<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Med.</journal-id>
<journal-title>Frontiers in Medicine</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Med.</abbrev-journal-title>
<issn pub-type="epub">2296-858X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fmed.2023.1137514</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Medicine</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Artificial intelligence-based <sup>68</sup>Ga-DOTATOC PET denoising for optimizing <sup>68</sup>Ge/<sup>68</sup>Ga generator use throughout its lifetime</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name><surname>Quak</surname> <given-names>Elske</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Weyts</surname> <given-names>Kathleen</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Jaudet</surname> <given-names>Cyril</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Prigent</surname> <given-names>Ana&#x00EF;s</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Foucras</surname> <given-names>Gauthier</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name><surname>Lasnon</surname> <given-names>Charline</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff4"><sup>4</sup></xref>
<xref ref-type="corresp" rid="c001"><sup>&#x002A;</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/1069409/overview"/>
</contrib>
</contrib-group>
<aff id="aff1"><sup>1</sup><institution>Nuclear Medicine Department, Comprehensive Cancer Centre Fran&#x00E7;ois Baclesse, UNICANCER</institution>, <addr-line>Caen</addr-line>, <country>France</country></aff>
<aff id="aff2"><sup>2</sup><institution>Radiophysics Department, Comprehensive Cancer Centre Fran&#x00E7;ois Baclesse, UNICANCER</institution>, <addr-line>Caen</addr-line>, <country>France</country></aff>
<aff id="aff3"><sup>3</sup><institution>Radiopharmacy Department, Comprehensive Cancer Centre Fran&#x00E7;ois Baclesse, UNICANCER</institution>, <addr-line>Caen</addr-line>, <country>France</country></aff>
<aff id="aff4"><sup>4</sup><institution>UNICAEN, INSERM 1086 ANTICIPE, Normandy University</institution>, <addr-line>Caen</addr-line>, <country>France</country></aff>
<author-notes>
<fn fn-type="edited-by"><p>Edited by: Giorgio Treglia, Ente Ospedaliero Cantonale (EOC), Switzerland</p></fn>
<fn fn-type="edited-by"><p>Reviewed by: Francesco Dondi, Universit&#x00E0; degli Studi di Brescia, Italy; Salvatore Annunziata, Fondazione Policlinico Universitario A. Gemelli IRCCS, Italy</p></fn>
<corresp id="c001">&#x002A;Correspondence: Charline Lasnon, <email>c.lasnon@baclesse.unicancer.fr</email>; <ext-link ext-link-type="uri" xlink:href="https://orcid.org/0000-0001-5643-1668">orcid.org/0000-0001-5643-1668</ext-link></corresp>
<fn fn-type="other" id="fn004"><p>This article was submitted to Nuclear Medicine, a section of the journal Frontiers in Medicine</p></fn>
</author-notes>
<pub-date pub-type="epub">
<day>13</day>
<month>03</month>
<year>2023</year>
</pub-date>
<pub-date pub-type="collection">
<year>2023</year>
</pub-date>
<volume>10</volume>
<elocation-id>1137514</elocation-id>
<history>
<date date-type="received">
<day>04</day>
<month>01</month>
<year>2023</year>
</date>
<date date-type="accepted">
<day>30</day>
<month>01</month>
<year>2023</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x00A9; 2023 Quak, Weyts, Jaudet, Prigent, Foucras and Lasnon.</copyright-statement>
<copyright-year>2023</copyright-year>
<copyright-holder>Quak, Weyts, Jaudet, Prigent, Foucras and Lasnon</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license>
</permissions>
<abstract>
<sec>
<title>Introduction</title>
<p>The yield per elution of a <sup>68</sup>Ge/<sup>68</sup>Ga generator decreases during its lifespan. This affects the number of patients injected per elution or the injected dose per patient, thereby negatively affecting the cost of examinations and the quality of PET images due to increased image noise. We aimed to investigate whether AI-based PET denoising can offset this decrease in image quality parameters.</p>
</sec>
<sec>
<title>Methods</title>
<p>All patients addressed to our PET unit for a <sup>68</sup>Ga-DOTATOC PET/CT from April 2020 to February 2021 were enrolled. Forty-four patients underwent their PET scans according to Protocol_FixedDose (150 MBq) and 32 according to Protocol_WeightDose (1.5 MBq/kg). Protocol_WeightDose examinations were processed using the Subtle PET software (Protocol_WeightDose<sup>AI</sup>). Liver and vascular SUV mean were recorded as well as SUVmax, SUVmean and metabolic tumour volume (MTV) of the most intense tumoural lesion and its background SUVmean. Liver and vascular coefficients of variation (CV), tumour-to-background and tumour-to-liver ratios were calculated.</p>
</sec>
<sec>
<title>Results</title>
<p>The mean injected dose of 2.1 (0.4) MBq/kg per patient was significantly higher in the Protocol_FixedDose group as compared to 1.5 (0.1) MBq/kg for the Protocol_WeightDose group. Protocol_WeightDose led to noisier images than Protocol_FixedDose with higher CVs for liver (15.57% &#x00B1; 4.32 vs. 13.04% &#x00B1; 3.51, <italic>p</italic> = 0.018) and blood-pool (28.67% &#x00B1; 8.65 vs. 22.25% &#x00B1; 10.37, <italic>p</italic> = 0.0003). Protocol_WeightDose<sup>AI</sup> led to less noisy images than Protocol_WeightDose with lower liver CVs (11.42% &#x00B1; 3.05 vs. 15.57% &#x00B1; 4.32, <italic>p</italic> &#x003C; 0.0001) and vascular CVs (16.62% &#x00B1; 6.40 vs. 28.67% &#x00B1; 8.65, <italic>p</italic> &#x003C; 0.0001). Tumour-to-background and tumour-to-liver ratios were lower for protocol_WeightDose<sup>AI</sup>: 6.78 &#x00B1; 3.49 vs. 7.57 &#x00B1; 4.73 (<italic>p</italic> = 0.01) and 5.96 &#x00B1; 5.43 vs. 6.77 &#x00B1; 6.19 (<italic>p</italic> &#x003C; 0.0001), respectively. MTVs were higher after denoising whereas tumour SUVmax were lower: the mean% differences in MTV and SUVmax were + 11.14% (95% CI = 4.84&#x2013;17.43) and &#x2212;3.92% (95% CI = &#x2212;6.25 to &#x2212;1.59).</p>
</sec>
<sec>
<title>Conclusion</title>
<p>The degradation of PET image quality due to a reduction in injected dose at the end of the <sup>68</sup>Ge/<sup>68</sup>Ga generator lifespan can be effectively counterbalanced by using AI-based PET denoising.</p>
</sec>
</abstract>
<kwd-group>
<kwd>PET</kwd>
<kwd>gallium-68</kwd>
<kwd>artificial intelligence</kwd>
<kwd>denoising</kwd>
<kwd>deep learning</kwd>
</kwd-group>
<counts>
<fig-count count="3"/>
<table-count count="1"/>
<equation-count count="0"/>
<ref-count count="25"/>
<page-count count="9"/>
<word-count count="4980"/>
</counts>
</article-meta>
</front>
<body>
<sec id="S1">
<title>Background</title>
<p>The half-life of the <sup>68</sup>Ga isotope is short (68 min) requiring on-site synthesis of <sup>68</sup>Ga-labeled tracers. The advent of commercially available <sup>68</sup>Ge/<sup>68</sup>Ga generators and labeling kits has facilitated the synthesis of <sup>68</sup>Ga-labeled PET tracers in the hospital&#x2019;s radiopharmacy and contributed to its increased use. Frequently used <sup>68</sup>Ga-labeled PET tracers target somatostatin receptors in neuroendocrine tumours (NETs) (<xref ref-type="bibr" rid="B1">1</xref>) and prostate-specific membrane antigen (PSMA) in prostate cancer (<xref ref-type="bibr" rid="B2">2</xref>). The clinical benefits of <sup>68</sup>Ga-labeled PET tracers for imaging and diagnosis of NETs include improved sensitivity and specificity compared to other imaging modalities, as well as the ability to detect small and functional tumours. It is recommended as the first choice for PET/CT imaging of most NETs by international guidelines (<xref ref-type="bibr" rid="B3">3</xref>&#x2013;<xref ref-type="bibr" rid="B6">6</xref>). Since the half-life of the parent <sup>68</sup>Ge isotope is 271 days, the generator lifespan is about 1 year. At the start of the lifespan, one generator elution allows the labeling of approximately four doses based on an injected dose of 3 MBq/kg. However, as the <sup>68</sup>Ge parent of the generator decays over time, the number of doses of tracer obtained per elution decreases. This means that during the lifespan of the generator, the number of examinations per elution and/or the activity injected in the patient in MBq/kg decreases, thereby negatively affecting the cost of the procedure or the quality of PET images due to increased image noise. Moreover, due to the short half-life of <sup>68</sup>Ga, the increase in image noise can hardly be counterbalanced by an increase in PET acquisition time, particularly if several patients injected with the same elution need to be scanned.</p>
