<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Med. Technol.</journal-id>
<journal-title>Frontiers in Medical Technology</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Med. Technol.</abbrev-journal-title>
<issn pub-type="epub">2673-3129</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fmedt.2022.881930</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Medical Technology</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Critical Study on the Tube-to-Chip Luer Slip Connectors</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes">
<name><surname>Etxeberria</surname> <given-names>Leire</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<xref ref-type="corresp" rid="c001"><sup>&#x0002A;</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/1654308/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Aguilera</surname> <given-names>Unai</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/1761858/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Garcia de Madinabeitia</surname> <given-names>Pablo</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/1692063/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Saez</surname> <given-names>Alberto</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Zaldua</surname> <given-names>Ane M.</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Vilas-Vilela</surname> <given-names>Jos&#x000E9; L.</given-names></name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<xref ref-type="aff" rid="aff4"><sup>4</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Fern&#x000E1;ndez</surname> <given-names>Luis</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Llobera</surname> <given-names>Andreu</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
</contrib>
</contrib-group>
<aff id="aff1"><sup>1</sup><institution>microLIQUID S.L</institution>, <addr-line>Arrasate-Mondrag&#x000F3;n</addr-line>, <country>Spain</country></aff>
<aff id="aff2"><sup>2</sup><institution>Leartiker S. Coop.</institution>, <addr-line>Markina-Xemein</addr-line>, <country>Spain</country></aff>
<aff id="aff3"><sup>3</sup><institution>Macromolecular Chemistry Research Group (LabQuiMac), Department of Physical Chemistry, Faculty of Science and Technology, University of the Basque Country (UPV/EHU)</institution>, <addr-line>Leioa</addr-line>, <country>Spain</country></aff>
<aff id="aff4"><sup>4</sup><institution>BC Materials, Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park</institution>, <addr-line>Leioa</addr-line>, <country>Spain</country></aff>
<author-notes>
<fn fn-type="edited-by"><p>Edited by: Nan Zhang, University College Dublin, Ireland</p></fn>
<fn fn-type="edited-by"><p>Reviewed by: Khashayar Khoshmanesh, RMIT University, Australia; Nan Xiang, Southeast University, China</p></fn>
<corresp id="c001">&#x0002A;Correspondence: Leire Etxeberria <email>letxeberria&#x00040;leartiker.com</email></corresp>
<fn fn-type="other" id="fn001"><p>This article was submitted to Medtech Data Analytics, a section of the journal Frontiers in Medical Technology</p></fn></author-notes>
<pub-date pub-type="epub">
<day>31</day>
<month>05</month>
<year>2022</year>
</pub-date>
<pub-date pub-type="collection">
<year>2022</year>
</pub-date>
<volume>4</volume>
<elocation-id>881930</elocation-id>
<history>
<date date-type="received">
<day>23</day>
<month>02</month>
<year>2022</year>
</date>
<date date-type="accepted">
<day>26</day>
<month>04</month>
<year>2022</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x000A9; 2022 Etxeberria, Aguilera, Garcia de Madinabeitia, Saez, Zaldua, Vilas-Vilela, Fern&#x000E1;ndez and Llobera.</copyright-statement>
<copyright-year>2022</copyright-year>
<copyright-holder>Etxeberria, Aguilera, Garcia de Madinabeitia, Saez, Zaldua, Vilas-Vilela, Fern&#x000E1;ndez and Llobera</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license> </permissions>
<abstract>
<p>Luer slip is one of the gold standards for chip-to-world interface in microfluidics. They have outstanding mechanical and operational robustness in a broad range of applications using water and solvent-based liquids. Still, their main drawbacks are related to their size: they have relatively large dead volumes and require a significant footprint to assure a leak-free performance. Such aspects make their integration in systems with high microchannel density challenging. To date, there has been no geometrical optimization of the Luer slips to provide a solution to the mentioned drawbacks. This work aims to provide the rules toward downscaling the Luer slips. To this effect, seven variations of the Luer slip male connectors and five variations of Luer slip female connectors have been designed and manufactured focusing on the reduction of the size of connectors and minimization of the dead volumes. In all cases, female connectors have been developed to pair with the corresponding male connector. Characterization has been performed with a tailor-made test bench in which the closure force between male and female connectors has been varied between 7.9 and 55 N. For each applied closure force, the test bench allows liquid pressures to be tested between 0.5 and 2.0 bar. Finally, the analysis of a useful life determines the number of cycles that the connectors can withstand before leakage.</p></abstract>
<kwd-group>
<kwd>LoC devices</kwd>
<kwd>microfluidic connectors</kwd>
<kwd>tube-to-chip connection</kwd>
<kwd>Luer slip connectors</kwd>
<kwd>useful life</kwd>
</kwd-group>
<contract-num rid="cn001">48-AF-W2-2018-00006</contract-num>
<contract-sponsor id="cn001">Eusko Jaurlaritza<named-content content-type="fundref-id">10.13039/501100003086</named-content></contract-sponsor>
<counts>
<fig-count count="7"/>
<table-count count="7"/>
<equation-count count="0"/>
<ref-count count="31"/>
<page-count count="8"/>
<word-count count="5023"/>
</counts>
</article-meta>
</front>
<body>
<sec sec-type="intro" id="s1">
<title>Introduction</title>
<p>Microfluidics and, more generally, Lab-on-a-chip (LoC) systems have broadly been used to develop analytical tools for pharmaceutical, life science, and diagnostics (<xref ref-type="bibr" rid="B1">1</xref>). To date, LoC has shown outstanding performance and integration level to develop complex laboratory procedures at the microscale while requiring minute amounts of sample varying in the &#x003BC;L-pL range (<xref ref-type="bibr" rid="B2">2</xref>&#x02013;<xref ref-type="bibr" rid="B6">6</xref>). Despite such extremely promising features, currently, microfluidics has only very seldomly reached commercial exploitation besides niche applications. The reason behind this weak economic impact can arguably be attributed to the chip-to-world interconnection (CWI) between the LoC and the peripherals (tubes, pumps, valves, etc.) (<xref ref-type="bibr" rid="B7">7</xref>&#x02013;<xref ref-type="bibr" rid="B10">10</xref>). Even though this need was already identified in 2003 by Lie et al. (<xref ref-type="bibr" rid="B11">11</xref>&#x02013;<xref ref-type="bibr" rid="B13">13</xref>), to date it is still an unsolved engineering need. Conceptually speaking, a robust CWI should (1) be biocompatible and chemically inert, (2) have zero or minimal dead volume, (3) be easy to plug, (4) be removable and reusable, (5) be reliable at operational pressures, (6) be made using simple and low-cost techniques, and (7) be fully compatible with commercial tubing and fittings (<xref ref-type="bibr" rid="B2">2</xref>).</p>
<p>Currently, one of the gold standards for CWI is the Luer slip connector due to easy handling and compatibility with medical and laboratory instruments, such as needles, syringes, and cannulas (<xref ref-type="bibr" rid="B3">3</xref>, <xref ref-type="bibr" rid="B14">14</xref>, <xref ref-type="bibr" rid="B15">15</xref>). The reason being is the ability to withstand fluidic pressures &#x0003E;2 bar without leakages, but equally important is to be automatable with a simple actuation movement and relative low force and being of multiple uses (<xref ref-type="bibr" rid="B2">2</xref>, <xref ref-type="bibr" rid="B16">16</xref>). Despite such outstanding properties, Luer connectors have also severe drawbacks, mainly related to their size, since they have relatively large dead volumes, and require a significant footprint to assure leak-free. This approach goes against dense packaging or multiplexing (<xref ref-type="bibr" rid="B17">17</xref>, <xref ref-type="bibr" rid="B18">18</xref>). Furthermore, as most prototyping techniques are not compatible for Luer manufacturing, researchers have sought for alternatives to Luer, such as a barb or direct connection without interfaces (<xref ref-type="bibr" rid="B19">19</xref>). The common industrial approach is then to develop highly specific connectors compatible only with their respective peripherals. Thus, a universal, reliable CWI is yet to be presented, hampering the overall applicability of LoC for large-scale applications.</p>
