<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" article-type="review-article" dtd-version="2.3" xml:lang="EN">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Neurol.</journal-id>
<journal-title>Frontiers in Neurology</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Neurol.</abbrev-journal-title>
<issn pub-type="epub">1664-2295</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fneur.2025.1608651</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Neurology</subject>
<subj-group>
<subject>Mini Review</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Rediscovering the carotid pulse: unlocking hidden insights in the era of AI-driven healthcare</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes">
<name><surname>Ben-Pazi</surname> <given-names>Hilla</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="corresp" rid="c001"><sup>&#x002A;</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/263512/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Jhashan</surname> <given-names>Shady</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Salame</surname> <given-names>Haill</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Cohen</surname> <given-names>Hillit</given-names></name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
<role content-type="https://credit.niso.org/contributor-roles/software/"/>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Matot</surname> <given-names>Idit</given-names></name>
<xref ref-type="aff" rid="aff4"><sup>4</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Pazi</surname> <given-names>Meron Ben</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Kirma</surname> <given-names>Yaniv</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Elmaliach</surname> <given-names>Lior</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Lavi</surname> <given-names>Yair</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Mintz</surname> <given-names>Pnina</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Corvaja</surname> <given-names>Nicola</given-names></name>
<xref ref-type="aff" rid="aff5"><sup>5</sup></xref>
<xref ref-type="aff" rid="aff6"><sup>6</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Dvir</surname> <given-names>Danny</given-names></name>
<xref ref-type="aff" rid="aff7"><sup>7</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Danenberg</surname> <given-names>Haim</given-names></name>
<xref ref-type="aff" rid="aff8"><sup>8</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Ribo</surname> <given-names>Marc</given-names></name>
<xref ref-type="aff" rid="aff9"><sup>9</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/471894/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
</contrib-group>
<aff id="aff1"><sup>1</sup><institution>Avertto Medical LTD</institution>, <addr-line>Aderet</addr-line>, <country>Israel</country></aff>
<aff id="aff2"><sup>2</sup><institution>Department of Neurosurgery, Galilee Medical Center</institution>, <addr-line>Nahariya</addr-line>, <country>Israel</country></aff>
<aff id="aff3"><sup>3</sup><institution>Department of Cardiac Surgery, Sheba Medical Center</institution>, <addr-line>Ramat Gan</addr-line>, <country>Israel</country></aff>
<aff id="aff4"><sup>4</sup><institution>Department of Anesthesiology and Critical Care and Pain, Tel Aviv Medical Center</institution>, <addr-line>Tel Aviv</addr-line>, <country>Israel</country></aff>
<aff id="aff5"><sup>5</sup><institution>Interventional Cardiology, New York-Presbyterian Hospital</institution>, <addr-line>New York, NY</addr-line>, <country>United States</country></aff>
<aff id="aff6"><sup>6</sup><institution>Columbia University Irving Medical Center</institution>, <addr-line>New York, NY</addr-line>, <country>United States</country></aff>
<aff id="aff7"><sup>7</sup><institution>Department of Cardiology, Shaare Zedek Medical Center</institution>, <addr-line>Jerusalem</addr-line>, <country>Israel</country></aff>
<aff id="aff8"><sup>8</sup><institution>Department of Cardiology, E. Wolfson Medical Center</institution>, <addr-line>Holon</addr-line>, <country>Israel</country></aff>
<aff id="aff9"><sup>9</sup><institution>Stroke Unit, Vall d'Hebron University Hospital</institution>, <addr-line>Barcelona</addr-line>, <country>Spain</country></aff>
<author-notes>
<fn fn-type="edited-by" id="fn0001">
<p>Edited by: Hang Yi, Wright State University, United States</p>
</fn>
<fn fn-type="edited-by" id="fn0002">
<p>Reviewed by: Tianqi Wang, University of Shanghai for Science and Technology, China</p>
<p>Jianan Zhao, United States Food and Drug Administration, United States</p>
</fn>
<corresp id="c001">&#x002A;Correspondence: Hilla Ben-Pazi, <email>benpazi@gmail.com</email></corresp>
</author-notes>
<pub-date pub-type="epub">
<day>16</day>
<month>06</month>
<year>2025</year>
</pub-date>
<pub-date pub-type="collection">
<year>2025</year>
</pub-date>
<volume>16</volume>
<elocation-id>1608651</elocation-id>
<history>
<date date-type="received">
<day>09</day>
<month>04</month>
<year>2025</year>
</date>
<date date-type="accepted">
<day>03</day>
<month>06</month>
<year>2025</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x00A9; 2025 Ben-Pazi, Jhashan, Salame, Cohen, Matot, Pazi, Kirma, Elmaliach, Lavi, Mintz, Corvaja, Dvir, Danenberg and Ribo.</copyright-statement>
<copyright-year>2025</copyright-year>
<copyright-holder>Ben-Pazi, Jhashan, Salame, Cohen, Matot, Pazi, Kirma, Elmaliach, Lavi, Mintz, Corvaja, Dvir, Danenberg and Ribo</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<p>From ancient Chinese medicine to medieval European practice, the carotid pulse has long been recognized as a vital window into vascular health. Yet in modern clinical medicine, this rich physiological signal has been largely overlooked. While artificial intelligence (AI) has transformed healthcare through advanced data interpretation, it has also inadvertently diverted focus from acquiring novel physiological data&#x2014;particularly from the carotid artery. This review highlights the underutilized potential of carotid hemodynamics and explores how emerging sensor technologies, combined with AI, can transform stroke prevention, real-time cerebrovascular monitoring, and broader vascular care. As a central conduit between the heart and brain, the carotid artery conveys dynamic hemodynamic information relevant not only to neurology, but also to cardiology and pulmonary medicine. Recent advances in non-invasive, continuous monitoring now enable real-time assessment of vascular stiffness, pulse wave patterns, and early cerebrovascular compromise&#x2014;capabilities that were previously inaccessible with traditional, intermittent evaluation methods. Focusing on the neurological context, this review outlines emerging opportunities in carotid monitoring, identifies key hemodynamic markers, and evaluates the clinical consequences of their underuse. By integrating AI with enhanced, continuous data acquisition from the carotid artery, the medical community may pursue new diagnostic and predictive pathways, advancing toward proactive, precision-based care and improved patient outcomes.</p>
</abstract>
<kwd-group>
<kwd>carotid artery</kwd>
<kwd>artificial intelligence</kwd>
<kwd>monitoring</kwd>
<kwd>stroke</kwd>
<kwd>pulse wave velocity</kwd>
<kwd>ultrasound</kwd>
<kwd>baro-sensors</kwd>
