216</elocation-id>
<history>
<date date-type="received">
<day>18</day>
<month>11</month>
<year>2024</year>
</date>
<date date-type="accepted">
<day>30</day>
<month>12</month>
<year>2024</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x00A9; 2025 Haumann, Timm, B&#x00FC;chner, Lenarz and Salcher.</copyright-statement>
<copyright-year>2025</copyright-year>
<copyright-holder>Haumann, Timm, B&#x00FC;chner, Lenarz and Salcher</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<p>During cochlear implant (CI) surgery, it is desirable to perform intraoperative measurements such as Electrocochleography (ECochG) to monitor the inner ear function and thereby to support the preservation of residual hearing. However, a significant challenge arises as the recording location of intracochlear ECochG via the CI electrode changes during electrode insertion. This study aimed to investigate the relationships between intracochlear ECochG recordings, the position of the recording contact within the cochlea relative to its anatomy, and the implications for frequency and residual hearing preservation. Intraoperative ECochG recordings were conducted using the CI electrode (MED-EL) during the insertion of hearing preservation electrodes and after the insertion process. Recordings were continuously conducted using the most apical electrode (contact 1) during insertion. After insertion, the recordings were performed on all different electrode contacts. The electrode location in the cochlea during insertion was estimated using mathematical models and preoperative clinical imaging, while the postoperative electrode position was determined using postoperative clinical imaging. The study involved 10 adult CI recipients. In those with good low-frequency hearing, an increase in signal amplitude was observed, with the highest amplitudes closest to the stimulation frequency generators, and no phase change was observed. Conversely, patients with flat hearing loss exhibited a second peak with an opposite phase in the medial area of the cochlea. This study is the first to suggest that the pattern of the preoperative audiogram may influence the ECochG outcomes measured intraoperatively. Specifically, the ECochG responses during insertion appeared to behave as expected with good low-frequency hearing, while with flat hearing loss there appear to be further effects. These findings indicate that this approach can provide valuable information for the interpretation of intracochlearly recorded ECochG signals.</p>
</abstract>
<kwd-group>
<kwd>cochlear implant</kwd>
<kwd>hearing preservation</kwd>
<kwd>CI electrode location</kwd>
<kwd>electrocochleography</kwd>
<kwd>cochlear monitoring</kwd>
</kwd-group>
<counts>
<fig-count count="8"/>
<table-count count="3"/>
<equation-count count="0"/>
<ref-count count="59"/>
<page-count count="13"/>
<word-count count="8888"/>
</counts>
<custom-meta-wrap>
<custom-meta>
<meta-name>section-at-acceptance</meta-name>
<meta-value>Neuroprosthetics</meta-value>
</custom-meta>
</custom-meta-wrap>
</article-meta>
</front>
<body>
<sec sec-type="intro" id="sec1">
<title>Introduction</title>
<p>For the past several years, patients with significant residual hearing have been recommended cochlear implantation (CI) surgery with hearing preservation techniques if satisfactory speech understanding cannot be achieved with a conventional hearing aid. This concept primarily aims to provide these patients with a combination of acoustic and electrical hearing (<xref ref-type="bibr" rid="ref29">James et al., 2005</xref>; <xref ref-type="bibr" rid="ref19">Gantz et al., 2005</xref>; <xref ref-type="bibr" rid="ref4">Baumgartner et al., 2007</xref>; <xref ref-type="bibr" rid="ref36">Lenarz et al., 2009</xref>; <xref ref-type="bibr" rid="ref25">Helbig et al., 2011</xref>; <xref ref-type="bibr" rid="ref56">Von Ilberg et al., 2011</xref>; <xref ref-type="bibr" rid="ref28">Incerti et al., 2013</xref>; <xref ref-type="bibr" rid="ref5">B&#x00FC;chner et al., 2017</xref>; <xref ref-type="bibr" rid="ref44">Roland et al., 2018</xref>; <xref ref-type="bibr" rid="ref18">Gantz et al., 2018</xref>). For this purpose, monitoring of the cochlear function during CI electrode insertion is desirable to support the preservation of residual hearing.</p>
<p>An electrophysiologic method that has been increasingly used for monitoring the functional status of the cochlea during electrode insertion is electrocochleography (ECochG); for reviews, see, for example <xref ref-type="bibr" rid="ref30">Kim (2020)</xref>, <xref ref-type="bibr" rid="ref3">Barnes et al. (2021)</xref>, <xref ref-type="bibr" rid="ref31">Kim (2024)</xref>. In this method, the acoustically evoked electrical activities in the inner ear can be recorded intraoperatively during the insertion of the electrode.</p>
<p>The recorded ECochG signal comprises several components generated by the hair cells, basilar membrane, and auditory nerve, which are described thoroughly in the literature, e.g., <xref ref-type="bibr" rid="ref13">Eggermont (1974)</xref>, <xref ref-type="bibr" rid="ref52">Snyder and Schreiner (1984)</xref>, <xref ref-type="bibr" rid="ref15">Forgues et al. (2014)</xref>, <xref ref-type="bibr" rid="ref6">Buechner et al. (2022)</xref>, <xref ref-type="bibr" rid="ref24">Haumann et al. (2024)</xref>. Most studies concentrate on cochlear microphonics (CMs) and auditory nerve neurophonics (ANNs). These components are difficult to separate and are often referred to as ongoing responses (ORs). These components best reflect the status of the hair cells and the auditory nerve in the low frequencies, which is the range where most CI candidates have significant residual hearing.</p>
<p>The acoustic stimulus for ECochG is usually delivered via an insert earphone placed in the outer ear canal. The response signal can be recorded using either extracochlear or intracochlear recording electrodes.</p>
<p>Many research groups have found some correlations between extracochlear recordings made at or near the promontory wall and the preservation of residual preservation (<xref ref-type="bibr" rid="ref42">Radeloff et al., 2012</xref>; <xref ref-type="bibr" rid="ref14">Fitzpatrick et al., 2014</xref>; <xref ref-type="bibr" rid="ref2">Adunka et al., 2016</xref>; <xref ref-type="bibr" rid="ref9">Dalbert et al., 2016</xref>; <xref ref-type="bibr" rid="ref10">Dalbert et al., 2018</xref>) or with postoperative speech perception (<xref ref-type="bibr" rid="ref1">Abbas et al., 2017</xref>; <xref ref-type="bibr" rid="ref57">Walia et al., 2022</xref>). However, there has been a mixed picture of the overall benefit relative to the effort required for extracochlear recording (<xref ref-type="bibr" rid="ref23">Haumann et al., 2024</xref>). As such, intracochlear measurements have become routine for cochlear monitoring. Here, the signal can be recorded via the CI electrode, and all CI manufacturers now offer routine implementations (<xref ref-type="bibr" rid="ref12">Dalbert et al., 2021</xref>; <xref ref-type="bibr" rid="ref6">Buechner et al., 2022</xref>; <xref ref-type="bibr" rid="ref38">O&#x2019;Leary et al., 2023</xref>; <xref ref-type="bibr" rid="ref45">Saoji et al., 2023</xref>; <xref ref-type="bibr" rid="ref51">Sijgers et al., 2023</xref>; <xref ref-type="bibr" rid="ref21">Greisiger et al., 2024</xref>; <xref ref-type="bibr" rid="ref24">Haumann et al., 2024</xref>; <xref ref-type="bibr" rid="ref40">Panario et al., 2024</xref>; <xref ref-type="bibr" rid="ref58">Walia et al., 2024</xref>).</p>
<p>Potentials recorded with intracochlear electrodes are larger and are presumably more sensitive because the signal is recorded much closer to the generator than with extracochlear measurements. The main drawback of this approach is that the recording site moves during insertion, so several factors besides trauma to the cochlea contribute to the temporal dynamics of the signal, such as the changing distance between the recording electrode and the generator of the response. In addition, temporary blockages of the basilar membrane can reduce the signal amplitude.</p>
<p>Currently, several research groups are investigating the dynamics of the recorded signal during CI electrode insertion and their relationship to the preservation of residual hearing. Ideally, the signal recorded with the most apical electrode should continuously increase during insertion as the generator&#x2019;s characteristic frequency range, which depends on the stimulation frequency used, is approached. Depending on the electrode length, the electrode can be inserted beyond this characteristic frequency range, which should result in an amplitude drop on the most apical contacts. To analyze this, Saoi et al. stimulated with different frequencies during insertion to investigate the amplitude behavior when characteristic frequency ranges of generators are crossed in any case (<xref ref-type="bibr" rid="ref46">Saoji et al., 2019</xref>; <xref ref-type="bibr" rid="ref45">Saoji et al., 2023</xref>). They observed the expected amplitude drop under these conditions.</p>
<p>Haumann et al. differentiated whether a drop in amplitude during insertion could be explained by a change in the electrode position or by trauma to the cochlea based on the postoperative imaging and modeling of the exact location of the characteristic frequency region. After insertion, ECochG was measured again via various CI contacts (<xref ref-type="bibr" rid="ref24">Haumann et al., 2024</xref>). Other research groups hypothesized that a drop in the first half of insertion is more likely due to transient events such as temporary contact of the array with the basilar membrane, and a drop in the second half of insertion is more consistent with trauma and subsequent residual hearing loss (<xref ref-type="bibr" rid="ref32">Koka et al., 2018</xref>; <xref ref-type="bibr" rid="ref50">Sijgers et al., 2021</xref>).</p>
<p>Other groups have examined the phase and latency of the signal along with the amplitude. The hypothesis is that a drop in amplitude accompanied by a phase shift is not critical since the signal&#x2019;s phase also changes when the electrode is advanced. Conversely, an amplitude drop without an accompanying phase change would suggest the presence of cochlear trauma. It was found that the latter correlated quite strongly with residual hearing loss (<xref ref-type="bibr" rid="ref6">Buechner et al., 2022</xref>). Other research groups have also suggested including phase, latency, and neuronal components in the interpretation of these signals (<xref ref-type="bibr" rid="ref32">Koka et al., 2018</xref>; <xref ref-type="bibr" rid="ref20">Giardina et al., 2019</xref>; <xref ref-type="bibr" rid="ref50">Sijgers et al., 2021</xref>). Greisiger et al. combined the recording of intracochlear ECochG with fluoroscopy and analyzed the behavior of the recorded signal together with the microscopy video and the postoperative CT scan (<xref ref-type="bibr" rid="ref21">Greisiger et al., 2024</xref>). The main aim was to identify critical steps during CI electrode insertion, and they postulated that the combination of fluoroscopy and ECochG provides helpful information in this regard.</p>
<p>Another research group measured ECochG on several contacts after electrode insertion and calculated the individual components from the signal. In a large patient group, they observed that CMs and SPs, in particular, explain a moderate part of the variance in later, residual hearing and CI-aided speech understanding (<xref ref-type="bibr" rid="ref40">Panario et al., 2024</xref>).</p>
<p>In summary, intracochlear ECochG appears to have utility for monitoring residual hearing preservation, but there are still some unanswered questions about the behavior of the measured signal and subsequent residual hearing preservation.</p>
<p>In this study, intracochlear ECochG was measured in ten adult patients during and after CI insertion, and, together with pre- and postoperative imaging, the relation to subsequent residual hearing preservation was examined. Particular attention was paid to the course of the preoperative hearing threshold, as a corresponding influence was indicated in an earlier study (<xref ref-type="bibr" rid="ref24">Haumann et al., 2024</xref>). In the present study, more measurement points could be recorded due to the continuous measurement during insertion and the recording at 12 electrodes after insertion. This allows for a more precise evaluation than in the prior study. In addition, the phase of the signal and the course of the CI electrode impedances were analyzed in the present study.</p>
</sec>
<sec sec-type="methods|materials" id="sec2">
<title>Methods and materials</title>
<p>In this work, a monocentric, prospective study is presented. The study was approved by the local ethics committee (approval number 10007_BO_S_2021) and is in accordance with the ethical standards of the Declaration of Helsinki. Ten patients undergoing CI surgery underwent intraoperative intracochlear (IC) ECochG during and after electrode insertion using a research tool provided by the implant manufacturer (MED-EL, Innsbruck, Austria). The recordings were performed continuously during electrode insertion using the most apical CI electrode contact for recording (C1) with a stimulation frequency of 500&#x202F;Hz. After intraoperative insertion, recordings were performed at all CI electrode contacts using a stimulation frequency of 500&#x202F;Hz. Relationships were investigated between intraoperative electrophysiologic recordings, the location of the electrode within the cochlea, and the pre- and postoperative pure tone audiogram (PTA) thresholds on audiograms.</p>
