<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Neuroinform.</journal-id>
<journal-title>Frontiers in Neuroinformatics</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Neuroinform.</abbrev-journal-title>
<issn pub-type="epub">1662-5196</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fninf.2022.878279</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Neuroinformatics</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>A standardized accelerometry method for characterizing tremor: Application and validation in an ageing population with postural and action tremor</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name><surname>Gauthier-Lafreniere</surname> <given-names>Etienne</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Aljassar</surname> <given-names>Meshal</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Rymar</surname> <given-names>Vladimir V.</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/37128/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Milton</surname> <given-names>John</given-names></name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name><surname>Sadikot</surname> <given-names>Abbas F.</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="corresp" rid="c001"><sup>&#x002A;</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/23018/overview"/>
</contrib>
</contrib-group>
<aff id="aff1"><sup>1</sup><institution>Department of Neurology and Neurosurgery, Montreal Neurological Institute, McGill University Health Centre, McGill University</institution>, <addr-line>Montreal, QC</addr-line>, <country>Canada</country></aff>
<aff id="aff2"><sup>2</sup><institution>Department of Psychiatry, Montreal Neurological Institute, McGill University Health Centre, McGill University</institution>, <addr-line>Montreal, QC</addr-line>, <country>Canada</country></aff>
<aff id="aff3"><sup>3</sup><institution>W.M. Keck Science Department, Claremont Colleges</institution>, <addr-line>Claremont, CA</addr-line>, <country>United States</country></aff>
<author-notes>
<fn fn-type="edited-by"><p>Edited by: Ludovico Minati, Tokyo Institute of Technology, Japan</p></fn>
<fn fn-type="edited-by"><p>Reviewed by: Martin J. McKeown, University of British Columbia, Canada; Roberto Erro, University of Salerno, Italy</p></fn>
<corresp id="c001">&#x002A;Correspondence: Abbas F. Sadikot, <email>abbas.sadikot@mcgill.ca</email></corresp>
</author-notes>
<pub-date pub-type="epub">
<day>04</day>
<month>08</month>
<year>2022</year>
</pub-date>
<pub-date pub-type="collection">
<year>2022</year>
</pub-date>
<volume>16</volume>
<elocation-id>878279</elocation-id>
<history>
<date date-type="received">
<day>18</day>
<month>02</month>
<year>2022</year>
</date>
<date date-type="accepted">
<day>28</day>
<month>06</month>
<year>2022</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x00A9; 2022 Gauthier-Lafreniere, Aljassar, Rymar, Milton and Sadikot.</copyright-statement>
<copyright-year>2022</copyright-year>
<copyright-holder>Gauthier-Lafreniere, Aljassar, Rymar, Milton and Sadikot</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license>
</permissions>
<abstract>
<sec>
<title>Background</title>
<p>Ordinal scales based on qualitative observation are the mainstay in the clinical assessment of tremor, but are limited by inter-rater reliability, measurement precision, range, and ceiling effects. Quantitative tremor evaluation is well-developed in research, but clinical application has lagged, in part due to cumbersome mathematical application and lack of established standards.</p>
</sec>
<sec>
<title>Objectives</title>
<p>To develop a novel method for evaluating tremor that integrates a standardized clinical exam, wrist-watch accelerometers, and a software framework for data analysis that does not require advanced mathematical or computing skills. The utility of the method was tested in a sequential cohort of patients with predominant postural and action tremor presenting to a specialized surgical clinic with the presumptive diagnosis of Essential Tremor (ET).</p>
</sec>
<sec>
<title>Methods</title>
<p>Wristwatch accelerometry was integrated with a standardized clinical exam. A MATLAB application was developed for automated data analysis and graphical representation of tremor. Measures from the power spectrum of acceleration of tremor in different upper limb postures were derived in 25 consecutive patients. The linear results from accelerometry were correlated with the commonly used non-linear Clinical Rating Scale for Tremor (CRST).</p>
</sec>
<sec>
<title>Results</title>
<p>The acceleration power spectrum was reliably produced in all consecutive patients. Tremor frequency was stable in different postures and across patients. Both total and peak power of acceleration during postural conditions correlated well with the CRST. The standardized clinical examination with integrated accelerometry measures was therefore effective at characterizing tremor in a population with predominant postural and action tremor. The protocol is also illustrated on repeated measures in an ET patient who underwent Magnetic Resonance-Guided Focused Ultrasound thalamotomy.</p>
</sec>
<sec>
<title>Conclusion</title>
<p>Quantitative assessment of tremor as a continuous variable using wristwatch accelerometry is readily applicable as a clinical tool when integrated with a standardized clinical exam and a user-friendly software framework for analysis. The method is validated for patients with predominant postural and action tremor, and can be adopted for characterizing tremor of different etiologies with dissemination in a wide variety of clinical and research contexts in ageing populations.</p>
</sec>
</abstract>
<kwd-group>
<kwd>accelerometry</kwd>
<kwd>clinical rating scale</kwd>
<kwd>power spectrum</kwd>
<kwd>Essential Tremor</kwd>
<kwd>sensor</kwd>
<kwd>Parkinson</kwd>
<kwd>thalamotomy</kwd>
<kwd>focused ultrasound (MRgFUS)</kwd>
</kwd-group>
<contract-sponsor id="cn001">Canadian Institutes of Health Research<named-content content-type="fundref-id">10.13039/501100000024</named-content></contract-sponsor>
<counts>
<fig-count count="2"/>
<table-count count="3"/>
<equation-count count="0"/>
<ref-count count="81"/>
<page-count count="14"/>
<word-count count="10273"/>
</counts>
</article-meta>
</front>
<body>
<sec id="S1" sec-type="intro">
<title>Introduction</title>
<p>Essential Tremor (ET) is a common clinically diagnosed involuntary movement disorder with an estimated prevalence of 0.5% overall and 5% in people over age 65 (<xref ref-type="bibr" rid="B10">Clark and Louis, 2018</xref>; <xref ref-type="bibr" rid="B78">Welton et al., 2021</xref>). ET can be sporadic or have a familial genetic component (<xref ref-type="bibr" rid="B78">Welton et al., 2021</xref>). The frequency of postural limb tremor in ET varies between 4 and 12 Hz and is typically between 4 and 6 Hz. ET is usually bilateral and may have a prominent kinetic component. Rest tremor is more characteristic of Parkinson&#x2019;s disease. ET can cause significant incapacity especially during fine motor tasks. The pathophysiology of ET remains unclear. Tremor in ET syndromes may result from abnormal cerebellar output associated with structural and functional changes in cerebellar Purkinje cells or neighboring interneurons, deep cerebellar nuclei, the brainstem including the inferior olive, or olivo-cerebellar connecting tracts (<xref ref-type="bibr" rid="B2">Axelrad et al., 2008</xref>; <xref ref-type="bibr" rid="B58">Paris-Robidas et al., 2012</xref>; <xref ref-type="bibr" rid="B48">Louis and Faust, 2020</xref>; <xref ref-type="bibr" rid="B80">Wu et al., 2021</xref>; <xref ref-type="bibr" rid="B56">Pan and Kuo, 2022</xref>), Other work fails to demonstrate consistent morphological changes (<xref ref-type="bibr" rid="B72">Symanski et al., 2014</xref>; <xref ref-type="bibr" rid="B63">Rajput et al., 2019</xref>). Ultimately, the abnormal tremor rhythms in ET implicate altered cerebello-thalamo-cortical-spinal circuits and can be suppressed using lesions in the motor thalamus (<xref ref-type="bibr" rid="B48">Louis and Faust, 2020</xref>), or pharmacological modulation, including GABAergic or noradrenergic modulators (<xref ref-type="bibr" rid="B30">Ferreira et al., 2019</xref>). Whether ET with its predominant postural and action tremor represents a distinct disease entity or is more a syndrome with heterogeneous etiology remains debated in the absence of large definitive clinicopathological correlative studies (<xref ref-type="bibr" rid="B27">Erro et al., 2022</xref>). Systematic application of objective, standardized and readily applicable measures of tremor are required for better definition of the postural and action tremor spectrum, and ultimately more effective evaluation of new treatments.</p>
<p>In the research setting, an important initial step to characterizing an oscillation such as in ET is to measure its power spectrum (<xref ref-type="bibr" rid="B50">Milton and Ohira, 2021</xref>). The power spectrum provides a quantitative measure of the power in an oscillation as a function of frequency. In contrast to visual ordinal scales used by health care workers to qualitatively rate tremor severity and its impact on quality of life, power spectra derived from sensors provide more objective data with continuous variables (<xref ref-type="bibr" rid="B34">Grimaldi and Manto, 2010</xref>; <xref ref-type="bibr" rid="B24">Elble and McNames, 2016</xref>). For example, power spectra of tremor derived from accelerometers may be useful for monitoring the progress of individual patients, and for evaluating the response of patient populations to drug therapies, deep brain stimulation, or other novel surgical therapies such as thalamic lesions using Magnetic Resonance Imaging guided Focused Ultrasound (MRgFUS) (<xref ref-type="bibr" rid="B17">Duval et al., 2000</xref>; <xref ref-type="bibr" rid="B52">Nistico et al., 2016</xref>; <xref ref-type="bibr" rid="B76">van Brummelen et al., 2020</xref>; <xref ref-type="bibr" rid="B8">Cernera et al., 2021</xref>; <xref ref-type="bibr" rid="B14">Daneault et al., 2021</xref>; <xref ref-type="bibr" rid="B27">Erro et al., 2022</xref>).</p>
<p>A roadblock for the widespread use of the power spectrum in evaluation of tremor in clinical practice is the lack of reliable and standardized methods for acquisition and analysis. For example, results may vary with the anatomical site of transducer placement, type of sensor, whether acquisition is done in a structured clinical exam setting, duration of sampling, potential fluctuations during longer-term spontaneous recording, or variations in spectral analysis (<xref ref-type="bibr" rid="B51">Mostile et al., 2012</xref>; <xref ref-type="bibr" rid="B37">Haubenberger et al., 2016</xref>; <xref ref-type="bibr" rid="B67">Schuhmayer et al., 2017</xref>; <xref ref-type="bibr" rid="B27">Erro et al., 2022</xref>). Here, we present a method that integrates accelerometry with a standardized clinical assessment protocol. Accelerometer wristwatches are used to record upper limb tremor while assuming different postures as part of a structured physical exam similar to that used during the clinical evaluation of tremor. The standardized protocol provides robust and repeatable tremor recordings that are processed with a custom automated analysis framework that includes a user-friendly interface written in MATLAB. The application enables the user to characterize tremor associated with each limb position and is readily integrated into a clinical evaluation. The method yields the acceleration power spectrum of the tremor recording in standard arm postures, and also provides the user with measures of peak frequency, peak power, and total power of the acceleration power spectrum. Signal processing is performed with an intuitive graphical interface that can be adapted to the user&#x2019;s specific needs. The resulting data can be summarized graphically and archived for individual or pooled analyses. The interface is designed to allow efficient application with modest training by a wide variety of users, including specialized researchers, clinicians or allied health personnel who may have little or no programming experience in MATLAB.</p>
<p>The presented method for tremor analysis is applied prospectively in a sequential cohort of patients with postural and action tremor diagnosed with ET in specialized movement disorders clinics and evaluated for surgical treatment. The method is also validated using concomitant evaluation with the commonly used Clinical Rating Scale for Tremor (CRST) (<xref ref-type="bibr" rid="B28">Fahn et al., 1993</xref>; <xref ref-type="bibr" rid="B70">Stacy et al., 2007</xref>; <xref ref-type="bibr" rid="B53">Ondo et al., 2018</xref>). We demonstrate that the standardized accelerometry method provides valid measures of ET, detecting the predominant postural and action components, and distinguishing from rest tremor. The measures also correlate well with CRST scores. The accompanying power spectra from accelerometry provide more precise quantitative estimates of each patient&#x2019;s tremor frequency and severity. To further illustrate clinical application, we demonstrate the utility of the structured protocol in evaluating changes in an ET patient treated with MRgFUS thalamotomy. We propose that integrating wristwatch accelerometry, a standardized clinical exam and a user-friendly software framework provides useful quantitative measures of tremor with results presented as a continuous variable over a broad range. The method can be readily adapted for characterizing tremor of different etiologies in ageing patients, and applied in a wide variety of clinical and research contexts.</p>
</sec>
<sec id="S2" sec-type="materials|methods">
<title>Materials and methods</title>
<sec id="S2.SS1">
<title>Participant demographics</title>
<p>Twenty-five patients (23 right-handed, 2 left-handed; 7 females, 18 males; mean age 70.5 &#x00B1; 6.3, SD) with predominant postural and action tremors were diagnosed with Essential Tremor (ET) in specialized movement disorders clinics. The patients were evaluated sequentially for surgical treatment at the Montreal Neurological Institute and included in the protocol. A control group of six male volunteers with no movement disorders in a matching age range as patients also participated. An illustrative case example of surgical treatment response and longitudinal follow-up of tremor is also presented. All participants provided written consent and were part of a research protocol approved by the McGill University Health Center&#x2019;s Research Ethics Board.</p>
</sec>
<sec id="S2.SS2">
<title>Acquisition protocol</title>
<p>Laboratory grade wristwatches with micro-electromechanical systems (MEMS)-based accelerometers that are widely applied in research (GENEActiv<sup>&#x00A9;</sup> Original, Activinsights&#x2122;, United Kingdom) were used (<xref ref-type="bibr" rid="B59">Pavey et al., 2016</xref>; <xref ref-type="bibr" rid="B65">Sanders et al., 2019</xref>; <xref ref-type="bibr" rid="B14">Daneault et al., 2021</xref>). They record data continuously (up to 100 Hz; &#x00B1;8 Gs acceleration sensing range; 3.9 mG resolution; 0.5 Gb non-volatile memory), are waterproof, rechargeable and equipped with a light-activated silicone photodiode. The accelerometer data was extracted in bin format and converted into cvs tables using GENEActiv<sup>&#x00A9;</sup> software.</p>
<p>Participants were off ET-related medication, caffeine and alcohol for 12 h, and removed upper limb jewelry. The CRST and accelerometry were performed concomitantly to provide time-matched comparisons. Data acquisition and analysis were performed by different investigators, allowing blinded analysis.</p>
<p>For the accelerometry acquisition, two GENEActiv<sup>&#x00A9;</sup> Original watches were secured to either wrist (<xref ref-type="supplementary-material" rid="FS1">Supplementary Figure 1</xref>). The structured clinical examination protocol began with the patient seated comfortably in an armchair. The prescribed positions were rehearsed with the patient prior to the recording, and active instructions were given during the recording. The exam includes: (1) Rest Position: The participant&#x2019;s elbows were flexed, and both forearms were pronated and rested comfortably fully supported on padded armrests. (2) Postural Position: One arm was extended in front of the participant parallel to the floor, with the forearm pronated and fingers extended. The contralateral arm stayed in the rest position. These measures were repeated in the contralateral limb. (3) Postural Position, Bimanual: Both arms were extended. (4) Wing Position, Bimanual: Both arms were abducted at the shoulder, the elbows were flexed and at the same height as the shoulders, with the fingers extended and about an inch apart in front of the chest. (5) Action with Loading: One arm extended fully in front close to a target while the participant held a closed plastic 500 mL water-filled bottle, and performed a to-and-fro motion from the mouth to the target approximately once per second, mimicking a drinking action. The contralateral arm remained in the rest position. Each position was held for 30 s, with intervening 30 s rest periods. About 5&#x2013;15 s of buffer time was provided between each position to allow comfortable changes and to account for re-emergent tremor during postural conditions. A flashlight activated a light sensor in the wristwatch at the start and end of each tremor epoch to allow reliable assignment of positions during analysis (<xref ref-type="supplementary-material" rid="FS1">Supplementary Figures 1</xref>, <xref ref-type="supplementary-material" rid="FS4">4</xref>).</p>
