<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Neurosci.</journal-id>
<journal-title>Frontiers in Neuroscience</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Neurosci.</abbrev-journal-title>
<issn pub-type="epub">1662-453X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fnins.2014.00372</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Neuroscience</subject>
<subj-group>
<subject>Original Research Article</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Artificial Neural Network classification of operator workload with an assessment of time variation and noise-enhancement to increase performance</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes">
<name><surname>Casson</surname> <given-names>Alexander J.</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="author-notes" rid="fn001"><sup>&#x0002A;</sup></xref>
<uri xlink:href="http://community.frontiersin.org/people/u/109714"/>
</contrib>
</contrib-group>
<aff id="aff1"><sup>1</sup><institution>Sensing, Imaging and Signal Processing Group, School of Electrical and Electronic Engineering, The University of Manchester</institution> <country>Manchester, UK</country></aff>
<aff id="aff2"><sup>2</sup><institution>This Work was Carried Out While the Author was with the Optical and Semiconductor Devices Group, Department of Electrical and Electronic Engineering, Imperial College London</institution> <country>London, UK</country></aff>
<author-notes>
<fn fn-type="edited-by"><p>Edited by: Thorsten O. Zander, Technical University of Berlin, Germany</p></fn>
<fn fn-type="edited-by"><p>Reviewed by: Michal Lavidor, Bar Ilan University, Israel; Jonas Br&#x000F6;nstrup, Institute of Technology Berlin, Germany</p></fn>
<fn fn-type="corresp" id="fn001"><p>&#x0002A;Correspondence: Alexander J. Casson, Sensing, Imaging and Signal Processing Group, School of Electrical and Electronic Engineering, The University of Manchester, Sackville Street Building, Manchester, M13 9PL, UK e-mail: <email>alex.casson&#x00040;manchester.ac.uk</email></p></fn>
<fn fn-type="other" id="fn002"><p>This article was submitted to Neuroprosthetics, a section of the journal Frontiers in Neuroscience.</p></fn>
</author-notes>
<pub-date pub-type="epub">
<day>01</day>
<month>12</month>
<year>2014</year>
</pub-date>
<pub-date pub-type="collection">
<year>2014</year>
</pub-date>
<volume>8</volume>
<elocation-id>372</elocation-id>
<history>
<date date-type="received">
<day>14</day>
<month>02</month>
<year>2014</year>
</date>
<date date-type="accepted">
<day>29</day>
<month>10</month>
<year>2014</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x000A9; 2014 Casson.</copyright-statement>
<copyright-year>2014</copyright-year>
<license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract><p>Workload classification&#x02014;the determination of whether a human operator is in a high or low workload state to allow their working environment to be optimized&#x02014;is an emerging application of passive Brain-Computer Interface (BCI) systems. Practical systems must not only accurately detect the current workload state, but also have good temporal performance: requiring little time to set up and train the classifier, and ensuring that the reported performance level is consistent and predictable over time. This paper investigates the temporal performance of an Artificial Neural Network based classification system. For networks trained on little EEG data good classification accuracies (86%) are achieved over very short time frames, but substantial decreases in accuracy are found as the time gap between the network training and the actual use is increased. Noise-enhanced processing, where artificially generated noise is deliberately added to the testing signals, is investigated as a potential technique to mitigate this degradation without requiring the network to be re-trained using more data. Small stochastic resonance effects are demonstrated whereby the classification process gets better in the presence of more noise. The effect is small and does not eliminate the need for re-training, but it is consistent, and this is the first demonstration of such effects for non-evoked/free-running EEG signals suitable for passive BCI.</p></abstract>
<kwd-group>
<kwd>Artificial Neural Network</kwd>
<kwd>Augmented Cognition</kwd>
<kwd>EEG</kwd>
<kwd>noise-enhanced processing</kwd>
<kwd>passive BCI</kwd>
<kwd>stochastic resonance</kwd>
<kwd>workload classification</kwd>
</kwd-group>
<counts>
<fig-count count="7"/>
<table-count count="2"/>
<equation-count count="0"/>
<ref-count count="37"/>
<page-count count="10"/>
<word-count count="7282"/>
</counts>
</article-meta>
</front>
<body>
<sec sec-type="introduction" id="s1">
<title>1. Introduction</title>
<p>Augmented Cognition is a recent research concept focusing on creating the next generation of Human-Computer Interaction devices (Schmorrow and Stanney, <xref ref-type="bibr" rid="B30">2008</xref>). Closed-loop Brain Computer Interfaces (BCIs) are a classic example of such systems. In these, a human uses a computer whilst simultaneously the computer monitors the human and changes its operation based upon the results. Changes might be made to the outputs presented, to the input streams which are used, or to the levels of automation and assistance that are provided, amongst others. For example, workload monitoring systems aim to detect when an operator is in a high or a low workload state to potentially change the speed at which information is presented. As such the work flow and operating environment can be optimized in a real-time and time-varying manner (Wilson and Russell, <xref ref-type="bibr" rid="B34">2007</xref>). Alternatively, workload monitoring could be used to enhance human training: the mental load of a new task can be objectively measured and training times increased or decreased to terminate the training only when the task involves a low level of effort (Ayaz et al., <xref ref-type="bibr" rid="B1">2012</xref>).</p>
<p>Emerging passive BCIs use the spontaneously produced <italic>free-running</italic> EEG (electroencephalogram) signals that are naturally present on the scalp due to the normal functioning of the brain without any specific stimuli present or the user consciously controlling their brain activity (Zander and Kothe, <xref ref-type="bibr" rid="B36">2011</xref>). Workload classification is quickly emerging as a <italic>killer app</italic> for passive BCI as it is particularly suited to being based upon free-running EEG as opposed to evoked responses. At the extreme fatigue end: sleep onset is characterized in free-running EEG by a reduction in alpha (7&#x02013;12 Hz) activity, with this being replaced by theta (4&#x02013;7 Hz) activity (Rechtschaffen and Kales, <xref ref-type="bibr" rid="B28">1968</xref>). This has long been used clinically for sleep staging and there are numerous recent papers (see for example Christensen et al., <xref ref-type="bibr" rid="B6">2012</xref>; Dijksterhuis et al., <xref ref-type="bibr" rid="B10">2013</xref>) demonstrating that frequency band changes can be used to identify less extreme changes in vigilance level.</p>
<p>As with many BCI systems the challenge for workload monitors now is in moving out-of-the-lab and into uncontrolled environments which are significantly corrupted by noise, and in creating systems that are reliable, robust and re-usable. For machine learning based systems an essential parameter in this is the training required to set up the classification process. During training, EEG data which is known to arise during a particular workload state is presented to the classifier, which it then uses to <italic>learn</italic> classification boundaries which can be applied to new EEG data where the workload state is not known. Ideally this classifier generation and training process:</p>
<list list-type="order">
<list-item><p>Leads to the best classification performance when applied to new EEG data.</p></list-item>
<list-item><p>Requires little training data.</p></list-item>
<list-item><p>Maximizes the time before re-training is required.</p></list-item>
</list>
<p>Traditionally much focus has been attached to maximizing condition 1, ensuring that the classification system has good generalisability and can be correctly applied to previously unseen data. However, for practical systems this is not the only objective, and conditions 2 and 3 which determine the <italic>temporal performance</italic> of the system are of critical importance. Recent work (Estepp et al., <xref ref-type="bibr" rid="B13">2011</xref>; Christensen et al., <xref ref-type="bibr" rid="B6">2012</xref>) has suggested that the performance of workload monitors is not constant, instead degrading as the time gap from the training session is increased. (Christensen et al., <xref ref-type="bibr" rid="B6">2012</xref>) showed that some of this performance loss could be recovered by increasing the amount of training data used and including data from multiple EEG sessions: each new EEG session would start with a short new training period to supplement the existing training data that was collected in previous sessions, potentially some time ago.</p>
