<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="research-article" dtd-version="2.3" xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Environ. Sci.</journal-id>
<journal-title>Frontiers in Environmental Science</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Environ. Sci.</abbrev-journal-title>
<issn pub-type="epub">2296-665X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">741343</article-id>
<article-id pub-id-type="doi">10.3389/fenvs.2021.741343</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Environmental Science</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Common Effluent Treatment Plants Monitoring and Process Augmentation Options to Conform Non-potable Reuse</article-title>
<alt-title alt-title-type="left-running-head">Ali et&#x20;al.</alt-title>
<alt-title alt-title-type="right-running-head">CETP Monitoring for Non-Potable Reuse</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Ali</surname>
<given-names>Muntjeer</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="corresp" rid="c001">
<sup>&#x2a;</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1406139/overview"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Almohana</surname>
<given-names>Abdulaziz Ibrahim</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1407732/overview"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Alali</surname>
<given-names>Abdulrhman Fahmi</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1546549/overview"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Kamal</surname>
<given-names>Mohab Amin</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1481016/overview"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Khursheed</surname>
<given-names>Abbas</given-names>
</name>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Khursheed</surname>
<given-names>Anwar</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1411057/overview"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Kazmi</surname>
<given-names>A. A.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/822287/overview"/>
</contrib>
</contrib-group>
<aff id="aff1">
<label>
<sup>1</sup>
</label>Environmental Engineering Group, Civil Engineering Department, Indian Institute of Technology Roorkee (IITR) Uttarakhand (India), <addr-line>Roorkee</addr-line>, <country>India</country>
</aff>
<aff id="aff2">
<label>
<sup>2</sup>
</label>Department of Civil Engineering, College of Engineering, King Saud University, <addr-line>Riyadh</addr-line>, <country>Saudi Arabia</country>
</aff>
<aff id="aff3">
<label>
<sup>3</sup>
</label>Department of Civil Engineering, Z.H. College of Engineering and Technology, AMU, <addr-line>Aligarh</addr-line>, <country>India</country>
</aff>
<aff id="aff4">
<label>
<sup>4</sup>
</label>School of Civil Engineering, Vellore Institute of Technology (VIT), <addr-line>Chennai</addr-line>, <country>India</country>
</aff>
<author-notes>
<fn fn-type="edited-by">
<p>
<bold>Edited by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1251295/overview">Sheena Kumari</ext-link>, Durban University of Technology, South Africa</p>
</fn>
<fn fn-type="edited-by">
<p>
<bold>Reviewed by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/460264/overview">Rakesh Bhutiani</ext-link>, Gurukul Kangri Vishwavidyalaya, India</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1311340/overview">Nataraj Sanna Kotrappanavar</ext-link>, Jain University, India</p>
</fn>
<corresp id="c001">&#x2a;Correspondence: Muntjeer Ali, <email>muntazir.ce@sric.iitr.ac.in</email>
</corresp>
<fn fn-type="other">
<p>This article was submitted to Water and Wastewater Management, a section of the journal Frontiers in Environmental Science</p>
</fn>
</author-notes>
<pub-date pub-type="epub">
<day>10</day>
<month>12</month>
<year>2021</year>
</pub-date>
<pub-date pub-type="collection">
<year>2021</year>
</pub-date>
<volume>9</volume>
<elocation-id>741343</elocation-id>
<history>
<date date-type="received">
<day>14</day>
<month>07</month>
<year>2021</year>
</date>
<date date-type="accepted">
<day>17</day>
<month>11</month>
<year>2021</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2021 Ali, Almohana, Alali, Kamal, Khursheed, Khursheed and Kazmi.</copyright-statement>
<copyright-year>2021</copyright-year>
<copyright-holder>Ali, Almohana, Alali, Kamal, Khursheed, Khursheed and Kazmi</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these&#x20;terms.</p>
</license>
</permissions>
<abstract>
<p>The stringency in effluent discharge and reuse standards has made it extremely expensive to discharge the effluents safely or reuse them. Therefore, existing wastewater treatment plants should be evaluated and improved or augmented. With this aim, five existing common effluent treatment plants (CETPs) in North India were evaluated, including: the State infrastructure Development Corporation Uttrakhand Limited (SIDCUL) Haridwar, which processes 4.5&#xa0;Million Liters per day (MLD); the Industrial Model Township (IMT) Manesar Gurgaon, 55 MLD (comprising two streams of 25 and 30 MLD each); the Lawrence Road Industrial Area (LRIA), Delhi, 12MLD (12MLD LRIA); Mayapuri Industrial Area (MIA), Delhi, 12MLD; and the Integrated Industrial Estate (IIE) SIDCUL Pantnagar, 4.0 MLD. These plants were designed to produce treated effluent for non-potable reuse. Results showed that the integrated efficiency (IE<sub>a</sub>) of all CETPs was 10&#x2013;20% larger than standard integrated efficiency (IE<sub>s</sub>), indicating the suitability of the technology, except for 12MLD at MIA CETP where the IE<sub>a</sub> was 20% lower than IE<sub>s,</sub> due to the absence of any biological unit in the process. Combined post-treatment of secondary effluent by coagulation, Ultrafiltration (UF), followed by ozonation for CETP SIDCUL Haridwar, was also conducted for its non-potable water reuse. This process was able to reduce Biochemical Oxygen Demand (BOD) by 77%, Chemical Oxygen Demand (COD) by 76%, turbidity by 96%, and Total Suspended Solids (TSS) by 100%. All these parameters confirmed the effluent standards for non-potable reuse. The color was reduced to 4.0 from 42.0&#xa0;Pt-Co units by the exposure ozone concentration of 8.3&#xa0;mg/L for up to 4.0&#xa0;min on the treated water from SIDCUL CETP, which reduced the color by 90% and complied with reuse standards. Hence Combined post treatment by coagulation, UF followed Ozonation of secondary treated effluent could be a better option for the potable reuse of treated water in various domestic and industrial applications.</p>
</abstract>
<kwd-group>
<kwd>common effluent treatment plant</kwd>
<kwd>performance evaluation</kwd>
<kwd>coagulation</kwd>
<kwd>ultrafiltration</kwd>
<kwd>ozonation</kwd>
<kwd>non-potable reuse</kwd>
</kwd-group>
</article-meta>
</front>
<body>
<sec id="s1">
<title>Introduction</title>
<p>Globally, approximately 80 countries and 40% of the world&#x2019;s population are facing water scarcity, and the demand for water doubles every 2&#xa0;decades (<xref ref-type="bibr" rid="B1">Aziz et&#x20;al., 2008</xref>). In India, about 500&#xa0;billion cubic meters of fresh water are used annually for industrial activities including about 10&#xa0;billion cubic meters by processing industries, 30&#xa0;million cubic meters for refrigeration purposes, despite restrictions on direct use of freshwater in every category of industry. Various studies have shown that small and medium industries are the major contributor to water pollution. Industries such as Thermal power plants, Pulp and Paper, Textile, Steel, Sugar, Fertilizer, Heavy Engineering, and others that discharge 30,729&#xa0;m<sup>3</sup> of wastewater annually and/or consume 40,012&#xa0;m<sup>3</sup> annually. This amounts to 76.8% conversion of fresh water to wastewater, which ultimately ends up in natural water bodies. This indiscriminate disposal causes water pollution of natural resources and makes them unsafe for future potable reuse, increasing the cost of industries located downstream and higher industrial production costs, which eventually burden consumers.</p>
<p>Current wastewater treatment approaches are becoming increasingly expensive, as effluent discharge standards become more stringent day by day. However, technological advancement now makes it possible to treat wastewater for a variety of industrial reuse (<xref ref-type="bibr" rid="B19">Visvanathan and Asano, 2014</xref>). Small to medium scale industries often do not comply with these stringent reuse standards due to well-documented reasons, such as a lack of footprint assessment, specialized manpower, limited financial assets/funds, and high capital cost (<xref ref-type="bibr" rid="B16">Pathe et&#x20;al., 2004</xref>). These problems could be reduced by the collective treatment of effluents from a large number of small-scale facilities at a single site where the effluent from each undergoes treatment (<xref ref-type="bibr" rid="B14">Padalkar, Kaur, and Kumar, 2016</xref>). This helps in terms of land conservation, better treatment at one location, easy operation and maintenance, shared expenses and is encouraged by regulating state agencies (<xref ref-type="bibr" rid="B20">Vyas et&#x20;al., 2011</xref>).</p>
