<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="research-article" dtd-version="2.3" xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Mater.</journal-id>
<journal-title>Frontiers in Materials</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Mater.</abbrev-journal-title>
<issn pub-type="epub">2296-8016</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">1213163</article-id>
<article-id pub-id-type="doi">10.3389/fmats.2023.1213163</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Materials</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>A comparative study of Sr-loaded nano-textured Ti and TiO<sub>2</sub> nanotube implants on osseointegration immediately after tooth extraction in Beagle dogs</article-title>
<alt-title alt-title-type="left-running-head">Li et al.</alt-title>
<alt-title alt-title-type="right-running-head">
<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3389/fmats.2023.1213163">10.3389/fmats.2023.1213163</ext-link>
</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Li</surname>
<given-names>Yongfeng</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1951357/overview"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Tang</surname>
<given-names>Li</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Shen</surname>
<given-names>Mingming</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Wang</surname>
<given-names>Zhen</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Huang</surname>
<given-names>Xiaofeng</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
</contrib>
</contrib-group>
<aff id="aff1">
<sup>1</sup>
<institution>Department of Stomatology</institution>, <institution>Beijing Friendship Hospital</institution>, <institution>Capital Medical University</institution>, <addr-line>Beijing</addr-line>, <country>China</country>
</aff>
<aff id="aff2">
<sup>2</sup>
<institution>School of Stomatology</institution>, <institution>Qingdao University</institution>, <addr-line>Qingdao</addr-line>, <country>China</country>
</aff>
<author-notes>
<fn fn-type="edited-by">
<p>
<bold>Edited by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1550057/overview">Yanjin Lu</ext-link>, Chinese Academy of Sciences (CAS), China</p>
</fn>
<fn fn-type="edited-by">
<p>
<bold>Reviewed by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1031140/overview">Qiang Wang</ext-link>, China Medical University, China</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/2255943/overview">Jinxin Lin</ext-link>, Fujian Normal University, China</p>
</fn>
<corresp id="c001">&#x2a;Correspondence: Xiaofeng Huang, <email>xiaofengh@ccmu.edu.cn</email>
</corresp>
</author-notes>
<pub-date pub-type="epub">
<day>13</day>
<month>07</month>
<year>2023</year>
</pub-date>
<pub-date pub-type="collection">
<year>2023</year>
</pub-date>
<volume>10</volume>
<elocation-id>1213163</elocation-id>
<history>
<date date-type="received">
<day>27</day>
<month>04</month>
<year>2023</year>
</date>
<date date-type="accepted">
<day>13</day>
<month>06</month>
<year>2023</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2023 Li, Tang, Shen, Wang and Huang.</copyright-statement>
<copyright-year>2023</copyright-year>
<copyright-holder>Li, Tang, Shen, Wang and Huang</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<p>Dental implantation, when performed immediately after tooth extraction, simplifies the treatment procedure, resulting in satisfaction for dentists and patients. Dental implants with nanotopography surface modification have been used to promote osseointegration immediately after implantation. We compared two different nanotopography surface implants on the effects of osseointegration immediately after tooth extraction: TiO<sub>2</sub> nanotubes (NT-TiO<sub>2</sub>) fabricated by anodization and Sr-loaded nanotopography Ti (NT-Sr) formed via magnetron sputtering technology. Sr-loaded nanotextured Ti nanotubes (NT-Sr) were fabricated via magnetron sputtering using 99.99% SrTiO<sub>3</sub> as the sputtering target. TiO<sub>2</sub> nanotubes (NT-TiO<sub>2</sub>) were fabricated by anodization in 0.5&#xa0;wt% hydrofluoric acid (HF). After the surface topography, hydrophilicity, chemical components, and interface bonding strength were analyzed, two different nano-topographies were applied for <italic>in vivo</italic> cellular activity evaluation. Subsequently, the implants with NT-Sr and NT-TiO<sub>2</sub> surfaces were inserted into the fresh socket immediately after tooth extraction. Radiological scanning, histological analysis, and biomechanical tests were carried out to investigate implant osseointegration. The results showed that nanotubes with diameters of 15&#x2013;80&#xa0;nm were distributed on the NT-TiO<sub>2</sub> surface, while the NT-Sr group showed 20&#x2013;40&#xa0;nm nanoparticles deposited on the surface. Compared to NT-Sr, the NT-TiO<sub>2</sub> surface possessed better hydrophilicity and favorable cellular adhesion and proliferation. The NT-Sr surface possessed greater interfacial bonding strength than the NT-TiO<sub>2</sub> group, and greater bone formation, higher bone-to-implant contact (BIC%), and maximum pull-out force were observed in the NT-Sr group. The above results indicated that although the NT-TiO<sub>2</sub> surface showed favorable <italic>in vitro</italic> bioactivity, the NT-Sr surface, with higher interface bonding strength, showed better <italic>in vitro</italic> osteogenesis, and would be more favorable for immediate implantation.</p>
</abstract>
<kwd-group>
<kwd>strontium</kwd>
<kwd>nano</kwd>
<kwd>magnetron sputtering</kwd>
<kwd>osseointegration</kwd>
<kwd>surface modification</kwd>
<kwd>immediate implantation</kwd>
</kwd-group>
<custom-meta-wrap>
<custom-meta>
<meta-name>section-at-acceptance</meta-name>
<meta-value>Biomaterials and Bio-Inspired Materials</meta-value>
</custom-meta>
</custom-meta-wrap>
</article-meta>
</front>
<body>
<sec id="s1">
<title>1 Introduction</title>
