<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Med.</journal-id>
<journal-title>Frontiers in Medicine</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Med.</abbrev-journal-title>
<issn pub-type="epub">2296-858X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fmed.2023.1241824</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Medicine</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Accuracy of the FY-L formula in calculating intraocular lens power after small-incision lenticule extraction</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" equal-contrib="yes">
<name><surname>Hu</surname> <given-names>Yingfeng</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="author-notes" rid="fn001"><sup>&#x02020;</sup></xref>
</contrib>
<contrib contrib-type="author" equal-contrib="yes">
<name><surname>Lin</surname> <given-names>Liqun</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="author-notes" rid="fn001"><sup>&#x02020;</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Zeng</surname> <given-names>Danqi</given-names></name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Wang</surname> <given-names>Yan</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Zhang</surname> <given-names>Rong</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Zhang</surname> <given-names>Zhe</given-names></name>
<xref ref-type="aff" rid="aff4"><sup>4</sup></xref>
<xref ref-type="aff" rid="aff5"><sup>5</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/1826487/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Wang</surname> <given-names>Zheng</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name><surname>Zhang</surname> <given-names>Guangbin</given-names></name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<xref ref-type="corresp" rid="c001"><sup>&#x0002A;</sup></xref>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name><surname>Ye</surname> <given-names>Xiangyu</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<xref ref-type="corresp" rid="c002"><sup>&#x0002A;</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/1948911/overview"/>
</contrib>
</contrib-group>
<aff id="aff1"><sup>1</sup><institution>Fuzhou Eye Hospital, Fuzhou</institution>, <addr-line>Fujian</addr-line>, <country>China</country></aff>
<aff id="aff2"><sup>2</sup><institution>Xianyou County General Hospital, Putian</institution>, <addr-line>Fujian</addr-line>, <country>China</country></aff>
<aff id="aff3"><sup>3</sup><institution>Xiamen Eye Center, Xiamen University, Xiamen</institution>, <addr-line>Fujian</addr-line>, <country>China</country></aff>
<aff id="aff4"><sup>4</sup><institution>Shenzhen Eye Hospital, Jinan University, Shenzhen</institution>, <addr-line>Guangdong</addr-line>, <country>China</country></aff>
<aff id="aff5"><sup>5</sup><institution>Shenzhen Eye Institute, Shenzhen</institution>, <addr-line>Guangdong</addr-line>, <country>China</country></aff>
<author-notes>
<fn fn-type="edited-by"><p>Edited by: Jin Yang, Fudan University, China</p></fn>
<fn fn-type="edited-by"><p>Reviewed by: Li Wang, Baylor College of Medicine, United States; Hung-Yuan Lin, Universal Eye Center, Taiwan; Lixia Luo, Sun Yat-sen University, China</p></fn>

<corresp id="c001">&#x0002A;Correspondence: Guangbin Zhang <email>386975604&#x00040;qq.com</email></corresp>
<corresp id="c002">Xiangyu Ye <email>yexiangyu2023&#x00040;163.com</email></corresp>
<fn fn-type="equal" id="fn001"><p>&#x02020;These authors have contributed equally to this work and share first authorship</p></fn></author-notes>
<pub-date pub-type="epub">
<day>24</day>
<month>08</month>
<year>2023</year>
</pub-date>
<pub-date pub-type="collection">
<year>2023</year>
</pub-date>
<volume>10</volume>
<elocation-id>1241824</elocation-id>
<history>
<date date-type="received">
<day>17</day>
<month>06</month>
<year>2023</year>
</date>
<date date-type="accepted">
<day>01</day>
<month>08</month>
<year>2023</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x000A9; 2023 Hu, Lin, Zeng, Wang, Zhang, Zhang, Wang, Zhang and Ye.</copyright-statement>
<copyright-year>2023</copyright-year>
<copyright-holder>Hu, Lin, Zeng, Wang, Zhang, Zhang, Wang, Zhang and Ye</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license> </permissions>
<abstract>
<sec>
<title>Purpose</title>
<p>The study aimed to assess the accuracy of the FY-L formula in calculating intraocular lens (IOL) power after small-incision lenticule extraction (SMILE).</p></sec>
<sec>
<title>Methods</title>
<p>For the post-SMILE IOL calculation of the same eye, the IOL power targeting the pre-SMILE eyes&#x00027; lowest myopic refractive error was used. The FY-L formula, the Emmetropia Verifying Optical Formula (EVO-L), the Barrett True-K no history, and the Shammas-L, respectively, were used to calculate the predicted refractive error of target IOL power. A comparison was made between the change in spherical equivalent induced by SMILE (SMILE-Dif) and the variance between IOL-Dif (IOL-Induced Refractive Error) before and after SMILE. The prediction error (PE) was defined as SMILE-Dif minus IOL-Dif. The proportion of eyes with PEs within &#x000B1;0.25 D, &#x000B1;0.50 D, &#x000B1;0.75 D, and &#x000B1;1.00 D, the numerical and absolute prediction errors (PEs and AEs), and the median absolute error (MedAE) were compared.</p></sec>
<sec>
<title>Results</title>
<p>In total, 80 eyes from 42 patients who underwent SMILE were included in the study. The FY-L formula generated the sample&#x00027;s lowest mean PE (0.06 &#x000B1; 0.76 D), MAE (0.58 &#x000B1; 0.50 D), and MedAE (0.47 D), respectively. The PEs in &#x000B1;0.25 D, &#x000B1;0.50 D, &#x000B1;0.75 D, and &#x000B1;1.00 D comprised 28.8%, 46.3%, 70.0%, and 87.5%, respectively, for the FY-L formula. Compared to other formulas, the FY-L formula produced the highest value with PEs for the percentage of eyes in &#x000B1;0.50 D, &#x000B1;0.75 D, and &#x000B1;1.00 D.</p></sec>
<sec>
<title>Conclusion</title>
<p>This study demonstrates that the FY-L formula provides satisfactory outcomes in estimating the IOL power in the eyes after SMILE.</p></sec></abstract>
<kwd-group>
<kwd>intraocular lens power calculation</kwd>
<kwd>FY-L formula</kwd>
<kwd>accuracy</kwd>
<kwd>theoretical model</kwd>
<kwd>small-incision lenticule extraction</kwd>
</kwd-group>
<counts>
<fig-count count="3"/>
<table-count count="2"/>
<equation-count count="0"/>
<ref-count count="30"/>
<page-count count="7"/>
<word-count count="5102"/>
</counts>
<custom-meta-wrap>
<custom-meta>
<meta-name>section-at-acceptance</meta-name>
<meta-value>Ophthalmology</meta-value>
</custom-meta>
</custom-meta-wrap>
</article-meta>
</front>
<body>
<sec sec-type="intro" id="s1">
<title>Introduction</title>
<p>The number of laser refractive procedures has significantly increased during the last three decades. Small incision lenticule extraction (SMILE), one of the most well-known and established keratorefractive treatments for the correction of myopia, has been used in more than five million surgeries worldwide (<xref ref-type="bibr" rid="B1">1</xref>). However, it is difficult to attain the intraocular lens (IOL) estimation specifications for these people while they are having cataract surgery. The two main reasons that IOL power calculations after refractive surgery went wrong were an inaccurate measurement of keratometry (K) value and incorrect predictions of effective lens position (ELP) (<xref ref-type="bibr" rid="B2">2</xref>, <xref ref-type="bibr" rid="B3">3</xref>). After the corneal refractive procedure, the cornea&#x00027;s anterior&#x02013;posterior surface relationship is changed (<xref ref-type="bibr" rid="B4">4</xref>, <xref ref-type="bibr" rid="B5">5</xref>). The predicted total corneal power based on the anterior corneal power could be erroneous when the standardized value (1.3375) for the refractive index of the cornea is applied (<xref ref-type="bibr" rid="B6">6</xref>, <xref ref-type="bibr" rid="B7">7</xref>). In order to predict the ELP, several IOL calculation formulas use corneal power values. Incorrect corneal refractive power leads to incorrect ELP.</p>
