<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3-mathml3.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:ali="http://www.niso.org/schemas/ali/1.0/" article-type="review-article" dtd-version="1.3" xml:lang="EN">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Med.</journal-id>
<journal-title-group>
<journal-title>Frontiers in Medicine</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Med.</abbrev-journal-title>
</journal-title-group>
<issn pub-type="epub">2296-858X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fmed.2025.1662020</article-id>
<article-version article-version-type="Version of Record" vocab="NISO-RP-8-2008"/>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Review</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Recent advances in radionuclide medical imaging techniques</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author"><name><surname>Xu</surname> <given-names>Shuyu</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="conceptualization" vocab-term-identifier="https://credit.niso.org/contributor-roles/conceptualization/">Conceptualization</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Formal analysis" vocab-term-identifier="https://credit.niso.org/contributor-roles/formal-analysis/">Formal analysis</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="investigation" vocab-term-identifier="https://credit.niso.org/contributor-roles/investigation/">Investigation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; original draft" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-original-draft/">Writing &#x2013; original draft</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Data curation" vocab-term-identifier="https://credit.niso.org/contributor-roles/data-curation/">Data curation</role>
</contrib>
<contrib contrib-type="author"><name><surname>Liu</surname> <given-names>Ge</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/3126125"/>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Formal analysis" vocab-term-identifier="https://credit.niso.org/contributor-roles/formal-analysis/">Formal analysis</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="investigation" vocab-term-identifier="https://credit.niso.org/contributor-roles/investigation/">Investigation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="visualization" vocab-term-identifier="https://credit.niso.org/contributor-roles/visualization/">Visualization</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &#x0026; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-review-editing/">Writing &#x2013; review &#x0026; editing</role>
</contrib>
<contrib contrib-type="author" corresp="yes"><name><surname>Wei</surname> <given-names>Qingyang</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="c001"><sup>&#x002A;</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/2177791"/>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Project administration" vocab-term-identifier="https://credit.niso.org/contributor-roles/project-administration/">Project administration</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="supervision" vocab-term-identifier="https://credit.niso.org/contributor-roles/supervision/">Supervision</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &#x0026; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-review-editing/">Writing &#x2013; review &#x0026; editing</role>
</contrib>
<contrib contrib-type="author"><name><surname>Liu</surname> <given-names>Hui</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="supervision" vocab-term-identifier="https://credit.niso.org/contributor-roles/supervision/">Supervision</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &#x0026; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-review-editing/">Writing &#x2013; review &#x0026; editing</role>
</contrib>
<contrib contrib-type="author"><name><surname>Wu</surname> <given-names>Jing</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/1697487"/>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="supervision" vocab-term-identifier="https://credit.niso.org/contributor-roles/supervision/">Supervision</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &#x0026; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-review-editing/">Writing &#x2013; review &#x0026; editing</role>
</contrib>
<contrib contrib-type="author" corresp="yes"><name><surname>Liu</surname> <given-names>Yaqiang</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref><xref ref-type="corresp" rid="c001"><sup>&#x002A;</sup></xref>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Project administration" vocab-term-identifier="https://credit.niso.org/contributor-roles/project-administration/">Project administration</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &#x0026; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-review-editing/">Writing &#x2013; review &#x0026; editing</role>
</contrib>
<contrib contrib-type="author" corresp="yes"><name><surname>He</surname> <given-names>Zuo-Xiang</given-names></name><xref ref-type="aff" rid="aff4"><sup>4</sup></xref><xref ref-type="corresp" rid="c001"><sup>&#x002A;</sup></xref>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &#x0026; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-review-editing/">Writing &#x2013; review &#x0026; editing</role>
</contrib>
</contrib-group>
<aff id="aff1"><label>1</label><institution>Beijing Engineering Research Center of Industrial Spectrum Imaging, School of Automation and Electrical Engineering, University of Science and Technology Beijing</institution>, <city>Beijing</city>, <country country="cn">China</country></aff>
<aff id="aff2"><label>2</label><institution>Department of Engineering Physics, Tsinghua University</institution>, <city>Beijing</city>, <country country="cn">China</country></aff>
<aff id="aff3"><label>3</label><institution>Center for Advanced Quantum Studies, School of Physics and Astronomy, Beijing Normal University</institution>, <city>Beijing</city>, <country country="cn">China</country></aff>
<aff id="aff4"><label>4</label><institution>Department of Nuclear Medicine, Beijing Tsinghua Changgung Hospital</institution>, <city>Beijing</city>, <country country="cn">China</country></aff>
<author-notes>
<corresp id="c001"><label>&#x002A;</label>Correspondence: Qingyang Wei, <email xlink:href="mailto:weiqy@ustb.edu.cn">weiqy@ustb.edu.cn</email>; Yaqiang Liu, <email xlink:href="mailto:liuyaqiang@tsinghua.edu.cn">liuyaqiang@tsinghua.edu.cn</email>; Zuo-Xiang He, <email xlink:href="mailto:zuoxianghe@hotmail.com">zuoxianghe@hotmail.com</email></corresp>
</author-notes>
<pub-date publication-format="electronic" date-type="pub" iso-8601-date="2025-12-03">
<day>03</day>
<month>12</month>
<year>2025</year>
</pub-date>
<pub-date publication-format="electronic" date-type="collection">
<year>2025</year>
</pub-date>
<volume>12</volume>
<elocation-id>1662020</elocation-id>
<history>
<date date-type="received">
<day>08</day>
<month>07</month>
<year>2025</year>
</date>
<date date-type="rev-recd">
<day>28</day>
<month>10</month>
<year>2025</year>
</date>
<date date-type="accepted">
<day>06</day>
<month>11</month>
<year>2025</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x00A9; 2025 Xu, Liu, Wei, Liu, Wu, Liu and He.</copyright-statement>
<copyright-year>2025</copyright-year>
<copyright-holder>Xu, Liu, Wei, Liu, Wu, Liu and He</copyright-holder>
<license>
<ali:license_ref start_date="2025-12-03">https://creativecommons.org/licenses/by/4.0/</ali:license_ref>
<license-p>This is an open-access article distributed under the terms of the <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">Creative Commons Attribution License (CC BY)</ext-link>. The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</license-p>
</license>
</permissions>
<abstract>
<p>Radionuclide imaging combines nuclear technique and medicine through the administration of radioactive drugs into living organisms, followed by imaging with specialized instruments. This technique is essential in modern medicine, facilitating diagnosis, treatment, medical research, exploration of drug mechanisms, and evaluation of drug efficacy. This review critically synthesizes the pivotal advancements in the field over the past decade, moving beyond a descriptive overview to analyze the clinical impact and translational barriers of emerging technologies. We evaluate key innovations in traditional modalities, such as the role of CZT detectors in transforming cardiac SPECT and the impact of TOF and DOI on quantitative accuracy in PET. Furthermore, we provide a comparative analysis of multimodal systems (e.g., PET/CT vs. PET/MRI), focusing on their clinical decision-making context. Emerging paradigms like self-collimation and cascade gamma photon imaging are examined as potential solutions to the inherent limitations of current systems, with a critical assessment of their technology readiness levels. A significant focus is placed on the rapidly evolving landscape of theranostics, highlighting the synergy between imaging and targeted radionuclide therapy. By identifying key trends, persistent challenges, and future directions, this review provides a comprehensive and critical perspective on the ongoing evolution of radionuclide imaging from a technological and clinical standpoint.</p>
</abstract>
<kwd-group>
<kwd>PET</kwd>
<kwd>SPECT</kwd>
<kwd>radionuclide</kwd>
<kwd>imaging technique</kwd>
<kwd>cascade gamma photon imaging</kwd>
</kwd-group>
<funding-group>
<funding-statement>The author(s) declare that financial support was received for the research and/or publication of this article. This research was funded by the National Key R&#x0026;D Program of China, grant number 2022YFC2402001, and the National Natural Science Foundation of China, grant number 12375337.</funding-statement>
</funding-group>
<counts>
<fig-count count="0"/>
<table-count count="1"/>
<equation-count count="0"/>
<ref-count count="158"/>
<page-count count="13"/>
<word-count count="13992"/>
</counts>
<custom-meta-group>
<custom-meta>
<meta-name>section-at-acceptance</meta-name>
<meta-value>Nuclear Medicine</meta-value>
</custom-meta>
</custom-meta-group>
</article-meta>
</front>
<body>
<sec sec-type="intro" id="sec1">
<label>1</label>
<title>Introduction</title>
<p>Radionuclide imaging, a critical intersection of nuclear technique and medicine, is an essential tool for visualizing specific molecular-level changes in living tissues, cells, and subcellular structures. Characterized by high sensitivity, specificity, and quantifiability, this technique enables observation of metabolic activities, blood perfusion, neural functions, cell receptors, and protein expression in specific organs or tissues. It aids in the diagnosis, staging, and monitoring of tumor progression, as well as in assessing neurological, cardiovascular, coronary artery disease (<xref ref-type="bibr" rid="ref1">1</xref>), and brain disorders (<xref ref-type="bibr" rid="ref2">2</xref>), providing essential evidence for early diagnosis and targeted treatment. It also monitors drug absorption, distribution, metabolism, and excretion to evaluate therapeutic effects, perform dosimetry analysis, and facilitate drug development.</p>
<p>Radionuclide imaging operates on the principle of administering radiopharmaceuticals into the living organism, which are circulating within the body and accumulate differently in normal and diseased tissues. As physiological activities such as organ metabolism occur, a three-dimensional dose distribution is formed within the body; the emitted gamma rays are detected, and an image of the 3D distribution of the radiopharmaceuticals is reconstructed (<xref ref-type="bibr" rid="ref3">3</xref>).</p>
<p>The most commonly used radionuclide imaging medical techniques include gamma camera, single photon emission computed tomography (SPECT), positron emission tomography (PET) and multimodality imaging techniques such as SPECT/CT, PET/CT and PET/MRI.</p>
<p>However, despite their widespread clinical success, conventional modalities like SPECT and PET face persistent limitations. SPECT&#x2019;s reliance on mechanical collimators severely compromises sensitivity for spatial resolution. PET, while more sensitive, still contends with challenges like the parallax effect and detector timing limits, which impact resolution and image quality. This fundamental trade-off between sensitivity and spatial resolution in both systems motivates the need for technological advancements.</p>
<p>This paper focuses on the recent advancements in radionuclide imaging, a rapidly growing field that has attracted substantial attention from research institutions globally. It aims to summarize the latest research achievements in this area over the past decade, covering a range of imaging techniques.</p>
</sec>
<sec id="sec2">
<label>2</label>
<title>Research progress of traditional radionuclide imaging techniques</title>
<p>The advent of the scanner in the 1950s marked the inception of radionuclide imaging (<xref ref-type="bibr" rid="ref4">4</xref>). A pivotal advancement occurred in 1964 with the introduction of the first scanner to utilize a single crystal scintillation detector (<xref ref-type="bibr" rid="ref5">5</xref>). This innovative device, endowed with the ability to delineate spatial distribution and temporal resolution, facilitated rapid imaging and the capture of dynamic physiological processes, known as the gamma camera or scintillation camera. Since the 1960s, gamma camera technology has progressed substantially, with recent developments focusing on portable intraoperative gamma cameras (IGCs). These devices provide real-time, high-resolution 2D imaging during surgery, offering significant advantages over conventional 1D gamma probes. Advances in detector materials, collimator geometries, and readout architectures have collectively enhanced the spatial resolution, sensitivity, and clinical versatility of IGCs, with hybrid imaging capabilities further supporting intraoperative decision-making (<xref ref-type="bibr" rid="ref6">6</xref>).</p>
<p>Technological advancements have markedly enhanced the performance of radionuclide imaging devices, leading to superior image quality and more precise disease identification, localization, and tracking. Key performance indicators for these devices include spatial resolution, sensitivity, noise equivalent count rate, timing resolution, and energy resolution. An ideal imaging system should feature low dead time, low scatter fraction, high counting capability, high energy resolution, and a high signal-to-noise ratio. Most importantly, it must maintain high sensitivity and spatial resolution, although these two factors often trade off against each other (<xref ref-type="bibr" rid="ref7">7</xref>). The overarching goal of radionuclide imaging development is to augment both device sensitivity and spatial resolution to attain higher-quality images and more accurate diagnostic information.</p>
<sec id="sec3">
<label>2.1</label>
<title>SPECT</title>
<p>Single-Photon Emission Computed Tomography (SPECT) is a type of ECT technology specifically designed for tomographic imaging of radiopharmaceuticals such as <sup>99m</sup>Tc (Technetium), <sup>131</sup>I (Iodine), <sup>111</sup>In (Indium), and <sup>201</sup>Tl (Thallium), which emit single gamma photons during each decay event (<xref ref-type="bibr" rid="ref8">8</xref>, <xref ref-type="bibr" rid="ref9">9</xref>). Its cost-effectiveness and independence from expensive cyclotron support have enabled SPECT to achieve widespread clinical application (<xref ref-type="bibr" rid="ref10">10</xref>). However, the development of SPECT technology has long been constrained by two fundamental physical limitations: sensitivity loss caused by mechanical collimation and the intrinsic spatial resolution limits imposed by detector materials (<xref ref-type="bibr" rid="ref11">11</xref>). These constraints result in significant partial volume effects, reducing image quantitative accuracy and potentially leading to the omission of small, early-stage lesions. To overcome these limitations, recent research on high-performance SPECT has primarily focused on two major directions: revolutionary advancements in detector technology and innovative system geometry design.</p>
<p>The detector serves as the core component of a SPECT system, and innovations in detector materials represent the fundamental driving force behind improved imaging performance. Traditionally, clinical SPECT detectors mainly utilize large-volume continuous thallium-doped sodium iodide (NaI(Tl)) crystals (typical size 500&#x202F;&#x00D7;&#x202F;400&#x202F;&#x00D7;&#x202F;9.5&#x202F;mm<sup>3</sup>) coupled with arrays of PMTs (<xref ref-type="bibr" rid="ref12">12</xref>). However, traditional large-volume NaI(Tl) crystals have poor intrinsic spatial resolution (3&#x202F;~&#x202F;5&#x202F;mm@140&#x202F;keV). Although efforts to improve spatial resolution have been made, such as the work by Rozler et al. (<xref ref-type="bibr" rid="ref13">13</xref>), who employed compact pixelated detectors with a pixel size of 2.75&#x202F;&#x00D7;&#x202F;2.75&#x202F;&#x00D7;&#x202F;10&#x202F;mm<sup>3</sup> in clinical SPECT systems, the hygroscopic nature of NaI(Tl) crystals complicates the fabrication process, thereby limiting further advancements in detector miniaturization.</p>
<p>To overcome the performance bottlenecks of traditional detectors, various novel scintillator materials have emerged. The advent of cadmium zinc telluride (CZT) semiconductor detectors marked a paradigm shift in SPECT technology (<xref ref-type="bibr" rid="ref14 ref15 ref16 ref17 ref18">14&#x2013;18</xref>), offering higher energy resolution, enhanced sensitivity, and a more compact structure (<xref ref-type="bibr" rid="ref19">19</xref>, <xref ref-type="bibr" rid="ref20">20</xref>). By directly digitizing photons, these detectors achieve improved sensitivity and spatial resolution, with pixel size in D-SPECT reaching 2.46&#x202F;&#x00D7;&#x202F;2.46&#x202F;&#x00D7;&#x202F;5&#x202F;mm<sup>3</sup> (<xref ref-type="bibr" rid="ref14">14</xref>). This technological breakthrough has directly led to the development of a new generation of high-performance SPECT systems, such as GE&#x2019;s Discovery NM/CT 870 CZT (<xref ref-type="bibr" rid="ref21">21</xref>) and Switzerland&#x2019;s Veriton-CT SPECT/CT (<xref ref-type="bibr" rid="ref22">22</xref>), both of which deliver faster acquisition speeds and superior energy discrimination (<xref ref-type="bibr" rid="ref23">23</xref>). Clinical evidence further demonstrates that CZT-SPECT supports low-dose, high-temporal-resolution gated nuclear cardiology imaging (<xref ref-type="bibr" rid="ref24">24</xref>, <xref ref-type="bibr" rid="ref25">25</xref>), enhancing the accuracy and reproducibility of quantitative cardiac functional parameters such as ejection fraction and filling rate (<xref ref-type="bibr" rid="ref26">26</xref>). Moreover, its excellent energy resolution provides a foundation for advanced applications like multi-isotope imaging. However, the high manufacturing cost of CZT crystals remains a major barrier to widespread adoption, making cost-effectiveness a critical factor in clinical decision-making.</p>
<p>Between NaI(Tl) and CZT, researchers have been actively exploring alternative materials that offer a more optimal balance between performance and cost. For instance, lanthanum bromide (LaBr&#x2083;) provides excellent light output and energy resolution (6%@140&#x202F;keV), yet its intrinsic background radiation and hygroscopic nature present practical challenges for clinical application. In recent years, cerium-doped gadolinium aluminum gallium garnet (GAGG) has become a popular scintillation crystal for SPECT due to its high light yield, fast decay time, high attenuation capability, lack of background radiation, and non-hygroscopic properties (<xref ref-type="bibr" rid="ref27 ref28 ref29 ref30">27&#x2013;30</xref>).</p>
<p>Regardless of the material used, the design of SPECT detectors has always faced a fundamental physical trade-off between sensitivity and spatial resolution. To ensure sufficient detection efficiency (sensitivity), the scintillation crystal must possess a certain thickness; however, increasing the thickness inevitably enhances light scattering or charge diffusion, thereby degrading spatial resolution. Although technologies such as micro-columnar CsI crystals can achieve exceptionally high resolution, their limited thickness results in poor detection efficiency (<xref ref-type="bibr" rid="ref31 ref32 ref33">31&#x2013;33</xref>). Consequently, optimizing the selection among different crystal materials&#x2014;such as GAGG, LaCl<sub>3</sub>, CsI, LaBr<sub>3</sub>, and YAlO<sub>3</sub>&#x2014;based on their physical characteristics for specific clinical applications represents a key challenge in the design of next-generation SPECT systems (<xref ref-type="bibr" rid="ref34">34</xref>).</p>
<p>In parallel with innovations in detector materials, optimizing system geometry to capture photon information more efficiently represents another critical avenue for enhancing SPECT performance. Multi-pinhole (MPH) collimation was originally introduced as an ingenious engineering strategy to compensate for the limited resolution of conventional detectors by leveraging the magnification effect of pinholes. This approach has achieved remarkable success in small-animal imaging, reaching submillimeter spatial resolution. For instance, an advanced multi-pinhole collimator small animal SPECT system (U-SPECT5/CT) developed at Delft University of Technology (<xref ref-type="bibr" rid="ref35">35</xref>, <xref ref-type="bibr" rid="ref36">36</xref>) achieved a spatial resolution of 0.25&#x202F;mm and a sensitivity of 0.038%, albeit with an effective field of view(FOV) of only about 1&#x202F;cm<sup>3</sup>. In recent years, this concept has been extended to clinical brain SPECT (<xref ref-type="bibr" rid="ref37">37</xref>) and whole-body SPECT (<xref ref-type="bibr" rid="ref38">38</xref>) imaging, where it has been combined with ring detector configurations to achieve spatial resolutions of 2&#x2013;3&#x202F;mm&#x2014;an improvement of 4&#x2013;5 times over traditional SPECT systems. However, this magnification-based strategy also introduces new constraints: the use of large, low-resolution detector modules limits system compactness and, consequently, the number of pinholes that can be integrated, thereby restricting further improvements in overall system sensitivity. However, this magnification-based strategy also introduces new constraints: the use of large-volume low-resolution detector modules limits system compactness and the number of pinhole collimators that can be integrated, thereby restricting further improvements in overall system sensitivity.</p>
<p>In contrast to the aforementioned strategy, another design approach combines ultra&#x2013;high-resolution detectors with a pinhole reduction imaging scheme (<xref ref-type="bibr" rid="ref31">31</xref>, <xref ref-type="bibr" rid="ref39">39</xref>, <xref ref-type="bibr" rid="ref40">40</xref>). This approach minimizes detector size, enabling a more compact system design that can accommodate a greater number of detectors within a limited space, thereby directly enhancing overall system sensitivity. For example, the MRC-SPECT-II system leverages the exceptionally high intrinsic resolution of CZT detectors (approximately 100&#x202F;&#x03BC;m) to support a complex collimator design incorporating 1,536 ultrafine pinholes (<xref ref-type="bibr" rid="ref39">39</xref>). Similarly, the FastSPECT-III system achieves high system sensitivity within a 15&#x202F;mm diameter imaging space by integrating 20 gamma cameras (<xref ref-type="bibr" rid="ref41">41</xref>). At the frontier of SPECT innovation, Laue lens diffraction imaging technology explores an entirely new physical principle, aiming to eliminate the need for conventional collimators and achieve a spatial resolution down to 0.113&#x202F;nL (<xref ref-type="bibr" rid="ref42">42</xref>).</p>
<p>The leap in SPECT performance is not an isolated technological advancement but rather the result of the synergistic evolution among hardware innovation, advanced algorithms, and clinical demands. Improvements in hardware resolution must be complemented by sophisticated image reconstruction algorithms capable of accurately correcting physical effects&#x2014;such as partial volume correction and dosimetry (<xref ref-type="bibr" rid="ref43">43</xref>)&#x2014;and leveraging deep learning&#x2013;based optimization techniques. Only through this integration can the full potential of modern SPECT systems be realized, enabling more precise diagnostic and therapeutic applications in cardiology, oncology, and neurology (<xref ref-type="bibr" rid="ref44">44</xref>).</p>
<p>In addition, specialized geometric designs can also enhance the spatial resolution and sensitivity of SPECT systems (<xref ref-type="bibr" rid="ref45">45</xref>, <xref ref-type="bibr" rid="ref46">46</xref>). These designs facilitate more efficient collection of gamma rays from the target. For instance, InSPira HD employs a ring-shaped detector system utilizing NaI(Tl) scintillators paired with adaptive collimators, achieving a spatial resolution of 6&#x2013;8&#x202F;mm full width at half maximum (FWHM).</p>