<p>Immediate implant placement after tooth extraction has led to much satisfaction for dentists and patients over the past decades (<xref ref-type="bibr" rid="B17">Seyssens et al., 2022</xref>). Compared to traditional delayed implantation, immediate implants can simplify the treatment procedure. In addition, immediate implantation is favorable for preservation of the extraction site and decreases alveolar bone resorption (<xref ref-type="bibr" rid="B1">Ara&#xfa;jo et al., 2019</xref>). In order to attain comparable long-term clinical efficacy to delayed implantation, immediate implantation demands higher yields of early osteogenic ability around the implant and higher initial stability. Various strategies have been developed to achieve early osteogenesis and initial stability during immediate implantation, including implant thread optimization and implant surface roughening. Previous studies have demonstrated that rough implant surface modifications can induce osteogenesis around the implant and subsequently stabilize osteointegration (<xref ref-type="bibr" rid="B16">Robo et al., 2022</xref>). To date, the conventional topography of commercial implant is almost at the micro-scale (1&#x2013;10&#xa0;&#x3bc;m). At present, nano scale surface (1&#x2013;100&#xa0;nm) modification has received significant attention, owing to its favorable biological reaction compared to micro-scale surface implants (<xref ref-type="bibr" rid="B12">Mendon&#xe7;a et al., 2008</xref>; <xref ref-type="bibr" rid="B3">Cavalu et al., 2020</xref>).</p>
<p>Previous studies have reported that a nanotopography surface promotes the osteointegration of implants. Nanotopography structures are classified, according to their topography, as nanoparticles, nanotubes, nanofibers (<xref ref-type="bibr" rid="B12">Mendon&#xe7;a et al., 2008</xref>; <xref ref-type="bibr" rid="B23">Yeo, 2019</xref>), and so on. An <italic>in vitro</italic> study conducted by Long <italic>et al.</italic> reported that titanium dioxide (TiO<sub>2</sub>) nanotubes can create a favorable osteoimmunomodulatory environment for bone regeneration and osseointegration (<xref ref-type="bibr" rid="B2">Bai et al., 2021</xref>). Parnia found that dental implants with nanoparticle coatings possess enhanced osseointegration and antimicrobial properties (<xref ref-type="bibr" rid="B4">Feridoun et al., 2017</xref>). Our previous studies have demonstrated that strontium (Sr)-loaded nanoparticle surfaces can promote osteogenesis in cellular and animal experiments under normal and osteoporotic conditions. However, surface roughness modification is a double-edged sword; an active roughness surface may decrease the coating interface bonding strength of the implant. Therefore, it is meaningful to fabricate surfaces possessing the dual properties of high coating interface bonding strength and active osteogenic ability. Few studies have investigated the effects of different nanotopographic surfaces on osseointegration in immediate implantation, especially when applied to large animal models.</p>
<p>Therefore, this study was performed to compare effects of two different typical nanotopographic surfaces on osseointegration during immediate implantation: Sr-loaded nanotextured Ti nanotubes (NT-Sr) and TiO<sub>2</sub> nanotubes (NT-TiO<sub>2</sub>).</p>
</sec>
<sec sec-type="materials|methods" id="s2">
<title>2 Materials and methods</title>
<sec id="s2-1">
<title>2.1 Sample coating fabrication and investigation</title>
<p>Titanium disks (<italic>&#x3a6;</italic> 15&#xa0;mm &#xd7; 1&#xa0;mm) and titanium screw implants (<italic>&#x3a6;</italic> 4&#xa0;mm &#xd7; 8&#xa0;mm) were randomly divided into two groups. The NT-TiO<sub>2</sub> implant group was prepared via anodization in a 0.5% (w/v) hydrofluoric (HF) acid electrolyte solution for 30&#xa0;min, using a 20&#xa0;V direct current (DC) power supply, and a platinum electrode as the cathode. NT-Sr group implants were fabricated via magnetron sputtering using an industrial physical vapor deposition (PVD) system. The films were deposited under the following conditions: Ar<sub>2</sub> gas composition at 0.5&#xa0;Pa. After fabrication, all samples were cleaned sequentially with acetone, ethanol, and deionized water ultrasonically, and finally sterilized with &#x3b3; irradiation for subsequent testing. The samples were tested using field-emission scanning electron microscopy (FE-SEM, HITACHI S-4800) to observe the surface topography and X-ray photoelectron spectroscopy (XPS, ESCALB MK-II) for chemical component analysis.</p>
<p>The interfacial bonding strength of nanotopography layers was evaluated using an epoxy resin docking tensile test, and the Ti samples after epoxy resin docking tensile testing were investigated using SEM to evaluate the collapsed surface characteristics. The surface hydrophilicity of the Ti samples was measured using a surface contact angle measurement machine (DSA30; Kruss, Germany).</p>
<p>The Sr release experiment was carried out using the following procedures: NT-Sr samples were immersed in 5&#xa0;mL phosphate buffer solution (PBS, Gibco) at 37&#xb0;C. The PBS was collected and replaced with fresh PBS after 1, 4, 7, and 14&#xa0;days. The PBS solution containing released Sr was analyzed using inductively coupled plasma atomic emission spectrometry (ICP-AES; IRIS Advantage ER/S). The NT-Sr samples were completely dissolved in a HNO<sub>3</sub> and HF mixture with ultrasonic treatment at room temperature. The total amount of Sr was determined using ICP-AES.</p>
</sec>
<sec id="s2-2">
<title>2.2 <italic>In vitro</italic> cellular assay</title>
<p>The murine MC3T3-E1 osteoblast cell line was used for co-culture with Ti samples. The cells were cultured in &#x3b1; minimum essential medium (&#x3b1;-MEM, Gibco) containing 10% fetal calf serum (FCS, Gibco) at 37&#xb0;C, with the medium changed every 3&#xa0;days. The Ti samples were placed in a 24-well plate and the cells were seeded at a density of 2 &#xd7; 10<sup>4</sup> cells/mL for the assays.</p>
<p>Cell adhesion analysis was carried out after incubation for 30, 60, and 120 min; the attached cells were stained using 4&#x2032;,6&#x2032;-diamidino-2-phenylindole (DAPI) (Sigma-Aldrich Co., St Louis, MO, United States). Positive cells were counted under an optical microscope (Olympus FluoView FV1000).</p>
<p>Cell proliferation was assessed after culturing for 1, 4, and 7&#xa0;days using a 3-(4,5-dimethylthiazol-2-yl)-2, 5-diphenyltetrazolium bromide (MTT) (Sigma-Aldrich Co.) assay. At prescribed time points, the Ti samples were gently rinsed with PBS and transferred to a new plate. The Ti samples were then incubated with the MTT solution at 37&#xb0;C for 4&#xa0;h. The formazan was then dissolved in dimethyl sulfoxide, and the optical density was measured at 490&#xa0;nm using a spectrophotometer (Bio-Tek).</p>
