<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<?covid-19-tdm?>
<article article-type="research-article" dtd-version="2.3" xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Nanotechnol.</journal-id>
<journal-title>Frontiers in Nanotechnology</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Nanotechnol.</abbrev-journal-title>
<issn pub-type="epub">2673-3013</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">1505751</article-id>
<article-id pub-id-type="doi">10.3389/fnano.2024.1505751</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Nanotechnology</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>MoS<sub>2</sub>-based biosensor for SARS-CoV-2 detection: a numerical approach</article-title>
<alt-title alt-title-type="left-running-head">Tene et al.</alt-title>
<alt-title alt-title-type="right-running-head">
<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3389/fnano.2024.1505751">10.3389/fnano.2024.1505751</ext-link>
</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Tene</surname>
<given-names>Talia</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/2377430/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/data-curation/"/>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/>
<role content-type="https://credit.niso.org/contributor-roles/funding-acquisition/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/project-administration/"/>
<role content-type="https://credit.niso.org/contributor-roles/resources/"/>
<role content-type="https://credit.niso.org/contributor-roles/software/"/>
<role content-type="https://credit.niso.org/contributor-roles/supervision/"/>
<role content-type="https://credit.niso.org/contributor-roles/validation/"/>
<role content-type="https://credit.niso.org/contributor-roles/visualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Tubon-Usca</surname>
<given-names>Gabriela</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/2906906/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/data-curation/"/>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/>
<role content-type="https://credit.niso.org/contributor-roles/funding-acquisition/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/project-administration/"/>
<role content-type="https://credit.niso.org/contributor-roles/resources/"/>
<role content-type="https://credit.niso.org/contributor-roles/software/"/>
<role content-type="https://credit.niso.org/contributor-roles/supervision/"/>
<role content-type="https://credit.niso.org/contributor-roles/validation/"/>
<role content-type="https://credit.niso.org/contributor-roles/visualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Gallegos</surname>
<given-names>Katherine Tixi</given-names>
</name>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/data-curation/"/>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/>
<role content-type="https://credit.niso.org/contributor-roles/funding-acquisition/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/project-administration/"/>
<role content-type="https://credit.niso.org/contributor-roles/resources/"/>
<role content-type="https://credit.niso.org/contributor-roles/software/"/>
<role content-type="https://credit.niso.org/contributor-roles/supervision/"/>
<role content-type="https://credit.niso.org/contributor-roles/validation/"/>
<role content-type="https://credit.niso.org/contributor-roles/visualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Mendoza Salazar</surname>
<given-names>Mar&#xed;a Jos&#xe9;</given-names>
</name>
<xref ref-type="aff" rid="aff4">
<sup>4</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/2296401/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/data-curation/"/>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/>
<role content-type="https://credit.niso.org/contributor-roles/funding-acquisition/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/project-administration/"/>
<role content-type="https://credit.niso.org/contributor-roles/resources/"/>
<role content-type="https://credit.niso.org/contributor-roles/software/"/>
<role content-type="https://credit.niso.org/contributor-roles/supervision/"/>
<role content-type="https://credit.niso.org/contributor-roles/validation/"/>
<role content-type="https://credit.niso.org/contributor-roles/visualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Vacacela Gomez</surname>
<given-names>Cristian</given-names>
</name>
<xref ref-type="aff" rid="aff5">
<sup>5</sup>
</xref>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
<uri xlink:href="https://loop.frontiersin.org/people/2266775/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/data-curation/"/>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/>
<role content-type="https://credit.niso.org/contributor-roles/funding-acquisition/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/project-administration/"/>
<role content-type="https://credit.niso.org/contributor-roles/resources/"/>
<role content-type="https://credit.niso.org/contributor-roles/software/"/>
<role content-type="https://credit.niso.org/contributor-roles/supervision/"/>
<role content-type="https://credit.niso.org/contributor-roles/validation/"/>
<role content-type="https://credit.niso.org/contributor-roles/visualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
</contrib-group>
<aff id="aff1">
<sup>1</sup>
<institution>Department of Chemistry</institution>, <institution>Universidad T&#xe9;cnica Particular de Loja</institution>, <addr-line>Loja</addr-line>, <country>Ecuador</country>
</aff>
<aff id="aff2">
<sup>2</sup>
<institution>Grupo de Investigaci&#xf3;n en Materiales Avanzados (GIMA)</institution>, <institution>Facultad de Ciencias</institution>, <institution>Escuela Superior Polit&#xe9;cnica de Chimborazo (ESPOCH)</institution>, <addr-line>Riobamba</addr-line>, <country>Ecuador</country>
</aff>
<aff id="aff3">
<sup>3</sup>
<institution>Carrera de Ingenier&#xed;a Qu&#xed;mica</institution>, <institution>Facultad de Ciencias</institution>, <institution>Escuela Superior Polit&#xe9;cnica de Chimborazo (ESPOCH)</institution>, <addr-line>Riobamba</addr-line>, <country>Ecuador</country>
</aff>
<aff id="aff4">
<sup>4</sup>
<institution>Facultad de Ciencias</institution>, <institution>Grupo de Investigaci&#xf3;n CIDED</institution>, <institution>Escuela Superior Polit&#xe9;cnica de Chimborazo (ESPOCH)</institution>, <addr-line>Riobamba</addr-line>, <country>Ecuador</country>
</aff>
<aff id="aff5">
<sup>5</sup>
<institution>INFN-Laboratori Nazionali di Frascati</institution>, <addr-line>Frascati</addr-line>, <country>Italy</country>
</aff>
<author-notes>
<fn fn-type="edited-by">
<p>
<bold>Edited by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/2816040/overview">Sujit Das</ext-link>, Indian Institute of Science (IISc), India</p>
</fn>
<fn fn-type="edited-by">
<p>
<bold>Reviewed by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/2862714/overview">Pravin Kavle</ext-link>, University of California, Berkeley, United States</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/2889960/overview">Megha Acharya</ext-link>, Applied Materials, United States</p>
</fn>
<corresp id="c001">&#x2a;Correspondence: Cristian Vacacela Gomez, <email>vacacela@lnf.infn.it</email>
</corresp>
</author-notes>
<pub-date pub-type="epub">
<day>07</day>
<month>01</month>
<year>2025</year>
</pub-date>
<pub-date pub-type="collection">
<year>2024</year>
</pub-date>
<volume>6</volume>
<elocation-id>1505751</elocation-id>
<history>
<date date-type="received">
<day>03</day>
<month>10</month>
<year>2024</year>
</date>
<date date-type="accepted">
<day>13</day>
<month>12</month>
<year>2024</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2025 Tene, Tubon-Usca, Gallegos, Mendoza Salazar and Vacacela Gomez.</copyright-statement>
<copyright-year>2025</copyright-year>
<copyright-holder>Tene, Tubon-Usca, Gallegos, Mendoza Salazar and Vacacela Gomez</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<p>Surface plasmon resonance (SPR) biosensors are powerful tools for highly sensitive and specific detection of biomolecules. This study introduces a MoS&#x2082;-based SPR biosensor optimized for SARS-CoV-2 detection. The sensor integrates a multilayer configuration, including a BK7 prism, Ag film (45&#xa0;nm), S&#x2083;N&#x2084; layer (13&#xa0;nm), MoS&#x2082; monolayer (0.65&#xa0;nm), and functionalized ssDNA layer (5&#xa0;nm). Systematic optimization of each layer improved plasmonic coupling, propagation, and specificity, achieving a balance between sensitivity, resolution, and efficiency. The optimized biosensor was evaluated across virus concentrations ranging from 0.01 to 150&#xa0;mM. The proposed biosensor demonstrated excellent performance at moderate to high concentrations, with sensitivity up to 261.33&#xb0;/RIU, a quality factor of 36.16 RIU<sup>&#x2212;1</sup>, and a limit of detection of 1.91 &#xd7; 10<sup>&#x2212;5</sup>. An optimal figure of merit of 405.50 RIU<sup>&#x2212;1</sup> was achieved at 10&#xa0;mM, highlighting the sensor&#x2019;s diagnostic potential. However, challenges remain at very low concentrations (0.01&#x2013;0.1&#xa0;mM), where angular shifts, sensitivity, and signal-to-noise ratio were negligible.</p>
</abstract>
<kwd-group>
<kwd>surface plasmon resonance</kwd>
<kwd>MoS<sub>2</sub>
</kwd>
<kwd>silicon nitrite</kwd>
<kwd>SARS-CoV-2</kwd>
<kwd>biosensor</kwd>
</kwd-group>
<contract-num rid="cn001">POA_VIN-56</contract-num>
<contract-sponsor id="cn001">Universidad T&#xe9;cnica Particular de Loja<named-content content-type="fundref-id">10.13039/100019349</named-content>
</contract-sponsor>
<custom-meta-wrap>
<custom-meta>
<meta-name>section-at-acceptance</meta-name>
<meta-value>Nanoelectronics</meta-value>
</custom-meta>
</custom-meta-wrap>
</article-meta>
</front>
<body>
<sec id="s1">
<title>1 Introduction</title>
<p>The COVID-19 (coronavirus disease 2019) pandemic, caused by the SARS-CoV-2 virus (<xref ref-type="bibr" rid="B33">Yang et al., 2024</xref>), has underlined the global need for advanced diagnostic tools that can address the growing challenges associated with rapid detection and monitoring (<xref ref-type="bibr" rid="B15">Liu et al., 2024</xref>). SARS-CoV-2, a single-stranded RNA (ribonucleic acid) virus with a characteristic spike protein that binds to the ACE2 receptor in human cells (<xref ref-type="bibr" rid="B6">Erkihun et al., 2024</xref>), has demonstrated unprecedented transmissibility and adaptability. Early and accurate detection of this virus is essential to prevent its spread and monitor emerging variants (<xref ref-type="bibr" rid="B35">Zhu et al., 2024</xref>), which may impact public health interventions and the efficacy of vaccines and treatments. While molecular techniques such as reverse transcription polymerase chain reaction (RT-PCR) remain the benchmark for sensitivity and specificity (<xref ref-type="bibr" rid="B21">Sajal et al., 2024</xref>), their dependence on centralized laboratories, skilled personnel, and specialized equipment makes them less suitable for widespread, decentralized testing. These limitations have motivated the exploration of alternative methods (<xref ref-type="bibr" rid="B10">Huggett et al., 2021</xref>), including biosensor-based platforms, to complement existing molecular diagnostics.</p>
<p>Biosensors offer a compelling solution to the limitations of conventional methods by enabling label-free, real-time, and highly sensitive detection of viral biomarkers such as RNA (<xref ref-type="bibr" rid="B11">Iravani, 2020</xref>), antigens (<xref ref-type="bibr" rid="B4">Cerutti et al., 2020</xref>), or antibodies (<xref ref-type="bibr" rid="B5">Drobysh et al., 2024</xref>). These devices integrate a biological recognition element, such as antibodies, aptamers, or nucleic acids, with a physical transducer to convert biological interactions into quantifiable signals (<xref ref-type="bibr" rid="B12">Justino et al., 2015</xref>). Surface plasmon resonance (SPR)-based biosensors (<xref ref-type="bibr" rid="B27">Tene et al., 2024a</xref>), in particular, have emerged as a promising technology for virus detection due to their high sensitivity to refractive index changes at the sensor surface (<xref ref-type="bibr" rid="B19">Patel and Parmar, 2021</xref>). SPR sensors exploit the resonant oscillation of free electrons at the interface between a metal and a dielectric medium (<xref ref-type="bibr" rid="B29">Tene et al., 2023a</xref>) under specific light conditions. These sensors not only allow the detection of viral components without the need for labeling but also provide real-time data, which is crucial in clinical and point-of-care settings.</p>
<p>It is important to remark that field-effect transistor (FET) modules have been widely explored for COVID-19 sensing due to their high sensitivity and rapid detection capabilities, leveraging the exceptional electronic properties of low-dimensional materials (<xref ref-type="bibr" rid="B22">Sengupta and Hussain, 2021</xref>), such as high carrier mobility and tunable bandgap. However, FET sensors often face challenges related to stability, signal drift, and the complexity of surface functionalization, which can limit their scalability for practical applications.</p>