</kwd-group>
<counts>
<fig-count count="0"/>
<table-count count="2"/>
<equation-count count="0"/>
<ref-count count="28"/>
<page-count count="6"/>
<word-count count="4401"/>
</counts>
<custom-meta-wrap>
<custom-meta>
<meta-name>section-at-acceptance</meta-name>
<meta-value>Neurocritical and Neurohospitalist Care</meta-value>
</custom-meta>
</custom-meta-wrap>
</article-meta>
</front>
<body>
<sec sec-type="intro" id="sec1">
<label>1</label>
<title>Introduction</title>
<p>For centuries, the carotid pulse has served as a powerful diagnostic tool, valued across cultures&#x2014;from ancient Chinese medicine to medieval European practice&#x2014;for its ability to reflect internal health. Today, this long-standing physiological insight can be reimagined through modern technology: emerging tools now enable continuous, non-invasive monitoring of carotid signals. While clinical practice has historically prioritized established metrics like ECG, blood pressure, and oxygen saturation, there is now a clear opportunity to expand physiological monitoring by tapping into the underused potential of the carotid artery.</p>
<p>The stroke field, like many domains of medicine, is increasingly integrating artificial intelligence (AI) at multiple levels. Its most widespread application is in the interpretation of diagnostic imaging (<xref ref-type="bibr" rid="ref1">1</xref>). Furthermore, established stroke risk factors are now embedded within AI-driven models, improving predictive accuracy beyond what traditional approaches offer (<xref ref-type="bibr" rid="ref2">2</xref>). AI is also being applied to vascular imaging, particularly to enhance analysis of carotid artery narrowing and plaque morphology&#x2014;both widely used indicators of cerebrovascular risk (<xref ref-type="bibr" rid="ref3">3</xref>).</p>
<p>However, these imaging-based assessments are intermittent, offering only isolated snapshots of vascular health. This reliance on static evaluations reinforces the view of stroke as a sudden event, when it is a dynamic, escalating process&#x2014;more akin to a ticking time bomb that evolves silently before symptoms emerge. Single-point assessments lack the responsiveness needed for early intervention, and even the most advanced risk prediction models are of limited value without real-time alerts.</p>
<p>Shifting to continuous physiological monitoring enables early detection of hemodynamic changes, reframing stroke as a process that can be detected and potentially interrupted before irreversible damage occurs. A paradigm shift is underway&#x2014;from periodic risk estimation to a real-time diagnostic monitoring that can alert clinicians to pathological changes as they emerge and escalate (<xref ref-type="table" rid="tab1">Table 1</xref>). This mirrors advances in cardiology, where real-time alert systems are already used to detect deterioration and guide timely care (<xref ref-type="bibr" rid="ref4">4</xref>). A similar approach is now emerging in stroke prevention, enabled by wearable and implantable sensors paired with AI-driven signal analysis of the carotid arteries (<xref ref-type="bibr" rid="ref5">5</xref>, <xref ref-type="bibr" rid="ref6">6</xref>). This review explores the untapped value of carotid hemodynamics, introduces emerging monitoring approaches, and discusses their potential to transform stroke prevention and vascular health.</p>
<table-wrap position="float" id="tab1">
<label>Table 1</label>
<caption>
<p>Moving from predictive to diagnostic markers.</p>
</caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th align="left" valign="top">Category</th>
<th align="left" valign="top">Examples</th>
<th align="left" valign="top">Clinical utility</th>
</tr>
</thead>
<tbody>
<tr>
<td align="left" valign="middle">Predictive</td>
<td align="left" valign="middle">Arterial stiffness, vascular reactivity</td>
<td align="left" valign="middle">Useful for risk stratification</td>
</tr>
<tr>
<td align="left" valign="middle">Diagnostic</td>
<td align="left" valign="middle">Plaque morphology, stenosis severity,</td>
<td align="left" valign="middle">Detect pre-existing abnormalities</td>
</tr>
<tr>
<td align="left" valign="middle">Real-time Monitoring</td>
<td align="left" valign="middle">Continuous detection of hemodynamic changes</td>
<td align="left" valign="middle">Enables early alerts for stroke prevention</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
<sec id="sec2">
<label>2</label>
<title>Aren&#x2019;t there any available monitoring tools for real time stroke detection?</title>
<p>While cardiac parameters are continuously monitored in clinical settings, real-time stroke monitoring remains notably limited. Despite advancements in noninvasive stroke diagnostic modalities, existing technologies have yet to consistently demonstrate early stroke detection or significant improvement in patient outcomes.</p>
<sec id="sec3">
<label>2.1</label>
<title>Traditional cardiovascular tools</title>
<p>Such as blood pressure monitoring, ECG, and echocardiography, provide limited real-time insights into cerebrovascular dynamics. Large-scale, AI-driven initiatives aiming to predict stroke via wearable devices, including studies by Apple and Johns Hopkins University, have not yet demonstrated clinical efficacy. To date, no results have been published from the ongoing NIH-funded trial evaluating Apple Watch-guided anticoagulation management for stroke prevention. While shifting from risk estimation toward real-time stroke detection holds theoretical promise for early intervention, clinical validation remains lacking (<xref ref-type="bibr" rid="ref7">7</xref>). However, recent advances in AI and deep learning offer promising avenues for real-time stroke detection. For example, recent work has introduced real-time stroke detection via real-time facial paralysis detection with enhanced accuracy and privacy on edge devices (<xref ref-type="bibr" rid="ref8">8</xref>). Other research has demonstrated deep learning-based prediction systems using real-time EEG signals, achieving high accuracy with low false positive rates (<xref ref-type="bibr" rid="ref9">9</xref>). These emerging efforts demonstrates a growing momentum in leveraging AI for continuous stroke monitoring, complementing physiological sensors and promising to bridge existing gaps in real-time detection.</p>
</sec>
<sec id="sec4">
<label>2.2</label>
<title>The bispectral index</title>
<p>The bispectral index (BIS) derived from EEG signals, is widely used intraoperatively to detect cerebral ischemia, but its sensitivity is limited, particularly for subcortical events. Originally developed to assess anesthesia depth, BIS shows some correlation with ischemia during carotid clamping but lacks a clinically reliable threshold for stroke detection. Consequently, BIS frequently yields false positives, limiting its standalone effectiveness (<xref ref-type="bibr" rid="ref10">10</xref>).</p>
</sec>
<sec id="sec5">
<label>2.3</label>
<title>Near-infrared spectroscopy</title>