<p>The collective treatment of effluent at a CETPs is a suitable and recommended solution for small/medium scale industries. CETPs typically consist of the combined arrangements of separate unit processes, supporting the performance of other unit processes during wastewater treatment. The wastewater characteristics at the inlet and the anticipated quality of treated water determine the quantum of treatment required and hence the size and complex design of the plant (<xref ref-type="bibr" rid="B10">Jern, 2006</xref>; <xref ref-type="bibr" rid="B7">Ghumra D.P et&#x20;al., 2021</xref>). Preliminary and primary treatment units are generally size-based separation units, which are required for a basic clean-up of the industrial effluents and hence followed by secondary and tertiary treatment methods. The primary treatment units can remove the COD and TSS over a range of 10&#x2013;40% depending on the content of the effluent and applied technology. The secondary treatment processes reduce the COD, BOD, and TSS up to 85&#x2013;95% for the industrial effluent. Tertiary units are typically required for final polishing the effluent by elimination of toxic and hazardous contaminants to the desired level. It has been reported that up to 99% of contaminant removal can be successfully obtained by the implementation of tertiary units (<xref ref-type="bibr" rid="B17">Ranade and Bhandari, 2014</xref>). The performance of CETPs in India until now has been unsatisfactory because of a wide variety of effluents, damage to treatment units, and clogging of the pumping system, etc. The presence of organic contaminants and pharmaceuticals is likely to affect the efficiency of CETPs (<xref ref-type="bibr" rid="B15">Padalkar and Kumar, 2019</xref>). As a result, secondary or tertiary treated effluent from CETPs has progressively been used to produce alternative water resources due to their accessibility (<xref ref-type="bibr" rid="B12">Michael-Kordatou et&#x20;al., 2015</xref>). Namibia, California (United&#x20;States), and Singapore have employed these efforts to overcome water scarcity and potable reuse (<xref ref-type="bibr" rid="B9">Harris-Lovett et&#x20;al., 2015</xref>; <xref ref-type="bibr" rid="B21">Warsinger et&#x20;al., 2018</xref>). Non-potable reuse of water from the effluent of sewage treatment plants (STP) is an economical and preferred way of saving water and has become a common practice. A number of studies have examined the reuse of greywater from domestic sewage (<xref ref-type="bibr" rid="B8">Gr&#xfc;ttner et&#x20;al., 1994</xref>). Since, CETP treats water both from domestic and industrial discharge, achieving standards for non-potable reuse from the effluent of a CETP is a challenging task because it is a huge capital cost intensive activity and there are stringent effluent reuse standards. In India, there are approximately 193 CETPs, out of which 45 units are operated in North India (14 in Haryana, 1 in Himachal Pradesh, 1 in Jammu and Kashmir, 13 in National Capital Territory (NCT), Delhi, 4 in Punjab, 8 in Uttar Pradesh and 4 in Uttarakhand) (<xref ref-type="bibr" rid="B2">CPCB, 2018</xref>). Most of the CETPs were designed and installed for reuse of treated water for non-potable purposes in industrial or other activities. The installed CETPs are equipped with primary to secondary biological treatment followed by tertiary treatment including pressure sand/activated carbon filtration. However, the CETPs may still require further evaluation to remove trace organics, heavy metals, and color (<xref ref-type="bibr" rid="B6">Gerrity et&#x20;al., 2013</xref>). Regulating agencies have observed that CETPs do not discharge satisfactory effluent for reuse, because of technological/process design limitations and the massive fluctuation in the organic load of primary treated effluent from industries, which hampers the biological activity of aeration tanks due to varied pH and other operational parameters.</p>
<p>This study (funded by GIZ Germany and Gurugram Metropolitan Development Authority (GMDA), India) aimed at examining the status and performance evaluation of existing CETPs in northern India and undertook a lab-scale study based on combined coagulation, ultrafiltration, and ozonation of the secondary effluent from CETPs to produce water for non-potable reuse <bold>(</bold>
<xref ref-type="table" rid="T1">Table&#x20;1</xref>
<bold>).</bold> <xref ref-type="fig" rid="F1">Figure&#x20;1</xref> includes a detailed flow chart of the methodology adopted for this&#x20;study.</p>
<table-wrap id="T1" position="float">
<label>TABLE 1</label>
<caption>
<p>Effluent Reuse recommendations (CPHEEO, 2013). Standards for treated wastewater reclamation and reuse, set by the Government of India regulating agency.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th rowspan="4" align="left">S/No</th>
<th rowspan="4" align="center">Parameters</th>
<th rowspan="4" align="center">Toilet flushing</th>
<th rowspan="4" align="center">Fire Protection</th>
<th rowspan="4" align="center">Vehicle Exterior Washing</th>
<th rowspan="4" align="center">Non- Contact Impoundment</th>
<th colspan="4" align="center">Landscaping, Horticulture and Agriculture</th>
</tr>
<tr>
<th rowspan="3" align="center">Horticulture, Golf Course</th>
<th colspan="3" align="center">Crops</th>
</tr>
<tr>
<th rowspan="2" align="center">Non-Edible Crops</th>
<th colspan="2" align="center">Food Crops</th>
</tr>
<tr>
<th align="center">Raw</th>
<th align="center">Cooked</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">1</td>
<td align="left">Turbidity (NTU)</td>
<td align="center">&#x3c;2</td>
<td align="center">&#x3c;2</td>
<td align="center">&#x3c;2</td>
<td align="center">&#x3c;2</td>
<td align="center">&#x3c;2</td>
<td align="center">AA</td>
<td align="center">&#x3c;2</td>
<td align="center">AA</td>
</tr>
<tr>
<td align="left">2</td>
<td align="left">SS (mg/L)</td>
<td align="center">AA</td>
<td align="center">AA</td>
<td align="center">AA</td>
<td align="center">AA</td>
<td align="center">AA</td>
<td align="center">30</td>
<td align="center">AA</td>
<td align="center">30</td>
</tr>
<tr>
<td align="left">3</td>
<td align="left">TDS (mg/L)</td>
<td colspan="8" align="center">2,100</td>
</tr>
<tr>
<td align="left">4</td>
<td align="left">pH</td>
<td colspan="8" align="center">6.5&#x2013;8.3</td>
</tr>
<tr>
<td align="left">5</td>
<td align="left">Temp <sup>0</sup>C</td>
<td colspan="8" align="center">Ambient</td>
</tr>
<tr>
<td align="left">6</td>
<td align="left">Oil and Grease (mg/L)</td>
<td align="center">10</td>
<td align="center">Nil</td>
<td align="center">Nil</td>
<td align="center">Nil</td>
<td align="center">10</td>
<td align="center">10</td>
<td align="center">Nil</td>
<td align="center">Nil</td>
</tr>
<tr>
<td align="left">7</td>
<td align="left">Residual Chlorine (mg/L)</td>
<td align="center">1</td>
<td align="center">1</td>
<td align="center">1</td>
<td align="center">0.5</td>
<td align="center">1</td>
<td align="center">Nil</td>
<td align="center">Nil</td>
<td align="center">Nil</td>
</tr>
<tr>
<td align="left">8</td>
<td align="left">TKN as N (mg/L)</td>
<td align="center">10</td>
<td align="center">10</td>
<td align="center">10</td>
<td align="center">10</td>
<td align="center">10</td>
<td align="center">10</td>
<td align="center">10</td>
<td align="center">10</td>
</tr>
<tr>
<td align="left">9</td>
<td align="left">BOD (mg/L)</td>
<td align="center">10</td>
<td align="center">10</td>
<td align="center">10</td>
<td align="center">10</td>
<td align="center">10</td>
<td align="center">20</td>
<td align="center">10</td>
<td align="center">20</td>
</tr>
<tr>
<td align="left">10</td>
<td align="left">COD (mg/L)</td>
<td align="center">AA</td>
<td align="center">AA</td>
<td align="center">AA</td>
<td align="center">AA</td>
<td align="center">AA</td>
<td align="center">30</td>
<td align="center">AA</td>
<td align="center">30</td>
</tr>
<tr>
<td align="left">11</td>
<td align="left">PO<sub>4</sub> as P (mg/L)</td>
<td align="center">1</td>
<td align="center">1</td>
<td align="center">1</td>
<td align="center">1</td>
<td align="center">2</td>
<td align="center">5</td>
<td align="center">2</td>
<td align="center">5</td>
</tr>
<tr>
<td align="left">12</td>
<td align="left">NO<sub>3</sub>- N (mg/L)</td>
<td align="center">20</td>
<td align="center">10</td>
<td align="center">10</td>
<td align="center">5</td>
<td align="center">10</td>
<td align="center">10</td>
<td align="center">10</td>
<td align="center">10</td>
</tr>
<tr>
<td align="left">13</td>
<td align="left">Fecal Coliform MPN/100&#xa0;ml</td>
<td align="center">Nil</td>
<td align="center">Nil</td>
<td align="center">Nil</td>
<td align="center">Nil</td>
<td align="center">Nil</td>
<td align="center">230</td>
<td align="center">Nil</td>
<td align="center">230</td>
</tr>
<tr>
<td align="left">14</td>
<td align="left">Color</td>
<td align="center">Colorless</td>
<td align="center">Colorless</td>
<td align="center">Colorless</td>
<td align="center">Colorless</td>
<td align="center">Colorless</td>
<td align="center">Colorless</td>
<td align="center">Colorless</td>