<p>Recent advances in SPR biosensors have focused on integrating nanomaterials, particularly two-dimensional (2D) materials (<xref ref-type="bibr" rid="B20">Pisarra et al., 2022</xref>), to enhance sensitivity and specificity. 2D materials, such as graphene/graphene derivatives (<xref ref-type="bibr" rid="B28">Tene et al., 2023b</xref>) and transition metal dichalcogenides (TMDs) like molybdenum disulfide (MoS&#x2082;) (<xref ref-type="bibr" rid="B7">Ghodrati et al., 2024</xref>), exhibit unique physicochemical properties that make them attractive for biosensing applications. MoS&#x2082;, for instance, combines a high surface-to-volume ratio, strong light-matter interaction, and excellent electronic properties (<xref ref-type="bibr" rid="B14">Li and Zhu, 2015</xref>), which are critical for amplifying the sensor&#x2019;s response to biomolecular interactions. Functionalized MoS&#x2082; surfaces can immobilize biomolecules such as single-stranded DNA (ssDNA) or aptamers with high stability and specificity (<xref ref-type="bibr" rid="B8">Haque and Rouf, 2021</xref>), enabling the detection of SARS-CoV-2 RNA or spike proteins with interesting precision.</p>
<p>Despite the progress in integrating 2D materials into SPR biosensors, challenges remain in optimizing the multilayer configurations required for high-performance sensors. While prior studies have explored the use of graphene-based materials (<xref ref-type="bibr" rid="B23">Sindona et al., 2019</xref>) or hybrid structures (<xref ref-type="bibr" rid="B3">Cai et al., 2022</xref>) to enhance plasmonic properties, they often rely on fixed material dimensions and do not systematically investigate the impact of layer thickness on sensor performance. For example, a recent study proposed a graphene-coated SPR biosensor using PtSe&#x2082; to enhance sensitivity (<xref ref-type="bibr" rid="B1">Akib et al., 2021</xref>), achieving promising results through numerical simulations. However, this approach did not include experimental approach or a detailed exploration of how variations in layer thickness influence key performance metrics such as sensitivity, full-width at half maximum (FWHM), and figure of merit (FoM).</p>
<p>In this context, our work aims to address these gaps by presenting a systematic optimization of a MoS&#x2082;-based SPR biosensor for SARS-CoV-2 detection at different concentrations. The sensor comprises a multilayer architecture including a silver (Ag) metallic layer, a silicon nitride (Si&#x2083;N&#x2084;) dielectric spacer, and a functionalized MoS&#x2082; layer immobilized with thiol-tethered ssDNA. By varying the thickness of each layer, we comprehensively evaluate physical and performance metrics, including attenuation, FWHM, angle shift variation, sensitivity to refractive index changes, detection accuracy, quality factor (QF), FoM, limit of detection (LoD), and signal-to-noise ratio (SNR). This approach allows us to systematically understand the interplay between layer thickness, material properties, and sensor performance, providing critical insights for designing SPR biosensors with enhanced detection capabilities.</p>
<p>Hence, by tailoring each layer of the sensor to achieve optimal performance, this study meaningfully advances the capabilities of SPR biosensors for SARS-CoV-2 detection. Beyond the immediate application to COVID-19 diagnostics, the findings of this study provide a versatile framework for developing biosensors targeting other viral pathogens. This work demonstrates the potential of SPR technology for addressing current diagnostic challenges and paves the way for scalable, rapid, and accurate detection platforms that can play a key role in future pandemic preparedness.</p>
</sec>
<sec sec-type="methods" id="s2">
<title>2 Methodology</title>
<sec id="s2-1">
<title>2.1 Sensor building</title>
<p>The proposed biosensor, illustrated in <xref ref-type="fig" rid="F1">Figure 1</xref>, leverages a multilayered architecture integrated into a SPR configuration based on the Kretschmann prism coupling method (<xref ref-type="bibr" rid="B34">Zheng et al., 2024</xref>). At the sensor&#x2019;s core lies the BK-7 prism, which serves as the substrate and optical foundation. The prism plays a critical role in coupling incident light into the system, enabling the excitation of surface plasmons at the metal-dielectric interface. By directing polarized light at a specific angle (&#x3b8;), the prism facilitates the resonance condition required for SPR, where a sharp dip in reflected light intensity occurs.</p>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption>
<p>Illustration of the proposed biosensor for virus detection by using the surface plasmon resonance (SPR) approach.</p>
</caption>
<graphic xlink:href="fnano-06-1505751-g001.tif"/>
</fig>
<p>Above the prism is the Ag layer, which forms the metal-dielectric interface crucial for surface plasmon generation. Silver is chosen due to its exceptional plasmonic properties (<xref ref-type="bibr" rid="B18">Naik et al., 2013</xref>), including low propagation losses and strong plasmon resonance. This layer amplifies the sensor&#x2019;s sensitivity to subtle refractive index changes induced by biomolecular interactions. To enhance the propagation of surface plasmons and improve the adhesion between the Ag layer and subsequent functional layers, a Si&#x2083;N&#x2084; layer is incorporated as a dielectric spacer (<xref ref-type="bibr" rid="B17">Mudgal et al., 2020</xref>). The Si&#x2083;N&#x2084; layer is not only a structural component but also a functional one, as its thickness directly influences key optical parameters, such as the FWHM of the resonance curve and the angle shift variation (<xref ref-type="bibr" rid="B26">Tene et al., 2024b</xref>). By systematically varying the thickness of the Si&#x2083;N&#x2084; layer, the SPR angle is fine-tuned to maximize sensitivity and SNR.</p>
<p>Above the dielectric spacer lies the MoS&#x2082; layer, a 2D material that meaningfully enhances the sensor&#x2019;s functionality. MoS&#x2082; amplifies the local refractive index changes upon biomolecular binding. Its high refractive index further enhances the SPR signal, while its surface chemistry allows for robust functionalization. In this design, the MoS&#x2082; layer is functionalized with thiol groups, enabling the covalent attachment of ssDNA probes. These probes are designed to specifically hybridize with SARS-CoV-2 RNA, making the biosensor highly selective for viral detection.</p>
<p>The topmost layer, consisting of thiol-tethered ssDNA, serves as the biological recognition element of the sensor. The thiol groups provide a stable attachment to the MoS&#x2082; layer, while the ssDNA sequences offer high specificity for complementary SARS-CoV-2 RNA targets. When the viral RNA binds to the ssDNA, it induces a localized change in the refractive index at the sensor surface. This change is translated into an SPR angle shift (<xref ref-type="fig" rid="F1">Figure 1</xref>), which is detected by the optical system. The specificity of the thiol-tethered ssDNA ensures that the biosensor is not only sensitive but also selective, minimizing false-positive signals from non-target molecules.</p>
</sec>
<sec id="s2-2">
<title>2.2 Theoretical framework</title>
<p>A numerical analysis is employed to calculate the reflectance curve using the transfer matrix method (TMM) and Fresnel equations, as described in (<xref ref-type="bibr" rid="B30">Tene et al., 2024c</xref>; <xref ref-type="bibr" rid="B32">Varasteanu, 2020</xref>). This approach allows for the systematic modeling of light propagation through a multilayer system by considering the optical properties and thickness of each layer. The thickness of each layer is defined along the perpendicular axis (<italic>z</italic>-axis), which is the direction normal to the plane of the layers. The optical behavior at the interfaces between adjacent layers is governed by boundary conditions that ensure the continuity of the electric and magnetic field components of the electromagnetic wave.</p>
<p>The boundary conditions are applied at the interfaces to connect the electromagnetic fields across each layer. At the first layer, located at <inline-formula id="inf1">
<mml:math id="m1">
<mml:mrow>
<mml:mi>Z</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mi>Z</mml:mi>
<mml:mn>1</mml:mn>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0</mml:mn>
</mml:mrow>
</mml:math>
</inline-formula>, the incident wave interacts with the multilayer structure, and its reflection and transmission coefficients are calculated. Similarly, at the final layer, the wave exits the structure at <inline-formula id="inf2">
<mml:math id="m2">
<mml:mrow>
<mml:mi>Z</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mi>Z</mml:mi>
<mml:mrow>
<mml:mi>n</mml:mi>
<mml:mo>&#x2212;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>, where <italic>n</italic> represents the total number of layers in the system. These boundary conditions ensure that the physical constraints of the electromagnetic wave, such as the conservation of energy and phase continuity, are satisfied across all interfaces.</p>
<p>The <italic>Z</italic>-coordinate represents the position along the thickness of the multilayer structure, with <inline-formula id="inf3">
<mml:math id="m3">
<mml:mrow>
<mml:msub>
<mml:mi>Z</mml:mi>
<mml:mn>1</mml:mn>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0</mml:mn>
</mml:mrow>
</mml:math>
</inline-formula> marking the start of the first layer (e.g., the BK7 prism) and <inline-formula id="inf4">
<mml:math id="m4">
<mml:mrow>
<mml:msub>
<mml:mi>Z</mml:mi>
<mml:mrow>
<mml:mi>n</mml:mi>
<mml:mo>&#x2212;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> corresponding to the end of the last layer (e.g., the ssDNA functionalization layer). The TMM calculates the reflectance by constructing a matrix for each layer based on its refractive index, thickness, and incident angle of the light. These matrices are combined using the boundary conditions to derive the complete reflectance and transmittance of the system. This method enables accurate modeling of the interaction between light and the multilayer structure, providing insights into the sensor&#x2019;s performance under varying configurations.</p>
<p>Then, the transfer matrix describes the relationship between the tangential components of the electric and magnetic fields as:<disp-formula id="e1">
<mml:math id="m5">
<mml:mrow>
<mml:mrow>
<mml:mfenced open="[" close="]" separators="&#x7c;">
<mml:mrow>
<mml:mtable columnalign="center">
<mml:mtr>
<mml:mtd>
<mml:msub>
<mml:mi mathvariant="normal">E</mml:mi>
<mml:mn>1</mml:mn>
</mml:msub>
</mml:mtd>
</mml:mtr>
<mml:mtr>
<mml:mtd>
<mml:msub>
<mml:mi mathvariant="normal">H</mml:mi>
<mml:mn>1</mml:mn>
</mml:msub>
</mml:mtd>
</mml:mtr>
</mml:mtable>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mo>&#x3d;</mml:mo>
<mml:mi mathvariant="normal">M</mml:mi>
<mml:mrow>
<mml:mfenced open="[" close="]" separators="&#x7c;">
<mml:mrow>
<mml:mtable columnalign="center">
<mml:mtr>
<mml:mtd>
<mml:msub>
<mml:mi mathvariant="normal">E</mml:mi>
<mml:mrow>
<mml:mi mathvariant="normal">N</mml:mi>
<mml:mo>&#x2212;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
</mml:msub>
</mml:mtd>
</mml:mtr>
<mml:mtr>
<mml:mtd>
<mml:msub>
<mml:mi mathvariant="normal">H</mml:mi>
<mml:mrow>
<mml:mi mathvariant="normal">N</mml:mi>
<mml:mo>&#x2212;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
</mml:msub>
</mml:mtd>
</mml:mtr>
</mml:mtable>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mrow>
</mml:math>
</disp-formula>where, <inline-formula id="inf5">
<mml:math id="m6">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="normal">E</mml:mi>
<mml:mn>1</mml:mn>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>, <inline-formula id="inf6">
<mml:math id="m7">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="normal">H</mml:mi>
<mml:mn>1</mml:mn>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>, <inline-formula id="inf7">
<mml:math id="m8">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="normal">E</mml:mi>
<mml:mrow>
<mml:mi mathvariant="normal">N</mml:mi>
<mml:mo>&#x2212;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>, and <inline-formula id="inf8">
<mml:math id="m9">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="normal">H</mml:mi>
<mml:mrow>
<mml:mi mathvariant="normal">N</mml:mi>
<mml:mo>&#x2212;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> represent the tangential components of electric and magnetic fields at the first and last layer interfaces, respectively. <inline-formula id="inf9">
<mml:math id="m10">
<mml:mrow>
<mml:mi mathvariant="normal">M</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> is represented by elements <inline-formula id="inf10">
<mml:math id="m11">
<mml:mrow>
<mml:msub>
<mml:mi>M</mml:mi>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mi>j</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> as:<disp-formula id="e2">
<mml:math id="m12">
<mml:mrow>
<mml:mi mathvariant="normal">M</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mrow>