<p>Alkaline phosphatase activity (ALP) analysis was performed after 7&#xa0;days in culture. A colorimetric assay was used to determine the quantity of ALP present. This assay was based on an ALP reagent containing p-nitrophenyl phosphate (p-NPP) as the substrate. Moreover, cell morphology observation after incubation for 3&#xa0;days was carried out to compare the <italic>in vitro</italic> cellular activity of the two nano-texture surfaces. After incubation for 3&#xa0;days, the samples with attached cells were fixed in 3% glutaraldehyde, dehydrated in a graded ethanol series, freeze dried, sputter coated with gold, and observed using FE-SEM. The details of the above <italic>in vitro</italic> cellular assay complied with our previous study (<xref ref-type="bibr" rid="B7">Li et al., 2015</xref>).</p>
</sec>
<sec id="s2-3">
<title>2.3 <italic>In vivo</italic> experiment</title>
<sec id="s2-3-1">
<title>2.3.1 Animals and surgical procedures</title>
<p>Eight 2-year-old beagles were included in our study. The study was approved and supervised by the Laboratory Animal Ethical Inspection, School of the Fourth Military Medical University [Xi&#x2019;an, China; approval document no. 2014 (058)]. Adequate measures were taken to minimize pain and discomfort in animals. Animals were anesthetized with sodium pentobarbital (30&#xa0;mg/kg; Merck Drugs and Biotechnology). The two different surface implants were inserted into fresh extraction sockets immediately after bilateral mandibular premolar extraction. The NT-TiO<sub>2</sub> implants were implanted on the left side, and the NT-Sr implants on the right. The gaps between the implants and extraction sockets were filled with autologous bone chips and X-ray scanning (IntraOs 70, Blue X, Assago, Italy) was performed before teeth extraction, post-extraction, and post-implantation. Antibiotics (ampicillin, 0.5&#xa0;mg/kg, China) were administered for 5&#xa0;days to prevent infection post-operation, mouth care with normal saline rinsing was performed for 1&#xa0;week, and a semi-fluid diet was fed to avoid excessive occlusal force. Twelve weeks after implantation, all animals were euthanized according to the following procedures: overanesthesia with pentobarbital (3%, 100&#xa0;mg/kg) intravenous injection was applied before harvesting, after vital signs including breathing and heart rate were not detected and tongue cyanosis observed. Mandibles with implants were harvested for subsequent testing. Calcein (8&#xa0;mg&#xa0;kg<sup>&#x2212;1</sup>, Sigma Chemicals Co., United States) and tetracycline (50&#xa0;mg&#xa0;kg<sup>&#x2212;1</sup>, Amresco Ltd., United States) were administered via intramuscular injection on days 4 and 14 to evaluate new bone deposition.</p>
</sec>
<sec id="s2-3-2">
<title>2.3.2 Micro-CT scanning</title>
<p>After euthanasia, the samples were immersed in 75% alcohol and prepared for micro-CT scanning (Inveon, Siemens, Erlangen, Germany). A three-dimensional image was reconstructed using an isotropic voxel size of 15&#xa0;&#xb5;m. A region of interest (ROI) was defined as a ring 1&#xa0;mm in radius from the implant surface. Images acquired from the ROI were used for quantitative analysis, which included bone volume/total volume (BV/TV), trabecular number (Tb.N), trabecular thickness (Tb.Th), and trabecular separation (Tb.Sp).</p>
</sec>
<sec id="s2-3-3">
<title>2.3.3 Histological analysis</title>
<p>The samples were prepared for non-decalcified sections after micro-CT scanning. The samples were immersed in 75% alcohol for 7&#xa0;days and then dehydrated using a graded series of dilutions of ethanol and 100% acetone. Samples were embedded in polyester resin and cut mid-axially into slices of 150&#xa0;&#x3bc;m, which were subsequently ground into 100&#xa0;&#xb5;m-thick slices using a sawing microtome (Leica SP 1600, Leica Microsystems). Images were captured using a fluorescence microscope (Leica).</p>
<p>After fluorescence observation, the sections were stained with methylene blue acid fuchsin and analyzed using a digitized image analysis system (Leica) coupled to a light microscope (Olympus). BIC% was calculated as the linear percentage of direct bone-to-implant contact relative to the total implant interface in the cancellous bone.</p>
</sec>
<sec id="s2-3-4">
<title>2.3.4 Biomechanical testing</title>
<p>After the specimens were harvested, eight samples from each group were immediately subjected to a biomechanical pull-out test using a universal material testing system (AGS-10KNG, Shimadzu, Japan). The speed was set at 2&#xa0;mm/min. The displacement&#x2013;force curve was recorded to calculate the maximum pull-out force.</p>
</sec>
</sec>
<sec id="s2-4">
<title>2.4 Statistical analysis</title>
<p>Data analysis was performed using the Statistical Package for the Social Sciences (SPSS, version 18). A paired-samples <italic>t-test</italic> was applied for comparisons between two groups. All data are expressed as the mean &#xb1; standard deviation (SD). Significant difference was defined as <italic>p</italic> &#x3c; 0.05, and highly significant differences as <italic>p</italic> &#x3c; 0.01.</p>
</sec>
</sec>
<sec sec-type="results" id="s3">
<title>3 Results</title>
<sec id="s3-1">
<title>3.1 Surface characterization of the samples</title>
<p>SEM images clearly show the surface textures of the two different samples. Nanotubes with diameters of 15&#x2013;80&#xa0;nm were distributed on the NT-TiO<sub>2</sub> surface, whereas nanoparticles with diameters of 20&#x2013;40&#xa0;nm were deposited on the NT-Sr surface (<xref ref-type="fig" rid="F1">Figure 1</xref>). XPS results showed that Ti, O, and fluorine (F) elements were detected in the NT-TiO<sub>2</sub> samples. The XPS survey of the NT-Sr samples detected the presence of Ti, O, and Sr (<xref ref-type="fig" rid="F1">Figure 1</xref>).</p>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption>
<p>Surface characteristics evaluation of the two different samples. (<italic>n</italic> &#x3d; 8). Scale bar is 200&#xa0;nm. NT-TiO<sub>2</sub>, TiO<sub>2</sub> nanotubes surface; NT-Sr, nano strontium-containing titanium surface; SEM, scanning electron microscopy; XPS, X-ray photoelectron spectroscopy.</p>
</caption>
<graphic xlink:href="fmats-10-1213163-g001.tif"/>
</fig>
<p>The interface bonding strength of NT-Sr and NT-TiO<sub>2</sub> samples were 52.40 &#xb1; 8.73 MPa and 18.20 &#xb1; 4.16 MPa, respectively, and a significant difference existed between the groups. SEM images show that the nanotube structure disappeared and that only a residual nanopitted texture remained, whereas the NT-Sr sample displayed a few nanoparticle splits (<xref ref-type="fig" rid="F1">Figure 1</xref>). The contact angles of NT-TiO<sub>2</sub> and NT-Sr were 23.96&#xb0; &#xb1; 3.64&#xb0; and 29.76&#xb0; &#xb1; 5.18&#xb0;, respectively, which indicated that the NT-TiO<sub>2</sub> surface possessed better hydrophilicity than the NT-Sr surface (<xref ref-type="fig" rid="F1">Figure 1</xref>).</p>
