<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" article-type="review-article" dtd-version="2.3" xml:lang="EN">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Neurosci.</journal-id>
<journal-title>Frontiers in Neuroscience</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Neurosci.</abbrev-journal-title>
<issn pub-type="epub">1662-453X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fnins.2024.1348434</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Neuroscience</subject>
<subj-group>
<subject>Review</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Flexible high-density microelectrode arrays for closed-loop brain&#x2013;machine interfaces: a review</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes"><name><surname>Liu</surname> <given-names>Xiang</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="aff" rid="aff2"><sup>2</sup></xref><xref ref-type="corresp" rid="c001"><sup>&#x002A;</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/2272238/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author"><name><surname>Gong</surname> <given-names>Yan</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref><xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/1155646/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author"><name><surname>Jiang</surname> <given-names>Zebin</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref><xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/2644761/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/data-curation/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author"><name><surname>Stevens</surname> <given-names>Trevor</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/2644845/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/data-curation/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
</contrib>
<contrib contrib-type="author"><name><surname>Li</surname> <given-names>Wen</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="aff" rid="aff2"><sup>2</sup></xref><xref ref-type="aff" rid="aff3"><sup>3</sup></xref><xref ref-type="aff" rid="aff4"><sup>4</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/201815/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/resources/"/>
<role content-type="https://credit.niso.org/contributor-roles/supervision/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
</contrib-group>
<aff id="aff1"><sup>1</sup><institution>Neuroscience Program, Department of Physiology, Michigan State University</institution>, <addr-line>East Lansing, MI</addr-line>, <country>United States</country></aff>
<aff id="aff2"><sup>2</sup><institution>Institute for Quantitative Health Science and Engineering (IQ)</institution>, <addr-line>East Lansing, MI</addr-line>, <country>United States</country></aff>
<aff id="aff3"><sup>3</sup><institution>Department of Electrical and Computer Engineering, Michigan State University</institution>, <addr-line>East Lansing, MI</addr-line>, <country>United States</country></aff>
<aff id="aff4"><sup>4</sup><institution>Department of Biomedical Engineering, Michigan State University</institution>, <addr-line>East Lansing, MI</addr-line>, <country>United States</country></aff>
<author-notes>
<fn fn-type="edited-by" id="fn0001">
<p>Edited by: Serafim Rodrigues, Basque Center for Applied Mathematics, Spain</p>
</fn>
<fn fn-type="edited-by" id="fn0002">
<p>Reviewed by: Fanpeng Kong, Broadcom Inc., United States</p>
<p>Yiming Han, The University of Texas at Austin, United States</p>
</fn>
<corresp id="c001">&#x002A;Correspondence: Xiang Liu, <email>Liuxia76@msu.edu</email></corresp>
</author-notes>
<pub-date pub-type="epub">
<day>15</day>
<month>04</month>
<year>2024</year>
</pub-date>
<pub-date pub-type="collection">
<year>2024</year>
</pub-date>
<volume>18</volume>
<elocation-id>1348434</elocation-id>
<history>
<date date-type="received">
<day>02</day>
<month>12</month>
<year>2023</year>
</date>
<date date-type="accepted">
<day>12</day>
<month>01</month>
<year>2024</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x00A9; 2024 Liu, Gong, Jiang, Stevens and Li.</copyright-statement>
<copyright-year>2024</copyright-year>
<copyright-holder>Liu, Gong, Jiang, Stevens and Li</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<p>Flexible high-density microelectrode arrays (HDMEAs) are emerging as a key component in closed-loop brain&#x2013;machine interfaces (BMIs), providing high-resolution functionality for recording, stimulation, or both. The flexibility of these arrays provides advantages over rigid ones, such as reduced mismatch between interface and tissue, resilience to micromotion, and sustained long-term performance. This review summarizes the recent developments and applications of flexible HDMEAs in closed-loop BMI systems. It delves into the various challenges encountered in the development of ideal flexible HDMEAs for closed-loop BMI systems and highlights the latest methodologies and breakthroughs to address these challenges. These insights could be instrumental in guiding the creation of future generations of flexible HDMEAs, specifically tailored for use in closed-loop BMIs. The review thoroughly explores both the current state and prospects of these advanced arrays, emphasizing their potential in enhancing BMI technology.</p>
</abstract>
<kwd-group>
<kwd>microelectrode array</kwd>
<kwd>closed-loop</kwd>
<kwd>brain-machine interfaces</kwd>
<kwd>flexibility</kwd>
<kwd>high density</kwd>
</kwd-group>
<counts>
<fig-count count="4"/>
<table-count count="1"/>
<equation-count count="0"/>
<ref-count count="144"/>
<page-count count="15"/>
<word-count count="12364"/>
</counts>
<custom-meta-wrap>
<custom-meta>
<meta-name>section-at-acceptance</meta-name>
<meta-value>Neural Technology</meta-value>
</custom-meta>
</custom-meta-wrap>
</article-meta>
</front>
<body>
<sec sec-type="intro" id="sec1">
<label>1</label>
<title>Introduction</title>
<p>Brain-machine interfaces (BMI) have emerged as a powerful tool for understanding the brain (<xref ref-type="bibr" rid="ref39">Janjua et al., 2021</xref>), restoring lost function in individuals with neurological disorders (<xref ref-type="bibr" rid="ref42">Johnson et al., 2016</xref>; <xref ref-type="bibr" rid="ref63">Mohammed et al., 2022</xref>) and enhancing brain functions (<xref ref-type="bibr" rid="ref70">Olsen et al., 2022</xref>). Closed-loop BMIs, in which neural activity is recorded and decoded in real-time to drive external devices or stimulate neural tissue, hold promise for enhancing the accuracy and efficacy of BMI applications (<xref ref-type="bibr" rid="ref106">Tanskanen et al., 2020</xref>). These systems are widely utilized in neurorehabilitation (<xref ref-type="bibr" rid="ref4">Ang et al., 2015</xref>; <xref ref-type="bibr" rid="ref23">Donati et al., 2016</xref>; <xref ref-type="bibr" rid="ref55">Liu and Ushiba, 2022</xref>), prosthetics control (<xref ref-type="bibr" rid="ref3">Ajiboye et al., 2017</xref>), treatment of severe neurological disorders (<xref ref-type="bibr" rid="ref72">Ouyang et al., 2023</xref>), and adaptive deep brain stimulation (<xref ref-type="bibr" rid="ref14">Castrioto and Moro, 2013</xref>; <xref ref-type="bibr" rid="ref54">Little et al., 2016</xref>; <xref ref-type="bibr" rid="ref87">Scholten et al., 2020</xref>), among other fields. Typically, neural signals (e.g., electrical activity of neurons) are initially recorded using a neural interface device, such as a microelectrode array (MEA). These signals are then decoded and processed to derive user intentions, which are translated into commands for controlling an external device. Subsequently, feedback from the device, often in the form of electrical stimulation, is delivered back to the brain, closing the loop (<xref ref-type="bibr" rid="ref129">Zhang et al., 2023</xref>). This contrasts with open-loop systems, which might only read brain signals or stimulate the brain without any real-time feedback (<xref ref-type="bibr" rid="ref106">Tanskanen et al., 2020</xref>).</p>
<p>A MEA consists of a grid of tightly spaced microelectrodes that can be used to detect electrophysiological signals from neurons or to deliver electrical pulses to stimulate neural activity (<xref ref-type="bibr" rid="ref2">Adams et al., 2005</xref>). MEAs are commonly integral to closed-loop BMIs, serving as components that either decode neural signals, deliver electrical stimulation back to the brain, or perform both functions, thus enabling bidirectional communications. Conventional MEAs with single channel or multiple channels separated with far distance(&#x003E;200&#x2009;&#x03BC;m) have historically played a vital role in the development and applications of closed-loop BMIs (<xref ref-type="bibr" rid="ref18">Chou et al., 2011</xref>). However, the high-density microelectrode arrays (HDMEAs), with significantly enhanced density and channel count arranged on a limited area (<xref ref-type="bibr" rid="ref51">Lee et al., 2022</xref>), offer several advantages compared to conventional MEAs. First, HDMEAs can detect and stimulate neural activity with higher spatial resolution and greater precision, enabling more detailed mapping of neural networks and a better understanding of complex brain functions. Second, the high density of electrodes provides a more comprehensive dataset. This richness of data is essential for advanced neural decoding algorithms, which can translate neural activity into more accurate and nuanced commands for BMIs. Third, in lower-density arrays, signals from multiple neurons are often averaged over larger electrode areas, potentially losing critical information. HDMEAs can reduce this spatial averaging, capturing more discrete signals from individual or small groups of neurons. Finally, with more electrodes interacting with neurons, HDMEAs can potentially facilitate more complex and nuanced interactions between the BMI and the brain, leading to more sophisticated applications and therapies.</p>
<p>HDMEAs can be categorized into rigid and flexible types, depending on the material of the substrate used for fabricating the microelectrodes (<xref ref-type="bibr" rid="ref107">Tanwar et al., 2022</xref>). At present, the most advanced HDMEAs are rigid leveraging the state-of-the-art silicon manufacturing technology. For example, Neuropixels 2.0, a miniaturized high-density silicone-based probe, has total of 1,280 channels on one shank with a profile of 10&#x2009;mm &#x00D7; 70&#x2009;&#x03BC;m &#x00D7; 24&#x2009;&#x03BC;m (<xref ref-type="bibr" rid="ref100">Steinmetz et al., 2021</xref>). However, rigid HDMEAs often encounter limitations (<xref ref-type="bibr" rid="ref42">Johnson et al., 2016</xref>; <xref ref-type="bibr" rid="ref48">Kolaya and Firestein, 2021</xref>; <xref ref-type="bibr" rid="ref69">Oldroyd and Malliaras, 2022</xref>), including inflammatory response, tissue damage, limited long-term stability, and biocompatibility issues.</p>
<p>Flexible MEAs, often fabricated from soft materials like polyimide or parylene, can adeptly mold to the neural tissue and provide less mismatch between interfaces and brain tissue, reducing the risk of tissue damage and ensuring a more stable, intimate interaction with neurons (<xref ref-type="bibr" rid="ref5">Araki et al., 2020</xref>). Furthermore, the adaptability of flexible MEAs allows them to accommodate physiological changes and movements within the brain, maintaining consistent interfacing and thereby supporting the longevity and robustness of the BMI system (<xref ref-type="bibr" rid="ref90">Sharafkhani et al., 2022</xref>; <xref ref-type="bibr" rid="ref119">Xu et al., 2022</xref>). Consequently, flexibility in MEAs is not merely a beneficial attribute but a quintessential one, ensuring the viability, reliability, and efficacy of closed-loop BMIs in both research and clinical applications. Further merging the benefits of both, flexible HDMEAs bring the adaptability of flexible substrates to high-resolution electrode arrays, proving invaluable for discerning intricate neuronal dynamics, especially in dynamic or soft tissue environments where precision and conformability are paramount (<xref ref-type="bibr" rid="ref133">Zhou et al., 2023</xref>).</p>
<p>Apart from flexibility and high density, the ideal profile of flexible HDMEAs for closed-loop BMIs comprises several crucial attributes. These include biocompatibility (<xref ref-type="bibr" rid="ref92">Shepherd et al., 2021</xref>), high-quality performance (<xref ref-type="bibr" rid="ref66">Nam, 2021</xref>), and long-term stability (<xref ref-type="bibr" rid="ref115">Ward et al., 2009</xref>; <xref ref-type="bibr" rid="ref31">Golabchi et al., 2019</xref>), etc. However, the development of flexible HDMEAs with these ideal properties entails confronting both the general challenges inherent to HDMEAs and specific challenges unique to their flexible design, encompassing mechanical (<xref ref-type="bibr" rid="ref69">Oldroyd and Malliaras, 2022</xref>), electrical (<xref ref-type="bibr" rid="ref105">Szostak et al., 2017</xref>; <xref ref-type="bibr" rid="ref80">Qiang et al., 2021</xref>), biological (<xref ref-type="bibr" rid="ref31">Golabchi et al., 2019</xref>), chemical (<xref ref-type="bibr" rid="ref92">Shepherd et al., 2021</xref>), and interconnection issues (<xref ref-type="bibr" rid="ref8">Behfar et al., 2021</xref>). In response, researchers employ strategies spanning material exploration (<xref ref-type="bibr" rid="ref10">Bonafe, 2022</xref>; <xref ref-type="bibr" rid="ref15">Chik et al., 2022</xref>), flexible HDMEA design innovation, advanced fabrication strategies (<xref ref-type="bibr" rid="ref87">Scholten et al., 2020</xref>; <xref ref-type="bibr" rid="ref89">Shah et al., 2022</xref>; <xref ref-type="bibr" rid="ref118">Xiang et al., 2022</xref>), engineering optimization (<xref ref-type="bibr" rid="ref15">Chik et al., 2022</xref>; <xref ref-type="bibr" rid="ref120">Yan et al., 2022</xref>; <xref ref-type="bibr" rid="ref124">Yin et al., 2022</xref>), and holistic combination strategies (<xref ref-type="bibr" rid="ref27">Eunah et al., 2022</xref>; <xref ref-type="bibr" rid="ref36">Hong et al., 2022</xref>), aiming to enhance performance and minimize risks in flexible neural interfacing devices.</p>
<p>The aim of this review is to provide a comprehensive examination of flexible HDMEAs within the realm of closed-loop BMIs. It offers a detailed analysis of what constitutes high-density configuration, the core principles of HDMEA design and fabrication, alongside showcasing the latest exemplars in the field. The review critically identifies and discusses the spectrum of challenges that are currently faced including mechanical, electrical, chemical, biological, and those related to high-density interconnections. Subsequently, it discusses innovative strategies and recent advancements in materials, design, surface modifications, and fabrication that are paving the way for the next generation of flexible HDMEAs. The ultimate goal is to elucidate the trajectory of flexible HDMEAs&#x2019; evolution, framing the current state while projecting into the future implications for closed-loop BMIs.</p>
</sec>
<sec id="sec2">
<label>2</label>
<title>Flexible HDMEAs in closed-loop BMIs</title>
<sec id="sec3">
<label>2.1</label>
<title>Definition of high density</title>
<p>For a long time, we lacked a clear definition of HDMEAs. Among the published studies, MEAs that labeled high density have electrode densities ranging from less than one channel per square millimeter to thousands of channels per square millimeter. The variability in HDMEA definitions can be attributed to application-specific density requirements&#x2014;high for brain neural spaces under 100&#x2009;&#x03BC;m and lower for muscular targets over several thousand square microns (<xref ref-type="bibr" rid="ref116">Wiedemann and McDaid, 2017</xref>; <xref ref-type="bibr" rid="ref16">Choi et al., 2020</xref>)&#x2014;and the diversity in materials and technologies, which results in differing channel densities, ranging from a few to thousands of channels per square millimeter. In a recent paper, the high density was defined as the spacing among electrode sites being no more than 100&#x2009;&#x03BC;m (<xref ref-type="bibr" rid="ref114">Wang et al., 2023</xref>). Considering our discussion on flexible HDMEAs is focused on BMIs that targets neurons in brain tissue in this article, we mainly select flexible HDMEAs that have a pitch within 200&#x2009;&#x03BC;m.</p>
</sec>
<sec id="sec4">
<label>2.2</label>
<title>Design and fabrication principles of flexible HDMEAs</title>
<p>The fabrication of flexible HDMEAs requires a comprehensive strategy that seamlessly integrates device geometries, material selection, fabrication techniques and approaches, surface modification and packaging methods, etc. Key considerations in fabrication of flexible HDMEAs are discussed below.</p>
<list list-type="order">
<list-item>
<p>Device geometries of a HDMEA encompass the spatial and physical configurations, including the arrangement, shape, size, and spacing of the electrodes, along with the overall structure of the device. This involves the meticulous layout of electrodes, which can vary in shape and size, and are strategically spaced to capture localized neural activity effectively. The shape and spatial configuration of HDMEAs are crucial for neural interfacing, with designs ranging from flat, planar structures (<xref ref-type="bibr" rid="ref128">Zeng et al., 2022</xref>) to complex, curved (<xref ref-type="bibr" rid="ref40">Ji et al., 2020a</xref>), or three-dimensional (3D) forms (<xref ref-type="bibr" rid="ref50">Le Floch et al., 2022</xref>; <xref ref-type="bibr" rid="ref12">Brown et al., 2023</xref>; <xref ref-type="bibr" rid="ref58">McDonald et al., 2023</xref>) tailored to specific anatomical contexts, such as the cortical surface or deep brain regions. The overall shape impacts the HDMEA&#x2019;s ability to establish a stable interface with neural tissues, its mechanical stability, and its long-term biocompatibility, while the arrangement of electrodes&#x2014;potentially organized in grids (<xref ref-type="bibr" rid="ref73">Park et al., 2018</xref>; <xref ref-type="fig" rid="fig1">Figure 1B</xref>), linear arrays (<xref ref-type="bibr" rid="ref64">Musk, 2019</xref>; <xref ref-type="bibr" rid="ref133">Zhou et al., 2023</xref>; <xref ref-type="fig" rid="fig2">Figures 2B</xref>,<xref ref-type="fig" rid="fig2">C</xref>, <xref ref-type="fig" rid="fig4">4A</xref>)&#x2014;and their individual shapes and sizes are meticulously crafted to enhance signal acquisition and stimulation capabilities.</p>
</list-item>
<list-item>
<p>The selection of electrode materials, encompassing not only the substrate but also the conductive elements, insulating materials, and materials utilized in other components, holds critical importance in the development of flexible HDMEAs. For substrates in neural interfaces, the most commonly used materials encompass polymers, such as polyimide (<xref ref-type="bibr" rid="ref85">Schander et al., 2021</xref>; <xref ref-type="bibr" rid="ref101">Steins et al., 2022</xref>), polydimethylsiloxane (PDMS) (<xref ref-type="bibr" rid="ref86">Schiavone et al., 2020</xref>; <xref ref-type="bibr" rid="ref17">Chong, 2022</xref>), parylene C (<xref ref-type="bibr" rid="ref32">Golda-Cepa et al., 2020</xref>; <xref ref-type="bibr" rid="ref113">Wang et al., 2020</xref>), as well as other materials such as silk (<xref ref-type="bibr" rid="ref19">Cointe et al., 2022</xref>), medical adhesive tape (<xref ref-type="bibr" rid="ref22">David-Pur et al., 2014</xref>), hydrogels (<xref ref-type="bibr" rid="ref127">Zeng and Wu, 2022</xref>), predominantly chosen for their biocompatibility, flexibility, and electrical insulation, ensuring safe and stable interfacing with neural tissues. An ideal electrode material needs to meet at least the following requirements: (1) compatible with cell/tissue without causing any changes in physiology and viability, (2) have good conductivity and low impedance to ensure a high signal-to-noise ratio (SNR), (3) have stable mechanical, physical, and chemical properties in the physiological environment (<xref ref-type="bibr" rid="ref134">Zhu et al., 2021</xref>). The selection of substrate materials is usually based on the properties such as electrical insulation, biocompatibility, durability, transmittance, etc. The most widely used electrode materials are inert metals, such as gold (Au), platinum (Pt), platinum black, iridium (Ir), and iridium oxide (IrOx), renowned for their high conductivity and biocompatibility, but many promising new materials have been developed for various needs in recent years.</p>
</list-item>
<list-item>
<p>The development of flexible HDMEAs also necessitates careful consideration of fabrication methods, surface modification techniques, and packaging strategies to ensure optimal performance and durability in neural interfacing applications. Fabrication methods for Flexible HDMEAs intertwine various techniques to construct devices tailored to specific neural interfacing applications, with conventional MEAs often leveraging photolithography, etching, and physical vapor deposition to meticulously pattern and construct electrodes on typically rigid substrates like silicon. Surface modification of flexible HDMEA includes changes in surface chemicals and morphology, which can not only affect the surface area and change the impedance to improve SNR (<xref ref-type="bibr" rid="ref105">Szostak et al., 2017</xref>; <xref ref-type="bibr" rid="ref68">Niederhoffer et al., 2023</xref>), but also facilitate cellular adhesion of neurons to the surface of flexible HDMEAs (<xref ref-type="bibr" rid="ref12">Brown et al., 2023</xref>). Besides, packaging strategies are crucial to the reliability and lifetime of flexible HDMEA (<xref ref-type="bibr" rid="ref46">Kim et al., 2012</xref>; <xref ref-type="bibr" rid="ref88">Seok, 2021</xref>; <xref ref-type="bibr" rid="ref91">Shen and Maharbiz, 2021</xref>). Suitable packaging should ensure the hermeticity for HDMEAs, to protect the inner parts of the HDMEAs from the physical environment, and to protect the host from any injury caused by chemical leakage or electrical leakage (<xref ref-type="bibr" rid="ref88">Seok, 2021</xref>; <xref ref-type="bibr" rid="ref122">Yang et al., 2021a</xref>,<xref ref-type="bibr" rid="ref123">b</xref>).</p>
</list-item>
</list>
<fig position="float" id="fig1">
<label>Figure 1</label>
<caption>
<p>Flexible HDMEAs integrated with different stimulation modules. <bold>(A)</bold> Flexible HDMEAs probe with electrical stimulus and neuronal firings detection. (I) The image of the neural probe&#x2019;s shank and the pattern of the microelectrodes. (II) The fully fabricated probe connected to a customized PCB connector. Reproduced from <xref ref-type="bibr" rid="ref15">Chik et al. (2022)</xref> with permission from 2022 Wiley-VCH. <bold>(B)</bold> Flexible graphene MEA with electrical stimulation for epilepsy. (I) Schematic of a graphene-based seizure sensor. (II) Optical images of an epilepsy treatment sensor on a tube. (III) Photograph of a 30-electrode transparent array on the mouse brain. Reproduced from <xref ref-type="bibr" rid="ref73">Park et al. (2018)</xref> with permission from 2018 WILEY-VCH. <bold>(C)</bold> Microfluidic perforated MEAs with the capability of locally delivering chemical stimulation. Reproduced from <xref ref-type="bibr" rid="ref26">Esteban-Linares et al. (2023)</xref> with permission from 2023 The Royal Society of Chemistry. <bold>(D)</bold> Flexible electronics generating optical and electrical stimulation in multi-Encephalic Regions. (I) The exploded view of a single flexible channel that contains a &#x03BC;-LED, four microelectrodes, and three ion-selective sensors. (II) An image of a wireless circuit connected with four channels that have been inserted into a PDMS chamber. (III) Images of the top and bottom sides of an implanted channel. Reproduced from <xref ref-type="bibr" rid="ref53">Ling et al. (2020)</xref> with permission from 2020 WILEY-VCH.</p>
