<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="review-article">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Mater.</journal-id>
<journal-title>Frontiers in Materials</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Mater.</abbrev-journal-title>
<issn pub-type="epub">2296-8016</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fmats.2015.00047</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Materials</subject>
<subj-group>
<subject>Perspective</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Polymer SU-8-Based Microprobes for Neural Recording and Drug Delivery</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes">
<name><surname>Altuna</surname> <given-names>Ane</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="corresp" rid="cor1">&#x0002A;</xref>
<uri xlink:href="http://frontiersin.org/people/u/140364"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Berganzo</surname> <given-names>Javier</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Fern&#x000E1;ndez</surname> <given-names>Luis J.</given-names></name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<xref ref-type="aff" rid="aff4"><sup>4</sup></xref>
<uri xlink:href="http://frontiersin.org/people/u/167208"/>
</contrib>
</contrib-group>
<aff id="aff1"><sup>1</sup><institution>microLIQUID</institution>, <addr-line>Mondragon</addr-line>, <country>Spain</country></aff>
<aff id="aff2"><sup>2</sup><institution>Microsystems Department, IK4-IKERLAN</institution>, <addr-line>Mondragon</addr-line>, <country>Spain</country></aff>
<aff id="aff3"><sup>3</sup><institution>Centro de Investigaci&#x000F3;n Biom&#x000E9;dica en Red, Biomateriales y Nanomedicina (CIBER-BBN)</institution>, <addr-line>Zaragoza</addr-line>, <country>Spain</country></aff>
<aff id="aff4"><sup>4</sup><institution>Group of Structural Mechanics and Materials Modelling (GEMM), Arag&#x000F3;n Institute of Engineering Research (I3A), Universidad de Zaragoza</institution>, <addr-line>Zaragoza</addr-line>, <country>Spain</country></aff>
<author-notes>
<fn fn-type="edited-by"><p>Edited by: Daniel J. Solis, BioNano Genomics, USA</p></fn>
<fn fn-type="edited-by"><p>Reviewed by: Jose L. Garcia-Cordero, Center for Research and Advanced Studies of the National Polytechnic Institute, Mexico; Jungkyu Jay Kim, Texas Tech University, USA</p></fn>
<corresp content-type="corresp" id="cor1">&#x0002A;Correspondence: Ane Altuna, Goiru 9, 20500, Arrasate, Gipuzkoa, Spain, <email>anealtuna&#x00040;microliquid.com</email></corresp>
<fn fn-type="other" id="fn001"><p>Specialty section: This article was submitted to Translational Materials Science, a section of the journal Frontiers in Materials</p></fn>
</author-notes>
<pub-date pub-type="epub">
<day>18</day>
<month>06</month>
<year>2015</year>
</pub-date>
<pub-date pub-type="collection">
<year>2015</year>
</pub-date>
<volume>2</volume>
<elocation-id>47</elocation-id>
<history>
<date date-type="received">
<day>27</day>
<month>05</month>
<year>2014</year>
</date>
<date date-type="accepted">
<day>30</day>
<month>05</month>
<year>2015</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x000A9; 2015 Altuna, Berganzo and Fern&#x000E1;ndez.</copyright-statement>
<copyright-year>2015</copyright-year>
<copyright-holder>Altuna, Berganzo and Fern&#x000E1;ndez</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license>
</permissions>
<abstract>
<p>This manuscript makes a reflection about SU-8-based microprobes for neural activity recording and drug delivery. By taking advantage of improvements in microfabrication technologies and using polymer SU-8 as the only structural material, we developed several microprobe prototypes aimed to (a) minimize injury in neural tissue, (b) obtain high-quality electrical signals, and (c) deliver drugs at a micrometer precision scale. Dedicated packaging tools have been developed in parallel to fulfill requirements concerning electric and fluidic connections, size and handling. After these advances have been experimentally proven in brain using <italic>in&#x02009;vivo</italic> preparation, the technological concepts developed during consecutive prototypes are discussed in-depth now.</p>
</abstract>
<kwd-group>
<kwd>SU-8 probes</kwd>
<kwd>drug delivery</kwd>
<kwd>neural activity recording</kwd>
<kwd>probe packaging</kwd>
<kwd>microfabrication techniques</kwd>
</kwd-group>
<contract-sponsor id="cn001">Biomedical Application Group at CNM, Barcelona</contract-sponsor>
<contract-sponsor id="cn002">Liset Menendez de la Prida at Instituto Cajal, Madrid</contract-sponsor>
<counts>
<fig-count count="2"/>
<table-count count="0"/>
<equation-count count="0"/>
<ref-count count="31"/>
<page-count count="5"/>
<word-count count="3175"/>
</counts>
</article-meta>
</front>
<body>
<sec id="S1" sec-type="introduction">
<title>Introduction</title>
<p>Microprobe development for neuronal applications has been refined to reach minimal &#x000AD;invasiveness, high reproducibility, and monolithic integration with microelectronics. Reducing the invasive nature of neural probes is a major step while aiming to interfere with neural activity patterns at the cellular level. To this purpose, advances in microfabrication technology have been exploited to integrate high-density sensing sites into a single miniaturized probe for simultaneous discrimination of large neuronal ensembles. Hence, sophisticated fabrication methods have been developed in the microelectronics industry for over half a century. As a result, high reliability and high-volume production levels have been achieved. Furthermore, improvements in communication between microtechnologists and the neuroscientific community were updated in relation with the growth of connection sites, reduction of external signal influence, and autonomy of the device.</p>