<p>However, each time the classifier has to be re-trained the user must be placed into a known high or low workload state and new EEG data collected. This requires both a considerable amount of effort, and decreases the time during which the system can be practically used to perform useful classifications. It is thus essential to devise and investigate new techniques that can potentially be used to improve temporal performance without requiring more training sessions to be carried out, and this paper begins this investigation.</p>
<p>This paper presents an Artificial Neural Network based workload classifier for determining operator state from the EEG (Section 2) with its performance evaluated in two novel ways. Firstly, focus is given to the temporal performance of the classification process, quantifying how long a system developed using very little training data can be used before re-training is required (as opposed to maximizing the general performance, condition 1 above). Whilst very good short term performance is obtained, it is verified that the performance does degrade with time.</p>
<p>Secondly, <italic>noise-enhanced processing</italic> is investigated as a technique to mitigate the change in performance. In this, artificially generated corrupting noise is deliberately added to the otherwise raw EEG input signal to evoke <italic>stochastic resonance</italic> from the classification process. This is an effect in non-linear processes whereby performance actually gets better in the presence of small amounts of noise (Kay, <xref ref-type="bibr" rid="B21">2000</xref>; Chen et al., <xref ref-type="bibr" rid="B4">2007</xref>). The method is particularly interesting to explore as noise is widespread in ultra-portable out-of-the-lab EEG recordings, and creating algorithms that are firstly robust to the presence of noise and then even enhanced by the presence of noise can completely change how ultra-portable EEG systems are designed.</p>
<p>As an illustration, nearly all modern dry EEG electrodes are based upon having <italic>fingers</italic>, rather than discs, for easier penetration through the hair, as illustrated in Figure <xref ref-type="fig" rid="F1">1</xref>. However, electrode contact noise is a function of the electrode area (Huigen et al., <xref ref-type="bibr" rid="B18">2002</xref>), and electrode fingering decreases this area. In-depth measurements of dry electrode performance have been presented (Chi et al., <xref ref-type="bibr" rid="B5">2010</xref>; Gandhi et al., <xref ref-type="bibr" rid="B14">2011</xref>; Slater et al., <xref ref-type="bibr" rid="B31">2012</xref>) but most studies report only a correlation coefficient between EEG recorded at nearby locations with wet and dry electrodes. Typical values reported are: &#x0003E;0.93 (Xu et al., <xref ref-type="bibr" rid="B35">2011</xref>); 0.89 (Matthews et al., <xref ref-type="bibr" rid="B22">2007</xref>); 0.83 (Gargiulo et al., <xref ref-type="bibr" rid="B15">2008</xref>); 0.81&#x02013;0.98 (IMEC, <xref ref-type="bibr" rid="B19">2012</xref>); 0.68&#x02013;0.90 (Patki et al., <xref ref-type="bibr" rid="B26">2012</xref>); 0.39&#x02013;0.85 (Estepp et al., <xref ref-type="bibr" rid="B12">2009</xref>). New results in this paper show that even with up to 15 &#x003BC;Vrms of artificial noise added to the raw EEG traces, correlations in-line with those reported for dry electrodes are found.</p>
<fig id="F1" position="float">
<label>Figure 1</label>
<caption><p><bold>Two state-of-the-art commercially available dry EEG electrodes show the common <italic>fingered</italic> configuration</bold>. Photographs by the author.</p></caption>
<graphic xlink:href="fnins-08-00372-g0001.tif"/>
</fig>
<p>Further, in general electronics there is often a trade-off between power consumption and the effective noise present (Harrison and Charles, <xref ref-type="bibr" rid="B17">2003</xref>; Xu et al., <xref ref-type="bibr" rid="B35">2011</xref>; Cuadras et al., <xref ref-type="bibr" rid="B8">2012</xref>). A number of high quality, highly miniaturized wearable EEG units have become commercially in recent years, but with battery lives typically in the 8 h range (Casson, <xref ref-type="bibr" rid="B2">2013</xref>). This power performance still falls far short of <italic>pick up and use</italic> devices and substantial improvements in system power consumptions are still required to realize units that can be trusted to be re-usable session after session. If BCI applications can be enhanced by noise the design of ultra-portable EEG systems is completely changed: more noise is now desirable and this potentially allows the use of even smaller electrodes and lower power consumption processing electronics.</p>
<p>A preliminary investigation of using noise-enhancement in workload monitoring was presented in Casson (<xref ref-type="bibr" rid="B2">2013</xref>). However, this was restricted to the investigation of two subjects and the use of a single Artificial Neural Network based algorithm. The results here have been extended to eight subjects and include the use of an array of neural networks to enable collective decision making.</p>
</sec>
<sec sec-type="materials and methods" id="s2">
<title>2. Materials and methods</title>
<sec>
<title>2.1. Workload task and data</title>
<p>In this work scalp EEG data is used to classify an operator as being in either a high or low workload state whilst they are performing a flight simulator task (Comstock and Arnegard, <xref ref-type="bibr" rid="B7">1992</xref>; Miller Jr., <xref ref-type="bibr" rid="B25">2010</xref>). This task was designed to represent aircraft operations, and particularly those of remote piloting. The data was recorded as part of the 2011 Cognitive State Assessment Competition (Estepp et al., <xref ref-type="bibr" rid="B13">2011</xref>; Christensen et al., <xref ref-type="bibr" rid="B6">2012</xref>) and is publicly available from the competition organizers.<xref ref-type="fn" rid="fn0001"><sup>1</sup></xref> It consisted of two EOG channels (vertical and horizontal) and 19 EEG channels in standard 10&#x02013;20 locations (Fp1, Fp2, F7, F3, Fz, F4, F8, T3, T5, C3, Cz, C4, T4, T6, P3, Pz, P4, O1, O2). All channels used a mastoid reference and ground and a 256 Hz sampling rate.</p>
<p>A total of 118 EEG recordings were performed using eight subjects (15 tests in six subjects, 13 tests in two) on five separate days spread over a month. Each recording day consisted of three 15 min EEG sessions, allowing the temporal performance of the workload monitor to be evaluated on a number of scales. Firstly, within each each 15 min session the EEG data can be divided into training and testing periods which are separated in time by seconds or minutes. Recordings on the same day are separated by minutes or hours, while recordings on different days are separated by days and weeks, and up to a month.</p>
<p>The simulator task was set up such that the difficulty varied dynamically in order to induce known high and low workload states in the operator. No measure of task error was present in the publicly available data and instead the user workload is inferred from the set simulator difficulty. A total of 5 min was spent in each state, with at least a 1 min transition present between task segments classed as high and low workload. Here, only the high and low workload monitoring data segments are analyzed, with the transition segments being discarded. All subjects were trained in the operation of the simulator before the workload monitoring experiment was carried out, eliminating learning effects in the operators themselves.</p>
</sec>
<sec>
<title>2.2. Classification engine</title>
<p>The workload classifier is a feedforward backpropogation Artificial Neural Network (ANN) with five hidden layers (Duda et al., <xref ref-type="bibr" rid="B11">2001</xref>). The network is trained on EEG frequency domain information from seven frequency bands: 0&#x02013;4 Hz, 4&#x02013;7 Hz, 7&#x02013;12 Hz, 12&#x02013;30 Hz, 30&#x02013;42 Hz, 42&#x02013;84 Hz, 84&#x02013;128 Hz; calculated using a 1024 point FFT. This gives a total of 147 input features, and these are generated in 30 s epochs with 25 s overlap such that the assessment of operator state is updated every 5 s. All features are zero mean and unit standard deviation normalized before being passed to the network for classification. The network training used the scaled conjugate gradient backpropagation method and incorporated an early stopping training/validation/testing data split to avoid overfitting. Only 50% of the training vectors in each block of training data were used directly for network training. During network development 10 different networks with random starting weights/biases were used with different random selections of the feature vectors placed in the training sets.</p>
