<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Neurorobot.</journal-id>
<journal-title>Frontiers in Neurorobotics</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Neurorobot.</abbrev-journal-title>
<issn pub-type="epub">1662-5218</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fnbot.2016.00017</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Neuroscience</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Assessment of a Wearable Force- and Electromyography Device and Comparison of the Related Signals for Myocontrol</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name><surname>Connan</surname> <given-names>Mathilde</given-names></name>
<uri xlink:href="http://loop.frontiersin.org/people/370139/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Ruiz Ram&#x000ED;rez</surname> <given-names>Eduardo</given-names></name>
<uri xlink:href="http://loop.frontiersin.org/people/369384/overview"/>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name><surname>Vodermayer</surname> <given-names>Bernhard</given-names></name>
<xref ref-type="author-notes" rid="fn001"><sup>&#x0002A;</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/354713/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Castellini</surname> <given-names>Claudio</given-names></name>
<uri xlink:href="http://loop.frontiersin.org/people/67697/overview"/>
</contrib>
</contrib-group>
<aff><institution>Cognitive Robotics, Institute of Robotics and Mechatronics, German Aerospace Center (DLR)</institution> <country>Wessling, Germany</country></aff>
<author-notes>
<fn fn-type="edited-by"><p>Edited by: Ricardo Chavarriaga, &#x000C9;cole Polytechnique F&#x000E9;d&#x000E9;rale de Lausanne (EPFL), Switzerland</p></fn>
<fn fn-type="edited-by"><p>Reviewed by: Sebastian Amsuess, Otto Bock, Germany; Francesco Clemente, Scuola Superiore Sant&#x00027;Anna, Italy</p></fn>
<fn fn-type="corresp" id="fn001"><p>&#x0002A;Correspondence: Bernhard Vodermayer <email>bernhard.vodermayer&#x00040;dlr.de</email></p></fn>
</author-notes>
<pub-date pub-type="epub">
<day>17</day>
<month>11</month>
<year>2016</year>
</pub-date>
<pub-date pub-type="collection">
<year>2016</year>
</pub-date>
<volume>10</volume>
<elocation-id>17</elocation-id>
<history>
<date date-type="received">
<day>18</day>
<month>07</month>
<year>2016</year>
</date>
<date date-type="accepted">
<day>21</day>
<month>10</month>
<year>2016</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x000A9; 2016 Connan, Ruiz Ram&#x000ED;rez, Vodermayer and Castellini.</copyright-statement>
<copyright-year>2016</copyright-year>
<copyright-holder>Connan, Ruiz Ram&#x000ED;rez, Vodermayer and Castellini</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license>
</permissions>
<abstract><p>In the frame of assistive robotics, multi-finger prosthetic hand/wrists have recently appeared, offering an increasing level of dexterity; however, in practice their control is limited to a few hand grips and still unreliable, with the effect that pattern recognition has not yet appeared in the clinical environment. According to the scientific community, one of the keys to improve the situation is multi-modal sensing, i.e., using diverse sensor modalities to interpret the subject&#x00027;s intent and improve the reliability and safety of the control system in daily life activities. In this work, we first describe and test a novel wireless, wearable force- and electromyography device; through an experiment conducted on ten intact subjects, we then compare the obtained signals both qualitatively and quantitatively, highlighting their advantages and disadvantages. Our results indicate that force-myography yields signals which are more stable across time during whenever a pattern is held, than those obtained by electromyography. We speculate that fusion of the two modalities might be advantageous to improve the reliability of myocontrol in the near future.</p></abstract>
<kwd-group>
<kwd>surface electromyography</kwd>
<kwd>force myography</kwd>
<kwd>multi-modal intent detection</kwd>
<kwd>machine learning</kwd>
<kwd>human-machine interfaces</kwd>
<kwd>rehabilitation robotics</kwd>
</kwd-group>
<contract-sponsor id="cn001">Deutsches Zentrum f&#x000FC;r Luft- und Raumfahrt<named-content content-type="fundref-id">10.13039/501100002946</named-content></contract-sponsor>
<counts>
<fig-count count="12"/>
<table-count count="7"/>
<equation-count count="0"/>
<ref-count count="47"/>
<page-count count="13"/>
<word-count count="8681"/>
</counts>
</article-meta>
</front>
<body>
<sec sec-type="intro" id="s1">
<title>1. Introduction</title>
<p>The human hand is a prodigious natural tool, comprising 27 bones and 33 muscles, resulting in a total of 22 degrees of freedom (DOFs) (Biryukova and Yourovskaya, <xref ref-type="bibr" rid="B22">1994</xref>); its sensorial equipment enables us to drive, browse through the pages of a book, hold and manipulate delicate objects as well as heavy tools. Due to this complexity, artificially reproducing its functions is still a challenge for the roboticians. Nevertheless, a mechatronic tool getting close to the human hand is highly desirable in the context, e.g., of dexterous hand prosthetics. Despite the fact that multi-fingered hand prostheses have appeared on the market during the last decade, their level of abandonment remains relatively high (Biddiss and Chau, <xref ref-type="bibr" rid="B5">2007</xref>; Peerdeman et al., <xref ref-type="bibr" rid="B34">2011</xref>). Touch Bionics&#x00027; <italic>i-LIMB</italic>, Otto Bock&#x00027;s <italic>Michelangelo</italic>, Vincent Systems&#x00027; <italic>Vincent Evolution 2</italic> and RSL Steeper&#x00027;s <italic>Bebionic3</italic> are among these examples: with as many as six DOFs, they still are a limited replacement of the hand of an amputee, not mirroring the capabilities of a real human hand. A prosthetic wrist adds at least one DOF to the device and further improves its potential dexterity, but empowering amputees to control such artifacts (myocontrol) is still an open issue.</p>
<p>The academic state-of-the-art of myocontrol relates to the possibility of proportionally and independently controlling each DOF of the prosthesis according to the patient&#x00027;s intent (Sebelius et al., <xref ref-type="bibr" rid="B39">2005</xref>; Cipriani et al., <xref ref-type="bibr" rid="B15">2011a</xref>); however, low stability and accuracy prevent a successful commercialization of such an approach. Myocontrol is still limited to a few DOFs (Arjunan and Kumar, <xref ref-type="bibr" rid="B2">2010</xref>; Yang et al., <xref ref-type="bibr" rid="B45">2014</xref>), and surface electromyography (sEMG) signals are deemed to be no longer enough (Jiang et al., <xref ref-type="bibr" rid="B25">2012a</xref>). Researchers have tried to address this issue by increasing the number of sensors (Tenore et al., <xref ref-type="bibr" rid="B42">2007</xref>), although it is known that four to six channels are acceptable for pattern detection (Young et al., <xref ref-type="bibr" rid="B46">2012</xref>), and/or to find their optimal placement given the characteristics of the stump (Castellini and van der Smagt, <xref ref-type="bibr" rid="B12">2009</xref>; Fang et al., <xref ref-type="bibr" rid="B18">2015</xref>); several pattern recognition algorithms have been studied, such as artificial neural networks (Baspinar et al., <xref ref-type="bibr" rid="B4">2013</xref>), linear discriminant analysis (Khushaba et al., <xref ref-type="bibr" rid="B27">2009</xref>) and non-linear incremental learning (Gijsberts et al., <xref ref-type="bibr" rid="B21">2014</xref>). However, one of the major drawbacks of sEMG signals is their variable nature: sweat, electrode shifts, motion artifacts, ambient noise, cross-talk among deep adjacent muscles and muscular fatigue can crucially affect them (Oskoei and Hu, <xref ref-type="bibr" rid="B33">2007</xref>; Cram and Kasman, <xref ref-type="bibr" rid="B17">2010</xref>; Merletti et al., <xref ref-type="bibr" rid="B29">2011a</xref>; Castellini et al., <xref ref-type="bibr" rid="B9">2014</xref>). In general, any change in the muscle configuration during and after the training of the machine learning algorithm (e.g., the position of the limb and the body and the weights to be lifted during grasping and carrying) must be taken into account (Scheme et al., <xref ref-type="bibr" rid="B38">2010</xref>; Cipriani et al., <xref ref-type="bibr" rid="B16">2011b</xref>). As a result, simultaneous and proportional (s/p) control of each DOF is slow and laborious. Therefore, the application of other types of sensors and sensor combinations is an active field of research (Fougner et al., <xref ref-type="bibr" rid="B20">2011</xref>; Jiang et al., <xref ref-type="bibr" rid="B25">2012a</xref>).</p>
<p>Among non-invasive approaches other than sEMG, electroencephalography (EEG), mechanomyography (MMG), ultrasound imaging also known as sonomyography (SMG), force myography (FMG), functional magnetic resonance imaging and more are considerable options (Lobo-Prat et al., <xref ref-type="bibr" rid="B28">2014</xref>; Ravindra and Castellini, <xref ref-type="bibr" rid="B36">2014</xref>; Fang et al., <xref ref-type="bibr" rid="B18">2015</xref>). Such Human Machine Interfaces (HMIs) have been implemented in distinct studies. However, the research community is recently pushing the development of multi-modal sensing techniques in the field of upper-limb rehabilitation (Fang et al., <xref ref-type="bibr" rid="B18">2015</xref>). For instance, experiments have shown that accelerometer sensor signals can improve the classification accuracy of EMG electrodes (Fougner et al., <xref ref-type="bibr" rid="B20">2011</xref>), as well as a multimodal technique with EMG and Near Infrared Spectroscopy (NIS) (Herrmann and Buchenrieder, <xref ref-type="bibr" rid="B23">2010</xref>), or a combination of EEG and electroneurography (ENG) (Rossini and Rossini, <xref ref-type="bibr" rid="B37">2010</xref>). In brief, a full comparison of the advantages and disadvantages of each type of signal, as well as the possibilities offered by their fusion, is still lacking.</p>
<p>In this study we focus on the joint usage of sEMG and FMG sensors. Surface EMG Merletti et al. (<xref ref-type="bibr" rid="B30">2011b</xref>) detects Motor Unit Activation Potentials, that is, electrical fields generated by motor units during muscle contraction, whereas FMG (Phillips and Craelius, <xref ref-type="bibr" rid="B35">2005</xref>; Wininger et al., <xref ref-type="bibr" rid="B44">2008</xref>) detects the pressure exerted by the muscles toward the surface of the skin by volumetric changes induced during muscle activity. Due to the very different nature of the signals gathered by these two techniques, it seems reasonable that they could be proficiently fused in order to better detect a subject&#x00027;s intent. A simple and low-cost option to record FMG signals is represented by force-sensing resistors (FSRs), whose resistance changes according to the pressure applied to them. This is also our option of choice. These sensors are cheap and very compact. Castellini and Ravindra (<xref ref-type="bibr" rid="B11">2014</xref>) already proved their effectiveness, and established that finger forces can be predicted with the same accuracy than sEMG sensors (Ravindra and Castellini, <xref ref-type="bibr" rid="B36">2014</xref>). Cho et al. (<xref ref-type="bibr" rid="B14">2016</xref>) tested their force sensing system on four amputees and demonstrated that it is possible to classify six primary grips using only FMG with an accuracy of above 70% in the residuum. We describe a novel, modular approach for joint FMG/sEMG intent detection: thanks to a newly developed, fully mobile and wireless acquisition system, we simultaneously gathered FMG and sEMG signals during an experiment in which ten intact subjects performed a repetitive sequence of wrist and hand movements. The collected data was used to assess the desirable characteristics of each modality, while self-assessment questionnaires were used to check that the device was acceptable for the subjects. In the end, we claim that a fusion of the two approaches is potentially better than using them independently for dexterous myocontrol.</p>
</sec>
<sec sec-type="materials and methods" id="s2">
<title>2. Materials and methods</title>
<p>In order to assess the combined data acquisition of sEMG and FMG for myocontrol, we have built a prototype fully wearable, wireless multi-modal myocontrol system. To study its performance, its usability, and the characteristics of the obtained signals, we have involved ten intact human subjects in an experiment with the device as its core. Figure <xref ref-type="fig" rid="F1">1</xref> (left panel) shows the system as worn by a subject: the device is composed of three modules: a set of mixed sEMG/FMG sensors (in this case, arranged on two Velcro bracelets), a Bluetooth analog-to-digital conversion board gathering and transmitting the signals, and a smartphone receiving the data via Bluetooth and able to perform myocontrol via a machine learning algorithm. The board was based upon the work of Brunelli et al. (<xref ref-type="bibr" rid="B7">2015</xref>), whereas the learning algorithm is Incremental Ridge Regression with Random Fourier Features (see below for more details), already been evaluated (in a non-wearable control system) by Gijsberts et al. (<xref ref-type="bibr" rid="B21">2014</xref>) and Strazzulla et al. (<xref ref-type="bibr" rid="B41">2016</xref>). Although not extensively used in this specific experiment, the machine learning algorithm can produce control signals in real time and transmit them to the sensor board, which serves as a relay routing them to a hand prosthetic device connected to it. A block diagram of the whole system is presented in Figure <xref ref-type="fig" rid="F1">1</xref> (right panel).</p>