<p>This synergistic advancement in both hardware and software ultimately serves to deepen clinical applications. For instance, the superior energy resolution of modern detectors renders complex applications, such as dual-tracer imaging, more reliable. Examples include stress and rest myocardial perfusion imaging with <sup>99m</sup>Tc (140&#x202F;keV) and <sup>201</sup>Tl (75&#x202F;keV/167&#x202F;keV), as well as neurotransmitter agents labeled with <sup>123</sup>I (159&#x202F;keV). By acquiring data from different energy windows simultaneously, this approach not only shortens examination times but also ensures the perfect spatiotemporal registration of multiple physiological data sets, although crosstalk correction between the energy windows remains a primary focus of current research. In summary, breakthroughs in material science, ingenuity in system design, and enhanced computational power are collectively propelling SPECT towards higher precision, greater speed, and improved quantitative capabilities. This evolution is opening new frontiers for its theranostic applications in fields such as cardiology, oncology, and neurology.</p>
</sec>
<sec id="sec4">
<label>2.2</label>
<title>PET</title>
<p>Positron Emission Tomography (PET) is a form of ECT that utilizes positron-emitting radioactive isotopes, including <sup>11</sup>C, <sup>13</sup>N, <sup>15</sup>O, <sup>18</sup>F, <sup>64</sup>Cu, and <sup>82</sup>Rb (<xref ref-type="bibr" rid="ref47">47</xref>). PET employs coincidence detection technology, which eliminates the need for mechanical collimators. During imaging, positron-emitting nuclei decay within the biological source and release positrons. These positrons undergo annihilation, producing a pair of gamma photons, each with an energy of 511 keV and traveling in opposite directions. Within a designated time window (typically 0&#x2013;15&#x202F;ns), the system detects pairs of gamma photons at 180&#x00B0; (&#x00B1;0.25&#x00B0;) to each other, identifying them as coincidence events. The detected positions of the two gamma photons in a coincidence event are connected to generate a line of response (LOR), indicating the location of the radioactive isotope. This method is also known as electronic collimation. However, during the imaging process, PET is subject to various factors such as Compton scattering in the object, leading to discrepancies between the collected data and the actual conditions, resulting in image quality distortion (<xref ref-type="bibr" rid="ref48">48</xref>). Therefore, the development of PET technology is, in essence, a relentless pursuit of higher spatial and temporal resolution, aiming to approximate as closely as possible the true spatiotemporal coordinates of the annihilation events.</p>
<p>The foundation of precise detection lies in the choice of detector crystal material, which directly determines the ultimate performance limit of a PET system. The choice of detector crystal material significantly affects the performance of PET equipment. PET detector crystals require high density and atomic number to achieve high stopping power, rapid rise and decay times for improved timing resolution, and high light output for enhanced energy resolution, along with properties such as high mechanical strength and moisture resistance. From the early use of NaI to the mainstream adoption of bismuth germanate Bi<sub>4</sub>Ge<sub>3</sub>O<sub>12</sub> (BGO) and cerium-doped gadolinium oxyorthosilicate Gd<sub>2</sub>SiO<sub>5</sub>(Ce) (GSO), and further to the currently prevalent cerium-doped lutetium oxyorthosilicate Lu<sub>2</sub>SiO<sub>5</sub>(Ce) (LSO) and cerium-doped lutetium-yttrium oxyorthosilicate LYSO: Ce (LYSO) crystals, each iteration of detector materials has sought an optimal balance among these critical performance parameters. In recent years, fully digital PET detectors based on cadmium zinc telluride (CZT) have become a research hotspot (<xref ref-type="bibr" rid="ref49">49</xref>). Unlike conventional designs, they eliminate the need for scintillators and photoconversion, offering the potential for fundamental improvements in both energy and spatial resolution. However, every choice entails compromise&#x2014;no perfect crystal yet exists. Thus, the selection of detector materials remains a complex trade-off among equipment performance, manufacturing cost, and the specific requirements of clinical applications.</p>
<p>Beyond material selection, the physical segmentation of crystals represents the most direct approach to improving spatial resolution. By dividing the crystal into smaller elements, higher signal-to-noise ratio(SNR) can be achieved. For instance, the detector crystal unit size of the microPET scanner is approximately 1.5&#x202F;mm, yielding a resolution of 1.5&#x2013;1.75&#x202F;mm. Taking this concept further, finely segmented scintillation crystals can be stacked longitudinally and coupled with high-pixel photodetectors to track the interaction points of photons within the crystal. This enables three-dimensional spatial localization and establishes the foundation for higher-dimensional correction techniques.</p>
<p>If the optimization of crystal materials represents a &#x201C;quantitative&#x201D; enhancement in PET performance, then the introduction of Time-of-Flight (TOF) (<xref ref-type="bibr" rid="ref50">50</xref>) technology marks a true &#x201C;qualitative&#x201D; leap. The principle of TOF is based on the fact that the path length from the annihilation point to the detector varies for each coincident photon, resulting in different arrival times for individual gamma rays. TOF-PET utilizes the time difference of arrival of annihilation photons at the detector to confine the positron emission location to a small segment along the LOR connecting two scintillation crystals. In conventional PET image reconstruction, algorithms must distribute the probability of each detected event uniformly along the entire LOR, which inevitably amplifies the uncertainty of individual events and propagates it across the entire image&#x2014;becoming a major source of noise. TOF technology, by dramatically reducing this region of uncertainty, significantly enhances the SNR. This improvement in SNR yields substantial clinical benefits: images of equivalent quality can be obtained in a shorter acquisition time, higher-quality images can be achieved within the same scan duration, and in some cases, the administered radiopharmaceutical dose can even be reduced.</p>
<p>In the early stages, the limited timing resolution of conventional photomultiplier tubes (PMTs) and scintillation crystals&#x2014;typically greater than 1&#x202F;ns&#x2014;confined TOF technology to a theoretical concept for many years. It was not until the advent of fast-decay crystals such as LSO and LYSO, followed by breakthroughs in photodetector technology, that timing resolutions on the order of several hundred picoseconds became achievable (<xref ref-type="bibr" rid="ref51">51</xref>). As a result, TOF technology successfully transitioned from laboratory research to clinical application. The initial batch of commercial TOF-PET scanners, such as Philips&#x2019; 3D PET scanner (Ingenuity TF) (<xref ref-type="bibr" rid="ref52">52</xref>), featured timing resolutions between 500 and 600&#x202F;ps. To further enhance quantitative accuracy, recent reconstruction frameworks have incorporated simultaneous activity and attenuation estimation (SAA) into the TOF-PET model. Methods based on biconvex optimization with total variation constraints have improved stability and image quality over traditional approaches, enhancing TOF-PET quantification under clinical conditions (<xref ref-type="bibr" rid="ref53">53</xref>).</p>
<p>Pushing TOF timing to the tens of picosecond level has enabled a revolutionary paradigm: reconstruction-free PET. A recent study by Kwon et al. demonstrated this by achieving a 32&#x202F;ps timing resolution using prompt Cerenkov radiation, a novel integrated detector (CRI-MCP-PMT), and a CNN. This precision is sufficient to directly localize annihilation events (~4.8&#x202F;mm spatial precision), entirely bypassing tomographic reconstruction. This new modality, termed dPEI, promises to transform PET system design by eliminating the geometric and sampling constraints of traditional reconstruction (<xref ref-type="bibr" rid="ref54">54</xref>).</p>
<p>The utilization of Silicon Photomultipliers (SiPMs) has further enhanced the performance of TOF-PET (<xref ref-type="bibr" rid="ref55">55</xref>). SiPMs exhibit excellent internal timing resolution, thereby improving the sensitivity, image resolution, and maximum count rate of TOF-PET (<xref ref-type="bibr" rid="ref56">56</xref>, <xref ref-type="bibr" rid="ref57">57</xref>). The TOF timing resolution of SiPMs systems surpasses 200&#x202F;ps. To achieve a timing resolution of 100&#x202F;ps, a new detector design approach involves mounting SiPMs on the long edge of crystals instead of the traditional end-to-end installation (<xref ref-type="bibr" rid="ref58">58</xref>). Additionally, compared to the significantly larger PMTs used in traditional PET systems, SiPMs or Avalanche Photodiodes (APDs) (<xref ref-type="bibr" rid="ref59">59</xref>) enable direct one-to-one correspondence between the photodetector and the detector unit. This facilitates coupling with smaller crystal elements, leading to a spatial resolution improvement in PET. For example, United Imaging has improved the spatial resolution of PET to less than 2.35&#x202F;mm. Furthermore, SiPMs and APDs are immune to electromagnetic interference, making them suitable for PET/MRI multimodal imaging.</p>
<p>While advancements in SiPMs are pushing timing resolution towards the 100&#x202F;ps frontier, researchers are simultaneously exploring novel physical mechanisms to push far beyond this barrier. Two emerging technological routes are particularly prominent: Cherenkov radiation-based detection and liquid noble gas scintillation technology. The former approach utilizes the prompt Cherenkov photons generated by charged particles within crystals like BGO. Although this method faces challenges due to a low and stochastic photon yield, experimental detectors have achieved an ultra-fast timing resolution of approximately 30&#x202F;ps, which could enable novel scanner geometries such as dual-panel PET systems (<xref ref-type="bibr" rid="ref60">60</xref>, <xref ref-type="bibr" rid="ref61">61</xref>). The latter route is exemplified by the use of xenon-doped liquid argon (LAr + Xe), which offers a scintillation time about seven times faster and a 25% higher photon yield compared to LYSO (<xref ref-type="bibr" rid="ref62">62</xref>). By doping with xenon, this technology overcomes the inherent issues of pure LAr, such as a slow decay component and a mismatched emission wavelength, thereby significantly improving light detection efficiency and the system&#x2019;s ability to handle high event rates. A conceptual total-body scanner based on this technology, the 3D&#x03C0;, has demonstrated a simulated TOF resolution of 151&#x202F;ps and an exceptionally high system sensitivity of 373 kcps/MBq, validating the immense potential of this approach.</p>
<p>While TOF technology significantly enhances the SNR, another key advancement&#x2014;Depth of Interaction (DOI) information technology&#x2014;emerged to address a different limitation. When gamma photons enter a long crystal at an oblique angle, a phenomenon known as the parallax effect occurs, in which the estimated LOR deviates from its true position. This effect is particularly pronounced at the edges of FOV, leading to a degradation in spatial resolution. DOI can effectively enhance spatial resolution and reduce parallax effects, particularly for positions away from the center of the radial FOV. A variety of methods have been developed for DOI acquisition, including signal waveform signal waveform discrimination (<xref ref-type="bibr" rid="ref63">63</xref>, <xref ref-type="bibr" rid="ref64">64</xref>), spectral splitting (<xref ref-type="bibr" rid="ref65">65</xref>, <xref ref-type="bibr" rid="ref66">66</xref>), dual-ended readout (<xref ref-type="bibr" rid="ref67">67</xref>, <xref ref-type="bibr" rid="ref68">68</xref>), and innovative multilayer stacked scintillator arrays. For example, Binder et al. (<xref ref-type="bibr" rid="ref69">69</xref>) employed interleaved triple-layer stacked LYSO scintillator array detectors with DOI for high-resolution and high-sensitivity small animal PET scanners. Ullah et al. (<xref ref-type="bibr" rid="ref70">70</xref>) proposed a DOI detector utilizing scintillator emission wavelength, achieving excellent discrete DOI positioning accuracy with a DOI-separation FOM value of 1.5.</p>
<p>Currently, the state of the art small animal PET scanners&#x2014;such as Albira Si, HiPET, SIAT aPET and Beta-CUBE (<xref ref-type="bibr" rid="ref71">71</xref>)&#x2014;as well as dedicated brain PET scanners like the NeuroExplorer and SIAT bPET (<xref ref-type="bibr" rid="ref72">72</xref>), have universally integrated DOI measurement technology to ensure uniformly high spatial resolution across the entire FOV. For instance, the ultra&#x2013;high-resolution brain PET developed by Zeng et al. (<xref ref-type="bibr" rid="ref73">73</xref>) achieved an average spatial resolution of 1.53&#x202F;mm FWHM.</p>
<p>In addition to detector optimization, innovations in the overall geometric configuration of the scanner also play a crucial role in enhancing performance. The traditional ring-shaped design, while widely adopted, is not necessarily the optimal solution. For instance, helmet-type brain PET and cubic brain PET designs, which are wearable and cover the entire brain, exhibit exceptional sensitivity and spatial resolution (<xref ref-type="bibr" rid="ref74">74</xref>). The high-performance brain-dedicated PET scanner developed by Barrio et al. (<xref ref-type="bibr" rid="ref75">75</xref>) features both high resolution and sensitivity. This design consists of an elliptical cylinder that conforms to the shape of the human head, with additional front and back panels to increase coverage. It achieves a sensitivity of up to 23% in cortical regions and 16% at the center of FOV. Such optimized geometric configurations better accommodate local imaging needs, resulting in enhanced imaging quality and accuracy.</p>
<p>Moreover, integrating high-resolution virtual-pinhole PET devices into long-axial-FOV scanners can substantially enhance imaging performance, markedly improving both the detectability and contrast of small lesions (<xref ref-type="bibr" rid="ref76">76</xref>).</p>
</sec>
<sec id="sec5">
<label>2.3</label>
<title>Compton camera</title>
<p>The Compton camera is a technology that utilizes the Compton effect for gamma-ray detection and imaging. Its most prominent advantage is the absence of mechanical collimation and the large imaging FOV. The Compton effect refers to the scattering of incident photons with atomic electrons in a substance, where photons scatter in different directions, resulting in different wavelengths, also known as Compton scattering. The Compton camera features a four-fold imaging FOV, enabling visualization of radiation sources with electronic collimation (<xref ref-type="bibr" rid="ref77">77</xref>, <xref ref-type="bibr" rid="ref78">78</xref>). Based on the principle of Compton scattering, incoming gamma rays first undergo Compton scattering within the detector before experiencing the photoelectric effect. If the position and energy of each interaction are known, the Compton scattering angle can be calculated using the dynamic formula associated with the Compton effect. Lines connecting two interaction positions form the axis of a cone, with the angle derived from the scattering angle. Gamma-ray events must originate from the surface of this cone. As multiple such events are measured, the cones begin to converge at the true source position. In comparison to conventional modalities such as SPECT and SPECT/CT, which have demonstrated high diagnostic accuracy in specific clinical scenarios like unilateral condylar hyperplasia (UCH), the Compton camera represents a fundamentally different approach to gamma-ray imaging. While its design offers distinct advantages in terms of sensitivity and FOV, further research is required to validate its clinical applicability in UCH and other localized functional abnormalities (<xref ref-type="bibr" rid="ref79">79</xref>).</p>
<p>Early Compton camera detectors utilized scintillation crystals; however, later models increasingly adopted semiconductor materials, particularly CZT, due to their high energy resolution and higher atomic number, which enhances susceptibility to Compton scattering. Compared to silicon materials, CZT offers greater detection efficiency, and its suitability for operation at room temperature overcomes the limitation of germanium detectors, which require low-temperature conditions.</p>
<p>Gunma University in Japan (<xref ref-type="bibr" rid="ref80">80</xref>) has employed Si/CdTe Compton cameras for imaging radiopharmaceuticals such as <sup>99m</sup>Tc and <sup>18</sup>F. They successfully achieved <italic>in vivo</italic> tracer imaging in mice and conducted clinical trials. In 2019, Peng et al. (<xref ref-type="bibr" rid="ref81">81</xref>) proposed the compton-PET system, based on GAGG-SiPM pixelated detectors. They incorporated a thin detector layer into the PET system as a scattering layer to form a Compton imaging system, thereby enhancing the sensitivity of the entire imaging system. Another innovative approach in Compton camera design is the SiFi-CC proposed by the research group led by Jonas Kasper et al. (<xref ref-type="bibr" rid="ref82">82</xref>). It combines SiPMs with Compton cameras based on scintillating optical fibers. Both the scatterer and absorber are composed of elongated fibers made of high-density inorganic scintillating materials. This design exhibits a relatively low event pile-up rate in the detector, demonstrating high detection efficiency and rate capability due to its high granularity. Building on these advancements, recent prototypes such as the MACACO III Compton camera have further validated the feasibility of Compton-based imaging systems in clinical nuclear medicine. MACACO III successfully imaged both <sup>18</sup>F-FDG and <sup>131</sup>I tracers in phantom and patient studies, achieving spatial resolution superior to conventional gamma cameras and confirming its potential for radiopharmaceutical applications (<xref ref-type="bibr" rid="ref83">83</xref>). In parallel, Compton cameras employing GAGG scintillators have also shown promise in prompt gamma imaging during proton therapy, enabling real-time visualization of beam shape and range estimation. This non-invasive verification method highlights the expanding clinical role of gamma imaging technologies beyond conventional diagnostics (<xref ref-type="bibr" rid="ref84">84</xref>).</p>
</sec>
</sec>
<sec id="sec6">
<label>3</label>
<title>The development of multimodal imaging technology</title>
<p>Multimodal imaging technology has emerged as a significant focus in the field of radionuclide imaging, driven by the need for more comprehensive and accurate diagnostic tools. By integrating the complementary strengths of various imaging techniques, this technology enables the simultaneous acquisition of both functional metabolic and anatomical structural information in a single scan. This integration not only provides more comprehensive imaging data for disease diagnosis and treatment but also enhances the accuracy and reliability of imaging assessments, creating a synergistic effect where &#x201C;1&#x202F;+&#x202F;1&#x202F;&#x003E;&#x202F;2.&#x201D;</p>
<sec id="sec7">
<label>3.1</label>
<title>CT-based multimodal fusion systems</title>
<p>The development of multimodal imaging technology began with the need to solve the challenge of registering functional images (e.g., SPECT) with anatomical images (e.g., CT) (<xref ref-type="bibr" rid="ref85">85</xref>, <xref ref-type="bibr" rid="ref86">86</xref>). Before the advent of integrated hardware, researchers primarily relied on retrospective software-based image registration to fuse data from separate scanners, a process often complicated by inconsistencies in patient positioning, scan orientation, and image parameters between acquisitions. One of the pioneering efforts in SPECT/CT hardware fusion was accomplished by Hasegawa and his team at the University of California, San Francisco (UCSF). They configured a combined SPECT/CT prototype system by linking a clinical CT scanner (GE 9800) and a SPECT system (GE 600 XR/T) with a common patient table. This design allowed the patient to undergo both CT and SPECT scans in a single session via simple table translation, ensuring consistent patient geometry between the two datasets. The primary goal of this early work was not only to fuse functional and anatomical images but, more importantly, to use the high-resolution anatomical information from CT to perform accurate quantitative corrections for the SPECT data, such as patient-specific attenuation correction based on a CT-derived attenuation map and compensation for partial volume effects. This foundational research paved the way for subsequent commercial integrated SPECT/CT systems, the first of which became available for clinical use around 1999&#x2013;2000 (<xref ref-type="bibr" rid="ref87">87</xref>, <xref ref-type="bibr" rid="ref88">88</xref>).</p>
<p>SPECT/CT combines the functional imaging capabilities of SPECT with the anatomical imaging of CT, making it an advanced nuclear medicine imaging device (<xref ref-type="bibr" rid="ref89">89</xref>). This hybrid system addresses a critical limitation of conventional planar scintigraphy and standalone SPECT&#x2014;namely, the inability to precisely localize lesions within anatomical structures. In traditional SPECT applications such as benign and malignant bone diseases (<xref ref-type="bibr" rid="ref90">90</xref>), thyroid cancer (<xref ref-type="bibr" rid="ref91">91</xref>), neuroendocrine tumors, parathyroid adenomas, and sentinel lymph node (SLN) mapping of the head, neck, and pelvis regions (<xref ref-type="bibr" rid="ref92">92</xref>), the anatomical context offered by CT substantially enhances diagnostic accuracy and clinical confidence (<xref ref-type="bibr" rid="ref93">93</xref>). For example, in the diagnosis of pulmonary embolism (PE), ventilation/perfusion (V/Q) imaging combined with CT angiography demonstrates significantly higher diagnostic performance than standalone V/Q SPECT or Q SPECT imaging (<xref ref-type="bibr" rid="ref94">94</xref>, <xref ref-type="bibr" rid="ref95">95</xref>). Clinically, SPECT/CT remains a mainstream tool for diagnosing coronary artery disease due to its widespread use in myocardial perfusion imaging and its favorable cost-effectiveness.</p>
<p>Major medical equipment companies such as GE, Philips, and Siemens Healthcare have introduced their own SPECT/CT systems. These systems integrate dual-head SPECT and CT scanners, allowing imaging on the same platform, significantly improving scanning efficiency and image quality. For example, GE Healthcare&#x2019;s NM/CT 860 system has a scan time of less than 4&#x202F;min, while Philips&#x2019; Precedence&#x2122; system completes a whole-body scan in less than 60&#x202F;s. However, variations in system design also introduce specific clinical trade-offs. Another Philips SPECT/CT system, the BrightView XCT, combines a dual-head SPECT camera with a low-dose cone-beam CT. While it excels in anatomical high-resolution localization (0.33&#x202F;mm isotropic voxels) and high-quality attenuation correction, offering potential benefits such as reduced artifacts and shorter examination times, its key limitation lies in the relatively slow acquisition process. As a result, it is not suitable for dynamic contrast-enhanced diagnostic examinations or for use as a conventional CT scanner. Siemens Healthcare&#x2019;s Symbia&#x2122;TruePoint SPECT/CT combines variable-angle dual-detector SPECT with Emotion&#x2122;CT scanners in four different configurations, utilizing multi-detector CT components to obtain diagnostic-quality images. Despite the increasing technological maturity of SPECT/CT systems, their high cost continues to limit widespread adoption. Therefore, clinical decision-making must balance diagnostic benefits against cost-effectiveness. For instance, in the diagnostic pathway for UCH patients, SPECT alone is recommended as the primary imaging modality, as its diagnostic performance is sufficient while avoiding the potential drawbacks associated with SPECT/CT (<xref ref-type="bibr" rid="ref79">79</xref>).</p>
<p>Despite these limitations, recent advancements in SPECT/CT&#x2014;such as digital detectors, multidetector 3D geometries, and whole-body quantitative imaging&#x2014;are further enhancing its diagnostic and quantitative capabilities, aiming to narrow the performance gap with PET. These innovations not only enhance image quality but also expand its utility in theranostics, particularly in biodistribution assessment and dosimetry planning for radionuclide therapy. Despite ongoing limitations in resolution and sensitivity, the modality retains clinical value, especially for imaging long-lived isotopes and performing multi-tracer studies. In addition, 4D SPECT/CT has demonstrated improved localization accuracy in complex cases such as hyperparathyroidism, offering a cost-effective, lower-radiation alternative to more conventional imaging options (<xref ref-type="bibr" rid="ref96">96</xref>, <xref ref-type="bibr" rid="ref97">97</xref>).</p>
<p>Similar to SPECT, PET, lacking anatomical parameters to identify molecular events related to anatomy, is often integrated with Computed Tomography (CT) devices to form PET/CT systems. CT provides clear anatomical structure information, thereby enhancing the specificity and sensitivity of PET detection (<xref ref-type="bibr" rid="ref98 ref99 ref100 ref101">98&#x2013;101</xref>).</p>