<p>To optimize the use of the <sup>68</sup>Ge/<sup>68</sup>Ga generator while maintaining PET image quality, innovative approaches based on artificial intelligence (AI) are opening up new perspectives. By using AI, the acquisition time per exam and/or the injected activity can be reduced without compromising image quality. Notably, several AI-based post-reconstruction PET/CT image enhancements have been recently developed (<xref ref-type="bibr" rid="B7">7</xref>). A post-reconstruction PET denoising software (SubtlePET&#x2122;, Subtle Medical&#x00A9;, Stanford, USA provided by Incepto&#x00A9;, France) that was recently developed by using a deep convolutional neural network on a library of millions of paired images (native and low-dose images) to learn and tune the optimal parameters to compute an estimate of the native image. Currently, only a few clinical publications have evaluated its use in oncology, all of them dealing with <sup>18</sup>F-FDG PET images (<xref ref-type="bibr" rid="B8">8</xref>&#x2013;<xref ref-type="bibr" rid="B12">12</xref>). At present, SubtlePET&#x2122; is FDA (Food and Drug Administration)-approved for use with 18F-FDG and 18F-Amyloid tracers and is now CE (European Conformity)-marked for use with 18F-FDG, 18F-Amyloid, 18F-Fluciclovine, 18F-DOPA, 18F-Choline, 18F-DCFPyL, Ga-68 Dotatate, and Ga-68 PSMA PET images (<xref ref-type="bibr" rid="B13">13</xref>). However, no clinical study has demonstrated the value of this software to enhance the quality of low-dose <sup>68</sup>Ga PET images, even though nuclear medicine departments are concerned about this issue. Various other deep learning-based methods have been evaluated for low-dose imaging and resolution enhancement, but none of them are currently validated for clinical use (<xref ref-type="bibr" rid="B14">14</xref>). Denoising techniques for <sup>68</sup>Ga-labeled radiotracers in PET imaging have been explored using both reconstruction-based methods and deep-learning techniques. It has been shown that both strategies can significantly improve the image quality by decreasing the noise level in low-dose <sup>68</sup>Ga PET scans (<xref ref-type="bibr" rid="B15">15</xref>).</p>
<p>Therefore, the aim of this prospective study was to explore the performance of this software to enhance the quality of <sup>68</sup>Ga-DOTATOC PET images, and to compare it to a standard Gaussian post-filtering approach. We hypothesized that to optimize the use of a <sup>68</sup>Ge/<sup>68</sup>Ga generator throughout its lifetime, AI-based PET denoising might be a solution to maintain correct image quality.</p>
</sec>
<sec id="S2" sec-type="materials|methods">
<title>Materials and methods</title>
<sec id="S2.SS1">
<title>Population</title>
<p>All patients were informed about the use of their clinical and PET data for research purposes. Patients had the right to refuse the transmission of data covered by medical confidentiality used and processed in the context of this research. The procedure was declared to the National Institute for Health Data with the registration no. F20210720123322. Patients over 18 years old addressed to our PET unit for a <sup>68</sup>Ga-DOTATOC PET from April 2020 to February 2021 were enrolled. Sex, age and body mass index (BMI) were extracted from electronic patient records.</p>
</sec>
<sec id="S2.SS2">
<title>Positron emission tomography acquisition and reconstruction</title>
<p>All patients underwent their examinations on a VEREOS PET/CT system (Phillips). All PET emission acquisitions were performed 60 min after injection, from the skull to mid-thighs with 1 min 30 per bed position. Images were reconstructed with four iterations four subsets with point spread function (PSF) and 2-mm voxel size. All images were acquired and reconstructed according to the European guidelines (<xref ref-type="bibr" rid="B16">16</xref>). In the event of treatment with somatostatin analogs, the treatment was stopped at least 21 days before the PET scan.</p>
<p>Between April and November 2020, corresponding to the first months of the generator&#x2019;s lifespan, patients were injected intravenously with a fixed dose of 150 MBq of <sup>68</sup>Ga-DOTATOC. This protocol is subsequently referred to as <italic>protocol_FixedDose</italic>.</p>
<p>Between December 2020 and February 2021, i.e., the last months of the generator&#x2019;s lifespan, patients were injected intravenously with 1.5 MBq/kg of <sup>68</sup>Ga-DOTATOC. This protocol is subsequently referred to as <italic>protocol_WeightDose</italic>. These PET examinations were then processed using Subtle PET&#x2122;software and was subsequently referred to as <italic>protocol_WeightDose<sup>AI</sup></italic>.</p>
<p>In addition, NEMA-NU2 image quality phantom acquisitions were performed and analyzed to find a specific Gaussian post-filter (GPF). This GPF will allow the <italic>protocol_WeightDose</italic> to recover a noise in the image equivalent to the former <italic>protocol_FixedDose</italic> (<xref ref-type="bibr" rid="B17">17</xref>). Measurements were made with a sphere-to-background ratio set at six and two background <sup>68</sup>Ga solution concentrations: 2.1 MBq/mL and 1.5 MBq/mL, corresponding to the average injected activities for <italic>protocol_FixedDose</italic> and <italic>protocol_WeightDose</italic>, respectively. CVs were measured in a VOI larger than 100 ml for both acquisitions. The width of the fitted GPF was optimized by dichotomy. This GPF was then applied to all <italic>protocol_WeightDose</italic> acquisitions and the resulting images referred to as <italic>protocol_WeightDose<sup>Gaussian</sup></italic>.</p>
</sec>
<sec id="S2.SS3">
<title>Clinical PET data extraction</title>
<p>Positron emission tomography scans were equally and randomly assigned to two senior nuclear physicians. PET images were reviewed on MIM (MIM Software, Cleveland, OH, USA, version 5.6.5).</p>
<p>The following features were recorded separately for each PET acquisition:</p>
<list list-type="simple">
<list-item>
<label>&#x2022;</label>
<p>Liver SUV<sub>mean</sub> (mean standard uptake value) and standard deviation (SD) from a 3 cm diameter spherical volume of interest (VOI) placed on the right liver lobe.</p>
</list-item>
<list-item>
<label>&#x2022;</label>
<p>Vascular SUV<sub>mean</sub> and SD from a 2 cm diameter spherical-VOI placed on the descending aorta.</p>
</list-item>
<list-item>
<label>&#x2022;</label>
<p>Muscular SUV<sub>mean</sub> and SD from a 2 cm spherical-VOI placed on the left erector spinae muscle at the height of the adrenals.</p>
</list-item>
<list-item>
<label>&#x2022;</label>
<p>Tumour SUV<sub>max</sub>, SUV<sub>mean</sub> and metabolic tumour volume (MTV) from a 40% isocontour VOI placed on the most intense lesion, as well as its location.</p>
</list-item>
<list-item>
<label>&#x2022;</label>
<p>The tumour background SUV<sub>mean</sub> from a doughnut-shaped VOI surrounding the most intense lesion VOI.</p>
</list-item>
</list>