<sec id="sec3">
<title>Preoperative evaluation</title>
<p>The preoperative CI candidate evaluation at our clinic follows a standardized protocol (<xref ref-type="bibr" rid="ref22">Haumann et al., 2019</xref>). This protocol includes both subjective and objective audiometric evaluations, clinical imaging such as CT and fMRI scans, and other relevant examinations. Patients select an implant system based on their preferences. The appropriate electrode length was chosen by considering residual hearing and the length of the cochlea (<xref ref-type="bibr" rid="ref59">W&#x00FC;rfel et al., 2014</xref>; <xref ref-type="bibr" rid="ref55">Timm et al., 2018</xref>).</p>
<p>Pure tone audiometry (PTA) was performed with an AD2117 audiometer from Audio-DATA GmbH (Duvensee, Germany), calibrated to hearing level (HL). Air conduction testing was performed using HDA300 headphones from Sennheiser Electronic GmbH (Wedemark, Germany), and bone conduction testing was performed with a KLH96 bone transducer from Westra Elektroakustik GmbH (Meitingen, Germany).</p>
</sec>
<sec id="sec4">
<title>Intracochlear ECochG recordings using the CI electrode</title>
<sec id="sec5">
<title>Measurement setup</title>
<p>For IC recordings, different MED-EL (Innsbruck, Austria) FLEX electrode arrays were used with the clinical CI measurement setup for MED-EL implants (MAX-Box, coil, and laptop) and the manufacturer&#x2019;s research software (MAESTRO 9.0.3, MED-EL). The acoustic stimulation was delivered via a Dataman 531 Arbitrary Waveform Generator (Dataman, Maiden Newton, United Kingdom) triggered by the MAESTRO Software. Stimulation was delivered using insert earphones (ER-3C 50 Ohm, Etymotic, Fort Worth, Texas, USA) with a sterile foam plug placed in the outer ear canal.</p>
<p>A 500&#x202F;Hz Hamming windowed pure tone burst of 8&#x202F;ms duration was used for stimulation. The stimulation level was calibrated to hearing level (HL) and set intraoperatively to 110&#x202F;dB. The polarity of the stimulus was set to condensation.</p>
<p>The following parameters were chosen for the recordings: An 8.1&#x202F;ms recording window was used to capture the complete wave for better signal processing analysis. There was a 2&#x202F;ms measurement delay and no trigger delay. The measurement was carried out for continuous recordings until the electrode was inserted and the cable was fixed. There were n&#x202F;=&#x202F;130 iterations for sequential recordings, which were averaged for each recording electrode, yielding a total recording time of 4.5&#x202F;min for all 12 electrodes.</p>
</sec>
<sec id="sec6">
<title>Intra- and postoperative procedures</title>
<p>The CI implantation was performed according to our standards (<xref ref-type="bibr" rid="ref35">Lenarz et al., 2022</xref>). The CI electrode insertion was performed manually or robot-assisted with RobOtol<sup>&#x00AE;</sup> (Collin Medical, Bagneux, France). During the CI electrode insertion, IC potentials were recorded continuously using the most apical electrode contact (C1). The insertion progress, measured by the number of electrodes inserted, was determined visually from the video recording. Partial insertion was sometimes used (<xref ref-type="bibr" rid="ref37">Lenarz et al., 2019</xref>), so the final number of inserted electrodes was not always 12. Partial insertion aims to preserve residual hearing by mimicking a short electrode, while in the event of later degeneration of the residual hearing, the electrode can be fully inserted, and the patient can receive electrical stimulation over the full frequency range.</p>
<p>After insertion, a sequential recording was performed using all electrode contacts separately. The final position of the electrode was evaluated per clinical routine via cone beam CT scan, intraoperatively or one day postoperatively. The location of the electrode within the cochlea was determined using the pre- and postoperative images, and the characteristic frequency region was estimated as described by <xref ref-type="bibr" rid="ref24">Haumann et al. (2024)</xref>. In short, the cochlear lateral wall (LW) was tracked using OsiriX MD (Pixmeo SARL, Switzerland), yielding the 3D spiral shape of the cochlea. The full reconstruction of the scala tympani (ST) was performed by combining the 3D shape of the LW with cross sections of the ST derived from micro CT imaging, as is explained in detail in <xref ref-type="bibr" rid="ref47">Schurzig et al. (2023)</xref>. The path of the electrode array inside the ST was estimated using the average distance between LW and the electrode array, which depends on the array and the insertion angle. The electrode array was virtually inserted so that the specified number of electrodes were located inside the cochlea. The final location of the array in the cochlea after insertion was segmented from the postoperative imaging and registered to the LW using the HelReg method (<xref ref-type="bibr" rid="ref48">Schurzig et al., 2018</xref>), and the tonotopic frequencies were allocated based on an organ of Corti frequency mapping approach (<xref ref-type="bibr" rid="ref26">Helpard et al., 2021</xref>).</p>
<p>The impedances of the intracochlear electrodes and the ground path were recorded per clinical routine using the clinical CI measurement setup by MED-EL. These were evaluated intraoperatively after CI electrode insertion, at the test tone (1&#x2013;3&#x202F;days after surgery), and at the first fitting, which took place 5&#x202F;weeks after surgery.</p>
</sec>
</sec>
<sec id="sec7">
<title>Data analysis</title>
<sec id="sec8">
<title>PTA thresholds</title>
<p>The differences in the low-frequency air conduction thresholds before surgery and at the first fitting appointment were tested for significance at a 5% level with a paired-sample T-test, and the correlation coefficients were calculated using the respective MATLAB functions. Hearing preservation for the different inserted electrode depths (IED) was classified as similar to <xref ref-type="bibr" rid="ref53">Suhling et al. (2016)</xref>. The audiometric pure tone low-frequency hearing threshold (PTA<sub>low</sub>) was calculated as the mean of the air conduction thresholds at 250, 500, and 1000&#x202F;Hz. If no response was observed at the highest stimulated level, the response was set to 10&#x202F;dB above the audiometer limit (105&#x202F;dB HL for 250&#x202F;Hz, 110&#x202F;dB HL for 500&#x202F;Hz, and 110&#x202F;dB HL for 1000&#x202F;Hz). The postoperative hearing preservation was classified into three levels according to the pre- to postoperative PTA<sub>low</sub> shift: a shift of up to 15&#x202F;dB, a shift between 15&#x202F;dB and 30&#x202F;dB, and a shift of more than 30&#x202F;dB.</p>
</sec>
<sec id="sec9">
<title>ECochG recordings</title>
<p>ECochG recordings were averaged from 100 repetitions of the same stimulus. The averaged recordings were then band-pass filtered between 30&#x202F;Hz and 10&#x202F;kHz using a zero-phase, forward-backward second-order Butterworth filter before analysis. Aside from this, no other processing has been conducted. Since all recordings were the same length, the frequency bandwidth for FFT estimation was also consistent. The noise floor for each session was estimated to be the mean amplitudes of three bins on the left and three bins on the right of the stimulus frequency. A recording was considered a response if its amplitude was at least three standard deviations above this noise floor. The entire insertion process was considered one session for continuous recordings performed during insertion. All recordings made under one task were considered one session for sequential, post-insertion measurement.</p>
</sec>
</sec>
<sec id="sec10">
<title>Subject demographics</title>
<p>A total of 10 patients (seven male) with low-frequency residual hearing participated in the study. The mean age was 56&#x202F;years (18&#x2013;77&#x202F;years). Implantation was performed on the right side in six cases. All received a MED-EL Synchrony 2 implant with different electrode lengths (Flex28 in nine cases and FlexSoft in one case) and different IEDs. Their details are given in <xref ref-type="table" rid="tab1">Table 1</xref>.</p>
<table-wrap position="float" id="tab1">
<label>Table 1</label>
<caption>
<p>Details of the subjects and the implanted electrodes.</p>
</caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th align="left" valign="top">ID</th>
<th align="left" valign="top">Electrode</th>
<th align="center" valign="top">Inserted electrode depth (mm)</th>
<th align="center" valign="top">Age at surgery (yrs)</th>
<th align="center" valign="top">Sex</th>
<th align="center" valign="top">Side</th>
<th align="center" valign="top">Duration of hearing impairment (yrs)</th>
<th align="left" valign="top">Etiology</th>
</tr>
</thead>
<tbody>
<tr>
<td align="left" valign="top">S01</td>
<td align="left" valign="top">Flex28</td>
<td align="center" valign="top">20.9</td>
<td align="center" valign="top">51.8</td>
<td align="center" valign="top">f</td>
<td align="center" valign="top">r</td>
<td align="center" valign="top">19</td>
<td align="left" valign="top">unknown/progressive</td>
</tr>
<tr>
<td align="left" valign="top">S02</td>
<td align="left" valign="top">Flex28</td>
<td align="center" valign="top">27.1</td>
<td align="center" valign="top">76.9</td>
<td align="center" valign="top">m</td>
<td align="center" valign="top">l</td>
<td align="center" valign="top">8</td>
<td align="left" valign="top">unknown/progressive</td>
</tr>
<tr>
<td align="left" valign="top">S03</td>
<td align="left" valign="top">Flex28</td>
<td align="center" valign="top">22.3</td>
<td align="center" valign="top">34.9</td>
<td align="center" valign="top">f</td>
<td align="center" valign="top">l</td>
<td align="center" valign="top">32</td>
<td align="left" valign="top">unknown/progressive</td>
</tr>
<tr>
<td align="left" valign="top">S04</td>
<td align="left" valign="top">Flex28</td>
<td align="center" valign="top">28.6</td>
<td align="center" valign="top">18.2</td>
<td align="center" valign="top">m</td>
<td align="center" valign="top">r</td>
<td align="center" valign="top">16</td>
<td align="left" valign="top">unknown/progressive</td>
</tr>
<tr>
<td align="left" valign="top">S05</td>
<td align="left" valign="top">Flex28</td>
<td align="center" valign="top">25.6</td>
<td align="center" valign="top">67.4</td>
<td align="center" valign="top">m</td>
<td align="center" valign="top">l</td>
<td align="center" valign="top">30</td>
<td align="left" valign="top">sudden hearing loss/progressive</td>
</tr>
<tr>
<td align="left" valign="top">S06</td>
<td align="left" valign="top">Flex28</td>
<td align="center" valign="top">28.0</td>
<td align="center" valign="top">36.9</td>
<td align="center" valign="top">m</td>
<td align="center" valign="top">l</td>
<td align="center" valign="top">27</td>
<td align="left" valign="top">sudden hearing loss</td>
</tr>
<tr>
<td align="left" valign="top">S07</td>
<td align="left" valign="top">Flex28</td>
<td align="center" valign="top">26.9</td>
<td align="center" valign="top">61.3</td>
<td align="center" valign="top">m</td>
<td align="center" valign="top">r</td>
<td align="center" valign="top">24</td>
<td align="left" valign="top">unknown</td>
</tr>
<tr>
<td align="left" valign="top">S08</td>
<td align="left" valign="top">Flex28</td>
<td align="center" valign="top">25.9</td>
<td align="center" valign="top">59.7</td>
<td align="center" valign="top">f</td>
<td align="center" valign="top">r</td>
<td align="center" valign="top">7</td>
<td align="left" valign="top">sudden hearing loss/progressive</td>
</tr>
<tr>
<td align="left" valign="top">S09</td>
<td align="left" valign="top">Flex28</td>
<td align="center" valign="top">26.2</td>
<td align="center" valign="top">76.7</td>
<td align="center" valign="top">m</td>
<td align="center" valign="top">r</td>
<td align="center" valign="top">71</td>
<td align="left" valign="top">unknown</td>
</tr>
<tr>
<td align="left" valign="top">S10</td>
<td align="left" valign="top">FlexSoft</td>
<td align="center" valign="top">26.7</td>
<td align="center" valign="top">72.2</td>
<td align="center" valign="top">m</td>
<td align="center" valign="top">r</td>
<td align="center" valign="top">66</td>
<td align="left" valign="top">unknown/progressive</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
</sec>
<sec sec-type="results" id="sec11">
<title>Results</title>
<sec id="sec12">
<title>Hearing preservation as measured by pure tone audiometry</title>
<p>The audiograms of all 10 individuals are given in <xref ref-type="fig" rid="fig1">Figure 1</xref>. The hearing preservation classification as measured by PTA is given in <xref ref-type="table" rid="tab2">Table 2</xref>. Preoperative tympanograms for all 10 cases were unremarkable, showing no evidence of middle ear fluid or negative pressure.</p>
<fig position="float" id="fig1">
<label>Figure 1</label>
<caption>
