<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Med.</journal-id>
<journal-title>Frontiers in Medicine</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Med.</abbrev-journal-title>
<issn pub-type="epub">2296-858X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fmed.2025.1495527</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Medicine</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Factors influencing image quality in Tibetan children by optical coherence tomography</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name><surname>Yao</surname> <given-names>Yao</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/2841713/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/data-curation/"/>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Liu</surname> <given-names>Jiawen</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Li</surname> <given-names>Lei</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Chen</surname> <given-names>Weiwei</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/data-curation/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/project-administration/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Meng</surname> <given-names>Zhaojun</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/2929388/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/data-curation/"/>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/>
<role content-type="https://credit.niso.org/contributor-roles/project-administration/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name><surname>Fu</surname> <given-names>Jing</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="corresp" rid="c001"><sup>&#x002A;</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/funding-acquisition/"/>
<role content-type="https://credit.niso.org/contributor-roles/project-administration/"/>
<role content-type="https://credit.niso.org/contributor-roles/supervision/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
</contrib>
</contrib-group>
<aff id="aff1"><sup>1</sup><institution>Beijing Key Laboratory of Ophthalmology and Visual Sciences, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University</institution>, <addr-line>Beijing</addr-line>, <country>China</country></aff>
<aff id="aff2"><sup>2</sup><institution>Wilmer Eye Institute, Johns Hopkins Medicine, Johns Hopkins University</institution>, <addr-line>Baltimore, MD</addr-line>, <country>United States</country></aff>
<author-notes>
<fn fn-type="edited-by"><p>Edited by: Changzheng Chen, Renmin Hospital of Wuhan University, China</p></fn>
<fn fn-type="edited-by"><p>Reviewed by: Bhim Bahadur Rai, The Australian National University, Australia</p>
<p>Jing Ji Ji, Shanghai Ninth People&#x2019;s Hospital, China</p></fn>
<corresp id="c001">&#x002A;Correspondence: Jing Fu, <email>fu_jing@126.com</email></corresp>
</author-notes>
<pub-date pub-type="epub">
<day>17</day>
<month>01</month>
<year>2025</year>
</pub-date>
<pub-date pub-type="collection">
<year>2025</year>
</pub-date>
<volume>12</volume>
<elocation-id>1495527</elocation-id>
<history>
<date date-type="received">
<day>12</day>
<month>09</month>
<year>2024</year>
</date>
<date date-type="accepted">
<day>02</day>
<month>01</month>
<year>2025</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x00A9; 2025 Yao, Liu, Li, Chen, Meng and Fu.</copyright-statement>
<copyright-year>2025</copyright-year>
<copyright-holder>Yao, Liu, Li, Chen, Meng and Fu</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license>
</permissions>
<abstract>
<sec>
<title>Purpose</title>
<p>This study aim to investigate the clinical findings of subjects characteristics and image quality related factors in Tibetan children by optical coherence tomography (OCT) in epidemiological cohort study.</p>
</sec>
<sec>
<title>Methods</title>
<p>Participants were 1,856 first-grade students (mean age = 6.82 &#x00B1; 0.46 years) from seven selected elementary schools in Lhasa. Following comprehensive systemic and ophthalmic examinations, OCT scans were assessed by specialists with manual segmentation as needed.</p>
</sec>
<sec>
<title>Results</title>
<p>A total of 1,698 students completed the examination protocol in this study (91.5%). After manual screening, 1,447 (78%) and 1,289 (70%) images could be analyzed in the macular and optic disc regions, respectively. Common image flaws were blinking or fixation error (70%+), poor focusing, and positioning errors. Among students who have completed OCT, a higher percentage of boys (<italic>X</italic><sup>2</sup> = 8.48, <italic>P</italic> = 0.004) and suburban students (<italic>X</italic><sup>2</sup> = 34.97, <italic>P</italic> &#x003C; 0.001) with younger age (<italic>t</italic> = -2.20, <italic>P</italic> = 0.03), worse near vision (<italic>t</italic> = -3.95, <italic>P</italic> &#x003C; 0.001), higher IOP (<italic>t</italic> = 2.38, <italic>P</italic> = 0.017) and higher heart rate (<italic>t</italic> = 3.15, <italic>P</italic> = 0.002) have unsatisfactory image quality in the macular region, almost same as the optic disc region. Students in suburban schools (OR = 1.74, <italic>P</italic> &#x003C; 0.001) with lower near VA (OR = 6.64, <italic>P</italic> &#x003C; 0.001) or boys (OR = 0.78, <italic>P</italic> = 0.03) were more likely to have worse image quality on OCT scans when corrected for ethnicity. Manual segmentation was more prevalent in the optic disc region, resulting in increased retinal thickness across most subregions.</p>
</sec>
<sec>
<title>Conclusion</title>
<p>This study underscores the imperative for stringent image quality control in pediatric OCT assessments to ensure precise clinical outcomes.</p>
</sec>
</abstract>
<kwd-group>
<kwd>optical coherence tomography</kwd>
<kwd>image quality</kwd>
<kwd>children</kwd>
<kwd>Tibetan</kwd>
<kwd>clinical reliability</kwd>
</kwd-group>
<counts>
<fig-count count="3"/>
<table-count count="4"/>
<equation-count count="0"/>
<ref-count count="31"/>
<page-count count="10"/>
<word-count count="5609"/>
</counts>
<custom-meta-wrap>
<custom-meta>
<meta-name>section-at-acceptance</meta-name>
<meta-value>Ophthalmology</meta-value>
</custom-meta>
</custom-meta-wrap>
</article-meta>
</front>
<body>
<sec id="S1" sec-type="intro">
<title>Introduction</title>
<p>Optical coherence tomography (OCT) constitutes a non-invasive and well-tolerated imaging modality leveraging low coherence light reflected by ocular tissues to generate high-resolution images (<xref ref-type="bibr" rid="B1">1</xref>). This technique empowers clinicians to produce three-dimensional (3D) renderings of intraocular structures <italic>in vivo</italic> (<xref ref-type="bibr" rid="B2">2</xref>, <xref ref-type="bibr" rid="B3">3</xref>). Beyond subjective qualitative assessment, these images lend themselves to objective analysis, facilitating quantitative measurements such as stratified retinal thickness across distinct retinal zones (<xref ref-type="bibr" rid="B4">4</xref>, <xref ref-type="bibr" rid="B5">5</xref>). With advancements in image resolution, quality, and software capabilities, the quantitative scrutiny of OCT images has undergone significant refinement (<xref ref-type="bibr" rid="B6">6</xref>, <xref ref-type="bibr" rid="B7">7</xref>). The faster scanning speed and higher imaging quality allow it to be performed also in patients with poor cooperation (e.g., children) (<xref ref-type="bibr" rid="B8">8</xref>&#x2013;<xref ref-type="bibr" rid="B10">10</xref>). Although the accuracy and reproducibility of OCT applications in pediatric contexts have undergone scrutiny, empirical evidence validating its clinical utility across diverse demographics remains lacking (<xref ref-type="bibr" rid="B11">11</xref>).</p>
<p>Precise and highly reproducible quantitative measurements serve as indispensable diagnostic and monitoring tools, guiding optimal treatment decisions across routine medical care and clinical trials alike. However, the variance in measurement values among different OCT instruments underscores the need for standardized algorithms for image recognition and segmentation (<xref ref-type="bibr" rid="B12">12</xref>). The application of OCT in pediatric cohorts introduces additional intricacies, owing to factors such as limited patient cooperation, diminutive ocular dimensions, and the imperative of precise image alignment and interpretation (<xref ref-type="bibr" rid="B11">11</xref>, <xref ref-type="bibr" rid="B13">13</xref>). Despite these hurdles, OCT holds immense promise as a non-invasive, objective tool for delineating ocular morphology and pathology in children. A nuanced understanding of the determinants of successful OCT imaging and the factors shaping image quality is imperative for refining screening protocols, augmenting diagnostic precision, and guiding public health initiatives geared toward pediatric ocular wellness.</p>
<p>The Lhasa Childhood Eye Study (LCES) represents a pioneering effort, aiming to investigate the clinical findings of subject characteristics and factors influencing image quality in Tibetan children using OCT within an epidemiological cohort setting. The unique demographic and environmental characteristics of the Tibetan population, coupled with the challenges inherent in conducting large-scale pediatric ocular screenings in resource-limited settings, underscore the significance of this study. Through a comprehensive approach encompassing clinical examination, OCT imaging, and systemic evaluation, this study seeks to elucidate the epidemiology of ocular conditions, identify risk factors for poor image quality in OCT, and inform strategies for improving the efficiency and effectiveness of pediatric ocular screening programs.</p>
</sec>
<sec id="S2" sec-type="materials|methods">
<title>Materials and methods</title>
<sec id="S2.SS1">
<title>Study design and population</title>
<p>The LCES constituted a school-based, observational cohort epidemiological inquiry into childhood ocular ailments (<xref ref-type="bibr" rid="B14">14</xref>). The study protocol adhered to the principles of the Declaration of Helsinki and obtained approval from the Ethics Committee of the Beijing Tongren Hospital, Capital Medical University (No. TRECKY2019-058). Written informed consent was provided by all participants&#x2019; parents or legal guardians. The LCES employed stratified cluster sampling among grade one students in Lhasa, Tibet, located in the southwest of China. Following local government assessment, 27 out of 28 elementary schools effectively participating in the LCES were stratified into three tiers. Ultimately, seven elementary schools were randomly selected as samples, encompassing 1,942 grade 1 students through stratified cluster sampling. The study commenced in 2019 and will continue for an additional 5 years until the students transition to junior high school.</p>
</sec>
<sec id="S2.SS2">
<title>Study protocols and examination methods</title>
<p>All participants underwent comprehensive ophthalmic examinations, encompassing evaluations of uncorrected and best-corrected visual acuity (BCVA), near visual acuity (VA), stereopsis acuity (S0001, STEREO, USA), ocular dominance, slit-lamp biomicroscopy assessment (SL-3G, Topcon, Tokyo, Japan), non-contact tonometry (CT-800, Topcon, Tokyo, Japan), ocular alignment, and objective refraction measurement before and after cycloplegia, in addition to OCT and retinal photography.</p>