<p>In addition to improvements of electronics for neural applications, microfluidic integration gained interest over the last years. In fact, precise and spatiotemporal controlled delivery by microprobes is considered to be one of the most promising directions for delivering pharmacological compounds directly into specific brain regions. From its beginning, silicon technology pioneered the integration of fluidic microchannels into a probe (Chen et al., <xref ref-type="bibr" rid="B7">1997</xref>). Anisotropic silicon etching, boron etch stop, and thermal oxidation/low-pressure chemical vapor deposition sealing were key steps in putting together microelectrodes and fluidic channels for a first time. Changes in the response properties of isolated neurons during drug delivery confirmed the validity of this approach. Since then, efforts have been devised toward precisely control and monitor fluid movements (Lin and Pisano, <xref ref-type="bibr" rid="B16">1999</xref>; McAllister et al., <xref ref-type="bibr" rid="B18">2000</xref>; Rathnasingham et al., <xref ref-type="bibr" rid="B24">2004</xref>; Neeves et al., <xref ref-type="bibr" rid="B21">2006</xref>; Papageorgiou et al., <xref ref-type="bibr" rid="B22">2006</xref>; Foley et al., <xref ref-type="bibr" rid="B11">2009</xref>; Rohatgi et al., <xref ref-type="bibr" rid="B25">2009</xref>; Pongr&#x000E1;cz et al., <xref ref-type="bibr" rid="B23">2013</xref>; Lee et al., <xref ref-type="bibr" rid="B14">2015</xref>). Recently, multi-shank fluidic silicon probes have been developed for neuroscientific applications (Seidl et al., <xref ref-type="bibr" rid="B26">2010</xref>; Frey et al., <xref ref-type="bibr" rid="B12">2011</xref>; John et al., <xref ref-type="bibr" rid="B13">2011</xref>; Spieth et al., <xref ref-type="bibr" rid="B27">2011</xref>). Fluidic channels have been successfully integrated into the silicon 3D configuration via isotropic etching and parylene resealing process.</p>
<p>In parallel, polymer-based microfabrication technology has been developed to deal with invasiveness and brittleness associated with silicon (Subbaroyan et al., <xref ref-type="bibr" rid="B28">2005</xref>; Cheung and Renaud, <xref ref-type="bibr" rid="B8">2006</xref>; Mercanzini et al., <xref ref-type="bibr" rid="B19">2007</xref>, <xref ref-type="bibr" rid="B20">2008</xref>). Parylene technology has already been reported as an option for fluidic applications (Takeuchi et al., <xref ref-type="bibr" rid="B29">2005</xref>). A sacrificial photoresist was defined at specific thickness between two parylene layers and later dissolved to create the cavity. As an alternative to this method, thermal bonding was used (Ziegler et al., <xref ref-type="bibr" rid="B30">2006</xref>). Its main advantages were simplicity, fast production, and the possibility to increase adhesion between the structural layers. Microprobes based on polyimide technology were also developed (Metz et al., <xref ref-type="bibr" rid="B20">2004</xref>). Sputtering and dry etching technique were used to integrate electrodes on the polymer, and lamination technique was implemented to create the channel. It was concluded that this technology offers versatibility for the design of electrodes and channels in terms of size, number, and position. Also, benzocyclobutene (BCB) has been combined with silicon technology to include both, electrodes and fluidics (Lee et al., <xref ref-type="bibr" rid="B15">2004</xref>).</p>
<p>Our group has already exploited polymer SU-8 microfabrication technology in order to integrate multiple electrodes and fluidic channels into a single probe. Over the last years, it has been demonstrated that SU-8 polymer provides optimal properties for neural applications (Lu et al., <xref ref-type="bibr" rid="B17">2006</xref>; Cho et al., <xref ref-type="bibr" rid="B9">2008</xref>; Fern&#x000E1;ndez et al., <xref ref-type="bibr" rid="B10">2009</xref>; Altuna et al., <xref ref-type="bibr" rid="B3">2010</xref>, <xref ref-type="bibr" rid="B4">2012</xref>, <xref ref-type="bibr" rid="B2">2013</xref>). Its high-aspect ratio capability has enabled good dimensional control, and therefore, probes with vertical sidewalls provided a clean insertion into the soft tissue. In addition, high uniformity and adhesion properties ensured the positioning of the metallic tracks on top of the polymer. Recently, planar electrodes were integrated at probe surface and signal recording improved significantly (Altuna et al., <xref ref-type="bibr" rid="B4">2012</xref>). Bonding at low temperature and pressure was first suggested as an optimal technique to create embedded microchannels (Blanco et al., <xref ref-type="bibr" rid="B6">2004</xref>; Agirregabiria et al., <xref ref-type="bibr" rid="B1">2005</xref>; Arroyo et al., <xref ref-type="bibr" rid="B5">2007</xref>; Fern&#x000E1;ndez et al., <xref ref-type="bibr" rid="B10">2009</xref>). Now, even lower temperature combined with higher pressure has been used to avoid internal forces and to guarantee probe planarity. In all cases, the mechanical suitability of SU-8-based probes were experimentally tested for neural application (Lu et al., <xref ref-type="bibr" rid="B17">2006</xref>; Cho