<p>Physiological noises were evaluated by means of coefficients of variations (CV) calculated as follows: <inline-formula><mml:math id="INEQ1"><mml:mrow><mml:mfrac><mml:mrow><mml:mi>S</mml:mi><mml:mo>&#x2062;</mml:mo><mml:mi>D</mml:mi></mml:mrow><mml:mrow><mml:mi>S</mml:mi><mml:mo>&#x2062;</mml:mo><mml:mi>U</mml:mi><mml:mo>&#x2062;</mml:mo><mml:msub><mml:mi>V</mml:mi><mml:mrow><mml:mtext>mean</mml:mtext></mml:mrow></mml:msub></mml:mrow></mml:mfrac><mml:mo>&#x00D7;</mml:mo><mml:mpadded width="+2.8pt"><mml:mn>100</mml:mn></mml:mpadded><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mo>%</mml:mo><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow></mml:math></inline-formula>. Lesion-to-background ratios were computed as follows: <inline-formula><mml:math id="INEQ2"><mml:mfrac><mml:mrow><mml:mi>t</mml:mi><mml:mo>&#x2062;</mml:mo><mml:mi>u</mml:mi><mml:mo>&#x2062;</mml:mo><mml:mi>m</mml:mi><mml:mo>&#x2062;</mml:mo><mml:mi>o</mml:mi><mml:mo>&#x2062;</mml:mo><mml:mpadded width="+2.8pt"><mml:mi>r</mml:mi></mml:mpadded><mml:mo>&#x2062;</mml:mo><mml:mi>S</mml:mi><mml:mo>&#x2062;</mml:mo><mml:mi>U</mml:mi><mml:mo>&#x2062;</mml:mo><mml:msub><mml:mi>V</mml:mi><mml:mrow><mml:mtext>mean</mml:mtext></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:mi>b</mml:mi><mml:mo>&#x2062;</mml:mo><mml:mi>a</mml:mi><mml:mo>&#x2062;</mml:mo><mml:mi>c</mml:mi><mml:mo>&#x2062;</mml:mo><mml:mi>k</mml:mi><mml:mo>&#x2062;</mml:mo><mml:mi>g</mml:mi><mml:mo>&#x2062;</mml:mo><mml:mi>r</mml:mi><mml:mo>&#x2062;</mml:mo><mml:mi>o</mml:mi><mml:mo>&#x2062;</mml:mo><mml:mi>u</mml:mi><mml:mo>&#x2062;</mml:mo><mml:mi>n</mml:mi><mml:mo>&#x2062;</mml:mo><mml:mpadded width="+6.1pt"><mml:mi>d</mml:mi></mml:mpadded><mml:mo>&#x2062;</mml:mo><mml:mi>S</mml:mi><mml:mo>&#x2062;</mml:mo><mml:mi>U</mml:mi><mml:mo>&#x2062;</mml:mo><mml:msub><mml:mi>V</mml:mi><mml:mrow><mml:mtext>mean</mml:mtext></mml:mrow></mml:msub></mml:mrow></mml:mfrac></mml:math></inline-formula>.</p>
</sec>
<sec id="S2.SS4">
<title>Statistical analysis</title>
<p>Data was presented as mean (SD) unless otherwise specified.</p>
<p>Unmatched data were compared using Mann&#x2013;Whitney and Kruskal&#x2013;Wallis tests for quantitative data as appropriate. Wilcoxon and Friedman tests, and Bland&#x2013;Altman analyses were used to compare paired quantitative data as appropriate.</p>
<p>Statistical analysis and figure design were performed using XLSTAT software (XLSTAT 2019: Data Analysis and Statistical Solution for Microsoft Excel, Addinsoft). <italic>P</italic>-values &#x003C; 0.05 were considered statistically significant.</p>
</sec>
</sec>
<sec id="S3" sec-type="results">
<title>Results</title>
<sec id="S3.SS1">
<title>Population characteristics</title>
<p>Sixty-seven patients were included. Forty-four patients underwent their PET scans according to <italic>protocol_FixedDose</italic> and 32 according to <italic>protocol_WeightDose</italic>. Of note, nine patients underwent both protocols to monitor their disease over the inclusion period. Patients&#x2019; characteristics can be found in <xref ref-type="table" rid="T1">Table 1</xref>. Age, sex, BMI, PET indications and uptake delay were not different between <italic>protocol_FixedDose</italic> and <italic>protocol_WeightDose</italic> groups. The mean injected dose of 2.1 (0.4) MBq/kg per patient was significantly higher in the <italic>protocol_FixedDose</italic> group as compared to 1.5 (0.1) MBq/kg for the <italic>protocol_WeightDose</italic> group. Using the <italic>protocol_FixedDose</italic>, 93% of patients were injected with more than 1.5 MBq/kg, with an injected dose ranging from 1.4 MBq/kg in a severely obese patient (BMI = 41.2 kg/m<sup>2</sup>) to 3.0 MBq/kg injected in a normal weight patient (BMI = 19.1 kg/m<sup>2</sup>) (<xref ref-type="supplementary-material" rid="FS1">Supplementary Figure 1</xref>).</p>
<table-wrap position="float" id="T1">
<label>TABLE 1</label>
<caption><p>Patients and PET examination characteristics.</p></caption>
<table cellspacing="5" cellpadding="5" frame="box" rules="all">
<thead>
<tr>
<td valign="top" align="left" style="color:#ffffff;background-color: #7f8080;">Variables</td>
<td valign="top" align="center" style="color:#ffffff;background-color: #7f8080;"><italic>Protocol_FixedDose</italic><break/> (<italic>n</italic> = 44)</td>
<td valign="top" align="center" style="color:#ffffff;background-color: #7f8080;"><italic>Protocol_WeightDose</italic><break/> (<italic>n</italic> = 32)</td>
<td valign="top" align="center" style="color:#ffffff;background-color: #7f8080;"><italic>P</italic>-value<xref ref-type="table-fn" rid="t1fns1">&#x002A;</xref></td>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left" colspan="4" style="background-color: #dcdcdc;"><bold>Patient characteristics</bold></td>
</tr>
<tr>
<td valign="top" align="left" colspan="4" style="background-color: #dcdcdc;"><bold>Sex, <italic>n</italic> (%)</bold></td>
</tr>
<tr>
<td valign="top" align="left">&#x2022; Female</td>
<td valign="top" align="center">18 (40.9)</td>
<td valign="top" align="center">18 (54.5)</td>
<td valign="top" align="center">0.246</td>
</tr>
<tr>
<td valign="top" align="left">&#x2022; Male</td>
<td valign="top" align="center">26 (59.1)</td>
<td valign="top" align="center">14 (44.5)</td>
<td/>
</tr>
<tr>
<td valign="top" align="left">Age (yrs.), mean (SD)</td>
<td valign="top" align="center">65 (10)</td>
<td valign="top" align="center">63 (12)</td>
<td valign="top" align="center">0.521</td>
</tr>
<tr>
<td valign="top" align="left">BMI (kg/m<sup>2</sup>), mean (SD)</td>
<td valign="top" align="center">25.7 (4.6)</td>
<td valign="top" align="center">25.4 (7.4)</td>
<td valign="top" align="center">0.858</td>
</tr>
<tr>
<td valign="top" align="left" colspan="4" style="background-color: #dcdcdc;"><bold>PET indications, <italic>n</italic> (%)</bold></td>
</tr>
<tr>
<td valign="top" align="left">&#x2022; Staging</td>
<td valign="top" align="center">7 (15.9)</td>
<td valign="top" align="center">7 (21.9)</td>
<td valign="top" align="center">0.545</td>
</tr>
<tr>
<td valign="top" align="left">&#x2022; Disease monitoring</td>
<td valign="top" align="center">21 (47.7)</td>
<td valign="top" align="center">19 (59.4)</td>
<td/>
</tr>
<tr>
<td valign="top" align="left">&#x2022; Suspected recurrence</td>
<td valign="top" align="center">3 (6.8)</td>
<td valign="top" align="center">2 (6.2)</td>
<td/>
</tr>
<tr>
<td valign="top" align="left">&#x2022; Before PRRT</td>
<td valign="top" align="center">3 (6.8)</td>
<td valign="top" align="center">1 (3.1)</td>
<td/>
</tr>
<tr>
<td valign="top" align="left">&#x2022; Metabolic lesion characterization</td>
<td valign="top" align="center">10 (22.7)</td>
<td valign="top" align="center">3 (9.4)</td>
<td/>
</tr>
<tr>
<td valign="top" align="left" colspan="4" style="background-color: #dcdcdc;"><bold>PET examination characteristics</bold></td>
</tr>
<tr>
<td valign="top" align="left">Injected dose per patient (MBq), mean (SD)</td>
<td valign="top" align="center">151.6 (13.0)</td>
<td valign="top" align="center">111.8 (27.3)</td>
<td valign="top" align="center">&#x003C;0.0001</td>
</tr>
<tr>
<td valign="top" align="left">Injected dose per patient (MBq/kg), mean (SD)</td>
<td valign="top" align="center">2.1 (0.4)</td>
<td valign="top" align="center">1.5 (0.1)</td>
<td valign="top" align="center">&#x003C;0.0001</td>
</tr>
<tr>
<td valign="top" align="left">Uptake delay (min), mean (SD)</td>
<td valign="top" align="center">59 (5)</td>
<td valign="top" align="center">58 (3)</td>
<td valign="top" align="center">0.288</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="t1fns1"><p>&#x002A;Non-parametric Mann&#x2013;Whitney tests <italic>p</italic>-values, except for PET indications and sex for which Fisher exact tests were performed. BMI, body mass index; PRRT, peptide receptor radionuclide therapy.</p></fn>
</table-wrap-foot>
</table-wrap>
</sec>
<sec id="S3.SS2">
<title>Comparison of <italic>protocol_FixedDose</italic> and <italic>protocol_WeightDose</italic></title>