<fig id="F1" position="float">
<label>Figure 1</label>
<caption><p><bold>(Left)</bold> Overview of the experimental setup. The subject is wearing the mobile system with a wired connection to two sensor bracelets, one endowed with FMG sensors, the other one with sEMG sensors. The Bluetooth data acquisition board is located in a box placed on the right upper-arm. <bold>(Right)</bold> Block diagram of the system; an i-LIMB prosthetic hand by Touch Bionics (not used in this experiment) can be directly controlled by the device.</p></caption>
<graphic xlink:href="fnbot-10-00017-g0001.tif"/>
</fig>
<sec>
<title>2.1. Experimental setup</title>
<sec>
<title>2.1.1. Sensors</title>
<p>Ten Ottobock <italic>MyoBock 13E200</italic> &#x0003D; <italic>50</italic> sensors were used to gather the sEMG signals. They provide on-board amplification, rectification and filtering. Sensors of this kind are a standard in clinical applications, especially in prosthetic sockets.</p>
<p>FMG signals were registered by ten <italic>FSR 400 Short</italic> force-sensing resistors by Interlink Electronics. Made of a robust polymer thick film, each FSR has a 5.6 mm-diameter sensitive area: when a force is applied to its surface, the electrical resistance of the FSR decreases correspondingly. These sensors are cheap (5&#x020AC; apiece), but despite the specified remarkably large sensitivity range (0.2N&#x02013;40N), they have non-negligible hysteresis at high forces, no guarantee of repeatability and a non-linear transfer function. Nonetheless, Castellini and Ravindra (<xref ref-type="bibr" rid="B11">2014</xref>) have shown that for small forces (0N&#x02013;15N) their behavior is largely comparable and their transfer function is almost linear. In our setup, a small printed circuit board with a voltage amplifier (see Figure <xref ref-type="fig" rid="F2">2</xref>) provides the amplification of the FMG signals. The output of the sensor circuit is <inline-formula><mml:math id="M1"><mml:msub><mml:mrow><mml:mi>V</mml:mi></mml:mrow><mml:mrow><mml:mi>o</mml:mi><mml:mi>u</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mfrac><mml:mrow><mml:msub><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msub><mml:msub><mml:mrow><mml:mi>V</mml:mi></mml:mrow><mml:mrow><mml:mi>C</mml:mi><mml:mi>C</mml:mi></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>1</mml:mn></mml:mrow></mml:msub><mml:mo>&#x0002B;</mml:mo><mml:msub><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:mfrac><mml:mo>-</mml:mo><mml:mfrac><mml:mrow><mml:msub><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>1</mml:mn></mml:mrow></mml:msub><mml:msub><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>4</mml:mn></mml:mrow></mml:msub><mml:msub><mml:mrow><mml:mi>V</mml:mi></mml:mrow><mml:mrow><mml:mi>C</mml:mi><mml:mi>C</mml:mi></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>1</mml:mn></mml:mrow></mml:msub><mml:mo>&#x0002B;</mml:mo><mml:msub><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:mfrac><mml:mo>&#x000D7;</mml:mo><mml:mfrac><mml:mrow><mml:mn>1</mml:mn></mml:mrow><mml:mrow><mml:msub><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mi>F</mml:mi><mml:mi>S</mml:mi><mml:mi>R</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfrac></mml:math></inline-formula>, yielding a lowest admissible resistance of <inline-formula><mml:math id="M2"><mml:msub><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mi>F</mml:mi><mml:mi>S</mml:mi><mml:mi>R</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mfrac><mml:mrow><mml:msub><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>1</mml:mn></mml:mrow></mml:msub><mml:msub><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>4</mml:mn></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:mfrac><mml:mo>=</mml:mo><mml:mn>6</mml:mn><mml:mi>k</mml:mi><mml:mi>&#x003A9;</mml:mi></mml:math></inline-formula>, which corresponds to a theoretical maximum force observed on the FSR&#x00027;s surface of 3.33<italic>N</italic> (InterlinkElectronics, <xref ref-type="bibr" rid="B24">2014</xref>).</p>
<fig id="F2" position="float">
<label>Figure 2</label>
<caption><p><bold>(Left)</bold> The amplification circuit for the FSR. <bold>(Right)</bold> The FSR sensor&#x00027;s PCB.</p></caption>
<graphic xlink:href="fnbot-10-00017-g0002.tif"/>
</fig>
<p>In order to provide maximum flexibility in arranging the sensors on the subject&#x00027;s body, specifically on the forearm or stump, uniform 3D-printed housings have been designed for both kinds of sensors. The housings are made of flexible thermoplastic polyurethane and provide adherence to the subject&#x00027;s skin as they are tightened to the arm by a Velcro strap. Each housing provides braces to allow sliding on the strap, so that its position can be individually adjusted and maintained, regardless of the type of sensor (see Figure <xref ref-type="fig" rid="F3">3</xref>). The FSR sensor housing not only serves as a retainer for the sensor and the amplifier, but furthermore comprises a structured geometric body that is divided into two parts: approximately one half is shaped like a cone and pointing toward the FSR sensor&#x00027;s sensitive area, the other half, shaped like a hemisphere, is pointing toward the skin. This geometric shape has been specifically designed to concentrate the force exerted by the muscles on the FSR sensor&#x00027;s sensitive area. The bearing of this structure is realized by a surrounding, thin and flexible membrane with a thickness of 0.5 mm and a total area of 47.5 mm<sup>2</sup> (small diameter 6.3 mm, large diameter 10 mm), linking it to the housing. Even if the elastic and damping properties of the membrane have not been subject to further investigation so far, it is assumed that the membrane may increase the signal stability, i.e., it could hypothetically add a mechanical filtering to the bio-signal. This solution offers the capability to create any combination of FMG and sEMG electrodes. In order to gather signals from the complete circumference of the forearm, the sensors are placed evenly spaced around the forearm/stump. This arrangement, also called <italic>low-density surface electrode layout</italic> or <italic>uniform electrode positioning</italic> (Fang et al., <xref ref-type="bibr" rid="B18">2015</xref>), has already been proven effective for robotic hand prosthesis control in a number of previous publications (Castellini and van der Smagt, <xref ref-type="bibr" rid="B12">2009</xref>, <xref ref-type="bibr" rid="B13">2013</xref>).</p>
<fig id="F3" position="float">
<label>Figure 3</label>
<caption><p><bold>(A)</bold> Exploded view of the 3D-model of the FSR housing. <bold>(B)</bold> 3D-model of the top part of the FSR housing, where the membrane and the conic shape are identified. <bold>(C)</bold> Assembly process of the housing and the FSR sensor. <bold>(D)</bold> Comparison between the final FSR sensor and the EMG sensor.</p></caption>
<graphic xlink:href="fnbot-10-00017-g0003.tif"/>
</fig>
<p>The typical voltage output of the FSR/amplifier/housing complex has further been characterized. The measurements have been performed with a Zwick Roell <italic>ZMART.PRO</italic> compression test device providing fixture of the sensor setup as well as controlled exertion of force with an accuracy of 100 mN. The corresponding output voltage of the device has been measured with a FLUKE 289 Multimeter with an accuracy of 1 mV. The relationship between voltage output and applied force, in a range from 0 to 5.2 N, is linear with a residual average error of about 7% (see Table <xref ref-type="table" rid="T1">1</xref>). It is worth noting that, during the experiment (see below), no FSR ever reached the saturation point, meaning that the FMG signals have all been correctly captured. This matches to a large extent the results obtained in Castellini and Ravindra (<xref ref-type="bibr" rid="B11">2014</xref>) and Ravindra and Castellini (<xref ref-type="bibr" rid="B36">2014</xref>) for a similar device.</p>
<table-wrap position="float" id="T1">
<label>Table 1</label>
<caption><p><bold>Characterization table for one FSR, including the FSR sensor, the amplifier board and the housing</bold>.</p></caption>
<table frame="hsides" rules="groups">
<tbody>
<tr>
<td valign="top" align="left"><bold>Applied force [N]</bold></td>
<td valign="top" align="center"><bold>0.0</bold></td>
<td valign="top" align="center"><bold>0.4</bold></td>
<td valign="top" align="center"><bold>0.8</bold></td>
<td valign="top" align="center"><bold>1.2</bold></td>
<td valign="top" align="center"><bold>1.6</bold></td>
<td valign="top" align="center"><bold>2.0</bold></td>
<td valign="top" align="center"><bold>2.4</bold></td>
<td valign="top" align="center"><bold>2.8</bold></td>
<td valign="top" align="center"><bold>3.2</bold></td>
<td valign="top" align="center"><bold>3.6</bold></td>
<td valign="top" align="center"><bold>4.0</bold></td>
<td valign="top" align="center"><bold>4.4</bold></td>
<td valign="top" align="center"><bold>4.8</bold></td>
<td valign="top" align="center"><bold>5.2</bold></td>
</tr>
<tr>
<td valign="top" align="left"><bold>Output voltage</bold></td>
<td valign="top" align="center"><bold>0.00</bold></td>
<td valign="top" align="center"><bold>0.16</bold></td>
<td valign="top" align="center"><bold>1.02</bold></td>
<td valign="top" align="center"><bold>1.37</bold></td>
<td valign="top" align="center"><bold>1.66</bold></td>
<td valign="top" align="center"><bold>1.98</bold></td>
<td valign="top" align="center"><bold>2.31</bold></td>
<td valign="top" align="center"><bold>2.51</bold></td>
<td valign="top" align="center"><bold>2.73</bold></td>
<td valign="top" align="center"><bold>3.10</bold></td>
<td valign="top" align="center"><bold>3.27</bold></td>
<td valign="top" align="center"><bold>3.49</bold></td>
<td valign="top" align="center"><bold>3.72</bold></td>
<td valign="top" align="center"><bold>3.85</bold></td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<p><italic>The standard deviation with respect to a linear fit is 6.9%. The provided values have been inverted by the zero-value offset voltage (4.2874V)</italic>.</p>
</table-wrap-foot>
</table-wrap>
</sec>
<sec>
<title>2.1.2. Analog-digital conversion and data transfer</title>
<p>A Bluetooth ADC board (Figure <xref ref-type="fig" rid="F4">4</xref>), consisting of a Texas Instrument <italic>MSP430F5529</italic> microcontroller and an on-board Bluetooth chipset, provides analog-to-digital conversion (ADC) of the signals of both the sEMG and FSR sensors, and their wireless transmission. As the microcontroller natively supports only 15 AD-channels, AD-conversion of up to 32 sensors is realized via analog multiplexing, providing a maximum sampling rate of 192.5 Hz for each channel. Since the sEMG sensors already provide rectified and filtered signals with an evaluable bandwidth limited to 10 Hz, the provided sampling frequency is an overshoot (see e.g., Castellini and van der Smagt, <xref ref-type="bibr" rid="B12">2009</xref>). The same argument obviously holds for the FMG signals (Ravindra and Castellini, <xref ref-type="bibr" rid="B36">2014</xref>).</p>
<fig id="F4" position="float">
<label>Figure 4</label>
<caption><p><bold>The bluetooth analog-to-digital conversion board and its functional block representation</bold>.</p></caption>
<graphic xlink:href="fnbot-10-00017-g0004.tif"/>
</fig>
<p>The board employs two UARTs, communicating in turn with the smartphone (via a serial-over-Bluetooth connection) and the prosthesis (in our case, via a simplified RS232 protocol). Hence, the board can also relay control commands to a hand prosthesis. The final cost of the system is estimated to be below 150&#x020AC;.</p>
</sec>
<sec>
<title>2.1.3. Myocontrol host</title>
<p>The wearable myocontrol system is completed by a standard commercial smartphone (Huawei <italic>Honor 6</italic> with a commercial value of about 300&#x020AC;), on which the data processing is performed. This device is equipped with a quad-core Cortex-A15 processor running at 1.7 GHz, 2 GB of RAM and a 3100 mAh Li-Po battery, claimed to keep the smartphone running for 2 full days at moderate usage. Its operating system is Android 4.4 KitKat. The smartphone weighs 132 g and easily fits in a pocket (7 &#x000D7; 0.8 &#x000D7; 14 cm) with its 5-inch display. A C&#x00023; application similar to the one used in Strazzulla et al. (<xref ref-type="bibr" rid="B41">2016</xref>) was implemented, optimized and ported to the smartphone. The application enforces the following functionalities: (a) receiving and storing the data from the ADC board&#x00027;s serial-over-BT port; (b) displaying a visual stimulus, both on the smartphone screen and using the prosthesis; (c) building a prediction model for the control commands; and (d) sending them off to the prosthetic hand at a 10 Hz frequency, through the ADC board&#x00027;s serial-over-BT port. The machine learning method of choice was&#x02014;coherent with our own previous work&#x02014;Incremental Ridge Regression with Random Fourier Features (Gijsberts et al., <xref ref-type="bibr" rid="B21">2014</xref>). As speculated in previous work and now proven, this method provides real-time capable non-linear multivariate regression while saving a lot of computational resources to the point that the maximum usage of the smartphone&#x00027;s CPU showed to be at 14%. Moreover, with the program running and the cell phone display activated and fully lighted, the battery endurance is at approximately 6 h, whereas an endurance of 11 h can be achieved with the display being switched off. For receiving the sample data and sending control commands to the prosthetic hand, the cell phone&#x00027;s internal Bluetooth peripheral has to be activated all the time.</p>