et al., <xref ref-type="bibr" rid="B9">2008</xref>; Fern&#x000E1;ndez et al., <xref ref-type="bibr" rid="B10">2009</xref>; Altuna et al., <xref ref-type="bibr" rid="B3">2010</xref>, <xref ref-type="bibr" rid="B4">2012</xref>, <xref ref-type="bibr" rid="B2">2013</xref>). In addition, new achievements regarding probe packaging are addressed in this document. Packaging is known to be a major cost factor in the field of medical microdevices. Therefore, simple, robust, and re-usable housing becomes highly desirable, especially when life-limiting components are used. When electric and fluidic functions are integrated into a single microdevice, all connections have to fit into tight space restriction. Accordingly, our microfluidic SU-8 probes have been displayed every time by a dedicated packaging based on high-resolution 3D printing techniques (Fern&#x000E1;ndez et al., <xref ref-type="bibr" rid="B10">2009</xref>; Altuna et al., <xref ref-type="bibr" rid="B3">2010</xref>, <xref ref-type="bibr" rid="B4">2012</xref>, <xref ref-type="bibr" rid="B2">2013</xref>).</p>
</sec>
<sec id="S2">
<title>Viability Study of SU-8 Microprobes for Neural Applications</title>
<p>Our first SU-8 prototype included novel design and material concepts to allow a flexible microprobe fabrication for a wide range of neural applications (Figure <xref ref-type="fig" rid="F1">1</xref>A). Polymer SU-8 was chosen as an exclusive structural material aimed to integrate miniaturized electrodes and fluidic microchannels. Insertion area was chosen to be considerably larger than typical silicon-based probes during the first stage of development (400&#x02009;&#x003BC;m&#x02009;&#x000D7;&#x02009;220&#x02009;&#x003BC;m) to ensure mechanical stiffness of the SU-8 shank. Six electrodes with a size of 50&#x02009;&#x003BC;m&#x02009;&#x000D7;&#x02009;50&#x02009;&#x003BC;m were placed close to the tip to facilitate recording of neuronal signals close to the delivery radius. Photolithography technique was used to define the pattern of the probe, and metallic layers were coated on top of a thick undeveloped SU-8 layer for the first time by a controlled sputtering process. In addition, SU-8 made microchannels were processed on top by thermocompression based on a recipe developed by Ikerlan/IK4 (Blanco et al., <xref ref-type="bibr" rid="B6">2004</xref>; Agirregabiria et al., <xref ref-type="bibr" rid="B1">2005</xref>; Arroyo et al., <xref ref-type="bibr" rid="B5">2007</xref>). Preliminary electrical characterization verified the sensing capability of the probe and biological tests confirmed clean delivery into the brain (Fern&#x000E1;ndez et al., <xref ref-type="bibr" rid="B10">2009</xref>).</p>
<fig position="float" id="F1">
<label>Figure 1</label>
<caption><p><bold>Evolution of the SU-8 microprobe shown by scanning electron microscopy (SEM) figures: (A)</bold> initial electrode configuration and a fluidic channel with multiple lateral outlets, <bold>(B)</bold> first tetrode version for <italic>in&#x02009;vitro</italic> applications, <bold>(C)</bold> the tetrode at the probe surface level, <bold>(D)</bold> fluidic implementation to the tetrode version, <bold>(E)</bold> the tetrode with three fluidic outlets in the same face of the probe, <bold>(F)</bold> eight electrodes in a row and two fluidic outlets in the same face of the probe. The outlets are indicated with arrows.</p></caption>
<graphic xlink:href="fmats-02-00047-g001.tif"/>
</fig>
</sec>
<sec id="S3">
<title>Microprobe Development: Minimal Tissue Damage and Improved Electrical Recording</title>
<p>Once functional viability of the first prototype was verified, the dimensions of the insertion area were reduced in an order of magnitude to limit injury of the neural tissue. Probe lengths and designs were adapted for <italic>in&#x02009;vitro</italic> experiments and a tetrode configuration was implemented at the tip in order to record activity from small neuronal groups and to discriminate independent neurons (Figure <xref ref-type="fig" rid="F1">1</xref>B). The electrode diameter was set at 20&#x02009;&#x003BC;m, quite comparable to neuron size. In relation with the fabrication procedure, baking conditions and photolithography exposure dose were optimized to gain resolution of such reduced patterns. This design enabled the recording of extracellular action potentials with peak-to-peak amplitudes comparable to conventional tetrode (Altuna et al., <xref ref-type="bibr" rid="B3">2010</xref>). Then, in an effort to improve the recording capability of the tetrode, a revolutionary fabrication sequence was developed (Altuna et al., <xref ref-type="bibr" rid="B4">2012</xref>). The typical gap between the sensing site and tissue was fully eliminated and planar electrodes were located at the probe surface level (Figure <xref ref-type="fig" rid="F1">1</xref>C). In addition, the thickness of the nearest SU-8 layer was reduced to minimize injury at depth brain <italic>in&#x02009;vivo</italic> recordings. This advances positively impacted on recording capability, as tested experimentally in the rat hippocampus <italic>in&#x02009;vivo</italic>. Action potentials emerging from individual neurons with high peak-to-peak amplitudes were measured using SU-8 probes.</p>