<p>Anthropometric parameters such as body height and weight, blood oxygen saturation, and heart rate were also assessed. Body mass index (BMI), calculated as the ratio of body weight (kg) divided by the square of body height (m), served as a measure of body composition. Oxygen saturation and heart rate were measured twice using a digital fingertip pulse oximeter, with the average value utilized for statistical analysis.</p>
</sec>
<sec id="S2.SS3">
<title>OCT measurements</title>
<p>Optical coherence tomography examination was conducted by a certified and experienced technician utilizing spectral-domain OCT (3D OCT-1, Topcon, Tokyo, Japan). The Topcon 3D OCT-1 is a non-contact SD-OCT system renowned for its capability to perform a fully automated &#x201C;alignment, focus, and capture&#x201D; procedure, capturing an impressive 50,000 axial scans per second (<xref ref-type="bibr" rid="B15">15</xref>, <xref ref-type="bibr" rid="B16">16</xref>). In this study, we opted for the &#x201C;3D wide scan mode,&#x201D; which entails a 12 mm &#x00D7; 9 mm scan (<xref ref-type="fig" rid="F1">Figure 1A</xref>), providing detailed measurement and topographical maps of the optic nerve and macula (<xref ref-type="fig" rid="F1">Figures 1B, C</xref>). Recognizing the influence of circadian rhythms and cycloplegia on choroidal thickness, all examinations were conducted prior to cycloplegia, specifically between 1 p.m. and 4 p.m.</p>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption><p>The 12 mm &#x00D7; 9 mm scan region <bold>(A)</bold>; Measurement areas for circumpapillary circle <bold>(B)</bold>; macular grid <bold>(C)</bold> overlaid with example projected images. T, temporal; S, superior; N, nasal; I, inferior.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmed-12-1495527-g001.tif"/>
</fig>
<p>To acquire optic nerve head parameters, a 3.4 mm diameter temporal-superior-nasal-inferior-temporal (TSNIT) circle was automatically positioned at the center of the optic disc. Circumpapillary retinal nerve fiber layer (cpRNFL) thickness was evaluated across 4 quadrants and 12 clock-hour sectors around the TSNIT circle (<xref ref-type="fig" rid="F1">Figure 1B</xref>). Macular full retinal thickness (FRT) was determined as the distance between the inner limiting membrane (ILM) and the boundary of the outer segments/retinal pigment epithelium, delineated according to the Early Treatment Diabetic Retinopathy Study (ETDRS) map, with its nine quadrants illustrated in <xref ref-type="fig" rid="F1">Figure 1C</xref>. The diameters of the three circles on the ETDRS map were 1, 3, and 6 mm.</p>
<p>In this study, image quality was categorized as &#x201C;Qualified,&#x201D; &#x201C;Acceptable,&#x201D; and &#x201C;Unqualified&#x201D; in accordance with the OSCAR-IB consensus criteria for retinal OCT quality assessment (<xref ref-type="bibr" rid="B15">15</xref>). Qualified images met criteria such as signal strength exceeding 6 (out of a maximum of 10), centered image scanning position, and absence of other quality issues. Unqualified images exhibited significant exposure abnormalities, refractive interstitial turbidities, extensive contamination, missing information, or irrelevant images. Acceptable images presented minor exposure issues, limited contaminations with negligible impact on interpretation, slight out-of-focus or blurred characteristics, among others. In cases of automatic segmentation errors related to foveal centration, boundary segmentations, or disc margin in fast maps, manual segmentation was executed based on anatomical considerations (<xref ref-type="bibr" rid="B11">11</xref>, <xref ref-type="bibr" rid="B17">17</xref>). Foveal modification involved the relocation of the ETDRS and Macula 6 grid center location, while adjustments to the disc margin and center corresponded to alterations in the disc outline and location, respectively. Other modifications encompassed segmentation adjustments between boundaries (<xref ref-type="bibr" rid="B16">16</xref>). Evaluation of all collected images was performed by Yao Yao, with clinical data and medical records withheld during the grading process. Image enhancement tools were not utilized. In instances of ambiguity, a panel of ophthalmologists (Jing Fu and Zhaojun Meng) reassessed the OCT images to reach a consensus. All manual segmentation was electronically documented, and images from the right eye were utilized for analysis in the present study.</p>
</sec>
<sec id="S2.SS4">
<title>Statistical analysis</title>
<p>Values were presented as mean &#x00B1; standard deviation (SD) for continuous variables and as percentage for categorical variables. All data was analyzed using Statistical Analysis System software (version 9.4, SAS Inc., Cary, NC, USA). Independent samples <italic>t</italic>-tests were utilized to compare the differences in systemic and ocular influencing factors among different OCT completion status groups. Chi-square tests were employed to assess differences in gender, school location, ethnicity, and amblyopia among groups. Multivariate logistic analysis was conducted to evaluate the influence of various related factors on OCT image completion and quality. Paired <italic>t</italic>-tests were employed to compare differences in quantitative measurement values of OCT images before and after manual adjustments. A two-tailed <italic>P</italic>-value of less than 0.05 was defined as statistically significant at the 95% confidence interval level.</p>
</sec>
</sec>
<sec id="S3" sec-type="results">
<title>Results</title>
<sec id="S3.SS1">
<title>Study population and general characteristics</title>
<p>A total of 1,856 subjects were enrolled in the first year of LCES, with a mean age of 6.82 &#x00B1; 0.46 years. Notably, 53% of the included students were male, while 94% were Tibetan. Demographic data of the cohort are shown in <xref ref-type="table" rid="T1">Table 1</xref>. There were 150 participants who failed to complete protocols or examine procedures and 8 had ocular diseases who could not complete the OCT scans, giving an analyzable fraction of 91.5%. The average abxge of students performed OCT assessment was 6.83 &#x00B1; 0.46 years, 53.02% of the participants were boy, 94.93% were Tibetan minority.</p>
<table-wrap position="float" id="T1">
<label>TABLE 1</label>
<caption><p>Systemic parameters of the study population.</p></caption>
<table cellspacing="5" cellpadding="5" frame="box" rules="all">
<thead>
<tr>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;">Parameters</td>
<td valign="top" align="center" style="color:#ffffff;background-color: #7f8080;">Mean</td>
<td valign="top" align="center" style="color:#ffffff;background-color: #7f8080;">SD</td>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Visual acuity</td>
<td valign="top" align="center">0.11</td>
<td valign="top" align="center">0.19</td>
</tr>
<tr>
<td valign="top" align="left">Near visual acuity</td>
<td valign="top" align="center">&#x2212;0.16</td>
<td valign="top" align="center">0.14</td>
</tr>
<tr>
<td valign="top" align="left">Intraocular pressure, mmHg</td>
<td valign="top" align="center">16.02</td>
<td valign="top" align="center">2.73</td>
</tr>
<tr>
<td valign="top" align="left">Height, cm</td>
<td valign="top" align="center">120.55</td>
<td valign="top" align="center">5.52</td>
</tr>
<tr>
<td valign="top" align="left">Weight, kg</td>
<td valign="top" align="center">22.96</td>
<td valign="top" align="center">3.69</td>
</tr>
<tr>
<td valign="top" align="left">Body mass index, kg/m<sup>2</sup></td>
<td valign="top" align="center">15.74</td>
<td valign="top" align="center">1.80</td>
</tr>
<tr>
<td valign="top" align="left">Heart rate</td>
<td valign="top" align="center">95.27</td>
<td valign="top" align="center">14.27</td>
</tr>
<tr>
<td valign="top" align="left">Systolic blood pressure, mmHg</td>
<td valign="top" align="center">95.67</td>
<td valign="top" align="center">7.99</td>
</tr>
<tr>
<td valign="top" align="left">Diastolic blood pressure, mmHg</td>
<td valign="top" align="center">64.68</td>
<td valign="top" align="center">6.57</td>
</tr>
<tr>
<td valign="top" align="left">Mean arterial blood pressure, mmHg</td>
<td valign="top" align="center">85.34</td>
<td valign="top" align="center">6.65</td>
</tr>
<tr>
<td valign="top" align="left">Blood oxygen saturation, %</td>
<td valign="top" align="center">92.68</td>
<td valign="top" align="center">3.07</td>
</tr>
<tr>
<td valign="top" align="left">Spherical equivalent, D</td>
<td valign="top" align="center">1.07</td>
<td valign="top" align="center">0.92</td>
</tr>
<tr>
<td valign="top" align="left">Best-corrected visual acuity</td>
<td valign="top" align="center">0.03</td>
<td valign="top" align="center">0.10</td>
</tr>
<tr>
<td valign="top" align="left">Age</td>
<td valign="top" align="center">6.82</td>
<td valign="top" align="center">0.46</td>
</tr>
</tbody>
</table></table-wrap>
</sec>
<sec id="S3.SS2">
<title>Image enrollment and screening</title>
<p>After manual segmentation, another 268 scans in the macula area and 490 scans in the optic disc area which did not meet the image criteria were excluded, respectively. We were ultimately left with 1,447 macular scans (78%) and 1,289 (70%) optic disc scans. The enrollment and screening process for this study is shown in <xref ref-type="fig" rid="F2">Figure 2</xref>. Of the failed images, the most common cause was scanned image defects due to blinking or fixation error (over 70%), followed by image blurring due to poor focusing and uncorrectable image positioning errors.</p>
<fig id="F2" position="float">
<label>FIGURE 2</label>
<caption><p>Inclusion and exclusion of study participants.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmed-12-1495527-g002.tif"/>
</fig>
</sec>
<sec id="S3.SS3">
<title>Retinal thickness and distribution of macula and cpRNFL</title>
<p><xref ref-type="table" rid="T2">Table 2</xref> showed the thickness and distribution of the macula and cpRNFL before and after the manual adjustment. The average retinal thickness of macula was 278.57 &#x00B1; 13.40 &#x03BC;m before the manual segmentation and 279.08 &#x00B1; 11.06 &#x03BC;m after that. In the inner circle of macular full retina, the superior region is the thickest area, followed by the inferior, nasal and temporal regions. In the outer ring, the nasal region was the thickest, followed by the superior, inferior and temporal regions. While the average thickness of cpRNFL was 101.58 &#x00B1; 27.20 and 112.39 &#x00B1; 12.31 &#x03BC;m before and after the adjustment, respectively. The thickest area was the inferior region, followed by the superior, the temporal and the nasal quadrants. The cpRNFL thickness in the 12 sections is more discrete than the 4 sections.</p>
<table-wrap position="float" id="T2">
<label>TABLE 2</label>
<caption><p>Optical coherence tomography parameters before and after the manual segmentation.</p></caption>
<table cellspacing="5" cellpadding="5" frame="box" rules="all">
<thead>
<tr>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;"></td>