<p>As a cornerstone of oncologic diagnosis, PET/CT has undergone continuous technological evolution aimed at improving scanning efficiency and quantitative accuracy. For example, the first continuous bed motion (CBM) PET/CT scanner introduced by Siemens AG, akin to spiral CT scanning, eliminates overlapping bed acquisitions. This system allows for flexible selection of the start and end positions for each body region within the PET scan coverage area, optimizing local sensitivity and improving axial noise uniformity. The sensitivity of PET/CT systems can be effectively increased with long axial FOV scanners that utilize silicon photomultipliers (SiPMs) detection systems. The 194&#x202F;cm FOV scanner developed by Badawi et al. (<xref ref-type="bibr" rid="ref102">102</xref>) significantly enhances sensitivity compared to standard axial FOV systems (<xref ref-type="bibr" rid="ref103">103</xref>). The clinical significance of this progress is substantial. For example, the world&#x2019;s first Biograph Vision Quadra PET/CT system from Siemens Healthineers features a FOV of 106&#x202F;cm, while the standard axial FOV measures 26.3&#x202F;cm. This scanner boasts a sensitivity of 174 cps/kBq and a time-of-flight (TOF) resolution of 219&#x202F;ps (<xref ref-type="bibr" rid="ref104">104</xref>), marking a 74% increase in sensitivity compared to PET devices using similar technology (<xref ref-type="bibr" rid="ref105">105</xref>). However, the inherent limitations of PET/CT are also well recognized: its relatively high ionizing radiation exposure restricts its use in pediatric populations or patients requiring frequent follow-up, and its soft-tissue contrast resolution is intrinsically inferior to that of magnetic resonance imaging (MRI).</p>
<p>In multimodal imaging systems, the quality of CT images plays a pivotal role in determining overall diagnostic performance. The presence of metallic implants within the scanning field of view often leads to severe CT artifacts (such as streaks and shadows) that degrade image quality, obscure accurate assessment of tissues adjacent to metal objects, and potentially compromise CT-based attenuation correction and radiotherapy treatment planning accuracy. To address these challenges, various metal artifact reduction (MAR) algorithms have been developed and implemented clinically. These methods mitigate artifacts by correcting either projection data or reconstructed image data, thereby enhancing diagnostic reliability and improving treatment planning precision in regions near metallic implants. However, conventional MAR techniques are not without limitations; they may introduce secondary artifacts or distort the apparent size and shape of the metallic implants, and their effectiveness can vary depending on the algorithm type and implant material.</p>
<p>In recent years, deep learning&#x2013;based reconstruction (DLR) has emerged as a promising artificial intelligence&#x2013;driven approach in CT image reconstruction (<xref ref-type="bibr" rid="ref106">106</xref>). DLR techniques have demonstrated great potential to produce images with lower noise and higher spatial resolution, while also showing advantages in artifact suppression and enabling reduced radiation dose scanning. Although the application and reliability of DLR in metal artifact correction remain under investigation, this approach represents a highly promising direction for improving CT image quality and, consequently, enhancing the overall performance of multimodal imaging systems.</p>
</sec>
<sec id="sec8">
<label>3.2</label>
<title>Exploration of emerging and advanced multimodal imaging technologies</title>
<p>Driven by the growing demand for non-ionizing radiation imaging and superior soft-tissue resolution, PET/MRI emerged, representing the advanced frontier of multimodal imaging. Compared to CT, magnetic resonance imaging (MRI) offers advantages such as non-ionizing radiation, excellent soft tissue resolution, multiple sequence acquisitions, and high spatial resolution. PET/MRI (<xref ref-type="bibr" rid="ref65">65</xref>, <xref ref-type="bibr" rid="ref107">107</xref>, <xref ref-type="bibr" rid="ref108">108</xref>) combines the ability of MRI to detect tissue density in soft tissues with the molecular detection capabilities of PET, enabling non-invasive, simple, and accurate acquisition of arterial input functions, thus achieving precise quantification of cerebral blood flow (CBF). Leveraging these strengths, PET/MRI is clinically positioned primarily for tumor and brain imaging, particularly in radiation-sensitive pediatric cases (<xref ref-type="bibr" rid="ref109">109</xref>). However, a significant drawback of PET/MRI, when compared to PET/CT, is its substantially higher cost. Additionally, the MR electromagnetic field may interfere with pacemakers, defibrillators, or other implantable devices that are susceptible to electromagnetic interference, limiting its use in certain patient populations.</p>
<p>Several research groups are actively working on developing various configurations of MRI-compatible PET systems. Systems from different manufacturers (or vendors) reflect various design trade-offs, for instance, Siemens&#x2019; mMR system, based on the Verio MR scanner (<xref ref-type="bibr" rid="ref110">110</xref>), incorporates PET detectors within the MR scanner, featuring a PET axial FOV of 25.8&#x202F;cm and a photon sensitivity of 2.47%, however, its disadvantage is the lack of TOF capabilities. In contrast, GE&#x2019;s Signa PET/MR (<xref ref-type="bibr" rid="ref111">111</xref>) utilizes silicon photomultipliers (SiPMs) for TOF, achieving a resolution of 400&#x202F;ps when the radiofrequency coil (RF) is open and 390&#x202F;ps when closed, with a PET axial FOV of 25&#x202F;cm and a photon sensitivity of 2.1%. In addition to Siemens and GE, United Imaging Healthcare is also a key participant in this field. Its uPMR 790 system utilizes a 32&#x202F;cm axial FOV with digital Time-of-Flight (TOF) PET technology, achieving an industry-leading 2.8&#x202F;mm NEMA spatial resolution (<xref ref-type="bibr" rid="ref112">112</xref>). The system&#x2019;s technology, derived from the uEXPLORER<sup>&#x00AE;</sup>, not only enhances routine clinical imaging capabilities, but its uSync research platform also provides new opportunities for advanced research, such as simultaneous cardiac PET/MR and functional neurological PET/MR.</p>
<p>Similarly, SPECT/MRI offers lower ionizing radiation doses and better imaging of soft tissues. The Hamamura group (<xref ref-type="bibr" rid="ref113">113</xref>) designed a miniaturized dual-modality SPECT/MRI system, integrating CZT nuclear radiation detectors into a 4&#x202F;T MRI system, enabling simultaneous acquisition of SPECT and MRI images. An important challenge facing SPECT/MRI is the system&#x2019;s magnetic compatibility. To address this issue, Hutton et al. (<xref ref-type="bibr" rid="ref114">114</xref>) developed the first MRI-compatible clinical SPECT system. The system consists of 20 MRI-compatible CsI(TI) detectors and a multi-slit collimator (<xref ref-type="bibr" rid="ref115">115</xref>). The scanner achieves a spatial resolution of 8&#x202F;mm (20&#x202F;cm D&#x202F;&#x00D7;&#x202F;9&#x202F;cm&#x202F;L) in the FOV and a sensitivity of 0.036%. Additionally, Xiaochun et al. (<xref ref-type="bibr" rid="ref116">116</xref>) studied a magnetic resonance-compatible SPECT system for simultaneous dual-mode imaging in small animals, achieving a spatial resolution of 350&#x202F;&#x03BC;m and an energy resolution of 3&#x2013;4&#x202F;keV. Although still in an exploratory stage, the development of these technologies provides strong support for the application of SPECT/MRI and opens up new possibilities for clinical medicine.</p>
<p>In addition to fusion with anatomical imaging, fusion between functional imaging modalities is also being explored. SPECT/PET molecular imaging represents an innovative multimodal imaging approach that enables simultaneous visualization of positron-emitting and single-photon-emitting nuclides (<xref ref-type="bibr" rid="ref117">117</xref>, <xref ref-type="bibr" rid="ref118">118</xref>). Several dual-head SPECT products currently available on the market also incorporate PET functionality, with some systems capable of simultaneously utilizing high-energy 511&#x202F;keV radioactive nuclides for SPECT/PET imaging (<xref ref-type="bibr" rid="ref119">119</xref>).</p>
<p>Combining Compton cameras with PET technology offers a promising solution for overcoming the limitations of PET in utilizing various radioactive tracers, particularly due to its suitability for multi-tracer imaging and high-energy radioactive tracer imaging. This integration allows for the simultaneous evaluation of different radioactive tracers under consistent conditions, thereby reducing errors associated with physical factors. Oganede et al. (<xref ref-type="bibr" rid="ref120">120</xref>) developed a Compton-PET hybrid camera capable of simultaneously imaging single gamma rays and annihilation radiation emitted by diagnostic and therapeutic nuclides. This system can image each nuclide in the presence of different isotopes and switch between Compton and PET modes by optimizing energy windows. Similarly, Kim et al. (<xref ref-type="bibr" rid="ref121">121</xref>) created a Compton imaging and PET coincidence system designed to monitor moving radioisotopes, leveraging Compton imaging to achieve a larger FOV. Yoshida et al. (<xref ref-type="bibr" rid="ref122">122</xref>) proposed a concept known as whole gamma imaging (WGI), which utilizes all detectable gamma rays for imaging, resulting in direct imaging with excellent outcomes. Additionally, Omata et al. (<xref ref-type="bibr" rid="ref123">123</xref>) developed a system capable of simultaneously performing three modes&#x2014;Compton, pinhole, and PET&#x2014;enabling the concurrent imaging of <sup>137</sup>Cs, <sup>22</sup>Na, and <sup>241</sup>Am within the same FOV.</p>
<p>The emergence of tri-modal and quad-modal imaging systems has significantly expanded the scope and possibilities of imaging technology. Siemens&#x2019; Inveon system, a tri-modal imaging platform, integrates PET, SPECT, and CT modalities. It can be equipped with various parallel-hole, single-pinhole, or multi-pinhole collimators for whole-body and brain imaging in mice, achieving sub-millimeter spatial resolution. Similarly, Gamma Medica&#x2019;s Triumph Trimodality scanner combines LabPET (PET), X-SPECT (SPECT), and X-O (CT) modes, specifically designed for preclinical and biomedical research applications in small animals. Wei et al. (<xref ref-type="bibr" rid="ref124">124</xref>) developed a high-performance integrated animal PET/SPECT/CT system capable of performing tri-modal imaging of animals. Additionally, fluorescence molecular tomography (FMT), as a novel optical molecular imaging technique, has also been applied in multi-modal systems. The imaging principle of FMT involves injecting fluorescent substances into the subject, externally exciting fluorescence with light, collecting fluorescence photon information with detectors, and reconstructing images. Zhou et al. (<xref ref-type="bibr" rid="ref125">125</xref>) developed a novel quad-modal small animal molecular imaging device, integrating CT, PET, SPECT, and FMT in the same system, enabling simultaneous multimodal imaging of the subject. The emergence of these multi-modal systems will provide more comprehensive and diversified imaging capabilities for scientific research and clinical applications, potentially leading to greater breakthroughs in disease diagnosis and treatment.</p>
</sec>
</sec>
<sec id="sec9">
<label>4</label>
<title>Innovative radionuclide imaging technology</title>
<sec id="sec10">
<label>4.1</label>
<title>Self-collimation</title>
<p>Self-collimation technology is an innovative approach to enhancing SPECT imaging performance. Traditional collimators are crucial components of SPECT, used for spatial localization selection (<xref ref-type="bibr" rid="ref126">126</xref>, <xref ref-type="bibr" rid="ref127">127</xref>). However, mechanical collimators&#x2014;typically made from heavy metals like lead or tungsten&#x2014;absorb over 99.90% of photons during imaging, limiting both resolution and detection efficiency. Although methods such as multi-pinhole collimation and increased coverage solid angle have been implemented to improve traditional SPECT systems, their sensitivity remains significantly constrained by the reliance on physical collimators. The introduction of self-collimation technology effectively addresses this limitation, leading to improved imaging performance in SPECT systems (<xref ref-type="bibr" rid="ref128">128</xref>).</p>
<p>Ma et al. developed a self-collimating SPECT system (<xref ref-type="bibr" rid="ref128 ref129 ref130 ref131">128&#x2013;131</xref>), in which the detectors themselves act as collimators. Arranged in a sparse array configuration within three-dimensional space, the detectors allow gamma photons to naturally collimate through absorption on their units. This design eliminates the need for traditional mechanical collimators. By achieving high spatial resolution without the significant photon loss associated with mechanical collimators, it overcomes the limitations of conventional systems and ensures high detection efficiency (<xref ref-type="bibr" rid="ref128">128</xref>). For instance, a simulated human brain SPECT system utilizing this technology achieved an average sensitivity of 3.88%, which is more than an order of magnitude higher than conventional clinical SPECT systems that typically have sensitivities below 0.1%. This approach fundamentally resolves the trade-off between spatial resolution and detection efficiency caused by mechanical absorption collimation, resulting in a significant breakthrough in SPECT performance.</p>
<p>Building on this principle, Tsinghua University has developed a high-performance cardiac SPECT system (<xref ref-type="bibr" rid="ref132">132</xref>) and a self-collimating SPECT system for small animals. The small animal self-collimating SPECT employs LYSO/GAGG composite detectors (<xref ref-type="bibr" rid="ref133">133</xref>), with detector units measuring 1.35&#x202F;&#x00D7;&#x202F;2.7&#x202F;&#x00D7;&#x202F;7&#x202F;mm<sup>3</sup>, providing high sensitivity to 140&#x202F;keV gamma photons and achieving an inherent spatial resolution of 1.35&#x202F;mm in one direction. The enhanced sensitivity and spatial resolution in the outermost layer of detectors significantly improve the overall imaging performance of the system. Guo et al. (<xref ref-type="bibr" rid="ref134">134</xref>) conducted simulations on a whole-body self-collimating SPECT system and proposed a design for single-photon emission breast tomography (SC-SPEBT) based on self-collimation (<xref ref-type="bibr" rid="ref135">135</xref>). SC-SPEBT consists of six detector panels that form a cylindrical FOV of 180&#x202F;mm&#x202F;&#x00D7;&#x202F;160&#x202F;mm. The imaging system offers a resolution of 3&#x202F;mm and a detection efficiency of 4.8%. Compared to planar molecular breast imaging, lesion detectability is improved. These studies underscore the significant potential of self-collimation technology in enhancing the performance of SPECT systems.</p>
</sec>
<sec id="sec11">
<label>4.2</label>
<title>Cascade gamma photon imaging technique</title>
<p>Cascade radiation refers to the phenomenon in which a nucleus undergoes transitions from higher to lower energy levels during a single decay event, emitting two or more gamma photons of specific energies in quick succession. The cascade radiation photon pairs provide significantly better localization information about the nucleus compared to single-photon events in SPECT. Currently, the most commonly used radionuclides for cascade gamma imaging research are <sup>111</sup>In (<xref ref-type="bibr" rid="ref136">136</xref>, <xref ref-type="bibr" rid="ref137">137</xref>) and <sup>177</sup>Lu (<xref ref-type="bibr" rid="ref138 ref139 ref140">138&#x2013;140</xref>). However, conventional PET imaging in nuclear medicine cannot image cascade radionuclides. SPECT relies solely on physical collimators and is unable to directly locate the position of nuclear decay or utilize the characteristics of cascade decay, thus limiting its ability to fully exploit the imaging potential of cascade radionuclides (<xref ref-type="bibr" rid="ref141">141</xref>, <xref ref-type="bibr" rid="ref142">142</xref>). As a result, current clinical equipment in nuclear medicine has certain limitations regarding cascade radiation and cannot be used effectively (<xref ref-type="bibr" rid="ref143">143</xref>). In recent years, advancements in detector and collimator technologies have led to a surge in research on cascade gamma photon coincidence imaging.</p>
<p>The detection methods and related performance of some existing cascade gamma photon coincidence imaging systems are shown in <xref ref-type="table" rid="tab1">Table 1</xref>. In 2018, Pahlka et al. (<xref ref-type="bibr" rid="ref144">144</xref>) from the M.D. Anderson Cancer Center in Texas, USA, designed the system for cascade gamma photon coincidence imaging with the spatial resolution better than 7.2&#x202F;mm, but the detection sensitivity was only 6&#x202F;&#x00D7;&#x202F;10<sup>&#x2212;8</sup>. The Mizuki research group (<xref ref-type="bibr" rid="ref145 ref146 ref147">145&#x2013;147</xref>) from the University of Tokyo verified the feasibility of cascade gamma photon coincidence imaging using the Compton imaging principle. The system achieved a high coincidence detection sensitivity of 3.57&#x202F;&#x00D7;&#x202F;10<sup>&#x2212;6</sup>, but the spatial resolution is only 28&#x202F;mm. In 2020, Chiang et al. (<xref ref-type="bibr" rid="ref148">148</xref>) from Chang Gung University in Taiwan combined TOF technology with positron emission tomography (PET) to achieve collimation without a traditional collimator. The detection sensitivity for coincidences was approximately 2&#x202F;&#x00D7;&#x202F;10<sup>&#x2212;3</sup>, but the spatial resolution was only 20&#x202F;mm. Liu et al. (<xref ref-type="bibr" rid="ref149">149</xref>, <xref ref-type="bibr" rid="ref150">150</xref>) from the Department of Physics at Tsinghua University proposed a real-time imaging cascade gamma photon coincidence imaging system, achieving a coincidence detection sensitivity of 3.4&#x202F;&#x00D7;&#x202F;10<sup>&#x2212;6</sup> and a spatial resolution of approximately 7.0&#x202F;mm.</p>
<table-wrap position="float" id="tab1">
<label>Table 1</label>
<caption>
<p>Performance comparison of various detection methods for cascade gamma photon coincidence imaging systems.</p>
</caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th align="left" valign="top">Detection scheme</th>
<th align="center" valign="top">TOF-PET</th>
<th align="center" valign="top">GAGG-SiPM Compton imaging</th>
<th align="center" valign="top">Parallel-hole collimator with dual NaI detectors</th>
<th align="center" valign="top">Parallel-hole collimator with GAGG-SiPM</th>
</tr>
</thead>
<tbody>
<tr>
<td align="left" valign="middle">Current research status</td>
<td align="center" valign="middle">Monte Carlo simulation</td>
<td align="center" valign="middle">Experimental modules</td>
<td align="center" valign="middle">Monte Carlo simulation</td>
<td align="center" valign="middle">Experimental modules</td>
</tr>
<tr>
<td align="left" valign="middle">Coincidence efficiency</td>
<td align="center" valign="middle">2&#x202F;&#x00D7;&#x202F;10<sup>&#x2212;3</sup></td>
<td align="center" valign="middle">3.57&#x202F;&#x00D7;&#x202F;10<sup>&#x2212;6</sup></td>
<td align="center" valign="middle">6&#x202F;&#x00D7;&#x202F;10<sup>&#x2212;8</sup></td>
<td align="center" valign="middle">~10<sup>&#x2212;8</sup></td>
</tr>
<tr>
<td align="left" valign="middle">Spatial resolution</td>
<td align="center" valign="middle">20&#x202F;mm</td>
<td align="center" valign="middle">28&#x202F;mm</td>
<td align="center" valign="middle">7.2&#x202F;mm</td>
<td align="center" valign="middle">4.1&#x202F;mm</td>
</tr>
<tr>
<td align="left" valign="middle">Energy resolution</td>
<td align="center" valign="middle">12&#x2013;18%@511&#x202F;keV</td>
<td align="center" valign="middle">12.4%@662&#x202F;keV</td>
<td align="center" valign="middle">Null</td>
<td align="center" valign="middle">10.2%@245&#x202F;keV</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>To understand the practical significance of these performance values (such as a spatial resolution of ~7.0&#x202F;mm), the key is to compare them with the performance of standard SPECT systems. According to recent reviews, the collimator is the primary determinant of extrinsic spatial resolution in clinical SPECT, with typical values ranging from 6 to 15&#x202F;mm at a 10&#x202F;cm source-collimator distance (<xref ref-type="bibr" rid="ref44">44</xref>). From this perspective, the best spatial resolution achieved by an experimental cascade imaging system (~7.0&#x202F;mm) falls within the higher end of the typical clinical SPECT performance range. However, a more significant challenge lies in detection sensitivity. The reported coincidence sensitivities for these prototype systems, ranging from 10<sup>&#x2212;8</sup> to 10<sup>&#x2212;6</sup>, are several orders of magnitude lower than those of conventional clinical systems. This low sensitivity is a primary barrier to acquiring images with adequate statistics in a clinically feasible scan time and represents the main hurdle for clinical translation.</p>
<p>Based on the analysis above, it is evident that while there have been advancements in cascade gamma photon coincidence imaging technology in recent years, a significant gap remains before these systems can be applied clinically. There is a strong demand in the field of radionuclide imaging for the development of high-performance, novel systems specifically designed for cascade gamma photon radiation detection and imaging.</p>
</sec>
</sec>
<sec id="sec12">
<label>5</label>
<title>Summary and prospect</title>
<p>This paper systematically reviews the technological advancements in the field of radionuclide imaging over the past decade, covering performance breakthroughs in traditional imaging (PET and SPECT), the evolution of multimodal fusion systems, and the exploration of cutting-edge technologies such as self-collimation and cascade gamma photon imaging. A review of these developments reveals that the core driving force of the entire field lies in continuously challenging the physical limits of imaging to meet the growing clinical demand for precision diagnosis and therapy. However, the path from technological innovation to clinical application remains challenging.</p>
<p>Looking ahead, the development of radionuclide imaging technology will be characterized by several key trends.</p>
<p>The first major trend is the deepening and maturation of theranostics, which currently represents the most promising development direction in nuclear medicine. The core of this strategy lies in using radiopharmaceuticals that possess both diagnostic imaging and targeted therapeutic functions to achieve precise disease assessment and personalized treatment. For example, radionuclides like <sup>177</sup>Lu and <sup>90</sup>Y emit both therapeutic <italic>&#x03B2;</italic>-rays and medium-energy <italic>&#x03B3;</italic>-photons suitable for SPECT imaging during their decay. This dual capability holds significant promise for simultaneous therapy and imaging, presenting vast prospects for theranostic applications (<xref ref-type="bibr" rid="ref151">151</xref>). The tremendous success of <sup>177</sup>Lu-based drugs in treating neuroendocrine tumors and prostate cancer in recent years has fully demonstrated the clinical value of this paradigm (<xref ref-type="bibr" rid="ref152">152</xref>, <xref ref-type="bibr" rid="ref153">153</xref>). To fully unleash the potential of theranostics, challenges must still be overcome. Future research will focus on a deeper understanding of the physical properties of complex radionuclides, such as non-pure positron emitters, to develop more agents with excellent theranostic characteristics (<xref ref-type="bibr" rid="ref154">154</xref>). Meanwhile, accurate in-vivo dosimetry is key to personalized therapy. This not only requires imaging systems capable of precise quantification of therapeutic radionuclides but also leverages advanced algorithms like artificial intelligence&#x2014;for instance, using deep learning to generate attenuation maps for improved SPECT quantification (<xref ref-type="bibr" rid="ref155">155</xref>)&#x2014;to establish a more precise, closed-loop theranostic workflow.</p>
<p>The second major driver is the leap from qualitative assessment to absolute quantification. With improvements in system performance and the refinement of correction algorithms, the future of radionuclide imaging will fully embrace an era of &#x201C;quantification.&#x201D; This implies moving beyond semi-quantitative metrics like the standardized uptake value to achieve absolute quantification of radiopharmaceutical concentration within lesions. This will enable the precise assessment of tumor heterogeneity, monitoring of early therapeutic response in small lesions, and provision of critical data for drug development.</p>