<p>Steps toward monolithic integration of Luer connectors with LoC have been done by taking advantage of the huge development of 3D printing. This technology offers flexibility, design freedom, and rapid prototype manufacturing providing good solutions for small fabrication volumes (<xref ref-type="bibr" rid="B20">20</xref>&#x02013;<xref ref-type="bibr" rid="B23">23</xref>). The introduction of this highly versatile technology has allowed the prototyping of arbitrary complex LoC with a broad range of materials. Specifically related to 3D printing of polymers, their outstanding properties in terms of lightweight, low cost, optical transparency, and in some cases chemical resistances are unmatchable by other materials (<xref ref-type="bibr" rid="B24">24</xref>&#x02013;<xref ref-type="bibr" rid="B26">26</xref>). Still, 3D printing is a serial process that lacks the required throughput to be considered as a mass-production technology. Even though there has been some progress related to multi-nozzle/parallel printing, it still can be considered as a technology only suitable for small batches, and other technologies, such as injection molding, are preferred since it is reported to be the cheapest and fastest approach for massive fabrication of LoC (<xref ref-type="bibr" rid="B16">16</xref>, <xref ref-type="bibr" rid="B27">27</xref>, <xref ref-type="bibr" rid="B28">28</xref>).</p>
<p>In this work, we aim to visualize this need from a different perspective. While keeping the full compatibility with injection molding, seven different Luer slip male connectors and five different Luer slip female connectors have been designed aiming toward the reduction of the aforementioned drawbacks while assuring their compatibility (whenever possible). To complete the study of the different approaches for tube-to-chip connection, the analysis of the useful life of the connector has been performed to define the number of cycles between 0 and 2 bar that the connectors can withstand before leakage.</p>
</sec>
<sec id="s2">
<title>Design and Working Principle</title>
<p>The proposed designs are based on the ISO 80369-7 (<xref ref-type="bibr" rid="B29">29</xref>) norm which defines the main parameters of the standard Luer connectors as shown in <xref ref-type="fig" rid="F1">Figure 1</xref>. The male connector is described in <xref ref-type="fig" rid="F1">Figure 1A</xref>, where &#x003B1; is the cone angle, &#x000D8;d is the external diameter in the extreme of the male cone at 0.750 mm, <italic>e</italic> is the length of the cone, &#x000D8;f is the internal diameter, &#x000D8;g is the external diameter in the extreme of the male cone at 7.500 mm, and <italic>r</italic> is the extreme exterior cone radius. The female connector is described in <xref ref-type="fig" rid="F1">Figure 1B</xref>, where &#x000D8;<sub>D</sub> is the external diameter in the extreme of the female cone at 0.750 mm, <italic>E</italic> is the depth of the cone, &#x000D8;<sub>G</sub> is the external diameter in the extreme of the female cone at 7.500 mm, &#x000D8;<sub>J</sub> is the external diameter of the female connector, and <italic>R</italic> is the radius on the entrance of the female cone.</p>
<fig id="F1" position="float">
<label>Figure 1</label>
<caption><p><bold>(A)</bold> Male and <bold>(B)</bold> female Luer connector drawings.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmedt-04-881930-g0001.tif"/>
</fig>
<p>The working principle in Luer Slip connectors is based on the fitting between the external face of the male connector and the internal face of the female connector. The holding is performed by friction on both surfaces. Therefore, the height and inner diameters that affect the friction area as well as the dead volume will be the most critical parameters for the correct functioning of the connectors.</p>
<p>Considering those parameters as critical, <xref ref-type="table" rid="T1">Table 1</xref> shows the new parameters proposed for both male and female designed connectors. Male 1 and Female 1 are the standard Luer connectors, which are considered the gold standards in this work. All dimensions have been downscaled to the half in Male 2 and three-fourths in Male 3. Minimization of the friction area between male and female connectors has been done by independently studying the different key regions of the Luer. Specifically, the connector height has been reduced to half and three-fourth in Male 4 and 5, while keeping the rest of the parameters unaltered. In Male 6 and Male 7, the inner diameter has been decreased to half and three-fourths, respectively, focusing on the reduction of dead volumes. In all cases, female connectors have been designed to pair with the corresponding male connectors. The compatibility between connectors is also summarized in <xref ref-type="table" rid="T1">Table 1</xref>.</p>
<table-wrap position="float" id="T1">
<label>Table 1</label>
<caption><p>Description of the designs for male and female connectors in mm.</p></caption>
<table frame="hsides" rules="groups">
<thead><tr>
<th/>
<th valign="top" align="center"><bold>&#x003B1;</bold></th>
<th valign="top" align="center"><bold>&#x000F8;d</bold></th>
<th valign="top" align="center"><bold>e</bold></th>
<th valign="top" align="center"><bold>&#x000F8;f</bold></th>
<th valign="top" align="center"><bold>&#x000F8;g</bold></th>
<th valign="top" align="center"><bold>r</bold></th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Male 1</td>
<td valign="top" align="center">3.440</td>
<td valign="top" align="center">4.021</td>
<td valign="top" align="center">8.400</td>
<td valign="top" align="center">2.100</td>
<td valign="top" align="center">4.426</td>
<td valign="top" align="center">0.250</td>
</tr>
<tr>
<td valign="top" align="left">Male 2</td>
<td/>
<td valign="top" align="center">2.011</td>
<td valign="top" align="center">4.200</td>
<td valign="top" align="center">1.050</td>
<td valign="top" align="center">2.213</td>
<td valign="top" align="center">0.125</td>
</tr>
<tr>
<td valign="top" align="left">Male 3</td>
<td/>
<td valign="top" align="center">3.016</td>
<td valign="top" align="center">6.300</td>
<td valign="top" align="center">1.575</td>
<td valign="top" align="center">3.320</td>
<td valign="top" align="center">0.188</td>
</tr>
<tr>
<td valign="top" align="left">Male 4</td>
<td/>
<td valign="top" align="center">4.021</td>
<td valign="top" align="center">4.200</td>
<td valign="top" align="center">2.100</td>
<td valign="top" align="center">4.426</td>
<td valign="top" align="center">0.250</td>
</tr>
<tr>
<td valign="top" align="left">Male 5</td>
<td/>
<td valign="top" align="center">4.021</td>
<td valign="top" align="center">6.300</td>
<td valign="top" align="center">2.100</td>
<td valign="top" align="center">4.426</td>
<td valign="top" align="center">0.250</td>
</tr>
<tr>
<td valign="top" align="left">Male 6</td>
<td/>
<td valign="top" align="center">4.021</td>
<td valign="top" align="center">8.400</td>
<td valign="top" align="center">1.050</td>
<td valign="top" align="center">4.426</td>
<td valign="top" align="center">0.250</td>
</tr>
<tr>
<td valign="top" align="left">Male 7</td>
<td/>
<td valign="top" align="center">4.021</td>
<td valign="top" align="center">8.400</td>
<td valign="top" align="center">1.575</td>
<td valign="top" align="center">4.426</td>
<td valign="top" align="center">0.250</td>
</tr> <tr style="border-top: thin solid #000000;">
<td/>
<td valign="top" align="center"><bold>&#x003B1;</bold> </td>
<td valign="top" align="center"><bold>&#x000F8;D</bold></td>
<td valign="top" align="center"><bold>E</bold></td>
<td valign="top" align="center"><bold>&#x000F8;G</bold></td>
<td valign="top" align="center"><bold>&#x000F8;J</bold></td>
<td valign="top" align="center"><bold>r</bold></td>
</tr> <tr style="border-top: thin solid #000000;">
<td valign="top" align="left">Female 1</td>
<td valign="top" align="center">3.440</td>
<td valign="top" align="center">4.248</td>
<td valign="top" align="center">8.400</td>
<td valign="top" align="center">3.843</td>
<td valign="top" align="center">6.356</td>
<td valign="top" align="center">0.250</td>
</tr>
<tr>
<td valign="top" align="left">Female 2</td>
<td/>
<td valign="top" align="center">2.124</td>
<td valign="top" align="center">4.200</td>
<td valign="top" align="center">1.922</td>
<td valign="top" align="center">3.178</td>
<td valign="top" align="center">0.125</td>
</tr>
<tr>
<td valign="top" align="left">Female 3</td>
<td/>
<td valign="top" align="center">3.186</td>
<td valign="top" align="center">6.300</td>
<td valign="top" align="center">2.882</td>
<td valign="top" align="center">4.767</td>
<td valign="top" align="center">0.188</td>
</tr>
<tr>
<td valign="top" align="left">Female 4</td>
<td/>
<td valign="top" align="center">4.248</td>
<td valign="top" align="center">4.200</td>
<td valign="top" align="center">3.843</td>
<td valign="top" align="center">6.356</td>
<td valign="top" align="center">0.250</td>
</tr>
<tr>