<p>To overcome these limitations, numerous theoretical and empirical strategies have been developed. Various methods, including Feiz/Mannis (<xref ref-type="bibr" rid="B7">7</xref>), clinical history (<xref ref-type="bibr" rid="B8">8</xref>), and the corneal bypass method (<xref ref-type="bibr" rid="B9">9</xref>), employ preoperative k and changes in manifest refraction to estimate corneal power. Aramberri (<xref ref-type="bibr" rid="B3">3</xref>) suggested using the double-K method to prevent the ELP-related IOL prediction error. Various methods that do not need preoperative information have been developed, including Barrett True-K no history, Shammas-L, EVO-L, and the American Society of Cataract and Refractive Surgery (ASCRS) average method (<xref ref-type="bibr" rid="B2">2</xref>, <xref ref-type="bibr" rid="B10">10</xref>, <xref ref-type="bibr" rid="B11">11</xref>). Some researchers found that the Barrett True-K appears to have a greater accuracy among these methods in eyes after myopic laser <italic>in situ</italic> keratomileusis (LASIK) or photorefractive keratectomy (PRK) (<xref ref-type="bibr" rid="B12">12</xref>&#x02013;<xref ref-type="bibr" rid="B14">14</xref>). A new no-history method named FY-L was developed for eyes that underwent LASIK or PRK, which utilizes the corrected keratometric value combined with an optimized ELP prediction method. In this study, the accuracy of various IOL power calculation formulas, including FY-L, Barrett True-K no history with and without the posterior corneal power, Emmetropia Verifying Optical Formula (EVO-L), and Shammas-L, was assessed in eyes with SMILE.</p></sec>
<sec sec-type="methods" id="s2">
<title>Methods</title>
<sec>
<title>Patients and surgery</title>
<p>This prospective study was consented to by the Fuzhou Eye Hospital (FZYKYY-KY-2023-007) and conformed to the Declaration of Helsinki. All patients provided written consent. In total, 80 eyes from 42 patients who underwent SMILE between September 2022 and December 2023 in Fuzhou Eye Hospital and Xiamen Eye Center Affiliated with Xiamen University were included in the study. The VisuMax femtosecond laser (Carl Zeiss Meditec AG) was used for the SMILE treatments, which were performed by experienced refractive surgeons.</p>
<p>The eligibility requirements for enrollment included refraction stability for 2 years, 20/20 corrected distance visual acuity, and successful SMILE surgeries with no complications that occurred during or after surgery. Exclusion criteria included corneal disease, severe dry eye, serious intraoperative or postoperative complications that would distort data on the final refractive outcome, ocular infection, any optical opacities or pathology shown after slit-lamp examination, prior intraocular surgery, corneal surgery, or ocular trauma.</p></sec>
<sec>
<title>Preoperative and postoperative measurements</title>
<p>Every patient underwent a complete ophthalmic examination before and after SMILE, including uncorrected distance visual acuity, slit-lamp examination, tonometry, fundoscopy, corrected distance visual acuity, and manifest and cycloplegic refraction. IOLMaster 700 (Carl Zeiss Jena, Germany) was employed to measure the following measurements: axial length (AL), anterior chamber depth (ACD), keratometry (K), lens thickness (LT), and white to white (WTW). Corneal topography and posterior corneal power were examined using the Pentacam (Oculus, Wetzlar, Germany). At least 3 months after the operation was completed, the postoperative examination was performed.</p></sec>
<sec>
<title>IOL power calculation</title>
<p>To emulate cataract surgery in post-SMILE eyes, a theoretical calculation model was presented. It is assumed that all patients are implanted with monofocal IOL (SN60WF, Alcon Laboratories, Inc.) with the following constants: for Haigis, a0 = 1.839, a1 = 0.4, and a2 = 0.1, and 118.9 for the other formulas. The Haigis formula was used for calculating the pre-SMILE IOL power. The post-SMILE IOL power was calculated using four methods, including the FY-L formula, the Barrett True-K no history formula, the EVO-L formula, and the Shammas-L formula, respectively. The Barrett True-K no history formula was calculated in two modes, including using the predicted corneal power of the posterior surface (PPCP) and the actual measured corneal power of the posterior surface (MPCP). For the post-SMILE IOL calculation of the same eye, the IOL power targeting the pre-SMILE eyes&#x00027; lowest myopic refractive error was used.</p>
<p>The FY-L formula used the Actual Ka &#x0002B; p method to modify the measured corneal power (<xref ref-type="bibr" rid="B15">15</xref>). The corneal power was calculated as follows: K<sub>corrected</sub> = 1.114 &#x000D7; (K<sub>flattest</sub> &#x0002B; K<sub>steepest</sub>)/2 &#x0002B; K<sub>posterior</sub>, where K<sub>flattest</sub> and K<sub>steepest</sub> were measured by the IOL master 700, and K<sub>posterior</sub> was measured by Pentacam.</p>
<p>To predict the ELP, the FY-L formula was based on the FY-IOL formula, which uses the ACD, anterior and posterior corneal power, LT, and AL for calculation.</p></sec>
<sec>
<title>Calculation of the prediction error</title>
<p>The evaluation was performed on the differences in the IOL-induced refractive error (IOL-Dif) before and after SMILE (<xref ref-type="bibr" rid="B16">16</xref>). For example, A &#x0002B;12.00 diopter (D)-IOL was selected to target postoperative refraction of &#x02212;0.20 D before SMILE. After SMILE, the same IOL was used to calculate the resulting target refraction (4.50 D). The IOL difference (IOL-Dif) would be 4.50 D- (&#x02212;0.20 D) = 4.70 D. The difference caused by the SMILE surgery in preoperative and postoperative manifest subjective refraction is defined as SMILE-Dif. IOL-Dif minus SMILE-Dif was used to define the prediction error (PE). Negative values show a myopic shift and positive values show a hyperopic shift. The proportion of eyes with PEs within &#x000B1;0.25 D, &#x000B1;0.50 D, &#x000B1;0.75 D, and &#x000B1;1.00 D, the numerical and absolute prediction errors (PEs and AEs), and the median absolute error (MedAE) were calculated for each formula to assess the predictive accuracy. In this study, we did not adjust the mean PE to zero for two reasons: (1) All patients were simulated with the same IOL implanted, and an optimized IOL constant was used for IOL calculations and (2) in the normal clinical scenario, the post-refractive patient has a relatively large range of refractive error, and optimization of IOL constants may not be very effective. The surgeons routinely use the optimized IOL constants from patients with normal cataracts and do not have specific optimized lens constants for eyes after refractive surgery for IOL calculations.</p></sec>
<sec>
<title>Statistics</title>
<p>Statistical analysis was performed using SPSS software (version 22.0, SPSS Inc., Chicago, USA). The normality of the data was checked using the Kolmogorov&#x02013;Smirnov test. A generalized estimating equation (GEE) procedure was used to adjust the correlation between the right and left eyes. Differences in PEs and AEs for all methods were compared by a GEE model and included Bonferroni multiple comparisons. The Cochran <italic>Q</italic>-test was used to compare the percentage of eyes with a PE within each interval. Any statistically significant difference found in Cochran&#x00027;s <italic>Q</italic> was determined using McNemar&#x00027;s test with Bonferroni adjustment. A <italic>P</italic>-value of &#x0003C; 0.05 was considered to be statistically significant.</p></sec></sec>