<p>Two patients in the <italic>protocol_FixedDose</italic> group had diffuse liver metastatic involvement that did not allow their hepatic CV to be calculated. Overall, <italic>protocol_WeightDose</italic> led to noisier images with higher liver, vascular and muscular CVs (<xref ref-type="fig" rid="F1">Figure 1</xref>). The mean liver CVs were equal to 15.57% &#x00B1; 4.32 vs. 13.04% &#x00B1; 3.51 for <italic>protocol_WeightDose</italic> and <italic>protocol_FixedDose</italic>, respectively (<italic>p</italic> = 0.018). Mean vascular CVs were 28.67% &#x00B1; 8.65 vs. 22.25% &#x00B1; 10.37 for <italic>protocol_WeightDose</italic> and <italic>Protocol_FixedDose</italic>, respectively (<italic>p</italic> = 0.0003). Mean muscular CVs were 35.87% &#x00B1; 12.46 vs. 26.86% &#x00B1; 8.63 for <italic>protocol_WeightDose</italic> and <italic>Protocol_FixedDose</italic>, respectively (<italic>p</italic> = 0.0.005).</p>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption><p>Image noise analysis. &#x002A;Paired Wilcoxon tests were used to compare <italic>protocol_WeightDose</italic> and protocol_Weight dose<sup>AI</sup> data: Otherwise Mann&#x2013;Whitney tests were used.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmed-10-1137514-g001.tif"/>
</fig>
</sec>
<sec id="S3.SS3">
<title>Gaussian filter width determination for the <italic>protocol_WeightDose</italic><sup>Gaussian</sup></title>
<p>The GPF width to be applied to the <italic>protocol_WeightDose</italic> acquisitions was determined from the NEMA-NU2 phantom acquisitions to ensure equivalent noise as compared to the <italic>protocol_FixedDose</italic>. A 2.6 mm GPF width was highlighted by dichotomization, applied and used thereafter. NEMA-NU2 CVs were equal to 23.15, 27.63 and 23.30% for <italic>protocol_FixedDose, protocol_WeightDose</italic>, and <italic>Protocol_WeightDose<sup>Gaussian</sup></italic>, respectively.</p>
</sec>
<sec id="S3.SS4">
<title>Performances of <italic>protocol_WeightDose</italic><sup>AI</sup> and <italic>protocol_WeightDose</italic><sup>Gaussian</sup></title>
<sec id="S3.SS4.SSS1">
<title>Image quality: Noise and contrast</title>
<p>On paired comparison, <italic>protocol_WeightDose<sup>AI</sup></italic> led to less noisy images than <italic>protocol_WeightDose</italic> with lower liver, vascular and muscular CVs (<xref ref-type="fig" rid="F1">Figure 1</xref>). Mean liver, vascular and muscular CVs were 11.42% &#x00B1; 3.05 vs. 15.57% &#x00B1; 4.32 (<italic>p</italic> &#x003C; 0.0001), 16.62% &#x00B1; 6.40 vs. 28.67% &#x00B1; 8.65 (<italic>p</italic> &#x003C; 0.0001) and 23.88% &#x00B1; 10.58 vs. 35.87% &#x00B1; 12.46 (<italic>p</italic> &#x003C; 0.0001), respectively. Moreover, mean liver, vascular and muscular CVs using <italic>protocol_WeightDose<sup>AI</sup></italic> were slightly lower from those of <italic>protocol_FixedDose</italic> (<xref ref-type="fig" rid="F1">Figure 1</xref>).</p>
<p>On paired comparison, <italic>protocol_WeightDose<sup>Gaussian</sup></italic> also led to less noisy images than <italic>protocol_WeightDose</italic> with lower liver, vascular and muscular CVs (<xref ref-type="fig" rid="F1">Figure 1</xref>). <italic>Protocol_WeightDose<sup>Gaussian</sup></italic> mean liver, vascular and muscular CVs were 10.92% &#x00B1; 3.00 (<italic>p</italic> &#x003C; 0.0001), 20.50% &#x00B1; 5.12 (<italic>p</italic> = 0.002) and 25.49% &#x00B1; 7.14 (<italic>p</italic> = 0.0001), respectively. The mean liver CV obtained with the <italic>protocol_WeightDose<sup>Gaussian</sup></italic> protocol was also lower than with the <italic>protocol_FixedDose</italic>. However, mean vascular and muscular CVs were not different (<xref ref-type="fig" rid="F1">Figure 1</xref>). There were no significant differences between mean liver and muscular CVs of the <italic>protocol_WeightDose<sup>AI</sup> and</italic> the <italic>protocol_WeightDose<sup>Gaussian</sup>.</italic> In contrast, the mean vascular CV of the <italic>protocol_WeightDose<sup>Gaussian</sup></italic> was higher than that of the <italic>protocol_WeightDose<sup>AI</sup></italic>, <italic>p</italic> = 0.018 (<xref ref-type="fig" rid="F1">Figure 1</xref>).</p>
<p>On paired comparison, tumour-to-background ratios and tumour-to-liver ratios were lower when using <italic>protocol_WeightDose<sup>AI</sup></italic> with a mean tumour-to-background ratio of 6.78 &#x00B1; 3.49 vs. 7.57 &#x00B1; 4.73 for the <italic>protocol_WeightDose</italic> (<italic>p</italic> = 0.04) and a mean tumour-to-liver ratio of 5.96 &#x00B1; 5.43 vs. 6.77 &#x00B1; 6.19 (<italic>p</italic> = 0.0001). Using the <italic>protocol_WeightDose<sup>Gaussian</sup></italic> both these ratios were also lower than those obtained with the <italic>protocol_WeightDose</italic>, and even lower than those obtained with the <italic>protocol_WeightDose<sup>AI</sup></italic>. The mean tumour-to-background ratio was equal to 5.60 &#x00B1; 2.95 (<italic>p</italic> &#x003C; 0.0001 as compared to <italic>protocol_WeightDose</italic> and <italic>p</italic> = 0.013 as compared to protocol_WeightDose<sup>AI</sup>) and the mean tumour-to-liver ratio was equal to 5.22 &#x00B1; 4.93 (<italic>p</italic> &#x003C; 0.0001 as compared to <italic>protocol_WeightDose</italic> and <italic>p</italic> = 0.02 as compared to protocol_WeightDose<sup>AI</sup>).</p>
</sec>
<sec id="S3.SS4.SSS2">
<title>Lesions quantitative values</title>
<p>Metabolic tumour volumes, SUV<sub>max</sub> and SUV<sub>mean</sub> of the hottest lesion were different between <italic>protocol_WeightDose</italic> and <italic>protocol_WeightDose<sup>AI</sup></italic> on paired comparison. Similar findings were observed between <italic>protocol_WeightDose</italic> and <italic>protocol_WeightDose<sup>Gaussian</sup></italic> (<xref ref-type="fig" rid="F2">Figure 2</xref>).</p>
<fig id="F2" position="float">
<label>FIGURE 2</label>
<caption><p>Paired comparison of <italic>protocol_WeightDose, protocol_WeightDose<sup>AI</sup></italic>, and <italic>protocol_WeightDose<sup>Gaussian</sup></italic> quantitative values.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmed-10-1137514-g002.tif"/>
</fig>
<p>Metabolic tumour volumes were significantly higher when using <italic>protocol_WeightDose<sup>AI</sup></italic> with a mean MTV of 9.11 &#x00B1; 20.26 vs. 8.46 &#x00B1; 18.87 for the <italic>protocol_WeightDose</italic> (<italic>p</italic> = 0.044). <italic>Protocol_WeightDose<sup>Gaussian</sup></italic> led to even higher MTV values (10.41 &#x00B1; 21.44) with a <italic>p</italic>-value &#x003C; 0.0001 as compared to <italic>protocol_WeightDose</italic> and equal to 0.001 as compared to <italic>protocol_WeightDose<sup>AI</sup></italic>.</p>
<p>SUV<sub>max</sub> and SUV<sub>mean</sub> were lower for the <italic>protocol_WeightDose <sup>AI</sup></italic> with a mean SUV<sub>max</sub> of 66.65 &#x00B1; 71.97 vs. 69.76 &#x00B1; 77.29 for the <italic>protocol_WeightDose</italic> (<italic>p</italic> = 0.09) and a mean SUV<sub>mean</sub> equal to 39.67 &#x00B1; 42.95 vs. 41.72 &#x00B1; 46.42 for the <italic>protocol_WeightDose</italic> (<italic>p</italic> = 0.044) (<xref ref-type="fig" rid="F2">Figure 2</xref>). <italic>Protocol_WeightDose<sup>Gaussian</sup></italic> led to even lower SUV values than protocol <italic>protocol_WeightDose <sup>AI</sup></italic>: 54.06 &#x00B1; 59.11 for SUV<sub>max</sub> (<italic>p</italic> = 0.002) and 32.32 &#x00B1; 35.76 for SUV<sub>mean</sub> (<italic>p</italic> = 0.001).</p>
<p>The mean % differences in MTV, SUV<sub>max</sub> and SUV<sub>mean</sub> before and after denoising by application of the <italic>protocol_WeightDose<sup>AI</sup></italic> were low, equal to +11.14% (95% CI = 4.84&#x2013;17.43), &#x2212;3.92% (95% CI = &#x2212;6.25 to &#x2212;1.59) and &#x2212;4.32% (95% CI = &#x2212;6.98 to &#x2212;1.66), respectively (<xref ref-type="fig" rid="F2">Figure 2</xref>). These mean % differences were higher by using the <italic>Protocol_WeightDose<sup>Gaussian</sup></italic>: + 42.69% (95% CI = 25.23&#x2013;60.15) for MTV, &#x2212;24.66% (95% CI = &#x2212;33.02 to &#x2212;16.29) for SUV<sub>max</sub> and &#x2212;25.08 (95% CI = &#x2212;30.00 to &#x2212;20.15%) for SUV<sub>mean</sub>.</p>
<p>Side-by-side representative images of a patient who underwent all four protocols during the inclusion period are displayed in <xref ref-type="fig" rid="F3">Figure 3</xref>. Complete data for the nine patients who had all protocols are reported in <xref ref-type="supplementary-material" rid="TS1">Supplementary Table 1</xref>.</p>