<p>Furthermore, artificial intelligence (AI), particularly deep learning, is set to permeate every aspect of radionuclide imaging. Beyond the well-researched application of CT-free attenuation correction in SPECT (<xref ref-type="bibr" rid="ref156">156</xref>), AI will also play a critical role in multiple other domains, including image reconstruction and denoising (<xref ref-type="bibr" rid="ref157">157</xref>), image analysis and diagnostic support (<xref ref-type="bibr" rid="ref158">158</xref>), and workflow optimization. Examples include developing intelligent reconstruction algorithms capable of processing low-dose, fast-scan data, thereby further reducing patient radiation dose and examination time while maintaining image quality. AI will also be used to automatically identify, segment, and quantify lesions, providing more stable and reproducible quantitative results, and to construct predictive models based on multimodal imaging data to aid in clinical decision-making. Additionally, it will automate scanning protocols and image post-processing workflows, enhancing equipment operational efficiency.</p>
<p>Finally, the continuous exploration of novel detectors and system designs persists. The endless pursuit of higher-performance detector materials will continue to drive breakthroughs in the temporal, energy, and spatial resolution of imaging systems. Simultaneously, dedicated high-resolution imaging systems for specific clinical needs (such as brain or breast imaging), as well as ultra-high-sensitivity systems capable of total-body coverage, will open new avenues for systems biology research and ultra-early disease screening.</p>
<p>In summary, radionuclide imaging is transitioning from a field primarily focused on morphological and functional observation to a modern medical imaging discipline centered on precise quantification, multidimensional information fusion, and integrated diagnostics and therapy. Future breakthroughs will depend not only on innovations in physics and engineering but also on deep interdisciplinary integration with clinical medicine, pharmacology, and data science to ultimately achieve a deeper understanding of diseases and more effective interventions.</p>
</sec>
</body>
<back>
<sec sec-type="author-contributions" id="sec13">
<title>Author contributions</title>
<p>SX: Conceptualization, Formal analysis, Investigation, Writing &#x2013; original draft, Data curation. GL: Formal analysis, Investigation, Visualization, Writing &#x2013; review &#x0026; editing. QW: Project administration, Supervision, Writing &#x2013; review &#x0026; editing. HL: Writing &#x2013; review &#x0026; editing. JW: Writing &#x2013; review &#x0026; editing. YL: Supervision, Writing &#x2013; review &#x0026; editing. Z-XH: Supervision, Writing &#x2013; review &#x0026; editing.</p>
</sec>
<sec sec-type="COI-statement" id="sec14">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
<p>The reviewer JJ declared a shared affiliation with the author(s) JW to the handling editor at the time of review.</p>
</sec>
<sec sec-type="ai-statement" id="sec15">
<title>Generative AI statement</title>
<p>The authors declare that no Gen AI was used in the creation of this manuscript.</p>
<p>Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.</p>
</sec>
<sec sec-type="disclaimer" id="sec16">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ref-list>
<title>References</title>
<ref id="ref1"><label>1.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Tout</surname> <given-names>D</given-names></name> <name><surname>Tonge</surname> <given-names>CM</given-names></name> <name><surname>Muthu</surname> <given-names>S</given-names></name> <name><surname>Arumugam</surname> <given-names>P</given-names></name></person-group>. <article-title>Assessment of a protocol for routine simultaneous myocardial blood flow measurement and standard myocardial perfusion imaging with rubidium-82 on a high count rate positron emission tomography system</article-title>. <source>Nucl Med Commun</source>. (<year>2012</year>) <volume>33</volume>:<fpage>1202</fpage>&#x2013;<lpage>11</lpage>. doi: <pub-id pub-id-type="doi">10.1097/MNM.0b013e3283567554</pub-id>, PMID: <pub-id pub-id-type="pmid">22760302</pub-id></mixed-citation></ref>
<ref id="ref2"><label>2.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Kochebina</surname> <given-names>O</given-names></name> <name><surname>Jan</surname> <given-names>S</given-names></name> <name><surname>Stute</surname> <given-names>S</given-names></name> <name><surname>Sharyy</surname> <given-names>V</given-names></name> <name><surname>Verrecchia</surname> <given-names>P</given-names></name> <name><surname>Mancardi</surname> <given-names>X</given-names></name> <etal/></person-group>. <article-title>Performance estimation for the high resolution CaLIPSO brain PET scanner: a simulation study</article-title>. <source>IEEE Trans Radiat Plasma Med Sci</source>. (<year>2018</year>) <volume>3</volume>:<fpage>363</fpage>&#x2013;<lpage>70</lpage>. doi: <pub-id pub-id-type="doi">10.1109/trpms.2018.2880811</pub-id>, PMID: <pub-id pub-id-type="pmid">41116384</pub-id></mixed-citation></ref>
<ref id="ref3"><label>3.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ritt</surname> <given-names>P</given-names></name> <name><surname>Vija</surname> <given-names>H</given-names></name> <name><surname>Hornegger</surname> <given-names>J</given-names></name> <name><surname>Kuwert</surname> <given-names>T</given-names></name></person-group>. <article-title>Absolute quantification in spect</article-title>. <source>Eur J Nucl Med Mol Imaging</source>. (<year>2011</year>) <volume>38</volume>:<fpage>69</fpage>&#x2013;<lpage>77</lpage>. doi: <pub-id pub-id-type="doi">10.1007/s00259-011-1770-8</pub-id>, PMID: <pub-id pub-id-type="pmid">21484383</pub-id></mixed-citation></ref>
<ref id="ref4"><label>4.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Cassen</surname> <given-names>B</given-names></name> <name><surname>Curtis</surname> <given-names>L</given-names></name> <name><surname>Reed</surname> <given-names>C</given-names></name> <name><surname>Libby</surname> <given-names>R</given-names></name></person-group>. <article-title>Instrumentation for I$sup 131$ use in medical studies</article-title>. <source>Nucleonics</source>. (<year>1951</year>) <volume>9</volume>:<fpage>46</fpage>&#x2013;<lpage>50</lpage>. osti id:4402877</mixed-citation></ref>
<ref id="ref5"><label>5.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Zimmerman</surname> <given-names>RE</given-names></name></person-group>. <article-title>Gamma cameras--state of the art</article-title>. <source>Med Instrum</source>. (<year>1979</year>) <volume>13</volume>:<fpage>161</fpage>&#x2013;<lpage>4</lpage>. PMID: <pub-id pub-id-type="pmid">440176</pub-id></mixed-citation></ref>
<ref id="ref6"><label>6.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Farnworth</surname> <given-names>AL</given-names></name> <name><surname>Bugby</surname> <given-names>SL</given-names></name></person-group>. <article-title>Intraoperative gamma cameras: a review of development in the last decade and future outlook</article-title>. <source>J Imaging</source>. (<year>2023</year>) <volume>9</volume>:<fpage>102</fpage>. doi: <pub-id pub-id-type="doi">10.3390/jimaging9050102</pub-id>, PMID: <pub-id pub-id-type="pmid">37233321</pub-id></mixed-citation></ref>
<ref id="ref7"><label>7.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Gong</surname> <given-names>K</given-names></name> <name><surname>Majewski</surname> <given-names>S</given-names></name> <name><surname>Kinahan</surname> <given-names>PE</given-names></name> <name><surname>Harrison</surname> <given-names>RL</given-names></name> <name><surname>Elston</surname> <given-names>BF</given-names></name> <name><surname>Manjeshwar</surname> <given-names>R</given-names></name> <etal/></person-group>. <article-title>Designing a compact high performance brain PET scanner&#x2014;simulation study</article-title>. <source>Phys Med Biol</source>. (<year>2016</year>) <volume>61</volume>:<fpage>3681</fpage>&#x2013;<lpage>97</lpage>. doi: <pub-id pub-id-type="doi">10.1088/0031-9155/61/10/3681</pub-id>, PMID: <pub-id pub-id-type="pmid">27081753</pub-id></mixed-citation></ref>
<ref id="ref8"><label>8.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Chen</surname> <given-names>L</given-names></name> <name><surname>Tsui</surname> <given-names>BMW</given-names></name> <name><surname>Mok</surname> <given-names>GSP</given-names></name></person-group>. <article-title>Design and evaluation of two multi-pinhole collimators for brain SPECT</article-title>. <source>Ann Nucl Med</source>. (<year>2017</year>) <volume>31</volume>:<fpage>636</fpage>&#x2013;<lpage>48</lpage>. doi: <pub-id pub-id-type="doi">10.1007/s12149-017-1195-y</pub-id>, PMID: <pub-id pub-id-type="pmid">28755084</pub-id></mixed-citation></ref>
<ref id="ref9"><label>9.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Deng</surname> <given-names>X</given-names></name> <name><surname>Chen</surname> <given-names>S</given-names></name> <name><surname>Li</surname> <given-names>X</given-names></name> <name><surname>Xu</surname> <given-names>C</given-names></name> <name><surname>Yang</surname> <given-names>X</given-names></name> <name><surname>Zheng</surname> <given-names>S</given-names></name> <etal/></person-group>. <article-title>Development of an adaptive clinical SPECT/CT system with full-ring detectors and multi-pinhole</article-title>. <source>J Nucl Med</source>. (<year>2021</year>) <volume>62</volume>:<fpage>317</fpage>&#x2013;<lpage>323</lpage>.</mixed-citation></ref>
<ref id="ref10"><label>10.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Xu</surname> <given-names>SY</given-names></name> <name><surname>Cao</surname> <given-names>DQ</given-names></name> <name><surname>Liang</surname> <given-names>WZ</given-names></name> <name><surname>Wei</surname> <given-names>QY</given-names></name></person-group>. <article-title>Research progress of single-photon emission computed tomography equipment</article-title>. <source>Chin Med Equip</source>. (<year>2022</year>) <volume>19</volume>:<fpage>156</fpage>&#x2013;<lpage>61</lpage>. doi: <pub-id pub-id-type="doi">10.3969/J.ISSN.1672-8270.2022.10.034</pub-id></mixed-citation></ref>
<ref id="ref11"><label>11.</label><mixed-citation publication-type="book"><person-group person-group-type="author"><name><surname>Katal</surname> <given-names>S</given-names></name> <name><surname>Gholamrezanezhad</surname> <given-names>A</given-names></name></person-group>. <article-title>Miscellaneous: SPECT and SPECT/CT for brain and inflammation imaging and radiation planning</article-title> In: <source>Clinical applications of SPECT-CT</source>. <publisher-loc>Cham</publisher-loc>: <publisher-name>Springer International Publishing</publisher-name> (<year>2021</year>). <fpage>305</fpage>&#x2013;<lpage>20</lpage>.</mixed-citation></ref>
<ref id="ref12"><label>12.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Madsen</surname> <given-names>MT</given-names></name></person-group>. <article-title>Recent advances in SPECT imaging</article-title>. <source>J Nucl Med</source>. (<year>2007</year>) <volume>48</volume>:<fpage>661</fpage>&#x2013;<lpage>73</lpage>. doi: <pub-id pub-id-type="doi">10.2967/jnumed.106.032680</pub-id>, PMID: <pub-id pub-id-type="pmid">17401106</pub-id></mixed-citation></ref>
<ref id="ref13"><label>13.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Rozler</surname> <given-names>M</given-names></name> <name><surname>Liang</surname> <given-names>H</given-names></name> <name><surname>Sabet</surname> <given-names>H</given-names></name> <name><surname>Chang</surname> <given-names>W</given-names></name></person-group>. <article-title>Development of a cost-effective modular pixelated NaI (Tl) detector for clinical SPECT applications</article-title>. <source>IEEE Trans Nucl Sci</source>. (<year>2012</year>) <volume>59</volume>:<fpage>1831</fpage>&#x2013;<lpage>40</lpage>. doi: <pub-id pub-id-type="doi">10.1109/TNS.2012.2210908</pub-id>, PMID: <pub-id pub-id-type="pmid">24146436</pub-id></mixed-citation></ref>
<ref id="ref14"><label>14.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Erlandsson</surname> <given-names>K</given-names></name> <name><surname>Kacperski</surname> <given-names>K</given-names></name> <name><surname>Van Gramberg</surname> <given-names>D</given-names></name> <name><surname>Hutton</surname> <given-names>BF</given-names></name> <etal/></person-group>. <article-title>Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology</article-title>. <source>Phys Med Biol</source>. (<year>2009</year>) <volume>54</volume>:<fpage>2635</fpage>&#x2013;<lpage>49</lpage>. doi: <pub-id pub-id-type="doi">10.1088/0031-9155/54/9/003</pub-id>, PMID: <pub-id pub-id-type="pmid">19351981</pub-id></mixed-citation></ref>
<ref id="ref15"><label>15.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Bordonne</surname> <given-names>M</given-names></name> <name><surname>Chawki</surname> <given-names>MB</given-names></name> <name><surname>Marie</surname> <given-names>PY</given-names></name> <name><surname>Zaragori</surname> <given-names>T</given-names></name> <name><surname>Roch</surname> <given-names>V</given-names></name> <name><surname>Grignon</surname> <given-names>R</given-names></name> <etal/></person-group>. <article-title>High-quality brain perfusion SPECT images may be achieved with a high-speed recording using 360 CZT camera</article-title>. <source>EJNMMI Phys</source>. (<year>2020</year>) <volume>7</volume>:<fpage>65</fpage>&#x2013;<lpage>12</lpage>. doi: <pub-id pub-id-type="doi">10.1186/s40658-020-00334-7</pub-id>, PMID: <pub-id pub-id-type="pmid">33146804</pub-id></mixed-citation></ref>
<ref id="ref16"><label>16.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Goshen</surname> <given-names>E</given-names></name> <name><surname>Beilin</surname> <given-names>L</given-names></name> <name><surname>Stern</surname> <given-names>E</given-names></name> <name><surname>Kenig</surname> <given-names>T</given-names></name> <name><surname>Goldkorn</surname> <given-names>R</given-names></name> <name><surname>Ben-Haim</surname> <given-names>S</given-names></name></person-group>. <article-title>Feasibility study of a novel general purpose CZT-based digital SPECT camera: initial clinical results</article-title>. <source>EJNMMI Phys</source>. (<year>2018</year>) <volume>5</volume>:<fpage>6</fpage>&#x2013;<lpage>12</lpage>. doi: <pub-id pub-id-type="doi">10.1186/s40658-018-0205-z</pub-id>, PMID: <pub-id pub-id-type="pmid">29536291</pub-id></mixed-citation></ref>
<ref id="ref17"><label>17.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Verger</surname> <given-names>A</given-names></name> <name><surname>Imbert</surname> <given-names>L</given-names></name> <name><surname>Yagdigul</surname> <given-names>Y</given-names></name> <name><surname>Fay</surname> <given-names>R</given-names></name> <name><surname>Djaballah</surname> <given-names>W</given-names></name> <name><surname>Rouzet</surname> <given-names>F</given-names></name> <etal/></person-group>. <article-title>Factors affecting the myocardial activity acquired during exercise SPECT with a high-sensitivity cardiac CZT camera as compared with conventional anger camera</article-title>. <source>Eur J Nucl Med Mol Imaging</source>. (<year>2014</year>) <volume>41</volume>:<fpage>522</fpage>&#x2013;<lpage>8</lpage>. doi: <pub-id pub-id-type="doi">10.1007/s00259-013-2617-2</pub-id>, PMID: <pub-id pub-id-type="pmid">24202049</pub-id></mixed-citation></ref>
<ref id="ref18"><label>18.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Niimi</surname> <given-names>T</given-names></name> <name><surname>Nanasato</surname> <given-names>M</given-names></name> <name><surname>Sugimoto</surname> <given-names>M</given-names></name> <name><surname>Maeda</surname> <given-names>H</given-names></name></person-group>. <article-title>Evaluation of cadmium-zinc-telluride detector-based single-photon emission computed tomography for nuclear cardiology: a comparison with conventional anger single-photon emission computed tomography</article-title>. <source>Nucl Med Mol Imaging</source>. (<year>2017</year>) <volume>51</volume>:<fpage>331</fpage>&#x2013;<lpage>7</lpage>. doi: <pub-id pub-id-type="doi">10.1007/s13139-017-0474-9</pub-id>, PMID: <pub-id pub-id-type="pmid">29242727</pub-id></mixed-citation></ref>
<ref id="ref19"><label>19.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Washington</surname> <given-names>AL</given-names></name> <name><surname>Teague</surname> <given-names>LC</given-names></name> <name><surname>Duff</surname> <given-names>MC</given-names></name> <name><surname>Burger</surname> <given-names>A</given-names></name> <name><surname>Groza</surname> <given-names>M</given-names></name> <name><surname>Buliga</surname> <given-names>V</given-names></name> <etal/></person-group>. <article-title>The effect of various detector geometries on the performance of CZT using one crystal</article-title>. <source>J Electron Mater</source>. (<year>2011</year>) <volume>40</volume>:<fpage>1744</fpage>&#x2013;<lpage>8</lpage>. doi: <pub-id pub-id-type="doi">10.1007/s11664-011-1675-0</pub-id></mixed-citation></ref>
<ref id="ref20"><label>20.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ben-Haim</surname> <given-names>S</given-names></name> <name><surname>Kennedy</surname> <given-names>J</given-names></name> <name><surname>Keidar</surname> <given-names>Z</given-names></name></person-group>. <article-title>Novel cadmium zinc telluride devices for myocardial perfusion imaging&#x2014;technological aspects and clinical applications</article-title>. <source>Semin Nucl Med</source>. (<year>2016</year>) <volume>46</volume>:<fpage>273</fpage>&#x2013;<lpage>85</lpage>. doi: <pub-id pub-id-type="doi">10.1053/j.semnuclmed.2016.01.002</pub-id>, PMID: <pub-id pub-id-type="pmid">27237438</pub-id></mixed-citation></ref>
<ref id="ref21"><label>21.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ito</surname> <given-names>T</given-names></name> <name><surname>Matsusaka</surname> <given-names>Y</given-names></name> <name><surname>Onoguchi</surname> <given-names>M</given-names></name> <name><surname>Ichikawa</surname> <given-names>H</given-names></name> <name><surname>Okuda</surname> <given-names>K</given-names></name> <name><surname>Shibutani</surname> <given-names>T</given-names></name> <etal/></person-group>. <article-title>Experimental evaluation of the GE NM/CT 870 CZT clinical SPECT system equipped with WEHR and MEHRS collimator</article-title>. <source>J Appl Clin Med Phys</source>. (<year>2021</year>) <volume>22</volume>:<fpage>165</fpage>&#x2013;<lpage>77</lpage>. doi: <pub-id pub-id-type="doi">10.1002/acm2.13158</pub-id>, PMID: <pub-id pub-id-type="pmid">33426812</pub-id></mixed-citation></ref>
<ref id="ref22"><label>22.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Desmonts</surname> <given-names>C</given-names></name> <name><surname>Bouthiba</surname> <given-names>MA</given-names></name> <name><surname>Enilorac</surname> <given-names>B</given-names></name> <name><surname>Nganoa</surname> <given-names>C</given-names></name> <name><surname>Agostini</surname> <given-names>D</given-names></name> <name><surname>Aide</surname> <given-names>N</given-names></name></person-group>. <article-title>Evaluation of a new multipurpose whole-body CZT-based camera: comparison with a dual-head anger camera and first clinical images</article-title>. <source>EJNMMI Phys</source>. (<year>2020</year>) <volume>7</volume>:<fpage>18</fpage>&#x2013;<lpage>6</lpage>. doi: <pub-id pub-id-type="doi">10.1186/s40658-020-0284-5</pub-id>, PMID: <pub-id pub-id-type="pmid">32185566</pub-id></mixed-citation></ref>
<ref id="ref23"><label>23.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Massari</surname> <given-names>R</given-names></name> <name><surname>Mok</surname> <given-names>GSP</given-names></name></person-group>. <article-title>Editorial: new trends in single photon emission computed tomography (SPECT)</article-title>. <source>Front Med</source>. (<year>2023</year>) <volume>10</volume>:<fpage>1349877</fpage>. doi: <pub-id pub-id-type="doi">10.3389/fmed.2023.1349877</pub-id>, PMID: <pub-id pub-id-type="pmid">38179273</pub-id></mixed-citation></ref>
<ref id="ref24"><label>24.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Sun</surname> <given-names>LF</given-names></name> <name><surname>Lv</surname> <given-names>ZL</given-names></name> <name><surname>Hou</surname> <given-names>YS</given-names></name> <name><surname>Liu</surname> <given-names>W</given-names></name> <name><surname>Jiang</surname> <given-names>NM</given-names></name> <name><surname>Liu</surname> <given-names>H</given-names></name> <etal/></person-group>. <article-title>System design and performance evaluation for cardiac SPECT imaging with multi-pinhole collimator</article-title>. <source>At Energy Sci Technol</source>. (<year>2021</year>) <volume>55</volume>:<fpage>407</fpage>&#x2013;<lpage>413</lpage>. doi: <pub-id pub-id-type="doi">10.7538/yzk.2021.zhuankan.0161</pub-id></mixed-citation></ref>
<ref id="ref25"><label>25.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Chen</surname> <given-names>Y</given-names></name> <name><surname>Li</surname> <given-names>JM</given-names></name></person-group>. <article-title>Research progress of CZT-SPECT dedicated myocardial perfusion imaging gate control</article-title>. <source>Med Health Equip</source>. (<year>2021</year>) <volume>42</volume>:<fpage>7</fpage>. doi: <pub-id pub-id-type="doi">10.19745/j.1003-8868.2021107</pub-id></mixed-citation></ref>
<ref id="ref26"><label>26.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Chen</surname> <given-names>Y</given-names></name> <name><surname>Pang</surname> <given-names>ZK</given-names></name> <name><surname>Wang</surname> <given-names>J</given-names></name> <name><surname>Yang</surname> <given-names>X</given-names></name> <name><surname>Li</surname> <given-names>J</given-names></name></person-group>. <article-title>Evaluation of biventricular function by cadmium-zinc-telluride SPECT gated tomographic radionuclide angiography: comparison to conventional SPECT</article-title>. <source>Medicine</source>. (<year>2024</year>) <volume>103</volume>:<fpage>e39821</fpage>. doi: <pub-id pub-id-type="doi">10.1097/MD.0000000000039821</pub-id>, PMID: <pub-id pub-id-type="pmid">39331918</pub-id></mixed-citation></ref>
<ref id="ref27"><label>27.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Murata</surname> <given-names>I</given-names></name> <name><surname>Kusaka</surname> <given-names>S</given-names></name> <name><surname>Minami</surname> <given-names>K</given-names></name> <name><surname>Saraue</surname> <given-names>N</given-names></name> <name><surname>Tamaki</surname> <given-names>S</given-names></name> <name><surname>Kato</surname> <given-names>I</given-names></name> <etal/></person-group>. <article-title>Design of SPECT for BNCT to measure local boron dose with GAGG scintillator</article-title>. <source>Appl Radiat Isot</source>. (<year>2022</year>) <volume>181</volume>:<fpage>110056</fpage>. doi: <pub-id pub-id-type="doi">10.1016/j.apradiso.2021.110056</pub-id>, PMID: <pub-id pub-id-type="pmid">34953318</pub-id></mixed-citation></ref>
<ref id="ref28"><label>28.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Pani</surname> <given-names>R</given-names></name> <name><surname>Pergola</surname> <given-names>A</given-names></name> <name><surname>Bettiol</surname> <given-names>M</given-names></name> <name><surname>Longo</surname> <given-names>M</given-names></name> <name><surname>Polito</surname> <given-names>C</given-names></name> <name><surname>Falconi</surname> <given-names>R</given-names></name> <etal/></person-group>. <article-title>Characterization of monolithic GAGG: Ce coupled to both PMT and SiPM array for gamma imaging in nuclear medicine</article-title>. <source>J Instrum</source>. (<year>2020</year>) <volume>15</volume>:<fpage>C05011</fpage>. doi: <pub-id pub-id-type="doi">10.1088/1748-0221/15/05/C05011</pub-id></mixed-citation></ref>
<ref id="ref29"><label>29.</label><mixed-citation publication-type="book"><person-group person-group-type="author"><name><surname>Liang</surname> <given-names>HC</given-names></name> <name><surname>Ni</surname> <given-names>YC</given-names></name> <name><surname>Wu</surname> <given-names>HN</given-names></name></person-group>. <article-title>Feasibility study of developing a brain-dedicated SPECT scanner</article-title> In: <source>Future trends in biomedical and health informatics and cybersecurity in medical devices: Proceedings of the international conference on biomedical and health informatics, ICBHI 2019, 17&#x2013;20 April 2019, Taipei, Taiwan</source>. <publisher-loc>Cham</publisher-loc>: <publisher-name>Springer International Publishing</publisher-name> (<year>2020</year>). <fpage>143</fpage>&#x2013;<lpage>7</lpage>.</mixed-citation></ref>
<ref id="ref30"><label>30.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Kochurikhin</surname> <given-names>V</given-names></name> <name><surname>Kamada</surname> <given-names>K</given-names></name> <name><surname>Kim</surname> <given-names>K</given-names></name> <name><surname>Ivanov</surname> <given-names>M</given-names></name> <name><surname>Gushchina</surname> <given-names>L</given-names></name> <name><surname>Shoji</surname> <given-names>Y</given-names></name> <etal/></person-group>. <article-title>Czochralski growth of 4-inch diameter Ce:Gd&#x2083;Al&#x2082;Ga&#x2083;O&#x2081;&#x2082; single crystals for scintillator applications</article-title>. <source>J Cryst Growth</source>. (<year>2020</year>) <volume>531</volume>:<fpage>125384</fpage>. doi: <pub-id pub-id-type="doi">10.1016/j.jcrysgro.2019.125384</pub-id></mixed-citation></ref>