</caption>
<graphic xlink:href="fnins-18-1348434-g001.tif"/>
</fig>
<fig position="float" id="fig2">
<label>Figure 2</label>
<caption>
<p>Representative flexible HDMEAs in various configurations for use in closed loop. (A) Multi flexible electrode &#x201C;threads&#x201D; with as many as 3072 electrodes per array distributed across 96 threads. (I) A packaged sensor device. (II) Image of individual electrodes for the thread design in panel I. (III) &#x201C;Linear Edge&#x201D; probes, with 32 electrode contacts spaced by 50&#x2009;&#x03BC;m. (IV) &#x201C;Tree&#x201D; probes with 32 electrode contacts spaced by 75&#x2009;&#x03BC;m. Reproduced from <xref ref-type="bibr" rid="ref64">Musk (2019)</xref>, licensed under CC BY-ND 4.0. (B) Schematic of optically transparent surface arrays with an insertion probe(I) and the micrograph(II). Reproduced from <xref ref-type="bibr" rid="ref111">Uguz and Shepard (2022)</xref>, licensed under CC BY NC 4.0. (C) A scalable silicon microneedle array (SiMNA) on thin, transparent, and flexible substrates. (I) A schematic of a 32-channel SiMNA on flex with polyimide passivating the metal leads and parylene-C passivating the SiMNA (excluding the tips). Inset on the left shows magnified view of the exposed SiMN tip with PtNM coated on Si, and the inset on the right shows the scanning electron microscopy (SEM) image of the PtNM surface at the tip. (II) A magnified optical image of 32-channel SiMNA with 50&#x2009;&#x03BC;m needle-to-needle spacing. The inset shows the magnified photograph taken from the side of the SiMNA. (III) A photograph of the device mounted on 3D-printed custom headpost. Reproduced from <xref ref-type="bibr" rid="ref51">Lee et al. (2022)</xref> with permission from 2022 Wiley-VCH. (D) Neural probes with adaptive bending stiffness determined by the hydration states of the hydrogel matrix. Rproduced from <xref ref-type="bibr" rid="ref75">Park et al. (2021)</xref> with permission from 2022 The Authors.</p>
</caption>
<graphic xlink:href="fnins-18-1348434-g002.tif"/>
</fig>
<fig position="float" id="fig3">
<label>Figure 3</label>
<caption>
<p>Strategies for future flexible HDMEAs. (A) Multifunctional biomimetic neural probe system, with multichannel flexible electrode array and high sensitivity sensor array. Adapted from <xref ref-type="bibr" rid="ref133">Zhou et al. (2023)</xref>, licensed under CC BY 4.0. (B) PPy/SWCNTs-modification on microelectrodes for electrical stimulation and detection. Reprinted with permission from <xref ref-type="bibr" rid="ref121">Yang et al. (2023)</xref>. Copyright 2023 American Chemical Society. (C) 3D-printed arrays for neural recording. Adapted with permission from <xref ref-type="bibr" rid="ref12">Brown et al. (2023)</xref>, licensed under CC BY 4.0. (D) A periodic arrangement of stretchable ACF (S-ACF) incorporated within a thermoplastic block copolymer film. (I) Scheme for the fabrication of the S-ACF. (II) Left: Cross-sectional SEM image taken after the particle assembly in the template. Right: Cross-sectional SEM image of the S-ACF after the hot pressing. (III) Optical images of the S-ACF when stretched (&#x03B5;&#x2009;=&#x2009;100%) and strain released (&#x03B5;&#x2009;=&#x2009;0%). Adapted with permission from <xref ref-type="bibr" rid="ref37">Hwang et al. (2021)</xref>, licensed under CC BY 4.0.</p>
</caption>
<graphic xlink:href="fnins-18-1348434-g003.tif"/>
</fig>
<fig position="float" id="fig4">
<label>Figure 4</label>
<caption>
<p>Examples of advanced materials for future flexible HDMEAs. (A) Silk-Optrode comprising a silk protein optical fiber substrate and multiple flexible HDMEAs. (I) A schematic of a silk optical fiber-based Silk-Optrode probe and the multilayer structure of the device. (II) A schematic of the probe implanted into brain tissue, comparing with the rigid probe and the flexible silk optical fiber. (III) The strain&#x2013;stress curve of the silk optical fiber in the hydrated and dehydrated states. Inset, typical hydrated silk optical fiber before and after stretching. Reproduced from <xref ref-type="bibr" rid="ref132">Zhou et al. (2022)</xref>, licensed under CC BY 4.0. (B) Highly conducting and stretchable double-network hydrogel. (I) Schematic of PEDOT:PSS/PVA double network(DN) hydrogel. (II) PEDOT:PSS/PVA hydrogel under stretching, twisting, and twisted stretching. (III) Electrical conductivity of the as-made hydrogel and the PEDOT:PSS/PVA DN hydrogel with acid treatment and conductivity of the PEDOT:PSS/PVA DN hydrogel for 3 months. Reproduced from <xref ref-type="bibr" rid="ref52">Li et al. (2022)</xref> with permission from 2022 Wiley-VCH. (C) A new structure of transparent and flexible MEA, with ultrathin gold nanofilm with polyelectrolyte multilayers (PEM) as the metallic film nucleation-inducing seed layer (NISL). (I) Schematic diagrams of the formation of ultrathin gold electrodes on polyelectrolyte coatings. (II) SEM images of 8 nm-thick gold electrodes deposited on a bare silicon substrate (left) and a (PEI/PSS)5 NISL coated on silicon (right). Reproduced from <xref ref-type="bibr" rid="ref36">Hong et al. (2022)</xref> adapted with permission from 2021 Wiley-VCH.</p>
</caption>
<graphic xlink:href="fnins-18-1348434-g004.tif"/>
</fig>
</sec>
<sec id="sec5">
<label>2.3</label>
<title>Examples of state-of-the-art flexible HDMEAs for closed-loop BMI</title>
<p>This section highlights the latest advancements in flexible HDMEAs for closed loop BMIs over the past five years. The summary of the most recent flexible HDMEAs integrated in closed-loop BMIs is shown in <xref ref-type="table" rid="tab1">Table 1</xref>.</p>
<table-wrap position="float" id="tab1">
<label>Table 1</label>
<caption>
<p>Summary of the most recent flexible HDMEAs integrated in closed loop BMIs.</p>
</caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th align="left" valign="middle">References</th>
<th align="center" valign="middle">Electrodes numbers</th>
<th align="center" valign="middle">Electrode size</th>
<th align="center" valign="middle">Center to center distance</th>
<th align="center" valign="middle">Electrode materials</th>
<th align="center" valign="middle">Packaging materials</th>
<th align="center" valign="middle">Lifetime being tested</th>
</tr>
</thead>
<tbody>
<tr>
<td align="left" valign="middle">
<xref ref-type="bibr" rid="ref2002">Guo et al. (2021)</xref>
</td>
<td align="center" valign="middle">16</td>
<td align="center" valign="middle">Dia&#x2009;=&#x2009;20&#x2009;&#x03BC;m, 25&#x2009;&#x03BC;m, 30&#x2009;&#x03BC;m</td>
<td align="center" valign="middle">150&#x2009;&#x03BC;m</td>
<td align="center" valign="middle">Cr, Au</td>
<td align="center" valign="middle">Parylene</td>
<td align="center" valign="middle">28&#x2009;days</td>
</tr>
<tr>
<td align="left" valign="middle">
<xref ref-type="bibr" rid="ref2003">Vajrala et al. (2023)</xref>
</td>
<td align="center" valign="middle">4</td>
<td align="center" valign="middle">Dia&#x2009;=&#x2009;40&#x2009;&#x03BC;m, 100&#x2009;&#x03BC;m</td>
<td align="center" valign="middle">100 &#x03BC;m&#x002A;</td>
<td align="center" valign="middle">Ti, Au</td>
<td align="center" valign="middle">Parylene</td>
<td align="center" valign="middle">8&#x2009;weeks</td>
</tr>
<tr>
<td align="left" valign="middle">
<xref ref-type="bibr" rid="ref2004">Kauth et al. (2024)</xref>
</td>
<td align="center" valign="middle">30</td>
<td align="center" valign="middle">1,910&#x2009;&#x03BC;m<sup>2</sup></td>
<td align="center" valign="middle">50.9&#x2009;&#x03BC;m</td>
<td align="center" valign="middle">Ti, Au</td>
<td align="center" valign="middle">Polyimide</td>
<td align="center" valign="middle">24&#x2009;h</td>
</tr>
<tr>
<td align="left" valign="middle">
<xref ref-type="bibr" rid="ref133">Zhou et al. (2023)</xref>
</td>
<td align="center" valign="middle">128</td>
<td align="center" valign="middle">N/A</td>
<td align="center" valign="middle">N/A</td>
<td align="center" valign="middle">Au</td>
<td align="center" valign="middle">Polyimide</td>
<td align="center" valign="middle">16&#x2009;weeks</td>
</tr>
<tr>
<td align="left" valign="middle">
<xref ref-type="bibr" rid="ref15">Chik et al. (2022)</xref>
</td>
<td align="center" valign="middle">8</td>
<td align="center" valign="middle">20&#x2009;&#x00D7;&#x2009;40&#x2009;&#x03BC;m</td>
<td align="center" valign="middle">50&#x2009;&#x03BC;m</td>
<td align="center" valign="middle">Au</td>
<td align="center" valign="middle">Parylene</td>
<td align="center" valign="middle">5&#x2009;weeks</td>
</tr>
<tr>
<td align="left" valign="middle">
<xref ref-type="bibr" rid="ref2005">Max et al.(2022)</xref>
</td>
<td align="center" valign="middle">60</td>
<td align="center" valign="middle">Dia&#x2009;=&#x2009;10&#x2009;&#x03BC;m, 22&#x2009;&#x03BC;m, 50&#x2009;&#x03BC;m, 150&#x2009;&#x03BC;m, 582&#x2009;&#x03BC;m, 1,000&#x2009;&#x03BC;m</td>
<td align="center" valign="middle">200&#x2009;&#x03BC;m</td>
<td align="center" valign="middle">Indium tin oxide</td>
<td align="center" valign="middle">Polyimide</td>
<td align="center" valign="middle">N/A</td>
</tr>
<tr>
<td align="left" valign="middle">
<xref ref-type="bibr" rid="ref114">Wang et al. (2023)</xref>
</td>
<td align="center" valign="middle">8</td>
<td align="center" valign="middle">Dia =25&#x2009;&#x03BC;m</td>
<td align="center" valign="middle">70&#x2009;&#x03BC;m</td>
<td align="center" valign="middle">Cr, Au</td>
<td align="center" valign="middle">Polyimide</td>
<td align="center" valign="middle">N/A</td>
</tr>
<tr>
<td align="left" valign="middle">
<xref ref-type="bibr" rid="ref2006">Zachariah et al. (2021)</xref>
</td>
<td align="center" valign="middle">60</td>
<td align="center" valign="middle">100&#x2009;&#x03BC;m<sup>2</sup></td>
<td align="center" valign="middle">40&#x2009;&#x03BC;m</td>
<td align="center" valign="middle">Platinum</td>
<td align="center" valign="middle">Polyimide</td>
<td align="center" valign="middle">6&#x2009;weeks</td>
</tr>
<tr>
<td align="left" valign="middle">
<xref ref-type="bibr" rid="ref53">Ling et al. (2020)</xref>
</td>
<td align="center" valign="middle">16</td>
<td align="center" valign="middle">Dia&#x2009;=&#x2009;30&#x2009;&#x03BC;m&#x002A;</td>
<td align="center" valign="middle">100 &#x03BC;m&#x002A;</td>
<td align="center" valign="middle">Au</td>
<td align="center" valign="middle">Polyimide</td>
<td align="center" valign="middle">2&#x2009;weeks</td>
</tr>
<tr>
<td align="left" valign="middle">
<xref ref-type="bibr" rid="ref2009">Silveira et al. (2020)</xref>
</td>
<td align="center" valign="middle">24</td>
<td align="center" valign="middle">25&#x2009;&#x03BC;m&#x2009;&#x00D7;&#x2009;50/70&#x2009;&#x03BC;m</td>
<td align="center" valign="middle">50/70&#x2009;&#x03BC;m</td>
<td align="center" valign="middle">Ti</td>
<td align="center" valign="middle">Parylene</td>
<td align="center" valign="middle">N/A</td>
</tr>
<tr>
<td align="left" valign="middle">
<xref ref-type="bibr" rid="ref2002">Guo et al. (2021)</xref>
</td>
<td align="center" valign="middle">8</td>
<td align="center" valign="middle">Dia&#x2009;=&#x2009;25&#x2009;&#x03BC;m</td>
<td align="center" valign="middle">70&#x2009;&#x03BC;m</td>
<td align="center" valign="middle">Cr/Au</td>
<td align="center" valign="middle">Polyimide</td>
<td align="center" valign="middle">N/A</td>
</tr>
<tr>
<td align="left" valign="middle">
<xref ref-type="bibr" rid="ref2010">Yu et al. (2021)</xref>
</td>
<td align="center" valign="middle">32</td>
<td align="center" valign="middle">30&#x2009;&#x03BC;m&#x2009;&#x00D7;&#x2009;30&#x2009;&#x03BC;m</td>
<td align="center" valign="middle">200&#x2009;&#x03BC;m&#x002A;</td>
<td align="center" valign="middle">Cu</td>
<td align="center" valign="middle">Polyimide</td>
<td align="center" valign="middle">N/A</td>
</tr>
<tr>
<td align="left" valign="middle">
<xref ref-type="bibr" rid="ref114">Wang et al. (2023)</xref>
</td>
<td align="center" valign="middle">8</td>
<td align="center" valign="middle">Dia&#x2009;=&#x2009;25&#x2009;&#x03BC;m</td>
<td align="center" valign="middle">70&#x2009;&#x03BC;m</td>
<td align="center" valign="middle">Cr/Au</td>
<td align="center" valign="middle">Polyimide</td>
<td align="center" valign="middle">N/A</td>
</tr>
<tr>
<td align="left" valign="middle">
<xref ref-type="bibr" rid="ref111">Uguz and Shepard (2022)</xref>
</td>
<td align="center" valign="middle">60</td>
<td align="center" valign="middle">Dia&#x2009;=&#x2009;15&#x2009;&#x03BC;m</td>
<td align="center" valign="middle">40&#x2009;&#x03BC;m</td>
<td align="center" valign="middle">PEDOT:PSS</td>
<td align="center" valign="middle">Parylene</td>
<td align="center" valign="middle">20&#x2009;days</td>
</tr>
<tr>
<td align="left" valign="middle">
<xref ref-type="bibr" rid="ref2007">Seo et al. (2020)</xref>
</td>
<td align="center" valign="middle">20</td>
<td align="center" valign="middle">Dia&#x2009;=&#x2009;150 um</td>
<td align="center" valign="middle">350&#x2009;&#x03BC;m</td>
<td align="center" valign="middle">Ti, Au</td>
<td align="center" valign="middle">PDMS, Parylene-C</td>
<td align="center" valign="middle">N/A</td>
</tr>
<tr>
<td align="left" valign="middle">
<xref ref-type="bibr" rid="ref26">Esteban-Linares et al. (2023)</xref>
</td>
<td align="center" valign="middle">16</td>
<td align="center" valign="middle">30&#x2009;&#x00D7;&#x2009;30 and 40&#x2009;&#x00D7;&#x2009;40&#x2009;&#x03BC;m<sup>2</sup> for graphene, and 60&#x2009;&#x00D7;&#x2009;60 and 80&#x2009;&#x00D7;&#x2009;80&#x2009;&#x03BC;m<sup>2</sup> for Au</td>
<td align="center" valign="middle">200&#x2009;&#x03BC;m</td>
<td align="center" valign="middle">Graphene or Ti/Au</td>
<td align="center" valign="middle">Polyimide on PDMS</td>
<td align="center" valign="middle">N/A</td>
</tr>
<tr>
<td align="left" valign="middle"><xref ref-type="bibr" rid="ref122">Yang et al. (2021a</xref>,<xref ref-type="bibr" rid="ref123">b)</xref></td>
<td align="center" valign="middle">128</td>
<td align="center" valign="middle">Dia&#x2009;=&#x2009;30&#x2009;&#x03BC;m</td>
<td align="center" valign="middle">50&#x2009;&#x03BC;m</td>
<td align="center" valign="middle">PEDOT:PSS</td>
<td align="center" valign="middle">Parylene C</td>
<td align="center" valign="middle">N/A</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn>
<label>&#x002A;</label>
<p>The value comes from an estimate of the pictures provided in the original articles.</p>
</fn>
</table-wrap-foot>
</table-wrap>
<p>Neuralink introduced a scalable high-bandwidth BMI system. This system includes arrays of 96 flexible polymer threads, each with 32 electrodes, yielding a total of 3,072 electrodes (<xref ref-type="bibr" rid="ref64">Musk, 2019</xref>; Shown in <xref ref-type="fig" rid="fig2">Figure 2A</xref>). The electrodes are made of gold and treated with surface modifications by using the electrically conductive polymer poly-ethylenedioxythiophene doped with polystyrene sulfonate (PEDOT: PSS) and IrOx, in order to lower the impedance for electrophysiology and increase the effective charge-carrying capacity of the interface. The electrode array is packaged with polyimide into a compact implantable device with custom chips for low-power amplification and digitization. The entire package for 3,072 channels is less than 23&#x2009;&#x00D7;&#x2009;18.5&#x2009;&#x00D7;&#x2009;2&#x2009;mm<sup>3</sup>. The thin-film HDMEAs provide superior brain tissue compatibility and precise, robot-assisted placement for targeted brain mapping. Their compact design integrates a high-channel-count application specific integrated circuit (ASIC), optimizing size and power efficiency.</p>
<p><xref ref-type="bibr" rid="ref111">Uguz and Shepard (2022)</xref> presented a high-density, mechanically flexible subdural surface microelectrode array for spatially controlled, bipolar, cortical stimulation (Shown in <xref ref-type="fig" rid="fig2">Figure 2B</xref>). The electrodes are made of gold, coated with PEDOT: PSS, and packaged by an ultrathin film (4&#x2009;&#x03BC;m) parylene. These electrodes have a diameter of 15&#x2009;&#x03BC;m and pitch of 40&#x2009;&#x03BC;m. with high-capacitance (&#x003E;1&#x2009;nF) and single neuronal resolution, the electrodes can be programmed to shape the charge injection front selectively at depths approaching 300&#x2009;&#x03BC;m with a lateral resolution better than 100&#x2009;&#x03BC;m. To combine surface stimulation with electrical depth recording, the flexible HDMEA incorporates an implantable shank on the same substrate. The shank extension has 10 electrodes reaching down to 500&#x2009;&#x03BC;m below the pial surface.</p>
<p><xref ref-type="bibr" rid="ref133">Zhou et al. (2023)</xref> developed a neuro-probe system, mimicking mosquito mouthparts, with four shanks, each housing 32-channel electrodes, totaling 128 channels (<xref ref-type="fig" rid="fig3">Figure 3A</xref>). Polyimide was used as its insulation layer, and metal stack of 5&#x2009;nm chromium/150&#x2009;nm nickel/50&#x2009;nm gold was used as conductive layer. The flexible HDMEAs are 2.5&#x2009;&#x03BC;m thick and 105&#x2009;&#x03BC;m wide. The electrodes measure 25&#x2009;&#x00D7;&#x2009;15&#x2009;&#x03BC;m<sup>2</sup> in size and are spaced 70&#x2009;&#x03BC;m apart. These arrays were mounted on a sharpen tungsten wire to facilitate the insertion process. Each of the shanks could be inserted into the brain independently to target different regions. The system also has sensitive sensors to monitor insertion pressure without visual aid. It offers early warning detection for delicate intracranial tissues like vessels, minimizing the risk of damage during implantation. The system demonstrates outstanding postoperative performance, with a unit yield of up to 57% recorded 12&#x2009;h after surgery, and 77% of unit activities being tracked from 4 to 12&#x2009;weeks.</p>
</sec>
</sec>
<sec id="sec6">
<label>3</label>
<title>Challenges in developing and applying flexible HDMEAs in closed-loop BMIs</title>
<p>Although the aforementioned state-of-the-art flexible HDMEAs have advanced the field in various aspects, the development of an ideal flexible HDMEA still requires further improvements. For instance, in terms of density, Neuralink has increased the electrode count to 3,092 through multiple threads (<xref ref-type="bibr" rid="ref64">Musk, 2019</xref>), yet the density per thread still significantly lags behind the most advanced rigid-based HDMEAs. Moreover, the insertion of flexible electrodes remains a significant challenge. Although robots (<xref ref-type="bibr" rid="ref64">Musk, 2019</xref>) and specially designed insertion tools like mosquito mimic needles (<xref ref-type="bibr" rid="ref133">Zhou et al., 2023</xref>) can enhance insertion precision and reduce damage, these auxiliary methods, despite their improvements, cannot completely eliminate the direct brain tissue damage caused by the insertion assistants. Additionally, implants designed for human brain applications are expected to be reliable over long periods, potentially spanning years, but research into their long-term stability is not yet exhaustive. In essence, the development of flexible HDMEAs encounters several common challenges, and the creation of an ideal flexible HDMEA involves addressing both the general challenges inherent to HDMEAs and specific challenges unique to their flexible design. These challenges encompass mechanical, electrical, biological, chemical, and interconnection issues, among others, which will be thoroughly discussed in the following text.</p>
<sec id="sec7">
<label>3.1</label>
<title>Mechanical challenges</title>
<p>Except the general mechanical failures for MEAs, flexible HDMEAs present unique mechanical challenges rooted in their respective material and structural properties. The main failures of flexible HDMEAs in mechanical aspect could be classified into three types: (1) intrinsic failure of stable function, (2) insertion failure, and (3) failure to long time use in physiological environments.</p>
<p>The intrinsic failure of stability function emerges from the very nature of the flexible HDMEA, regardless of its operational environment. Typical problems include physical fracture or cracking of the electrodes, damage to the metal layer via corrosion, delamination due to poor adhesion between layers, the failure of the insulation layer led by pinholes or water penetration (<xref ref-type="bibr" rid="ref69">Oldroyd and Malliaras, 2022</xref>), thereby preventing the development of flexible HDMEAs.</p>
<p>The insertion of flexible HDMEAs into biological tissues introduces a substantial challenge (<xref ref-type="bibr" rid="ref87">Scholten et al., 2020</xref>); maintaining vital flexibility, and/or minimizing cross-sectional dimensions might undermine stiffness, potentially jeopardizing the requisite rigidity for accurate insertion and inadvertently causing microelectrode buckling, tissue damage, or electrode misplacement (<xref ref-type="bibr" rid="ref90">Sharafkhani et al., 2022</xref>). The challenge arises if the stiffness of flexible devices is insufficient for neural tissue penetration, which often resulting in a more complex and less preferable insertion procedure (<xref ref-type="bibr" rid="ref94">Shi et al., 2020</xref>; <xref ref-type="bibr" rid="ref119">Xu et al., 2022</xref>).</p>
<p>The harsh biological setting where electrodes are placed can compromise their mechanical stability, especially long-term post-implantation (<xref ref-type="bibr" rid="ref69">Oldroyd and Malliaras, 2022</xref>; <xref ref-type="bibr" rid="ref81">Ramesh et al., 2022</xref>). This environment can induce electrode fracture, corrosion, delamination, swelling, dissolution, and mechanical stress, notably in the presence of continuous electrical stimulation (<xref ref-type="bibr" rid="ref69">Oldroyd and Malliaras, 2022</xref>).</p>
</sec>
<sec id="sec8">
<label>3.2</label>
<title>Electrical challenges</title>
<p>Developing HDMEAs suffers from high initial impedance because of the small-feature geometry, so that smaller electrodes are inherently noisier, exhibit worse recording quality, and are less functional because of decreased maximum possible stimulating current (<xref ref-type="bibr" rid="ref105">Szostak et al., 2017</xref>). The rational impedance magnitude of electrodes at 1&#x2009;kHz will be needed for quality recording. At least 40&#x2013;150 k&#x03A9; is necessary in order to achieve the selective detection of the action potential from a single unit, but electrode&#x2019;s impedance greater than 5&#x2009;M&#x03A9; recording of neural signals is overpowered (<xref ref-type="bibr" rid="ref13">Buzs&#x00E1;ki, 2004</xref>; <xref ref-type="bibr" rid="ref79">Prasad and Sanchez, 2012</xref>).</p>