<p>After the classification has been performed, the output of the ANN is a binary state placing the subject into one of the workload categories, with this assigned as the class with the maximum output from the ANN. The classification performance is reported as the percentage of epochs in each testing set which are correctly matched with the known high or low workload in that period in the simulation.</p>
</sec>
<sec>
<title>2.3. Average and temporal performance assessment process</title>
<p>Multiple trained ANNs are generated and evaluated here to assess the performance of the classification process in three ways: the time independent average performance, the temporal performance, and the temporal performance when noise enhancement techniques are applied.</p>
<p>The time independent average performance is found by using a leave-one-out cross validation procedure where all but one of the EEG recordings are used to train the ANN, and the remaining EEG record is used to test the ANN. This process is done on a per-subject basis, and is repeated using all of the different EEG records as the test data. The output is multiple out of sample test performances which are averaged to obtain an overall figure. This is a standard ANN development procedure (Duda et al., <xref ref-type="bibr" rid="B11">2001</xref>), but it uses large amounts of training data (approximately 150 min per subject) and it does not maintain the temporal ordering of the EEG recordings. In many instances the training data will come from time points after the test data (the procedure is non-causal) and the overall average figure does not reflect changes in ANN performance over time.</p>
<p>To assess the temporal performance a modified procedure is used, which maintains causality and uses much less training data. Firstly, a unique ANN is generated for each of the 118 EEG sessions using training data from the start of an EEG session. This network is used to monitor the operator workload in the remainder of this session and demonstrates the <italic>same session</italic> performance when the training and test data segments are very close together in time. The procedure for sub-dividing each EEG session into training/validation data and prospective testing data is illustrated in Figure <xref ref-type="fig" rid="F2">2</xref>. Here, the first 20 epochs (125 s duration) from each of the high and low workload periods are used for generating the network. The remainder of the data is used for testing. For the performance evaluation 11 epochs (80 s) of test data are assessed at a time: this vector is then stepped through all of the available test data epochs to show the achieved classification performance as a function of time. These values can then be averaged to produce an overall figure which does reflect changes in ANN performance over time.</p>
<fig id="F2" position="float">
<label>Figure 2</label>
<caption><p><bold>Training/validation and test data sets are generated from a sliding window allowing the time distance from the training data to be varied and performance evaluated as a function of this distance</bold>.</p></caption>
<graphic xlink:href="fnins-08-00372-g0002.tif"/>
</fig>
<p>The <italic>cross session</italic> temporal performance is then evaluated by re-using the ANNs trained as above (from a part of one session only) and testing them using EEG data collected in different recording sessions. In this case the test EEG is not split into training/test segments, and is instead all used as test data. Multiple time scales are investigated using different configurations of the available data:</p>
<list list-type="bullet">
<list-item><p>Time-scale of minutes: the ANN trained on the first recording session on a day is tested using data from the second recording session on that day. This is repeated for all 5 days of recording.</p></list-item>
<list-item><p>Time-scale of hours: the ANN trained on the first recording session on a day is tested using data from the last recording session on that day. This is repeated for all 5 days of recording.</p></list-item>
<list-item><p>Time-scale of days: the ANN trained on the very first recording session is tested using data from all of the other EEG recording sessions no matter when they were performed, some up to a month later.</p></list-item>
</list>
<p>All of these networks are kept subject specific, and it can be seen that the testing is purely prospective: data from different sessions is not mixed, testing data can only be from the future compared to training data, and the objective is to use little training data to accurately classify operator states which are significantly removed in time from the training data.</p>
</sec>
<sec>
<title>2.4. Noise-enhanced performance assessment process</title>
<p>To investigate noise-enhanced processing two analyses are carried out here. Firstly, to determine suitable noise levels to inject, a raw recorded EEG trace is compared to the same EEG trace after it has had artificial white Gaussian noise deliberately added to it. The correlation coefficient is then found, allowing a comparison with the correlations found in typical wet vs. dry EEG electrode studies (see discussion in Section 1). The white Gaussian noise is generated in M<sc>atlab</sc> using the <monospace>wgn</monospace> function with independent noise streams added to each of the EEG channels. For this analysis a single complete 12.5 h EEG recording is used; the previously publicly available data from (De Clercq et al., <xref ref-type="bibr" rid="B9">2006</xref>; Vergult et al., <xref ref-type="bibr" rid="B32">2007</xref>). This long EEG record is split into multiple shorter duration EEG sections, and the correlation in each section plotted against the duration of the section. This allows the maximum, minimum and median correlation coefficients over time to be found.</p>
<p>Secondly, to assess the noise-enhancement, there are numerous different ways in which noise corrupted EEG data can be passed to the ANN in order to optimally evoke stochastic resonance from the classification procedure, and only one approach is evaluated here. In this, illustrated in Figure <xref ref-type="fig" rid="F3">3</xref>, 10 identical ANNs are used in parallel each driven by EEG traces which have been corrupted by independent noise sources. The classification process is thus repeated 10 times with the output class being decided by a majority vote (in the case of a tie the output is put into the high workload state). The use of artificial noise thus allows multiple attempts of the classification for each individual EEG epoch, which would normally only be possible once.</p>
<fig id="F3" position="float">
<label>Figure 3</label>
<caption><p><bold>Input referred additive noise is used to artificially corrupt an EEG recording before it is passed to an array of workload classification Artificial Neural Networks</bold>. By varying the Root-Mean-Squared (RMS) amplitude of the noise introduced the effect on the algorithm detection performance can be investigated. Here the artificial noise source is white, has an instantaneous value <italic>v</italic><sub><italic>n</italic></sub>(<italic>t</italic>), power spectral density <italic>S</italic>(<italic>f</italic>) and bandwidth of 128 Hz.</p></caption>
<graphic xlink:href="fnins-08-00372-g0003.tif"/>
</fig>
<p>This novel <italic>testing with noise</italic> is employed here to assess the cross session performance. <italic>Training with noise</italic> is a common technique used to increase the accuracy of Artificial Neural Networks by adding small levels of noise to the training data before training the network (Duda et al., <xref ref-type="bibr" rid="B11">2001</xref>). (The aim is to do this multiple times and make the available training data more variable and more representative of future unknown data.) However, this is not employed here. The ANNs are created and trained as detailed above for assessing temporal performance, using the raw recorded EEG signals to generate the input features. Artificial noise is only added in during the testing process. To demonstrate that the results are repeatable, multiple-runs of this 10 ANN configuration using independently generated noise cases have been carried out.</p>
</sec>
</sec>
<sec sec-type="results" id="s3">
<title>3. Results</title>
<sec>
<title>3.1. Average and temporal performance</title>
<p>Across all subjects the average performance from the leave-one-out cross validation procedure is 73%. The per subject performances are given in Table <xref ref-type="table" rid="T1">1</xref>. This is a satisfactory level showing that the networks can be used for determining the operator state, and this information potentially fed back in order to optimize operating procedures.</p>