<p>Provides noninvasive monitoring of cerebral oxygenation with a high negative predictive value for hypoperfusion. However, its utility is restricted by sensor placement primarily over the frontal lobes, inter-device variability, and susceptibility to extracerebral interference. Despite promising sensitivity and specificity, the absence of a universally accepted threshold limits its clinical reliability (<xref ref-type="bibr" rid="ref11">11</xref>). A recent systematic review reported no significant advantage of near-infrared spectroscopy (NIRS) over standard monitoring regarding mortality, neuroprotection, or adverse events (<xref ref-type="bibr" rid="ref12">12</xref>).</p>
</sec>
<sec id="sec6">
<label>2.4</label>
<title>Transcranial Doppler ultrasound</title>
<p>Effectively detects cerebral microemboli and assesses blood flow dynamics (<xref ref-type="bibr" rid="ref13">13</xref>). Yet, its use in continuous bedside monitoring is hindered by operator dependency, anatomical variability among patients, and the requirement for manual probe stabilization. Additionally, continuous robotic transcranial Doppler (TCD) remains limited by high costs, patient positioning challenges, the need for specialized training, and insufficient large-scale clinical validation specific to stroke detection (<xref ref-type="bibr" rid="ref14">14</xref>).</p>
</sec>
<sec id="sec7">
<label>2.5</label>
<title>Multimodal monitoring</title>
<p>Strategies combining different technologies might provide enhanced diagnostic accuracy and clinical utility. For instance, integrating EEG and TCD biomarkers significantly improved the prediction of delayed cerebral ischemia (DCI) in subarachnoid hemorrhage (SAH) patients (<xref ref-type="bibr" rid="ref15">15</xref>). Further development and validation of such multimodal approaches may overcome the limitations of current single-modality tools and strengthen clinical decision-making.</p>
</sec>
</sec>
<sec id="sec8">
<label>3</label>
<title>Why use the carotid for brain monitoring?</title>
<p>Most research on carotid artery disease and stroke has focused on anatomical markers&#x2014;such as luminal narrowing and plaque morphology&#x2014;as the basis for clinical decision-making, especially for interventions like carotid endarterectomy and stenting (<xref ref-type="bibr" rid="ref16">16</xref>). These structural features are readily assessed through imaging. However, there is increasing recognition that anatomical data alone may not fully capture stroke risk. Real-time hemodynamic indicators, although more difficult to acquire, could provide functionally richer insights.</p>
<p>The carotid artery plays a central role in maintaining cerebrovascular health. It contains baroreceptors in the carotid sinus that continuously regulate blood pressure, heart rate, and vascular tone, dynamically modulating cerebral perfusion in response to physiological (<xref ref-type="bibr" rid="ref17">17</xref>). These mechanosensitive receptors are located at the carotid bifurcation&#x2014;a region prone to turbulent flow, plaque buildup, and oscillatory shear stress&#x2014;which may explain their strategic placement (<xref ref-type="bibr" rid="ref18">18</xref>, <xref ref-type="bibr" rid="ref19">19</xref>).</p>
<p>A key but underutilized functional marker is cerebrovascular reactivity (CVR), particularly CO&#x2082; reactivity (CO&#x2082;R). This is typically measured via changes in cerebral blood flow velocity during controlled hypercapnia (e.g., breath-holding or CO&#x2082; inhalation). A meta-analysis by Reinhard et al. (<xref ref-type="bibr" rid="ref20">20</xref>), involving 754 patients with carotid stenosis or occlusion, found that impaired CO&#x2082;R (pCi&#x202F;&#x003C;&#x202F;20%) was strongly associated with increased ipsilateral stroke risk. Each 10% decrease in CO&#x2082;R corresponded to a 1.64-fold increase in hazard. Importantly, this relationship held true even in asymptomatic individuals, supporting its predictive value beyond symptoms.</p>
<p>Although functional tests like CO&#x2082;R offer valuable insights, they are rarely used and typically limited to single-point measurements&#x2014;failing to reflect the dynamic, evolving nature of stroke. Despite its potential, the functional role of the carotid artery remains underutilized. Moving from static imaging to continuous, real-time monitoring could transform the carotid into an active sentinel, enabling earlier detection and intervention before neurological damage occurs.</p>
</sec>
<sec id="sec9">
<label>4</label>
<title>What are the existing sensors to use for hemodynamic carotid monitoring?</title>
<p>Emerging technologies are transforming carotid hemodynamic monitoring by moving beyond static imaging toward real-time, continuous assessment using a range of sensor modalities. Flow sensors such as Doppler ultrasound and magnetic flow meters measure carotid blood velocity, while pressure sensors&#x2014;including piezoelectric and capacitive types&#x2014;detect arterial wall displacement. Motion-based sensors, such as accelerometers and strain gauges, capture tissue vibration and deformation. Each sensor type targets a distinct physiological parameter, offering a more comprehensive understanding of cerebrovascular status (<xref ref-type="table" rid="tab2">Table 2</xref>).</p>
<table-wrap position="float" id="tab2">
<label>Table 2</label>
<caption>
<p>Sensor modalities for carotid monitoring.</p>
</caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th align="left" valign="top">Modality</th>
<th align="left" valign="top">Measurement type</th>
<th align="left" valign="top">Active/passive</th>
<th align="left" valign="top">Cost</th>
<th align="left" valign="top">Advantages</th>
<th align="left" valign="top">Challenges</th>
</tr>
</thead>
<tbody>
<tr>
<td align="left" valign="top">PPG</td>
<td align="left" valign="top">Flow</td>
<td align="left" valign="top">Active</td>
<td align="left" valign="top">$</td>
<td align="left" valign="top">Simple</td>
<td align="left" valign="top">Accuracy affected by skin color</td>
</tr>
<tr>
<td align="left" valign="top">Ultrasound (US)</td>
<td align="left" valign="top">Flow</td>
<td align="left" valign="top">Active</td>
<td align="left" valign="top">$$</td>
<td align="left" valign="top">Provides extensive detailed data</td>
<td align="left" valign="top">Requires precise sensor positioning</td>
</tr>
<tr>
<td align="left" valign="middle">Magnetic Sensor (Hall Effect)</td>
<td align="left" valign="middle">Flow</td>
<td align="left" valign="middle">Passive</td>
<td align="left" valign="middle">$$</td>
<td align="left" valign="middle">Contactless, measurement, durable</td>
<td align="left" valign="middle">Sensitive to external magnetic fields</td>
</tr>
<tr>
<td align="left" valign="middle">Accelerometer</td>
<td align="left" valign="middle">Motion/vibration</td>
<td align="left" valign="middle">Passive</td>
<td align="left" valign="middle">$</td>
<td align="left" valign="middle">Highly sensitivity</td>
<td align="left" valign="middle">Susceptible to motion artifacts</td>
</tr>
<tr>
<td align="left" valign="middle">Strain gauge sensor (PESG)</td>
<td align="left" valign="middle">Pressure/displacement</td>
<td align="left" valign="middle">Passive</td>
<td align="left" valign="middle">$$</td>
<td align="left" valign="middle">Measures direct contact force</td>
<td align="left" valign="middle">Requires frequent calibration</td>
</tr>
<tr>
<td align="left" valign="middle">Piezoelectric</td>
<td align="left" valign="middle">Pressure/displacement</td>
<td align="left" valign="middle">Active</td>
<td align="left" valign="middle">$</td>