<p>Furthermore, the initial Sr release occurred quickly and the release rate decreased with time. Seven days later, the Sr release rate was relatively constant (<xref ref-type="fig" rid="F2">Figure 2</xref>); the approximate amount of Sr released from NT-Sr samples daily was 0.0156 &#xb1; 0.0092&#xa0;&#x3bc;g/cm<sup>2</sup>. The total Sr content loaded on the NT-Sr surfaces was 42.08 &#xb1; 2.52&#xa0;&#x3bc;g. The results indicated that the total Sr content could be released continuously for over 1&#xa0;year.</p>
<fig id="F2" position="float">
<label>FIGURE 2</label>
<caption>
<p>Non-cumulative Sr release time profile for NT-Sr into PBS (<italic>n</italic> &#x3d; 5 at each time point).</p>
</caption>
<graphic xlink:href="fmats-10-1213163-g002.tif"/>
</fig>
</sec>
<sec id="s3-2">
<title>3.2 <italic>In vitro</italic> cellular assay</title>
<p>As shown in <xref ref-type="fig" rid="F3">Figure 3</xref>, the number of adherent cells on all the Ti samples increased from 30 to 120&#xa0;min, and the number of cells adhered on the NT-TiO<sub>2</sub> surface seemed to be higher than that on the NT-Sr group over the entire process.</p>
<fig id="F3" position="float">
<label>FIGURE 3</label>
<caption>
<p>
<italic>In vitro</italic> cellular activity evaluation of the two different samples. &#x2a;<italic>p</italic> &#x3c; 0.05 and &#x2a;&#x2a;<italic>p</italic> &#x3c; 0.01 compared to NT-TiO<sub>2</sub> samples. (<italic>n</italic> &#x3d; 6 at each time point). <bold>(A)</bold> SEM images of cellular adhesion on the two surfaces; <bold>(B)</bold> Cellular attachment on the two different samples; <bold>(C)</bold> Cellular proliferation after incubation for 1, 4, and 7&#xa0;days. <bold>(D)</bold> ALP activity for two samples. Scale bars: yellow scale bar &#x3d; 100&#xa0;&#x3bc;m, red scale bar &#x3d; 10&#xa0;&#x3bc;m, blue scale bar &#x3d; 2&#xa0;&#x3bc;m, green scale bar &#x3d; 200&#xa0;nm.</p>
</caption>
<graphic xlink:href="fmats-10-1213163-g003.tif"/>
</fig>
<p>Cell proliferation was evaluated using MTT assay (<xref ref-type="fig" rid="F3">Figure 3</xref>). The cells of the two groups proliferated well, with culture times of 1&#x2013;7&#xa0;days. On day 1, there was no discernible difference in cell proliferation among the different Ti samples. On days 4 and 7, the NT-TiO<sub>2</sub> samples showed better cell proliferation ability than the NT-Sr samples.</p>
<p>As shown in <xref ref-type="fig" rid="F3">Figure 3</xref>, high-magnification SEM images reveal that osteoblasts had spread on the NT-Sr and NT-TiO<sub>2</sub> surfaces. Compared with the cells grown on NT-Sr, the lamellipodia of the cells grown on NT-TiO<sub>2</sub> spread more smoothly.</p>
<p>Furthermore, the results in <xref ref-type="fig" rid="F3">Figure 3</xref> indicate that the NT-Sr group showed significantly better ALP activity after 7&#xa0;days in culture.</p>
</sec>
<sec id="s3-3">
<title>3.3 <italic>In vivo</italic> animal experiment</title>
<p>X-ray examination indicated that the teeth were extracted without additional trauma. Subsequently, the implants were inserted into the extraction socket, and the inferior alveolar neurovascular bundle was not injured (<xref ref-type="fig" rid="F4">Figure 4</xref>). No implant loss occurred after 3&#xa0;months of observation.</p>
<fig id="F4" position="float">
<label>FIGURE 4</label>
<caption>
<p>Procedure for immediate implantation and X-ray. <bold>(A1)</bold> before teeth extraction; <bold>(B1)</bold> after teeth extraction; <bold>(C1)</bold> immediately after implantation; <bold>(A2)</bold> X-ray before teeth extraction; <bold>(B2)</bold> X-ray after teeth extraction; <bold>(C2)</bold> X-ray immediately after implantation.</p>
</caption>
<graphic xlink:href="fmats-10-1213163-g004.tif"/>
</fig>
<p>The 3D reconstructed images from micro-CT are shown in <xref ref-type="fig" rid="F5">Figure 5</xref>, which depict bone remodeling around the implants. The bone volume of the NT-Sr group was higher than that of the NT-TiO<sub>2</sub> group. In the quantitative assessment, BV/TV, Tb.N, and Tb.Th were significantly higher for the NT-Sr group. Particularly, as the most important parameter reflecting bone remodeling, the BV/TV of the NT-Sr group increased 0.91-fold compared to the NT-TiO<sub>2</sub> group (<xref ref-type="table" rid="T1">Table 1</xref>).</p>
<fig id="F5" position="float">
<label>FIGURE 5</label>
<caption>
<p>Micro-CT scanning (<italic>n</italic> &#x3d; 10) and histological analysis (<italic>n</italic> &#x3d; 12) for evaluating osseointegration around the two different surface implants.</p>
</caption>
<graphic xlink:href="fmats-10-1213163-g005.tif"/>
</fig>
<table-wrap id="T1" position="float">
<label>TABLE 1</label>
<caption>
<p>Quantity analysis of trabecular bone from Micro-CT scanning for implantation immediately after teeth extraction &#x2a;<italic>p</italic> &#x3c; 0.05 and &#x2a;&#x2a;<italic>p</italic> &#x3c; 0.01 compared with NT-TiO<sub>2</sub> (<italic>n</italic> &#x3d; 10).</p>
</caption>
<table>
<thead valign="top">
<tr>
<th rowspan="2" align="center">Parameters</th>
<th colspan="2" align="center">Groups</th>
</tr>
<tr>
<th align="center">NT-TiO<sub>2</sub>
</th>
<th align="center">NT-Sr</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="center">BV/TV (%)</td>
<td align="center">28.79 &#xb1; 5.94</td>
<td align="center">54.95 &#xb1; 9.97&#x2a;&#x2a;</td>
</tr>
<tr>
<td align="center">Tb.N (1/mm)</td>
<td align="center">2.06 &#xb1; 0.76</td>
<td align="center">2.38 &#xb1; 0.46</td>
</tr>
<tr>
<td align="center">Tb.Th (&#xb5;m)</td>
<td align="center">131.6 &#xb1; 25.6</td>
<td align="center">204.9 &#xb1; 29.7&#x2a;&#x2a;</td>
</tr>
<tr>
<td align="center">Tb.Sp (&#xb5;m)</td>
<td align="center">315.2 &#xb1; 112.7</td>
<td align="center">196.7 &#xb1; 89.7&#x2a;</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>As shown in the fluorescence microscopy images (<xref ref-type="fig" rid="F5">Figure 5</xref>), the tissues labelled with calcein were observed with a green fluorescence marker, while those observed with a yellow fluorescence marker indicated tissues labelled with tetracycline; the markers were deposited along the implant surfaces. The mineral apposition ratio (MAR, &#x3bc;m/d) indicates the rate of new-bone mineralization, which is defined as the distance between two double-fluorescence markers. There were statistically significant differences in the MAR between the two groups, in the following order: NT-Sr &#x3e; NT-TiO<sub>2</sub> (<italic>p</italic> &#x3c; 0.01). Moreover, from images of the methylene blue/acid fuchsin staining, calcified bone was stained with its characteristic bright pink color and Ti implants were stained black on the slides (<xref ref-type="fig" rid="F5">Figure 5</xref>). One section from each specimen was used for the analysis, and the results of histomorphometry were expressed as BIC% (<xref ref-type="table" rid="T1">Table 1</xref>). Twelve weeks after implantation, the BIC% of the NT-TiO<sub>2</sub> and NT-Sr groups were 44.13% &#xb1; 6.2% and 76.63% &#xb1; 8.16%, respectively, and a significant statistical difference in BIC% existed between the two groups.</p>