<fig id="F3" position="float">
<label>FIGURE 3</label>
<caption><p>Representative images of a patient who underwent all four protocols during the inclusion period. A total of 77-year-old man of normal weight (BMI = 21.3 kg/m<sup>2</sup>) with a well-differentiated metastatic pancreatic neuroendocrine tumour (grade 1, Ki 67 &#x003C; 1%). Injected doses were 158 MBq (2.4 MBq/kg) for <italic>protocol_FixedDose</italic> and 86 MBq (1.3 MBq/kg) for <italic>protocol_WeightDose</italic>, <italic>protocol_WeightDose<sup>AI</sup></italic> and protocol_<italic>WeightDose</italic><sup>Gaussian</sup>. All images are scaled to the same SUV<sub>max</sub>.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmed-10-1137514-g003.tif"/>
</fig>
</sec>
</sec>
</sec>
<sec id="S4" sec-type="discussion">
<title>Discussion</title>
<p>This study shows that the degradation of PET image quality due to a reduction in injected dose at the end of the <sup>68</sup>Ge/<sup>68</sup>Ga generator lifetime can be counterbalanced effectively by using AI-based PET denoising.</p>
<p>The EANM guidelines recommend an administered activity ranging from 100 to 200 Mbq, meaning that both fixed dose and ponderal dose strategies can be considered (<xref ref-type="bibr" rid="B16">16</xref>). To date, these two strategies have not been compared and the use of either one is at the discretion of each nuclear medicine department.</p>
<p>In our center, at the start of the generator lifetime using the <italic>protocol_FixedDose</italic>, almost all patients were injected with more than 1.5 MBq/kg of <sup>68</sup>Ga-DOTATOC. This explains the better image quality parameters observed with <italic>Protocol_FixedDose</italic> than with <italic>Protocol_WeightDose.</italic> The use of <italic>Protocol_WeightDose<sup>AI</sup></italic> or <italic>Protocol_WeightDose<sup>Gaussian</sup></italic> led to an increase in image quality comparable to that of our former <italic>protocol_FixedDose</italic> with regard to image noise. To achieve comparable noise image quality performances at the end of the generator lifetime as per <italic>Protocol_FixedDose</italic> taken as reference in the present study, there are four possible solutions: (i) increasing the injected dose to 2.0 MBq/kg, which corresponds to the mean injected dose when using <italic>Protocol_FixedDose</italic>; (ii) increasing the PET acquisition time to compensate for the lower injected dose; (iii) adapting the reconstruction parameters, i.e., applying a Gaussian Filter; or (iv) exploring external solutions such as AI-based post-reconstruction PET denoising software.</p>
<p>Increasing the injected dose does not seem feasible as the eluted dose will inevitably decrease over time. Furthermore, it is always preferable for the patient&#x2019;s sake to decrease rather than increase the injected dose (<xref ref-type="bibr" rid="B8">8</xref>, <xref ref-type="bibr" rid="B9">9</xref>). Increasing the acquisition time seems illusory in busy PET units, especially considering the short and therefore restrictive half-life of <sup>68</sup>Ga. The use of a Gaussian filter during reconstruction can certainly solve the problem of image noise but is detrimental to the quantitative values of the lesions. In the present study, the tumour volumes are overestimated on average by more than 40% and the SUVs underestimated by more than 20%, which does not seem tolerable in clinical settings. This is consistent with previous results obtained with FDG-PET (<xref ref-type="bibr" rid="B12">12</xref>). Thus, applying PET denoising software to a <italic>Protocol_WeightDose</italic> would provide good noise quality and quantitatively less altered <sup>68</sup>Ga-DOTATOC PET/CT images acquired rapidly and at &#x201C;low-dose.&#x201D; From an economic point of view, the costs of using an AI-based PET denoising solution should offset the costs related to the decreasing yield of the generator. As more and more <sup>68</sup>Ga-labeled tracers will probably be commercialized in the future, the value of AI will increase.</p>
<p>Previous work from our group on AI-based PET denoising in a large series of FDG PET scans showed the reassuringly high concordance rate in lesion detection between conventional and AI-processed PET images in the same patient (<xref ref-type="bibr" rid="B11">11</xref>). Therefore, the primary aim of PET imaging, which is lesion detection with high sensitivity, does not seem to be jeopardized by AI. Although FDG- and <sup>68</sup>Ga-labeled tracers target different diseases and show differences in biodistribution, we feel it is safe to extrapolate the detection rate obtained in AI-processed FDG PET scans to AI-processed <sup>68</sup>Ga PET scans, as the tumour contrast in the latter is often much higher than in the former. Also, the article by Liu et al. focusing on a cross-tracer and cross-protocol deep transfer learning method for noise reduction indicated that the network trained with FDG datasets can effectively reduce noise in low-dose PET images from less commonly used tracers (i.e., <sup>68</sup>Ga-DOTATATE) while preserving diagnostic information (<xref ref-type="bibr" rid="B18">18</xref>).</p>
<p>We used two methods to evaluate tumour contrast: The tumour-to-background ratio using a doughnut-shaped VOI and the tumour-to-liver ratio. For the doughnut-shaped VOI, the choice of the tumour-contouring method was crucial to ensure the reliability of the resulting background noise measurements. We chose to use a thresholding value set in reference to SUV<sub>max</sub>, which was previously demonstrated in the study by Reddy et al. (<xref ref-type="bibr" rid="B19">19</xref>) to be the most accurate measurement when compared to morphological volumes. Beyond tumour detectability, one must also take into account the risk of false positive results which increases with the noise in the image. In particular, an increase in liver background noise can easily lead to the overestimation of hepatic metastatic involvement by taking noise for small lesions, especially in patients followed for neuroendocrine tumours with high hepatic metastatic risk. <xref ref-type="fig" rid="F3">Figure 3</xref> illustrates this issue nicely.</p>
<p>We acknowledge our study has limitations. First, the use of semi-quantitative parameters for <sup>68</sup>Ga-peptide imaging has some limitations, although it is the most commonly used method in practice (<xref ref-type="bibr" rid="B20">20</xref>, <xref ref-type="bibr" rid="B21">21</xref>). One of the main limitations is that it is subject to variations in PET device sensitivity, image acquisition parameters and patient-specific factors that can lead to inaccuracies in quantification (<xref ref-type="bibr" rid="B22">22</xref>). Another limitation is that it relies on the assumption that the tracer uptake is proportional to the density of the target receptor, which may not always be the case (<xref ref-type="bibr" rid="B23">23</xref>, <xref ref-type="bibr" rid="B24">24</xref>). Secondly, this is a single-center study on <sup>68</sup>Ga-DOTATOC PET images only. Although the cohort was small, it covers the lifetime of one generator, i.e., a period of approximately 1 year, during which all patients were included. The robustness of our findings need to be investigated in a multicenter study on different PET systems. Thirdly, only the <italic>protocol_WeightDose</italic> PET scans were AI-processed, leading to a limited number of pairwise comparisons. However, at the start of the generator lifetime, we did not feel the need to use AI processing in view of the good image quality of the <italic>protocol_FixedDose</italic> PET scans. The need to improve image quality became evident at the end of generator life. Finally, we could not properly evaluate the SUV<sub>peak</sub> data because the small target lesions occurring in 57.7% of <italic>protocol_FixedDose</italic> patients (15/26) and 81.8% of <italic>protocol_WeightDose</italic> and <italic>protocol_WeightDose<sup>AI</sup></italic> patients (18/22) (<xref ref-type="bibr" rid="B25">25</xref>) were not sufficiently measurable. This was because most target lesions were small with a mean MTV around only 9cc for <italic>protocol_WeightDose</italic> and <italic>protocol_WeightDose<sup>AI</sup></italic>.</p>