<td align="left" valign="middle">High sensitivity, accurate waveform</td>
<td align="left" valign="middle">Expensive, sensitive to motion</td>
</tr>
<tr>
<td align="left" valign="middle">Optical reflection sensor</td>
<td align="left" valign="middle">Pressure/displacement</td>
<td align="left" valign="middle">Active</td>
<td align="left" valign="middle">$$</td>
<td align="left" valign="middle">Non-contact measurement capability</td>
<td align="left" valign="middle">Affected by ambient light conditions</td>
</tr>
<tr>
<td align="left" valign="middle">Capacitive sensor</td>
<td align="left" valign="middle">Pressure/displacement</td>
<td align="left" valign="middle">Passive</td>
<td align="left" valign="middle">$$</td>
<td align="left" valign="middle">High sensitivity, stable signal</td>
<td align="left" valign="middle">Requires controlled contact pressure</td>
</tr>
</tbody>
</table>
</table-wrap>
<sec id="sec10">
<label>4.1</label>
<title>Flow-based sensors</title>
<p>Include ultrasound-based technologies like Doppler systems and flexible skin-adhering patches, which allow for non-invasive, real-time measurements of blood flow velocity and waveform morphology (<xref ref-type="bibr" rid="ref5">5</xref>). A recent innovation includes the point-of-care ultrasound (POCUS) approach, which has shown promise as a rapid bedside solution. In the POCUS-LVO study, trained non-specialists successfully performed carotid ultrasound exams in under 3 min, supporting its feasibility for fast stroke triage in emergency settings (<xref ref-type="bibr" rid="ref21">21</xref>). In addition, magnetic Hall-effect-based sensors have been explored for local Pulse wave velocity (PWV) measurement. A dual magnetic plethysmograph (MPG) probe, equipped with Hall-effect sensors and permanent magnets, was validated <italic>in vivo</italic> for measuring carotid artery PWV (<xref ref-type="bibr" rid="ref22">22</xref>).</p>
</sec>
<sec id="sec11">
<label>4.2</label>
<title>Pressure-based sensors</title>
<p>Have also shown promising results. A comparative study by Wang et al. evaluated four sensor types&#x2014;piezoresistive strain gauge (PESG), piezoelectric tonometer, accelerometer, and optical reflection sensors&#x2014;across multiple arterial sites, including the carotid. They found that medium contact pressure produced the most stable signals, and that tonometer and accelerometer sensors demonstrated the highest stability and reproducibility (ICC&#x202F;&#x003E;&#x202F;0.80). In contrast, optical sensors were vulnerable to ambient light interference, while PESG sensors were sensitive to variations in contact pressure.</p>
</sec>
</sec>
<sec id="sec12">
<label>5</label>
<title>What hemodynamic factors can we use?</title>
<p>Various hemodynamic parameters can be utilized for stroke risk assessment and early detection, particularly through non-invasive waveform analysis.</p>
<sec id="sec13">
<label>5.1</label>
<title>Waveform analysis</title>
<p>Provides several valuable metrics. Carotid flow volume has been shown to inversely correlate with atherosclerosis severity (r&#x202F;=&#x202F;&#x2212;0.696) (<xref ref-type="bibr" rid="ref23">23</xref>). Additionally, differences in end-diastolic velocity between carotid arteries measured using point-of-care ultrasound (POCUS) accurately predict large vessel occlusion (LVO), achieving high diagnostic accuracy (AUC&#x202F;=&#x202F;0.90; specificity&#x202F;=&#x202F;83%). Combining waveform parameters further enhances diagnostic capabilities. Shimada et al. (<xref ref-type="bibr" rid="ref24">24</xref>) utilized differences in amplitude, timing, and shape of carotid pulse waves, applying logistic regression to detect carotid artery occlusion, achieving a diagnostic accuracy of 0.65.</p>
</sec>
<sec id="sec14">
<label>5.2</label>
<title>Pulse wave velocity</title>
<p>The speed at which arterial pressure waves propagate&#x2014;is among the most validated hemodynamic indicators. Pulse wave velocity (PWV) is an established surrogate measure of arterial stiffness, with higher values indicating reduced arterial compliance. It can be assessed regionally (e.g., carotid-femoral) or locally at the carotid artery, where local PWV provides targeted insight into arterial elasticity (<xref ref-type="bibr" rid="ref23">23</xref>). Although PWV is not validated as a standalone diagnostic tool for stroke, it remains a strong predictive marker. Elevated PWV and carotid stiffness have consistently been associated with increased stroke risk, poor prognosis, and cognitive decline (<xref ref-type="bibr" rid="ref24">24</xref>, <xref ref-type="bibr" rid="ref25">25</xref>). Notably, PWV asymmetry between the left and right carotid arteries during acute stroke episodes has uncovered diagnostic differences that were not detected by standard flow velocity alone (<xref ref-type="bibr" rid="ref26">26</xref>).</p>
<p>Collectively, waveform shape, bilateral asymmetry, flow volume, carotid stiffness, and PWV form a robust set of hemodynamic biomarkers, providing essential tools for non-invasive cerebrovascular assessment and enabling AI-driven stroke prediction and prevention strategies (<xref ref-type="bibr" rid="ref27">27</xref>, <xref ref-type="bibr" rid="ref28">28</xref>).</p>
</sec>
</sec>
<sec id="sec15">
<label>6</label>
<title>What are the main challenges?</title>
<p>The integration of artificial intelligence (AI) and advanced sensor technologies for continuous carotid monitoring offers substantial promise for proactive stroke prevention, but several significant challenges must be overcome to realize this potential fully.</p>
<sec id="sec16">
<label>6.1</label>
<title>Technical developmental challenges</title>
<p>Developing reliable and precise carotid monitoring systems requires overcoming considerable technical complexities. High-resolution sensors capable of continuous, accurate measurements of carotid hemodynamics are challenging to design and produce, demanding substantial engineering resources and iterative research and development (R&#x0026;D) processes. Transitioning these technologies from laboratory prototypes to clinically usable devices involve extensive testing, validation, and refinement, often placing significant financial and logistical burdens on research institutions and commercial enterprises.</p>
<p>Furthermore, maintaining device performance and ensuring user comfort during prolonged monitoring periods adds complexity. Wearable sensors must balance accuracy, usability, durability, and patient compliance, necessitating multidisciplinary collaboration across engineering, medical, and design teams.</p>
</sec>
<sec id="sec17">
<label>6.2</label>
<title>Data acquisition</title>
<p>While retrospective datasets currently dominate AI applications in healthcare&#x2014;particularly diagnostic imaging&#x2014;they inherently lack the dynamic, real-time physiological data critical for conditions like acute stroke. Capturing these real-time carotid waveforms and integrating them into predictive models poses substantial hurdles. Continuous data acquisition demands dedicated equipment and ongoing infrastructure investments. Additionally, existing databases, often commercially valuable and readily accessible, reduce incentives to generate new physiological datasets, resulting in fewer resources allocated toward novel data collection.</p>
