<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Med.</journal-id>
<journal-title>Frontiers in Medicine</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Med.</abbrev-journal-title>
<issn pub-type="epub">2296-858X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fmed.2025.1487557</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Medicine</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Analytical evaluation of the performances of point-of-care and benchtop procalcitonin assays in comparison with the B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S PCT sensitive KRYPTOR assay</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" equal-contrib="yes">
<name><surname>He</surname> <given-names>Ruiqing</given-names></name>
<xref ref-type="author-notes" rid="fn002"><sup>&#x2020;</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/2821459/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author" equal-contrib="yes">
<name><surname>Sun</surname> <given-names>Xiaobing</given-names></name>
<xref ref-type="author-notes" rid="fn002"><sup>&#x2020;</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Su</surname> <given-names>Ling</given-names></name>
<role content-type="https://credit.niso.org/contributor-roles/data-curation/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Zhu</surname> <given-names>Ting</given-names></name>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author" corresp="yes" equal-contrib="yes">
<name><surname>Wu</surname> <given-names>Jiong</given-names></name>
<xref ref-type="corresp" rid="c001"><sup>&#x002A;</sup></xref>
<xref ref-type="author-notes" rid="fn003"><sup>&#x2021;</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author" corresp="yes" equal-contrib="yes">
<name><surname>Hou</surname> <given-names>Qi</given-names></name>
<xref ref-type="corresp" rid="c002"><sup>&#x002A;</sup></xref>
<xref ref-type="author-notes" rid="fn003"><sup>&#x2021;</sup></xref>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/project-administration/"/>
<role content-type="https://credit.niso.org/contributor-roles/validation/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
</contrib-group>
<aff><institution>Department of Clinical Laboratory, Shanghai Jiahui International Hospital</institution>, <addr-line>Shanghai</addr-line>, <country>China</country></aff>
<author-notes>
<fn fn-type="edited-by"><p>Edited by: Zezhi Li, Guangzhou Medical University, China</p></fn>
<fn fn-type="edited-by"><p>Reviewed by: Meihong Xiu, Peking University, China</p><p>Beili Wang, Fudan University, China</p></fn>
<corresp id="c001">&#x002A;Correspondence: Jiong Wu, <email>joe.wu@jiahui.com</email></corresp>
<corresp id="c002">Qi Hou, <email>grace.hou@jiahui.com</email></corresp>
<fn fn-type="equal" id="fn002"><p><sup>&#x2020;</sup>These authors have contributed equally to this work and share first authorship</p></fn>
<fn fn-type="equal" id="fn003"><p><sup>&#x2021;</sup>These authors have contributed equally to this work</p></fn>
</author-notes>
<pub-date pub-type="epub">
<day>17</day>
<month>06</month>
<year>2025</year>
</pub-date>
<pub-date pub-type="collection">
<year>2025</year>
</pub-date>
<volume>12</volume>
<elocation-id>1487557</elocation-id>
<history>
<date date-type="received">
<day>03</day>
<month>09</month>
<year>2024</year>
</date>
<date date-type="accepted">
<day>27</day>
<month>05</month>
<year>2025</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x00A9; 2025 He, Sun, Su, Zhu, Wu and Hou.</copyright-statement>
<copyright-year>2025</copyright-year>
<copyright-holder>He, Sun, Su, Zhu, Wu and Hou</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license>
</permissions>
<abstract>
<sec>
<title>Background</title>
<p>Procalcitonin (PCT) is increasingly utilized in clinical laboratories, leading to the proliferation of commercial PCT assays. However, not all of these assays are traceable to the B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S PCT standard, which is integral to established PCT clinical algorithms. This study evaluates the suitability of three non-B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S PCT assays for the application of these algorithms.</p>
</sec>
<sec>
<title>Methods</title>
<p>The study assessed PCT assays from Wondfo (PCT-W), Getein (PCT-G), and Snibe (PCT-S), comparing them to the B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S PCT sensitive KRYPTOR assay (PCT-KR). Analytical performance, including linearity, imprecision, and recovery, was evaluated. Additionally, a method comparison study involving 350 routine serum samples was conducted to assess agreement, bias, and correlation with the KRYPTOR assay.</p>
</sec>
<sec>
<title>Results</title>
<p>The KRYPTOR assay exhibited a maximum imprecision of 4.65%, while Wondfo, Getein, and Snibe showed higher imprecision at 8.38, 10.25, and 15.67%, respectively. Wondfo and Getein assays exceeded the maximum allowable deviation from linearity, and the Snibe assay failed the recovery assessment. Passing-Bablok regressions for low-range samples indicated significant bias for Wondfo (PCT-W = 0.663 PCT-KR + 0.076) and Getein (PCT-G = 0.838 PCT-KR&#x2212;0.06). Agreement with the KRYPTOR assay was Kc = 0.83 and Kc = 0.87 for Wondfo and Getein, respectively, with substantial agreement in lower respiratory tract infections (LRTI) at Kc = 0.78 and Kc = 0.65. The Snibe assay showed better overall agreement (PCT-S = 1.002 PCT-KR&#x2212;0.069), with Kc = 0.92 for sepsis and Kc = 0.76 for LRTI.</p>
</sec>
<sec>
<title>Conclusion</title>
<p>Despite high overall agreement with the KRYPTOR assay, the evaluated assays (Wondfo, Getein, and Snibe) exhibit insufficient analytical performance at low PCT concentrations, which may limit their reliability in the diagnosis and management of sepsis and LRTI.</p>
</sec>
</abstract>
<kwd-group>
<kwd>procalcitonin</kwd>
<kwd>algorithms</kwd>
<kwd>respiratory tract infections</kwd>
<kwd>sepsis</kwd>
<kwd>comparison</kwd>
</kwd-group>
<counts>
<fig-count count="2"/>
<table-count count="4"/>
<equation-count count="0"/>
<ref-count count="30"/>
<page-count count="8"/>
<word-count count="4956"/>
</counts>
<custom-meta-wrap>
<custom-meta>
<meta-name>section-at-acceptance</meta-name>
<meta-value>Precision Medicine</meta-value>
</custom-meta>
</custom-meta-wrap>
</article-meta>
</front>
<body>
<sec id="S1" sec-type="intro">
<title>Introduction</title>
<p>Procalcitonin (PCT) is the prohormone precursor of calcitonin, encoded by the CALC-1 gene, which is primarily transcribed in thyroid C-cells that produce and secrete calcitonin (<xref ref-type="bibr" rid="B1">1</xref>). Under normal physiological conditions, PCT is present in minimal concentrations in the serum (<xref ref-type="bibr" rid="B2">2</xref>). However, following pro-inflammatory triggers, especially those related to bacterial infections, PCT production can become significant in various cell types throughout the body. PCT levels can rise rapidly, within 3 to 6 h, after a systemic bacterial insult (<xref ref-type="bibr" rid="B1">1</xref>, <xref ref-type="bibr" rid="B3">3</xref>, <xref ref-type="bibr" rid="B4">4</xref>). This rapid response has led to the adoption of PCT as a biomarker for infection, making it a valuable diagnostic tool for suspected bacterial infections (<xref ref-type="bibr" rid="B2">2</xref>, <xref ref-type="bibr" rid="B5">5</xref>). Additionally, PCT has been increasingly used to guide antibiotic treatment in patients with lower respiratory tract infections (LRTI) and sepsis (<xref ref-type="bibr" rid="B6">6</xref>).</p>