<table-wrap position="float" id="T1">
<label>Table 1</label>
<caption><p><bold>Classification performance when using the leave-one-out cross validation to assess average performance</bold>.</p></caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th align="left"><bold>Subject</bold></th>
<th align="center"><bold>Performance(%)</bold></th>
</tr>
</thead>
<tbody>
<tr>
<td align="left">A</td>
<td align="center">68.4</td>
</tr>
<tr>
<td align="left">B</td>
<td align="center">73.5</td>
</tr>
<tr>
<td align="left">C</td>
<td align="center">72.6</td>
</tr>
<tr>
<td align="left">D</td>
<td align="center">62.8</td>
</tr>
<tr>
<td align="left">E</td>
<td align="center">79.8</td>
</tr>
<tr>
<td align="left">F</td>
<td align="center">75.5</td>
</tr>
<tr>
<td align="left">G</td>
<td align="center">68.4</td>
</tr>
<tr>
<td align="left">H</td>
<td align="center">79.6</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>The <italic>same session</italic> temporal performance is shown in Figure <xref ref-type="fig" rid="F4">4</xref>. For illustrating the spread of results, Figure <xref ref-type="fig" rid="F4">4</xref> breaks down the performance per subject, and plots the mean performance as the time distance between the training and test data is increased. Vertical lines illustrate the distribution of results across the 15 EEG records from each subject (13 in subjects C and D). Combining all of these results together the overall average performance, where all the performances in Figure <xref ref-type="fig" rid="F4">4</xref> are averaged to produce a single value for each person and then averaged again across the 8 subjects, is 86%.</p>
<fig id="F4" position="float">
<label>Figure 4</label>
<caption><p><bold>Classifier performance when test data is from the same EEG session as the training data</bold>. Plotted lines show the mean performance across all 15 sessions in each subject (13 for C and D) and the mean absolute deviation from this.</p></caption>
<graphic xlink:href="fnins-08-00372-g0004.tif"/>
</fig>
<p>This is higher than the 73% from the cross-validation results because the ANNs have been trained on only a small amount of data and the ANNs generalize well to new data close in time to this, at the cost of worse performance as the time gap increases. From Figure <xref ref-type="fig" rid="F4">4</xref> it is apparent that even over the time span of seconds to minutes the performance is not constant, with noticeable variations present. In subject B the average classification performance gets better over time, but for all of the other subjects there is a decrease in the average performance as the training data becomes increasingly distant in time, with a mean correlation of &#x02212;0.77.</p>
<p>The impact of extending the time gap to days is shown in the <italic>cross session</italic> results in Figure <xref ref-type="fig" rid="F5">5</xref> which illustrates how well the ANN generated in the very first EEG session can be directly re-used over a long time span. The overall average performance is 57%. To compare this to chance a re-sampling approach has been used where the state classification from the ANN is replaced with that from a random number generator. Random values are drawn from a uniform distribution with it being equally likely to mark an EEG epoch as high or low workload. This artificially generated classification output is then analyzed in exactly the same way as the true ANN output. Simulations over 1000 runs show that the mean performance of this random classifier is 50.0%, and the best chance performance is 52.1%. This indicates that the 57% performance of the ANN is above the chance level, although it is unlikely to be of practical use.</p>
<fig id="F5" position="float">
<label>Figure 5</label>
<caption><p><bold>Workload classification performance in 14 EEG sessions (12 in subjects C and D) when the ANN is trained on 250 s of data from the first recording session and tested on all of the other EEG records, up to a month apart from the training session</bold>. Results are shown for both the no noise classifier and the ANN array with 10 &#x003BC;Vrms of added noise.</p></caption>
<graphic xlink:href="fnins-08-00372-g0005.tif"/>
</fig>
<p>Nevertheless, within this 57% wide per-session performance variances are seen. Many of the records achieve very good classification performances above 70%, even many days after the training session. Similarly, however, many perform at the chance level, and indeed some perform substantially worse than chance such that better classification would be actually obtained by inverting the output of the classification process. From this, it is clear that in some cases it is possible to directly re-use the workload classifier across multiple days, but this must be coupled with a method for assessing whether good classification performance is likely to be obtained.</p>
</sec>
<sec>
<title>3.2. Noise-enhanced performance</title>
<p>Figure <xref ref-type="fig" rid="F5">5</xref> also shows the <italic>cross session</italic> performance of the ANN array when used with 10 &#x003BC;Vrms of artificially generated noise. This result is noise-robust: in the 10 &#x003BC;Vrms case the average performance is decreased only to 56%, while with 5 &#x003BC;Vrms of added noise it remained at 57%.</p>
<p>To put this noise level in context, Figure <xref ref-type="fig" rid="F6">6</xref> shows the correlation coefficients between the 12.5 h raw recorded EEG trace and noise corrupted versions of it, as the coefficient is calculated over different time spans. Coefficients in excess of 0.9 are readily achieved, even in the presence of up to 15 &#x003BC;Vrms noise. Partly this is because the underlying correlation present is not accurately estimated when very short sections of data are analyzed. There is a consistent tendency for the median correlation to be underestimated at the cost of much larger variances.</p>
<fig id="F6" position="float">
<label>Figure 6</label>
<caption><p><bold>Correlation coefficients between a raw EEG trace and a noise corrupted copy of the same EEG trace as the EEG section length used for calculation is changed</bold>. Vertical lines show the maximum, minimum and median correlation values found over a complete 12.5 h EEG recording.</p></caption>
<graphic xlink:href="fnins-08-00372-g0006.tif"/>
</fig>
<p>Given this, the array of ANNs was tested using noise levels of 0, 5, 10, and 20 &#x003BC;Vrms. The resulting temporal performance is summarized in Figure <xref ref-type="fig" rid="F7">7</xref> which demonstrates the average classification performance of the <italic>cross session</italic> ANNs when all of the possible training/test configurations are used to investigate each time gap. In the no noise case this finds a very similar performance degradation to that in (Christensen et al., <xref ref-type="bibr" rid="B6">2012</xref>, Figure <xref ref-type="fig" rid="F6">6</xref>). The achieved performance stabilizes over the time frame of hours to 56%, substantially below the starting performance level (86%), with the temporally independent cross validation results (73%) being between the two.</p>
<fig id="F7" position="float">
<label>Figure 7</label>
<caption><p><bold>Workload classification performance as a function of the time between the training and testing data set</bold>. This is evaluated using the array of Artificial Neural Networks and injecting different levels of artificially generated noise into the input EEG signals.</p></caption>
<graphic xlink:href="fnins-08-00372-g0007.tif"/>
</fig>
<p>Christensen et al. (<xref ref-type="bibr" rid="B6">2012</xref>) demonstrated that some of this performance loss could be recovered by re-training the network with a small amount of known workload state data from each new EEG session, but this is undesirable due to the time and effort required. To avoid this process Figure <xref ref-type="fig" rid="F7">7</xref> also tests the hypothesis of using noise-enhanced processing as a potential mitigation approach which does not require network re-training. A single noise case run of the parallel ANN configuration is presented in Figure <xref ref-type="fig" rid="F7">7</xref>. Apparent is that the 5 and 10 &#x003BC;Vrms cases both show small improvements in classification performance over the time span of minutes to hours. Further, all of the noise levels show a reduction in the mean deviation of the performances, showing that the performance is less variable if additional noise is introduced. However, neither of these effects is substantial: the performance improvement in Figure <xref ref-type="fig" rid="F7">7</xref> is approximately 0.3%, and the improvement in the results spread is less than 1% in most cases.</p>