<sec sec-type="results" id="s3">
<title>Results</title>
<p><xref ref-type="table" rid="T1">Table 1</xref> sums up all the biometrics and demographics of the study population. The study comprised 80 eyes of 42 patients. The study contained 24 men and 18 women. The mean age was 23.54 &#x000B1; 4.03 years. The mean SE before SMILE was &#x02212;4.95 &#x000B1; 1.66 D. After SMILE, the mean SE was 0.04 &#x000B1; 0.58 D. The mean SMILE-Dif was 4.87 &#x000B1; 1.95 D. <xref ref-type="fig" rid="F1">Figures 1</xref>, <xref ref-type="fig" rid="F2">2</xref> show the distribution and quartile ranges of the PEs and the AEs for each formula, respectively. <xref ref-type="table" rid="T2">Table 2</xref> summarizes the mean PE, MedAE, MAE, and the percentages with PEs within &#x000B1;0.25 D, &#x000B1;0.50 D, &#x000B1;0.75 D, and &#x000B1;1.00 D in the 80 eyes retrospectively, while various formulas were used.</p>
<table-wrap position="float" id="T1">
<label>Table 1</label>
<caption><p>Data sample characteristics (<italic>n</italic> = 80).</p></caption> 
<table frame="box" rules="all">
<thead>
<tr style="background-color:&#x00023;919498;color:&#x00023;ffffff">
<th valign="top" align="left"><bold>Parameter</bold></th>
<th valign="top" align="center"><bold>Measurement before SMILE</bold></th>
<th valign="top" align="center"><bold>Measurement after SMILE</bold></th>
<th valign="top" align="center"><bold><italic>P</italic>-value</bold></th>
</tr>
</thead>
<tbody>
<tr style="background-color:#dee1e1">
<td valign="top" align="left" colspan="4"><bold>Sex (F/M)</bold></td>
</tr> <tr>
<td valign="top" align="left"><italic>n</italic></td>
<td/>
<td valign="top" align="center">18/24</td>
<td/>
</tr> <tr>
<td valign="top" align="left">(%)</td>
<td/>
<td valign="top" align="center">42.9%/57.1%</td>
<td/>
</tr> <tr style="background-color:#dee1e1">
<td valign="top" align="left" colspan="4"><bold>Eye (OD/OS)</bold></td>
</tr> <tr>
<td valign="top" align="left"><italic>n</italic></td>
<td/>
<td valign="top" align="center">40/40</td>
<td/>
</tr> <tr>
<td valign="top" align="left">(%)</td>
<td/>
<td valign="top" align="center">50%/50%</td>
<td/>
</tr> <tr style="background-color:#dee1e1">
<td valign="top" align="left" colspan="4"><bold>Age (y)</bold></td>
</tr> <tr>
<td valign="top" align="left">Mean &#x000B1; SD</td>
<td/>
<td valign="top" align="center">23.54 &#x000B1; 4.03</td>
<td/>
</tr> <tr>
<td valign="top" align="left">Range</td>
<td/>
<td valign="top" align="center">17, 33</td>
<td/>
</tr> <tr style="background-color:#dee1e1">
<td valign="top" align="left" colspan="4"><bold>Manifest refraction spherical equivalent (D)</bold></td>
</tr> <tr>
<td valign="top" align="left">Mean &#x000B1; SD</td>
<td valign="top" align="center">&#x02212;4.95 &#x000B1; 1.66</td>
<td valign="top" align="center">0.04 &#x000B1; 0.58</td>
<td valign="top" align="center">&#x0003C; 0.001</td>
</tr> <tr>
<td valign="top" align="left">Range</td>
<td valign="top" align="center">&#x02212;9, &#x02212;1.5</td>
<td valign="top" align="center">&#x02212;2.5, 1.25</td>
<td/>
</tr> <tr style="background-color:#dee1e1">
<td valign="top" align="left" colspan="4"><bold>Axial length (mm)</bold></td>
</tr> <tr>
<td valign="top" align="left">Mean &#x000B1; SD</td>
<td valign="top" align="center">25.50 &#x000B1; 1.06</td>
<td valign="top" align="center">25.37 &#x000B1; 1.05</td>
<td valign="top" align="center">&#x0003C; 0.001</td>
</tr> <tr>
<td valign="top" align="left">Range</td>
<td valign="top" align="center">23.28, 28.11</td>
<td valign="top" align="center">23.20, 27.84</td>
<td/>
</tr> <tr style="background-color:#dee1e1">
<td valign="top" align="left" colspan="4"><bold>Anterior chamber depth (mm)</bold></td>
</tr> <tr>
<td valign="top" align="left">Mean &#x000B1; SD</td>
<td valign="top" align="center">3.72 &#x000B1; 0.26</td>
<td valign="top" align="center">3.53 &#x000B1; 0.27</td>
<td valign="top" align="center">&#x0003C; 0.001</td>
</tr> <tr>
<td valign="top" align="left">Range</td>
<td valign="top" align="center">3.18, 4.33</td>
<td valign="top" align="center">3.18, 4.33</td>
<td/>
</tr> <tr style="background-color:#dee1e1">
<td valign="top" align="left" colspan="4"><bold>Lens thickness (mm)</bold></td>
</tr> <tr>
<td valign="top" align="left">Mean &#x000B1; SD</td>
<td valign="top" align="center">3.57 &#x000B1; 0.21</td>
<td valign="top" align="center">3.65 &#x000B1; 0.22</td>
<td valign="top" align="center">&#x0003C; 0.001</td>
</tr> <tr>
<td valign="top" align="left">Range</td>
<td valign="top" align="center">3.15, 4.01</td>
<td valign="top" align="center">2.98, 4.17</td>
<td/>
</tr> <tr style="background-color:#dee1e1">
<td valign="top" align="left" colspan="4"><bold>Mean keratometry (D)</bold></td>
</tr> <tr>
<td valign="top" align="left">Mean &#x000B1; SD</td>
<td valign="top" align="center">43.79 &#x000B1; 1.29</td>
<td valign="top" align="center">39.30 &#x000B1; 1.29</td>
<td valign="top" align="center">&#x0003C; 0.001</td>
</tr> <tr>
<td valign="top" align="left">Range</td>
<td valign="top" align="center">40.84, 46.41</td>
<td valign="top" align="center">35.87, 44.11</td>
<td/>
</tr> <tr style="background-color:#dee1e1">
<td valign="top" align="left" colspan="4"><bold>Mean posterior keratometry (D)</bold></td>
</tr> <tr>
<td valign="top" align="left">Mean &#x000B1; SD</td>
<td valign="top" align="center">&#x02212;6.34 &#x000B1; 0.20</td>
<td valign="top" align="center">&#x02212;6.33 &#x000B1; 0.21</td>
<td valign="top" align="center">0.083</td>
</tr>
<tr>
<td valign="top" align="left">Range</td>
<td valign="top" align="center">&#x02212;6.7, &#x02212;5.90</td>
<td valign="top" align="center">&#x02212;6.7, &#x02212;5.80</td>
<td/>
</tr>
</tbody>
</table>
<table-wrap-foot>
<p>F, female; M, male; IOL, intraocular lens; mm, millimeters; D, diopters; OD, right eye; OS, left eyes; SMILE, small-incision lenticule extraction.</p>
</table-wrap-foot>
</table-wrap>
<fig id="F1" position="float">
<label>Figure 1</label>
<caption><p>Distribution and quartile ranges of the PEs.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmed-10-1241824-g0001.tif"/>
</fig>
<fig id="F2" position="float">
<label>Figure 2</label>
<caption><p>Distribution and quartile ranges of the AEs.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmed-10-1241824-g0002.tif"/>
</fig>
<table-wrap position="float" id="T2">
<label>Table 2</label>
<caption><p>Mean prediction error, mean absolute prediction error, median of absolute prediction error, and percentage within a specific refractive error range.</p></caption> 
<table frame="box" rules="all">
<thead>
<tr style="background-color:&#x00023;919498;color:&#x00023;ffffff">
<th valign="top" align="left"><bold>IOL formula</bold></th>
<th valign="top" align="center"><bold>PE (D)</bold></th>
<th valign="top" align="center"><bold>MAE (D)</bold></th>
<th valign="top" align="center"><bold>MedAE (D)</bold></th>
<th valign="top" align="center"><bold>&#x000B1;0.25 D (%)</bold></th>
<th valign="top" align="center"><bold>&#x000B1;0.50 D (%)</bold></th>
<th valign="top" align="center"><bold>&#x000B1;0.75 D (%)</bold></th>
<th valign="top" align="center"><bold>&#x000B1;1 D (%)</bold></th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">FY-L</td>
<td valign="top" align="center">0.06 &#x000B1; 0.76</td>
<td valign="top" align="center">0.58 &#x000B1; 0.50</td>
<td valign="top" align="center">0.47</td>
<td valign="top" align="center">28.8%</td>
<td valign="top" align="center">46.3%</td>
<td valign="top" align="center">70.0%</td>
<td valign="top" align="center">87.5%</td>
</tr> <tr>
<td valign="top" align="left">Barrett True-k no history (MPCP)</td>
<td valign="top" align="center">0.36 &#x000B1; 0.76</td>
<td valign="top" align="center">0.64 &#x000B1; 0.51</td>