<p>Air conduction thresholds (AC, in warm coloring, with solid lines and circles) and bone conduction thresholds (BC, in cold coloring, with dashed lines and crosses) for each patient at the preoperative, postoperative, and first fitting (FF) measurement time points. The Inserted Electrode Depth (IED, given in mm) for each patient is also shown. For S03 and S10, the preoperative data point at 750&#x202F;Hz was interpolated visually. In S02, S06, and S09, there was no measurable hearing 1&#x2013;3&#x202F;days postoperatively. In S04, there was no measurable hearing postoperatively or at the first fitting measurement time point.</p>
</caption>
<graphic xlink:href="fnins-18-1530216-g001.tif"/>
</fig>
<table-wrap position="float" id="tab2">
<label>Table 2</label>
<caption>
<p>Hearing preservation classified by low tone air conduction threshold shifts before surgery and at the first fitting appointment, usually 5&#x202F;weeks after surgery, similar to <xref ref-type="bibr" rid="ref53">Suhling et al. (2016)</xref>.</p>
</caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th/>
<th align="center" valign="top" colspan="3">PTA<sub>low, first fit</sub> &#x2013; PTA<sub>low, pre</sub></th>
</tr>
<tr>
<th/>
<th align="center" valign="top">&#x2206; PTA<sub>low</sub>&#x202F;&#x2264;&#x202F;15&#x202F;dB</th>
<th align="center" valign="top">15&#x202F;dB &#x003C; &#x2206; PTA<sub>low</sub>&#x202F;&#x2264;&#x202F;30&#x202F;dB</th>
<th align="center" valign="top">&#x2206; PTA<sub>low</sub> &#x003E; 30&#x202F;dB</th>
</tr>
</thead>
<tbody>
<tr>
<td align="left" valign="middle">IED&#x202F;&#x2264;&#x202F;24<break/><italic>n</italic>&#x202F;=&#x202F;2</td>
<td align="center" valign="middle">1<break/>50%</td>
<td align="center" valign="middle">0<break/>0%</td>
<td align="center" valign="middle">1<break/>50%</td>
</tr>
<tr>
<td align="left" valign="middle">IED&#x202F;&#x003E;&#x202F;24<break/><italic>n</italic>&#x202F;=&#x202F;8</td>
<td align="center" valign="middle">1<break/>12.5%</td>
<td align="center" valign="middle">3<break/>37.5%</td>
<td align="center" valign="middle">4<break/>50%</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<p>The low-frequency PTA was calculated as the mean of the threshold at 250, 500, and 1000&#x202F;Hz.</p>
</table-wrap-foot>
</table-wrap>
<p><xref ref-type="table" rid="tab3">Table 3</xref> details the individual audiometric threshold shifts from pre- to post-surgery. The differences in the low-frequency air conduction thresholds before surgery andat the first fitting appointment were significant, with a correlation coefficient of <italic>r</italic>&#x202F;=&#x202F;0.74&#x002A;.</p>
<table-wrap position="float" id="tab3">
<label>Table 3</label>
<caption>
<p>Inserted electrode depth (IED), audiometric thresholds PTA <sub>low</sub> before surgery and at FF, and hearing preservation group (HP group) classified by audiometric threshold shifts according to <xref ref-type="bibr" rid="ref53">Suhling et al. (2016)</xref>.</p>
</caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th align="left" valign="top" rowspan="2">ID</th>
<th align="center" valign="top" rowspan="2">IED (mm)</th>
<th align="center" valign="top" rowspan="2">PTA<sub>low</sub> (dB HL) before surgery</th>
<th align="center" valign="top" colspan="2">Preop transtymp ECochG threshold (dB nHL)</th>
<th align="center" valign="top" colspan="2">PTA<sub>low</sub> (dB HL) at first fitting appointment and HP group</th>
</tr>
<tr>
<th align="center" valign="top">CM 2&#x202F;kHz</th>
<th align="center" valign="top">CAP click</th>
<th align="center" valign="top">PTA<sub>low</sub> (dB HL) 0.25&#x2013;1&#x202F;kHz</th>
<th align="center" valign="top">HP group</th>
</tr>
</thead>
<tbody>
<tr>
<td align="left" valign="middle">S01</td>
<td align="center" valign="middle">20.9</td>
<td align="center" valign="middle">55.0</td>
<td align="center" valign="middle">70</td>
<td align="center" valign="middle">nr</td>
<td align="center" valign="middle">63.3</td>
<td align="center" valign="middle">0&#x2013;15&#x202F;dB</td>
</tr>
<tr>
<td align="left" valign="middle">S02</td>
<td align="center" valign="middle">27.1</td>
<td align="center" valign="middle">61.7</td>
<td align="center" valign="middle" colspan="2">not possible (medical)</td>
<td align="center" valign="middle">91.7</td>
<td align="center" valign="middle">15&#x2013;30&#x202F;dB</td>
</tr>
<tr>
<td align="left" valign="middle">S03</td>
<td align="center" valign="middle">22.3</td>
<td align="center" valign="middle">61.7</td>
<td align="center" valign="middle">80</td>
<td align="center" valign="middle">nr</td>
<td align="center" valign="middle">103.3</td>
<td align="center" valign="middle">&#x003E;30&#x202F;dB</td>
</tr>
<tr>
<td align="left" valign="middle">S04</td>
<td align="center" valign="middle">28.6</td>
<td align="center" valign="middle">65.0</td>
<td align="center" valign="middle">90</td>
<td align="center" valign="middle">nr</td>
<td align="center" valign="middle">118.3</td>
<td align="center" valign="middle">&#x003E;30&#x202F;dB</td>
</tr>
<tr>
<td align="left" valign="middle">S05</td>
<td align="center" valign="middle">25.6</td>
<td align="center" valign="middle">65.0</td>
<td align="center" valign="middle">60</td>
<td align="center" valign="middle">nr</td>
<td align="center" valign="middle">71.7</td>
<td align="center" valign="middle">0&#x2013;15&#x202F;dB</td>
</tr>
<tr>
<td align="left" valign="middle">S06</td>
<td align="center" valign="middle">28.0</td>
<td align="center" valign="middle">75.0</td>
<td align="center" valign="middle">60</td>
<td align="center" valign="middle">60</td>
<td align="center" valign="middle">118.3</td>
<td align="center" valign="middle">&#x003E;30&#x202F;dB</td>
</tr>
<tr>
<td align="left" valign="middle">S07</td>
<td align="center" valign="middle">26.9</td>
<td align="center" valign="middle">80.0</td>
<td align="center" valign="middle">80</td>
<td align="center" valign="middle">nr</td>
<td align="center" valign="middle">118.3</td>
<td align="center" valign="middle">&#x003E;30&#x202F;dB</td>
</tr>
<tr>
<td align="left" valign="middle">S08</td>
<td align="center" valign="middle">25.9</td>
<td align="center" valign="middle">63.3</td>
<td align="center" valign="middle">70</td>
<td align="center" valign="middle">nr</td>
<td align="center" valign="middle">80.0</td>
<td align="center" valign="middle">15&#x2013;30&#x202F;dB</td>
</tr>
<tr>
<td align="left" valign="middle">S09</td>
<td align="center" valign="middle">26.2</td>
<td align="center" valign="middle">68.3</td>
<td align="center" valign="middle">80</td>
<td align="center" valign="middle">nr</td>
<td align="center" valign="middle">98.3</td>
<td align="center" valign="middle">15&#x2013;30&#x202F;dB</td>
</tr>
<tr>
<td align="left" valign="middle">S10</td>
<td align="center" valign="middle">26.7</td>
<td align="center" valign="middle">71.7</td>
<td align="center" valign="middle" colspan="2">declined by patient</td>
<td align="center" valign="middle">106.7</td>
<td align="center" valign="middle">&#x003E;30&#x202F;dB</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<p>nr - no responses.</p>
</table-wrap-foot>
</table-wrap>
</sec>
<sec id="sec13">
<title>Impedances of the CI electrode contacts</title>
<p>The impedances of the CI electrode contacts are given in <xref ref-type="fig" rid="fig2">Figure 2</xref>.</p>
<fig position="float" id="fig2">
<label>Figure 2</label>
<caption>
<p>Impedances of the CI electrode contacts measured intraoperatively (intraop), at test tone (TT, 1&#x2013;3&#x202F;days after surgery), and at first fitting week (FF, 5&#x202F;weeks after surgery). The impedances are given for all electrode contacts and the ground path (gp). E11@RW means a partial insertion such that the electrode was intentionally inserted partially until electrode contact 11 was positioned at the round window.</p>
</caption>
<graphic xlink:href="fnins-18-1530216-g002.tif"/>
</fig>
</sec>
<sec id="sec14">
<title>Intracochlearly recorded ongoing responses: example cases</title>
<p>Two example cases are given in detail in this section. For subject 1, <xref ref-type="fig" rid="fig3">Figure 3</xref> shows the measurements recorded during electrode insertion, and <xref ref-type="fig" rid="fig4">Figure 4</xref> shows the measurements recorded after electrode insertion. For subject 5, <xref ref-type="fig" rid="fig5">Figure 5</xref> shows the measurements recorded during electrode insertion, and <xref ref-type="fig" rid="fig6">Figure 6</xref> shows the measurements recorded after electrode insertion.</p>
<fig position="float" id="fig3">
<label>Figure 3</label>
<caption>
<p>ECochG measurements performed during insertion in subject 1. Recordings were performed with contact 1. The left panel shows the data in the time domain, with higher wave numbers corresponding to greater electrode insertion depths. The middle panel shows the amplitudes of the wave number in terms of the FFT bin at 500&#x202F;Hz. The red line represents the noise floor, and the amplitude markers are filled dots if the amplitude exceeds the noise level and crosses if the amplitude is lower than the noise level. The colored dashed lines mark the number of inserted electrodes. On the right panel, the response phase is illustrated for the waves with amplitude exceeding the noise level.</p>
</caption>
<graphic xlink:href="fnins-18-1530216-g003.tif"/>
</fig>
<fig position="float" id="fig4">
<label>Figure 4</label>
<caption>
<p>Post-insertion ECochG measurements in subject 1. The left panel shows the data in the time domain, with the number on the right side indicating the recording contact. The middle panel shows the amplitudes of the wave number in terms of the FFT bin at 500&#x202F;Hz. The red line represents the noise floor, and the amplitude markers are filled dots if the amplitude exceeds the noise level and crosses if the amplitude is lower than the noise level. The wave number corresponds to the recording contact. On the right panel, the response phase is illustrated for the waves with amplitude exceeding the noise level.</p>
</caption>
<graphic xlink:href="fnins-18-1530216-g004.tif"/>
</fig>
<fig position="float" id="fig5">
<label>Figure 5</label>
<caption>
<p>ECochG measurements performed during insertion in subject 5. Recordings were performed with contact 1. The left panel shows the data in the time domain, with higher wave numbers corresponding to greater electrode insertion depths. The middle panel shows the amplitudes of the wave number in terms of the FFT bin at 500&#x202F;Hz. The red line represents the noise floor, and the amplitude markers are filled dots if the amplitude exceeds the noise level and crosses if the amplitude is lower than the noise level. The colored dashed lines mark the number of inserted electrodes. On the right panel, the response phase is illustrated for the waves with amplitude exceeding the noise level.</p>
</caption>
<graphic xlink:href="fnins-18-1530216-g005.tif"/>
</fig>
<fig position="float" id="fig6">
<label>Figure 6</label>
<caption>
<p>Post-insertion ECochG measurements in subject 5. The left panel shows the data in the time domain, with the number on the right side indicating the recording contact. The middle panel shows the amplitudes of the wave number in terms of the FFT bin at 500&#x202F;Hz. The red line represents the noise floor, and the amplitude markers are filled dots if the amplitude exceeds the noise level and crosses if the amplitude is lower than the noise level. The wave number corresponds to the recording contact. On the right panel, the response phase is illustrated for the waves with amplitude exceeding the noise level.</p>
</caption>
<graphic xlink:href="fnins-18-1530216-g006.tif"/>
</fig>
</sec>
<sec id="sec15">
<title>Intracochlearly recorded ongoing responses: all data</title>
<p>The measurements for all patients during electrode insertion are given in <xref ref-type="fig" rid="fig7">Figure 7</xref>, and those after insertion are given in <xref ref-type="fig" rid="fig8">Figure 8</xref>.</p>
<fig position="float" id="fig7">
<label>Figure 7</label>
<caption>
<p>ECochG recordings performed during insertion for all 10 subjects. Response amplitudes as a function of insertion time are shown in blue. As the response amplitudes differed between subjects, different scales were chosen for the <italic>y</italic>-axes of each panel. These are indicated by the bars at the bottom left of each panel. The orange stem plots at the top of each panel show the signal&#x2019;s phase. The scaling is indicated in the second <italic>y</italic>-axis to the right. Phase data only show where the amplitude exceeded the noise level (the gray area within each panel). The recordings were performed with the apical-most contact (C1), and the stimulation frequency was 500&#x202F;Hz. The black annotations show the number of inserted contacts at various representative locations, together with the model-based estimated frequency of the organ of Corti where contact 1 was currently located at that time point. The estimated frequency was rounded to the nearest common frequency for audiometric testing.</p>
</caption>
<graphic xlink:href="fnins-18-1530216-g007.tif"/>
</fig>
<fig position="float" id="fig8">
<label>Figure 8</label>
<caption>