<p>Even though the electrodes implanted into tissues for recording performed well in the acute phase, the performance was inconsistent and even lost the recording ability over a longer period (<xref ref-type="bibr" rid="ref60">Merrill and Tresco, 2005</xref>). Impedance will increase as diffusional barrier is formed in the body (<xref ref-type="bibr" rid="ref60">Merrill and Tresco, 2005</xref>; <xref ref-type="bibr" rid="ref1">Abidian et al., 2010</xref>). Encapsulation failure and electrode breakage are another issue that might happen over time. A long-term <italic>in vivo</italic> study indicated that failure of the insulation material is the most significant factor in the reduction of both signal quality and impedance of implanted electrodes (<xref ref-type="bibr" rid="ref7">Barrese et al., 2013</xref>).</p>
<p>Crosstalk is another limitation of high-density recording devices, which may occur between electrodes if the space is too close, resulting in low SNR, signal transmission error, or signal loss (<xref ref-type="bibr" rid="ref59">McNamara et al., 2021</xref>; <xref ref-type="bibr" rid="ref80">Qiang et al., 2021</xref>). For neural applications, the crosstalk level has to be below 1% of the recorded signal level to make it negligible compared with the background noise (<xref ref-type="bibr" rid="ref65">Najafi et al., 1990</xref>). The electrode spacing should also be well designed, in which HDMEAs work in an excellent spatial solution with minimum crosstalk between electrodes (<xref ref-type="bibr" rid="ref20">Cruz et al., 2019</xref>).</p>
<p>In neural stimulation, the perfect electrode requires a robust storage capacity to seamlessly transmit current pulses, simultaneously curbing potential variations at the electrode/tissue nexus, thereby mitigating electrode polarization and thermal accumulation (<xref ref-type="bibr" rid="ref104">Suresh Vajrala et al., 2021</xref>), which is a task that&#x2019;s notably arduous for flexible HDMEAs.</p>
</sec>
<sec id="sec9">
<label>3.3</label>
<title>High-density interconnection challenges</title>
<p>Apart from the neural interface device itself, there&#x2019;s an inconspicuous yet critically important technical challenge: the integration of flexible sensor and backend stage (<xref ref-type="bibr" rid="ref8">Behfar et al., 2021</xref>). This unique challenge restricts system integration and directly affects the stability and performance of HDMEAs (<xref ref-type="bibr" rid="ref56">Luo et al., 2023</xref>). SNR and low latency can potentially be improved through advancements in algorithms and backend technologies (<xref ref-type="bibr" rid="ref11">Boran et al., 2019</xref>; <xref ref-type="bibr" rid="ref98">Siddiqui et al., 2019</xref>; <xref ref-type="bibr" rid="ref83">RaviPrakash et al., 2020</xref>), but the wiring issue is the true critical problem that deeply troubles HDMEA designers. Traditional silicon-based probes, benefiting from the development of modern electronics, have various mature and stable connection methods. However, the flexibility of the HDMEAs itself becomes a challenge for stable connections with subsequent systems (<xref ref-type="bibr" rid="ref38">Jang et al., 2022</xref>; <xref ref-type="bibr" rid="ref62">Miyamoto et al., 2022</xref>). Setting stability aside, the hundreds or even thousands of connection points on HDMEAs make manual connections extremely difficult without specific tools or methods. This also restricts the possibility of expanding more electrodes on flexible HDMEAs (<xref ref-type="bibr" rid="ref108">Tchoe et al., 2022</xref>). The reliability issue of the soft-hard interface presents an additional challenge for making high density interconnection between flexible HDMEAs and backend electronics. The instability caused by inconsistent stress/strain concentration at the interface of two mechanically dissimilar materials can lead to delamination failure.</p>
</sec>
<sec id="sec10">
<label>3.4</label>
<title>Chemical challenges</title>
<p>In the existing literature, comprehensive reviews (<xref ref-type="bibr" rid="ref69">Oldroyd and Malliaras, 2022</xref>; <xref ref-type="bibr" rid="ref125">Zeng and Huang, 2023</xref>; <xref ref-type="bibr" rid="ref135">Ziai et al., 2023</xref>) discussed major chemical challenges of developing and applying MEAs in biological circumstances. Here we provide a concise overview. The challenges posed by the chemical environment to flexible HDMEAs are multifaceted, which include (1) the effects of the physical chemicals on electrodes, (2) the effects of the chemicals from the HDMEAs to the host tissues, and (3) stability for the long-term use. The physical intricate mix of organic and inorganic chemicals can impact the performance and longevity of the flexible HDMEAs. Despite the diverse materials and methods used in the fabrication of MEAs, many are not adequately prepared to handle the demanding physiological conditions. The physical chemical environment can threaten the stability of MEAs over both short and long durations, owing to a range of organic and inorganic reactions.</p>
<p>Additionally, the electrode&#x2019;s inherent chemical instability can be potentially harmful to the organism. Pt, for instance, has long been regarded as highly biocompatible and non-toxic. However, a recent study by <xref ref-type="bibr" rid="ref92">Shepherd et al. (2021)</xref> revealed that prolonged stimulation (lasting 6&#x2009;months with a charge density of 267 &#x03BC;C/cm<sup>2</sup>/phase) of Pt electrode arrays led to a notable production of Pt particulates. This, in turn, resulted in an escalated fibrous tissue response and weakened the quality of long-term records.</p>
</sec>
<sec id="sec11">
<label>3.5</label>
<title>Biological challenges</title>
<p>Biocompatibility is a crucial criterion for materials utilized in biosensors, ensuring they integrate harmoniously within biological environments. Yet, even when employing these biocompatible materials, inherent biological challenges continue to arise and need addressing (<xref ref-type="bibr" rid="ref71">Otte et al., 2022</xref>). Risks that can cause damage to the tissue and induce an acute inflammatory reaction include direct damage during surgery, mismatches between the electrode and tissue, micromovements of the electrodes, damage by released chemical from the electrodes, etc. (<xref ref-type="bibr" rid="ref2008">Kozai et al., 2015</xref>). The body&#x2019;s responses to implanted HDMEAs include acute (<xref ref-type="bibr" rid="ref78">Polikov et al., 2005</xref>; <xref ref-type="bibr" rid="ref48">Kolaya and Firestein, 2021</xref>; <xref ref-type="bibr" rid="ref117">Wu et al., 2021</xref>) and chronic (<xref ref-type="bibr" rid="ref31">Golabchi et al., 2019</xref>) immune responses and damage repair processes, involving several distinct cell populations, such as erythrocytes, glial cells, neurons, etc. The processes include:</p>
<list list-type="bullet">
<list-item>
<p>Direct damage of the target tissue caused by the implantation of electrodes. The implantation of electrodes can mechanically cut or tear the target tissue, resulting in direct damage to local cells and blood vessels. This can lead to the entry of blood components (normally blocked by the blood&#x2013;brain barrier) into brain tissue. Serum proteins, such as fibrinogen and albumin, adhere onto the surface of the electrode (<xref ref-type="bibr" rid="ref48">Kolaya and Firestein, 2021</xref>). If the electrode materials of the HDMEAs are not biocompatible, they can cause local cell poisoning, irritation, and edema or even death. This, in turn, will further increase hydrostatic pressure around the electrode and harm more neurons, affecting the HDMEAs from collecting effective neuronal electrophysiological signals.</p>
</list-item>
<list-item>
<p>Acute inflammatory reaction. The earliest inflammatory response can be caused by the erythrocytes, clotting, activated platelets, and blood vessels releasing factors due to vascular damage (<xref ref-type="bibr" rid="ref78">Polikov et al., 2005</xref>; <xref ref-type="bibr" rid="ref117">Wu et al., 2021</xref>). Serum proteins promote the activation of microglia and macrophages, which then cause inflammation near the electrode surface (<xref ref-type="bibr" rid="ref48">Kolaya and Firestein, 2021</xref>). Microglia cells, one of the major glial cell types involved in wound healing response in brain, are activated after implantation and release a large number of chemicals, including neurotoxic factors such as chemokines, cytokines, reactive oxygen species, and neurotransmitters. Neurons near the electrode (about 100&#x2009;&#x03BC;m around the electrode, affected by the implantation process) suffer from direct damage and injury from these cytokines or exogenous chemicals, thereby resulting in a decrease in neurons around the electrodes. As such malfunction of the electrode can happen among the surviving neurons (<xref ref-type="bibr" rid="ref2008">Kozai et al., 2015</xref>).</p>
</list-item>
<list-item>
<p>Chronic body response. Chronic body response to HDMEAs is mediated by active astrocytes and activated microglia. After the early wound healing, activated microglia around the electrodes releases enzymes and reactive oxygen species to destroy external substances, which are eventually phagocytosed by microglia. Microglia also regulates the production of extracellular matrix (ECM) proteins which contribute to the formation of glial scars. Some external substances that cannot be cleared by microglia, such as implanted electrodes, will lead to further immune activation and glial cell proliferation. Ultimately, astrocytes proliferate and lead to the formation of glial scars around the electrode, preventing further damage. The presence of the probe in the tissue can trigger a continued foreign body response (<xref ref-type="bibr" rid="ref115">Ward et al., 2009</xref>), especially when a mismatch exists between the electrode and tissue and micromovements happened (<xref ref-type="bibr" rid="ref44">Karumbaiah et al., 2012</xref>; <xref ref-type="bibr" rid="ref77">Polanco et al., 2016</xref>). Neurons lose their electrical activity after surviving from acute reaction (<xref ref-type="bibr" rid="ref1">Abidian et al., 2010</xref>), resulting in reduced signal sources. The formation of glial scar can isolate the electrode from the surrounding neurons, reducing signal transmission by increasing the impedance of the tissue-electrode interface (<xref ref-type="bibr" rid="ref31">Golabchi et al., 2019</xref>) and the distance between the electrode and target neurons (<xref ref-type="bibr" rid="ref82">Rao et al., 2012</xref>).</p>
</list-item>
</list>
</sec>
</sec>
<sec id="sec12">
<label>4</label>
<title>Strategies and advances in developing next-generation flexible HDMEAs for closed-loop BMIs</title>
<sec id="sec13">
<label>4.1</label>
<title>Material advancement</title>
<p>Recent advancements in HDMEAs involve utilizing new materials for substrate and/or electroactive components or innovating with traditional materials to endow them with flexible properties. Compared to traditional materials, the newly developed materials possess unique properties specifically designed to address the demands of creating flexible HDMEAs. These properties include enhanced stretchability, better mechanical control, greater flexibility, and superior conductivity, among other advantageous characteristics. As a result, they are better equipped to tackle challenges in the mechanical, electrical, chemical, or biological domains. Some reviews by <xref ref-type="bibr" rid="ref29">Gablech and Glowacki (2023)</xref> and <xref ref-type="bibr" rid="ref110">Tringides and Mooney (2022)</xref> have been discussed about the material advances in MEAs development, thus we will just give an overview in this part.</p>
<p>To enhance biocompatibility, flexibility, and overall performance in neural interfaces, the advancement of substrate materials for flexible HDMEAs has incorporated innovative options such as hydrogels, silk, and polymers. Hydrogels, networks of hydrophilic, cross-linked polymer chains, have emerged as promising candidates for the next generation of bioelectronic interfaces due to their mechanical property similarity to biological tissue and versatility across electrical, mechanical, and bioengineering fields (<xref ref-type="bibr" rid="ref130">Zhang and Khademhosseini, 2017</xref>; <xref ref-type="bibr" rid="ref75">Park et al., 2021</xref>). Nevertheless, hydrogels also present challenges as substrate materials for flexible HDMEAs. Hydrogels&#x2019; low Young&#x2019;s modulus can cause mechanical instability and deformation, their susceptibility to swelling and dehydration may alter interface stability, and their fabrication complexity restricts shaping for varied applications. By using the natural silk as an optical waveguide material, <xref ref-type="bibr" rid="ref132">Zhou et al. (2022)</xref> presented and flexible opto-electro neural probe, in which electrode arrays of 128 recording channels were integrated on a single probe (<xref ref-type="fig" rid="fig4">Figure 4A</xref>). Silk has high transparency, excellent biocompatibility, and mechanical controllability. The Silk-Optrode probe, upon hydration of the silk optical fiber, autonomously adapts to its post-implantation environment, minimizing its mechanical stiffness to facilitate high-fidelity brain insertion while preserving mechanical compliance with adjacent tissue.</p>
<p>To improve the flexibility of the conductive parts, graphene (<xref ref-type="bibr" rid="ref102">Sun et al., 2021</xref>), carbon nanotubes (CNTs) (<xref ref-type="bibr" rid="ref95">Shih et al., 2020</xref>; <xref ref-type="bibr" rid="ref34">He et al., 2021</xref>), and conducting polymers (CPs), such as PEDOT: PSS (<xref ref-type="bibr" rid="ref49">Kshirsagar et al., 2019</xref>) have been developed for neural interfaces. Graphene, renowned for its notable flexibility and electrical conductivity, has become a pivotal material in neuronal interface studies and has been utilized to fabricate a range of flexible and stretchable electronic devices (<xref ref-type="bibr" rid="ref73">Park et al., 2018</xref>). Still, it is vital to concurrently acknowledge and investigate its potential drawbacks, including long-term <italic>in vivo</italic> toxicity. Pure PEDOT: PSS hydrogels is brittle yet presents a high conductivity on the level of &#x2248; 40&#x2009;S/cm. However, <xref ref-type="bibr" rid="ref52">Li et al. (2022)</xref> created a highly conductive and stretchable double-network (DN) conducting polymer hydrogel from PEDOT: PSS and poly (vinyl alcohol; PVA) and achieved through <italic>in situ</italic> aggregation and densification, offering promising characteristics like high PEDOT: PSS content, electrochemical properties, and biocompatibility for potential use in bioelectronic applications (<xref ref-type="fig" rid="fig4">Figure 4B</xref>). <xref ref-type="bibr" rid="ref51">Lee et al. (2022)</xref> developed flexible and transparent ultrathin (&#x003C;10&#x2009;nm) gold MEAs by using a biocompatible polyelectrolyte multilayer (PEM) metallic film nucleation-inducing seed layer (<xref ref-type="fig" rid="fig2">Figure 2C</xref>). With the polymer seed layer, the ultra-thin gold film created through thermal evaporation exhibits effective conductivity, along with high optical transparency and superior mechanical flexibility. Furthermore, liquid metals (notably eutectic gallium&#x2013;indium, EGaIn) have garnered significant interest in the realm of stretchable biodevices (<xref ref-type="bibr" rid="ref24">Dong et al., 2021</xref>), due to their exceptional mechanical attributes, electrical conductivity, and biocompatibility.</p>
</sec>
<sec id="sec14">
<label>4.2</label>
<title>Design in geometries and shapes</title>
<p>The utilization of dual-side design has emerged as a vital strategy to increase the electrode density in flexible neural interface applications across several research papers. By employing a dual-side design, it is possible to enhance electrode density without enlarging the probe&#x2019;s dimensions or reducing electrode size, thereby circumventing associated electrical challenges. <xref ref-type="bibr" rid="ref87">Scholten et al. (2020)</xref> introduced a novel polymer-based microelectrode array with an impressive 512 platinum recording electrodes, optimized for chronic recordings in the brains of behaving rats, and showcase advancements in polymer microfabrication and back-side electrode patterning. In the work of <xref ref-type="bibr" rid="ref47">Kim et al. (2023)</xref>, a dual-side fabricated multimodal polymer neural probe was developed, featuring gold and platinum microelectrodes. Although a strategy of using multilayer with a sacrificial layer on the bottom could fabricate dual-sided flexible HDMEAs, it introduces challenges, such as misalignment during the multiple lithography processes (<xref ref-type="bibr" rid="ref655">Liu et al., n.d.</xref>). A more straightforward and efficient method is still needed. Soft and stretchable electronics have been developed to create HDMEAs that can better conform to the brain&#x2019;s surface and accommodate its natural movements. With some ingenious designs, these devices not only exhibit greater flexibility and stretchability but also reduce mechanical issues common in traditional designs. Moreover, due to improved contact between the electrode and tissue, they can ensure enhanced electrical performance. The stretchable opto-electric integrated neural interface (SOENI) is designed to align with the mouse brain&#x2019;s somatomotor and somatosensory cortices (<xref ref-type="bibr" rid="ref40">Ji et al., 2020a</xref>). It features a 3 &#x00D7; 3 microelectrode grid, 2 &#x00D7; 2 micro-LEDs, and a large reference electrode. Embedded within two silicone elastomer layers, the SOENI combines photostimulation and recording electrodes, with microscale light emitting diodes (LEDs) connected using a flip-on-chip method, aligning their illuminated surfaces with the microelectrode sites. Serpentine-shaped metal interconnecting wires were designed to improve the stretchability. Similar serpentine structures were also used in some other latest microsystems (<xref ref-type="bibr" rid="ref41">Ji et al., 2020b</xref>; <xref ref-type="bibr" rid="ref118">Xiang et al., 2022</xref>).</p>
<p>Mesh-like electrode designs have also been explored in order to improve the conformability of HDMEAs to the brain&#x2019;s surface and minimize mechanical stress on cell or tissue. For example, <xref ref-type="bibr" rid="ref50">Le Floch et al. (2022)</xref> reported &#x201C;tissue-like&#x201D; stretchable mesh nanoelectronics designed to align with brain organoids&#x2019; mechanical properties, which can be folded into 3D structures by progenitor or stem cells, facilitating three months electrophysiological measurements. Inspired by implantable mesh electronics and organoid polymer scaffold growth, <xref ref-type="bibr" rid="ref58">McDonald et al. (2023)</xref> developed suspended mesh microelectrode arrays for neural organoids, incorporating four wells, each containing a mesh and 61 microelectrodes, which are adept for low-noise recordings and electrical stimulation with their sub-100 k&#x03A9; impedance at 1&#x2009;kHz. These HDMEAs emphasized their ability to improve conformability to the brain&#x2019;s surface and minimize mechanical stress. These designs represent a significant shift toward structures that are more adaptable and less invasive than traditional electrodes.</p>
</sec>
<sec id="sec15">
<label>4.3</label>
<title>Surface modification strategies</title>
<p>Surface modification strategies not only address the challenges of electrical, mechanical, and biological compatibility but also significantly enhance the overall performance of HDMEAs in closed-loop BMIs. A common method of surface modification is adding a layer of special materials on the electrode surface to change the electrode&#x2019;s properties. These materials include metals (<xref ref-type="bibr" rid="ref35">Hempel et al., 2017</xref>), conductive polymers (<xref ref-type="bibr" rid="ref9">Bianchi et al., 2021</xref>), nanostructures (<xref ref-type="bibr" rid="ref28">Fattahi et al., 2014</xref>; <xref ref-type="bibr" rid="ref6">Barai et al., 2018</xref>), and bioactive substances (<xref ref-type="bibr" rid="ref112">Vitale et al., 2018</xref>; <xref ref-type="bibr" rid="ref30">Golabchi et al., 2020</xref>). PEDOT and its derivative are used to improve the electrical properties (<xref ref-type="bibr" rid="ref35">Hempel et al., 2017</xref>; <xref ref-type="bibr" rid="ref655">Liu et al., n.d.</xref>) and modify the physical properties, such as transmittance (<xref ref-type="bibr" rid="ref123">Yang et al., 2021b</xref>). The application of CNTs significantly increases the surface area, thereby increasing the charge storage capacity and the injection limit, with other benefits such as good adhesion, non-toxicity, and stable properties (<xref ref-type="bibr" rid="ref28">Fattahi et al., 2014</xref>; <xref ref-type="bibr" rid="ref6">Barai et al., 2018</xref>). <xref ref-type="bibr" rid="ref121">Yang et al. (2023)</xref> used polypyrrole/carboxylated single-walled carbon nanotubes (PPy/SWCNTs) nanocomposites for electrode modification. The nanocomposites not only improved the performance of microelectrodes with low impedance (60.3 &#x00B1; 28.8 kappa O) and small phase delay (&#x2212;32.8 &#x00B1; 4.4 degrees), but also presented stability for <italic>in vivo</italic> stimulation and recording for 21&#x2009;days, as shown in <xref ref-type="fig" rid="fig3">Figure 3B</xref>. Neuroadhesive protein coating improves the chronic performance of neuroelectronics in the mouse brain (<xref ref-type="bibr" rid="ref30">Golabchi et al., 2020</xref>).</p>
<p>Innovations in surface topology, with or without additional coating, have demonstrated improved recording quality compared to traditional planar electrodes. Mushroom-shaped microelectrodes improved the recording quality compared to planar MEA (<xref ref-type="bibr" rid="ref97">Shmoel et al., 2016</xref>). The enhanced microscale wrinkles on microelectrodes were obtained by oil extraction from the elastic substrate and electroplating modified materials PEDOT: PSS and platinum black (Pt-black) on the wrinkled microelectrode sites improve the total device performance in electrocorticography (ECoG) signal recording without causing any cracks, delamination, or exfoliation (<xref ref-type="bibr" rid="ref93">Shi et al., 2021</xref>).</p>
</sec>
<sec id="sec16">
<label>4.4</label>
<title>Connection strategies for flexible HDMEAs</title>
<p>Anisotropic conductive film (ACF) bonding process has become a feasible approach to address the high-density interconnection challenges of flexible devices (<xref ref-type="bibr" rid="ref21">Dagdeviren et al., 2014</xref>; <xref ref-type="bibr" rid="ref56">Luo et al., 2023</xref>), yet, the high-temperature, high-pressure bonding process limits the use of some flexible materials. However, <xref ref-type="bibr" rid="ref37">Hwang et al. (2021)</xref> introduced a stretchable anisotropic conductive film (S-ACF) capable of connecting high-resolution stretchable circuit lines to various electrodes, addressing the challenge of high-resolution stretchable interfacing at low temperatures through conductive microparticles in a thermoplastic film (<xref ref-type="fig" rid="fig3">Figure 3D</xref>).</p>