<td valign="top" align="left">Female 5</td>
<td/>
<td valign="top" align="center">4.248</td>
<td valign="top" align="center">6.300</td>
<td valign="top" align="center">3.483</td>
<td valign="top" align="center">6.356</td>
<td valign="top" align="center">0.250</td>
</tr>
 <tr style="border-top: thin solid #000000;">
<td valign="top" align="left" colspan="6"><bold>Compatibility</bold></td>
</tr>
<tr>
<td/>
<td/>
<td valign="top" align="left" colspan="2"><bold>Pair (Perfectly match)</bold></td>
<td valign="top" align="left" colspan="2"><bold>Compatible</bold></td>
</tr> <tr style="border-top: thin solid #000000;">
<td valign="top" align="left" colspan="2">Female 1</td>
<td valign="top" align="left" colspan="2">Male 1, 6 and 7</td>
<td valign="top" align="left" colspan="2">Male 4 and 5</td>
</tr>
<tr>
<td valign="top" align="left" colspan="2">Female 2</td>
<td valign="top" align="left" colspan="2">Male 2</td>
<td valign="top" align="left" colspan="2">-</td>
</tr>
<tr>
<td valign="top" align="left" colspan="2">Female 3</td>
<td valign="top" align="left" colspan="2">Male 3</td>
<td valign="top" align="left" colspan="2">-</td>
</tr>
<tr>
<td valign="top" align="left" colspan="2">Female 4</td>
<td valign="top" align="left" colspan="2">Male 4</td>
<td valign="top" align="left" colspan="2">Male 1, 5, 6 and 7</td>
</tr>
<tr>
<td valign="top" align="left" colspan="2">Female 5</td>
<td valign="top" align="left" colspan="2">Male 5</td>
<td valign="top" align="left" colspan="2">Male 1, 4, 6 and 7</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>Focusing toward standardization, a dedicated test bench has been built and is presented in <xref ref-type="fig" rid="F2">Figure 2</xref> and described in more detail in the <xref ref-type="supplementary-material" rid="SM1">Supplementary Material</xref>. The platform is composed of an aluminum base that holds for placing all the components in the correct position with fine alignment and distances. Thereby, the chip containing different male Luer slip connectors is placed on one side of the test bench. On the opposite side, a pneumatic actuator (CJP2B10-20D, SMC) can provide actuation forces larger than 55 N with response time (ON/OFF) in the millisecond range. In the resting position of the actuator, the connector is at a distance smaller than the maximum path of the actuator, so that when extended, both male and female connectors under study are interlocked. Switching off the pneumatic actuator assures returning to the initial position, allowing unloading of the measured pair.</p>
<fig id="F2" position="float">
<label>Figure 2</label>
<caption><p>Images of the test bench including the chip with male connectors and female connectors in red.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmedt-04-881930-g0002.tif"/>
</fig>
<p>The actuation force is dependent on the input pressure; therefore, it can be modulated using a pressure regulator as observed in the schematic setup of the test bench, in <xref ref-type="fig" rid="F3">Figure 3A</xref>. The obtained forces from applied pressure values provided by the datasheet are summarized in <xref ref-type="table" rid="T2">Table 2</xref>.</p>
<fig id="F3" position="float">
<label>Figure 3</label>
<caption><p>Experimental setup. <bold>(A)</bold> Schematic drawing of the test bench, <bold>(B)</bold> Image of the setup.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmedt-04-881930-g0003.tif"/>
</fig>
<table-wrap position="float" id="T2">
<label>Table 2</label>
<caption><p>Actuation force values.</p></caption>
<table frame="hsides" rules="groups">
<thead><tr>
<th valign="top" align="left"><bold>Pressure [bar]</bold></th>
<th valign="top" align="center"><bold>Force [<italic>N</italic>]</bold></th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">1</td>
<td valign="top" align="center">7.9 &#x000B1; 0.5</td>
</tr>
<tr>
<td valign="top" align="left">2</td>
<td valign="top" align="center">15.8 &#x000B1; 0.4</td>
</tr>
<tr>
<td valign="top" align="left">3</td>
<td valign="top" align="center">23.6 &#x000B1; 0.4</td>
</tr>
<tr>
<td valign="top" align="left">4</td>
<td valign="top" align="center">31.5 &#x000B1; 0.4</td>
</tr>
<tr>
<td valign="top" align="left">5</td>
<td valign="top" align="center">39.3 &#x000B1; 0.4</td>
</tr>
<tr>
<td valign="top" align="left">6</td>
<td valign="top" align="center">47.2 &#x000B1; 0.4</td>
</tr>
<tr>
<td valign="top" align="left">7</td>
<td valign="top" align="center">55.0 &#x000B1; 0.4</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>When the female connector reaches the male connector, the perfusion of the liquid starts. The fluid is driven with a required fluidic pressure from the reservoir using the pressure pump Fluigent MFCS&#x02122;-EZ. The tubing led the fluid to the female connector and once it matches the male connector, the fluid comes out through the outlet and is stored in a reservoir. The circuit has been connected to the connector using a commercial PEEK Threaded fitting for tube connections. <xref ref-type="fig" rid="F3">Figure 3B</xref> shows the image of the complete experimental setup (see <xref ref-type="supplementary-material" rid="SM1">Supplementary Information</xref> for details).</p>
</sec>
<sec sec-type="materials and methods" id="s3">
<title>Materials and Methods</title>
<sec>
<title>Materials</title>
<p>Male and Female connectors have been machined in different materials as the required properties vary. Male connectors are envisaged to be part of the LoC, and thus being single-use in most cases. Then, they have been machined in Ertalyte PET due to the dimensional stability, excellent wear resistance, and low coefficient of friction that offers. These properties make this material extremely suitable for the machining of high-precision parts (<xref ref-type="bibr" rid="B30">30</xref>). In addition, the designs can easily be transferred to injection molding technology. <xref ref-type="fig" rid="F4">Figure 4</xref> shows the CAD image of the chip containing male connectors.</p>
<fig id="F4" position="float">
<label>Figure 4</label>
<caption><p>CAD image of the chip containing male connectors.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmedt-04-881930-g0004.tif"/>
</fig>
<p>On the other hand, female connectors have been machined in Ketron PEEK material. The resistance and biocompatibility of PEEK allow longer use of female connectors including the use of solvents and even biological samples (<xref ref-type="bibr" rid="B31">31</xref>).</p>
</sec>
<sec>
<title>Methods</title>
<sec>
<title>Machining of Connectors</title>
<p>The equipment used for the machining of the connectors is KONDIA B-1000 Machining center. The requirements for machining are summarized in <xref ref-type="table" rid="T3">Table 3</xref> for male connectors and in <xref ref-type="table" rid="T4">Table 4</xref> for female connectors. The defined tolerances were 0.05 mm in XY and 0.1 mm in Z. The machining of male connectors was performed in three steps. In the first step, the rotation speed of the spindle was 5,000 rpm with a feed rate of 200 mm/rev, the plunge depth (Ap) of 2 mm, and pass width (Ae) of 0.375 mm. In the second step, the rotation speed of 6,500 rpm and a feed rate of 950 mm/rev have been used for bulk machining. Here, the conditions of Ap and Ae were 8 and 0.15 mm, respectively. In the last step, a finishing machining was executed with a rotation speed of 7,000 rpm, feed rate of 1,000 mm/rev, and with Ap and Ae of 2 and 0.12 mm, respectively. For female connectors, the rotation speed of the spindle for the external machining process was 1,200 rpm with a feed rate of 0.15 mm/rev. In the case of the internal machining process, the rotation speed was 900 m/min with a feed rate of 0.25 mm/rev. In both cases, Ap and Ae were 500 &#x003BC;m and 1.5 mm, respectively.</p>
<table-wrap position="float" id="T3">
<label>Table 3</label>
<caption><p>Machining requirements for Male connectors in Ertalyte.</p></caption>
<table frame="hsides" rules="groups">
<thead><tr>
<th valign="top" align="left"><bold>Male connectors</bold></th>
<th valign="top" align="center"><bold>Height [mm]</bold></th>
<th valign="top" align="center"><bold>External diameter (up) [mm]</bold></th>
<th valign="top" align="center"><bold>External diameter (bottom) [mm]</bold></th>
<th valign="top" align="center"><bold>Internal diameter [mm]</bold></th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Male 1</td>
<td valign="top" align="center">8.4 &#x000B1; 0.1</td>
<td valign="top" align="center">4.12 &#x000B1; 0.05</td>
<td valign="top" align="center">4.48 &#x000B1; 0.05</td>
<td valign="top" align="center">2.10 &#x000B1; 0.05</td>
</tr>
<tr>
<td valign="top" align="left">Male 2</td>
<td valign="top" align="center">4.2 &#x000B1; 0.1</td>
<td valign="top" align="center">2.03 &#x000B1; 0.05</td>
<td valign="top" align="center">2.22 &#x000B1; 0.05</td>
<td valign="top" align="center">1.05 &#x000B1; 0.05</td>
</tr>
<tr>