<td valign="top" align="center" style="color:#ffffff;background-color: #7f8080;">Mean</td>
<td valign="top" align="center" style="color:#ffffff;background-color: #7f8080;">SD</td>
<td valign="top" align="center" style="color:#ffffff;background-color: #7f8080;"></td>
<td valign="top" align="center" style="color:#ffffff;background-color: #7f8080;">Mean</td>
<td valign="top" align="center" style="color:#ffffff;background-color: #7f8080;">SD</td>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Macular (1,698), mm</td>
<td/>
<td/>
<td valign="top" align="center">After adjustment (1,447)</td>
<td/>
<td/>
</tr>
<tr>
<td valign="top" align="left">Average</td>
<td valign="top" align="center">278.57</td>
<td valign="top" align="center">13.40</td>
<td valign="top" align="center">Average</td>
<td valign="top" align="center">279.08</td>
<td valign="top" align="center">11.06</td>
</tr>
<tr>
<td valign="top" align="left">Foveal minimum</td>
<td valign="top" align="center">171.90</td>
<td valign="top" align="center">29.00</td>
<td valign="top" align="center">Foveal minimum</td>
<td valign="top" align="center">168.44</td>
<td valign="top" align="center">16.80</td>
</tr>
<tr>
<td valign="top" align="left">Center</td>
<td valign="top" align="center">205.24</td>
<td valign="top" align="center">25.90</td>
<td valign="top" align="center">Center</td>
<td valign="top" align="center">201.75</td>
<td valign="top" align="center">18.14</td>
</tr>
<tr>
<td valign="top" align="left">Inner temporal</td>
<td valign="top" align="center">287.71</td>
<td valign="top" align="center">22.85</td>
<td valign="top" align="center">Inner temporal</td>
<td valign="top" align="center">289.48</td>
<td valign="top" align="center">13.31</td>
</tr>
<tr>
<td valign="top" align="left">Inner superior</td>
<td valign="top" align="center">304.49</td>
<td valign="top" align="center">16.43</td>
<td valign="top" align="center">Inner superior</td>
<td valign="top" align="center">305.50</td>
<td valign="top" align="center">12.66</td>
</tr>
<tr>
<td valign="top" align="left">Inner nasal</td>
<td valign="top" align="center">294.12</td>
<td valign="top" align="center">20.72</td>
<td valign="top" align="center">Inner nasal</td>
<td valign="top" align="center">295.70</td>
<td valign="top" align="center">16.55</td>
</tr>
<tr>
<td valign="top" align="left">Inner inferior</td>
<td valign="top" align="center">300.89</td>
<td valign="top" align="center">17.09</td>
<td valign="top" align="center">Inner inferior</td>
<td valign="top" align="center">301.74</td>
<td valign="top" align="center">12.62</td>
</tr>
<tr>
<td valign="top" align="left">Outer temporal</td>
<td valign="top" align="center">264.57</td>
<td valign="top" align="center">27.05</td>
<td valign="top" align="center">Outer temporal</td>
<td valign="top" align="center">265.46</td>
<td valign="top" align="center">14.91</td>
</tr>
<tr>
<td valign="top" align="left">Outer superior</td>
<td valign="top" align="center">276.34</td>
<td valign="top" align="center">14.20</td>
<td valign="top" align="center">Outer superior</td>
<td valign="top" align="center">277.12</td>
<td valign="top" align="center">12.27</td>
</tr>
<tr>
<td valign="top" align="left">Outer nasal</td>
<td valign="top" align="center">295.25</td>
<td valign="top" align="center">17.45</td>
<td valign="top" align="center">Outer nasal</td>
<td valign="top" align="center">295.63</td>
<td valign="top" align="center">13.57</td>
</tr>
<tr>
<td valign="top" align="left">Outer inferior</td>
<td valign="top" align="center">267.04</td>
<td valign="top" align="center">14.96</td>
<td valign="top" align="center">Outer inferior</td>
<td valign="top" align="center">266.88</td>
<td valign="top" align="center">12.13</td>
</tr>
<tr>
<td valign="top" align="left">Total volume (mm<sup>3</sup>)</td>
<td valign="top" align="center">7.87</td>
<td valign="top" align="center">0.38</td>
<td valign="top" align="center">Total volume (mm<sup>3</sup>)</td>
<td valign="top" align="center">7.89</td>
<td valign="top" align="center">0.31</td>
</tr>
<tr>
<td valign="top" align="left">Optic disc (1,698), mm</td>
<td/>
<td/>
<td valign="top" align="center">After adjustment (1,289)</td>
<td/>
<td/>
</tr>
<tr>
<td valign="top" align="left">Global average</td>
<td valign="top" align="center">101.58</td>
<td valign="top" align="center">27.20</td>
<td valign="top" align="center">Global average</td>
<td valign="top" align="center">112.39</td>
<td valign="top" align="center">13.31</td>
</tr>
<tr>
<td valign="top" align="left">Temporal</td>
<td valign="top" align="center">70.39</td>
<td valign="top" align="center">25.08</td>
<td valign="top" align="center">Temporal</td>
<td valign="top" align="center">79.60</td>
<td valign="top" align="center">13.80</td>
</tr>
<tr>
<td valign="top" align="left">Superior</td>
<td valign="top" align="center">130.07</td>
<td valign="top" align="center">37.05</td>
<td valign="top" align="center">Superior</td>
<td valign="top" align="center">144.25</td>
<td valign="top" align="center">19.40</td>
</tr>
<tr>
<td valign="top" align="left">Nasal</td>
<td valign="top" align="center">76.01</td>
<td valign="top" align="center">25.95</td>
<td valign="top" align="center">Nasal</td>
<td valign="top" align="center">79.24</td>
<td valign="top" align="center">16.46</td>
</tr>
<tr>
<td valign="top" align="left">Inferior</td>
<td valign="top" align="center">129.65</td>
<td valign="top" align="center">40.90</td>
<td valign="top" align="center">Inferior</td>
<td valign="top" align="center">146.34</td>
<td valign="top" align="center">20.58</td>
</tr>
<tr>
<td valign="top" align="left">9 o&#x2019;clock</td>
<td valign="top" align="center">56.13</td>
<td valign="top" align="center">20.55</td>
<td valign="top" align="center">9 o&#x2019;clock</td>
<td valign="top" align="center">63.08</td>
<td valign="top" align="center">12.03</td>
</tr>
<tr>
<td valign="top" align="left">10 o&#x2019;clock</td>
<td valign="top" align="center">82.98</td>
<td valign="top" align="center">30.24</td>
<td valign="top" align="center">10 o&#x2019;clock</td>
<td valign="top" align="center">94.06</td>
<td valign="top" align="center">18.00</td>
</tr>
<tr>
<td valign="top" align="left">11 o&#x2019;clock</td>
<td valign="top" align="center">131.25</td>
<td valign="top" align="center">45.71</td>
<td valign="top" align="center">11 o&#x2019;clock</td>
<td valign="top" align="center">149.58</td>
<td valign="top" align="center">25.51</td>
</tr>
<tr>
<td valign="top" align="left">12 o&#x2019;clock</td>
<td valign="top" align="center">138.34</td>
<td valign="top" align="center">43.71</td>
<td valign="top" align="center">12 o&#x2019;clock</td>
<td valign="top" align="center">152.56</td>
<td valign="top" align="center">26.98</td>
</tr>
<tr>
<td valign="top" align="left">1 o&#x2019;clock</td>
<td valign="top" align="center">120.57</td>
<td valign="top" align="center">37.47</td>
<td valign="top" align="center">1 o&#x2019;clock</td>
<td valign="top" align="center">130.60</td>
<td valign="top" align="center">24.42</td>
</tr>
<tr>
<td valign="top" align="left">2 o&#x2019;clock</td>
<td valign="top" align="center">93.95</td>
<td valign="top" align="center">32.36</td>
<td valign="top" align="center">2 o&#x2019;clock</td>
<td valign="top" align="center">99.45</td>
<td valign="top" align="center">22.83</td>
</tr>
<tr>
<td valign="top" align="left">3 o&#x2019;clock</td>
<td valign="top" align="center">60.35</td>
<td valign="top" align="center">24.14</td>
<td valign="top" align="center">3 o&#x2019;clock</td>
<td valign="top" align="center">61.45</td>
<td valign="top" align="center">15.07</td>
</tr>
<tr>
<td valign="top" align="left">4 o&#x2019;clock</td>
<td valign="top" align="center">73.57</td>
<td valign="top" align="center">30.13</td>
<td valign="top" align="center">4 o&#x2019;clock</td>
<td valign="top" align="center">76.82</td>
<td valign="top" align="center">20.56</td>
</tr>
<tr>
<td valign="top" align="left">5 o&#x2019;clock</td>
<td valign="top" align="center">115.16</td>
<td valign="top" align="center">40.41</td>
<td valign="top" align="center">5 o&#x2019;clock</td>
<td valign="top" align="center">127.82</td>
<td valign="top" align="center">25.69</td>
</tr>
<tr>
<td valign="top" align="left">6 o&#x2019;clock</td>
<td valign="top" align="center">143.95</td>
<td valign="top" align="center">49.67</td>
<td valign="top" align="center">6 o&#x2019;clock</td>
<td valign="top" align="center">161.35</td>
<td valign="top" align="center">29.35</td>
</tr>
<tr>
<td valign="top" align="left">7 o&#x2019;clock</td>
<td valign="top" align="center">130.16</td>
<td valign="top" align="center">48.31</td>
<td valign="top" align="center">7 o&#x2019;clock</td>
<td valign="top" align="center">149.84</td>
<td valign="top" align="center">27.11</td>
</tr>
<tr>
<td valign="top" align="left">8 o&#x2019;clock</td>
<td valign="top" align="center">72.09</td>
<td valign="top" align="center">29.38</td>
<td valign="top" align="center">8 o&#x2019;clock</td>
<td valign="top" align="center">81.65</td>
<td valign="top" align="center">17.66</td>
</tr>
</tbody>
</table></table-wrap>
</sec>
<sec id="S3.SS4">
<title>Multivariate analysis of parameters associated with image quality</title>
<p>We compared general systemic and ophthalmic factors in subjects who passed and failed the image quality check. Among students who have completed OCT, a higher percentage of boys (<italic>X</italic><sup>2</sup> = 8.48, <italic>P</italic> = 0.004) and suburban students (<italic>X</italic><sup>2</sup> = 34.97, <italic>P</italic> &#x003C; 0.001) have unsatisfactory image quality. In addition, students with scanned images of poor quality exhibited younger age (<italic>t</italic> = &#x2212;2.20, <italic>P</italic> = 0.03), worse near vision (<italic>t</italic> = &#x2212;3.95, <italic>P</italic> &#x003C; 0.001), higher IOP (<italic>t</italic> = 2.38, <italic>P</italic> = 0.017) and higher heart rate (<italic>t</italic> = 3.15, <italic>P</italic> = 0.002) in the macular region, almost same as the optic disc region (<xref ref-type="supplementary-material" rid="TS1">Supplementary Table 1</xref>). Multivariate logistic regression analysis showed that students in suburban schools (OR = 1.74, <italic>P</italic> &#x003C; 0.001) with lower near VA (OR = 6.64, <italic>P</italic> &#x003C; 0.001) or boys (OR = 0.78, <italic>P</italic> = 0.03) were more likely to have worse image quality on OCT scans when corrected for ethnicity (<xref ref-type="table" rid="T3">Table 3</xref>).</p>
<table-wrap position="float" id="T3">
<label>TABLE 3</label>
<caption><p>Multivariate logistic regression analysis under different groups of OCT examination.</p></caption>
<table cellspacing="5" cellpadding="5" frame="box" rules="all">
<thead>
<tr>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;">Macular</td>
<td valign="top" align="center" style="color:#ffffff;background-color: #7f8080;">Unstandardized coefficient</td>
<td valign="top" align="center" style="color:#ffffff;background-color: #7f8080;"><italic>P-</italic>value</td>
<td valign="top" align="center" style="color:#ffffff;background-color: #7f8080;">Odds ratio</td>