<p>ECochG recordings performed after insertion for all 10 subjects. The amplitudes in the time domain for all different electrode contacts are shown in blue. The <italic>x</italic>-axis gives the location of the recording contact and the estimated frequency of the organ of Corti modeled from the postoperative neuroimaging. The vertical bars represent the stimulation frequency of 500&#x202F;Hz. Since the response amplitudes differed between patients, different scales were chosen for the y-axis of each panel, as indicated by the bars at the bottom left of each panel. The same <italic>y</italic>-axis scales were used as in <xref ref-type="fig" rid="fig7">Figure 7</xref>. The orange stem plots at the top of each panel show the signal phase; the scaling is indicated in the second <italic>y</italic>-axis on the right. The phases only show where the amplitude exceeded the noise level (the gray area within each panel).</p>
</caption>
<graphic xlink:href="fnins-18-1530216-g008.tif"/>
</fig>
</sec>
</sec>
<sec sec-type="discussion" id="sec16">
<title>Discussion</title>
<p>In this study, intracochlear ECochG responses were recorded intraoperatively during and after CI electrode insertion in 10 subjects. The electrode position in the cochlea was estimated together with the presumed frequency generator for each patient. Intraoperative recordings were compared to pre- and postoperative PTA thresholds. In an earlier study, intracochlear ECochG recordings were made at specific insertion steps during electrode insertion. After insertion and 6&#x202F;months postoperatively, intracochlear ECochG was recorded at a subset of electrode contacts distributed throughout the cochlea (<xref ref-type="bibr" rid="ref24">Haumann et al., 2024</xref>). In the present study, the resolution of the recordings was improved, as the new study tool of MED-EL allows for continuous recordings during CI electrode insertion. Moreover, all CI electrode contacts were used for the recordings after insertion because this measurement was faster than the former one.</p>
<p>Preservation of residual hearing in the low-frequency range with air conduction was classified into three groups similar to <xref ref-type="bibr" rid="ref53">Suhling et al. (2016)</xref>. At the first fitting week (usually 5&#x202F;weeks after surgery), one subject with an IED of &#x2264;24&#x202F;mm was classified within the best hearing preservation group (0&#x2013;15&#x202F;dB), and one to the worst group (&#x003E;30&#x202F;dB). For the eight subjects with an IED of &#x003E;24&#x202F;mm, one subject was classified to the best group, three to the medium group (15&#x2013;30&#x202F;dB), and four to the worst group (&#x003E;30&#x202F;dB). One of these subjects (S04) also experienced a complete loss of residual hearing. These results are in line with the findings of <xref ref-type="bibr" rid="ref53">Suhling et al. (2016)</xref>. With two subjects (S02 and S03), the CI electrode insertion was performed with robotic assistance using RobOtol<sup>&#x00AE;</sup>. This method allows for extremely slow insertion speeds, as it was previously assumed that slow insertion was generally better for residual hearing preservation. This could not be demonstrated in our data, which is also consistent with recent findings on the behavior of the CI electrode in fluids with a similar viscosity to perilymph (<xref ref-type="bibr" rid="ref17">Fr&#x00F6;hlich et al., 2024</xref>; <xref ref-type="bibr" rid="ref16">Fr&#x00F6;hlich et al., 2024</xref>).</p>
<p>All intraoperative measurements have the disadvantage that they can only be used to investigate processes that occur up to the end of the CI surgery. It is known that implantation can also induce postoperative processes such as inflammation (<xref ref-type="bibr" rid="ref49">Seyyedi and Nadol, 2014</xref>), neo-ossification and fibrosis around the implant (<xref ref-type="bibr" rid="ref41">Quesnel et al., 2016</xref>), and apical degeneration of the stria (<xref ref-type="bibr" rid="ref39">O'Malley et al., 2024</xref>).</p>
<p><xref ref-type="bibr" rid="ref54">Tan et al. (2024)</xref> observed that significant increases in CI electrode impedance were associated with residual hearing loss, suggesting that such impedance elevation could be due to postoperative inflammation. This phenomenon was evident in our observations for subjects S04 and S06, both of whom belonged to the group with the poorest preservation of residual hearing. These were also the two cases with the deepest electrode insertions.</p>
<p>The ECochG measurement for subject S04 showed a notable decrease in amplitude when the surgeon adjusted the grip on the insertion forceps toward the end of the electrode placement (<xref ref-type="fig" rid="fig7">Figure 7</xref>). Under typical circumstances, such a significant drop in amplitude might suggest that no further stimulus responses would be recorded post-insertion. Contrary to expectations, however, the ongoing response (OR) amplitudes recorded after the insertion were actually larger (<xref ref-type="fig" rid="fig8">Figure 8</xref>).</p>
<p>On the other hand, when the amplitude drop occurred during insertion, the frequency generator was crossed according to the calculations (see discussion point below). However, the residual hearing was lost postoperatively in this subject and has not recovered. Therefore, changing the grip of the insertion forceps could also have triggered a postoperative degeneration process, which would be reflected in the increased impedance of the CI electrode. Also, in patient S06, good stimulus responses were measured at the end and after the insertion.</p>
<p>No strong increase in impedances was observed in the other patients. Thus, our study did not observe an increase in impedance without residual hearing loss. For patients who experienced residual hearing loss without an increase in impedance (S03, S07, and S10), this could indicate that the residual hearing was already impacted during the operation (rather than by postoperative inflammation). In patient S07 OR responses were detected at the beginning of the insertion, although they were quite small. In the second half of the insertion, these disappeared and recovered only marginally after insertion, with the residual hearing deteriorating after surgery. This finding is in line with the hypothesis that a drop in response amplitudes during the second half of insertion could indicate trauma and subsequent residual hearing loss (<xref ref-type="bibr" rid="ref32">Koka et al., 2018</xref>; <xref ref-type="bibr" rid="ref50">Sijgers et al., 2021</xref>). In patient S03, no responses above the noise level were detected by the automatic algorithm from the beginning of the measurement. Visually, responses could be observed, but these were noisy and of small amplitude. On this basis, it is possible that the residual hearing of this patient was impaired quite at the beginning of the CI electrode insertion. The amplitude behavior in patient S10 does not fully explain the deterioration in residual hearing, as the amplitude had fallen at the end of the insertion. However, responses were still clearly detectable and were also present postoperatively in a similar amplitude range to during the insertion. In S02, an impedance increase in the basal area of the cochlea was observed postoperatively, but this was lower than in S04 and S06. The residual hearing had also deteriorated significantly in this patient. However, the residual hearing, for example, in S10, also deteriorated significantly by the first fitting without a strong impedance increase. As such, the selectivity of this measure would have to be checked on a larger group of patients. It is also possible that the impedances increased between the test tone and the first fitting, so further measurement time points may need to be scheduled here in future studies.</p>
<p>Previous publications have already described some of the uncertainties of ECochG recordings. For example, ORs can only reflect the status of the inner ear, while the auditory pathway includes more structures (<xref ref-type="bibr" rid="ref14">Fitzpatrick et al., 2014</xref>; <xref ref-type="bibr" rid="ref7">Campbell et al., 2015</xref>; <xref ref-type="bibr" rid="ref22">Haumann et al., 2019</xref>). The different times of the measurements should also be taken into account. Intraoperative measurements can only represent the status at the end of the operation, while the first degenerative processes have already occurred by the time of the postoperative hearing test. Nevertheless, several studies show a good correlation between intracochlearly recorded ORs and audiometric threshold when measured postoperatively on the same day (<xref ref-type="bibr" rid="ref7">Campbell et al., 2015</xref>; <xref ref-type="bibr" rid="ref11">Dalbert et al., 2015</xref>; <xref ref-type="bibr" rid="ref33">Koka et al., 2017</xref>; <xref ref-type="bibr" rid="ref22">Haumann et al., 2019</xref>; <xref ref-type="bibr" rid="ref34">Kr&#x00FC;ger et al., 2020</xref>; <xref ref-type="bibr" rid="ref6">Buechner et al., 2022</xref>). It can, therefore, be assumed that intracochlearly recorded ORs at the end of the surgery reflect the status of residual hearing with clinically acceptable accuracy.</p>
<p>One limitation of intracochlear OR recordings, compared to other methods under investigation, is the uncertainty introduced by changes in the recording location during CI electrode insertion. Currently, it is not fully understood how the amplitude ideally should behave. In theory, the amplitude should rise with ongoing insertion. An amplitude drop can have various causes. For example, a transient drop could be caused by the electrode mechanically blocking or dampening the basilar membrane. Also, the recording electrode may be inserted beyond the characteristic frequency region of the stimulus (<xref ref-type="bibr" rid="ref22">Haumann et al., 2019</xref>; <xref ref-type="bibr" rid="ref6">Buechner et al., 2022</xref>; <xref ref-type="bibr" rid="ref45">Saoji et al., 2023</xref>). In both cases, residual hearing should not be affected.</p>
<p>In contrast, acute trauma to the cochlea should be accompanied by a loss of residual hearing. In an earlier study, the location of the electrode in the cochlea was calculated using clinical neuroimaging, and the corresponding frequency was estimated to determine whether the frequency generator had been passed by the recording electrode (<xref ref-type="bibr" rid="ref24">Haumann et al., 2024</xref>). However, when those experiments were conducted, the clinical MED-EL software could only perform these measurements during discrete insertion steps, so the grid was somewhat coarse. The post-insertion measurement, on the other hand, is purely static, so by comparing the two measurements during and after insertion, it can be distinguished with a certain degree of reliability whether a signal drop is presumably an effect of the changing distance to the generator or whether it could represent an acute trauma. With the MED-EL research software used here, measurements can be carried out continuously during the insertion, and the static measurement post-insertion is also faster so that measurements can be carried out on all 12 contacts.</p>
<p>Because more patients with deeper insertions were included in the current study than in the earlier work, the frequency generator was presumed to be crossed in almost all cases. According to the calculation, the region was not reached in S01 and S09. With S03, the region was presumably reached but not crossed.</p>
<p>In the earlier work, it was already noticeable that in patients where the low-frequency residual hearing was normal or almost normal and the hearing threshold dropped steeply toward the high frequencies, the OR amplitude increased during the insertion or was at its highest after the insertion near the estimated generator frequency. On the contrary, in patients with an almost flat hearing threshold or at least less residual hearing in the low-frequency range and more residual hearing in the high-frequency range, the course of the OR amplitude could not be assigned so clearly.</p>
<p>This effect can be better investigated with continuous measurements or a finer postoperative resolution, which is now possible with the MED-EL tool. Notably, as observed in the data here and in earlier publications, for subjects S01, S03, and S08, the OR amplitude increases toward the estimated generator frequency and peaks after the insertion. The residual low-frequency hearing is normal or almost normal in these patients, and a steep drop-off occurs toward the higher frequencies. Neither in the time course of the insertion nor in the post-insertion measurements, when comparing the recordings on the individual contacts, could a phase shift be observed in these subjects. In contrast, OR amplitudes were found in the medial region of the cochlea in subjects S02, S04, S05, S06, and S09 both during and after insertion. The signal then dropped again to form another peak at or near the expected frequency range. Subject S07 had a second peak in the medial area during insertion, but the signal dropped after insertion, so in the post-insertion recordings, no peaks could be detected. Subject S10 had a peak in the medial region during and after insertion, but there was only a very small peak in the expected frequency range.</p>