<p>The protocol was repeated 3&#x00D7; to allow for three sampling epochs per active position with 12 rest position epochs. The entire recording session with setup time lasts &#x223C;30 min. The data was downloaded to a computer with GENEActiv<sup>&#x00AE;</sup> software. To allow the app to automatically process useful recording information, the patient identifier, wrist side, watch number, date and time of recording were included in the filename, separated by underscores as in the following example: <italic>patient X_right wrist_watchnumber_2018-07-13 17-27-44.csv</italic>.</p>
<p>Each patient&#x2019;s tremor was assessed by a qualified physician during the same session using the Clinical Rating Scale for Tremor (CRST) (<xref ref-type="bibr" rid="B28">Fahn et al., 1993</xref>; <xref ref-type="bibr" rid="B26">Elias et al., 2016</xref>). The CRST rater was blind to the accelerometry results. Although the CRST does not evaluate tremor in the wing or bimanual positions, they were included in the accelerometry measurement protocol.</p>
</sec>
<sec id="S2.SS3">
<title>Accelerometry analysis</title>
<p>The supplementary section details the method developed for tremor analysis. The narrative includes a description of acquisition of raw data, coding and filtering, sorting of relevant epochs used to generate power spectra, principal component analysis of the acceleration signal, and Fourier analysis to generate the power spectrum of tremor acceleration. In addition, <xref ref-type="supplementary-material" rid="FS1">Supplementary Figures 1</xref>&#x2013;<xref ref-type="supplementary-material" rid="FS3">3</xref> illustrate the acquisition protocol (<xref ref-type="supplementary-material" rid="FS1">Supplementary Figure 1</xref>), conceptual diagram of analysis workflow (<xref ref-type="supplementary-material" rid="FS2">Supplementary Figure 2</xref>), the software platform and graphical user interface (<xref ref-type="supplementary-material" rid="FS3">Supplementary Figure 3</xref>), and final tremor epochs selected for analysis (<xref ref-type="supplementary-material" rid="FS4">Supplementary Figure 4</xref>). A graphical comparison of accelerometry results in ET and control groups (<xref ref-type="supplementary-material" rid="FS5">Supplementary Figure 5</xref>) is provided. Finally, graphical examples are given of three patients with a range of CRST scores and their associated power spectra (<xref ref-type="supplementary-material" rid="FS6">Supplementary Figure 6</xref>).</p>
</sec>
</sec>
<sec id="S3" sec-type="results">
<title>Results</title>
<p>All 25 consecutive Essential Tremor (ET) patients successfully completed the structured protocol and useful accelerometry data was acquired in all cases. Overall, average peak tremor frequency across all positions was 4.57 &#x00B1; 1.8 Hz, SD. Tremor characteristics in each upper extremity position assumed by patients as part of the structured physical examination were analysed separately (<xref ref-type="fig" rid="F1">Figure 1</xref> and <xref ref-type="table" rid="T1">Tables 1</xref>&#x2013;<xref ref-type="table" rid="T3">3</xref>). The average peak frequency was similar in the postural conditions (extended limb, unimanual, 4.78 &#x00B1; 1.23 Hz, SD; extended limb, bimanual, 4.89 &#x00B1; 1.43 Hz; wing position, 4.58 &#x00B1; 1.35 Hz). During action, mean peak frequency (3.81 &#x00B1; 2.02 Hz, SD) was lower, but the difference was not statistically significant (<xref ref-type="table" rid="T1">Table 1</xref>). Frequencies detected at rest (4.78 &#x00B1; 3.03 Hz, SD) were highly variable as reflected in the standard deviation, and analysis of power spectra indicated far lower values of total and peak power at rest compared to postural and action conditions (<xref ref-type="table" rid="T1">Table 1</xref> and <xref ref-type="supplementary-material" rid="FS5">Supplementary Figure 5</xref>), as detailed further below.</p>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption><p>Graphical summary of tremor accelerometry analysis as presented to the user. The combined and individual power spectra for the different postures are shown. Dotted lines represent individual epochs, and full lines represent the average of the three epochs. The first principal component of the accelerometry recording (PC1-58% of the variance) is used to derive and plot measures. TPwr = Total power of acceleration in the 1&#x2013;20 Hz band. Frequency and peak power are also provided in graphs. In this case, the dominant frequency of tremor in the acceleration spectrum is mainly stable in different postures, with a slight reduction in the Wing position (see <xref ref-type="table" rid="T1">Table 1</xref>). TPwr varies significantly, increasing in postural conditions with the highest power from accelerometry at the wrist in the Wing position. The patient&#x2019;s name and date of the recording are anonymized for publication.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fninf-16-878279-g001.tif"/>
</fig>
<table-wrap position="float" id="T1">
<label>TABLE 1</label>
<caption><p>Summary of accelerometry measures.</p></caption>
<table cellspacing="5" cellpadding="5" frame="hsides" rules="groups">
<thead>
<tr>
<td valign="top" align="left"></td>
<td valign="top" align="center" colspan="2">Peak frequency</td>
<td valign="top" align="center" colspan="2">Peak power</td>
<td valign="top" align="center" colspan="2">Total power (1&#x2013;20 Hz)</td>
</tr>
<tr>
<td valign="top" align="left">Position</td>
<td valign="top" align="center" colspan="2">Hz<hr/></td>
<td valign="top" align="center" colspan="2">m<sup>2</sup>/s<sup>4</sup>/Hz<hr/></td>
<td valign="top" align="center" colspan="2">m<sup>2</sup>/s<sup>4</sup><hr/></td>
</tr>
<tr>
<td/>
<td valign="top" align="center">Mean</td>
<td valign="top" align="center">SD</td>
<td valign="top" align="center">Mean</td>
<td valign="top" align="center">SD</td>
<td valign="top" align="center">Mean</td>
<td valign="top" align="center">SD</td>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Rest</td>
<td valign="top" align="center">4.78</td>
<td valign="top" align="center">3.03</td>
<td valign="top" align="center">0.02</td>
<td valign="top" align="center">0.05</td>
<td valign="top" align="center">0.11</td>
<td valign="top" align="center">0.31</td>
</tr>
<tr>
<td valign="top" align="left">Posture</td>
<td valign="top" align="center">4.78</td>
<td valign="top" align="center">1.23</td>
<td valign="top" align="center">1.58</td>
<td valign="top" align="center">4.33</td>
<td valign="top" align="center">1.08</td>
<td valign="top" align="center">2.62</td>
</tr>
<tr>
<td valign="top" align="left">Bimanual</td>
<td valign="top" align="center">4.89</td>
<td valign="top" align="center">1.43</td>
<td valign="top" align="center">1.44</td>
<td valign="top" align="center">3.47</td>
<td valign="top" align="center">0.96</td>
<td valign="top" align="center">2.18</td>
</tr>
<tr>
<td valign="top" align="left">Wing</td>
<td valign="top" align="center">4.58</td>
<td valign="top" align="center">1.35</td>
<td valign="top" align="center">8.37</td>
<td valign="top" align="center">18.7</td>
<td valign="top" align="center">1.9</td>
<td valign="top" align="center">3.94</td>
</tr>
<tr>
<td valign="top" align="left">Action</td>
<td valign="top" align="center">3.81</td>
<td valign="top" align="center">2.02</td>
<td valign="top" align="center">1.33</td>
<td valign="top" align="center">1.46</td>
<td valign="top" align="center">1.88</td>
<td valign="top" align="center">3.67</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn><p>The mean peak frequencies in the different postural positions were similar, with minor reduction in the action position that was not statistically significant. Peak power increases &#x223C;60&#x2013;80 fold in postural and action conditions compared to rest. Peak power increases &#x223C;5 fold in the wing position compared to the arm extended postural condition. Total power increases &#x223C;10 fold in postural conditions (unimanual and bimanual) compared to rest. There is a &#x223C;2 fold increase in total power in the wing and action conditions compared to the arm extended postural condition. SD, Standard Deviation. Power at rest is markedly low compared to postural and action conditions.</p></fn>
</table-wrap-foot>
</table-wrap>
<table-wrap position="float" id="T2">
<label>TABLE 2</label>
<caption><p>Correlations of CRST (Part A) scores with the total power of acceleration (m<sup>2</sup>/s<sup>4</sup>) at the wrist in the dominant arm in the different rest, postural and action conditions.</p></caption>
<table cellspacing="5" cellpadding="5" frame="hsides" rules="groups">
<thead>
<tr>
<td valign="top" align="left"></td>
<td valign="top" align="center" colspan="3">Rest<hr/></td>
<td valign="top" align="center" colspan="3">Posture<hr/></td>
<td valign="top" align="center" colspan="3">Action<hr/></td>
<td valign="top" align="center" colspan="3">Bimanual<hr/></td>
<td valign="top" align="center" colspan="3">Wing<hr/></td>
</tr>
<tr>
<td valign="top" align="left">CRST Part A</td>
<td valign="top" align="center"><italic>r</italic><sub><italic>s</italic></sub></td>
<td valign="top" align="center">95% Cl</td>
<td valign="top" align="center"><italic>P</italic>-value</td>
<td valign="top" align="center"><italic>r</italic><sub><italic>s</italic></sub></td>
<td valign="top" align="center">95% Cl</td>
<td valign="top" align="center"><italic>P</italic>-value</td>
<td valign="top" align="center"><italic>r</italic><sub><italic>s</italic></sub></td>
<td valign="top" align="center">95% Cl</td>
<td valign="top" align="center"><italic>P</italic>-value</td>
<td valign="top" align="center"><italic>r</italic><sub><italic>s</italic></sub></td>
<td valign="top" align="center">95% Cl</td>
<td valign="top" align="center"><italic>P</italic>-value</td>
<td valign="top" align="center"><italic>r</italic><sub><italic>s</italic></sub></td>
<td valign="top" align="center">95% Cl</td>
<td valign="top" align="left"><italic>P</italic>-value</td>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Rest</td>
<td valign="top" align="center">0.352</td>
<td valign="top" align="center">&#x2212;0.062&#x2013;0.662</td>
<td valign="top" align="center">0.0847</td>
<td valign="top" align="center">0.238</td>
<td valign="top" align="center">&#x2212;0.186&#x2013;0.586</td>
<td valign="top" align="center">0.2525</td>
<td valign="top" align="center">0.368</td>
<td valign="top" align="center">&#x2212;0.044&#x2013;0.673</td>
<td valign="top" align="center">0.0703</td>
<td valign="top" align="center"><bold>0.439</bold></td>
<td valign="top" align="center">0.040&#x2013;0.716</td>
<td valign="top" align="center">0.0281<xref ref-type="table-fn" rid="t2fns1">&#x002A;</xref></td>
<td valign="top" align="center">0.266</td>
<td valign="top" align="center">&#x2212;0.156&#x2013;0.606</td>
<td valign="top" align="left">0.1991</td>
</tr>
<tr>
<td valign="top" align="left">Posture</td>
<td valign="top" align="center">0.121</td>
<td valign="top" align="center">&#x2212;0.298&#x2013;0.502</td>
<td valign="top" align="center">0.5635</td>
<td valign="top" align="center"><bold>0.489</bold></td>
<td valign="top" align="center">0.104&#x2013;0.746</td>
<td valign="top" align="center">0.013<xref ref-type="table-fn" rid="t2fns1">&#x002A;</xref></td>
<td valign="top" align="center"><bold>0.588</bold></td>
<td valign="top" align="center">0.239&#x2013;0.802</td>
<td valign="top" align="center">0.002<xref ref-type="table-fn" rid="t2fns1">&#x002A;&#x002A;</xref></td>
<td valign="top" align="center"><bold>0.601</bold></td>
<td valign="top" align="center">0.258&#x2013;0.809</td>
<td valign="top" align="center">0.0015<xref ref-type="table-fn" rid="t2fns1">&#x002A;&#x002A;</xref></td>
<td valign="top" align="center"><bold>0.493</bold></td>
<td valign="top" align="center">0.108&#x2013;0.748</td>
<td valign="top" align="left">0.0123<xref ref-type="table-fn" rid="t2fns1">&#x002A;</xref></td>
</tr>
<tr>
<td valign="top" align="left">Action</td>
<td valign="top" align="center">0.367</td>
<td valign="top" align="center">&#x2212;0.045&#x2013;0.672</td>
<td valign="top" align="center">0.0710</td>
<td valign="top" align="center"><bold>0.601</bold></td>
<td valign="top" align="center">0.258&#x2013;0.809</td>
<td valign="top" align="center">0.0015<xref ref-type="table-fn" rid="t2fns1">&#x002A;&#x002A;</xref></td>
<td valign="top" align="center"><bold>0.689</bold></td>
<td valign="top" align="center">0.393&#x2013;0.855</td>
<td valign="top" align="center">0.0001<xref ref-type="table-fn" rid="t2fns1">&#x002A;&#x002A;&#x002A;</xref></td>
<td valign="top" align="center"><bold>0.567</bold></td>
<td valign="top" align="center">0.210&#x2013;0.790</td>
<td valign="top" align="center">0.0031<xref ref-type="table-fn" rid="t2fns1">&#x002A;&#x002A;</xref></td>
<td valign="top" align="center"><bold>0.490</bold></td>
<td valign="top" align="center">0.105&#x2013;0.747</td>
<td valign="top" align="left">0.0129<xref ref-type="table-fn" rid="t2fns1">&#x002A;</xref></td>
</tr>
<tr>
<td valign="top" align="left">Total</td>
<td valign="top" align="center">0.373</td>
<td valign="top" align="center">&#x2212;0.038&#x2013;0.676</td>
<td valign="top" align="center">0.0662</td>
<td valign="top" align="center"><bold>0.658</bold></td>
<td valign="top" align="center">0.343&#x2013;0.839</td>
<td valign="top" align="center">0.0004<xref ref-type="table-fn" rid="t2fns1">&#x002A;&#x002A;&#x002A;</xref></td>
<td valign="top" align="center"><bold>0.779</bold></td>
<td valign="top" align="center">0.545&#x2013;0.900</td>
<td valign="top" align="center">&#x003C; 0.0001<xref ref-type="table-fn" rid="t2fns1">&#x002A;&#x002A;&#x002A;&#x002A;</xref></td>
<td valign="top" align="center"><bold>0.765</bold></td>
<td valign="top" align="center">0.521&#x2013;0.893</td>
<td valign="top" align="center">&#x003C; 0.0001<xref ref-type="table-fn" rid="t2fns1">&#x002A;&#x002A;&#x002A;&#x002A;</xref></td>
<td valign="top" align="center"><bold>0.609</bold></td>
<td valign="top" align="center">0.269&#x2013;0.813</td>
<td valign="top" align="left">0.0012<xref ref-type="table-fn" rid="t2fns1">&#x002A;&#x002A;</xref></td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="t2fns1"><p>Total power of acceleration in two postural conditions showed moderate (Postural, Unimanual) or strong (Postural, Bimanual) and significant correlations with the corresponding postural CRST scores. Total power of acceleration in the action condition showed strong significant correlation with the corresponding action CRST score. Total power of acceleration in both postural and action conditions showed strong and significant correlations with the corresponding total CRST scores. Results from the wing position were presented as part of the correlation table, but this position was not part of the CRST. Bold font signifies moderate and strong correlations. r<sub><italic>s</italic></sub> is the Spearman correlation coefficient, CI is the confidence interval, the <italic>P</italic>-value is two tailed, &#x002A;<italic>P</italic> &#x003C; 0.05, &#x002A;&#x002A;<italic>P</italic> &#x003C; 0.01, &#x002A;&#x002A;&#x002A;<italic>P</italic> &#x003C; 0.001, &#x002A;&#x002A;&#x002A;&#x002A;<italic>P</italic> &#x003C; 0.0001.</p></fn>
</table-wrap-foot>
</table-wrap>
<table-wrap position="float" id="T3">
<label>TABLE 3</label>
<caption><p>Correlations of CRST (Part A) scores with the peak power of acceleration (m<sup>2</sup>/s<sup>4</sup>) at the wrist in the dominant arm in the different rest, postural and action conditions.</p></caption>
<table cellspacing="5" cellpadding="5" frame="hsides" rules="groups">
<thead>
<tr>
<td valign="top" align="left"></td>
<td valign="top" align="center" colspan="3">Rest<hr/></td>
<td valign="top" align="center" colspan="3">Posture<hr/></td>
<td valign="top" align="center" colspan="3">Action<hr/></td>
<td valign="top" align="center" colspan="3">Bimanual<hr/></td>
<td valign="top" align="center" colspan="3">Wing<hr/></td>
</tr>
<tr>
<td valign="top" align="left">CRST Part A</td>
<td valign="top" align="center"><italic>r</italic><sub><italic>s</italic></sub></td>
<td valign="top" align="center">95% Cl</td>
<td valign="top" align="center"><italic>P</italic>-value</td>
<td valign="top" align="center"><italic>r</italic><sub><italic>s</italic></sub></td>
<td valign="top" align="center">95% Cl</td>
<td valign="top" align="center"><italic>P</italic>-value</td>
<td valign="top" align="center"><italic>r</italic><sub><italic>s</italic></sub></td>
<td valign="top" align="center">95% Cl</td>
<td valign="top" align="center"><italic>P</italic>-value</td>
<td valign="top" align="center"><italic>r</italic><sub><italic>s</italic></sub></td>
<td valign="top" align="center">95% Cl</td>
<td valign="top" align="center"><italic>P</italic>-value</td>
<td valign="top" align="center"><italic>r</italic><sub><italic>s</italic></sub></td>
<td valign="top" align="center">95% Cl</td>
<td valign="top" align="left"><italic>P</italic>-value</td>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Rest</td>
<td valign="top" align="center">0.325</td>
<td valign="top" align="center">&#x2212;0.093&#x2013;0.645</td>
<td valign="top" align="center">0.1134</td>
<td valign="top" align="center">0.327</td>
<td valign="top" align="center">&#x2212;0.090&#x2013;0.646</td>
<td valign="top" align="center">0.1107</td>
<td valign="top" align="center"><bold>0.413</bold></td>
<td valign="top" align="center">0.009&#x2013;0.701</td>
<td valign="top" align="center">0.04<xref ref-type="table-fn" rid="t3fns1">&#x002A;</xref></td>