</sec>
</sec>
<sec>
<title>2.2. Experiment description</title>
<sec>
<title>2.2.1. Subjects</title>
<p>Ten intact subjects, nine of which were right-handed (subject No. 9 being the left-handed one), joined the experiment (3 females and 7 males, 28&#x000B1;7 years old, weighing 72.4&#x000B1;9.91 kg, 177.8&#x000B1;12.14 cm tall). Each subject received a thorough description of the experiment, both in oral and written form. Informed written consent was obtained from all participants. Experiments with sEMG and FMG were approved by the Ethical Committee of the DLR.</p>
</sec>
<sec>
<title>2.2.2. Experimental protocol</title>
<p>The experiment consisted of performing ten times the following sequence of wrist and hand movements: (1) wrist flexion, (2) wrist extension, (3) wrist pronation, (4) wrist supination and (5) power grasp. To enforce the opening of the hand the relaxed stance was used, in order to mimic a more natural form of myocontrol. Each movement was visually stimulated on the screen of the smartphone (the name of the required motion would appear on the screen), while the experimenter was visually checking that the movement was actually being enforced, to ensure a correct execution. Each stimulation was administered as follows: the visual stimulus would appear for 2 s to allow the subject reach the full movement, then for 6 s data were captured representing the maximal activation for that particular movement (&#x0201C;activation phase&#x0201D;: only this phase was considered in the offline analysis), then the stimulus would disappear for 2 s to allow the subject return to the resting position. The sequence was administered in the same order to all subjects. The choice of this set of movements was motivated by the well-known importance of controlling at least the wrist pronation/supination (see e.g., Jiang et al., <xref ref-type="bibr" rid="B26">2012b</xref>) together with grasping; for instance, pronation and supination of the wrist are operated by deep muscles (Biryukova and Yourovskaya, <xref ref-type="bibr" rid="B22">1994</xref>), meaning that they are usually hard to detect using sEMG. It is worth mentioning that, to the best of our knowledge, there is so far no commercially available 2-active-DOFs prosthetic wrist, but a few prototypes are being studied [see e.g., the device embedded in the DEKA arm, <ext-link ext-link-type="uri" xlink:href="https://www.youtube.com/watch?v=KCUwoxuAdYQ">https://www.youtube.com/watch?v=KCUwoxuAdYQ</ext-link>, and the prototype by Ottobock which appears for instance in Amsuess et al. (<xref ref-type="bibr" rid="B1">2016</xref>)].</p>
<p>For this specific experiment, the sensors were separated in two different bracelets, the first one with ten sEMG sensors on the left forearm and the second one with ten FSR sensors on the right forearm. The bracelets were located approximately 10 cm below the subject&#x00027;s elbows. This further choice, rather than that of placing twenty sensors on one single forearm, was motivated by the relatively small space available on the forearm of some of the subjects, which would have potentially limited the adhesion of each sensor to the subjects&#x00027; skin. (A similar problem was reported of, e.g., in Castellini and Ravindra, <xref ref-type="bibr" rid="B11">2014</xref>). Of course, this diminishes the comparability of the results from the two sets of sensors, but myocontrol literature has already presented cases in which, for instance, training of a machine-learning-based method has been performed bilaterally, i.e., gathering data and training from the intact forearm and predicting using data from the impaired limb (Castellini et al., <xref ref-type="bibr" rid="B10">2009</xref>; Nielsen et al., <xref ref-type="bibr" rid="B32">2011</xref>). In both these works, no difference was reported in performance whether the forearm to be used was the dominant or non-dominant one.</p>
<p>During the whole experiment, the subjects sat in a relaxed position with their forearms over their thighs and the hands in a lateral position (with the palms looking toward each other); they were advised to perform each movement bilaterally (Figure <xref ref-type="fig" rid="F5">5</xref>). The recorded data kept trace of the FSR and sEMG signals as well as of a numerical identifier univocally representing the stimulated movement. This index was used as the ground truth during the supposed maximal activation of the muscles&#x02014;an instance of <italic>on-off goal-directed stimuli</italic> as already used in, e.g., Sierra Gonz&#x000E1;lez and Castellini (<xref ref-type="bibr" rid="B40">2013</xref>).</p>
<fig id="F5" position="float">
<label>Figure 5</label>
<caption><p><bold>A bird&#x00027;s-eye view of the experiment</bold>.</p></caption>
<graphic xlink:href="fnbot-10-00017-g0005.tif"/>
</fig>
</sec>
<sec>
<title>2.2.3. Data processing</title>
<p>The signals recorded during the experiment were stored to the smartphone&#x00027;s internal memory, then analyzed off-line. Low-pass filtering was applied to both signals (3rd order low-pass digital Butterworth filter with a cutoff frequency of 1 Hz) in order to remove high-frequency disturbances. This is a standard procedure in the field (see e.g., Atzori et al., <xref ref-type="bibr" rid="B3">2014</xref>). For the data processing and the subsequent statistical analysis, the following approaches have been chosen:</p>
<list list-type="order">
<list-item><p><italic>Stability over time:</italic> To investigate which type of signal has the most stability over time, the standard deviation of each signal was calculated and Student&#x00027;s paired-sample <italic>t</italic>-test was applied.</p></list-item>
<list-item><p><italic>Separability of clusters:</italic> Stability of the signals during activation should somehow be reflected in the separability of patterns in the input space, resulting in, e.g., a better classification accuracy when a classification method is employed. Typically (see e.g., Bunderson and Kuiken, <xref ref-type="bibr" rid="B8">2012</xref>), higher separability of clusters means better distinguishability by any pattern classification method and therefore higher stability of the related control. To check whether this was the case, for each subject in the experiment and each pair of clusters (<italic>C</italic><sub><italic>i</italic></sub>, <italic>C</italic><sub><italic>j</italic></sub>) we evaluated Fisher&#x00027;s Separateness Index (Fisher, <xref ref-type="bibr" rid="B19">1936</xref>), defined as the maximum value over <italic>w</italic> of <italic>J</italic>(<italic>w</italic>), where <inline-formula><mml:math id="M3"><mml:mi>J</mml:mi><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:mi>w</mml:mi></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow><mml:mo>=</mml:mo><mml:mfrac><mml:mrow><mml:msup><mml:mrow><mml:mi>w</mml:mi></mml:mrow><mml:mrow><mml:mi>T</mml:mi></mml:mrow></mml:msup><mml:msub><mml:mrow><mml:mi>S</mml:mi></mml:mrow><mml:mrow><mml:mi>B</mml:mi></mml:mrow></mml:msub><mml:mi>w</mml:mi></mml:mrow><mml:mrow><mml:msup><mml:mrow><mml:mi>w</mml:mi></mml:mrow><mml:mrow><mml:mi>T</mml:mi></mml:mrow></mml:msup><mml:msub><mml:mrow><mml:mi>S</mml:mi></mml:mrow><mml:mrow><mml:mi>W</mml:mi></mml:mrow></mml:msub><mml:mi>w</mml:mi></mml:mrow></mml:mfrac></mml:math></inline-formula>. Here <italic>S</italic><sub><italic>B</italic></sub> is the between-clusters scatter matrix, while <italic>S</italic><sub><italic>W</italic></sub> is the within-clusters scatter matrix. <italic>S</italic><sub><italic>B</italic></sub> is given by <inline-formula><mml:math id="M4"><mml:msub><mml:mrow><mml:mi>S</mml:mi></mml:mrow><mml:mrow><mml:mi>B</mml:mi></mml:mrow></mml:msub><mml:mtext>&#x000A0;</mml:mtext><mml:mo>=</mml:mo><mml:mtext>&#x000A0;</mml:mtext><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:msub><mml:mrow><mml:mi>&#x003BC;</mml:mi></mml:mrow><mml:mrow><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mrow><mml:mi>&#x003BC;</mml:mi></mml:mrow><mml:mrow><mml:mi>j</mml:mi></mml:mrow></mml:msub></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow><mml:msup><mml:mrow><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:msub><mml:mrow><mml:mi>&#x003BC;</mml:mi></mml:mrow><mml:mrow><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mrow><mml:mi>&#x003BC;</mml:mi></mml:mrow><mml:mrow><mml:mi>j</mml:mi></mml:mrow></mml:msub></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow><mml:mrow><mml:mi>T</mml:mi></mml:mrow></mml:msup></mml:math></inline-formula> where &#x003BC;<sub><italic>i</italic></sub>, &#x003BC;<sub><italic>j</italic></sub> are the means of clusters <italic>C</italic><sub><italic>i</italic></sub>, <italic>C</italic><sub><italic>j</italic></sub>, while <inline-formula><mml:math id="M5"><mml:msub><mml:mrow><mml:mi>S</mml:mi></mml:mrow><mml:mrow><mml:mi>W</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:munder class="msub"><mml:mrow><mml:mo>&#x02211;</mml:mo></mml:mrow><mml:mrow><mml:mi>n</mml:mi><mml:mo>=</mml:mo><mml:mi>i</mml:mi><mml:mo>,</mml:mo><mml:mi>j</mml:mi></mml:mrow></mml:munder><mml:munder class="msub"><mml:mrow><mml:mo>&#x02211;</mml:mo></mml:mrow><mml:mrow><mml:mi>x</mml:mi><mml:mo>&#x02208;</mml:mo><mml:mi>c</mml:mi><mml:mi>l</mml:mi><mml:mi>u</mml:mi><mml:mi>s</mml:mi><mml:msub><mml:mrow><mml:mi>t</mml:mi></mml:mrow><mml:mrow><mml:mi>n</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:munder><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:mi>x</mml:mi><mml:mo>-</mml:mo><mml:msub><mml:mrow><mml:mi>&#x003BC;</mml:mi></mml:mrow><mml:mrow><mml:mi>n</mml:mi></mml:mrow></mml:msub></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow><mml:msup><mml:mrow><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:mi>x</mml:mi><mml:mo>-</mml:mo><mml:msub><mml:mrow><mml:mi>&#x003BC;</mml:mi></mml:mrow><mml:mrow><mml:mi>n</mml:mi></mml:mrow></mml:msub></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow><mml:mrow><mml:mi>T</mml:mi></mml:mrow></mml:msup></mml:math></inline-formula>, where <italic>x</italic> are the samples in each cluster. Each pairwise Fisher&#x00027;s index was averaged across all subjects and collected in a matrix <italic>S</italic> &#x0003D; {<italic>s</italic><sub><italic>ij</italic></sub>}.</p></list-item>
<list-item><p><italic>sEMG/FMG regression for myocontrol:</italic> A comparative regression accuracy analysis was performed, in order to assess whether sEMG, FMG or their juxtaposition would be significantly better in the framework of wrist/hand prostheses control. The learning algorithm of choice was Incremental Ridge Regression with Random Fourier Features, already successfully used multiple times, e.g., in Gijsberts et al. (<xref ref-type="bibr" rid="B21">2014</xref>) and Ravindra and Castellini (<xref ref-type="bibr" rid="B36">2014</xref>). Ridge Regression builds a linear model <italic>f</italic>(<italic>x</italic>) &#x0003D; <italic>w</italic><sup><italic>T</italic></sup><italic>x</italic>, where <italic>x</italic> denotes the sensor values, <italic>w</italic> is a weighting vector and <italic>f</italic>(<italic>x</italic>) is the predicted output; Random Fourier Features further employ a non-linear mapping from the input space to a higher-, finite-dimensional feature space, where the linear regression is more likely to succeed. (For more details about this algorithm applied for hand prosthesis control, see Gijsberts et al. (<xref ref-type="bibr" rid="B21">2014</xref>)). Ten-fold &#x0201C;leave-one-repetition-out&#x0201D; cross-validation was applied by training each machine on nine of the ten repetitions and testing on the remaining one. The input space was chosen to be either the FMG values, the sEMG values, or their combination, meaning that the FMG and sEMG samples were simply stacked in a 20-dimensional vector and used with the same learning method. The prediction accuracy was measured using the normalized Root Mean-Squared-Error (nRMSE) between the predicted values and the stimulus values. A one-way ANOVA test was performed to investigate whether there was a statistically significant difference in between the three inputs.</p></list-item>
</list> 
</sec>
<sec>
<title>2.2.4. Satisfaction surveys</title>