<p>Diverging from ACF, manufacturing a standard flat flexible cable (FFC) directly on the sensor to accommodate different connectors is also a viable approach. The zero insertion force (ZIF) connector can address the connection issue to some extent (<xref ref-type="bibr" rid="ref99">Song et al., 2019</xref>; <xref ref-type="bibr" rid="ref43">Kang et al., 2022</xref>), especially with its mechanical connection features, allowing sensors to be easily disconnected. This provides many conveniences for wearable, disposable HDMEAs. The easy-to-replace feature also makes it convenient for researchers to replace damaged sensors, which is especially valuable in some destructive experiments. However, this method seems a bit cumbersome when facing thousands of connection points. Especially the weight, size, and cost of the ZIF connector further restrict its application scenarios. The simplest method is to directly flip the sensor and affix the designed FFC directly onto a printed circuit board (PCB) or flexible PCB with conductive adhesive (<xref ref-type="bibr" rid="ref8">Behfar et al., 2021</xref>). This method is straightforward, low-cost, and very suitable for HDMEAs with a smaller number of electrodes or in the prototype stage.</p>
<p>The instability of soft-hard interface can be addressed by either enhancing the adhesion between the materials or avoiding sudden changes from soft to hard, that is, by adding an intermediate layer/buffer layer to mitigate the transition. Ideally speaking, making the entire backend into flexible devices to form a fully flexible system would be best. By eliminating the differences between materials, this problem can be completely addressed. Zhang et al. report a capacitive pressure sensor (<xref ref-type="bibr" rid="ref131">Zhang et al., 2022</xref>). Impressively, this sensor used CNT-doped PDMS, achieving both electrode and insulating materials using CNT-doped PDMS through tuning different doping concentrations. To some extent, this realized part of the full-flexibility goal. Such partial implementation alone resulted in surprisingly stable performance; the device remained stable even after 100,000 deformation cycles. This further confirms that aiming for a fully flexible design is undoubtedly a solution to the soft-hard interface issue.</p>
</sec>
<sec id="sec17">
<label>4.5</label>
<title>Advances in fabrication techniques and strategies</title>
<p>Various recent fabricating strategies, including multi-layer strategies (<xref ref-type="bibr" rid="ref76">Pimenta et al., 2021</xref>) and dual-sided micropatterning (<xref ref-type="bibr" rid="ref109">Tooker et al., 2012</xref>; <xref ref-type="bibr" rid="ref76">Pimenta et al., 2021</xref>; <xref ref-type="bibr" rid="ref47">Kim et al., 2023</xref>), have been proposed to attain high-density probe capabilities without enlarging the polymer neural probes&#x2019; dimensions. Meanwhile, the advances in fabrication techniques also facilitate the development of flexible HDMEAs. Traditional fabrication techniques, such as photolithography, have significantly advanced the development of flexible HDMEAs, yet they come with limitations, including intricate processes, challenges in fabricating 3D structures, and precision constraints. Recently, emerging technologies, such as precise laser ablation and laser lithography, have introduced more streamlined, direct, and even more accurate methods for making complex electrode structures.</p>
<p>Laser ablation, or laser patterning, facilitates the streamlined fabrication of planar and 3D microelectrodes without the need for photolithography and etching by eschewing multi-step procedures for a more straightforward implementation (<xref ref-type="bibr" rid="ref107">Tanwar et al., 2022</xref>). For example, soft and flexible gold microelectrodes with widths down to 3&#x2009;&#x03BC;m were fabricated on a pliable PDMS substrate through a combination of supersonic cluster beam deposition and femtosecond laser processing (<xref ref-type="bibr" rid="ref25">Dotan et al., 2021</xref>). Inkjet printing, garnering popularity for creating MEAs by directly depositing microelectrodes onto the substrate through single-step fabrication, facilitates the use of softer substrates compared to photolithography and permits the use of alternative conductive inks like PEDOT: PSS for printing conductive lines on soft substrate directly (<xref ref-type="bibr" rid="ref57">Mandelli et al., 2021</xref>; <xref ref-type="bibr" rid="ref45">Kim et al., 2022</xref>). However, it does come with the drawback of being notably expensive.</p>
<p>To effectively reduce crosstalk between interconnects, it is necessary to increase the distance or add a shield layer (<xref ref-type="bibr" rid="ref80">Qiang et al., 2021</xref>; <xref ref-type="bibr" rid="ref67">Naughton et al., 2022</xref>). Spacing them too far apart will inevitably increase the cable width and enlarge the overall system size. The core contradiction lies between the excessive number of wires and limited space. Some designs compensate for width by adjusting thickness, that is, by using multiple layers to reduce the number of wires that each single layer needs to accommodate (<xref ref-type="bibr" rid="ref96">Shin et al., 2021</xref>; <xref ref-type="bibr" rid="ref84">Saleh et al., 2022</xref>). Passive matrix and active matrix have become the mainstream architectures to address the signal readout of the array (<xref ref-type="bibr" rid="ref61">Miccoli et al., 2019</xref>; <xref ref-type="bibr" rid="ref56">Luo et al., 2023</xref>). The passive matrix design is relatively simple, consisting of intersecting rows and columns, with sensors set at the intersections (<xref ref-type="bibr" rid="ref103">Sundaram et al., 2019</xref>; <xref ref-type="bibr" rid="ref43">Kang et al., 2022</xref>). However, the crosstalk between sensors limits the quality of the signal. The active matrix addresses the crosstalk issue by adding switching units, such as diodes, to the electrodes (<xref ref-type="bibr" rid="ref74">Park et al., 2019</xref>; <xref ref-type="bibr" rid="ref33">Gwon et al., 2022</xref>). With the ideal performance comes complex circuit design requirements and internal structural issues. Nowadays, the flexible active matrix has become a mature technology used in the commercial display industry, which is worthy of designers&#x2019; study.</p>
</sec>
</sec>
<sec sec-type="conclusions" id="sec18">
<label>5</label>
<title>Conclusion</title>
<p>In conclusion, flexible HDMEAs have emerged as a promising technology for closed-loop BMIs, offering higher resolution, greater selectivity, and improved biocompatibility compared to traditional rigid electrodes. However, there are still many challenges that need to be overcome in the development and application of these arrays, such as mechanical and electrical stability, biocompatibility, power and energy efficiency, and clinical translation.</p>
<p>In the realm of future research directions for flexible HDMEAs, we identify several key research directions. The development of new materials is crucial, particularly for more ideal flexible substrates, conductive materials, and packaging solutions. These materials need to be stable, efficient, and durable for long-term use. Strategies for surface modification of the electrode are also essential, ensuring efficiency and stability over extended periods. Advances in fabrication, such as precise laser patterning and 3D printing, will greatly facilitate the creation of HDMEAs with complex structures and enhanced functionalities. In terms of connection technology, integrating wireless systems and remote monitoring will increase the clinical applicability of these devices. Investigating the use of flexible HDMEAs within closed-loop BMIs, and their application across a range of biological systems from rodents and humans to smaller organisms like insects, presents new opportunities in comprehending neural mechanisms, disease diagnosis and treatment, and biodetection.</p>
</sec>
<sec sec-type="author-contributions" id="sec19">
<title>Author contributions</title>
<p>XL: Conceptualization, Methodology, Writing &#x2013; original draft, Writing &#x2013; review &#x0026; editing. YG: Writing &#x2013; original draft, Writing &#x2013; review &#x0026; editing. ZJ: Data curation, Writing &#x2013; review &#x0026; editing. TS: Data curation, Writing &#x2013; original draft. WL: Conceptualization, Methodology, Resources, Supervision, Writing &#x2013; original draft, Writing &#x2013; review &#x0026; editing.</p>
</sec>
</body>
<back>
<sec sec-type="funding-information" id="sec20">
<title>Funding</title>
<p>The author(s) declare that no financial support was received for the research, authorship, and/or publication of this article.</p>
</sec>
<sec sec-type="COI-statement" id="sec21">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec id="sec100" sec-type="disclaimer">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ref-list>
<title>References</title>
<ref id="ref1">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Abidian</surname> <given-names>M. R.</given-names></name> <name><surname>Corey</surname> <given-names>J. M.</given-names></name> <name><surname>Kipke</surname> <given-names>D. R.</given-names></name> <name><surname>Martin</surname> <given-names>D. C.</given-names></name></person-group> (<year>2010</year>). <article-title>Conducting-polymer nanotubes improve electrical properties, mechanical adhesion, neural attachment, and neurite outgrowth of neural electrodes</article-title>. <source>Small</source> <volume>6</volume>, <fpage>421</fpage>&#x2013;<lpage>429</lpage>. doi: <pub-id pub-id-type="doi">10.1002/smll.200901868</pub-id>, PMID: <pub-id pub-id-type="pmid">20077424</pub-id></citation>
</ref>
<ref id="ref2">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Adams</surname> <given-names>C.</given-names></name> <name><surname>Mathieson</surname> <given-names>K.</given-names></name> <name><surname>Gunning</surname> <given-names>D.</given-names></name> <name><surname>Cunningham</surname> <given-names>W.</given-names></name> <name><surname>Rahman</surname> <given-names>M.</given-names></name> <name><surname>Morrison</surname> <given-names>J. D.</given-names></name> <etal/></person-group>. (<year>2005</year>). <article-title>Development of flexible arrays for in vivo neuronal recording and stimulation</article-title>. <source>Nuclear Instru. Methods Phys. Res. Sect. Accel. Spec. Detect. Assoc. Equip.</source> <volume>546</volume>, <fpage>154</fpage>&#x2013;<lpage>159</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.nima.2005.03.014</pub-id></citation>
</ref>
<ref id="ref3">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ajiboye</surname> <given-names>A. B.</given-names></name> <name><surname>Willett</surname> <given-names>F. R.</given-names></name> <name><surname>Young</surname> <given-names>D. R.</given-names></name> <name><surname>Memberg</surname> <given-names>W. D.</given-names></name> <name><surname>Murphy</surname> <given-names>B. A.</given-names></name> <name><surname>Miller</surname> <given-names>J. P.</given-names></name> <etal/></person-group>. (<year>2017</year>). <article-title>Restoration of reaching and grasping movements through brain-controlled muscle stimulation in a person with tetraplegia: a proof-of-concept demonstration</article-title>. <source>Lancet</source> <volume>389</volume>, <fpage>1821</fpage>&#x2013;<lpage>1830</lpage>. doi: <pub-id pub-id-type="doi">10.1016/S0140-6736(17)30601-3</pub-id>, PMID: <pub-id pub-id-type="pmid">28363483</pub-id></citation>
</ref>
<ref id="ref4">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ang</surname> <given-names>K. K.</given-names></name> <name><surname>Chua</surname> <given-names>K. S. G.</given-names></name> <name><surname>Phua</surname> <given-names>K. S.</given-names></name> <name><surname>Wang</surname> <given-names>C.</given-names></name> <name><surname>Chin</surname> <given-names>Z. Y.</given-names></name> <name><surname>Kuah</surname> <given-names>C. W. K.</given-names></name> <etal/></person-group>. (<year>2015</year>). <article-title>A randomized controlled trial of EEG-based motor imagery brain-computer interface robotic rehabilitation for stroke</article-title>. <source>Clin. EEG Neurosci.</source> <volume>46</volume>, <fpage>310</fpage>&#x2013;<lpage>320</lpage>. doi: <pub-id pub-id-type="doi">10.1177/1550059414522229</pub-id>, PMID: <pub-id pub-id-type="pmid">24756025</pub-id></citation>
</ref>
<ref id="ref5">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Araki</surname> <given-names>T.</given-names></name> <name><surname>Bongartz</surname> <given-names>L. M.</given-names></name> <name><surname>Kaiju</surname> <given-names>T.</given-names></name> <name><surname>Takemoto</surname> <given-names>A.</given-names></name> <name><surname>Tsuruta</surname> <given-names>S.</given-names></name> <name><surname>Uemura</surname> <given-names>T.</given-names></name> <etal/></person-group>. (<year>2020</year>). <article-title>Flexible neural interfaces for brain implants-the pursuit of thinness and high density</article-title>. <source>Flex. Print. Electr.</source> <volume>5</volume>:<fpage>043002</fpage>. doi: <pub-id pub-id-type="doi">10.1088/2058-8585/abc3ca</pub-id></citation>
</ref>
<ref id="ref6">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Barai</surname> <given-names>H. R.</given-names></name> <name><surname>Banerjee</surname> <given-names>A. N.</given-names></name> <name><surname>Bai</surname> <given-names>F.</given-names></name> <name><surname>Joo</surname> <given-names>S. W.</given-names></name></person-group> (<year>2018</year>). <article-title>Surface modification of titania nanotube arrays with crystalline manganese-oxide nanostructures and fabrication of hybrid electrochemical electrode for high-performance supercapacitors</article-title>. <source>J. Ind. Eng. Chem.</source> <volume>62</volume>, <fpage>409</fpage>&#x2013;<lpage>417</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.jiec.2018.01.023</pub-id></citation>
</ref>
<ref id="ref7">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Barrese</surname> <given-names>J. C.</given-names></name> <name><surname>Rao</surname> <given-names>N.</given-names></name> <name><surname>Paroo</surname> <given-names>K.</given-names></name> <name><surname>Triebwasser</surname> <given-names>C.</given-names></name> <name><surname>Vargas-Irwin</surname> <given-names>C.</given-names></name> <name><surname>Franquemont</surname> <given-names>L.</given-names></name> <etal/></person-group>. (<year>2013</year>). <article-title>Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates</article-title>. <source>J. Neural Eng.</source> <volume>10</volume>:<fpage>066014</fpage>. doi: <pub-id pub-id-type="doi">10.1088/1741-2560/10/6/066014</pub-id>, PMID: <pub-id pub-id-type="pmid">24216311</pub-id></citation>
</ref>
<ref id="ref8">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Behfar</surname> <given-names>M. H.</given-names></name> <name><surname>Khorramdel</surname> <given-names>B.</given-names></name> <name><surname>Korhonen</surname> <given-names>A.</given-names></name> <name><surname>Jansson</surname> <given-names>E.</given-names></name> <name><surname>Leinonen</surname> <given-names>A.</given-names></name> <name><surname>Tuomikoski</surname> <given-names>M.</given-names></name> <etal/></person-group>. (<year>2021</year>). <article-title>Failure mechanisms in flip-chip bonding on stretchable printed electronics</article-title>. <source>Adv. Eng. Mater.</source> <volume>23</volume>:<fpage>2100264</fpage>. doi: <pub-id pub-id-type="doi">10.1002/adem.202100264</pub-id></citation>
</ref>
<ref id="ref9">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bianchi</surname> <given-names>M.</given-names></name> <name><surname>De Salvo</surname> <given-names>A.</given-names></name> <name><surname>Asplund</surname> <given-names>M.</given-names></name> <name><surname>Carli</surname> <given-names>S.</given-names></name> <name><surname>Lauro</surname> <given-names>M. D.</given-names></name> <name><surname>Schulze-Bonhage</surname> <given-names>A.</given-names></name> <etal/></person-group>. (<year>2021</year>). <article-title>Conductive polymers for bidirectional neural interfaces: fundamentals aspects and <italic>in vivo</italic> applications</article-title>. <source>TechRxiv</source></citation>
</ref>
<ref id="ref10">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bonafe</surname> <given-names>F.</given-names></name>
</person-group> (<year>2022</year>). <article-title>Flexible microelectrode array based on PEDOT:PSS for neural recording and stimulation</article-title>. <source>Nuovo Cimento c-Colloquia Comm. Phys.</source>:<fpage>45</fpage>.</citation>
</ref>
<ref id="ref11">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Boran</surname> <given-names>E.</given-names></name> <name><surname>Ramantani</surname> <given-names>G.</given-names></name> <name><surname>Krayenb&#x00FC;hl</surname> <given-names>N.</given-names></name> <name><surname>Schreiber</surname> <given-names>M.</given-names></name> <name><surname>K&#x00F6;nig</surname> <given-names>K.</given-names></name> <name><surname>Fedele</surname> <given-names>T.</given-names></name> <etal/></person-group>. (<year>2019</year>). <article-title>High-density ECoG improves the detection of high frequency oscillations that predict seizure outcome</article-title>. <source>Clin. Neurophysiol.</source> <volume>130</volume>, <fpage>1882</fpage>&#x2013;<lpage>1888</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.clinph.2019.07.008</pub-id>, PMID: <pub-id pub-id-type="pmid">31404865</pub-id></citation>
</ref>
<ref id="ref12">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Brown</surname> <given-names>M. A.</given-names></name> <name><surname>Zappitelli</surname> <given-names>K. M.</given-names></name> <name><surname>Singh</surname> <given-names>L.</given-names></name> <name><surname>Yuan</surname> <given-names>R. C.</given-names></name> <name><surname>Bemrose</surname> <given-names>M.</given-names></name> <name><surname>Brogden</surname> <given-names>V.</given-names></name> <etal/></person-group>. (<year>2023</year>). <article-title>Direct laser writing of 3D electrodes on flexible substrates</article-title>. <source>Nat. Commun.</source> <volume>14</volume>:<fpage>3610</fpage>. doi: <pub-id pub-id-type="doi">10.1038/s41467-023-39152-7</pub-id>, PMID: <pub-id pub-id-type="pmid">37330565</pub-id></citation>
</ref>
<ref id="ref13">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Buzs&#x00E1;ki</surname> <given-names>G.</given-names></name>
</person-group> (<year>2004</year>). <article-title>Large-scale recording of neuronal ensembles</article-title>. <source>Nat. Neurosci.</source> <volume>7</volume>, <fpage>446</fpage>&#x2013;<lpage>451</lpage>. doi: <pub-id pub-id-type="doi">10.1038/nn1233</pub-id></citation>
</ref>
<ref id="ref14">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Castrioto</surname> <given-names>A.</given-names></name> <name><surname>Moro</surname> <given-names>E.</given-names></name></person-group> (<year>2013</year>). <article-title>New targets for deep brain stimulation treatment of Parkinson&#x2019;s disease</article-title>. <source>Expert. Rev. Neurother.</source> <volume>13</volume>, <fpage>1319</fpage>&#x2013;<lpage>1328</lpage>. doi: <pub-id pub-id-type="doi">10.1586/14737175.2013.859987</pub-id></citation>
</ref>
<ref id="ref15">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chik</surname> <given-names>G. K. K.</given-names></name> <name><surname>Xiao</surname> <given-names>N.</given-names></name> <name><surname>Ji</surname> <given-names>X.</given-names></name> <name><surname>Tsang</surname> <given-names>A. C. O.</given-names></name> <name><surname>Leung</surname> <given-names>G. K. K.</given-names></name> <name><surname>Zhang</surname> <given-names>S.</given-names></name> <etal/></person-group>. (<year>2022</year>). <article-title>Flexible multichannel neural probe developed by Electropolymerization for localized stimulation and sensing</article-title>. <source>Adv. Mater. Technol.</source> <volume>7</volume>:<fpage>2200143</fpage>. doi: <pub-id pub-id-type="doi">10.1002/admt.202200143</pub-id></citation>
</ref>
<ref id="ref16">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Choi</surname> <given-names>B.-J.</given-names></name> <name><surname>Kim</surname> <given-names>J.-H.</given-names></name> <name><surname>Yang</surname> <given-names>W.-J.</given-names></name> <name><surname>Han</surname> <given-names>D.-J.</given-names></name> <name><surname>Park</surname> <given-names>J.</given-names></name> <name><surname>Park</surname> <given-names>D.-W.</given-names></name></person-group> (<year>2020</year>). <article-title>Parylene-based flexible microelectrode arrays for the electrical recording of muscles and the effect of electrode size</article-title>. <source>Appl. Sci.</source> <volume>10</volume>:<fpage>7364</fpage>. doi: <pub-id pub-id-type="doi">10.3390/app10207364</pub-id></citation>
</ref>
<ref id="ref17">
<citation citation-type="other"><person-group person-group-type="author"><name><surname>Chong</surname> <given-names>H.</given-names></name>
</person-group> (<year>2022</year>). Development of novel COMPOSITE and multilayered materials for PDMS-based, minimally-invasive flexible implantable microsystems. Case Western Reserve University.</citation>
</ref>
<ref id="ref18">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Chou</surname> <given-names>K. L.</given-names></name> <name><surname>Grube</surname> <given-names>S.</given-names></name> <name><surname>Patil</surname> <given-names>P. G.</given-names></name></person-group> (<year>2011</year>). <source>Deep brain stimulation: a new life for people with Parkinson's, dystonia, and essential tremor.</source> <publisher-loc>New York, NY</publisher-loc>: <publisher-name>Demos Medical Publishing</publisher-name>.</citation>
</ref>
<ref id="ref19">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Cointe</surname> <given-names>C.</given-names></name> <name><surname>Laborde</surname> <given-names>A.</given-names></name> <name><surname>Nowak</surname> <given-names>L. G.</given-names></name> <name><surname>Arvanitis</surname> <given-names>D. N.</given-names></name> <name><surname>Bourrier</surname> <given-names>D.</given-names></name> <name><surname>Bergaud</surname> <given-names>C.</given-names></name> <etal/></person-group>. (<year>2022</year>). <article-title>Scalable batch fabrication of ultrathin flexible neural probes using a bioresorbable silk layer</article-title>. <source>Microsys. Nanoeng.</source> <volume>8</volume>, <fpage>1</fpage>&#x2013;<lpage>11</lpage>. doi: <pub-id pub-id-type="doi">10.1038/s41378-022-00353-7</pub-id></citation>
</ref>
<ref id="ref20">
<citation citation-type="confproc"><person-group person-group-type="author"><name><surname>Cruz</surname> <given-names>M.F.P.</given-names></name> <name><surname>Vomero</surname> <given-names>M.</given-names></name> <name><surname>Zucchini</surname> <given-names>E.</given-names></name> <name><surname>Delfino</surname> <given-names>E.</given-names></name> <name><surname>Asplund</surname> <given-names>M.</given-names></name> <name><surname>Stieglitz</surname> <given-names>T.</given-names></name> <etal/></person-group>. (<year>2019</year>). "<article-title>Can crosstalk compromise the recording of high-frequency neural signals?</article-title>", In: <conf-name>9th IEEE/EMBS International Conference on Neural Engineering (NER)</conf-name>, <fpage>924</fpage>&#x2013;<lpage>927</lpage>.</citation>
</ref>