<td valign="top" align="center"><bold>0.512</bold></td>
<td valign="top" align="center">0.134&#x2013;0.759</td>
<td valign="top" align="center">0.0089<xref ref-type="table-fn" rid="t3fns1">&#x002A;&#x002A;</xref></td>
<td valign="top" align="center">0.357</td>
<td valign="top" align="center">&#x2212;0.056&#x2013;0.666</td>
<td valign="top" align="left">0.0795</td>
</tr>
<tr>
<td valign="top" align="left">Posture</td>
<td valign="top" align="center">0.167</td>
<td valign="top" align="center">&#x2212;0.255&#x2013;0.536</td>
<td valign="top" align="center">0.4242</td>
<td valign="top" align="center"><bold>0.616</bold></td>
<td valign="top" align="center">0.280&#x2013;0.817</td>
<td valign="top" align="center">0.001<xref ref-type="table-fn" rid="t3fns1">&#x002A;&#x002A;</xref></td>
<td valign="top" align="center"><bold>0.628</bold></td>
<td valign="top" align="center">0.298&#x2013;0.823</td>
<td valign="top" align="center">0.0008<xref ref-type="table-fn" rid="t3fns1">&#x002A;&#x002A;&#x002A;</xref></td>
<td valign="top" align="center"><bold>0.691</bold></td>
<td valign="top" align="center">0.395&#x2013;0.856</td>
<td valign="top" align="center">0.0001<xref ref-type="table-fn" rid="t3fns1">&#x002A;&#x002A;&#x002A;</xref></td>
<td valign="top" align="center"><bold>0.564</bold></td>
<td valign="top" align="center">0.205&#x2013;0.789</td>
<td valign="top" align="left">0.0033<xref ref-type="table-fn" rid="t3fns1">&#x002A;&#x002A;</xref></td>
</tr>
<tr>
<td valign="top" align="left">Action</td>
<td valign="top" align="center">0.388</td>
<td valign="top" align="center">&#x2212;0.020&#x2013;0.685</td>
<td valign="top" align="center">0.0552</td>
<td valign="top" align="center"><bold>0.480</bold></td>
<td valign="top" align="center">0.093&#x2013;0.741</td>
<td valign="top" align="center">0.0151<xref ref-type="table-fn" rid="t3fns1">&#x002A;</xref></td>
<td valign="top" align="center"><bold>0.576</bold></td>
<td valign="top" align="center">0.221&#x2013;0.795</td>
<td valign="top" align="center">0.0026<xref ref-type="table-fn" rid="t3fns1">&#x002A;&#x002A;</xref></td>
<td valign="top" align="center"><bold>0.477</bold></td>
<td valign="top" align="center">0.088&#x2013;0.739</td>
<td valign="top" align="center">0.016<xref ref-type="table-fn" rid="t3fns1">&#x002A;</xref></td>
<td valign="top" align="center"><bold>0.429</bold></td>
<td valign="top" align="center">0.028&#x2013;0.710</td>
<td valign="top" align="left">0.0325<xref ref-type="table-fn" rid="t3fns1">&#x002A;</xref></td>
</tr>
<tr>
<td valign="top" align="left">Total</td>
<td valign="top" align="center">0.396</td>
<td valign="top" align="center">&#x2212;0.011&#x2013;0.690</td>
<td valign="top" align="center">0.0500</td>
<td valign="top" align="center"><bold>0.668</bold></td>
<td valign="top" align="center">0.360&#x2013;0.844</td>
<td valign="top" align="center">0.0003<xref ref-type="table-fn" rid="t3fns1">&#x002A;&#x002A;&#x002A;</xref></td>
<td valign="top" align="center"><bold>0.758</bold></td>
<td valign="top" align="center">0.508&#x2013;0.889</td>
<td valign="top" align="center">0.0001<xref ref-type="table-fn" rid="t3fns1">&#x002A;&#x002A;&#x002A;</xref></td>
<td valign="top" align="center"><bold>0.775</bold></td>
<td valign="top" align="center">0.538&#x2013;0.898</td>
<td valign="top" align="center">&#x003C; 0.0001<xref ref-type="table-fn" rid="t3fns1">&#x002A;&#x002A;&#x002A;&#x002A;</xref></td>
<td valign="top" align="center"><bold>0.638</bold></td>
<td valign="top" align="center">0.313&#x2013;0.829</td>
<td valign="top" align="left">0.0006<xref ref-type="table-fn" rid="t3fns1">&#x002A;&#x002A;&#x002A;</xref></td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="t3fns1"><p>Peak power of acceleration in two postural conditions (Postural, Unimanual; Postural, Bimanual) showed strong and significant correlation with the corresponding postural CRST scores. Peak power of acceleration in the action condition, showed moderate and significant correlation with the corresponding action CRST score. Peak power of acceleration in both postural and action conditions showed strong and significant correlations with the corresponding total CRST scores. Results from the wing position are presented as part of the correlation table, but this position is not part of the CRST. Bold font signifies moderate and strong correlations. r<sub><italic>s</italic></sub> is the Spearman&#x2019;s correlation coefficient, CI is the confidence interval, the <italic>P</italic>-value is two tailed, &#x002A;<italic>P</italic> &#x003C; 0.05, &#x002A;&#x002A;<italic>P</italic> &#x003C; 0.01, &#x002A;&#x002A;&#x002A;<italic>P</italic> &#x003C; 0.001, &#x002A;&#x002A;&#x002A;&#x002A;<italic>P</italic> &#x003C; 0.0001.</p></fn>
</table-wrap-foot>
</table-wrap>
<p>In contrast to frequency, the mean total power (1&#x2013;20 Hz) and peak power in the power spectrum of acceleration showed significant variation across different positions (<xref ref-type="table" rid="T1">Table 1</xref>, <xref ref-type="fig" rid="F1">Figure 1</xref> and <xref ref-type="supplementary-material" rid="FS5">Supplementary Figures 5</xref>, <xref ref-type="supplementary-material" rid="FS6">6</xref>). Interestingly, increases were noted in all static postural conditions compared to rest, in keeping with the diagnosis of an ET syndrome. Total and peak power of acceleration was especially accentuated in the wing position. To determine whether the increase in power measured in action was more a reflection of translational artefact due to back-and-forth movement rather than tremor oscillations, control participants (<italic>n</italic> = 6) without clinically detectable tremor performed a similar protocol as ET patients. Mean total power of acceleration in the action with loading condition in controls was 0.09 &#x00B1; 0.03 m<sup>2</sup>/s<sup>4</sup>, which is 21 times lower than in ET patients, indicating that the high level of total power during action in ET patients was mainly a reflection of tremor detected by the accelerometer-based analysis protocol rather than movement alone (<xref ref-type="supplementary-material" rid="FS5">Supplementary Figure 5</xref>). Furthermore, control participants showed peak and total power that was also many magnitudes below that seen in the patients (<xref ref-type="supplementary-material" rid="FS5">Supplementary Figure 5</xref>).</p>
<p>To determine how measures of total power within the 1&#x2013;20 Hz band and peak power compare with a commonly used clinical scale, CRST upper extremity tremor scores were obtained during the same session as accelerometry, as part of the structured protocol. Systematic Spearman&#x2019;s correlations were performed between CRST scores and accelerometry, using measures from the dominant arm. Overall, significant moderate to strong correlations were obtained in postural and action conditions between accelerometry measures and the CRST Part A, which provides a visual assessment of upper extremity tremor (<xref ref-type="table" rid="T2">Tables 2</xref>, <xref ref-type="table" rid="T3">3</xref>). The CRST Part A showed significant moderate to strong correlations with total power of acceleration in both postural conditions (Postural, Unimanual, <italic>r</italic><sub><italic>s</italic></sub> = 0.489, <italic>p</italic> = 0.013<sup>&#x2217;</sup>; Postural, Bimanual, <italic>r</italic><sub><italic>s</italic></sub> = 0.601, <italic>p</italic> = 0.0015<sup>&#x2217;&#x2217;</sup>, see <xref ref-type="table" rid="T2">Table 2</xref>). Peak power of acceleration showed strong significant correlation with CRST Part A scores in both postural conditions (Postural, Unimanual, <italic>r</italic><sub><italic>s</italic></sub> = 0.616, <italic>p</italic> = 0.001<sup>&#x2217;&#x2217;</sup>; Postural, Bimanual, <italic>r</italic><sub><italic>s</italic></sub> = 0.691, <italic>p</italic> = 0.0001<sup>&#x2217;&#x2217;&#x2217;</sup>, see <xref ref-type="table" rid="T3">Table 3</xref>).</p>
<p>Furthermore, in the action condition, the CRST Part A showed strong significant correlation with total power of acceleration (<italic>r</italic><sub><italic>s</italic></sub> = 0.6888, <italic>p</italic> = 0.0001<sup>&#x2217;&#x2217;&#x2217;</sup>, <xref ref-type="table" rid="T2">Table 2</xref>) and a moderate significant correlation with peak of acceleration (<italic>r</italic><sub><italic>s</italic></sub> = 0.5756, <italic>p</italic> = 0.0026<sup>&#x2217;&#x2217;</sup>, <xref ref-type="table" rid="T3">Table 3</xref>). The total CRST part A score showed strong and significant correlations with total and peak power of acceleration in both postural and action conditions as expected for this group of ET patients. Results from the wing position are presented as part of the correlation tables (<xref ref-type="table" rid="T2">Tables 2</xref>, <xref ref-type="table" rid="T3">3</xref>), but this position is not part of the CRST. However, it does appear in other visual clinical scales for ET, including the TETRAS.</p>
<p>Rest tremor was not significant in the majority of patients (<xref ref-type="table" rid="T1">Table 1</xref> and <xref ref-type="supplementary-material" rid="FS5">Supplementary Figure 5</xref>), with expected non-significant weak correlations between CRST Part A scores and power of acceleration. We noted peak power of tremor at rest above the evidently low mean (0.024 m<sup>2</sup>/sec<sup>4</sup> &#x00B1; 0.047, SD) in five patients. In 4 of these 5 cases, the ratio of rest peak power/postural peak power was much less than 1, and in one case it was 1.03. This one patient had the third highest peak power in action, with comparatively low power at rest and during postural conditions. Four patients had total power at rest above the evidently low mean (0.11 m<sup>2</sup>/sec<sup>4</sup> &#x00B1; 0.31, SD), and these cases were within the group of five patients with peak tremor above the mean. Of these, two had a ratio of rest total power/postural total power above 1, and both these cases had high power in action and were classed in the top four in the group of 25. These patients with advanced ET may have been considered as having an &#x201C;ET plus&#x201D; variant according to a recent consensus classification (<xref ref-type="bibr" rid="B5">Bhatia et al., 2018</xref>) although they may also be considered as a variant of advanced ET (<xref ref-type="bibr" rid="B47">Louis et al., 2020</xref>; <xref ref-type="bibr" rid="B40">Iglesias-Hernandez et al., 2021</xref>).</p>
<p>The range of power spectrum outputs typified by different severity of tremor from CRST (Part A) scores, is further illustrated (<xref ref-type="supplementary-material" rid="FS6">Supplementary Figure 6</xref>). We noted the wide range of values captured by accelerometry for different CRST ratings, as evident in variations in the magnitude of the <italic>y</italic>-axes. Thus, power in Example 1, with a low CRST score, is many orders of magnitude smaller than values in Example 3, with a high CRST score. A large measurement range is afforded by accelerometry, and contrasts with the relatively low range of visual scales that limits the appreciation of differences in tremor severity between patients.</p>
<p>To further illustrate the practical utility of an integrated standardized physical exam and accelerometry protocol, we describe the case of a patient who underwent MR-guided Focused Ultrasound Thalamotomy (MRgFUS), an emerging novel treatment for the control of refractory ET (<xref ref-type="fig" rid="F2">Figure 2</xref>). A 76-year-old right-handed male presented with a 25-year history of tremor in both arms. His tremor had worsened during the last 5 years. The tremor severely impaired daily activities such as writing, eating, drinking and dressing, and was resistant to multiple attempts at pharmacological treatment. Tremor in the dominant right arm was treated with a MR-guided Focused Ultrasound lesion in the left thalamic ventral intermediate nucleus (Vim) (<xref ref-type="bibr" rid="B1">Atkinson et al., 2002</xref>; <xref ref-type="bibr" rid="B71">Su et al., 2020</xref>). The structured accelerometry protocol and CRST scale were performed prior to surgery and at each clinical follow-up at 48 h and 1, 3, 6, 12 months after treatment (<xref ref-type="fig" rid="F2">Figure 2</xref>). The patient&#x2019;s right arm tremor was more disabling and showed higher total power. The tremor power spectrum was silenced post-operatively at the right arm, with no re-emergence on serial evaluations up to 1 year after treatment (<xref ref-type="fig" rid="F2">Figure 2</xref>). The patient experienced marked improvement in activities of daily living (eating, drinking from a glass, dressing) and gradually stopped medications for control of tremor. This method can therefore provide valuable information on tremor frequency, tremor power, effects of different postures, and effects of medical interventions on tremor severity that can be followed over time.</p>
<fig id="F2" position="float">
<label>FIGURE 2</label>
<caption><p><bold>(A)</bold> Power Spectra of Acceleration for the right arm (dominant) in the unimanual extended position (Posture) showing successful reduction of tremor after left brain MR-guided focused ultrasound thalamotomy. Time points are prior to surgery (PreOp), and at five intervals after surgery (PostOp). The total power of acceleration in the 1&#x2013;20 Hz band is 7.1 m<sup>2</sup>/s<sup>4</sup> prior to surgery, and consistently &#x003C; 0.01 m<sup>2</sup>/s<sup>4</sup> in subsequent measures spanning 1 year after surgery. <bold>(B)</bold> Power Spectra of Acceleration for the non-operated left arm in the unimanual extended position (Posture) after MR-guided focused ultrasound thalamotomy. The total power of acceleration in the 1&#x2013;20 Hz band is 3.51 m<sup>2</sup>/s<sup>4</sup> prior to surgery, and then 0.197, 0.906, 1.44, 1.79, and 2.72 m<sup>2</sup>/s<sup>4</sup> in subsequent measures spanning 1 year after surgery.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fninf-16-878279-g002.tif"/>
</fig>
</sec>
<sec id="S4" sec-type="discussion">
<title>Discussion</title>
<p>Tremor as a clinical finding is commonly defined as a rhythmic shaking of a body part (<xref ref-type="bibr" rid="B10">Clark and Louis, 2018</xref>; <xref ref-type="bibr" rid="B78">Welton et al., 2021</xref>). Involuntary tremor is generally composed of non-linear, non-stationary roughly sinusoidal oscillatory movements with a symmetric velocity profile about a theoretical midpoint (<xref ref-type="bibr" rid="B35">Grimaldi and Manto, 2013</xref>; <xref ref-type="bibr" rid="B16">Deuschl et al., 2022</xref>). Pathological tremor can produce significant functional disability, limit daily activities and contribute to social withdrawal (<xref ref-type="bibr" rid="B75">Thangavelu et al., 2020</xref>). A wide variety of tremor syndromes can be distinguished by clinical history, associated neurological features, and involvement of different body parts. Physical examination of tremor at rest or with different postural or kinetic conditions allows for visual approximation of tremor frequency and amplitude, and is the mainstay for diagnosis and treatment follow-up (<xref ref-type="bibr" rid="B5">Bhatia et al., 2018</xref>; <xref ref-type="bibr" rid="B78">Welton et al., 2021</xref>). Common pathological tremors include Essential Tremor (ET) (4&#x2013;12 Hz), other types of cerebellum related tremors (2&#x2013;10 Hz) including the irregular and lower frequency Holmes tremor (3&#x2013;5 Hz), rest tremor typically seen in Parkinson&#x2019;s disease (3&#x2013;6 Hz), and the higher frequency orthostatic lower limb tremor (13&#x2013;18 Hz) (<xref ref-type="bibr" rid="B35">Grimaldi and Manto, 2013</xref>; <xref ref-type="bibr" rid="B54">Ondo et al., 2020</xref>; <xref ref-type="bibr" rid="B16">Deuschl et al., 2022</xref>).</p>
<p>One of several visual scales is used for systematic evaluation of tremor in ET, including the Fahn-Tolosa-Marin Tremor Rating Scale (FTM-TRS) (<xref ref-type="bibr" rid="B28">Fahn et al., 1993</xref>) or Clinical Rating Scale for Tremor (CRST) (<xref ref-type="bibr" rid="B70">Stacy et al., 2007</xref>; <xref ref-type="bibr" rid="B26">Elias et al., 2016</xref>), the more recent Tremor Research Group Essential Tremor Rating Assessment Scale (TETRAS) (<xref ref-type="bibr" rid="B19">Elble et al., 2012</xref>; <xref ref-type="bibr" rid="B53">Ondo et al., 2018</xref>; <xref ref-type="bibr" rid="B73">Tarakad, 2020</xref>), the Bain and Findley Clinical Tremor Rating Scale (BF-TRS) and the Glass Scale (<xref ref-type="bibr" rid="B73">Tarakad, 2020</xref>). Since tremor is a continuous variable, ordinal scales are limited by non-linearity, and ceiling and floor effects. Tremor amplitude is not perceived linearly by raters, but rather follows a logarithmic relationship when compared to more objective measures like accelerometry (<xref ref-type="bibr" rid="B25">Elble et al., 2006</xref>; <xref ref-type="bibr" rid="B21">Elble, 2018</xref>). The widely used CRST shows very good internal consistency but suffers from moderate to fair inter-rater reliability, and its 0&#x2013;4 scale of tremor amplitude is susceptible to ceiling effects (<xref ref-type="bibr" rid="B19">Elble et al., 2012</xref>; <xref ref-type="bibr" rid="B43">Lee et al., 2015</xref>). The TETRAS is less susceptible to ceiling effects since it assigns a wider range of tremor amplitudes and shows very good inter-rater reliability (<xref ref-type="bibr" rid="B19">Elble et al., 2012</xref>; <xref ref-type="bibr" rid="B53">Ondo et al., 2018</xref>). The TETRAS also includes the wing posture unlike the CRST, but it requires more training and does not include a rest position (<xref ref-type="bibr" rid="B19">Elble et al., 2012</xref>). Like other visual scales it fails to adequately capture frequency, does not provide a continuous variable, and cannot provide a power spectrum of acceleration. These limitations motivate the development of standardized digital methods that directly quantify tremor displacement or acceleration (<xref ref-type="bibr" rid="B34">Grimaldi and Manto, 2010</xref>; <xref ref-type="bibr" rid="B21">Elble, 2018</xref>; <xref ref-type="bibr" rid="B31">Fitzgerald et al., 2018</xref>). Such standardized quantitative measures of tremor can prove useful for individual patients, and can be archived for analysis in larger-scale clinical trials or longitudinal studies involving multiple evaluators.</p>