<td valign="top" align="left">Male 3</td>
<td valign="top" align="center">6.3 &#x000B1; 0.1</td>
<td valign="top" align="center">3.08 &#x000B1; 0.05</td>
<td valign="top" align="center">3.35 &#x000B1; 0.05</td>
<td valign="top" align="center">1.57 &#x000B1; 0.05</td>
</tr>
<tr>
<td valign="top" align="left">Male 4</td>
<td valign="top" align="center">4.2 &#x000B1; 0.1</td>
<td valign="top" align="center">4.12 &#x000B1; 0.05</td>
<td valign="top" align="center">4.23 &#x000B1; 0.05</td>
<td valign="top" align="center">2.10 &#x000B1; 0.05</td>
</tr>
<tr>
<td valign="top" align="left">Male 5</td>
<td valign="top" align="center">6.3 &#x000B1; 0.1</td>
<td valign="top" align="center">4.12 &#x000B1; 0.05</td>
<td valign="top" align="center">4.35 &#x000B1; 0.05</td>
<td valign="top" align="center">2.10 &#x000B1; 0.05</td>
</tr>
<tr>
<td valign="top" align="left">Male 6</td>
<td valign="top" align="center">8.4 &#x000B1; 0.1</td>
<td valign="top" align="center">4.12 &#x000B1; 0.05</td>
<td valign="top" align="center">4.48 &#x000B1; 0.05</td>
<td valign="top" align="center">1.05 &#x000B1; 0.05</td>
</tr>
<tr>
<td valign="top" align="left">Male 7</td>
<td valign="top" align="center">8.4 &#x000B1; 0.1</td>
<td valign="top" align="center">4.12 &#x000B1; 0.05</td>
<td valign="top" align="center">4.48 &#x000B1; 0.05</td>
<td valign="top" align="center">1.58 &#x000B1; 0.05</td>
</tr>
</tbody>
</table>
</table-wrap>
<table-wrap position="float" id="T4">
<label>Table 4</label>
<caption><p>Machining requirements for Female connectors in Ketron PEEK.</p></caption>
<table frame="hsides" rules="groups">
<thead><tr>
<th valign="top" align="left"><bold>Female connectors</bold></th>
<th valign="top" align="left"><bold>Height in the connection area [mm]</bold></th>
<th valign="top" align="left"><bold>Internal diameter connection area (Up) [mm]</bold></th>
<th valign="top" align="left"><bold>Internal diameter connection area (Bottom) [mm]</bold></th>
<th valign="top" align="center"><bold>External diameter [mm]</bold></th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Female 1</td>
<td valign="top" align="left">8.4 &#x000B1; 0.1</td>
<td valign="top" align="left">3.79 &#x000B1; 0.05</td>
<td valign="top" align="left">4.28 &#x000B1; 0.05</td>
<td valign="top" align="center">11.50 &#x000B1; 0.05</td>
</tr>
<tr>
<td valign="top" align="left">Female 2</td>
<td valign="top" align="left">4.2 &#x000B1; 0.1</td>
<td valign="top" align="left">1.92 &#x000B1; 0.05</td>
<td valign="top" align="left">2.17 &#x000B1; 0.05</td>
<td valign="top" align="center">11.50 &#x000B1; 0.05</td>
</tr>
<tr>
<td valign="top" align="left">Female 3</td>
<td valign="top" align="left">6.3 &#x000B1; 0.1</td>
<td valign="top" align="left">2.40 &#x000B1; 0.05</td>
<td valign="top" align="left">3.59 &#x000B1; 0.05</td>
<td valign="top" align="center">11.50 &#x000B1; 0.05</td>
</tr>
<tr>
<td valign="top" align="left">Female 4</td>
<td valign="top" align="left">4.2 &#x000B1; 0.1</td>
<td valign="top" align="left">4.04 &#x000B1; 0.05</td>
<td valign="top" align="left">4.28 &#x000B1; 0.05</td>
<td valign="top" align="center">11.50 &#x000B1; 0.05</td>
</tr>
<tr>
<td valign="top" align="left">Female 5</td>
<td valign="top" align="left">6.3 &#x000B1; 0.1</td>
<td valign="top" align="left">3.91 &#x000B1; 0.05</td>
<td valign="top" align="left">4.28 &#x000B1; 0.05</td>
<td valign="top" align="center">11.50 &#x000B1; 0.05</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
<sec>
<title>Characterization of Machined Parts</title>
<p>The dimensional control of the connectors was performed using a digital caliper for external diameter and height measurements and Nikon Eclipse 80i optical microscopy for internal diameter measurements. Moreover, 3D images of the connectors have been obtained using an optical profilometer ZYGO ZeGage Pro (Obj: 10X).</p>
<p>The fluidic tests have been performed using the setup described in <xref ref-type="fig" rid="F3">Figure 3</xref>. Male-female closure has been checked between 7.9 and 55 N. For each applied closure force, the test bench allows liquid pressures to be tested between 0.5 and 2.0 bar. The upper-pressure limit is due to the pumping system (Fluigent MFCS&#x02122;-EZ) and not on the selected pneumatic actuator.</p>
<p>Arguably, a fluidic pressure of 2.0 bar covers most of the microfluidic applications. Therefore, this fluidic pressure value has been defined as a final target in this work. The minimum required closing force at which the connector can withstand 2.0 bar of fluidic pressure without leakage has been analyzed. For each defined closing force, the number of cycles that the connectors last before leakage has been studied performing a useful life analysis. Using the test bench, the connectors have been actuated up to 100 times applying 2.0 bar fluidic pressure at defined closure force.</p>
</sec>
</sec>
</sec>
<sec id="s4">
<title>Results and Discussion</title>
<sec>
<title>Dimensional Control of Machined Parts</title>
<p>The 3D image of the upper part of the male connector obtained using the optical profilometer is shown in <xref ref-type="fig" rid="F5">Figure 5</xref>. Despite the visible machining marks on the outer wall of the connector, the picture shows a reliable image of the connector.</p>
<fig id="F5" position="float">
<label>Figure 5</label>
<caption><p>Optical profilometer image of a male connector.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmedt-04-881930-g0005.tif"/>
</fig>
<p><xref ref-type="fig" rid="F6">Figure 6</xref> shows images obtained with the Nikon Eclipse 80i optical microscopy for dimensional control of machined parts. In this case, although the machining marks are more visible on the surface of the female connector, the male connector shows machining traces and thus, rougher finishing.</p>
<fig id="F6" position="float">
<label>Figure 6</label>
<caption><p>Images obtained with Nikon Eclipse 80i optical microscopy. <bold>(A)</bold> Male connector, <bold>(B)</bold> Female connector.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmedt-04-881930-g0006.tif"/>
</fig>
<p><xref ref-type="table" rid="T5">Tables 5</xref>, <xref ref-type="table" rid="T6">6</xref> present the measured dimensions of male and female connectors, respectively. In most of the cases, machined parts are according to the design specifications. The highest deviation can be observed in the internal diameter in female connectors. These deviations may be due to the measurement method and do not affect the overall characterization of the connectors.</p>
<table-wrap position="float" id="T5">
<label>Table 5</label>
<caption><p>Measured dimensions of Male connectors.</p></caption>
<table frame="hsides" rules="groups">
<thead><tr>
<th valign="top" align="left"><bold>Male connectors</bold></th>
<th valign="top" align="center" colspan="2" style="border-bottom: thin solid #000000;"><bold>Height [mm]</bold></th>
<th valign="top" align="center" colspan="2" style="border-bottom: thin solid #000000;"><bold>External diameter (up) [mm]</bold></th>
<th valign="top" align="center" colspan="2" style="border-bottom: thin solid #000000;"><bold>External diameter (bottom) [mm]</bold></th>
<th valign="top" align="center" colspan="2" style="border-bottom: thin solid #000000;"><bold>Internal diameter [mm]</bold></th>
</tr>
<tr>
<th/>
<th valign="top" align="left"><bold>Meas</bold>.</th>
<th valign="top" align="left"><bold>Dev</bold>.</th>
<th valign="top" align="left"><bold>Meas</bold>.</th>
<th valign="top" align="left"><bold>Dev</bold>.</th>
<th valign="top" align="left"><bold>Meas</bold>.</th>
<th valign="top" align="left"><bold>Dev</bold>.</th>
<th valign="top" align="left"><bold>Meas</bold>.</th>
<th valign="top" align="left"><bold>Dev</bold>.</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Male 1</td>
<td valign="top" align="left">8.50</td>
<td valign="top" align="left">&#x0002B;0.1</td>
<td valign="top" align="left">4.10</td>
<td valign="top" align="left">&#x02212;0.02</td>
<td valign="top" align="left">4.48</td>
<td valign="top" align="left">&#x0002B;0.01</td>
<td valign="top" align="left">2.10</td>
<td valign="top" align="left">&#x0002B;0.01</td>
</tr>
<tr>
<td valign="top" align="left">Male 2</td>
<td valign="top" align="left">4.17</td>
<td valign="top" align="left">&#x02212;0.03</td>
<td valign="top" align="left">2.10</td>
<td valign="top" align="left">&#x0002B;0.07</td>
<td valign="top" align="left">2.24</td>
<td valign="top" align="left">&#x0002B;0.02</td>
<td valign="top" align="left">1.1</td>
<td valign="top" align="left">&#x0002B;0.05</td>
</tr>
<tr>
<td valign="top" align="left">Male 3</td>
<td valign="top" align="left">6.24</td>
<td valign="top" align="left">&#x02212;0.06</td>
<td valign="top" align="left">3.12</td>
<td valign="top" align="left">&#x0002B;0.04</td>
<td valign="top" align="left">3.38</td>
<td valign="top" align="left">&#x0002B;0.03</td>
<td valign="top" align="left">1.73</td>
<td valign="top" align="left">&#x0002B;0.16</td>