<p>Moreover, even when collected, new physiological signals frequently remain disconnected from existing electronic medical records (EMRs), limiting their availability for clinical decision-making and large-scale analytics. Overcoming this barrier requires deliberate and coordinated efforts to integrate new physiological data streams into healthcare systems and clinical workflows.</p>
</sec>
<sec id="sec18">
<label>6.3</label>
<title>Regulatory and ethical challenges</title>
<p>Current regulatory frameworks often lag rapid advancements in AI and sensor-based technologies. Novel diagnostic tools utilizing AI-driven continuous monitoring systems must navigate complex and often outdated regulatory pathways. These frameworks were not initially designed to handle the pace of innovation inherent to AI technologies, causing significant delays, uncertainty, and increased costs during the approval process.</p>
<p>Ethical considerations also pose significant challenges. Issues regarding patient privacy, data security, informed consent, and the ethical use of AI-generated insights must be thoroughly addressed. Transparent and robust ethical frameworks are needed to manage patient data responsibly, ensuring trust and acceptance among healthcare professionals and patients.</p>
</sec>
<sec id="sec19">
<label>6.4</label>
<title>Clinical integration and adoption challenges</title>
<p>Integrating continuous carotid monitoring systems into clinical practice presents numerous practical hurdles. Healthcare providers must adopt established workflows to incorporate new technologies, which can disrupt routines and create resistance among medical staff. Additionally, uncertainties regarding the clinical utility, reliability, and overall value of these novel systems may slow adoption.</p>
<p>To effectively promote clinical adoption, extensive validation studies involving diverse patient populations are necessary. These studies must clearly demonstrate not only the clinical efficacy and safety of continuous carotid monitoring but also its cost-effectiveness and practicality in real-world healthcare settings. Ongoing education and training for healthcare providers will be crucial in facilitating smooth transitions and ensuring optimal use of these technologies.</p>
</sec>
<sec id="sec20">
<label>6.5</label>
<title>Economic challenges</title>
<p>Developing, validating, and implementing novel sensor-based AI technologies entail substantial financial investments. High upfront costs associated with research, device manufacturing, and regulation can deter funding and slow innovation, especially when compared to more immediate returns from existing data-driven solutions. Additionally, reimbursement strategies for diagnostic innovations often lag, further complicating the economic viability of these novel tools.</p>
<p>Securing sustainable financial support from both private and public sectors, along with favorable reimbursement policies, is essential to enable continued development, validation, and widespread adoption of continuous carotid monitoring technologies.</p>
</sec>
</sec>
<sec sec-type="conclusions" id="sec21">
<label>7</label>
<title>Conclusion</title>
<p>Advancements in AI and sensor technologies present unprecedented opportunities for transforming stroke prevention strategies from reactive management to proactive, real-time intervention. Historically valued for its enhanced risk stratification, and precision-based preventive care the carotid pulse now offers even greater potential through modern technological innovations. Continuous carotid monitoring holds considerable promise in providing critical physiological insights, enabling earlier stroke detection. Moving toward systematic expansion of real-time physiological monitoring can significantly improve stroke outcomes. However, achieving this requires addressing and overcoming the significant technical, regulatory, ethical, clinical, and economic challenges outlined above. Comprehensive collaboration among researchers, healthcare providers, regulatory agencies, and policy-makers is essential to overcome these barriers and unlock the full potential of continuous carotid monitoring, ultimately improving patient outcomes and substantially reducing stroke-related morbidity and mortality.</p>
</sec>
</body>
<back>
<sec sec-type="author-contributions" id="sec22">
<title>Author contributions</title>
<p>HB-P: Writing &#x2013; original draft. SJ: Writing &#x2013; review &#x0026; editing. HS: Writing &#x2013; review &#x0026; editing. HC: Writing &#x2013; review &#x0026; editing, Software, Formal analysis. IM: Writing &#x2013; review &#x0026; editing. MP: Writing &#x2013; review &#x0026; editing. YK: Writing &#x2013; review &#x0026; editing. LE: Writing &#x2013; review &#x0026; editing. YL: Writing &#x2013; review &#x0026; editing. PM: Writing &#x2013; review &#x0026; editing. NC: Writing &#x2013; review &#x0026; editing. DD: Writing &#x2013; review &#x0026; editing. HD: Writing &#x2013; review &#x0026; editing. MR: Writing &#x2013; review &#x0026; editing.</p>
</sec>
<sec sec-type="funding-information" id="sec23">
<title>Funding</title>
<p>The author(s) declare that financial support was received for the research and/or publication of this article. This work was supported by state funding from the Israeli Innovation Authority and the European Innovation Council, both of which provided financial support for research and development activities. These funders had no role in the design, data collection, analysis, or interpretation of the study.</p>
</sec>
<sec sec-type="COI-statement" id="sec24">
<title>Conflict of interest</title>
<p>HB-P is the founder and CEO of Avertto Medical LTD, a company developing a carotid monitoring system. MC, YK, LE, YL and PM are employees of Avertto Medical LTD. SJ, HC, and MR serve as principal investigators for Avertto Medical LTD. HS is a sub-investigator for Avertto Medical LTD. IM and NC are scientific advisors to Avertto Medical LTD.</p>
<p>The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
<p>The author(s) declared that they were an editorial board member of Frontiers, at the time of submission. This had no impact on the peer review process and the final decision.</p>
</sec>
<sec sec-type="ai-statement" id="sec25">
<title>Generative AI statement</title>
<p>The authors declare that Gen AI was used in the creation of this manuscript. The author(s) verified and took full responsibility for using generative AI to prepare this manuscript. Generative AI tools, specifically OpenAI&#x2019;s ChatGPT, were used to assist in the refinement of language, grammar, and structure, as well as to draft portions of the abstract, scope justification, and conflict of interest statements. All content generated was critically reviewed, edited, and approved by the authors to ensure accuracy, originality, and alignment with the scientific intent of the manuscript. No unpublished data or confidential information was input into the AI platform.</p>
</sec>
<sec sec-type="disclaimer" id="sec26">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ref-list>
<title>References</title>