<p>A variety of effective but technically intensive methods are described for quantitative evaluation of tremor. These include electromyograms that assess changes in voltage over active muscle groups as a surrogate for tremor amplitude and frequency (<xref ref-type="bibr" rid="B6">Breit et al., 2008</xref>; <xref ref-type="bibr" rid="B81">Zhang et al., 2017</xref>), electromagnetic motion capture (<xref ref-type="bibr" rid="B9">Charles et al., 2017</xref>; <xref ref-type="bibr" rid="B32">Geiger et al., 2018</xref>), laser-based displacement sensors (<xref ref-type="bibr" rid="B17">Duval et al., 2000</xref>) and wearable devices based on accelerometry (<xref ref-type="bibr" rid="B39">Hossen et al., 2013</xref>; <xref ref-type="bibr" rid="B49">Luft et al., 2019</xref>) or gyroscopic measurements of angular speed (<xref ref-type="bibr" rid="B41">Jeon et al., 2017</xref>; <xref ref-type="bibr" rid="B4">Berbakov et al., 2019</xref>). Gyroscopes may be more appropriate compared to accelerometers when measuring movements with a significant angular velocity component such as head tremors (<xref ref-type="bibr" rid="B23">Elble et al., 2017</xref>). Laser-based displacement sensors provide direct measures of tremor amplitude, in contrast to accelerometry or gyroscopic measures, that require derivative calculations to yield amplitude from acceleration. However, laser displacement sensors are limited by portability (<xref ref-type="bibr" rid="B17">Duval et al., 2000</xref>). They are difficult to integrate with the clinical exam and cannot readily measure action tremor. In some cases, multiple modalities are successfully applied, such as combinations of accelerometry and electromyography (<xref ref-type="bibr" rid="B30">Ferreira et al., 2019</xref>; <xref ref-type="bibr" rid="B49">Luft et al., 2019</xref>; <xref ref-type="bibr" rid="B68">Shanker, 2019</xref>). These sophisticated quantitative methods, while effective, are generally not translated from research settings to clinical applications (<xref ref-type="bibr" rid="B31">Fitzgerald et al., 2018</xref>). Accelerometry has gained popularity over other sensors with availability of portable micro-electro-mechanical systems (MEMS) that integrate small transducers with microelectronic circuits for data acquisition and storage (<xref ref-type="bibr" rid="B24">Elble and McNames, 2016</xref>). These sensors allow for the acquisition of quantitative data that include power spectra of acceleration, frequency and derivative measures of amplitude. These measures are advantageous compared to more subjective, non-linear visually guided clinical ratings scales. Despite ready availability, wider dissemination of accelerometers in clinical settings is impaired by a relative paucity of validation in different tremor types, lack of prescribed standardized positions for evaluation of tremor in different body parts, lack of user-friendly freely available analysis software and lack of standards for the wide variety of available transducers (<xref ref-type="bibr" rid="B24">Elble and McNames, 2016</xref>; <xref ref-type="bibr" rid="B37">Haubenberger et al., 2016</xref>; <xref ref-type="bibr" rid="B27">Erro et al., 2022</xref>). Furthermore tremor is posture dependent, varies in different body parts, and fluctuates over time (<xref ref-type="bibr" rid="B11">Cleeves and Findley, 1987</xref>; <xref ref-type="bibr" rid="B51">Mostile et al., 2012</xref>; <xref ref-type="bibr" rid="B67">Schuhmayer et al., 2017</xref>). Thus, there is a need for standardized protocols that effectively integrate accelerometry with the clinical exam, preferably with simultaneous acquisition of a clinical rating scale.</p>
<p>Applications that measure upper extremity tremor with a smartphone that contains accelerometers or gyroscopes and is held in the palm of the hand (<xref ref-type="bibr" rid="B13">Daneault et al., 2012</xref>; <xref ref-type="bibr" rid="B44">Lopez-Blanco et al., 2018</xref>) are cost-effective and readily available. However, wider application is restricted by differences in smartphone brands, the proprietary nature of the hardware and analysis software, lack of standardized evaluation protocols and difficulty adapting handheld devices to conventional clinical exams. Furthermore, tremor characteristics may be modified by the mass and grasp of the handheld device and limit generalizability (<xref ref-type="bibr" rid="B13">Daneault et al., 2012</xref>; <xref ref-type="bibr" rid="B60">Pulliam et al., 2014</xref>; <xref ref-type="bibr" rid="B79">Wile et al., 2014</xref>; <xref ref-type="bibr" rid="B76">van Brummelen et al., 2020</xref>). In contrast, smart-watches do not add a significant weight-loading element, are more readily adapted to the neurological exam, and can serve as a wearable for longer-term evaluation. Analysis of tremor of the upper limb in each of the seven degrees of freedom identifies the wrist as holding the greatest amount of power associated with ET (<xref ref-type="bibr" rid="B9">Charles et al., 2017</xref>; <xref ref-type="bibr" rid="B32">Geiger et al., 2018</xref>), and allows capture of most of the tremor power during the different positions used in a structured clinical exam. Barriers to wider application of wristwatch accelerometers include lack of standardized administration protocols, cumbersome data analysis and sparse validation in clinical practice (<xref ref-type="bibr" rid="B24">Elble and McNames, 2016</xref>). When considering accelerometry as an adjunct to clinical scales, it is important to consider fluctuation of tremor over time (<xref ref-type="bibr" rid="B11">Cleeves and Findley, 1987</xref>; <xref ref-type="bibr" rid="B60">Pulliam et al., 2014</xref>). It is therefore more useful to integrate both the accelerometry and standardized clinical scale assessment during the same session. Here, we incorporated accelerometric measurements into a standardized protocol, with positions generally prescribed during clinical evaluation of tremor, including measures at rest, three different postures (outstretched arm unilateral or bilateral, wing) and action (<xref ref-type="bibr" rid="B77">van de Wardt et al., 2020</xref>). The protocol allowed for efficient accelerometry measurements at the same time as the CRST and can be adapted to other preferred clinical scale assessments used for ET syndromes or other upper limb tremor syndromes.</p>
<p>A variety of affordable consumer grade accelerometer watches provide high sampling rates over sufficient intervals. The watches used in the present study can be set to sampling rates up to 100 Hz with a resolution of 3.8 mG providing adequate precision for digital tremor analysis. While tri-axial acceleration measurements do not provide direct evaluation of tremor amplitude, in contrast to other tools such as laser displacement sensors (<xref ref-type="bibr" rid="B17">Duval et al., 2000</xref>; <xref ref-type="bibr" rid="B7">Carignan et al., 2012</xref>), they provide convenient and useful derivative measures of tremor applicable to diagnosis and research. The acceleration power spectrum enables identification of the peak tremor frequency. This information can contribute to diagnosis by distinguishing lower frequency tremors from high frequency tremors, or in some cases support the diagnosis of a functional tremor when there is no consistent peak (<xref ref-type="bibr" rid="B35">Grimaldi and Manto, 2013</xref>; <xref ref-type="bibr" rid="B46">Louis, 2013</xref>; <xref ref-type="bibr" rid="B36">Hallett, 2016</xref>; <xref ref-type="bibr" rid="B16">Deuschl et al., 2022</xref>). The total power of acceleration and peak power are effective quantitative measures of tremor severity and may be used as an archive for follow-up studies of tremor progression and treatment efficacy (<xref ref-type="bibr" rid="B25">Elble et al., 2006</xref>; <xref ref-type="bibr" rid="B35">Grimaldi and Manto, 2013</xref>; <xref ref-type="bibr" rid="B39">Hossen et al., 2013</xref>; <xref ref-type="bibr" rid="B9">Charles et al., 2017</xref>; <xref ref-type="bibr" rid="B44">Lopez-Blanco et al., 2018</xref>; <xref ref-type="bibr" rid="B49">Luft et al., 2019</xref>; <xref ref-type="bibr" rid="B76">van Brummelen et al., 2020</xref>).</p>
<p>The integrated accelerometry and structured physical exam protocol and custom MATLAB analysis package was successfully implemented in a cohort of clinically well-characterized patients being evaluated for surgery for ET. The method reliably provided tremor frequencies consistent with the diagnosis of ET and identified the predominant tremor postural and action components. The ET cohort had postural (4.78 &#x00B1; 1.23 Hz, SD) and action (3.81 &#x00B1; 2.02, SD) tremor at the lower end of the typical reported range of 4&#x2013;6 Hz (<xref ref-type="bibr" rid="B68">Shanker, 2019</xref>). Since tremor frequency tends to decrease and amplitude increases with disease progression (<xref ref-type="bibr" rid="B20">Elble, 2000</xref>; <xref ref-type="bibr" rid="B38">Hellwig et al., 2009</xref>; <xref ref-type="bibr" rid="B35">Grimaldi and Manto, 2013</xref>), the observed frequencies likely reflect the advanced disease state of this medically resistant surgical cohort. Interestingly, tremor frequency is similar in all postural positions, which suggests the predominant influence of central networks as generators with peripheral proprioceptive modulation (<xref ref-type="bibr" rid="B17">Duval et al., 2000</xref>; <xref ref-type="bibr" rid="B62">Raethjen and Deuschl, 2012</xref>). Tremor amplitude is a major determinant of disability and is reflected in the power spectrum of tremor. Whereas frequency is similar in different positions, the marked increase in power in posture and action conditions compared to rest (<xref ref-type="supplementary-material" rid="FS5">Supplementary Figures 5</xref>, <bold>6</bold>) is consistent with ET and provides an index of disability. Peak power of tremor correlates best with CRST Part A scores (<xref ref-type="table" rid="T3">Table 3</xref>), which is expected, since peak power reflects tremor intensity at its dominant frequency. The wing position is included in scales designed for ET such as the TETRAS. The algorithm demonstrated that the wing position enhanced tremor, in keeping with other work with ET patients, especially those that systematically apply the TETRAS (<xref ref-type="bibr" rid="B54">Ondo et al., 2020</xref>). Total power of tremor also tends to be higher in the kinetic/action condition compared to when the arm is extended, reflecting clinical observations in ET (<xref ref-type="bibr" rid="B46">Louis, 2013</xref>; <xref ref-type="bibr" rid="B54">Ondo et al., 2020</xref>).</p>
<p>Overall, the present cohort had low power at rest compared to postural and action tremor. Notably, total power at rest was above the mean in four cases. A recently introduced classification considers ET as a tremor syndrome rather than a disease (<xref ref-type="bibr" rid="B5">Bhatia et al., 2018</xref>). An &#x201C;ET plus&#x201D; category is added to account for patients with other neurological signs such as impaired tandem gait, possible dystonic posturing, memory impairment, rest tremor or &#x201C;soft signs&#x201D; of uncertain clinical significance. Inclusion of a distinct ET plus category for patients with rest tremor has generated some controversy, in part due to previous work suggesting that ET patients can have rest tremor especially in advanced stages and at long duration (<xref ref-type="bibr" rid="B74">Tarakad and Jankovic, 2018</xref>; <xref ref-type="bibr" rid="B29">Fearon et al., 2019</xref>; <xref ref-type="bibr" rid="B22">Elble, 2020</xref>; <xref ref-type="bibr" rid="B47">Louis et al., 2020</xref>; <xref ref-type="bibr" rid="B57">Pandey et al., 2020</xref>). Indeed, since measures adopted for ET such as the TETRAS do not consider rest tremor, some studies may underestimate its prevalence in ET. Furthermore, the test-retest reliability for rest tremor in patients with &#x201C;ET plus&#x201D; is poor (<xref ref-type="bibr" rid="B53">Ondo et al., 2018</xref>). In the present cohort, patients with significant rest tremor also had higher values of total power in the action condition, and may represent a more advanced group of ET tremors, or could be classified as &#x201C;ET plus&#x201D; (<xref ref-type="bibr" rid="B5">Bhatia et al., 2018</xref>; <xref ref-type="bibr" rid="B40">Iglesias-Hernandez et al., 2021</xref>).</p>
<p>More objective measures of tremor with sensors can be applied in a manner that is agnostic to &#x201C;disease&#x201D; classification or etiology, and help characterize a tremor syndrome, which can then be associated with presumptive disease entities. By incorporating the prescribed accelerometry positions into a standardized clinical exam the present wrist accelerometry method is designed to mitigate variability in sensor output due to differences in application by different observers. The method can integrate accelerometry measures in different upper extremity positions with well-used clinical scales, providing objective and continuous variables that assist in defining tremor-associated phenotypes of patients in the clinic or for research purposes. Characterisation of tremor spectra based on sensors therefore does not rely on fluid categories whose pathological basis has yet to be precisely defined. Additional work on subtypes of the ET syndrome (<xref ref-type="bibr" rid="B22">Elble, 2020</xref>; <xref ref-type="bibr" rid="B3">Becktepe et al., 2021</xref>; <xref ref-type="bibr" rid="B33">Gionco et al., 2021</xref>; <xref ref-type="bibr" rid="B40">Iglesias-Hernandez et al., 2021</xref>), with objective characterisation of tremor in different positions and over time, may provide better insight into the ET spectrum. Correlation of these cohorts evaluated with standardized methods at single or multiple centers with brain imaging and eventual post-mortem studies will better define disease entities within the tremor spectrum.</p>
<p>As proof of principle, the evaluation protocol was also applied in a patient with medically intractable ET prior to MRgFUS thalamotomy and during subsequent postoperative follow-up examinations. The patient underwent ventral intermediate nucleus (Vim) thalamotomy (<xref ref-type="bibr" rid="B66">Schaltenbrand et al., 1977</xref>), targeting an area within the posterior part of the ventral lateral nucleus (VLp) of the thalamus (<xref ref-type="bibr" rid="B42">Jones, 2007</xref>). The standardized accelerometry protocol quantified tremor before surgery, the marked reduction after surgery, and the persistent tremor relief on repeated measurements over a year. The method may be widely applied to determine effectiveness of novel approaches in individuals or groups, including MRgFUS, deep brain stimulation surgery, open thalamotomy or other medical treatments for tremor.</p>
<p>The standardized protocol was readily followed despite language barriers or mild cognitive dysfunction in some patients. The software framework allowed reliable extraction of tremor metrics, including the acceleration power spectrum, peak frequency, peak amplitude, total power of tremor, and graphical tremor profiles. Data extraction requires a computer interface and some technical knowledge that is readily acquired. Several steps would further validate and advance the present methodology. First, inter-rater reliability of the protocol could be compared in different clinical and research domains. This would include refinement of the open-source user-friendly software framework in wider field application by different caregivers, researchers or allied health professionals. Second, heterogeneous tremor types could be tested. Third, the software framework could be tested using data from different accelerometer wristwatches, enabling broader applicability. Fourth, a comparison with other digital acquisition methods such as EMG or laser displacement sensors would be useful, although the portability and ease of use of accelerometer watches is a distinct advantage. Fifth, accelerometer-based methodology may be adapted to other body parts. Finally, while standardized accelerometry with wearable sensors can provide an excellent snapshot of tremor characteristics in controlled environments (<xref ref-type="bibr" rid="B12">Dai et al., 2015</xref>; <xref ref-type="bibr" rid="B55">Pan et al., 2015</xref>; <xref ref-type="bibr" rid="B15">Delrobaei et al., 2018</xref>; <xref ref-type="bibr" rid="B45">L&#x00F3;pez-Blanco et al., 2019</xref>), future development may include measures of tremor in diverse environments such as in-home contexts. However, long term task independent monitoring of tremor remains challenging in view of data storage requirements, and a lack of readily available protocols for analysis of tremor in freely moving limbs (<xref ref-type="bibr" rid="B64">Salarian et al., 2007</xref>; <xref ref-type="bibr" rid="B61">Pulliam et al., 2018</xref>).</p>