<td valign="top" align="center">0.55</td>
<td valign="top" align="center">30.0%</td>
<td valign="top" align="center">46.3%</td>
<td valign="top" align="center">62.5%</td>
<td valign="top" align="center">78.8%</td>
</tr> <tr>
<td valign="top" align="left">Barrett True-k no history (PPCP)</td>
<td valign="top" align="center">0.47 &#x000B1; 0.90</td>
<td valign="top" align="center">0.74 &#x000B1; 0.62</td>
<td valign="top" align="center">0.58</td>
<td valign="top" align="center">20.0%</td>
<td valign="top" align="center">42.5%</td>
<td valign="top" align="center">58.8%</td>
<td valign="top" align="center">70.0%</td>
</tr> <tr>
<td valign="top" align="left">EVO-L</td>
<td valign="top" align="center">0.85 &#x000B1; 0.82</td>
<td valign="top" align="center">0.93 &#x000B1; 0.64</td>
<td valign="top" align="center">0.92</td>
<td valign="top" align="center">18.8%</td>
<td valign="top" align="center">26.3%</td>
<td valign="top" align="center">36.3%</td>
<td valign="top" align="center">53.8%</td>
</tr> <tr>
<td valign="top" align="left">Shammas-L</td>
<td valign="top" align="center">&#x02212;0.91 &#x000B1; 0.77</td>
<td valign="top" align="center">1.04 &#x000B1; 0.67</td>
<td valign="top" align="center">0.98</td>
<td valign="top" align="center">13.8%</td>
<td valign="top" align="center">23.8%</td>
<td valign="top" align="center">40.0%</td>
<td valign="top" align="center">58.8%</td>
</tr>
<tr>
<td valign="top" align="left"><italic>P</italic>-value</td>
<td valign="top" align="center">&#x0003C; 0.001<xref ref-type="table-fn" rid="TN1"><sup>a</sup></xref></td>
<td valign="top" align="center">&#x0003C; 0.001<xref ref-type="table-fn" rid="TN2"><sup>b</sup></xref></td>
<td valign="top" align="center">n.s.</td>
<td valign="top" align="center">0.011<xref ref-type="table-fn" rid="TN3"><sup>c</sup></xref></td>
<td valign="top" align="center">&#x0003C; 0.001<xref ref-type="table-fn" rid="TN3"><sup>c</sup></xref></td>
<td valign="top" align="center">&#x0003C; 0.001<xref ref-type="table-fn" rid="TN3"><sup>c</sup></xref></td>
<td valign="top" align="center">&#x0003C; 0.001<xref ref-type="table-fn" rid="TN3"><sup>c</sup></xref></td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<p>FY-L, FY-L formula; Barrett True-k no history (PPCP), Barrett True-K no history formula without posterior corneal power; Barrett True-k no history (MPCP), Barrett True-K no history formula with posterior corneal power; EVO-L, EVO-L formula; Shammas-L, Shammas-L formula; D, diopters; MAE, mean absolute prediction error; MedAE, median absolute prediction error; PE, mean numerical prediction error.</p>
<fn id="TN1"><label>a</label><p>Difference among the PEs.</p></fn>
<fn id="TN2"><label>b</label><p>Difference among the MAEs.</p></fn>
<fn id="TN3"><label>c</label><p>Difference among the percentages of eyes within each PE.</p></fn>
</table-wrap-foot>
</table-wrap>
<p>The FY-L formula generated the sample&#x00027;s lowest PE (0.06 &#x000B1; 0.76 D) and MedAE (0.47D). The general difference between the PEs had statistical significance (<italic>P</italic> &#x0003C; 0.001), and the <italic>post-hoc</italic> analysis showed a statistical difference between all comparisons, with <italic>P</italic>-values of &#x0003C; 0.001, except <italic>P</italic> = 0.041 in Barrett True-K no history (MPCP) vs. the Barrett True-K no history (PPCP).</p>
<p>The average values of the AEs employing the FY-L formula were 0.58 &#x000B1; 0.50 D (range, 0.01&#x02013;2.43 D), 0.64 &#x000B1; 0.51 D (range, 0.01&#x02013;2.54 D) for the Barrett True-K no history (MPCP), 0.74 &#x000B1; 0.62 D (range, 0.00&#x02013;4.12 D) for the Barrett True-K no history (PPCP), 0.93 &#x000B1; 0.64 D (range, 0.01&#x02013;2.91 D) for the EVO-L formula, and 1.04 &#x000B1; 0.67 D (range, 0.00&#x02013;3.13 D) for Shammas-L formula. The GEE procedure found differences that were statistically significant between the AEs (<italic>P</italic> &#x0003C; 0.001). The posttest found statistical differences between FY-L vs. EVO-L and FY-L vs. Shammas-L, with <italic>P</italic>-values of &#x0003C; 0.001 and 0.001, respectively. The comparison of Barrett True-K no history (MPCP) with EVO-L and Shammas-L also showed statistical differences with <italic>P</italic>-values of &#x0003C; 0.001 and 0.013. Other statistically significant comparisons were between Barrett True-K no history (PPCP) vs. EVO-L and EVO-L vs. Shammas-L, with <italic>P-</italic>values of 0.001 and &#x0003C; 0.001. No differences were found in the rest of the comparisons.</p>
<p>The prediction errors within &#x000B1;0.25 D were 28.8%, 46.3% within &#x000B1;0.50 D, 70% within &#x000B1;0.75 D, and 87.5% within &#x000B1;1.00 D, respectively, for the FY-L formula. Compared the FY-L formula with other formulas, it produced the highest value for the proportion of PEs with ranges between &#x000B1;0.50 D and &#x000B1;0.75 D as well as &#x000B1;1.00 D (<xref ref-type="fig" rid="F3">Figure 3</xref>). The following comparisons of proportions within &#x000B1;0.25 D found statistical differences: FY-L vs. Shammas-L (<italic>P</italic> = 0.034), Barrett True-K no history (MPCP) vs. Barrett True-K no history (PPCP; <italic>P</italic> = 0.011), and Barrett True-K no history (MPCP) vs. Shammas-L (<italic>P</italic> = 0.028). Concerning the proportion of &#x000B1;0.5 D, the comparison of FY-L with Barrett True-K no history (PPCP), FY-L with EVO-L, and FY-L with Shammas-L showed statistical differences with <italic>P</italic>-values of 0.033, &#x0003C; 0.001, and &#x0003C; 0.001. There were statistically significant differences between Barrett True-K no history (MPCP) and EVO-L vs. Barrett True-K no history (MPCP) vs. Shammas-L, with both <italic>P</italic>-values of 0.001 for the comparison. Other statistically significant comparisons were between Barrett True-K no history (PPCP) vs. EVO-L and Barrett True-K no history (PPCP) vs. Shammas-L with <italic>P</italic>-values of 0.001 and 0.006. Concerning the proportion between &#x000B1;0.75 D, the comparison of FY-L with EVO-L and FY-L with Shammas-L showed statistical differences with both <italic>P</italic>-values of &#x0003C; 0.001. The comparison of Barrett True-K no history (MPCP) with EVO-L, Shammas-L, and Barrett True-K no history (PPCP) showed statistical differences with both <italic>P</italic>-values of &#x0003C; 0.001. The comparison of Barrett True-K no history (PPCP) with EVO-L and Shammas-L also showed statistical differences with <italic>P</italic>-values of &#x0003C; 0.001 and 0.002. Concerning the proportion of &#x000B1;1.0 D, the comparison of FY-L vs. EVO-L, FY-L vs. Shammas-L, and FY-L vs. Barrett True-K no history (PPCP) were significantly different with both <italic>P</italic>-values of &#x0003C; 0.001. The comparison of Barrett True-K no history (MPCP) with EVO-L, Shammas-L, and Barrett True-K no history (PPCP) showed statistical differences with <italic>P</italic>-values of &#x0003C; 0.001, &#x0003C; 0.001, and 0.021. The comparison of Barrett True-K no history (PPCP) with EVO-L and Shammas-L also showed statistical differences with <italic>P</italic>-values of &#x0003C; 0.001 and 0.015. Between the remaining groups, there were no statistically significant differences.</p>
<fig id="F3" position="float">
<label>Figure 3</label>
<caption><p>Evaluation of the proportion of eyes within specific ranges of prediction errors.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmed-10-1241824-g0003.tif"/>
</fig></sec>
<sec sec-type="discussion" id="s4">
<title>Discussion</title>