<td align="center">Colorless</td>
</tr>
<tr>
<td align="left">15</td>
<td align="left">Odor</td>
<td colspan="8" align="center">Aesthetic which means not septic and no foul odor</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn>
<p>&#x27a2; AA-as, arising when other parameters are satisfied.</p>
</fn>
<fn>
<p>&#x27a2; CPHEEO, India (Central Public health and Environmental Engineering Organization, India).</p>
</fn>
</table-wrap-foot>
</table-wrap>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption>
<p>Detailed flow showing the adopted methodology for the Monitoring of five CETPS and process augmentation options to conform non-potable reuse.</p>
</caption>
<graphic xlink:href="fenvs-09-741343-g001.tif"/>
</fig>
</sec>
<sec sec-type="materials|methods" id="s2">
<title>Materials and Methods</title>
<sec id="s2-1">
<title>Status of Common Effluent Treatment Plants</title>
<p>The current status of CETPs is given in <xref ref-type="table" rid="T2">Table&#x20;2</xref>. The 4.5 MLD CETP at IIE SIDCUL Haridwar, was operating at 100% capacity. It was upgraded and inserted the MBBR process by removing Physico-chemical treatment due to a variety of contributing industries, its unregulated discharge, inconsistent and regular increase in the concentration of COD, BOD, TSS, Nitrogen, heavy metals, and other pollutants in the influent. It was commissioned in 2008, and the treated effluent was discharged in the Sukhi river, which finally merges with the Ganga River. CETP at IMT Manesar was designed for 55 MLD and operates at 45 MLD (80% capacity). Since it receives wastewater from two equally divided areas it consisted of two streams of 25 and 35 MLD. Both streams have identical treatment processes (physical-chemical &#x2b; Biological treatment and filtration). Between 10&#x2013;15% of the treated effluent is reused in horticulture and gardening, while the rest is discharged to the Yamuna River. The CETPs at LRIA and MIA were both designed for 12 MLD and commissioned in 2004 and 2003, respectively. Both the CETPs operate at a very low capacity of 1.5 and 3.5 MLD due to the changes adopted by the industries in their manufacturing process. CETP at IIE Pantnagar was designed for 4 MLD and operates under capacity, at 2.1 MLD. The treatment scheme of this CETP includes physic-chemical and Biological &#x2b; rapid sand and carbon filtration. The treated effluent is discharged to the Ganga river. All the CETPs in this study are located in a zone of 200&#x2013;400&#xa0;km in Northern India, where the climate, infrastructural, socio-economic, and political conditions are largely similar.</p>
<table-wrap id="T2" position="float">
<label>TABLE 2</label>
<caption>
<p>Status of studied CETPs. Status report of 5 CETPs in three North Indian states, including design capacity and utilization, treatment scheme, disposal point, capital cost, O and M cost, and commissioning&#x20;date.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="left">Parameters</th>
<th align="center">CETP, IIE SIDCUL, Haridwar</th>
<th align="center">CETP, IMT Manesar, Gurgaon</th>
<th align="center">CETP LRIA, Delhi</th>
<th align="center">CETP, MIA Delhi</th>
<th align="center">CETP, IIE Pantnagar</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">Designed Capacity</td>
<td align="center">4.5 MLD</td>
<td align="center">55 MLD</td>
<td align="center">12 MLD</td>
<td align="center">12 MLD</td>
<td align="center">4 MLD</td>
</tr>
<tr>
<td align="left">Present Operating Capacity</td>
<td align="center">4.5 MLD</td>
<td align="center">45 MLD</td>
<td align="center">1.5 MLD</td>
<td align="center">3.5 MLD</td>
<td align="center">2.1 MLD</td>
</tr>
<tr>
<td align="left">Capital Cost (US Dollar)</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="center">125,0186.00</td>
<td align="center">1,490,653.00</td>
<td align="center">NA</td>
</tr>
<tr>
<td align="left">Annual O&#x26;M Cost (US Dollar)</td>
<td align="center">NA</td>
<td align="center">1,600,000.00</td>
<td align="center">1,600,000.00</td>
<td align="center">NA</td>
<td align="center">NA</td>
</tr>
<tr>
<td align="left">Date of Commissioning</td>
<td align="center">2008</td>
<td align="center">2016</td>
<td align="center">2004</td>
<td align="center">2003</td>
<td align="center">2008</td>
</tr>
<tr>
<td align="left">Sludge Generation (MT/Year)</td>
<td align="center">NA</td>
<td align="center">1,080</td>
<td align="center">500</td>
<td align="center">440</td>
<td align="center">NA</td>
</tr>
<tr>
<td align="left">Effluent Disposal</td>
<td align="center">Sukhi River leading to Ganga River</td>
<td align="center">10&#x2013;15% reuse &#x2b; Yamuna River</td>
<td align="center">Yamuna River</td>
<td align="center">Yamuna River</td>
<td align="center">Ganga River</td>
</tr>
<tr>
<td align="left">Treatment Technology</td>
<td align="center">MBBR &#x2b; Activated Sludge Process &#x2b; Filtration</td>
<td align="center">Both streams (25 &#x2b; 30 MLD) Physico-chemical &#x2b; Biological &#x2b; Filtration</td>
<td align="center">Design for Physico-chemical treatment but modified for Partially Biological in Equalization tank followed by settling</td>
<td align="center">Chemical Precipitation &#x2b; Filtration</td>
<td align="center">Physico-chemical &#x2b; Biological &#x2b; Filtration</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
<sec id="s2-2">
<title>Detailed Description of Common Effluent Treatment Plants</title>
<sec id="s2-2-1">
<title>Treatment Scheme of 4.5 Million Liters Per Day Common Effluent Treatment Plants, Industrial Estate State Infrastructure Development Corporation Uttrakhand Limited, Haridwar</title>
<p>This CETP operates on a fully biological process, without any chemical addition. The influent flows through a rapid mixing and flocculation tank. First stage tube settlers then act as pre-settling tanks. The CETP scheme comprises one Raw Effluent Pump House (REPH), having course screen at upstream and fine screen downstream, one oil and grease trap unit, two equalization tanks, two pre-settling tanks (PSTs), an MBBR tank, aeration tank, secondary clarifier, Pressure Sand Filter (PSF), and Activated Carbon Filter (ACF). The schematic flow diagram of CETP is depicted in <xref ref-type="fig" rid="F2">Figure&#x20;2</xref>.</p>
<fig id="F2" position="float">
<label>FIGURE 2</label>
<caption>
<p>Schematic floe diagram of 4.5 MLD CETP IIE SIDCUL, Haridwar. Physico-chemical &#x2b; MBBR base bilogical scheme (EQT - Equalization tanks).</p>
</caption>
<graphic xlink:href="fenvs-09-741343-g002.tif"/>
</fig>
</sec>
<sec id="s2-2-2">
<title>Treatment Scheme of Common Effluent Treatment Plants 55 Million Liters Per Day at Industrial Model Township Manesar, Gurgaon</title>
<p>The integrated CETPs (25 MLD and 30 MLD) treatment system involved raw effluent collection followed by preliminary treatment (Screening, Grit Removal and, Equalization), Physico-chemical treatment (Clariflocculator for 25 MLD, and separate flocculators and clarifiers for 30 MLD), secondary biological treatment (Extended Aeration), and tertiary treatment by Dual Media Filtration (DMF) (<xref ref-type="fig" rid="F3">Figure&#x20;3</xref>). Primary and secondary sludge generated by Physico-chemical and biological treatment is handled together in a gravity thickener and belt press. The dewatered sludge is disposed of in a hazardous waste disposal&#x20;site.</p>
<fig id="F3" position="float">
<label>FIGURE 3</label>
<caption>
<p>Schematic flow diagram of Integrated CETP (25 MLD and 30 MLD) in Manesar Gurgon. Physico-chemical &#x2b; ASP base biological schemes (EQT - Equalization tanks, DMF - Dual Media Filter).</p>
</caption>
<graphic xlink:href="fenvs-09-741343-g003.tif"/>
</fig>
</sec>
<sec id="s2-2-3">
<title>Treatment Scheme of Common Effluent Treatment Plants 12&#xa0;Million Liters Per Day Lawrence Road, Delhi</title>
<p>This CETP was designed for a capacity of 12 MLD of industrial effluent but the flow was 2.5 MLD during the sampling period. At the time of the planning and design of the CETP in early 2000, the wastewater (primarily from a mix of several micro-, small- and medium-scale electroplating and other similar industrial units) was expected to carry higher levels of heavy metals, while its organic load was estimated to be very low, i.e.,&#x20;the BOD was estimated to be 89&#xa0;mg/L. Given the expected nature of the wastewater, the treatment scheme comprised a series of Physico-chemical unit operations and did not include any biological unit process (<xref ref-type="fig" rid="F4">Figure&#x20;4</xref>).</p>
<fig id="F4" position="float">
<label>FIGURE 4</label>
<caption>
<p>The Upgraded Process flow diagram of LRIA CETP. Physico-chemical &#x2b; Enzyme base treatment schemes (EQT - Equalization tank).</p>
</caption>
<graphic xlink:href="fenvs-09-741343-g004.tif"/>
</fig>
<p>As the CETP does not have a biological unit process for the removal of organics, i.e.,&#x20;reduction of BOD and ammonical nitrogen, etc., the operator adopted the practice of dosing commercially available bioculture. Dosage was reported to be 280&#xa0;gm/MLD. To enhance the efficiency of the biological treatment, sludge recirculation an extent of 40% was being practiced.</p>