</sec>
<sec id="S5" sec-type="conclusion">
<title>Conclusion</title>
<p>The degradation of PET image quality due to a reduction of injected dose at the end of the <sup>68</sup>Ge/<sup>68</sup>Ga generator lifespan can be counterbalanced effectively by using an AI-based PET denoising solution.</p>
</sec>
<sec id="S6" sec-type="data-availability">
<title>Data availability statement</title>
<p>The datasets generated during and/or analyzed during the current study are available from the corresponding author on reasonable request.</p>
</sec>
<sec id="S7" sec-type="ethics-statement">
<title>Ethics statement</title>
<p>The studies involving human participants were reviewed and approved by the Ethics Committee of Centre Fran&#x00E7;ois Baclesse. The patients/participants provided their written informed consent to participate in this study.</p>
</sec>
<sec id="S8" sec-type="author-contributions">
<title>Author contributions</title>
<p>EQ and CL performed the image reading and wrote the first draft of the manuscript. All authors commented on previous versions of the manuscript, read, and approved the final manuscript, contributed to the study&#x2019;s conception and design, material preparation, data collection, and analysis were performed.</p>
</sec>
</body>
<back>
<ack>
<p>Ray Cooke is thanked for copyediting the manuscript. We benefitted from a 1-month free trial period of SubtlePET&#x2122;.</p>
</ack>
<sec id="S10" sec-type="COI-statement">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec id="S11" sec-type="disclaimer">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<sec id="S12" sec-type="supplementary-material">
<title>Supplementary material</title>
<p>The Supplementary Material for this article can be found online at: <ext-link ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/fmed.2023.1137514/full#supplementary-material">https://www.frontiersin.org/articles/10.3389/fmed.2023.1137514/full#supplementary-material</ext-link></p>
<supplementary-material xlink:href="Table_1.DOCX" id="TS1" mimetype="application/vnd.openxmlformats-officedocument.wordprocessingml.document" xmlns:xlink="http://www.w3.org/1999/xlink"/>
<supplementary-material xlink:href="Image_1.TIF" id="FS1" mimetype="image/tiff" xmlns:xlink="http://www.w3.org/1999/xlink">
<label>Supplementary Figure 1</label>
<caption><p>Injected dose scatter plot according to BMI for the 44 patients in <italic>Protocol_FixedDose</italic> group.</p></caption>
</supplementary-material>
</sec>
<fn-group>
<title>Abbreviations</title>
<fn fn-type="abbr">
<p>PET, positron emission tomography; AI, artificial intelligence; SUV, standardized uptake value; MTV, metabolic tumour volume; NETs, NeuroEndocrine tumours; VOI, volume of interest; GPF, Gaussian post filter; CV, coefficient of variation; BMI, body mass index; PSMA, prostate-specific membrane antigen; FDA, food and drug administration; CE, European conformity; SD, standard deviation; FDG, fluorodeoxyglucose.</p></fn>
</fn-group>
<ref-list>
<title>References</title>
<ref id="B1"><label>1.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Singh</surname> <given-names>S</given-names></name> <name><surname>Poon</surname> <given-names>R</given-names></name> <name><surname>Wong</surname> <given-names>R</given-names></name> <name><surname>Metser</surname> <given-names>U</given-names></name></person-group>. <article-title>68Ga PET imaging in patients with neuroendocrine tumors: a systematic review and meta-analysis.</article-title> <source><italic>Clin Nucl Med.</italic></source> (<year>2018</year>) <volume>43</volume>:<fpage>802</fpage>&#x2013;<lpage>10</lpage>. <pub-id pub-id-type="doi">10.1097/RLU.0000000000002276</pub-id> <pub-id pub-id-type="pmid">30247209</pub-id></citation></ref>
<ref id="B2"><label>2.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hofman</surname> <given-names>M</given-names></name> <name><surname>Iravani</surname> <given-names>A</given-names></name></person-group>. <article-title>Gallium-68 prostate-specific membrane antigen PET imaging.</article-title> <source><italic>PET Clin.</italic></source> (<year>2017</year>) <volume>12</volume>:<fpage>219</fpage>&#x2013;<lpage>34</lpage>. <pub-id pub-id-type="doi">10.1016/j.cpet.2016.12.004</pub-id> <pub-id pub-id-type="pmid">28267455</pub-id></citation></ref>
<ref id="B3"><label>3.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hicks</surname> <given-names>R</given-names></name> <name><surname>Kwekkeboom</surname> <given-names>D</given-names></name> <name><surname>Krenning</surname> <given-names>E</given-names></name> <name><surname>Bodei</surname> <given-names>L</given-names></name> <name><surname>Grozinsky-Glasberg</surname> <given-names>S</given-names></name> <name><surname>Arnold</surname> <given-names>R</given-names></name><etal/></person-group> <article-title>ENETS consensus guidelines for the standards of care in neuroendocrine neoplasia: peptide receptor radionuclide therapy with radiolabeled somatostatin analogues.</article-title> <source><italic>Neuroendocrinology.</italic></source> (<year>2017</year>) <volume>105</volume>:<fpage>295</fpage>&#x2013;<lpage>309</lpage>. <pub-id pub-id-type="doi">10.1159/000475526</pub-id> <pub-id pub-id-type="pmid">28402980</pub-id></citation></ref>
<ref id="B4"><label>4.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ta&#x00EF;eb</surname> <given-names>D</given-names></name> <name><surname>Hicks</surname> <given-names>R</given-names></name> <name><surname>Hindi&#x00E9;</surname> <given-names>E</given-names></name> <name><surname>Guillet</surname> <given-names>B</given-names></name> <name><surname>Avram</surname> <given-names>A</given-names></name> <name><surname>Ghedini</surname> <given-names>P</given-names></name><etal/></person-group> <article-title>European association of nuclear medicine practice guideline/society of nuclear medicine and molecular imaging procedure standard 2019 for radionuclide imaging of phaeochromocytoma and paraganglioma.</article-title> <source><italic>Eur J Nucl Med Mol Imaging.</italic></source> (<year>2019</year>) <volume>46</volume>:<fpage>2112</fpage>&#x2013;<lpage>37</lpage>. <pub-id pub-id-type="doi">10.1007/s00259-019-04398-1</pub-id> <pub-id pub-id-type="pmid">31254038</pub-id></citation></ref>
<ref id="B5"><label>5.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Howe</surname> <given-names>J</given-names></name> <name><surname>Cardona</surname> <given-names>K</given-names></name> <name><surname>Fraker</surname> <given-names>D</given-names></name> <name><surname>Kebebew</surname> <given-names>E</given-names></name> <name><surname>Untch</surname> <given-names>B</given-names></name> <name><surname>Wang</surname> <given-names>Y</given-names></name><etal/></person-group> <article-title>The surgical management of small bowel neuroendocrine tumors: consensus guidelines of the North American neuroendocrine tumor society.</article-title> <source><italic>Pancreas.</italic></source> (<year>2017</year>) <volume>46</volume>:<fpage>715</fpage>&#x2013;<lpage>31</lpage>. <pub-id pub-id-type="doi">10.1097/MPA.0000000000000846</pub-id> <pub-id pub-id-type="pmid">28609357</pub-id></citation></ref>
<ref id="B6"><label>6.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ambrosini</surname> <given-names>V</given-names></name> <name><surname>Kunikowska</surname> <given-names>J</given-names></name> <name><surname>Baudin</surname> <given-names>E</given-names></name> <name><surname>Bodei</surname> <given-names>L</given-names></name> <name><surname>Bouvier</surname> <given-names>C</given-names></name> <name><surname>Capdevila</surname> <given-names>J</given-names></name><etal/></person-group> <article-title>Consensus on molecular imaging and theranostics in neuroendocrine neoplasms.</article-title> <source><italic>Eur J Cancer.</italic></source> (<year>2021</year>) <volume>146</volume>:<fpage>56</fpage>&#x2013;<lpage>73</lpage>. <pub-id pub-id-type="doi">10.1016/j.ejca.2021.01.008</pub-id> <pub-id pub-id-type="pmid">33588146</pub-id></citation></ref>