<p>Due to its safety, effectiveness, predictability, and lack of issues connected to valves, small-incision lenticule extraction (SMILE) is preferred among patients (<xref ref-type="bibr" rid="B17">17</xref>, <xref ref-type="bibr" rid="B18">18</xref>). Given an aging population, the number of patients who have been previously treated with SMILE and require cataract surgery is predicted to increase. It is achievable to precisely calculate IOL power after PRK or LASIK using a variety of empirically optimized formulas that are available as online calculators, with or without preoperative refractive data (<xref ref-type="bibr" rid="B19">19</xref>). In the methods that do not demand clinical history information of the patients, the FY-L formula used the actual Ka &#x0002B; p method to adjust the measured corneal power, which was based on our previously published study in 2010 (<xref ref-type="bibr" rid="B15">15</xref>). The Adult Eye Preferred Practice Pattern<sup>&#x000AE;</sup> guidelines (PPP), which were written by members of the Cataract and Anterior Segment Preferred Practice Pattern<sup>&#x000AE;</sup> Panel, mentioned this method in 2017 and 2021 (<xref ref-type="bibr" rid="B20">20</xref>, <xref ref-type="bibr" rid="B21">21</xref>). To estimate the ELP, the FY-L formula was based on the FY-IOL formula, which was optimized in groups based on different AL, ACD, anterior and posterior corneal power, and LT. In prior studies, the FY-L formula displayed high precision in IOL power predictions post-LASIK or PRK (<xref ref-type="bibr" rid="B15">15</xref>, <xref ref-type="bibr" rid="B22">22</xref>). In our study, the FY-L formula was compared to three established IOL power calculation formulas, including EVO-L, Shammas-L, and Barrett True-K no history, in eyes receiving cataract surgery after SMILE. The same IOL was virtually implanted before and after SMILE in the theoretical model of this study.</p>
<p>It is considered that the IOL-Dif should be equivalent to the SMILE-Dif (<xref ref-type="bibr" rid="B23">23</xref>, <xref ref-type="bibr" rid="B24">24</xref>). The IOL power was calculated employing the Haigis formula for the following there reasons before SMILE: (1) Since this study is based on a theoretical model and not on actual IOL implantation, the postoperative refractive outcomes are simulated data. Using the same formula before and after surgery may lead to errors in the calculations. Barrett True-K no history was based on Barrett Universal II for the IOL power calculations. We intend to use a formula before SMILE that does not correlate with the formulas used for the IOL power calculations after SMILE. (2) The patients in this study had an AL range between 23.28 and 28.11 mm, and both clinical application and previous studies showed the good accuracy of the Haigis formula for IOL calculations in this population (<xref ref-type="bibr" rid="B25">25</xref>&#x02013;<xref ref-type="bibr" rid="B27">27</xref>). (3) The Haigis formula has been published publicly for its calculation; therefore, it is easier to optimize the IOL constants with this formula.</p>
<p>In the present study, calculations with the FY-L formula yielded very accurate results with an average PE 0.06 &#x000B1; 0.76 D, an average AE 0.58 D, and a MedAE 0.47 D. Thereby, 87.5% of the eyes analyzed fell within the range of &#x000B1;1 D, while 70% were within &#x000B1;0.75 D, and 46.3 and 28.8% of the eyes were within the limits of &#x000B1;0.50 and &#x000B1;0.25 D, respectively. Our investigation found promising outcomes with the Barrett True-K no history for cases with actual posterior corneal power, with an average PE of 0.36 &#x000B1; 0.76 D, an average AE of 0.64 D, and an MAE of 0.55 D. In total, 78.8% of the eyes examined were within &#x000B1;1 D, 62.5% were within &#x000B1;0.75 D, 46.3% were in the &#x000B1;0.5 D range, and 30.0% were in the &#x000B1;0.25 D range for Barrett True-K no history (MPCP). The FY-L formula shows similar predictability as the Barrett True-K formula when considering the measured cornea power of the posterior surface. The accuracy of the Barrett True-K no history formula was slightly reduced when the corneal power of the posterior surface was not imputed but estimated. According to Savini et al., the Barrett True-K formula had better accuracy with the input of examination of the corneal posterior surface and preoperative details of the keratorefractive operation (<xref ref-type="bibr" rid="B28">28</xref>). In prior studies, corneal powers substantially altered in the anterior corneal surface while not changing in the posterior corneal surface, both LASIK, PRK, and SMILE (<xref ref-type="bibr" rid="B29">29</xref>). Our data suggest the same change. Therefore, the post-SMILE IOL power estimate would be more reliable if the formulas used both anterior and posterior corneal power. In Meziane Elotmani&#x00027;s study, calculations after SMILE with Okulix provided highly accurate results with an average PE of 0.002 &#x000B1; 0.453 D, and 79% of the cases examined were within &#x000B1;0.50D (<xref ref-type="bibr" rid="B24">24</xref>). However, the pre-SMILE IOL power was estimated employing multiple formulas rather than a common formula as a standard in the study. In addition, no other formulas that used measurements of both the anterior and posterior cornea, such as the Barrett True-K formula, were compared in the article. Lischke et al. also showed in research that ray tracing gives the greatest accuracy IOL power estimation after SMILE, with an average PE of 0.18 &#x000B1; 0.48 D (<xref ref-type="bibr" rid="B30">30</xref>). The FY-L formula showed comparable results with these two formulas.</p>
<p>In our calculations of eyes after SMILE, the EVO-L formula yielded a tendency for a hyperopic shift, and the Shammas-L formula yielded a tendency for a myopic shift. The mean arithmetic PE of the EVO-L formula was 0.85 &#x000B1; 0.82 D, and the MAE was 0.93 D. In this study, Shammas-L provided the lowest accuracy, with an average PE of &#x02212;0.91 &#x000B1; 0.77 D and the lowest &#x000B1;0.50 D accuracy of 23.8% and &#x000B1;0.25 D accuracy of 13.8%. Lischke et al. also showed in their research that the biggest IOL power overestimation was produced by the Shammas-L formula, with obtained a PE of &#x02212;0.96 &#x000B1; 1.14 D (<xref ref-type="bibr" rid="B30">30</xref>).</p>
<p>In summary, the outcomes of this study show that the FY-L formula offers satisfactory outcomes in estimating the IOL power in the eyes after SMILE. To the best of our knowledge, this is the first instance in which the FY-L formula has been used to determine the intraocular lens power after SMILE. In addition, the Barrett True-K no history formula increased its accuracy when the posterior corneal power was used instead of only the anterior corneal measurements. These outcomes show that, in eyes with prior SMILE, selecting the correct IOL provides significant benefits when the corneal posterior surface has been taken into consideration in IOL calculations.</p>
<p>This study had at least three limitations. First, a theoretical calculation model was presented in the study. The most accurate way to contrast multiple IOL power calculation methods would be by investigating the real postoperative refraction outcomes of cataract surgery after SMILE. However, these clinical data are currently unavailable. Second, the IOLMaster 700 and Pentacam HR, the equipment used in this study, apply different measurement techniques and might deliver different results. Therefore, in the follow-up study, the results of the calculation using the posterior corneal power obtained from different measurement devices should be compared and examined. Third, including the Ray Tracing Formula, Okulix, and Total Keratometry Method, which also used both anterior and posterior corneal measurements. In this article, there is no comparison of the methods mentioned above. In a follow-up study, we will compare these methods for a more comprehensive result.</p></sec>
<sec sec-type="data-availability" id="s5">
<title>Data availability statement</title>
<p>The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.</p></sec>