<ref id="ref31"><label>31.</label><mixed-citation publication-type="book"><person-group person-group-type="author"><name><surname>Han</surname> <given-names>L</given-names></name> <name><surname>Miller</surname> <given-names>BW</given-names></name> <name><surname>Barber</surname> <given-names>HB</given-names></name> <name><surname>Furenlid</surname> <given-names>LR</given-names></name></person-group>. <article-title>Advances in iQID: upgraded algorithms, thicker scintillators and larger area</article-title> In: <source><italic>2015 IEEE nuclear science symposium and medical imaging conference (NSS/MIC)</italic>; 2015 Oct 31&#x2013;Nov 7; San Diego, CA(USA)</source>. <publisher-loc>Piscataway, NJ</publisher-loc>: <publisher-name>IEEE</publisher-name> (<year>2015</year>). <fpage>1</fpage>&#x2013;<lpage>3</lpage>. doi: <pub-id pub-id-type="doi">10.1109/NSSMIC.2015.7582078</pub-id></mixed-citation></ref>
<ref id="ref32"><label>32.</label><mixed-citation publication-type="other"><person-group person-group-type="author"><name><surname>Han</surname> <given-names>L</given-names></name> <name><surname>Miller</surname> <given-names>BW</given-names></name> <name><surname>Barrett</surname> <given-names>HH</given-names></name> <name><surname>Barber</surname> <given-names>HB</given-names></name> <name><surname>Furenlid</surname> <given-names>LR</given-names></name> <etal/></person-group>. <article-title>Applications of iQID cameras</article-title>. In: <person-group person-group-type="editor"><name><surname>Grim</surname> <given-names>GP</given-names></name> <name><surname>Furenlid</surname> <given-names>LR</given-names></name> <name><surname>Barber</surname> <given-names>HB</given-names></name></person-group>, editors. <source><italic>Radiation detectors in medicine, industry, and National Security XVIII.</italic> Proceedings of SPIE; 2017 Aug 9&#x2013;10; San Diego, CA(USA)</source>. <publisher-loc>Bellingham, WA</publisher-loc>: <publisher-name>SPIE</publisher-name>; (<year>2017</year>). p. <fpage>103930</fpage>. doi:10.1117/12.2279302</mixed-citation></ref>
<ref id="ref33"><label>33.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Pirich</surname> <given-names>C</given-names></name> <name><surname>Keinrath</surname> <given-names>P</given-names></name> <name><surname>Barth</surname> <given-names>G</given-names></name> <name><surname>Rendl</surname> <given-names>G</given-names></name> <name><surname>Rettenbacher</surname> <given-names>L</given-names></name> <name><surname>Rodrigues</surname> <given-names>M</given-names></name></person-group>. <article-title>Diagnostic accuracy and functional parameters of myocardial perfusion scintigraphy using accelerated cardiac acquisition with IQ SPECT technique in comparison to conventional imaging</article-title>. <source>Q J Nucl Med Mol Imaging</source>. (<year>2017</year>) <volume>61</volume>:<fpage>102</fpage>&#x2013;<lpage>7</lpage>. doi: <pub-id pub-id-type="doi">10.23736/S1824-4785.16.02703-5</pub-id>, PMID: <pub-id pub-id-type="pmid">24975843</pub-id></mixed-citation></ref>
<ref id="ref34"><label>34.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Hayder</surname> <given-names>A</given-names></name> <name><surname>Bayram</surname> <given-names>T</given-names></name> <name><surname>Gedik</surname> <given-names>S</given-names></name> <name><surname>S&#x00F6;nmez</surname> <given-names>B</given-names></name> <name><surname>Duman</surname> <given-names>P</given-names></name> <name><surname>Yavruo&#x011F;lu</surname> <given-names>C</given-names></name></person-group>. <article-title>Intrinsic performance parameters assessment of various scintillation crystals for a SPECT gamma camera</article-title>. <source>Nucl Instrum Methods Phys Res A</source>. (<year>2025</year>) <volume>1076</volume>:<fpage>170447</fpage>. doi: <pub-id pub-id-type="doi">10.1016/j.nima.2025.170447</pub-id></mixed-citation></ref>
<ref id="ref35"><label>35.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ivashchenko</surname> <given-names>O</given-names></name> <name><surname>Van Der Have</surname> <given-names>F</given-names></name> <name><surname>Villena</surname> <given-names>JL</given-names></name> <name><surname>Groen</surname> <given-names>HC</given-names></name> <name><surname>Ramakers</surname> <given-names>RM</given-names></name> <name><surname>Weinans</surname> <given-names>HH</given-names></name> <etal/></person-group>. <article-title>Quarter-millimeter-resolution molecular mouse imaging with U-SPECT+</article-title>. <source>Mol Imaging</source>. (<year>2015</year>) <volume>14</volume>:<fpage>7290.2014.00053</fpage>. doi: <pub-id pub-id-type="doi">10.2310/7290.2014.00053</pub-id>, PMID: <pub-id pub-id-type="pmid">25429783</pub-id></mixed-citation></ref>
<ref id="ref36"><label>36.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Hoffmann</surname> <given-names>JV</given-names></name> <name><surname>Janssen</surname> <given-names>JP</given-names></name> <name><surname>Kanno</surname> <given-names>T</given-names></name> <name><surname>Shibutani</surname> <given-names>T</given-names></name> <name><surname>Onoguchi</surname> <given-names>M</given-names></name> <name><surname>Lapa</surname> <given-names>C</given-names></name> <etal/></person-group>. <article-title>Performance evaluation of fifth-generation ultra-high-resolution SPECT system with two stationary detectors and multi-pinhole imaging</article-title>. <source>EJNMMI Phys</source>. (<year>2020</year>) <volume>7</volume>:<fpage>64</fpage>&#x2013;<lpage>15</lpage>. doi: <pub-id pub-id-type="doi">10.1186/s40658-020-00335-6</pub-id>, PMID: <pub-id pub-id-type="pmid">33140263</pub-id></mixed-citation></ref>
<ref id="ref37"><label>37.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Chen</surname> <given-names>Y</given-names></name> <name><surname>Goorden</surname> <given-names>MC</given-names></name> <name><surname>Vastenhouw</surname> <given-names>B</given-names></name> <name><surname>Beekman</surname> <given-names>FJ</given-names></name></person-group>. <article-title>Optimized sampling for high resolution multi-pinhole brain SPECT with stationary detectors</article-title>. <source>Phys Med Biol</source>. (<year>2020</year>) <volume>65</volume>:<fpage>015002</fpage>. doi: <pub-id pub-id-type="doi">10.1088/1361-6560/ab5bc6</pub-id>, PMID: <pub-id pub-id-type="pmid">31770743</pub-id></mixed-citation></ref>
<ref id="ref38"><label>38.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ozsahin</surname> <given-names>I</given-names></name> <name><surname>Chen</surname> <given-names>L</given-names></name> <name><surname>K&#x00F6;nik</surname> <given-names>A</given-names></name> <name><surname>King</surname> <given-names>MA</given-names></name> <name><surname>Beekman</surname> <given-names>FJ</given-names></name> <name><surname>Mok</surname> <given-names>GSP</given-names></name></person-group>. <article-title>The clinical utilities of multi-pinhole single photon emission computed tomography</article-title>. <source>Quant Imaging Med Surg</source>. (<year>2020</year>) <volume>10</volume>:<fpage>2006</fpage>&#x2013;<lpage>29</lpage>. doi: <pub-id pub-id-type="doi">10.21037/qims-19-1036</pub-id>, PMID: <pub-id pub-id-type="pmid">33014732</pub-id></mixed-citation></ref>
<ref id="ref39"><label>39.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Lai</surname> <given-names>X</given-names></name> <name><surname>Meng</surname> <given-names>LJ</given-names></name></person-group>. <article-title>Simulation study of the second-generation MR-compatible SPECT system based on the inverted compound-eye gamma camera design</article-title>. <source>Phys Med Biol</source>. (<year>2018</year>) <volume>63</volume>:<fpage>045008</fpage>. doi: <pub-id pub-id-type="doi">10.1088/1361-6560/aaa4fb</pub-id>, PMID: <pub-id pub-id-type="pmid">29298960</pub-id></mixed-citation></ref>
<ref id="ref40"><label>40.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Miller</surname> <given-names>BW</given-names></name> <name><surname>Gregory</surname> <given-names>SJ</given-names></name> <name><surname>Fuller</surname> <given-names>ES</given-names></name> <name><surname>Barrett</surname> <given-names>HH</given-names></name> <name><surname>Bradford Barber</surname> <given-names>H</given-names></name> <name><surname>Furenlid</surname> <given-names>LR</given-names></name></person-group>. <article-title>The iQID camera: an ionizing-radiation quantum imaging detector</article-title>. <source>Nucl Instrum Methods Phys Res A.</source> (<year>2014</year>) <volume>767</volume>:<fpage>146</fpage>&#x2013;<lpage>52</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.nima.2014.05.070</pub-id>, PMID: <pub-id pub-id-type="pmid">26166921</pub-id></mixed-citation></ref>
<ref id="ref41"><label>41.</label><mixed-citation publication-type="book"><person-group person-group-type="author"><name><surname>Han</surname> <given-names>L</given-names></name> <name><surname>Caucci</surname> <given-names>L</given-names></name> <name><surname>Miller</surname> <given-names>BW</given-names></name> <name><surname>Barrett</surname> <given-names>HH</given-names></name> <name><surname>Woolfenden</surname> <given-names>JM</given-names></name> <name><surname>Furenlid</surname> <given-names>LR</given-names></name> <etal/></person-group>. <article-title>System calibration for FastSPECT III: an ultra-high resolution CCD-based pinhole SPECT system</article-title> In: <source>2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).</source> <publisher-loc>Piscataway, NJ</publisher-loc>: <publisher-name>IEEE</publisher-name> (<year>2017</year>): <fpage>1</fpage>&#x2013;<lpage>3</lpage>.</mixed-citation></ref>
<ref id="ref42"><label>42.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Barhoum</surname> <given-names>A</given-names></name> <name><surname>Tahtali</surname> <given-names>M</given-names></name> <name><surname>Guatelli</surname> <given-names>S</given-names></name> <name><surname>Camattari</surname> <given-names>R</given-names></name> <name><surname>Miroshnichenko</surname> <given-names>A</given-names></name></person-group>. <article-title>Feasibility study of multi Laue lens based SPECT with a dedicated 3D reconstruction algorithm using Monte Carlo simulations</article-title>. <source>Sci Rep</source>. (<year>2025</year>) <volume>15</volume>:<fpage>13339</fpage>. doi: <pub-id pub-id-type="doi">10.1038/s41598-025-85955-7</pub-id>, PMID: <pub-id pub-id-type="pmid">40246994</pub-id></mixed-citation></ref>
<ref id="ref43"><label>43.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Leube</surname> <given-names>J</given-names></name> <name><surname>Claeys</surname> <given-names>W</given-names></name> <name><surname>Gustafsson</surname> <given-names>J</given-names></name> <name><surname>Salas-Ramirez</surname> <given-names>M</given-names></name> <name><surname>Lassmann</surname> <given-names>M</given-names></name> <name><surname>Koole</surname> <given-names>M</given-names></name> <etal/></person-group>. <article-title>Position dependence of recovery coefficients in <sup>177</sup>Lu-SPECT/CT reconstructions: phantom simulations and measurements</article-title>. <source>EJNMMI Phys</source>. (<year>2024</year>) <volume>11</volume>:<fpage>52</fpage>. doi: <pub-id pub-id-type="doi">10.1186/s40658-024-00662-y</pub-id>, PMID: <pub-id pub-id-type="pmid">38937408</pub-id></mixed-citation></ref>
<ref id="ref44"><label>44.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Cheng</surname> <given-names>ZB</given-names></name> <name><surname>Chen</surname> <given-names>P</given-names></name> <name><surname>Yan</surname> <given-names>JH</given-names></name></person-group>. <article-title>A review of state-of-the-art resolution improvement techniques in SPECT imaging</article-title>. <source>EJNMMI Phys</source>. (<year>2025</year>) <volume>12</volume>:<fpage>9</fpage>. doi: <pub-id pub-id-type="doi">10.1186/s40658-025-00724-9</pub-id>, PMID: <pub-id pub-id-type="pmid">39883257</pub-id></mixed-citation></ref>
<ref id="ref45"><label>45.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Sensakovic</surname> <given-names>WF</given-names></name> <name><surname>Hough</surname> <given-names>MC</given-names></name> <name><surname>Kimbley</surname> <given-names>EA</given-names></name></person-group>. <article-title>ACR testing of a dedicated head SPECT unit</article-title>. <source>J Appl Clin Med Phys</source>. (<year>2014</year>) <volume>15</volume>:<fpage>1</fpage>&#x2013;<lpage>10</lpage>. doi: <pub-id pub-id-type="doi">10.1120/jacmp.v15i4.4632</pub-id>, PMID: <pub-id pub-id-type="pmid">25207395</pub-id></mixed-citation></ref>
<ref id="ref46"><label>46.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Stam</surname> <given-names>MK</given-names></name> <name><surname>Verwer</surname> <given-names>EE</given-names></name> <name><surname>Booij</surname> <given-names>J</given-names></name> <name><surname>Adriaanse</surname> <given-names>SM</given-names></name> <name><surname>de Bruin</surname> <given-names>CM</given-names></name> <name><surname>de Wit</surname> <given-names>TC</given-names></name></person-group>. <article-title>Performance evaluation of a novel brain-dedicated SPECT system</article-title>. <source>EJNMMI Phys</source>. (<year>2018</year>) <volume>5</volume>:<fpage>4</fpage>&#x2013;<lpage>14</lpage>. doi: <pub-id pub-id-type="doi">10.1186/s40658-018-0203-1</pub-id>, PMID: <pub-id pub-id-type="pmid">29492787</pub-id></mixed-citation></ref>
<ref id="ref47"><label>47.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Delso</surname> <given-names>G</given-names></name> <name><surname>F&#x00FC;rst</surname> <given-names>S</given-names></name> <name><surname>Jakoby</surname> <given-names>B</given-names></name> <name><surname>Ladebeck</surname> <given-names>R</given-names></name> <name><surname>Ganter</surname> <given-names>C</given-names></name> <name><surname>Nekolla</surname> <given-names>SG</given-names></name> <etal/></person-group>. <article-title>Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner</article-title>. <source>J Nucl Med</source>. (<year>2011</year>) <volume>52</volume>:<fpage>1914</fpage>&#x2013;<lpage>22</lpage>. doi: <pub-id pub-id-type="doi">10.2967/jnumed.111.092726</pub-id>, PMID: <pub-id pub-id-type="pmid">22080447</pub-id></mixed-citation></ref>
<ref id="ref48"><label>48.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Unterrainer</surname> <given-names>M</given-names></name> <name><surname>Eze</surname> <given-names>C</given-names></name> <name><surname>Ilhan</surname> <given-names>H</given-names></name> <name><surname>Marschner</surname> <given-names>S</given-names></name> <name><surname>Roengvoraphoj</surname> <given-names>O</given-names></name> <name><surname>Schmidt-Hegemann</surname> <given-names>NS</given-names></name> <etal/></person-group>. <article-title>Recent advances of PET imaging in clinical radiation oncology</article-title>. <source>Radiat Oncol</source>. (<year>2020</year>) <volume>15</volume>:<fpage>88</fpage>&#x2013;<lpage>15</lpage>. doi: <pub-id pub-id-type="doi">10.1186/s13014-020-01519-1</pub-id>, PMID: <pub-id pub-id-type="pmid">32317029</pub-id></mixed-citation></ref>
<ref id="ref49"><label>49.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Gu</surname> <given-names>Y</given-names></name> <name><surname>Matteson</surname> <given-names>JL</given-names></name> <name><surname>Skelton</surname> <given-names>RT</given-names></name> <name><surname>Deal</surname> <given-names>AC</given-names></name> <name><surname>Stephan</surname> <given-names>EA</given-names></name> <name><surname>Duttweiler</surname> <given-names>F</given-names></name> <etal/></person-group>. <article-title>Study of a high-resolution, 3D positioning cadmium zinc telluride detector for PET</article-title>. <source>Phys Med Biol</source>. (<year>2011</year>) <volume>56</volume>:<fpage>1563</fpage>&#x2013;<lpage>84</lpage>. doi: <pub-id pub-id-type="doi">10.1088/0031-9155/56/6/004</pub-id>, PMID: <pub-id pub-id-type="pmid">21335649</pub-id></mixed-citation></ref>
<ref id="ref50"><label>50.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Tomiyama</surname> <given-names>T</given-names></name> <name><surname>Ishihara</surname> <given-names>K</given-names></name> <name><surname>Suda</surname> <given-names>M</given-names></name> <name><surname>Kanaya</surname> <given-names>K</given-names></name> <name><surname>Sakurai</surname> <given-names>M</given-names></name> <name><surname>Takahashi</surname> <given-names>N</given-names></name> <etal/></person-group>. <article-title>Impact of time-of-flight on qualitative and quantitative analyses of myocardial perfusion PET studies using <sup>13</sup>N-ammonia</article-title>. <source>J Nucl Cardiol</source>. (<year>2015</year>) <volume>22</volume>:<fpage>998</fpage>&#x2013;<lpage>1007</lpage>. doi: <pub-id pub-id-type="doi">10.1007/s12350-014-0037-8</pub-id>, PMID: <pub-id pub-id-type="pmid">25467250</pub-id></mixed-citation></ref>
<ref id="ref51"><label>51.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Bettinardi</surname> <given-names>V</given-names></name> <name><surname>Presotto</surname> <given-names>L</given-names></name> <name><surname>Rapisarda</surname> <given-names>E</given-names></name> <name><surname>Picchio</surname> <given-names>M</given-names></name> <name><surname>Gianolli</surname> <given-names>L</given-names></name> <name><surname>Gilardi</surname> <given-names>MC</given-names></name></person-group>. <article-title>Physical performance of the new hybrid PET/CT Discovery-690</article-title>. <source>Med Phys</source>. (<year>2011</year>) <volume>38</volume>:<fpage>5394</fpage>&#x2013;<lpage>411</lpage>. doi: <pub-id pub-id-type="doi">10.1118/1.3635220</pub-id>, PMID: <pub-id pub-id-type="pmid">21992359</pub-id></mixed-citation></ref>
<ref id="ref52"><label>52.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Lois</surname> <given-names>C</given-names></name> <name><surname>Jakoby</surname> <given-names>BW</given-names></name> <name><surname>Long</surname> <given-names>MJ</given-names></name> <name><surname>Hubner</surname> <given-names>KF</given-names></name> <name><surname>Barker</surname> <given-names>DW</given-names></name> <name><surname>Casey</surname> <given-names>ME</given-names></name> <etal/></person-group>. <article-title>An assessment of the impact of incorporating time-of-flight information into clinical PET/CT imaging</article-title>. <source>J Nucl Med</source>. (<year>2010</year>) <volume>51</volume>:<fpage>237</fpage>&#x2013;<lpage>45</lpage>. doi: <pub-id pub-id-type="doi">10.2967/jnumed.109.068098</pub-id>, PMID: <pub-id pub-id-type="pmid">20080882</pub-id></mixed-citation></ref>
<ref id="ref53"><label>53.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ren</surname> <given-names>ZM</given-names></name> <name><surname>Sidky</surname> <given-names>EY</given-names></name> <name><surname>Barber</surname> <given-names>RF</given-names></name> <name><surname>Kao</surname> <given-names>CM</given-names></name> <name><surname>Pan</surname> <given-names>X</given-names></name></person-group>. <article-title>Simultaneous activity and attenuation estimation in TOF-PET with TV-constrained nonconvex optimization</article-title>. <source>IEEE Trans Med Imaging</source>. (<year>2024</year>) <volume>43</volume>:<fpage>2347</fpage>&#x2013;<lpage>57</lpage>. doi: <pub-id pub-id-type="doi">10.1109/TMI.2024.3365302</pub-id>, PMID: <pub-id pub-id-type="pmid">38354078</pub-id></mixed-citation></ref>
<ref id="ref54"><label>54.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Kwon</surname> <given-names>SI</given-names></name> <name><surname>Ota</surname> <given-names>R</given-names></name> <name><surname>Berg</surname> <given-names>E</given-names></name> <name><surname>Hashimoto</surname> <given-names>F</given-names></name> <name><surname>Nakajima</surname> <given-names>K</given-names></name> <name><surname>Ogawa</surname> <given-names>I</given-names></name> <etal/></person-group>. <article-title>Ultrafast timing enables reconstruction-free positron emission imaging</article-title>. <source>Nat Photonics</source>. (<year>2021</year>) <volume>15</volume>:<fpage>914</fpage>&#x2013;<lpage>8</lpage>. doi: <pub-id pub-id-type="doi">10.1038/s41566-021-00871-2</pub-id>, PMID: <pub-id pub-id-type="pmid">35663419</pub-id></mixed-citation></ref>
<ref id="ref55"><label>55.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Aide</surname> <given-names>N</given-names></name> <name><surname>Lasnon</surname> <given-names>C</given-names></name> <name><surname>Kesner</surname> <given-names>A</given-names></name> <name><surname>Levin</surname> <given-names>CS</given-names></name> <name><surname>Buvat</surname> <given-names>I</given-names></name> <name><surname>Iagaru</surname> <given-names>A</given-names></name> <etal/></person-group>. <article-title>New PET technologies&#x2013;embracing progress and pushing the limits</article-title>. <source>Eur J Nucl Med Mol Imaging</source>. (<year>2021</year>) <volume>48</volume>:<fpage>2711</fpage>&#x2013;<lpage>26</lpage>. doi: <pub-id pub-id-type="doi">10.1007/s00259-021-05390-4</pub-id>, PMID: <pub-id pub-id-type="pmid">34081153</pub-id></mixed-citation></ref>
<ref id="ref56"><label>56.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>L&#x00F3;pez-Mora</surname> <given-names>DA</given-names></name> <name><surname>Flotats</surname> <given-names>A</given-names></name> <name><surname>Fuentes-Ocampo</surname> <given-names>F</given-names></name> <name><surname>Camacho</surname> <given-names>V</given-names></name> <name><surname>Fern&#x00E1;ndez</surname> <given-names>A</given-names></name> <name><surname>Ruiz</surname> <given-names>A</given-names></name> <etal/></person-group>. <article-title>Comparison of image quality and lesion detection between digital and analog PET/CT</article-title>. <source>Eur J Nucl Med Mol Imaging</source>. (<year>2019</year>) <volume>46</volume>:<fpage>1383</fpage>&#x2013;<lpage>90</lpage>. doi: <pub-id pub-id-type="doi">10.1007/s00259-019-4260-z</pub-id>, PMID: <pub-id pub-id-type="pmid">30631910</pub-id></mixed-citation></ref>
<ref id="ref57"><label>57.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Tsutsui</surname> <given-names>Y</given-names></name> <name><surname>Awamoto</surname> <given-names>S</given-names></name> <name><surname>Himuro</surname> <given-names>K</given-names></name> <name><surname>Kato</surname> <given-names>T</given-names></name> <name><surname>Baba</surname> <given-names>S</given-names></name> <name><surname>Sasaki</surname> <given-names>M</given-names></name></person-group>. <article-title>Evaluating and comparing the image quality and quantification accuracy of SiPM-PET/CT and PMT-PET/CT</article-title>. <source>Ann Nucl Med</source>. (<year>2020</year>) <volume>34</volume>:<fpage>725</fpage>&#x2013;<lpage>35</lpage>. doi: <pub-id pub-id-type="doi">10.1007/s12149-020-01496-1</pub-id>, PMID: <pub-id pub-id-type="pmid">32621167</pub-id></mixed-citation></ref>
<ref id="ref58"><label>58.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Pourashraf</surname> <given-names>S</given-names></name> <name><surname>Gonzalez-Montoro</surname> <given-names>A</given-names></name> <name><surname>Won</surname> <given-names>JY</given-names></name> <name><surname>Lee</surname> <given-names>MS</given-names></name> <name><surname>Cates</surname> <given-names>JW</given-names></name> <name><surname>Zhao</surname> <given-names>Z</given-names></name> <etal/></person-group>. <article-title>Scalable electronic readout design for a 100 ps coincidence time resolution TOF-PET system</article-title>. <source>Phys Med Biol</source>. (<year>2021</year>) <volume>66</volume>:<fpage>085005</fpage>. doi: <pub-id pub-id-type="doi">10.1088/1361-6560/abf1bc</pub-id>, PMID: <pub-id pub-id-type="pmid">33761476</pub-id></mixed-citation></ref>
<ref id="ref59"><label>59.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Van Dam</surname> <given-names>HT</given-names></name> <name><surname>Seifert</surname> <given-names>S</given-names></name> <name><surname>Schaart</surname> <given-names>DR</given-names></name></person-group>. <article-title>The statistical distribution of the number of counted scintillation photons in digital silicon photomultipliers: model and validation</article-title>. <source>Phys Med Biol</source>. (<year>2012</year>) <volume>57</volume>:<fpage>4885</fpage>&#x2013;<lpage>903</lpage>. doi: <pub-id pub-id-type="doi">10.1088/0031-9155/57/15/4885</pub-id>, PMID: <pub-id pub-id-type="pmid">22796633</pub-id></mixed-citation></ref>
<ref id="ref60"><label>60.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Efthimiou</surname> <given-names>N</given-names></name> <name><surname>Kratochwil</surname> <given-names>N</given-names></name> <name><surname>Gundacker</surname> <given-names>S</given-names></name> <name><surname>Polesel</surname> <given-names>A</given-names></name> <name><surname>Salomoni</surname> <given-names>M</given-names></name> <name><surname>Auffray</surname> <given-names>E</given-names></name> <etal/></person-group>. <article-title>TOF-PET image reconstruction with multiple timing kernels applied on Cherenkov radiation in BGO</article-title>. <source>IEEE Trans Radiat Plasma Med Sci</source>. (<year>2020</year>) <volume>5</volume>:<fpage>703</fpage>&#x2013;<lpage>11</lpage>. doi: <pub-id pub-id-type="doi">10.1109/TRPMS.2020.3048642</pub-id>, PMID: <pub-id pub-id-type="pmid">34541434</pub-id></mixed-citation></ref>
<ref id="ref61"><label>61.</label><mixed-citation publication-type="other"><person-group person-group-type="author"><name><surname>Ishikawa</surname> <given-names>T</given-names></name> <name><surname>Akamatsu</surname> <given-names>G</given-names></name> <name><surname>Tashima</surname> <given-names>H</given-names></name> <name><surname>Nishikido</surname> <given-names>F</given-names></name> <name><surname>Hashimoto</surname> <given-names>F</given-names></name> <name><surname>Ota</surname> <given-names>R</given-names></name> <etal/></person-group>. Imaging simulation of a dual-panel PET geometry with ultrafast TOF detectors. <italic>arXiv</italic> [Preprint]. <italic>arXiv:2502.01006</italic>. (<year>2025</year>). doi:<pub-id pub-id-type="doi">10.48550/arXiv.2502.01006</pub-id></mixed-citation></ref>