<td valign="top" align="center" style="color:#ffffff;background-color: #7f8080;">95% confidence interval</td>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left" colspan="5" style="background-color: #dcdcdc;"><bold>Whether OCT was completed</bold></td>
</tr>
<tr>
<td valign="top" align="left">Gender</td>
<td valign="top" align="center">&#x2212;0.379</td>
<td valign="top" align="center">0.031</td>
<td valign="top" align="center">0.685</td>
<td valign="top" align="center">0.485, 0.966</td>
</tr>
<tr>
<td valign="top" align="left">School location</td>
<td valign="top" align="center">&#x2212;1.068</td>
<td valign="top" align="center">&#x003C;0.001</td>
<td valign="top" align="center">0.344</td>
<td valign="top" align="center">0.19, 0.622</td>
</tr>
<tr>
<td valign="top" align="left">Amblyopia</td>
<td valign="top" align="center">&#x2212;0.405</td>
<td valign="top" align="center">0.575</td>
<td valign="top" align="center">0.667</td>
<td valign="top" align="center">0.162, 2.747</td>
</tr>
<tr>
<td valign="top" align="left">Near visual acuity</td>
<td valign="top" align="center">1.451</td>
<td valign="top" align="center">0.013</td>
<td valign="top" align="center">4.266</td>
<td valign="top" align="center">1.353, 13.447</td>
</tr>
<tr>
<td valign="top" align="left">Height</td>
<td valign="top" align="center">0.003</td>
<td valign="top" align="center">0.887</td>
<td valign="top" align="center">1.003</td>
<td valign="top" align="center">0.961, 1.047</td>
</tr>
<tr>
<td valign="top" align="left">Weight</td>
<td valign="top" align="center">&#x2212;0.056</td>
<td valign="top" align="center">0.103</td>
<td valign="top" align="center">0.946</td>
<td valign="top" align="center">0.884, 1.011</td>
</tr>
<tr>
<td valign="top" align="left">Visual acuity</td>
<td valign="top" align="center">0.214</td>
<td valign="top" align="center">0.725</td>
<td valign="top" align="center">1.239</td>
<td valign="top" align="center">0.376, 4.089</td>
</tr>
<tr>
<td valign="top" align="left">Best-corrected visual acuity</td>
<td valign="top" align="center">1.926</td>
<td valign="top" align="center">0.129</td>
<td valign="top" align="center">6.863</td>
<td valign="top" align="center">0.573, 82.277</td>
</tr>
<tr>
<td valign="top" align="left" colspan="5" style="background-color: #dcdcdc;"><bold>Whether OCT was deleted</bold></td>
</tr>
<tr>
<td valign="top" align="left">Gender</td>
<td valign="top" align="center">&#x2212;0.392</td>
<td valign="top" align="center">0.005</td>
<td valign="top" align="center">0.676</td>
<td valign="top" align="center">0.515, 0.888</td>
</tr>
<tr>
<td valign="top" align="left">School location</td>
<td valign="top" align="center">0.641</td>
<td valign="top" align="center">&#x003C;0.001</td>
<td valign="top" align="center">1.899</td>
<td valign="top" align="center">1.351, 2.669</td>
</tr>
<tr>
<td valign="top" align="left">Near visual acuity</td>
<td valign="top" align="center">0.615</td>
<td valign="top" align="center">0.25</td>
<td valign="top" align="center">1.849</td>
<td valign="top" align="center">0.649, 5.27</td>
</tr>
<tr>
<td valign="top" align="left">Best-corrected visual acuity</td>
<td valign="top" align="center">0.019</td>
<td valign="top" align="center">0.981</td>
<td valign="top" align="center">1.019</td>
<td valign="top" align="center">0.224, 4.638</td>
</tr>
<tr>
<td valign="top" align="left">Intraocular pressure</td>
<td valign="top" align="center">&#x2212;0.052</td>
<td valign="top" align="center">0.037</td>
<td valign="top" align="center">0.949</td>
<td valign="top" align="center">0.904, 0.997</td>
</tr>
<tr>
<td valign="top" align="left">Heart rate</td>
<td valign="top" align="center">&#x2212;0.012</td>
<td valign="top" align="center">0.025</td>
<td valign="top" align="center">0.989</td>
<td valign="top" align="center">0.979, 0.999</td>
</tr>
<tr>
<td valign="top" align="left">Blood oxygen saturation</td>
<td valign="top" align="center">&#x2212;0.02</td>
<td valign="top" align="center">0.367</td>
<td valign="top" align="center">0.98</td>
<td valign="top" align="center">0.939, 1.024</td>
</tr>
<tr>
<td valign="top" align="left">Age</td>
<td valign="top" align="center">0.106</td>
<td valign="top" align="center">0.51</td>
<td valign="top" align="center">1.111</td>
<td valign="top" align="center">0.812, 1.521</td>
</tr>
<tr>
<td valign="top" align="left" colspan="5" style="background-color: #dcdcdc;"><bold>Whether OCT was adjusted</bold></td>
</tr>
<tr>
<td valign="top" align="left">School location</td>
<td valign="top" align="center">1.055</td>
<td valign="top" align="center">&#x003C;0.001</td>
<td valign="top" align="center">2.872</td>
<td valign="top" align="center">1.616, 5.102</td>
</tr>
<tr>
<td valign="top" align="left">Heart rate</td>
<td valign="top" align="center">0.023</td>
<td valign="top" align="center">0.015</td>
<td valign="top" align="center">1.023</td>
<td valign="top" align="center">1.004, 1.042</td>
</tr>
<tr>
<td valign="top" align="left" colspan="5" style="background-color: #dcdcdc;"><bold>Optic disc</bold></td>
</tr>
<tr>
<td valign="top" align="left" colspan="5" style="background-color: #dcdcdc;"><bold>Whether OCT was completed</bold></td>
</tr>
<tr>
<td valign="top" align="left">Near visual acuity</td>
<td valign="top" align="center">1.576</td>
<td valign="top" align="center">0.009</td>
<td valign="top" align="center">4.833</td>
<td valign="top" align="center">1.491, 15.664</td>
</tr>
<tr>
<td valign="top" align="left">Heart rate</td>
<td valign="top" align="center">0.004</td>
<td valign="top" align="center">0.494</td>
<td valign="top" align="center">1.004</td>
<td valign="top" align="center">0.992, 1.017</td>
</tr>
<tr>
<td valign="top" align="left">School location</td>
<td valign="top" align="center">&#x2212;1.024</td>
<td valign="top" align="center">0.001</td>
<td valign="top" align="center">0.359</td>
<td valign="top" align="center">0.196, 0.657</td>
</tr>
<tr>
<td valign="top" align="left">Gender</td>
<td valign="top" align="center">&#x2212;0.367</td>
<td valign="top" align="center">0.037</td>
<td valign="top" align="center">0.693</td>
<td valign="top" align="center">0.491, 0.978</td>
</tr>
<tr>
<td valign="top" align="left">Amblyopia</td>
<td valign="top" align="center">&#x2212;0.419</td>
<td valign="top" align="center">0.56</td>
<td valign="top" align="center">0.658</td>
<td valign="top" align="center">0.161, 2.691</td>
</tr>
<tr>
<td valign="top" align="left">Visual acuity</td>
<td valign="top" align="center">0.197</td>
<td valign="top" align="center">0.746</td>
<td valign="top" align="center">1.218</td>
<td valign="top" align="center">0.37, 4.002</td>
</tr>
<tr>
<td valign="top" align="left">Height</td>
<td valign="top" align="center">0.001</td>
<td valign="top" align="center">0.966</td>
<td valign="top" align="center">1.001</td>
<td valign="top" align="center">0.959, 1.045</td>
</tr>
<tr>
<td valign="top" align="left">Weight</td>
<td valign="top" align="center">&#x2212;0.053</td>
<td valign="top" align="center">0.124</td>
<td valign="top" align="center">0.949</td>
<td valign="top" align="center">0.887, 1.015</td>
</tr>
<tr>
<td valign="top" align="left">Best-corrected visual acuity</td>
<td valign="top" align="center">1.964</td>
<td valign="top" align="center">0.107</td>
<td valign="top" align="center">7.126</td>
<td valign="top" align="center">0.656, 77.38</td>
</tr>
<tr>
<td valign="top" align="left" colspan="5" style="background-color: #dcdcdc;"><bold>Whether OCT was deleted</bold></td>
</tr>
<tr>
<td valign="top" align="left">Near visual acuity</td>
<td valign="top" align="center">1.893</td>
<td valign="top" align="center">&#x003C;0.001</td>
<td valign="top" align="center">6.64</td>
<td valign="top" align="center">2.832, 15.57</td>
</tr>
<tr>
<td valign="top" align="left">Heart rate</td>
<td valign="top" align="center">0.001</td>
<td valign="top" align="center">0.774</td>
<td valign="top" align="center">1.001</td>
<td valign="top" align="center">0.993, 1.01</td>
</tr>
<tr>
<td valign="top" align="left">School location</td>
<td valign="top" align="center">0.554</td>
<td valign="top" align="center">&#x003C;0.001</td>
<td valign="top" align="center">1.741</td>
<td valign="top" align="center">1.323, 2.29</td>
</tr>
<tr>
<td valign="top" align="left">Gender</td>
<td valign="top" align="center">&#x2212;0.248</td>
<td valign="top" align="center">0.033</td>
<td valign="top" align="center">0.78</td>
<td valign="top" align="center">0.621, 0.98</td>
</tr>
<tr>
<td valign="top" align="left">Ethnicity</td>
<td valign="top" align="center">&#x2212;0.497</td>
<td valign="top" align="center">0.141</td>
<td valign="top" align="center">0.608</td>
<td valign="top" align="center">0.314, 1.178</td>
</tr>
<tr>
<td valign="top" align="left" colspan="5" style="background-color: #dcdcdc;"><bold>Whether OCT was adjusted</bold></td>
</tr>
<tr>
<td valign="top" align="left">Near visual acuity</td>
<td valign="top" align="center">2.664</td>
<td valign="top" align="center">&#x003C;0.001</td>
<td valign="top" align="center">14.353</td>
<td valign="top" align="center">5.431, 37.933</td>
</tr>
<tr>
<td valign="top" align="left">Intraocular pressure</td>
<td valign="top" align="center">&#x2212;0.041</td>
<td valign="top" align="center">0.057</td>
<td valign="top" align="center">0.96</td>
<td valign="top" align="center">0.921, 1.001</td>
</tr>
<tr>
<td valign="top" align="left">BMI</td>
<td valign="top" align="center">&#x2212;0.071</td>
<td valign="top" align="center">0.028</td>
<td valign="top" align="center">0.932</td>
<td valign="top" align="center">0.875, 0.992</td>
</tr>
<tr>
<td valign="top" align="left">Heart rate</td>
<td valign="top" align="center">0.004</td>
<td valign="top" align="center">0.422</td>
<td valign="top" align="center">1.004</td>
<td valign="top" align="center">0.995, 1.012</td>
</tr>
<tr>
<td valign="top" align="left">Age</td>
<td valign="top" align="center">0.11</td>
<td valign="top" align="center">0.432</td>
<td valign="top" align="center">1.116</td>
<td valign="top" align="center">0.849, 1.466</td>
</tr>
<tr>
<td valign="top" align="left">School location</td>
<td valign="top" align="center">1.148</td>
<td valign="top" align="center">&#x003C;0.001</td>
<td valign="top" align="center">3.153</td>
<td valign="top" align="center">2.183, 4.554</td>
</tr>
</tbody>
</table></table-wrap>
</sec>
<sec id="S3.SS5">
<title>Correlation analysis after manual segmentation of images</title>
<p>Except for the images that were directly deleted due to poor quality, some of the images had deviations in position or range alignment, so we restored the proper position of these scans by manual segmentation and compared the image parameters before and after the changes. A significantly higher percentage of 51.4% images in the optic disc area require manual segmentation compared to the macula (4.6%). The OCT scans of suburban students requires more manual segmentation in both the macula and optic disc regions than students in urban schools. Scans of the optic disc area showed that students requiring image adjustments had significantly worse near vision (<italic>t</italic> = 6.84, <italic>P</italic> &#x003C; 0.001), lower IOP (<italic>t</italic> = &#x2212;2.19, <italic>P</italic> = 0.03), BMI (<italic>t</italic> = &#x2212;2.44, <italic>P</italic> = 0.02) and heart rate (<italic>t</italic> = &#x2212;3.02, <italic>P</italic> = 0.003) and were older (<italic>t</italic> = 4.09, <italic>P</italic> &#x003C; 0.001) (<xref ref-type="supplementary-material" rid="TS1">Supplementary Table 1</xref>). The results of the multivariate logistic regression analysis in the optic disc area were consistent with the above. No other significant differences were found in the macular area scans (<xref ref-type="table" rid="T3">Table 3</xref>).</p>