<sec sec-type="ethics-statement" id="s6">
<title>Ethics statement</title>
<p>The studies involving humans were approved by Medical Ethics Committee, Fuzhou Eye Hospital. The studies were conducted in accordance with the local legislation and institutional requirements. The participants provided their written informed consent to participate in this study.</p></sec>
<sec sec-type="author-contributions" id="s7">
<title>Author contributions</title>
<p>XY and GZ contributed to the concept and design of the study. YH and DZ performed the acquisition of data. YH and LL analyzed and interpreted the data and performed the statistical analysis. YH drafted the manuscript. LL, YW, and RZ performed a critical revision of the manuscript for important intellectual content. ZW and XY provide administrative, technical, or material support. All authors contributed to the article and approved the submitted version.</p></sec>
</body>
<back>


<sec sec-type="COI-statement" id="conf1">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec sec-type="disclaimer" id="s8">
<title>Publisher&#x00027;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>

<ref-list>
<title>References</title>
<ref id="B1">
<label>1.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ahmed</surname> <given-names>AA</given-names></name> <name><surname>Hatch</surname> <given-names>KM</given-names></name></person-group>. <article-title>Advantages of small incision lenticule extraction (SMILE) for mass eye and ear special issue</article-title>. <source>Semin Ophthalmol.</source> (<year>2020</year>) <volume>35</volume>:<fpage>224</fpage>&#x02013;<lpage>31</lpage>. <pub-id pub-id-type="doi">10.1080/08820538.2020.1807028</pub-id><pub-id pub-id-type="pmid">32892680</pub-id></citation></ref>
<ref id="B2">
<label>2.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wang</surname> <given-names>L</given-names></name> <name><surname>Koch</surname> <given-names>DD</given-names></name></person-group>. <article-title>Intraocular lens power calculations in eyes with previous corneal refractive surgery: challenges, approaches, and outcomes</article-title>. <source>Taiwan J Ophthalmol.</source> (<year>2022</year>) <volume>12</volume>:<fpage>22</fpage>&#x02013;<lpage>31</lpage>. <pub-id pub-id-type="doi">10.4103/tjo.tjo_38_21</pub-id><pub-id pub-id-type="pmid">35399961</pub-id></citation></ref>
<ref id="B3">
<label>3.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Aramberri</surname> <given-names>J</given-names></name></person-group>. <article-title>Intraocular lens power calculation after corneal refractive surgery: double-K method</article-title>. <source>J Cataract Refract Surg.</source> (<year>2003</year>) <volume>29</volume>:<fpage>2063</fpage>&#x02013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1016/S0886-3350(03)00957-X</pub-id><pub-id pub-id-type="pmid">23415780</pub-id></citation></ref>
<ref id="B4">
<label>4.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Holladay</surname> <given-names>JT</given-names></name></person-group>. <article-title>Cataract surgery in patients with previous keratorefractive surgery (RK, PRK, and LASIK)</article-title>. <source>Ophthalmic Pract</source>. (<year>1997</year>) <volume>15</volume>:<fpage>238</fpage>&#x02013;<lpage>44</lpage>.</citation>
</ref>
<ref id="B5">
<label>5.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tang</surname> <given-names>M</given-names></name> <name><surname>Li</surname> <given-names>Y</given-names></name> <name><surname>Avila</surname> <given-names>M</given-names></name> <name><surname>Huang</surname> <given-names>D</given-names></name></person-group>. <article-title>Measuring total corneal power before and after laser <italic>in situ</italic> keratomileusis with high-speed optical coherence tomography</article-title>. <source>J Cataract Refract Surg.</source> (<year>2006</year>) <volume>32</volume>:<fpage>1843</fpage>&#x02013;<lpage>50</lpage>. <pub-id pub-id-type="doi">10.1016/j.jcrs.2006.04.046</pub-id><pub-id pub-id-type="pmid">17081867</pub-id></citation></ref>
<ref id="B6">
<label>6.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hugger</surname> <given-names>P</given-names></name> <name><surname>Kohnen</surname> <given-names>T</given-names></name> <name><surname>La Rosa</surname> <given-names>FA</given-names></name> <name><surname>Holladay</surname> <given-names>JT</given-names></name> <name><surname>Koch</surname> <given-names>DD</given-names></name></person-group>. <article-title>Comparison of changes in manifest refraction and corneal power after photorefractive keratectomy</article-title>. <source>Am J Ophthalmol.</source> (<year>2000</year>) <volume>129</volume>:<fpage>68</fpage>&#x02013;<lpage>75</lpage>. <pub-id pub-id-type="doi">10.1016/S0002-9394(99)00268-8</pub-id><pub-id pub-id-type="pmid">10653415</pub-id></citation></ref>
<ref id="B7">
<label>7.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Feiz</surname> <given-names>V</given-names></name> <name><surname>Mannis</surname> <given-names>MJ</given-names></name> <name><surname>Garcia-Ferrer</surname> <given-names>F</given-names></name> <name><surname>Kandavel</surname> <given-names>G</given-names></name> <name><surname>Darlington</surname> <given-names>JK</given-names></name> <name><surname>Kim</surname> <given-names>E</given-names></name> <etal/></person-group>. <article-title>Intraocular lens power calculation after laser <italic>in situ</italic> keratomileusis for myopia and hyperopia: a standardized approach</article-title>. <source>Cornea.</source> (<year>2001</year>) <volume>20</volume>:<fpage>792</fpage>&#x02013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1097/00003226-200111000-00003</pub-id><pub-id pub-id-type="pmid">11685053</pub-id></citation></ref>
<ref id="B8">
<label>8.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Holladay</surname> <given-names>JT</given-names></name></person-group>. <article-title>Consultations in refractive surgery (letter)</article-title>. <source>Refract Corneal Surg.</source> (<year>1989</year>) <volume>5</volume>:<fpage>20</fpage>. <pub-id pub-id-type="doi">10.3928/1081-597X-19890501-17</pub-id></citation>
</ref>
<ref id="B9">
<label>9.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Walter</surname> <given-names>KA</given-names></name> <name><surname>Gagnon</surname> <given-names>MR</given-names></name> <name><surname>Hoopes PC</surname> <given-names>Jr</given-names></name> <name><surname>Dickinson</surname> <given-names>PJ</given-names></name></person-group>. <article-title>Accurate intraocular lens power calculation after myopic laser <italic>in situ</italic> keratomileusis, bypassing corneal power</article-title>. <source>J Cataract Refract Surg.</source> (<year>2006</year>) <volume>32</volume>:<fpage>425</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1016/j.jcrs.2005.12.140</pub-id><pub-id pub-id-type="pmid">16631050</pub-id></citation></ref>
<ref id="B10">
<label>10.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Abulafia</surname> <given-names>A</given-names></name> <name><surname>Hill</surname> <given-names>WE</given-names></name> <name><surname>Wang</surname> <given-names>L</given-names></name> <name><surname>Reitblat</surname> <given-names>O</given-names></name> <name><surname>Koch</surname> <given-names>DD</given-names></name></person-group>. <article-title>Intraocular lens power calculation in eyes after laser <italic>in situ</italic> keratomileusis or photorefractive keratectomy for myopia</article-title>. <source>Asia Pac J Ophthalmol.</source> (<year>2017</year>) <volume>6</volume>:<fpage>332</fpage>&#x02013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.22608/APO.2017187</pub-id><pub-id pub-id-type="pmid">28780776</pub-id></citation></ref>
<ref id="B11">