<mml:mstyle displaystyle="true">
<mml:munderover>
<mml:mo>&#x220f;</mml:mo>
<mml:mrow>
<mml:mi>k</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>2</mml:mn>
</mml:mrow>
<mml:mrow>
<mml:mi>N</mml:mi>
<mml:mo>&#x2212;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
</mml:munderover>
</mml:mstyle>
<mml:mrow>
<mml:msub>
<mml:mi>M</mml:mi>
<mml:mi>k</mml:mi>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mrow>
<mml:mfenced open="[" close="]" separators="&#x7c;">
<mml:mrow>
<mml:mtable columnalign="center">
<mml:mtr>
<mml:mtd>
<mml:msub>
<mml:mi>M</mml:mi>
<mml:mn>11</mml:mn>
</mml:msub>
</mml:mtd>
<mml:mtd>
<mml:msub>
<mml:mi>M</mml:mi>
<mml:mn>12</mml:mn>
</mml:msub>
</mml:mtd>
</mml:mtr>
<mml:mtr>
<mml:mtd>
<mml:msub>
<mml:mi>M</mml:mi>
<mml:mn>21</mml:mn>
</mml:msub>
</mml:mtd>
<mml:mtd>
<mml:msub>
<mml:mi>M</mml:mi>
<mml:mn>22</mml:mn>
</mml:msub>
</mml:mtd>
</mml:mtr>
</mml:mtable>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mrow>
</mml:mrow>
</mml:mrow>
</mml:math>
</disp-formula>
</p>
<p>And <inline-formula id="inf11">
<mml:math id="m13">
<mml:mrow>
<mml:msub>
<mml:mi>M</mml:mi>
<mml:mi>k</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is defined as:<disp-formula id="e3">
<mml:math id="m14">
<mml:mrow>
<mml:msub>
<mml:mi>M</mml:mi>
<mml:mi>k</mml:mi>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mrow>
<mml:mfenced open="[" close="]" separators="&#x7c;">
<mml:mrow>
<mml:mtable columnalign="center">
<mml:mtr>
<mml:mtd>
<mml:mrow>
<mml:mi>cos</mml:mi>
<mml:mo>&#x2061;</mml:mo>
<mml:msub>
<mml:mi>&#x3b2;</mml:mi>
<mml:mi>k</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mtd>
<mml:mtd>
<mml:mrow>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>i</mml:mi>
<mml:mo>&#x2061;</mml:mo>
<mml:mi>sin</mml:mi>
<mml:mo>&#x2061;</mml:mo>
<mml:msub>
<mml:mi>&#x3b2;</mml:mi>
<mml:mi>k</mml:mi>
</mml:msub>
<mml:mo>/</mml:mo>
<mml:msub>
<mml:mi>q</mml:mi>
<mml:mi>k</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mtd>
</mml:mtr>
<mml:mtr>
<mml:mtd>
<mml:mrow>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>i</mml:mi>
<mml:msub>
<mml:mi>q</mml:mi>
<mml:mi>k</mml:mi>
</mml:msub>
<mml:mtext>&#x2009;</mml:mtext>
<mml:mi>sin</mml:mi>
<mml:mo>&#x2061;</mml:mo>
<mml:msub>
<mml:mi>&#x3b2;</mml:mi>
<mml:mi>k</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mtd>
<mml:mtd>
<mml:mrow>
<mml:mi>cos</mml:mi>
<mml:mo>&#x2061;</mml:mo>
<mml:msub>
<mml:mi>&#x3b2;</mml:mi>
<mml:mi>k</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mtd>
</mml:mtr>
</mml:mtable>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mrow>
</mml:math>
</disp-formula>here, <inline-formula id="inf12">
<mml:math id="m15">
<mml:mrow>
<mml:mi>k</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> is an integer number. Additionally, <inline-formula id="inf13">
<mml:math id="m16">
<mml:mrow>
<mml:msub>
<mml:mi>&#x3b2;</mml:mi>
<mml:mi>k</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is the phase thickness and <inline-formula id="inf14">
<mml:math id="m17">
<mml:mrow>
<mml:msub>
<mml:mi>q</mml:mi>
<mml:mi>k</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is the refractive index in each layer:<disp-formula id="e4">
<mml:math id="m18">
<mml:mrow>
<mml:msub>
<mml:mi>&#x3b2;</mml:mi>
<mml:mi>k</mml:mi>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mn>2</mml:mn>
<mml:mi>&#x3c0;</mml:mi>
<mml:msub>
<mml:mi>d</mml:mi>
<mml:mi>k</mml:mi>
</mml:msub>
</mml:mrow>
<mml:msub>
<mml:mi>&#x3bb;</mml:mi>
<mml:mn>0</mml:mn>
</mml:msub>
</mml:mfrac>
<mml:msqrt>
<mml:mrow>
<mml:msub>
<mml:mi>&#x3b5;</mml:mi>
<mml:mi>k</mml:mi>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:msubsup>
<mml:mi>n</mml:mi>
<mml:mn>1</mml:mn>
<mml:mn>2</mml:mn>
</mml:msubsup>
<mml:mo>&#x2061;</mml:mo>
<mml:msup>
<mml:mi>sin</mml:mi>
<mml:mn>2</mml:mn>
</mml:msup>
<mml:mo>&#x2061;</mml:mo>
<mml:mi>&#x3b8;</mml:mi>
</mml:mrow>
</mml:msqrt>
</mml:mrow>
</mml:math>
</disp-formula>
</p>
<p>And<disp-formula id="e5">
<mml:math id="m19">
<mml:mrow>
<mml:msub>
<mml:mi>q</mml:mi>
<mml:mi>k</mml:mi>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:msqrt>
<mml:mrow>
<mml:msub>
<mml:mi>&#x3b5;</mml:mi>
<mml:mi>k</mml:mi>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:msubsup>
<mml:mi>n</mml:mi>
<mml:mn>1</mml:mn>
<mml:mn>2</mml:mn>
</mml:msubsup>
<mml:mo>&#x2061;</mml:mo>
<mml:msup>
<mml:mi>sin</mml:mi>
<mml:mn>2</mml:mn>
</mml:msup>
<mml:mo>&#x2061;</mml:mo>
<mml:mi>&#x3b8;</mml:mi>
</mml:mrow>
</mml:msqrt>
</mml:mrow>
<mml:mrow>
<mml:msub>
<mml:mi>&#x3b5;</mml:mi>
<mml:mi>k</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:math>
</disp-formula>where, <inline-formula id="inf15">
<mml:math id="m20">
<mml:mrow>
<mml:mi>&#x3b8;</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> is the angle of incidence, <inline-formula id="inf16">
<mml:math id="m21">
<mml:mrow>
<mml:msub>
<mml:mi>&#x3bb;</mml:mi>
<mml:mn>0</mml:mn>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is the incident wavelength light, <inline-formula id="inf17">
<mml:math id="m22">
<mml:mrow>
<mml:msub>
<mml:mi>n</mml:mi>
<mml:mn>1</mml:mn>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is the refractive index of the prism, <inline-formula id="inf18">
<mml:math id="m23">
<mml:mrow>
<mml:msub>
<mml:mi>d</mml:mi>
<mml:mi>k</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is the thickness layer, and the local dielectric function <inline-formula id="inf19">
<mml:math id="m24">
<mml:mrow>
<mml:mi>&#x3b5;</mml:mi>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:msub>
<mml:mi>&#x3bb;</mml:mi>
<mml:mn>0</mml:mn>
</mml:msub>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula> can be adopted as <inline-formula id="inf20">
<mml:math id="m25">
<mml:mrow>
<mml:mi>n</mml:mi>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:msub>
<mml:mi>&#x3bb;</mml:mi>
<mml:mn>0</mml:mn>
</mml:msub>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula>. Hence, the total reflection analysis of the N-layer system is obtained as:<disp-formula id="e6">
<mml:math id="m26">
<mml:mrow>
<mml:mi>R</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:msup>
<mml:mrow>
<mml:mfenced open="|" close="|" separators="&#x7c;">
<mml:mrow>
<mml:mfrac>
<mml:mrow>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:msub>
<mml:mi>M</mml:mi>
<mml:mn>11</mml:mn>
</mml:msub>
<mml:mo>&#x2b;</mml:mo>
<mml:msub>
<mml:mi>M</mml:mi>
<mml:mn>12</mml:mn>
</mml:msub>
<mml:msub>
<mml:mi>q</mml:mi>
<mml:mi>N</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:msub>
<mml:mi>q</mml:mi>
<mml:mn>1</mml:mn>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:msub>
<mml:mi>M</mml:mi>
<mml:mn>21</mml:mn>
</mml:msub>
<mml:mo>&#x2b;</mml:mo>
<mml:msub>
<mml:mi>M</mml:mi>
<mml:mn>22</mml:mn>
</mml:msub>
<mml:msub>
<mml:mi>q</mml:mi>
<mml:mi>N</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mrow>
<mml:mrow>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:msub>
<mml:mi>M</mml:mi>
<mml:mn>11</mml:mn>
</mml:msub>
<mml:mo>&#x2b;</mml:mo>
<mml:msub>
<mml:mi>M</mml:mi>
<mml:mn>12</mml:mn>
</mml:msub>
<mml:msub>
<mml:mi>q</mml:mi>
<mml:mi>N</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:msub>
<mml:mi>q</mml:mi>
<mml:mn>1</mml:mn>
</mml:msub>
<mml:mo>&#x2b;</mml:mo>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:msub>
<mml:mi>M</mml:mi>
<mml:mn>21</mml:mn>
</mml:msub>
<mml:mo>&#x2b;</mml:mo>
<mml:msub>
<mml:mi>M</mml:mi>
<mml:mn>22</mml:mn>
</mml:msub>
<mml:msub>
<mml:mi>q</mml:mi>
<mml:mi>N</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msup>
</mml:mrow>
</mml:math>
</disp-formula>
</p>
<p>by using Equation 6 the SPR curve as a function of the angle of incidence is computed. To analyze the performance of the biosensor is necessary to consider the following metrics. The sensitivity of the biosensors (<inline-formula id="inf21">
<mml:math id="m27">
<mml:mrow>
<mml:mi>S</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>) is defined as the multiplication of the sensitivity to the refractive index change (<inline-formula id="inf22">
<mml:math id="m28">
<mml:mrow>
<mml:msub>
<mml:mi>S</mml:mi>
<mml:mrow>
<mml:mi>R</mml:mi>
<mml:mi>I</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>) and the adsorption efficiency of the target analyte (<inline-formula id="inf23">
<mml:math id="m29">
<mml:mrow>
<mml:mi>E</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>) as:<disp-formula id="e7">
<mml:math id="m30">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mi>S</mml:mi>
<mml:mrow>
<mml:mi>R</mml:mi>
<mml:mi>I</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x22C5;</mml:mo>
<mml:mi>E</mml:mi>
</mml:mrow>
</mml:math>
</disp-formula>
</p>
<p>For biosensor optimization, we focus on the sensitivity enhancement (<inline-formula id="inf24">
<mml:math id="m31">
<mml:mrow>
<mml:mo>&#x2206;</mml:mo>
<mml:msub>
<mml:mi>S</mml:mi>
<mml:mrow>
<mml:mi>R</mml:mi>
<mml:mi>I</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>) by optimizing each layer in water and PBS solutions, denoted as:<disp-formula id="e8">
<mml:math id="m32">
<mml:mrow>
<mml:mo>&#x2206;</mml:mo>
<mml:msub>
<mml:mi>S</mml:mi>
<mml:mrow>
<mml:mi>R</mml:mi>
<mml:mi>I</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:msubsup>
<mml:mi>S</mml:mi>
<mml:mrow>
<mml:mi>R</mml:mi>
<mml:mi>I</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi>P</mml:mi>
<mml:mi>B</mml:mi>
<mml:mi>S</mml:mi>
</mml:mrow>
</mml:msubsup>
<mml:mo>&#x2212;</mml:mo>
<mml:msubsup>
<mml:mi>S</mml:mi>
<mml:mrow>
<mml:mi>R</mml:mi>
<mml:mi>I</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi>w</mml:mi>
<mml:mi>a</mml:mi>
<mml:mi>t</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>r</mml:mi>
</mml:mrow>
</mml:msubsup>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mo>/</mml:mo>
<mml:msubsup>
<mml:mi>S</mml:mi>
<mml:mrow>
<mml:mi>R</mml:mi>
<mml:mi>I</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi>w</mml:mi>
<mml:mi>a</mml:mi>
<mml:mi>t</mml:mi>
<mml:mi>e</mml:mi>
<mml:mi>r</mml:mi>
</mml:mrow>
</mml:msubsup>
</mml:mrow>
</mml:math>
</disp-formula>
</p>
<p>The sensitivity to the refractive index change can be expressed as:<disp-formula id="e9">
<mml:math id="m33">
<mml:mrow>
<mml:msub>
<mml:mi>S</mml:mi>
<mml:mrow>
<mml:mi>R</mml:mi>
<mml:mi>I</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mo>&#x2206;</mml:mo>
<mml:mi>&#x3b8;</mml:mi>
<mml:mo>/</mml:mo>
<mml:mo>&#x2206;</mml:mo>
<mml:mi>n</mml:mi>
</mml:mrow>
</mml:math>
</disp-formula>
</p>
<p>The parameter <inline-formula id="inf25">
<mml:math id="m34">
<mml:mrow>
<mml:mo>&#x2206;</mml:mo>
<mml:mi>&#x3b8;</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> represents the angle shift variation and <inline-formula id="inf26">
<mml:math id="m35">
<mml:mrow>
<mml:mo>&#x2206;</mml:mo>
<mml:mi>n</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> is the change in refractive index. The detection accuracy (DA) can be written in terms of <inline-formula id="inf27">
<mml:math id="m36">
<mml:mrow>
<mml:mo>&#x2206;</mml:mo>
<mml:mi>&#x3b8;</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> and FWHM as:<disp-formula id="e10">
<mml:math id="m37">
<mml:mrow>
<mml:mtext>DA</mml:mtext>
<mml:mo>&#x3d;</mml:mo>
<mml:mo>&#x2206;</mml:mo>
<mml:mi>&#x3b8;</mml:mi>
<mml:mo>/</mml:mo>
<mml:mtext>FWHM</mml:mtext>
</mml:mrow>
</mml:math>
</disp-formula>
</p>
<p>Quality factor (QF) can be expressed in terms of <inline-formula id="inf28">
<mml:math id="m38">
<mml:mrow>
<mml:mi>S</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> and FWHM as:<disp-formula id="e11">
<mml:math id="m39">
<mml:mrow>
<mml:mtext>QF</mml:mtext>
<mml:mo>&#x3d;</mml:mo>
<mml:mi>S</mml:mi>
<mml:mo>/</mml:mo>
<mml:mtext>FWHM</mml:mtext>
</mml:mrow>
</mml:math>
</disp-formula>
</p>
<p>In addition, to compute the FoM, LoD, and SNR, the related equations can be expressed as (<xref ref-type="bibr" rid="B31">Uddin et al., 2021</xref>; <xref ref-type="bibr" rid="B9">Hu et al., 2021</xref>):<disp-formula id="e12">
<mml:math id="m40">
<mml:mrow>
<mml:mtext>FoM</mml:mtext>
<mml:mo>&#x3d;</mml:mo>
<mml:mtext>QF</mml:mtext>
<mml:mo>/</mml:mo>
<mml:mtext>Rmin</mml:mtext>
</mml:mrow>
</mml:math>
</disp-formula>
<disp-formula id="e13">
<mml:math id="m41">
<mml:mrow>
<mml:mtext>LoD</mml:mtext>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mo>&#x2206;</mml:mo>
<mml:mi>n</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mo>&#x2206;</mml:mo>
<mml:mi>&#x3b8;</mml:mi>
</mml:mrow>
</mml:mfrac>
<mml:mo>&#xd7;</mml:mo>
<mml:mn>0.005</mml:mn>
</mml:mrow>
</mml:math>
</disp-formula>
<disp-formula id="e14">
<mml:math id="m42">
<mml:mrow>
<mml:mtext>SNR</mml:mtext>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mo>&#x2206;</mml:mo>
<mml:mi>&#x3b8;</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi>F</mml:mi>
<mml:mi>W</mml:mi>
<mml:mi>H</mml:mi>
<mml:mi>M</mml:mi>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:math>
</disp-formula>where, <inline-formula id="inf29">
<mml:math id="m43">
<mml:mtext>Rmin</mml:mtext>
</mml:math>
</inline-formula> is the resonance minimum from SPR curve and 0.005 is expressed in degree (<inline-formula id="inf30">
<mml:math id="m44">
<mml:mrow>
<mml:mn>0.005</mml:mn>
<mml:mo>&#xb0;</mml:mo>