<p>Using the values obtained by automatic machine segmentation and measurement, we compared the retinal thickness and optic disc related parameters in each region of the macula and optic disc before and after manual segmentation. We found that adjusted retinal thickness in the macula varied only within a few ETDRS subregions, but there were no significant changes in mean retinal thickness and volume across the region. In contrast, after manual segmentation, significant differences were observed in almost all subregions of the optic disc area, both under 4 and 12 subregions mode (<xref ref-type="fig" rid="F3">Figure 3</xref>). The retinal thickness in most subregions tended to increase after adjustment (<xref ref-type="table" rid="T4">Table 4</xref>).</p>
<fig id="F3" position="float">
<label>FIGURE 3</label>
<caption><p>Circumpapillary retinal nerve fiber layer thickness in 4 and 12 subregions before and after the manual segmentation.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmed-12-1495527-g003.tif"/>
</fig>
<table-wrap position="float" id="T4">
<label>TABLE 4</label>
<caption><p>Paired <italic>t</italic>-test of OCT measurements before and after manual segmentation.</p></caption>
<table cellspacing="5" cellpadding="5" frame="box" rules="all">
<thead>
<tr>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;"></td>
<td valign="top" align="center" style="color:#ffffff;background-color: #7f8080;">Mean</td>
<td valign="top" align="center" style="color:#ffffff;background-color: #7f8080;">SD</td>
<td valign="top" align="center" style="color:#ffffff;background-color: #7f8080;"><italic>t</italic></td>
<td valign="top" align="center" style="color:#ffffff;background-color: #7f8080;"><italic>P</italic>-value</td>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left" colspan="5" style="background-color: #dcdcdc;"><bold>Macula</bold></td>
</tr>
<tr>
<td valign="top" align="left">Average</td>
<td valign="top" align="center">&#x2212;0.03</td>
<td valign="top" align="center">1.22</td>
<td valign="top" align="center">&#x2212;0.87</td>
<td valign="top" align="center">0.387</td>
</tr>
<tr>
<td valign="top" align="left">Foveal minimum</td>
<td valign="top" align="center">0.38</td>
<td valign="top" align="center">9.69</td>
<td valign="top" align="center">1.49</td>
<td valign="top" align="center">0.137</td>
</tr>
<tr>
<td valign="top" align="left">Center</td>
<td valign="top" align="center">0.39</td>
<td valign="top" align="center">6.70</td>
<td valign="top" align="center">2.21</td>
<td valign="top" align="center">0.028</td>
</tr>
<tr>
<td valign="top" align="left">Inner temporal</td>
<td valign="top" align="center">&#x2212;0.08</td>
<td valign="top" align="center">5.09</td>
<td valign="top" align="center">&#x2212;0.61</td>
<td valign="top" align="center">0.542</td>
</tr>
<tr>
<td valign="top" align="left">Inner superior</td>
<td valign="top" align="center">&#x2212;0.10</td>
<td valign="top" align="center">1.91</td>
<td valign="top" align="center">&#x2212;2.05</td>
<td valign="top" align="center">0.041</td>
</tr>
<tr>
<td valign="top" align="left">Inner nasal</td>
<td valign="top" align="center">&#x2212;0.19</td>
<td valign="top" align="center">2.41</td>
<td valign="top" align="center">&#x2212;3.02</td>
<td valign="top" align="center">0.003</td>
</tr>
<tr>
<td valign="top" align="left">Inner inferior</td>
<td valign="top" align="center">&#x2212;0.13</td>
<td valign="top" align="center">2.25</td>
<td valign="top" align="center">&#x2212;2.23</td>
<td valign="top" align="center">0.026</td>
</tr>
<tr>
<td valign="top" align="left">Outer temporal</td>
<td valign="top" align="center">0.00</td>
<td valign="top" align="center">2.54</td>
<td valign="top" align="center">&#x2212;0.04</td>
<td valign="top" align="center">0.966</td>
</tr>
<tr>
<td valign="top" align="left">Outer superior</td>
<td valign="top" align="center">&#x2212;0.12</td>
<td valign="top" align="center">1.80</td>
<td valign="top" align="center">&#x2212;2.44</td>
<td valign="top" align="center">0.015</td>
</tr>
<tr>
<td valign="top" align="left">Outer nasal</td>
<td valign="top" align="center">&#x2212;0.02</td>
<td valign="top" align="center">1.39</td>
<td valign="top" align="center">&#x2212;0.59</td>
<td valign="top" align="center">0.555</td>
</tr>
<tr>
<td valign="top" align="left">Outer inferior</td>
<td valign="top" align="center">0.08</td>
<td valign="top" align="center">2.16</td>
<td valign="top" align="center">1.39</td>
<td valign="top" align="center">0.166</td>
</tr>
<tr>
<td valign="top" align="left">Total volume (mm<sup>3</sup>)</td>
<td valign="top" align="center">0.00</td>
<td valign="top" align="center">0.03</td>
<td valign="top" align="center">&#x2212;0.92</td>
<td valign="top" align="center">0.358</td>
</tr>
<tr>
<td valign="top" align="left" colspan="5" style="background-color: #dcdcdc;"><bold>Optic disc</bold></td>
</tr>
<tr>
<td valign="top" align="left">Global average</td>
<td valign="top" align="center">&#x2212;1.89</td>
<td valign="top" align="center">10.73</td>
<td valign="top" align="center">&#x2212;6.34</td>
<td valign="top" align="center">&#x003C;0.001</td>
</tr>
<tr>
<td valign="top" align="left">Temporal</td>
<td valign="top" align="center">&#x2212;1.85</td>
<td valign="top" align="center">10.31</td>
<td valign="top" align="center">&#x2212;6.45</td>
<td valign="top" align="center">&#x003C;0.001</td>
</tr>
<tr>
<td valign="top" align="left">Superior</td>
<td valign="top" align="center">&#x2212;2.62</td>
<td valign="top" align="center">16.25</td>
<td valign="top" align="center">&#x2212;5.78</td>
<td valign="top" align="center">&#x003C;0.001</td>
</tr>
<tr>
<td valign="top" align="left">Nasal</td>
<td valign="top" align="center">0.61</td>
<td valign="top" align="center">8.81</td>
<td valign="top" align="center">2.48</td>
<td valign="top" align="center">0.013</td>
</tr>
<tr>
<td valign="top" align="left">Inferior</td>
<td valign="top" align="center">&#x2212;3.66</td>
<td valign="top" align="center">18.00</td>
<td valign="top" align="center">&#x2212;7.29</td>
<td valign="top" align="center">&#x003C;0.001</td>
</tr>
<tr>
<td valign="top" align="left">9 o&#x2019;clock</td>
<td valign="top" align="center">&#x2212;1.38</td>
<td valign="top" align="center">8.81</td>
<td valign="top" align="center">&#x2212;5.64</td>
<td valign="top" align="center">&#x003C;0.001</td>
</tr>
<tr>
<td valign="top" align="left">10 o&#x2019;clock</td>
<td valign="top" align="center">&#x2212;2.36</td>
<td valign="top" align="center">12.55</td>
<td valign="top" align="center">&#x2212;6.76</td>
<td valign="top" align="center">&#x003C;0.001</td>
</tr>
<tr>
<td valign="top" align="left">11 o&#x2019;clock</td>
<td valign="top" align="center">&#x2212;4.22</td>
<td valign="top" align="center">19.50</td>
<td valign="top" align="center">&#x2212;7.76</td>
<td valign="top" align="center">&#x003C;0.001</td>
</tr>
<tr>
<td valign="top" align="left">12 o&#x2019;clock</td>
<td valign="top" align="center">&#x2212;2.65</td>
<td valign="top" align="center">20.48</td>
<td valign="top" align="center">&#x2212;4.64</td>
<td valign="top" align="center">&#x003C;0.001</td>
</tr>
<tr>
<td valign="top" align="left">1 o&#x2019;clock</td>
<td valign="top" align="center">&#x2212;1.00</td>
<td valign="top" align="center">13.76</td>
<td valign="top" align="center">&#x2212;2.60</td>
<td valign="top" align="center">0.009</td>
</tr>
<tr>
<td valign="top" align="left">2 o&#x2019;clock</td>
<td valign="top" align="center">0.40</td>
<td valign="top" align="center">11.38</td>
<td valign="top" align="center">1.25</td>
<td valign="top" align="center">0.211</td>
</tr>
<tr>
<td valign="top" align="left">3 o&#x2019;clock</td>
<td valign="top" align="center">0.65</td>
<td valign="top" align="center">8.69</td>
<td valign="top" align="center">2.67</td>
<td valign="top" align="center">0.008</td>
</tr>
<tr>
<td valign="top" align="left">4 o&#x2019;clock</td>
<td valign="top" align="center">0.78</td>
<td valign="top" align="center">10.07</td>
<td valign="top" align="center">2.79</td>
<td valign="top" align="center">0.005</td>
</tr>
<tr>
<td valign="top" align="left">5 o&#x2019;clock</td>
<td valign="top" align="center">&#x2212;1.89</td>
<td valign="top" align="center">14.61</td>
<td valign="top" align="center">&#x2212;4.65</td>
<td valign="top" align="center">&#x003C;0.001</td>
</tr>
<tr>
<td valign="top" align="left">6 o&#x2019;clock</td>
<td valign="top" align="center">&#x2212;4.39</td>
<td valign="top" align="center">23.42</td>
<td valign="top" align="center">&#x2212;6.73</td>
<td valign="top" align="center">&#x003C;0.001</td>
</tr>
<tr>
<td valign="top" align="left">7 o&#x2019;clock</td>
<td valign="top" align="center">&#x2212;4.60</td>
<td valign="top" align="center">20.74</td>
<td valign="top" align="center">&#x2212;7.97</td>
<td valign="top" align="center">&#x003C;0.001</td>
</tr>
<tr>
<td valign="top" align="left">8 o&#x2019;clock</td>
<td valign="top" align="center">&#x2212;1.79</td>
<td valign="top" align="center">11.80</td>
<td valign="top" align="center">&#x2212;5.46</td>
<td valign="top" align="center">&#x003C;0.001</td>
</tr>
</tbody>
</table></table-wrap>
</sec>
</sec>
<sec id="S4" sec-type="discussion">
<title>Discussion</title>
<p>Focusing on a large cohort of minority children, this study shed light on the clinical findings of subjects characteristics and image quality related factors in Tibetan children by OCT. In this study, we used manual segmentation to correct errors in automated macular and optic-disc segmentation to better reflect the anatomy represented in each scan. This study found that: (1) high analyzable fraction (91.5%) after exclusion of incomplete protocols or examination procedures; (2) the most significant causes of image failure are image defects and shifts caused by blinking and poor fixation stability in children; (3) multivariate analysis identified suburban residence, lower near VA, and male gender as significant predictors of worse image quality; and (4) differences in retinal thickness and optic disc parameters were observed pre and post-adjustment, with more significant changes in the optic disc area.</p>
<p>This study found that the response rate and coordination of Tibetan children for completing the OCT examination were relatively higher compared to other previous studies. In the Anyang Childhood Eye Study, about 7% of children aged 12 years old had failed images (<xref ref-type="bibr" rid="B18">18</xref>). In the Sydney Childhood Eye Study, OCT scans failed in about 21% of children aged 6 years (<xref ref-type="bibr" rid="B19">19</xref>). Although our study was conducted among Tibetan children and most 7-year-old Tibetan children are still unable to use Chinese to communicate, we still obtained a pass rate of nearly 85% of the scanned macular area. While this attrition rate is relatively low, it underscores the challenges inherent in longitudinal studies involving young children. Previous studies of screening with the Topcon device have shown an ineligible rate of about 20% and a scan rejection rate of about 2%&#x2013;5% (<xref ref-type="bibr" rid="B16">16</xref>). Also the optic disc has a higher rejection rate than the macula. The primary reasons for image exclusion included defects related to blinking or poor fixation stability, image blurring, and uncorrectable positioning errors. This highlights the importance of rigorous quality control measures in ensuring reliable data acquisition.</p>