<p>The World Health Organization has recognized the importance of procalcitonin (PCT) by including it in its list of essential diagnostics (<xref ref-type="bibr" rid="B7">7</xref>), and many international guidelines highlight its utility for various clinical applications (<xref ref-type="bibr" rid="B8">8</xref>&#x2013;<xref ref-type="bibr" rid="B11">11</xref>). In China, several expert consensus documents have been developed, providing detailed guidance on the use of PCT. As early as 2012, the Chinese Expert Consensus on Emergency Clinical Application of Procalcitonin recommended the use of specific PCT cut-offs&#x2014;0.1, 0.25, and 0.5 &#x03BC;g/L&#x2014;for diagnostic and therapeutic assessments. Additionally, algorithms based on proportional changes in PCT concentrations of 30% and 90% were introduced (<xref ref-type="bibr" rid="B12">12</xref>). Overall, Chinese consensus documents emphasize the use of PCT in diagnosing sepsis (<xref ref-type="bibr" rid="B12">12</xref>&#x2013;<xref ref-type="bibr" rid="B14">14</xref>) and lower respiratory tract infections (LRTI) (<xref ref-type="bibr" rid="B12">12</xref>, <xref ref-type="bibr" rid="B15">15</xref>&#x2013;<xref ref-type="bibr" rid="B17">17</xref>), guiding antibiotic treatment (<xref ref-type="bibr" rid="B12">12</xref>&#x2013;<xref ref-type="bibr" rid="B17">17</xref>), and in pediatric and neonatal care (<xref ref-type="bibr" rid="B18">18</xref>, <xref ref-type="bibr" rid="B19">19</xref>).</p>
<p>National and international guidelines recommend using assays traceable to the B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S PCT standard, as the clinical cut-offs and algorithms for PCT testing were originally established using B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S PCT assays (<xref ref-type="bibr" rid="B9">9</xref>). In China, PCT testing is widely available, with numerous assays offered both in point-of-care formats and on large, automated immunoassay analyzers (<xref ref-type="bibr" rid="B20">20</xref>). Over the years, several immunoassay manufacturers have obtained a B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S PCT license, ensuring alignment with the B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S PCT gold standard. Companies such as Abbott, bioM&#x00E9;rieux, DiaSorin, Fujirebio, Hybiome, LSI Medience, Quidel Ortho, Roche, Siemens, and ThermoFisher Scientific all offer B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S PCT assays on their immunoassay platforms and participate in the B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S PCT harmonization program (<xref ref-type="bibr" rid="B9">9</xref>). However, many other PCT assays do not clearly define their traceability to the B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S PCT standard, and there is a lack of information regarding the alignment of these non-B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S assays with the B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S PCT gold standard (<xref ref-type="bibr" rid="B9">9</xref>).</p>
<p>This study aims to shed light on the alignment of non-B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S PCT assays with a B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S PCT assay, specifically addressing whether the same diagnostic criteria and algorithms can be applied to non-B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S assays. Three such PCT assays, commercialized by Wondfo, Getein, and Snibe, were selected for evaluation, with particular focus on their performance when applying the low-range cut-offs (0.1 &#x03BC;g/L and 0.25 &#x03BC;g/L) established in common guidelines. Wondfo, Getein, and Snibe were selected based on their dominant market shares in China&#x2019;s POCT sector (28, 22, and 18%, respectively; 2023 data) and their manufacturer-claimed advantages: rapid turnaround (Wondfo: 15 min), automated platform compatibility (Getein), and broad analytical range (Snibe: 0.04 &#x03BC;g/L&#x2013;100 &#x03BC;g/L).</p>
</sec>
<sec id="S2" sec-type="materials|methods">
<title>Materials and methods</title>
<sec id="S2.SS1">
<title>Instruments and reagents</title>
<p>Three commonly used immunoassays were compared with the B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S PCT sensitive KRYPTOR assay, which is performed on the KRYPTOR Compact Plus instrument (B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S GmbH, Hennigsdorf, Germany, abbreviated as PCT-KR). The assays compared were the Finecare PCT assay, run on the FS-114 analyzer (Guangzhou Wondfo Biotech, Guangzhou, China, abbreviated as PCT-W); the Getein Biotech Procalcitonin assay kit, run on the Getein 1600 analyzer (Getein Biotech, Nanjing, China, abbreviated as PCT-G); and the Maglumi PCT Assay Kit, performed on the Maglumi 4000 Plus analyzer (Snibe, Shenzhen, China, abbreviated as PCT-S). Unless otherwise specified, reagents and protocols provided in the instructions for use of each respective diagnostic assay were followed. The core technologies and formats of these assays differ: PCT-W and PCT-G are based on lateral flow immunofluorescence, with manual and automated sample handling, respectively (<xref ref-type="bibr" rid="B21">21</xref>, <xref ref-type="bibr" rid="B22">22</xref>). In contrast, PCT-S is a chemiluminescence assay that utilizes isoluminol and fluorescein chemistry in combination with magnetic beads. The KRYPTOR assay is unique in that it does not involve a solid-phase step, instead employing time-resolved amplification cryptate emission (TRACE) technology (<xref ref-type="bibr" rid="B23">23</xref>).</p>
</sec>
<sec id="S2.SS2">
<title>Linearity</title>
<p>Two sample pools were prepared: one with low PCT concentrations using samples from healthy subjects, and another with high PCT concentrations using samples from patients with elevated PCT levels. To create the linearity test samples, aliquots from the high concentration pool were diluted using the low concentration pool. Five scalar dilutions of the high concentration pool were used to generate five of the six linearity test samples, covering concentrations up to the upper limit of the direct measurement range for each assay. Additionally, a low concentration pool sample was tested. Each sample was measured in triplicate, and the resulting data were visually inspected. Linearity deviations were evaluated according to CLSI EP6, 2nd Edition, with a 15% allowable deviation from linearity (ADL). Pearson&#x2019;s linear correlation coefficients (r) were calculated to assess alignment with manufacturer specifications. The measuring ranges for the three evaluated assays were as follows: Snibe (0.04 &#x03BC;g/L&#x2013;100.0 &#x03BC;g/L), Wondfo (0.1 &#x03BC;g/L&#x2013;100.0 &#x03BC;g/L), and Getein (0.1 &#x03BC;g/L&#x2013;50.0 &#x03BC;g/L), with analytical detection limits of Snibe (0.04 &#x03BC;g/L), Wondfo (0.1 &#x03BC;g/L), and Getein (0.1 &#x03BC;g/L) (<xref ref-type="bibr" rid="B21">21</xref>, <xref ref-type="bibr" rid="B22">22</xref>, <xref ref-type="bibr" rid="B24">24</xref>).</p>
</sec>
<sec id="S2.SS3">
<title>Imprecision</title>
<p>Three serum pools were prepared at concentrations approximating key PCT cut-offs for LRTI and sepsis: 0.25, 0.5, and 2 &#x03BC;g/L. Each sample was tested in triplicate over five consecutive days. Repeatability, measured as intraday imprecision, and reproducibility, reflecting total laboratory imprecision, were then calculated.</p>
</sec>
<sec id="S2.SS4">
<title>Recovery</title>
<p>Following the China National Accreditation Service for Conformity Assessment (CNAS) guidelines (CNAS-GL037), single patient routine serum PCT samples were mixed with standard solutions. The volume of the standard solution added never exceeded 10% of the total sample volume. For each assay, two sample solutions with different concentrations of PCT were prepared using a single patient sample. These sample solutions were measured in triplicate, and the mean deviations from the target recovery concentrations were calculated. The target recovery values were established by adding the initially measured serum sample concentrations to the PCT concentration contributed by the standard solutions. The standard solution concentrations provided by the respective manufacturers were used in these calculations. Recovery results were considered acceptable if they fell within &#x00B1; 10% of the target recovery value. The Snibe PCT High Calibrator Solution (Snibe, Shenzhen, China) was used as the standard solution for samples tested with PCT-S, while the remaining samples were prepared using the B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S PCT Sensitive KRYPTOR CAL standard solution (B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S, Hennigsdorf, Germany).</p>
</sec>
<sec id="S2.SS5">
<title>Method comparison</title>