</mml:mrow>
</mml:math>
</inline-formula>). All computations in this study were performed using a data sampling density of 50,000 points. This high sampling rate was chosen to ensure statistical accuracy, minimize numerical errors, and provide a robust basis for the analysis.</p>
</sec>
<sec id="s2-3">
<title>2.3 Systems configurations and initial parameters</title>
<p>
<xref ref-type="sec" rid="s11">Supplementary Table S1</xref> illustrates the systematic progression of the systems considered in this work to optimize the SPR biosensor for SARS-CoV-2 detection. It provides a overview of the incremental changes made to the sensor&#x2019;s architecture, ranging from the baseline configuration (Sys&#x2080;) to the fully functional systems incorporating advanced materials and specific biorecognition elements (Sys&#x2089;). The baseline system, Sys&#x2080;, consists of the simplest architecture: a prism, a silver layer, and water as the sensing medium. This configuration serves as a starting point for computing sensitivity enhancements across more complex systems. In Sys&#x2081;, the sensing medium is changed to phosphate-buffered saline (PBS), a biologically relevant environment, to bring the system closer to realistic conditions without altering the structural layers.</p>
<p>From Sys&#x2082; onward, additional layers are incrementally introduced to evaluate their contribution to the biosensor&#x2019;s functionality. Each subsequent configuration builds upon the previous one by incorporating either Si&#x2083;N&#x2084;, MoS&#x2082;, or thiol-tethered ssDNA. For instance, Sys&#x2082; introduces Si&#x2083;N&#x2084; to improve plasmonic performance, while Sys&#x2083; functionalizes this layer with ssDNA to add selectivity for detecting viral RNA. Similarly, Sys&#x2084; and Sys&#x2085; explore the standalone and functionalized use of MoS&#x2082;, respectively. More advanced configurations, such as Sys&#x2086;, Sys&#x2087;, Sys&#x2088;, and Sys&#x2089;, involve combinations of Si&#x2083;N&#x2084; and MoS&#x2082; in various arrangements, with or without functionalization.</p>
<p>On the other hand, <xref ref-type="sec" rid="s11">Supplementary Table S2</xref> provides the initial parameters used for the SPR biosensor configurations investigated in this study. These parameters show the refractive index and thickness of each material layer, along with references to the experimental or theoretical studies from which these values were derived (<xref ref-type="bibr" rid="B25">Su et al., 2013</xref>; <xref ref-type="bibr" rid="B16">Luke et al., 2015</xref>; <xref ref-type="bibr" rid="B13">Kumar et al., 2022</xref>; <xref ref-type="bibr" rid="B2">Akib et al., 2024</xref>). The BK-7 prism, which forms the substrate of the SPR biosensor, has a refractive index of 1.5151. However, its thickness is not reported because, in the numerical modeling approach used here, the prism is treated as an infinite medium for light propagation. This assumption simplifies the simulation process while maintaining the accuracy of the results, as the thickness of the prism does not directly influence the excitation of surface plasmons at the metal-dielectric interface. Similarly, the thickness values for the sensing media, i.e., water and PBS, are not included. In these cases, the sensing medium is considered a semi-infinite layer in the numerical calculations, as its role is to provide the refractive index environment above the biosensor&#x2019;s active layers. This treatment aligns with the typical approach in SPR modeling (<xref ref-type="bibr" rid="B24">Srivastava et al., 2020</xref>).</p>
<p>The Ag layer, with a refractive index of 0.056253 &#x2b; 4.2760i, has a well-defined thickness of 55&#xa0;nm. This thickness is optimized to achieve strong surface plasmon resonance and is consistent with values reported in the literature for SPR biosensors. The Si&#x2083;N&#x2084; layer, with a refractive index of 2.0394 and a thickness of 5&#xa0;nm, serves as a dielectric spacer. Its parameters are carefully chosen to enhance the propagation of surface plasmons and improve the adhesion of subsequent layers. The MoS&#x2082; layer has a refractive index of 5.0805 &#x2b; 1.1723i and a thickness of 0.65&#xa0;nm, corresponding to a monolayer. These values are derived from theoretical studies that accurately model the optical properties of MoS&#x2082; for plasmonic applications. Lastly, the thiol-tethered ssDNA layer has a refractive index of 1.462 and a thickness of 3.2&#xa0;nm, which corresponds to a typical monolayer of DNA immobilized on a substrate. As stated, this layer provides the biosensor with its biochemical specificity for detecting SARS-CoV-2 RNA.</p>
</sec>
</sec>
<sec sec-type="results|discussion" id="s3">
<title>3 Results and Discussion</title>
<sec id="s3-1">
<title>3.1 Selecting a suitable configuration</title>
<p>The results presented in <xref ref-type="fig" rid="F2">Figure 2</xref> and <xref ref-type="sec" rid="s11">Supplementary Table S3</xref> provide a detailed evaluation of the physical and performance metrics of the SPR biosensor configurations, systematically comparing their performance across different architectures. The SPR reflectance curves (<xref ref-type="fig" rid="F2">Figure 2A</xref>) highlight the changes in resonance behavior caused by the incremental addition of functional layers, while the numerical metrics of attenuation, FWHM, and sensitivity enhancement (<xref ref-type="sec" rid="s11">Supplementary Table S3</xref>) quantify the effects of these modifications. This comprehensive analysis is key to identifying the optimal configuration that balances plasmonic interaction, resonance resolution, and sensitivity.</p>
<fig id="F2" position="float">
<label>FIGURE 2</label>
<caption>
<p>
<bold>(A)</bold> SPR reflectance curves plotted as a function of the incidence angle for the configurations investigated in this study: Sys<sub>0</sub> in water and Sys<sub>1</sub>&#x2013;Sys<sub>9</sub> in a PBS solution. <bold>(B)</bold> Percentage attenuation of reflectance at the resonance dip for each configuration. <bold>(C)</bold> Full Width at Half Maximum (FWHM) of the resonance curve. <bold>(D)</bold> Percentage enhancement in sensitivity across all configurations, taking as the baseline, Sys<sub>0</sub>.</p>
</caption>
<graphic xlink:href="fnano-06-1505751-g002.tif"/>
</fig>
<p>The SPR curves (<xref ref-type="fig" rid="F2">Figures 2A, B</xref>) reveal how each system responds to changes in the angle of incidence. Sys&#x2080;, the baseline configuration in water, demonstrates a sharp and narrow resonance with minimal attenuation (0.023%), reflecting its simple and loss-minimized design. However, as additional layers are incorporated in Sys&#x2081; through Sys&#x2089;, the resonance depth increases, accompanied by broader curves and higher attenuation values. This trend is particularly pronounced in Sys&#x2084; to Sys&#x2088;, where the integration of MoS<sub>2</sub> and ssDNA meaningfully enhances plasmonic interaction. While increased attenuation (peaking at 20.55% in Sys&#x2088;) indicates stronger interaction with the functional layers, it must be balanced to prevent excessive broadening of the resonance curve, which could compromise detection resolution.</p>
<p>The broadening of the resonance is quantitatively captured by the FWHM values (<xref ref-type="fig" rid="F2">Figure 2C</xref>), which increase as the system evolves from Sys&#x2080; to Sys&#x2089;. The baseline system exhibits the narrowest FWHM (0.88&#xb0;), indicative of high-resolution performance but limited interaction with the sensing environment. As more layers are added, the FWHM values rise, reaching 2.97&#xb0; in Sys&#x2088;, the widest among the configurations. While broader FWHM can reduce the precision of resonance peak detection, in this context, it reflects the enhanced plasmonic response due to the optimized multilayer structure. This trade-off is critical, as the broadening is accompanied by significant sensitivity gains, underlining the benefits of the multilayer architecture.</p>
<p>The sensitivity enhancement, shown in <xref ref-type="fig" rid="F2">Figure 2D</xref>, provides a direct measure of the biosensor&#x2019;s ability to detect refractive index changes. Relative to the baseline Sys&#x2080;, sensitivity enhancement increases consistently across the configurations, with the highest value observed in Sys&#x2088; (7.50%). This result highlights the effectiveness of the combination of silicon nitride, molybdenum disulfide, and thiol-tethered DNA in optimizing the sensor&#x2019;s optical and biochemical interactions. The role of each layer in enhancing the refractive index contrast and enabling specific biomolecular binding is evident in the important performance gains of Sys&#x2088; compared to earlier systems. While Sys&#x2089; achieves a similar sensitivity (7.29%), its marginally reduced enhancement compared to Sys&#x2088; highlights the importance of layer arrangement and thickness optimization.</p>
</sec>
<sec id="s3-2">
<title>3.2 Silver optimization</title>
<p>The results in <xref ref-type="fig" rid="F3">Figure 3</xref> and <xref ref-type="sec" rid="s11">Supplementary Table S4</xref> describe the impact of varying Ag thickness on the performance of the Sys&#x2088; configuration. The SPR reflectance curves (<xref ref-type="fig" rid="F3">Figures 3A, B</xref>) reveal a clear relationship between Ag thickness and resonance behavior. For thinner layers, such as 40&#xa0;nm, the resonance dip is shallow, with an attenuation of 3.40%. This low attenuation indicates weaker plasmonic interaction and less effective light coupling. As the Ag thickness increases, the resonance dip becomes deeper, accompanied by a rise in attenuation, which reaches 53.13% for 65&#xa0;nm. However, thicker layers also introduce substantial optical losses, which reduce the efficiency of the system. At 45&#xa0;nm, attenuation is minimized at 0.17%, providing an effective balance between plasmonic coupling and energy conservation.</p>
<fig id="F3" position="float">
<label>FIGURE 3</label>
<caption>
<p>
<bold>(A)</bold> SPR reflectance curves plotted as a function of the silver thickness: Ag<sub>base</sub> in water (with the original parameters from <xref ref-type="sec" rid="s11">Supplementary Table S1</xref>) and Ag<sub>40</sub>&#x2013;Ag<sub>65</sub> in a PBS solution. <bold>(B)</bold> Percentage attenuation of reflectance at the resonance dip for each silver thickness. <bold>(C)</bold> Full Width at Half Maximum (FWHM) of the resonance curve. <bold>(D)</bold> Percentage enhancement in sensitivity across all thickness values, taking as the baseline, Ag<sub>base</sub>.</p>
</caption>
<graphic xlink:href="fnano-06-1505751-g003.tif"/>
</fig>
<p>The FWHM values (<xref ref-type="fig" rid="F3">Figure 3C</xref>) provide insight into the sharpness of the resonance peaks. At 40&#xa0;nm, the FWHM is the widest, measuring 4.56&#xb0;, indicating poor resolution and diffuse resonance behavior. Increasing the thickness to 45&#xa0;nm narrows the FWHM to 3.79&#xb0;, a significant improvement in resolution compared to thinner layers. Beyond 45&#xa0;nm, the narrowing trend becomes less pronounced, stabilizing around 2.81&#xb0; at 65&#xa0;nm. The narrowing of FWHM with increased thickness reflects better optical resolution, though the limited improvements at higher thicknesses do not justify the trade-offs in energy loss and attenuation.</p>
<p>Sensitivity enhancement (<xref ref-type="fig" rid="F3">Figure 3D</xref>) further emphasizes the performance improvements achieved with increasing Ag thickness. At 40&#xa0;nm, sensitivity enhancement is measured at 0.58%, reflecting the reduced interaction between the plasmonic layer and the sensing medium. This value increases steadily with thickness, peaking at 0.86% for 65&#xa0;nm. However, the incremental gains between 45&#xa0;nm (0.67%) and 65&#xa0;nm do not compensate for the higher attenuation and reduced resolution benefits. At 45&#xa0;nm, sensitivity enhancement is sufficient for effective detection, while the low attenuation and improved resolution offer a more balanced performance. Hence, the selection of 45&#xa0;nm as the optimal Ag thickness is supported by its ability to balance all critical performance metrics. The FWHM at 45&#xa0;nm reflects improved resolution without the unnecessary broadening seen at lower thicknesses. Furthermore, its sensitivity enhancement, while not the highest, is competitive and provides reliable detection without the drawbacks associated with thicker layers.</p>
</sec>
<sec id="s3-3">
<title>3.3 Silicon nitride optimization</title>