<p>At this stage, a novel fabrication procedure was developed to better integrate planar electrodes and well-defined microchannels in reduced probe sizes. Once the technological scope was demonstrated (Figure <xref ref-type="fig" rid="F1">1</xref>D), we moved forward in order to increase specificity in the application field. The position of the outlets was changed from the lateral side of the probe to the top side in order to place the outlets in the same level as the electrodes (Figure <xref ref-type="fig" rid="F1">1</xref>E). Additionally, a linear electrode configuration was developed to facilitate recording from several brain layers simultaneously. In relation to fluidics, two channels with internal dimensions of 40&#x02009;&#x003BC;m&#x02009;&#x000D7;&#x02009;20&#x02009;&#x003BC;m were added. Both channels had independent inlet and outlet ports in order to control drug delivery individually (Figure <xref ref-type="fig" rid="F1">1</xref>F).</p>
</sec>
<sec id="S4">
<title>Development of Packaging Tools</title>
<p>In parallel to the progress of probe design and microfabrication, packaging was adjusted to each probe prototype. The first packaging was aimed to integrate multiple sensing sites and a single fluidic connection (Fern&#x000E1;ndez et al., <xref ref-type="bibr" rid="B10">2009</xref>). A proper fixation of the probe into the capsule and an improved sealing ensured pressure application up to 4&#x02009;bar (Figure <xref ref-type="fig" rid="F2">2</xref>A). Next probe design required exclusively electric connection and to facilitate handling in typical experimental setups available at neuroscience research laboratories, therefore, a printed circuit board (PCB) with 16 electric contacts was developed (Altuna et al., <xref ref-type="bibr" rid="B3">2010</xref>). A conductive adhesive between the microelectrode and electric pad of the PCB enabled a robust connection for electric data transfer (Figure <xref ref-type="fig" rid="F2">2</xref>B). The third design added complexity due to its eight electric and fluidic ports in such a reduced device (Figure <xref ref-type="fig" rid="F2">2</xref>C). With this prototype we recorded for the first time neural ensemble activity in response to local drug delivery at a microscale resolution (Altuna et al., <xref ref-type="bibr" rid="B2">2013</xref>).</p>
<fig position="float" id="F2">
<label>Figure 2</label>
<caption><p><bold>SU-8 probe-packaging designs: (A)</bold> first packaging design with eight electric contacts and a fluidic connection, <bold>(B)</bold> PCB with tetrode connections, and <bold>(C)</bold> novel packaging with multiple electric and fluidic connections.</p></caption>
<graphic xlink:href="fmats-02-00047-g002.tif"/>
</fig>
<p>Specific details of early SU-8 microprobe prototypes (Figures <xref ref-type="fig" rid="F1">1</xref>A&#x02013;D) and their corresponding packaging (Figures <xref ref-type="fig" rid="F2">2</xref>A&#x02013;C) have been already published. Since the last probe and packaging prototype provided us reliable experimental results, both probe and packaging designs are now under a commercialization program by microLIQUID (<uri xlink:href="http://www.microliquid.com">www.microliquid.com</uri>).</p>
</sec>
<sec id="S5">
<title>Discussion and Future</title>
<p>This manuscript summarizes the evolution of our SU-8 microprobe&#x02019;s design and packaging since its beginning up to the present. The first probe prototype was the master key, since it was demonstrated the viability of polymer SU-8 as structural material for neural applications at fine scale. In each consecutive prototype, electrode design was improved for better signal-to-noise ratio and the fluidic configuration evolved to multiple independent microchannels facing the same side of the electrode. Accordingly, our three packaging designs not only conceived to ensure reliable connections but also easy manipulation. Just as technological aspects of the probe and packaging were improved over time, the complexity of the experiments also increased until simultaneous functionality for depth electrical recording and drug delivery in the brain at a scale of few hundreds of micrometers was demonstrated. Future steps will be focused on chronic neural applications aimed to gain better spatiotemporal control of drug delivery and recording during long-term experiments. In this direction, specific packaging tools will be manufactured with the aim to get a compact probe-packaging ensemble.</p>
</sec>
<sec id="S6">
<title>Conflict of Interest Statement</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
</body>
<back>
<ack>
<p>The authors would like to thank the Biomedical Application Group at CNM, Barcelona and the work team of Liset Menendez de la Prida at Instituto Cajal, Madrid.</p>
</ack>
<ref-list>
<title>References</title>
<ref id="B1"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Agirregabiria</surname> <given-names>M.</given-names></name> <name><surname>Blanco</surname> <given-names>F. J.</given-names></name> <name><surname>Berganzo</surname> <given-names>J.</given-names></name> <name><surname>Arroyo</surname> <given-names>M. T.</given-names></name> <name><surname>Fullaondo</surname> <given-names>A.</given-names></name> <name><surname>Mayora</surname> <given-names>K.</given-names></name> <etal/></person-group> (<year>2005</year>). <article-title>Fabrication of SU-8 multilayer microstructures based on successive CMOS compatible adhesive bonding and releasing steps</article-title>. <source>Lab. Chip</source> <volume>5</volume>, <fpage>545</fpage>&#x02013;<lpage>552</lpage>.<pub-id pub-id-type="doi">10.1039/b500519a</pub-id><pub-id pub-id-type="pmid">15856093</pub-id></citation></ref>