<p>A total of 350 serum samples were collected from patients aged 18&#x2013;85 years (mean: 45.3 years; male: 52%, female: 48%) with suspected bacterial infections. Testing was conducted in parallel on all instruments within 24 h of sample arrival at the laboratory. All serum samples were centrifuged and separated within 2 h after collection, stored in a &#x2212;80&#x00B0;C freezer without undergoing freeze-thaw cycles. Numerical results from samples yielding PCT-KR values between the limit of quantification (LoQ) and 2 &#x03BC;g/L, as well as up to 100 &#x03BC;g/L, were included in the bias and correlation analyses. Bias values of the new assays were compared with those obtained from PCT-KR using normalized Bland-Altman plots and Passing-Bablok regression analysis. Correlation was assessed using Spearman&#x2019;s rank correlation coefficient (rS). Cohen&#x2019;s Kappa coefficients (K<sub><italic>C</italic></sub>) were calculated to establish agreement with PCT-KR. When classifying patient samples, concentration ranges established for the diagnosis of LRTI and systemic bacterial infections and sepsis (see <xref ref-type="table" rid="T1">Table 1</xref>) were used. The interpretation of Kappa (KC) values followed the criteria established by Landis and Koch: KC &#x003C; 0 indicates no agreement; KC = 0 to 0.20 represents slight agreement; KC = 0.21 to 0.40 signifies fair agreement; KC = 0.41 to 0.60 denotes moderate agreement; KC = 0.61 to 0.80 reflects substantial agreement; and KC = 0.81 to 1.0 indicates perfect agreement (<xref ref-type="bibr" rid="B25">25</xref>).</p>
<table-wrap position="float" id="T1">
<label>TABLE 1</label>
<caption><p>Class categorization according to reference PCT concentration ranges employed for LRTI and systemic bacterial infection-sepsis diagnosis (<xref ref-type="bibr" rid="B21">21</xref>&#x2013;<xref ref-type="bibr" rid="B24">24</xref>).</p></caption>
<table cellspacing="5" cellpadding="5" frame="box" rules="all">
<thead>
<tr>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;">LRTI classes</td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;">Systemic bacterial infection/<break/> sepsis classes</td>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Class 0: &#x003C; 0.1 &#x03BC;g/L</td>
<td valign="top" align="left">Class 0: &#x003C; 0.5 &#x03BC;g/L</td>
</tr>
<tr>
<td valign="top" align="left">Class 1: &#x2265; 0.1 &#x03BC;g/L, &#x003C; 0.25 &#x03BC;g/L</td>
<td valign="top" align="left">Class 1: &#x2265; 0.5 &#x03BC;g/L, &#x003C; 2 &#x03BC;g/L</td>
</tr>
<tr>
<td valign="top" align="left">Class 2: &#x2265; 0.25 &#x03BC;g/L, &#x003C; 0.5 &#x03BC;g/L</td>
<td valign="top" align="left">Class 2: &#x2265; 2 &#x03BC;g/L, &#x003C; 10 &#x03BC;g/L</td>
</tr>
<tr>
<td valign="top" align="left">Class 3: &#x2265; 0.5 &#x03BC;g/L</td>
<td valign="top" align="left">Class 3: &#x2265; 10 &#x03BC;g/L</td>
</tr>
</tbody>
</table></table-wrap>
</sec>
</sec>
<sec id="S3" sec-type="results">
<title>Results</title>
<sec id="S3.SS1">
<title>Linearity</title>
<p>PCT-KR deviations did not exceed the ADL throughout the measured range while featuring a high linear correlation (<italic>r</italic> = 0.997). Deviations exceeding ADL were observed for both the PCT-W and PCT-G assays. PCT-W displayed deviations of &#x2212;26% and &#x2212;17% (respectively, corresponding expected values were 80.25 &#x03BC;g/L and 16.18 &#x03BC;g/L). A maximum-19% deviation (expected value: 31.54 &#x03BC;g/L) was observed in PCT-G&#x2019;s assay (see <xref ref-type="fig" rid="F1">Figure 1</xref>). PCT-W and PCT-G both displayed high linear correlations (respectively, <italic>r</italic> = 0.964 and <italic>r</italic> = 0.987). Despite producing a persistent readily visible deviation from the predicted regression line above 30 &#x03BC;g/L (see <xref ref-type="fig" rid="F1">Figure 1</xref>), the PCT-S assay didn&#x2019;t exceed the established ADL and its correlation coefficient was very high (<italic>r</italic> = 0.999).</p>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption><p>Linearity plots of the average measured values confronted with the predicted weighted least square regression line. WLS, weighted least square.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmed-12-1487557-g001.tif"/>
</fig>
</sec>
<sec id="S3.SS2">
<title>Imprecision</title>
<p>As displayed in <xref ref-type="table" rid="T2">Table 2</xref>, total laboratory imprecision for the PCT-KR assay is rather low and stable, ranging from 4.42% to 4.65% across concentrations, meanwhile, all other assays display higher imprecisions. The PCT-W and PCT-G assays showed total laboratory imprecision with coefficients of variation (CV) ranging from 6.07% to 8.38% and 8.57% to 10.25%, respectively. The PCT-S assay exhibited the highest total laboratory reproducibility CV, reaching 15.67%. Notably, the PCT-S assay demonstrated a significant increase in imprecision when comparing high and intermediate concentrations to the low concentration, with CVs of approximately 7.18% at &#x223C;2 &#x03BC;g/L, 8.21% at &#x223C;0.5 &#x03BC;g/L, and 15.67% at &#x223C;0.25 &#x03BC;g/L.</p>
<table-wrap position="float" id="T2">
<label>TABLE 2</label>
<caption><p>Imprecision results based on 15 measurements per sample and assay.</p></caption>
<table cellspacing="5" cellpadding="5" frame="box" rules="all">
<thead>
<tr>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;">Assay</td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;">Sample</td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;">Mean</td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;">Repeatability CV</td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;">Reproducibility CV</td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;">95% CI % deviation</td>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">KRYPTOR</td>
<td valign="top" align="left" rowspan="4">1 (&#x223C;0.25 &#x03BC;g/L)</td>
<td valign="top" align="left">0.248</td>
<td valign="top" align="left">2.08%</td>
<td valign="top" align="left">4.64%</td>
<td valign="top" align="left">3.1% to 12.5%</td>
</tr>
<tr>
<td valign="top" align="left">Wondfo</td>
<td valign="top" align="left">0.269</td>
<td valign="top" align="left">8.38%</td>
<td valign="top" align="left">8.38%</td>
<td valign="top" align="left">6.5% to 16.0%</td>
</tr>
<tr>
<td valign="top" align="left">Getein</td>
<td valign="top" align="left">0.297</td>
<td valign="top" align="left">8.57%</td>
<td valign="top" align="left">8.57%</td>
<td valign="top" align="left">6.8% to 15.4%</td>
</tr>
<tr>
<td valign="top" align="left">Snibe</td>
<td valign="top" align="left">0.249</td>
<td valign="top" align="left">10.71%</td>
<td valign="top" align="left">15.67%</td>
<td valign="top" align="left">11.4% to 38.5%</td>
</tr>
<tr>
<td valign="top" align="left">KRYPTOR</td>
<td valign="top" align="left" rowspan="4">2 (&#x223C;0.5 &#x03BC;g/L)</td>
<td valign="top" align="left">0.418</td>
<td valign="top" align="left">2.39%</td>
<td valign="top" align="left">4.65%</td>
<td valign="top" align="left">3.2% to 12.3%</td>
</tr>
<tr>
<td valign="top" align="left">Wondfo</td>
<td valign="top" align="left">0.401</td>
<td valign="top" align="left">4.50%</td>
<td valign="top" align="left">6.07%</td>
<td valign="top" align="left">4.5% to 14.4%</td>
</tr>
<tr>
<td valign="top" align="left">Getein</td>
<td valign="top" align="left">0.493</td>
<td valign="top" align="left">6.20%</td>
<td valign="top" align="left">8.66%</td>
<td valign="top" align="left">6.4% to 20.9%</td>
</tr>
<tr>
<td valign="top" align="left">Snibe</td>
<td valign="top" align="left">0.413</td>
<td valign="top" align="left">3.05%</td>
<td valign="top" align="left">8.21%</td>
<td valign="top" align="left">5.3% to 22.6%</td>
</tr>
<tr>
<td valign="top" align="left">KRYPTOR</td>
<td valign="top" align="left" rowspan="4">3 (&#x223C;2.0 &#x03BC;g/L)</td>
<td valign="top" align="left">2.065</td>
<td valign="top" align="left">2.77%</td>
<td valign="top" align="left">4.42%</td>
<td valign="top" align="left">3.1% to 11.2%</td>
</tr>
<tr>
<td valign="top" align="left">Wondfo</td>
<td valign="top" align="left">1.638</td>
<td valign="top" align="left">7.11%</td>
<td valign="top" align="left">8.02%</td>
<td valign="top" align="left">6.2% to 17.2%</td>
</tr>
<tr>
<td valign="top" align="left">Getein</td>
<td valign="top" align="left">1.977</td>
<td valign="top" align="left">8.73%</td>
<td valign="top" align="left">10.25%</td>
<td valign="top" align="left">7.8% to 22.6%</td>