<p>Additionally, at the end of the experiment, three surveys were administered to each subject, in order to complete the envisaged system assessment with respect to its usability: the System Usability Scale (SUS) (Brooke, <xref ref-type="bibr" rid="B6">1996</xref>), the NASA Task Load Index (NASA, <xref ref-type="bibr" rid="B31">1986</xref>) and a reworking of the Microsoft Desirability Toolkit by Travis (<xref ref-type="bibr" rid="B43">2008</xref>). The SUS consists of ten questions (Table <xref ref-type="table" rid="T2">2</xref>) with answers represented on a 5 point Likert scale (1 - <italic>strongly disagree</italic> to 5 - <italic>strongly agree</italic>). The scoring in this survey is such that the answers to the <italic>strongly agree</italic> positive questions and to the <italic>strongly disagree</italic> negative questions generate a higher impact over the final score. The NASA Task Load Index provides an overall workload score on six subscales: Mental, Physical and Temporal Demands; Own Performance, Effort and Frustration. For each subscale, the answer could be in a range of 21 points, reaching from <italic>very low</italic> to <italic>very high</italic> (Table <xref ref-type="table" rid="T2">2</xref>).</p>
<table-wrap position="float" id="T2">
<label>Table 2</label>
<caption><p><bold>The statements found in the SUS and NASA TLX surveys</bold>.</p></caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th valign="top" align="left" style="background-color:#bbbdc0"><bold>SUS SURVEY</bold></th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">I felt comfortable with the device.</td>
</tr>
<tr>
<td valign="top" align="left">I found the device unnecessarily complex.</td>
</tr>
<tr>
<td valign="top" align="left">I thought the device was easy to use.</td>
</tr>
<tr>
<td valign="top" align="left">I think that I would need the support of a technical person to be able to use this device.</td>
</tr>
<tr>
<td valign="top" align="left">I found the various functions in this system were well integrated.</td>
</tr>
<tr>
<td valign="top" align="left">I thought there was too much inconsistency in this device.</td>
</tr>
<tr>
<td valign="top" align="left">I would imagine that most users would learn to use this device very quickly.</td>
</tr>
<tr>
<td valign="top" align="left">I found the device very cumbersome to use.</td>
</tr>
<tr>
<td valign="top" align="left">I felt very confident using the device.</td>
</tr>
<tr>
<td valign="top" align="left">I needed to learn a lot of things before I could get going with this device.</td>
</tr>
<tr>
<td valign="top" align="left" style="background-color:#bbbdc0"><bold>NASA TLX SURVEY</bold></td>
</tr>
<tr>
<td valign="top" align="left">How mentally demanding was the task?</td>
</tr>
<tr>
<td valign="top" align="left">How physically demanding was the task?</td>
</tr>
<tr>
<td valign="top" align="left">How hurried or rushed was the pace of the task?</td>
</tr>
<tr>
<td valign="top" align="left">How successful were you in accomplishing what you were asked to do?</td>
</tr>
<tr>
<td valign="top" align="left">How hard did you have to work to accomplish your level of performance?</td>
</tr>
<tr>
<td valign="top" align="left">How insecure, discouraged, irritated, stressed, and annoyed were you?</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>Lastly, Travis&#x00027;s survey consists in a series of &#x0201C;reaction cards&#x0201D; with adjectives that could be applied to the system to be tested; the user is asked to select the five cards that most closely match their personal reactions to the system. For the experiment, we used a list of 75 adjectives instead of the cards (most of them based on Travis&#x00027;s questionnaire), then the subject was asked to choose all adjectives he or she felt more related with the device. After that, in a more precise selection, the user had to choose only the 5 most important words and try to give a simple reason about his or her decision.</p>
</sec>
</sec>
</sec>
<sec id="s3">
<title>3. Experimental results</title>
<sec>
<title>3.1. Stability over time</title>
<p>Figure <xref ref-type="fig" rid="F6">6</xref> shows typical FMG and sEMG signals obtained while a subject was performing two repetitions of the five instructed movements (plus the resting state). Due to the carefully chosen amplification/filtering stages of the sensors themselves, the amplitude of the signals obtained from both FMG and sEMG sensors are comparable, and each single produced movement appears as a distinct pattern, well separated in time from the next one as well as from the 2-s intervals allowed for resting and for preparing the next movement. Such behavior is clear, e.g., during the wrist-flexion movement enforced from 60 to 70 s in the Figure (second red bar just above the <italic>x</italic>-axis).</p>
<fig id="F6" position="float">
<label>Figure 6</label>
<caption><p><bold>Typical FSR and sEMG signals obtained from two repetitions of the instructed hand and wrist movements (wrist flexion, wrist extension, wrist pronation, wrist supination, power grasp and rest)</bold>. Colored bars denote the activation phases, during which data were collected to represent the maximal activation of the stimulated movement.</p></caption>
<graphic xlink:href="fnbot-10-00017-g0006.tif"/>
</fig>
<p>Visual inspection seems to indicate that FMG signals are more stable over time <italic>while the subjects are holding the position</italic> than sEMG signals: this is apparent by looking at the &#x0201C;plateaus&#x0201D; created by the FSRs while each movement was enforced; as opposed to that, sEMG signals exhibit the typical oscillating down-ramp pattern due to muscular motor-unit recruitment (Merletti et al., <xref ref-type="bibr" rid="B29">2011a</xref>,<xref ref-type="bibr" rid="B30">b</xref>). To verify that this is the case in general, we evaluated the standard deviation of the FMG and sEMG signals obtained by each subject while performing the first three repetitions of the wrist flexion movement considering the signals during the activation phases only. (Only the three sensors for each set that exhibited the highest amplitude were taken into account.) Considering Table <xref ref-type="table" rid="T3">3</xref>, sEMG signals actually exhibit a significantly higher standard deviation when compared to FMG signals (mean values 0.0087 and 0.0025 in turn, Student&#x00027;s paired-sample <italic>t</italic>-test <italic>p</italic> &#x0003C; 0.01).</p>
<table-wrap position="float" id="T3">
<label>Table 3</label>
<caption><p><bold>Standard deviation of FMG and sEMG sensor signals obtained by each subject during the first three repetitions of the wrist flexion movement</bold>.</p></caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th valign="top" align="left"><bold>Subject &#x00023;</bold></th>
<th valign="top" align="center"><bold>1</bold></th>
<th valign="top" align="center"><bold>2</bold></th>
<th valign="top" align="center"><bold>3</bold></th>
<th valign="top" align="center"><bold>4</bold></th>
<th valign="top" align="center"><bold>5</bold></th>
<th valign="top" align="center"><bold>6</bold></th>
<th valign="top" align="center"><bold>7</bold></th>
<th valign="top" align="center"><bold>8</bold></th>
<th valign="top" align="center"><bold>9</bold></th>
<th valign="top" align="center"><bold>10</bold></th>
<th valign="top" align="center"><bold>Mean</bold></th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">FMG</td>
<td valign="top" align="center">0.0018</td>
<td valign="top" align="center">0.0026</td>
<td valign="top" align="center">0.0006</td>
<td valign="top" align="center">0.0030</td>
<td valign="top" align="center">0.0033</td>
<td valign="top" align="center">0.0042</td>
<td valign="top" align="center">0.0018</td>
<td valign="top" align="center">0.0016</td>
<td valign="top" align="center">0.0028</td>
<td valign="top" align="center">0.0031</td>
<td valign="top" align="center">0.0025</td>
</tr>
<tr>
<td valign="top" align="left">sEMG</td>
<td valign="top" align="center">0.0202</td>
<td valign="top" align="center">0.0111</td>
<td valign="top" align="center">0.0019</td>
<td valign="top" align="center">0.0038</td>
<td valign="top" align="center">0.0144</td>
<td valign="top" align="center">0.0082</td>
<td valign="top" align="center">0.0037</td>
<td valign="top" align="center">0.0065</td>
<td valign="top" align="center">0.0082</td>
<td valign="top" align="center">0.0091</td>
<td valign="top" align="center">0.0087</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<p><italic>Considering the three sensors that exhibited the highest signal amplitude</italic>.</p>
</table-wrap-foot>
</table-wrap>
</sec>
<sec>
<title>3.2. Separability of clusters</title>
<p>Figure <xref ref-type="fig" rid="F7">7</xref> shows typical FMG and sEMG data reduced to three dimensions via Principal Component Analysis (PCA) and colored according to each movement for the cluster separability analysis carried out for both input spaces. In the figure, sEMG clusters appear more stretched than FMG clusters, a behavior very likely due to the above-mentioned oscillations while a movement is being held.</p>
<fig id="F7" position="float">
<label>Figure 7</label>
<caption><p><bold>3D-reduced PCA projections of typical data for each type of sensor, colored according to the stimulated movements</bold>. <bold>(A)</bold> FMG. <bold>(B)</bold> sEMG.</p></caption>
<graphic xlink:href="fnbot-10-00017-g0007.tif"/>
</fig>
<p>Figure <xref ref-type="fig" rid="F8">8</xref> shows the matrices for sEMG and FMG, while Table <xref ref-type="table" rid="T4">4</xref> lists the means of Fisher&#x00027;s Indexes for each subject (the diagonal-zero values are not considered to evaluate the mean values). The Fisher&#x00027;s Index of FMG is higher (therefore better) than that of sEMG (mean values 368.82 and 94.1) with high statistical significance (Student&#x00027;s paired-sample <italic>t</italic>-test <italic>p</italic> &#x0003C; 0.001).</p>
<fig id="F8" position="float">
<label>Figure 8</label>
<caption><p><bold>Fisher&#x00027;s Index matrices for each type of sensor (higher is better)</bold>. <bold>(A)</bold> FSR Fisher&#x00027;s index. <bold>(B)</bold> EMG Fisher&#x00027;s index.</p></caption>
<graphic xlink:href="fnbot-10-00017-g0008.tif"/>
</fig>
<table-wrap position="float" id="T4">
<label>Table 4</label>
<caption><p><bold>Mean Fisher&#x00027;s Index values for each subject and type of sensors</bold>.</p></caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th valign="top" align="left"><bold>Subject &#x00023;</bold></th>
<th valign="top" align="center"><bold>1</bold></th>
<th valign="top" align="center"><bold>2</bold></th>
<th valign="top" align="center"><bold>3</bold></th>
<th valign="top" align="center"><bold>4</bold></th>
<th valign="top" align="center"><bold>5</bold></th>
<th valign="top" align="center"><bold>6</bold></th>
<th valign="top" align="center"><bold>7</bold></th>
<th valign="top" align="center"><bold>8</bold></th>
<th valign="top" align="center"><bold>9</bold></th>
<th valign="top" align="center"><bold>10</bold></th>
<th valign="top" align="center"><bold>Mean</bold></th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Fisher&#x00027;s Index, FMG</td>
<td valign="top" align="center">291.08&#x000B1;227.9</td>
<td valign="top" align="center">616.47&#x000B1;893.5</td>
<td valign="top" align="center">340.22&#x000B1;259.7</td>
<td valign="top" align="center">108.11&#x000B1;50</td>
<td valign="top" align="center">157.50&#x000B1;72.8</td>
<td valign="top" align="center">391.26&#x000B1;527.2</td>
<td valign="top" align="center">432.3&#x000B1;342.2</td>
<td valign="top" align="center">513.18&#x000B1;453.9</td>
<td valign="top" align="center">455.85&#x000B1;532.4</td>
<td valign="top" align="center">382.21&#x000B1;722.2</td>
<td valign="top" align="center">368.82&#x000B1;154.2</td>
</tr>
<tr>
<td valign="top" align="left">Fisher&#x00027;s Index, sEMG</td>
<td valign="top" align="center">87&#x000B1;74.3</td>
<td valign="top" align="center">69.46&#x000B1;45.2</td>
<td valign="top" align="center">71.24&#x000B1;23.6</td>
<td valign="top" align="center">38.03&#x000B1;16.9</td>
<td valign="top" align="center">208.34&#x000B1;279.3</td>
<td valign="top" align="center">67.78&#x000B1;23.3</td>
<td valign="top" align="center">66.12&#x000B1;46.2</td>
<td valign="top" align="center">25.69&#x000B1;11.3</td>
<td valign="top" align="center">239.38&#x000B1;387.1</td>
<td valign="top" align="center">67.93&#x000B1;39.1</td>
<td valign="top" align="center">94.1&#x000B1;71</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
<sec>
<title>3.3. sEMG/FMG regression for mycontrol</title>
<p>Table <xref ref-type="table" rid="T5">5</xref> shows the prediction accuracy obtained by each subject on one movement repetition (the nRMSE value showed is a mean of all the nRMSE obtained by the cross-validation). Figure <xref ref-type="fig" rid="F9">9</xref> shows the nRMSE values for all subjects. While the nRMSE values range from 0.13 to 0.21, in line with previous literature (Ravindra and Castellini, <xref ref-type="bibr" rid="B36">2014</xref>), no statistically significant difference in accuracy is apparent (one-way ANOVA <italic>p</italic> &#x0003E; 0.05).</p>
<table-wrap position="float" id="T5">
<label>Table 5</label>
<caption><p><bold>Prediction accuracy (nRMSE) obtained by Incremental Ridge Regression with Random Fourier Features when trained on FMG, sEMG and combined values</bold>.</p></caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th valign="top" align="left"><bold>Subject &#x00023;</bold></th>
<th valign="top" align="center"><bold>1</bold></th>
<th valign="top" align="center"><bold>2</bold></th>
<th valign="top" align="center"><bold>3</bold></th>
<th valign="top" align="center"><bold>4</bold></th>
<th valign="top" align="center"><bold>5</bold></th>