<ref id="ref62"><label>62.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Zabihi</surname> <given-names>A</given-names></name> <name><surname>Li</surname> <given-names>XR</given-names></name> <name><surname>Ramirez</surname> <given-names>A</given-names></name> <name><surname>Ahmad</surname> <given-names>I</given-names></name> <name><surname>da Rocha Rolo</surname> <given-names>MD</given-names></name> <name><surname>Franco</surname> <given-names>D</given-names></name> <etal/></person-group>. <article-title>3D&#x03C0;: three-dimensional positron imaging, a novel total-body PET scanner using xenon-doped liquid argon scintillator</article-title>. <source>Phys Med Biol</source>. (<year>2025</year>) <volume>70</volume>:<fpage>065015</fpage>. doi: <pub-id pub-id-type="doi">10.1088/1361-6560/adbaac</pub-id>, PMID: <pub-id pub-id-type="pmid">40009985</pub-id></mixed-citation></ref>
<ref id="ref63"><label>63.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Gu</surname> <given-names>Z</given-names></name> <name><surname>Taschereau</surname> <given-names>R</given-names></name> <name><surname>Vu</surname> <given-names>NT</given-names></name> <name><surname>Prout</surname> <given-names>DL</given-names></name> <name><surname>Silverman</surname> <given-names>RW</given-names></name> <name><surname>Lee</surname> <given-names>JT</given-names></name> <etal/></person-group>. <article-title>Performance evaluation of G8, a high-sensitivity benchtop preclinical PET/CT tomograph</article-title>. <source>J Nucl Med</source>. (<year>2019</year>) <volume>60</volume>:<fpage>142</fpage>&#x2013;<lpage>9</lpage>. doi: <pub-id pub-id-type="doi">10.2967/jnumed.118.208827</pub-id>, PMID: <pub-id pub-id-type="pmid">29903933</pub-id></mixed-citation></ref>
<ref id="ref64"><label>64.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Chang</surname> <given-names>CM</given-names></name> <name><surname>Cates</surname> <given-names>JW</given-names></name> <name><surname>Levin</surname> <given-names>CS</given-names></name></person-group>. <article-title>Time-over-threshold for pulse shape discrimination in a time-of-flight phoswich PET detector</article-title>. <source>Phys Med Biol</source>. (<year>2017</year>) <volume>62</volume>:<fpage>258</fpage>&#x2013;<lpage>71</lpage>. doi: <pub-id pub-id-type="doi">10.1088/1361-6560/62/1/258</pub-id>, PMID: <pub-id pub-id-type="pmid">27991437</pub-id></mixed-citation></ref>
<ref id="ref65"><label>65.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Wei</surname> <given-names>QY</given-names></name> <name><surname>Xu</surname> <given-names>TP</given-names></name> <name><surname>Dai</surname> <given-names>TT</given-names></name> <name><surname>Wang</surname> <given-names>S</given-names></name> <name><surname>Liu</surname> <given-names>YQ</given-names></name> <name><surname>Gu</surname> <given-names>Y</given-names></name> <etal/></person-group>. <article-title>Development of a compact DOI&#x2013;TOF detector module for high-performance PET systems</article-title>. <source>Nucl Sci Tech</source>. (<year>2017</year>) <volume>28</volume>:<fpage>43</fpage>. doi: <pub-id pub-id-type="doi">10.1007/s41365-017-0202-2</pub-id></mixed-citation></ref>
<ref id="ref66"><label>66.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Kuang</surname> <given-names>Z</given-names></name> <name><surname>Yang</surname> <given-names>Q</given-names></name> <name><surname>Wang</surname> <given-names>X</given-names></name> <name><surname>Fu</surname> <given-names>X</given-names></name> <name><surname>Ren</surname> <given-names>N</given-names></name> <name><surname>Wu</surname> <given-names>S</given-names></name> <etal/></person-group>. <article-title>Performance of a depth encoding PET detector module using light sharing and single-ended readout with SiPMs</article-title>. <source>Phys Med Biol</source>. (<year>2019</year>) <volume>64</volume>:<fpage>085012</fpage>. doi: <pub-id pub-id-type="doi">10.1088/1361-6560/ab1152</pub-id>, PMID: <pub-id pub-id-type="pmid">30893674</pub-id></mixed-citation></ref>
<ref id="ref67"><label>67.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Fan</surname> <given-names>P</given-names></name> <name><surname>Ma</surname> <given-names>TY</given-names></name> <name><surname>Wei</surname> <given-names>QY</given-names></name> <name><surname>Yao</surname> <given-names>R</given-names></name> <name><surname>Liu</surname> <given-names>Y</given-names></name> <name><surname>Wang</surname> <given-names>S</given-names></name></person-group>. <article-title>Choice of crystal surface finishing for a dual-ended readout depth-of-interaction (DOI) detector</article-title>. <source>Phys Med Biol</source>. (<year>2016</year>) <volume>61</volume>:<fpage>1041</fpage>&#x2013;<lpage>56</lpage>. doi: <pub-id pub-id-type="doi">10.1088/0031-9155/61/3/1041</pub-id>, PMID: <pub-id pub-id-type="pmid">26757857</pub-id></mixed-citation></ref>
<ref id="ref68"><label>68.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Kuang</surname> <given-names>Z</given-names></name> <name><surname>Sang</surname> <given-names>Z</given-names></name> <name><surname>Wang</surname> <given-names>X</given-names></name> <name><surname>Fu</surname> <given-names>X</given-names></name> <name><surname>Ren</surname> <given-names>N</given-names></name> <name><surname>Zhang</surname> <given-names>X</given-names></name> <etal/></person-group>. <article-title>Development of depth encoding small animal PET detectors using dual-ended readout of pixelated scintillator arrays with SiPMs</article-title>. <source>Med Phys</source>. (<year>2018</year>) <volume>45</volume>:<fpage>613</fpage>&#x2013;<lpage>21</lpage>. doi: <pub-id pub-id-type="doi">10.1002/mp.12722</pub-id>, PMID: <pub-id pub-id-type="pmid">29222959</pub-id></mixed-citation></ref>
<ref id="ref69"><label>69.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Binder</surname> <given-names>T</given-names></name> <name><surname>Kang</surname> <given-names>HG</given-names></name> <name><surname>Nitta</surname> <given-names>M</given-names></name> <name><surname>Schneider</surname> <given-names>F</given-names></name> <name><surname>Yamaya</surname> <given-names>T</given-names></name> <name><surname>Parodi</surname> <given-names>K</given-names></name> <etal/></person-group>. <article-title>Performance evaluation of a staggered three-layer DOI PET detector using a 1 mm LYSO pitch with PETsys TOFPET2 ASIC: comparison of HAMAMATSU and KETEK SiPMs</article-title>. <source>Phys Med Biol</source>. (<year>2021</year>) <volume>66</volume>:<fpage>125016</fpage>. doi: <pub-id pub-id-type="doi">10.1088/1361-6560/abfbf3</pub-id>, PMID: <pub-id pub-id-type="pmid">33906179</pub-id></mixed-citation></ref>
<ref id="ref70"><label>70.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ullah</surname> <given-names>MN</given-names></name> <name><surname>Pratiwi</surname> <given-names>E</given-names></name> <name><surname>Park</surname> <given-names>JH</given-names></name> <name><surname>Lee</surname> <given-names>K</given-names></name> <name><surname>Choi</surname> <given-names>H</given-names></name> <name><surname>Yeom</surname> <given-names>JY</given-names></name></person-group>. <article-title>Wavelength discrimination (WLD) TOF-PET detector with DOI information</article-title>. <source>Phys Med Biol</source>. (<year>2020</year>) <volume>65</volume>:<fpage>055003</fpage>. doi: <pub-id pub-id-type="doi">10.1088/1361-6560/ab6579</pub-id>, PMID: <pub-id pub-id-type="pmid">31874462</pub-id></mixed-citation></ref>
<ref id="ref71"><label>71.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Du</surname> <given-names>JW</given-names></name> <name><surname>Jones</surname> <given-names>T</given-names></name></person-group>. <article-title>Technical opportunities and challenges in developing total-body PET scanners for mice and rats</article-title>. <source>EJNMMI Phys</source>. (<year>2023</year>) <volume>10</volume>:<fpage>2</fpage>. doi: <pub-id pub-id-type="doi">10.1186/s40658-022-00523-6</pub-id>, PMID: <pub-id pub-id-type="pmid">37367964</pub-id></mixed-citation></ref>
<ref id="ref72"><label>72.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Kuang</surname> <given-names>ZH</given-names></name> <name><surname>Sang</surname> <given-names>ZR</given-names></name> <name><surname>Ren</surname> <given-names>N</given-names></name> <name><surname>Wang</surname> <given-names>X</given-names></name> <name><surname>Zeng</surname> <given-names>T</given-names></name> <name><surname>Wu</surname> <given-names>S</given-names></name> <etal/></person-group>. <article-title>Development and performance of SIAT bPET: a high-resolution and high-sensitivity MR-compatible brain PET scanner using dual-ended readout detectors</article-title>. <source>Eur J Nucl Med Mol Imaging</source>. (<year>2024</year>) <volume>51</volume>:<fpage>346</fpage>&#x2013;<lpage>57</lpage>. doi: <pub-id pub-id-type="doi">10.1007/s00259-023-06458-z</pub-id>, PMID: <pub-id pub-id-type="pmid">37782321</pub-id></mixed-citation></ref>
<ref id="ref73"><label>73.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Zeng</surname> <given-names>XJ</given-names></name> <name><surname>Wang</surname> <given-names>ZP</given-names></name> <name><surname>Tan</surname> <given-names>WB</given-names></name> <name><surname>Petersen</surname> <given-names>E</given-names></name> <name><surname>Cao</surname> <given-names>X</given-names></name> <name><surname>LaBella</surname> <given-names>A</given-names></name> <etal/></person-group>. <article-title>A conformal TOF&#x2013;DOI prism-PET prototype scanner for high-resolution quantitative neuroimaging</article-title>. <source>Med Phys</source>. (<year>2023</year>) <volume>50</volume>:<fpage>3401</fpage>&#x2013;<lpage>17</lpage>. doi: <pub-id pub-id-type="doi">10.1002/mp.16223</pub-id>, PMID: <pub-id pub-id-type="pmid">36651630</pub-id></mixed-citation></ref>
<ref id="ref74"><label>74.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Watanabe</surname> <given-names>M</given-names></name> <name><surname>Saito</surname> <given-names>A</given-names></name> <name><surname>Isobe</surname> <given-names>T</given-names></name> <name><surname>Ote</surname> <given-names>K</given-names></name> <name><surname>Yamada</surname> <given-names>R</given-names></name> <name><surname>Moriya</surname> <given-names>T</given-names></name> <etal/></person-group>. <article-title>Performance evaluation of a high-resolution brain PET scanner using four-layer MPPC DOI detectors</article-title>. <source>Phys Med Biol</source>. (<year>2017</year>) <volume>62</volume>:<fpage>7148</fpage>&#x2013;<lpage>66</lpage>. doi: <pub-id pub-id-type="doi">10.1088/1361-6560/aa82e8</pub-id>, PMID: <pub-id pub-id-type="pmid">28753133</pub-id></mixed-citation></ref>
<ref id="ref75"><label>75.</label><mixed-citation publication-type="book"><person-group person-group-type="author"><name><surname>Barrio</surname> <given-names>J</given-names></name> <name><surname>Cucarella</surname> <given-names>N</given-names></name> <name><surname>Freire</surname> <given-names>M</given-names></name> <name><surname>Lamprou</surname> <given-names>E</given-names></name> <name><surname>Aguilar</surname> <given-names>S</given-names></name> <name><surname>Valladares</surname> <given-names>C</given-names></name> <etal/></person-group>. <article-title>PET detector based on a semi-monolithic crystal with DOI and TOF capabilities</article-title> In: <source>IEEE nuclear science symposium and medical imaging conference (NSS/MIC) Boston, MA, USA: IEEE</source>, (<year>2020</year>), <fpage>1</fpage>&#x2013;<lpage>3</lpage>.</mixed-citation></ref>
<ref id="ref76"><label>76.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Jiang</surname> <given-names>J</given-names></name> <name><surname>Hua</surname> <given-names>J</given-names></name> <name><surname>Wang</surname> <given-names>H</given-names></name> <name><surname>Yuan</surname> <given-names>Z</given-names></name> <name><surname>Meng</surname> <given-names>Y</given-names></name> <name><surname>Lu</surname> <given-names>H</given-names></name> <etal/></person-group>. <article-title>A virtual-pinhole PET device for improving contrast recovery and enhancing lesion detectability of a one-meter-long PET scanner: a simulation study</article-title>. <source>Phys Med Biol</source>. (<year>2023</year>) <volume>68</volume>:<fpage>145011</fpage>. doi: <pub-id pub-id-type="doi">10.1088/1361-6560/acdfaf</pub-id>, PMID: <pub-id pub-id-type="pmid">37336207</pub-id></mixed-citation></ref>
<ref id="ref77"><label>77.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Lee</surname> <given-names>H</given-names></name> <name><surname>Lee</surname> <given-names>T</given-names></name> <name><surname>Lee</surname> <given-names>W</given-names></name></person-group>. <article-title>Development of a position-sensitive 4&#x03C0; Compton camera based on a single segmented scintillator</article-title>. <source>IEEE Trans Nucl Sci</source>. (<year>2020</year>) <volume>67</volume>:<fpage>2511</fpage>&#x2013;<lpage>22</lpage>. doi: <pub-id pub-id-type="doi">10.1109/TNS.2020.3037896</pub-id></mixed-citation></ref>
<ref id="ref78"><label>78.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Turecek</surname> <given-names>D</given-names></name> <name><surname>Jakubek</surname> <given-names>J</given-names></name> <name><surname>Trojanova</surname> <given-names>E</given-names></name> <name><surname>Sefc</surname> <given-names>L</given-names></name></person-group>. <article-title>Single layer Compton camera based on Timepix3 technology</article-title>. <source>J Instrum</source>. (<year>2020</year>) <volume>15</volume>:<fpage>C01014</fpage>. doi: <pub-id pub-id-type="doi">10.1088/1748-0221/15/01/C01014</pub-id></mixed-citation></ref>
<ref id="ref79"><label>79.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Karssemakers</surname> <given-names>LHE</given-names></name> <name><surname>Besseling</surname> <given-names>LMP</given-names></name> <name><surname>Schoonmade</surname> <given-names>LJ</given-names></name> <name><surname>Su</surname> <given-names>N</given-names></name> <name><surname>Nolte</surname> <given-names>JW</given-names></name> <name><surname>Raijmakers</surname> <given-names>PG</given-names></name> <etal/></person-group>. <article-title>Diagnostic accuracy of bone SPECT and SPECT/CT imaging in the diagnosis of unilateral condylar hyperplasia: a systematic review and meta-analysis</article-title>. <source>J Craniomaxillofac Surg</source>. (<year>2024</year>) <volume>52</volume>:<fpage>447</fpage>&#x2013;<lpage>53</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.jcms.2024.01.013</pub-id>, PMID: <pub-id pub-id-type="pmid">38378369</pub-id></mixed-citation></ref>
<ref id="ref80"><label>80.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Sakai</surname> <given-names>M</given-names></name> <name><surname>Kubota</surname> <given-names>Y</given-names></name> <name><surname>Parajuli</surname> <given-names>RK</given-names></name> <name><surname>Kikuchi</surname> <given-names>M</given-names></name> <name><surname>Arakawa</surname> <given-names>K</given-names></name> <name><surname>Nakano</surname> <given-names>T</given-names></name></person-group>. <article-title>Compton imaging with 99mTc for human imaging</article-title>. <source>Sci Rep</source>. (<year>2019</year>) <volume>9</volume>:<fpage>12906</fpage>. doi: <pub-id pub-id-type="doi">10.1038/s41598-019-49130-z</pub-id>, PMID: <pub-id pub-id-type="pmid">31501461</pub-id></mixed-citation></ref>
<ref id="ref81"><label>81.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Peng</surname> <given-names>P</given-names></name> <name><surname>Judenhofer</surname> <given-names>MS</given-names></name> <name><surname>Cherry</surname> <given-names>SR</given-names></name></person-group>. <article-title>Compton PET: a layered structure PET detector with high performance</article-title>. <source>Phys Med Biol</source>. (<year>2019</year>) <volume>64</volume>:<fpage>10LT01</fpage>. doi: <pub-id pub-id-type="doi">10.1088/1361-6560/ab1ba0</pub-id>, PMID: <pub-id pub-id-type="pmid">31013481</pub-id></mixed-citation></ref>
<ref id="ref82"><label>82.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Kasper</surname> <given-names>J</given-names></name> <name><surname>Rusiecka</surname> <given-names>K</given-names></name> <name><surname>Hetzel</surname> <given-names>R</given-names></name> <name><surname>Kozani</surname> <given-names>MK</given-names></name> <name><surname>Lalik</surname> <given-names>R</given-names></name> <name><surname>Magiera</surname> <given-names>A</given-names></name> <etal/></person-group>. <article-title>The SiFi-CC project &#x2013; feasibility study of a scintillation-fiber-based Compton camera for proton therapy monitoring</article-title>. <source>Phys Med</source>. (<year>2020</year>) <volume>76</volume>:<fpage>317</fpage>&#x2013;<lpage>25</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.ejmp.2020.07.013</pub-id>, PMID: <pub-id pub-id-type="pmid">32739785</pub-id></mixed-citation></ref>
<ref id="ref83"><label>83.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Roser</surname> <given-names>J</given-names></name> <name><surname>Barrientos</surname> <given-names>L</given-names></name> <name><surname>Bello</surname> <given-names>P</given-names></name> <name><surname>Borja-Lloret</surname> <given-names>M</given-names></name> <name><surname>Calatayud</surname> <given-names>JM</given-names></name> <name><surname>Casa&#x00F1;a</surname> <given-names>JV</given-names></name> <etal/></person-group>. <article-title>Radiopharmaceutical imaging of phantoms and patients with MACACO III Compton camera</article-title>. <source>Phys Med</source>. (<year>2025</year>) <volume>132</volume>:<fpage>104928</fpage>. doi: <pub-id pub-id-type="doi">10.1016/j.ejmp.2025.104928</pub-id>, PMID: <pub-id pub-id-type="pmid">40068545</pub-id></mixed-citation></ref>
<ref id="ref84"><label>84.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Yamamoto</surname> <given-names>S</given-names></name> <name><surname>Yamashita</surname> <given-names>T</given-names></name> <name><surname>Kobashi</surname> <given-names>Y</given-names></name> <name><surname>Yabe</surname> <given-names>T</given-names></name> <name><surname>Nakanishi</surname> <given-names>K</given-names></name> <name><surname>Akagi</surname> <given-names>T</given-names></name> <etal/></person-group>. <article-title>Development of a GAGG gamma camera for the imaging of prompt gammas during proton beam irradiation</article-title>. <source>Phys Med</source>. (<year>2024</year>) <volume>127</volume>:<fpage>104847</fpage>. doi: <pub-id pub-id-type="doi">10.1016/j.ejmp.2024.104847</pub-id>, PMID: <pub-id pub-id-type="pmid">39467468</pub-id></mixed-citation></ref>
<ref id="ref85"><label>85.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Keidar</surname> <given-names>Z</given-names></name> <name><surname>Israel</surname> <given-names>O</given-names></name> <name><surname>Krausz</surname> <given-names>Y</given-names></name></person-group>. <article-title>SPECT/CT in tumor imaging: technical aspects and clinical applications</article-title>. <source>Semin Nucl Med</source>. (<year>2003</year>) <volume>33</volume>:<fpage>205</fpage>&#x2013;<lpage>18</lpage>. doi: <pub-id pub-id-type="doi">10.1053/snuc.2003.127310</pub-id>, PMID: <pub-id pub-id-type="pmid">12931322</pub-id></mixed-citation></ref>
<ref id="ref86"><label>86.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Buck</surname> <given-names>AK</given-names></name> <name><surname>Nekolla</surname> <given-names>S</given-names></name> <name><surname>Ziegler</surname> <given-names>S</given-names></name> <name><surname>Beer</surname> <given-names>A</given-names></name> <name><surname>Krause</surname> <given-names>BJ</given-names></name> <name><surname>Herrmann</surname> <given-names>K</given-names></name> <etal/></person-group>. <article-title>SPECT/CT</article-title>. <source>J Nucl Med</source>. (<year>2008</year>) <volume>49</volume>:<fpage>1305</fpage>&#x2013;<lpage>19</lpage>. doi: <pub-id pub-id-type="doi">10.2967/jnumed.107.050195</pub-id>, PMID: <pub-id pub-id-type="pmid">18632825</pub-id></mixed-citation></ref>
<ref id="ref87"><label>87.</label><mixed-citation publication-type="book"><person-group person-group-type="author"><name><surname>Hasegawa</surname> <given-names>BH</given-names></name> <name><surname>Tang</surname> <given-names>HR</given-names></name> <name><surname>Da Silva</surname> <given-names>AJ</given-names></name> <name><surname>Iwata</surname> <given-names>K</given-names></name> <name><surname>Wu</surname> <given-names>MC</given-names></name> <name><surname>Wong</surname> <given-names>KH</given-names></name> <etal/></person-group>. <article-title>Implementation and applications of a combined CT/SPECT system</article-title> In: <source>1999 IEEE nuclear science symposium &#x2013; conference record, vols. 1&#x2013;3</source>. <publisher-loc>New York</publisher-loc>: <publisher-name>IEEE</publisher-name> (<year>1999</year>). <fpage>1373</fpage>&#x2013;<lpage>7</lpage>.</mixed-citation></ref>
<ref id="ref88"><label>88.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Pietrzyk</surname> <given-names>U</given-names></name> <name><surname>Herholz</surname> <given-names>K</given-names></name> <name><surname>Schuster</surname> <given-names>A</given-names></name> <name><surname>Stockhausen</surname> <given-names>HM</given-names></name> <name><surname>Lucht</surname> <given-names>H</given-names></name> <name><surname>Heiss</surname> <given-names>WD</given-names></name></person-group>. <article-title>Clinical applications of registration and fusion of multimodality brain images from PET, SPECT, CT, and MRI</article-title>. <source>Eur J Radiol</source>. (<year>1996</year>) <volume>21</volume>:<fpage>174</fpage>&#x2013;<lpage>82</lpage>. doi: <pub-id pub-id-type="doi">10.1016/0720-048X(95)00713-Z</pub-id>, PMID: <pub-id pub-id-type="pmid">8777907</pub-id></mixed-citation></ref>
<ref id="ref89"><label>89.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Aide</surname> <given-names>N</given-names></name> <name><surname>Lasnon</surname> <given-names>C</given-names></name> <name><surname>Desmonts</surname> <given-names>C</given-names></name> <name><surname>Armstrong</surname> <given-names>IS</given-names></name> <name><surname>Walker</surname> <given-names>MD</given-names></name> <name><surname>McGowan</surname> <given-names>DR</given-names></name></person-group>. <article-title>Advances in PET/CT technology: an update</article-title>. <source>Semin Nucl Med</source>. (<year>2022</year>) <volume>52</volume>:<fpage>286</fpage>&#x2013;<lpage>301</lpage>. doi: <pub-id pub-id-type="doi">10.1053/j.semnuclmed.2021.10.005</pub-id>, PMID: <pub-id pub-id-type="pmid">34823841</pub-id></mixed-citation></ref>
<ref id="ref90"><label>90.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Collarino</surname> <given-names>A</given-names></name> <name><surname>Fuoco</surname> <given-names>V</given-names></name> <name><surname>Garganese</surname> <given-names>G</given-names></name> <name><surname>Pereira Arias-Bouda</surname> <given-names>LM</given-names></name> <name><surname>Perotti</surname> <given-names>G</given-names></name> <name><surname>Manca</surname> <given-names>G</given-names></name> <etal/></person-group>. <article-title>Lymphoscintigraphy and sentinel lymph node biopsy in vulvar carcinoma: update from a European expert panel</article-title>. <source>Eur J Nucl Med Mol Imaging</source>. (<year>2020</year>) <volume>47</volume>:<fpage>1261</fpage>&#x2013;<lpage>74</lpage>. doi: <pub-id pub-id-type="doi">10.1007/s00259-019-04650-8</pub-id>, PMID: <pub-id pub-id-type="pmid">31897584</pub-id></mixed-citation></ref>
<ref id="ref91"><label>91.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Borrelli</surname> <given-names>P</given-names></name> <name><surname>Donswijk</surname> <given-names>ML</given-names></name> <name><surname>Stokkel</surname> <given-names>MP</given-names></name> <name><surname>Teixeira</surname> <given-names>SC</given-names></name> <name><surname>van Tinteren</surname> <given-names>H</given-names></name> <name><surname>Rutgers</surname> <given-names>EJT</given-names></name> <etal/></person-group>. <article-title>Contribution of SPECT/CT for sentinel node localization in patients with ipsilateral breast cancer relapse</article-title>. <source>Eur J Nucl Med Mol Imaging</source>. (<year>2017</year>) <volume>44</volume>:<fpage>630</fpage>&#x2013;<lpage>7</lpage>. doi: <pub-id pub-id-type="doi">10.1007/s00259-016-3545-8</pub-id>, PMID: <pub-id pub-id-type="pmid">27787592</pub-id></mixed-citation></ref>
<ref id="ref92"><label>92.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ritt</surname> <given-names>P</given-names></name></person-group>. <article-title>Recent developments in SPECT/CT</article-title>. <source>Semin Nucl Med</source>. (<year>2022</year>) <volume>52</volume>:<fpage>276</fpage>&#x2013;<lpage>85</lpage>. doi: <pub-id pub-id-type="doi">10.1053/j.semnuclmed.2022.01.004</pub-id>, PMID: <pub-id pub-id-type="pmid">35210065</pub-id></mixed-citation></ref>
<ref id="ref93"><label>93.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>de Zwart</surname> <given-names>AD</given-names></name> <name><surname>Beeres</surname> <given-names>FJP</given-names></name> <name><surname>Rietbergen</surname> <given-names>DDD</given-names></name> <name><surname>Krijnen</surname> <given-names>P</given-names></name> <name><surname>Schipper</surname> <given-names>IB</given-names></name></person-group>. <article-title>Initial experience of SPECT/CT in the diagnosis of occult scaphoid fracture</article-title>. <source>Acta Radiol Open</source>. (<year>2015</year>) <volume>4</volume>:<fpage>205846011560272</fpage>. doi: <pub-id pub-id-type="doi">10.1177/2058460115602729</pub-id>, PMID: <pub-id pub-id-type="pmid">26500783</pub-id></mixed-citation></ref>