<ref id="ref1"><label>1.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Murray</surname> <given-names>NM</given-names></name> <name><surname>Unberath</surname> <given-names>M</given-names></name> <name><surname>Hager</surname> <given-names>GD</given-names></name> <name><surname>Hui</surname> <given-names>FK</given-names></name></person-group>. <article-title>Artificial intelligence to diagnose ischemic stroke and identify large vessel occlusions: a systematic review</article-title>. <source>J Neurointerv Surg</source>. (<year>2020</year>) <volume>12</volume>:<fpage>156</fpage>&#x2013;<lpage>64</lpage>. doi: <pub-id pub-id-type="doi">10.1136/neurintsurg-2019-015135</pub-id>, PMID: <pub-id pub-id-type="pmid">31594798</pub-id></citation></ref>
<ref id="ref2"><label>2.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Colangelo</surname> <given-names>G</given-names></name> <name><surname>Ribo</surname> <given-names>M</given-names></name> <name><surname>Montiel</surname> <given-names>E</given-names></name> <name><surname>Dominguez</surname> <given-names>D</given-names></name> <name><surname>Oliv&#x00E9;-Gadea</surname> <given-names>M</given-names></name> <name><surname>Muchada</surname> <given-names>M</given-names></name> <etal/></person-group>. <article-title>Prerisk: a personalized, artificial intelligence-based and statistically-based stroke recurrence predictor for recurrent stroke</article-title>. <source>Stroke</source>. (<year>2024</year>) <volume>55</volume>:<fpage>1200</fpage>&#x2013;<lpage>9</lpage>. doi: <pub-id pub-id-type="doi">10.1161/STROKEAHA.123.043691</pub-id>, PMID: <pub-id pub-id-type="pmid">38545798</pub-id></citation></ref>
<ref id="ref3"><label>3.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gupta</surname> <given-names>A</given-names></name> <name><surname>Baradaran</surname> <given-names>H</given-names></name> <name><surname>Schweitzer</surname> <given-names>AD</given-names></name> <name><surname>Kamel</surname> <given-names>H</given-names></name> <name><surname>Pandya</surname> <given-names>A</given-names></name> <name><surname>Delgado</surname> <given-names>D</given-names></name> <etal/></person-group>. <article-title>Carotid plaque MRI and stroke risk: a systematic review and meta-analysis</article-title>. <source>Stroke</source>. (<year>2013</year>) <volume>44</volume>:<fpage>3071</fpage>&#x2013;<lpage>7</lpage>. doi: <pub-id pub-id-type="doi">10.1161/STROKEAHA.113.002551</pub-id>, PMID: <pub-id pub-id-type="pmid">23988640</pub-id></citation></ref>
<ref id="ref4"><label>4.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Shah</surname> <given-names>K</given-names></name> <name><surname>Wang</surname> <given-names>A</given-names></name> <name><surname>Chen</surname> <given-names>Y</given-names></name> <name><surname>Munjal</surname> <given-names>J</given-names></name> <name><surname>Chhabra</surname> <given-names>S</given-names></name> <name><surname>Stange</surname> <given-names>A</given-names></name> <etal/></person-group>. <article-title>Automated loss of pulse detection on a consumer smartwatch</article-title>. <source>Nature</source>. (<year>2025</year>) <volume>642</volume>:<fpage>174</fpage>&#x2013;<lpage>81</lpage>. doi: <pub-id pub-id-type="doi">10.1038/s41586-025-08810-9</pub-id>, PMID: <pub-id pub-id-type="pmid">40010378</pub-id></citation></ref>
<ref id="ref5"><label>5.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kenny</surname> <given-names>J-&#x00C9;S</given-names></name> <name><surname>Munding</surname> <given-names>CE</given-names></name> <name><surname>Eibl</surname> <given-names>JK</given-names></name> <name><surname>Eibl</surname> <given-names>AM</given-names></name> <name><surname>Long</surname> <given-names>BF</given-names></name> <name><surname>Boyes</surname> <given-names>A</given-names></name> <etal/></person-group>. <article-title>A novel, hands-free ultrasound patch for continuous monitoring of quantitative Doppler in the carotid artery</article-title>. <source>Sci Rep</source>. (<year>2021</year>) <volume>11</volume>:<fpage>7780</fpage>. doi: <pub-id pub-id-type="doi">10.1038/s41598-021-87116-y</pub-id>, PMID: <pub-id pub-id-type="pmid">33833288</pub-id></citation></ref>
<ref id="ref6"><label>6.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Herbert</surname> <given-names>R</given-names></name> <name><surname>Lim</surname> <given-names>H-R</given-names></name> <name><surname>Rigo</surname> <given-names>B</given-names></name> <name><surname>Yeo</surname> <given-names>W-H</given-names></name></person-group>. <article-title>Fully implantable wireless batteryless vascular electronics with printed soft sensors for multiplex sensing of hemodynamics</article-title>. <source>Sci Adv</source>. (<year>2022</year>) <volume>8</volume>:<fpage>eabm1175</fpage>. doi: <pub-id pub-id-type="doi">10.1126/sciadv.abm1175</pub-id>, PMID: <pub-id pub-id-type="pmid">35544557</pub-id></citation></ref>
<ref id="ref7"><label>7.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Eisenkraft</surname> <given-names>A</given-names></name> <name><surname>Goldstein</surname> <given-names>N</given-names></name> <name><surname>Merin</surname> <given-names>R</given-names></name> <name><surname>Fons</surname> <given-names>M</given-names></name> <name><surname>Ishay</surname> <given-names>AB</given-names></name> <name><surname>Nachman</surname> <given-names>D</given-names></name> <etal/></person-group>. <article-title>Developing a real-time detection tool and an early warning score using a continuous wearable multi-parameter monitor</article-title>. <source>Front Physiol</source>. (<year>2023</year>) <volume>14</volume>:<fpage>1138647</fpage>. doi: <pub-id pub-id-type="doi">10.3389/fphys.2023.1138647</pub-id>, PMID: <pub-id pub-id-type="pmid">37064911</pub-id></citation></ref>
<ref id="ref8"><label>8.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Elhanashi</surname> <given-names>A</given-names></name> <name><surname>Dini</surname> <given-names>P</given-names></name> <name><surname>Saponara</surname> <given-names>S</given-names></name> <name><surname>Zheng</surname> <given-names>Q</given-names></name></person-group>. <article-title>Telestroke: real-time stroke detection with federated learning and YOLOv8 on edge devices</article-title>. <source>J Real-Time Image Proc</source>. (<year>2024</year>) <volume>21</volume>:<fpage>121</fpage>. doi: <pub-id pub-id-type="doi">10.1007/s11554-024-01500-1</pub-id></citation></ref>
<ref id="ref9"><label>9.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Choi</surname> <given-names>Y-A</given-names></name> <name><surname>Park</surname> <given-names>S-J</given-names></name> <name><surname>Jun</surname> <given-names>J-A</given-names></name> <name><surname>Pyo</surname> <given-names>C-S</given-names></name> <name><surname>Cho</surname> <given-names>K-H</given-names></name> <name><surname>Lee</surname> <given-names>H-S</given-names></name> <etal/></person-group>. <article-title>Deep learning-based stroke disease prediction system using real-time bio signals</article-title>. <source>Sensors</source>. (<year>2021</year>) <volume>21</volume>:<fpage>269</fpage>. doi: <pub-id pub-id-type="doi">10.3390/s21134269</pub-id>, PMID: <pub-id pub-id-type="pmid">34206540</pub-id></citation></ref>