<p>A repeated measures ANOVA, with null hypothesis that there is no difference between the mean performances in the noise and no noise cases, rejects the null hypothesis (<italic>p</italic> &#x0003D; 0.13 for the 5 &#x003BC;Vrms, minutes case). This indicates that the mean performance change is not significant. Nevertheless, to demonstrate that the noise-enhancement in Figure <xref ref-type="fig" rid="F7">7</xref> (which used a single run of the parallel ANN) is repeatable, 10 independent runs of the parallel ANN configuration have been performed with different input noise signals generated for each run. The performance values in the 5 &#x003BC;Vrms of added noise case, when the training and test EEG data sections are minutes apart, are given in Table <xref ref-type="table" rid="T2">2</xref>. This shows that no performance decreases are present. Instead there is a clear and consistent effect of improved performance with the small amount of noise added. Modeling the probability of the noise-enhanced algorithm being better than the no noise one as a Binomial distribution <italic>B</italic>(10, 0.5) (that is, there is a 50% chance of the noise added case outperforming the no noise case) the probability of all 10 noise added runs having better performance than the no noise one is less than 0.001. Assuming the noise added case is always better, <italic>B</italic>(10, 1), for the 10 runs performed the 95% confidence intervals go down to <italic>p</italic> &#x0003D; 0.69 suggesting as a lower bound that the performance is enhanced in approximately 70% of noise cases.</p>
<table-wrap position="float" id="T2">
<label>Table 2</label>
<caption><p><bold>Classification performance when training and test data are taken from EEG sessions performed on the same day, minutes apart. Results are for 10 independent runs with 5 &#x003BC;Vrms of added white Gaussian noise</bold>.</p></caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th align="left"><bold>No noise</bold></th>
<th align="center"><bold>65.2%</bold></th>
</tr>
</thead>
<tbody>
<tr>
<td align="left">Noise run 1</td>
<td align="center">65.6</td>
</tr>
<tr>
<td align="left">Noise run 2</td>
<td align="center">65.5</td>
</tr>
<tr>
<td align="left">Noise run 3</td>
<td align="center">65.6</td>
</tr>
<tr>
<td align="left">Noise run 4</td>
<td align="center">65.4</td>
</tr>
<tr>
<td align="left">Noise run 5</td>
<td align="center">65.7</td>
</tr>
<tr>
<td align="left">Noise run 6</td>
<td align="center">65.4</td>
</tr>
<tr>
<td align="left">Noise run 7</td>
<td align="center">65.5</td>
</tr>
<tr>
<td align="left">Noise run 8</td>
<td align="center">65.2</td>
</tr>
<tr>
<td align="left">Noise run 9</td>
<td align="center">65.3</td>
</tr>
<tr>
<td align="left">Noise run 10</td>
<td align="center">65.3</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
</sec>
<sec sec-type="discussion" id="s4">
<title>4. Discussion</title>
<p>This paper has presented a passive BCI based workload classification system investigating two of the most important factors for practical out-of-the-lab systems: the performance variation over time; and the noise robustness of the classification process. In-line with previous work, very good classification performance is achieved using little training data when the time gap between the training data and testing data is small.</p>
<sec>
<title>4.1. Average and temporal performance</title>
<p>The cross validation ANNs, which used all of the possible training data regardless of when it was recorded compared to the test data, achieved an average performance level of 73%. This procedure is a standard approach for obtaining the best generalization performance when applied to new EEG data (maximizing criteria 1 from the introduction). However, it uses large amounts of test data from many different recordings to ensure the training data is as representative as possible. This is because when the training features are all temporally close together there is the potential for specific features, such as eye blinks or changes in muscle tone, to be present in the training sections which are not present in subsequent EEG recording sessions. This affects how Independent, Identically Distributed (IID) the feature vectors are, and places a lot of weight on a single training session to be representative in terms of equipment set up, user familiarity and user neurophysiology. Changes in performance in subsequent test sessions could then be due to a change in the mental status, or due to changes in the feature IID distributions.</p>
<p>It is for this reason that the <italic>same session</italic> tests, using ANNs trained using just 250 s of data (maximizing condition 2 from the introduction), achieved better performance (86%), but only over the short time frame where the EEG, feature IID distribution, and user mental state in the test period are very similar to that in the training period. As the time gap between the training data and the testing data increased there was a consistent decrease in the classification performance (Figure <xref ref-type="fig" rid="F4">4</xref>) as the used training EEG becomes less representative of the current testing EEG. This decrease in performance is apparent even over the relatively small time scale of minutes. Over larger time scales, substantial decreases in classification performance are observed with, as would be expected, the performance becoming worse than the 73% achieved when using more temporally spread training data. The average performance leveled off at approximately 57% for prolonged multi-day testing (Figure <xref ref-type="fig" rid="F7">7</xref>) with this degradation occurring over the time frame of hours. This performance level is above chance, but is unlikely to be meaningful for practical use. Moreover, a substantial variance in day-to-day performance was observed (Figure <xref ref-type="fig" rid="F5">5</xref>). On some days the existing neural network could be directly re-applied without further training of the network and very acceptable performances obtained. However, on many days the network achieved poor classification and would not be re-usable.</p>
<p>Only one point in the trade-off between the amount/spread of training data used and the amount/speed of the performance drop off has been investigated in this paper. Classically this trade-off is altered by using more training data: either in advance as in the cross validation approach; or by periodically re-training the network (periodically putting the user in a known workload state to generate new training data). Christensen et al. (<xref ref-type="bibr" rid="B6">2012</xref>) estimated that adding in 2.5 min of known workload state data per class was sufficient for re-training. However, generating this data requires time and effort, which places an emphasis on maximizing the time before re-training is required (maximizing condition 3 from the introduction).</p>
</sec>
<sec>
<title>4.2. Noise-enhanced processing</title>
<p>Noise-enhanced signal processing is proposed here as an algorithmic method for recovering some of the ANN performance when there is a large time gap between the training and test data sections, and so increasing the time before re-training is required. It has the benefits of not requiring any additional training data to be collected and being transparent to the end user.</p>
<p><italic>Stochastic resonance</italic> is a well known but counter-intuitive effect where the performance of a non-linear system actually increases as more noise is present in the system (McDonnell and Abbott, <xref ref-type="bibr" rid="B23">2009</xref>; McDonnell and Ward, <xref ref-type="bibr" rid="B24">2011</xref>). Noise-resonance is commonly seen in biological systems, including neurons and the brain itself (Wiesenfeld and Moss, <xref ref-type="bibr" rid="B33">1995</xref>; Gluckman, <xref ref-type="bibr" rid="B16">1996</xref>; McDonnell and Abbott, <xref ref-type="bibr" rid="B23">2009</xref>) and can be used in signal detection (Kay, <xref ref-type="bibr" rid="B21">2000</xref>; Chen et al., <xref ref-type="bibr" rid="B4">2007</xref>). For example the technique has been used for improving the performance of algorithms for detecting micro-calcifications (a key early sign of cancer) in breast mammograms (Peng et al., <xref ref-type="bibr" rid="B27">2009</xref>), in radar target classification (Jouny, <xref ref-type="bibr" rid="B20">2010</xref>), and is widely used in chromatography (Zhang et al., <xref ref-type="bibr" rid="B37">2014</xref>). It has recently been applied to detecting transient signals in the EEG, both evoked and natural (Casson and Rodriguez-Villegas, <xref ref-type="bibr" rid="B3">2011</xref>; Sampanna and Mitaim, <xref ref-type="bibr" rid="B29">2013</xref>). Given the natural associations between noise and the EEG it is a very relevant technique to attempt to utilize, although it has not previously been applied to free-running EEG, suitable for passive BCI applications.</p>