<p>The preoperative low-frequency residual hearing was impaired in all the subjects with an OR peak in the medial area, and the audiogram curve was close to flat. There was a phase shift between the peaks in the expected and medial regions of the cochlea of 180 degrees in most of the mentioned subjects. In subject S09, there was also a large phase shift, but here, it occurred between electrode contacts 2 and 3/4. According to the hypothesis that a drop in the first half of insertion is more likely to reflect transient events such as temporary blockage of the basilar membrane, and a drop in the second half of insertion is more consistent with trauma and subsequent residual hearing loss (<xref ref-type="bibr" rid="ref32">Koka et al., 2018</xref>; <xref ref-type="bibr" rid="ref50">Sijgers et al., 2021</xref>), the peak in the medial region should not correspond to a trauma to the cochlea. In our data, there was also no correlation with later hearing preservation.</p>
<p>The peak in the expected region in the described patients also missed the estimated area. It is known that at high stimulation intensities, the position of maximum stimulation of the basilar membrane is shifted (<xref ref-type="bibr" rid="ref27">Honrubia and Ward, 1968</xref>; <xref ref-type="bibr" rid="ref43">Robles and Ruggero, 2001</xref>). This effect can be an octave or even more. However, in the present study, stimulation was performed at the same level, and in the patients with good low-frequency residual hearing, the CF region was covered quite well. As such, this effect cannot satisfactorily explain the differences in our data. What was noticeable in patients with more flat hearing loss is that they probably had more surviving hair cells distributed across the cochlea, while patients with good low-frequency residual hearing and a steep drop-off in the high-frequency range had significantly less residual hearing and, therefore, probably fewer surviving hair cells in the medium or high-frequency range. It is known that more hair cells contribute to ORs (or their CM component) than just those in the area of the response generator (<xref ref-type="bibr" rid="ref8">Cheatham et al., 2011</xref>). It could also be possible that surviving hair cells in the mid-range and high-frequency range contribute to the responses, while in patients with a steep drop-off, hair cells contribute to the stimulus responses mainly in the coarse range of the frequency generator. The travel times of the traveling wave on the basilar membrane could explain the differences in phase between the two peaks, and the interference between both responses could explain the amplitude drop between them. However, based on this theory, one would expect the second peak to be wider (as more hair cells should contribute to the response). This would also need to be further investigated.</p>
<p>A limitation of this study is that stimulation was only performed with a stimulation frequency of 500&#x202F;Hz. At the time of this study, stimulation could only be performed at one frequency during insertion. Here, 500&#x202F;Hz was chosen because many patients have good residual hearing in this frequency range. However, the cochlea can be stimulated much more broadly with a multi-frequency stimulus, and significantly more precise information about the state of the cochlea during electrode insertion could be expected. The new software version from MED-EL allows multi-frequency stimulation with chirps, which is currently being investigated in a new study.</p>
</sec>
<sec sec-type="conclusions" id="sec17">
<title>Conclusion</title>
<p>Our study shows for the first time that the course of the preoperative audiogram seems to influence the course of the ECochG measured intraoperatively. In cases with a typical audiometric threshold for electric-acoustic stimulation with good low-frequency residual hearing, the OR amplitude rose during the insertion. OR amplitudes during and after insertion for the subjects with less preoperative low-frequency hearing showed a second peak in the medial area of the cochlea, which went along with a strong phase shift. Thus, with good low-frequency residual hearing, ECochG curves appear to behave as expected during insertion. In contrast, for those with flat hearing loss there appear to be further effects which need to be investigated in future studies. Based on our new data, we would like to confirm our recommendation to match the position of the electrode in the cochlea with the generator frequency again to rule out a crossing of the generator frequency as the cause of the amplitude drop. Moreover, the course of the preoperative audiogram should be included in the interpretation of the measured amplitude curves.</p>
</sec>
</body>
<back>
<sec sec-type="data-availability" id="sec18">
<title>Data availability statement</title>
<p>The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.</p>
</sec>
<sec sec-type="ethics-statement" id="sec19">
<title>Ethics statement</title>
<p>The studies involving humans were approved by the Ethikkommission der MHH, approval number 10007_BO_S_2021. The studies were conducted in accordance with the local legislation and institutional requirements. The participants provided their written informed consent to participate in this study.</p>
</sec>
<sec sec-type="author-contributions" id="sec20">
<title>Author contributions</title>
<p>SH: Conceptualization, Data curation, Investigation, Methodology, Project administration, Writing &#x2013; original draft. MT: Conceptualization, Data curation, Methodology, Writing &#x2013; review &#x0026; editing. AB: Conceptualization, Methodology, Supervision, Writing &#x2013; review &#x0026; editing. TL: Conceptualization, Methodology, Supervision, Writing &#x2013; review &#x0026; editing. RS: Conceptualization, Investigation, Methodology, Supervision, Writing &#x2013; review &#x0026; editing.</p>
</sec>
<sec sec-type="funding-information" id="sec21">
<title>Funding</title>
<p>The author(s) declare financial support was received for the research, authorship, and/or publication of this article. This study was supported by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) under Germany&#x2019;s Excellence Strategy&#x2014;EXC 2177/1&#x2014;Project ID 390895286.</p>
</sec>
<ack>
<p>We would like to thank Marek Polak, Sidharta Gupta, Onhintz de Olano Dieterich, Daniel Schurzig, and Cornelia Batsoulis from MED-EL for their technical contribution and great support.</p>
</ack>
<sec sec-type="COI-statement" id="sec22">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec sec-type="ai-statement" id="sec23">
<title>Generative AI statement</title>
<p>The authors declare that no Gen AI was used in the creation of this manuscript.</p>
</sec>
<sec sec-type="disclaimer" id="sec24">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ref-list>
<title>References</title>
<ref id="ref1"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Abbas</surname> <given-names>P. J.</given-names></name> <name><surname>Tejani</surname> <given-names>V. D.</given-names></name> <name><surname>Scheperle</surname> <given-names>R. A.</given-names></name> <name><surname>Brown</surname> <given-names>C. J.</given-names></name></person-group> (<year>2017</year>). <article-title>Using neural response telemetry to monitor physiological responses to acoustic stimulation in hybrid cochlear implant users</article-title>. <source>Ear Hear.</source> <volume>38</volume>, <fpage>409</fpage>&#x2013;<lpage>425</lpage>. doi: <pub-id pub-id-type="doi">10.1097/AUD.0000000000000400</pub-id>, PMID: <pub-id pub-id-type="pmid">28085738</pub-id></citation></ref>
<ref id="ref2"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Adunka</surname> <given-names>O. F.</given-names></name> <name><surname>Giardina</surname> <given-names>C. K.</given-names></name> <name><surname>Formeister</surname> <given-names>E. J.</given-names></name> <name><surname>Choudhury</surname> <given-names>B.</given-names></name> <name><surname>Buchman</surname> <given-names>C. A.</given-names></name> <name><surname>Fitzpatrick</surname> <given-names>D. C.</given-names></name></person-group> (<year>2016</year>). <article-title>Round window electrocochleography before and after cochlear implant electrode insertion</article-title>. <source>Laryngoscope</source> <volume>126</volume>, <fpage>1193</fpage>&#x2013;<lpage>1200</lpage>. doi: <pub-id pub-id-type="doi">10.1002/lary.25602</pub-id>, PMID: <pub-id pub-id-type="pmid">26360623</pub-id></citation></ref>
<ref id="ref3"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Barnes</surname> <given-names>J. H.</given-names></name> <name><surname>Yin</surname> <given-names>L. X.</given-names></name> <name><surname>Saoji</surname> <given-names>A. A.</given-names></name> <name><surname>Carlson</surname> <given-names>M. L.</given-names></name></person-group> (<year>2021</year>). <article-title>Electrocochleography in cochlear implantation: development, applications, and future directions</article-title>. <source>World J. Otorhinolaryngol.</source> <volume>7</volume>, <fpage>94</fpage>&#x2013;<lpage>100</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.wjorl.2020.04.006</pub-id>, PMID: <pub-id pub-id-type="pmid">33997718</pub-id></citation></ref>
<ref id="ref4"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Baumgartner</surname> <given-names>W.-D.</given-names></name> <name><surname>Jappel</surname> <given-names>A.</given-names></name> <name><surname>Morera</surname> <given-names>C.</given-names></name> <name><surname>Gst&#x00F6;ttner</surname> <given-names>W.</given-names></name> <name><surname>M&#x00FC;ller</surname> <given-names>J.</given-names></name> <name><surname>Kiefer</surname> <given-names>J.</given-names></name> <etal/></person-group>. (<year>2007</year>). <article-title>Outcomes in adults implanted with the FLEX soft electrode</article-title>. <source>Acta Otolaryngol.</source> <volume>127</volume>, <fpage>579</fpage>&#x2013;<lpage>586</lpage>. doi: <pub-id pub-id-type="doi">10.1080/00016480600987784</pub-id>, PMID: <pub-id pub-id-type="pmid">17503226</pub-id></citation></ref>
<ref id="ref5"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>B&#x00FC;chner</surname> <given-names>A.</given-names></name> <name><surname>Illg</surname> <given-names>A.</given-names></name> <name><surname>Majdani</surname> <given-names>O.</given-names></name> <name><surname>Lenarz</surname> <given-names>T.</given-names></name></person-group> (<year>2017</year>). <article-title>Investigation of the effect of cochlear implant electrode length on speech comprehension in quiet and noise compared with the results with users of electro-acoustic-stimulation, a retrospective analysis</article-title>. <source>PLoS One</source> <volume>12</volume>:<fpage>e0174900</fpage>. doi: <pub-id pub-id-type="doi">10.1371/journal.pone.0174900</pub-id>, PMID: <pub-id pub-id-type="pmid">28505158</pub-id></citation></ref>
<ref id="ref6"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Buechner</surname> <given-names>A.</given-names></name> <name><surname>Bardt</surname> <given-names>M.</given-names></name> <name><surname>Haumann</surname> <given-names>S.</given-names></name> <name><surname>Geissler</surname> <given-names>G.</given-names></name> <name><surname>Salcher</surname> <given-names>R.</given-names></name> <name><surname>Lenarz</surname> <given-names>T.</given-names></name></person-group> (<year>2022</year>). <article-title>Clinical experiences with intraoperative electrocochleography in cochlear implant recipients and its potential to reduce insertion trauma and improve postoperative hearing preservation</article-title>. <source>PLoS One</source> <volume>17</volume>:<fpage>e0266077</fpage>. doi: <pub-id pub-id-type="doi">10.1371/journal.pone.0266077</pub-id>, PMID: <pub-id pub-id-type="pmid">35452461</pub-id></citation></ref>
<ref id="ref7"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Campbell</surname> <given-names>L.</given-names></name> <name><surname>Kaicer</surname> <given-names>A.</given-names></name> <name><surname>Briggs</surname> <given-names>R.</given-names></name> <name><surname>O&#x2019;Leary</surname> <given-names>S.</given-names></name></person-group> (<year>2015</year>). <article-title>Cochlear response telemetry: intracochlear electrocochleography via cochlear implant neural response telemetry pilot study results</article-title>. <source>Otol. Neurotol.</source> <volume>36</volume>, <fpage>399</fpage>&#x2013;<lpage>405</lpage>. doi: <pub-id pub-id-type="doi">10.1097/MAO.0000000000000678</pub-id>, PMID: <pub-id pub-id-type="pmid">25473960</pub-id></citation></ref>
<ref id="ref8"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Cheatham</surname> <given-names>M. A.</given-names></name> <name><surname>Naik</surname> <given-names>K.</given-names></name> <name><surname>Dallos</surname> <given-names>P.</given-names></name></person-group> (<year>2011</year>). <article-title>Using the cochlear microphonic as a tool to evaluate cochlear function in mouse models of hearing</article-title>. <source>J. Assoc. Res. Otolaryngol.</source> <volume>12</volume>, <fpage>113</fpage>&#x2013;<lpage>125</lpage>. doi: <pub-id pub-id-type="doi">10.1007/s10162-010-0240-5</pub-id>, PMID: <pub-id pub-id-type="pmid">20957507</pub-id></citation></ref>
<ref id="ref9"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dalbert</surname> <given-names>A.</given-names></name> <name><surname>Huber</surname> <given-names>A.</given-names></name> <name><surname>Veraguth</surname> <given-names>D.</given-names></name> <name><surname>Roosli</surname> <given-names>C.</given-names></name> <name><surname>Pfiffner</surname> <given-names>F.</given-names></name></person-group> (<year>2016</year>). <article-title>Assessment of cochlear trauma during cochlear implantation using electrocochleography and cone beam computed tomography</article-title>. <source>Otol. Neurotol.</source> <volume>37</volume>, <fpage>446</fpage>&#x2013;<lpage>453</lpage>. doi: <pub-id pub-id-type="doi">10.1097/MAO.0000000000000998</pub-id>, PMID: <pub-id pub-id-type="pmid">26945317</pub-id></citation></ref>