<ref id="B7"><label>7.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Liu</surname> <given-names>J</given-names></name> <name><surname>Malekzadeh</surname> <given-names>M</given-names></name> <name><surname>Mirian</surname> <given-names>N</given-names></name> <name><surname>Song</surname> <given-names>T</given-names></name> <name><surname>Liu</surname> <given-names>C</given-names></name> <name><surname>Dutta</surname> <given-names>J</given-names></name></person-group>. <article-title>Artificial intelligence-based image enhancement in PET imaging: noise reduction and resolution enhancement.</article-title> <source><italic>PET Clin.</italic></source> (<year>2021</year>) <volume>16</volume>:<fpage>553</fpage>&#x2013;<lpage>76</lpage>. <pub-id pub-id-type="doi">10.1016/j.cpet.2021.06.005</pub-id> <pub-id pub-id-type="pmid">34537130</pub-id></citation></ref>
<ref id="B8"><label>8.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chaudhari</surname> <given-names>A</given-names></name> <name><surname>Mittra</surname> <given-names>E</given-names></name> <name><surname>Davidzon</surname> <given-names>G</given-names></name> <name><surname>Gulaka</surname> <given-names>P</given-names></name> <name><surname>Gandhi</surname> <given-names>H</given-names></name> <name><surname>Brown</surname> <given-names>A</given-names></name><etal/></person-group> <article-title>Low-count whole-body PET with deep learning in a multicenter and externally validated study.</article-title> <source><italic>NPJ Digit Med.</italic></source> (<year>2021</year>) <volume>4</volume>:<issue>127</issue>. <pub-id pub-id-type="doi">10.1038/s41746-021-00497-2</pub-id> <pub-id pub-id-type="pmid">34426629</pub-id></citation></ref>
<ref id="B9"><label>9.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Katsari</surname> <given-names>K</given-names></name> <name><surname>Penna</surname> <given-names>D</given-names></name> <name><surname>Arena</surname> <given-names>V</given-names></name> <name><surname>Polverari</surname> <given-names>G</given-names></name> <name><surname>Ianniello</surname> <given-names>A</given-names></name> <name><surname>Italiano</surname> <given-names>D</given-names></name><etal/></person-group> <article-title>Artificial intelligence for reduced dose 18F-FDG PET examinations: a real-world deployment through a standardized framework and business case assessment.</article-title> <source><italic>EJNMMI Phys.</italic></source> (<year>2021</year>) <volume>8</volume>:<issue>25</issue>. <pub-id pub-id-type="doi">10.1186/s40658-021-00374-7</pub-id> <pub-id pub-id-type="pmid">33687602</pub-id></citation></ref>
<ref id="B10"><label>10.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bonardel</surname> <given-names>G</given-names></name> <name><surname>Dupont</surname> <given-names>A</given-names></name> <name><surname>Decazes</surname> <given-names>P</given-names></name> <name><surname>Queneau</surname> <given-names>M</given-names></name> <name><surname>Modzelewski</surname> <given-names>R</given-names></name> <name><surname>Coulot</surname> <given-names>J</given-names></name><etal/></person-group> <article-title>Clinical and phantom validation of a deep learning based denoising algorithm for F-18-FDG PET images from lower detection counting in comparison with the standard acquisition.</article-title> <source><italic>EJNMMI Phys.</italic></source> (<year>2022</year>) <volume>9</volume>:<issue>36</issue>. <pub-id pub-id-type="doi">10.1186/s40658-022-00465-z</pub-id> <pub-id pub-id-type="pmid">35543894</pub-id></citation></ref>
<ref id="B11"><label>11.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Weyts</surname> <given-names>K</given-names></name> <name><surname>Lasnon</surname> <given-names>C</given-names></name> <name><surname>Ciappuccini</surname> <given-names>R</given-names></name> <name><surname>Lequesne</surname> <given-names>J</given-names></name> <name><surname>Corroyer-Dulmont</surname> <given-names>A</given-names></name> <name><surname>Quak</surname> <given-names>E</given-names></name><etal/></person-group> <article-title>Artificial intelligence-based PET denoising could allow a two-fold reduction in [(18)F]FDG PET acquisition time in digital PET/CT.</article-title> <source><italic>Eur J Nucl Med Mol Imaging</italic></source> (<year>2022</year>) <volume>49</volume>:<fpage>3750</fpage>&#x2013;<lpage>60</lpage>. <pub-id pub-id-type="doi">10.1007/s00259-022-05800-1</pub-id> <pub-id pub-id-type="pmid">35593925</pub-id></citation></ref>
<ref id="B12"><label>12.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jaudet</surname> <given-names>C</given-names></name> <name><surname>Weyts</surname> <given-names>K</given-names></name> <name><surname>Lechervy</surname> <given-names>A</given-names></name> <name><surname>Batalla</surname> <given-names>A</given-names></name> <name><surname>Bardet</surname> <given-names>S</given-names></name> <name><surname>Corroyer-Dulmont</surname> <given-names>A</given-names></name></person-group>. <article-title>The impact of artificial intelligence CNN based denoising on FDG PET radiomics.</article-title> <source><italic>Front Oncol.</italic></source> (<year>2021</year>) <volume>11</volume>:<issue>692973</issue>. <pub-id pub-id-type="doi">10.3389/fonc.2021.692973</pub-id> <pub-id pub-id-type="pmid">34504782</pub-id></citation></ref>
<ref id="B13"><label>13.</label><citation citation-type="journal"><collab>Subtle Medical.</collab> <source><italic>Subtlepet.</italic></source> (<year>2018</year>). Available online at: <ext-link ext-link-type="uri" xlink:href="https://subtlemedical.com/usa/subtlepet/">https://subtlemedical.com/usa/subtlepet/</ext-link> (<comment>accessed February 15, 2023</comment>).</citation></ref>
<ref id="B14"><label>14.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pain</surname> <given-names>C</given-names></name> <name><surname>Egan</surname> <given-names>G</given-names></name> <name><surname>Chen</surname> <given-names>Z</given-names></name></person-group>. <article-title>Deep learning-based image reconstruction and post-processing methods in positron emission tomography for low-dose imaging and resolution enhancement.</article-title> <source><italic>Eur J Nucl Med Mol Imaging.</italic></source> (<year>2022</year>) <volume>49</volume>:<fpage>3098</fpage>&#x2013;<lpage>118</lpage>. <pub-id pub-id-type="doi">10.1007/s00259-022-05746-4</pub-id> <pub-id pub-id-type="pmid">35312031</pub-id></citation></ref>
<ref id="B15"><label>15.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gavriilidis</surname> <given-names>P</given-names></name> <name><surname>Koole</surname> <given-names>M</given-names></name> <name><surname>Annunziata</surname> <given-names>S</given-names></name> <name><surname>Mottaghy</surname> <given-names>F</given-names></name> <name><surname>Wierts</surname> <given-names>R</given-names></name></person-group>. <article-title>Positron range corrections and denoising techniques for gallium-68 PET imaging: a literature review.</article-title> <source><italic>Diagnostics.</italic></source> (<year>2022</year>) <volume>12</volume>:<issue>2335</issue>. <pub-id pub-id-type="doi">10.3390/diagnostics12102335</pub-id> <pub-id pub-id-type="pmid">36292023</pub-id></citation></ref>