<p>In our investigation, a noteworthy correlation emerged between children&#x2019;s near VA and the quality of OCT scans. Notably, children with superior near VA exhibited higher OCT imaging quality. Healthy children typically demonstrate enhanced ocular accommodation, and the majority of subjects in our study boasted near VA within the normal range. This phenomenon might be attributed to the proximity of internal optic markers of OCT to the eye, whereby myopic acuity can influence children&#x2019;s fixation on these markers, thereby affecting the speed and quality of OCT scans. Previous research often links fixation stability with anisometropia, high myopia, strabismus, and amblyopia, yet the association with near vision remains largely unexplored (<xref ref-type="bibr" rid="B20">20</xref>, <xref ref-type="bibr" rid="B21">21</xref>). Our study&#x2019;s distribution of near visual acuity largely fell within the normal range compared to past studies, suggesting that a child&#x2019;s near vision may exert a substantial influence on the quality of OCT examinations, particularly when the fixation optic marker is situated nearby (<xref ref-type="bibr" rid="B22">22</xref>, <xref ref-type="bibr" rid="B23">23</xref>). Despite the absence of standardized clinical guidelines for near visual acuity measurement, its significance in determining the rehabilitation of visually impaired children cannot be overstated, underscoring the necessity for further exploration of the association between fixation stability and near visual acuity.</p>
<p>Furthermore, our findings reveal a significant association between the quality of OCT scans and the educational locale and gender of the children. Notably, girls demonstrated significantly higher proficiency in completing OCT scans with qualified images compared to boys, aligning with common perceptions that boys tend to exhibit more rambunctious behavior and are less inclined to cooperate during examinations. Moreover, our study observed that children attending schools in suburban areas underwent more OCT scans necessitating deletion and adjustment. Interestingly, despite exhibiting greater discipline during examinations, children from suburban schools often face language barriers due to their lower proficiency in Chinese, potentially hindering their performance in examinations. This study also revealed that lower image quality is associated with higher intraocular pressure and heart rate. Non-contact tonometry, due to its air-puff mechanism, often yields elevated intraocular pressure readings in children, as blinking or eyelash obstruction commonly interferes with measurements. Similarly, higher heart rates may be linked to the heightened activity levels typical of children. Therefore, increased intraocular pressure and heart rate may indicate that children are more active, sensitive, and less cooperative during examinations, ultimately resulting in reduced image quality.</p>
<p>Recent research underscores the reproducibility and clinical utility of OCT in pediatric populations (<xref ref-type="bibr" rid="B24">24</xref>&#x2013;<xref ref-type="bibr" rid="B26">26</xref>). Our study reveals that OCT examinations conducted post-dilation in school-age children, coupled with the software&#x2019;s automated segmentation calculations, yield informative results. However, automatic positioning segmentation errors contribute to thinner measured retinal thicknesses, consistent with prior investigations (<xref ref-type="bibr" rid="B27">27</xref>&#x2013;<xref ref-type="bibr" rid="B29">29</xref>). Literature suggests that erroneous positioning of the optic disc or macular region by OCT often leads to deviations from normal values (<xref ref-type="bibr" rid="B30">30</xref>, <xref ref-type="bibr" rid="B31">31</xref>). Topcon&#x2019;s normal population database highlights the necessity for manual adjustments to rectify automatic segmentation errors, including grid locations, boundary segmentations, and disc margins with Fastmap, executed by clinical experts (<xref ref-type="bibr" rid="B16">16</xref>). Such errors may stem from inherent flaws in the machine algorithm. By manually repositioning the measurement region to its correct anatomical location, more accurate measurement values can typically be obtained. Our study also underscores that in the absence of obvious artifacts or image loss, most images can yield relatively valid measurement values through proper repositioning of the measurement area. This underscores the importance of manual supervision and adjustment in epidemiological screening or clinical practice to ensure the accuracy and authenticity of OCT scan results.</p>
<p>This study possesses several strengths as well as limitations. On one hand, the sample size is considerable, the examination protocols are comprehensive, the dataset is comprehensive, and the sample demographics are robust, particularly targeting minority children. However, the investigation solely examined the overall retinal thickness in the macular and optic disc regions, without delving into the perfection of OCT&#x2019;s layered functionality. Furthermore, there exists a degree of subjectivity in the manual segmentation process of OCT scans. Additionally, the study predominantly included healthy children, warranting further exploration of OCT scanning outcomes in diverse retinal pathologies.</p>
</sec>
<sec id="S5" sec-type="conclusion">
<title>Conclusion</title>
<p>In conclusion, completion rates of OCT examinations for large-scale pediatric eye screening can reach high levels, and their completion rates are related to educational location, gender, visual acuity, and amblyopia; worse near vision significantly affects OCT image quality and completion rate; OCT scans in pediatric subjects pose greater challenges for alignment in the optic disc area compared to the macular region, and retinal thickness in both regions tends to be thinner than normal in the automated segmentation computations of the OCT apparatus. These discoveries enrich our comprehension of the factors influencing image quality in pediatric OCT imaging and underscore the imperative of rigorous quality assurance measures in large-scale epidemiological investigations.</p>
</sec>
</body>
<back>
<sec id="S6" sec-type="data-availability">
<title>Data availability statement</title>
<p>The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.</p>
</sec>
<sec id="S7" sec-type="ethics-statement">
<title>Ethics statement</title>
<p>The studies involving humans were approved by the Ethics Committee of the Beijing Tongren Hospital, Capital Medical University (No. TRECKY2019-058). The studies were conducted in accordance with the local legislation and institutional requirements. Written informed consent for participation in this study was provided by the participants&#x2019; legal guardians/next of kin.</p>
</sec>
<sec id="S8" sec-type="author-contributions">
<title>Author contributions</title>
<p>YY: Data curation, Formal analysis, Writing &#x2013; original draft. JL: Writing &#x2013; review &#x0026; editing. LL: Formal analysis, Methodology, Writing &#x2013; review &#x0026; editing. WC: Data curation, Methodology, Project administration, Writing &#x2013; review &#x0026; editing. ZM: Data curation, Formal analysis, Project administration, Writing &#x2013; review &#x0026; editing. JF: Conceptualization, Funding acquisition, Project administration, Supervision, Writing &#x2013; original draft.</p>
</sec>
<sec id="S9" sec-type="funding-information">
<title>Funding</title>
<p>The author(s) declare financial support was received for the research, authorship, and/or publication of this article. Supported by National Natural Science Foundation of China (Grant No. 82070998), Capital Research Project of Clinical Diagnosis and Treatment Technology and Translational Application, Beijing Municipal Science and Technology Commission (Z201100005520044).</p>
</sec>
<ack><p>The authors thank the staff and participants in the Lhasa Childhood Eye Study for their help and support.</p>
</ack>
<sec id="S10" sec-type="COI-statement">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec id="S11" sec-type="disclaimer">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<sec id="S12" sec-type="supplementary-material">
<title>Supplementary material</title>
<p>The Supplementary Material for this article can be found online at: <ext-link ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/fmed.2025.1495527/full#supplementary-material">https://www.frontiersin.org/articles/10.3389/fmed.2025.1495527/full#supplementary-material</ext-link></p>
<supplementary-material xlink:href="Table_1.docx" id="TS1" mimetype="application/vnd.openxmlformats-officedocument.wordprocessingml.document" xmlns:xlink="http://www.w3.org/1999/xlink"></supplementary-material>
</sec>
<ref-list>
<title>References</title>
<ref id="B1"><label>1.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Drexler</surname> <given-names>W</given-names></name> <name><surname>Fujimoto</surname> <given-names>J</given-names></name></person-group>. <article-title>State-of-the-art retinal optical coherence tomography.</article-title> <source><italic>Prog Retin Eye Res.</italic></source> (<year>2008</year>) <volume>27</volume>(<issue>1</issue>):<fpage>45</fpage>&#x2013;<lpage>88</lpage>. <pub-id pub-id-type="doi">10.1016/j.preteyeres.2007.07.005</pub-id> <pub-id pub-id-type="pmid">18036865</pub-id></citation></ref>
<ref id="B2"><label>2.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fercher</surname> <given-names>A</given-names></name></person-group>. <article-title>Optical coherence tomography - development, principles, applications.</article-title> <source><italic>Z Med Phys.</italic></source> (<year>2010</year>) <volume>20</volume>(<issue>4</issue>):<fpage>251</fpage>&#x2013;<lpage>76</lpage>. <pub-id pub-id-type="doi">10.1016/j.zemedi.2009.11.002</pub-id> <pub-id pub-id-type="pmid">21134630</pub-id></citation></ref>
<ref id="B3"><label>3.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Huang</surname> <given-names>D</given-names></name> <name><surname>Swanson</surname> <given-names>E</given-names></name> <name><surname>Lin</surname> <given-names>C</given-names></name> <name><surname>Schuman</surname> <given-names>J</given-names></name> <name><surname>Stinson</surname> <given-names>W</given-names></name> <name><surname>Chang</surname> <given-names>W</given-names></name><etal/></person-group> <article-title>Optical coherence tomography.</article-title> <source><italic>Science.</italic></source> (<year>1991</year>) <volume>254</volume>(<issue>5035</issue>):<fpage>1178</fpage>&#x2013;<lpage>81</lpage>. <pub-id pub-id-type="doi">10.1126/science.1957169</pub-id> <pub-id pub-id-type="pmid">1957169</pub-id></citation></ref>