<p>
<xref ref-type="table" rid="T2">Table 2</xref> lists the results of the maximal pull-out force of the two groups 12&#xa0;weeks after implantation. The pull-out force of the NT-Sr group was significantly higher than that of the NT-TiO<sub>2</sub> group (<italic>p</italic> &#x3c; 0.01).</p>
<table-wrap id="T2" position="float">
<label>TABLE 2</label>
<caption>
<p>Histological analysis and biomechanical test for evaluating osseointegration around two different surface implants: &#x2a;<italic>p</italic> &#x3c; 0.05 and &#x2a;&#x2a;<italic>p</italic> &#x3c; 0.01 compared with NT-TiO<sub>2</sub> (<italic>n</italic> &#x3d; 12).</p>
</caption>
<table>
<thead valign="top">
<tr>
<th rowspan="2" align="center">Parameters</th>
<th colspan="2" align="center">Groups</th>
</tr>
<tr>
<th align="center">NT-TiO<sub>2</sub>
</th>
<th align="center">NT-Sr</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="center">BIC (%)</td>
<td align="center">44.13 &#xb1; 6.2</td>
<td align="center">76.63 &#xb1; 8.16&#x2a;&#x2a;</td>
</tr>
<tr>
<td align="center">MAR (&#xb5;m/day)</td>
<td align="center">1.78 &#xb1; 0.55</td>
<td align="center">2.92 &#xb1; 0.58&#x2a;&#x2a;</td>
</tr>
<tr>
<td align="center">Maximal pullout force (N)</td>
<td align="center">236.50 &#xb1; 40.86</td>
<td align="center">342.75 &#xb1; 46.02&#x2a;&#x2a;</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
</sec>
<sec sec-type="discussion" id="s4">
<title>4 Discussion</title>
<p>Previous clinical and experimental studies have demonstrated that implants immediately inserted in fresh extraction sockets can prevent post-extraction bone loss. However, the immediate implantation strategy has two potential challenges: firstly, gaps between the regular implant and the irregular extraction socket prevent a part of the implant surface from making direct alveolar bone contact (<xref ref-type="bibr" rid="B13">Naji et al., 2021</xref>; <xref ref-type="bibr" rid="B19">Slagter et al., 2021</xref>). Secondly, unpredictable implant primary stability results from lower thread mechanical retention in the surrounding bone (<xref ref-type="bibr" rid="B6">Levin et al., 2021</xref>). Therefore, favorable osteogenic ability and primary stability are crucial for immediate implantation success.</p>
<p>Conventionally, the regions where the implant surface directly contacts the host bone facilitate favorable osseointegration, while the regions of mismatch gaps between the implant and extraction socket require better bone induction ability. Compared to micro-topography surfaces, nanotopography appears to positively affect cell behavior, including cell adhesion, spread, motility, and proliferation, and nanotopography can selectively adhered to osteoblasts (<xref ref-type="bibr" rid="B14">Price et al., 2003</xref>; <xref ref-type="bibr" rid="B11">McManus et al., 2005</xref>). For example, on nanosized materials, the affinity ratio between osteoblasts and fibroblasts was 3:1, but for conventional materials, the ratio was 1:1 (<xref ref-type="bibr" rid="B22">Webster et al., 2000</xref>). Nanotopography is crucial for osteogenesis between gaps in the implant surface, which can ensure that osteoblasts, instead of fibroblasts, occupy the gaps between the implant and extraction socket. Therefore, in this study, two typical nanotopographic surfaces, NT-Sr and NT-TiO<sub>2</sub>, were applied to promote osteogenesis around titanium implants. SEM imaging indicated that nanoparticles (20&#x2013;40&#xa0;nm) and nanotubes (15&#x2013;80&#xa0;nm), respectively, were fabricated on these titanium surfaces. Subsequent <italic>in vitro</italic> cellular assays showed a positive effect on cell adhesion, proliferation, and differentiation. Additionally, compared to the NT-Sr group, the NT-TiO<sub>2</sub> surface showed better cell adhesion and proliferation, which may be attributed to the superior hydrophilicity of the NT-TiO<sub>2</sub> surface. While higher ALP activity was observed on the NT-Sr surface, Sr loading may be one of the most important factors that influenced bone remodeling. Previous studies have demonstrated that strontium has dual effects on promoting osteogenesis: stimulation of osteoblast differentiation and inhibition of osteoclast functions (<xref ref-type="bibr" rid="B10">Marx et al., 2020</xref>). The osseointegration effect of strontium-loaded surfaces under normal and osteoporotic conditions was verified by <italic>in vitro</italic> and <italic>in vivo</italic> experiments (<xref ref-type="bibr" rid="B18">Shi et al., 2017</xref>; <xref ref-type="bibr" rid="B8">Liu et al., 2019</xref>; L&#xf3;pez-Valverde, Muriel-Fern&#xe1;ndez, G&#xf3;mez de Diego, Ram&#xed;rez, and; <xref ref-type="bibr" rid="B9">L&#xf3;pez-Valverde et al., 2019</xref>). Moreover, the Sr release assay used in this study detected continuous Sr release at a slow rate, which can ensure active osteogenesis and mineralization. A similar phenomenon was observed in the double fluorescence labelled results, which indicated that the NT-Sr surface possessed a better mineralization ability than the NT-TiO<sub>2</sub> surface.</p>