<p>The results in <xref ref-type="fig" rid="F4">Figure 4</xref> and <xref ref-type="sec" rid="s11">Supplementary Table S5</xref> examine the impact of varying the thickness of S&#x2083;N&#x2084; on the performance of the Sys&#x2088; configuration. The SPR reflectance curves (<xref ref-type="fig" rid="F4">Figures 4A,B</xref>) demonstrate the effect of S&#x2083;N&#x2084; thickness on the resonance behavior. At a thickness of 5&#xa0;nm, the resonance dip is sharp but shallow, corresponding to an attenuation of 0.17%. This low attenuation indicates limited interaction between the plasmonic layer and the dielectric interface, reducing the system&#x2019;s ability to effectively respond to refractive index changes. As the thickness increases, the resonance dip becomes more pronounced, peaking at 89.80% for 20&#xa0;nm. However, such high attenuation introduces excessive optical losses, which can degrade signal response. At 13&#xa0;nm, attenuation is moderate at 6.99%, providing a balanced interaction that enhances plasmonic coupling without significant energy dissipation.</p>
<fig id="F4" position="float">
<label>FIGURE 4</label>
<caption>
<p>
<bold>(A)</bold> SPR reflectance curves plotted as a function of the silicon nitride thickness: S<sub>3</sub>N<sub>4_base</sub> in water (with the optimized Ag thickness and original parameters from <xref ref-type="sec" rid="s11">Supplementary Table S1</xref>) and S<sub>3</sub>N<sub>4_5nm</sub>&#x2013;S<sub>3</sub>N<sub>4_20nm</sub> in a PBS solution. <bold>(B)</bold> Percentage attenuation of reflectance at the resonance dip for each silicon nitride thickness. <bold>(C)</bold> Full Width at Half Maximum (FWHM) of the resonance curve. <bold>(D)</bold> Percentage enhancement in sensitivity across all thickness values, taking as the baseline, S<sub>3</sub>N<sub>4_base</sub>.</p>
</caption>
<graphic xlink:href="fnano-06-1505751-g004.tif"/>
</fig>
<p>The FWHM values (<xref ref-type="fig" rid="F4">Figure 4C</xref>) offer further insight into the sharpness of the resonance peaks. At 5&#xa0;nm, the FWHM is narrow, measuring 3.89&#xb0;, reflecting high resolution but limited plasmonic response. As the thickness increases, the FWHM widens progressively, reaching 14.32&#xb0; at 20&#xa0;nm. This widening indicates reduced precision in detecting resonance shifts, which can impact the sensor&#x2019;s ability to resolve small refractive index changes. A thickness of 13&#xa0;nm achieves a FWHM of 6.76&#xb0;, representing an optimal trade-off between maintaining sufficient resolution and accommodating the broader resonance needed for enhanced sensitivity.</p>
<p>Sensitivity enhancement (<xref ref-type="fig" rid="F4">Figure 4D</xref>) highlights the sensor&#x2019;s performance in detecting refractive index changes. At 5&#xa0;nm, the enhancement is minimal (0.80%), reflecting limited sensitivity due to the reduced interaction at the interface. Sensitivity increases steadily with thickness, peaking at 17.64% for 15&#xa0;nm before slightly declining to 16.42% at 20&#xa0;nm. While thicker layers improve sensitivity, the diminishing returns beyond 13&#xa0;nm, coupled with the rapid increase in attenuation and FWHM, make thicker configurations less practical for more realistic applications. At 13&#xa0;nm, the sensitivity enhancement reaches 12.80%, providing a significant improvement without excessive trade-offs in signal response or resolution. The choice of 13&#xa0;nm reflects a strategic compromise that maximizes the effectiveness of the Sys&#x2088; configuration, supporting its application in precise and reliable biosensing for SARS-CoV-2 detection and beyond.</p>
</sec>
<sec id="s3-4">
<title>3.4 MoS<sub>2</sub> optimization</title>
<p>The results presented in <xref ref-type="fig" rid="F5">Figure 5</xref> and <xref ref-type="sec" rid="s11">Supplementary Table S6</xref> assess the effect of varying the number of MoS&#x2082; layers on the performance of the Sys&#x2088; configuration. The SPR reflectance curves (<xref ref-type="fig" rid="F5">Figures 5A, B</xref>) show that for a single layer, the resonance dip is sharp and well-defined, with attenuation at 6.99%. This moderate attenuation reflects efficient plasmonic interaction without introducing significant optical losses. As the number of layers increases, attenuation rises sharply, reaching 89.66% for six layers. This increase in attenuation indicates excessive energy losses that diminish the signal response, reducing its suitability for practical biosensing applications.</p>
<fig id="F5" position="float">
<label>FIGURE 5</label>
<caption>
<p>
<bold>(A)</bold> SPR reflectance curves plotted as a function of the number of MoS<sub>2</sub> layers: L1<sub>base</sub> in water (with the optimized Ag/S<sub>3</sub>N<sub>4</sub> thickness and original parameters from <xref ref-type="sec" rid="s11">Supplementary Table S1</xref>) and L1&#x2013;L6 in a PBS solution. <bold>(B)</bold> Percentage attenuation of reflectance at the resonance dip for each MoS<sub>2</sub> layer. <bold>(C)</bold> Full Width at Half Maximum (FWHM) of the resonance curve. <bold>(D)</bold> Percentage enhancement in sensitivity across all thickness values, taking as the baseline, L1<sub>base</sub>.</p>
</caption>
<graphic xlink:href="fnano-06-1505751-g005.tif"/>
</fig>
<p>The FWHM values (<xref ref-type="fig" rid="F5">Figure 5C</xref>) further highlight the effect of additional layers. For a single layer, the FWHM is narrow at 6.76&#xb0;, providing precise resolution and clear detection of resonance shifts. However, as the number of layers increases, the FWHM broadens significantly, reaching 16.64&#xb0; for six layers. This loss of resolution impacts the sensor&#x2019;s ability to accurately detect small refractive index changes. The narrow resonance peak observed with a single layer supports higher detection precision, making it the most effective option for applications requiring accuracy.</p>
<p>Sensitivity enhancement (<xref ref-type="fig" rid="F5">Figure 5D</xref>) reflects how the number of MoS&#x2082; layers influences the sensor&#x2019;s ability to detect refractive index changes. In this context, two layers achieve the highest sensitivity enhancement (4.71%), but this comes at the cost of higher attenuation (45.50%) and a wider FWHM (9.61&#xb0;). Beyond two layers, sensitivity enhancement declines steadily, reaching only 0.44% for six layers. Although two layers show a slight improvement in sensitivity compared to a single layer, the significant trade-offs in attenuation and resolution reduce their overall viability. The single-layer configuration provides sufficient sensitivity (1.19%) while maintaining superior resolution and lower attenuation. Then, these findings demonstrate that a single MoS&#x2082; layer provides the best balance of performance metrics, making it the most effective choice for the Sys&#x2088; configuration.</p>
</sec>
<sec id="s3-5">
<title>3.5 ssDNA optimization</title>
<p>The results in <xref ref-type="fig" rid="F6">Figure 6</xref> and <xref ref-type="sec" rid="s11">Supplementary Table S7</xref> evaluate the effect of varying ssDNA thickness on the performance of the Sys&#x2088; configuration. The SPR reflectance curves (<xref ref-type="fig" rid="F6">Figures 6A, B</xref>) demonstrate the changes in resonance behavior as the ssDNA thickness increases. For a baseline thickness of 3.2&#xa0;nm, the resonance dip is sharp and well-defined, with an attenuation of 6.99%. This reflects moderate plasmonic interaction and low optical losses. As the thickness increases, the resonance dip deepens significantly, with attenuation peaking at 94.27% for 50&#xa0;nm. Such high attenuation corresponds to excessive energy losses, reducing signal response and compromising biosensing performance. At 5&#xa0;nm, attenuation is still low at 8.56%, providing efficient plasmonic coupling without substantial optical losses.</p>
<fig id="F6" position="float">
<label>FIGURE 6</label>
<caption>
<p>
<bold>(A)</bold> SPR reflectance curves plotted as a function of the ssDNA thickness: ssDNA<sub>3.2nm_base</sub> in water (with the optimized Ag/S<sub>3</sub>N<sub>4</sub>/MoS<sub>2</sub> thickness and original parameters from <xref ref-type="sec" rid="s11">Supplementary Table S1</xref>) and ssDNA<sub>3.2nm</sub>&#x2013;ssDNA<sub>50nm</sub> in a PBS solution. <bold>(B)</bold> Percentage attenuation of reflectance at the resonance dip for each ssDNA layer. <bold>(C)</bold> Full Width at Half Maximum (FWHM) of the resonance curve. <bold>(D)</bold> Percentage enhancement in sensitivity across all thickness values, taking as the baseline, ssDNA<sub>3.2nm_base</sub>.</p>
</caption>
<graphic xlink:href="fnano-06-1505751-g006.tif"/>
</fig>
<p>The FWHM values (<xref ref-type="fig" rid="F6">Figure 6C</xref>) reflect how the resonance sharpness evolves with increasing ssDNA thickness. At 3.2&#xa0;nm, the FWHM is 6.76&#xb0;, representing high resolution and precise detection of resonance shifts. However, as the thickness increases, the FWHM broadens, reaching 19.11&#xb0; at 50&#xa0;nm. This loss of resolution reduces the sensor&#x2019;s ability to detect subtle refractive index changes. At 5&#xa0;nm, the FWHM increases slightly to 6.92&#xb0;, maintaining a strong balance between resolution and enhanced plasmonic interaction.</p>
<p>Sensitivity enhancement (<xref ref-type="fig" rid="F6">Figure 6D</xref>) shows a steady increase with thicker ssDNA layers, peaking at 6.90% for 20&#xa0;nm. At 5&#xa0;nm, the sensitivity enhancement is 2.06%, a noticeable improvement over the baseline thickness of 3.2&#xa0;nm. Beyond 5&#xa0;nm, the higher sensitivity values are counterbalanced by the rapid rise in attenuation and broadening of the FWHM. This trade-off limits the practical applicability of thicker ssDNA layers despite their higher sensitivity. Indeed, at a thickness of 5&#xa0;nm, the ssDNA layer provides a balance that minimizes energy losses, preserves adequate resolution, and ensures reliable sensitivity enhancement. This configuration avoids the excessive attenuation and reduced resolution associated with thicker layers while still offering improved biosensing capabilities.</p>
</sec>
<sec id="s3-6">
<title>3.6 Application of the optimized biosensor for virus sensing</title>
<p>To emphasize, <xref ref-type="sec" rid="s11">Supplementary Table S8</xref> presents the optimized parameters of Sys&#x2088; following the detailed analysis of each layer&#x2019;s thickness. These parameters, which include refractive index and thickness values, represent the final configuration of the SPR biosensor for effective detection of SARS-CoV-2 in PBS. The results also include the refractive index changes corresponding to different virus concentrations, based on experimental observations reported by <xref ref-type="bibr" rid="B13">Kumar et al. (2022)</xref>, who observed a linear relationship between virus concentration and refractive index.</p>
<p>Hence, the optimized configuration of Sys&#x2088; consists of a BK7 prism as the substrate, which has a refractive index of 1.5151. This serves as the base for the plasmonic structure. The Ag layer, with a thickness of 45&#xa0;nm, was selected for its superior balance of attenuation, FWHM, and sensitivity enhancement. The S&#x2083;N&#x2084; layer has an optimized thickness of 13&#xa0;nm, contributing to enhanced plasmon propagation and improved resonance behavior. The MoS<sub>2</sub> layer has a thickness of 0.65&#xa0;nm, corresponding to a monolayer. Its refractive index is 2.7611 &#x2b; 1.6987i, which ensures efficient light-matter interaction, further enhancing the system&#x2019;s sensitivity. The ssDNA layer, which could be functionalized for specific binding to SARS-CoV-2 RNA, has a thickness of 5&#xa0;nm and a refractive index of 1.462.</p>
<p>The PBS medium, with a refractive index of 1.334, serves as the surrounding environment for detecting the target analyte. We point out that the refractive index values of SARS-CoV-2 in PBS range from 1.340 for a virus concentration of 150&#xa0;mM to 1.355 for 525&#xa0;mM. However, the concentrations reported in the experimental study (<xref ref-type="bibr" rid="B13">Kumar et al., 2022</xref>), ranging from 150 to 525&#xa0;mM, are not representative of realistic physiological conditions, where virus concentrations are typically much lower. To address this limitation and enable the realistic testing of the proposed Sys&#x2088; biosensor, we extended the linear relationship to extrapolate the refractive index of SARS-CoV-2 in PBS for concentrations ranging from 0.01&#xa0;mM to 150&#xa0;mM (<xref ref-type="sec" rid="s11">Supplementary Table S9</xref>). This extrapolation allows us to simulate and evaluate the biosensor&#x2019;s performance under more plausible scenarios, providing a deeper understanding of its sensitivity and detection capability in practical applications.</p>
<p>We now move to the focus of the present work, say, the performance of the optimized Sys&#x2088; biosensor was evaluated across SARS-CoV-2 concentrations ranging from 0.01 to 150&#xa0;mM in PBS, as shown in <xref ref-type="fig" rid="F7">Figure 7</xref> and <xref ref-type="sec" rid="s11">Supplementary Table S9</xref>. At baseline (<email>PBS@0.0</email> mM), the SPR reflectance curve shows a shallow resonance dip, reflecting the absence of analyte interaction (<xref ref-type="fig" rid="F7">Figure 7A</xref>). As virus concentration increases, the resonance dip deepens progressively, with noticeable angular shifts at higher concentrations (50&#x2013;150&#xa0;mM). While the shifts at lower concentrations (0.01&#x2013;0.1&#xa0;mM) are minimal, the biosensor begins to demonstrate a measurable response starting at 1.0&#xa0;mM, where sensitivity enhancement reaches 0.01% (discussed below). This indicates the biosensor&#x2019;s capability to detect changes in refractive index at detectable levels while still being limited in resolving extremely dilute samples.</p>