<ref id="B2"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Altuna</surname> <given-names>A.</given-names></name> <name><surname>Bellistri</surname> <given-names>E.</given-names></name> <name><surname>Cid</surname> <given-names>E.</given-names></name> <name><surname>Aivar</surname> <given-names>P.</given-names></name> <name><surname>Gal</surname> <given-names>B.</given-names></name> <name><surname>Berganzo</surname> <given-names>J.</given-names></name> <etal/></person-group> (<year>2013</year>). <article-title>SU-8 based microprobes for simultaneous neural depth recording and drug delivery in the brain</article-title>. <source>Lab. Chip</source> <volume>13</volume>, <fpage>1422</fpage>&#x02013;<lpage>1430</lpage>.<pub-id pub-id-type="doi">10.1039/c3lc41364k</pub-id><pub-id pub-id-type="pmid">23407672</pub-id></citation></ref>
<ref id="B3"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Altuna</surname> <given-names>A.</given-names></name> <name><surname>Gabriel</surname> <given-names>G.</given-names></name> <name><surname>De La Prida</surname> <given-names>L. M.</given-names></name> <name><surname>Tijero</surname> <given-names>M.</given-names></name> <name><surname>Guimer&#x000E1;</surname> <given-names>A.</given-names></name> <name><surname>Berganzo</surname> <given-names>J.</given-names></name> <etal/></person-group> (<year>2010</year>). <article-title>SU-8-based microneedles for in&#x02009;vitro neural applications</article-title>. <source>J. Micromech. Microeng.</source> <volume>20</volume>.<pub-id pub-id-type="doi">10.1088/0960-1317/20/6/064014</pub-id></citation></ref>
<ref id="B4"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Altuna</surname> <given-names>A.</given-names></name> <name><surname>Menendez de la Prida</surname> <given-names>L.</given-names></name> <name><surname>Bellistri</surname> <given-names>E.</given-names></name> <name><surname>Gabriel</surname> <given-names>G.</given-names></name> <name><surname>Guimer&#x000E1;</surname> <given-names>A.</given-names></name> <name><surname>Berganzo</surname> <given-names>J.</given-names></name> <etal/></person-group> (<year>2012</year>). <article-title>SU-8 based microprobes with integrated planar electrodes for enhanced neural depth recording</article-title>. <source>Biosens. Bioelectron.</source> <volume>37</volume>, <fpage>1</fpage>&#x02013;<lpage>5</lpage>.<pub-id pub-id-type="doi">10.1016/j.bios.2012.03.039</pub-id><pub-id pub-id-type="pmid">22633740</pub-id></citation></ref>
<ref id="B5"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Arroyo</surname> <given-names>M. T.</given-names></name> <name><surname>Fern&#x000E1;ndez</surname> <given-names>L. J.</given-names></name> <name><surname>Agirregabiria</surname> <given-names>M.</given-names></name> <name><surname>Ib&#x000E3;ez</surname> <given-names>N.</given-names></name> <name><surname>Aurrekoetxea</surname> <given-names>J.</given-names></name> <name><surname>Blanco</surname> <given-names>F. J.</given-names></name></person-group> (<year>2007</year>). <article-title>Novel all-polymer microfluidic devices monolithically integrated within metallic electrodes for SDS-CGE of proteins</article-title>. <source>J. Micromech. Microeng.</source> <volume>17</volume>, <fpage>1289</fpage>&#x02013;<lpage>1298</lpage>.<pub-id pub-id-type="doi">10.1088/0960-1317/17/7/011</pub-id><pub-id pub-id-type="pmid">16977684</pub-id></citation></ref>
<ref id="B6"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Blanco</surname> <given-names>F. J.</given-names></name> <name><surname>Agirregabiria</surname> <given-names>M.</given-names></name> <name><surname>Garcia</surname> <given-names>J.</given-names></name> <name><surname>Berganzo</surname> <given-names>J.</given-names></name> <name><surname>Tijero</surname> <given-names>M.</given-names></name> <name><surname>Arroyo</surname> <given-names>M. T.</given-names></name> <etal/></person-group> (<year>2004</year>). <article-title>Novel three-dimensional embedded SU-8 microchannels fabricated using a low temperature full wafer adhesive bonding</article-title>. <source>J. Micromech. Microeng.</source> <volume>14</volume>, <fpage>1047</fpage>&#x02013;<lpage>1056</lpage>.<pub-id pub-id-type="doi">10.1088/0960-1317/14/7/027</pub-id></citation></ref>
<ref id="B7"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chen</surname> <given-names>J.</given-names></name> <name><surname>Wise</surname> <given-names>K. D.</given-names></name> <name><surname>Hetke</surname> <given-names>J. F.</given-names></name> <name><surname>Bledsoe</surname> <given-names>S. C.</given-names> <suffix>Jr.</suffix></name></person-group> (<year>1997</year>). <article-title>A multichannel neural probe for selective chemical delivery at the cellular level</article-title>. <source>IEEE Trans. Biomed. Eng.</source> <volume>44</volume>, <fpage>760</fpage>&#x02013;<lpage>769</lpage>.<pub-id pub-id-type="doi">10.1109/10.605435</pub-id><pub-id pub-id-type="pmid">9254989</pub-id></citation></ref>
<ref id="B8"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Cheung</surname> <given-names>K. C.</given-names></name> <name><surname>Renaud</surname> <given-names>P.</given-names></name></person-group> (<year>2006</year>). <article-title>BioMEMS for medicine: on-chip cell characterization and implantable microelectrodes</article-title>. <source>Solid State Electron.</source> <volume>50</volume>, <fpage>551</fpage>&#x02013;<lpage>557</lpage>.<pub-id pub-id-type="doi">10.1016/j.sse.2006.03.023</pub-id></citation></ref>