<p>By using an array of ANNs to perform <italic>testing with noise</italic>, as a complement to the more common <italic>training with noise</italic>, Figure <xref ref-type="fig" rid="F5">5</xref> shows that the workload classification process over the time span of days is robust to 5 and 10 &#x003BC;Vrms of noise being added into the EEG traces. Figure <xref ref-type="fig" rid="F7">7</xref> and Table <xref ref-type="table" rid="T2">2</xref> then demonstrate small stochastic resonance effects whereby the classification performance over the time span of minutes was consistently enhanced by the presence of small amounts of noise. To this end, the application of noise-enhancement has been successful, and this paper is the first demonstration of these effects in free-running EEG. However, while consistent, the achieved improvements are less than 1% and far too small to meaningfully eliminate any re-training required to get good multi-day use of the workload classification training with 250 s of data. It is clear that for free-running EEG (unlike evoked and transient EEG, Casson and Rodriguez-Villegas, <xref ref-type="bibr" rid="B3">2011</xref>; Sampanna and Mitaim, <xref ref-type="bibr" rid="B29">2013</xref>) the potential stochastic resonance effects are either very small or are not yet being exploited optimally.</p>
<p>Only one arrangement for introducing noise has been investigated here, but the process introduces many new degrees of freedom in terms of how much noise is added, its spectral composition and the parallel processing and multiple-runs options that it enables. Noise-enhancement and stochastic resonance effects are only just starting to be exploited in BCI applications, and if further established these new degrees of freedom are potentially highly interesting for re-visiting in other BCI problems where they can be exploited to improve performance.</p>
</sec>
</sec>
<sec sec-type="conclusions" id="s5">
<title>5. Conclusions</title>
<p>This paper has investigated the temporal performance of Artificial Neural Networks for operator workload classification. Networks trained using 150 min of EEG data in a leave-one-out cross validation procedure obtained an average classification performance of 73% (Table <xref ref-type="table" rid="T1">1</xref>). In contrast networks trained on only 250 s of EEG data, and so being much quicker to set up, achieved 86% average performance (Figure <xref ref-type="fig" rid="F4">4</xref>) over a short time frame when the test EEG/user state was very similar to the training data. However, these networks do not generalize well (due to changes in the IID distribution of the features, changes in user state, and similar) which leads to a drop off in classification performance as the time gap between the training and testing data increases (Figure <xref ref-type="fig" rid="F7">7</xref>). This shows that short training periods can be used with the ANN classifiers, but the classifiers will only work for a short amount of time.</p>
<p>To overcome this, noise-enhanced processing was explored as an algorithmic technique for recovering some of the lost performance, increasing the amount of time that the classifier can work for. Noise-enhanced processing is explored because it is potentially transparent to the end user and has interesting correlates with the design of EEG units/electrodes. The results (Table <xref ref-type="table" rid="T2">2</xref>) show that noise enhanced processing has an effect: consistently better performances are obtained; although the current improvements are very small. Nevertheless, the consistent improvement is an interesting result and the first evidence that stochastic resonance effects could be exploited in free-running EEG and passive BCI applications.</p>
</sec>
<sec>
<title>Funding</title>
<p>This work was carried out while the author was at Imperial College London and has been supported by the Junior Research Fellowship of Imperial College London and the Imperial College Open Access fund.</p>
<sec>
<title>Conflict of interest statement</title>
<p>The author declares that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
</sec>
</body>
<back>
<ref-list>
<title>References</title>
<ref id="B1">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ayaz</surname> <given-names>H.</given-names></name> <name><surname>Shewokis</surname> <given-names>P. A.</given-names></name> <name><surname>Bunce</surname> <given-names>S.</given-names></name> <name><surname>Izzetoglu</surname> <given-names>K.</given-names></name> <name><surname>Willems</surname> <given-names>B.</given-names></name> <name><surname>Onaral</surname> <given-names>B.</given-names></name></person-group> (<year>2012</year>). <article-title>Optical brain monitoring for operator training and mental workload assessment</article-title>. <source>Neuroergonomics</source> <volume>59</volume>, <fpage>36</fpage>&#x02013;<lpage>47</lpage>. <pub-id pub-id-type="doi">10.1016/j.neuroimage.2011.06.023</pub-id><pub-id pub-id-type="pmid">21722738</pub-id></citation>
</ref>
<ref id="B2">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Casson</surname> <given-names>A. J.</given-names></name></person-group> (<year>2013</year>). <article-title>Towards noise-enhanced augmented cognition</article-title>, in <source>Foundations of Augmented Cognition, Vol. 8027, of Lecture Notes in Computer Science</source>, eds <person-group person-group-type="editor"><name><surname>Schmorrow</surname> <given-names>D. D.</given-names></name> <name><surname>Fidopiastis</surname> <given-names>C. M.</given-names></name></person-group> (<publisher-loc>Berlin; Heidelberg</publisher-loc>: <publisher-name>Springer</publisher-name>), <fpage>259</fpage>&#x02013;<lpage>268</lpage>. <pub-id pub-id-type="doi">10.1016/j.jneumeth.2011.07.007</pub-id></citation>
</ref>
<ref id="B3">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Casson</surname> <given-names>A. J.</given-names></name> <name><surname>Rodriguez-Villegas</surname> <given-names>E.</given-names></name></person-group> (<year>2011</year>). <article-title>Utilising noise to improve an interictal spike detector</article-title>. <source>J. Neurosci. Methods</source> <volume>201</volume>, <fpage>262</fpage>&#x02013;<lpage>268</lpage>. <pub-id pub-id-type="doi">10.1016/j.jneumeth.2011.07.007</pub-id></citation>
</ref>
<ref id="B4">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chen</surname> <given-names>H.</given-names></name> <name><surname>Varshney</surname> <given-names>P. K.</given-names></name> <name><surname>Kay</surname> <given-names>S. M.</given-names></name> <name><surname>Michels</surname> <given-names>J. H.</given-names></name></person-group> (<year>2007</year>). <article-title>Theory of the stochastic resonance effect in signal detection: part I-fixed detectors</article-title>. <source>IEEE Trans. Signal Process</source>. <volume>55</volume>, <fpage>3172</fpage>&#x02013;<lpage>3184</lpage>. <pub-id pub-id-type="doi">10.1109/TSP.2007.893757</pub-id></citation>
</ref>
<ref id="B5">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chi</surname> <given-names>Y.</given-names></name> <name><surname>Jung</surname> <given-names>T.-P.</given-names></name> <name><surname>Cauwenberghs</surname> <given-names>G.</given-names></name></person-group> (<year>2010</year>). <article-title>Dry-contact and noncontact biopotential electrodes: methodological review</article-title>. <source>IEEE Rev. Biomed. Eng</source>. <volume>3</volume>, <fpage>106</fpage>&#x02013;<lpage>119</lpage>. <pub-id pub-id-type="doi">10.1109/RBME.2010.2084078</pub-id><pub-id pub-id-type="pmid">22275204</pub-id></citation>
</ref>
<ref id="B6">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Christensen</surname> <given-names>J. C.</given-names></name> <name><surname>Estepp</surname> <given-names>J. R.</given-names></name> <name><surname>Wilson</surname> <given-names>G. F.</given-names></name> <name><surname>Russell</surname> <given-names>C. A.</given-names></name></person-group> (<year>2012</year>). <article-title>The effects of day-to-day variability of physiological data on operator functional state classification</article-title>. <source>Neuroimage</source> <volume>59</volume>, <fpage>57</fpage>&#x02013;<lpage>63</lpage>. <pub-id pub-id-type="doi">10.1016/j.neuroimage.2011.07.091</pub-id><pub-id pub-id-type="pmid">21840403</pub-id></citation>
</ref>
<ref id="B7">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Comstock</surname> <given-names>J. R.</given-names></name> <name><surname>Arnegard</surname> <given-names>R. J.</given-names></name></person-group> (<year>1992</year>). <source>The Multi-Attribute Task Battery for Human Operator Workload and Strategic Behavior Research</source>. Technical report, TM-104174, <publisher-name>National Aeronautics and Space Administration Langley Research Center</publisher-name>, <publisher-loc>Hampton, VA</publisher-loc>.</citation>
</ref>