<p>The animal experiment investigated osseointegration around the implants, and reversed trends from the <italic>in vivo</italic> assay were observed in the two nanotopography groups: the BIC%, MAR, and maximum pull-out strength of the NT-Sr group were higher than those of the NT-TiO<sub>2</sub> group. This can be explained by the results of the epoxy resin docking tensile test, which indicated that the nanocoating interfacial bonding strength of the NT-TiO<sub>2</sub> surface was only 34.73% of that of the NT-Sr surface. SEM imaging after the epoxy resin docking tensile test also showed completely desquamated nanotubes, whereas the NT-Sr surface showed no obvious changes. In clinical practice, a greater range difference is applied to obtain primary stability during immediate implantation; hence, the solid bonding strength between the coating and the titanium substrates is of great importance. Once the coating collapses from the substrates during implant insertion, the free collapsed particles result in potential adverse inflammatory responses, peri-implantitis, and implant loosening. Potential systemic toxicity resulting from desquamate nanoparticles and debris has been reported in previous studies (<xref ref-type="bibr" rid="B5">Hoet et al., 2004</xref>; <xref ref-type="bibr" rid="B21">Warheit et al., 2004</xref>; <xref ref-type="bibr" rid="B24">Zeman et al., 2018</xref>). Therefore, the interfacial bonding strength of the implant and surface coating was comparable to that of the coating and surrounding bones. Considering the above issues, we fabricated a bioactive nanotopography surface using magnetron sputtering technology, which can synthesize highly adherent thin films via physical vapor deposition (PVD) (<xref ref-type="bibr" rid="B20">Stan et al., 2011</xref>) (<xref ref-type="bibr" rid="B15">Qadir et al., 2019</xref>).</p>
<p>The positive results of the NT-Sr surface in <italic>in vitro</italic> osseointegration satisfied the two main demands of immediate implantation mentioned above. Firstly, nanotopography and Sr loading can promote osteogenesis, which is needed to simultaneously perform implant insertion and tooth extraction. Secondly, a high interfacial bonding strength can resist the strength of a greater insertion force, which is required for better primary stability. Therefore, compared to the NT-TiO<sub>2</sub> surface, the NT-Sr surface is more suitable for immediate implantation.</p>
</sec>
<sec sec-type="conclusion" id="s5">
<title>5 Conclusion</title>
<p>Although we tried to take all aspects into consideration, limitations still inevitability existed, such as limited evaluation indicators and a short observation period. Nonetheless, we can conclude from our preliminary results that NT-TiO<sub>2</sub> and NT-Sr surfaces show favorable <italic>in vivo</italic> cellular activity. NT-TiO<sub>2</sub> possessed better cellular adhesion and proliferation due to its higher hydrophilicity. While NT-Sr surfaces with higher coating interfacial bonding strength would be more suitable for immediate implantation, Sr loading on the surface facilitating improved mineralization was another crucial factor.</p>
</sec>
</body>
<back>
<sec sec-type="data-availability" id="s6">
<title>Data availability statement</title>
<p>The original contributions presented in the study are included in the article/Supplementary material, further inquiries can be directed to the corresponding author.</p>
</sec>
<sec id="s7">
<title>Ethics statement</title>
<p>The animal study was reviewed and approved by the Laboratory Animal Ethical Inspection, School of the Fourth Military Medical University.</p>
</sec>
<sec id="s8">
<title>Author contributions</title>
<p>YL: conceptualization, investigation, writing-original draft. LT: investigation, data curation, visualization. MS: investigation, data curation, formal analysis. ZW: investigation, data curation, visualization. XH: conceptualization, revision, writing-review and editing, validation. All authors contributed to the article and approved the submitted version.</p>
</sec>
<sec sec-type="COI-statement" id="s9">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec sec-type="disclaimer" id="s10">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ref-list>
<title>References</title>
<ref id="B1">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ara&#xfa;jo</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Silva</surname>
<given-names>C. O.</given-names>
</name>
<name>
<surname>Souza</surname>
<given-names>A. B.</given-names>
</name>
<name>
<surname>Sukekava</surname>
<given-names>F.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Socket healing with and without immediate implant placement</article-title>. <source>Periodontol</source>. <volume>79</volume>,<fpage>168</fpage>&#x2013;<lpage>177</lpage>. <pub-id pub-id-type="doi">10.1111/prd.12252</pub-id>
</citation>
</ref>
<ref id="B2">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bai</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Zhao</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Huang</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Du</surname>
<given-names>Z.</given-names>
</name>
<etal/>
</person-group> (<year>2021</year>). <article-title>Targeting early healing phase with titania nanotube arrays on tunable diameters to accelerate bone regeneration and osseointegration</article-title>. <source>Small</source> <volume>17</volume>, <fpage>e2006287</fpage>. <pub-id pub-id-type="doi">10.1002/smll.202006287</pub-id>
</citation>
</ref>
<ref id="B3">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cavalu</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Antoniac</surname>
<given-names>I. V.</given-names>
</name>
<name>
<surname>Mohan</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Bodog</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Doicin</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Mates</surname>
<given-names>I.</given-names>
</name>
<etal/>
</person-group> (<year>2020</year>). <article-title>Nanoparticles and nanostructured surface fabrication for innovative cranial and maxillofacial surgery</article-title>. <source>Mater. (Basel)</source> <volume>13</volume>, <fpage>5391</fpage>. <pub-id pub-id-type="doi">10.3390/ma13235391</pub-id>
</citation>
</ref>
<ref id="B4">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Feridoun</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Javad</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Vahid</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Solmaz</surname>
<given-names>M. D.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Overview of nanoparticle coating of dental implants for enhanced osseointegration and antimicrobial purposes</article-title>. <source>J. Pharm. Pharm. Sci.</source> <volume>20</volume>, <fpage>148</fpage>&#x2013;<lpage>160</lpage>. <pub-id pub-id-type="doi">10.18433/J3GP6G</pub-id>
</citation>
</ref>
<ref id="B5">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hoet</surname>
<given-names>P. H.</given-names>
</name>
<name>
<surname>Br&#xfc;ske-Hohlfeld</surname>
<given-names>I.</given-names>
</name>
<name>
<surname>Salata</surname>
<given-names>O. V.</given-names>
</name>
</person-group> (<year>2004</year>). <article-title>Nanoparticles - known and unknown health risks</article-title>. <source>J. Nanobiotechnology.</source> <volume>2</volume>, <fpage>12</fpage>. <pub-id pub-id-type="doi">10.1186/1477-3155-2-12</pub-id>