<th valign="top" align="center"><bold>6</bold></th>
<th valign="top" align="center"><bold>7</bold></th>
<th valign="top" align="center"><bold>8</bold></th>
<th valign="top" align="center"><bold>9</bold></th>
<th valign="top" align="center"><bold>10</bold></th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">FMG</td>
<td valign="top" align="center">0.17&#x000B1;0.016</td>
<td valign="top" align="center">0.1687&#x000B1;0.0173</td>
<td valign="top" align="center">0.1495&#x000B1;0.007</td>
<td valign="top" align="center">0.1636&#x000B1;0.011</td>
<td valign="top" align="center">0.1762&#x000B1;0.0087</td>
<td valign="top" align="center">0.173&#x000B1;0.0184</td>
<td valign="top" align="center">0.1728&#x000B1;0.0121</td>
<td valign="top" align="center">0.1893&#x000B1;0.0352</td>
<td valign="top" align="center">0.1548&#x000B1;0.0133</td>
<td valign="top" align="center">0.1803&#x000B1;0.0222</td>
</tr>
<tr>
<td valign="top" align="left">sEMG</td>
<td valign="top" align="center">0.1494&#x000B1;0.0138</td>
<td valign="top" align="center">0.1573&#x000B1;0.0175</td>
<td valign="top" align="center">0.1458&#x000B1;0.0123</td>
<td valign="top" align="center">0.2056&#x000B1;0.047</td>
<td valign="top" align="center">0.1673&#x000B1;0.0098</td>
<td valign="top" align="center">0.1857&#x000B1;0.0126</td>
<td valign="top" align="center">0.1736&#x000B1;0.0193</td>
<td valign="top" align="center">0.2037&#x000B1;0.0343</td>
<td valign="top" align="center">0.1346&#x000B1;0.0061</td>
<td valign="top" align="center">0.1801&#x000B1;0.045</td>
</tr>
<tr>
<td valign="top" align="left">Comb.</td>
<td valign="top" align="center">0.1649&#x000B1;0.0137</td>
<td valign="top" align="center">0.1608&#x000B1;0.0199</td>
<td valign="top" align="center">0.1385&#x000B1;0.0083</td>
<td valign="top" align="center">0.1595&#x000B1;0.0161</td>
<td valign="top" align="center">0.1636&#x000B1;0.0066</td>
<td valign="top" align="center">0.1658&#x000B1;0.0139</td>
<td valign="top" align="center">0.1736&#x000B1;0.0139</td>
<td valign="top" align="center">0.2054&#x000B1;0.0267</td>
<td valign="top" align="center">0.1367&#x000B1;0.0048</td>
<td valign="top" align="center">0.1526&#x000B1;0.013</td>
</tr>
</tbody>
</table>
</table-wrap>
<fig id="F9" position="float">
<label>Figure 9</label>
<caption><p><bold>Prediction accuracy obtained by FMG, sEMG and their combination</bold>.</p></caption>
<graphic xlink:href="fnbot-10-00017-g0009.tif"/>
</fig>
</sec>
<sec>
<title>3.4. User satisfaction</title>
<p>For the SUS, the total result of each subject and the mean score are presented in Table <xref ref-type="table" rid="T6">6</xref>. Notice that the higher the score, the more usable the user judged the device. In this survey, the statements that had the worst scores were &#x0201C;I think that I would need the support of a technical person to be able to use this device&#x0201D; and &#x0201C;I felt very confident using the device.&#x0201D;</p>
<table-wrap position="float" id="T6">
<label>Table 6</label>
<caption><p><bold>Subject&#x00027;s system usability total scores</bold>.</p></caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th valign="top" align="center"><bold>ID</bold></th>
<th valign="top" align="center"><bold>1</bold></th>
<th valign="top" align="center"><bold>2</bold></th>
<th valign="top" align="center"><bold>3</bold></th>
<th valign="top" align="center"><bold>4</bold></th>
<th valign="top" align="center"><bold>5</bold></th>
<th valign="top" align="center"><bold>6</bold></th>
<th valign="top" align="center"><bold>7</bold></th>
<th valign="top" align="center"><bold>8</bold></th>
<th valign="top" align="center"><bold>9</bold></th>
<th valign="top" align="center"><bold>10</bold></th>
<th valign="top" align="center"><bold>Mean</bold></th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="center">SUS</td>
<td valign="top" align="center">85</td>
<td valign="top" align="center">90</td>
<td valign="top" align="center">100</td>
<td valign="top" align="center">77.5</td>
<td valign="top" align="center">92.5</td>
<td valign="top" align="center">67.5</td>
<td valign="top" align="center">75</td>
<td valign="top" align="center">85</td>
<td valign="top" align="center">100</td>
<td valign="top" align="center">75</td>
<td valign="top" align="center">84.75</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>For the NASA TLX, the total result for each subscale of each subject and overall workload are shown in Table <xref ref-type="table" rid="T7">7</xref>. Here the highest the score, the more workload the user had, when using the device. A plot with average percentages of the workload by subscale is visible in Figure <xref ref-type="fig" rid="F10">10</xref>.</p>
<table-wrap position="float" id="T7">
<label>Table 7</label>
<caption><p><bold>NASA TLX workload percentages</bold>.</p></caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th valign="top" align="left"><bold>ID</bold></th>
<th valign="top" align="center"><bold>1</bold></th>
<th valign="top" align="center"><bold>2</bold></th>
<th valign="top" align="center"><bold>3</bold></th>
<th valign="top" align="center"><bold>4</bold></th>
<th valign="top" align="center"><bold>5</bold></th>
<th valign="top" align="center"><bold>6</bold></th>
<th valign="top" align="center"><bold>7</bold></th>
<th valign="top" align="center"><bold>8</bold></th>
<th valign="top" align="center"><bold>9</bold></th>
<th valign="top" align="center"><bold>10</bold></th>
<th valign="top" align="center"><bold>Mean</bold></th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Mental demand</td>
<td valign="top" align="center">66.66</td>
<td valign="top" align="center">19.04</td>
<td valign="top" align="center">9.52</td>
<td valign="top" align="center">14.28</td>
<td valign="top" align="center">23.8</td>
<td valign="top" align="center">28.57</td>
<td valign="top" align="center">9.52</td>
<td valign="top" align="center">14.28</td>
<td valign="top" align="center">4.76</td>
<td valign="top" align="center">9.52</td>
<td valign="top" align="center">20</td>
</tr>
<tr>
<td valign="top" align="left">Physical demand</td>
<td valign="top" align="center">33.33</td>
<td valign="top" align="center">23.8</td>
<td valign="top" align="center">14.28</td>
<td valign="top" align="center">14.28</td>
<td valign="top" align="center">23.8</td>
<td valign="top" align="center">23.8</td>
<td valign="top" align="center">9.52</td>
<td valign="top" align="center">14.28</td>
<td valign="top" align="center">4.76</td>
<td valign="top" align="center">76.19</td>
<td valign="top" align="center">23.8</td>
</tr>
<tr>
<td valign="top" align="left">Temporal demand</td>
<td valign="top" align="center">71.42</td>
<td valign="top" align="center">61.9</td>
<td valign="top" align="center">52.38</td>
<td valign="top" align="center">14.28</td>
<td valign="top" align="center">52.38</td>
<td valign="top" align="center">57.14</td>
<td valign="top" align="center">14.28</td>
<td valign="top" align="center">61.9</td>
<td valign="top" align="center">4.76</td>
<td valign="top" align="center">33.33</td>
<td valign="top" align="center">42.38</td>
</tr>
<tr>
<td valign="top" align="left">Performance</td>
<td valign="top" align="center">28.57</td>
<td valign="top" align="center">28.57</td>
<td valign="top" align="center">19.04</td>
<td valign="top" align="center">14.28</td>
<td valign="top" align="center">14.28</td>
<td valign="top" align="center">19.04</td>
<td valign="top" align="center">52.38</td>
<td valign="top" align="center">14.28</td>
<td valign="top" align="center">4.76</td>
<td valign="top" align="center">38.09</td>
<td valign="top" align="center">23.33</td>
</tr>
<tr>
<td valign="top" align="left">Effort</td>
<td valign="top" align="center">52.38</td>
<td valign="top" align="center">19.04</td>
<td valign="top" align="center">23.8</td>
<td valign="top" align="center">9.52</td>
<td valign="top" align="center">52.38</td>
<td valign="top" align="center">19.04</td>
<td valign="top" align="center">52.38</td>
<td valign="top" align="center">14.28</td>
<td valign="top" align="center">4.76</td>
<td valign="top" align="center">38.09</td>
<td valign="top" align="center">28.57</td>
</tr>
<tr>
<td valign="top" align="left">Frustration</td>
<td valign="top" align="center">19.04</td>
<td valign="top" align="center">14.28</td>
<td valign="top" align="center">4.76</td>
<td valign="top" align="center">19.04</td>
<td valign="top" align="center">23.8</td>
<td valign="top" align="center">9.52</td>
<td valign="top" align="center">9.52</td>
<td valign="top" align="center">9.52</td>
<td valign="top" align="center">4.76</td>
<td valign="top" align="center">14.28</td>
<td valign="top" align="center">12.85</td>
</tr>
<tr>
<td valign="top" align="left">Overall WL</td>
<td valign="top" align="center">45.2381</td>
<td valign="top" align="center">27.77</td>
<td valign="top" align="center">20.63</td>
<td valign="top" align="center">14.28</td>
<td valign="top" align="center">31.74</td>
<td valign="top" align="center">26.19</td>
<td valign="top" align="center">24.6</td>
<td valign="top" align="center">21.42</td>
<td valign="top" align="center">4.76</td>
<td valign="top" align="center">34.92</td>
<td valign="top" align="center">25.15</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<p><italic>(Subject &#x00023;9 actually gave a uniform scoring.)</italic></p>
</table-wrap-foot>
</table-wrap>
<fig id="F10" position="float">
<label>Figure 10</label>
<caption><p><bold>Workload percentage plot</bold>.</p></caption>
<graphic xlink:href="fnbot-10-00017-g0010.tif"/>
</fig>
<p>The first two surveys applied comprised suitable results with a usability score of almost 85% and an overall workload of 25%.</p>
<p>Finally, for the desirability survey proposed by Travis, two kinds of results were obtained, the first one using all the words chosen by the user in the first selection, and the second one considering only the 5 final selections. In order to have a different visualization, two word clouds have been created (Figure <xref ref-type="fig" rid="F11">11</xref>), where the bigger and darker the font is, the more often the word was selected.</p>
<fig id="F11" position="float">
<label>Figure 11</label>
<caption><p><bold>Word clouds from the results of the desirability survey</bold>. <bold>(A)</bold> First selection word cloud. <bold>(B)</bold> Final 5 words selection cloud.</p></caption>
<graphic xlink:href="fnbot-10-00017-g0011.tif"/>
</fig>
<p>Considering only the most common adjectives in the final selection, the device can be considered <italic>Simple, Intuitive, Easy to use, Familiar, Reliable</italic> and <italic>Stable</italic>. An important thing to mention about this last survey is that even though the instructions and the questions were oriented toward the device, some answers referred to the experiment performance. For instance, the adjective <italic>familiar</italic> was chosen in some cases because the subject had already performed other experiments with EMG sensors before taking part in this specific experiment.</p>
<p>To highlight the results of the user satisfaction surveys, a radial chart (Figure <xref ref-type="fig" rid="F12">12</xref>) was built, which separates the results in different categories (Low Workload Demand, Stability, Task Accomplishment, Interface, Easy to Use, Comfort and Setup) and represents the main features appreciated by the user. The figure for Low Workload Demand has been inverted on the scale to achieve better comparability with the other figures (i.e., Workload Demand is positively rated if being low). All of these categories can furthermore be separated in two kinds of classes: usability related features (Interface, Easy to Use, Comfort and Setup) and performance related features (Workload Demand, Stability and Task Accomplishment).</p>
<fig id="F12" position="float">
<label>Figure 12</label>
<caption><p><bold>Radial chart showing the user satisfaction surveys&#x00027; results summarized in different device features</bold>.</p></caption>
<graphic xlink:href="fnbot-10-00017-g0012.tif"/>
</fig>
</sec>
</sec>
<sec sec-type="discussion" id="s4">
<title>4. Discussion</title>
<p>This work had two main aims: to assess whether a wearable combined sEMG/FMG device would be accepted by human subjects using it, and to determine whether significant qualitative and quantitative differences could be observed between sEMG and FMG signals obtained during a simple experiment aimed at myocontrol.</p>
<sec>
<title>4.1. Acceptance of the device</title>
<p>Consider Section 3.4, in particular Figure <xref ref-type="fig" rid="F12">12</xref>. The results clearly show that the device, together with its user interface, posed no problems to the subjects using it, and even had some appeal. Even though the subjects involved in the experiment are not part of the potential user population (i.e., amputated subjects controlling a self-powered prosthesis), their opinions and impressions about the device are helpful for future improvements and corrections. The subjects uniformly reported that the device felt reliable and stable; that the setup was easy to use, simple and comfortable, with a low frustration rate; that the user interface was friendly, intuitive and well structured; and that the data acquisition still required a considerable amount of time (this aspect having the highest workload demand).</p>