<ref id="ref10"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dalbert</surname> <given-names>A.</given-names></name> <name><surname>Pfiffner</surname> <given-names>F.</given-names></name> <name><surname>Hoesli</surname> <given-names>M.</given-names></name> <name><surname>Koka</surname> <given-names>K.</given-names></name> <name><surname>Veraguth</surname> <given-names>D.</given-names></name> <name><surname>Roosli</surname> <given-names>C.</given-names></name> <etal/></person-group>. (<year>2018</year>). <article-title>Assessment of cochlear function during cochlear implantation by extra-and intracochlear electrocochleography</article-title>. <source>Front. Neurosci.</source> <volume>12</volume>:<fpage>18</fpage>. doi: <pub-id pub-id-type="doi">10.3389/fnins.2018.00018</pub-id>, PMID: <pub-id pub-id-type="pmid">29434534</pub-id></citation></ref>
<ref id="ref11"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dalbert</surname> <given-names>A.</given-names></name> <name><surname>Pfiffner</surname> <given-names>F.</given-names></name> <name><surname>R&#x00F6;&#x00F6;sli</surname> <given-names>C.</given-names></name> <name><surname>Thoele</surname> <given-names>K.</given-names></name> <name><surname>Sim</surname> <given-names>J. H.</given-names></name> <name><surname>Gerig</surname> <given-names>R.</given-names></name> <etal/></person-group>. (<year>2015</year>). <article-title>Extra-and intracochlear electrocochleography in cochlear implant recipients</article-title>. <source>Audiol. Neurotol.</source> <volume>20</volume>, <fpage>339</fpage>&#x2013;<lpage>348</lpage>. doi: <pub-id pub-id-type="doi">10.1159/000438742</pub-id>, PMID: <pub-id pub-id-type="pmid">26340649</pub-id></citation></ref>
<ref id="ref12"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dalbert</surname> <given-names>A.</given-names></name> <name><surname>Sijgers</surname> <given-names>L.</given-names></name> <name><surname>Grosse</surname> <given-names>J.</given-names></name> <name><surname>Veraguth</surname> <given-names>D.</given-names></name> <name><surname>Roosli</surname> <given-names>C.</given-names></name> <name><surname>Huber</surname> <given-names>A.</given-names></name> <etal/></person-group>. (<year>2021</year>). <article-title>Simultaneous intra-and extracochlear electrocochleography during electrode insertion</article-title>. <source>Ear Hear.</source> <volume>42</volume>, <fpage>414</fpage>&#x2013;<lpage>424</lpage>. doi: <pub-id pub-id-type="doi">10.1097/AUD.0000000000000935</pub-id>, PMID: <pub-id pub-id-type="pmid">32826509</pub-id></citation></ref>
<ref id="ref13"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Eggermont</surname> <given-names>J. J.</given-names></name></person-group> (<year>1974</year>). <article-title>Basic principles for electrocochleography</article-title>. <source>Acta Otolaryngol.</source> <volume>77</volume>, <fpage>7</fpage>&#x2013;<lpage>16</lpage>. doi: <pub-id pub-id-type="doi">10.1080/16512251.1974.11675742</pub-id>, PMID: <pub-id pub-id-type="pmid">4525558</pub-id></citation></ref>
<ref id="ref14"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fitzpatrick</surname> <given-names>D. C.</given-names></name> <name><surname>Campbell</surname> <given-names>A.</given-names></name> <name><surname>Choudhury</surname> <given-names>B.</given-names></name> <name><surname>Dillon</surname> <given-names>M.</given-names></name> <name><surname>Forgues</surname> <given-names>M.</given-names></name> <name><surname>Buchman</surname> <given-names>C. A.</given-names></name> <etal/></person-group>. (<year>2014</year>). <article-title>Round window electrocochleography just prior to cochlear implantation: relationship to word recognition outcomes in adults</article-title>. <source>Otol. Neurotol.</source> <volume>35</volume>, <fpage>64</fpage>&#x2013;<lpage>71</lpage>. doi: <pub-id pub-id-type="doi">10.1097/MAO.0000000000000219</pub-id>, PMID: <pub-id pub-id-type="pmid">24317211</pub-id></citation></ref>
<ref id="ref15"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Forgues</surname> <given-names>M.</given-names></name> <name><surname>Koehn</surname> <given-names>H. A.</given-names></name> <name><surname>Dunnon</surname> <given-names>A. K.</given-names></name> <name><surname>Pulver</surname> <given-names>S. H.</given-names></name> <name><surname>Buchman</surname> <given-names>C. A.</given-names></name> <name><surname>Adunka</surname> <given-names>O. F.</given-names></name> <etal/></person-group>. (<year>2014</year>). <article-title>Distinguishing hair cell from neural potentials recorded at the round window</article-title>. <source>J. Neurophysiol.</source> <volume>111</volume>, <fpage>580</fpage>&#x2013;<lpage>593</lpage>. doi: <pub-id pub-id-type="doi">10.1152/jn.00446.2013</pub-id>, PMID: <pub-id pub-id-type="pmid">24133227</pub-id></citation></ref>
<ref id="ref16"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fr&#x00F6;hlich</surname> <given-names>M.</given-names></name> <name><surname>Deutz</surname> <given-names>J.</given-names></name> <name><surname>Wangenheim</surname> <given-names>M.</given-names></name> <name><surname>Rau</surname> <given-names>T. S.</given-names></name> <name><surname>Kral</surname> <given-names>A.</given-names></name> <name><surname>Lenarz</surname> <given-names>T.</given-names></name> <etal/></person-group>. (<year>2024</year>). <article-title>The role of pressure and friction forces in automated insertion of Cochlear implants</article-title>. <source>Front. Neurol.</source> <volume>15</volume>:<fpage>1430694</fpage>. doi: <pub-id pub-id-type="doi">10.3389/fneur.2024.1430694</pub-id></citation></ref>
<ref id="ref17"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fr&#x00F6;hlich</surname> <given-names>M.</given-names></name> <name><surname>Schurzig</surname> <given-names>D.</given-names></name> <name><surname>Rau</surname> <given-names>T. S.</given-names></name> <name><surname>Lenarz</surname> <given-names>T.</given-names></name></person-group> (<year>2024</year>). <article-title>On the interdependence of insertion forces, insertion speed, and lubrication: aspects to consider when testing cochlear implant electrodes</article-title>. <source>PLoS One</source> <volume>19</volume>:<fpage>e0295121</fpage>. doi: <pub-id pub-id-type="doi">10.1371/journal.pone.0295121</pub-id>, PMID: <pub-id pub-id-type="pmid">38266033</pub-id></citation></ref>
<ref id="ref18"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gantz</surname> <given-names>B. J.</given-names></name> <name><surname>Dunn</surname> <given-names>C. C.</given-names></name> <name><surname>Oleson</surname> <given-names>J.</given-names></name> <name><surname>Hansen</surname> <given-names>M. R.</given-names></name></person-group> (<year>2018</year>). <article-title>Acoustic plus electric speech processing: long-term results</article-title>. <source>Laryngoscope</source> <volume>128</volume>, <fpage>473</fpage>&#x2013;<lpage>481</lpage>. doi: <pub-id pub-id-type="doi">10.1002/lary.26669</pub-id>, PMID: <pub-id pub-id-type="pmid">28543270</pub-id></citation></ref>
<ref id="ref19"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gantz</surname> <given-names>B. J.</given-names></name> <name><surname>Turner</surname> <given-names>C.</given-names></name> <name><surname>Gfeller</surname> <given-names>K. E.</given-names></name> <name><surname>Lowder</surname> <given-names>M. W.</given-names></name></person-group> (<year>2005</year>). <article-title>Preservation of hearing in cochlear implant surgery: advantages of combined electrical and acoustical speech processing</article-title>. <source>Laryngoscope</source> <volume>115</volume>, <fpage>796</fpage>&#x2013;<lpage>802</lpage>. doi: <pub-id pub-id-type="doi">10.1097/01.MLG.0000157695.07536.D2</pub-id>, PMID: <pub-id pub-id-type="pmid">15867642</pub-id></citation></ref>
<ref id="ref20"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Giardina</surname> <given-names>C. K.</given-names></name> <name><surname>Brown</surname> <given-names>K. D.</given-names></name> <name><surname>Adunka</surname> <given-names>O. F.</given-names></name> <name><surname>Buchman</surname> <given-names>C. A.</given-names></name> <name><surname>Hutson</surname> <given-names>K. A.</given-names></name> <name><surname>Pillsbury</surname> <given-names>H. C.</given-names></name> <etal/></person-group>. (<year>2019</year>). <article-title>Intracochlear electrocochleography: response patterns during cochlear implantation and hearing preservation</article-title>. <source>Ear Hear.</source> <volume>40</volume>, <fpage>833</fpage>&#x2013;<lpage>848</lpage>. doi: <pub-id pub-id-type="doi">10.1097/AUD.0000000000000659</pub-id>, PMID: <pub-id pub-id-type="pmid">30335669</pub-id></citation></ref>
<ref id="ref21"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Greisiger</surname> <given-names>R.</given-names></name> <name><surname>Bester</surname> <given-names>C.</given-names></name> <name><surname>S&#x00F8;rensen</surname> <given-names>T.</given-names></name> <name><surname>Korslund</surname> <given-names>H.</given-names></name> <name><surname>Bunne</surname> <given-names>M.</given-names></name> <name><surname>O'Leary</surname> <given-names>S.</given-names></name> <etal/></person-group>. (<year>2024</year>). <article-title>Intraoperative measured electrocochleography and fluoroscopy video to detect cochlea trauma</article-title>. <source>Otol. Neurotol.</source> <volume>45</volume>, <fpage>36</fpage>&#x2013;<lpage>45</lpage>. doi: <pub-id pub-id-type="doi">10.1097/MAO.0000000000004055</pub-id>, PMID: <pub-id pub-id-type="pmid">38085760</pub-id></citation></ref>
<ref id="ref22"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Haumann</surname> <given-names>S.</given-names></name> <name><surname>Imsiecke</surname> <given-names>M.</given-names></name> <name><surname>Bauernfeind</surname> <given-names>G.</given-names></name> <name><surname>B&#x00FC;chner</surname> <given-names>A.</given-names></name> <name><surname>Helmstaedter</surname> <given-names>V.</given-names></name> <name><surname>Lenarz</surname> <given-names>T.</given-names></name> <etal/></person-group>. (<year>2019</year>). <article-title>Monitoring of the inner ear function during and after cochlear implant insertion using electrocochleography</article-title>. <source>Trends Hear.</source> <volume>23</volume>:<fpage>2331216519833567</fpage>. doi: <pub-id pub-id-type="doi">10.1177/2331216519833567</pub-id>, PMID: <pub-id pub-id-type="pmid">30909815</pub-id></citation></ref>
<ref id="ref23"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Haumann</surname> <given-names>S.</given-names></name> <name><surname>Mynarek</surname> <given-names>M.</given-names></name> <name><surname>Maier</surname> <given-names>H.</given-names></name> <name><surname>Helmstaedter</surname> <given-names>V.</given-names></name> <name><surname>B&#x00FC;chner</surname> <given-names>A.</given-names></name> <name><surname>Lenarz</surname> <given-names>T.</given-names></name> <etal/></person-group>. (<year>2024</year>). <article-title>Does intraoperative extracochlear electrocochleography correlate with postoperative audiometric hearing thresholds in cochlea implant surgery &#x2013; a retrospective analysis on Cochlear monitoring</article-title>. <source>Trends Hear.</source> <volume>28</volume>, <fpage>1</fpage>&#x2013;<lpage>22</lpage>. doi: <pub-id pub-id-type="doi">10.1177/23312165241252240</pub-id>, PMID: <pub-id pub-id-type="pmid">38715410</pub-id></citation></ref>
<ref id="ref24"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Haumann</surname> <given-names>S.</given-names></name> <name><surname>Timm</surname> <given-names>M. E.</given-names></name> <name><surname>B&#x00FC;chner</surname> <given-names>A.</given-names></name> <name><surname>Lenarz</surname> <given-names>T.</given-names></name> <name><surname>Salcher</surname> <given-names>R. B.</given-names></name></person-group> (<year>2024</year>). <article-title>Intracochlear recording of electrocochleography during and after cochlear implant insertion dependent on the location in the cochlea</article-title>. <source>Trends Hear.</source> <volume>28</volume>, <fpage>1</fpage>&#x2013;<lpage>16</lpage>. doi: <pub-id pub-id-type="doi">10.1177/23312165241248973</pub-id>, PMID: <pub-id pub-id-type="pmid">38717441</pub-id></citation></ref>
<ref id="ref25"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Helbig</surname> <given-names>S.</given-names></name> <name><surname>Van de Heyning</surname> <given-names>P.</given-names></name> <name><surname>Kiefer</surname> <given-names>J.</given-names></name> <name><surname>Baumann</surname> <given-names>U.</given-names></name> <name><surname>Kleine-Punte</surname> <given-names>A.</given-names></name> <name><surname>Brockmeier</surname> <given-names>H.</given-names></name> <etal/></person-group>. (<year>2011</year>). <article-title>Combined electric acoustic stimulation with the PULSARCI100 implant system using the FLEXEAS electrode array</article-title>. <source>Acta Otolaryngol.</source> <volume>131</volume>, <fpage>585</fpage>&#x2013;<lpage>595</lpage>. doi: <pub-id pub-id-type="doi">10.3109/00016489.2010.544327</pub-id>, PMID: <pub-id pub-id-type="pmid">21281057</pub-id></citation></ref>