<ref id="ref94"><label>94.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Lasloom</surname> <given-names>MD</given-names></name> <name><surname>Abuzaid</surname> <given-names>M</given-names></name></person-group>. <article-title>Enhanced diagnostic accuracy of pulmonary embolism: integrating low-dose CT with V/Q SPECT</article-title>. <source>Tomography</source>. (<year>2024</year>) <volume>10</volume>:<fpage>1294</fpage>&#x2013;<lpage>302</lpage>. doi: <pub-id pub-id-type="doi">10.3390/tomography10080096</pub-id>, PMID: <pub-id pub-id-type="pmid">39195731</pub-id></mixed-citation></ref>
<ref id="ref95"><label>95.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Currie</surname> <given-names>GM</given-names></name> <name><surname>Bailey</surname> <given-names>DL</given-names></name></person-group>. <article-title>V/Q SPECT and SPECT/CT in pulmonary embolism</article-title>. <source>J Nucl Med Technol</source>. (<year>2023</year>) <volume>51</volume>:<fpage>9</fpage>&#x2013;<lpage>15</lpage>. doi: <pub-id pub-id-type="doi">10.2967/jnmt.122.264880</pub-id>, PMID: <pub-id pub-id-type="pmid">36599703</pub-id></mixed-citation></ref>
<ref id="ref96"><label>96.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Agarwal</surname> <given-names>A</given-names></name> <name><surname>Traylor</surname> <given-names>KS</given-names></name> <name><surname>Branstetter</surname> <given-names>BF</given-names></name> <name><surname>Weyer</surname> <given-names>A</given-names></name> <name><surname>McCoy</surname> <given-names>KL</given-names></name> <name><surname>Muthukrishnan</surname> <given-names>A</given-names></name></person-group>. <article-title>4D SPECT/CT: a hybrid approach to primary hyperparathyroidism</article-title>. <source>J Nucl Med Technol</source>. (<year>2024</year>) <volume>52</volume>:<fpage>86</fpage>&#x2013;<lpage>90</lpage>. doi: <pub-id pub-id-type="doi">10.2967/jnmt.123.266990</pub-id>, PMID: <pub-id pub-id-type="pmid">38839121</pub-id></mixed-citation></ref>
<ref id="ref97"><label>97.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Willowson</surname> <given-names>KP</given-names></name> <name><surname>Bailey</surname> <given-names>DL</given-names></name></person-group>. <article-title>Evolving SPECT-CT technology</article-title>. <source>Br J Radiol</source>. (<year>2024</year>) <fpage>1</fpage>&#x2013;<lpage>9</lpage>. doi: <pub-id pub-id-type="doi">10.1093/bjr/tqae200</pub-id>, PMID: <pub-id pub-id-type="pmid">39383194</pub-id></mixed-citation></ref>
<ref id="ref98"><label>98.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Shirai</surname> <given-names>K</given-names></name> <name><surname>Nishiyama</surname> <given-names>K</given-names></name> <name><surname>Katsuda</surname> <given-names>T</given-names></name> <name><surname>Teshima</surname> <given-names>T</given-names></name> <name><surname>Ueda</surname> <given-names>Y</given-names></name> <name><surname>Miyazaki</surname> <given-names>M</given-names></name> <etal/></person-group>. <article-title>Phantom and clinical study of differences in cone beam computed tomographic registration when aligned to maximum and average intensity projection</article-title>. <source>Int J Radiat Oncol Biol Phys</source>. (<year>2014</year>) <volume>88</volume>:<fpage>189</fpage>&#x2013;<lpage>94</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.ijrobp.2013.09.031</pub-id>, PMID: <pub-id pub-id-type="pmid">24331666</pub-id></mixed-citation></ref>
<ref id="ref99"><label>99.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Danad</surname> <given-names>I</given-names></name> <name><surname>Raijmakers</surname> <given-names>PG</given-names></name> <name><surname>Appelman</surname> <given-names>YE</given-names></name> <name><surname>Harms</surname> <given-names>HJ</given-names></name> <name><surname>de Haan</surname> <given-names>S</given-names></name> <name><surname>van den Oever</surname> <given-names>MLP</given-names></name> <etal/></person-group>. <article-title>Hybrid imaging using quantitative H215O PET and CT-based coronary angiography for the detection of coronary artery disease</article-title>. <source>J Nucl Med</source>. (<year>2013</year>) <volume>54</volume>:<fpage>55</fpage>&#x2013;<lpage>63</lpage>. doi: <pub-id pub-id-type="doi">10.2967/jnumed.112.104687</pub-id>, PMID: <pub-id pub-id-type="pmid">23232274</pub-id></mixed-citation></ref>
<ref id="ref100"><label>100.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Browning</surname> <given-names>ZS</given-names></name> <name><surname>Wilkes</surname> <given-names>AA</given-names></name> <name><surname>Mackenzie</surname> <given-names>DS</given-names></name> <name><surname>Patterson</surname> <given-names>RM</given-names></name> <name><surname>Lenox</surname> <given-names>MW</given-names></name> <etal/></person-group>. <article-title>Using PET/CT imaging to characterize 18F-fluorodeoxyglucose utilization in fish</article-title>. <source>J Fish Dis</source>. (<year>2013</year>) <volume>36</volume>:<fpage>911</fpage>&#x2013;<lpage>9</lpage>. doi: <pub-id pub-id-type="doi">10.1111/jfd.12081</pub-id>, PMID: <pub-id pub-id-type="pmid">23488673</pub-id></mixed-citation></ref>
<ref id="ref101"><label>101.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Gnesin</surname> <given-names>S</given-names></name> <name><surname>Kieffer</surname> <given-names>C</given-names></name> <name><surname>Zeimpekis</surname> <given-names>K</given-names></name> <name><surname>Papazyan</surname> <given-names>JP</given-names></name> <name><surname>Guignard</surname> <given-names>R</given-names></name> <name><surname>Prior</surname> <given-names>JO</given-names></name> <etal/></person-group>. <article-title>Phantom-based image quality assessment of clinical 18F-FDG protocols in digital PET/CT and comparison to conventional PMT-based PET/CT</article-title>. <source>EJNMMI Phys</source>. (<year>2020</year>) <volume>7</volume>:<fpage>1</fpage>&#x2013;<lpage>16</lpage>. doi: <pub-id pub-id-type="doi">10.1186/s40658-019-0269-4</pub-id>, PMID: <pub-id pub-id-type="pmid">31907664</pub-id></mixed-citation></ref>
<ref id="ref102"><label>102.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Badawi</surname> <given-names>RD</given-names></name> <name><surname>Shi</surname> <given-names>H</given-names></name> <name><surname>Hu</surname> <given-names>P</given-names></name> <name><surname>Chen</surname> <given-names>S</given-names></name> <name><surname>Xu</surname> <given-names>T</given-names></name> <name><surname>Price</surname> <given-names>PM</given-names></name> <etal/></person-group>. <article-title>First human imaging studies with the EXPLORER total-body PET scanner</article-title>. <source>J Nucl Med</source>. (<year>2019</year>) <volume>60</volume>:<fpage>299</fpage>&#x2013;<lpage>303</lpage>. doi: <pub-id pub-id-type="doi">10.2967/jnumed.119.226498</pub-id>, PMID: <pub-id pub-id-type="pmid">30733314</pub-id></mixed-citation></ref>
<ref id="ref103"><label>103.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Alberts</surname> <given-names>I</given-names></name> <name><surname>H&#x00FC;nermund</surname> <given-names>JN</given-names></name> <name><surname>Prenosil</surname> <given-names>G</given-names></name> <name><surname>Mingels</surname> <given-names>C</given-names></name> <name><surname>Bohn</surname> <given-names>KP</given-names></name> <name><surname>Viscione</surname> <given-names>M</given-names></name> <etal/></person-group>. <article-title>Clinical performance of long axial field of view PET/CT: a head-to-head intra-individual comparison of the biograph vision Quadra with the biograph vision PET/CT</article-title>. <source>Eur J Nucl Med Mol Imaging</source>. (<year>2021</year>) <volume>48</volume>:<fpage>2395</fpage>&#x2013;<lpage>404</lpage>. doi: <pub-id pub-id-type="doi">10.1007/s00259-021-05282-7</pub-id>, PMID: <pub-id pub-id-type="pmid">33797596</pub-id></mixed-citation></ref>
<ref id="ref104"><label>104.</label><mixed-citation publication-type="other"><person-group person-group-type="author"><name><surname>Siegel</surname> <given-names>S</given-names></name> <name><surname>Aykac</surname> <given-names>M</given-names></name> <name><surname>Bal</surname> <given-names>H</given-names></name> <name><surname>Bendriem</surname> <given-names>B</given-names></name> <name><surname>Bharkhada</surname> <given-names>D</given-names></name> <name><surname>Cabello</surname> <given-names>J</given-names></name> <etal/></person-group>. <article-title>Preliminary performance of a prototype, one-meter long PET tomograph</article-title>. <source>In: 2020 IEEE nuclear science symposium and medical imaging conference (NSS/MIC); 2020 Oct 31-Nov 7; virtual conference</source>. <publisher-loc>Piscataway, NJ</publisher-loc>: <publisher-name>IEEE</publisher-name>; (<year>2020</year>).p.31.</mixed-citation></ref>
<ref id="ref105"><label>105.</label><mixed-citation publication-type="other"><person-group person-group-type="author"><collab id="coll1">Siemens Healthineers</collab></person-group>. Biograph vision. (<year>2021</year>). Available online at: <ext-link xlink:href="https://www.siemens-healthineers.com/molecular-imaging/pet-ct/biograph-vision" ext-link-type="uri">https://www.siemens-healthineers.com/molecular-imaging/pet-ct/biograph-vision</ext-link> (Accessed October 2, 2021).</mixed-citation></ref>
<ref id="ref106"><label>106.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Njiti</surname> <given-names>MM</given-names></name> <name><surname>Osman</surname> <given-names>ND</given-names></name> <name><surname>Mansor</surname> <given-names>MS</given-names></name> <name><surname>Rabaiee</surname> <given-names>NA</given-names></name> <name><surname>Abdul Aziz</surname> <given-names>MZ</given-names></name></person-group>. <article-title>Potential of metal artifact reduction (MAR) and deep learning-based reconstruction (DLR) algorithms integration in CT metal artifact correction: a review</article-title>. <source>Radiat Phys Chem</source>. (<year>2024</year>) <volume>218</volume>:<fpage>111541</fpage>. doi: <pub-id pub-id-type="doi">10.1016/j.radphyschem.2024.111541</pub-id></mixed-citation></ref>
<ref id="ref107"><label>107.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Lee</surname> <given-names>WW</given-names></name> <name><surname>Marinelli</surname> <given-names>B</given-names></name> <name><surname>Van Der Laan</surname> <given-names>AM</given-names></name> <name><surname>Sena</surname> <given-names>BF</given-names></name> <name><surname>Gorbatov</surname> <given-names>R</given-names></name> <name><surname>Leuschner</surname> <given-names>F</given-names></name> <etal/></person-group>. <article-title>PET/MRI of inflammation in myocardial infarction</article-title>. <source>J Am Coll Cardiol</source>. (<year>2012</year>) <volume>59</volume>:<fpage>153</fpage>&#x2013;<lpage>63</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.jacc.2011.08.066</pub-id>, PMID: <pub-id pub-id-type="pmid">22222080</pub-id></mixed-citation></ref>
<ref id="ref108"><label>108.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Kj&#x00E6;r</surname> <given-names>A</given-names></name> <name><surname>Loft</surname> <given-names>A</given-names></name> <name><surname>Law</surname> <given-names>I</given-names></name> <name><surname>Berthelsen</surname> <given-names>AK</given-names></name> <name><surname>Borgwardt</surname> <given-names>L</given-names></name> <name><surname>L&#x00F6;fgren</surname> <given-names>J</given-names></name> <etal/></person-group>. <article-title>PET/MRI in cancer patients: first experiences and vision from Copenhagen</article-title>. <source>Magn Reson Mater Phy</source>. (<year>2013</year>) <volume>26</volume>:<fpage>37</fpage>&#x2013;<lpage>47</lpage>. doi: <pub-id pub-id-type="doi">10.1007/s10334-012-0357-0</pub-id>, PMID: <pub-id pub-id-type="pmid">23266511</pub-id></mixed-citation></ref>
<ref id="ref109"><label>109.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Hirsch</surname> <given-names>FW</given-names></name> <name><surname>Sattler</surname> <given-names>B</given-names></name> <name><surname>Sorge</surname> <given-names>I</given-names></name> <name><surname>Kurch</surname> <given-names>L</given-names></name> <name><surname>Viehweger</surname> <given-names>A</given-names></name> <name><surname>Ritter</surname> <given-names>L</given-names></name> <etal/></person-group>. <article-title>PET/MR in children. Initial clinical experience in paediatric oncology using an integrated PET/MR scanner</article-title>. <source>Pediatr Radiol</source>. (<year>2013</year>) <volume>43</volume>:<fpage>860</fpage>&#x2013;<lpage>75</lpage>. doi: <pub-id pub-id-type="doi">10.1007/s00247-012-2570-4</pub-id>, PMID: <pub-id pub-id-type="pmid">23306377</pub-id></mixed-citation></ref>
<ref id="ref110"><label>110.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Quick</surname> <given-names>HH</given-names></name> <name><surname>Ladebeck</surname> <given-names>R</given-names></name> <name><surname>Georgi</surname> <given-names>J</given-names></name></person-group>. <article-title>Whole-body MR/PET hybrid imaging: technical considerations, clinical workflow, and initial results</article-title>. <source>MAGNETOM Flash</source>. (<year>2011</year>) <volume>1</volume>:<fpage>88</fpage>&#x2013;<lpage>100</lpage>.</mixed-citation></ref>
<ref id="ref111"><label>111.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Levin</surname> <given-names>C</given-names></name> <name><surname>Glover</surname> <given-names>G</given-names></name> <name><surname>Deller</surname> <given-names>T</given-names></name> <name><surname>McDaniel</surname> <given-names>D</given-names></name> <name><surname>Peterson</surname> <given-names>W</given-names></name> <name><surname>Maramraju</surname> <given-names>SH</given-names></name> <etal/></person-group>. <article-title>Prototype time-of-flight PET ring integrated with a 3T MRI system for simultaneous whole-body PET/MR imaging</article-title>. <source>J Nucl Med</source>. (<year>2013</year>) <volume>54</volume>:<fpage>148</fpage>&#x2013;<lpage>8</lpage>.</mixed-citation></ref>
<ref id="ref112"><label>112.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Mirshahvalad</surname> <given-names>SA</given-names></name> <name><surname>Farag</surname> <given-names>A</given-names></name> <name><surname>Thiessen</surname> <given-names>J</given-names></name> <name><surname>Wong</surname> <given-names>R</given-names></name> <name><surname>Veit-Haibach</surname> <given-names>P</given-names></name></person-group>. <article-title>Current applications of PET/MR: part I: technical basics and preclinical/clinical applications</article-title>. <source>Can Assoc Radiol J</source>. (<year>2024</year>) <volume>75</volume>:<fpage>815</fpage>&#x2013;<lpage>25</lpage>. doi: <pub-id pub-id-type="doi">10.1177/08465371241255903</pub-id>, PMID: <pub-id pub-id-type="pmid">38813998</pub-id></mixed-citation></ref>
<ref id="ref113"><label>113.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Hamamura</surname> <given-names>MJ</given-names></name> <name><surname>Ha</surname> <given-names>S</given-names></name> <name><surname>Roeck</surname> <given-names>WW</given-names></name> <name><surname>Muftuler</surname> <given-names>LT</given-names></name> <name><surname>Wagenaar</surname> <given-names>DJ</given-names></name> <name><surname>Meier</surname> <given-names>D</given-names></name> <etal/></person-group>. <article-title>Development of an MR-compatible SPECT system (MRSPECT) for simultaneous data acquisition</article-title>. <source>Phys Med Biol</source>. (<year>2010</year>) <volume>55</volume>:<fpage>1563</fpage>&#x2013;<lpage>75</lpage>. doi: <pub-id pub-id-type="doi">10.1088/0031-9155/55/6/002</pub-id>, PMID: <pub-id pub-id-type="pmid">20164533</pub-id></mixed-citation></ref>
<ref id="ref114"><label>114.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Hutton</surname> <given-names>BF</given-names></name> <name><surname>Occhipinti</surname> <given-names>M</given-names></name> <name><surname>Kuehne</surname> <given-names>A</given-names></name> <name><surname>M&#x00E1;th&#x00E9;</surname> <given-names>D</given-names></name> <name><surname>Kov&#x00E1;cs</surname> <given-names>N</given-names></name> <name><surname>Waiczies</surname> <given-names>H</given-names></name> <etal/></person-group>. <article-title>Development of clinical simultaneous SPECT/MRI</article-title>. <source>Br J Radiol</source>. (<year>2018</year>) <volume>91</volume>:<fpage>20160690</fpage>. doi: <pub-id pub-id-type="doi">10.1259/bjr.20160690</pub-id>, PMID: <pub-id pub-id-type="pmid">28008775</pub-id></mixed-citation></ref>
<ref id="ref115"><label>115.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Carminati</surname> <given-names>M</given-names></name> <name><surname>D&#x2019;Adda</surname> <given-names>I</given-names></name> <name><surname>Morahan</surname> <given-names>AJ</given-names></name> <name><surname>Erlandsson</surname> <given-names>K</given-names></name> <name><surname>Nagy</surname> <given-names>K</given-names></name> <name><surname>Czeller</surname> <given-names>M</given-names></name> <etal/></person-group>. <article-title>Clinical SiPM-based MRI-compatible SPECT: preliminary characterization</article-title>. <source>IEEE trans Radiat Plasma Med Sci</source>. (<year>2019</year>) <volume>4</volume>:<fpage>371</fpage>&#x2013;<lpage>7</lpage>. doi: <pub-id pub-id-type="doi">10.1109/TRPMS.2019.2951355</pub-id>, PMID: <pub-id pub-id-type="pmid">41116384</pub-id></mixed-citation></ref>
<ref id="ref116"><label>116.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Cai</surname> <given-names>L</given-names></name> <name><surname>Lai</surname> <given-names>X</given-names></name> <name><surname>Shen</surname> <given-names>Z</given-names></name> <name><surname>Chen</surname> <given-names>CT</given-names></name> <name><surname>Meng</surname> <given-names>LJ</given-names></name> <etal/></person-group>. <article-title>MRC-SPECT: a sub-500 &#x03BC;m resolution MR-compatible SPECT system for simultaneous dual-modality study of small animals</article-title>. <source>Nucl Instrum Methods Phys Res B</source>. (<year>2014</year>) <volume>734</volume>:<fpage>147</fpage>&#x2013;<lpage>51</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.nima.2013.08.080</pub-id>, PMID: <pub-id pub-id-type="pmid">26722136</pub-id></mixed-citation></ref>
<ref id="ref117"><label>117.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Rauscher</surname> <given-names>I</given-names></name> <name><surname>Eiber</surname> <given-names>M</given-names></name> <name><surname>Souvatzoglou</surname> <given-names>M</given-names></name> <name><surname>Schwaiger</surname> <given-names>M</given-names></name> <name><surname>Beer</surname> <given-names>AJ</given-names></name></person-group>. <article-title>PET/MR in oncology: non&#x2013;18F-FDG tracers for routine applications</article-title>. <source>J Nucl Med</source>. (<year>2014</year>) <volume>55</volume>:<fpage>25S</fpage>&#x2013;<lpage>31S</lpage>. doi: <pub-id pub-id-type="doi">10.2967/jnumed.113.129536</pub-id>, PMID: <pub-id pub-id-type="pmid">24819421</pub-id></mixed-citation></ref>
<ref id="ref118"><label>118.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Verger</surname> <given-names>A</given-names></name> <name><surname>Grimaldi</surname> <given-names>S</given-names></name> <name><surname>Ribeiro</surname> <given-names>M-J</given-names></name> <name><surname>Frismand</surname> <given-names>S</given-names></name> <name><surname>Guedj</surname> <given-names>E</given-names></name> <etal/></person-group>. <article-title>Single photon emission computed tomography/positron emission tomography molecular imaging for parkinsonism: a fast-developing field</article-title>. <source>Ann Neurol</source>. (<year>2021</year>) <volume>90</volume>:<fpage>711</fpage>&#x2013;<lpage>9</lpage>. doi: <pub-id pub-id-type="doi">10.1002/ana.26187</pub-id>, PMID: <pub-id pub-id-type="pmid">34338333</pub-id></mixed-citation></ref>
<ref id="ref119"><label>119.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>van der Meulen</surname> <given-names>N</given-names></name> <name><surname>Strobel</surname> <given-names>K</given-names></name> <name><surname>Lima</surname> <given-names>T</given-names></name></person-group>. <article-title>New radionuclides and technological advances in SPECT and PET scanners</article-title>. <source>Cancer</source>. (<year>2021</year>) <volume>13</volume>:<fpage>6183</fpage>. doi: <pub-id pub-id-type="doi">10.3390/cancers13246183</pub-id>, PMID: <pub-id pub-id-type="pmid">34944803</pub-id></mixed-citation></ref>
<ref id="ref120"><label>120.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ogane</surname> <given-names>K</given-names></name> <name><surname>Uenomachi</surname> <given-names>M</given-names></name> <name><surname>Shimazoe</surname> <given-names>K</given-names></name> <name><surname>Kamada</surname> <given-names>K</given-names></name> <name><surname>Takahashi</surname> <given-names>M</given-names></name> <name><surname>Momose</surname> <given-names>T</given-names></name> <etal/></person-group>. <article-title>Development of Compton-PET hybrid imaging of diagnostic and therapeutic nuclides for theranostics</article-title>. <source>J Nucl Med</source>. (<year>2020</year>) <volume>61</volume>:<fpage>1515</fpage>.</mixed-citation></ref>
<ref id="ref121"><label>121.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Kim</surname> <given-names>D</given-names></name> <name><surname>Shimazoe</surname> <given-names>K</given-names></name> <name><surname>Uenomachi</surname> <given-names>M</given-names></name> <name><surname>Takahashi</surname> <given-names>H</given-names></name></person-group>. <article-title>Dynamic imaging comparison of 18F-FDG tracers with Compton imaging and PET coincidence imaging</article-title>. <source>J Instrum</source>. (<year>2022</year>) <volume>17</volume>:<fpage>C07018</fpage>. doi: <pub-id pub-id-type="doi">10.1088/1748-0221/17/07/C07018</pub-id></mixed-citation></ref>
<ref id="ref122"><label>122.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Yoshida</surname> <given-names>E</given-names></name> <name><surname>Tashima</surname> <given-names>H</given-names></name> <name><surname>Nagatsu</surname> <given-names>K</given-names></name> <name><surname>Tsuji</surname> <given-names>AB</given-names></name> <name><surname>Kamada</surname> <given-names>K</given-names></name> <name><surname>Parodi</surname> <given-names>K</given-names></name> <etal/></person-group>. <article-title>Whole gamma imaging: a new concept of PET combined with Compton imaging</article-title>. <source>Phys Med Biol</source>. (<year>2020</year>) <volume>65</volume>:<fpage>125013</fpage>. doi: <pub-id pub-id-type="doi">10.1088/1361-6560/ab8e89</pub-id>, PMID: <pub-id pub-id-type="pmid">32348968</pub-id></mixed-citation></ref>
<ref id="ref123"><label>123.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Omata</surname> <given-names>A</given-names></name> <name><surname>Masubuchi</surname> <given-names>M</given-names></name> <name><surname>Koshikawa</surname> <given-names>N</given-names></name> <name><surname>Kataoka</surname> <given-names>J</given-names></name> <name><surname>Kato</surname> <given-names>H</given-names></name> <name><surname>Toyoshima</surname> <given-names>A</given-names></name> <etal/></person-group>. <article-title>Multi-modal 3D imaging of radionuclides using multiple hybrid Compton cameras</article-title>. <source>Sci Rep</source>. (<year>2022</year>) <volume>12</volume>:<fpage>2546</fpage>. doi: <pub-id pub-id-type="doi">10.1038/s41598-022-06401-6</pub-id>, PMID: <pub-id pub-id-type="pmid">35169183</pub-id></mixed-citation></ref>
<ref id="ref124"><label>124.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Wei</surname> <given-names>Q</given-names></name> <name><surname>Wang</surname> <given-names>S</given-names></name> <name><surname>Ma</surname> <given-names>T</given-names></name> <name><surname>Wu</surname> <given-names>J</given-names></name> <name><surname>Liu</surname> <given-names>H</given-names></name> <name><surname>Xu</surname> <given-names>T</given-names></name> <etal/></person-group>. <article-title>Performance evaluation of a compact PET/SPECT/CT tri-modality system for small animal imaging applications</article-title>. <source>Nucl Instrum Methods Phys Res, Sect A</source>. (<year>2015</year>) <volume>786</volume>:<fpage>147</fpage>&#x2013;<lpage>54</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.nima.2015.03.045</pub-id></mixed-citation></ref>
<ref id="ref125"><label>125.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Zhou</surname> <given-names>K</given-names></name> <name><surname>Meng</surname> <given-names>X</given-names></name> <name><surname>Xie</surname> <given-names>Z</given-names></name> <name><surname>Li</surname> <given-names>SY</given-names></name> <name><surname>Tian</surname> <given-names>J</given-names></name> <name><surname>Yang</surname> <given-names>K</given-names></name> <etal/></person-group>. <article-title>A novel quad-modality molecular imaging system for small animals1</article-title>. <source>China Medical Devices</source>. (<year>2015</year>) <volume>2</volume>:<fpage>7</fpage>&#x2013;<lpage>10</lpage>. doi: <pub-id pub-id-type="doi">10.3969/j.issn.1674-1633.2015.02.002</pub-id></mixed-citation></ref>