<p>In summary, we present a novel accelerometry-based structured protocol that provides objective, reliable, and reproducible measures of upper extremity tremor, distinguishing rest, postural and action components. Accelerometry provides a continuous variable, with measures of frequency and derivatives of the power spectrum that reflect tremor intensity. Since the algorithm combines digital tools with a standardized protocol that mirrors a commonly applied physical examination, it can be readily adapted to the clinic. Systematic use in the clinic will provide a basis for rational interpretation of variations in tremor as part of natural history or in response to novel therapies (<xref ref-type="bibr" rid="B69">Sharma and Pandey, 2020</xref>; <xref ref-type="bibr" rid="B27">Erro et al., 2022</xref>). The suggested standardized clinical evaluation protocol can be readily integrated with clinical tremor scales (e.g., CRST or TETRAS), providing additional information on the impact of tremor on daily functions such as handwriting, and results of the spiral and line drawings that are especially sensitive to postural and kinetic tremors. Since tremor syndromes are defined using multiple clinical criteria such as onset, evolution, family history, body part involved and possible etiology (<xref ref-type="bibr" rid="B5">Bhatia et al., 2018</xref>; <xref ref-type="bibr" rid="B78">Welton et al., 2021</xref>), digital assessment tools cannot replace clinical tremor assessment scores and quality of life assessments (<xref ref-type="bibr" rid="B18">Elble et al., 2013</xref>; <xref ref-type="bibr" rid="B73">Tarakad, 2020</xref>). Rather, they serve as an important adjunct to the clinical exam, providing a comprehensive evaluation of tremor and a useful approach for harmonizing with research-based methods. Future work will determine generalizability of the method for evaluation of other tremor types, including Parkinson&#x2019;s disease and related conditions.</p>
</sec>
<sec id="S5" sec-type="data-availability">
<title>Data availability statement</title>
<p>The data that support the findings of this study are available from the corresponding author, upon reasonable request.</p>
</sec>
<sec id="S6">
<title>Ethics statement</title>
<p>The studies involving human participants were reviewed and approved by the McGill University Health Centre Institutional Review Board. The patients/participants provided their written informed consent to participate in this study.</p>
</sec>
<sec id="S7">
<title>Author contributions</title>
<p>EG-L developed the software, performed the analysis, helped with protocol design, and wrote initial draft of manuscript and participated in writing final version. MA developed clinical evaluation protocol and data acquisition method, reviewed and helped implement software application, helped write initial and final drafts of manuscript, and participated in writing final version. VR helped with statistical analysis, and reviewed final drafts of manuscript. JM reviewed the applied mathematics and data analysis, and helped write final version of manuscript. AS supervised the project, obtained research funding, helped conceive project plan and protocol, helped with participant recruitment, reviewed software development and helped with implementation, helped with data analysis, helped write and supervise final versions of manuscript with input from all collaborators. All authors contributed to the article and approved the submitted version.</p>
</sec>
</body>
<back>
<sec id="S8" sec-type="funding-information">
<title>Funding</title>
<p>This work was supported by the Canadian Institutes of Health Research (CIHR, Grant No. MOP-142324) and the Natural Sciences and Engineering Research Council of Canada (NSERC, Grant No. RPIN-2021-03853), Healthy Brains for Healthy Lives, and the Weston Brain Institute.</p>
</sec>
<sec id="S10" sec-type="COI-statement">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec id="S11" sec-type="disclaimer">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<sec id="S9" sec-type="supplementary-material">
<title>Supplementary material</title>
<p>The Supplementary Material for this article can be found online at: <ext-link ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/fninf.2022.878279/full#supplementary-material">https://www.frontiersin.org/articles/10.3389/fninf.2022.878279/full#supplementary-material</ext-link></p>
<supplementary-material xlink:href="Image_1.tiff" id="FS1" mimetype="image/tiff" xmlns:xlink="http://www.w3.org/1999/xlink">
<label>Supplementary Figure 1</label>
<caption><p><bold>(A)</bold> Timeline of standardized protocol used to record tremor in different upper limb positions during wristwatch based accelerometry. Data acquisition is performed sequentially at rest, then with with one arm extended (Posture Unimanual), followed by extension of the contralateral arm, bimanual arm extension (Posture Bimanual), bimanual wing position (Wing), and finally with either arm moving with a to and fro drinking motion whilst holding a 500 mL water filled plastic bottle (Action). One or two signals were applied to activate the light sensor on the wristwatch, signaling the start or end of different standardized postural conditions. <bold>(B)</bold> Resulting raw data from the acquisition. Blue, yellow, and orange traces represent detrended x,y,z accelerometry data. Red trace represents luminosity (lux), used as an event marker.</p></caption>
</supplementary-material>
<supplementary-material xlink:href="Image_2.tiff" id="FS2" mimetype="image/tiff" xmlns:xlink="http://www.w3.org/1999/xlink">
<label>Supplementary Figure 2</label>
<caption><p>Conceptual diagram of the analysis workflow from data acquisition (solid vertical line and bounding boxes) to analysis (chevron-pattern vertical line and interrupted boxes). Watch logo represents steps using GeneActiv<sup>&#x00A9;</sup> accelerometer watches and accompanying software. Laptop logo represents steps using the customized application created in MatLab, designed for tremor analysis (see <xref ref-type="supplementary-material" rid="FS3">Supplementary Figure 3</xref>).</p></caption>
</supplementary-material>
<supplementary-material xlink:href="Image_3.tiff" id="FS3" mimetype="image/tiff" xmlns:xlink="http://www.w3.org/1999/xlink">
<label>Supplementary Figure 3</label>
<caption><p><bold>(A)</bold> Graphical user interface (GUI) visualized upon launch of the MatLab application (Tremor App). Basic analysis settings (dashed box) can be verified and changed. Advanced settings (dotted box) including features such as filter design and principal component visuals can also be accessed by the user. The settings come pre-set for the methods used in the current paper. One accelerometry.csv file must be loaded prior to analysis. <bold>(B)</bold> Tremor App GUI after successful loading of.csv file, showing the file details (dashed box). The analysis routine is automatically performed as per the Methods section following activation by the Run button, which prompts the user to select protocol epochs identified by light signals as a guide. Once performed, the analysis can be visualized as a summary figure (see <xref ref-type="fig" rid="F1">Figure 1</xref> and <xref ref-type="supplementary-material" rid="FS6">Supplementary Figure 6</xref>) or saved for later use in a MatLab structure using the Save Data button.</p></caption>
</supplementary-material>
<supplementary-material xlink:href="Image_4.tiff" id="FS4" mimetype="image/tiff" xmlns:xlink="http://www.w3.org/1999/xlink">
<label>Supplementary Figure 4</label>
<caption><p>Final tremor epochs from a full recording captured by the right arm accelerometer are presented to the user for manual validation. The protocol was repeated three times for a total of 12 active positions (three for each posture) with 12 intervening rest epochs of 10 s each. These selected epochs are then used to calculate and present the corresponding acceleration power spectra.</p></caption>
</supplementary-material>
<supplementary-material xlink:href="Image_5.tiff" id="FS5" mimetype="image/tiff" xmlns:xlink="http://www.w3.org/1999/xlink">
<label>Supplementary Figure 5</label>
<caption><p>Comparison of accelerometry results in the ET group vs. controls for the dominant arm. In ET, the total power increases in different postural conditions compared to rest, with the highest average power noted in this case in the Wing and Action conditions. The ET population shows significant variability between patients in both total power and peak power of acceleration (error bars, SEM), reflecting different tremor intensities between patients.</p></caption>
</supplementary-material>
<supplementary-material xlink:href="Image_6.tiff" id="FS6" mimetype="image/tiff" xmlns:xlink="http://www.w3.org/1999/xlink">
<label>Supplementary Figure 6</label>
<caption><p>Examples of three single patients with varying CRTS (Part A) tremor scores and their corresponding acceleration power spectra. Each power spectrum is the post Fourier transform average of the three epochs comprised in one recording. Note the wide range of values of power with CRST increments, reflected in the changing <italic>y</italic>-axes. As patients develop higher tremor power, we observe the appearance of harmonics, which is a property often observed in oscillating systems.</p></caption>
</supplementary-material>
<supplementary-material xlink:href="Data_Sheet_1.PDF" id="DS1" mimetype="application/pdf" xmlns:xlink="http://www.w3.org/1999/xlink"/>
</sec>
<ref-list>
<title>References</title>
<ref id="B1"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Atkinson</surname> <given-names>J. D.</given-names></name> <name><surname>Collins</surname> <given-names>D. L.</given-names></name> <name><surname>Bertrand</surname> <given-names>G.</given-names></name> <name><surname>Peters</surname> <given-names>T. M.</given-names></name> <name><surname>Pike</surname> <given-names>G. B.</given-names></name> <name><surname>Sadikot</surname> <given-names>A. F.</given-names></name></person-group> (<year>2002</year>). <article-title>Optimal location of thalamotomy lesions for tremor associated with Parkinson disease: a probabilistic analysis based on postoperative magnetic resonance imaging and an integrated digital atlas.</article-title> <source><italic>J. Neurosurg.</italic></source> <volume>96</volume> <fpage>854</fpage>&#x2013;<lpage>866</lpage>. <pub-id pub-id-type="doi">10.3171/jns.2002.96.5.0854</pub-id> <pub-id pub-id-type="pmid">12005392</pub-id></citation></ref>
<ref id="B2"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Axelrad</surname> <given-names>J. E.</given-names></name> <name><surname>Louis</surname> <given-names>E. D.</given-names></name> <name><surname>Honig</surname> <given-names>L. S.</given-names></name> <name><surname>Flores</surname> <given-names>I.</given-names></name> <name><surname>Ross</surname> <given-names>G. W.</given-names></name> <name><surname>Pahwa</surname> <given-names>R.</given-names></name><etal/></person-group> (<year>2008</year>). <article-title>Reduced Purkinje cell number in essential tremor: a postmortem study.</article-title> <source><italic>Arch. Neurol.</italic></source> <volume>65</volume> <fpage>101</fpage>&#x2013;<lpage>107</lpage>. <pub-id pub-id-type="doi">10.1001/archneurol.2007.8</pub-id> <pub-id pub-id-type="pmid">18195146</pub-id></citation></ref>
<ref id="B3"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Becktepe</surname> <given-names>J.</given-names></name> <name><surname>Govert</surname> <given-names>F.</given-names></name> <name><surname>Balint</surname> <given-names>B.</given-names></name> <name><surname>Schlenstedt</surname> <given-names>C.</given-names></name> <name><surname>Bhatia</surname> <given-names>K.</given-names></name> <name><surname>Elble</surname> <given-names>R.</given-names></name><etal/></person-group> (<year>2021</year>). <article-title>Exploring interrater disagreement on essential tremor using a standardized tremor elements assessment.</article-title> <source><italic>Mov. Disord. Clin. Pract.</italic></source> <volume>8</volume> <fpage>371</fpage>&#x2013;<lpage>376</lpage>. <pub-id pub-id-type="doi">10.1002/mdc3.13150</pub-id> <pub-id pub-id-type="pmid">33816665</pub-id></citation></ref>
<ref id="B4"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Berbakov</surname> <given-names>L.</given-names></name> <name><surname>Jovanovic</surname> <given-names>C.</given-names></name> <name><surname>Svetel</surname> <given-names>M.</given-names></name> <name><surname>Vasiljevic</surname> <given-names>J.</given-names></name> <name><surname>Dimic</surname> <given-names>G.</given-names></name> <name><surname>Radulovic</surname> <given-names>N.</given-names></name></person-group> (<year>2019</year>). <article-title>Quantitative assessment of head tremor in patients with essential tremor and cervical dystonia by using inertial sensors.</article-title> <source><italic>Sensors</italic></source> <volume>19</volume>:<fpage>4246</fpage>. <pub-id pub-id-type="doi">10.3390/s19194246</pub-id> <pub-id pub-id-type="pmid">31574913</pub-id></citation></ref>
<ref id="B5"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bhatia</surname> <given-names>K. P.</given-names></name> <name><surname>Bain</surname> <given-names>P.</given-names></name> <name><surname>Bajaj</surname> <given-names>N.</given-names></name> <name><surname>Elble</surname> <given-names>R. J.</given-names></name> <name><surname>Hallett</surname> <given-names>M.</given-names></name> <name><surname>Louis</surname> <given-names>E. D.</given-names></name><etal/></person-group> (<year>2018</year>). <article-title>Consensus Statement on the classification of tremors. from the task force on tremor of the International Parkinson and Movement Disorder Society.</article-title> <source><italic>Mov. Disord.</italic></source> <volume>33</volume> <fpage>75</fpage>&#x2013;<lpage>87</lpage>. <pub-id pub-id-type="doi">10.1002/mds.27121</pub-id> <pub-id pub-id-type="pmid">29193359</pub-id></citation></ref>
<ref id="B6"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Breit</surname> <given-names>S.</given-names></name> <name><surname>Spieker</surname> <given-names>S.</given-names></name> <name><surname>Schulz</surname> <given-names>J. B.</given-names></name> <name><surname>Gasser</surname> <given-names>T.</given-names></name></person-group> (<year>2008</year>). <article-title>Long-term EMG recordings differentiate between parkinsonian and essential tremor.</article-title> <source><italic>J. Neurol.</italic></source> <volume>255</volume> <fpage>103</fpage>&#x2013;<lpage>111</lpage>. <pub-id pub-id-type="doi">10.1007/s00415-008-0712-2</pub-id> <pub-id pub-id-type="pmid">18204805</pub-id></citation></ref>
<ref id="B7"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Carignan</surname> <given-names>B.</given-names></name> <name><surname>Daneault</surname> <given-names>J. F.</given-names></name> <name><surname>Duval</surname> <given-names>C.</given-names></name></person-group> (<year>2012</year>). <article-title>The organization of upper limb physiological tremor.</article-title> <source><italic>Eur. J. Appl. Physiol.</italic></source> <volume>112</volume> <fpage>1269</fpage>&#x2013;<lpage>1284</lpage>. <pub-id pub-id-type="doi">10.1007/s00421-011-2080-3</pub-id> <pub-id pub-id-type="pmid">21785861</pub-id></citation></ref>
<ref id="B8"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Cernera</surname> <given-names>S.</given-names></name> <name><surname>Alcantara</surname> <given-names>J. D.</given-names></name> <name><surname>Opri</surname> <given-names>E.</given-names></name> <name><surname>Cagle</surname> <given-names>J. N.</given-names></name> <name><surname>Eisinger</surname> <given-names>R. S.</given-names></name> <name><surname>Boogaart</surname> <given-names>Z.</given-names></name><etal/></person-group> (<year>2021</year>). <article-title>Wearable sensor-driven responsive deep brain stimulation for essential tremor.</article-title> <source><italic>Brain Stimul.</italic></source> <volume>14</volume> <fpage>1434</fpage>&#x2013;<lpage>1443</lpage>. <pub-id pub-id-type="doi">10.1016/j.brs.2021.09.002</pub-id> <pub-id pub-id-type="pmid">34547503</pub-id></citation></ref>
<ref id="B9"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Charles</surname> <given-names>S. K.</given-names></name> <name><surname>Geiger</surname> <given-names>D. W.</given-names></name> <name><surname>Davidson</surname> <given-names>A. D.</given-names></name> <name><surname>Pigg</surname> <given-names>A. C.</given-names></name> <name><surname>Curtis</surname> <given-names>C. P.</given-names></name> <name><surname>Allen</surname> <given-names>B. C.</given-names></name></person-group> (<year>2017</year>). <article-title>Toward quantitative characterization of essential tremor for future tremor suppression.</article-title> <source><italic>IEEE Int. Conf. Rehabil. Robot.</italic></source> <volume>2017</volume> <fpage>175</fpage>&#x2013;<lpage>180</lpage>. <pub-id pub-id-type="doi">10.1109/ICORR.2017.8009242</pub-id> <pub-id pub-id-type="pmid">28813814</pub-id></citation></ref>
<ref id="B10"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Clark</surname> <given-names>L. N.</given-names></name> <name><surname>Louis</surname> <given-names>E. D.</given-names></name></person-group> (<year>2018</year>). <article-title>Essential tremor.</article-title> <source><italic>Handb. Clin. Neurol.</italic></source> <volume>147</volume> <fpage>229</fpage>&#x2013;<lpage>239</lpage>. <pub-id pub-id-type="doi">10.1016/B978-0-444-63233-3.00015-4</pub-id> <pub-id pub-id-type="pmid">29325613</pub-id></citation></ref>