<ref id="B9"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Cho</surname> <given-names>S. H.</given-names></name> <name><surname>Lu</surname> <given-names>H. M.</given-names></name> <name><surname>Cauller</surname> <given-names>L.</given-names></name> <name><surname>Romero-Ortega</surname> <given-names>M. I.</given-names></name> <name><surname>Lee</surname> <given-names>J. B.</given-names></name> <name><surname>Hughes</surname> <given-names>G. A.</given-names></name></person-group> (<year>2008</year>). <article-title>Biocompatible SU-8-based microprobes for recording neural spike signals from regenerated peripheral nerve fibers</article-title>. <source>IEEE Sens. J.</source> <volume>8</volume>, <fpage>1830</fpage>&#x02013;<lpage>1836</lpage>.<pub-id pub-id-type="doi">10.1109/JSEN.2008.2006261</pub-id></citation></ref>
<ref id="B10"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fern&#x000E1;ndez</surname> <given-names>L. J.</given-names></name> <name><surname>Altuna</surname> <given-names>A.</given-names></name> <name><surname>Tijero</surname> <given-names>M.</given-names></name> <name><surname>Gabriel</surname> <given-names>G.</given-names></name> <name><surname>Villa</surname> <given-names>R.</given-names></name> <name><surname>Rodr&#x000ED;guez</surname> <given-names>M. J.</given-names></name> <etal/></person-group> (<year>2009</year>). <article-title>Study of functional viability of SU-8-based microneedles for neural applications</article-title>. <source>J. Micromech. Microeng.</source> <volume>19</volume>.<pub-id pub-id-type="doi">10.1088/0960-1317/19/2/025007</pub-id></citation></ref>
<ref id="B11"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Foley</surname> <given-names>C. P.</given-names></name> <name><surname>Nishimura</surname> <given-names>N.</given-names></name> <name><surname>Neeves</surname> <given-names>K. B.</given-names></name> <name><surname>Schaffer</surname> <given-names>C. B.</given-names></name> <name><surname>Olbricht</surname> <given-names>W. L.</given-names></name></person-group> (<year>2009</year>). <article-title>Flexible microfluidic devices supported by biodegradable insertion scaffolds for convection-enhanced neural drug delivery</article-title>. <source>Biomed. Microdevices</source> <volume>11</volume>, <fpage>915</fpage>&#x02013;<lpage>924</lpage>.<pub-id pub-id-type="doi">10.1007/s10544-009-9308-6</pub-id><pub-id pub-id-type="pmid">19353271</pub-id></citation></ref>
<ref id="B12"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Frey</surname> <given-names>O.</given-names></name> <name><surname>Holtzman</surname> <given-names>T.</given-names></name> <name><surname>McNamara</surname> <given-names>R. M.</given-names></name> <name><surname>Theobald</surname> <given-names>D. E. H.</given-names></name> <name><surname>Van Der Wal</surname> <given-names>P. D.</given-names></name> <name><surname>De Rooij</surname> <given-names>N. F.</given-names></name> <etal/></person-group> (<year>2011</year>). <article-title>Simultaneous neurochemical stimulation and recording using an assembly of biosensor silicon microprobes and SU-8 microinjectors</article-title>. <source>Sens. Actuators B Chem.</source> <volume>154</volume>, <fpage>96</fpage>&#x02013;<lpage>105</lpage>.<pub-id pub-id-type="doi">10.1016/j.snb.2010.01.034</pub-id></citation></ref>
<ref id="B13"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>John</surname> <given-names>J.</given-names></name> <name><surname>Li</surname> <given-names>Y.</given-names></name> <name><surname>Zhang</surname> <given-names>J.</given-names></name> <name><surname>Loeb</surname> <given-names>J. A.</given-names></name> <name><surname>Xu</surname> <given-names>Y.</given-names></name></person-group> (<year>2011</year>). <article-title>Microfabrication of 3D neural probes with combined electrical and chemical interfaces</article-title>. <source>J. Micromech. Microeng.</source> <volume>21</volume>.<pub-id pub-id-type="doi">10.1088/0960-1317/21/10/105011</pub-id></citation></ref>
<ref id="B14"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lee</surname> <given-names>H. J.</given-names></name> <name><surname>Son</surname> <given-names>Y.</given-names></name> <name><surname>Kim</surname> <given-names>J.</given-names></name> <name><surname>Lee</surname> <given-names>C. J.</given-names></name> <name><surname>Yoon</surname> <given-names>E. S.</given-names></name> <name><surname>Cho</surname> <given-names>I. J.</given-names></name></person-group> (<year>2015</year>). <article-title>A multichannel neural probe with embedded microfluidic channels for simultaneous in&#x02009;vivo neural recording and drug delivery</article-title>. <source>Lab. Chip</source> <volume>15</volume>, <fpage>1590</fpage>&#x02013;<lpage>1597</lpage>.<pub-id pub-id-type="doi">10.1039/c4lc01321b</pub-id><pub-id pub-id-type="pmid">25651943</pub-id></citation></ref>
<ref id="B15"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lee</surname> <given-names>K.</given-names></name> <name><surname>He</surname> <given-names>J.</given-names></name> <name><surname>Clement</surname> <given-names>R.</given-names></name> <name><surname>Massia</surname> <given-names>S.</given-names></name> <name><surname>Kim</surname> <given-names>B.</given-names></name></person-group> (<year>2004</year>). <article-title>Biocompatible benzocyclobutene (BCB)-based neural implants with micro-fluidic channel</article-title>. <source>Biosens. Bioelectron.</source> <volume>20</volume>, <fpage>404</fpage>&#x02013;<lpage>407</lpage>.<pub-id pub-id-type="doi">10.1016/j.bios.2004.02.005</pub-id><pub-id pub-id-type="pmid">15308247</pub-id></citation></ref>