</tr>
<tr>
<td valign="top" align="left">Male 4</td>
<td valign="top" align="left">4.19</td>
<td valign="top" align="left">&#x02212;0.01</td>
<td valign="top" align="left">4.12</td>
<td valign="top" align="left">&#x0002B;0.01</td>
<td valign="top" align="left">4.27</td>
<td valign="top" align="left">&#x0002B;0.05</td>
<td valign="top" align="left">2.15</td>
<td valign="top" align="left">&#x0002B;0.05</td>
</tr>
<tr>
<td valign="top" align="left">Male 5</td>
<td valign="top" align="left">6.26</td>
<td valign="top" align="left">&#x02212;0.04</td>
<td valign="top" align="left">4.12</td>
<td valign="top" align="left">&#x0002B;0.01</td>
<td valign="top" align="left">4.38</td>
<td valign="top" align="left">&#x0002B;0.03</td>
<td valign="top" align="left">2.08</td>
<td valign="top" align="left">&#x02212;0.02</td>
</tr>
<tr>
<td valign="top" align="left">Male 6</td>
<td valign="top" align="left">8.47</td>
<td valign="top" align="left">&#x0002B;0.07</td>
<td valign="top" align="left">4.10</td>
<td valign="top" align="left">&#x02212;0.02</td>
<td valign="top" align="left">4.51</td>
<td valign="top" align="left">&#x0002B;0.03</td>
<td valign="top" align="left">1.01</td>
<td valign="top" align="left">&#x02212;0.04</td>
</tr>
<tr>
<td valign="top" align="left">Male 7</td>
<td valign="top" align="left">8.42</td>
<td valign="top" align="left">&#x0002B;0.02</td>
<td valign="top" align="left">4.09</td>
<td valign="top" align="left">&#x02212;0.03</td>
<td valign="top" align="left">4.51</td>
<td valign="top" align="left">&#x0002B;0.03</td>
<td valign="top" align="left">1.63</td>
<td valign="top" align="left">&#x0002B;0.05</td>
</tr>
</tbody>
</table>
</table-wrap>
<table-wrap position="float" id="T6">
<label>Table 6</label>
<caption><p>Measured dimensions of Female connectors.</p></caption>
<table frame="hsides" rules="groups">
<thead><tr>
<th valign="top" align="left"><bold>Female connectors</bold></th>
<th valign="top" align="center" colspan="2" style="border-bottom: thin solid #000000;"><bold>Height in the connection area [mm]</bold></th>
<th valign="top" align="center" colspan="2" style="border-bottom: thin solid #000000;"><bold>Internal diameter connection area (Up) [mm]</bold></th>
<th valign="top" align="center" colspan="2" style="border-bottom: thin solid #000000;"><bold>Internal diameter connection area (Bottom) [mm]</bold></th>
<th valign="top" align="center" colspan="2" style="border-bottom: thin solid #000000;"><bold>External diameter [mm]</bold></th>
</tr>
<tr>
<th/>
<th valign="top" align="left"><bold>Meas</bold>.</th>
<th valign="top" align="left"><bold>Dev</bold>.</th>
<th valign="top" align="left"><bold>Meas</bold>.</th>
<th valign="top" align="left"><bold>Dev</bold>.</th>
<th valign="top" align="left"><bold>Meas</bold>.</th>
<th valign="top" align="left"><bold>Dev</bold>.</th>
<th valign="top" align="left"><bold>Meas</bold>.</th>
<th valign="top" align="left"><bold>Dev</bold>.</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Female 1</td>
<td valign="top" align="left">8.39</td>
<td valign="top" align="left">&#x02212;0.01</td>
<td valign="top" align="left">3.76</td>
<td valign="top" align="left">&#x02212;0.03</td>
<td valign="top" align="left">4.19</td>
<td valign="top" align="left">&#x02212;0.09</td>
<td valign="top" align="left">11.54</td>
<td valign="top" align="left">&#x0002B;0.04</td>
</tr>
<tr>
<td valign="top" align="left">Female 2</td>
<td valign="top" align="left">&#x02013;</td>
<td valign="top" align="left">&#x02013;</td>
<td valign="top" align="left">&#x02013;</td>
<td valign="top" align="left">&#x02013;</td>
<td valign="top" align="left">2.17</td>
<td valign="top" align="left">&#x0002B;0.01</td>
<td valign="top" align="left">11.46</td>
<td valign="top" align="left">&#x02212;0.04</td>
</tr>
<tr>
<td valign="top" align="left">Female 3</td>
<td valign="top" align="left">6.31</td>
<td valign="top" align="left">&#x0002B;0.01</td>
<td valign="top" align="left">&#x02013;</td>
<td valign="top" align="left">&#x02013;</td>
<td valign="top" align="left">3.53</td>
<td valign="top" align="left">&#x02212;0.06</td>
<td valign="top" align="left">11.5</td>
<td valign="top" align="left">&#x0002B;0.01</td>
</tr>
<tr>
<td valign="top" align="left">Female 4</td>
<td valign="top" align="left">4.23</td>
<td valign="top" align="left">&#x0002B;0.03</td>
<td valign="top" align="left">4.07</td>
<td valign="top" align="left">&#x0002B;0.03</td>
<td valign="top" align="left">4.24</td>
<td valign="top" align="left">&#x02212;0.04</td>
<td valign="top" align="left">11.49</td>
<td valign="top" align="left">&#x02212;0.01</td>
</tr>
<tr>
<td valign="top" align="left">Female 5</td>
<td valign="top" align="left">6.31</td>
<td valign="top" align="left">&#x0002B;0.01</td>
<td valign="top" align="left">&#x02013;</td>
<td valign="top" align="left">&#x02013;</td>
<td valign="top" align="left">4.22</td>
<td valign="top" align="left">&#x02212;0.06</td>
<td valign="top" align="left">11.47</td>
<td valign="top" align="left">&#x02212;0.03</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>In conclusion, although machined parts show traces and marks typical of the process, the connectors are machined as specified and thus, have been considered as valid for this work.</p>
</sec>
<sec>
<title>Fluidic Tests</title>
<p>Different combinations of male-female Luers have been tested&#x02014;if compatible&#x02014;and the results have been summarized in <xref ref-type="table" rid="T7">Table 7</xref>. Thereby, the minimum required closure force to achieve the goal is presented.</p>
<table-wrap position="float" id="T7">
<label>Table 7</label>
<caption><p>Results for minimum closure force required to hold on 2.0 bar fluidic pressure for each possible connector combination.</p></caption>
<table frame="hsides" rules="groups">
<thead><tr>
<th valign="top" align="left"><bold>Connector type</bold></th>
<th valign="top" align="left"><bold>Female 1</bold></th>
<th valign="top" align="left"><bold>Female 2</bold></th>
<th valign="top" align="left"><bold>Female 3</bold></th>
<th valign="top" align="left"><bold>Female 4</bold></th>
<th valign="top" align="left"><bold>Female 5</bold></th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Male 1</td>
<td valign="top" align="left">47.2 &#x000B1; 0.4N</td>
<td valign="top" align="left">Not compatible</td>
<td valign="top" align="left">Not compatible</td>
<td valign="top" align="left">39.3 &#x000B1; 0.4N</td>
<td valign="top" align="left">39.3 &#x000B1; 0.4 N</td>
</tr>
<tr>
<td valign="top" align="left">Male 2</td>
<td valign="top" align="left">Not compatible</td>
<td valign="top" align="left">31.5 &#x000B1; 0.4 N</td>
<td valign="top" align="left">Not compatible</td>
<td valign="top" align="left">Not compatible</td>
<td valign="top" align="left">Not compatible</td>
</tr>
<tr>
<td valign="top" align="left">Male 3</td>
<td valign="top" align="left">Not compatible</td>
<td valign="top" align="left">Not compatible</td>
<td valign="top" align="left">15.8 &#x000B1; 0.4N</td>
<td valign="top" align="left">Not compatible</td>
<td valign="top" align="left">Not compatible</td>
</tr>
<tr>
<td valign="top" align="left">Male 4</td>
<td valign="top" align="left">23.6 &#x000B1; 0.4 N</td>
<td valign="top" align="left">Not compatible</td>
<td valign="top" align="left">Not compatible</td>
<td valign="top" align="left">23.6 &#x000B1; 0.4 N</td>
<td valign="top" align="left">47.2 &#x000B1; 0.4N</td>
</tr>
<tr>
<td valign="top" align="left">Male 5</td>
<td valign="top" align="left">47.2 &#x000B1; 0.4 N</td>
<td valign="top" align="left">Not compatible</td>
<td valign="top" align="left">Not compatible</td>
<td valign="top" align="left">2.0 bar fluidic pressure not reached</td>
<td valign="top" align="left">55.0 &#x000B1; 0.4 N</td>
</tr>
<tr>
<td valign="top" align="left">Male 6</td>
<td valign="top" align="left">55.0 &#x000B1; 0.4N</td>
<td valign="top" align="left">Not compatible</td>
<td valign="top" align="left">Not compatible</td>
<td valign="top" align="left">55.0 &#x000B1; 0.4 N</td>
<td valign="top" align="left">55.0 &#x000B1; 0.4N</td>
</tr>
<tr>
<td valign="top" align="left">Male 7</td>
<td valign="top" align="left">39.3 &#x000B1; 0.4N</td>
<td valign="top" align="left">Not compatible</td>
<td valign="top" align="left">Not compatible</td>
<td valign="top" align="left">2.0 bar fluidic pressure not reached</td>
<td valign="top" align="left">47.2 &#x000B1; 0.4 N</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>The results show that a reduction of height in the connectors (M4) is more suited at low connection force (above 25 N in its pair connector) due to the friction reduction between male and female parts. Contrarywise, reduction of internal diameter (M6, M7) causes an increase in the liquid velocity, making this more prone to leakage. From this data, it can be concluded that the best compromise is with M2 and M3, where an overall downscaling of all parameters has been done as compared to the gold standard and still retains its performance. This downscaling allows us to address the aforementioned discussion regarding the footprint and dead volumes, since it will allow a denser interconnection in advanced LoC.</p>