<p>The keywords obtained in Travis&#x00027;s survey, the workloads obtained in the NASA TLX survey, and the successful performance reflected in the SUS test, already give hints about the usage risk of a possible future medical device. Of course, this cannot replace a thorough risk analysis and a widespread usability study. Furthermore, it must be remarked that the positive results obtained in the surveys could have been influenced by the subjects&#x00027; behaviors themselves, as explained by Travis. All in all, it is worthwhile to stress that no online experiment was performed in this study, therefore, from the user survey results, we can provide no conclusive results about either the performance of this device in general, or the usefulness of a combined sEMG/FMG approach in myocontrol.</p>
</sec>
<sec>
<title>4.2. Comparison of sEMG and FMG</title>
<p>In previous literature (Yungher et al., <xref ref-type="bibr" rid="B47">2011</xref>; Ravindra and Castellini, <xref ref-type="bibr" rid="B36">2014</xref>) it has been shown that FMG shows higher <italic>overall</italic> stability over time than sEMG, meaning that, e.g., the variance of its signals is lower than that of sEMG, while human subjects are engaged in repetitive, fatiguing tasks. This is probably due to the lower influence that muscle fatigue has on FMG signals, due to its nature. Now, from the qualitative/quantitative comparison of sEMG and FMG carried out in Sections 3.1 and 3.2, two statistically significant differences between the two approaches emerge, namely (a) that FMG signals are more stable over time <italic>during single movements too</italic>, and (b) that they generate better separated patterns in the input space. Most likely, (b) is a consequence of (a); we speculate that this difference might arise from the very nature of the sEMG signals, which exhibit noise due to the recruitment of motor units while keeping an isometric hand/wrist posture. Of course, FMG would not be affected by this problem. All things considered, it seems reasonable to claim that FMG signals are more stable than sEMG ones.</p>
<p>About pattern separateness: if a classification approach were to be used to enforce myocontrol using such signals, better pattern separability would definitely represent a further advantage of FMG with respect to sEMG; in the case of simultaneous and proportional control, however, it is not clear whether this is an advantage or not. This kind of control requires some way to understand not only what pattern the subject desires, but also how much force/torque is involved; distant and smaller clusters for the maximal activations might contain less information about this specific feature. In our case, the regression method used in Section 3.3 is trained on maximal and minimal activation signals only, whereas it predicts the intermediate activation values by non-linear interpolation. We are in no position at this time, to claim that FMG or sEMG is better in this case (and this is reflected in the non-stastically-significant accuracy results obtained by such method, see Table <xref ref-type="table" rid="T5">5</xref> again).</p>
<p>On a more qualitative side, we note that FMG, at least enforced using this cheap approach (that is, Force-Sensing Resistors), presents the drawback of being affected by hysteresis. Although the return to the resting state is apparent, this induces the FMG signals even to rise during the resting states, but not to come back exactly to zero or the previously measured resting states after a movement is performed. As opposed to this, sEMG signals remain almost at zero even when the user is not in the same initial position; this seems reasonable, since the resting phase involves no muscle activation. This problem can be countered by employing a smarter technique to gather FMG signals, for instance the capacitive approach, or (high-density) tactile sensing. Also, a fully-fledged, online FMG approach will need to take into account the inevitable artifacts generated by the arm/forearm movement (i.e., accelerations inducing pressure on the sensors) and those induced by touching the socket, bumping into objects, laying the stump on a table, etc.</p>
<p>What we can conclude, we believe beyond any reasonable doubt, is that sEMG and FMG can be miniaturized and employed in such a framework, and that they carry different kinds of information, leading to different behaviors and signal features. We speculate that a structured sensor-fusion approach (that is, deeper than simply stacking the signals as we have done in this work) might lead to a better exploitation of each modality&#x00027;s characteristics.</p>
<p>One last remark is in order about the cost of each approach. Apparently, FMG is up to two orders of magnitude cheaper than sEMG, but this is mainly due at this stage to (a) it being enforced through Force-Sensing Resistors, which might not live up to the expectations as previously remarked; and (b) the necessity, in the very end, to produce a <italic>medically certified</italic> FMG approach and device, which might dramatically raise its costs. Again, we believe that an <italic>integrated</italic> approach is the way ahead to improve myocontrol using this still novel technique alongside sEMG. To this aim, the assessment of the wearable sEMG/FMG device we carried out is promising, as it shows that at least the required electronic machinery can be embedded in an effective, light and acceptable device.</p>
</sec>
<sec>
<title>4.3. Conclusions and future work</title>
<p>In this article, we have described a wearable, integrated sEMG/FMG system, targeting myocontrol and human intent detection. The experiment we conducted endorses the system&#x00027;s high degree of usability, indicating that it has the potential to become an integrated medical product. Still, the autonomous mobility of about 11 h is restricted by the cell phone battery, thus recharging strategies during the patient&#x00027;s daily use or the deployment of a secondary device could be a solution for now. In near future, the development of a highly integrated, low energy system, where the phone serves only for teaching and displaying information, seems to be advisable. Additionally, we explored the application of FMG as a potential complement to sEMG and provided evidence that the two techniques can be integrated, but that a smart sensor fusion approach might be required to obtain the best results. Results from user satisfaction surveys presented in the paper give strong indication for the setup to be on the right track. In the near future, more experiments are planned to check the feasibility of mixed sEMG/FMG for online myocontrol, possibly down to the level of individual finger movements, and immersed in daily-life activities.</p>
</sec>
</sec>
<sec id="s5">
<title>Author contributions</title>
<p>System Design BV, MC, CC; Software Design MC, BV; Test setup and conduction of user Surveys ER, MC, CC; Analysis and Interpretation of data ER, CC; Drafting of manuscript MC, ER, BV; Internal Revision BV, CC; Critical Revision BV, CC, MC, ER; Final Approval MC, ER, BV, CC; Agreement on accountability by MC, ER, BC, CC.</p>
<sec>
<title>Conflict of interest statement</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
</sec>
</body>
<back>
<ack><p>The authors thank Mr. Miguel Neves of the DLR for designing and building the housings of the sensors. This work was partially supported by the DFG project &#x0201C;TACT_HAND: Improving control of prosthetic hands using tactile sensors and realistic machine learning&#x0201D; (Sachbeihilfe CA1389/1-1).</p>
</ack>
<ref-list>
<title>References</title>
<ref id="B1">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Amsuess</surname> <given-names>S.</given-names></name> <name><surname>Vujaklija</surname> <given-names>I.</given-names></name> <name><surname>Goebel</surname> <given-names>P.</given-names></name> <name><surname>Roche</surname> <given-names>A. D.</given-names></name> <name><surname>Graimann</surname> <given-names>B.</given-names></name> <name><surname>Aszmann</surname> <given-names>O. C.</given-names></name> <etal/></person-group>. (<year>2016</year>). <article-title>Context-dependent upper limb prosthesis control for natural and robust use</article-title>. <source>IEEE Trans. Neural Syst. Rehabil. Eng.</source> <volume>24</volume>, <fpage>744</fpage>&#x02013;<lpage>753</lpage>. <pub-id pub-id-type="doi">10.1109/TNSRE.2015.2454240</pub-id><pub-id pub-id-type="pmid">26173217</pub-id></citation>
</ref>
<ref id="B2">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Arjunan</surname> <given-names>S. P.</given-names></name> <name><surname>Kumar</surname> <given-names>D. K.</given-names></name></person-group> (<year>2010</year>). <article-title>Decoding subtle forearm flexions using fractal features of surface electromyogram from single and multiple sensors</article-title>. <source>J. Neuroeng. Rehabil.</source> <volume>7</volume>:<fpage>53</fpage>. <pub-id pub-id-type="doi">10.1186/1743-0003-7-53</pub-id><pub-id pub-id-type="pmid">20964863</pub-id></citation>
</ref>
<ref id="B3">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Atzori</surname> <given-names>M.</given-names></name> <name><surname>Gijsberts</surname> <given-names>A.</given-names></name> <name><surname>Castellini</surname> <given-names>C.</given-names></name> <name><surname>Caputo</surname> <given-names>B.</given-names></name> <name><surname>Mittaz Hager</surname> <given-names>A.-G.</given-names></name> <name><surname>Elsig</surname> <given-names>S.</given-names></name> <etal/></person-group>. (<year>2014</year>). <article-title>Electromyography data for non-invasive naturally-controlled robotic hand prostheses</article-title>. <source>Sci. Data</source> <volume>1</volume>:<fpage>140053</fpage>. <pub-id pub-id-type="doi">10.1038/sdata.2014.53</pub-id><pub-id pub-id-type="pmid">25977804</pub-id></citation>
</ref>
<ref id="B4">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Baspinar</surname> <given-names>U.</given-names></name> <name><surname>Varol</surname> <given-names>H. S.</given-names></name> <name><surname>Senyurek</surname> <given-names>V. Y.</given-names></name></person-group> (<year>2013</year>). <article-title>Performance comparison of artificial neural network and Gaussian mixture model in classifying hand motions by using sEMG signals</article-title>. <source>Biocybern. Biomed. Eng.</source> <volume>33</volume>, <fpage>33</fpage>&#x02013;<lpage>45</lpage>. <pub-id pub-id-type="doi">10.1016/S0208-5216(13)70054-8</pub-id></citation>
</ref>
<ref id="B5">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Biddiss</surname> <given-names>E.</given-names></name> <name><surname>Chau</surname> <given-names>T.</given-names></name></person-group> (<year>2007</year>). <article-title>Upper-limb prosthetics: critical factors in device abandonment</article-title>. <source>Am. J. Phys. Med. Rehabil.</source> <volume>86</volume>, <fpage>977</fpage>&#x02013;<lpage>987</lpage>. <pub-id pub-id-type="doi">10.1097/PHM.0b013e3181587f6c</pub-id><pub-id pub-id-type="pmid">18090439</pub-id></citation>
</ref>
<ref id="B6">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Brooke</surname> <given-names>J.</given-names></name></person-group> (<year>1996</year>). <article-title>SUS: A &#x0201C;quick and dirty&#x0201D; usability scale</article-title>, in <source>Usability Evaluation in Industry</source>, eds <person-group person-group-type="editor"><name><surname>Jordan</surname> <given-names>P. W.</given-names></name> <name><surname>Thomas</surname> <given-names>B.</given-names></name> <name><surname>Weerdmeester</surname> <given-names>B. A.</given-names></name> <name><surname>McClelland</surname> <given-names>A. L.</given-names></name></person-group> (<publisher-loc>London</publisher-loc>: <publisher-name>Taylor &#x00026; Francis</publisher-name>), <fpage>189</fpage>&#x02013;<lpage>194</lpage>.</citation>
</ref>
<ref id="B7">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Brunelli</surname> <given-names>D.</given-names></name> <name><surname>Tadesse</surname> <given-names>A. M.</given-names></name> <name><surname>Vodermayer</surname> <given-names>B.</given-names></name> <name><surname>Nowak</surname> <given-names>M.</given-names></name> <name><surname>Castellini</surname> <given-names>C.</given-names></name></person-group> (<year>2015</year>). <article-title>Low-cost wearable multichannel surface EMG acquisition for prosthetic hand control</article-title>, in <source>2015 6th International Workshop on Advances in Sensors and Interfaces (IWASI)</source> (<publisher-loc>Gallipoli: IEEE</publisher-loc>), <fpage>94</fpage>&#x02013;<lpage>99</lpage>. <pub-id pub-id-type="doi">10.1109/IWASI.2015.7184964</pub-id></citation>
</ref>
<ref id="B8">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bunderson</surname> <given-names>N. E.</given-names></name> <name><surname>Kuiken</surname> <given-names>T. A.</given-names></name></person-group> (<year>2012</year>). <article-title>Quantification of feature space changes with experience during electromyogram pattern recognition control</article-title>. <source>IEEE Trans. Neural Syst. Rehabil. Eng.</source> <volume>20</volume>, <fpage>239</fpage>&#x02013;<lpage>246</lpage>. <pub-id pub-id-type="doi">10.1109/TNSRE.2011.2182525</pub-id><pub-id pub-id-type="pmid">22262686</pub-id></citation>
</ref>