<ref id="B8">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Cuadras</surname> <given-names>A.</given-names></name> <name><surname>Casas</surname> <given-names>O.</given-names></name> <name><surname>Pallas-Areny</surname> <given-names>R.</given-names></name></person-group> (<year>2012</year>). <article-title>Power-noise trade-off in signal amplifiers</article-title>, in <source>IEEE I2MTC</source> (<publisher-loc>Montevideo</publisher-loc>).</citation>
</ref>
<ref id="B9">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>De Clercq</surname> <given-names>W.</given-names></name> <name><surname>Vergult</surname> <given-names>A.</given-names></name> <name><surname>Vanrumste</surname> <given-names>B.</given-names></name> <name><surname>Van Paesschen</surname> <given-names>W.</given-names></name> <name><surname>Van Huffel</surname> <given-names>S.</given-names></name></person-group> (<year>2006</year>). <article-title>Canonical correlation analysis applied to remove muscle artifacts from the electroencephalogram</article-title>. <source>IEEE Trans. Biomed. Eng</source>. <volume>53</volume>, <fpage>2583</fpage>&#x02013;<lpage>2587</lpage>. <pub-id pub-id-type="doi">10.1109/TBME.2006.879459</pub-id><pub-id pub-id-type="pmid">17153216</pub-id></citation>
</ref>
<ref id="B10">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dijksterhuis</surname> <given-names>C.</given-names></name> <name><surname>de Waard</surname> <given-names>D.</given-names></name> <name><surname>Brookhuis</surname> <given-names>K.</given-names></name> <name><surname>Mulder</surname> <given-names>B.</given-names></name> <name><surname>de Jong</surname> <given-names>R.</given-names></name></person-group> (<year>2013</year>). <article-title>Classifying visuomotor workload in a driving simulator using subject specific spatial brain patterns</article-title>. <source>Front. Neurosci</source>. <volume>7</volume>:<issue>149</issue>. <pub-id pub-id-type="doi">10.3389/fnins.2013.00149</pub-id><pub-id pub-id-type="pmid">23970851</pub-id></citation>
</ref>
<ref id="B11">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Duda</surname> <given-names>R. O.</given-names></name> <name><surname>Hart</surname> <given-names>P. E.</given-names></name> <name><surname>Stork</surname> <given-names>D. G.</given-names></name></person-group> (<year>2001</year>). <source>Pattern Classification</source>. <publisher-loc>New York, NY</publisher-loc>: <publisher-name>Wiley</publisher-name>.</citation>
</ref>
<ref id="B12">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Estepp</surname> <given-names>J. R.</given-names></name> <name><surname>Christensen</surname> <given-names>J. C.</given-names></name> <name><surname>Monnin</surname> <given-names>J. W.</given-names></name> <name><surname>Davis</surname> <given-names>I. M.</given-names></name> <name><surname>Wilson</surname> <given-names>G. F.</given-names></name></person-group> (<year>2009</year>). <article-title>Validation of a dry electrode system for EEG</article-title>, in <source>Proceedings HFES</source> (<publisher-loc>San Antonio, TX</publisher-loc>).</citation>
</ref>
<ref id="B13">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Estepp</surname> <given-names>J. R.</given-names></name> <name><surname>Klosterman</surname> <given-names>S. L.</given-names></name> <name><surname>Christensen</surname> <given-names>J. C.</given-names></name></person-group> (<year>2011</year>). <article-title>An assessment of non-stationarity in physiological cognitive state assessment using artificial neural networks</article-title>, in <source>IEEE EMBC</source> (<publisher-loc>Boston, MA</publisher-loc>).</citation>
</ref>
<ref id="B14">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Gandhi</surname> <given-names>N.</given-names></name> <name><surname>Khe</surname> <given-names>C.</given-names></name> <name><surname>Chung</surname> <given-names>D.</given-names></name> <name><surname>Chi</surname> <given-names>Y. M.</given-names></name> <name><surname>Cauwenberghs</surname> <given-names>G.</given-names></name></person-group> (<year>2011</year>). <article-title>Properties of dry and non-contact electrodes for wearable physiological sensors</article-title>, in <source>International Conference BSN</source> (<publisher-loc>Dallas, TX</publisher-loc>).</citation>
</ref>
<ref id="B15">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Gargiulo</surname> <given-names>G.</given-names></name> <name><surname>Bifulco</surname> <given-names>P.</given-names></name> <name><surname>Calvo</surname> <given-names>R. A.</given-names></name> <name><surname>Cesarelli</surname> <given-names>M.</given-names></name> <name><surname>Jin</surname> <given-names>C.</given-names></name> <name><surname>van Schaik</surname> <given-names>A.</given-names></name></person-group> (<year>2008</year>). <article-title>A mobile EEG system with dry electrodes</article-title>, in <source>IEEE BioCAS</source> (<publisher-loc>Baltimore, MD</publisher-loc>).</citation>
</ref>
<ref id="B16">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gluckman</surname> <given-names>B. J.</given-names></name></person-group> (<year>1996</year>). <article-title>Stochastic resonance in a neuronal network from mammalian brain</article-title>. <source>Phys. Rev. Lett</source>. <volume>77</volume>, <fpage>4098</fpage>&#x02013;<lpage>4101</lpage>. <pub-id pub-id-type="doi">10.1103/PhysRevLett.77.4098</pub-id><pub-id pub-id-type="pmid">10062387</pub-id></citation>
</ref>
<ref id="B17">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Harrison</surname> <given-names>R. R.</given-names></name> <name><surname>Charles</surname> <given-names>C.</given-names></name></person-group> (<year>2003</year>). <article-title>A low-power low-noise CMOS amplifier for neural recording applications</article-title>. <source>IEEE J. Solid State Circuits</source>. <volume>38</volume>, <fpage>958</fpage>&#x02013;<lpage>965</lpage>. <pub-id pub-id-type="doi">10.1109/JSSC.2003.811979</pub-id></citation>
</ref>
<ref id="B18">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Huigen</surname> <given-names>E.</given-names></name> <name><surname>Peper</surname> <given-names>A.</given-names></name> <name><surname>Grimbergen</surname> <given-names>C. A.</given-names></name></person-group> (<year>2002</year>). <article-title>Investigation into the origin of the noise of surface electrodes</article-title>. <source>Med. Biol. Eng. Comput</source>. <volume>40</volume>, <fpage>332</fpage>&#x02013;<lpage>338</lpage>. <pub-id pub-id-type="doi">10.1007/BF02344216</pub-id><pub-id pub-id-type="pmid">12195981</pub-id></citation>
</ref>
<ref id="B19">
<citation citation-type="web"><person-group person-group-type="author"><collab>IMEC</collab></person-group> (<year>2012</year>). <source>Holst Centre and Panasonic Present Wireless Low-Power Active-Electrode EEG Headset</source>. Available online at: <ext-link ext-link-type="uri" xlink:href="http://www.imec.be/">http://www.imec.be/</ext-link></citation>
</ref>
<ref id="B20">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jouny</surname> <given-names>I.</given-names></name></person-group> (<year>2010</year>). <article-title>Stochastic resonance and suboptimal radar target classification</article-title>. <source>Proc. SPIE</source> <volume>7696</volume>, <fpage>729612</fpage>. <pub-id pub-id-type="doi">10.1117/12.852552</pub-id></citation>
</ref>
<ref id="B21">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kay</surname> <given-names>S.</given-names></name></person-group> (<year>2000</year>). <article-title>Can detectability be improved by adding noise?</article-title> <source>IEEE Signal Process. Lett</source>. <volume>7</volume>, <fpage>8</fpage>&#x02013;<lpage>10</lpage>. <pub-id pub-id-type="doi">10.1109/97.809511</pub-id></citation>
</ref>
<ref id="B22">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Matthews</surname> <given-names>R.</given-names></name> <name><surname>McDonald</surname> <given-names>N. J.</given-names></name> <name><surname>Hervieux</surname> <given-names>P.</given-names></name> <name><surname>Turner</surname> <given-names>P. J.</given-names></name> <name><surname>Steindorf</surname> <given-names>M. A.</given-names></name></person-group> (<year>2007</year>). <article-title>A wearable physiological sensor suite for unobtrusive monitoring of physiological and cognitive state</article-title>, in <source>IEEE EMBC</source> (<publisher-loc>Lyon</publisher-loc>).</citation>
</ref>
<ref id="B23">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>McDonnell</surname> <given-names>M. D.</given-names></name> <name><surname>Abbott</surname> <given-names>D.</given-names></name></person-group> (<year>2009</year>). <article-title>What is stochastic resonance? definitions, misconceptions, debates, and its relevance to biology</article-title>. <source>PLoS Comput. Biol</source>. <volume>5</volume>:<fpage>e1000348</fpage>. <pub-id pub-id-type="doi">10.1371/journal.pcbi.1000348</pub-id><pub-id pub-id-type="pmid">19562010</pub-id></citation>
</ref>