</sec>
<sec id="s2-2-4">
<title>Treatment Scheme of Common Effluent Treatment Plants 12&#xa0;Million Liters Per Day Mayapuri, Delhi</title>
<p>Similar to the 12 MLD CETP at LRIA in Delhi, this treatment scheme lacks any biological unit process. Interestingly, the scheme consisted of pre-chlorination, which appeared to be not very relevant for an industrial wastewater treatment&#x20;plant.</p>
<p>In addition, it was envisioned that this plant would reuse the treated effluent for horticulture purposes, possibly, and accordingly, the original scheme also included a tertiary treatment stage, which comprised a combination of dual media filters and activated carbon filters. The schematic process flow diagram is presented in <xref ref-type="fig" rid="F5">Figure&#x20;5</xref>.</p>
<fig id="F5" position="float">
<label>FIGURE 5</label>
<caption>
<p>The Process flow diagram for MIA CEPT. Physico-chemical scheme (EQT - Equalization tanks, DMF - Dual Media Filter, ACF - Activated Carbon Filter).</p>
</caption>
<graphic xlink:href="fenvs-09-741343-g005.tif"/>
</fig>
</sec>
<sec id="s2-2-5">
<title>Treatment Scheme of 4&#xa0;Million Liters Per Day Common Effluent Treatment Plants Pantnagar</title>
<p>CETP at IIE SIDCUL Pantnagar is designed as Physico-chemical, followed by biological treatment and filtration. The CETP scheme comprised one Raw Effluent Pump chamber then mechanical bar screen and manual bar screens, one raw effluent sump, grit chamber, an oil and grease chamber, one equalization tank, flash mixer, Clariflocculator, pH correction tank, aeration tank, secondary clarifier, two pressure sand filters, and a treated water tank. Chemical Sludge from the Clariflocculator was transferred to a sludge storage tank followed by sludge drying beds. Biological sludge from the secondary clarifier was then transferred to sludge thickener followed by sludge drying beds. Some fraction of biological sludge is transferred as return sludge to the aeration tank to maintain optimal MLSS (3,000&#x2013;4,000&#xa0;mg/L) for biological activity. The process flow diagram of 4.0 MLD CETP IIE SIDCUL Pantnagar is given in <xref ref-type="fig" rid="F6">Figure&#x20;6</xref>.</p>
<fig id="F6" position="float">
<label>FIGURE 6</label>
<caption>
<p>The Process flow diagram 4.0 MLD CEPT IIE Pantnagar SIDCUL. Physico-chemical &#x2b; ASP base biological scheme (EQT - Equalization tanks, ACF - Activated Carbon Filter, PCF - Pressure Sand Filter).</p>
</caption>
<graphic xlink:href="fenvs-09-741343-g006.tif"/>
</fig>
</sec>
</sec>
<sec id="s2-3">
<title>Sampling and Analytical Methods</title>
<p>Grab samples were collected from the operational units of each CETPs (two sampling for 4.5MLD CETP at SIDCUL Haridwar during March-April 2018, two sampling for 4.0 MLD CETP at IIE SIDCUL Pantnagar during Dec-Jan 2020, two sampling for 55.0 MLD CETP at IMT Manesar during June-July 2018 and two samplings for 12.0 MLD CETP at LRIA &#x26;MIA Delhi during April-July 2017). The performance evaluation included samples for physicochemical parameters such as pH, turbidity, biochemical oxygen demand (BOD), chemical oxygen demand (COD), total suspended solids (TSS), oil and grease, ammonia nitrogen (NH<sub>3</sub>-N), nitrate-nitrogen (NO<sub>3</sub>-N), Total Kjeldahl Nitrogen (TKN), ortho phosphate (PO<sub>4</sub>
<sup>3&#x2212;</sup>P), Total Phosphorus (TP), chloride (Cl<sup>&#x2212;</sup>), sulfate (SO<sub>4</sub>
<sup>&#x2212;2</sup>), Fluoride (F<sup>&#x2212;</sup>), Sulphide (S<sup>&#x2212;2</sup>). These were collected in 1&#xa0;L plastic bottles from the various sampling points namely, the influent (after equalization tank), the effluent of each biological reactor, each clarifier, the filter, and the final treated effluent (after chlorination). Waste sludge samples from the clarifiers were also taken. For the determination of heavy metals, samples were collected in 500&#xa0;ml glass bottles and preserved by adding conc. HCl to reduce the pH to 2. All the samples were transported to the laboratory, preserved at 4&#xb0;C, and analyzed according to Standard Methods (APHA, AWWA, WEF., 2012) (<xref ref-type="bibr" rid="B8">Rice et al., 2012</xref>). Online parameters such as Dissolve oxygen (DO), pH, Sludge Volume Index (SVI), and Specific Oxygen Uptake Rate (SOUR) were performed and recorded at the CETPs. The data were analyzed as per selected objectives.</p>
<sec id="s2-3-1">
<title>Experimental Setup for the Treatment of Secondary Effluent by Combined Coagulation Followed by Ultrafiltration and Ozonation</title>
<p>Parameters such as COD, BOD, TSS, turbidity, and Color did not conform to the non-potable reuse guidelines of CETPs effluent but satisfied Indian Effluent Discharge Standards (Central Public Health and Environmental Engineering Organisation <xref ref-type="bibr" rid="B5">CPHEEO, 2013</xref>). Hence, the secondary treated effluent of CETP SIDCUL Haridwar was examined for combined coagulation followed by UF (ultrafiltration) process to reduce BOD, COD, TSS, and turbidity followed by ozonation.</p>
<p>A combination of coagulation followed by UF and Ozonation setup was installed in the laboratory. secondary treated effluent was first treated through the coagulation-flocculation process by optimal dosing of Alum and Polyelectrolyte (100 and 0.8&#xa0;mg/L respectively) in Jar test followed by UF and Ozonation.</p>
<p>The ultrafiltration hollow fiber modules are extruded in an in-house extrusion machine. The molecular weight of Polysulfone (PS) made membranes was 70 amu. The inner and outer diameter of hollow fibers was 0.7 and 1.3&#xa0;mm respectively. The length of each fiber was 16&#xa0;cm. A total of 80 numbers of such fibers are packed in a &#xbd;&#x201d; internal diameter PVC pipe. Thus, the effective membrane surface area of this cartridge was 280&#xa0;cm<sup>2</sup>. The Molecular Weight Cut Off (MWCO) of the module was 44&#xa0;kDa, and the pore size was 6.46&#xa0;nm.</p>
<p>The UF treatment was carried out at different pressure gradients of 10, 15, 20, and 25 PSI, which corresponded to the effluent flow rate of 2.3, 2.45, 2.85, and 3.5&#xa0;L/h.</p>
</sec>
<sec id="s2-3-2">
<title>Ozonation of Effluent From Ultrafiltration</title>
<p>The ozone doze experiments were carried out using a 1,000&#xa0;ml Pyrex glass reactor designed to provide good contact between the liquid and gas phases. An Indoz model ozone generator was used for generating the ozone needed for the reaction. The ozone produced by using oxygen with a purity of 99.5% was bubbled into a reactor through a diffuser. The experiments with ozone were carried out at room temperature by 1,000&#xa0;ml of DI (Deionized) water taken in the reactor. The pH of the DI water was reduced to two using 0.1&#xa0;M Hydrochloric acid (HCl). The ozone dose was bubbled into DI water using an Ozone Generator and the absorbance was recorded at 254&#xa0;nm using a spectrophotometer at 1&#xa0;min interval&#x20;time.</p>
<p>Treated effluent from UF was subjected to ozonation with different ozone concertation at 1&#xa0;min time intervals. The color (Co-Pt unit) of the effluent from each Ozone treated sample was measured in an Ultra-violet (UV)-Visible spectrophotometer.</p>
</sec>
</sec>
</sec>
<sec sec-type="results|discussion" id="s3">
<title>Results and Discussions</title>
<p>The results and subsequent discussion describe the results after the tertiary treatment of secondary effluent by combined coagulation. This was followed by UF and Ozonation augmentation processes, which were used to make reclaimed water fit for&#x20;reuse.</p>
<sec id="s3-1">
<title>Hydraulic Retention Time</title>
<p>The CETPs used in the present study operated at different Hydraulic retention times (HRTs) due to the different wastewater treatment units. For the 4.5 MLD SIDCUL CETP at Haridwar, the combined calculated HRT of all the units was 29&#xa0;h (16.5&#xa0;h for equalization tank, 2.58&#xa0;h for primary treatment, 2.69&#xa0;h for MBBR tank, 6.46&#xa0;h for secondary clarifier, 0.3&#xa0;h for PSF and ACF). For the 55 MLD IMT CETP at Manesar, the total HRT for the first Stream (25 MLD) was 25.2&#xa0;h (0.5&#xa0;h for preliminary treatment, 2.6&#xa0;h for equalization tank, 3.7&#xa0;h for primary treatment, 8.6&#xa0;h for the aeration tank, 5&#xa0;h for secondary clarifier, 1&#xa0;h for the Dual media filter, 3.8&#xa0;h for chlorination tank) and for its Second Stream (30 MLD) was 15&#xa0;h (1&#xa0;h for preliminary treatment, 2.7&#xa0;h for equalization tank, 1.5&#xa0;h for primary treatment, 5.8&#xa0;h for aeration tank, 3.3&#xa0;h for secondary clarifier, 0.4&#xa0;h for Dual media filter, 0.36&#xa0;h for chlorination tank. For CETP 12 MLD LRIA Delhi, the total HRT was 9.3&#xa0;h (0.06&#xa0;h&#xa0;min for preliminary treatment, 8&#xa0;h for equalization tank, 0.5&#xa0;h pre-chlorination, 0.16&#xa0;h Flocculation tank, 0.25&#xa0;h in Tube settlers, 0.3&#xa0;h Post chlorination). For CETP 12 MLD MIA Delhi, the total HRT was 11&#xa0;h (0.15&#xa0;h for preliminary treatment, 8&#xa0;h for equalization tank, 0.5&#xa0;h pre-chlorination, 0.25&#xa0;h Tube settlers, 0.5&#xa0;h clarified effluent sump, 0.16&#xa0;h Multimedia filters, 0.16&#xa0;min for ACF, 1&#xa0;h Chlorination.) and for 4.0 MLD CETP Pantnagar, the total calculated HRT was 29.50&#xa0;h (20&#xa0;h for oil and grease, the grit chamber, and equalization tank, 3.0&#xa0;h for primary treatment 6.5&#xa0;h for secondary clarifier, 0.3&#xa0;h for&#x20;PSF).</p>