<ref id="B4"><label>4.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hrynchak</surname> <given-names>P</given-names></name> <name><surname>Simpson</surname> <given-names>T</given-names></name></person-group>. <article-title>Optical coherence tomography: An introduction to the technique and its use.</article-title> <source><italic>Optom Vis Sci.</italic></source> (<year>2000</year>) <volume>77</volume>(<issue>7</issue>):<fpage>347</fpage>&#x2013;<lpage>56</lpage>. <pub-id pub-id-type="doi">10.1097/00006324-200007000-00009</pub-id> <pub-id pub-id-type="pmid">10939312</pub-id></citation></ref>
<ref id="B5"><label>5.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Thomas</surname> <given-names>D</given-names></name> <name><surname>Duguid</surname> <given-names>G</given-names></name></person-group>. <article-title>Optical coherence tomography&#x2013;a review of the principles and contemporary uses in retinal investigation.</article-title> <source><italic>Eye.</italic></source> (<year>2004</year>) <volume>18</volume>(<issue>6</issue>):<fpage>561</fpage>&#x2013;<lpage>70</lpage>. <pub-id pub-id-type="doi">10.1038/sj.eye.6700729</pub-id> <pub-id pub-id-type="pmid">14765099</pub-id></citation></ref>
<ref id="B6"><label>6.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Drexler</surname> <given-names>W</given-names></name> <name><surname>Sattmann</surname> <given-names>H</given-names></name> <name><surname>Hermann</surname> <given-names>B</given-names></name> <name><surname>Ko</surname> <given-names>T</given-names></name> <name><surname>Stur</surname> <given-names>M</given-names></name> <name><surname>Unterhuber</surname> <given-names>A</given-names></name><etal/></person-group> <article-title>Enhanced visualization of macular pathology with the use of ultrahigh-resolution optical coherence tomography.</article-title> <source><italic>Arch Ophthalmol.</italic></source> (<year>2003</year>) <volume>121</volume>(<issue>5</issue>):<fpage>695</fpage>&#x2013;<lpage>706</lpage>. <pub-id pub-id-type="doi">10.1001/archopht.121.5.695</pub-id> <pub-id pub-id-type="pmid">12742848</pub-id></citation></ref>
<ref id="B7"><label>7.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Drexler</surname> <given-names>W</given-names></name></person-group>. <article-title>Ultrahigh-resolution optical coherence tomography.</article-title> <source><italic>J Biomed Opt.</italic></source> (<year>2004</year>) <volume>9</volume>(<issue>1</issue>):<fpage>47</fpage>&#x2013;<lpage>74</lpage>. <pub-id pub-id-type="doi">10.1117/1.1629679</pub-id> <pub-id pub-id-type="pmid">14715057</pub-id></citation></ref>
<ref id="B8"><label>8.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yao</surname> <given-names>Y</given-names></name> <name><surname>Fu</surname> <given-names>J</given-names></name> <name><surname>Li</surname> <given-names>L</given-names></name> <name><surname>Chen</surname> <given-names>W</given-names></name> <name><surname>Meng</surname> <given-names>Z</given-names></name> <name><surname>Su</surname> <given-names>H</given-names></name><etal/></person-group> <article-title>Retinal and circumpapillary nerve fiber layer thickness and associated factors in children.</article-title> <source><italic>Eye.</italic></source> (<year>2021</year>) <volume>35</volume>(<issue>10</issue>):<fpage>2802</fpage>&#x2013;<lpage>11</lpage>. <pub-id pub-id-type="doi">10.1038/s41433-020-01313-z</pub-id> <pub-id pub-id-type="pmid">33239762</pub-id></citation></ref>
<ref id="B9"><label>9.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Duan</surname> <given-names>X</given-names></name> <name><surname>Liang</surname> <given-names>Y</given-names></name> <name><surname>Friedman</surname> <given-names>D</given-names></name> <name><surname>Sun</surname> <given-names>L</given-names></name> <name><surname>Wong</surname> <given-names>T</given-names></name> <name><surname>Tao</surname> <given-names>Q</given-names></name><etal/></person-group> <article-title>Normal macular thickness measurements using optical coherence tomography in healthy eyes of adult chinese persons: The handan eye study.</article-title> <source><italic>Ophthalmology.</italic></source> (<year>2010</year>) <volume>117</volume>(<issue>8</issue>):<fpage>1585</fpage>&#x2013;<lpage>94</lpage>. <pub-id pub-id-type="doi">10.1016/j.ophtha.2009.12.036</pub-id> <pub-id pub-id-type="pmid">20472290</pub-id></citation></ref>
<ref id="B10"><label>10.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tham</surname> <given-names>Y</given-names></name> <name><surname>Chee</surname> <given-names>M</given-names></name> <name><surname>Dai</surname> <given-names>W</given-names></name> <name><surname>Lim</surname> <given-names>Z</given-names></name> <name><surname>Majithia</surname> <given-names>S</given-names></name> <name><surname>Siantar</surname> <given-names>R</given-names></name><etal/></person-group> <article-title>Profiles of ganglion cell-inner plexiform layer thickness in a multi-ethnic asian population: The singapore epidemiology of eye diseases study.</article-title> <source><italic>Ophthalmology.</italic></source> (<year>2020</year>) <volume>127</volume>(<issue>8</issue>):<fpage>1064</fpage>&#x2013;<lpage>76</lpage>. <pub-id pub-id-type="doi">10.1016/j.ophtha.2020.01.055</pub-id> <pub-id pub-id-type="pmid">32197910</pub-id></citation></ref>
<ref id="B11"><label>11.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Alasil</surname> <given-names>T</given-names></name> <name><surname>Keane</surname> <given-names>P</given-names></name> <name><surname>Sim</surname> <given-names>D</given-names></name> <name><surname>Tufail</surname> <given-names>A</given-names></name> <name><surname>Rauser</surname> <given-names>M</given-names></name></person-group>. <article-title>Optical coherence tomography in pediatric ophthalmology: Current roles and future directions.</article-title> <source><italic>Ophthalmic Surg Lasers Imaging Retina.</italic></source> (<year>2013</year>) <volume>44</volume>(<issue>6 Suppl</issue>):<fpage>S19</fpage>&#x2013;<lpage>29</lpage>. <pub-id pub-id-type="doi">10.3928/23258160-20131101-04</pub-id> <pub-id pub-id-type="pmid">24220880</pub-id></citation></ref>
<ref id="B12"><label>12.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tan</surname> <given-names>C</given-names></name> <name><surname>Chan</surname> <given-names>J</given-names></name> <name><surname>Cheong</surname> <given-names>K</given-names></name> <name><surname>Ngo</surname> <given-names>W</given-names></name> <name><surname>Sadda</surname> <given-names>S</given-names></name></person-group>. <article-title>Comparison of retinal thicknesses measured using swept-source and spectral-domain optical coherence tomography devices.</article-title> <source><italic>Ophthalmic Surg Lasers Imaging Retina.</italic></source> (<year>2015</year>) <volume>46</volume>(<issue>2</issue>):<fpage>172</fpage>&#x2013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.3928/23258160-20150213-23</pub-id> <pub-id pub-id-type="pmid">25707041</pub-id></citation></ref>
<ref id="B13"><label>13.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Maccora</surname> <given-names>K</given-names></name> <name><surname>Sheth</surname> <given-names>S</given-names></name> <name><surname>Ruddle</surname> <given-names>J</given-names></name></person-group>. <article-title>Optical coherence tomography in paediatric clinical practice.</article-title> <source><italic>Clin Exp Optom.</italic></source> (<year>2019</year>) <volume>102</volume>(<issue>3</issue>):<fpage>300</fpage>&#x2013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1111/cxo.12909</pub-id> <pub-id pub-id-type="pmid">30983019</pub-id></citation></ref>
<ref id="B14"><label>14.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chen</surname> <given-names>W</given-names></name> <name><surname>Fu</surname> <given-names>J</given-names></name> <name><surname>Meng</surname> <given-names>Z</given-names></name> <name><surname>Li</surname> <given-names>L</given-names></name> <name><surname>Su</surname> <given-names>H</given-names></name> <name><surname>Dai</surname> <given-names>W</given-names></name><etal/></person-group> <article-title>Lhasa childhood eye study: The rationale, methodology, and baseline data of a 5 year follow-up of school-based cohort study in the tibetan plateau region of southwest china.</article-title> <source><italic>BMC Ophthalmol.</italic></source> (<year>2020</year>) <volume>20</volume>(<issue>1</issue>):<fpage>250</fpage>. <pub-id pub-id-type="doi">10.1186/s12886-020-01522-w</pub-id> <pub-id pub-id-type="pmid">32571250</pub-id></citation></ref>
<ref id="B15"><label>15.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tewarie</surname> <given-names>P</given-names></name> <name><surname>Balk</surname> <given-names>L</given-names></name> <name><surname>Costello</surname> <given-names>F</given-names></name> <name><surname>Green</surname> <given-names>A</given-names></name> <name><surname>Martin</surname> <given-names>R</given-names></name> <name><surname>Schippling</surname> <given-names>S</given-names></name><etal/></person-group> <article-title>The oscar-ib consensus criteria for retinal oct quality assessment.</article-title> <source><italic>PLoS One.</italic></source> (<year>2012</year>) <volume>7</volume>(<issue>4</issue>):<fpage>e34823</fpage>. <pub-id pub-id-type="doi">10.1371/journal.pone.0034823</pub-id> <pub-id pub-id-type="pmid">22536333</pub-id></citation></ref>
<ref id="B16"><label>16.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chaglasian</surname> <given-names>M</given-names></name> <name><surname>Fingeret</surname> <given-names>M</given-names></name> <name><surname>Davey</surname> <given-names>P</given-names></name> <name><surname>Huang</surname> <given-names>W</given-names></name> <name><surname>Leung</surname> <given-names>D</given-names></name> <name><surname>Ng</surname> <given-names>E</given-names></name><etal/></person-group> <article-title>The development of a reference database with the topcon 3d oct-1 maestro.</article-title> <source><italic>Clin Ophthalmol.</italic></source> (<year>2018</year>) <volume>12</volume>:<fpage>849</fpage>&#x2013;<lpage>57</lpage>. <pub-id pub-id-type="doi">10.2147/OPTH.S155229</pub-id> <pub-id pub-id-type="pmid">29765199</pub-id></citation></ref>
<ref id="B17"><label>17.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Holmstr&#x00F6;m</surname> <given-names>G</given-names></name> <name><surname>Eriksson</surname> <given-names>U</given-names></name> <name><surname>Hellgren</surname> <given-names>K</given-names></name> <name><surname>Larsson</surname> <given-names>E</given-names></name></person-group>. <article-title>Optical coherence tomography is helpful in the diagnosis of foveal hypoplasia.</article-title> <source><italic>Acta Ophthalmol.</italic></source> (<year>2010</year>) <volume>88</volume>(<issue>4</issue>):<fpage>439</fpage>&#x2013;<lpage>42</lpage>. <pub-id pub-id-type="doi">10.1111/j.1755-3768.2009.01533.x</pub-id> <pub-id pub-id-type="pmid">19493249</pub-id></citation></ref>