<ref id="B11"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Cleeves</surname> <given-names>L.</given-names></name> <name><surname>Findley</surname> <given-names>L. J.</given-names></name></person-group> (<year>1987</year>). <article-title>Variability in amplitude of untreated essential tremor.</article-title> <source><italic>J. Neurol. Neurosurg. Psychiatry</italic></source> <volume>50</volume> <fpage>704</fpage>&#x2013;<lpage>708</lpage>. <pub-id pub-id-type="doi">10.1136/jnnp.50.6.704</pub-id> <pub-id pub-id-type="pmid">3612150</pub-id></citation></ref>
<ref id="B12"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dai</surname> <given-names>H.</given-names></name> <name><surname>Zhang</surname> <given-names>P.</given-names></name> <name><surname>Lueth</surname> <given-names>T. C.</given-names></name></person-group> (<year>2015</year>). <article-title>Quantitative assessment of parkinsonian tremor based on an inertial measurement unit.</article-title> <source><italic>Sensors</italic></source> <volume>15</volume> <fpage>25055</fpage>&#x2013;<lpage>25071</lpage>. <pub-id pub-id-type="doi">10.3390/s151025055</pub-id> <pub-id pub-id-type="pmid">26426020</pub-id></citation></ref>
<ref id="B13"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Daneault</surname> <given-names>J. F.</given-names></name> <name><surname>Carignan</surname> <given-names>B.</given-names></name> <name><surname>Cod&#x00E8;re</surname> <given-names>C.</given-names></name> <name><surname>Sadikot</surname> <given-names>A. F.</given-names></name> <name><surname>Duval</surname> <given-names>C.</given-names></name></person-group> (<year>2012</year>). <article-title>Using a smart phone as a standalone platform for detection and monitoring of pathological tremors.</article-title> <source><italic>Front. Hum. Neurosci.</italic></source> <volume>6</volume>:<fpage>357</fpage>. <pub-id pub-id-type="doi">10.3389/fnhum.2012.00357</pub-id> <pub-id pub-id-type="pmid">23346053</pub-id></citation></ref>
<ref id="B14"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Daneault</surname> <given-names>J. F.</given-names></name> <name><surname>Vergara-Diaz</surname> <given-names>G.</given-names></name> <name><surname>Parisi</surname> <given-names>F.</given-names></name> <name><surname>Admati</surname> <given-names>C.</given-names></name> <name><surname>Alfonso</surname> <given-names>C.</given-names></name> <name><surname>Bertoli</surname> <given-names>M.</given-names></name><etal/></person-group> (<year>2021</year>). <article-title>Accelerometer data collected with a minimum set of wearable sensors from subjects with Parkinson&#x2019;s disease.</article-title> <source><italic>Sci. Data</italic></source> <volume>8</volume>:<fpage>48</fpage>. <pub-id pub-id-type="doi">10.1038/s41597-021-00830-0</pub-id> <pub-id pub-id-type="pmid">33547309</pub-id></citation></ref>
<ref id="B15"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Delrobaei</surname> <given-names>M.</given-names></name> <name><surname>Memar</surname> <given-names>S.</given-names></name> <name><surname>Pieterman</surname> <given-names>M.</given-names></name> <name><surname>Stratton</surname> <given-names>T. W.</given-names></name> <name><surname>Mcisaac</surname> <given-names>K.</given-names></name> <name><surname>Jog</surname> <given-names>M.</given-names></name></person-group> (<year>2018</year>). <article-title>Towards remote monitoring of Parkinson&#x2019;s disease tremor using wearable motion capture systems.</article-title> <source><italic>J. Neurol. Sci.</italic></source> <volume>384</volume> <fpage>38</fpage>&#x2013;<lpage>45</lpage>. <pub-id pub-id-type="doi">10.1016/j.jns.2017.11.004</pub-id> <pub-id pub-id-type="pmid">29249375</pub-id></citation></ref>
<ref id="B16"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Deuschl</surname> <given-names>G.</given-names></name> <name><surname>Becktepe</surname> <given-names>J. S.</given-names></name> <name><surname>Dirkx</surname> <given-names>M.</given-names></name> <name><surname>Haubenberger</surname> <given-names>D.</given-names></name> <name><surname>Hassan</surname> <given-names>A.</given-names></name> <name><surname>Helmich</surname> <given-names>R. C.</given-names></name><etal/></person-group> (<year>2022</year>). <article-title>The clinical and electrophysiological investigation of tremor.</article-title> <source><italic>Clin. Neurophysiol.</italic></source> <volume>136</volume> <fpage>93</fpage>&#x2013;<lpage>129</lpage>. <pub-id pub-id-type="doi">10.1016/j.clinph.2022.01.004</pub-id> <pub-id pub-id-type="pmid">35149267</pub-id></citation></ref>
<ref id="B17"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Duval</surname> <given-names>C.</given-names></name> <name><surname>Panisset</surname> <given-names>M.</given-names></name> <name><surname>Bertrand</surname> <given-names>G.</given-names></name> <name><surname>Sadikot</surname> <given-names>A. F.</given-names></name></person-group> (<year>2000</year>). <article-title>Evidence that ventrolateral thalamotomy may eliminate the supraspinal component of both pathological and physiological tremors.</article-title> <source><italic>Exp. Brain Res.</italic></source> <volume>132</volume> <fpage>216</fpage>&#x2013;<lpage>222</lpage>. <pub-id pub-id-type="doi">10.1007/s002210000358</pub-id> <pub-id pub-id-type="pmid">10853946</pub-id></citation></ref>
<ref id="B18"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Elble</surname> <given-names>R.</given-names></name> <name><surname>Bain</surname> <given-names>P.</given-names></name> <name><surname>Jo&#x00E3;o Forjaz</surname> <given-names>M.</given-names></name> <name><surname>Haubenberger</surname> <given-names>D.</given-names></name> <name><surname>Testa</surname> <given-names>C.</given-names></name> <name><surname>Goetz</surname> <given-names>C. G.</given-names></name><etal/></person-group> (<year>2013</year>). <article-title>Task force report: scales for screening and evaluating tremor: critique and recommendations.</article-title> <source><italic>Mov. Disord.</italic></source> <volume>28</volume> <fpage>1793</fpage>&#x2013;<lpage>1800</lpage>. <pub-id pub-id-type="doi">10.1002/mds.25648</pub-id> <pub-id pub-id-type="pmid">24038576</pub-id></citation></ref>
<ref id="B19"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Elble</surname> <given-names>R.</given-names></name> <name><surname>Comella</surname> <given-names>C.</given-names></name> <name><surname>Fahn</surname> <given-names>S.</given-names></name> <name><surname>Hallett</surname> <given-names>M.</given-names></name> <name><surname>Jankovic</surname> <given-names>J.</given-names></name> <name><surname>Juncos</surname> <given-names>J. L.</given-names></name><etal/></person-group> (<year>2012</year>). <article-title>Reliability of a new scale for essential tremor.</article-title> <source><italic>Mov. Disord.</italic></source> <volume>27</volume> <fpage>1567</fpage>&#x2013;<lpage>1569</lpage>. <pub-id pub-id-type="doi">10.1002/mds.25162</pub-id> <pub-id pub-id-type="pmid">23032792</pub-id></citation></ref>
<ref id="B20"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Elble</surname> <given-names>R. J.</given-names></name></person-group> (<year>2000</year>). <article-title>Essential tremor frequency decreases with time.</article-title> <source><italic>Neurology</italic></source> <volume>55</volume> <fpage>1547</fpage>&#x2013;<lpage>1551</lpage>. <pub-id pub-id-type="doi">10.1212/WNL.55.10.1547</pub-id> <pub-id pub-id-type="pmid">11094112</pub-id></citation></ref>
<ref id="B21"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Elble</surname> <given-names>R. J.</given-names></name></person-group> (<year>2018</year>). <article-title>Estimating change in tremor amplitude using clinical ratings: recommendations for clinical trials.</article-title> <source><italic>Tremor Other Hyperkinet. Mov.</italic></source> <volume>8</volume>:<fpage>600</fpage>. <pub-id pub-id-type="doi">10.5334/tohm.455</pub-id> <pub-id pub-id-type="pmid">31637097</pub-id></citation></ref>
<ref id="B22"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Elble</surname> <given-names>R. J.</given-names></name></person-group> (<year>2020</year>). <article-title>Do we belittle essential tremor by calling it a syndrome rather than a disease? No.</article-title> <source><italic>Front. Neurol.</italic></source> <volume>11</volume>:<fpage>586606</fpage>. <pub-id pub-id-type="doi">10.3389/fneur.2020.522687</pub-id> <pub-id pub-id-type="pmid">33178097</pub-id></citation></ref>
<ref id="B23"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Elble</surname> <given-names>R. J.</given-names></name> <name><surname>Hellriegel</surname> <given-names>H.</given-names></name> <name><surname>Raethjen</surname> <given-names>J.</given-names></name> <name><surname>Deuschl</surname> <given-names>G.</given-names></name></person-group> (<year>2017</year>). <article-title>Assessment of head tremor with accelerometers versus gyroscopic transducers.</article-title> <source><italic>Mov. Disord. Clin. Pract.</italic></source> <volume>4</volume> <fpage>205</fpage>&#x2013;<lpage>211</lpage>. <pub-id pub-id-type="doi">10.1002/mdc3.12379</pub-id> <pub-id pub-id-type="pmid">30363428</pub-id></citation></ref>
<ref id="B24"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Elble</surname> <given-names>R. J.</given-names></name> <name><surname>McNames</surname> <given-names>J.</given-names></name></person-group> (<year>2016</year>). <article-title>Using portable transducers to measure tremor severity.</article-title> <source><italic>Tremor Other Hyperkinet. Mov.</italic></source> <volume>6</volume>:<fpage>375</fpage>. <pub-id pub-id-type="doi">10.5334/tohm.320</pub-id> <pub-id pub-id-type="pmid">27257514</pub-id></citation></ref>
<ref id="B25"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Elble</surname> <given-names>R. J.</given-names></name> <name><surname>Pullman</surname> <given-names>S. L.</given-names></name> <name><surname>Matsumoto</surname> <given-names>J. Y.</given-names></name> <name><surname>Raethjen</surname> <given-names>J.</given-names></name> <name><surname>Deuschl</surname> <given-names>G.</given-names></name> <name><surname>Tintner</surname> <given-names>R.</given-names></name></person-group> (<year>2006</year>). <article-title>Tremor amplitude is logarithmically related to 4- and 5-point tremor rating scales.</article-title> <source><italic>Brain</italic></source> <volume>129</volume> <fpage>2660</fpage>&#x2013;<lpage>2666</lpage>. <pub-id pub-id-type="doi">10.1093/brain/awl190</pub-id> <pub-id pub-id-type="pmid">16891320</pub-id></citation></ref>
<ref id="B26"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Elias</surname> <given-names>W. J.</given-names></name> <name><surname>Lipsman</surname> <given-names>N.</given-names></name> <name><surname>Ondo</surname> <given-names>W. G.</given-names></name> <name><surname>Ghanouni</surname> <given-names>P.</given-names></name> <name><surname>Kim</surname> <given-names>Y. G.</given-names></name> <name><surname>Lee</surname> <given-names>W.</given-names></name><etal/></person-group> (<year>2016</year>). <article-title>A randomized trial of focused ultrasound thalamotomy for essential tremor.</article-title> <source><italic>N. Engl. J. Med.</italic></source> <volume>375</volume> <fpage>730</fpage>&#x2013;<lpage>739</lpage>. <pub-id pub-id-type="doi">10.1056/NEJMoa1600159</pub-id> <pub-id pub-id-type="pmid">27557301</pub-id></citation></ref>
<ref id="B27"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Erro</surname> <given-names>R.</given-names></name> <name><surname>Fasano</surname> <given-names>A.</given-names></name> <name><surname>Barone</surname> <given-names>P.</given-names></name> <name><surname>Bhatia</surname> <given-names>K. P.</given-names></name></person-group> (<year>2022</year>). <article-title>Milestones in tremor research: 10 years later.</article-title> <source><italic>Mov. Disord. Clin. Pract.</italic></source> <volume>9</volume> <fpage>429</fpage>&#x2013;<lpage>435</lpage>. <pub-id pub-id-type="doi">10.1002/mdc3.13418</pub-id> <pub-id pub-id-type="pmid">35582314</pub-id></citation></ref>
<ref id="B28"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fahn</surname> <given-names>S.</given-names></name> <name><surname>Tolosa</surname> <given-names>E.</given-names></name> <name><surname>Marin</surname> <given-names>C.</given-names></name> <name><surname>Jankovic</surname> <given-names>J.</given-names></name></person-group> (<year>1993</year>). &#x201C;<article-title>Parkinson&#x2019;s disease and movement disorders</article-title>,&#x201D; in <source><italic>Clinical Rating Scale for Tremor</italic></source>, <edition>2nd Edn</edition>, <role>eds</role> <person-group person-group-type="editor"><name><surname>Jankovic</surname> <given-names>J.</given-names></name> <name><surname>Tolosa</surname> <given-names>E.</given-names></name></person-group> (<publisher-loc>New York, NY</publisher-loc>: <publisher-name>Williams &#x0026; Wilkins</publisher-name>), <fpage>271</fpage>&#x2013;<lpage>280</lpage>.</citation></ref>
<ref id="B29"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fearon</surname> <given-names>C.</given-names></name> <name><surname>Espay</surname> <given-names>A. J.</given-names></name> <name><surname>Lang</surname> <given-names>A. E.</given-names></name> <name><surname>Lynch</surname> <given-names>T.</given-names></name> <name><surname>Martino</surname> <given-names>D.</given-names></name> <name><surname>Morgante</surname> <given-names>F.</given-names></name><etal/></person-group> (<year>2019</year>). <article-title>Soft signs in movement disorders: friends or foes?</article-title> <source><italic>J. Neurol. Neurosurg. Psychiatry</italic></source> <volume>90</volume> <fpage>961</fpage>&#x2013;<lpage>962</lpage>. <pub-id pub-id-type="doi">10.1136/jnnp-2018-318455</pub-id> <pub-id pub-id-type="pmid">30409889</pub-id></citation></ref>
<ref id="B30"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ferreira</surname> <given-names>J. J.</given-names></name> <name><surname>Mestre</surname> <given-names>T. A.</given-names></name> <name><surname>Lyons</surname> <given-names>K. E.</given-names></name> <name><surname>Benito-Le&#x00F3;n</surname> <given-names>J.</given-names></name> <name><surname>Tan</surname> <given-names>E. K.</given-names></name> <name><surname>Abbruzzese</surname> <given-names>G.</given-names></name><etal/></person-group> (<year>2019</year>). <article-title>MDS evidence-based review of treatments for essential tremor.</article-title> <source><italic>Mov. Disord.</italic></source> <volume>34</volume> <fpage>950</fpage>&#x2013;<lpage>958</lpage>. <pub-id pub-id-type="doi">10.1002/mds.27700</pub-id> <pub-id pub-id-type="pmid">31046186</pub-id></citation></ref>
<ref id="B31"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fitzgerald</surname> <given-names>J. J.</given-names></name> <name><surname>Lu</surname> <given-names>Z.</given-names></name> <name><surname>Jareonsettasin</surname> <given-names>P.</given-names></name> <name><surname>Antoniades</surname> <given-names>C. A.</given-names></name></person-group> (<year>2018</year>). <article-title>Quantifying motor impairment in movement disorders.</article-title> <source><italic>Front. Neurosci.</italic></source> <volume>12</volume>:<fpage>202</fpage>. <pub-id pub-id-type="doi">10.3389/fnins.2018.00202</pub-id> <pub-id pub-id-type="pmid">29695949</pub-id></citation></ref>
<ref id="B32"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Geiger</surname> <given-names>D. W.</given-names></name> <name><surname>Eggett</surname> <given-names>D. L.</given-names></name> <name><surname>Charles</surname> <given-names>S. K.</given-names></name></person-group> (<year>2018</year>). <article-title>A method for characterizing essential tremor from the shoulder to the wrist.</article-title> <source><italic>Clin. Biomech.</italic></source> <volume>52</volume> <fpage>117</fpage>&#x2013;<lpage>123</lpage>. <pub-id pub-id-type="doi">10.1016/j.clinbiomech.2017.12.003</pub-id> <pub-id pub-id-type="pmid">29428341</pub-id></citation></ref>
<ref id="B33"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gionco</surname> <given-names>J. T.</given-names></name> <name><surname>Hartstone</surname> <given-names>W. G.</given-names></name> <name><surname>Martuscello</surname> <given-names>R. T.</given-names></name> <name><surname>Kuo</surname> <given-names>S. H.</given-names></name> <name><surname>Faust</surname> <given-names>P. L.</given-names></name> <name><surname>Louis</surname> <given-names>E. D.</given-names></name></person-group> (<year>2021</year>). <article-title>Essential tremor versus &#x201C;ET-Plus&#x201D;: a detailed postmortem study of cerebellar pathology.</article-title> <source><italic>Cerebellum</italic></source> <volume>20</volume> <fpage>904</fpage>&#x2013;<lpage>912</lpage>. <pub-id pub-id-type="doi">10.1007/s12311-021-01263-6</pub-id> <pub-id pub-id-type="pmid">33768479</pub-id></citation></ref>
<ref id="B34"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Grimaldi</surname> <given-names>G.</given-names></name> <name><surname>Manto</surname> <given-names>M.</given-names></name></person-group> (<year>2010</year>). <article-title>Neurological tremor: sensors, signal processing and emerging applications.</article-title> <source><italic>Sensors</italic></source> <volume>10</volume> <fpage>1399</fpage>&#x2013;<lpage>1422</lpage>. <pub-id pub-id-type="doi">10.3390/s100201399</pub-id> <pub-id pub-id-type="pmid">22205874</pub-id></citation></ref>