<ref id="B16"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lin</surname> <given-names>L.</given-names></name> <name><surname>Pisano</surname> <given-names>A. P.</given-names></name></person-group> (<year>1999</year>). <article-title>Silicon-processed microneedles</article-title>. <source>J. Microelectromech. Syst.</source> <volume>8</volume>, <fpage>78</fpage>&#x02013;<lpage>84</lpage>.<pub-id pub-id-type="doi">10.1109/84.749406</pub-id></citation></ref>
<ref id="B17"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lu</surname> <given-names>H.</given-names></name> <name><surname>Cho</surname> <given-names>S.-H.</given-names></name> <name><surname>Lee</surname> <given-names>J.-B.</given-names></name> <name><surname>Romero-Ortega</surname> <given-names>M.</given-names></name> <name><surname>Cauller</surname> <given-names>L.</given-names></name> <name><surname>Hughes</surname> <given-names>G.</given-names></name></person-group> (<year>2006</year>). &#x0201C;<article-title>SU8-based micro neural probe for enhanced chronic in-vivo recording of spike signals from regenerated axons</article-title>,&#x0201D; in <source>Proceedings of IEEE Sensors, Art. No. 4178557</source>, <fpage>66</fpage>&#x02013;<lpage>69</lpage>.</citation></ref>
<ref id="B18"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>McAllister</surname> <given-names>D. V.</given-names></name> <name><surname>Allen</surname> <given-names>M. G.</given-names></name> <name><surname>Prausnitz</surname> <given-names>M. R.</given-names></name></person-group> (<year>2000</year>). <article-title>Microfabricated microneedles for gene and drug delivery</article-title>. <source>Annu Rev Biomed Eng</source> <volume>2</volume>, <fpage>289</fpage>&#x02013;<lpage>313</lpage>.</citation></ref>
<ref id="B19"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mercanzini</surname> <given-names>A.</given-names></name> <name><surname>Cheung</surname> <given-names>K.</given-names></name> <name><surname>Buhl</surname> <given-names>D. L.</given-names></name> <name><surname>Boers</surname> <given-names>M.</given-names></name> <name><surname>Maillard</surname> <given-names>A.</given-names></name> <name><surname>Colin</surname> <given-names>P.</given-names></name> <etal/></person-group> (<year>2008</year>). <article-title>Demonstration of cortical recording using novel flexible polymer neural probes</article-title>. <source>Sens. Actuators A Phys.</source> <volume>143</volume>, <fpage>90</fpage>&#x02013;<lpage>96</lpage>.<pub-id pub-id-type="doi">10.1016/j.sna.2007.07.027</pub-id></citation></ref>
<ref id="B20"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Metz</surname> <given-names>S.</given-names></name> <name><surname>Bertsch</surname> <given-names>A.</given-names></name> <name><surname>Bertrand</surname> <given-names>D.</given-names></name> <name><surname>Renaud</surname> <given-names>P.</given-names></name></person-group> (<year>2004</year>). <article-title>Flexible polyimide probes with microelectrodes and embedded microfluidic channels for simultaneous drug delivery and multi-channel monitoring of bioelectric activity</article-title>. <source>Biosens. Bioelectron.</source> <volume>19</volume>, <fpage>1309</fpage>&#x02013;<lpage>1318</lpage>.<pub-id pub-id-type="doi">10.1016/j.bios.2003.11.021</pub-id><pub-id pub-id-type="pmid">15046764</pub-id></citation></ref>
<ref id="B21"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Neeves</surname> <given-names>K. B.</given-names></name> <name><surname>Lo</surname> <given-names>C. T.</given-names></name> <name><surname>Foley</surname> <given-names>C. P.</given-names></name> <name><surname>Saltzman</surname> <given-names>W. M.</given-names></name> <name><surname>Olbricht</surname> <given-names>W. L.</given-names></name></person-group> (<year>2006</year>). <article-title>Fabrication and characterization of microfluidic probes for convection enhanced drug delivery</article-title>. <source>J. Control. Release</source> <volume>111</volume>, <fpage>252</fpage>&#x02013;<lpage>262</lpage>.<pub-id pub-id-type="doi">10.1016/j.jconrel.2005.11.018</pub-id><pub-id pub-id-type="pmid">16476500</pub-id></citation></ref>
<ref id="B22"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Papageorgiou</surname> <given-names>D. P.</given-names></name> <name><surname>Shore</surname> <given-names>S. E.</given-names></name> <name><surname>Bledsoe</surname> <given-names>S. C.</given-names> <suffix>Jr.</suffix></name> <name><surname>Wise</surname> <given-names>K. D.</given-names></name></person-group> (<year>2006</year>). <article-title>A shuttered neural probe with on-chip flowmeters for chronic in&#x02009;vivo drug delivery</article-title>. <source>J. Microelectromech. Syst.</source> <volume>15</volume>, <fpage>1025</fpage>&#x02013;<lpage>1033</lpage>.<pub-id pub-id-type="doi">10.1109/JMEMS.2005.863733</pub-id></citation></ref>