<ref id="ref10"><label>10.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Estruch-P&#x00E9;rez</surname> <given-names>MJ</given-names></name> <name><surname>Ausina-Aguilar</surname> <given-names>A</given-names></name> <name><surname>Barber&#x00E1;-Alacreu</surname> <given-names>M</given-names></name> <name><surname>S&#x00E1;nchez-Morillo</surname> <given-names>J</given-names></name> <name><surname>Solaz-Rold&#x00E1;n</surname> <given-names>C</given-names></name> <name><surname>Morales-Su&#x00E1;rez-Varela</surname> <given-names>MM</given-names></name></person-group>. <article-title>Bispectral index changes in carotid surgery</article-title>. <source>Ann Vasc Surg</source>. (<year>2010</year>) <volume>24</volume>:<fpage>393</fpage>&#x2013;<lpage>9</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.avsg.2009.08.005</pub-id>, PMID: <pub-id pub-id-type="pmid">19932952</pub-id></citation></ref>
<ref id="ref11"><label>11.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Stilo</surname> <given-names>F</given-names></name> <name><surname>Montelione</surname> <given-names>N</given-names></name> <name><surname>Paolini</surname> <given-names>J</given-names></name> <name><surname>Strumia</surname> <given-names>A</given-names></name> <name><surname>Cuccarelli</surname> <given-names>M</given-names></name> <name><surname>Nenna</surname> <given-names>A</given-names></name> <etal/></person-group>. <article-title>Current status of brain monitoring during carotid endarterectomy</article-title>. <source>JVS-Vascular Insights</source>. (<year>2024</year>) <volume>2</volume>:<fpage>60</fpage>. doi: <pub-id pub-id-type="doi">10.1016/j.jvsvi.2024.100060</pub-id></citation></ref>
<ref id="ref12"><label>12.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hansen</surname> <given-names>ML</given-names></name> <name><surname>Hyttel-S&#x00F8;rensen</surname> <given-names>S</given-names></name> <name><surname>Jakobsen</surname> <given-names>JC</given-names></name> <name><surname>Gluud</surname> <given-names>C</given-names></name> <name><surname>Kooi</surname> <given-names>EMW</given-names></name> <name><surname>Mintzer</surname> <given-names>J</given-names></name> <etal/></person-group>. <article-title>Cerebral near-infrared spectroscopy monitoring (NIRS) in children and adults: a systematic review with meta-analysis</article-title>. <source>Pediatr Res</source>. (<year>2024</year>) <volume>96</volume>:<fpage>856</fpage>&#x2013;<lpage>67</lpage>. doi: <pub-id pub-id-type="doi">10.1038/s41390-022-01995-z</pub-id>, PMID: <pub-id pub-id-type="pmid">35194162</pub-id></citation></ref>
<ref id="ref13"><label>13.</label> <citation citation-type="book"><person-group person-group-type="author"><name><surname>Kim</surname> <given-names>Y</given-names></name> <name><surname>Lee</surname> <given-names>S</given-names></name> <name><surname>Root</surname> <given-names>D</given-names></name> <name><surname>Manchester</surname> <given-names>S</given-names></name> <name><surname>Dua</surname> <given-names>A</given-names></name></person-group>. <article-title>Transcranial Doppler (non-imaging)</article-title> In: <person-group person-group-type="editor"><name><surname>Dua</surname> <given-names>A</given-names></name> <name><surname>Root</surname> <given-names>D</given-names></name> <name><surname>Manchester</surname> <given-names>S</given-names></name> <name><surname>Kim</surname> <given-names>Y</given-names></name></person-group>, editors. <source>The Massachusetts General Hospital clinical approach to vascular ultrasound: Protocols and procedures</source>. <publisher-loc>Cham</publisher-loc>: <publisher-name>Springer International Publishing</publisher-name> (<year>2022</year>). <fpage>15</fpage>&#x2013;<lpage>22</lpage>.</citation></ref>
<ref id="ref14"><label>14.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zeiler</surname> <given-names>FA</given-names></name> <name><surname>Smielewski</surname> <given-names>P</given-names></name></person-group>. <article-title>Application of robotic transcranial Doppler for extended duration recording in moderate/severe traumatic brain injury: first experiences</article-title>. <source>Crit Ultrasound J</source>. (<year>2018</year>) <volume>10</volume>:<fpage>16</fpage>. doi: <pub-id pub-id-type="doi">10.1186/s13089-018-0097-0</pub-id>, PMID: <pub-id pub-id-type="pmid">30033501</pub-id></citation></ref>
<ref id="ref15"><label>15.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chen</surname> <given-names>HY</given-names></name> <name><surname>Elmer</surname> <given-names>J</given-names></name> <name><surname>Zafar</surname> <given-names>SF</given-names></name> <name><surname>Ghanta</surname> <given-names>M</given-names></name> <name><surname>Moura Junior</surname> <given-names>V</given-names></name> <name><surname>Rosenthal</surname> <given-names>ES</given-names></name> <etal/></person-group>. <article-title>Combining transcranial Doppler and EEG data to predict delayed cerebral ischemia after subarachnoid hemorrhage</article-title>. <source>Neurology</source>. (<year>2022</year>) <volume>98</volume>:<fpage>e459</fpage>&#x2013;<lpage>69</lpage>. doi: <pub-id pub-id-type="doi">10.1212/WNL.0000000000013126</pub-id>, PMID: <pub-id pub-id-type="pmid">34845057</pub-id></citation></ref>
<ref id="ref16"><label>16.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kallmayer</surname> <given-names>M</given-names></name> <name><surname>Tsantilas</surname> <given-names>P</given-names></name> <name><surname>Zieger</surname> <given-names>C</given-names></name> <name><surname>Ahmed</surname> <given-names>A</given-names></name> <name><surname>S&#x00F6;llner</surname> <given-names>H</given-names></name> <name><surname>Zimmermann</surname> <given-names>A</given-names></name> <etal/></person-group>. <article-title>Ultrasound surveillance after CAS and CEA: what&#x2019;s the evidence?</article-title> <source>J Cardiovasc Surg</source>. (<year>2014</year>) <volume>55</volume>:<fpage>33</fpage>&#x2013;<lpage>41</lpage>.</citation></ref>
<ref id="ref17"><label>17.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chapleau</surname> <given-names>MW</given-names></name> <name><surname>Li</surname> <given-names>Z</given-names></name> <name><surname>Meyrelles</surname> <given-names>SS</given-names></name> <name><surname>Ma</surname> <given-names>X</given-names></name> <name><surname>Abboud</surname> <given-names>FM</given-names></name></person-group>. <article-title>Mechanisms determining sensitivity of baroreceptor afferents in health and disease</article-title>. <source>Ann N Y Acad Sci</source>. (<year>2001</year>) <volume>940</volume>:<fpage>1</fpage>&#x2013;<lpage>19</lpage>. doi: <pub-id pub-id-type="doi">10.1111/j.1749-6632.2001.tb03662.x</pub-id>, PMID: <pub-id pub-id-type="pmid">11458669</pub-id></citation></ref>
<ref id="ref18"><label>18.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Porzionato</surname> <given-names>A</given-names></name> <name><surname>Macchi</surname> <given-names>V</given-names></name> <name><surname>Stecco</surname> <given-names>C</given-names></name> <name><surname>De Caro</surname> <given-names>R</given-names></name></person-group>. <article-title>The carotid sinus nerve-structure, function, and clinical implications</article-title>. <source>Anat Rec</source>. (<year>2019</year>) <volume>302</volume>:<fpage>575</fpage>&#x2013;<lpage>87</lpage>. doi: <pub-id pub-id-type="doi">10.1002/ar.23829</pub-id></citation></ref>