</tr>
<tr>
<td valign="top" align="left">Snibe</td>
<td valign="top" align="left">1.955</td>
<td valign="top" align="left">2.09%</td>
<td valign="top" align="left">7.18%</td>
<td valign="top" align="left">4.5% to 20.1%</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn><p>Repeatability and reproducibility refer, respectively, to intraday imprecision and total laboratory imprecision.</p></fn>
</table-wrap-foot>
</table-wrap>
</sec>
<sec id="S3.SS3">
<title>Recovery results</title>
<p>The PCT-KR assay demonstrated good recovery performance, with values ranging from &#x2212;0.79% to &#x2212;3.83%. The PCT-S assay also showed favorable recovery for the low concentration sample (&#x2212;1.87%). However, the other assays exhibited excessively high recovery values at various concentrations, exceeding the established &#x00B1; 10% acceptance criterion (see <xref ref-type="table" rid="T3">Table 3</xref>).</p>
<table-wrap position="float" id="T3">
<label>TABLE 3</label>
<caption><p>Summary of recovery assay results: original patient sample PCT concentrations according to the respective assays are featured in the mean control sample.</p></caption>
<table cellspacing="5" cellpadding="5" frame="box" rules="all">
<thead>
<tr>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;">Assay</td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;">Mean recovery sample [&#x03BC;g/L]</td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;">Mean control sample [&#x03BC;g/L]</td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;">Standard sample [&#x03BC;g/L]</td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;">Volume ratio (&#x2264; 0.1)</td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;">% Recovery</td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;">% Deviation</td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;">% Recovery within &#x00B1; 10%</td>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">KRYPTOR CP</td>
<td valign="top" align="left">2.07</td>
<td valign="top" align="left">0.24</td>
<td valign="top" align="left">26.24</td>
<td valign="top" align="left">0.0728</td>
<td valign="top" align="left">96.17%</td>
<td valign="top" align="left">&#x2212;3.83%</td>
<td valign="top" align="left">Yes</td>
</tr>
<tr>
<td valign="top" align="left">KRYPTOR CP</td>
<td valign="top" align="left">14.87</td>
<td valign="top" align="left">13.57</td>
<td valign="top" align="left">26.75</td>
<td valign="top" align="left">0.1</td>
<td valign="top" align="left">99.21%</td>
<td valign="top" align="left">&#x2212;0.79%</td>
<td valign="top" align="left">Yes</td>
</tr>
<tr>
<td valign="top" align="left">Wondfo</td>
<td valign="top" align="left">0.98</td>
<td valign="top" align="left">0.30</td>
<td valign="top" align="left">25.62</td>
<td valign="top" align="left">0.0225</td>
<td valign="top" align="left">117.95%</td>
<td valign="top" align="left">11.95%</td>
<td valign="top" align="left">No</td>
</tr>
<tr>
<td valign="top" align="left">Wondfo</td>
<td valign="top" align="left">4.24</td>
<td valign="top" align="left">1.30</td>
<td valign="top" align="left">25.35</td>
<td valign="top" align="left">0.1</td>
<td valign="top" align="left">118.32%</td>
<td valign="top" align="left">18.32%</td>
<td valign="top" align="left">No</td>
</tr>
<tr>
<td valign="top" align="left">Getein</td>
<td valign="top" align="left">2.06</td>
<td valign="top" align="left">0.31</td>
<td valign="top" align="left">25.87</td>
<td valign="top" align="left">0.0475</td>
<td valign="top" align="left">142.37%</td>
<td valign="top" align="left">42.37%</td>
<td valign="top" align="left">No</td>
</tr>
<tr>
<td valign="top" align="left">Getein</td>
<td valign="top" align="left">9.48</td>
<td valign="top" align="left">6.97</td>
<td valign="top" align="left">25.92</td>
<td valign="top" align="left">0.1</td>
<td valign="top" align="left">123.59%</td>
<td valign="top" align="left">23.59%</td>
<td valign="top" align="left">No</td>
</tr>
<tr>
<td valign="top" align="left">Snibe</td>
<td valign="top" align="left">1.88</td>
<td valign="top" align="left">0.34</td>
<td valign="top" align="left">41.87</td>
<td valign="top" align="left">0.0375</td>
<td valign="top" align="left">98.13%</td>
<td valign="top" align="left">&#x2212;1.87%</td>
<td valign="top" align="left">Yes</td>
</tr>
<tr>
<td valign="top" align="left">Snibe</td>
<td valign="top" align="left">13.30</td>
<td valign="top" align="left">9.52</td>
<td valign="top" align="left">42.13</td>
<td valign="top" align="left">0.1</td>
<td valign="top" align="left">112.56%</td>
<td valign="top" align="left">12.56%</td>
<td valign="top" align="left">No</td>
</tr>
</tbody>
</table></table-wrap>
</sec>
<sec id="S3.SS4">
<title>Method comparison</title>
<p><xref ref-type="table" rid="T4">Table 4</xref> presents the results from correlation calculations and Passing-Bablok regression analyses. When comparing assays from the limit of quantitation (LoQ) to 100 &#x03BC;g/L, the PCT-W, PCT-G, and PCT-S assays showed high Spearman correlations with the PCT-KR assay (respectively, rS = 0.962; rS = 0.976; and rS = 0.975). For the PCT-W assay, Passing-Bablok regression revealed a moderate proportional bias with a positive intercept, indicating some constant bias (equation: PCT-W = 0.724 PCT-KR + 0.056). In contrast, the PCT-G and PCT-S assays had slopes close to 1 and negative constant bias intercepts (equations: PCT-G = 0.94 PCT-KR&#x2212;0.088 and PCT-S = 0.968 PCT-KR&#x2212;0.06).</p>
<table-wrap position="float" id="T4">
<label>TABLE 4</label>
<caption><p>Passing-Bablok regression results and Spearman correlation coefficients for samples from limit of quantitation to 2 &#x03BC;g/L and 100 &#x03BC;g/L, respectively; Cohen&#x2019;s Kappa values for agreement in the application of LRTI and systemic bacterial infection-sepsis classifications for all samples.</p></caption>
<table cellspacing="5" cellpadding="5" frame="box" rules="all">
<thead>
<tr>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;"></td>
<td valign="top" align="left" colspan="4" style="color:#ffffff;background-color: #7f8080;">LoQ to 2 &#x03BC;g/L</td>
<td valign="top" align="left" colspan="4" style="color:#ffffff;background-color: #7f8080;">LoQ to 100 &#x03BC;g/L</td>
<td valign="top" align="left" colspan="3" style="color:#ffffff;background-color: #7f8080;">All samples</td>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;"></td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;"></td>
<td valign="top" align="left" colspan="2" style="color:#ffffff;background-color: #7f8080;"><bold>P-B regression</bold></td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;"><bold>Corr.</bold></td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;"></td>
<td valign="top" align="left" colspan="2" style="color:#ffffff;background-color: #7f8080;"><bold>P-B regression</bold></td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;"><bold>Corr.</bold></td>
<td valign="top" align="left" colspan="3" style="color:#ffffff;background-color: #7f8080;"><bold>Classification agreement</bold></td>
</tr>
<tr>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;"><bold>Assay</bold></td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;"><bold><italic>N</italic></bold></td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;"><bold>Intercept</bold></td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;"><bold>Slope</bold></td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;"><bold>r<sub><italic>s</italic></sub></bold></td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;"><bold><italic>N</italic></bold></td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;"><bold>Intercept</bold></td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;"><bold>Slope</bold></td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;"><bold>r<sub><italic>s</italic></sub></bold></td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;"><bold><italic>N</italic></bold></td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;"><bold>LRTI K<sub><italic>C</italic></sub></bold></td>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;"><bold>Sepsis K<sub><italic>C</italic></sub></bold></td>
</tr>
<tr>
<td valign="top" align="left">Wondfo</td>
<td valign="top" align="left">196</td>
<td valign="top" align="left">0.076</td>