<ref id="ref21">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dagdeviren</surname> <given-names>C.</given-names></name> <name><surname>Yang</surname> <given-names>B. D.</given-names></name> <name><surname>Su</surname> <given-names>Y.</given-names></name> <name><surname>Tran</surname> <given-names>P. L.</given-names></name> <name><surname>Joe</surname> <given-names>P.</given-names></name> <name><surname>Anderson</surname> <given-names>E.</given-names></name> <etal/></person-group>. (<year>2014</year>). <article-title>Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm</article-title>. <source>Proc. Natl. Acad. Sci. U. S. A</source> <volume>111</volume>, <fpage>1927</fpage>&#x2013;<lpage>1932</lpage>. doi: <pub-id pub-id-type="doi">10.1073/pnas.1317233111</pub-id>, PMID: <pub-id pub-id-type="pmid">24449853</pub-id></citation>
</ref>
<ref id="ref22">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>David-Pur</surname> <given-names>M.</given-names></name> <name><surname>Bareket-Keren</surname> <given-names>L.</given-names></name> <name><surname>Beit-Yaakov</surname> <given-names>G.</given-names></name> <name><surname>Raz-Prag</surname> <given-names>D.</given-names></name> <name><surname>Hanein</surname> <given-names>Y.</given-names></name></person-group> (<year>2014</year>). <article-title>All-carbon-nanotube flexible multi-electrode array for neuronal recording and stimulation</article-title>. <source>Biomed. Microdevices</source> <volume>16</volume>, <fpage>43</fpage>&#x2013;<lpage>53</lpage>. doi: <pub-id pub-id-type="doi">10.1007/s10544-013-9804-6</pub-id>, PMID: <pub-id pub-id-type="pmid">23974529</pub-id></citation>
</ref>
<ref id="ref23">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Donati</surname> <given-names>A. R.</given-names></name> <name><surname>Shokur</surname> <given-names>S.</given-names></name> <name><surname>Morya</surname> <given-names>E.</given-names></name> <name><surname>Campos</surname> <given-names>D. S.</given-names></name> <name><surname>Moioli</surname> <given-names>R. C.</given-names></name> <name><surname>Gitti</surname> <given-names>C. M.</given-names></name> <etal/></person-group>. (<year>2016</year>). <article-title>Long-term training with a brain-machine interface-based gait protocol induces partial neurological recovery in paraplegic patients</article-title>. <source>Sci. Rep.</source> <volume>6</volume>:<fpage>30383</fpage>. doi: <pub-id pub-id-type="doi">10.1038/srep30383</pub-id>, PMID: <pub-id pub-id-type="pmid">27513629</pub-id></citation>
</ref>
<ref id="ref24">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dong</surname> <given-names>R.</given-names></name> <name><surname>Liu</surname> <given-names>X.</given-names></name> <name><surname>Cheng</surname> <given-names>S.</given-names></name> <name><surname>Tang</surname> <given-names>L.</given-names></name> <name><surname>Chen</surname> <given-names>M.</given-names></name> <name><surname>Zhong</surname> <given-names>L.</given-names></name> <etal/></person-group>. (<year>2021</year>). <article-title>Highly stretchable metal&#x2013;polymer conductor electrode Array for electrophysiology</article-title>. <source>Adv. Healthc. Mater.</source> <volume>10</volume>:<fpage>e2000641</fpage>. doi: <pub-id pub-id-type="doi">10.1002/adhm.202000641</pub-id>, PMID: <pub-id pub-id-type="pmid">32940002</pub-id></citation>
</ref>
<ref id="ref25">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dotan</surname> <given-names>T.</given-names></name> <name><surname>Berg</surname> <given-names>Y.</given-names></name> <name><surname>Migliorini</surname> <given-names>L.</given-names></name> <name><surname>Villa</surname> <given-names>S. M.</given-names></name> <name><surname>Santaniello</surname> <given-names>T.</given-names></name> <name><surname>Milani</surname> <given-names>P.</given-names></name> <etal/></person-group>. (<year>2021</year>). <article-title>Soft and flexible gold microelectrodes by supersonic cluster beam deposition and femtosecond laser processing</article-title>. <source>Microelectron. Eng.</source> <volume>237</volume>:<fpage>111478</fpage>. doi: <pub-id pub-id-type="doi">10.1016/j.mee.2020.111478</pub-id></citation>
</ref>
<ref id="ref26">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Esteban-Linares</surname> <given-names>A.</given-names></name> <name><surname>Zhang</surname> <given-names>X.</given-names></name> <name><surname>Lee</surname> <given-names>H. H.</given-names></name> <name><surname>Risner</surname> <given-names>M. L.</given-names></name> <name><surname>Weiss</surname> <given-names>S. M.</given-names></name> <name><surname>Xu</surname> <given-names>Y.-Q.</given-names></name> <etal/></person-group>. (<year>2023</year>). <article-title>Graphene-based microfluidic perforated microelectrode arrays for retinal electrophysiological studies</article-title>. <source>Lab Chip</source> <volume>23</volume>, <fpage>2193</fpage>&#x2013;<lpage>2205</lpage>. doi: <pub-id pub-id-type="doi">10.1039/D3LC00064H</pub-id>, PMID: <pub-id pub-id-type="pmid">36891773</pub-id></citation>
</ref>
<ref id="ref27">
<citation citation-type="other"><person-group person-group-type="author"><name><surname>Eunah</surname> <given-names>K.</given-names></name> <name><surname>Mih&#x00E1;ly</surname> <given-names>V.</given-names></name> <name><surname>Gy&#x00F6;rgy</surname> <given-names>B.</given-names></name> <name><surname>Euisik</surname> <given-names>Y.</given-names></name></person-group> (<year>2022</year>). flexLiTE: flexible micro-LED integrated optoelectrodes for minimally-invasive chronic deep-brain study. bioRxiv, 2022.2008.2005.503006.</citation>
</ref>
<ref id="ref28">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fattahi</surname> <given-names>P.</given-names></name> <name><surname>Yang</surname> <given-names>G.</given-names></name> <name><surname>Kim</surname> <given-names>G.</given-names></name> <name><surname>Abidian</surname> <given-names>M. R.</given-names></name></person-group> (<year>2014</year>). <article-title>A review of organic and inorganic biomaterials for neural interfaces</article-title>. <source>Adv. Mater.</source> <volume>26</volume>, <fpage>1846</fpage>&#x2013;<lpage>1885</lpage>. doi: <pub-id pub-id-type="doi">10.1002/adma.201304496</pub-id>, PMID: <pub-id pub-id-type="pmid">24677434</pub-id></citation>
</ref>
<ref id="ref29">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gablech</surname> <given-names>I.</given-names></name> <name><surname>Glowacki</surname> <given-names>E. D.</given-names></name></person-group> (<year>2023</year>). <article-title>State-of-the-art electronic materials for thin films in bioelectronics</article-title>. <source>Adv. Electr. Mater.</source> <volume>9</volume>:<fpage>2300258</fpage>. doi: <pub-id pub-id-type="doi">10.1002/aelm.202300258</pub-id></citation>
</ref>
<ref id="ref30">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Golabchi</surname> <given-names>A.</given-names></name> <name><surname>Woeppel</surname> <given-names>K. M.</given-names></name> <name><surname>Li</surname> <given-names>X.</given-names></name> <name><surname>Lagenaur</surname> <given-names>C. F.</given-names></name> <name><surname>Cui</surname> <given-names>X. T.</given-names></name></person-group> (<year>2020</year>). <article-title>Neuroadhesive protein coating improves the chronic performance of neuroelectronics in mouse brain</article-title>. <source>Biosens. Bioelectron.</source> <volume>155</volume>:<fpage>112096</fpage>. doi: <pub-id pub-id-type="doi">10.1016/j.bios.2020.112096</pub-id>, PMID: <pub-id pub-id-type="pmid">32090868</pub-id></citation>
</ref>
<ref id="ref31">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Golabchi</surname> <given-names>A.</given-names></name> <name><surname>Wu</surname> <given-names>B.</given-names></name> <name><surname>Cao</surname> <given-names>B.</given-names></name> <name><surname>Bettinger</surname> <given-names>C. J.</given-names></name> <name><surname>Cui</surname> <given-names>X. T.</given-names></name></person-group> (<year>2019</year>). <article-title>Zwitterionic polymer/polydopamine coating reduce acute inflammatory tissue responses to neural implants</article-title>. <source>Biomaterials</source> <volume>225</volume>:<fpage>119519</fpage>. doi: <pub-id pub-id-type="doi">10.1016/j.biomaterials.2019.119519</pub-id>, PMID: <pub-id pub-id-type="pmid">31600673</pub-id></citation>
</ref>
<ref id="ref32">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Golda-Cepa</surname> <given-names>M.</given-names></name> <name><surname>Engvall</surname> <given-names>K.</given-names></name> <name><surname>Hakkarainen</surname> <given-names>M.</given-names></name> <name><surname>Kotarba</surname> <given-names>A.</given-names></name></person-group> (<year>2020</year>). <article-title>Recent progress on parylene C polymer for biomedical applications: A review</article-title>. <source>Prog. Org. Coat.</source> <volume>140</volume>:<fpage>105493</fpage>. doi: <pub-id pub-id-type="doi">10.1016/j.porgcoat.2019.105493</pub-id></citation>
</ref>
<ref id="ref2002">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Guo</surname> <given-names>B.</given-names></name> <name><surname>Fan</surname> <given-names>Y.</given-names></name> <name><surname>Wang</surname> <given-names>M.</given-names></name> <name><surname>Cheng</surname> <given-names>Y.</given-names></name> <name><surname>Ji</surname> <given-names>B.</given-names></name> <name><surname>Chen</surname> <given-names>Y.</given-names></name> <etal/></person-group> (<year>2021</year>). <article-title>Flexible neural probes with electrochemical modified microelectrodes for artifact-free optogenetic applications</article-title>. <source>Int. J. Mol. Sci.</source> <volume>22</volume>.</citation>
</ref>
<ref id="ref33">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gwon</surname> <given-names>G.</given-names></name> <name><surname>Choi</surname> <given-names>H.</given-names></name> <name><surname>Bae</surname> <given-names>J.</given-names></name> <name><surname>Zulkifli</surname> <given-names>N. A. B.</given-names></name> <name><surname>Jeong</surname> <given-names>W.</given-names></name> <name><surname>Yoo</surname> <given-names>S.</given-names></name> <etal/></person-group>. (<year>2022</year>). <article-title>An all-nanofiber-based substrate-less, extremely conformal, and breathable organic field effect transistor for biomedical applications</article-title>. <source>Adv. Funct. Mater.</source> <volume>32</volume>:<fpage>2204645</fpage>. doi: <pub-id pub-id-type="doi">10.1002/adfm.202204645</pub-id></citation>
</ref>
<ref id="ref34">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>He</surname> <given-names>E.</given-names></name> <name><surname>Xu</surname> <given-names>S.</given-names></name> <name><surname>Dai</surname> <given-names>Y.</given-names></name> <name><surname>Wang</surname> <given-names>Y.</given-names></name> <name><surname>Xiao</surname> <given-names>G.</given-names></name> <name><surname>Xie</surname> <given-names>J.</given-names></name> <etal/></person-group>. (<year>2021</year>). <article-title>SWCNTs/PEDOT:PSS-modified microelectrode arrays for dual-mode detection of electrophysiological signals and dopamine concentration in the striatum under isoflurane anesthesia</article-title>. <source>ACS Sens.</source> <volume>6</volume>, <fpage>3377</fpage>&#x2013;<lpage>3386</lpage>. doi: <pub-id pub-id-type="doi">10.1021/acssensors.1c01241</pub-id>, PMID: <pub-id pub-id-type="pmid">34410704</pub-id></citation>
</ref>
<ref id="ref35">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hempel</surname> <given-names>F.</given-names></name> <name><surname>Law</surname> <given-names>J. K. Y.</given-names></name> <name><surname>Nguyen</surname> <given-names>T. C.</given-names></name> <name><surname>Munief</surname> <given-names>W.</given-names></name> <name><surname>Lu</surname> <given-names>X. L.</given-names></name> <name><surname>Pachauri</surname> <given-names>V.</given-names></name> <etal/></person-group>. (<year>2017</year>). <article-title>PEDOT:PSS organic electrochemical transistor arrays for extracellular electrophysiological sensing of cardiac cells</article-title>. <source>Biosens. Bioelectron.</source> <volume>93</volume>, <fpage>132</fpage>&#x2013;<lpage>138</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.bios.2016.09.047</pub-id>, PMID: <pub-id pub-id-type="pmid">27666366</pub-id></citation>
</ref>
<ref id="ref36">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hong</surname> <given-names>W.</given-names></name> <name><surname>Lee</surname> <given-names>J. W.</given-names></name> <name><surname>Kim</surname> <given-names>D.</given-names></name> <name><surname>Hwang</surname> <given-names>Y.</given-names></name> <name><surname>Lee</surname> <given-names>J.</given-names></name> <name><surname>Kim</surname> <given-names>J.</given-names></name> <etal/></person-group>. (<year>2022</year>). <article-title>Ultrathin gold microelectrode Array using polyelectrolyte multilayers for flexible and transparent electro-optical neural interfaces</article-title>. <source>Adv. Funct. Mater.</source> <volume>32</volume>:<fpage>2106493</fpage>. doi: <pub-id pub-id-type="doi">10.1002/adfm.202106493</pub-id></citation>
</ref>
<ref id="ref37">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hwang</surname> <given-names>H.</given-names></name> <name><surname>Kong</surname> <given-names>M.</given-names></name> <name><surname>Kim</surname> <given-names>K.</given-names></name> <name><surname>Park</surname> <given-names>D.</given-names></name> <name><surname>Lee</surname> <given-names>S.</given-names></name> <name><surname>Park</surname> <given-names>S.</given-names></name> <etal/></person-group>. (<year>2021</year>). <article-title>Stretchable anisotropic conductive film (S-ACF) for electrical interfacing in high-resolution stretchable circuits</article-title>. <source>Sci. Adv.</source> <volume>7</volume>:<fpage>eabh0171</fpage>. doi: <pub-id pub-id-type="doi">10.1126/sciadv.abh0171</pub-id>, PMID: <pub-id pub-id-type="pmid">34362737</pub-id></citation>
</ref>
<ref id="ref38">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jang</surname> <given-names>H.</given-names></name> <name><surname>Sel</surname> <given-names>K.</given-names></name> <name><surname>Kim</surname> <given-names>E.</given-names></name> <name><surname>Kim</surname> <given-names>S.</given-names></name> <name><surname>Yang</surname> <given-names>X.</given-names></name> <name><surname>Kang</surname> <given-names>S.</given-names></name> <etal/></person-group>. (<year>2022</year>). <article-title>Graphene e-tattoos for unobstructive ambulatory electrodermal activity sensing on the palm enabled by heterogeneous serpentine ribbons</article-title>. <source>Nat. Commun.</source> <volume>13</volume>:<fpage>6604</fpage>. doi: <pub-id pub-id-type="doi">10.1038/s41467-022-34406-2</pub-id>, PMID: <pub-id pub-id-type="pmid">36329038</pub-id></citation>
</ref>
<ref id="ref39">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Janjua</surname> <given-names>T. A. M.</given-names></name> <name><surname>Nielsen</surname> <given-names>T. G. N.</given-names></name> <name><surname>Andreis</surname> <given-names>F. R.</given-names></name> <name><surname>Meijs</surname> <given-names>S.</given-names></name> <name><surname>Jensen</surname> <given-names>W.</given-names></name></person-group> (<year>2021</year>). <article-title>The effect of peripheral high-frequency electrical stimulation on the primary somatosensory cortex in pigs</article-title>. <source>IBRO Neurosci. Rep.</source> <volume>11</volume>, <fpage>112</fpage>&#x2013;<lpage>118</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.ibneur.2021.08.004</pub-id>, PMID: <pub-id pub-id-type="pmid">34541572</pub-id></citation>
</ref>
<ref id="ref40">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ji</surname> <given-names>B.</given-names></name> <name><surname>Ge</surname> <given-names>C.</given-names></name> <name><surname>Guo</surname> <given-names>Z.</given-names></name> <name><surname>Wang</surname> <given-names>L.</given-names></name> <name><surname>Wang</surname> <given-names>M.</given-names></name> <name><surname>Xie</surname> <given-names>Z.</given-names></name> <etal/></person-group>. (<year>2020a</year>). <article-title>Flexible and stretchable opto-electric neural interface for low-noise electrocorticogram recordings and neuromodulation <italic>in vivo</italic></article-title>. <source>Biosens. Bioelectron.</source> <volume>153</volume>:<fpage>112009</fpage>. doi: <pub-id pub-id-type="doi">10.1016/j.bios.2020.112009</pub-id>, PMID: <pub-id pub-id-type="pmid">31989934</pub-id></citation>
</ref>
<ref id="ref41">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ji</surname> <given-names>B.</given-names></name> <name><surname>Xie</surname> <given-names>Z.</given-names></name> <name><surname>Hong</surname> <given-names>W.</given-names></name> <name><surname>Jiang</surname> <given-names>C.</given-names></name> <name><surname>Guo</surname> <given-names>Z.</given-names></name> <name><surname>Wang</surname> <given-names>L.</given-names></name> <etal/></person-group>. (<year>2020b</year>). <article-title>Stretchable Parylene-C electrodes enabled by serpentine structures on arbitrary elastomers by silicone rubber adhesive</article-title>. <source>J. Mater.</source> <volume>6</volume>, <fpage>330</fpage>&#x2013;<lpage>338</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.jmat.2019.11.006</pub-id></citation>
</ref>
<ref id="ref42">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Johnson</surname> <given-names>L. A.</given-names></name> <name><surname>Nebeck</surname> <given-names>S. D.</given-names></name> <name><surname>Muralidharan</surname> <given-names>A.</given-names></name> <name><surname>Johnson</surname> <given-names>M. D.</given-names></name> <name><surname>Baker</surname> <given-names>K. B.</given-names></name> <name><surname>Vitek</surname> <given-names>J. L.</given-names></name></person-group> (<year>2016</year>). <article-title>Closed-loop deep brain stimulation effects on parkinsonian motor symptoms in a non-human primate&#x2013;is beta enough?</article-title> <source>Brain Stimul.</source> <volume>9</volume>, <fpage>892</fpage>&#x2013;<lpage>896</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.brs.2016.06.051</pub-id>, PMID: <pub-id pub-id-type="pmid">27401045</pub-id></citation>
</ref>
<ref id="ref43">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kang</surname> <given-names>M.</given-names></name> <name><surname>Jeong</surname> <given-names>H.</given-names></name> <name><surname>Park</surname> <given-names>S.-W.</given-names></name> <name><surname>Hong</surname> <given-names>J.</given-names></name> <name><surname>Lee</surname> <given-names>H.</given-names></name> <name><surname>Chae</surname> <given-names>Y.</given-names></name> <etal/></person-group>. (<year>2022</year>). <article-title>Wireless graphene-based thermal patch for obtaining temperature distribution and performing thermography</article-title>. <source>Sci. Adv.</source> <volume>8</volume>:<fpage>eabm6693</fpage>. doi: <pub-id pub-id-type="doi">10.1126/sciadv.abm6693</pub-id>, PMID: <pub-id pub-id-type="pmid">35417247</pub-id></citation>
</ref>
<ref id="ref44">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Karumbaiah</surname> <given-names>L.</given-names></name> <name><surname>Norman</surname> <given-names>S. E.</given-names></name> <name><surname>Rajan</surname> <given-names>N. B.</given-names></name> <name><surname>Anand</surname> <given-names>S.</given-names></name> <name><surname>Saxena</surname> <given-names>T.</given-names></name> <name><surname>Betancur</surname> <given-names>M.</given-names></name> <etal/></person-group>. (<year>2012</year>). <article-title>The upregulation of specific interleukin (IL) receptor antagonists and paradoxical enhancement of neuronal apoptosis due to electrode induced strain and brain micromotion</article-title>. <source>Biomaterials</source> <volume>33</volume>, <fpage>5983</fpage>&#x2013;<lpage>5996</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.biomaterials.2012.05.021</pub-id>, PMID: <pub-id pub-id-type="pmid">22681976</pub-id></citation>
</ref>
<ref id="ref2004">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kauth</surname> <given-names>A.</given-names></name> <name><surname>Mildner</surname> <given-names>A.-K.</given-names></name> <name><surname>Hegel</surname> <given-names>L.</given-names></name> <name><surname>Wegener</surname> <given-names>J.</given-names></name> <name><surname>Ingebrandt</surname> <given-names>S.</given-names></name></person-group> (<year>2024</year>). <article-title>Development of Specialized Microelectrode Arrays with Local Electroporation Functionality</article-title>. <source>Annal. Biomed Eng.</source> <volume>52</volume>, <fpage>12</fpage>&#x2013;<lpage>21</lpage>.</citation>
</ref>
<ref id="ref45">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kim</surname> <given-names>Y.</given-names></name> <name><surname>Alimperti</surname> <given-names>S.</given-names></name> <name><surname>Choi</surname> <given-names>P.</given-names></name> <name><surname>Noh</surname> <given-names>M.</given-names></name></person-group> (<year>2022</year>). <article-title>An inkjet printed flexible Electrocorticography (ECoG) microelectrode Array on a thin Parylene-C film</article-title>. <source>Sensors</source> <volume>22</volume>:<fpage>1277</fpage>. doi: <pub-id pub-id-type="doi">10.3390/s22031277</pub-id>, PMID: <pub-id pub-id-type="pmid">35162023</pub-id></citation>
</ref>
<ref id="ref46">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kim</surname> <given-names>S. J.</given-names></name> <name><surname>Lee</surname> <given-names>D. S.</given-names></name> <name><surname>Kim</surname> <given-names>I. G.</given-names></name> <name><surname>Sohn</surname> <given-names>D. W.</given-names></name> <name><surname>Park</surname> <given-names>J. Y.</given-names></name> <name><surname>Choi</surname> <given-names>B. K.</given-names></name> <etal/></person-group>. (<year>2012</year>). <article-title>Evaluation of the biocompatibility of a coating material for an implantable bladder volume sensor</article-title>. <source>Kaohsiung J. Med. Sci.</source> <volume>28</volume>, <fpage>123</fpage>&#x2013;<lpage>129</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.kjms.2011.10.016</pub-id>, PMID: <pub-id pub-id-type="pmid">22385604</pub-id></citation>
</ref>
<ref id="ref47">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kim</surname> <given-names>M. K.</given-names></name> <name><surname>Leong</surname> <given-names>J. C.</given-names></name> <name><surname>Jo</surname> <given-names>Y.</given-names></name> <name><surname>Kook</surname> <given-names>G.</given-names></name> <name><surname>Lee</surname> <given-names>H. J.</given-names></name></person-group> (<year>2023</year>). <article-title>Multimodal neural probes with small form factor based on dual-side fabrication</article-title>. <source>Adv. Mater. Technol.</source> <volume>8</volume>:<fpage>2200692</fpage>. doi: <pub-id pub-id-type="doi">10.1002/admt.202200692</pub-id></citation>
</ref>
<ref id="ref48">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kolaya</surname> <given-names>E.</given-names></name> <name><surname>Firestein</surname> <given-names>B. L.</given-names></name></person-group> (<year>2021</year>). <article-title>Deep brain stimulation: challenges at the tissue-electrode interface and current solutions</article-title>. <source>Biotechnol. Prog.</source> <volume>37</volume>:<fpage>e3179</fpage>. doi: <pub-id pub-id-type="doi">10.1002/btpr.3179</pub-id>, PMID: <pub-id pub-id-type="pmid">34056871</pub-id></citation>
</ref>