<ref id="ref19"><label>19.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kimmerly</surname> <given-names>DS</given-names></name></person-group>. <article-title>A review of human neuroimaging investigations involved with central autonomic regulation of baroreflex-mediated cardiovascular control</article-title>. <source>Auton Neurosci</source>. (<year>2017</year>) <volume>207</volume>:<fpage>10</fpage>&#x2013;<lpage>21</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.autneu.2017.05.008</pub-id>, PMID: <pub-id pub-id-type="pmid">28529059</pub-id></citation></ref>
<ref id="ref20"><label>20.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Reinhard</surname> <given-names>M</given-names></name> <name><surname>Schwarzer</surname> <given-names>G</given-names></name> <name><surname>Briel</surname> <given-names>M</given-names></name> <name><surname>Altamura</surname> <given-names>C</given-names></name> <name><surname>Palazzo</surname> <given-names>P</given-names></name> <name><surname>King</surname> <given-names>A</given-names></name> <etal/></person-group>. <article-title>Cerebrovascular reactivity predicts stroke in high-grade carotid artery disease</article-title>. <source>Neurology</source>. (<year>2014</year>) <volume>83</volume>:<fpage>1424</fpage>&#x2013;<lpage>31</lpage>. doi: <pub-id pub-id-type="doi">10.1212/WNL.0000000000000888</pub-id>, PMID: <pub-id pub-id-type="pmid">25217057</pub-id></citation></ref>
<ref id="ref21"><label>21.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pinho</surname> <given-names>J</given-names></name> <name><surname>Tyurina</surname> <given-names>A</given-names></name> <name><surname>Hartmann</surname> <given-names>C</given-names></name> <name><surname>Audeh</surname> <given-names>OA</given-names></name> <name><surname>Habib</surname> <given-names>P</given-names></name> <name><surname>Abdelnaby</surname> <given-names>R</given-names></name> <etal/></person-group>. <article-title>Point-of-care ultrasound of the common carotid arteries for detection of large vessel occlusion stroke: results of the POCUS-LVO study</article-title>. <source>Eur Stroke J</source>. (<year>2025</year>):<fpage>23969873251315337</fpage>. doi: <pub-id pub-id-type="doi">10.1177/23969873251315337</pub-id>, PMID: <pub-id pub-id-type="pmid">39882581</pub-id></citation></ref>
<ref id="ref22"><label>22.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Joseph</surname> <given-names>J</given-names></name> <name><surname>Sivaprakasam</surname> <given-names>M</given-names></name></person-group>. <article-title>A magnetic plethysmograph probe for local pulse wave velocity measurement</article-title>. <source>IEEE Trans Biomed Circuits Syst</source>. (<year>2017</year>) <volume>11</volume>:<fpage>1065</fpage>&#x2013;<lpage>76</lpage>. doi: <pub-id pub-id-type="doi">10.1109/TBCAS.2017.2733622</pub-id></citation></ref>
<ref id="ref23"><label>23.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wada</surname> <given-names>T</given-names></name> <name><surname>Kodaira</surname> <given-names>K</given-names></name> <name><surname>Fujishiro</surname> <given-names>K</given-names></name> <name><surname>Okamura</surname> <given-names>T</given-names></name></person-group>. <article-title>Correlation of common carotid flow volume measured by ultrasonic quantitative flowmeter with pathological findings</article-title>. <source>Stroke</source>. (<year>1991</year>) <volume>22</volume>:<fpage>319</fpage>&#x2013;<lpage>23</lpage>. doi: <pub-id pub-id-type="doi">10.1161/01.str.22.3.319</pub-id>, PMID: <pub-id pub-id-type="pmid">2003302</pub-id></citation></ref>
<ref id="ref24"><label>24.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Shimada</surname> <given-names>T</given-names></name> <name><surname>Matsubara</surname> <given-names>K</given-names></name> <name><surname>Koyama</surname> <given-names>D</given-names></name> <name><surname>Matsukawa</surname> <given-names>M</given-names></name> <name><surname>Ohsaki</surname> <given-names>M</given-names></name> <name><surname>Kobayashi</surname> <given-names>Y</given-names></name> <etal/></person-group>. <article-title>Development of evaluation system for cerebral artery occlusion in emergency medical services: noninvasive measurement and utilization of pulse waves</article-title>. <source>Sci Rep</source>. (<year>2023</year>) <volume>13</volume>:<fpage>3339</fpage>. doi: <pub-id pub-id-type="doi">10.1038/s41598-023-30229-3</pub-id>, PMID: <pub-id pub-id-type="pmid">36849592</pub-id></citation></ref>
<ref id="ref25"><label>25.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Nabeel</surname> <given-names>PM</given-names></name> <name><surname>Kiran</surname> <given-names>VR</given-names></name> <name><surname>Joseph</surname> <given-names>J</given-names></name> <name><surname>Abhidev</surname> <given-names>VV</given-names></name> <name><surname>Sivaprakasam</surname> <given-names>M</given-names></name></person-group>. <article-title>Local pulse wave velocity: theory, methods, advancements, and clinical applications</article-title>. <source>IEEE Rev Biomed Eng</source>. (<year>2020</year>) <volume>13</volume>:<fpage>74</fpage>&#x2013;<lpage>112</lpage>. doi: <pub-id pub-id-type="doi">10.1109/RBME.2019.2931587</pub-id>, PMID: <pub-id pub-id-type="pmid">31369386</pub-id></citation></ref>
<ref id="ref26"><label>26.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pereira</surname> <given-names>T</given-names></name> <name><surname>Correia</surname> <given-names>C</given-names></name> <name><surname>Cardoso</surname> <given-names>J</given-names></name></person-group>. <article-title>Novel methods for pulse wave velocity measurement</article-title>. <source>J Med Biol Eng</source>. (<year>2015</year>) <volume>35</volume>:<fpage>555</fpage>&#x2013;<lpage>65</lpage>. doi: <pub-id pub-id-type="doi">10.1007/s40846-015-0086-8</pub-id>, PMID: <pub-id pub-id-type="pmid">26500469</pub-id></citation></ref>
<ref id="ref27"><label>27.</label> <citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chen</surname> <given-names>Y</given-names></name> <name><surname>Shen</surname> <given-names>F</given-names></name> <name><surname>Liu</surname> <given-names>J</given-names></name> <name><surname>Yang</surname> <given-names>G-Y</given-names></name></person-group>. <article-title>Arterial stiffness and stroke: de-stiffening strategy, a therapeutic target for stroke</article-title>. <source>Stroke Vasc Neurol</source>. (<year>2017</year>) <volume>2</volume>:<fpage>65</fpage>&#x2013;<lpage>72</lpage>. doi: <pub-id pub-id-type="doi">10.1136/svn-2016-000045</pub-id>, PMID: <pub-id pub-id-type="pmid">28959494</pub-id></citation></ref>
<ref id="ref28"><label>28.</label> <citation citation-type="other"><person-group person-group-type="author"><name><surname>Tsurusaki</surname> <given-names>R</given-names></name> <name><surname>Shimada</surname> <given-names>S</given-names></name> <name><surname>Matsukawa</surname> <given-names>M</given-names></name> <name><surname>Okuno</surname> <given-names>Y</given-names></name> <name><surname>Saito</surname> <given-names>K</given-names></name> <name><surname>Nagatsuka</surname> <given-names>K</given-names></name></person-group>. Measurement of carotid artery pulse wave by piezoelectric sensor-examination of left/right difference. In: <italic>Proceedings of Symposium on Ultrasonic Electronics</italic> (<year>2017</year>).</citation></ref>
</ref-list>
</back>
</article>