</citation>
</ref>
<ref id="B6">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Levin</surname>
<given-names>B. P.</given-names>
</name>
<name>
<surname>Chu</surname>
<given-names>S. J.</given-names>
</name>
<name>
<surname>Saito</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Nevins</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Levin</surname>
<given-names>J. P.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>A novel implant design for immediate extraction sites: Determining primary stability</article-title>. <source>Int. J. Periodontics. Restor. Dent.</source> <volume>41</volume>, <fpage>357</fpage>&#x2013;<lpage>364</lpage>. <pub-id pub-id-type="doi">10.11607/prd.5527</pub-id>
</citation>
</ref>
<ref id="B7">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Li</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Qi</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Gao</surname>
<given-names>Q.</given-names>
</name>
<name>
<surname>Niu</surname>
<given-names>Q.</given-names>
</name>
<name>
<surname>Shen</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Fu</surname>
<given-names>Q.</given-names>
</name>
<etal/>
</person-group> (<year>2015</year>). <article-title>Effects of a micro/nano rough strontium-loaded surface on osseointegration</article-title>. <source>Int. J. Nanomedicine.</source> <volume>10</volume>, <fpage>4549</fpage>&#x2013;<lpage>4563</lpage>. <pub-id pub-id-type="doi">10.2147/IJN.S84398</pub-id>
</citation>
</ref>
<ref id="B8">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Liu</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Liang</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Sui</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Bellare</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Kong</surname>
<given-names>L.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Effects of micro/nano strontium-loaded surface implants on osseointegration in ovariectomized sheep</article-title>. <source>Clin. Implant. Dent. Relat. Res.</source> <volume>21</volume>, <fpage>377</fpage>&#x2013;<lpage>385</lpage>. <pub-id pub-id-type="doi">10.1111/cid.12719</pub-id>
</citation>
</ref>
<ref id="B9">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>L&#xf3;pez-Valverde</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Muriel-Fern&#xe1;ndez</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>G&#xf3;mez de Diego</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Ram&#xed;rez</surname>
<given-names>J. M.</given-names>
</name>
<name>
<surname>L&#xf3;pez-Valverde</surname>
<given-names>A.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Effect of strontium-coated titanium implants on osseointegration in animal models: A literature systematic review</article-title>. <source>Int. J. Oral. Maxillofac. Implants.</source> <volume>34</volume>, <fpage>1389</fpage>&#x2013;<lpage>1396</lpage>. <pub-id pub-id-type="doi">10.11607/jomi.7827</pub-id>
</citation>
</ref>
<ref id="B10">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Marx</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Rahimnejad Yazdi</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Papini</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Towler</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>A review of the latest insights into the mechanism of action of strontium in bone</article-title>. <source>Bone. Rep.</source> <volume>12</volume>, <fpage>100273</fpage>. <pub-id pub-id-type="doi">10.1016/j.bonr.2020.100273</pub-id>
</citation>
</ref>
<ref id="B11">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>McManus</surname>
<given-names>A. J.</given-names>
</name>
<name>
<surname>Doremus</surname>
<given-names>R. H.</given-names>
</name>
<name>
<surname>Siegel</surname>
<given-names>R. W.</given-names>
</name>
<name>
<surname>Bizios</surname>
<given-names>R.</given-names>
</name>
</person-group> (<year>2005</year>). <article-title>Evaluation of cytocompatibility and bending modulus of nanoceramic/polymer composites</article-title>. <source>J. Biomed. Mat. Res. A</source> <volume>72</volume>, <fpage>98</fpage>&#x2013;<lpage>106</lpage>. <pub-id pub-id-type="doi">10.1002/jbm.a.30204</pub-id>
</citation>
</ref>
<ref id="B12">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mendon&#xe7;a</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Mendon&#xe7;a</surname>
<given-names>D. B.</given-names>
</name>
<name>
<surname>Arag&#xe3;o</surname>
<given-names>F. J.</given-names>
</name>
<name>
<surname>Cooper</surname>
<given-names>L. F.</given-names>
</name>
</person-group> (<year>2008</year>). <article-title>Advancing dental implant surface technology-from micron-to nanotopography</article-title>. <source>Biomaterials</source> <volume>29</volume>, <fpage>3822</fpage>&#x2013;<lpage>3835</lpage>. <pub-id pub-id-type="doi">10.1016/j.biomaterials.2008.05.012</pub-id>
</citation>
</ref>
<ref id="B13">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Naji</surname>
<given-names>B. M.</given-names>
</name>
<name>
<surname>Abdelsameaa</surname>
<given-names>S. S.</given-names>
</name>
<name>
<surname>Alqutaibi</surname>
<given-names>A. Y.</given-names>
</name>
<name>
<surname>Said Ahmed</surname>
<given-names>W. M.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Immediate dental implant placement with a horizontal gap more than two millimetres: A randomized clinical trial</article-title>. <source>Int. J. Oral. Maxillofac. Surg.</source> <volume>50</volume>, <fpage>683</fpage>&#x2013;<lpage>690</lpage>. <pub-id pub-id-type="doi">10.1016/j.ijom.2020.08.015</pub-id>
</citation>
</ref>
<ref id="B14">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Price</surname>
<given-names>R. L.</given-names>
</name>
<name>
<surname>Gutwein</surname>
<given-names>L. G.</given-names>
</name>
<name>
<surname>Kaledin</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Tepper</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Webster</surname>
<given-names>T. J.</given-names>
</name>
</person-group> (<year>2003</year>). <article-title>Osteoblast function on nanophase alumina materials: Influence of chemistry, phase, and topography</article-title>. <source>J. Biomed. Mat. Res. A</source> <volume>67</volume>, <fpage>1284</fpage>&#x2013;<lpage>1293</lpage>. <pub-id pub-id-type="doi">10.1002/jbm.a.20011</pub-id>
</citation>
</ref>
<ref id="B15">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Qadir</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Wen</surname>