<fig id="F7" position="float">
<label>FIGURE 7</label>
<caption>
<p>
<bold>(A)</bold> SPR reflectance curves plotted as a function of the virus concentration: <email>PBS@0.0</email> mM in water (with the optimized Ag/S<sub>3</sub>N<sub>4</sub>/MoS<sub>2</sub>/ssDNA thickness) and <email>PBS@0.01&#x2013;</email>; PBS@150&#xa0;mM in a PBS solution. <bold>(B)</bold> Percentage attenuation of reflectance at the resonance dip for each virus concentration. <bold>(C)</bold> Full Width at Half Maximum (FWHM) of the resonance curve. <bold>(D)</bold> Percentage enhancement in sensitivity across all thickness values, taking as the baseline, <email>PBS@0.0</email> mM.</p>
</caption>
<graphic xlink:href="fnano-06-1505751-g007.tif"/>
</fig>
<p>The attenuation values (<xref ref-type="fig" rid="F7">Figure 7B</xref>) highlight the sensor&#x2019;s performance in preserving signal response. At concentrations below 10&#xa0;mM, attenuation remains relatively low, ranging between 8.56% and 8.82%, which supports minimal optical losses and efficient plasmonic coupling. However, for higher concentrations such as 50&#xa0;mM and 150&#xa0;mM, attenuation increases substantially, reaching 14.06% at 150&#xa0;mM. This rise in attenuation reflects stronger plasmonic interaction with the analyte but introduces optical losses that may impact precision at elevated analyte concentrations.</p>
<p>The FWHM (<xref ref-type="fig" rid="F7">Figure 7C</xref>) remains consistent across lower concentrations, ranging between 6.97&#xb0; and 6.99&#xb0; up to 10&#xa0;mM. This stability highlights the sensor&#x2019;s ability to maintain resolution for detecting subtle refractive index changes. At higher concentrations, such as 150&#xa0;mM, the FWHM broadens slightly to 7.23&#xb0;, indicating a gradual decline in resolution. While the broadening is not drastic, it points to the inherent trade-off between sensitivity and resolution as analyte concentrations increase.</p>
<p>The sensitivity enhancement (<xref ref-type="fig" rid="F7">Figure 7D</xref>) further reinforces the biosensor&#x2019;s behavior at varying concentrations. At the lowest concentrations (0.01 and 0.1&#xa0;mM), sensitivity enhancement remains negligible. The biosensor begins to exhibit measurable sensitivity at 1.0&#xa0;mM, with an enhancement of 0.01%. As the virus concentration increases, the sensitivity improves significantly, reaching 1.92% at 150&#xa0;mM. This trend highlights the biosensor&#x2019;s effectiveness in detecting moderate to high concentrations of the virus, although the minimal enhancement at very low concentrations indicates limitations in resolving trace amounts of the target analyte.</p>
<p>The Sys&#x2088; biosensor offers several strengths, including low attenuation and consistent FWHM at lower concentrations, which ensure efficient plasmonic coupling and high resolution. The measurable sensitivity response beginning at 1.0&#xa0;mM and its significant improvement at higher concentrations confirm its utility for detecting moderate to elevated virus levels. However, the limited sensitivity enhancement at concentrations below 1.0&#xa0;mM and the increased attenuation at higher concentrations highlight areas for potential refinement.</p>
</sec>
<sec id="s3-7">
<title>3.7 Metrics analysis: part 1</title>
<p>Here, the performance evaluation of the optimized Sys&#x2088; biosensor focuses on angular shift (&#x394;&#x3b8;), sensitivity to refractive index changes (S), detection accuracy (DA), and quality factor (QF). These metrics, presented in <xref ref-type="fig" rid="F8">Figure 8</xref> and <xref ref-type="sec" rid="s11">Supplementary Table S10</xref>, provide a detailed understanding of how the biosensor responds to varying concentrations of SARS-CoV-2, ranging from 0.01 to 150&#xa0;mM. The angular shift, shown in <xref ref-type="fig" rid="F8">Figure 8A</xref>, measures the resonance angle change caused by variations in the refractive index due to the presence of the virus. At very low concentrations (0.01 and 0.1&#xa0;mM), the &#x394;&#x3b8; is negligible, indicating limited interaction between the sensor and the analyte at these levels. However, starting at 1.0&#xa0;mM, the biosensor begins to exhibit a measurable angular shift, with &#x394;&#x3b8; reaching 0.01&#xb0;. As the concentration increases to 150&#xa0;mM, the angular shift rises significantly to 1.57&#xb0;. This increasing trend demonstrates the biosensor&#x2019;s capability to effectively detect higher concentrations, although its limited response at lower concentrations highlights the challenge of detecting trace amounts of the virus.</p>
<fig id="F8" position="float">
<label>FIGURE 8</label>
<caption>
<p>Performance metrics of the optimized biosensor evaluated across varying virus concentrations: <bold>(A)</bold> Angular shift, <bold>(B)</bold> Sensitivity to refractive index variations, <bold>(C)</bold> Detection Accuracy (DA), and <bold>(D)</bold> Quality Factor (QF).</p>
</caption>
<graphic xlink:href="fnano-06-1505751-g008.tif"/>
</fig>
<p>The sensitivity, quantified in <xref ref-type="fig" rid="F8">Figure 8B</xref>, reflects the angular shift per refractive index unit (<inline-formula id="inf31">
<mml:math id="m45">
<mml:mrow>
<mml:mo>&#xb0;</mml:mo>
</mml:mrow>
</mml:math>
</inline-formula>/RIU) and highlights the biosensor&#x2019;s responsiveness to refractive index changes. For concentrations below 1.0&#xa0;mM, sensitivity remains at 0.0&#xb0;/RIU due to the negligible &#x394;&#x3b8; values. At 1.0&#xa0;mM, sensitivity increases sharply to 200&#xb0;/RIU, demonstrating the biosensor&#x2019;s capacity to respond to detectable refractive index variations. As the concentration rises to 150&#xa0;mM, sensitivity improves further, reaching 261.33&#xb0;/RIU. These results emphasize the biosensor&#x2019;s strong performance for moderate to high concentrations while also underlining its reduced effectiveness for detecting very low concentrations where refractive index variations are minimal.</p>
<p>The detection accuracy, as shown in <xref ref-type="fig" rid="F8">Figure 8C</xref>, is a measure of the precision of the biosensor in detecting angular shifts. For virus concentrations below 1.0&#xa0;mM, the DA remains negligible due to the absence of measurable angular shifts. At 1.0&#xa0;mM, the DA improves to 0.001, increasing progressively to 0.217&#xa0;at 150&#xa0;mM. This trend confirms the biosensor&#x2019;s reliability in detecting moderate to high analyte levels while indicating the need for enhancements to improve accuracy at very low concentrations.</p>
<p>The quality factor, displayed in <xref ref-type="fig" rid="F8">Figure 8D</xref>, evaluates the efficiency of the biosensor by combining sensitivity and resolution. For concentrations below 1.0&#xa0;mM, the QF is negligible, consistent with the zero angular shifts and sensitivity observed at these levels. At 1.0&#xa0;mM, the QF reaches 28.68 RIU<sup>&#x2212;1</sup>, and it increases steadily with higher concentrations, peaking at 36.16 RIU<sup>&#x2212;1</sup> for 150&#xa0;mM. The consistent improvement in QF with rising concentrations demonstrates the biosensor&#x2019;s robustness for detecting substantial analyte levels, where the combination of high sensitivity and reasonable resolution enhances its total effectiveness.</p>
<p>The results collectively show that the Sys&#x2088; biosensor performs well for moderate to elevated virus concentrations, demonstrating measurable angular shifts, high sensitivity, improved detection accuracy, and strong quality factors. However, its limited response at very low concentrations (0.01&#x2013;0.1&#xa0;mM) highlights a challenge in detecting trace amounts of the analyte, which is critical for early diagnostic applications. Addressing this limitation would significantly enhance the sensor&#x2019;s applicability for realistic scenarios where low analyte concentrations are common.</p>
</sec>
<sec id="s3-8">
<title>3.8 Metrics analysis: part 2</title>
<p>The performance of the optimized Sys&#x2088; biosensor is further analyzed through the metrics of Figure of Merit (FoM), Limit of Detection (LoD), and Signal-to-Noise Ratio (SNR), as presented in <xref ref-type="fig" rid="F9">Figure 9</xref> and <xref ref-type="sec" rid="s11">Supplementary Table S11</xref>. The FoM, shown in <xref ref-type="fig" rid="F9">Figure 9A</xref>, captures the efficiency of the biosensor by combining sensitivity and resolution into a single metric. For the lowest concentrations (0.01 and 0.1&#xa0;mM), the FoM remains at 0.0 RIU<sup>&#x2212;1</sup>, reflecting the negligible angular shifts and sensitivity observed at these levels. The FoM rises significantly at 1.0&#xa0;mM, reaching 333.97 RIU<sup>&#x2212;1</sup>, marking a clear improvement in the biosensor&#x2019;s ability to detect measurable refractive index changes. The performance peaks at 10&#xa0;mM, where the FoM attains its maximum value of 405.50 RIU<sup>&#x2212;1</sup>, indicating the optimal balance between sensitivity and resolution. However, at higher concentrations, such as 150&#xa0;mM, the FoM decreases to 257.23 RIU<sup>&#x2212;1</sup>, suggesting that optical losses and broader resonance peaks at elevated analyte levels begin to affect the sensor&#x2019;s efficiency.</p>
<fig id="F9" position="float">
<label>FIGURE 9</label>
<caption>
<p>Performance metrics of the optimized biosensor evaluated across varying virus concentrations: <bold>(A)</bold> Figure of Merit (FoM), <bold>(B)</bold> Limit of Detection (LoD), and <bold>(C)</bold> Signal-to-Noise Ratio (SNR).</p>
</caption>
<graphic xlink:href="fnano-06-1505751-g009.tif"/>
</fig>
<p>The LoD, reported in <xref ref-type="fig" rid="F9">Figure 9B</xref>, highlights the biosensor&#x2019;s ability to detect minimal analyte concentrations. At 1.0&#xa0;mM, the LoD is 2.50 &#xd7; 10<sup>&#x2212;5</sup>, demonstrating the biosensor&#x2019;s capability to detect low concentrations with reasonable precision. As the virus concentration increases, the LoD improves steadily, reaching 1.91 &#xd7; 10<sup>&#x2212;5</sup>&#xa0;at 150&#xa0;mM. This consistent trend reflects the sensor&#x2019;s capacity to detect higher analyte levels with increasing accuracy. However, for concentrations below 1.0&#xa0;mM, the LoD remains unresponsive, which accentuates a challenge in achieving reliable detection at trace analyte levels critical for early-stage diagnostics.</p>
<p>The SNR, presented in <xref ref-type="fig" rid="F9">Figure 9C</xref>, evaluates the biosensor&#x2019;s signal reliability relative to background noise. At very low concentrations (0.01 and 0.1&#xa0;mM), the SNR is negligible (0.0) due to zero angular shifts and weak sensitivity responses. The SNR begins to rise at 1.0&#xa0;mM, reaching 0.001, and increases progressively with higher concentrations. At 50&#xa0;mM, the SNR improves to 0.072, and it peaks at 0.217 for 150&#xa0;mM. This progression demonstrates the biosensor&#x2019;s ability to produce a more distinguishable and reliable signal as analyte levels increase, but it also highlights its limited performance at very low concentrations where the signal remains indistinguishable from noise.</p>
<p>These results collectively indicate that the Sys&#x2088; biosensor performs remarkably well at moderate to high SARS-CoV-2 concentrations. The high FoM at 10&#xa0;mM highlights the biosensor&#x2019;s efficiency in balancing sensitivity and resolution, while the steady improvements in LoD and SNR with increasing concentrations validate its reliability for detecting clinically relevant analyte levels.</p>
</sec>
</sec>
<sec sec-type="conclusion" id="s4">
<title>4 Conclusion</title>
<p>In summary, we developed and optimized a MoS&#x2082;-based SPR biosensor for SARS-CoV-2 detection, employing a multilayer structure comprising a BK7 prism, Ag film, S&#x2083;N&#x2084;, MoS&#x2082; monolayer, and a functionalized ssDNA layer. The numerical analysis was performed using the transfer matrix method (TMM), enabling a systematic optimization of the sensor configuration by adjusting layer thicknesses and material properties to maximize sensitivity, resolution, and efficiency.</p>
<p>The optimized sensor (Sys&#x2088;) features an Ag layer (45&#xa0;nm), S&#x2083;N&#x2084; layer (13&#xa0;nm), MoS&#x2082; monolayer (0.65&#xa0;nm), and ssDNA layer (5&#xa0;nm). The performance was evaluated across SARS-CoV-2 concentrations ranging from 0.01 to 150&#xa0;mM. Key metrics such as angular shift, sensitivity, detection accuracy, quality factor, figure of merit, limit of detection, and signal-to-noise ratio were analyzed. The sensor achieved a sensitivity of 261.33&#xb0;/RIU, a quality factor of 36.16 RIU<sup>&#x2212;1</sup>, and a low limit of detection of 1.91 &#xd7; 10<sup>&#x2212;5</sup>. An optimal figure of merit of 405.50 RIU<sup>&#x2212;1</sup> was observed at 10&#xa0;mM, highlighting the strong diagnostic potential for moderate analyte levels. Hence, this study demonstrates the effectiveness of the MoS&#x2082;-based SPR biosensor as a reliable platform for SARS-CoV-2 detection, leveraging advanced material properties and numerical modeling. While the sensor exhibited strong performance at moderate to high concentrations, further optimization is needed to enhance its sensitivity for trace analyte detection. These findings provide a foundation for future advancements in SPR biosensors for infectious disease diagnostics.</p>