</sec>
<sec id="s3-2">
<title>Operational Control Parameters</title>
<p>SVI was measured to assess the sludge quality. SVI &#x3c;120&#xa0;ml/g was designated good quality while sludge bulking was represented by SVI&#x3e;150&#xa0;ml/g. If the settling happened too quickly, as seen in longer sludge age, there may have been pin floc or high turbidity in the supernatant. Mixed Liquor Suspended Solids (MLSS) and Mixed Liquor Suspended Volatile Solids (MLVSS) determined the concentration of biological solids in the aeration tank (<xref ref-type="bibr" rid="B11">Metcalf and Eddy, 2003</xref>). The sludge quality data on these operational control parameters are presented in <xref ref-type="table" rid="T3">Table&#x20;3</xref>.</p>
<table-wrap id="T3" position="float">
<label>TABLE 3</label>
<caption>
<p>Process operational parameters related to sludge quality. Waste sludge quantity with respect to total suspended solids its organic fraction, settleability, and biological activity in terms of SOUR.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th rowspan="2" align="center">Parameters</th>
<th rowspan="2" align="center">Unit</th>
<th rowspan="2" align="center">CETP, IIE SIDCUL, Haridwar</th>
<th colspan="2" align="center">CETP, IMT Manesar</th>
<th rowspan="2" align="center">CETP, IIE SIDCUL, Pantnagar</th>
</tr>
<tr>
<th align="center">(25 MLD Stream)</th>
<th align="center">(30 MLD Stream)</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">MLSS</td>
<td align="left">mg/L</td>
<td align="char" char=".">4,268</td>
<td align="char" char=".">6,656</td>
<td align="char" char=".">1971</td>
<td align="char" char=".">2,958</td>
</tr>
<tr>
<td align="left">MLVSS</td>
<td align="left">mg/L</td>
<td align="char" char=".">2,747</td>
<td align="char" char=".">3,240</td>
<td align="char" char=".">920</td>
<td align="char" char=".">1,460</td>
</tr>
<tr>
<td align="left">SV<sub>
<bold>30</bold>
</sub>
</td>
<td align="left">mL/L</td>
<td align="char" char=".">450</td>
<td align="char" char=".">890</td>
<td align="char" char=".">280</td>
<td align="char" char=".">190</td>
</tr>
<tr>
<td align="left">SVI</td>
<td align="left">mL/g</td>
<td align="char" char=".">163.8</td>
<td align="char" char=".">133.7</td>
<td align="char" char=".">149.6</td>
<td align="char" char=".">64.2</td>
</tr>
<tr>
<td align="left">OUR</td>
<td align="left">mg/L.h</td>
<td align="char" char=".">19.56</td>
<td align="char" char=".">36.9</td>
<td align="char" char=".">40.8</td>
<td align="char" char=".">25.6</td>
</tr>
<tr>
<td align="left">SOUR</td>
<td align="left">mg O<sub>2</sub>/gVSS&#x2a;h</td>
<td align="char" char=".">7.13</td>
<td align="char" char=".">11.3</td>
<td align="char" char=".">44</td>
<td align="char" char=".">17.5</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>The CETPs SIDCUL Haridwar, IMT Manesar (both streams), showed the bulky sludge with an SVI value &#x3e; 120&#xa0;ml/g. While in the CETP of SIDCUL Pantnagar, appropriate settling was taking place as the SVI value was &#x3c;120&#xa0;ml/g, which resulted in satisfactory performance of the treatment plant compared to other CETPs. Typically, SOUR, more than 20&#x2013;30&#xa0;mg O<sub>2</sub>/g volatile suspended solids (VSS)&#x2a;h, suggested the rapid uptake of the substrate under a high food/microorganism (F/M) ratio and lower sludge retention time (SRT), however, values of less than 10&#xa0;mg O<sub>2</sub>/gVSS&#x2a;h indicates slower uptake of BOD under lower F/M ratio and high SRT (Metcalf and Eddy, 2003). However, the SOUR of the aeration tank of CETP SIDCUL Haridwar showed &#x3e;10&#xa0;mg O<sub>2</sub>/gVSS&#x2a;h compared to other CETPs of IMT Manesar and SIDCUL Pantnagar, which might be due to the introduction of MBBR unit before aeration tank, showing an enhanced longer SRT and lower F/M in the later aeration stage. Since the CETPs at LRIA and MIA Delhi did not have any biological unit in the treatment process, the process control parameters were not available.</p>
</sec>
<sec id="s3-3">
<title>Performance Evaluations of Common Effluent Treatment Plants</title>
<p>It was difficult to make common criteria of evaluation of the performance of all five CETPs because of the different treatment schemes. Moreover, the variable HRT in types and contributing pollution loads from the contributing industries and changes in the industrial manufacturing process further complicated the performance evaluation. Nevertheless, a consensus close to all the present CETPS was achieved, because the pollution abatement standard parameters were the same. All the plants, irrespective of biological or chemical or combined the common macro pollutant parameters, included COD, BOD, TSS, Nitrogen, Phosphorus, Chloride, Fluoride, Sulphate, and Sulphide, and therefore each was analyzed and evaluated critically, as shown in <xref ref-type="table" rid="T4">Table&#x20;4</xref>. The selection of all heavy metals (14) was so precise that most of them were detected in the samples, as given in <xref ref-type="table" rid="T5">Table&#x20;5</xref>.</p>
<table-wrap id="T4" position="float">
<label>TABLE 4</label>
<caption>
<p>Nutrients and the removal of other contaminants in five different CETPs. Monitoring status of five CETPs in terms of basic pollution parameters namely; COD, BOD, TSS, Nitrogen, Phosphorus, Chloride, Fluoride, Sulphate, and Sulphide.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th rowspan="3" colspan="2" align="center">CETPs</th>
<th rowspan="3" align="center">Sources</th>
<th colspan="11" align="center">Parameters</th>
</tr>
<tr>
<th rowspan="2" align="center">pH</th>
<th align="center">Oil and Grease</th>
<th align="center">NH<sub>4</sub>-N</th>
<th align="center">TKN</th>
<th align="center">NO<sub>3</sub>-N</th>
<th align="center">PO<sub>4</sub>-P</th>
<th align="center">TP</th>
<th align="center">Chlorides</th>
<th align="center">Sulfate, as SO<sub>4</sub>
</th>
<th align="center">Fluoride</th>
<th align="center">Sulfides as S</th>
</tr>
<tr>
<th align="center">mg/L</th>
<th align="center">mg/L</th>
<th align="center">mg/L</th>
<th align="center">mg/L</th>
<th align="center">mg/L</th>
<th align="center">mg/L</th>
<th align="center">mg/L</th>
<th align="center">mg/L</th>
<th align="center">mg/L</th>
<th align="center">mg/L</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td rowspan="6" colspan="2" align="left">4.5 MLD CETP, SIDCUL Haridwar</td>
<td align="left">EQ Tank</td>
<td align="center">7.1</td>
<td align="center">75</td>
<td align="center">47.1</td>
<td align="center">53.3</td>
<td align="center">1.6</td>
<td align="center">3.2</td>
<td align="center">8.6</td>
<td align="center">65</td>
<td align="center">18.9</td>
<td align="center">0.8</td>
<td align="center">2</td>
</tr>
<tr>
<td align="left">PST Outlet</td>
<td align="center">6.9</td>
<td align="center">NA</td>
<td align="center">38.5</td>
<td align="center">NA</td>
<td align="center">2.3</td>
<td align="center">3</td>
<td align="center">4.1</td>
<td align="center">40</td>
<td align="center">17.5</td>
<td align="center">0.74</td>
<td align="center">1.8</td>
</tr>
<tr>
<td align="left">MBBR Outlet</td>
<td align="center">7.2</td>
<td align="center">NA</td>
<td align="center">27</td>
<td align="center">NA</td>
<td align="center">4</td>
<td align="center">2.8</td>
<td align="center">1.8</td>
<td align="center">40</td>
<td align="center">18.3</td>
<td align="center">0.7</td>
<td align="center">1.3</td>
</tr>
<tr>
<td align="left">Clarifier Outlet</td>
<td align="center">7.6</td>
<td align="center">NA</td>
<td align="center">25.9</td>
<td align="center">NA</td>
<td align="center">3.9</td>
<td align="center">2.6</td>
<td align="center">3</td>
<td align="center">40</td>
<td align="center">13.2</td>
<td align="center">0.68</td>
<td align="center">0.9</td>
</tr>
<tr>
<td align="left">PSF Outlet</td>
<td align="center">7.6</td>
<td align="center">NA</td>
<td align="center">24.9</td>
<td align="center">NA</td>
<td align="center">3.8</td>
<td align="center">2.4</td>
<td align="center">3.1</td>
<td align="center">35</td>
<td align="center">8.7</td>
<td align="center">0.63</td>
<td align="center">0.7</td>
</tr>
<tr>
<td align="left">ACF Outlet</td>
<td align="center">7.6</td>
<td align="center">5</td>
<td align="center">26.6</td>
<td align="center">40.2</td>
<td align="center">4.1</td>
<td align="center">2.3</td>
<td align="center">3</td>
<td align="center">32</td>
<td align="center">8.5</td>
<td align="center">0.64</td>
<td align="center">0.7</td>
</tr>
<tr>
<td rowspan="8" align="left">55 MLD CETP, IMT Manesar</td>
<td rowspan="4" align="left">(1st Stream 25 MLD)</td>
<td align="left">EQ Tank</td>
<td align="center">7.59&#x2013;6.53</td>
<td align="center">35.8&#x2013;44.6</td>
<td align="center">20.8&#x2013;24.5</td>
<td align="center">27&#x2013;32.4</td>
<td align="center">0.1&#x2013;7.4</td>