<ref id="ref2008">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kozai</surname> <given-names>T. D.</given-names></name> <name><surname>Jaquins-Gerstl</surname> <given-names>A. S.</given-names></name> <name><surname>Vazquez</surname> <given-names>A. L.</given-names></name> <name><surname>Michael</surname> <given-names>A. C.</given-names></name> <name><surname>Cui</surname> <given-names>X. T.</given-names></name></person-group> (<year>2015</year>). <article-title>Brain tissue responses to neural implants impact signal sensitivity and intervention strategies</article-title>. <source>ACS Chem. Neurosci.</source> <volume>6</volume>, <fpage>48</fpage>&#x2013;<lpage>67</lpage>.</citation>
</ref>
<ref id="ref49">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kshirsagar</surname> <given-names>P.</given-names></name> <name><surname>Dickreuter</surname> <given-names>S.</given-names></name> <name><surname>Mierzejewski</surname> <given-names>M.</given-names></name> <name><surname>Burkhardt</surname> <given-names>C. J.</given-names></name> <name><surname>Chass&#x00E9;</surname> <given-names>T.</given-names></name> <name><surname>Fleischer</surname> <given-names>M.</given-names></name> <etal/></person-group>. (<year>2019</year>). <article-title>Transparent graphene/PEDOT: PSS microelectrodes for electro-and optophysiology</article-title>. <source>Adv. Mater. Technol.</source> <volume>4</volume>:<fpage>1800318</fpage>. doi: <pub-id pub-id-type="doi">10.1002/admt.201800318</pub-id></citation>
</ref>
<ref id="ref50">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Le Floch</surname> <given-names>P.</given-names></name> <name><surname>Li</surname> <given-names>Q.</given-names></name> <name><surname>Lin</surname> <given-names>Z.</given-names></name> <name><surname>Zhao</surname> <given-names>S.</given-names></name> <name><surname>Liu</surname> <given-names>R.</given-names></name> <name><surname>Tasnim</surname> <given-names>K.</given-names></name> <etal/></person-group>. (<year>2022</year>). <article-title>Stretchable mesh Nanoelectronics for 3D single-cell chronic electrophysiology from developing brain organoids</article-title>. <source>Adv. Mater.</source> <volume>34</volume>:<fpage>2106829</fpage>. doi: <pub-id pub-id-type="doi">10.1002/adma.202106829</pub-id></citation>
</ref>
<ref id="ref51">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lee</surname> <given-names>H.-S.</given-names></name> <name><surname>Eom</surname> <given-names>K.</given-names></name> <name><surname>Park</surname> <given-names>M.</given-names></name> <name><surname>Ku</surname> <given-names>S.-B.</given-names></name> <name><surname>Lee</surname> <given-names>K.</given-names></name> <name><surname>Lee</surname> <given-names>H.-M.</given-names></name></person-group> (<year>2022</year>). <article-title>High-density neural recording system design</article-title>. <source>Biomed. Eng. Lett.</source> <volume>12</volume>, <fpage>251</fpage>&#x2013;<lpage>261</lpage>. doi: <pub-id pub-id-type="doi">10.1007/s13534-022-00233-z</pub-id>, PMID: <pub-id pub-id-type="pmid">35892035</pub-id></citation>
</ref>
<ref id="ref52">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Li</surname> <given-names>G.</given-names></name> <name><surname>Huang</surname> <given-names>K.</given-names></name> <name><surname>Deng</surname> <given-names>J.</given-names></name> <name><surname>Guo</surname> <given-names>M.</given-names></name> <name><surname>Cai</surname> <given-names>M.</given-names></name> <name><surname>Zhang</surname> <given-names>Y.</given-names></name> <etal/></person-group>. (<year>2022</year>). <article-title>Highly conducting and stretchable double-network hydrogel for soft bioelectronics</article-title>. <source>Adv. Mater.</source> <volume>34</volume>:<fpage>2200261</fpage>. doi: <pub-id pub-id-type="doi">10.1002/adma.202200261</pub-id></citation>
</ref>
<ref id="ref53">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ling</surname> <given-names>W.</given-names></name> <name><surname>Yu</surname> <given-names>J.</given-names></name> <name><surname>Ma</surname> <given-names>N.</given-names></name> <name><surname>Li</surname> <given-names>Y.</given-names></name> <name><surname>Wu</surname> <given-names>Z.</given-names></name> <name><surname>Liang</surname> <given-names>R.</given-names></name> <etal/></person-group>. (<year>2020</year>). <article-title>Flexible electronics and materials for synchronized stimulation and monitoring in multi-encephalic regions</article-title>. <source>Adv. Funct. Mater.</source> <volume>30</volume>:<fpage>2002644</fpage>. doi: <pub-id pub-id-type="doi">10.1002/adfm.202002644</pub-id></citation>
</ref>
<ref id="ref54">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Little</surname> <given-names>S.</given-names></name> <name><surname>Tripoliti</surname> <given-names>E.</given-names></name> <name><surname>Beudel</surname> <given-names>M.</given-names></name> <name><surname>Pogosyan</surname> <given-names>A.</given-names></name> <name><surname>Cagnan</surname> <given-names>H.</given-names></name> <name><surname>Herz</surname> <given-names>D.</given-names></name> <etal/></person-group>. (<year>2016</year>). <article-title>Adaptive deep brain stimulation for Parkinson's disease demonstrates reduced speech side effects compared to conventional stimulation in the acute setting</article-title>. <source>J. Neurol. Neurosurg. Psychiatry</source> <volume>87</volume>, <fpage>1388</fpage>&#x2013;<lpage>1389</lpage>. doi: <pub-id pub-id-type="doi">10.1136/jnnp-2016-313518</pub-id>, PMID: <pub-id pub-id-type="pmid">27530809</pub-id></citation>
</ref>
<ref id="ref55">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Liu</surname> <given-names>M.</given-names></name> <name><surname>Ushiba</surname> <given-names>J.</given-names></name></person-group> (<year>2022</year>). <article-title>Brain&#x2013;machine Interface (BMI)-based neurorehabilitation for post-stroke upper limb paralysis</article-title>. <source>Keio J. Med.</source> <volume>71</volume>, <fpage>82</fpage>&#x2013;<lpage>92</lpage>. doi: <pub-id pub-id-type="doi">10.2302/kjm.2022-0002-OA</pub-id>, PMID: <pub-id pub-id-type="pmid">35718470</pub-id></citation>
</ref>
<ref id="ref655">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Liu</surname> <given-names>X.</given-names></name> <name><surname>Sanchez</surname> <given-names>S.</given-names></name> <name><surname>Gong</surname> <given-names>Y.</given-names></name> <name><surname>Jiang</surname> <given-names>Z.</given-names></name> <name><surname>Stevens</surname> <given-names>T.</given-names></name> <name><surname>Banan</surname> <given-names>H.</given-names></name> <etal/></person-group> (<year>n.d.</year>). &#x201C;<article-title>Flexible Dual-Sided Polymer Microelectrode Array for Neurophysiological Recordings from an Insect Brain</article-title>&#x201D;, in: <source>2024 IEEE 37th International Conference on Micro Electro Mechanical Systems (MEMS),</source> 247&#x2013;250.</citation>
</ref>
<ref id="ref56">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Luo</surname> <given-names>Y.</given-names></name> <name><surname>Abidian</surname> <given-names>M. R.</given-names></name> <name><surname>Ahn</surname> <given-names>J.-H.</given-names></name> <name><surname>Akinwande</surname> <given-names>D.</given-names></name> <name><surname>Andrews</surname> <given-names>A. M.</given-names></name> <name><surname>Antonietti</surname> <given-names>M.</given-names></name> <etal/></person-group>. (<year>2023</year>). <article-title>Technology roadmap for flexible sensors</article-title>. <source>ACS Nano</source> <volume>17</volume>, <fpage>5211</fpage>&#x2013;<lpage>5295</lpage>. doi: <pub-id pub-id-type="doi">10.1021/acsnano.2c12606</pub-id>, PMID: <pub-id pub-id-type="pmid">36892156</pub-id></citation>
</ref>
<ref id="ref57">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mandelli</surname> <given-names>J. S.</given-names></name> <name><surname>Koepp</surname> <given-names>J.</given-names></name> <name><surname>Hama</surname> <given-names>A.</given-names></name> <name><surname>Sanaur</surname> <given-names>S.</given-names></name> <name><surname>Rae</surname> <given-names>G. A.</given-names></name> <name><surname>Rambo</surname> <given-names>C. R.</given-names></name></person-group> (<year>2021</year>). <article-title>Cell viability and cytotoxicity of inkjet-printed flexible organic electrodes on parylene C</article-title>. <source>Biomed. Microdevices</source> <volume>23</volume>, <fpage>1</fpage>&#x2013;<lpage>12</lpage>. doi: <pub-id pub-id-type="doi">10.1007/s10544-020-00542-z</pub-id></citation>
</ref>
<ref id="ref2005">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Max</surname> <given-names>E.</given-names></name> <name><surname>Thoralf</surname> <given-names>H.</given-names></name> <name><surname>Marius</surname> <given-names>W.</given-names></name> <name><surname>Annette</surname> <given-names>M.</given-names></name> <name><surname>Linda</surname> <given-names>R.</given-names></name> <name><surname>G&#x00FC;nther</surname> <given-names>Z.</given-names></name> <etal/></person-group> (<year>2022</year>). <article-title>An optoelectronic neural interface approach for precise superposition of optical and electrical stimulation in flexible array structures</article-title>. <source>Biosen. Bioelect.</source> <volume>205</volume>, <fpage>114090</fpage>.</citation>
</ref>
<ref id="ref58">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mcdonald</surname> <given-names>M.</given-names></name> <name><surname>Sebinger</surname> <given-names>D.</given-names></name> <name><surname>Brauns</surname> <given-names>L.</given-names></name> <name><surname>Gonzalez-Cano</surname> <given-names>L.</given-names></name> <name><surname>Menuchin-Lasowski</surname> <given-names>Y.</given-names></name> <name><surname>Mierzejewski</surname> <given-names>M.</given-names></name> <etal/></person-group>. (<year>2023</year>). <article-title>A mesh microelectrode array for non-invasive electrophysiology within neural organoids</article-title>. <source>Biosens. Bioelectron.</source> <volume>228</volume>:<fpage>115223</fpage>. doi: <pub-id pub-id-type="doi">10.1016/j.bios.2023.115223</pub-id>, PMID: <pub-id pub-id-type="pmid">36931193</pub-id></citation>
</ref>
<ref id="ref59">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mcnamara</surname> <given-names>M.</given-names></name> <name><surname>Ersoz</surname> <given-names>A.</given-names></name> <name><surname>Han</surname> <given-names>M.</given-names></name></person-group> (<year>2021</year>). <article-title>A diagnostic circuit for crosstalk detection in microelectrode arrays</article-title>. <source>Int. IEEE EMBS Conf. Neural Eng.</source> <volume>2021</volume>, <fpage>544</fpage>&#x2013;<lpage>547</lpage>. doi: <pub-id pub-id-type="doi">10.1109/ner49283.2021.9441164</pub-id>, PMID: <pub-id pub-id-type="pmid">34925703</pub-id></citation>
</ref>
<ref id="ref60">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Merrill</surname> <given-names>D. R.</given-names></name> <name><surname>Tresco</surname> <given-names>P. A.</given-names></name></person-group> (<year>2005</year>). <article-title>Impedance characterization of microarray recording electrodes in vitro</article-title>. <source>I.E.E.E. Trans. Biomed. Eng.</source> <volume>52</volume>, <fpage>1960</fpage>&#x2013;<lpage>1965</lpage>. doi: <pub-id pub-id-type="doi">10.1109/TBME.2005.856245</pub-id>, PMID: <pub-id pub-id-type="pmid">16285400</pub-id></citation>
</ref>
<ref id="ref61">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Miccoli</surname> <given-names>B.</given-names></name> <name><surname>Lopez</surname> <given-names>C. M.</given-names></name> <name><surname>Goikoetxea</surname> <given-names>E.</given-names></name> <name><surname>Putzeys</surname> <given-names>J.</given-names></name> <name><surname>Sekeri</surname> <given-names>M.</given-names></name> <name><surname>Krylychkina</surname> <given-names>O.</given-names></name> <etal/></person-group>. (<year>2019</year>). <article-title>High-density electrical recording and impedance imaging with a multi-modal CMOS multi-electrode array chip</article-title>. <source>Front. Neurosci.</source> <volume>13</volume>:<fpage>641</fpage>. doi: <pub-id pub-id-type="doi">10.3389/fnins.2019.00641</pub-id>, PMID: <pub-id pub-id-type="pmid">31293372</pub-id></citation>
</ref>
<ref id="ref62">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Miyamoto</surname> <given-names>A.</given-names></name> <name><surname>Kawasaki</surname> <given-names>H.</given-names></name> <name><surname>Lee</surname> <given-names>S.</given-names></name> <name><surname>Yokota</surname> <given-names>T.</given-names></name> <name><surname>Amagai</surname> <given-names>M.</given-names></name> <name><surname>Someya</surname> <given-names>T.</given-names></name></person-group> (<year>2022</year>). <article-title>Highly precise, continuous, Long-term monitoring of skin electrical resistance by Nanomesh electrodes</article-title>. <source>Adv. Healthc. Mater.</source> <volume>11</volume>:<fpage>e2102425</fpage>. doi: <pub-id pub-id-type="doi">10.1002/adhm.202102425</pub-id>, PMID: <pub-id pub-id-type="pmid">34994099</pub-id></citation>
</ref>
<ref id="ref63">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mohammed</surname> <given-names>M.</given-names></name> <name><surname>Ivica</surname> <given-names>N.</given-names></name> <name><surname>Bjartmarz</surname> <given-names>H.</given-names></name> <name><surname>Thorbergsson</surname> <given-names>P. T.</given-names></name> <name><surname>Pettersson</surname> <given-names>L. M. E.</given-names></name> <name><surname>Thelin</surname> <given-names>J.</given-names></name> <etal/></person-group>. (<year>2022</year>). <article-title>Microelectrode clusters enable therapeutic deep brain stimulation without noticeable side-effects in a rodent model of Parkinson's disease</article-title>. <source>J. Neurosci. Methods</source> <volume>365</volume>:<fpage>109399</fpage>. doi: <pub-id pub-id-type="doi">10.1016/j.jneumeth.2021.109399</pub-id></citation>
</ref>
<ref id="ref64">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Musk</surname> <given-names>E.</given-names></name>
</person-group> (<year>2019</year>). <article-title>An integrated brain-machine Interface platform with thousands of channels</article-title>. <source>J. Med. Internet Res.</source> <volume>21</volume>:<fpage>e16194</fpage>. doi: <pub-id pub-id-type="doi">10.2196/16194</pub-id>, PMID: <pub-id pub-id-type="pmid">31642810</pub-id></citation>
</ref>
<ref id="ref65">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Najafi</surname> <given-names>K.</given-names></name> <name><surname>Ji</surname> <given-names>J.</given-names></name> <name><surname>Wise</surname> <given-names>K.</given-names></name></person-group> (<year>1990</year>). <article-title>Scaling limitations of silicon multichannel recording probes</article-title>. <source>IEEE Trans. Biomed. Eng.</source> <volume>37</volume>, <fpage>1</fpage>&#x2013;<lpage>11</lpage>. doi: <pub-id pub-id-type="doi">10.1109/10.43605</pub-id>, PMID: <pub-id pub-id-type="pmid">2303265</pub-id></citation>
</ref>
<ref id="ref66">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Nam</surname> <given-names>Y.</given-names></name>
</person-group> (<year>2021</year>). <article-title>State-of-the-art Technology on MEAs for interfacing live neurons</article-title>. <source>Handb. Neuroeng.</source>, <fpage>1</fpage>&#x2013;<lpage>41</lpage>. doi: <pub-id pub-id-type="doi">10.1007/978-981-15-2848-4_8-2</pub-id></citation>
</ref>
<ref id="ref67">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Naughton</surname> <given-names>J.</given-names></name> <name><surname>Varela</surname> <given-names>J.</given-names></name> <name><surname>Connolly</surname> <given-names>T.</given-names></name> <name><surname>Shepard</surname> <given-names>S.</given-names></name> <name><surname>Dodge</surname> <given-names>T.</given-names></name> <name><surname>Kempa</surname> <given-names>K.</given-names></name> <etal/></person-group>. (<year>2022</year>). <article-title>Suppression of crosstalk in multielectrode arrays with local shielding</article-title>. <source>Front. Nanotechnol.</source> <volume>4</volume>:<fpage>948337</fpage>. doi: <pub-id pub-id-type="doi">10.3389/fnano.2022.948337</pub-id></citation>
</ref>
<ref id="ref68">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Niederhoffer</surname> <given-names>T.</given-names></name> <name><surname>Vanhoestenberghe</surname> <given-names>A.</given-names></name> <name><surname>Lancashire</surname> <given-names>H. T.</given-names></name></person-group> (<year>2023</year>). <article-title>Methods of poly(3,4)-ethylenedioxithiophene (PEDOT) electrodeposition on metal electrodes for neural stimulation and recording</article-title>. <source>J. Neural Eng.</source> <volume>20</volume>:<fpage>011002</fpage>. doi: <pub-id pub-id-type="doi">10.1088/1741-2552/acb084</pub-id></citation>
</ref>
<ref id="ref69">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Oldroyd</surname> <given-names>P.</given-names></name> <name><surname>Malliaras</surname> <given-names>G. G.</given-names></name></person-group> (<year>2022</year>). <article-title>Achieving long-term stability of thin-film electrodes for neurostimulation</article-title>. <source>Acta Biomater.</source> <volume>139</volume>, <fpage>65</fpage>&#x2013;<lpage>81</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.actbio.2021.05.004</pub-id>, PMID: <pub-id pub-id-type="pmid">34020055</pub-id></citation>
</ref>
<ref id="ref70">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Olsen</surname> <given-names>L. K.</given-names></name> <name><surname>Moore</surname> <given-names>R. J.</given-names></name> <name><surname>Bechmann</surname> <given-names>N. A.</given-names></name> <name><surname>Ethridge</surname> <given-names>V. T.</given-names></name> <name><surname>Gargas</surname> <given-names>N. M.</given-names></name> <name><surname>Cunningham</surname> <given-names>S. D.</given-names></name> <etal/></person-group>. (<year>2022</year>). <article-title>Vagus nerve stimulation-induced cognitive enhancement: hippocampal neuroplasticity in healthy male rats</article-title>. <source>Brain Stimul.</source> <volume>15</volume>, <fpage>1101</fpage>&#x2013;<lpage>1110</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.brs.2022.08.001</pub-id>, PMID: <pub-id pub-id-type="pmid">35970317</pub-id></citation>
</ref>
<ref id="ref71">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Otte</surname> <given-names>E.</given-names></name> <name><surname>Vlachos</surname> <given-names>A.</given-names></name> <name><surname>Asplund</surname> <given-names>M.</given-names></name></person-group> (<year>2022</year>). <article-title>Engineering strategies towards overcoming bleeding and glial scar formation around neural probes</article-title>. <source>Cell Tissue Res.</source> <volume>387</volume>, <fpage>461</fpage>&#x2013;<lpage>477</lpage>. doi: <pub-id pub-id-type="doi">10.1007/s00441-021-03567-9</pub-id>, PMID: <pub-id pub-id-type="pmid">35029757</pub-id></citation>
</ref>
<ref id="ref72">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ouyang</surname> <given-names>W.</given-names></name> <name><surname>Lu</surname> <given-names>W.</given-names></name> <name><surname>Zhang</surname> <given-names>Y.</given-names></name> <name><surname>Liu</surname> <given-names>Y.</given-names></name> <name><surname>Kim</surname> <given-names>J. U.</given-names></name> <name><surname>Shen</surname> <given-names>H.</given-names></name> <etal/></person-group>. (<year>2023</year>). <article-title>A wireless and battery-less implant for multimodal closed-loop neuromodulation in small animals</article-title>. <source>Nat. Biomed. Eng.</source> <volume>7</volume>, <fpage>1252</fpage>&#x2013;<lpage>1269</lpage>. doi: <pub-id pub-id-type="doi">10.1038/s41551-023-01029-x</pub-id></citation>
</ref>
<ref id="ref73">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Park</surname> <given-names>S.-W.</given-names></name> <name><surname>Kim</surname> <given-names>J.</given-names></name> <name><surname>Kang</surname> <given-names>M.</given-names></name> <name><surname>Lee</surname> <given-names>W.</given-names></name> <name><surname>Park</surname> <given-names>B. S.</given-names></name> <name><surname>Kim</surname> <given-names>H.</given-names></name> <etal/></person-group>. (<year>2018</year>). <article-title>Epidural electrotherapy for epilepsy</article-title>. <source>Small</source> <volume>14</volume>:<fpage>e1801732</fpage>. doi: <pub-id pub-id-type="doi">10.1002/smll.201801732</pub-id>, PMID: <pub-id pub-id-type="pmid">29952144</pub-id></citation>
</ref>
<ref id="ref74">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Park</surname> <given-names>Y. J.</given-names></name> <name><surname>Sharma</surname> <given-names>B. K.</given-names></name> <name><surname>Shinde</surname> <given-names>S. M.</given-names></name> <name><surname>Kim</surname> <given-names>M.-S.</given-names></name> <name><surname>Jang</surname> <given-names>B.</given-names></name> <name><surname>Kim</surname> <given-names>J.-H.</given-names></name> <etal/></person-group>. (<year>2019</year>). <article-title>All MoS2-based large area, skin-attachable active-matrix tactile sensor</article-title>. <source>ACS Nano</source> <volume>13</volume>, <fpage>3023</fpage>&#x2013;<lpage>3030</lpage>. doi: <pub-id pub-id-type="doi">10.1021/acsnano.8b07995</pub-id>, PMID: <pub-id pub-id-type="pmid">30768896</pub-id></citation>
</ref>
<ref id="ref75">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Park</surname> <given-names>S.</given-names></name> <name><surname>Yuk</surname> <given-names>H.</given-names></name> <name><surname>Zhao</surname> <given-names>R.</given-names></name> <name><surname>Yim</surname> <given-names>Y. S.</given-names></name> <name><surname>Woldeghebriel</surname> <given-names>E. W.</given-names></name> <name><surname>Kang</surname> <given-names>J.</given-names></name> <etal/></person-group>. (<year>2021</year>). <article-title>Adaptive and multifunctional hydrogel hybrid probes for long-term sensing and modulation of neural activity</article-title>. <source>Nat. Commun.</source> <volume>12</volume>:<fpage>3435</fpage>. doi: <pub-id pub-id-type="doi">10.1038/s41467-021-23802-9</pub-id>, PMID: <pub-id pub-id-type="pmid">34103511</pub-id></citation>
</ref>
<ref id="ref76">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pimenta</surname> <given-names>S.</given-names></name> <name><surname>Rodrigues</surname> <given-names>J. A.</given-names></name> <name><surname>Machado</surname> <given-names>F.</given-names></name> <name><surname>Ribeiro</surname> <given-names>J. F.</given-names></name> <name><surname>Maciel</surname> <given-names>M. J.</given-names></name> <name><surname>Bondarchuk</surname> <given-names>O.</given-names></name> <etal/></person-group>. (<year>2021</year>). <article-title>Double-layer flexible neural probe with closely spaced electrodes for high-density in vivo brain recordings</article-title>. <source>Front. Neurosci.</source> <volume>15</volume>:<fpage>663174</fpage>. doi: <pub-id pub-id-type="doi">10.3389/fnins.2021.663174</pub-id>, PMID: <pub-id pub-id-type="pmid">34211364</pub-id></citation>
</ref>