<ref id="B9">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Castellini</surname> <given-names>C.</given-names></name> <name><surname>Artemiadis</surname> <given-names>P.</given-names></name> <name><surname>Wininger</surname> <given-names>M.</given-names></name> <name><surname>Ajoudani</surname> <given-names>A.</given-names></name> <name><surname>Alimusaj</surname> <given-names>M.</given-names></name> <name><surname>Bicchi</surname> <given-names>A.</given-names></name> <etal/></person-group>. (<year>2014</year>). <article-title>Proceedings of the first workshop on peripheral machine interfaces: going beyond traditional surface electromyography</article-title>. <source>Front. Neurorobot.</source> <volume>8</volume>:<fpage>22</fpage>. <pub-id pub-id-type="doi">10.3389/fnbot.2014.00022</pub-id><pub-id pub-id-type="pmid">25177292</pub-id></citation>
</ref>
<ref id="B10">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Castellini</surname> <given-names>C.</given-names></name> <name><surname>Gruppioni</surname> <given-names>E.</given-names></name> <name><surname>Davalli</surname> <given-names>A.</given-names></name> <name><surname>Sandini</surname> <given-names>G.</given-names></name></person-group> (<year>2009</year>). <article-title>Fine detection of grasp force and posture by amputees via surface electromyography</article-title>. <source>J. Physiol. (Paris)</source> <volume>103</volume>, <fpage>255</fpage>&#x02013;<lpage>262</lpage>. <pub-id pub-id-type="doi">10.1016/j.jphysparis.2009.08.008</pub-id><pub-id pub-id-type="pmid">19665563</pub-id></citation>
</ref>
<ref id="B11">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Castellini</surname> <given-names>C.</given-names></name> <name><surname>Ravindra</surname> <given-names>V.</given-names></name></person-group> (<year>2014</year>). <article-title>A wearable low-cost device based upon force-sensing resistors to detect single-finger forces</article-title>, in <source>5th IEEE RAS/EMBS International Conference on Biomedical Robotics and Biomechatronics</source> (<publisher-loc>S&#x000E3;o Paulo: IEEE</publisher-loc>), <fpage>199</fpage>&#x02013;<lpage>203</lpage>. <pub-id pub-id-type="doi">10.1109/BIOROB.2014.6913776</pub-id></citation>
</ref>
<ref id="B12">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Castellini</surname> <given-names>C.</given-names></name> <name><surname>van der Smagt</surname> <given-names>P.</given-names></name></person-group> (<year>2009</year>). <article-title>Surface EMG in advanced hand prosthetics</article-title>. <source>Biol. Cybern.</source> <volume>100</volume>, <fpage>35</fpage>&#x02013;<lpage>47</lpage>. <pub-id pub-id-type="doi">10.1007/s00422-008-0278-1</pub-id><pub-id pub-id-type="pmid">19015872</pub-id></citation>
</ref>
<ref id="B13">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Castellini</surname> <given-names>C.</given-names></name> <name><surname>van der Smagt</surname> <given-names>P.</given-names></name></person-group> (<year>2013</year>). <article-title>Evidence of muscle synergies during human grasping</article-title>. <source>Biol. Cybern.</source> <volume>107</volume>, <fpage>233</fpage>&#x02013;<lpage>245</lpage>. <pub-id pub-id-type="doi">10.1007/s00422-013-0548-4</pub-id><pub-id pub-id-type="pmid">23370962</pub-id></citation>
</ref>
<ref id="B14">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Cho</surname> <given-names>E.</given-names></name> <name><surname>Chen</surname> <given-names>R.</given-names></name> <name><surname>Merhi</surname> <given-names>L.-K.</given-names></name> <name><surname>Xiao</surname> <given-names>Z.</given-names></name> <name><surname>Pousett</surname> <given-names>B.</given-names></name> <name><surname>Menon</surname> <given-names>C.</given-names></name></person-group> (<year>2016</year>). <article-title>Force myography to control robotic upper extremity prostheses: a feasibility study</article-title>. <source>Front. Bioeng. Biotechnol.</source> <volume>4</volume>:<fpage>18</fpage>. <pub-id pub-id-type="doi">10.3389/fbioe.2016.00018</pub-id><pub-id pub-id-type="pmid">27014682</pub-id></citation>
</ref>
<ref id="B15">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Cipriani</surname> <given-names>C.</given-names></name> <name><surname>Antfolk</surname> <given-names>C.</given-names></name> <name><surname>Controzzi</surname> <given-names>M.</given-names></name> <name><surname>Lundborg</surname> <given-names>G.</given-names></name> <name><surname>Rosen</surname> <given-names>B.</given-names></name> <name><surname>Carrozza</surname> <given-names>M.</given-names></name> <etal/></person-group>. (<year>2011a</year>). <article-title>Online myoelectric control of a dexterous hand prosthesis by transradial amputees</article-title>. <source>IEEE Trans. Neural Syst. Rehabil. Eng.</source> <volume>19</volume>, <fpage>260</fpage>&#x02013;<lpage>270</lpage>. <pub-id pub-id-type="doi">10.1109/TNSRE.2011.2108667</pub-id><pub-id pub-id-type="pmid">21292599</pub-id></citation>
</ref>
<ref id="B16">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Cipriani</surname> <given-names>C.</given-names></name> <name><surname>Sassu</surname> <given-names>R.</given-names></name> <name><surname>Controzzi</surname> <given-names>M.</given-names></name> <name><surname>Kanitz</surname> <given-names>G.</given-names></name> <name><surname>Carrozza</surname> <given-names>M. C.</given-names></name></person-group> (<year>2011b</year>). <article-title>Preliminary study on the influence of inertia and weight of the prosthesis on the EMG pattern recognition robustness</article-title>, in <source>Proceedings of the 2011 MyoElectric Controls/Powered Prosthetics Symposium</source> (<publisher-loc>Fredericton, NB</publisher-loc>).</citation>
</ref>
<ref id="B17">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Cram</surname> <given-names>J.</given-names></name> <name><surname>Kasman</surname> <given-names>G.</given-names></name></person-group> (<year>2010</year>). <article-title>The basics of surface electromyography</article-title>, in <source>Cram&#x00027;s Introduction To Surface Electromyography</source>, <edition>2nd Edn</edition>., ed <person-group person-group-type="editor"><name><surname>Criswell</surname> <given-names>E.</given-names></name></person-group> (<publisher-loc>Sudbury, MA</publisher-loc>: <publisher-name>Jones and Bartlett Publishers</publisher-name>), <fpage>1</fpage>&#x02013;<lpage>163</lpage>.</citation>
</ref>
<ref id="B18">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fang</surname> <given-names>Y.</given-names></name> <name><surname>Hettiarachchi</surname> <given-names>N.</given-names></name> <name><surname>Zhou</surname> <given-names>D.</given-names></name> <name><surname>Liu</surname> <given-names>H.</given-names></name></person-group> (<year>2015</year>). <article-title>Multi-modal sensing techniques for interfacing hand prostheses: a review</article-title>. <source>IEEE Sens. J.</source> <volume>15</volume>, <fpage>6065</fpage>&#x02013;<lpage>6076</lpage>. <pub-id pub-id-type="doi">10.1109/JSEN.2015.2450211</pub-id></citation>
</ref>
<ref id="B19">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fisher</surname> <given-names>R. A.</given-names></name></person-group> (<year>1936</year>). <article-title>The use of multiple measurements in taxonomic problems</article-title>. <source>Ann. Eugen.</source> <volume>7</volume>, <fpage>179</fpage>&#x02013;<lpage>188</lpage>. <pub-id pub-id-type="doi">10.1111/j.1469-1809.1936.tb02137.x</pub-id></citation>
</ref>
<ref id="B20">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fougner</surname> <given-names>A.</given-names></name> <name><surname>Scheme</surname> <given-names>E.</given-names></name> <name><surname>Chan</surname> <given-names>A. D. C.</given-names></name> <name><surname>Englehart</surname> <given-names>K.</given-names></name> <name><surname>Stavdahl</surname> <given-names>O.</given-names></name></person-group> (<year>2011</year>). <article-title>Resolving the limb position effect in myoelectric pattern recognition</article-title>. <source>IEEE Trans. Neural Syst. Rehabil. Eng.</source> <volume>19</volume>, <fpage>644</fpage>&#x02013;<lpage>651</lpage>. <pub-id pub-id-type="doi">10.1109/TNSRE.2011.2163529</pub-id><pub-id pub-id-type="pmid">21846608</pub-id></citation>
</ref>
<ref id="B21">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gijsberts</surname> <given-names>A.</given-names></name> <name><surname>Bohra</surname> <given-names>R.</given-names></name> <name><surname>Sierra Gonz&#x000E1;lez</surname> <given-names>D.</given-names></name> <name><surname>Werner</surname> <given-names>A.</given-names></name> <name><surname>Nowak</surname> <given-names>M.</given-names></name> <name><surname>Caputo</surname> <given-names>B.</given-names></name> <etal/></person-group>. (<year>2014</year>). <article-title>Stable myoelectric control of a hand prosthesis using non-linear incremental learning</article-title>. <source>Front. Neurorobot.</source> <volume>8</volume>:<fpage>8</fpage>. <pub-id pub-id-type="doi">10.3389/fnbot.2014.00008</pub-id><pub-id pub-id-type="pmid">24616697</pub-id></citation>
</ref>
<ref id="B22">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Biryukova</surname> <given-names>E. V.</given-names></name> <name><surname>Yourovskaya</surname> <given-names>V. Z.</given-names></name></person-group> (<year>1994</year>). <article-title>A model of human hand dynamics</article-title>, in <source>Advances in the Biomechanics of the Hand and Wrist.</source> <volume>Vol. 256</volume>, eds <person-group person-group-type="editor"><name><surname>Schuind</surname> <given-names>F.</given-names></name> <name><surname>An</surname> <given-names>K. N.</given-names></name> <name><surname>Cooney</surname> <given-names>W. P.</given-names> <suffix>III</suffix></name> <name><surname>Garcia-Elias</surname> <given-names>M.</given-names></name></person-group> (<publisher-name>Springer</publisher-name>), <fpage>107</fpage>&#x02013;<lpage>122</lpage>.</citation>
</ref>
<ref id="B23">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Herrmann</surname> <given-names>S.</given-names></name> <name><surname>Buchenrieder</surname> <given-names>K.</given-names></name></person-group> (<year>2010</year>). <article-title>Fusion of myoelectric and near-infrared signals for prostheses control</article-title>, in <source>Proceedings of the 4th International Convention on Rehabilitation Engineering</source> &#x00026; <italic>Assistive Technology, (Singapore Therapeutic, Assistive and Rehabilitative Technologies (START) Centre), iCREATe &#x00027;10</italic> (<publisher-loc>Shanghai</publisher-loc>), <fpage>54:1</fpage>&#x02013;<lpage>54:4</lpage>.</citation>
</ref>
<ref id="B24">
<citation citation-type="web"><person-group person-group-type="author"><collab>Interlink Electronics</collab></person-group> (<year>2014</year>). <source>FSR Integration Guide</source>. Available online at: <ext-link ext-link-type="uri" xlink:href="http://www.interlinkelectronics.com/FSR400short.php">http://www.interlinkelectronics.com/FSR400short.php</ext-link> [Online]. (Accessed February 15, 2016).</citation>
</ref>
<ref id="B25">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jiang</surname> <given-names>N.</given-names></name> <name><surname>Dosen</surname> <given-names>S.</given-names></name> <name><surname>M&#x000FC;ller</surname> <given-names>K.-R.</given-names></name> <name><surname>Farina</surname> <given-names>D.</given-names></name></person-group> (<year>2012a</year>). <article-title>Myoelectric control of artificial limbs - is there a need to change focus?</article-title> <source>IEEE Signal Process. Magazine</source> <volume>29</volume>, <fpage>148</fpage>&#x02013;<lpage>152</lpage>.</citation>
</ref>
<ref id="B26">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jiang</surname> <given-names>N.</given-names></name> <name><surname>Vest-Nielsen</surname> <given-names>J.</given-names></name> <name><surname>Muceli</surname> <given-names>S.</given-names></name> <name><surname>Farina</surname> <given-names>D.</given-names></name></person-group> (<year>2012b</year>). <article-title>EMG-based simultaneous and proportional estimation of wrist/hand kinematics in uni-lateral trans-radial amputees</article-title>. <source>J. Neuroeng. Rehabil.</source> <volume>9</volume>:<fpage>42</fpage>. <pub-id pub-id-type="doi">10.1186/1743-0003-9-42</pub-id><pub-id pub-id-type="pmid">22742707</pub-id></citation>
</ref>
<ref id="B27">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Khushaba</surname> <given-names>R. N.</given-names></name> <name><surname>Al-Jumaily</surname> <given-names>A.</given-names></name> <name><surname>Al-Ani</surname> <given-names>A.</given-names></name></person-group> (<year>2009</year>). <article-title>Evolutionary fuzzy discriminant analysis feature projection technique in myoelectric control</article-title>. <source>Patt. Recogn. Lett.</source> <volume>30</volume>, <fpage>699</fpage>&#x02013;<lpage>707</lpage>. <pub-id pub-id-type="doi">10.1016/j.patrec.2009.02.004</pub-id></citation>
</ref>
<ref id="B28">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lobo-Prat</surname> <given-names>J.</given-names></name> <name><surname>Kooren</surname> <given-names>P. N.</given-names></name> <name><surname>Stienen</surname> <given-names>A. H.</given-names></name> <name><surname>Herder</surname> <given-names>J. L.</given-names></name> <name><surname>Koopman</surname> <given-names>B. F.</given-names></name> <name><surname>Veltink</surname> <given-names>P. H.</given-names></name></person-group> (<year>2014</year>). <article-title>Non-invasive control interfaces for intention detection in active movement-assistive devices</article-title>. <source>J. Neuroeng. Rehabil.</source> <volume>11</volume>:<fpage>168</fpage>. <pub-id pub-id-type="doi">10.1186/1743-0003-11-168</pub-id><pub-id pub-id-type="pmid">25516421</pub-id></citation>