<ref id="ref26"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Helpard</surname> <given-names>L.</given-names></name> <name><surname>Li</surname> <given-names>H.</given-names></name> <name><surname>Rohani</surname> <given-names>S. A.</given-names></name> <name><surname>Zhu</surname> <given-names>N.</given-names></name> <name><surname>Rask-Andersen</surname> <given-names>H.</given-names></name> <name><surname>Agrawal</surname> <given-names>S.</given-names></name> <etal/></person-group>. (<year>2021</year>). <article-title>An approach for individualized cochlear frequency mapping determined from 3D synchrotron radiation phase-contrast imaging</article-title>. <source>IEEE Trans. Biomed. Eng.</source> <volume>68</volume>, <fpage>3602</fpage>&#x2013;<lpage>3611</lpage>. doi: <pub-id pub-id-type="doi">10.1109/TBME.2021.3080116</pub-id>, PMID: <pub-id pub-id-type="pmid">33983877</pub-id></citation></ref>
<ref id="ref27"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Honrubia</surname> <given-names>V.</given-names></name> <name><surname>Ward</surname> <given-names>P. H.</given-names></name></person-group> (<year>1968</year>). <article-title>Longitudinal distribution of the cochlear microphonics inside the cochlear duct (guinea pig)</article-title>. <source>J. Acoust. Soc. Am.</source> <volume>44</volume>, <fpage>951</fpage>&#x2013;<lpage>958</lpage>. doi: <pub-id pub-id-type="doi">10.1121/1.1911234</pub-id>, PMID: <pub-id pub-id-type="pmid">5683661</pub-id></citation></ref>
<ref id="ref28"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Incerti</surname> <given-names>P. V.</given-names></name> <name><surname>Ching</surname> <given-names>T. Y.</given-names></name> <name><surname>Cowan</surname> <given-names>R.</given-names></name></person-group> (<year>2013</year>). <article-title>A systematic review of electric-acoustic stimulation: device fitting ranges, outcomes, and clinical fitting practices</article-title>. <source>Trends Amplif.</source> <volume>17</volume>, <fpage>3</fpage>&#x2013;<lpage>26</lpage>. doi: <pub-id pub-id-type="doi">10.1177/1084713813480857</pub-id>, PMID: <pub-id pub-id-type="pmid">23539259</pub-id></citation></ref>
<ref id="ref29"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>James</surname> <given-names>C.</given-names></name> <name><surname>Albegger</surname> <given-names>K.</given-names></name> <name><surname>Battmer</surname> <given-names>R.</given-names></name> <name><surname>Burdo</surname> <given-names>S.</given-names></name> <name><surname>Deggouj</surname> <given-names>N.</given-names></name> <name><surname>Deguine</surname> <given-names>O.</given-names></name></person-group> (<year>2005</year>). <article-title>Preservation of residual hearing with cochlear implantation: how and why</article-title>. <source>Acta Otolaryngol.</source> <volume>125</volume>, <fpage>481</fpage>&#x2013;<lpage>491</lpage>. doi: <pub-id pub-id-type="doi">10.1080/00016480510026197</pub-id>, PMID: <pub-id pub-id-type="pmid">16092537</pub-id></citation></ref>
<ref id="ref30"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kim</surname> <given-names>J.-S.</given-names></name></person-group> (<year>2020</year>). <article-title>Electrocochleography in Cochlear implant users with residual acoustic hearing: a systematic review</article-title>. <source>Int. J. Environ. Res. Public Health</source> <volume>17</volume>:<fpage>7043</fpage>. doi: <pub-id pub-id-type="doi">10.3390/ijerph17197043</pub-id>, PMID: <pub-id pub-id-type="pmid">32993065</pub-id></citation></ref>
<ref id="ref31"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kim</surname> <given-names>J.-S.</given-names></name></person-group> (<year>2024</year>). <article-title>Clinical applications of intracochlear electrocochleography in cochlear implant users with residual acoustic hearing</article-title>. <source>J. Audiol. Otol.</source> <volume>28</volume>, <fpage>100</fpage>&#x2013;<lpage>106</lpage>. doi: <pub-id pub-id-type="doi">10.7874/jao.2024.00129</pub-id>, PMID: <pub-id pub-id-type="pmid">38695055</pub-id></citation></ref>
<ref id="ref32"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Koka</surname> <given-names>K.</given-names></name> <name><surname>Riggs</surname> <given-names>W. J.</given-names></name> <name><surname>Dwyer</surname> <given-names>R.</given-names></name> <name><surname>Holder</surname> <given-names>J. T.</given-names></name> <name><surname>Noble</surname> <given-names>J. H.</given-names></name> <name><surname>Dawant</surname> <given-names>B. M.</given-names></name></person-group> (<year>2018</year>). <article-title>Intra-cochlear electrocochleography during cochear implant electrode insertion is predictive of final scalar location</article-title>. <source>Otol. Neurotol.</source> <volume>39</volume>:<fpage>e654</fpage>, &#x2013;<lpage>e659</lpage>. doi: <pub-id pub-id-type="doi">10.1097/MAO.0000000000001906</pub-id>, PMID: <pub-id pub-id-type="pmid">30113557</pub-id></citation></ref>
<ref id="ref33"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Koka</surname> <given-names>K.</given-names></name> <name><surname>Saoji</surname> <given-names>A. A.</given-names></name> <name><surname>Litvak</surname> <given-names>L. M.</given-names></name></person-group> (<year>2017</year>). <article-title>Electrocochleography in cochlear implant recipients with residual hearing: comparison with audiometric thresholds</article-title>. <source>Ear Hear.</source> <volume>38</volume>, <fpage>e161</fpage>&#x2013;<lpage>e167</lpage>. doi: <pub-id pub-id-type="doi">10.1097/AUD.0000000000000385</pub-id>, PMID: <pub-id pub-id-type="pmid">27879487</pub-id></citation></ref>
<ref id="ref34"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kr&#x00FC;ger</surname> <given-names>B.</given-names></name> <name><surname>B&#x00FC;chner</surname> <given-names>A.</given-names></name> <name><surname>Lenarz</surname> <given-names>T.</given-names></name> <name><surname>Nogueira</surname> <given-names>W.</given-names></name></person-group> (<year>2020</year>). <article-title>Amplitude growth of intracochlear electrocochleography in cochlear implant users with residual hearing</article-title>. <source>J. Acoust. Soc. Am.</source> <volume>147</volume>, <fpage>1147</fpage>&#x2013;<lpage>1162</lpage>. doi: <pub-id pub-id-type="doi">10.1121/10.0000744</pub-id>, PMID: <pub-id pub-id-type="pmid">32113296</pub-id></citation></ref>
<ref id="ref35"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lenarz</surname> <given-names>T.</given-names></name> <name><surname>B&#x00FC;chner</surname> <given-names>A.</given-names></name> <name><surname>Illg</surname> <given-names>A.</given-names></name></person-group> (<year>2022</year>). <article-title>Cochlear implantation: concept, results outcomes and quality of life</article-title>. <source>Laryngo-Rhino-Otologie</source> <volume>101</volume>, <fpage>S36</fpage>&#x2013;<lpage>S78</lpage>. doi: <pub-id pub-id-type="doi">10.1055/a-1731-9321</pub-id>, PMID: <pub-id pub-id-type="pmid">35605612</pub-id></citation></ref>
<ref id="ref36"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lenarz</surname> <given-names>T.</given-names></name> <name><surname>St&#x00F6;ver</surname> <given-names>T.</given-names></name> <name><surname>Buechner</surname> <given-names>A.</given-names></name> <name><surname>Lesinski-Schiedat</surname> <given-names>A.</given-names></name> <name><surname>Patrick</surname> <given-names>J.</given-names></name> <name><surname>Pesch</surname> <given-names>J.</given-names></name></person-group> (<year>2009</year>). <article-title>Hearing conservation surgery using the hybrid-L electrode</article-title>. <source>Audiol. Neurotol.</source> <volume>14</volume>, <fpage>22</fpage>&#x2013;<lpage>31</lpage>. doi: <pub-id pub-id-type="doi">10.1159/000206492</pub-id></citation></ref>
<ref id="ref37"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lenarz</surname> <given-names>T.</given-names></name> <name><surname>Timm</surname> <given-names>M. E.</given-names></name> <name><surname>Salcher</surname> <given-names>R.</given-names></name> <name><surname>B&#x00FC;chner</surname> <given-names>A.</given-names></name></person-group> (<year>2019</year>). <article-title>Individual hearing preservation cochlear implantation using the concept of partial insertion</article-title>. <source>Otol. Neurotol.</source> <volume>40</volume>, <fpage>e326</fpage>&#x2013;<lpage>e335</lpage>. doi: <pub-id pub-id-type="doi">10.1097/MAO.0000000000002127</pub-id>, PMID: <pub-id pub-id-type="pmid">30741914</pub-id></citation></ref>
<ref id="ref38"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>O&#x2019;Leary</surname> <given-names>S.</given-names></name> <name><surname>Mylanus</surname> <given-names>E.</given-names></name> <name><surname>Venail</surname> <given-names>F.</given-names></name> <name><surname>Lenarz</surname> <given-names>T.</given-names></name> <name><surname>Birman</surname> <given-names>C.</given-names></name> <name><surname>Di Lella</surname> <given-names>F.</given-names></name></person-group> (<year>2023</year>). <article-title>Monitoring cochlear health with intracochlear electrocochleography during cochlear implantation: findings from an international clinical investigation</article-title>. <source>Ear Hear.</source> <volume>44</volume>, <fpage>358</fpage>&#x2013;<lpage>370</lpage>. doi: <pub-id pub-id-type="doi">10.1097/AUD.0000000000001288</pub-id>, PMID: <pub-id pub-id-type="pmid">36395515</pub-id></citation></ref>
<ref id="ref39"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>O'Malley</surname> <given-names>J. T.</given-names></name> <name><surname>Wu</surname> <given-names>P.-Z.</given-names></name> <name><surname>Kaur</surname> <given-names>C.</given-names></name> <name><surname>Gantz</surname> <given-names>B. J.</given-names></name> <name><surname>Hansen</surname> <given-names>M. R.</given-names></name> <name><surname>Quesnel</surname> <given-names>A. M.</given-names></name> <etal/></person-group>. (<year>2024</year>). <article-title>Delayed hearing loss after cochlear implantation: re-evaluating the role of hair cell degeneration</article-title>. <source>Hear. Res.</source> <volume>447</volume>:<fpage>109024</fpage>. doi: <pub-id pub-id-type="doi">10.1016/j.heares.2024.109024</pub-id>, PMID: <pub-id pub-id-type="pmid">38735179</pub-id></citation></ref>
<ref id="ref40"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Panario</surname> <given-names>J.</given-names></name> <name><surname>Bester</surname> <given-names>C.</given-names></name> <name><surname>O&#x2019;Leary</surname> <given-names>S.</given-names></name></person-group> (<year>2024</year>). <article-title>Predicting postoperative speech perception and audiometric thresholds using intracochlear electrocochleography in cochlear implant recipients</article-title>. <source>Ear Hear.</source> <volume>149</volume>, <fpage>1120</fpage>&#x2013;<lpage>1129</lpage>. doi: <pub-id pub-id-type="doi">10.1001/jamaoto.2023.2988</pub-id>, PMID: <pub-id pub-id-type="pmid">37856099</pub-id></citation></ref>
<ref id="ref41"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Quesnel</surname> <given-names>A. M.</given-names></name> <name><surname>Nakajima</surname> <given-names>H. H.</given-names></name> <name><surname>Rosowski</surname> <given-names>J. J.</given-names></name> <name><surname>Hansen</surname> <given-names>M. R.</given-names></name> <name><surname>Gantz</surname> <given-names>B. J.</given-names></name> <name><surname>Nadol</surname> <given-names>J. B.</given-names> <suffix>Jr.</suffix></name></person-group> (<year>2016</year>). <article-title>Delayed loss of hearing after hearing preservation cochlear implantation: human temporal bone pathology and implications for etiology</article-title>. <source>Hear. Res.</source> <volume>333</volume>, <fpage>225</fpage>&#x2013;<lpage>234</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.heares.2015.08.018</pub-id>, PMID: <pub-id pub-id-type="pmid">26341474</pub-id></citation></ref>
<ref id="ref42"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Radeloff</surname> <given-names>A.</given-names></name> <name><surname>Shehata-Dieler</surname> <given-names>W.</given-names></name> <name><surname>Scherzed</surname> <given-names>A.</given-names></name> <name><surname>Rak</surname> <given-names>K.</given-names></name> <name><surname>Harnisch</surname> <given-names>W.</given-names></name> <name><surname>Hagen</surname> <given-names>R.</given-names></name> <etal/></person-group>. (<year>2012</year>). <article-title>Intraoperative monitoring using cochlear microphonics in cochlear implant patients with residual hearing</article-title>. <source>Otol. Neurotol.</source> <volume>33</volume>, <fpage>348</fpage>&#x2013;<lpage>354</lpage>. doi: <pub-id pub-id-type="doi">10.1097/MAO.0b013e318248ea86</pub-id>, PMID: <pub-id pub-id-type="pmid">22377649</pub-id></citation></ref>