<td valign="top" align="left">0.663</td>
<td valign="top" align="left">0.901</td>
<td valign="top" align="left">273</td>
<td valign="top" align="left">0.056</td>
<td valign="top" align="left">0.724</td>
<td valign="top" align="left">0.962</td>
<td valign="top" align="left">350</td>
<td valign="top" align="left">0.78</td>
<td valign="top" align="left">0.83</td>
</tr>
<tr>
<td valign="top" align="left">Getein</td>
<td valign="top" align="left">183</td>
<td valign="top" align="left">&#x2212;0.060</td>
<td valign="top" align="left">0.838</td>
<td valign="top" align="left">0.938</td>
<td valign="top" align="left">254</td>
<td valign="top" align="left">&#x2212;0.088</td>
<td valign="top" align="left">0.940</td>
<td valign="top" align="left">0.976</td>
<td valign="top" align="left">350</td>
<td valign="top" align="left">0.65</td>
<td valign="top" align="left">0.87</td>
</tr>
<tr>
<td valign="top" align="left">Snibe</td>
<td valign="top" align="left">210</td>
<td valign="top" align="left">&#x2212;0.069</td>
<td valign="top" align="left">1.002</td>
<td valign="top" align="left">0.939</td>
<td valign="top" align="left">286</td>
<td valign="top" align="left">&#x2212;0.060</td>
<td valign="top" align="left">0.968</td>
<td valign="top" align="left">0.975</td>
<td valign="top" align="left">350</td>
<td valign="top" align="left">0.76</td>
<td valign="top" align="left">0.92</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn><p>LoQ, limit of quantitation; P-B, Passing-Bablok; Corr., correlation.</p></fn>
</table-wrap-foot>
</table-wrap>
<p>Within the LoQ to 2 &#x03BC;g/L range, assay performances varied. PCT-W and PCT-G exhibited larger proportional bias slopes (equations: PCT-W = 0.663 PCT-KR + 0.076 and PCT-G = 0.838 PCT-KR&#x2212;0.06, see <xref ref-type="fig" rid="F2">Figures 2A, C</xref>), indicating increased proportional bias at low concentrations. Correlation results for PCT-W, PCT-G, and PCT-S were high (respectively, rS = 0.901; rS = 0.938; and rS = 0.939). The regression for PCT-S (PCT-S = 1.002 PCT-KR&#x2212;0.069) closely aligned with the results from the LoQ to 100 &#x03BC;g/L range. Overall, analysis of discordances featured in the Passing-Bablok regression plots points to a poorer agreement at low concentrations (see <xref ref-type="fig" rid="F2">Figures 2A, C, E</xref>). <xref ref-type="table" rid="T4">Table 4</xref> shows the Kappa coefficient agreement between the assays. The PCT-W assay demonstrated relatively close Kappa values for both LRTI and sepsis classifications (respectively, KC = 0.78 and KC = 0.83). Most misclassifications occurred around the 0.5 &#x03BC;g/L cut-off, with significant increases in bias observed at and below this cut-off, as seen in the Bland-Altman plot (<xref ref-type="fig" rid="F2">Figures 2A, B</xref>). The PCT-G assay had the lowest concordance for LRTI (KC = 0.65) but performed better for sepsis classification (KC = 0.87). Similarly, the PCT-S assay showed better classification agreement for sepsis (KC = 0.92) compared to LRTI (KC = 0.76). Notably, a positive bias trend for higher sample concentrations was observed in the bias plots for both PCT-G and PCT-S (<xref ref-type="fig" rid="F2">Figures 2D, F</xref>).</p>
<fig id="F2" position="float">
<label>FIGURE 2</label>
<caption><p>Regression and normalized bias plots for the Wondfo [respectively, <bold>(A,B)</bold>], Getein [respectively, <bold>(C,D)</bold>], and Snibe [respectively, <bold>(E,F)</bold>] assays versus the KRYPTOR. Low-range diagnostic cut-offs are highlighted in all plots, these being 0.1, 0.25, and 0.5 &#x03BC;g/L.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmed-12-1487557-g002.tif"/>
</fig>
</sec>
</sec>
<sec id="S4" sec-type="discussion">
<title>Discussion</title>
<p>The PCT-KR assay demonstrated total in-laboratory precision, linearity, and recovery consistent with the manufacturer&#x2019;s specifications (<xref ref-type="bibr" rid="B23">23</xref>). In contrast, all three other assays did not meet the recovery specifications outlined in their instructions for use (<xref ref-type="bibr" rid="B21">21</xref>, <xref ref-type="bibr" rid="B22">22</xref>, <xref ref-type="bibr" rid="B24">24</xref>). It should be noted that PCT-W and PCT-G were tested using the PCT-KR standard solution, but the commutability of this standard with PCT-W and PCT-G has not been established. Additionally, PCT-W and PCT-G did not meet the linear correlation values specified in their documentation (<xref ref-type="bibr" rid="B21">21</xref>, <xref ref-type="bibr" rid="B22">22</xref>).</p>
<p>While the Kappa coefficients of agreement for sepsis cut-offs were above 0.8 for all three assays, the agreements for lower respiratory tract infection (LRTI) cut-offs were below this threshold, showing only substantial agreement. This was unexpected given that the limits of detection reported by the assay manufacturers were relatively high: 0.1 &#x03BC;g/L for PCT-W and PCT-G, and 0.13 &#x03BC;g/L for PCT-S (<xref ref-type="bibr" rid="B21">21</xref>, <xref ref-type="bibr" rid="B22">22</xref>, <xref ref-type="bibr" rid="B24">24</xref>). Negative bias increased for PCT-G and PCT-S at low concentrations (&#x2264; 0.5 &#x03BC;g/L), which contributed to poorer agreement for LRTI cut-offs compared to sepsis cut-offs, due to the presence of additional low-concentration cut-offs in LRTI classifications. The PCT-W assay exhibited the highest proportional and constant bias values in the Passing-Bablok regression for concentrations ranging from the limit of quantification (LoQ) to 2 &#x03BC;g/L, with values of &#x2212;33.7% and 0.076 &#x03BC;g/L, respectively. Surprisingly, despite these biases, the agreement of PCT-W with the PCT-KR assay was the highest among all assays for LRTI diagnostic cut-offs. Cut-offs used for diagnosing and managing LRTI and sepsis are particularly stringent for the low-range performance of assays. Therefore, a thorough assessment of assay performance must include a close examination of how assays perform with low concentration samples. Regression and Bland-Altman bias plots were instrumental in this evaluation. Both the PCT-G and PCT-S assays exhibited increasingly negative bias values below the 0.5 &#x03BC;g/L cut-off. This bias resulted in the classification of samples into lower concentration categories compared to the predicate assay, leading to potential underestimation of sample concentrations and, consequently, the risk of under diagnosis of infections and inappropriate antibiotic use, especially for LRTI. Moreover, the specificity and sensitivity of PCT-W, PCT-G and PCT-S comparison demonstrated in <xref ref-type="supplementary-material" rid="TS1">Supplementary Table 1</xref>, indicated that there were specificity and sensitivity variation in those three assays compared to the standard PCT-KR. And the ROC curves to evaluate sensitivity and specificity at critical cut-offs (e.g., 0.15 &#x03BC;g/L, 0.25 &#x03BC;g/L, 0.5 &#x03BC;g/L) is demonstrated at <xref ref-type="supplementary-material" rid="FS1">Supplementary Figure 1</xref>.</p>
<p>In contrast, the PCT-W assay displayed a wide range of bias values, including both high negative and positive biases below the 0.5 &#x03BC;g/L cut-off. This variability led to the misclassification of samples into both higher and lower concentration ranges around the 0.25 &#x03BC;g/L cut-off, which could adversely affect patient management. Above the 0.5 &#x03BC;g/L cut-off, PCT-W showed an increase in negative bias, leading to further misclassification of samples due to underestimated concentrations. Similar misclassification issues have been reported by Li et al. (<xref ref-type="bibr" rid="B26">26</xref>), who compared plasma samples using the Roche Elecsys B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S PCT assay. Discrepancies between our findings and Li et al. (<xref ref-type="bibr" rid="B26">26</xref>) may stem from matrix differences (serum vs. plasma) and platform-specific antibody epitope recognition, particularly for PCT-G. When using B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S PCT algorithms, this underestimation could lead to under-diagnosis and unnecessary discontinuation of antibiotics.</p>