<p>In the theoretical case, leakage will only depend on the contact pressure between the connectors. Nevertheless, the length of the contact area and the surface finishing also affect the connector quality increasing the required closure force. The applied forces and the deformations in the material can also affect the quality of the connection. In this case, values of deformation and tensile stress at yield of both materials taken from the datasheets are much higher than expected experimental values, suggesting that the material will always work in the elastic region.</p>
<p>Regarding the useful life of the connector, the analysis of the number of cycles before leakage with 2.0 bar of fluidic pressure plotted in <xref ref-type="fig" rid="F7">Figure 7</xref> shows that although the friction reduction between male and female (M4) needs a lower connection force, the number of cycles before leakage reduces considerably. The reduction of the internal diameter (M6, M7) and the downscaling (M2, M3) of the connectors do not affect the useful life of the connector.</p>
<fig id="F7" position="float">
<label>Figure 7</label>
<caption><p>Number of cycles before leakage at 2 bar fluidic pressure for each possible connector combination.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fmedt-04-881930-g0007.tif"/>
</fig>
<p>It is therefore concluded that downscaled connectors (M2, M3) are the most reliable ones showing the best compromise between the dead volumes, due to their size and performance, requiring low closing forces, and lasting at least 100 cycles. Fluidic tests have been performed with 2 bar of fluidic pressure limited by the working range of the pressure pump. Although the defined maximum fluidic pressure is in the range of interest for microfluidic applications, the good behavior of the connectors in the tests suggests possible satisfactory performance also at higher fluidic pressure values.</p>
</sec>
</sec>
<sec sec-type="conclusions" id="s5">
<title>Conclusions</title>
<p>In this work, seven variations of the Luer slip male connectors and five variations of Luer slip female connectors have been designed, manufactured, and characterized to elucidate the strategies toward decreasing the footprint while retaining its performance. The main goal is the path to upscaling a reliable CWI in the LoC application.</p>
<p>Using a specifically designed and developed test bench, a minimum closure force required to hold on 2.0 bar fluidic pressure has been analyzed in which the downscaled connectors show the best compromise between the dead volume and closing force demanding 31.5 &#x000B1; 0.4 N (M2) and 15.8 &#x000B1; 0.4 N (M3). For the required closing force, a useful life analysis of the connectors has been performed by applying 100 closing cycles for each possible connector combination. Most of the compatible connectors withstand 100 cycles before leakage, except for the cases in which the friction area has been reduced (M4).</p>
<p>The study shows that the proportional downscaling of all dimensions in the standard Luer Slip connector allows the reduction of dead volumes without compromising the functionality of the connector. Furthermore, size reduction permits dense packaging or multiplexing in LoC devices and massive manufacturing of them using injection molding.</p>
</sec>
<sec sec-type="data-availability" id="s6">
<title>Data Availability Statement</title>
<p>The original contributions presented in the study are included in the article/<xref ref-type="sec" rid="s10">Supplementary Material</xref>, further inquiries can be directed to the corresponding authors.</p>
</sec>
<sec id="s7">
<title>Author Contributions</title>
<p>LE, UA, PG, and AS contributed to the design and manufacturing of the connectors. UA prepared the CAD designs and the organization of the setup. LE performed the experiments and wrote the first draft of the manuscript. JV-V contributed to assessment during revisions. AZ, LF, and JV-V contributed with the founding and resources. AL contributed with the supervision and project administration. All authors contributed to manuscript revision, read, and approved the submitted version.</p>
</sec>
<sec sec-type="funding-information" id="s8">
<title>Funding</title>
<p>The authors are grateful for the financial support from the Basque Country Government within the frame of the project BIKAINTEK 2018 (48-AF-W2-2018-00006).</p>
</sec>
<sec sec-type="COI-statement" id="conf1">
<title>Conflict of Interest</title>
<p>LE, UA, PG, AS, LF, and AL were employed by microLIQUID S.L. LE and AZ were employed by Leartiker S. Coop. JV-V were employed by UPV/EHU and BC Materials. LE is a student of UPV/EHU.</p>
</sec>
<sec sec-type="disclaimer" id="s9">
<title>Publisher&#x00027;s Note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec> </body>
<back>
<sec sec-type="supplementary-material" id="s10">
<title>Supplementary Material</title>
<p>The Supplementary Material for this article can be found online at: <ext-link ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/fmedt.2022.881930/full#supplementary-material">https://www.frontiersin.org/articles/10.3389/fmedt.2022.881930/full#supplementary-material</ext-link></p>
<supplementary-material xlink:href="Data_Sheet_1.docx" id="SM1" mimetype="application/vnd.openxmlformats-officedocument.wordprocessingml.document" xmlns:xlink="http://www.w3.org/1999/xlink"/>
</sec>
<ref-list>
<title>References</title>
<ref id="B1">
<label>1.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fernandez-Cuesta</surname> <given-names>I</given-names></name> <name><surname>Llobera</surname> <given-names>A</given-names></name> <name><surname>Ramos-Pay&#x000E1;n</surname> <given-names>M</given-names></name></person-group>. <article-title>Optofluidic systems enabling detection in real samples: a review</article-title>. <source>Anal Chim Acta.</source> (<year>2022</year>) <volume>1192</volume>:<fpage>339307</fpage>. <pub-id pub-id-type="doi">10.1016/j.aca.2021.339307</pub-id><pub-id pub-id-type="pmid">35057965</pub-id></citation></ref>
<ref id="B2">
<label>2.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Temiz</surname> <given-names>Y</given-names></name> <name><surname>Lovchik</surname> <given-names>RD</given-names></name> <name><surname>Kaigala</surname> <given-names>GV</given-names></name> <name><surname>Delamarche</surname> <given-names>E</given-names></name></person-group>. <article-title>Lab-on-a-chip devices: How to close and plug the lab?</article-title> <source>Microelectronic Eng.</source> (<year>2015</year>) <volume>132</volume>:<fpage>156</fpage>&#x02013;<lpage>75</lpage>. <pub-id pub-id-type="doi">10.1016/j.mee.2014.10.013</pub-id></citation>
</ref>
<ref id="B3">
<label>3.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Livak-Dahl</surname> <given-names>E</given-names></name> <name><surname>Sinn</surname> <given-names>I</given-names></name> <name><surname>Burns</surname> <given-names>M</given-names></name></person-group>. <article-title>Microfluidic chemical analysis systems</article-title>. <source>Annu Rev Chem Biomol Eng.</source> (<year>2011</year>) <volume>2</volume>:<fpage>325</fpage>&#x02013;<lpage>53</lpage>. <pub-id pub-id-type="doi">10.1146/annurev-chembioeng-061010-114215</pub-id><pub-id pub-id-type="pmid">22432622</pub-id></citation></ref>
<ref id="B4">
<label>4.</label>
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Christoffersson</surname> <given-names>J</given-names></name> <name><surname>Mandenius</surname> <given-names>C-F</given-names></name></person-group>. <article-title>Using a Microfluidic Device for Culture and Drug Toxicity Testing of 3D Cells</article-title>. In: Mandenius C-F, Ross JA, editors. <source>Cell-Based Assays Using iPSCs for Drug Development and Testing</source>. <publisher-loc>New York, NY</publisher-loc>: <publisher-name>Springer</publisher-name> (<year>2019</year>). p <fpage>235</fpage>&#x02013;<lpage>241</lpage>. <pub-id pub-id-type="doi">10.1007/978-1-4939-9477-9_22</pub-id><pub-id pub-id-type="pmid">31124121</pub-id></citation></ref>
<ref id="B5">
<label>5.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Holloway</surname> <given-names>PM</given-names></name> <name><surname>Willaime-Morawek</surname> <given-names>S</given-names></name> <name><surname>Siow</surname> <given-names>R</given-names></name> <name><surname>Barber</surname> <given-names>M</given-names></name> <name><surname>Owens</surname> <given-names>RM</given-names></name> <name><surname>Sharma</surname> <given-names>AD</given-names></name> <etal/></person-group>. <article-title>Advances in microfluidic <italic>in vitro</italic> systems for neurological disease modeling</article-title>. <source>J Neurosci Res.</source> (<year>2021</year>) <volume>99</volume>:<fpage>1276</fpage>&#x02013;<lpage>307</lpage>. <pub-id pub-id-type="doi">10.1002/jnr.24794</pub-id><pub-id pub-id-type="pmid">33583054</pub-id></citation></ref>