<ref id="ref126"><label>126.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Hutton</surname> <given-names>BF</given-names></name></person-group>. <article-title>The origins of SPECT and SPECT/CT</article-title>. <source>Eur J Nucl Med Mol Imaging</source>. (<year>2014</year>) <volume>41</volume>:<fpage>3</fpage>&#x2013;<lpage>16</lpage>. doi: <pub-id pub-id-type="doi">10.1007/s00259-013-2606-5</pub-id>, PMID: <pub-id pub-id-type="pmid">24218098</pub-id></mixed-citation></ref>
<ref id="ref127"><label>127.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Wang</surname> <given-names>SD</given-names></name> <name><surname>Ma</surname> <given-names>TY</given-names></name> <name><surname>Yao</surname> <given-names>RT</given-names></name></person-group>. <article-title>Axial movement parameter study on preclinical slit-slat SPECT</article-title>. <source>IEEE Trans Nucl Sci</source>. (<year>2015</year>) <volume>63</volume>:<fpage>84</fpage>&#x2013;<lpage>9</lpage>. doi: <pub-id pub-id-type="doi">10.1109/TNS.2015.2493043</pub-id>, PMID: <pub-id pub-id-type="pmid">41116384</pub-id></mixed-citation></ref>
<ref id="ref128"><label>128.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ma</surname> <given-names>TY</given-names></name> <name><surname>Wei</surname> <given-names>QY</given-names></name> <name><surname>Lyu</surname> <given-names>Z</given-names></name> <name><surname>Zhang</surname> <given-names>D</given-names></name> <name><surname>Zhang</surname> <given-names>H</given-names></name> <name><surname>Wang</surname> <given-names>R</given-names></name> <etal/></person-group>. <article-title>Self-collimating SPECT with multi-layer interspaced mosaic detectors</article-title>. <source>IEEE Trans Med Imaging</source>. (<year>2021</year>) <volume>40</volume>:<fpage>2152</fpage>&#x2013;<lpage>69</lpage>. doi: <pub-id pub-id-type="doi">10.1109/TMI.2021.3073288</pub-id>, PMID: <pub-id pub-id-type="pmid">33852384</pub-id></mixed-citation></ref>
<ref id="ref129"><label>129.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Zhang</surname> <given-names>DB</given-names></name> <name><surname>Ma</surname> <given-names>TY</given-names></name> <name><surname>Lv</surname> <given-names>ZL</given-names></name> <name><surname>Wei</surname> <given-names>QY</given-names></name> <name><surname>Xu</surname> <given-names>TP</given-names></name> <name><surname>Zhang</surname> <given-names>HY</given-names></name> <etal/></person-group>. <article-title>Design and performance evaluation of a self-collimating SPECT system for small animal imaging</article-title>. <source>J Nucl Med</source>. (<year>2020</year>) <volume>61</volume>:<fpage>316</fpage>.</mixed-citation></ref>
<ref id="ref130"><label>130.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Wei</surname> <given-names>QY</given-names></name> <name><surname>Lyu</surname> <given-names>ZL</given-names></name> <name><surname>Jiang</surname> <given-names>NM</given-names></name> <name><surname>Deng</surname> <given-names>Z</given-names></name> <name><surname>Xu</surname> <given-names>T</given-names></name> <name><surname>Sun</surname> <given-names>L</given-names></name> <etal/></person-group>. <article-title>Study of 99mTc absorption on micro-sized ion exchange resins to achieve high activity for SPECT</article-title>. <source>Appl Radiat Isot</source>. (<year>2022</year>) <volume>186</volume>:<fpage>110256</fpage>. doi: <pub-id pub-id-type="doi">10.1016/j.apradiso.2022.110256</pub-id>, PMID: <pub-id pub-id-type="pmid">35533606</pub-id></mixed-citation></ref>
<ref id="ref131"><label>131.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Zhang</surname> <given-names>DB</given-names></name> <name><surname>Lyu</surname> <given-names>Z</given-names></name> <name><surname>Liu</surname> <given-names>YQ</given-names></name> <name><surname>He</surname> <given-names>ZX</given-names></name> <name><surname>Yao</surname> <given-names>R</given-names></name> <name><surname>Ma</surname> <given-names>T</given-names></name></person-group>. <article-title>Characterization and assessment of projection probability density function and enhanced sampling in self-collimation SPECT</article-title>. <source>IEEE Trans Med Imaging</source>. (<year>2023</year>) <volume>42</volume>:<fpage>2787</fpage>&#x2013;<lpage>801</lpage>. doi: <pub-id pub-id-type="doi">10.1109/TMI.2023.3265874</pub-id>, PMID: <pub-id pub-id-type="pmid">37037258</pub-id></mixed-citation></ref>
<ref id="ref132"><label>132.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Zhang</surname> <given-names>DB</given-names></name> <name><surname>Zheng</surname> <given-names>XC</given-names></name> <name><surname>Hu</surname> <given-names>YF</given-names></name> <name><surname>Lyu</surname> <given-names>ZL</given-names></name> <name><surname>He</surname> <given-names>ZX</given-names></name> <name><surname>Liu</surname> <given-names>YQ</given-names></name> <etal/></person-group>. <article-title>Feasibility study of a self-collimating SPECT for fast dynamic cardiac imaging</article-title>. <source>J Nucl Med</source>. (<year>2022</year>) <volume>63</volume>:<fpage>2338</fpage>.</mixed-citation></ref>
<ref id="ref133"><label>133.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Wei</surname> <given-names>QY</given-names></name> <name><surname>Ma</surname> <given-names>TY</given-names></name> <name><surname>Jiang</surname> <given-names>NM</given-names></name> <name><surname>Xu</surname> <given-names>T</given-names></name> <name><surname>Lyu</surname> <given-names>Z</given-names></name> <name><surname>Hu</surname> <given-names>Y</given-names></name> <etal/></person-group>. <article-title>A side-by-side LYSO/GAGG phoswich detector aiming for SPECT imaging</article-title>. <source>Nucl Instrum Methods Phys Res A.</source> (<year>2020</year>) <volume>953</volume>:<fpage>163242</fpage>. doi: <pub-id pub-id-type="doi">10.1016/j.nima.2019.163242</pub-id></mixed-citation></ref>
<ref id="ref134"><label>134.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Guo</surname> <given-names>L</given-names></name> <name><surname>Ma</surname> <given-names>TY</given-names></name> <name><surname>Zhang</surname> <given-names>DB</given-names></name> <name><surname>Hu</surname> <given-names>YF</given-names></name> <name><surname>Liu</surname> <given-names>YQ</given-names></name> <name><surname>Yao</surname> <given-names>RT</given-names></name></person-group>. <article-title>Design and simulations of a self-collimating whole-body SPECT system</article-title>. <source>J Nucl Med</source>. (<year>2021</year>) <volume>62</volume>:<fpage>1135</fpage>.</mixed-citation></ref>
<ref id="ref135"><label>135.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Guo</surname> <given-names>L</given-names></name> <name><surname>Zhang</surname> <given-names>DB</given-names></name> <name><surname>Yao</surname> <given-names>RT</given-names></name></person-group>. <article-title>Optimization and performance evaluation of a self-collimation single-photon emission breast tomography design</article-title>. <source>J Nucl Med</source>. (<year>2022</year>) <volume>63</volume>:<fpage>3311</fpage>.</mixed-citation></ref>
<ref id="ref136"><label>136.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Pahlka</surname> <given-names>R</given-names></name> <name><surname>Kappadath</surname> <given-names>S</given-names></name> <name><surname>Mawlawi</surname> <given-names>O</given-names></name></person-group>. <article-title>Su-g-iep4-12: performance of in-111 coincident gamma-ray counting: a Monte Carlo simulation</article-title>. <source>Med Phys</source>. (<year>2016</year>) <volume>43</volume>:<fpage>3680</fpage>. doi: <pub-id pub-id-type="doi">10.1118/1.4957107</pub-id></mixed-citation></ref>
<ref id="ref137"><label>137.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Shimazoe</surname> <given-names>K</given-names></name> <name><surname>Uenomachi</surname> <given-names>M</given-names></name> <name><surname>Takahashi</surname> <given-names>H</given-names></name></person-group>. <article-title>Imaging and sensing of pH and chemical state with nuclear-spin-correlated cascade gamma rays via radioactive tracer</article-title>. <source>Commun Phys</source>. (<year>2022</year>) <volume>5</volume>:<fpage>1</fpage>&#x2013;<lpage>8</lpage>. doi: <pub-id pub-id-type="doi">10.1038/s42005-022-00801-w</pub-id>, PMID: <pub-id pub-id-type="pmid">41203860</pub-id></mixed-citation></ref>
<ref id="ref138"><label>138.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Weineisen</surname> <given-names>M</given-names></name> <name><surname>Schottelius</surname> <given-names>M</given-names></name> <name><surname>Simecek</surname> <given-names>J</given-names></name> <name><surname>Baum</surname> <given-names>RP</given-names></name> <name><surname>Yildiz</surname> <given-names>A</given-names></name> <name><surname>Beykan</surname> <given-names>S</given-names></name> <etal/></person-group>. <article-title>68Ga- and 177Lu-labeled PSMA I&#x0026;T: optimization of a PSMA-targeted theranostic concept and first proof-of-concept human studies</article-title>. <source>J Nucl Med</source>. (<year>2015</year>) <volume>56</volume>:<fpage>1169</fpage>&#x2013;<lpage>76</lpage>. doi: <pub-id pub-id-type="doi">10.2967/jnumed.115.158550</pub-id>, PMID: <pub-id pub-id-type="pmid">26089548</pub-id></mixed-citation></ref>
<ref id="ref139"><label>139.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Kratochwil</surname> <given-names>C</given-names></name> <name><surname>Giesel</surname> <given-names>FL</given-names></name> <name><surname>Stefanova</surname> <given-names>M</given-names></name> <name><surname>Bene&#x0161;ov&#x00E1;</surname> <given-names>M</given-names></name> <name><surname>Bronzel</surname> <given-names>M</given-names></name> <name><surname>Afshar-Oromieh</surname> <given-names>A</given-names></name> <etal/></person-group>. <article-title>PSMA-targeted radionuclide therapy of metastatic castration-resistant prostate cancer with 177Lu-labeled PSMA-617</article-title>. <source>J Nucl Med</source>. (<year>2016</year>) <volume>57</volume>:<fpage>1170</fpage>&#x2013;<lpage>6</lpage>. doi: <pub-id pub-id-type="doi">10.2967/jnumed.115.171397</pub-id>, PMID: <pub-id pub-id-type="pmid">26985056</pub-id></mixed-citation></ref>
<ref id="ref140"><label>140.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Guo</surname> <given-names>H</given-names></name> <name><surname>Miao</surname> <given-names>Y</given-names></name></person-group>. <article-title>Melanoma targeting property of a Lu-177-labeled lactam brid/ge-cyclized alphaMSH peptide</article-title>. <source>Bioorg Med Chem Lett</source>. (<year>2013</year>) <volume>23</volume>:<fpage>2319</fpage>&#x2013;<lpage>23</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.bmcl.2013.02.069</pub-id>, PMID: <pub-id pub-id-type="pmid">23473679</pub-id></mixed-citation></ref>
<ref id="ref141"><label>141.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Uribe</surname> <given-names>CF</given-names></name> <name><surname>Esquinas</surname> <given-names>PL</given-names></name> <name><surname>Tanguay</surname> <given-names>J</given-names></name> <name><surname>Gonzalez</surname> <given-names>M</given-names></name> <name><surname>Gaudin</surname> <given-names>E</given-names></name> <name><surname>Beauregard</surname> <given-names>JM</given-names></name> <etal/></person-group>. <article-title>Accuracy of 177Lu activity quantification in SPECT imaging: a phantom study</article-title>. <source>EJNMMI Phys</source>. (<year>2017</year>) <volume>4</volume>:<fpage>2</fpage>. doi: <pub-id pub-id-type="doi">10.1186/s40658-016-0170-3</pub-id>, PMID: <pub-id pub-id-type="pmid">28063068</pub-id></mixed-citation></ref>
<ref id="ref142"><label>142.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ljungberg</surname> <given-names>M</given-names></name> <name><surname>Celler</surname> <given-names>A</given-names></name> <name><surname>Konijnenberg</surname> <given-names>MW</given-names></name> <name><surname>Eckerman</surname> <given-names>KF</given-names></name> <name><surname>Dewaraja</surname> <given-names>YK</given-names></name> <name><surname>Sj&#x00F6;green-Gleisner</surname> <given-names>K</given-names></name> <etal/></person-group>. <article-title>MIRD pamphlet no. 26: joint EANM/MIRD guidelines for quantitative 177Lu SPECT applied for dosimetry of radiopharmaceutical therapy</article-title>. <source>J Nucl Med</source>. (<year>2016</year>) <volume>57</volume>:<fpage>151</fpage>&#x2013;<lpage>62</lpage>. doi: <pub-id pub-id-type="doi">10.2967/jnumed.115.159012</pub-id>, PMID: <pub-id pub-id-type="pmid">26471692</pub-id></mixed-citation></ref>
<ref id="ref143"><label>143.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Lin</surname> <given-names>CS</given-names></name> <name><surname>Lin</surname> <given-names>HH</given-names></name> <name><surname>Ni</surname> <given-names>YC</given-names></name> <name><surname>Jan</surname> <given-names>ML</given-names></name> <name><surname>Lu</surname> <given-names>KP</given-names></name> <name><surname>Chuang</surname> <given-names>KS</given-names></name></person-group>. <article-title>Application of the intraoperative dual photon emission computed tomography system in sentinel lymph node detection: a simulation study</article-title>. <source>IEEE Trans Nucl Sci</source>. (<year>2016</year>) <volume>63</volume>:<fpage>108</fpage>&#x2013;<lpage>16</lpage>. doi: <pub-id pub-id-type="doi">10.1109/TNS.2015.2503479</pub-id></mixed-citation></ref>
<ref id="ref144"><label>144.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Pahlka</surname> <given-names>RB</given-names></name> <name><surname>Kappadath</surname> <given-names>SC</given-names></name> <name><surname>Mawlawi</surname> <given-names>OR</given-names></name></person-group>. <article-title>A Monte Carlo simulation of coincidence detection and imaging of gamma-ray cascades with a scintillation camera</article-title>. <source>Biomed Phys Eng Express</source>. (<year>2018</year>) <volume>4</volume>:<fpage>055012</fpage>. doi: <pub-id pub-id-type="doi">10.1088/2057-1976/aad572</pub-id></mixed-citation></ref>
<ref id="ref145"><label>145.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Shimazoe</surname> <given-names>K</given-names></name> <name><surname>Uenomachi</surname> <given-names>M</given-names></name> <name><surname>Mizumachi</surname> <given-names>Y</given-names></name> <name><surname>Takahashi</surname> <given-names>H</given-names></name> <name><surname>Masao</surname> <given-names>Y</given-names></name> <name><surname>Shoji</surname> <given-names>Y</given-names></name> <etal/></person-group>. <article-title>Double photon emission coincidence imaging using GAGG-SiPM pixel detectors</article-title>. <source>J Instrum</source>. (<year>2017</year>) <volume>12</volume>:<fpage>C12055</fpage>. doi: <pub-id pub-id-type="doi">10.1088/1748-0221/12/12/C12055</pub-id></mixed-citation></ref>
<ref id="ref146"><label>146.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Uenomachi</surname> <given-names>M</given-names></name> <name><surname>Mizumachi</surname> <given-names>Y</given-names></name> <name><surname>Yoshihara</surname> <given-names>Y</given-names></name> <name><surname>Takahashi</surname> <given-names>H</given-names></name> <name><surname>Shimazoe</surname> <given-names>K</given-names></name> <name><surname>Yabu</surname> <given-names>G</given-names></name> <etal/></person-group>. <article-title>Double photon emission coincidence imaging with GAGG-SiPM Compton camera</article-title>. <source>Nucl Instrum Methods Phys Res A.</source> (<year>2020</year>) <volume>954</volume>:<fpage>161682</fpage>. doi: <pub-id pub-id-type="doi">10.1016/j.nima.2018.11.141</pub-id></mixed-citation></ref>
<ref id="ref147"><label>147.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Yoshihara</surname> <given-names>Y</given-names></name> <name><surname>Shimazoe</surname> <given-names>K</given-names></name> <name><surname>Mizumachi</surname> <given-names>Y</given-names></name> <name><surname>Takahashi</surname> <given-names>H</given-names></name></person-group>. <article-title>Evaluation of double photon coincidence Compton imaging method with GEANT4 simulation</article-title>. <source>Nucl Instrum Methods Phys Res A.</source> (<year>2017</year>) <volume>873</volume>:<fpage>51</fpage>&#x2013;<lpage>5</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.nima.2017.05.039</pub-id></mixed-citation></ref>
<ref id="ref148"><label>148.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Chiang</surname> <given-names>CC</given-names></name> <name><surname>Chuang</surname> <given-names>CC</given-names></name> <name><surname>Ni</surname> <given-names>YC</given-names></name> <name><surname>Jan</surname> <given-names>ML</given-names></name> <name><surname>Chuang</surname> <given-names>KS</given-names></name> <name><surname>Lin</surname> <given-names>HH</given-names></name></person-group>. <article-title>Time of flight dual photon emission computed tomography</article-title>. <source>Sci Rep</source>. (<year>2020</year>) <volume>10</volume>:<fpage>19514</fpage>&#x2013;<lpage>3</lpage>. doi: <pub-id pub-id-type="doi">10.1038/s41598-020-76526-z</pub-id>, PMID: <pub-id pub-id-type="pmid">33177616</pub-id></mixed-citation></ref>
<ref id="ref149"><label>149.</label><mixed-citation publication-type="book"><person-group person-group-type="author"><name><surname>Liu</surname> <given-names>X</given-names></name> <name><surname>Liu</surname> <given-names>H</given-names></name> <name><surname>Cheng</surname> <given-names>L</given-names></name> <name><surname>Gu</surname> <given-names>Z</given-names></name> <name><surname>Yao</surname> <given-names>RT</given-names></name> <name><surname>Liu</surname> <given-names>YQ</given-names></name> <etal/></person-group>. <article-title>An MLEM reconstruction method with mixed events based on a cascade gamma emission imager system</article-title> In: <source>2020 IEEE Nucl Sci Symp med imaging Conf (NSS/MIC); 2020 Oct 31-Nov 7; Boston, MA(USA)</source>. <publisher-loc>Piscataway, NJ</publisher-loc>: <publisher-name>IEEE</publisher-name> (<year>2020</year>). <fpage>1</fpage>&#x2013;<lpage>3</lpage>.</mixed-citation></ref>
<ref id="ref150"><label>150.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Liu</surname> <given-names>X</given-names></name> <name><surname>Liu</surname> <given-names>H</given-names></name> <name><surname>Cheng</surname> <given-names>L</given-names></name> <name><surname>Wu</surname> <given-names>J</given-names></name> <name><surname>Bao</surname> <given-names>T</given-names></name> <name><surname>Yao</surname> <given-names>R</given-names></name> <etal/></person-group>. <article-title>A 3-dimensional stationary cascade gamma-ray coincidence imager</article-title>. <source>Phys Med Biol</source>. (<year>2021</year>) <volume>66</volume>:<fpage>225001</fpage>. doi: <pub-id pub-id-type="doi">10.1088/1361-6560/ac311b</pub-id>, PMID: <pub-id pub-id-type="pmid">34666327</pub-id></mixed-citation></ref>
<ref id="ref151"><label>151.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Seifert</surname> <given-names>R</given-names></name> <name><surname>Weber</surname> <given-names>M</given-names></name> <name><surname>Kocakavuk</surname> <given-names>E</given-names></name> <name><surname>Rischpler</surname> <given-names>C</given-names></name> <name><surname>Kersting</surname> <given-names>D</given-names></name></person-group>. <article-title>Artificial intelligence and machine learning in nuclear medicine: future perspectives</article-title>. <source>Semin Nucl Med</source>. (<year>2021</year>) <volume>51</volume>:<fpage>170</fpage>&#x2013;<lpage>7</lpage>. doi: <pub-id pub-id-type="doi">10.1053/j.semnuclmed.2020.08.003</pub-id>, PMID: <pub-id pub-id-type="pmid">33509373</pub-id></mixed-citation></ref>
<ref id="ref152"><label>152.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Strosberg</surname> <given-names>J</given-names></name> <name><surname>El-Haddad</surname> <given-names>G</given-names></name> <name><surname>Wolin</surname> <given-names>E</given-names></name> <name><surname>Hendifar</surname> <given-names>A</given-names></name> <name><surname>Yao</surname> <given-names>J</given-names></name> <name><surname>Chasen</surname> <given-names>B</given-names></name> <etal/></person-group>. <article-title>Phase 3 trial of 177Lu-dotatate for midgut neuroendocrine tumors</article-title>. <source>N Engl J Med</source>. (<year>2017</year>) <volume>376</volume>:<fpage>125</fpage>&#x2013;<lpage>35</lpage>. doi: <pub-id pub-id-type="doi">10.1056/NEJMoa1607427</pub-id>, PMID: <pub-id pub-id-type="pmid">28076709</pub-id></mixed-citation></ref>
<ref id="ref153"><label>153.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Fallah</surname> <given-names>J</given-names></name> <name><surname>Agrawal</surname> <given-names>S</given-names></name> <name><surname>Gittleman</surname> <given-names>H</given-names></name> <name><surname>Fiero</surname> <given-names>MH</given-names></name> <name><surname>Subramaniam</surname> <given-names>S</given-names></name> <name><surname>John</surname> <given-names>C</given-names></name> <etal/></person-group>. <article-title>FDA approval summary: lutetium Lu 177 vipivotide tetraxetan for patients with metastatic castration-resistant prostate cancer</article-title>. <source>Clin Cancer Res</source>. (<year>2023</year>) <volume>29</volume>:<fpage>1651</fpage>&#x2013;<lpage>7</lpage>. doi: <pub-id pub-id-type="doi">10.1158/1078-0432.CCR-22-2875</pub-id>, PMID: <pub-id pub-id-type="pmid">36469000</pub-id></mixed-citation></ref>
<ref id="ref154"><label>154.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Conti</surname> <given-names>M</given-names></name> <name><surname>Eriksson</surname> <given-names>L</given-names></name></person-group>. <article-title>Physics of pure and non-pure positron emitters for PET: a review and a discussion</article-title>. <source>EJNMMI Phys</source>. (<year>2016</year>) <volume>3</volume>:<fpage>8</fpage>&#x2013;<lpage>17</lpage>. doi: <pub-id pub-id-type="doi">10.1186/s40658-016-0144-5</pub-id>, PMID: <pub-id pub-id-type="pmid">27271304</pub-id></mixed-citation></ref>
<ref id="ref155"><label>155.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Kwon</surname> <given-names>K</given-names></name> <name><surname>Oh</surname> <given-names>D</given-names></name> <name><surname>Kim</surname> <given-names>JH</given-names></name> <name><surname>Yoo</surname> <given-names>J</given-names></name> <name><surname>Lee</surname> <given-names>WW</given-names></name></person-group>. <article-title>Deep-learning-based attenuation map generation in kidney single photon emission computed tomography</article-title>. <source>EJNMMI Phys</source>. (<year>2024</year>) <volume>11</volume>:<fpage>84</fpage>. doi: <pub-id pub-id-type="doi">10.1186/s40658-024-00686-4</pub-id>, PMID: <pub-id pub-id-type="pmid">39394395</pub-id></mixed-citation></ref>
<ref id="ref156"><label>156.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>McMillan</surname> <given-names>AB</given-names></name> <name><surname>Bradshaw</surname> <given-names>TJ</given-names></name></person-group>. <article-title>AI-based data corrections for attenuation and scatter in position emission tomography and single-photon emission computed tomography</article-title>. <source>PET Clin</source>. (<year>2021</year>) <volume>16</volume>:<fpage>543</fpage>&#x2013;<lpage>52</lpage>. doi: <pub-id pub-id-type="doi">10.1016/j.cpet.2021.06.010</pub-id>, PMID: <pub-id pub-id-type="pmid">34364816</pub-id></mixed-citation></ref>
<ref id="ref157"><label>157.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Loft</surname> <given-names>M</given-names></name> <name><surname>Ladefoged</surname> <given-names>CN</given-names></name> <name><surname>Johnbeck</surname> <given-names>CB</given-names></name> <name><surname>Carlsen</surname> <given-names>EA</given-names></name> <name><surname>Oturai</surname> <given-names>P</given-names></name> <name><surname>Langer</surname> <given-names>SW</given-names></name> <etal/></person-group>. <article-title>An investigation of lesion detection accuracy for artificial intelligence-based denoising of low-dose 64Cu-DOTATATE PET imaging in patients with neuroendocrine neoplasms</article-title>. <source>J Nucl Med</source>. (<year>2023</year>) <volume>64</volume>:<fpage>951</fpage>&#x2013;<lpage>9</lpage>. doi: <pub-id pub-id-type="doi">10.2967/jnumed.122.264826</pub-id>, PMID: <pub-id pub-id-type="pmid">37169532</pub-id></mixed-citation></ref>
<ref id="ref158"><label>158.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Khalifa</surname> <given-names>M</given-names></name> <name><surname>Albadawy</surname> <given-names>M</given-names></name></person-group>. <article-title>AI in diagnostic imaging: revolutionising accuracy and efficiency</article-title>. <source>Comput Methods Programs Biomed Update</source>. (<year>2024</year>) <volume>5</volume>:<fpage>100146</fpage>. doi: <pub-id pub-id-type="doi">10.1016/j.cmpbup.2024.100146</pub-id></mixed-citation></ref>
</ref-list>
<fn-group>
<fn fn-type="custom" custom-type="edited-by" id="fn0001">
<p>Edited by: <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/3147514/overview">Yongfeng Yang</ext-link>, University of Chinese Academy of Sciences, China</p>
</fn>
<fn fn-type="custom" custom-type="reviewed-by" id="fn0002">
<p>Reviewed by: <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1131569/overview">Roberto Massari</ext-link>, National Research Council (CNR), Italy</p>
<p><ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/3153556/overview">Xianchao Huang</ext-link>, Chinese Academy of Sciences (CAS), China</p>
<p><ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/3154724/overview">Jianyong Jiang</ext-link>, Beijing Normal University, China</p>
</fn>
</fn-group>
</back>
</article>