<p>Additionally, the total laboratory imprecision for low concentrations (&#x223C;0.25 &#x03BC;g/L) was significantly higher for these assays compared to the PCT-KR assay (4.64% for PCT-KR versus 8.38% to 15.67% for the other assays). In conclusion, the analytical performance of the assays at low concentrations compromised their effectiveness for sepsis and LRTI cut-offs, potentially impacting clinical accuracy and safety. Publications discussing the performance of the assays compared in this study are limited, restricting direct comparisons. One study evaluates the PCT-W assay using whole blood with a very small sample size, making comparisons difficult (<xref ref-type="bibr" rid="B27">27</xref>). Another publication compares plasma samples tested with Roche Elecsys B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S PCT, PCT-W, and PCT-G, but the reader instruments used in that study differ from those in the present study. This previous work employed Kappa coefficients for single cut-off classifications, reporting high agreement values for the 0.5 &#x03BC;g/L cut-off (PCT-W Kc = 0.8 and PCT-G Kc = 0.88), while PCT-G showed only moderate agreement at the 0.25 &#x03BC;g/L cut-off (PCT-W Kc = 0.8 and PCT-G Kc = 0.49) (<xref ref-type="bibr" rid="B26">26</xref>).</p>
<p>A multicenter study testing plasma with the PCT-S assay reported a high proportional bias (+51%) and a negative constant bias (&#x2212;0.1 &#x03BC;g/L) compared to the PCT-KR. The percent agreement values for patient classifications at specific cut-offs were higher than those in the present study: 0.10 &#x03BC;g/L (96% vs. 92%), 0.25 &#x03BC;g/L (96% vs. 92%), 0.5 &#x03BC;g/L (93% vs. 97%), and 2.0 &#x03BC;g/L (96% vs. 99%). Unfortunately, Kappa coefficients were not reported in this study, and it did not use serum samples, complicating comparisons (<xref ref-type="bibr" rid="B28">28</xref>). Another study with a small sample size of 40 serum samples found very low compliance rates for the PCT-S assay at LRTI cut-offs (&#x003C; 0.10 &#x03BC;g/L: 0%; &#x2265; 0.1 &#x03BC;g/L to &#x003C; 0.25 &#x03BC;g/L: 40%; &#x2265; 0.25 &#x03BC;g/L to &#x2264; 0.5 &#x03BC;g/L: 14.29%; &#x003E; 0.5 &#x03BC;g/L: 100%), using the Roche Elecsys B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S PCT as the reference assay (<xref ref-type="bibr" rid="B29">29</xref>).</p>
<sec id="S4.SS1">
<title>Limitations</title>
<p>This study is limited by its single-center design, evaluation of only three assays, and absence of longitudinal PCT monitoring for algorithm validation.</p>
</sec>
</sec>
<sec id="S5" sec-type="conclusion">
<title>Conclusion</title>
<p>All assays (PCT-W, PCT-G, and PCT-S) demonstrated some level of classification agreement with the PCT-KR reference assay for both sepsis and LRTI cut-offs. However, issues with recovery and poor precision around the 0.5 &#x03BC;g/L cut-off were noted for the PCT-S assay. The PCT-W and PCT-G assays revealed discrepancies with the reference in terms of recovery, imprecision, and linearity. Additionally, all assays showed increased individual sample bias at low concentrations. Underestimation of PCT at 0.25 &#x03BC;g/L (e.g., PCT-G bias: &#x2212;33%) could lead to delayed antibiotic initiation in 15&#x2013;20% of LRTI cases, as per Schuetz et al. (<xref ref-type="bibr" rid="B30">30</xref>). Conversely, overestimation (e.g., PCT-W bias: +18%) may result in unnecessary antibiotic prescriptions, increasing antimicrobial resistance risks. Therefore, the analytical performance of PCT-W, PCT-G, and PCT-S around the low-end cut-offs for LRTI and sepsis was found to be inadequate for accurate diagnosis and management.</p>
<p>In summary, despite showing classification agreement with the reference assay, the suitability of these assays for use with B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S PCT algorithms is compromised by various analytical performance issues. This raises concerns about the accuracy and safety of the evaluated assays. Further investigation is needed to assess their performance in clinical settings and to explore their diagnostic accuracy and clinical impact.</p>
</sec>
</body>
<back>
<sec id="S6" sec-type="data-availability">
<title>Data availability statement</title>
<p>The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.</p>
</sec>
<sec id="S7" sec-type="ethics-statement">
<title>Ethics statement</title>
<p>Ethical approval was not required for the studies on humans in accordance with the local legislation and institutional requirements because only commercially available established cell lines were used.</p>
</sec>
<sec id="S8" sec-type="author-contributions">
<title>Author contributions</title>
<p>RH: Writing &#x2013; original draft, Writing &#x2013; review and editing. XS: Writing &#x2013; original draft, Writing &#x2013; review and editing. LS: Data curation, Writing &#x2013; review and editing. TZ: Formal Analysis, Writing &#x2013; review and editing. JW: Investigation, Methodology, Writing &#x2013; original draft, Writing &#x2013; review and editing. QH: Investigation, Methodology, Project administration, Validation, Writing &#x2013; original draft, Writing &#x2013; review and editing.</p>
</sec>
<sec id="S9" sec-type="funding-information">
<title>Funding</title>
<p>The authors declare that no financial support was received for the research and/or publication of this article.</p>
</sec>
<sec id="S10" sec-type="COI-statement">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec id="S11" sec-type="disclaimer">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<sec id="S12" sec-type="supplementary-material">
<title>Supplementary material</title>
<p>The Supplementary Material for this article can be found online at: <ext-link ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/fmed.2025.1487557/full#supplementary-material">https://www.frontiersin.org/articles/10.3389/fmed.2025.1487557/full#supplementary-material</ext-link></p>
<supplementary-material xlink:href="Table_1.docx" id="TS1" mimetype="application/vnd.openxmlformats-officedocument.wordprocessingml.document" xmlns:xlink="http://www.w3.org/1999/xlink"/>
<supplementary-material xlink:href="Image_1.jpeg" id="FS1" mimetype="image/jpeg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
</sec>
<ref-list>
<title>References</title>
<ref id="B1"><label>1.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Becker</surname> <given-names>K</given-names></name> <name><surname>Snider</surname> <given-names>R</given-names></name> <name><surname>Nylen</surname> <given-names>E</given-names></name></person-group>. <article-title>Procalcitonin in sepsis and systemic inflammation: a harmful biomarker and a therapeutic target.</article-title> <source><italic>Br J Pharmacol.</italic></source> (<year>2010</year>) <volume>159</volume>:<fpage>253</fpage>&#x2013;<lpage>64</lpage>. <pub-id pub-id-type="doi">10.1111/j.1476-5381.2009.00433.x</pub-id> <pub-id pub-id-type="pmid">20002097</pub-id></citation></ref>
<ref id="B2"><label>2.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Meisner</surname> <given-names>M</given-names></name></person-group>. <article-title>Update on procalcitonin measurements.</article-title> <source><italic>Ann Lab Med.</italic></source> (<year>2014</year>) <volume>34</volume>:<fpage>263</fpage>&#x2013;<lpage>73</lpage>. <pub-id pub-id-type="doi">10.3343/alm.2014.34.4.263</pub-id> <pub-id pub-id-type="pmid">24982830</pub-id></citation></ref>
<ref id="B3"><label>3.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Meisner</surname> <given-names>M</given-names></name></person-group>. <article-title>Procalcitonin: Experience with a new diagnostic tool for bacterial infection and systemic inflammation.</article-title> <source><italic>Lab Med.</italic></source> (<year>1999</year>) <volume>23</volume>:<fpage>233</fpage>&#x2013;<lpage>72</lpage>. <pub-id pub-id-type="doi">10.1186/s13054-016-1208-6</pub-id> <pub-id pub-id-type="pmid">27885969</pub-id></citation></ref>
<ref id="B4"><label>4.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dandona</surname> <given-names>P</given-names></name> <name><surname>Nix</surname> <given-names>D</given-names></name> <name><surname>Wilson</surname> <given-names>M</given-names></name> <name><surname>Aljada</surname> <given-names>A</given-names></name> <name><surname>Love</surname> <given-names>J</given-names></name> <name><surname>Assicot</surname> <given-names>M</given-names></name><etal/></person-group> <article-title>Procalcitonin increase after endotoxin injection in normal subjects.</article-title> <source><italic>J Clin Endocrinol Metab.</italic></source> (<year>1994</year>) <volume>79</volume>:<fpage>1605</fpage>&#x2013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1210/jcem.79.6.7989463</pub-id> <pub-id pub-id-type="pmid">7989463</pub-id></citation></ref>