<td align="center">4.8&#x2013;5.8</td>
<td align="center">NA</td>
<td align="center">575&#x2013;650</td>
<td align="center">139.5&#x2013;154.2</td>
<td align="center">1&#x2013;1.5</td>
<td align="center">NA</td>
</tr>
<tr>
<td align="left">PST Outlet</td>
<td align="center">7.55&#x2013;7.57</td>
<td align="center">NA</td>
<td align="center">18.3&#x2013;21.3</td>
<td align="center">NA</td>
<td align="center">0.1&#x2013;6.9</td>
<td align="center">3.8&#x2013;3.7</td>
<td align="center">NA</td>
<td align="center">510&#x2013;610</td>
<td align="center">135.5&#x2013;140.4</td>
<td align="center">0.98&#x2013;0.8</td>
<td align="center">NA</td>
</tr>
<tr>
<td align="left">SST Outlet</td>
<td align="center">7.97&#x2013;7.90</td>
<td align="center">NA</td>
<td align="center">1.4&#x2013;4.4</td>
<td align="center">NA</td>
<td align="center">11.8&#x2013;15.9</td>
<td align="center">3.7&#x2013;3.5</td>
<td align="center">NA</td>
<td align="center">450&#x2013;530</td>
<td align="center">112.9&#x2013;135.6</td>
<td align="center">0.9&#x2013;0.7</td>
<td align="center">NA</td>
</tr>
<tr>
<td align="left">Final Outlet</td>
<td align="center">8.08&#x2013;8.05</td>
<td align="center">15</td>
<td align="center">1.5&#x2013;3.6</td>
<td align="center">3&#x2013;5.2</td>
<td align="center">12.2&#x2013;14.5</td>
<td align="center">3.1&#x2013;3.3</td>
<td align="center">NA</td>
<td align="center">455&#x2013;468</td>
<td align="center">91.9&#x2013;128.6</td>
<td align="center">0.64&#x2013;0.61</td>
<td align="center">NA</td>
</tr>
<tr>
<td rowspan="4" align="left">(2nd Stream 30 MLD)</td>
<td align="left">EQ Tank</td>
<td align="center">7.91&#x2013;7.4</td>
<td align="center">60.2&#x2013;87.6</td>
<td align="center">18.6&#x2013;24.6</td>
<td align="center">23&#x2013;30.1</td>
<td align="center">0.4&#x2013;4.45</td>
<td align="center">4.1&#x2013;5.2</td>
<td align="center">NA</td>
<td align="center">655&#x2013;712</td>
<td align="center">151.6&#x2013;148.3</td>
<td align="center">1.17&#x2013;1.8</td>
<td align="center">NA</td>
</tr>
<tr>
<td align="left">PST Outlet</td>
<td align="center">7.48&#x2013;7.51</td>
<td align="center">NA</td>
<td align="center">23.4&#x2013;22.5</td>
<td align="center">NA</td>
<td align="center">0.3&#x2013;6.35</td>
<td align="center">4.2&#x2013;3.9</td>
<td align="center">NA</td>
<td align="center">640&#x2013;634</td>
<td align="center">134.4&#x2013;139.6</td>
<td align="center">0.99&#x2013;1.2</td>
<td align="center">NA</td>
</tr>
<tr>
<td align="left">SST Outlet</td>
<td align="center">7.91&#x2013;7.7</td>
<td align="center">45.9&#x2013;30.1</td>
<td align="center">6.2&#x2013;10.4</td>
<td align="center">NA</td>
<td align="center">15&#x2013;9.5</td>
<td align="center">4.4&#x2013;3.5</td>
<td align="center">NA</td>
<td align="center">605&#x2013;630</td>
<td align="center">102&#x2013;130</td>
<td align="center">0.70&#x2013;1.2</td>
<td align="center">NA</td>
</tr>
<tr>
<td align="left">Final Outlet</td>
<td align="center">8.08&#x2013;8.1</td>
<td align="center">15</td>
<td align="center">1.5&#x2013;3.6</td>
<td align="center">3&#x2013;5.2</td>
<td align="center">12.2&#x2013;14.5</td>
<td align="center">3.1&#x2013;3.3</td>
<td align="center">NA</td>
<td align="center">455&#x2013;468</td>
<td align="center">91.9&#x2013;128.6</td>
<td align="center">0.64&#x2013;0.61</td>
<td align="center">NA</td>
</tr>
<tr>
<td rowspan="4" colspan="2" align="left">4 MLD CETP, Pantnagar</td>
<td align="left">EQ Tank</td>
<td align="center">7.3</td>
<td align="center">16</td>
<td align="center">10.1</td>
<td align="center">25.3</td>
<td align="center">4</td>
<td align="center">3.2</td>
<td align="center">9.11</td>
<td align="center">62</td>
<td align="center">21.4</td>
<td align="center">0.9</td>
<td align="center">1.8</td>
</tr>
<tr>
<td align="left">PST Outlet</td>
<td align="center">7.1</td>
<td align="center">2</td>
<td align="center">9.3</td>
<td align="center">20.6</td>
<td align="center">2</td>
<td align="center">2.9</td>
<td align="center">7.6</td>
<td align="center">47</td>
<td align="center">16.4</td>
<td align="center">0.63</td>
<td align="center">1.6</td>
</tr>
<tr>
<td align="left">SST Outlet</td>
<td align="center">7.3</td>
<td align="center">1</td>
<td align="center">2.6</td>
<td align="center">5.6</td>
<td align="center">9</td>
<td align="center">2.8</td>
<td align="center">2.14</td>
<td align="center">35</td>
<td align="center">11.1</td>
<td align="center">0.52</td>
<td align="center">0.9</td>
</tr>
<tr>
<td align="left">Final Outlet</td>
<td align="center">7.5</td>
<td align="center">0</td>
<td align="center">2.3</td>
<td align="center">2.8</td>
<td align="center">8</td>
<td align="center">0.76</td>
<td align="center">1.88</td>
<td align="center">18</td>
<td align="center">9</td>
<td align="center">0.49</td>
<td align="center">0.8</td>
</tr>
<tr>
<td rowspan="2" colspan="2" align="left">12 MLD CETP, LRIA, Delhi</td>
<td align="left">Inlet</td>
<td align="center">7</td>
<td align="center">24</td>
<td align="center">24.8</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="center">4.1</td>
<td align="center">NA</td>
<td align="center">1,050</td>
<td align="center">188.6</td>
<td align="center">0.4</td>
<td align="center">6.11</td>
</tr>
<tr>
<td align="left">Outlet</td>
<td align="center">7.6</td>
<td align="center">2.8</td>
<td align="center">21.6</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="center">2.7</td>
<td align="center">NA</td>
<td align="center">760</td>
<td align="center">127.5</td>
<td align="center">0.1</td>
<td align="center">1.79</td>
</tr>
<tr>
<td rowspan="2" colspan="2" align="left">12 MLD CETP, MIA, Delhi</td>
<td align="left">Inlet</td>
<td align="center">7.3</td>
<td align="center">24.4</td>
<td align="center">16</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="center">4.1</td>
<td align="center">NA</td>
<td align="center">290</td>
<td align="center">149.3</td>
<td align="center">0.6</td>
<td align="center">7.2</td>
</tr>
<tr>
<td align="left">Outlet</td>
<td align="center">8.1</td>
<td align="center">4</td>
<td align="center">14.9</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="center">2.7</td>
<td align="center">NA</td>
<td align="center">205</td>
<td align="center">108.7</td>
<td align="center">0.31</td>
<td align="center">6.9</td>
</tr>
<tr>
<td colspan="3" align="left">Effluent Discharge Standards</td>
<td align="center">5.5&#x2013;9</td>
<td align="center">10</td>
<td align="center">50</td>
<td align="center">100</td>
<td align="center">10</td>
<td align="center">5</td>
<td align="center">NC</td>
<td align="center">1,000</td>
<td align="center">1,000</td>
<td align="center">2</td>
<td align="center">2.8</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn>
<p>NA-Not available.</p>
</fn>
</table-wrap-foot>
</table-wrap>
<table-wrap id="T5" position="float">
<label>TABLE 5</label>
<caption>
<p>Heavy metal concentrations and removal in percentage. Detailed 14 selected heavy metal analyses at the inlet and outlet of each treatment unit operation/process in all CETPS.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th rowspan="3" colspan="2" align="left">CETPs</th>
<th rowspan="3" align="center">Sources</th>
<th colspan="15" align="center">Heavy Metals</th>
</tr>
<tr>
<th align="center">Zn</th>
<th align="center">Fe</th>
<th align="center">Cu</th>
<th align="center">Cr</th>
<th align="center">Mn</th>
<th align="center">Ni</th>
<th align="center">As</th>
<th align="center">V</th>
<th align="center">Pb</th>
<th align="center">Se</th>
<th align="center">Cd</th>
<th align="center">Hg</th>
<th align="center">Co</th>
<th align="center">Al</th>
<th align="center">B</th>
</tr>
<tr>
<th align="center">mg/L</th>
<th align="center">mg/L</th>
<th align="center">mg/L</th>
<th align="center">mg/L</th>
<th align="center">mg/L</th>
<th align="center">mg/L</th>
<th align="center">mg/L</th>
<th align="center">mg/L</th>
<th align="center">mg/L</th>
<th align="center">mg/L</th>
<th align="center">mg/L</th>
<th align="center">mg/L</th>
<th align="center">mg/L</th>
<th align="center">mg/L</th>
<th align="center">mg/L</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td rowspan="2" colspan="2" align="left">4.5 MLD CETP, SIDCUL Haridwar</td>
<td align="left">EQ Tank</td>
<td align="char" char=".">0.81</td>
<td align="center">3.35</td>
<td align="char" char=".">0.85</td>
<td align="center">5.23</td>
<td align="char" char=".">0.07</td>
<td align="char" char=".">0.61</td>
<td align="center">0.003</td>
<td align="center">57.04</td>
<td align="char" char=".">0.17</td>
<td align="center">4.77</td>
<td align="char" char=".">0.001</td>
<td align="center">0.53</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="center">NA</td>
</tr>
<tr>
<td align="left">ASF Outlet</td>
<td align="char" char=".">0.59</td>
<td align="center">0.89</td>
<td align="char" char=".">0.046</td>
<td align="center">0.09</td>
<td align="char" char=".">0.06</td>
<td align="char" char=".">0.26</td>
<td align="center">0.001</td>
<td align="center">29.42</td>
<td align="char" char=".">0.01</td>
<td align="center">2.74</td>
<td align="char" char=".">0</td>
<td align="center">0.48</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="center">NA</td>