<ref id="B18"><label>18.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhu</surname> <given-names>B</given-names></name> <name><surname>Li</surname> <given-names>S</given-names></name> <name><surname>Li</surname> <given-names>H</given-names></name> <name><surname>Liu</surname> <given-names>L</given-names></name> <name><surname>Wang</surname> <given-names>Y</given-names></name> <name><surname>Yang</surname> <given-names>Z</given-names></name><etal/></person-group> <article-title>Retinal nerve fiber layer thickness in a population of 12-year-old children in central china measured by ivue-100 spectral-domain optical coherence tomography: The anyang childhood eye study.</article-title> <source><italic>Invest Ophthalmol Vis Sci.</italic></source> (<year>2013</year>) <volume>54</volume>(<issue>13</issue>):<fpage>8104</fpage>&#x2013;<lpage>11</lpage>. <pub-id pub-id-type="doi">10.1167/iovs.13-11958</pub-id> <pub-id pub-id-type="pmid">24150754</pub-id></citation></ref>
<ref id="B19"><label>19.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Huynh</surname> <given-names>S</given-names></name> <name><surname>Wang</surname> <given-names>X</given-names></name> <name><surname>Rochtchina</surname> <given-names>E</given-names></name> <name><surname>Mitchell</surname> <given-names>P</given-names></name></person-group>. <article-title>Peripapillary retinal nerve fiber layer thickness in a population of 6-year-old children: Findings by optical coherence tomography.</article-title> <source><italic>Ophthalmology.</italic></source> (<year>2006</year>) <volume>113</volume>(<issue>9</issue>):<fpage>1583</fpage>&#x2013;<lpage>92</lpage>. <pub-id pub-id-type="doi">10.1016/j.ophtha.2006.02.067</pub-id> <pub-id pub-id-type="pmid">16949443</pub-id></citation></ref>
<ref id="B20"><label>20.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Raveendran</surname> <given-names>R</given-names></name> <name><surname>Bobier</surname> <given-names>W</given-names></name> <name><surname>Thompson</surname> <given-names>B</given-names></name></person-group>. <article-title>Reduced amblyopic eye fixation stability cannot be simulated using retinal-defocus-induced reductions in visual acuity.</article-title> <source><italic>Vision Res.</italic></source> (<year>2019</year>) <volume>154</volume>:<fpage>14</fpage>&#x2013;<lpage>20</lpage>. <pub-id pub-id-type="doi">10.1016/j.visres.2018.10.005</pub-id> <pub-id pub-id-type="pmid">30389388</pub-id></citation></ref>
<ref id="B21"><label>21.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Subramanian</surname> <given-names>V</given-names></name> <name><surname>Jost</surname> <given-names>R</given-names></name> <name><surname>Birch</surname> <given-names>EEA</given-names></name></person-group>. <article-title>quantitative study of fixation stability in amblyopia.</article-title> <source><italic>Invest Ophthalmol Vis Sci.</italic></source> (<year>2013</year>) <volume>54</volume>(<issue>3</issue>):<fpage>1998</fpage>&#x2013;<lpage>2003</lpage>. <pub-id pub-id-type="doi">10.1167/iovs.12-11054</pub-id> <pub-id pub-id-type="pmid">23372053</pub-id></citation></ref>
<ref id="B22"><label>22.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Myers</surname> <given-names>V</given-names></name> <name><surname>Gidlewski</surname> <given-names>N</given-names></name> <name><surname>Quinn</surname> <given-names>G</given-names></name> <name><surname>Miller</surname> <given-names>D</given-names></name> <name><surname>Dobson</surname> <given-names>V</given-names></name></person-group>. <article-title>Distance and near visual acuity, contrast sensitivity, and visual fields of 10-year-old children.</article-title> <source><italic>Arch Ophthalmol.</italic></source> (<year>1999</year>) <volume>117</volume>(<issue>1</issue>):<fpage>94</fpage>&#x2013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1001/archopht.117.1.94</pub-id> <pub-id pub-id-type="pmid">9930166</pub-id></citation></ref>
<ref id="B23"><label>23.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Huurneman</surname> <given-names>B</given-names></name> <name><surname>Boonstra</surname> <given-names>F</given-names></name> <name><surname>Cox</surname> <given-names>R</given-names></name> <name><surname>van Rens</surname> <given-names>G</given-names></name> <name><surname>Cillessen</surname> <given-names>A</given-names></name></person-group>. <article-title>Perceptual learning in children with visual impairment improves near visual acuity.</article-title> <source><italic>Invest Ophthalmol Vis Sci.</italic></source> (<year>2013</year>) <volume>54</volume>(<issue>9</issue>):<fpage>6208</fpage>&#x2013;<lpage>16</lpage>. <pub-id pub-id-type="doi">10.1167/iovs.13-12220</pub-id> <pub-id pub-id-type="pmid">23950157</pub-id></citation></ref>
<ref id="B24"><label>24.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yanni</surname> <given-names>S</given-names></name> <name><surname>Wang</surname> <given-names>J</given-names></name> <name><surname>Cheng</surname> <given-names>C</given-names></name> <name><surname>Locke</surname> <given-names>K</given-names></name> <name><surname>Wen</surname> <given-names>Y</given-names></name> <name><surname>Birch</surname> <given-names>D</given-names></name><etal/></person-group> <article-title>Normative reference ranges for the retinal nerve fiber layer, macula, and retinal layer thicknesses in children.</article-title> <source><italic>Am J Ophthalmol.</italic></source> (<year>2013</year>) <volume>155</volume>(<issue>2</issue>):<fpage>354</fpage>&#x2013;<lpage>60</lpage>. <pub-id pub-id-type="doi">10.1016/j.ajo.2012.08.010</pub-id> <pub-id pub-id-type="pmid">23127751</pub-id></citation></ref>
<ref id="B25"><label>25.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lee</surname> <given-names>Y</given-names></name> <name><surname>Ju</surname> <given-names>Y</given-names></name> <name><surname>Choi</surname> <given-names>D</given-names></name></person-group>. <article-title>Ganglion cell-inner plexiform layer thickness by swept-source optical coherence tomography in healthy korean children: Normative data and biometric correlations.</article-title> <source><italic>Sci Rep.</italic></source> (<year>2018</year>) <volume>8</volume>(<issue>1</issue>):<fpage>10605</fpage>. <pub-id pub-id-type="doi">10.1038/s41598-018-28870-4</pub-id> <pub-id pub-id-type="pmid">30006534</pub-id></citation></ref>
<ref id="B26"><label>26.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Runge</surname> <given-names>A</given-names></name> <name><surname>Remlinger</surname> <given-names>J</given-names></name> <name><surname>Abegg</surname> <given-names>M</given-names></name> <name><surname>Ferrazzini</surname> <given-names>T</given-names></name> <name><surname>Br&#x00FC;gger</surname> <given-names>D</given-names></name> <name><surname>Weigt-Usinger</surname> <given-names>K</given-names></name><etal/></person-group> <article-title>Retinal layer segmentation in a cohort of healthy children via optical coherence tomography.</article-title> <source><italic>PLoS One.</italic></source> (<year>2022</year>) <volume>17</volume>(<issue>11</issue>):<fpage>e276958</fpage>. <pub-id pub-id-type="doi">10.1371/journal.pone.0276958</pub-id> <pub-id pub-id-type="pmid">36327296</pub-id></citation></ref>
<ref id="B27"><label>27.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Nagarkatti-Gude</surname> <given-names>N</given-names></name> <name><surname>Gardiner</surname> <given-names>S</given-names></name> <name><surname>Fortune</surname> <given-names>B</given-names></name> <name><surname>Demirel</surname> <given-names>S</given-names></name> <name><surname>Mansberger</surname> <given-names>S</given-names></name></person-group>. <article-title>Optical coherence tomography segmentation errors of the retinal nerve fiber layer persist over time.</article-title> <source><italic>J Glaucoma.</italic></source> (<year>2019</year>) <volume>28</volume>(<issue>5</issue>):<fpage>368</fpage>&#x2013;<lpage>74</lpage>. <pub-id pub-id-type="doi">10.1097/IJG.0000000000001222</pub-id> <pub-id pub-id-type="pmid">30855415</pub-id></citation></ref>
<ref id="B28"><label>28.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mansberger</surname> <given-names>S</given-names></name> <name><surname>Menda</surname> <given-names>S</given-names></name> <name><surname>Fortune</surname> <given-names>B</given-names></name> <name><surname>Gardiner</surname> <given-names>S</given-names></name> <name><surname>Demirel</surname> <given-names>S</given-names></name></person-group>. <article-title>Automated segmentation errors when using optical coherence tomography to measure retinal nerve fiber layer thickness in glaucoma.</article-title> <source><italic>Am J Ophthalmol.</italic></source> (<year>2017</year>) <volume>174</volume>:<fpage>1</fpage>&#x2013;<lpage>08</lpage>. <pub-id pub-id-type="doi">10.1016/j.ajo.2016.10.020</pub-id> <pub-id pub-id-type="pmid">27818206</pub-id></citation></ref>
<ref id="B29"><label>29.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Maloca</surname> <given-names>P</given-names></name> <name><surname>Lee</surname> <given-names>A</given-names></name> <name><surname>de Carvalho</surname> <given-names>E</given-names></name> <name><surname>Okada</surname> <given-names>M</given-names></name> <name><surname>Fasler</surname> <given-names>K</given-names></name> <name><surname>Leung</surname> <given-names>I</given-names></name><etal/></person-group> <article-title>Validation of automated artificial intelligence segmentation of optical coherence tomography images.</article-title> <source><italic>PLoS One.</italic></source> (<year>2019</year>) <volume>14</volume>(<issue>8</issue>):<fpage>e220063</fpage>. <pub-id pub-id-type="doi">10.1371/journal.pone.0220063</pub-id> <pub-id pub-id-type="pmid">31419240</pub-id></citation></ref>
<ref id="B30"><label>30.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bayer</surname> <given-names>A</given-names></name> <name><surname>Akman</surname> <given-names>A</given-names></name></person-group>. <article-title>Artifacts and anatomic variations in optical coherence tomography.</article-title> <source><italic>Turk J Ophthalmol.</italic></source> (<year>2020</year>) <volume>50</volume>(<issue>2</issue>):<fpage>99</fpage>&#x2013;<lpage>106</lpage>. <pub-id pub-id-type="doi">10.4274/tjo.galenos.2019.78800</pub-id></citation></ref>
<ref id="B31"><label>31.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Li</surname> <given-names>A</given-names></name> <name><surname>Thompson</surname> <given-names>A</given-names></name> <name><surname>Asrani</surname> <given-names>S</given-names></name></person-group>. <article-title>Impact of artifacts from optical coherence tomography retinal nerve fiber layer and macula scans on detection of glaucoma progression.</article-title> <source><italic>Am J Ophthalmol.</italic></source> (<year>2021</year>) <volume>221</volume>:<fpage>235</fpage>&#x2013;<lpage>45</lpage>. <pub-id pub-id-type="doi">10.1016/j.ajo.2020.08.018</pub-id> <pub-id pub-id-type="pmid">32818450</pub-id></citation></ref>
</ref-list>
</back>
</article>