<ref id="B23"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pongr&#x000E1;cz</surname> <given-names>A.</given-names></name> <name><surname>Fekete</surname> <given-names>Z.</given-names></name> <name><surname>M&#x000E1;rton</surname> <given-names>G.</given-names></name> <name><surname>B&#x000E9;rces</surname> <given-names>Z.</given-names></name> <name><surname>Ulbert</surname> <given-names>I.</given-names></name> <name><surname>F&#x000FC;rjes</surname> <given-names>P.</given-names></name></person-group> (<year>2013</year>). <article-title>Deep-brain&#x02009;silicon multielectrodes for simultaneous in&#x02009;vivo neural recording and drug delivery</article-title>. <source>Sens. Actuators B Chem.</source> <volume>189</volume>, <fpage>97</fpage>&#x02013;<lpage>105</lpage>.<pub-id pub-id-type="doi">10.1039/c4lc01321b</pub-id><pub-id pub-id-type="pmid">25651943</pub-id></citation></ref>
<ref id="B24"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Rathnasingham</surname> <given-names>R.</given-names></name> <name><surname>Kipke</surname> <given-names>D. R.</given-names></name> <name><surname>Bledsoe</surname> <given-names>S. C.</given-names> <suffix>Jr.</suffix></name> <name><surname>McLaren</surname> <given-names>J. D.</given-names></name></person-group> (<year>2004</year>). <article-title>Characterization of implantable microfabricated fluid delivery devices</article-title>. <source>IEEE Trans. Biomed. Eng.</source> <volume>51</volume>, <fpage>138</fpage>&#x02013;<lpage>145</lpage>.<pub-id pub-id-type="doi">10.1109/TBME.2003.820311</pub-id><pub-id pub-id-type="pmid">14723503</pub-id></citation></ref>
<ref id="B25"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Rohatgi</surname> <given-names>P.</given-names></name> <name><surname>Langhals</surname> <given-names>N. B.</given-names></name> <name><surname>Kipke</surname> <given-names>D. R.</given-names></name> <name><surname>Patil</surname> <given-names>P. G.</given-names></name></person-group> (<year>2009</year>). <article-title>In&#x02009;vivo performance of a microelectrode neural probe with integrated drug delivery laboratory investigation</article-title>. <source>Neurosurg. Focus</source> <volume>27</volume>.<pub-id pub-id-type="doi">10.3171/2009.4.FOCUS0983</pub-id><pub-id pub-id-type="pmid">19569896</pub-id></citation></ref>
<ref id="B26"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Seidl</surname> <given-names>K.</given-names></name> <name><surname>Spieth</surname> <given-names>S.</given-names></name> <name><surname>Herwik</surname> <given-names>S.</given-names></name> <name><surname>Steigert</surname> <given-names>J.</given-names></name> <name><surname>Zengerle</surname> <given-names>R.</given-names></name> <name><surname>Paul</surname> <given-names>O.</given-names></name> <etal/></person-group> (<year>2010</year>). <article-title>In-plane silicon probes for simultaneous neural recording and drug delivery</article-title>. <source>J. Micromech. Microeng.</source> <volume>20</volume>.<pub-id pub-id-type="doi">10.1088/0960-1317/20/10/105006</pub-id></citation></ref>
<ref id="B27"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Spieth</surname> <given-names>S.</given-names></name> <name><surname>Brett</surname> <given-names>O.</given-names></name> <name><surname>Seidl</surname> <given-names>K.</given-names></name> <name><surname>Aarts</surname> <given-names>A. A. A.</given-names></name> <name><surname>Erismis</surname> <given-names>M. A.</given-names></name> <name><surname>Herwik</surname> <given-names>S.</given-names></name> <etal/></person-group> (<year>2011</year>). <article-title>A floating 3D silicon microprobe array for neural drug delivery compatible with electrical recording</article-title>. <source>J. Micromech. Microeng.</source> <volume>21</volume>.<pub-id pub-id-type="doi">10.1088/0960-1317/21/12/125001</pub-id></citation></ref>
<ref id="B28"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Subbaroyan</surname> <given-names>J.</given-names></name> <name><surname>Martin</surname> <given-names>D. C.</given-names></name> <name><surname>Kipke</surname> <given-names>D. R.</given-names></name></person-group> (<year>2005</year>). <article-title>A finite-element model of the mechanical effects of implantable microelectrodes in the cerebral cortex</article-title>. <source>J. Neural Eng.</source> <volume>2</volume>, <fpage>103</fpage>&#x02013;<lpage>113</lpage>.<pub-id pub-id-type="doi">10.1088/1741-2560/2/4/006</pub-id><pub-id pub-id-type="pmid">16317234</pub-id></citation></ref>
<ref id="B29"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Takeuchi</surname> <given-names>S.</given-names></name> <name><surname>Ziegler</surname> <given-names>D.</given-names></name> <name><surname>Yoshida</surname> <given-names>Y.</given-names></name> <name><surname>Mabuchi</surname> <given-names>K.</given-names></name> <name><surname>Suzuki</surname> <given-names>T.</given-names></name></person-group> (<year>2005</year>). <article-title>Parylene flexible neural probes integrated with microfluidic channels</article-title>. <source>Lab. Chip</source> <volume>5</volume>, <fpage>519</fpage>&#x02013;<lpage>523</lpage>.<pub-id pub-id-type="doi">10.1039/b417497f</pub-id><pub-id pub-id-type="pmid">15856088</pub-id></citation></ref>
<ref id="B30"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ziegler</surname> <given-names>D.</given-names></name> <name><surname>Suzuki</surname> <given-names>T.</given-names></name> <name><surname>Takeuchi</surname> <given-names>S.</given-names></name></person-group> (<year>2006</year>). <article-title>Fabrication of flexible neural probes with built-in microfluidic channels by thermal bonding of Parylene</article-title>. <source>J. Microelectromech. Syst.</source> <volume>15</volume>, <fpage>1477</fpage>&#x02013;<lpage>1482</lpage>.<pub-id pub-id-type="doi">10.1109/JMEMS.2006.879681</pub-id></citation></ref>
</ref-list>