<ref id="B6">
<label>6.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Becker</surname> <given-names>H</given-names></name></person-group>. <article-title>One size fits all?</article-title> <source>Lab Chip.</source> (<year>2010</year>) <volume>10</volume>:<fpage>1894</fpage>. <pub-id pub-id-type="doi">10.1039/c005380p</pub-id><pub-id pub-id-type="pmid">20532370</pub-id></citation></ref>
<ref id="B7">
<label>7.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wilhelm</surname> <given-names>E</given-names></name> <name><surname>Neumann</surname> <given-names>C</given-names></name> <name><surname>Duttenhofer</surname> <given-names>T</given-names></name> <name><surname>Pires</surname> <given-names>L</given-names></name> <name><surname>Rapp</surname> <given-names>BE</given-names></name></person-group>. <article-title>Connecting microfluidic chips using a chemically inert, reversible, multichannel chip-to-world-interface</article-title>. <source>Lab Chip.</source> (<year>2013</year>) <volume>13</volume>:<fpage>4343</fpage>. <pub-id pub-id-type="doi">10.1039/c3lc50861g</pub-id><pub-id pub-id-type="pmid">24056989</pub-id></citation></ref>
<ref id="B8">
<label>8.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fernandes</surname> <given-names>AC</given-names></name> <name><surname>Gernaey</surname> <given-names>KV</given-names></name> <name><surname>Kr&#x000FC;hne</surname> <given-names>U</given-names></name></person-group>. <article-title>&#x0201C;Connecting worlds &#x02013; a view on microfluidics for a wider application</article-title>.&#x0201D; <italic>Biotechnol Adv</italic>. (<year>2018</year>) <volume>36</volume>:<fpage>1341</fpage>&#x02013;<lpage>66</lpage>. <pub-id pub-id-type="doi">10.1016/j.biotechadv.2018.05.001</pub-id><pub-id pub-id-type="pmid">29733891</pub-id></citation></ref>
<ref id="B9">
<label>9.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>van Swaay</surname> <given-names>D</given-names></name> <name><surname>M&#x000E4;chler</surname> <given-names>J-P</given-names></name> <name><surname>Stanley</surname> <given-names>C</given-names></name> <name><surname>deMello</surname> <given-names>A</given-names></name></person-group>. <article-title>A chip-to-world connector with a built-in reservoir for simple small-volume sample injection</article-title>. <source>Lab Chip.</source> (<year>2014</year>) <volume>14</volume>:<fpage>178</fpage>&#x02013;<lpage>81</lpage>. <pub-id pub-id-type="doi">10.1039/C3LC51065D</pub-id><pub-id pub-id-type="pmid">24226110</pub-id></citation></ref>
<ref id="B10">
<label>10.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bengtsson</surname> <given-names>K</given-names></name> <name><surname>Christoffersson</surname> <given-names>J</given-names></name> <name><surname>Mandenius</surname> <given-names>C-F</given-names></name> <name><surname>Robinson</surname> <given-names>ND</given-names></name></person-group>. <article-title>A clip-on electroosmotic pump for oscillating flow in microfluidic cell culture devices</article-title>. <source>Microfluid Nanofluid.</source> (<year>2018</year>) <volume>22</volume>:<fpage>27</fpage>. <pub-id pub-id-type="doi">10.1007/s10404-018-2046-4</pub-id></citation>
</ref>
<ref id="B11">
<label>11.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ackermann</surname> <given-names>TN</given-names></name> <name><surname>Gim&#x000E9;nez-G&#x000F3;mez</surname> <given-names>P</given-names></name> <name><surname>Mu&#x000F1;oz-Berbel</surname> <given-names>X</given-names></name> <name><surname>Llobera</surname> <given-names>A</given-names></name></person-group>. <article-title>Plug and measure &#x02013; a chip-to-world interface for photonic lab-on-a-chip applications</article-title>. <source>Lab Chip.</source> (<year>2016</year>) <volume>16</volume>:<fpage>3220</fpage>&#x02013;<lpage>6</lpage>. <pub-id pub-id-type="doi">10.1039/C6LC00462H</pub-id><pub-id pub-id-type="pmid">27428056</pub-id></citation></ref>
<ref id="B12">
<label>12.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Finkbeiner</surname> <given-names>T</given-names></name> <name><surname>Soergel</surname> <given-names>HL</given-names></name> <name><surname>Koschitzky</surname> <given-names>MP</given-names></name> <name><surname>Ahrens</surname> <given-names>R</given-names></name> <name><surname>Guber</surname> <given-names>AE</given-names></name></person-group>. <article-title>Ultrasonic welding for the rapid integration of fluidic connectors into microfluidic chips</article-title>. <source>J Micromech Microeng.</source> (<year>2019</year>) <volume>29</volume>:<fpage>065011</fpage>. <pub-id pub-id-type="doi">10.1088/1361-6439/ab10d2</pub-id></citation>
</ref>
<ref id="B13">
<label>13.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Liu</surname> <given-names>J</given-names></name> <name><surname>Hansen</surname> <given-names>C</given-names></name> <name><surname>Quake</surname> <given-names>SR</given-names></name></person-group>. <article-title>Solving the &#x0201C;World-to-Chip&#x0201D; interface problem with a microfluidic matrix</article-title>. <source>Anal Chem.</source> (<year>2003</year>) <volume>75</volume>:<fpage>4718</fpage>&#x02013;<lpage>23</lpage>. <pub-id pub-id-type="doi">10.1021/ac0346407</pub-id><pub-id pub-id-type="pmid">14674446</pub-id></citation></ref>
<ref id="B14">
<label>14.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>van Heeren</surname> <given-names>H</given-names></name></person-group>. <article-title>Standards for connecting microfluidic devices?</article-title> <source>Lab Chip.</source> (<year>2012</year>) <volume>12</volume>:<fpage>1022</fpage>&#x02013;<lpage>5</lpage>. <pub-id pub-id-type="doi">10.1039/c2lc20937c</pub-id><pub-id pub-id-type="pmid">22298257</pub-id></citation></ref>
<ref id="B15">
<label>15.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Moon</surname> <given-names>B-U</given-names></name> <name><surname>Clime</surname> <given-names>L</given-names></name> <name><surname>Brassard</surname> <given-names>D</given-names></name> <name><surname>Boutin</surname> <given-names>A</given-names></name> <name><surname>Daoud</surname> <given-names>J</given-names></name> <name><surname>Morton</surname> <given-names>K</given-names></name> <etal/></person-group>. <article-title>An automated centrifugal microfluidic assay for whole blood fractionation and isolation of multiple cell populations using an aqueous two-phase system</article-title>. <source>Lab Chip.</source> (<year>2021</year>) <volume>21</volume>:<fpage>4060</fpage>&#x02013;<lpage>70</lpage>. <pub-id pub-id-type="doi">10.1039/D1LC00680K</pub-id><pub-id pub-id-type="pmid">34604897</pub-id></citation></ref>
<ref id="B16">
<label>16.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fan</surname> <given-names>Y-Q</given-names></name> <name><surname>Wang</surname> <given-names>H-L</given-names></name> <name><surname>Gao</surname> <given-names>K-X</given-names></name> <name><surname>Liu</surname> <given-names>J-J</given-names></name> <name><surname>Chai</surname> <given-names>D-P</given-names></name> <name><surname>Zhang</surname> <given-names>Y-J</given-names></name></person-group>. <article-title>Applications of modular microfluidics technology</article-title>. <source>Chin J Anal Chem.</source> (<year>2018</year>) <volume>46</volume>:<fpage>1863</fpage>&#x02013;<lpage>71</lpage>. <pub-id pub-id-type="doi">10.1016/S1872-2040(18)61126-0</pub-id></citation>
</ref>
<ref id="B17">
<label>17.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hua</surname> <given-names>Z</given-names></name> <name><surname>Rouse</surname> <given-names>JL</given-names></name> <name><surname>Eckhardt</surname> <given-names>AE</given-names></name> <name><surname>Srinivasan</surname> <given-names>V</given-names></name> <name><surname>Pamula</surname> <given-names>VK</given-names></name> <name><surname>Schell</surname> <given-names>WA</given-names></name> <etal/></person-group>. <article-title>Multiplexed real-time polymerase chain reaction on a digital microfluidic platform</article-title>. <source>Anal Chem.</source> (<year>2010</year>) <volume>82</volume>:<fpage>2310</fpage>&#x02013;<lpage>6</lpage>. <pub-id pub-id-type="doi">10.1021/ac902510u</pub-id><pub-id pub-id-type="pmid">20151681</pub-id></citation></ref>
<ref id="B18">
<label>18.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gong</surname> <given-names>H</given-names></name> <name><surname>Woolley</surname> <given-names>AT</given-names></name> <name><surname>Nordin</surname> <given-names>GP</given-names></name></person-group>. <article-title>3D printed high density, reversible, chip-to-chip microfluidic interconnects</article-title>. <source>Lab Chip.</source> (<year>2018</year>) <volume>18</volume>:<fpage>639</fpage>&#x02013;<lpage>47</lpage>. <pub-id pub-id-type="doi">10.1039/C7LC01113J</pub-id><pub-id pub-id-type="pmid">29355276</pub-id></citation></ref>