<ref id="B35"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Grimaldi</surname> <given-names>G.</given-names></name> <name><surname>Manto</surname> <given-names>M.</given-names></name></person-group> (<year>2013</year>). <source><italic>Mechanisms and Emerging Therapies in Tremor Disorders.</italic></source> <publisher-loc>New York, NY</publisher-loc>: <publisher-name>Springer</publisher-name>. <pub-id pub-id-type="doi">10.1007/978-1-4614-4027-7</pub-id></citation></ref>
<ref id="B36"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hallett</surname> <given-names>M.</given-names></name></person-group> (<year>2016</year>). <article-title>Neurophysiologic studies of functional neurologic disorders.</article-title> <source><italic>Handb. Clin. Neurol.</italic></source> <volume>139</volume> <fpage>61</fpage>&#x2013;<lpage>71</lpage>. <pub-id pub-id-type="doi">10.1016/B978-0-12-801772-2.00006-0</pub-id> <pub-id pub-id-type="pmid">27719876</pub-id></citation></ref>
<ref id="B37"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Haubenberger</surname> <given-names>D.</given-names></name> <name><surname>Abbruzzese</surname> <given-names>G.</given-names></name> <name><surname>Bain</surname> <given-names>P. G.</given-names></name> <name><surname>Bajaj</surname> <given-names>N.</given-names></name> <name><surname>Benito-Leon</surname> <given-names>J.</given-names></name> <name><surname>Bhatia</surname> <given-names>K. P.</given-names></name><etal/></person-group> (<year>2016</year>). <article-title>Transducer-based evaluation of tremor.</article-title> <source><italic>Mov. Disord.</italic></source> <volume>31</volume> <fpage>1327</fpage>&#x2013;<lpage>1336</lpage>. <pub-id pub-id-type="doi">10.1002/mds.26671</pub-id> <pub-id pub-id-type="pmid">27273470</pub-id></citation></ref>
<ref id="B38"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hellwig</surname> <given-names>B.</given-names></name> <name><surname>Mund</surname> <given-names>P.</given-names></name> <name><surname>Schelter</surname> <given-names>B.</given-names></name> <name><surname>Guschlbauer</surname> <given-names>B.</given-names></name> <name><surname>Timmer</surname> <given-names>J.</given-names></name> <name><surname>Lucking</surname> <given-names>C. H.</given-names></name></person-group> (<year>2009</year>). <article-title>A longitudinal study of tremor frequencies in Parkinson&#x2019;s disease and essential tremor.</article-title> <source><italic>Clin. Neurophysiol.</italic></source> <volume>120</volume> <fpage>431</fpage>&#x2013;<lpage>435</lpage>. <pub-id pub-id-type="doi">10.1016/j.clinph.2008.11.002</pub-id> <pub-id pub-id-type="pmid">19101200</pub-id></citation></ref>
<ref id="B39"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hossen</surname> <given-names>A.</given-names></name> <name><surname>Muthuraman</surname> <given-names>M.</given-names></name> <name><surname>Al-Hakim</surname> <given-names>Z.</given-names></name> <name><surname>Raethjen</surname> <given-names>J.</given-names></name> <name><surname>Deuschl</surname> <given-names>G.</given-names></name> <name><surname>Heute</surname> <given-names>U.</given-names></name></person-group> (<year>2013</year>). <article-title>Discrimination of Parkinsonian tremor from essential tremor using statistical signal characterization of the spectrum of accelerometer signal.</article-title> <source><italic>Biomed. Mater. Eng.</italic></source> <volume>23</volume> <fpage>513</fpage>&#x2013;<lpage>531</lpage>. <pub-id pub-id-type="doi">10.3233/BME-130773</pub-id> <pub-id pub-id-type="pmid">24165554</pub-id></citation></ref>
<ref id="B40"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Iglesias-Hernandez</surname> <given-names>D.</given-names></name> <name><surname>Delgado</surname> <given-names>N.</given-names></name> <name><surname>Mcgurn</surname> <given-names>M.</given-names></name> <name><surname>Huey</surname> <given-names>E. D.</given-names></name> <name><surname>Cosentino</surname> <given-names>S.</given-names></name> <name><surname>Louis</surname> <given-names>E. D.</given-names></name></person-group> (<year>2021</year>). <article-title>&#x201C;ET Plus&#x201D;: instability of the diagnosis during prospective longitudinal follow-up of essential tremor cases.</article-title> <source><italic>Front. Neurol.</italic></source> <volume>12</volume>:<fpage>782694</fpage>. <pub-id pub-id-type="doi">10.3389/fneur.2021.782694</pub-id> <pub-id pub-id-type="pmid">34975736</pub-id></citation></ref>
<ref id="B41"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jeon</surname> <given-names>H.</given-names></name> <name><surname>Lee</surname> <given-names>W.</given-names></name> <name><surname>Park</surname> <given-names>H.</given-names></name> <name><surname>Lee</surname> <given-names>H. J.</given-names></name> <name><surname>Kim</surname> <given-names>S. K.</given-names></name> <name><surname>Kim</surname> <given-names>H. B.</given-names></name><etal/></person-group> (<year>2017</year>). <article-title>Automatic classification of tremor severity in parkinson&#x2019;s disease using a wearable device.</article-title> <source><italic>Sensors</italic></source> <volume>17</volume>:<fpage>2067</fpage>. <pub-id pub-id-type="doi">10.3390/s17092067</pub-id> <pub-id pub-id-type="pmid">28891942</pub-id></citation></ref>
<ref id="B42"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jones</surname> <given-names>E. G.</given-names></name></person-group> (<year>2007</year>). <source><italic>The Thalamus.</italic></source> <publisher-loc>Cambridge, MA</publisher-loc>: <publisher-name>Cambridge University Press</publisher-name>.</citation></ref>
<ref id="B43"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lee</surname> <given-names>H. J.</given-names></name> <name><surname>Kim</surname> <given-names>S. K.</given-names></name> <name><surname>Park</surname> <given-names>H.</given-names></name> <name><surname>Kim</surname> <given-names>H. B.</given-names></name> <name><surname>Jeon</surname> <given-names>H. S.</given-names></name> <name><surname>Jung</surname> <given-names>Y. J.</given-names></name><etal/></person-group> (<year>2015</year>). <article-title>Clinicians&#x2019; tendencies to under-rate parkinsonian tremors in the less affected hand.</article-title> <source><italic>PLoS One</italic></source> <volume>10</volume>:<fpage>e0131703</fpage>. <pub-id pub-id-type="doi">10.1371/journal.pone.0131703</pub-id> <pub-id pub-id-type="pmid">26110768</pub-id></citation></ref>
<ref id="B44"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lopez-Blanco</surname> <given-names>R.</given-names></name> <name><surname>Velasco</surname> <given-names>M. A.</given-names></name> <name><surname>Mendez-Guerrero</surname> <given-names>A.</given-names></name> <name><surname>Romero</surname> <given-names>J. P.</given-names></name> <name><surname>del Castillo</surname> <given-names>M. D.</given-names></name> <name><surname>Serrano</surname> <given-names>J. I.</given-names></name><etal/></person-group> (<year>2018</year>). <article-title>Essential tremor quantification based on the combined use of a smartphone and a smartwatch: the NetMD study.</article-title> <source><italic>J. Neurosci. Methods</italic></source> <volume>303</volume> <fpage>95</fpage>&#x2013;<lpage>102</lpage>. <pub-id pub-id-type="doi">10.1016/j.jneumeth.2018.02.015</pub-id> <pub-id pub-id-type="pmid">29481820</pub-id></citation></ref>
<ref id="B45"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>L&#x00F3;pez-Blanco</surname> <given-names>R.</given-names></name> <name><surname>Velasco</surname> <given-names>M. A.</given-names></name> <name><surname>M&#x00E9;ndez-Guerrero</surname> <given-names>A.</given-names></name> <name><surname>Romero</surname> <given-names>J. P.</given-names></name> <name><surname>del Castillo</surname> <given-names>M. D.</given-names></name> <name><surname>Serrano</surname> <given-names>J. I.</given-names></name><etal/></person-group> (<year>2019</year>). <article-title>Smartwatch for the analysis of rest tremor in patients with Parkinson&#x2019;s disease.</article-title> <source><italic>J. Neurol. Sci.</italic></source> <volume>401</volume> <fpage>37</fpage>&#x2013;<lpage>42</lpage>. <pub-id pub-id-type="doi">10.1016/j.jns.2019.04.011</pub-id> <pub-id pub-id-type="pmid">31005763</pub-id></citation></ref>
<ref id="B46"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Louis</surname> <given-names>E. D.</given-names></name></person-group> (<year>2013</year>). <article-title>The primary type of tremor in essential tremor is kinetic rather than postural: cross-sectional observation of tremor phenomenology in 369 cases.</article-title> <source><italic>Eur. J. Neurol.</italic></source> <volume>20</volume> <fpage>725</fpage>&#x2013;<lpage>727</lpage>. <pub-id pub-id-type="doi">10.1111/j.1468-1331.2012.03855.x</pub-id> <pub-id pub-id-type="pmid">22925197</pub-id></citation></ref>
<ref id="B47"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Louis</surname> <given-names>E. D.</given-names></name> <name><surname>Bares</surname> <given-names>M.</given-names></name> <name><surname>Benito-Leon</surname> <given-names>J.</given-names></name> <name><surname>Fahn</surname> <given-names>S.</given-names></name> <name><surname>Frucht</surname> <given-names>S. J.</given-names></name> <name><surname>Jankovic</surname> <given-names>J.</given-names></name><etal/></person-group> (<year>2020</year>). <article-title>Essential tremor-plus: a controversial new concept.</article-title> <source><italic>Lancet Neurol.</italic></source> <volume>19</volume> <fpage>266</fpage>&#x2013;<lpage>270</lpage>. <pub-id pub-id-type="doi">10.1016/S1474-4422(19)30398-9</pub-id> <pub-id pub-id-type="pmid">31767343</pub-id></citation></ref>
<ref id="B48"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Louis</surname> <given-names>E. D.</given-names></name> <name><surname>Faust</surname> <given-names>P. L.</given-names></name></person-group> (<year>2020</year>). <article-title>Essential tremor pathology: neurodegeneration and reorganization of neuronal connections.</article-title> <source><italic>Nat. Rev. Neurol.</italic></source> <volume>16</volume> <fpage>69</fpage>&#x2013;<lpage>83</lpage>. <pub-id pub-id-type="doi">10.1038/s41582-019-0302-1</pub-id> <pub-id pub-id-type="pmid">31959938</pub-id></citation></ref>
<ref id="B49"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Luft</surname> <given-names>F.</given-names></name> <name><surname>Sharifi</surname> <given-names>S.</given-names></name> <name><surname>Mugge</surname> <given-names>W.</given-names></name> <name><surname>Schouten</surname> <given-names>A. C.</given-names></name> <name><surname>Bour</surname> <given-names>L. J.</given-names></name> <name><surname>van Rootselaar</surname> <given-names>A. F.</given-names></name><etal/></person-group> (<year>2019</year>). <article-title>A power spectral density-based method to detect tremor and tremor intermittency in movement disorders.</article-title> <source><italic>Sensors</italic></source> <volume>19</volume>:<fpage>4301</fpage>. <pub-id pub-id-type="doi">10.3390/s19194301</pub-id> <pub-id pub-id-type="pmid">31590227</pub-id></citation></ref>
<ref id="B50"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Milton</surname> <given-names>J.</given-names></name> <name><surname>Ohira</surname> <given-names>T.</given-names></name></person-group> (<year>2021</year>). <source><italic>Mathematics as a Laboratory Tool: Dynamics, Delays and Noise.</italic></source> <publisher-loc>New York, NY</publisher-loc>: <publisher-name>Springer</publisher-name>. <pub-id pub-id-type="doi">10.1007/978-3-030-69579-8</pub-id></citation></ref>
<ref id="B51"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mostile</surname> <given-names>G.</given-names></name> <name><surname>Fekete</surname> <given-names>R.</given-names></name> <name><surname>Giuffrida</surname> <given-names>J. P.</given-names></name> <name><surname>Yaltho</surname> <given-names>T.</given-names></name> <name><surname>Davidson</surname> <given-names>A.</given-names></name> <name><surname>Nicoletti</surname> <given-names>A.</given-names></name><etal/></person-group> (<year>2012</year>). <article-title>Amplitude fluctuations in essential tremor.</article-title> <source><italic>Parkinson. Relat. Disord.</italic></source> <volume>18</volume> <fpage>859</fpage>&#x2013;<lpage>863</lpage>. <pub-id pub-id-type="doi">10.1016/j.parkreldis.2012.04.019</pub-id> <pub-id pub-id-type="pmid">22591578</pub-id></citation></ref>
<ref id="B52"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Nistico</surname> <given-names>R.</given-names></name> <name><surname>Fratto</surname> <given-names>A.</given-names></name> <name><surname>Vescio</surname> <given-names>B.</given-names></name> <name><surname>Arabia</surname> <given-names>G.</given-names></name> <name><surname>Sciacca</surname> <given-names>G.</given-names></name> <name><surname>Morelli</surname> <given-names>M.</given-names></name><etal/></person-group> (<year>2016</year>). <article-title>Tremor pattern differentiates drug-induced resting tremor from Parkinson disease.</article-title> <source><italic>Parkinson. Relat. Disord.</italic></source> <volume>25</volume> <fpage>100</fpage>&#x2013;<lpage>103</lpage>. <pub-id pub-id-type="doi">10.1016/j.parkreldis.2016.02.002</pub-id> <pub-id pub-id-type="pmid">26895708</pub-id></citation></ref>
<ref id="B53"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ondo</surname> <given-names>W.</given-names></name> <name><surname>Hashem</surname> <given-names>V.</given-names></name> <name><surname>Lewitt</surname> <given-names>P. A.</given-names></name> <name><surname>Pahwa</surname> <given-names>R.</given-names></name> <name><surname>Shih</surname> <given-names>L.</given-names></name> <name><surname>Tarsy</surname> <given-names>D.</given-names></name><etal/></person-group> (<year>2018</year>). <article-title>Comparison of the fahn-tolosa-marin clinical rating scale and the essential tremor rating assessment scale.</article-title> <source><italic>Mov. Disord. Clin. Pract.</italic></source> <volume>5</volume> <fpage>60</fpage>&#x2013;<lpage>65</lpage>. <pub-id pub-id-type="doi">10.1002/mdc3.12560</pub-id> <pub-id pub-id-type="pmid">30363460</pub-id></citation></ref>
<ref id="B54"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ondo</surname> <given-names>W. G.</given-names></name> <name><surname>Pascual</surname> <given-names>B.</given-names></name></person-group> <collab>Tremor Research Group</collab> (<year>2020</year>). <article-title>Tremor research group essential tremor rating scale (TETRAS): assessing impact of different item instructions and procedures.</article-title> <source><italic>Tremor Other Hyperkinet. Mov.</italic></source> <volume>10</volume>:<fpage>36</fpage>. <pub-id pub-id-type="doi">10.5334/tohm.64</pub-id> <pub-id pub-id-type="pmid">33101762</pub-id></citation></ref>
<ref id="B55"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pan</surname> <given-names>D.</given-names></name> <name><surname>Dhall</surname> <given-names>R.</given-names></name> <name><surname>Lieberman</surname> <given-names>A.</given-names></name> <name><surname>Petitti</surname> <given-names>D. B.</given-names></name></person-group> (<year>2015</year>). <article-title>A mobile cloud-based Parkinson&#x2019;s disease assessment system for home-based monitoring.</article-title> <source><italic>JMIR Mhealth Uhealth</italic></source> <volume>3</volume>:<fpage>e29</fpage>. <pub-id pub-id-type="doi">10.2196/mhealth.3956</pub-id> <pub-id pub-id-type="pmid">25830687</pub-id></citation></ref>
<ref id="B56"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pan</surname> <given-names>M. K.</given-names></name> <name><surname>Kuo</surname> <given-names>S. H.</given-names></name></person-group> (<year>2022</year>). <article-title>Essential tremor: clinical perspectives and pathophysiology.</article-title> <source><italic>J. Neurol. Sci.</italic></source> <volume>435</volume>:<fpage>120198</fpage>. <pub-id pub-id-type="doi">10.1016/j.jns.2022.120198</pub-id> <pub-id pub-id-type="pmid">35299120</pub-id></citation></ref>
<ref id="B57"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pandey</surname> <given-names>S.</given-names></name> <name><surname>Bhattad</surname> <given-names>S.</given-names></name> <name><surname>Hallett</surname> <given-names>M.</given-names></name></person-group> (<year>2020</year>). <article-title>The problem of questionable dystonia in the diagnosis of &#x2018;essential tremor-plus&#x2019;.</article-title> <source><italic>Tremor Other Hyperkinet. Mov.</italic></source> <volume>10</volume>:<fpage>27</fpage>. <pub-id pub-id-type="doi">10.5334/tohm.539</pub-id> <pub-id pub-id-type="pmid">32864186</pub-id></citation></ref>
<ref id="B58"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Paris-Robidas</surname> <given-names>S.</given-names></name> <name><surname>Brochu</surname> <given-names>E.</given-names></name> <name><surname>Sintes</surname> <given-names>M.</given-names></name> <name><surname>Emond</surname> <given-names>V.</given-names></name> <name><surname>Bousquet</surname> <given-names>M.</given-names></name> <name><surname>Vandal</surname> <given-names>M.</given-names></name><etal/></person-group> (<year>2012</year>). <article-title>Defective dentate nucleus GABA receptors in essential tremor.</article-title> <source><italic>Brain</italic></source> <volume>135</volume> <fpage>105</fpage>&#x2013;<lpage>116</lpage>. <pub-id pub-id-type="doi">10.1093/brain/awr301</pub-id> <pub-id pub-id-type="pmid">22120148</pub-id></citation></ref>