<ref id="ref77">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Polanco</surname> <given-names>M.</given-names></name> <name><surname>Bawab</surname> <given-names>S.</given-names></name> <name><surname>Yoon</surname> <given-names>H.</given-names></name></person-group> (<year>2016</year>). <article-title>Computational assessment of neural probe and brain tissue interface under transient motion</article-title>. <source>Biosensors</source> <volume>6</volume>:<fpage>27</fpage>. doi: <pub-id pub-id-type="doi">10.3390/bios6020027</pub-id>, PMID: <pub-id pub-id-type="pmid">27322338</pub-id></citation>
</ref>
<ref id="ref78">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Polikov</surname> <given-names>V. S.</given-names></name> <name><surname>Tresco</surname> <given-names>P. A.</given-names></name> <name><surname>Reichert</surname> <given-names>W. M.</given-names></name></person-group> (<year>2005</year>). <article-title>Response of brain tissue to chronically implanted neural electrodes</article-title>. <source>J. Neurosci. Methods</source> <volume>148</volume>, <fpage>1</fpage>&#x2013;<lpage>18</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.jneumeth.2005.08.015</pub-id></citation>
</ref>
<ref id="ref79">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Prasad</surname> <given-names>A.</given-names></name> <name><surname>Sanchez</surname> <given-names>J. C.</given-names></name></person-group> (<year>2012</year>). <article-title>Quantifying long-term microelectrode array functionality using chronic in vivo impedance testing</article-title>. <source>J. Neural Eng.</source> <volume>9</volume>:<fpage>026028</fpage>. doi: <pub-id pub-id-type="doi">10.1088/1741-2560/9/2/026028</pub-id>, PMID: <pub-id pub-id-type="pmid">22442134</pub-id></citation>
</ref>
<ref id="ref80">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Qiang</surname> <given-names>Y.</given-names></name> <name><surname>Gu</surname> <given-names>W.</given-names></name> <name><surname>Liu</surname> <given-names>Z.</given-names></name> <name><surname>Liang</surname> <given-names>S.</given-names></name> <name><surname>Ryu</surname> <given-names>J. H.</given-names></name> <name><surname>Seo</surname> <given-names>K. J.</given-names></name> <etal/></person-group>. (<year>2021</year>). <article-title>Crosstalk in polymer microelectrode arrays</article-title>. <source>Nano Res.</source> <volume>14</volume>, <fpage>3240</fpage>&#x2013;<lpage>3247</lpage>. doi: <pub-id pub-id-type="doi">10.1007/s12274-021-3442-8</pub-id>, PMID: <pub-id pub-id-type="pmid">34394850</pub-id></citation>
</ref>
<ref id="ref81">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ramesh</surname> <given-names>V.</given-names></name> <name><surname>Stratmann</surname> <given-names>N.</given-names></name> <name><surname>Schaufler</surname> <given-names>V.</given-names></name> <name><surname>Angelov</surname> <given-names>S. D.</given-names></name> <name><surname>Nordhorn</surname> <given-names>I. D.</given-names></name> <name><surname>Heissler</surname> <given-names>H. E.</given-names></name> <etal/></person-group>. (<year>2022</year>). <article-title>Mechanical stability of Nano-coatings on clinically applicable electrodes, generated by electrophoretic deposition</article-title>. <source>Adv. Healthc. Mater.</source> <volume>11</volume>:<fpage>e2102637</fpage>. doi: <pub-id pub-id-type="doi">10.1002/adhm.202102637</pub-id>, PMID: <pub-id pub-id-type="pmid">36148583</pub-id></citation>
</ref>
<ref id="ref82">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Rao</surname> <given-names>L.</given-names></name> <name><surname>Zhou</surname> <given-names>H.</given-names></name> <name><surname>Li</surname> <given-names>T.</given-names></name> <name><surname>Li</surname> <given-names>C.</given-names></name> <name><surname>Duan</surname> <given-names>Y. Y.</given-names></name></person-group> (<year>2012</year>). <article-title>Polyethylene glycol-containing polyurethane hydrogel coatings for improving the biocompatibility of neural electrodes</article-title>. <source>Acta Biomater.</source> <volume>8</volume>, <fpage>2233</fpage>&#x2013;<lpage>2242</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.actbio.2012.03.001</pub-id></citation>
</ref>
<ref id="ref83">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Raviprakash</surname> <given-names>H.</given-names></name> <name><surname>Korostenskaja</surname> <given-names>M.</given-names></name> <name><surname>Castillo</surname> <given-names>E. M.</given-names></name> <name><surname>Lee</surname> <given-names>K. H.</given-names></name> <name><surname>Salinas</surname> <given-names>C. M.</given-names></name> <name><surname>Baumgartner</surname> <given-names>J.</given-names></name> <etal/></person-group>. (<year>2020</year>). <article-title>Deep learning provides exceptional accuracy to ECoG-based functional language mapping for epilepsy surgery</article-title>. <source>Front. Neurosci.</source> <volume>14</volume>:<fpage>409</fpage>. doi: <pub-id pub-id-type="doi">10.3389/fnins.2020.00409</pub-id>, PMID: <pub-id pub-id-type="pmid">32435182</pub-id></citation>
</ref>
<ref id="ref84">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Saleh</surname> <given-names>M. S.</given-names></name> <name><surname>Ritchie</surname> <given-names>S. M.</given-names></name> <name><surname>Nicholas</surname> <given-names>M. A.</given-names></name> <name><surname>Gordon</surname> <given-names>H. L.</given-names></name> <name><surname>Hu</surname> <given-names>C.</given-names></name> <name><surname>Jahan</surname> <given-names>S.</given-names></name> <etal/></person-group>. (<year>2022</year>). <article-title>CMU Array: A 3D nanoprinted, fully customizable high-density microelectrode array platform. Science</article-title>. <source>Advances</source> <volume>8</volume>:<fpage>eabj4853</fpage>. doi: <pub-id pub-id-type="doi">10.1126/sciadv.abj4853</pub-id></citation>
</ref>
<ref id="ref85">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Schander</surname> <given-names>A.</given-names></name> <name><surname>Gancz</surname> <given-names>J. M.</given-names></name> <name><surname>Tintelott</surname> <given-names>M.</given-names></name> <name><surname>Lang</surname> <given-names>W.</given-names></name></person-group> (<year>2021</year>). <article-title>Towards Long-term stable polyimide-based flexible electrical insulation for chronically implanted neural electrodes</article-title>. <source>Micromachines (Basel)</source> <volume>12</volume>:<fpage>12</fpage>. doi: <pub-id pub-id-type="doi">10.3390/mi12111279</pub-id></citation>
</ref>
<ref id="ref86">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Schiavone</surname> <given-names>G.</given-names></name> <name><surname>Fallegger</surname> <given-names>F.</given-names></name> <name><surname>Kang</surname> <given-names>X.</given-names></name> <name><surname>Barra</surname> <given-names>B.</given-names></name> <name><surname>Vachicouras</surname> <given-names>N.</given-names></name> <name><surname>Roussinova</surname> <given-names>E.</given-names></name> <etal/></person-group>. (<year>2020</year>). <article-title>Soft, implantable bioelectronic interfaces for translational research</article-title>. <source>Adv. Mater.</source> <volume>32</volume>:<fpage>e1906512</fpage>. doi: <pub-id pub-id-type="doi">10.1002/adma.201906512</pub-id>, PMID: <pub-id pub-id-type="pmid">32173913</pub-id></citation>
</ref>
<ref id="ref87">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Scholten</surname> <given-names>K.</given-names></name> <name><surname>Larson</surname> <given-names>C. E.</given-names></name> <name><surname>Xu</surname> <given-names>H.</given-names></name> <name><surname>Song</surname> <given-names>D.</given-names></name> <name><surname>Meng</surname> <given-names>E.</given-names></name></person-group> (<year>2020</year>). <article-title>A 512-channel multi-layer polymer-based neural probe Array</article-title>. <source>J. Microelectromech. Syst.</source> <volume>29</volume>, <fpage>1054</fpage>&#x2013;<lpage>1058</lpage>. doi: <pub-id pub-id-type="doi">10.1109/JMEMS.2020.2999550</pub-id>, PMID: <pub-id pub-id-type="pmid">33746477</pub-id></citation>
</ref>
<ref id="ref2007">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Seo</surname> <given-names>H. W.</given-names></name> <name><surname>Kim</surname> <given-names>N.</given-names></name> <name><surname>Kim</surname> <given-names>S.</given-names></name></person-group> (<year>2020</year>). <article-title>Fabrication of subretinal 3d microelectrodes with hexagonal arrangement</article-title>. <source>Micromac.</source> <volume>11</volume>.</citation>
</ref>
<ref id="ref88">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Seok</surname> <given-names>S.</given-names></name>
</person-group> (<year>2021</year>). <article-title>Polymer-based biocompatible packaging for implantable devices: packaging method, materials, and reliability simulation</article-title>. <source>Micromachines (Basel).</source> <volume>12</volume>:<fpage>1020</fpage>.</citation>
</ref>
<ref id="ref89">
<citation citation-type="other"><person-group person-group-type="author"><name><surname>Shah</surname> <given-names>K.G.</given-names></name> <name><surname>Chen</surname> <given-names>S.</given-names></name> <name><surname>Felix</surname> <given-names>S.H.</given-names></name> <name><surname>Pannu</surname> <given-names>S.S.</given-names></name> <name><surname>Patra</surname> <given-names>S.</given-names></name> <name><surname>Tolosa</surname> <given-names>V.</given-names></name> <etal/></person-group>. (<year>2022</year>). Cylindrical microelectrode array for neural stimulation and recording.</citation>
</ref>
<ref id="ref90">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sharafkhani</surname> <given-names>N.</given-names></name> <name><surname>Kouzani</surname> <given-names>A. Z.</given-names></name> <name><surname>Adams</surname> <given-names>S. D.</given-names></name> <name><surname>Long</surname> <given-names>J. M.</given-names></name> <name><surname>Lissorgues</surname> <given-names>G.</given-names></name> <name><surname>Rousseau</surname> <given-names>L.</given-names></name> <etal/></person-group>. (<year>2022</year>). <article-title>Neural tissue-microelectrode interaction: brain micromotion, electrical impedance, and flexible microelectrode insertion</article-title>. <source>J. Neurosci. Methods</source> <volume>365</volume>:<fpage>109388</fpage>. doi: <pub-id pub-id-type="doi">10.1016/j.jneumeth.2021.109388</pub-id>, PMID: <pub-id pub-id-type="pmid">34678387</pub-id></citation>
</ref>
<ref id="ref91">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Shen</surname> <given-names>K.</given-names></name> <name><surname>Maharbiz</surname> <given-names>M. M.</given-names></name></person-group> (<year>2021</year>). <article-title>Ceramic packaging in neural implants</article-title>. <source>J. Neural Eng.</source> <volume>18</volume>:<fpage>abd683</fpage>. doi: <pub-id pub-id-type="doi">10.1088/1741-2552/abd683</pub-id>, PMID: <pub-id pub-id-type="pmid">33624611</pub-id></citation>
</ref>
<ref id="ref92">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Shepherd</surname> <given-names>R. K.</given-names></name> <name><surname>Carter</surname> <given-names>P. M.</given-names></name> <name><surname>Dalrymple</surname> <given-names>A. N.</given-names></name> <name><surname>Enke</surname> <given-names>Y. L.</given-names></name> <name><surname>Wise</surname> <given-names>A. K.</given-names></name> <name><surname>Nguyen</surname> <given-names>T.</given-names></name> <etal/></person-group>. (<year>2021</year>). <article-title>Platinum dissolution and tissue response following long-term electrical stimulation at high charge densities</article-title>. <source>J. Neural Eng.</source> <volume>18</volume>:<fpage>abe5ba</fpage>. doi: <pub-id pub-id-type="doi">10.1088/1741-2552/abe5ba</pub-id>, PMID: <pub-id pub-id-type="pmid">33578409</pub-id></citation>
</ref>
<ref id="ref93">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Shi</surname> <given-names>D.</given-names></name> <name><surname>Dhawan</surname> <given-names>V.</given-names></name> <name><surname>Cui</surname> <given-names>X. T.</given-names></name></person-group> (<year>2021</year>). <article-title>Bio-integrative design of the neural tissue-device interface</article-title>. <source>Curr. Opin. Biotechnol.</source> <volume>72</volume>, <fpage>54</fpage>&#x2013;<lpage>61</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.copbio.2021.10.003</pub-id>, PMID: <pub-id pub-id-type="pmid">34710753</pub-id></citation>
</ref>
<ref id="ref94">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Shi</surname> <given-names>Y.</given-names></name> <name><surname>Liu</surname> <given-names>R.</given-names></name> <name><surname>He</surname> <given-names>L.</given-names></name> <name><surname>Feng</surname> <given-names>H.</given-names></name> <name><surname>Li</surname> <given-names>Y.</given-names></name> <name><surname>Li</surname> <given-names>Z.</given-names></name></person-group> (<year>2020</year>). <article-title>Recent development of implantable and flexible nerve electrodes</article-title>. <source>Smart Mater. Med.</source> <volume>1</volume>, <fpage>131</fpage>&#x2013;<lpage>147</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.smaim.2020.08.002</pub-id></citation>
</ref>
<ref id="ref95">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Shih</surname> <given-names>M.</given-names></name> <name><surname>Kuo</surname> <given-names>C.-T.</given-names></name> <name><surname>Lin</surname> <given-names>M.-H.</given-names></name> <name><surname>Chuang</surname> <given-names>Y.-J.</given-names></name> <name><surname>Chen</surname> <given-names>H.</given-names></name> <name><surname>Yew</surname> <given-names>T.-R.</given-names></name></person-group> (<year>2020</year>). <article-title>A 3D-CNT micro-electrode array for zebrafish ECG study including directionality measurement and drug test</article-title>. <source>Biocyber. Biomed. Eng.</source> <volume>40</volume>, <fpage>701</fpage>&#x2013;<lpage>708</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.bbe.2020.02.008</pub-id></citation>
</ref>
<ref id="ref96">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Shin</surname> <given-names>H.</given-names></name> <name><surname>Jeong</surname> <given-names>S.</given-names></name> <name><surname>Lee</surname> <given-names>J.-H.</given-names></name> <name><surname>Sun</surname> <given-names>W.</given-names></name> <name><surname>Choi</surname> <given-names>N.</given-names></name> <name><surname>Cho</surname> <given-names>I.-J.</given-names></name></person-group> (<year>2021</year>). <article-title>3D high-density microelectrode array with optical stimulation and drug delivery for investigating neural circuit dynamics</article-title>. <source>Nat. Commun.</source> <volume>12</volume>, <fpage>1</fpage>&#x2013;<lpage>18</lpage>. doi: <pub-id pub-id-type="doi">10.1038/s41467-020-20763-3</pub-id></citation>
</ref>
<ref id="ref97">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Shmoel</surname> <given-names>N.</given-names></name> <name><surname>Rabieh</surname> <given-names>N.</given-names></name> <name><surname>Ojovan</surname> <given-names>S. M.</given-names></name> <name><surname>Erez</surname> <given-names>H.</given-names></name> <name><surname>Maydan</surname> <given-names>E.</given-names></name> <name><surname>Spira</surname> <given-names>M. E.</given-names></name></person-group> (<year>2016</year>). <article-title>Multisite electrophysiological recordings by self-assembled loose-patch-like junctions between cultured hippocampal neurons and mushroom-shaped microelectrodes</article-title>. <source>Sci. Rep.</source> <volume>6</volume>:<fpage>27110</fpage>. doi: <pub-id pub-id-type="doi">10.1038/srep27110</pub-id>, PMID: <pub-id pub-id-type="pmid">27256971</pub-id></citation>
</ref>
<ref id="ref98">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Siddiqui</surname> <given-names>M. K.</given-names></name> <name><surname>Islam</surname> <given-names>M. Z.</given-names></name> <name><surname>Kabir</surname> <given-names>M. A.</given-names></name></person-group> (<year>2019</year>). <article-title>A novel quick seizure detection and localization through brain data mining on ECoG dataset</article-title>. <source>Neur. Comput. Appl.</source> <volume>31</volume>, <fpage>5595</fpage>&#x2013;<lpage>5608</lpage>. doi: <pub-id pub-id-type="doi">10.1007/s00521-018-3381-9</pub-id></citation>
</ref>
<ref id="ref2009">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Silveira</surname> <given-names>C.</given-names></name> <name><surname>Brunton</surname> <given-names>E.</given-names></name> <name><surname>Escobedo-Cousin</surname> <given-names>E.</given-names></name> <name><surname>Gupta</surname> <given-names>G.</given-names></name> <name><surname>Whittaker</surname> <given-names>R.</given-names></name> <name><surname>O&#x2019;neill</surname> <given-names>A.</given-names></name> <etal/></person-group>. (<year>2020</year>). <article-title>W:Ti flexible transversal electrode array for peripheral nerve stimulation: a feasibility study</article-title>. <source>IEEE Trans. Neural. Syst. Rehabil. Eng.</source> <volume>28</volume>, <fpage>2136</fpage>&#x2013;<lpage>2143</lpage>., PMID: <pub-id pub-id-type="pmid">31308234</pub-id></citation>
</ref>
<ref id="ref99">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Song</surname> <given-names>E.</given-names></name> <name><surname>Chiang</surname> <given-names>C.-H.</given-names></name> <name><surname>Li</surname> <given-names>R.</given-names></name> <name><surname>Jin</surname> <given-names>X.</given-names></name> <name><surname>Zhao</surname> <given-names>J.</given-names></name> <name><surname>Hill</surname> <given-names>M.</given-names></name> <etal/></person-group>. (<year>2019</year>). <article-title>Flexible electronic/optoelectronic microsystems with scalable designs for chronic biointegration</article-title>. <source>Proc. Natl. Acad. Sci.</source> <volume>116</volume>, <fpage>15398</fpage>&#x2013;<lpage>15406</lpage>. doi: <pub-id pub-id-type="doi">10.1073/pnas.1907697116</pub-id>, PMID: <pub-id pub-id-type="pmid">31308234</pub-id></citation>
</ref>
<ref id="ref100">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Steinmetz</surname> <given-names>N. A.</given-names></name> <name><surname>Aydin</surname> <given-names>C.</given-names></name> <name><surname>Lebedeva</surname> <given-names>A.</given-names></name> <name><surname>Okun</surname> <given-names>M.</given-names></name> <name><surname>Pachitariu</surname> <given-names>M.</given-names></name> <name><surname>Bauza</surname> <given-names>M.</given-names></name> <etal/></person-group>. (<year>2021</year>). <article-title>Neuropixels 2.0: a miniaturized high-density probe for stable, long-term brain recordings</article-title>. <source>Science</source> <volume>372</volume>:<fpage>258</fpage>.</citation>
</ref>
<ref id="ref101">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Steins</surname> <given-names>H.</given-names></name> <name><surname>Mierzejewski</surname> <given-names>M.</given-names></name> <name><surname>Brauns</surname> <given-names>L.</given-names></name> <name><surname>Stumpf</surname> <given-names>A.</given-names></name> <name><surname>Kohler</surname> <given-names>A.</given-names></name> <name><surname>Heusel</surname> <given-names>G.</given-names></name> <etal/></person-group>. (<year>2022</year>). <article-title>A flexible protruding microelectrode array for neural interfacing in bioelectronic medicine</article-title>. <source>Microsyst. Nanoeng.</source> <volume>8</volume>:<fpage>131</fpage>. doi: <pub-id pub-id-type="doi">10.1038/s41378-022-00466-z</pub-id>, PMID: <pub-id pub-id-type="pmid">36568135</pub-id></citation>
</ref>
<ref id="ref102">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sun</surname> <given-names>F.</given-names></name> <name><surname>Xiong</surname> <given-names>Z.</given-names></name> <name><surname>Park</surname> <given-names>J.</given-names></name> <name><surname>Xu</surname> <given-names>G.</given-names></name></person-group> (<year>2021</year>). <article-title>Close-packed PEDOT: PSS-coated graphene microelectrodes for high-resolution interrogation of neural activity</article-title>. <source>IEEE Trans. Electr. Dev.</source> <volume>68</volume>, <fpage>3080</fpage>&#x2013;<lpage>3086</lpage>. doi: <pub-id pub-id-type="doi">10.1109/TED.2021.3074353</pub-id></citation>
</ref>
<ref id="ref103">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sundaram</surname> <given-names>S.</given-names></name> <name><surname>Kellnhofer</surname> <given-names>P.</given-names></name> <name><surname>Li</surname> <given-names>Y.</given-names></name> <name><surname>Zhu</surname> <given-names>J.-Y.</given-names></name> <name><surname>Torralba</surname> <given-names>A.</given-names></name> <name><surname>Matusik</surname> <given-names>W.</given-names></name></person-group> (<year>2019</year>). <article-title>Learning the signatures of the human grasp using a scalable tactile glove</article-title>. <source>Nature</source> <volume>569</volume>, <fpage>698</fpage>&#x2013;<lpage>702</lpage>. doi: <pub-id pub-id-type="doi">10.1038/s41586-019-1234-z</pub-id>, PMID: <pub-id pub-id-type="pmid">31142856</pub-id></citation>
</ref>
<ref id="ref104">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Suresh Vajrala</surname> <given-names>V.</given-names></name> <name><surname>Saunier</surname> <given-names>V.</given-names></name> <name><surname>Nowak</surname> <given-names>L.</given-names></name> <name><surname>Flahaut</surname> <given-names>E.</given-names></name> <name><surname>Bergaud</surname> <given-names>C.</given-names></name> <name><surname>Maziz</surname> <given-names>A.</given-names></name></person-group> (<year>2021</year>). <article-title>Carbon nanofiber/PEDOT based macro-porous Composite for high performance multifunctional neural microelectrode</article-title>. <source>ECS Trans.</source> <volume>104</volume>, <fpage>3</fpage>&#x2013;<lpage>5</lpage>. doi: <pub-id pub-id-type="doi">10.1149/10402.0003ecst</pub-id></citation>
</ref>
<ref id="ref105">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Szostak</surname> <given-names>K. M.</given-names></name> <name><surname>Grand</surname> <given-names>L.</given-names></name> <name><surname>Constandinou</surname> <given-names>T. G.</given-names></name></person-group> (<year>2017</year>). <article-title>Neural interfaces for Intracortical recording: requirements, fabrication methods, and characteristics</article-title>. <source>Front. Neurosci.</source> <volume>11</volume>:<fpage>665</fpage>. doi: <pub-id pub-id-type="doi">10.3389/fnins.2017.00665</pub-id>, PMID: <pub-id pub-id-type="pmid">29270103</pub-id></citation>
</ref>
<ref id="ref106">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tanskanen</surname> <given-names>J. M. A.</given-names></name> <name><surname>Ahtiainen</surname> <given-names>A.</given-names></name> <name><surname>Hyttinen</surname> <given-names>J. A. K.</given-names></name></person-group> (<year>2020</year>). <article-title>Toward closed-loop electrical stimulation of neuronal systems: a review</article-title>. <source>Bioelectricity</source> <volume>2</volume>, <fpage>328</fpage>&#x2013;<lpage>347</lpage>. doi: <pub-id pub-id-type="doi">10.1089/bioe.2020.0028</pub-id>, PMID: <pub-id pub-id-type="pmid">34471853</pub-id></citation>
</ref>