<ref id="B16"><label>16.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Virgolini</surname> <given-names>I</given-names></name> <name><surname>Ambrosini</surname> <given-names>V</given-names></name> <name><surname>Bomanji</surname> <given-names>J</given-names></name> <name><surname>Baum</surname> <given-names>R</given-names></name> <name><surname>Fanti</surname> <given-names>S</given-names></name> <name><surname>Gabriel</surname> <given-names>M</given-names></name><etal/></person-group> <article-title>Procedure guidelines for PET/CT tumour imaging with 68Ga-DOTA-conjugated peptides: 68Ga-DOTA-TOC, 68Ga-DOTA-NOC, 68Ga-DOTA-TATE.</article-title> <source><italic>Eur J Nucl Med Mol Imaging.</italic></source> (<year>2010</year>) <volume>37</volume>:<fpage>2004</fpage>&#x2013;<lpage>10</lpage>. <pub-id pub-id-type="doi">10.1007/s00259-010-1512-3</pub-id> <pub-id pub-id-type="pmid">20596866</pub-id></citation></ref>
<ref id="B17"><label>17.</label><citation citation-type="journal"><collab>NEMA.</collab> <source><italic>Association, N.E.M., NEMA standards publication NU-2 2012 performance measurements of positron emission tomographs.</italic></source> <publisher-loc>Rosslyn</publisher-loc>: <publisher-name>NEMA</publisher-name> (<year>2012</year>).</citation></ref>
<ref id="B18"><label>18.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Liu</surname> <given-names>H</given-names></name> <name><surname>Wu</surname> <given-names>J</given-names></name> <name><surname>Lu</surname> <given-names>W</given-names></name> <name><surname>Onofrey</surname> <given-names>J</given-names></name> <name><surname>Liu</surname> <given-names>Y</given-names></name> <name><surname>Liu</surname> <given-names>C</given-names></name></person-group>. <article-title>Noise reduction with cross-tracer and cross-protocol deep transfer learning for low-dose PET.</article-title> <source><italic>Phys Med Biol.</italic></source> (<year>2020</year>) <volume>65</volume>:<issue>185006</issue>. <pub-id pub-id-type="doi">10.1088/1361-6560/abae08</pub-id> <pub-id pub-id-type="pmid">32924973</pub-id></citation></ref>
<ref id="B19"><label>19.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Reddy</surname> <given-names>R</given-names></name> <name><surname>Schmidtlein</surname> <given-names>C</given-names></name> <name><surname>Giancipoli</surname> <given-names>R</given-names></name> <name><surname>Mauguen</surname> <given-names>A</given-names></name> <name><surname>LaFontaine</surname> <given-names>D</given-names></name> <name><surname>Schoder</surname> <given-names>H</given-names></name><etal/></person-group> <article-title>The quest for an accurate functional tumor volume with (68)Ga-DOTATATE PET/CT.</article-title> <source><italic>J Nucl Med.</italic></source> (<year>2021</year>) <volume>121</volume>:<issue>262782</issue>. <pub-id pub-id-type="doi">10.2967/jnumed.121.262782</pub-id> <pub-id pub-id-type="pmid">34772795</pub-id></citation></ref>
<ref id="B20"><label>20.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kratochwil</surname> <given-names>C</given-names></name> <name><surname>Stefanova</surname> <given-names>M</given-names></name> <name><surname>Mavriopoulou</surname> <given-names>E</given-names></name> <name><surname>Holland-Letz</surname> <given-names>T</given-names></name> <name><surname>Dimitrakopoulou-Strauss</surname> <given-names>A</given-names></name> <name><surname>Afshar-Oromieh</surname> <given-names>A</given-names></name><etal/></person-group> <article-title>SUV of [68Ga]DOTATOC-PET/CT predicts response probability of PRRT in neuroendocrine tumors.</article-title> <source><italic>Mol Imaging Biol.</italic></source> (<year>2015</year>) <volume>17</volume>:<fpage>313</fpage>&#x2013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1007/s11307-014-0795-3</pub-id> <pub-id pub-id-type="pmid">25319765</pub-id></citation></ref>
<ref id="B21"><label>21.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sharma</surname> <given-names>R</given-names></name> <name><surname>Wang</surname> <given-names>W</given-names></name> <name><surname>Yusuf</surname> <given-names>S</given-names></name> <name><surname>Evans</surname> <given-names>J</given-names></name> <name><surname>Ramaswami</surname> <given-names>R</given-names></name> <name><surname>Wernig</surname> <given-names>F</given-names></name><etal/></person-group> <article-title>(68)Ga-DOTATATE PET/CT parameters predict response to peptide receptor radionuclide therapy in neuroendocrine tumours.</article-title> <source><italic>Radiother Oncol.</italic></source> (<year>2019</year>) <volume>141</volume>:<fpage>108</fpage>&#x2013;<lpage>15</lpage>. <pub-id pub-id-type="doi">10.1016/j.radonc.2019.09.003</pub-id> <pub-id pub-id-type="pmid">31542317</pub-id></citation></ref>
<ref id="B22"><label>22.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Huizing</surname> <given-names>D</given-names></name> <name><surname>Koopman</surname> <given-names>D</given-names></name> <name><surname>van Dalen</surname> <given-names>J</given-names></name> <name><surname>Gotthardt</surname> <given-names>M</given-names></name> <name><surname>Boellaard</surname> <given-names>R</given-names></name> <name><surname>Sera</surname> <given-names>T</given-names></name><etal/></person-group> <article-title>Multicentre quantitative (68)Ga PET/CT performance harmonisation.</article-title> <source><italic>EJNMMI Phys.</italic></source> (<year>2019</year>) <volume>6</volume>:<issue>19</issue>. <pub-id pub-id-type="doi">10.1186/s40658-019-0253-z</pub-id> <pub-id pub-id-type="pmid">31705215</pub-id></citation></ref>
<ref id="B23"><label>23.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Velikyan</surname> <given-names>I</given-names></name> <name><surname>Sundin</surname> <given-names>A</given-names></name> <name><surname>S&#x00F6;rensen</surname> <given-names>J</given-names></name> <name><surname>Lubberink</surname> <given-names>M</given-names></name> <name><surname>Sandstr&#x00F6;m</surname> <given-names>M</given-names></name> <name><surname>Garske-Rom&#x00E1;n</surname> <given-names>U</given-names></name><etal/></person-group> <article-title>Quantitative and qualitative intrapatient comparison of 68Ga-DOTATOC and 68Ga-DOTATATE: net uptake rate for accurate quantification.</article-title> <source><italic>J Nucl Med.</italic></source> (<year>2014</year>) <volume>55</volume>:<fpage>204</fpage>&#x2013;<lpage>10</lpage>. <pub-id pub-id-type="doi">10.2967/jnumed.113.126177</pub-id> <pub-id pub-id-type="pmid">24379222</pub-id></citation></ref>
<ref id="B24"><label>24.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kaemmerer</surname> <given-names>D</given-names></name> <name><surname>Peter</surname> <given-names>L</given-names></name> <name><surname>Lupp</surname> <given-names>A</given-names></name> <name><surname>Schulz</surname> <given-names>S</given-names></name> <name><surname>S&#x00E4;nger</surname> <given-names>J</given-names></name> <name><surname>Prasad</surname> <given-names>V</given-names></name><etal/></person-group> <article-title>Molecular imaging with <sup>68</sup>Ga-SSTR PET/CT and correlation to immunohistochemistry of somatostatin receptors in neuroendocrine tumours.</article-title> <source><italic>Eur J Nucl Med Mol Imaging.</italic></source> (<year>2011</year>) <volume>38</volume>:<fpage>1659</fpage>&#x2013;<lpage>68</lpage>. <pub-id pub-id-type="doi">10.1007/s00259-011-1846-5</pub-id> <pub-id pub-id-type="pmid">21626438</pub-id></citation></ref>
<ref id="B25"><label>25.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sher</surname> <given-names>A</given-names></name> <name><surname>Lacoeuille</surname> <given-names>F</given-names></name> <name><surname>Fosse</surname> <given-names>P</given-names></name> <name><surname>Vervueren</surname> <given-names>L</given-names></name> <name><surname>Cahouet-Vannier</surname> <given-names>A</given-names></name> <name><surname>Dabli</surname> <given-names>D</given-names></name><etal/></person-group> <article-title>For avid glucose tumors, the SUV peak is the most reliable parameter for [(18)F]FDG-PET/CT quantification, regardless of acquisition time.</article-title> <source><italic>EJNMMI Res.</italic></source> (<year>2016</year>) <volume>6</volume>:<issue>21</issue>. <pub-id pub-id-type="doi">10.1186/s13550-016-0177-8</pub-id> <pub-id pub-id-type="pmid">26944734</pub-id></citation></ref>
</ref-list>
</back>
</article>