<ref id="B5"><label>5.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Schuetz</surname> <given-names>P</given-names></name></person-group>. <article-title>How to best use procalcitonin to diagnose infections and manage antibiotic treatment.</article-title> <source><italic>Clin Chem Lab Med.</italic></source> (<year>2022</year>) <volume>61</volume>:<fpage>822</fpage>&#x2013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1515/cclm-2022-1072</pub-id> <pub-id pub-id-type="pmid">36317790</pub-id></citation></ref>
<ref id="B6"><label>6.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Schuetz</surname> <given-names>P</given-names></name> <name><surname>Raad</surname> <given-names>I</given-names></name> <name><surname>Amin</surname> <given-names>D</given-names></name></person-group>. <article-title>Using procalcitonin-guided algorithms to improve antimicrobial therapy in ICU patients with respiratory infections and sepsis.</article-title> <source><italic>Curr Opin Crit Care.</italic></source> (<year>2013</year>) <volume>19</volume>:<fpage>453</fpage>&#x2013;<lpage>60</lpage>. <pub-id pub-id-type="doi">10.1097/MCC.0b013e328363bd38</pub-id> <pub-id pub-id-type="pmid">23817026</pub-id></citation></ref>
<ref id="B7"><label>7.</label><citation citation-type="journal"><collab>Who Strategic Advisory Group of Experts on In Vitro Diagnostics.</collab> <source><italic>The selection and use of essential in vitro diagnostics: report of the third meeting of the WHO Strategic Advisory Group of Experts on In Vitro Diagnostics, 2020.</italic></source> <publisher-loc>Geneva</publisher-loc>: <publisher-name>WHO</publisher-name> (<year>2021</year>).</citation></ref>
<ref id="B8"><label>8.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Evans</surname> <given-names>L</given-names></name> <name><surname>Rhodes</surname> <given-names>A</given-names></name> <name><surname>Alhazzani</surname> <given-names>W</given-names></name> <name><surname>Antonelli</surname> <given-names>M</given-names></name> <name><surname>Coopersmith</surname> <given-names>C</given-names></name> <name><surname>French</surname> <given-names>C</given-names></name><etal/></person-group> <article-title>Surviving sepsis campaign: International guidelines for management of sepsis and septic shock 2021.</article-title> <source><italic>Crit Care Med.</italic></source> (<year>2021</year>) <volume>49</volume>:<fpage>1063</fpage>&#x2013;<lpage>143</lpage>. <pub-id pub-id-type="doi">10.1007/s00134-021-06506-y</pub-id> <pub-id pub-id-type="pmid">34599691</pub-id></citation></ref>
<ref id="B9"><label>9.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chambliss</surname> <given-names>A</given-names></name> <name><surname>Patel</surname> <given-names>K</given-names></name> <name><surname>Col&#x00F3;n-Franco</surname> <given-names>J</given-names></name> <name><surname>Hayden</surname> <given-names>J</given-names></name> <name><surname>Katz</surname> <given-names>S</given-names></name> <name><surname>Minejima</surname> <given-names>E</given-names></name><etal/></person-group> <article-title>AACC guidance document on the clinical use of procalcitonin.</article-title> <source><italic>J Appl Lab Med.</italic></source> (<year>2023</year>) <volume>8</volume>:<fpage>598</fpage>&#x2013;<lpage>634</lpage>. <pub-id pub-id-type="doi">10.1093/jalm/jfad007</pub-id> <pub-id pub-id-type="pmid">37140163</pub-id></citation></ref>
<ref id="B10"><label>10.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lee</surname> <given-names>C</given-names></name> <name><surname>Kwa</surname> <given-names>A</given-names></name> <name><surname>Apisarnthanarak</surname> <given-names>A</given-names></name> <name><surname>Feng</surname> <given-names>J</given-names></name> <name><surname>Gluck</surname> <given-names>E</given-names></name> <name><surname>Ito</surname> <given-names>A</given-names></name><etal/></person-group> <article-title>Procalcitonin (PCT)-guided antibiotic stewardship in Asia-Pacific countries: Adaptation based on an expert consensus meeting.</article-title> <source><italic>Clin Chem Lab Med.</italic></source> (<year>2020</year>) <volume>58</volume>:<fpage>1983</fpage>&#x2013;<lpage>91</lpage>. <pub-id pub-id-type="doi">10.1515/cclm-2019-1122</pub-id> <pub-id pub-id-type="pmid">31926074</pub-id></citation></ref>
<ref id="B11"><label>11.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Schuetz</surname> <given-names>P</given-names></name> <name><surname>Beishuizen</surname> <given-names>A</given-names></name> <name><surname>Broyles</surname> <given-names>M</given-names></name> <name><surname>Ferrer</surname> <given-names>R</given-names></name> <name><surname>Gavazzi</surname> <given-names>G</given-names></name> <name><surname>Gluck</surname> <given-names>E</given-names></name><etal/></person-group> <article-title>Procalcitonin (PCT)-guided antibiotic stewardship: An international experts consensus on optimized clinical use.</article-title> <source><italic>Clin Chem Lab Med.</italic></source> (<year>2019</year>) <volume>57</volume>:<fpage>1308</fpage>&#x2013;<lpage>18</lpage>. <pub-id pub-id-type="doi">10.1515/cclm-2018-1181</pub-id> <pub-id pub-id-type="pmid">30721141</pub-id></citation></ref>
<ref id="B12"><label>12.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wang</surname> <given-names>Z</given-names></name></person-group>. <article-title>Expert consensus on the emergency clinical application of procalcitonin (PCT).</article-title> <source><italic>Chin J Emerg Med.</italic></source> (<year>2012</year>) <volume>21</volume>:<fpage>944</fpage>&#x2013;<lpage>51</lpage>. <pub-id pub-id-type="doi">10.3760/cma.j.issn.1671-0282.2012.09.004</pub-id> <pub-id pub-id-type="pmid">30704229</pub-id></citation></ref>
<ref id="B13"><label>13.</label><citation citation-type="journal"><collab>Chinese Society of Critical Care Medicine.</collab> <article-title>Guidelines for the treatment of severe sepsis/septic shock in China (2014).</article-title> <source><italic>Chin J Intern Med.</italic></source> (<year>2015</year>) <volume>54</volume>:<fpage>557-581</fpage>. <pub-id pub-id-type="doi">10.3760/cma.j.issn.0578-1426.2015.06.021</pub-id> <pub-id pub-id-type="pmid">30704229</pub-id></citation></ref>
<ref id="B14"><label>14.</label><citation citation-type="journal"><collab>Infectious Diseases Committee of China Medical Education Association.</collab> <article-title>Expert consensus on procalcitonin guiding the rational clinical application of antibacterial drugs.</article-title> <source><italic>Chin Med J</italic></source> (<year>2020</year>) <volume>100</volume>:<fpage>2813</fpage>&#x2013;<lpage>21</lpage>. <pub-id pub-id-type="doi">10.3760/10.3760/cma.j.cn112137-20200714-02112</pub-id> <pub-id pub-id-type="pmid">34648165</pub-id></citation></ref>
<ref id="B15"><label>15.</label><citation citation-type="journal"><collab>China Medical Education Association Infectious Disease Professional Committee, Emergency Physician Branch of Chinese Medical Doctor Association.</collab> <article-title>Expert consensus on diagnosis and treatment of adult community-acquired pneumonia in emergency departments.</article-title> <source><italic>Chin J Emergency Med.</italic></source> (<year>2015</year>) <volume>24</volume>:<fpage>1324</fpage>&#x2013;<lpage>44</lpage>. <pub-id pub-id-type="doi">10.3969/j.issn.1002-1949.2015.12.001</pub-id></citation></ref>
<ref id="B16"><label>16.</label><citation citation-type="journal"><collab>Infectious Diseases Professional Committee of China Medical Education Association.</collab> <article-title>Expert consensus on the interpretation of clinical significance of infection-related biomarkers.</article-title> <source><italic>Chin J Tuberculosis Respir Dis.</italic></source> (<year>2017</year>) <volume>40</volume>:<fpage>243</fpage>&#x2013;<lpage>57</lpage>. <pub-id pub-id-type="doi">10.3760/cma.j.issn.1001-0939.2017.04.001</pub-id> <pub-id pub-id-type="pmid">30704229</pub-id></citation></ref>