<ref id="ref107">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tanwar</surname> <given-names>A.</given-names></name> <name><surname>Gandhi</surname> <given-names>H. A.</given-names></name> <name><surname>Kushwaha</surname> <given-names>D.</given-names></name> <name><surname>Bhattacharya</surname> <given-names>J.</given-names></name></person-group> (<year>2022</year>). <article-title>A review on microelectrode array fabrication techniques and their applications</article-title>. <source>Mater. Today Chem.</source> <volume>26</volume>:<fpage>101153</fpage>. doi: <pub-id pub-id-type="doi">10.1016/j.mtchem.2022.101153</pub-id></citation>
</ref>
<ref id="ref108">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tchoe</surname> <given-names>Y.</given-names></name> <name><surname>Bourhis</surname> <given-names>A. M.</given-names></name> <name><surname>Cleary</surname> <given-names>D. R.</given-names></name> <name><surname>Stedelin</surname> <given-names>B.</given-names></name> <name><surname>Lee</surname> <given-names>J.</given-names></name> <name><surname>Tonsfeldt</surname> <given-names>K. J.</given-names></name> <etal/></person-group>. (<year>2022</year>). <article-title>Human brain mapping with multithousand-channel PtNRGrids resolves spatiotemporal dynamics</article-title>. <source>Sci. Transl. Med.</source> <volume>14</volume>:<fpage>eabj1441</fpage>. doi: <pub-id pub-id-type="doi">10.1126/scitranslmed.abj1441</pub-id>, PMID: <pub-id pub-id-type="pmid">35044788</pub-id></citation>
</ref>
<ref id="ref109">
<citation citation-type="confproc"><person-group person-group-type="author"><name><surname>Tooker</surname> <given-names>A.</given-names></name> <name><surname>Tolosa</surname> <given-names>V.</given-names></name> <name><surname>Shah</surname> <given-names>K.G.</given-names></name> <name><surname>Sheth</surname> <given-names>H.</given-names></name> <name><surname>Felix</surname> <given-names>S.</given-names></name> <name><surname>Delima</surname> <given-names>T.</given-names></name> <etal/></person-group>. (<year>2012</year>). <article-title>Polymer neural interface with dual-sided electrodes for neural stimulation and recording</article-title>, <conf-name>In: 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society: IEEE</conf-name>), <fpage>5999</fpage>&#x2013;<lpage>6002</lpage>.</citation>
</ref>
<ref id="ref110">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tringides</surname> <given-names>C. M.</given-names></name> <name><surname>Mooney</surname> <given-names>D. J.</given-names></name></person-group> (<year>2022</year>). <article-title>Materials for implantable surface electrode arrays: current status and future directions</article-title>. <source>Adv. Mater.</source> <volume>34</volume>:<fpage>2107207</fpage>. doi: <pub-id pub-id-type="doi">10.1002/adma.202107207</pub-id></citation>
</ref>
<ref id="ref111">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Uguz</surname> <given-names>I.</given-names></name> <name><surname>Shepard</surname> <given-names>K. L.</given-names></name></person-group> (<year>2022</year>). <article-title>Spatially controlled, bipolar, cortical stimulation with high-capacitance, mechanically flexible subdural surface microelectrode arrays</article-title>. <source>Sci. Adv.</source> <volume>8</volume>:<fpage>15</fpage>. doi: <pub-id pub-id-type="doi">10.1126/sciadv.abq6354</pub-id></citation>
</ref>
<ref id="ref2003">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Vajrala</surname> <given-names>V. S.</given-names></name> <name><surname>Elkhoury</surname> <given-names>K.</given-names></name> <name><surname>Pautot</surname> <given-names>S.</given-names></name> <name><surname>Bergaud</surname> <given-names>C.</given-names></name> <name><surname>Maziz</surname> <given-names>A.</given-names></name></person-group> (<year>2023</year>). <article-title>Hollow ring-like flexible electrode architecture enabling subcellular multi-directional neural interfacing</article-title>. <source>Bio. Bioelec.</source> <volume>227</volume>, <fpage>115182</fpage>.</citation>
</ref>
<ref id="ref112">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Vitale</surname> <given-names>F.</given-names></name> <name><surname>Shen</surname> <given-names>W.</given-names></name> <name><surname>Driscoll</surname> <given-names>N.</given-names></name> <name><surname>Burrell</surname> <given-names>J. C.</given-names></name> <name><surname>Richardson</surname> <given-names>A. G.</given-names></name> <name><surname>Adewole</surname> <given-names>O.</given-names></name> <etal/></person-group>. (<year>2018</year>). <article-title>Biomimetic extracellular matrix coatings improve the chronic biocompatibility of microfabricated subdural microelectrode arrays</article-title>. <source>PLoS One</source> <volume>13</volume>:<fpage>e0206137</fpage>. doi: <pub-id pub-id-type="doi">10.1371/journal.pone.0206137</pub-id>, PMID: <pub-id pub-id-type="pmid">30383805</pub-id></citation>
</ref>
<ref id="ref113">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wang</surname> <given-names>X.</given-names></name> <name><surname>Hirschberg</surname> <given-names>A. W.</given-names></name> <name><surname>Xu</surname> <given-names>H.</given-names></name> <name><surname>Slingsby-Smith</surname> <given-names>Z.</given-names></name> <name><surname>Lecomte</surname> <given-names>A.</given-names></name> <name><surname>Scholten</surname> <given-names>K.</given-names></name> <etal/></person-group>. (<year>2020</year>). <article-title>A parylene neural probe array for multi-region deep brain recordings</article-title>. <source>J. Microelectromech. Syst.</source> <volume>29</volume>, <fpage>499</fpage>&#x2013;<lpage>513</lpage>. doi: <pub-id pub-id-type="doi">10.1109/JMEMS.2020.3000235</pub-id>, PMID: <pub-id pub-id-type="pmid">35663261</pub-id></citation>
</ref>
<ref id="ref114">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wang</surname> <given-names>Y.</given-names></name> <name><surname>Yang</surname> <given-names>X.</given-names></name> <name><surname>Zhang</surname> <given-names>X.</given-names></name> <name><surname>Wang</surname> <given-names>Y.</given-names></name> <name><surname>Pei</surname> <given-names>W.</given-names></name></person-group> (<year>2023</year>). <article-title>Implantable intracortical microelectrodes: reviewing the present with a focus on the future</article-title>. <source>Microsyst. Nanoeng.</source> <volume>9</volume>:<fpage>7</fpage>. doi: <pub-id pub-id-type="doi">10.1038/s41378-022-00451-6</pub-id>, PMID: <pub-id pub-id-type="pmid">36620394</pub-id></citation>
</ref>
<ref id="ref115">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ward</surname> <given-names>M. P.</given-names></name> <name><surname>Rajdev</surname> <given-names>P.</given-names></name> <name><surname>Ellison</surname> <given-names>C.</given-names></name> <name><surname>Irazoqui</surname> <given-names>P. P.</given-names></name></person-group> (<year>2009</year>). <article-title>Toward a comparison of microelectrodes for acute and chronic recordings</article-title>. <source>Brain Res.</source> <volume>1282</volume>, <fpage>183</fpage>&#x2013;<lpage>200</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.brainres.2009.05.052</pub-id>, PMID: <pub-id pub-id-type="pmid">19486899</pub-id></citation>
</ref>
<ref id="ref116">
<citation citation-type="confproc"><person-group person-group-type="author"><name><surname>Wiedemann</surname> <given-names>L.G.</given-names></name> <name><surname>Mcdaid</surname> <given-names>A.J.</given-names></name></person-group> (<year>2017</year>). <article-title>On the function and robustness of skin-electrode interfaces for high-density electromyography: towards ubiquitous integration with robotics devices</article-title>. <conf-name>In: 2017 IEEE Life Sciences Conference (LSC)</conf-name>, <fpage>137</fpage>&#x2013;<lpage>140</lpage>.</citation>
</ref>
<ref id="ref117">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wu</surname> <given-names>N.</given-names></name> <name><surname>Wan</surname> <given-names>S.</given-names></name> <name><surname>Su</surname> <given-names>S.</given-names></name> <name><surname>Huang</surname> <given-names>H.</given-names></name> <name><surname>Dou</surname> <given-names>G.</given-names></name> <name><surname>Sun</surname> <given-names>L.</given-names></name></person-group> (<year>2021</year>). <article-title>Electrode materials for brain&#x2013;machine interface: a review</article-title>. <source>InfoMat</source> <volume>3</volume>, <fpage>1174</fpage>&#x2013;<lpage>1194</lpage>. doi: <pub-id pub-id-type="doi">10.1002/inf2.12234</pub-id></citation>
</ref>
<ref id="ref118">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Xiang</surname> <given-names>Z.</given-names></name> <name><surname>Wang</surname> <given-names>H.</given-names></name> <name><surname>Wan</surname> <given-names>J.</given-names></name> <name><surname>Miao</surname> <given-names>L.</given-names></name> <name><surname>Xu</surname> <given-names>C.</given-names></name> <name><surname>Zhao</surname> <given-names>P.</given-names></name> <etal/></person-group>. (<year>2022</year>). <article-title>High-density stretchable microelectrode array based on multilayer serpentine interconnections</article-title>. <source>J. Micromech. Microeng.</source> <volume>32</volume>:<fpage>084002</fpage>. doi: <pub-id pub-id-type="doi">10.1088/1361-6439/ac799d</pub-id></citation>
</ref>
<ref id="ref119">
<citation citation-type="confproc"><person-group person-group-type="author"><name><surname>Xu</surname> <given-names>H.</given-names></name> <name><surname>Scholten</surname> <given-names>K.</given-names></name> <name><surname>Jiang</surname> <given-names>W.</given-names></name> <name><surname>Ortigoza-Diaz</surname> <given-names>J.L.</given-names></name> <name><surname>Lu</surname> <given-names>Z.</given-names></name> <etal/></person-group>. (<year>2022</year>). "<article-title>Acute in vivo recording with a generic Parylene microelectrode Array implanted with dip-coating method into the rat brain</article-title>", <conf-name>In: 2022 44th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)</conf-name>, <fpage>214</fpage>&#x2013;<lpage>217</lpage>.</citation>
</ref>
<ref id="ref120">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yan</surname> <given-names>D. X.</given-names></name> <name><surname>Jiman</surname> <given-names>A. A.</given-names></name> <name><surname>Bottorff</surname> <given-names>E. C.</given-names></name> <name><surname>Patel</surname> <given-names>P. R.</given-names></name> <name><surname>Meli</surname> <given-names>D.</given-names></name> <name><surname>Welle</surname> <given-names>E. J.</given-names></name> <etal/></person-group>. (<year>2022</year>). <article-title>Ultraflexible and stretchable Intrafascicular peripheral nerve recording device with axon-dimension, cuff-less microneedle electrode Array</article-title>. <source>Small</source> <volume>18</volume>:<fpage>13</fpage>. doi: <pub-id pub-id-type="doi">10.1002/smll.202200311</pub-id></citation>
</ref>
<ref id="ref121">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yang</surname> <given-names>Y.</given-names></name> <name><surname>Deng</surname> <given-names>Y.</given-names></name> <name><surname>Xu</surname> <given-names>S.</given-names></name> <name><surname>Liu</surname> <given-names>Y.</given-names></name> <name><surname>Liang</surname> <given-names>W.</given-names></name> <name><surname>Zhang</surname> <given-names>K.</given-names></name> <etal/></person-group>. (<year>2023</year>). <article-title>PPy/SWCNTs-modified microelectrode Array for learning and memory model construction through electrical stimulation and detection of in vitro hippocampal neuronal network</article-title>. <source>ACS Appl. Bio Mater.</source> <volume>6</volume>, <fpage>3414</fpage>&#x2013;<lpage>3422</lpage>. doi: <pub-id pub-id-type="doi">10.1021/acsabm.3c00105</pub-id>, PMID: <pub-id pub-id-type="pmid">37071831</pub-id></citation>
</ref>
<ref id="ref122">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yang</surname> <given-names>W.</given-names></name> <name><surname>Gong</surname> <given-names>Y.</given-names></name> <name><surname>Li</surname> <given-names>W.</given-names></name></person-group> (<year>2021a</year>). <article-title>A review: electrode and packaging materials for neurophysiology recording implants</article-title>. <source>Front. Bioeng. Biotechnol.</source> <volume>8</volume>:<fpage>622923</fpage>. doi: <pub-id pub-id-type="doi">10.3389/fbioe.2020.622923</pub-id>, PMID: <pub-id pub-id-type="pmid">33585422</pub-id></citation>
</ref>
<ref id="ref123">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yang</surname> <given-names>W.</given-names></name> <name><surname>Gong</surname> <given-names>Y.</given-names></name> <name><surname>Yao</surname> <given-names>C.-Y.</given-names></name> <name><surname>Shrestha</surname> <given-names>M.</given-names></name> <name><surname>Jia</surname> <given-names>Y.</given-names></name> <name><surname>Qiu</surname> <given-names>Z.</given-names></name> <etal/></person-group>. (<year>2021b</year>). <article-title>A fully transparent, flexible PEDOT:PSS-ITO-ag-ITO based microelectrode array for ECoG recording</article-title>. <source>Lab Chip</source> <volume>21</volume>, <fpage>1096</fpage>&#x2013;<lpage>1108</lpage>. doi: <pub-id pub-id-type="doi">10.1039/D0LC01123A</pub-id></citation>
</ref>
<ref id="ref124">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yin</surname> <given-names>R.</given-names></name> <name><surname>Noble</surname> <given-names>B. C.</given-names></name> <name><surname>He</surname> <given-names>F.</given-names></name> <name><surname>Zolotavin</surname> <given-names>P.</given-names></name> <name><surname>Rathore</surname> <given-names>H.</given-names></name> <name><surname>Jin</surname> <given-names>Y.</given-names></name> <etal/></person-group>. (<year>2022</year>). <article-title>Chronic co-implantation of ultraflexible neural electrodes and a cranial window</article-title>. <source>Neurophotonics</source> <volume>9</volume>:<fpage>032204</fpage>. doi: <pub-id pub-id-type="doi">10.1117/1.NPh.9.3.032204</pub-id>, PMID: <pub-id pub-id-type="pmid">35036472</pub-id></citation>
</ref>
<ref id="ref2010">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yu</surname> <given-names>J.</given-names></name> <name><surname>Ling</surname> <given-names>W.</given-names></name> <name><surname>Li</surname> <given-names>Y.</given-names></name> <name><surname>Ma</surname> <given-names>N.</given-names></name> <name><surname>Wu</surname> <given-names>Z.</given-names></name> <name><surname>Liang</surname> <given-names>R.</given-names></name> <etal/></person-group>. (<year>2021</year>). <article-title>A Multichannel flexible optoelectronic fiber device for distributed implantable neurological stimulation and monitoring</article-title>. <source>Small</source> <volume>17</volume>, <fpage>e2005925</fpage>.</citation>
</ref>
<ref id="ref2006">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zachariah</surname> <given-names>J. S.</given-names></name> <name><surname>Kyounghwan</surname> <given-names>N.</given-names></name> <name><surname>James</surname> <given-names>J.</given-names></name> <name><surname>Lauren</surname> <given-names>R. M.</given-names></name> <name><surname>Alec</surname> <given-names>S.</given-names></name> <name><surname>Eusik</surname> <given-names>Y.</given-names></name> <etal/></person-group>. (<year>2021</year>). <article-title>High-density neural recordings from feline sacral dorsal root ganglia with thin-film array</article-title>. <source>J. Neural Eng.</source> <volume>18</volume>, <fpage>046005</fpage>.</citation>
</ref>
<ref id="ref125">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zeng</surname> <given-names>Q.</given-names></name> <name><surname>Huang</surname> <given-names>Z.</given-names></name></person-group> (<year>2023</year>). <article-title>Challenges and opportunities of implantable neural interfaces: from material, electrochemical and biological perspectives</article-title>. <source>Adv. Funct. Mater.</source> <volume>33</volume>:<fpage>2301223</fpage>. doi: <pub-id pub-id-type="doi">10.1002/adfm.202301223</pub-id></citation>
</ref>
<ref id="ref126">
<citation citation-type="confproc"><person-group person-group-type="author"><name><surname>Zeng</surname> <given-names>N.</given-names></name> <name><surname>Jung</surname> <given-names>T.</given-names></name> <name><surname>Sharma</surname> <given-names>M.</given-names></name> <name><surname>Eichler</surname> <given-names>G.</given-names></name> <name><surname>Fabbri</surname> <given-names>J.</given-names></name> <name><surname>Cotton</surname> <given-names>R.J.</given-names></name> <etal/></person-group>. (<year>2023</year>). <article-title>A wireless, mechanically flexible, 25&#x03BC;m-thick, 65,536-channel subdural surface recording and stimulating microelectrode Array with integrated antennas</article-title>. <conf-name>2023 IEEE Symposium VLSI Technology Circuits (2023)</conf-name>.</citation>
</ref>
<ref id="ref127">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zeng</surname> <given-names>Q.</given-names></name> <name><surname>Wu</surname> <given-names>T.</given-names></name></person-group> (<year>2022</year>). <article-title>Enhanced electrochemical performance of neural electrodes based on PEDOT:PSS hydrogel</article-title>. <source>J. Appl. Polym. Sci.</source> <volume>139</volume>:<fpage>51804</fpage>. doi: <pub-id pub-id-type="doi">10.1002/app.51804</pub-id></citation>
</ref>
<ref id="ref128">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zeng</surname> <given-names>Q.</given-names></name> <name><surname>Yu</surname> <given-names>S.</given-names></name> <name><surname>Fan</surname> <given-names>Z.</given-names></name> <name><surname>Huang</surname> <given-names>Y.</given-names></name> <name><surname>Song</surname> <given-names>B.</given-names></name> <name><surname>Zhou</surname> <given-names>T.</given-names></name></person-group> (<year>2022</year>). <article-title>Nanocone-Array-based platinum-iridium oxide neural microelectrodes: structure, electrochemistry, durability and biocompatibility study</article-title>. <source>Nanomaterials</source> <volume>12</volume>:<fpage>3445</fpage>. doi: <pub-id pub-id-type="doi">10.3390/nano12193445</pub-id></citation>
</ref>
<ref id="ref129">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhang</surname> <given-names>Q.</given-names></name> <name><surname>Hu</surname> <given-names>S.</given-names></name> <name><surname>Talay</surname> <given-names>R.</given-names></name> <name><surname>Xiao</surname> <given-names>Z.</given-names></name> <name><surname>Rosenberg</surname> <given-names>D.</given-names></name> <name><surname>Liu</surname> <given-names>Y.</given-names></name> <etal/></person-group>. (<year>2023</year>). <article-title>A prototype closed-loop brain&#x2013;machine interface for the study and treatment of pain</article-title>. <source>Nat. Biomed. Eng.</source> <volume>7</volume>, <fpage>533</fpage>&#x2013;<lpage>545</lpage>. doi: <pub-id pub-id-type="doi">10.1038/s41551-021-00736-7</pub-id></citation>
</ref>
<ref id="ref130">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhang</surname> <given-names>Y. S.</given-names></name> <name><surname>Khademhosseini</surname> <given-names>A.</given-names></name></person-group> (<year>2017</year>). <article-title>Advances in engineering hydrogels</article-title>. <source>Science</source> <volume>356</volume>:<fpage>eaaf3627</fpage>. doi: <pub-id pub-id-type="doi">10.1126/science.aaf3627</pub-id>, PMID: <pub-id pub-id-type="pmid">28473537</pub-id></citation>
</ref>
<ref id="ref131">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhang</surname> <given-names>Y.</given-names></name> <name><surname>Yang</surname> <given-names>J.</given-names></name> <name><surname>Hou</surname> <given-names>X.</given-names></name> <name><surname>Li</surname> <given-names>G.</given-names></name> <name><surname>Wang</surname> <given-names>L.</given-names></name> <name><surname>Bai</surname> <given-names>N.</given-names></name> <etal/></person-group>. (<year>2022</year>). <article-title>Highly stable flexible pressure sensors with a quasi-homogeneous composition and interlinked interfaces</article-title>. <source>Nat. Commun.</source> <volume>13</volume>:<fpage>1317</fpage>. doi: <pub-id pub-id-type="doi">10.1038/s41467-022-29093-y</pub-id>, PMID: <pub-id pub-id-type="pmid">35273183</pub-id></citation>
</ref>
<ref id="ref132">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhou</surname> <given-names>Y.</given-names></name> <name><surname>Gu</surname> <given-names>C.</given-names></name> <name><surname>Liang</surname> <given-names>J.</given-names></name> <name><surname>Zhang</surname> <given-names>B.</given-names></name> <name><surname>Yang</surname> <given-names>H.</given-names></name> <name><surname>Zhou</surname> <given-names>Z.</given-names></name> <etal/></person-group>. (<year>2022</year>). <article-title>A silk-based self-adaptive flexible opto-electro neural probe</article-title>. <source>Microsyst. Nanoeng.</source> <volume>8</volume>:<fpage>8</fpage>. doi: <pub-id pub-id-type="doi">10.1038/s41378-022-00461-4</pub-id></citation>
</ref>
<ref id="ref133">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhou</surname> <given-names>Y.</given-names></name> <name><surname>Yang</surname> <given-names>H.</given-names></name> <name><surname>Wang</surname> <given-names>X.</given-names></name> <name><surname>Yang</surname> <given-names>H.</given-names></name> <name><surname>Sun</surname> <given-names>K.</given-names></name> <name><surname>Zhou</surname> <given-names>Z.</given-names></name> <etal/></person-group>. (<year>2023</year>). <article-title>A mosquito mouthpart-like bionic neural probe</article-title>. <source>Microsyst. Nanoeng.</source> <volume>9</volume>:<fpage>88</fpage>. doi: <pub-id pub-id-type="doi">10.1038/s41378-023-00565-5</pub-id>, PMID: <pub-id pub-id-type="pmid">37448967</pub-id></citation>
</ref>
<ref id="ref134">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhu</surname> <given-names>M.</given-names></name> <name><surname>Wang</surname> <given-names>H.</given-names></name> <name><surname>Li</surname> <given-names>S.</given-names></name> <name><surname>Liang</surname> <given-names>X.</given-names></name> <name><surname>Zhang</surname> <given-names>M.</given-names></name> <name><surname>Dai</surname> <given-names>X.</given-names></name> <etal/></person-group>. (<year>2021</year>). <article-title>Flexible electrodes for in vivo and in vitro electrophysiological signal recording</article-title>. <source>Adv. Healthc. Mater.</source> <volume>10</volume>:<fpage>e2100646</fpage>. doi: <pub-id pub-id-type="doi">10.1002/adhm.202100646</pub-id></citation>
</ref>
<ref id="ref135">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ziai</surname> <given-names>Y.</given-names></name> <name><surname>Zargarian</surname> <given-names>S. S.</given-names></name> <name><surname>Rinoldi</surname> <given-names>C.</given-names></name> <name><surname>Nakielski</surname> <given-names>P.</given-names></name> <name><surname>Sola</surname> <given-names>A.</given-names></name> <name><surname>Lanzi</surname> <given-names>M.</given-names></name> <etal/></person-group>. (<year>2023</year>). <article-title>Conducting polymer-based nanostructured materials for brain&#x2013;machine interfaces</article-title>. <source>WIREs Nanomed. Nanobiotechnol.</source> <volume>15</volume>:<fpage>e1895</fpage>. doi: <pub-id pub-id-type="doi">10.1002/wnan.1895</pub-id>, PMID: <pub-id pub-id-type="pmid">37141863</pub-id></citation>
</ref>
</ref-list>
</back>
</article>