<ref id="B19">
<label>19.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Agarwal</surname> <given-names>A</given-names></name> <name><surname>Goss</surname> <given-names>JA</given-names></name> <name><surname>Cho</surname> <given-names>A</given-names></name> <name><surname>McCain</surname> <given-names>ML</given-names></name> <name><surname>Parker</surname> <given-names>KK</given-names></name></person-group>. <article-title>Microfluidic heart on a chip for higher throughput pharmacological studies</article-title>. <source>Lab Chip.</source> (<year>2013</year>) <volume>13</volume>:<fpage>3599</fpage>&#x02013;<lpage>608</lpage>. <pub-id pub-id-type="doi">10.1039/c3lc50350j</pub-id><pub-id pub-id-type="pmid">23807141</pub-id></citation></ref>
<ref id="B20">
<label>20.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Nie</surname> <given-names>M</given-names></name> <name><surname>Takeuchi</surname> <given-names>S</given-names></name></person-group>. <article-title>Luer-lock valve: a pre-fabricated pneumatic valve for 3D printed microfluidic automation</article-title>. <source>Biomicrofluidics.</source> (<year>2020</year>) <volume>14</volume>:<fpage>044115</fpage>. <pub-id pub-id-type="doi">10.1063/5.0020531</pub-id><pub-id pub-id-type="pmid">32849974</pub-id></citation></ref>
<ref id="B21">
<label>21.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Reyes</surname> <given-names>DR</given-names></name> <name><surname>van Heeren</surname> <given-names>H</given-names></name></person-group>. <article-title>Proceedings of the first workshop on standards for microfluidics</article-title>. <source>J Res Natl Inst Stand Technol.</source> (<year>2019</year>) <volume>124</volume>:<fpage>1</fpage>&#x02013;<lpage>22</lpage>. <pub-id pub-id-type="doi">10.6028/jres.124.001</pub-id><pub-id pub-id-type="pmid">34877172</pub-id></citation></ref>
<ref id="B22">
<label>22.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Au</surname> <given-names>AK</given-names></name> <name><surname>Bhattacharjee</surname> <given-names>N</given-names></name> <name><surname>Horowitz</surname> <given-names>LF</given-names></name> <name><surname>Chang</surname> <given-names>TC</given-names></name> <name><surname>Folch</surname> <given-names>A</given-names></name></person-group>. <article-title>3D-printed microfluidic automation</article-title>. <source>Lab Chip.</source> (<year>2015</year>) <volume>15</volume>:<fpage>1934</fpage>&#x02013;<lpage>41</lpage>. <pub-id pub-id-type="doi">10.1039/C5LC00126A</pub-id><pub-id pub-id-type="pmid">25738695</pub-id></citation></ref>
<ref id="B23">
<label>23.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dekker</surname> <given-names>S</given-names></name> <name><surname>Buesink</surname> <given-names>W</given-names></name> <name><surname>Blom</surname> <given-names>M</given-names></name> <name><surname>Alessio</surname> <given-names>M</given-names></name> <name><surname>Verplanck</surname> <given-names>N</given-names></name> <name><surname>Hihoud</surname> <given-names>M</given-names></name> <etal/></person-group>. <article-title>Standardized and modular microfluidic platform for fast Lab on Chip system development</article-title>. <source>Sens Actuators B Chem.</source> (<year>2018</year>) <volume>272</volume>:<fpage>468</fpage>&#x02013;<lpage>78</lpage>. <pub-id pub-id-type="doi">10.1016/j.snb.2018.04.005</pub-id></citation>
</ref>
<ref id="B24">
<label>24.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ren</surname> <given-names>K</given-names></name> <name><surname>Zhou</surname> <given-names>J</given-names></name> <name><surname>Wu</surname> <given-names>H</given-names></name></person-group>. <article-title>Materials for microfluidic chip fabrication</article-title>. <source>Acc Chem Res.</source> (<year>2013</year>) <volume>46</volume>:<fpage>2396</fpage>&#x02013;<lpage>406</lpage>. <pub-id pub-id-type="doi">10.1021/ar300314s</pub-id><pub-id pub-id-type="pmid">24245999</pub-id></citation></ref>
<ref id="B25">
<label>25.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Roy</surname> <given-names>S</given-names></name> <name><surname>Yue</surname> <given-names>CY</given-names></name> <name><surname>Lam</surname> <given-names>YC</given-names></name> <name><surname>Wang</surname> <given-names>ZY</given-names></name> <name><surname>Hu</surname> <given-names>H</given-names></name></person-group>. <article-title>Surface analysis, hydrophilic enhancement, ageing behavior and flow in plasma modified cyclic olefin copolymer (COC)-based microfluidic devices</article-title>. <source>Sens Actuators B Chem.</source> (<year>2010</year>) <volume>150</volume>:<fpage>537</fpage>&#x02013;<lpage>49</lpage>. <pub-id pub-id-type="doi">10.1016/j.snb.2010.08.043</pub-id></citation>
</ref>
<ref id="B26">
<label>26.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Nunes</surname> <given-names>PS</given-names></name> <name><surname>Ohlsson</surname> <given-names>PD</given-names></name> <name><surname>Ordeig</surname> <given-names>O</given-names></name> <name><surname>Kutter</surname> <given-names>JP</given-names></name></person-group>. <article-title>Cyclic olefin polymers: emerging materials for lab-on-a-chip applications</article-title>. <source>Microfluidics Nanofluidics.</source> (<year>2010</year>) <volume>9</volume>:<fpage>145</fpage>&#x02013;<lpage>61</lpage>. <pub-id pub-id-type="doi">10.1007/s10404-010-0605-4</pub-id></citation>
</ref>
<ref id="B27">
<label>27.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lee</surname> <given-names>UN</given-names></name> <name><surname>Su</surname> <given-names>X</given-names></name> <name><surname>Guckenberger</surname> <given-names>DJ</given-names></name> <name><surname>Dostie</surname> <given-names>AM</given-names></name> <name><surname>Zhang</surname> <given-names>T</given-names></name> <name><surname>Berthier</surname> <given-names>E</given-names></name> <etal/></person-group>. <article-title>Fundamentals of rapid injection molding for microfluidic cell-based assays</article-title>. <source>Lab Chip.</source> (<year>2018</year>) <volume>18</volume>:<fpage>496</fpage>&#x02013;<lpage>504</lpage>. <pub-id pub-id-type="doi">10.1039/C7LC01052D</pub-id><pub-id pub-id-type="pmid">29309079</pub-id></citation></ref>
<ref id="B28">
<label>28.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ma</surname> <given-names>X</given-names></name> <name><surname>Li</surname> <given-names>R</given-names></name> <name><surname>Jin</surname> <given-names>Z</given-names></name> <name><surname>Fan</surname> <given-names>Y</given-names></name> <name><surname>Zhou</surname> <given-names>X</given-names></name> <name><surname>Zhang</surname> <given-names>Y</given-names></name></person-group>. <article-title>Injection molding and characterization of PMMA-based microfluidic devices</article-title>. <source>Microsyst Technol.</source> (<year>2020</year>) <volume>26</volume>:<fpage>1317</fpage>&#x02013;<lpage>24</lpage>. <pub-id pub-id-type="doi">10.1007/s00542-019-04662-2</pub-id></citation>
</ref>
<ref id="B29">
<label>29.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>ISO</surname> <given-names>80369-7</given-names></name></person-group>. (<year>2021</year>). <article-title>Small-bore connectors for liquids and gases in healthcare applications &#x02014; Part 7: Connectors for intravascular or hypodermic applications</article-title>.</citation>
</ref>
<ref id="B30">
<label>30.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pajouhi</surname> <given-names>H</given-names></name> <name><surname>Mohajerzadeh</surname> <given-names>S</given-names></name> <name><surname>Nayeri</surname> <given-names>F</given-names></name> <name><surname>Sanaee</surname> <given-names>Z</given-names></name></person-group>. <article-title>Deep micro-machining of poly-ethylene terephthalate for plastic MEMS applications</article-title>. <source>Solid State Electron.</source> (<year>2010</year>) <volume>54</volume>:<fpage>1536</fpage>&#x02013;<lpage>42</lpage>. <pub-id pub-id-type="doi">10.1016/j.sse.2010.07.020</pub-id></citation>
</ref>
<ref id="B31">
<label>31.</label>
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Thiruchitrambalam</surname> <given-names>M</given-names></name> <name><surname>Bubesh Kumar</surname> <given-names>D</given-names></name> <name><surname>Shanmugam</surname> <given-names>D</given-names></name> <name><surname>Jawaid</surname> <given-names>M</given-names></name></person-group>. <article-title>A review on PEEK composites &#x02013; Manufacturing methods, properties and applications</article-title>. <source>Mater Today Proc.</source> (<year>2020</year>) <volume>33</volume>:<fpage>1085</fpage>&#x02013;<lpage>92</lpage>. <pub-id pub-id-type="doi">10.1016/j.matpr.2020.07.124</pub-id></citation>
</ref>
</ref-list> 
</back>
</article> 