<given-names>C.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Ion-substituted calcium phosphate coatings by physical vapor deposition magnetron sputtering for biomedical applications: A review</article-title>. <source>Acta. Biomater.</source> <volume>89</volume>, <fpage>14</fpage>&#x2013;<lpage>32</lpage>. <pub-id pub-id-type="doi">10.1016/j.actbio.2019.03.006</pub-id>
</citation>
</ref>
<ref id="B16">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Robo</surname>
<given-names>I.</given-names>
</name>
<name>
<surname>Heta</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Papakozma</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Ostreni</surname>
<given-names>V.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Modification of implant surfaces to stimulate mesenchymal cell activation</article-title>. <source>Bull. Natl. Res. Cent.</source> <volume>46</volume>, <fpage>52</fpage>. <pub-id pub-id-type="doi">10.1186/s42269-022-00743-x</pub-id>
</citation>
</ref>
<ref id="B17">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Seyssens</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Eeckhout</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Cosyn</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Immediate implant placement with or without socket grafting: A systematic review and meta&#x2010;analysis</article-title>. <source>Clin. Implant. Dent. Relat. Res.</source> <volume>24</volume>, <fpage>339</fpage>&#x2013;<lpage>351</lpage>. <pub-id pub-id-type="doi">10.1111/cid.13079</pub-id>
</citation>
</ref>
<ref id="B18">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Shi</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Gu</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Qiao</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Lai</surname>
<given-names>H.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Effect of titanium implants with strontium incorporation on bone apposition in animal models: A systematic review and meta-analysis</article-title>. <source>Sci. Rep.</source> <volume>7</volume>, <fpage>15563</fpage>. <pub-id pub-id-type="doi">10.1038/s41598-017-15488-1</pub-id>
</citation>
</ref>
<ref id="B19">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Slagter</surname>
<given-names>K. W.</given-names>
</name>
<name>
<surname>Meijer</surname>
<given-names>H. J. A.</given-names>
</name>
<name>
<surname>Hentenaar</surname>
<given-names>D. F. M.</given-names>
</name>
<name>
<surname>Vissink</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Raghoebar</surname>
<given-names>G. M.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Immediate single-tooth implant placement with simultaneous bone augmentation versus delayed implant placement after alveolar ridge preservation in bony defect sites in the esthetic region: A 5-year randomized controlled trial</article-title>. <source>J. Periodontol.</source> <volume>92</volume>, <fpage>1738</fpage>&#x2013;<lpage>1748</lpage>. <pub-id pub-id-type="doi">10.1002/jper.20-0845</pub-id>
</citation>
</ref>
<ref id="B20">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Stan</surname>
<given-names>G. E.</given-names>
</name>
<name>
<surname>Pasuk</surname>
<given-names>I.</given-names>
</name>
<name>
<surname>Husanu</surname>
<given-names>M. A.</given-names>
</name>
<name>
<surname>Enculescu</surname>
<given-names>I.</given-names>
</name>
<name>
<surname>Pina</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Lemos</surname>
<given-names>A. F.</given-names>
</name>
<etal/>
</person-group> (<year>2011</year>). <article-title>Highly adherent bioactive glass thin films synthetized by magnetron sputtering at low temperature</article-title>. <source>J. Mat. Sci. Mat. Med.</source> <volume>22</volume>, <fpage>2693</fpage>&#x2013;<lpage>2710</lpage>. <pub-id pub-id-type="doi">10.1007/s10856-011-4441-1</pub-id>
</citation>
</ref>
<ref id="B21">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Warheit</surname>
<given-names>D. B.</given-names>
</name>
<name>
<surname>Laurence</surname>
<given-names>B. R.</given-names>
</name>
<name>
<surname>Reed</surname>
<given-names>K. L.</given-names>
</name>
<name>
<surname>Roach</surname>
<given-names>D. H.</given-names>
</name>
<name>
<surname>Reynolds</surname>
<given-names>G. A.</given-names>
</name>
<name>
<surname>Webb</surname>
<given-names>T. R.</given-names>
</name>
</person-group> (<year>2004</year>). <article-title>Comparative pulmonary toxicity assessment of single-wall carbon nanotubes in rats</article-title>. <source>Toxicol. Sci.</source> <volume>77</volume>, <fpage>117</fpage>&#x2013;<lpage>125</lpage>. <pub-id pub-id-type="doi">10.1093/toxsci/kfg228</pub-id>
</citation>
</ref>
<ref id="B22">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Webster</surname>
<given-names>T. J.</given-names>
</name>
<name>
<surname>Ergun</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Doremus</surname>
<given-names>R. H.</given-names>
</name>
<name>
<surname>Siegel</surname>
<given-names>R. W.</given-names>
</name>
<name>
<surname>Bizios</surname>
<given-names>R.</given-names>
</name>
</person-group> (<year>2000</year>). <article-title>Specific proteins mediate enhanced osteoblast adhesion on nanophase ceramics</article-title>. <source>J. Biomed. Mat. Res.</source> <volume>51</volume>, <fpage>475</fpage>&#x2013;<lpage>483</lpage>. <pub-id pub-id-type="doi">10.1002/1097-4636(20000905)51:3&#x3c;475:aid-jbm23&#x3e;3.0.co;2-9</pub-id>
</citation>
</ref>
<ref id="B23">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yeo</surname>
<given-names>I.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Modifications of dental implant surfaces at the micro- and nano-level for enhanced osseointegration</article-title>. <source>Materials</source> <volume>13</volume>, <fpage>89</fpage>. <pub-id pub-id-type="doi">10.3390/ma13010089</pub-id>
</citation>
</ref>
<ref id="B24">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zeman</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Loh</surname>
<given-names>E. W.</given-names>
</name>
<name>
<surname>&#x10c;iern&#xfd;</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>&#x160;er&#xfd;</surname>
<given-names>O.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Penetration, distribution and brain toxicity of titanium nanoparticles in rodents&#x27; body: A review</article-title>. <source>IET. Nanobiotechnol.</source> <volume>12</volume>, <fpage>695</fpage>&#x2013;<lpage>700</lpage>. <pub-id pub-id-type="doi">10.1049/iet-nbt.2017.0109</pub-id>
</citation>
</ref>
</ref-list>
</back>
</article>