<ref id="B24">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>McDonnell</surname> <given-names>M. D.</given-names></name> <name><surname>Ward</surname> <given-names>L. M.</given-names></name></person-group> (<year>2011</year>). <article-title>The benefits of noise in neural systems: bridging theory and experiment</article-title>. <source>Nat. Rev. Neurosci</source>. <volume>12</volume>, <fpage>415</fpage>&#x02013;<lpage>426</lpage>. <pub-id pub-id-type="doi">10.1038/nrn3061</pub-id><pub-id pub-id-type="pmid">21685932</pub-id></citation>
</ref>
<ref id="B25">
<citation citation-type="other"><person-group person-group-type="author"><name><surname>Miller</surname> <given-names>W. D.</given-names> <suffix>Jr.</suffix></name></person-group> (<year>2010</year>). <source>The U.S. Air Force-Developed Adaptation of the Multi-Attribute Task Battery for the Assessment of Human Operator Workload and Strategic Behavior</source>, Technical report, AFRL-RH-WP-TR-2010-0133, U.S. Air Force Research Laboratory, Wright-Patterson airforce base.</citation>
</ref>
<ref id="B26">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Patki</surname> <given-names>S.</given-names></name> <name><surname>Grundlehner</surname> <given-names>B.</given-names></name> <name><surname>Verwegen</surname> <given-names>A.</given-names></name> <name><surname>Mitra</surname> <given-names>S.</given-names></name> <name><surname>Xu</surname> <given-names>J.</given-names></name> <name><surname>Matsumoto</surname> <given-names>A.</given-names></name> <etal/></person-group>. (<year>2012</year>). <article-title>Wireless EEG system with real time impedance monitoring and active electrodes</article-title>, in <source>IEEE BioCAS</source> (<publisher-loc>Hsinchu</publisher-loc>).</citation>
</ref>
<ref id="B27">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Peng</surname> <given-names>R.</given-names></name> <name><surname>Chen</surname> <given-names>H.</given-names></name> <name><surname>Varshney</surname> <given-names>P.</given-names></name></person-group> (<year>2009</year>). <article-title>Noise-enhanced detection of micro-calcifications in digital mammograms</article-title>. <source>IEEE J. Sel. Areas Signal Process</source>. <volume>3</volume>, <fpage>62</fpage>&#x02013;<lpage>73</lpage>. <pub-id pub-id-type="doi">10.1109/JSTSP.2008.2011162</pub-id></citation>
</ref>
<ref id="B28">
<citation citation-type="book"><person-group person-group-type="editor"><name><surname>Rechtschaffen</surname> <given-names>A.</given-names></name> <name><surname>Kales</surname> <given-names>A.</given-names></name></person-group> (eds.). (<year>1968</year>). <source>A Manual of Standardized Terminology, Techniques and Scoring System for Sleep Stages of Human Subjects</source>. <publisher-loc>Washington, DC</publisher-loc>: <publisher-name>Public Health Service, U.S. Government Printing Office</publisher-name>.</citation>
</ref>
<ref id="B29">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Sampanna</surname> <given-names>R.</given-names></name> <name><surname>Mitaim</surname> <given-names>S.</given-names></name></person-group> (<year>2013</year>). <article-title>Noise enhanced array signal detection in P300 speller paradigm using ICA-based subspace projections</article-title>, in <source>IEEE EMBC</source> (<publisher-loc>Osaka</publisher-loc>).</citation>
</ref>
<ref id="B30">
<citation citation-type="book"><person-group person-group-type="editor"><name><surname>Schmorrow</surname> <given-names>D. D.</given-names></name> <name><surname>Stanney</surname> <given-names>K. M.</given-names></name></person-group> (eds.). (<year>2008</year>). <source>Augmented Cognition: A Practitioner&#x00027;s Guide</source>. <publisher-loc>Santa Monica, CA</publisher-loc>: <publisher-name>Human Factors and Ergonomics Society</publisher-name>.</citation>
</ref>
<ref id="B31">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Slater</surname> <given-names>J. D.</given-names></name> <name><surname>Kalamangalam</surname> <given-names>G. P.</given-names></name> <name><surname>Hope</surname> <given-names>O.</given-names></name></person-group> (<year>2012</year>). <article-title>Quality assessment of electroencephalography obtained from a &#x0201C;dry electrode&#x0201D; system</article-title>. <source>J. Neurosci. Methods</source> <volume>208</volume>, <fpage>134</fpage>&#x02013;<lpage>137</lpage>. <pub-id pub-id-type="doi">10.1016/j.jneumeth.2012.05.011</pub-id><pub-id pub-id-type="pmid">22633894</pub-id></citation>
</ref>
<ref id="B32">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Vergult</surname> <given-names>A.</given-names></name> <name><surname>De Clercq</surname> <given-names>Q.</given-names></name> <name><surname>Palmini</surname> <given-names>A.</given-names></name> <name><surname>Vanrumste</surname> <given-names>B.</given-names></name> <name><surname>Dupont</surname> <given-names>P.</given-names></name> <name><surname>Van Huffel</surname> <given-names>S.</given-names></name> <etal/></person-group>. (<year>2007</year>). <article-title>Improving the interpretation of ictal scalp EEG: BSS-CCA algorithm for muscle artifact removal</article-title>. <source>Epilepsia</source> <volume>45</volume>, <fpage>950</fpage>&#x02013;<lpage>958</lpage>. <pub-id pub-id-type="doi">10.1111/j.1528-1167.2007.01031.x</pub-id><pub-id pub-id-type="pmid">17381439</pub-id></citation>
</ref>
<ref id="B33">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wiesenfeld</surname> <given-names>K.</given-names></name> <name><surname>Moss</surname> <given-names>F.</given-names></name></person-group> (<year>1995</year>). <article-title>Stochastic resonance and the benefits of noise: from ice ages to crayfish and SQUIDs</article-title>. <source>Nature</source> <volume>373</volume>, <fpage>33</fpage>&#x02013;<lpage>36</lpage>. <pub-id pub-id-type="doi">10.1038/373033a0</pub-id><pub-id pub-id-type="pmid">7800036</pub-id></citation>
</ref>
<ref id="B34">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wilson</surname> <given-names>G. F.</given-names></name> <name><surname>Russell</surname> <given-names>C. A.</given-names></name></person-group> (<year>2007</year>). <article-title>Performance enhancement in a UAV task using psychophysiological determined adaptive aiding</article-title>. <source>Hum. Factors</source> <volume>49</volume>, <fpage>1005</fpage>&#x02013;<lpage>1019</lpage>. <pub-id pub-id-type="doi">10.1518/001872007X249875</pub-id><pub-id pub-id-type="pmid">18074700</pub-id></citation>
</ref>
<ref id="B35">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Xu</surname> <given-names>J.</given-names></name> <name><surname>Yazicioglu</surname> <given-names>R. F.</given-names></name> <name><surname>Grundlehner</surname> <given-names>B.</given-names></name> <name><surname>Harpe</surname> <given-names>P.</given-names></name> <name><surname>Makinwa</surname> <given-names>K. A. A.</given-names></name> <name><surname>Van Hoof</surname> <given-names>C.</given-names></name></person-group> (<year>2011</year>). <article-title>A 160 &#x003BC;W 8-channel active electrode system for EEG monitoring</article-title>. <source>IEEE Trans. Biomed. Circuits Syst</source>. <volume>5</volume>, <fpage>555</fpage>&#x02013;<lpage>567</lpage>. <pub-id pub-id-type="doi">10.1109/TBCAS.2011.2170985</pub-id><pub-id pub-id-type="pmid">23852553</pub-id></citation>
</ref>
<ref id="B36">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zander</surname> <given-names>T. O.</given-names></name> <name><surname>Kothe</surname> <given-names>C.</given-names></name></person-group> (<year>2011</year>). <article-title>Towards passive braincomputer interfaces: applying braincomputer interface technology to humanmachine systems in general</article-title>. <source>J. Neural Eng</source>. <volume>8</volume>:<fpage>025005</fpage>. <pub-id pub-id-type="doi">10.1088/1741-2560/8/2/025005</pub-id><pub-id pub-id-type="pmid">21436512</pub-id></citation>
</ref>
<ref id="B37">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhang</surname> <given-names>W.</given-names></name> <name><surname>Guo</surname> <given-names>J.</given-names></name> <name><surname>Xiang</surname> <given-names>B.</given-names></name> <name><surname>Fan</surname> <given-names>H.</given-names></name> <name><surname>Xu</surname> <given-names>F.</given-names></name></person-group> (<year>2014</year>). <article-title>Improving the detection sensitivity of chromatography by stochastic resonance</article-title>. <source>Analyst</source> <volume>139</volume>, <fpage>2099</fpage>&#x02013;<lpage>2107</lpage>. <pub-id pub-id-type="doi">10.1039/C3AN02192K</pub-id><pub-id pub-id-type="pmid">24622614</pub-id></citation>
</ref>
</ref-list>
<fn-group>
<fn id="fn0001"><p><sup>1</sup>Competition contact for data: Justin Estepp, Air Force Research Laboratory, <monospace><email>cognitive.state&#x00040;gmail.com</email></monospace></p></fn>
</fn-group>
</back>
</article>