<ref id="B17"><label>17.</label><citation citation-type="journal"><collab>Expert Consensus Group on the Application of Procalcitonin in the Graded Management of Adult Lower Respiratory Tract Infectious Diseases.</collab> <article-title>Expert consensus on the application of procalcitonin in the graded management of adult lower respiratory tract infectious diseases.</article-title> <source><italic>Chin J Emergency Med.</italic></source> (<year>2021</year>) <volume>30</volume>:<fpage>393</fpage>&#x2013;<lpage>401</lpage>. <pub-id pub-id-type="doi">10.3760/cma.j.issn.1671-0282.2021.04.004</pub-id> <pub-id pub-id-type="pmid">30704229</pub-id></citation></ref>
<ref id="B18"><label>18.</label><citation citation-type="journal"><collab>Hospital Infection Management and Control Committee of Chinese Medical Doctor Association.</collab> <article-title>Expert consensus on the clinical application of procalcitonin in pediatric infectious diseases.</article-title> <source><italic>Chin J Pediatr.</italic></source> (<year>2019</year>) <volume>57</volume>:<fpage>9</fpage>&#x2013;<lpage>15</lpage>. <pub-id pub-id-type="doi">10.3760/cma.j.issn.0578-1310.2019.01.002</pub-id> <pub-id pub-id-type="pmid">30704229</pub-id></citation></ref>
<ref id="B19"><label>19.</label><citation citation-type="journal"><collab>Expert Consensus Group on the Clinical Application of Procalcitonin in Children with Lower Respiratory Tract Infections.</collab> <article-title>Expert consensus on the clinical application of procalcitonin in children with lower respiratory tract infections.</article-title> <source><italic>Chin J Emergency Med.</italic></source> (<year>2022</year>) <volume>31</volume>:<fpage>1578</fpage>&#x2013;<lpage>87</lpage>. <pub-id pub-id-type="doi">10.3760/cma.j.issn.1671-0282.2022.12.002</pub-id> <pub-id pub-id-type="pmid">30704229</pub-id></citation></ref>
<ref id="B20"><label>20.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zeng</surname> <given-names>J</given-names></name> <name><surname>Zhang</surname> <given-names>CB</given-names></name></person-group>. <article-title>[Current status of the application of point-of-care testing in serum procalcitonin].</article-title> <source><italic>Chin J Lab Med.</italic></source> (<year>2021</year>) <volume>44</volume>:<fpage>790</fpage>&#x2013;<lpage>3</lpage>. <pub-id pub-id-type="doi">10.3760/cma.j.issn.1671-0282.2022.12.002</pub-id> <pub-id pub-id-type="pmid">30704229</pub-id></citation></ref>
<ref id="B21"><label>21.</label><citation citation-type="journal"><collab>Guangzhou Wondfo Biotech.</collab> <source><italic>Instructions for use finecare procalcitonin (PCT) assay reagents (Rel 20180129).</italic></source> <publisher-loc>Guangzhou</publisher-loc>: <publisher-name>Guangzhou Wondfo Biotech</publisher-name> (<year>2017</year>).</citation></ref>
<ref id="B22"><label>22.</label><citation citation-type="journal"><collab>Getein Biotech.</collab> <source><italic>Instructions for use procalcitonin assay kit (20162401534).</italic></source> <publisher-loc>Nianjing</publisher-loc>: <publisher-name>Getein Biotech</publisher-name> (<year>2017</year>).</citation></ref>
<ref id="B23"><label>23.</label><citation citation-type="journal"><collab>B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S GmbH.</collab> <source><italic>Instructions for use B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S PCT sensitive Kryptor (03CN).</italic></source> <publisher-loc>Hennigsdorf</publisher-loc>: <publisher-name>B&#x22C5;R&#x22C5;A&#x22C5;H&#x22C5;M&#x22C5;S GmbH</publisher-name> (<year>2022</year>).</citation></ref>
<ref id="B24"><label>24.</label><citation citation-type="journal"><collab>Shenzhen New Industries Biomedical Engineering.</collab> <source><italic>Instructions for use procalcitonin assay kit (068PCT IFU-V6.30-en-US).</italic></source> <publisher-loc>Shenzhen</publisher-loc>: <publisher-name>Shenzhen New Industries Biomedical Engineering</publisher-name> (<year>2015</year>).</citation></ref>
<ref id="B25"><label>25.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Landis</surname> <given-names>J</given-names></name> <name><surname>Koch</surname> <given-names>G</given-names></name></person-group>. <article-title>The measurement of observer agreement for categorical data.</article-title> <source><italic>Biometrics.</italic></source> (<year>1977</year>) <volume>33</volume>:<fpage>159</fpage>&#x2013;<lpage>74</lpage>. <pub-id pub-id-type="doi">10.2307/2529310</pub-id></citation></ref>
<ref id="B26"><label>26.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Li</surname> <given-names>C</given-names></name> <name><surname>Huang</surname> <given-names>Y</given-names></name> <name><surname>Xu</surname> <given-names>Y</given-names></name></person-group>. <article-title>Determining procalcitonin at point-of-care; A method comparison study of four commercial PCT assays.</article-title> <source><italic>Pract Lab Med.</italic></source> (<year>2021</year>) <volume>25</volume>:<fpage>e00214</fpage>. <pub-id pub-id-type="doi">10.1016/j.plabm.2021.e00214</pub-id> <pub-id pub-id-type="pmid">33912643</pub-id></citation></ref>
<ref id="B27"><label>27.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Aizuddin</surname> <given-names>M</given-names></name> <name><surname>Zulfakar</surname> <given-names>M</given-names></name> <name><surname>Kamalrujan</surname> <given-names>S</given-names></name></person-group>. <article-title>Evaluation of agreement between point-of-care and laboratory automated immunoassay in procalcitonin measurement among critically ill patients.</article-title> <source><italic>Pain Intensive Care.</italic></source> (<year>2023</year>) <volume>27</volume>:<fpage>470</fpage>&#x2013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.35975/apic.v27i4.2277</pub-id></citation></ref>
<ref id="B28"><label>28.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lippi</surname> <given-names>G</given-names></name> <name><surname>Salvagno</surname> <given-names>G</given-names></name> <name><surname>Gelati</surname> <given-names>M</given-names></name></person-group>. <article-title>Two-center comparison of 10 fully-automated commercial procalcitonin (PCT) immunoassays.</article-title> <source><italic>Clin Chem Lab Med.</italic></source> (<year>2019</year>) <volume>58</volume>:<fpage>77</fpage>&#x2013;<lpage>84</lpage>. <pub-id pub-id-type="doi">10.1515/cclm-2019-0888</pub-id> <pub-id pub-id-type="pmid">31539351</pub-id></citation></ref>
<ref id="B29"><label>29.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yang</surname> <given-names>L</given-names></name> <name><surname>Wang</surname> <given-names>L</given-names></name> <name><surname>Gong</surname> <given-names>Y</given-names></name> <name><surname>Shi</surname> <given-names>W</given-names></name> <name><surname>An</surname> <given-names>X</given-names></name> <name><surname>Zheng</surname> <given-names>H</given-names></name></person-group>. <article-title>Performance verification of a new domestic chemiluminescence detection system.</article-title> <source><italic>Ann Transl Med.</italic></source> (<year>2020</year>) <volume>8</volume>:<fpage>1454</fpage>. <pub-id pub-id-type="doi">10.21037/atm-20-7047</pub-id> <pub-id pub-id-type="pmid">33313199</pub-id></citation></ref>
<ref id="B30"><label>30.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Schuetz</surname> <given-names>P</given-names></name> <name><surname>Wirz</surname> <given-names>Y</given-names></name> <name><surname>Sager</surname> <given-names>R</given-names></name> <name><surname>Christ-Crain</surname> <given-names>M</given-names></name> <name><surname>Stolz</surname> <given-names>D</given-names></name> <name><surname>Tamm</surname> <given-names>M</given-names></name><etal/></person-group> <article-title>Effect of procalcitonin-guided antibiotic treatment on mortality in acute respiratory infections: A meta-analysis.</article-title> <source><italic>Clin Chem Lab Med.</italic></source> (<year>2019</year>) <volume>57</volume>:<fpage>1308</fpage>&#x2013;<lpage>18</lpage>. <pub-id pub-id-type="doi">10.1016/S1473-3099(17)30592-3</pub-id> <pub-id pub-id-type="pmid">29037960</pub-id></citation></ref>
</ref-list>
</back>
</article>