</tr>
<tr>
<td rowspan="8" align="left">55 MLD CETP, IMT Manesar</td>
<td rowspan="4" align="left">(1st Stream 25 MLD)</td>
<td align="left">EQ Tank</td>
<td align="char" char=".">2.61</td>
<td align="center">NA</td>
<td align="char" char=".">0.49</td>
<td align="center">0.75</td>
<td align="char" char=".">0.15</td>
<td align="char" char=".">1.18</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="char" char=".">0.25</td>
<td align="center">NA</td>
<td align="char" char=".">0.42</td>
<td align="center">NA</td>
<td align="center">0.02</td>
<td align="center">2.04</td>
<td align="center">4.29</td>
</tr>
<tr>
<td align="left">PST Outlet</td>
<td align="char" char=".">1.75</td>
<td align="center">NA</td>
<td align="char" char=".">0.16</td>
<td align="center">0.14</td>
<td align="char" char=".">0.13</td>
<td align="char" char=".">0.37</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="char" char=".">0.1</td>
<td align="center">NA</td>
<td align="char" char=".">0.34</td>
<td align="center">NA</td>
<td align="center">0.01</td>
<td align="center">0.63</td>
<td align="center">8.33</td>
</tr>
<tr>
<td align="left">SST Outlet</td>
<td align="char" char=".">1.29</td>
<td align="center">NA</td>
<td align="char" char=".">0.04</td>
<td align="center">0.1</td>
<td align="char" char=".">0.05</td>
<td align="char" char=".">0.25</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="char" char=".">0.04</td>
<td align="center">NA</td>
<td align="char" char=".">0.12</td>
<td align="center">NA</td>
<td align="center">0.01</td>
<td align="center">0.58</td>
<td align="center">6.21</td>
</tr>
<tr>
<td align="left">Final Outlet</td>
<td align="char" char=".">2.45</td>
<td align="center">NA</td>
<td align="char" char=".">0.3</td>
<td align="center">0.51</td>
<td align="char" char=".">0.22</td>
<td align="char" char=".">0.46</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="char" char=".">0.05</td>
<td align="center">NA</td>
<td align="char" char=".">0.04</td>
<td align="center">NA</td>
<td align="center">0.01</td>
<td align="center">0.8</td>
<td align="center">5.11</td>
</tr>
<tr>
<td rowspan="4" align="left">(2nd Stream 30 MLD)</td>
<td align="left">EQ Tank</td>
<td align="char" char=".">4.31</td>
<td align="center">NA</td>
<td align="char" char=".">0.46</td>
<td align="center">0.66</td>
<td align="char" char=".">0.12</td>
<td align="char" char=".">0.92</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="char" char=".">0.07</td>
<td align="center">NA</td>
<td align="char" char=".">0.2</td>
<td align="center">NA</td>
<td align="center">0.01</td>
<td align="center">1.8</td>
<td align="center">4.29</td>
</tr>
<tr>
<td align="left">PST Outlet</td>
<td align="char" char=".">3.53</td>
<td align="center">NA</td>
<td align="char" char=".">0.18</td>
<td align="center">0.43</td>
<td align="char" char=".">0.11</td>
<td align="char" char=".">0.48</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="char" char=".">0.06</td>
<td align="center">NA</td>
<td align="char" char=".">0.09</td>
<td align="center">NA</td>
<td align="center">0.01</td>
<td align="center">0.92</td>
<td align="center">3.97</td>
</tr>
<tr>
<td align="left">SST Outlet</td>
<td align="char" char=".">4.24</td>
<td align="center">NA</td>
<td align="char" char=".">0.09</td>
<td align="center">0.15</td>
<td align="char" char=".">0.08</td>
<td align="char" char=".">0.13</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="char" char=".">0.05</td>
<td align="center">NA</td>
<td align="char" char=".">0.17</td>
<td align="center">NA</td>
<td align="center">0.01</td>
<td align="center">0.68</td>
<td align="center">3.44</td>
</tr>
<tr>
<td align="left">Final Outlet</td>
<td align="char" char=".">2.45</td>
<td align="center">NA</td>
<td align="char" char=".">0.3</td>
<td align="center">0.51</td>
<td align="char" char=".">0.22</td>
<td align="char" char=".">0.46</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="char" char=".">0.05</td>
<td align="center">NA</td>
<td align="char" char=".">0.04</td>
<td align="center">NA</td>
<td align="center">0.01</td>
<td align="center">0.8</td>
<td align="center">3.24</td>
</tr>
<tr>
<td rowspan="2" colspan="2" align="left">4 MLD CETP, Pantnagar</td>
<td align="left">EQ Tank</td>
<td align="char" char=".">0.81</td>
<td align="center">3.35</td>
<td align="char" char=".">0.85</td>
<td align="center">5.23</td>
<td align="char" char=".">0.07</td>
<td align="char" char=".">0.61</td>
<td align="center">0.003</td>
<td align="center">57.04</td>
<td align="char" char=".">0.17</td>
<td align="center">4.77</td>
<td align="char" char=".">0.001</td>
<td align="center">0.53</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="center">NA</td>
</tr>
<tr>
<td align="left">Final Outlet</td>
<td align="char" char=".">0.59</td>
<td align="center">0.89</td>
<td align="char" char=".">0.046</td>
<td align="center">0.09</td>
<td align="char" char=".">0.06</td>
<td align="char" char=".">0.26</td>
<td align="center">0.001</td>
<td align="center">29.42</td>
<td align="char" char=".">0.01</td>
<td align="center">2.74</td>
<td align="char" char=".">0</td>
<td align="center">0.48</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="center">NA</td>
</tr>
<tr>
<td rowspan="2" colspan="2" align="left">12 MLD CETP, LRIA, Delhi</td>
<td align="left">Inlet</td>
<td align="char" char=".">0.55</td>
<td align="center">NA</td>
<td align="char" char=".">1.15</td>
<td align="center">NA</td>
<td align="char" char=".">0.21</td>
<td align="char" char=".">1.55</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="char" char=".">0.21</td>
<td align="center">NA</td>
<td align="char" char=".">0</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="center">NA</td>
</tr>
<tr>
<td align="left">Outlet</td>
<td align="char" char=".">0</td>
<td align="center">NA</td>
<td align="char" char=".">0.02</td>
<td align="center">0.64</td>
<td align="char" char=".">0.25</td>
<td align="char" char=".">1.14</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="char" char=".">0</td>
<td align="center">NA</td>
<td align="char" char=".">0</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="center">NA</td>
</tr>
<tr>
<td rowspan="2" colspan="2" align="left">12 MLD CETP, MIA, Delhi</td>
<td align="left">Inlet</td>
<td align="char" char=".">1.17</td>
<td align="center">NA</td>
<td align="char" char=".">2.97</td>
<td align="center">0.37</td>
<td align="char" char=".">0.22</td>
<td align="char" char=".">3.7</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="char" char=".">0.16</td>
<td align="center">NA</td>
<td align="char" char=".">1.64</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="center">NA</td>
</tr>
<tr>
<td align="left">Outlet</td>
<td align="char" char=".">0.55</td>
<td align="center">NA</td>
<td align="char" char=".">0.04</td>
<td align="center">0.24</td>
<td align="char" char=".">0.19</td>
<td align="char" char=".">1.14</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="char" char=".">0.05</td>
<td align="center">NA</td>
<td align="char" char=".">0.73</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="center">NA</td>
<td align="center">NA</td>
</tr>
<tr>
<td colspan="3" align="left">Effluent Discharge Standards</td>
<td align="char" char=".">5</td>
<td align="center">3</td>
<td align="char" char=".">3</td>
<td align="center">2</td>
<td align="char" char=".">2</td>
<td align="char" char=".">3</td>
<td align="center">0.2</td>
<td align="center">NC</td>
<td align="char" char=".">0.1</td>
<td align="center">0.05</td>
<td align="char" char=".">1</td>
<td align="center">0.01</td>
<td align="center">NC</td>
<td align="center">NC</td>
<td align="center">2</td>
</tr>
</tbody>
</table>
</table-wrap>
<sec id="s3-3-1">
<title>Organic Matter Removal</title>
<p>The efficiency of plants is generally measured in terms of the removal of organic matters. All the CETPs in North India are designed to produce an effluent COD of less than 250&#xa0;mg/L, a BOD of less than 30&#xa0;mg/L, and a TSS of less than 100&#xa0;mg/L (CPHEEO, 2013). <xref ref-type="fig" rid="F7">Figure&#x20;7</xref> presents the removal of the target parameters of the CETPs included in the present&#x20;study.</p>
<fig id="F7" position="float">
<label>FIGURE 7</label>
<caption>
<p>THe concentration of COD, BOD, and TSS in different optionl units of CETPs and removal efficiencies.</p>
</caption>
<graphic xlink:href="fenvs-09-741343-g007.tif"/>
</fig>
<p>
<bold>Evaluation of SIDCUL CETP, Haridwar</bold> It was observed that the total COD, BOD, and TSS in the influent were 883&#xa0;mg/L, 426&#xa0;mg/L, and 460&#xa0;mg/L respectively, which was reduced to 731, 389, 380&#xa0;mg/L after primary settling tank (PST). The 17, 9, and 17% removal efficiencies were followed by 170, 100, 125&#xa0;mg/L. The 77, 74, and 67% removal efficiencies in the effluent of the MBBR tank, had 55&#xa0;mg/L, 20&#xa0;mg/L, and 17&#xa0;mg/L. The 68, 80, and 86% removal efficiencies after the SST were further reduced to 43&#xa0;mg/L 11&#xa0;mg/L, and 8&#xa0;mg/L. There were 23, 40, and 53% removal efficiencies in the PSF and ACF units. The overall removal efficiencies of the COD, BOD, and TSS of the plant were found to be 79, 85, and 85%, respectively.</p>