<ref id="ref43"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Robles</surname> <given-names>L.</given-names></name> <name><surname>Ruggero</surname> <given-names>M. A.</given-names></name></person-group> (<year>2001</year>). <article-title>Mechanics of the mammalian cochlea</article-title>. <source>Physiol. Rev.</source> <volume>81</volume>, <fpage>1305</fpage>&#x2013;<lpage>1352</lpage>. doi: <pub-id pub-id-type="doi">10.1152/physrev.2001.81.3.1305</pub-id>, PMID: <pub-id pub-id-type="pmid">11427697</pub-id></citation></ref>
<ref id="ref44"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Roland</surname> <given-names>J. T.</given-names> <suffix>Jr.</suffix></name> <name><surname>Gantz</surname> <given-names>B. J.</given-names></name> <name><surname>Waltzman</surname> <given-names>S. B.</given-names></name> <name><surname>Parkinson</surname> <given-names>A. J.</given-names></name></person-group> (<year>2018</year>). <article-title>Long-term outcomes of cochlear implantation in patients with high-frequency hearing loss</article-title>. <source>Laryngoscope</source> <volume>128</volume>, <fpage>1939</fpage>&#x2013;<lpage>1945</lpage>. doi: <pub-id pub-id-type="doi">10.1002/lary.27073</pub-id>, PMID: <pub-id pub-id-type="pmid">29330858</pub-id></citation></ref>
<ref id="ref45"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Saoji</surname> <given-names>A. A.</given-names></name> <name><surname>Graham</surname> <given-names>M. K.</given-names></name> <name><surname>Adkins</surname> <given-names>W. J.</given-names></name> <name><surname>Koka</surname> <given-names>K.</given-names></name> <name><surname>Carlson</surname> <given-names>M. L.</given-names></name> <name><surname>Neff</surname> <given-names>B. A.</given-names></name> <etal/></person-group>. (<year>2023</year>). <article-title>Multi-frequency electrocochleography and electrode scan to identify electrode insertion trauma during cochlear implantation</article-title>. <source>Brain Sci.</source> <volume>13</volume>:<fpage>330</fpage>. doi: <pub-id pub-id-type="doi">10.3390/brainsci13020330</pub-id>, PMID: <pub-id pub-id-type="pmid">36831873</pub-id></citation></ref>
<ref id="ref46"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Saoji</surname> <given-names>A. A.</given-names></name> <name><surname>Patel</surname> <given-names>N. S.</given-names></name> <name><surname>Carlson</surname> <given-names>M. L.</given-names></name> <name><surname>Neff</surname> <given-names>B. A.</given-names></name> <name><surname>Koka</surname> <given-names>K.</given-names></name> <name><surname>Tarigoppula</surname> <given-names>V. S.</given-names></name> <etal/></person-group>. (<year>2019</year>). <article-title>Multi-frequency electrocochleography measurements can be used to monitor and optimize electrode placement during cochlear implant surgery</article-title>. <source>Otol. Neurotol.</source> <volume>40</volume>, <fpage>1287</fpage>&#x2013;<lpage>1291</lpage>. doi: <pub-id pub-id-type="doi">10.1097/MAO.0000000000002406</pub-id>, PMID: <pub-id pub-id-type="pmid">31644474</pub-id></citation></ref>
<ref id="ref47"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Schurzig</surname> <given-names>D.</given-names></name> <name><surname>Repp</surname> <given-names>F.</given-names></name> <name><surname>Timm</surname> <given-names>M. E.</given-names></name> <name><surname>Batsoulis</surname> <given-names>C.</given-names></name> <name><surname>Lenarz</surname> <given-names>T.</given-names></name> <name><surname>Kral</surname> <given-names>A.</given-names></name></person-group> (<year>2023</year>). <article-title>Virtual cochlear implantation for personalized rehabilitation of profound hearing loss</article-title>. <source>Hear. Res.</source> <volume>429</volume>:<fpage>108687</fpage>. doi: <pub-id pub-id-type="doi">10.1016/j.heares.2022.108687</pub-id>, PMID: <pub-id pub-id-type="pmid">36638762</pub-id></citation></ref>
<ref id="ref48"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Schurzig</surname> <given-names>D.</given-names></name> <name><surname>Timm</surname> <given-names>M. E.</given-names></name> <name><surname>Batsoulis</surname> <given-names>C.</given-names></name> <name><surname>John</surname> <given-names>S.</given-names></name> <name><surname>Lenarz</surname> <given-names>T.</given-names></name></person-group> (<year>2018</year>). <article-title>Analysis of different approaches for clinical cochlear coverage evaluation after cochlear implantation</article-title>. <source>Otol. Neurotol.</source> <volume>39</volume>, <fpage>e642</fpage>&#x2013;<lpage>e650</lpage>. doi: <pub-id pub-id-type="doi">10.1097/MAO.0000000000001904</pub-id>, PMID: <pub-id pub-id-type="pmid">30015749</pub-id></citation></ref>
<ref id="ref49"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Seyyedi</surname> <given-names>M.</given-names></name> <name><surname>Nadol</surname> <given-names>J. B.</given-names> <suffix>Jr.</suffix></name></person-group> (<year>2014</year>). <article-title>Intracochlear inflammatory response to cochlear implant electrodes in the human</article-title>. <source>Otol. Neurotol.</source> <volume>35</volume>, <fpage>1545</fpage>&#x2013;<lpage>1551</lpage>. doi: <pub-id pub-id-type="doi">10.1097/MAO.0000000000000540</pub-id>, PMID: <pub-id pub-id-type="pmid">25122600</pub-id></citation></ref>
<ref id="ref50"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sijgers</surname> <given-names>L.</given-names></name> <name><surname>Pfiffner</surname> <given-names>F.</given-names></name> <name><surname>Grosse</surname> <given-names>J.</given-names></name> <name><surname>Dillier</surname> <given-names>N.</given-names></name> <name><surname>Koka</surname> <given-names>K.</given-names></name> <name><surname>R&#x00F6;&#x00F6;sli</surname> <given-names>C.</given-names></name> <etal/></person-group>. (<year>2021</year>). <article-title>Simultaneous intra-and extracochlear electrocochleography during cochlear implantation to enhance response interpretation</article-title>. <source>Trends Hear.</source> <volume>25</volume>:<fpage>2331216521990594</fpage>. doi: <pub-id pub-id-type="doi">10.1177/2331216521990594</pub-id>, PMID: <pub-id pub-id-type="pmid">33710919</pub-id></citation></ref>
<ref id="ref51"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sijgers</surname> <given-names>L.</given-names></name> <name><surname>Sorensen</surname> <given-names>T.</given-names></name> <name><surname>Soulby</surname> <given-names>A.</given-names></name> <name><surname>Boyle</surname> <given-names>P.</given-names></name> <name><surname>Dalbert</surname> <given-names>A.</given-names></name> <name><surname>R&#x00F6;&#x00F6;sli</surname> <given-names>C.</given-names></name></person-group> (<year>2023</year>). <article-title>Classification of acoustic hearing preservation after cochlear implantation using electrocochleography</article-title>. <source>Trends Hear.</source> <volume>27</volume>:<fpage>23312165231220997</fpage>. doi: <pub-id pub-id-type="doi">10.1177/23312165231220997</pub-id>, PMID: <pub-id pub-id-type="pmid">38105510</pub-id></citation></ref>
<ref id="ref52"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Snyder</surname> <given-names>R. L.</given-names></name> <name><surname>Schreiner</surname> <given-names>C. E.</given-names></name></person-group> (<year>1984</year>). <article-title>The auditory neurophonic: basic properties</article-title>. <source>Hear. Res.</source> <volume>15</volume>, <fpage>261</fpage>&#x2013;<lpage>280</lpage>. doi: <pub-id pub-id-type="doi">10.1016/0378-5955(84)90033-9</pub-id>, PMID: <pub-id pub-id-type="pmid">6501114</pub-id></citation></ref>
<ref id="ref53"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Suhling</surname> <given-names>M.-C.</given-names></name> <name><surname>Majdani</surname> <given-names>O.</given-names></name> <name><surname>Salcher</surname> <given-names>R.</given-names></name> <name><surname>Leifholz</surname> <given-names>M.</given-names></name> <name><surname>B&#x00FC;chner</surname> <given-names>A.</given-names></name> <name><surname>Lesinski-Schiedat</surname> <given-names>A.</given-names></name> <etal/></person-group>. (<year>2016</year>). <article-title>The impact of electrode array length on hearing preservation in cochlear implantation</article-title>. <source>Otol. Neurotol.</source> <volume>37</volume>, <fpage>1006</fpage>&#x2013;<lpage>1015</lpage>. doi: <pub-id pub-id-type="doi">10.1097/MAO.0000000000001110</pub-id>, PMID: <pub-id pub-id-type="pmid">27309713</pub-id></citation></ref>
<ref id="ref54"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tan</surname> <given-names>E.</given-names></name> <name><surname>Bester</surname> <given-names>C.</given-names></name> <name><surname>Collins</surname> <given-names>A.</given-names></name> <name><surname>Razmovski</surname> <given-names>T.</given-names></name> <name><surname>O'Leary</surname> <given-names>S.</given-names></name></person-group> (<year>2024</year>). <article-title>Four-point impedance: a potential biomarker for residual hearing after cochlear implantation</article-title>. <source>Otol. Neurotol.</source> <volume>45</volume>, <fpage>e315</fpage>&#x2013;<lpage>e321</lpage>. doi: <pub-id pub-id-type="doi">10.1097/MAO.0000000000004153</pub-id>, PMID: <pub-id pub-id-type="pmid">38478410</pub-id></citation></ref>
<ref id="ref55"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Timm</surname> <given-names>M. E.</given-names></name> <name><surname>Majdani</surname> <given-names>O.</given-names></name> <name><surname>Weller</surname> <given-names>T.</given-names></name> <name><surname>Windeler</surname> <given-names>M.</given-names></name> <name><surname>Lenarz</surname> <given-names>T.</given-names></name> <name><surname>B&#x00FC;chner</surname> <given-names>A.</given-names></name> <etal/></person-group>. (<year>2018</year>). <article-title>Patient specific selection of lateral wall cochlear implant electrodes based on anatomical indication ranges</article-title>. <source>PLoS One</source> <volume>13</volume>:<fpage>e0206435</fpage>. doi: <pub-id pub-id-type="doi">10.1371/journal.pone.0206435</pub-id>, PMID: <pub-id pub-id-type="pmid">30365565</pub-id></citation></ref>
<ref id="ref56"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Von Ilberg</surname> <given-names>C. A.</given-names></name> <name><surname>Baumann</surname> <given-names>U.</given-names></name> <name><surname>Kiefer</surname> <given-names>J.</given-names></name> <name><surname>Tillein</surname> <given-names>J.</given-names></name> <name><surname>Adunka</surname> <given-names>O. F.</given-names></name></person-group> (<year>2011</year>). <article-title>Electric-acoustic stimulation of the auditory system: a review of the first decade</article-title>. <source>Audiol. Neurotol.</source> <volume>16</volume>, <fpage>1</fpage>&#x2013;<lpage>30</lpage>. doi: <pub-id pub-id-type="doi">10.1159/000327765</pub-id>, PMID: <pub-id pub-id-type="pmid">21606646</pub-id></citation></ref>
<ref id="ref57"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Walia</surname> <given-names>A.</given-names></name> <name><surname>Shew</surname> <given-names>M. A.</given-names></name> <name><surname>Lee</surname> <given-names>D. S.</given-names></name> <name><surname>Lefler</surname> <given-names>S. M.</given-names></name> <name><surname>Kallogjeri</surname> <given-names>D.</given-names></name> <name><surname>Wick</surname> <given-names>C. C.</given-names></name></person-group> (<year>2022</year>). <article-title>Promontory Electrocochleography recordings to predict speech-perception performance in Cochlear implant recipients</article-title>. <source>Otol. Neurotol.</source> <volume>43</volume>, <fpage>915</fpage>&#x2013;<lpage>923</lpage>. doi: <pub-id pub-id-type="doi">10.1097/MAO.0000000000003628</pub-id>, PMID: <pub-id pub-id-type="pmid">35861658</pub-id></citation></ref>
<ref id="ref58"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Walia</surname> <given-names>A.</given-names></name> <name><surname>Shew</surname> <given-names>M. A.</given-names></name> <name><surname>Varghese</surname> <given-names>J.</given-names></name> <name><surname>Lefler</surname> <given-names>S. M.</given-names></name> <name><surname>Bhat</surname> <given-names>A.</given-names></name> <name><surname>Ortmann</surname> <given-names>A. J.</given-names></name> <etal/></person-group>. (<year>2024</year>). <article-title>Electrocochleography-based tonotopic map: II. Frequency-to-place mismatch impacts speech-perception outcomes in cochlear implant recipients</article-title>. <source>Ear Hear.</source> <volume>45</volume>, <fpage>1406</fpage>&#x2013;<lpage>1417</lpage>. doi: <pub-id pub-id-type="doi">10.1097/AUD.0000000000001528</pub-id>, PMID: <pub-id pub-id-type="pmid">38880958</pub-id></citation></ref>
<ref id="ref59"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>W&#x00FC;rfel</surname> <given-names>W.</given-names></name> <name><surname>Lanfermann</surname> <given-names>H.</given-names></name> <name><surname>Lenarz</surname> <given-names>T.</given-names></name> <name><surname>Majdani</surname> <given-names>O.</given-names></name></person-group> (<year>2014</year>). <article-title>Cochlear length determination using cone beam computed tomography in a clinical setting</article-title>. <source>Hear. Res.</source> <volume>316</volume>, <fpage>65</fpage>&#x2013;<lpage>72</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.heares.2014.07.013</pub-id>, PMID: <pub-id pub-id-type="pmid">25124151</pub-id></citation></ref>
</ref-list>
</back>
</article>