</ref>
<ref id="B29">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Merletti</surname> <given-names>R.</given-names></name> <name><surname>Aventaggiato</surname> <given-names>M.</given-names></name> <name><surname>Botter</surname> <given-names>A.</given-names></name> <name><surname>Holobar</surname> <given-names>A.</given-names></name> <name><surname>Marateb</surname> <given-names>H.</given-names></name> <name><surname>Vieira</surname> <given-names>T.</given-names></name></person-group> (<year>2011a</year>). <article-title>Advances in surface EMG: recent progress in detection and processing techniques</article-title>. <source>Crit. Rev. Biomed. Eng.</source> <volume>38</volume>, <fpage>305</fpage>&#x02013;<lpage>345</lpage>. <pub-id pub-id-type="doi">10.1615/CritRevBiomedEng.v38.i4.10</pub-id><pub-id pub-id-type="pmid">21133837</pub-id></citation>
</ref>
<ref id="B30">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Merletti</surname> <given-names>R.</given-names></name> <name><surname>Botter</surname> <given-names>A.</given-names></name> <name><surname>Cescon</surname> <given-names>C.</given-names></name> <name><surname>Minetto</surname> <given-names>M.</given-names></name> <name><surname>Vieira</surname> <given-names>T.</given-names></name></person-group> (<year>2011b</year>). <article-title>Advances in surface EMG: recent progress in clinical research applications</article-title>. <source>Crit. Rev. Biomed. Eng.</source> <volume>38</volume>, <fpage>347</fpage>&#x02013;<lpage>379</lpage>. <pub-id pub-id-type="doi">10.1615/CritRevBiomedEng.v38.i4.20</pub-id><pub-id pub-id-type="pmid">21133838</pub-id></citation>
</ref>
<ref id="B31">
<citation citation-type="book"><person-group person-group-type="author"><collab>NASA</collab></person-group> (<year>1986</year>). <source>NASA TASK LOAD INDEX (TLX) v 1.0 Paper and Pencil Package</source>. <publisher-loc>Moffett Field, CA</publisher-loc>: <publisher-name>Human Performance Research Group, NASA Ames Research Center</publisher-name>.</citation>
</ref>
<ref id="B32">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Nielsen</surname> <given-names>J. L.</given-names></name> <name><surname>Holmgaard</surname> <given-names>S.</given-names></name> <name><surname>Jiang</surname> <given-names>N.</given-names></name> <name><surname>Englehart</surname> <given-names>K. B.</given-names></name> <name><surname>Farina</surname> <given-names>D.</given-names></name> <name><surname>Parker</surname> <given-names>P. A.</given-names></name></person-group> (<year>2011</year>). <article-title>Simultaneous and proportional force estimation for multifunction myoelectric prostheses using mirrored bilateral training</article-title>. <source>IEEE Trans. Biomed. Eng.</source> <volume>58</volume>, <fpage>681</fpage>&#x02013;<lpage>688</lpage>. <pub-id pub-id-type="doi">10.1109/TBME.2010.2068298</pub-id><pub-id pub-id-type="pmid">20729161</pub-id></citation>
</ref>
<ref id="B33">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Oskoei</surname> <given-names>M. A.</given-names></name> <name><surname>Hu</surname> <given-names>H.</given-names></name></person-group> (<year>2007</year>). <article-title>Myoelectric control systems&#x02014;a survey</article-title>. <source>Biomed. Signal Proc. Control</source> <volume>2</volume>, <fpage>275</fpage>&#x02013;<lpage>294</lpage>. <pub-id pub-id-type="doi">10.1016/j.bspc.2007.07.009</pub-id></citation>
</ref>
<ref id="B34">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Peerdeman</surname> <given-names>B.</given-names></name> <name><surname>Boere</surname> <given-names>D.</given-names></name> <name><surname>Witteveen</surname> <given-names>H.</given-names></name> <name><surname>in&#x00027;t Veld</surname> <given-names>R. H.</given-names></name> <name><surname>Hermens</surname> <given-names>H.</given-names></name> <name><surname>Stramigioli</surname> <given-names>S.</given-names></name> <etal/></person-group>. (<year>2011</year>). <article-title>Myoelectric forearm prostheses: state of the art from a user-centered perspective</article-title>. <source>J. Rehabil. Res. Dev.</source> <volume>48</volume>, <fpage>719</fpage>&#x02013;<lpage>738</lpage>. <pub-id pub-id-type="doi">10.1682/JRRD.2010.08.0161</pub-id><pub-id pub-id-type="pmid">21938658</pub-id></citation>
</ref>
<ref id="B35">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Phillips</surname> <given-names>S. L.</given-names></name> <name><surname>Craelius</surname> <given-names>W.</given-names></name></person-group> (<year>2005</year>). <article-title>Residual kinetic imaging: a versatile interface for prosthetic control</article-title>. <source>Robotica</source> <volume>23</volume>, <fpage>277</fpage>&#x02013;<lpage>282</lpage>. <pub-id pub-id-type="doi">10.1017/S0263574704001298</pub-id></citation>
</ref>
<ref id="B36">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ravindra</surname> <given-names>V.</given-names></name> <name><surname>Castellini</surname> <given-names>C.</given-names></name></person-group> (<year>2014</year>). <article-title>A comparative analysis of three non-invasive human-machine interfaces for the disabled</article-title>. <source>Front. Neurorobot.</source> <volume>8</volume>:<fpage>24</fpage>. <pub-id pub-id-type="doi">10.3389/fnbot.2014.00024</pub-id><pub-id pub-id-type="pmid">25386135</pub-id></citation>
</ref>
<ref id="B37">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Rossini</surname> <given-names>L.</given-names></name> <name><surname>Rossini</surname> <given-names>P. M.</given-names></name></person-group> (<year>2010</year>). <article-title>Combining ENG and EEG integrated analysis for better sensitivity and specificity of neuroprosthesis operations</article-title>, in <source>2010 Annual International Conference of the IEEE Engineering in Medicine and Biology</source> (<publisher-loc>Buenos Aires</publisher-loc>: <publisher-name>IEEE</publisher-name>), <fpage>134</fpage>&#x02013;<lpage>137</lpage>. <pub-id pub-id-type="doi">10.1109/IEMBS.2010.5627402</pub-id></citation>
</ref>
<ref id="B38">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Scheme</surname> <given-names>E.</given-names></name> <name><surname>Fougner</surname> <given-names>A.</given-names></name> <name><surname>Stavdahl</surname> <given-names>&#x000D8;.</given-names></name> <name><surname>Chan</surname> <given-names>A. D. C.</given-names></name> <name><surname>Englehart</surname> <given-names>K.</given-names></name></person-group> (<year>2010</year>). <article-title>Examining the adverse effects of limb position on pattern recognition based myoelectric control</article-title>, in <source>2010 Annual International Conference of the IEEE Engineering in Medicine and Biology</source> (<publisher-loc>Buenos Aires</publisher-loc>: <publisher-name>IEEE</publisher-name>), <fpage>6337</fpage>&#x02013;<lpage>6340</lpage>. <pub-id pub-id-type="doi">10.1109/IEMBS.2010.5627638</pub-id></citation>
</ref>
<ref id="B39">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sebelius</surname> <given-names>F. C. P.</given-names></name> <name><surname>Ros&#x000E9;n</surname> <given-names>B. N.</given-names></name> <name><surname>Lundborg</surname> <given-names>G. N.</given-names></name></person-group> (<year>2005</year>). <article-title>Refined myoelectric control in below-elbow amputees using artificial neural networks and a data glove</article-title>. <source>J. Hand Surg.</source> <volume>30A</volume>, <fpage>780</fpage>&#x02013;<lpage>789</lpage>. <pub-id pub-id-type="doi">10.1016/j.jhsa.2005.01.002</pub-id></citation>
</ref>
<ref id="B40">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sierra Gonz&#x000E1;lez</surname> <given-names>D.</given-names></name> <name><surname>Castellini</surname> <given-names>C.</given-names></name></person-group> (<year>2013</year>). <article-title>A realistic implementation of ultrasound imaging as a human-machine interface for upper-limb amputees</article-title>. <source>Front. Neurorobot.</source> <volume>7</volume>:<fpage>17</fpage>. <pub-id pub-id-type="doi">10.3389/fnbot.2013.00017</pub-id><pub-id pub-id-type="pmid">24155719</pub-id></citation>
</ref>
<ref id="B41">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Strazzulla</surname> <given-names>I.</given-names></name> <name><surname>Nowak</surname> <given-names>M.</given-names></name> <name><surname>Controzzi</surname> <given-names>M.</given-names></name> <name><surname>Cipriani</surname> <given-names>C.</given-names></name> <name><surname>Castellini</surname> <given-names>C.</given-names></name></person-group> (<year>2016</year>). <article-title>Online bimanual manipulation using surface electromyography and incremental learning</article-title>. <source>IEEE Trans. Neural Syst. Rehabil. Eng.</source> <pub-id pub-id-type="doi">10.1109/TNSRE.2016.2554884</pub-id>. [Epub ahead of print].</citation>
</ref>
<ref id="B42">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Tenore</surname> <given-names>F.</given-names></name> <name><surname>Ramos</surname> <given-names>A.</given-names></name> <name><surname>Fahmy</surname> <given-names>A.</given-names></name> <name><surname>Acharya</surname> <given-names>S.</given-names></name> <name><surname>Etienne-Cummings</surname> <given-names>R.</given-names></name> <name><surname>Thakor</surname> <given-names>N. V.</given-names></name></person-group> (<year>2007</year>). <article-title>Towards the control of individual fingers of a prosthetic hand using surface EMG signals</article-title>, in <source>Proceedings of the 29th Annual International Conference of the IEEE EMBS</source> (<publisher-loc>Lyon</publisher-loc>), <fpage>6146</fpage>&#x02013;<lpage>6149</lpage>.</citation>
</ref>
<ref id="B43">
<citation citation-type="web"><person-group person-group-type="author"><name><surname>Travis</surname> <given-names>D.</given-names></name></person-group> (<year>2008</year>). <source>Measuring Satisfaction: Beyond the Usability Questionnaire</source>. Available online at: <ext-link ext-link-type="uri" xlink:href="http://www.userfocus.co.uk/articles/satisfaction.html">http://www.userfocus.co.uk/articles/satisfaction.html</ext-link> [Online]. (Accessed June 10, 2016).</citation>
</ref>
<ref id="B44">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wininger</surname> <given-names>M.</given-names></name> <name><surname>Kim</surname> <given-names>N. H.</given-names></name> <name><surname>Craelius</surname> <given-names>W.</given-names></name></person-group> (<year>2008</year>). <article-title>Pressure signature of forearm as predictor of grip force</article-title>. <source>J. Rehabil. Res. Dev.</source> <volume>45</volume>, <fpage>883</fpage>&#x02013;<lpage>892</lpage>. <pub-id pub-id-type="doi">10.1682/JRRD.2007.11.0187</pub-id><pub-id pub-id-type="pmid">19009474</pub-id></citation>
</ref>
<ref id="B45">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yang</surname> <given-names>D.</given-names></name> <name><surname>Jiang</surname> <given-names>L.</given-names></name> <name><surname>Huang</surname> <given-names>Q.</given-names></name> <name><surname>Liu</surname> <given-names>R.</given-names></name> <name><surname>Liu</surname> <given-names>H.</given-names></name></person-group> (<year>2014</year>). <article-title>Experimental study of an EMG-controlled 5-dof anthropomorphic prosthetic hand for motion restoration</article-title>. <source>J. Intell. Robot. Syst.</source> <volume>76</volume>, <fpage>427</fpage>&#x02013;<lpage>441</lpage>. <pub-id pub-id-type="doi">10.1007/s10846-014-0037-6</pub-id></citation>
</ref>
<ref id="B46">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Young</surname> <given-names>A. J.</given-names></name> <name><surname>Hargrove</surname> <given-names>L. J.</given-names></name> <name><surname>Kuiken</surname> <given-names>T. A.</given-names></name></person-group> (<year>2012</year>). <article-title>Improving myoelectric pattern recognition robustness to electrode shift by changing interelectrode distance and electrode configuration</article-title>. <source>IEEE Trans. Biomed. Eng.</source> <volume>59</volume>, <fpage>645</fpage>&#x02013;<lpage>652</lpage>. <pub-id pub-id-type="doi">10.1109/TBME.2011.2177662</pub-id><pub-id pub-id-type="pmid">22147289</pub-id></citation>
</ref>
<ref id="B47">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yungher</surname> <given-names>D.</given-names></name> <name><surname>Wininger</surname> <given-names>M.</given-names></name> <name><surname>Baar</surname> <given-names>W.</given-names></name> <name><surname>Craelius</surname> <given-names>W.</given-names></name> <name><surname>Threlkeld</surname> <given-names>A.</given-names></name></person-group> (<year>2011</year>). <article-title>Surface muscle pressure as a means of active and passive behavior of muscles during gait</article-title>. <source>Med. Eng. Phys.</source> <volume>33</volume>, <fpage>464</fpage>&#x02013;<lpage>471</lpage>. <pub-id pub-id-type="doi">10.1016/j.medengphy.2010.11.012</pub-id></citation>
</ref>
</ref-list>
</back>
</article>