</sec>
</body>
<back>
<sec sec-type="data-availability" id="s5">
<title>Data availability statement</title>
<p>The original contributions presented in the study are included in the article/<xref ref-type="sec" rid="s11">Supplementary Material</xref>, further inquiries can be directed to the corresponding author.</p>
</sec>
<sec sec-type="author-contributions" id="s6">
<title>Author contributions</title>
<p>TT: Conceptualization, Data curation, Formal Analysis, Funding acquisition, Investigation, Methodology, Project administration, Resources, Software, Supervision, Validation, Visualization, Writing&#x2013;original draft, Writing&#x2013;review and editing. GT-U: Conceptualization, Data curation, Formal Analysis, Funding acquisition, Investigation, Methodology, Project administration, Resources, Software, Supervision, Validation, Visualization, Writing&#x2013;original draft, Writing&#x2013;review and editing. KG: Conceptualization, Data curation, Formal Analysis, Funding acquisition, Investigation, Methodology, Project administration, Resources, Software, Supervision, Validation, Visualization, Writing&#x2013;original draft, Writing&#x2013;review and editing. MM: Conceptualization, Data curation, Formal Analysis, Funding acquisition, Investigation, Methodology, Project administration, Resources, Software, Supervision, Validation, Visualization, Writing&#x2013;original draft, Writing&#x2013;review and editing. CG: Conceptualization, Data curation, Formal Analysis, Funding acquisition, Investigation, Methodology, Project administration, Resources, Software, Supervision, Validation, Visualization, Writing&#x2013;original draft, Writing&#x2013;review and editing.</p>
</sec>
<sec sec-type="funding-information" id="s7">
<title>Funding</title>
<p>The author(s) declare that financial support was received for the research, authorship, and/or publication of this article. This work was funded and supported by Universidad T&#xe9;cnica Particular de Loja under grant No: POA_VIN-56. This work was partially supported by LNF-INFN: Progetto HPSWFOOD Regione Lazio-CUP I35F20000400005.</p>
</sec>
<ack>
<p>GT-U, wishes to thank Escuela Superior Polit&#xe9;cnica de Chimborazo for their hospitality during the completion of this work.</p>
</ack>
<sec sec-type="COI-statement" id="s8">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec sec-type="ai-statement" id="s10">
<title>Generative AI statement</title>
<p>The author(s) declare that no Generative AI was used in the creation of this manuscript.</p>
</sec>
<sec sec-type="disclaimer" id="s9">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<sec id="s11">
<title>Supplementary material</title>
<p>The Supplementary Material for this article can be found online at: <ext-link ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/fnano.2024.1505751/full#supplementary-material">https://www.frontiersin.org/articles/10.3389/fnano.2024.1505751/full&#x23;supplementary-material</ext-link>
</p>
<supplementary-material xlink:href="Table1.docx" id="SM1" mimetype="application/docx" xmlns:xlink="http://www.w3.org/1999/xlink"/>
</sec>
<ref-list>
<title>References</title>
<ref id="B1">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Akib</surname>
<given-names>T. B. A.</given-names>
</name>
<name>
<surname>Mou</surname>
<given-names>S. F.</given-names>
</name>
<name>
<surname>Rahman</surname>
<given-names>M. M.</given-names>
</name>
<name>
<surname>Rana</surname>
<given-names>M. M.</given-names>
</name>
<name>
<surname>Islam</surname>
<given-names>M. R.</given-names>
</name>
<name>
<surname>Mehedi</surname>
<given-names>I. M.</given-names>
</name>
<etal/>
</person-group> (<year>2021</year>). <article-title>Design and numerical analysis of a graphene-coated SPR biosensor for rapid detection of the novel coronavirus</article-title>. <source>Sensors (Basel).</source> <volume>21</volume>, <fpage>3491</fpage>. <pub-id pub-id-type="doi">10.3390/s21103491</pub-id>
</citation>
</ref>
<ref id="B2">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Akib</surname>
<given-names>T. B. A.</given-names>
</name>
<name>
<surname>Rana</surname>
<given-names>M. M.</given-names>
</name>
<name>
<surname>Mehedi</surname>
<given-names>I. M.</given-names>
</name>
</person-group> (<year>2024</year>). <article-title>Multi-layer SPR biosensor for in-situ amplified monitoring of the SARS-CoV-2 omicron (B.1.1.529) variant</article-title>. <source>Biosens. Bioelectron. X</source> <volume>16</volume>, <fpage>100434</fpage>. <pub-id pub-id-type="doi">10.1016/j.biosx.2023.100434</pub-id>
</citation>
</ref>
<ref id="B3">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cai</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Wu</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>X.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Performance enhancement of SPR biosensor using graphene&#x2013;MoS<sub>2,</sub> hybrid structure</article-title>. <source>Nanomater. (Basel).</source> <volume>12</volume>, <fpage>2219</fpage>. <pub-id pub-id-type="doi">10.3390/nano12132219</pub-id>
</citation>
</ref>
<ref id="B4">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cerutti</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Burdino</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Milia</surname>
<given-names>M. G.</given-names>
</name>
<name>
<surname>Allice</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Gregori</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Bruzzone</surname>
<given-names>B.</given-names>
</name>
<etal/>
</person-group> (<year>2020</year>). <article-title>Urgent need of rapid tests for SARS-CoV-2 antigen detection: evaluation of the SD-biosensor antigen test for SARS-CoV-2</article-title>. <source>J. Clin. Virol.</source> <volume>132</volume>, <fpage>104654</fpage>. <pub-id pub-id-type="doi">10.1016/j.jcv.2020.104654</pub-id>
</citation>
</ref>
<ref id="B5">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Drobysh</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Liustrovaite</surname>
<given-names>V.</given-names>
</name>
<name>
<surname>Kanetski</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>BrasIunas</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Zvirbliene</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Rimkute</surname>
<given-names>A.</given-names>
</name>
<etal/>
</person-group> (<year>2024</year>). <article-title>Electrochemical biosensing based comparative study of monoclonal antibodies against SARS-CoV-2 nucleocapsid protein</article-title>. <source>Sci. Total Environ.</source> <volume>908</volume>, <fpage>168154</fpage>. <pub-id pub-id-type="doi">10.1016/j.scitotenv.2023.168154</pub-id>
</citation>
</ref>
<ref id="B6">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Erkihun</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Ayele</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Asmare</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Endalamaw</surname>
<given-names>K.</given-names>
</name>
</person-group> (<year>2024</year>). <article-title>Current updates on variants of SARS-CoV-2: systematic review</article-title>. <source>Health Sci. Rep.</source> <volume>7</volume>, <fpage>e70166</fpage>. <pub-id pub-id-type="doi">10.1002/hsr2.70166</pub-id>
</citation>
</ref>
<ref id="B7">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ghodrati</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Mir</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Farmani</surname>
<given-names>A.</given-names>
</name>
</person-group> (<year>2024</year>). <article-title>Sensitivity enhancement of the surface plasmon resonance biosensor based on hybrid structure using MXene and MoS2 for refractive index sensing: an angular interrogation approach</article-title>. <source>Sens. Imaging</source> <volume>25</volume>, <fpage>39</fpage>. <pub-id pub-id-type="doi">10.1007/s11220-024-00491-4</pub-id>
</citation>
</ref>
<ref id="B8">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Haque</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Rouf</surname>
<given-names>H. K.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>DNA hybridization detection using graphene-MoSe2&#x2013;Ag heterostructure-based surface plasmon resonance biosensor</article-title>. <source>Appl. Phys. A</source> <volume>127</volume> (<issue>10</issue>), <fpage>759</fpage>. <pub-id pub-id-type="doi">10.1007/s00339-021-04888-w</pub-id>
</citation>
</ref>
<ref id="B9">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hu</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Huang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Hu</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Wu</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>High-sensitivity multi-channel refractive-index sensor based on a graphene-based hybrid tamm plasmonic structure</article-title>. <source>Opt. Mat. Express</source> <volume>11</volume> (<issue>11</issue>), <fpage>3833</fpage>&#x2013;<lpage>3843</lpage>. <pub-id pub-id-type="doi">10.1364/OME.440987</pub-id>
</citation>
</ref>
<ref id="B10">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Huggett</surname>
<given-names>J. F.</given-names>
</name>
<name>
<surname>Moran-Gilad</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>J. E.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>COVID-19 new diagnostics development: novel detection methods for SARS-CoV-2 infection and considerations for their translation to routine use</article-title>. <source>Curr. Opin. Pulm. Med.</source> <volume>27</volume>, <fpage>155</fpage>&#x2013;<lpage>162</lpage>. <pub-id pub-id-type="doi">10.1097/MCP.0000000000000768</pub-id>
</citation>
</ref>
<ref id="B11">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Iravani</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Nano- and biosensors for the detection of SARS-CoV-2: challenges and opportunities</article-title>. <source>Mat. Adv.</source> <volume>1</volume>, <fpage>3092</fpage>&#x2013;<lpage>3103</lpage>. <pub-id pub-id-type="doi">10.1039/D0MA00702A</pub-id>
</citation>
</ref>
<ref id="B12">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Justino</surname>
<given-names>C. I. L.</given-names>
</name>
<name>
<surname>Freitas</surname>
<given-names>A. C.</given-names>
</name>
<name>
<surname>Pereira</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Duarte</surname>
<given-names>A. C.</given-names>
</name>
<name>
<surname>Rocha-Santos</surname>
<given-names>T. A. P.</given-names>
</name>
</person-group> <year>2015</year>, <article-title>Recent developments in recognition elements for chemical sensors and biosensors</article-title>. <source>TrAC, Trends Anal. Chem</source>, <volume>68</volume>, <fpage>2</fpage>&#x2013;<lpage>17</lpage>. <pub-id pub-id-type="doi">10.1016/j.trac.2015.03.006</pub-id>
</citation>
</ref>
<ref id="B13">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kumar</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Kumar</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Srivastava</surname>
<given-names>S. K.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Silicon nitride-BP-based surface plasmon resonance highly sensitive biosensor for virus SARS-CoV-2 detection</article-title>. <source>Plasmonics</source> <volume>17</volume> (<issue>3</issue>), <fpage>1065</fpage>&#x2013;<lpage>1077</lpage>. <pub-id pub-id-type="doi">10.1007/s11468-021-01589-1</pub-id>
</citation>
</ref>
<ref id="B14">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Li</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Zhu</surname>
<given-names>H.</given-names>
</name>
</person-group> (<year>2015</year>), <article-title>Two-dimensional MoS2: properties, preparation, and applications</article-title>. <source>J. Mater</source>, <volume>1</volume>, <fpage>33</fpage>&#x2013;<lpage>44</lpage>. <pub-id pub-id-type="doi">10.1016/j.jmat.2015.03.003</pub-id>
</citation>
</ref>
<ref id="B15">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Liu</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Hang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Bao</surname>
<given-names>N.</given-names>
</name>
<etal/>
</person-group> (<year>2024</year>). <article-title>Rapid assays of SARS-CoV-2 virus and noble biosensors by nanomaterials</article-title>. <source>Nano Converg.</source> <volume>11</volume>, <fpage>2</fpage>. <pub-id pub-id-type="doi">10.1186/s40580-023-00408-z</pub-id>
</citation>
</ref>
<ref id="B16">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Luke</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Okawachi</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Lamont</surname>
<given-names>M. R. E.</given-names>
</name>
<name>