<label>11.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chen</surname> <given-names>X</given-names></name> <name><surname>Yuan</surname> <given-names>F</given-names></name> <name><surname>Wu</surname> <given-names>L</given-names></name></person-group>. <article-title>Metaanalysis of intraocular lens power calculation after laser refractive surgery in myopic eyes</article-title>. <source>J Cataract Refract Surg.</source> (<year>2016</year>) <volume>42</volume>:<fpage>163</fpage>&#x02013;<lpage>70</lpage>. <pub-id pub-id-type="doi">10.1016/j.jcrs.2015.12.005</pub-id><pub-id pub-id-type="pmid">26948792</pub-id></citation></ref>
<ref id="B12">
<label>12.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Whang</surname> <given-names>WJ</given-names></name> <name><surname>Hoffer</surname> <given-names>KJ</given-names></name> <name><surname>Kim</surname> <given-names>SJ</given-names></name> <name><surname>Chung</surname> <given-names>SH</given-names></name> <name><surname>Savini</surname> <given-names>G</given-names></name></person-group>. <article-title>Comparison of intraocular lens power formulas according to axial length after myopic corneal laser refractive surgery</article-title>. <source>J Cataract Refract Surg.</source> (<year>2021</year>) <volume>47</volume>:<fpage>297</fpage>&#x02013;<lpage>303</lpage>. <pub-id pub-id-type="doi">10.1097/j.jcrs.0000000000000445</pub-id><pub-id pub-id-type="pmid">32991505</pub-id></citation></ref>
<ref id="B13">
<label>13.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sandoval</surname> <given-names>HP</given-names></name> <name><surname>Serels</surname> <given-names>C</given-names></name> <name><surname>Potvin</surname> <given-names>R</given-names></name> <name><surname>Solomon</surname> <given-names>KD</given-names></name></person-group>. <article-title>Cataract surgery after myopic laser <italic>in situ</italic> keratomileusis: objective analysis to determine best formula and keratometry to use</article-title>. <source>J Cataract Refract Surg.</source> (<year>2021</year>) <volume>47</volume>:<fpage>465</fpage>&#x02013;<lpage>70</lpage>. <pub-id pub-id-type="doi">10.1097/j.jcrs.0000000000000472</pub-id><pub-id pub-id-type="pmid">33149048</pub-id></citation></ref>
<ref id="B14">
<label>14.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wei</surname> <given-names>L</given-names></name> <name><surname>Meng</surname> <given-names>J</given-names></name> <name><surname>Qi</surname> <given-names>J</given-names></name> <name><surname>Lu</surname> <given-names>Y</given-names></name> <name><surname>Zhu</surname> <given-names>X</given-names></name></person-group>. <article-title>Comparisons of intraocular lens power calculation methods for eyes with previous myopic laser refractive surgery: Bayesian network meta-analysis</article-title>. <source>J Cataract Refract Surg.</source> (<year>2021</year>) <volume>47</volume>:<fpage>1011</fpage>&#x02013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1097/j.jcrs.0000000000000562</pub-id><pub-id pub-id-type="pmid">34290197</pub-id></citation></ref>
<ref id="B15">
<label>15.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hu</surname> <given-names>YQ</given-names></name> <name><surname>Ye</surname> <given-names>XY</given-names></name> <name><surname>Zhou XL Li</surname> <given-names>Y</given-names></name> <name><surname>Xu</surname> <given-names>CH</given-names></name> <name><surname>Tian</surname> <given-names>LL</given-names></name> <name><surname>Zhu</surname> <given-names>H</given-names></name> <etal/></person-group>. <article-title>Practical method to calculate post-LASIK corneal power: the actual K(a&#x0002B;p) method</article-title>. <source>Int J Ophthalmol.</source> (<year>2010</year>) <volume>3</volume>:<fpage>337</fpage>&#x02013;<lpage>41</lpage>. <pub-id pub-id-type="doi">10.3980/j.issn.2222-3959.2010.04.14</pub-id><pub-id pub-id-type="pmid">22553587</pub-id></citation></ref>
<ref id="B16">
<label>16.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hoffer</surname> <given-names>KJ</given-names></name> <name><surname>Savini</surname> <given-names>G</given-names></name></person-group>. <article-title>Update on intraocular lens power calculation study protocols: the better way to design and report clinical trials</article-title>. <source>Ophthalmology.</source> (<year>2021</year>) <volume>128</volume>:<fpage>e115</fpage>&#x02013;<lpage>20</lpage>. <pub-id pub-id-type="doi">10.1016/j.ophtha.2020.07.005</pub-id><pub-id pub-id-type="pmid">32653457</pub-id></citation></ref>
<ref id="B17">
<label>17.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kim</surname> <given-names>TI</given-names></name> <name><surname>Alio Del Barrio</surname> <given-names>JL</given-names></name> <name><surname>Wilkins</surname> <given-names>M</given-names></name> <name><surname>Cochener</surname> <given-names>B</given-names></name> <name><surname>Ang</surname> <given-names>M</given-names></name></person-group>. <article-title>Refractive surgery</article-title>. <source>Lancet.</source> (<year>2019</year>) <volume>393</volume>:<fpage>2085</fpage>&#x02013;<lpage>98</lpage>. <pub-id pub-id-type="doi">10.1016/S0140-6736(18)33209-4</pub-id><pub-id pub-id-type="pmid">31106754</pub-id></citation></ref>
<ref id="B18">
<label>18.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Samir</surname> <given-names>A</given-names></name> <name><surname>Lotfy</surname> <given-names>A</given-names></name> <name><surname>Heikal</surname> <given-names>MA</given-names></name> <name><surname>Abdelrahman Elsayed</surname> <given-names>AM</given-names></name></person-group>. <article-title>Small incision lenticule extraction for correction of pediatric unilateral anisometropic myopia</article-title>. <source>J Refract Surg.</source> (<year>2021</year>) <volume>37</volume>:<fpage>510</fpage>&#x02013;<lpage>5</lpage>. <pub-id pub-id-type="doi">10.3928/1081597X-20210506-02</pub-id><pub-id pub-id-type="pmid">34388076</pub-id></citation></ref>
<ref id="B19">
<label>19.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Savini</surname> <given-names>G</given-names></name> <name><surname>Barboni</surname> <given-names>P</given-names></name> <name><surname>Carbonelli</surname> <given-names>M</given-names></name> <name><surname>Ducoli</surname> <given-names>P</given-names></name> <name><surname>Hoffer</surname> <given-names>KJ</given-names></name></person-group>. <article-title>Intraocular lens power calculation after myopic excimer laser surgery: selecting the best method using available clinical data</article-title>. <source>J Cataract Refract Surg.</source> (<year>2015</year>) <volume>41</volume>:<fpage>1880</fpage>&#x02013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1016/j.jcrs.2015.10.026</pub-id><pub-id pub-id-type="pmid">26603397</pub-id></citation></ref>
<ref id="B20">
<label>20.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Miller</surname> <given-names>KM</given-names></name> <name><surname>Oetting</surname> <given-names>TA</given-names></name> <name><surname>Tweeten</surname> <given-names>JP</given-names></name> <name><surname>Carter</surname> <given-names>K</given-names></name> <name><surname>Lee</surname> <given-names>BS</given-names></name> <name><surname>Lin</surname> <given-names>S</given-names></name> <etal/></person-group>. <article-title>American academy of ophthalmology preferred practice pattern cataract/anterior segment P. Cataract in the adult eye preferred practice pattern</article-title>. <source>Ophthalmology.</source> (<year>2022</year>) <volume>129</volume>:<fpage>P1</fpage>&#x02013;<lpage>P126</lpage>. <pub-id pub-id-type="doi">10.1016/j.ophtha.2021.10.006</pub-id><pub-id pub-id-type="pmid">34780842</pub-id></citation></ref>
<ref id="B21">