<ref id="B59"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pavey</surname> <given-names>T. G.</given-names></name> <name><surname>Gomersall</surname> <given-names>S. R.</given-names></name> <name><surname>Clark</surname> <given-names>B. K.</given-names></name> <name><surname>Brown</surname> <given-names>W. J.</given-names></name></person-group> (<year>2016</year>). <article-title>The validity of the GENEActiv wrist-worn accelerometer for measuring adult sedentary time in free living.</article-title> <source><italic>J. Sci. Med. Sport</italic></source> <volume>19</volume> <fpage>395</fpage>&#x2013;<lpage>399</lpage>. <pub-id pub-id-type="doi">10.1016/j.jsams.2015.04.007</pub-id> <pub-id pub-id-type="pmid">25956687</pub-id></citation></ref>
<ref id="B60"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pulliam</surname> <given-names>C. L.</given-names></name> <name><surname>Eichenseer</surname> <given-names>S. R.</given-names></name> <name><surname>Goetz</surname> <given-names>C. G.</given-names></name> <name><surname>Waln</surname> <given-names>O.</given-names></name> <name><surname>Hunter</surname> <given-names>C. B.</given-names></name> <name><surname>Jankovic</surname> <given-names>J.</given-names></name><etal/></person-group> (<year>2014</year>). <article-title>Continuous in-home monitoring of essential tremor.</article-title> <source><italic>Parkinson. Relat. Disord.</italic></source> <volume>20</volume> <fpage>37</fpage>&#x2013;<lpage>40</lpage>. <pub-id pub-id-type="doi">10.1016/j.parkreldis.2013.09.009</pub-id> <pub-id pub-id-type="pmid">24126021</pub-id></citation></ref>
<ref id="B61"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pulliam</surname> <given-names>C. L.</given-names></name> <name><surname>Heldman</surname> <given-names>D. A.</given-names></name> <name><surname>Brokaw</surname> <given-names>E. B.</given-names></name> <name><surname>Mera</surname> <given-names>T. O.</given-names></name> <name><surname>Mari</surname> <given-names>Z. K.</given-names></name> <name><surname>Burack</surname> <given-names>M. A.</given-names></name></person-group> (<year>2018</year>). <article-title>Continuous assessment of levodopa response in Parkinson&#x2019;s disease using wearable motion sensors.</article-title> <source><italic>IEEE Trans. Biomed. Eng.</italic></source> <volume>65</volume> <fpage>159</fpage>&#x2013;<lpage>164</lpage>. <pub-id pub-id-type="doi">10.1109/TBME.2017.2697764</pub-id> <pub-id pub-id-type="pmid">28459677</pub-id></citation></ref>
<ref id="B62"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Raethjen</surname> <given-names>J.</given-names></name> <name><surname>Deuschl</surname> <given-names>G.</given-names></name></person-group> (<year>2012</year>). <article-title>The oscillating central network of essential tremor.</article-title> <source><italic>Clin. Neurophysiol.</italic></source> <volume>123</volume> <fpage>61</fpage>&#x2013;<lpage>64</lpage>. <pub-id pub-id-type="doi">10.1016/j.clinph.2011.09.024</pub-id> <pub-id pub-id-type="pmid">22055842</pub-id></citation></ref>
<ref id="B63"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Rajput</surname> <given-names>A. H.</given-names></name> <name><surname>Rajput</surname> <given-names>E. F.</given-names></name> <name><surname>Bocking</surname> <given-names>S. M.</given-names></name> <name><surname>Auer</surname> <given-names>R. N.</given-names></name> <name><surname>Rajput</surname> <given-names>A.</given-names></name></person-group> (<year>2019</year>). <article-title>Parkinsonism in essential tremor cases: a clinicopathological study.</article-title> <source><italic>Mov. Disord.</italic></source> <volume>34</volume> <fpage>1031</fpage>&#x2013;<lpage>1040</lpage>. <pub-id pub-id-type="doi">10.1002/mds.27729</pub-id> <pub-id pub-id-type="pmid">31180613</pub-id></citation></ref>
<ref id="B64"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Salarian</surname> <given-names>A.</given-names></name> <name><surname>Russmann</surname> <given-names>H.</given-names></name> <name><surname>Wider</surname> <given-names>C.</given-names></name> <name><surname>Burkhard</surname> <given-names>P. R.</given-names></name> <name><surname>Vingerhoets</surname> <given-names>F. J.</given-names></name> <name><surname>Aminian</surname> <given-names>K.</given-names></name></person-group> (<year>2007</year>). <article-title>Quantification of tremor and bradykinesia in Parkinson&#x2019;s disease using a novel ambulatory monitoring system.</article-title> <source><italic>IEEE Trans. Biomed. Eng.</italic></source> <volume>54</volume> <fpage>313</fpage>&#x2013;<lpage>322</lpage>. <pub-id pub-id-type="doi">10.1109/TBME.2006.886670</pub-id> <pub-id pub-id-type="pmid">17278588</pub-id></citation></ref>
<ref id="B65"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sanders</surname> <given-names>S. G.</given-names></name> <name><surname>Jimenez</surname> <given-names>E. Y.</given-names></name> <name><surname>Cole</surname> <given-names>N. H.</given-names></name> <name><surname>Kuhlemeier</surname> <given-names>A.</given-names></name> <name><surname>Mccauley</surname> <given-names>G. L.</given-names></name> <name><surname>van Horn</surname> <given-names>M. L.</given-names></name><etal/></person-group> (<year>2019</year>). <article-title>Estimated physical activity in adolescents by wrist-worn GENEActiv accelerometers.</article-title> <source><italic>J. Phys. Act Health</italic></source> <volume>16</volume> <fpage>792</fpage>&#x2013;<lpage>798</lpage>. <pub-id pub-id-type="doi">10.1123/jpah.2018-0344</pub-id> <pub-id pub-id-type="pmid">31310994</pub-id></citation></ref>
<ref id="B66"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Schaltenbrand</surname> <given-names>G.</given-names></name> <name><surname>Wahren</surname> <given-names>W.</given-names></name> <name><surname>Hassler</surname> <given-names>R. G.</given-names></name></person-group> (<year>1977</year>). &#x201C;<article-title>Architectonic organization of the thalamic nuclei</article-title>,&#x201D; in <source><italic>Atlas for Stereotaxy of the Human Brain</italic></source>, <edition>2 Edn</edition>, <role>ed.</role> <person-group person-group-type="editor"><name><surname>Wahren</surname> <given-names>G. S. A. W.</given-names></name></person-group> (<publisher-loc>Stuttgart</publisher-loc>: <publisher-name>Thieme</publisher-name>).</citation></ref>
<ref id="B67"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Schuhmayer</surname> <given-names>N.</given-names></name> <name><surname>Weber</surname> <given-names>C.</given-names></name> <name><surname>Kieler</surname> <given-names>M.</given-names></name> <name><surname>Voller</surname> <given-names>B.</given-names></name> <name><surname>Pirker</surname> <given-names>W.</given-names></name> <name><surname>Auff</surname> <given-names>E.</given-names></name><etal/></person-group> (<year>2017</year>). <article-title>Task-dependent variability of essential tremor.</article-title> <source><italic>Parkinson. Relat. Disord.</italic></source> <volume>41</volume> <fpage>79</fpage>&#x2013;<lpage>85</lpage>. <pub-id pub-id-type="doi">10.1016/j.parkreldis.2017.05.018</pub-id> <pub-id pub-id-type="pmid">28576604</pub-id></citation></ref>
<ref id="B68"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Shanker</surname> <given-names>V.</given-names></name></person-group> (<year>2019</year>). <article-title>Essential tremor: diagnosis and management.</article-title> <source><italic>BMJ</italic></source> <volume>366</volume>:<fpage>l4485</fpage>. <pub-id pub-id-type="doi">10.1136/bmj.l4485</pub-id> <pub-id pub-id-type="pmid">31383632</pub-id></citation></ref>
<ref id="B69"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sharma</surname> <given-names>S.</given-names></name> <name><surname>Pandey</surname> <given-names>S.</given-names></name></person-group> (<year>2020</year>). <article-title>Treatment of essential tremor: current status.</article-title> <source><italic>Postgrad. Med. J.</italic></source> <volume>96</volume> <fpage>84</fpage>&#x2013;<lpage>93</lpage>. <pub-id pub-id-type="doi">10.1136/postgradmedj-2019-136647</pub-id> <pub-id pub-id-type="pmid">31575730</pub-id></citation></ref>
<ref id="B70"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Stacy</surname> <given-names>M. A.</given-names></name> <name><surname>Elble</surname> <given-names>R. J.</given-names></name> <name><surname>Ondo</surname> <given-names>W. G.</given-names></name> <name><surname>Wu</surname> <given-names>S.-C.</given-names></name> <name><surname>Hulihan</surname> <given-names>J.</given-names></name></person-group> <collab>TRS Study Group</collab> (<year>2007</year>). <article-title>Assessment of interrater and intrarater reliability of the Fahn&#x2013;Tolosa&#x2013;Marin Tremor Rating Scale in essential tremor.</article-title> <source><italic>Mov. Disord.</italic></source> <volume>22</volume> <fpage>833</fpage>&#x2013;<lpage>838</lpage>. <pub-id pub-id-type="doi">10.1002/mds.21412</pub-id> <pub-id pub-id-type="pmid">17343274</pub-id></citation></ref>
<ref id="B71"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Su</surname> <given-names>J. H.</given-names></name> <name><surname>Choi</surname> <given-names>E. Y.</given-names></name> <name><surname>Tourdias</surname> <given-names>T.</given-names></name> <name><surname>Saranathan</surname> <given-names>M.</given-names></name> <name><surname>Halpern</surname> <given-names>C. H.</given-names></name> <name><surname>Henderson</surname> <given-names>J. M.</given-names></name><etal/></person-group> (<year>2020</year>). <article-title>Improved Vim targeting for focused ultrasound ablation treatment of essential tremor: a probabilistic and patient-specific approach.</article-title> <source><italic>Hum. Brain Mapp.</italic></source> <volume>41</volume> <fpage>4769</fpage>&#x2013;<lpage>4788</lpage>. <pub-id pub-id-type="doi">10.1002/hbm.25157</pub-id> <pub-id pub-id-type="pmid">32762005</pub-id></citation></ref>
<ref id="B72"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Symanski</surname> <given-names>C.</given-names></name> <name><surname>Shill</surname> <given-names>H. A.</given-names></name> <name><surname>Dugger</surname> <given-names>B.</given-names></name> <name><surname>Hentz</surname> <given-names>J. G.</given-names></name> <name><surname>Adler</surname> <given-names>C. H.</given-names></name> <name><surname>Jacobson</surname> <given-names>S. A.</given-names></name><etal/></person-group> (<year>2014</year>). <article-title>Essential tremor is not associated with cerebellar Purkinje cell loss.</article-title> <source><italic>Mov. Disord.</italic></source> <volume>29</volume> <fpage>496</fpage>&#x2013;<lpage>500</lpage>. <pub-id pub-id-type="doi">10.1002/mds.25845</pub-id> <pub-id pub-id-type="pmid">24532134</pub-id></citation></ref>
<ref id="B73"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tarakad</surname> <given-names>A.</given-names></name></person-group> (<year>2020</year>). <article-title>Clinical rating scales and quantitative assessments of movement disorders.</article-title> <source><italic>Neurol. Clin.</italic></source> <volume>38</volume> <fpage>231</fpage>&#x2013;<lpage>254</lpage>. <pub-id pub-id-type="doi">10.1016/j.ncl.2019.12.001</pub-id> <pub-id pub-id-type="pmid">32279708</pub-id></citation></ref>
<ref id="B74"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tarakad</surname> <given-names>A.</given-names></name> <name><surname>Jankovic</surname> <given-names>J.</given-names></name></person-group> (<year>2018</year>). <article-title>Essential tremor and Parkinson&#x2019;s disease: exploring the relationship.</article-title> <source><italic>Tremor Other Hyperkinet. Mov.</italic></source> <volume>8</volume>:<fpage>589</fpage>. <pub-id pub-id-type="doi">10.5334/tohm.441</pub-id></citation></ref>
<ref id="B75"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Thangavelu</surname> <given-names>K.</given-names></name> <name><surname>Talk</surname> <given-names>A. C.</given-names></name> <name><surname>Clark</surname> <given-names>G. I.</given-names></name> <name><surname>Dissanayaka</surname> <given-names>N. N. W.</given-names></name></person-group> (<year>2020</year>). <article-title>Psychosocial factors and perceived tremor disability in essential tremor.</article-title> <source><italic>Neurosci. Biobehav. Rev.</italic></source> <volume>108</volume> <fpage>246</fpage>&#x2013;<lpage>253</lpage>. <pub-id pub-id-type="doi">10.1016/j.neubiorev.2019.10.021</pub-id> <pub-id pub-id-type="pmid">31682885</pub-id></citation></ref>
<ref id="B76"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>van Brummelen</surname> <given-names>E. M. J.</given-names></name> <name><surname>Ziagkos</surname> <given-names>D.</given-names></name> <name><surname>de Boon</surname> <given-names>W. M. I.</given-names></name> <name><surname>Hart</surname> <given-names>E. P.</given-names></name> <name><surname>Doll</surname> <given-names>R. J.</given-names></name> <name><surname>Huttunen</surname> <given-names>T.</given-names></name><etal/></person-group> (<year>2020</year>). <article-title>Quantification of tremor using consumer product accelerometry is feasible in patients with essential tremor and Parkinson&#x2019;s disease: a comparative study.</article-title> <source><italic>J. Clin. Mov. Disord.</italic></source> <volume>7</volume>:<fpage>4</fpage>. <pub-id pub-id-type="doi">10.1186/s40734-020-00086-7</pub-id> <pub-id pub-id-type="pmid">32280482</pub-id></citation></ref>
<ref id="B77"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>van de Wardt</surname> <given-names>J.</given-names></name> <name><surname>van der Stouwe</surname> <given-names>A. M. M.</given-names></name> <name><surname>Dirkx</surname> <given-names>M.</given-names></name> <name><surname>Elting</surname> <given-names>J. W. J.</given-names></name> <name><surname>Post</surname> <given-names>B.</given-names></name> <name><surname>Tijssen</surname> <given-names>M. A.</given-names></name><etal/></person-group> (<year>2020</year>). <article-title>Systematic clinical approach for diagnosing upper limb tremor.</article-title> <source><italic>J. Neurol. Neurosurg. Psychiatry</italic></source> <volume>91</volume> <fpage>822</fpage>&#x2013;<lpage>830</lpage>. <pub-id pub-id-type="doi">10.1136/jnnp-2019-322676</pub-id> <pub-id pub-id-type="pmid">32457087</pub-id></citation></ref>
<ref id="B78"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Welton</surname> <given-names>T.</given-names></name> <name><surname>Cardoso</surname> <given-names>F.</given-names></name> <name><surname>Carr</surname> <given-names>J. A.</given-names></name> <name><surname>Chan</surname> <given-names>L. L.</given-names></name> <name><surname>Deuschl</surname> <given-names>G.</given-names></name> <name><surname>Jankovic</surname> <given-names>J.</given-names></name><etal/></person-group> (<year>2021</year>). <article-title>Essential tremor.</article-title> <source><italic>Nat. Rev. Dis. Primers</italic></source> <volume>7</volume>:<fpage>83</fpage>. <pub-id pub-id-type="doi">10.1038/s41572-021-00314-w</pub-id> <pub-id pub-id-type="pmid">34764294</pub-id></citation></ref>
<ref id="B79"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wile</surname> <given-names>D. J.</given-names></name> <name><surname>Ranawaya</surname> <given-names>R.</given-names></name> <name><surname>Kiss</surname> <given-names>Z. H.</given-names></name></person-group> (<year>2014</year>). <article-title>Smart watch accelerometry for analysis and diagnosis of tremor.</article-title> <source><italic>J. Neurosci. Methods</italic></source> <volume>230</volume> <fpage>1</fpage>&#x2013;<lpage>4</lpage>. <pub-id pub-id-type="doi">10.1016/j.jneumeth.2014.04.021</pub-id> <pub-id pub-id-type="pmid">24769376</pub-id></citation></ref>
<ref id="B80"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wu</surname> <given-names>Y. C.</given-names></name> <name><surname>Louis</surname> <given-names>E. D.</given-names></name> <name><surname>Gionco</surname> <given-names>J.</given-names></name> <name><surname>Pan</surname> <given-names>M. K.</given-names></name> <name><surname>Faust</surname> <given-names>P. L.</given-names></name> <name><surname>Kuo</surname> <given-names>S. H.</given-names></name></person-group> (<year>2021</year>). <article-title>Increased climbing fiber lateral crossings on purkinje cell dendrites in the cerebellar hemisphere in essential tremor.</article-title> <source><italic>Mov. Disord.</italic></source> <volume>36</volume> <fpage>1440</fpage>&#x2013;<lpage>1445</lpage>. <pub-id pub-id-type="doi">10.1002/mds.28502</pub-id> <pub-id pub-id-type="pmid">33497495</pub-id></citation></ref>
<ref id="B81"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhang</surname> <given-names>J.</given-names></name> <name><surname>Xing</surname> <given-names>Y.</given-names></name> <name><surname>Ma</surname> <given-names>X.</given-names></name> <name><surname>Feng</surname> <given-names>L.</given-names></name></person-group> (<year>2017</year>). <article-title>Differential diagnosis of parkinson disease, essential tremor, and enhanced physiological tremor with the tremor analysis of EMG.</article-title> <source><italic>Parkinsons Dis.</italic></source> <volume>2017</volume>:<fpage>1597907</fpage>. <pub-id pub-id-type="doi">10.1155/2017/1597907</pub-id> <pub-id pub-id-type="pmid">28884038</pub-id></citation></ref>
</ref-list>
</back>
</article>