<surname>Gaeta</surname>
<given-names>A. L.</given-names>
</name>
<name>
<surname>Lipson</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>Broadband mid-infrared frequency comb generation in a Si_3N_4 microresonator</article-title>. <source>Opt. Lett.</source> <volume>40</volume> (<issue>21</issue>), <fpage>4823</fpage>&#x2013;<lpage>4826</lpage>. <pub-id pub-id-type="doi">10.1364/OL.40.004823</pub-id>
</citation>
</ref>
<ref id="B17">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mudgal</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Saharia</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Choure</surname>
<given-names>K. K.</given-names>
</name>
<name>
<surname>Agarwal</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Singh</surname>
<given-names>G.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Sensitivity enhancement with anti-reflection coating of silicon nitride (Si3N4) layer in silver-based Surface Plasmon Resonance (SPR) sensor for sensing of DNA hybridization</article-title>. <source>Appl. Phys. A</source> <volume>126</volume> (<issue>12</issue>), <fpage>946</fpage>. <pub-id pub-id-type="doi">10.1007/s00339-020-04126-9</pub-id>
</citation>
</ref>
<ref id="B18">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Naik</surname>
<given-names>G. V.</given-names>
</name>
<name>
<surname>Shalaev</surname>
<given-names>V. M.</given-names>
</name>
<name>
<surname>Boltasseva</surname>
<given-names>A.</given-names>
</name>
</person-group> (<year>2013</year>). <article-title>Alternative plasmonic materials: beyond gold and silver</article-title>. <source>Adv. Mat.</source> <volume>25</volume> (<issue>24</issue>), <fpage>3264</fpage>&#x2013;<lpage>3294</lpage>. <pub-id pub-id-type="doi">10.1002/adma.201205076</pub-id>
</citation>
</ref>
<ref id="B19">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Patel</surname>
<given-names>S. K.</given-names>
</name>
<name>
<surname>Parmar</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2021</year>), <article-title>Highly sensitive and tunable refractive index biosensor based on phase change material</article-title>. <source>Physica B: Condensed Matter</source>, <volume>622</volume>, <fpage>413357</fpage>. <pub-id pub-id-type="doi">10.1016/j.physb.2021.413357</pub-id>
</citation>
</ref>
<ref id="B20">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pisarra</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Vacacela Gomez</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Sindona</surname>
<given-names>A.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Massive and massless plasmons in germanene nanosheets</article-title>. <source>Sci. Rep.</source> <volume>12</volume>, <fpage>18624</fpage>. <pub-id pub-id-type="doi">10.1038/s41598-022-23058-3</pub-id>
</citation>
</ref>
<ref id="B21">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sajal</surname>
<given-names>S. S. A.</given-names>
</name>
<name>
<surname>Islam</surname>
<given-names>D. Z.</given-names>
</name>
<name>
<surname>Khandker</surname>
<given-names>S. S.</given-names>
</name>
<name>
<surname>Sol&#xf3;rzano-Ortiz</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Fardoun</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Ahmed</surname>
<given-names>M. F.</given-names>
</name>
<etal/>
</person-group> (<year>2024</year>), <article-title>Strategies to overcome erroneous outcomes in reverse transcription-polymerase chain reaction (RT-PCR) testing: insights from the COVID-19 pandemic</article-title>. <source>Cureus</source>, <volume>16</volume>, <fpage>e72954</fpage>. <pub-id pub-id-type="doi">10.7759/cureus.72954</pub-id>
</citation>
</ref>
<ref id="B22">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sengupta</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Hussain</surname>
<given-names>C. M.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Graphene-based field-effect transistor biosensors for the rapid detection and analysis of viruses: a perspective in view of COVID-19</article-title>. <source>Carbon Trends</source> <volume>2</volume>, <fpage>100011</fpage>. <pub-id pub-id-type="doi">10.1016/j.cartre.2020.100011</pub-id>
</citation>
</ref>
<ref id="B23">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sindona</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Pisarra</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Bellucci</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Tene</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Guevara</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Vacacela Gomez</surname>
<given-names>C.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Plasmon oscillations in two-dimensional arrays of ultranarrow graphene nanoribbons</article-title>. <source>Phys. Rev. B</source> <volume>100</volume> (<issue>23</issue>), <fpage>235422</fpage>. <pub-id pub-id-type="doi">10.1103/PhysRevB.100.235422</pub-id>
</citation>
</ref>
<ref id="B24">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Srivastava</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Verma</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Das</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Prajapati</surname>
<given-names>Y. K.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>A theoretical approach to improve the performance of SPR biosensor using MXene and black phosphorus</article-title>. <source>Opt. (Stuttg).</source> <volume>203</volume>, <fpage>163430</fpage>. <pub-id pub-id-type="doi">10.1016/j.ijleo.2019.163430</pub-id>
</citation>
</ref>
<ref id="B25">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Su</surname>
<given-names>L.-C.</given-names>
</name>
<name>
<surname>Tian</surname>
<given-names>Y.-C.</given-names>
</name>
<name>
<surname>Chang</surname>
<given-names>Y.-F.</given-names>
</name>
<name>
<surname>Chou</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Lai</surname>
<given-names>C.-S.</given-names>
</name>
</person-group> (<year>2013</year>). <article-title>Rapid detection of urinary polyomavirus BK by heterodyne-based surface plasmon resonance biosensor</article-title>. <source>J. Biomed. Opt.</source> <volume>19</volume> (<issue>1</issue>), <fpage>011013</fpage>. <pub-id pub-id-type="doi">10.1117/1.JBO.19.1.011013</pub-id>
</citation>
</ref>
<ref id="B26">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tene</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Arias Arias</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Paredes-P&#xe1;liz</surname>
<given-names>K. I.</given-names>
</name>
<name>
<surname>Haro-Barroso</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Vacacela Gomez</surname>
<given-names>C.</given-names>
</name>
</person-group> (<year>2024b</year>). <article-title>An optimized graphene-based surface plasmon resonance biosensor for detecting SARS-CoV-2</article-title>. <source>Appl. Sci. (Basel).</source> <volume>14</volume>, <fpage>10724</fpage>. <pub-id pub-id-type="doi">10.3390/app142210724</pub-id>
</citation>
</ref>
<ref id="B27">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tene</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Bellucci</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Arias Arias</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Carrera Almendariz</surname>
<given-names>L. S.</given-names>
</name>
<name>
<surname>Flores Huilcapi</surname>
<given-names>A. G.</given-names>
</name>
<name>
<surname>Vacacela Gomez</surname>
<given-names>C.</given-names>
</name>
</person-group> (<year>2024a</year>). <article-title>Role of graphene in surface plasmon resonance-based biosensors</article-title>. <source>Sensors (Basel).</source> <volume>24</volume>, <fpage>4670</fpage>. <pub-id pub-id-type="doi">10.3390/s24144670</pub-id>
</citation>
</ref>
<ref id="B28">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tene</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Guevara</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Benalc&#xe1;zar Palacios</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Morocho Barrionuevo</surname>
<given-names>T. P.</given-names>
</name>
<name>
<surname>Vacacela Gomez</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Bellucci</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2023b</year>). <article-title>Optical properties of graphene oxide</article-title>. <source>Front. Chem.</source> <volume>11</volume>, <fpage>1214072</fpage>. <pub-id pub-id-type="doi">10.3389/fchem.2023.1214072</pub-id>
</citation>
</ref>
<ref id="B29">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tene</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Guevara</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Moreano</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Calder&#xf3;n</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Bonilla Garc&#xed;a</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Vaccalea Gomez</surname>
<given-names>C.</given-names>
</name>
<etal/>
</person-group> (<year>2023a</year>). <article-title>Modeling plasmonics and electronics in semiconducting graphene nanostrips</article-title>. <source>Emerg. Sci. J.</source> <volume>7</volume> (<issue>5</issue>), <fpage>1459</fpage>&#x2013;<lpage>1477</lpage>. <pub-id pub-id-type="doi">10.28991/ESJ-2023-07-05-01</pub-id>
</citation>
</ref>
<ref id="B30">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tene</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Svozil&#xed;k</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Colcha</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Cevallos</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Vinueza-Naranjo</surname>
<given-names>P. G.</given-names>
</name>
<name>
<surname>Vacacela Gomez</surname>
<given-names>C.</given-names>
</name>
<etal/>
</person-group> (<year>2024c</year>). <article-title>The tunable parameters of graphene-based biosensors</article-title>. <source>Sensors (Basel).</source> <volume>24</volume>, <fpage>5049</fpage>. <pub-id pub-id-type="doi">10.3390/s24155049</pub-id>
</citation>
</ref>
<ref id="B31">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Uddin</surname>
<given-names>S. M. A.</given-names>
</name>
<name>
<surname>Chowdhury</surname>
<given-names>S. S.</given-names>
</name>
<name>
<surname>Kabir</surname>
<given-names>E.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Numerical analysis of a highly sensitive surface plasmon resonance sensor for SARS-CoV-2 detection</article-title>. <source>Plasmonics</source> <volume>16</volume> (<issue>6</issue>), <fpage>2025</fpage>&#x2013;<lpage>2037</lpage>. <pub-id pub-id-type="doi">10.1007/s11468-021-01455-0</pub-id>
</citation>
</ref>
<ref id="B32">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Varasteanu</surname>
<given-names>P.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Transition metal dichalcogenides/gold-based surface plasmon resonance sensors: exploring the geometrical and material parameters</article-title>. <source>Plasmonics</source> <volume>15</volume> (<issue>1</issue>), <fpage>243</fpage>&#x2013;<lpage>253</lpage>. <pub-id pub-id-type="doi">10.1007/s11468-019-01033-5</pub-id>
</citation>
</ref>
<ref id="B33">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yang</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Zhou</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Geng</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Cheng</surname>
<given-names>X.</given-names>
</name>
</person-group> (<year>2024</year>), <article-title>The coronavirus is a formidable foe: children&#x2019;s multimodal articulations of SARS-CoV-2 virus and COVID-19 pandemic experiences in China</article-title>. <source>Psychology. Health</source>, <fpage>1</fpage>, <lpage>33</lpage>. <pub-id pub-id-type="doi">10.1080/08870446.2024.2414797</pub-id>
</citation>
</ref>
<ref id="B34">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zheng</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Xu</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Pan</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Sun</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>Q.</given-names>
</name>
</person-group> (<year>2024</year>). <article-title>Angle sensor for minimally invasive surgical robot based on surface plasmon resonance with Kretschmann prisms</article-title>. <source>Plasmonics</source> (<issue>5</issue>), <fpage>1</fpage>&#x2013;<lpage>10</lpage>. <pub-id pub-id-type="doi">10.1007/s11468-024-02471-6</pub-id>
</citation>
</ref>
<ref id="B35">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhu</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Jiang</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Jouha</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>Q.</given-names>
</name>
<name>
<surname>Wu</surname>
<given-names>L.</given-names>
</name>
<etal/>
</person-group> (<year>2024</year>), <article-title>A post-pandemic perspective: evolution of SARS-CoV-2 early detection</article-title>, <source>TrAC. Trends Anal. Chem</source>, <volume>170</volume>, <fpage>117458</fpage>. <pub-id pub-id-type="doi">10.1016/j.trac.2023.117458</pub-id>
</citation>
</ref>
</ref-list>
</back>
</article>