<label>21.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Olson</surname> <given-names>RJ</given-names></name> <name><surname>Braga-Mele</surname> <given-names>R</given-names></name> <name><surname>Chen</surname> <given-names>SH</given-names></name> <name><surname>Miller</surname> <given-names>KM</given-names></name> <name><surname>Pineda R</surname> <given-names>2nd</given-names></name> <name><surname>Tweeten</surname> <given-names>JP</given-names></name> <etal/></person-group>. <article-title>Cataract in the adult eye preferred practice pattern(R)</article-title>. <source>Ophthalmology.</source> (<year>2017</year>) <volume>124</volume>:<fpage>P1</fpage>&#x02013;<lpage>P119</lpage>. <pub-id pub-id-type="doi">10.1016/j.ophtha.2016.09.027</pub-id><pub-id pub-id-type="pmid">27745902</pub-id></citation></ref>
<ref id="B22">
<label>22.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fang</surname> <given-names>X</given-names></name> <name><surname>Ben</surname> <given-names>S</given-names></name> <name><surname>Dong</surname> <given-names>Y</given-names></name> <name><surname>Chen</surname> <given-names>X</given-names></name> <name><surname>Xue</surname> <given-names>W</given-names></name> <name><surname>Wang</surname> <given-names>Y</given-names></name></person-group>. <article-title>Outcomes of the Haigis-L formula for calculating intraocular lens power in extreme long axis eyes after myopic laser <italic>in situ</italic> keratomileusis</article-title>. <source>Eye.</source> (<year>2022</year>) <volume>36</volume>:<fpage>1178</fpage>&#x02013;<lpage>84</lpage>. <pub-id pub-id-type="doi">10.1038/s41433-021-01551-9</pub-id><pub-id pub-id-type="pmid">34117389</pub-id></citation></ref>
<ref id="B23">
<label>23.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lazaridis</surname> <given-names>A</given-names></name> <name><surname>Schraml</surname> <given-names>F</given-names></name> <name><surname>Preussner</surname> <given-names>PR</given-names></name> <name><surname>Sekundo</surname> <given-names>W</given-names></name></person-group>. <article-title>Predictability of intraocular lens power calculation after small-incision lenticule extraction for myopia</article-title>. <source>J Cataract Refract Surg.</source> (<year>2021</year>) <volume>47</volume>:<fpage>304</fpage>&#x02013;<lpage>10</lpage>. <pub-id pub-id-type="doi">10.1097/j.jcrs.0000000000000405</pub-id><pub-id pub-id-type="pmid">32932366</pub-id></citation></ref>
<ref id="B24">
<label>24.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Meziane Elotmani</surname> <given-names>A</given-names></name> <name><surname>Messerschmidt-Roth</surname> <given-names>A</given-names></name> <name><surname>Nehme</surname> <given-names>A</given-names></name> <name><surname>Muller</surname> <given-names>HH</given-names></name> <name><surname>Sekundo</surname> <given-names>W</given-names></name></person-group>. <article-title>Comparison of intraocular lens power calculation formulas with and without total keratometry and ray tracing in patients with previous myopic SMILE</article-title>. <source>J Cataract Refract Surg.</source> (<year>2023</year>) <volume>49</volume>:<fpage>467</fpage>&#x02013;<lpage>73</lpage>. <pub-id pub-id-type="doi">10.1097/j.jcrs.0000000000001139</pub-id><pub-id pub-id-type="pmid">36700932</pub-id></citation></ref>
<ref id="B25">
<label>25.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fuest</surname> <given-names>M</given-names></name> <name><surname>Plange</surname> <given-names>N</given-names></name> <name><surname>Kuerten</surname> <given-names>D</given-names></name> <name><surname>Schellhase</surname> <given-names>H</given-names></name> <name><surname>Mazinani</surname> <given-names>BAE</given-names></name> <name><surname>Walter</surname> <given-names>P</given-names></name> <etal/></person-group>. <article-title>Intraocular lens power calculation for plus and minus lenses in high myopia using partial coherence interferometry</article-title>. <source>Int Ophthalmol.</source> (<year>2021</year>) <volume>41</volume>:<fpage>1585</fpage>&#x02013;<lpage>92</lpage>. <pub-id pub-id-type="doi">10.1007/s10792-020-01684-y</pub-id><pub-id pub-id-type="pmid">33521894</pub-id></citation></ref>
<ref id="B26">
<label>26.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lin</surname> <given-names>L</given-names></name> <name><surname>Xu</surname> <given-names>M</given-names></name> <name><surname>Mo</surname> <given-names>E</given-names></name> <name><surname>Huang</surname> <given-names>S</given-names></name> <name><surname>Qi</surname> <given-names>X</given-names></name> <name><surname>Gu</surname> <given-names>S</given-names></name> <etal/></person-group>. <article-title>Accuracy of newer generation IOL power calculation formulas in eyes with high axial myopia</article-title>. <source>J Refract Surg.</source> (<year>2021</year>) <volume>37</volume>:<fpage>754</fpage>&#x02013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.3928/1081597X-20210712-08</pub-id><pub-id pub-id-type="pmid">34756144</pub-id></citation></ref>
<ref id="B27">
<label>27.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ghanem</surname> <given-names>AA</given-names></name> <name><surname>El-Sayed</surname> <given-names>HM</given-names></name></person-group>. <article-title>Accuracy of intraocular lens power calculation in high myopia</article-title>. <source>Oman J Ophthalmol.</source> (<year>2010</year>) <volume>3</volume>:<fpage>126</fpage>&#x02013;<lpage>30</lpage>. <pub-id pub-id-type="doi">10.4103/0974-620X.71888</pub-id><pub-id pub-id-type="pmid">21120048</pub-id></citation></ref>
<ref id="B28">
<label>28.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Savini</surname> <given-names>G</given-names></name> <name><surname>Hoffer</surname> <given-names>KJ</given-names></name> <name><surname>Barrett</surname> <given-names>GD</given-names></name></person-group>. <article-title>Results of the barrett true-K formula for IOL power calculation based on Scheimpflug camera measurements in eyes with previous myopic excimer laser surgery</article-title>. <source>J Cataract Refract Surg.</source> (<year>2020</year>) <volume>46</volume>:<fpage>1016</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1097/j.jcrs.0000000000000205</pub-id><pub-id pub-id-type="pmid">32271267</pub-id></citation></ref>
<ref id="B29">
<label>29.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gyldenkerne</surname> <given-names>A</given-names></name> <name><surname>Ivarsen</surname> <given-names>A</given-names></name> <name><surname>Hjortdal</surname> <given-names>J</given-names></name></person-group>. <article-title>Comparison of corneal shape changes and aberrations induced By FS-LASIK and SMILE for myopia</article-title>. <source>J Refract Surg</source>. (<year>2015</year>) <volume>31</volume>:<fpage>223</fpage>&#x02013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.3928/1081597X-20150303-01</pub-id><pub-id pub-id-type="pmid">25751842</pub-id></citation></ref>
<ref id="B30">
<label>30.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lischke</surname> <given-names>R</given-names></name> <name><surname>Sekundo</surname> <given-names>W</given-names></name> <name><surname>Wiltfang</surname> <given-names>R</given-names></name> <name><surname>Bechmann</surname> <given-names>M</given-names></name> <name><surname>Kreutzer</surname> <given-names>T</given-names></name> <name><surname>Priglinger</surname> <given-names>S</given-names></name> <etal/></person-group>. <article-title>IOL power calculations and cataract surgery in eyes with previous small incision lenticule extraction</article-title>. <source>J Clin Med</source>. (<year>2022</year>) <volume>11</volume>:<fpage>4418</fpage>. <pub-id pub-id-type="doi">10.3390/jcm11154418</pub-id><pub-id pub-id-type="pmid">35956035</pub-id></citation></ref>
</ref-list> 
</back>
</article> 