<p>
<bold>In the CETP at IMT Manesar,</bold> the influent COD of 25 and 30 MLD streams varied from 563 to 524&#xa0;mg/L and 574&#x2013;472&#xa0;mg/L, which was reduced to 406&#x2013;392&#xa0;mg/L and 485&#x2013;362&#xa0;mg/L after PST. The removal efficiency of the chemically treated PST system was 28 and 25% for the 25 MLD stream and 16 and 23% for the 30 MLD stream. Generally, the COD removal efficiency of chemically treated PST systems varied from 20 to 40%, and any value of less than 20% was considered acceptable. During the first sampling operation of 30 MLD CETP, the primary treatment system was not functioning properly, and the efficiency was only 16%; however, during the second sampling operation the chemical dosing was adjusted and the efficiency improved to&#x20;30%.</p>
<p>The COD was further reduced to 132&#x2013;72&#xa0;mg/L and 126&#x2013;76&#xa0;mg/L by SST of both 25 and 30 MLD streams. The removal efficiencies of SST were 67 and 81% for 25 MLD stream and 74 and 79% for 30 MLD stream. Meanwhile, the COD removal efficiency of the biological treatment system varied from 80 to 95%; which was well above the minimum acceptable level of&#x20;70%.</p>
<p>The secondary treated effluent COD was further reduced to 63&#x2013;27&#xa0;mg/L by sand filtration. The sand filtered effluent COD of the combined 25 and 30 MLD streams was 63&#xa0;mg/L on first sampling, which was reduced to 27&#xa0;mg/L on second sampling by adopting standard operating procedures such as regular filter backwashing. The influent BOD of 25 and 30 MLD streams varied from 240&#x2013;255 and 237&#x2013;271&#xa0;mg/L, which reduced to 190&#x2013;195 and 220&#x2013;188&#xa0;mg/L after PST. The removal efficiency of the chemical pre-treatment system was 20.8 and 23.5% for the 25 MLD stream and 7 and 30.6% for the 30 MLD stream. Meanwhile, the BOD removal efficiency of the chemical pre-treatment system varied from 20 to 40%. During the first sampling of the 30 MLD stream, the primary treatment system was not functioning properly, and the efficiency was only 7%; however, after adjusting chemical dosing, the efficiency improved to 30% on the second sampling.</p>
<p>The BOD was further reduced to 42&#x2013;13&#xa0;mg/L and 60&#x2013;30&#xa0;mg/L by biological treatment of both 25 and 30 MLD streams, which resulted in 77&#x2013;95% and 72&#x2013;84% efficiencies for the respective streams. This value was well above the minimum removal of 70%, however, there was still scope for improvement. The improvement in the efficiency of both CETPs was observed in the second sampling due to regular sludge wastage.</p>
<p>The secondary treated effluent BOD was further reduced from 28 on first sampling to 5&#xa0;mg/L by sand filtration on second sampling. Hence, the CETP satisfied the effluent BOD standard for reuse. The inlet TSS of the 25 and 30 MLD CETPs varied from 211&#x2013;370 to 276&#x2013;309&#xa0;mg/L, which reduced to 134&#x2013;200 and 171&#x2013;230&#xa0;mg/L after primary chemical treatment. The removal efficiency of the chemical pre-treatment system was 36 and 46% for the 25 MLD stream and 38 and 26% for 30 MLD stream. These values indicated that the primary treatment system fairly removed the TSS from the raw influent.</p>
<p>The TSS was further reduced to 17&#x2013;40&#xa0;mg/L and 33&#x2013;20&#xa0;mg/L by biological treatment of the 25 and 30 MLD streams. The removal efficiency of biological treatment was 87 and 80% for the 25 MLD stream and 81 and 91% for the 30 MLD stream, meaning the biological treatment system removed the desired level of TSS from the effluent.</p>
<p>The secondary treated effluent TSS was further reduced from 30 during the first sampling and to 8&#xa0;mg/L by sand filtration during the second sampling. Hence, the CETP satisfied the effluent TSS standard for&#x20;reuse.</p>
<p>
<bold>Evaluation of 12 MLD CETP at LRIA, Delhi.</bold> Given the two-point sampling of CETP at LRIA (Inlet and Outlet), it was observed that the BOD of raw effluent reaching the CETP corresponded to diluted sewage. However, BOD was consistently above the original design value of 89&#xa0;mg/L. The average BOD was found to have come down from around 120&#xa0;mg/l to 35&#x2013;40&#xa0;mg/l (67&#x2013;71% removal efficiency), which was marginally above the discharge limit of 30&#xa0;mg/L. The COD of raw effluent was 340&#xa0;mg/L, which was reduced to 128&#xa0;mg/L in the treated effluent, resulting in 62% removal efficiency. TSS reduction was from 268&#xa0;mg/L to 76&#xa0;mg/L, thereby giving 72% removal efficiency.</p>
<p>
<bold>Evaluation of 12 MLD MIA CETP at Delhi</bold> observed that the BOD of raw effluent reaching the CETP corresponded to diluted sewage. However, BOD was consistently below the original design value of 89&#xa0;mg/L. For instance, BOD was reduced from around 76&#xa0;mg/l down to 28&#xa0;mg/l, which was marginally below the discharge limit of 30&#xa0;mg/L. The removal of BOD was found to be 63%. The COD of the raw effluent was 220&#xa0;mg/L, which was reduced to 100&#xa0;mg/L in the treated effluent. The removal efficiency for COD was found to be 55%. The TSS in the raw wastewater was 148&#xa0;mg/L and reduced to 66&#xa0;mg/L in treated effluent with a removal efficiency of&#x20;54%.</p>
<p>
<bold>In the CETP 4 MLD Pantnagar</bold> it was observed that the COD, BOD and TSS in the influent were 480&#xa0;mg/L, 127&#xa0;mg/L and 269&#xa0;mg/L respectively, which were reduced to 250, 69, 145&#xa0;mg/L after PST (48, 46 and 46% removal efficiencies), followed by 57, 13, 59&#xa0;mg/L (77, 81and 69% removal) in SST outlet, and further dropped to 46&#xa0;mg/L, 11&#xa0;mg/L and 20&#xa0;mg/L (19, 15 and 66% removal efficiencies) after the sand filtration. The overall COD, BOD, and TSS removal efficiencies of the plant were found to be 90%, &#x3e;92%, and 93%, respectively.</p>
</sec>
<sec id="s3-3-2">
<title>Nutrient Removal</title>
<p>
<xref ref-type="table" rid="T4">Table&#x20;4</xref> shows the comparative overview of the CETPs regarding nutrients and other contaminant removal in relation to treated effluent discharge standards (<xref ref-type="bibr" rid="B13">Ministry of Environment Forest and Climate Change MoEFCC, 2016</xref>).</p>
<p>
<bold>CETP 4.5 MLD SIDCUL Haridwar.</bold> Regarding nitrogen removal efficiency, the present analysis results showed that the concentration of ammonia nitrogen decreased from 47.1&#xa0;mg/L in influent to 26.6&#xa0;mg/L in final effluent (43.5% removal). Even though the concentration of ammonia in the effluent was higher, the quality was below effluent discharge standards. A similar scenario was observed for nitrate levels (influent 1.6&#xa0;mg/L, effluent 4.1&#xa0;mg/L) and TKN (influent 53.3&#xa0;mg/L, effluent 40.2&#xa0;mg/L), thereby satisfying effluent standards. Total nitrogen in the influent was 54.9&#xa0;mg/L, which was reduced 44.3&#xa0;mg/L after PSF and ACF units (19.3% removal). Concerning phosphorus removal, the <italic>ortho</italic>-phosphate decreased from 3.2&#xa0;mg/L to 2.3&#xa0;mg/L. The total phosphorus in the influent was 8.6&#xa0;mg/L, which was reduced to 3&#xa0;mg/L after PSF and ACF units (65.2% removal). Inlet oil and grease (O and G) of the plant was 75&#xa0;mg/L, which reduced to 5&#xa0;mg/L after tertiary treatment, and conformed to effluent treatment standards. It was observed that the Chloride (as Cl), Fluoride (as F), Sulphate (as SO<sub>4</sub>), and Sulphide (as S) in the influent were 65&#xa0;mg/L, 0.8&#xa0;mg/L, 18.9&#xa0;mg/L, and 2&#xa0;mg/L respectively, which was reduced to 32&#xa0;mg/L, 0.64&#xa0;mg/L, 8.5&#xa0;mg/L, and 0.7&#xa0;mg/L respectively (50.8, 20, 55 and 65% removal efficiencies) after PSF and ACF&#x20;unit.</p>
<p>
<bold>In the CETP 55 MLD at IMT Manesar.</bold> Regarding nitrogen removal efficiency, <xref ref-type="table" rid="T2">Table&#x20;2</xref> shows the average concentration of ammonia nitrogen for the two sampling campaigns. The inlet ammonia nitrogen of 25 and 30 MLD CETPs varied from 20.8&#x2013;24.5&#xa0;mg/L and 18.6&#x2013;24.6&#xa0;mg/L, which reduced to 1.5&#x2013;3.6 and 1.5&#x2013;3.6&#xa0;mg/L on effluent after final treatment. The removal efficiency was 85&#x2013;92% for 25 MLD CETP and 85&#x2013;91% for 30 MLD CETP. Although the concentration of ammonia in the effluent was higher, the quality was below the effluent discharge standards in both the 25 MLD and 30 MLD CETPs.</p>
<p>Similar scenario was observed for nitrate (influent 0.1&#x2013;7.4&#xa0;mg/L in 25 MLD and 0.4&#x2013;4.5&#xa0;mg/L in 30 MLD CETPs and effluent 12.2&#x2013;14.5&#xa0;mg/L in 25 MLD, and again 12.2&#x2013;14.5 in 30 MLD CETPs) and TKN (in influent 27&#x2013;32.4&#xa0;mg/L in 25 MLD and 23&#x2013;30.1&#xa0;mg/L in 30 MLD CETPs and in effluent 3&#x2013;5.2&#xa0;mg/L in 25 MLD and again 3&#x2013;5.2 in 30 MLD CETP), conforming to effluent standards. The total nitrogen of the 25 and 30 MLD CETP varied from 27.1&#x2013;39.8 and 23.4&#x2013;34.5&#xa0;mg/L, which reduced to 15.2&#x2013;19.7 and again to 15.2&#x2013;19.7&#xa0;mg/L in effluent after final treatment. The removal efficiency was 43&#x2013;50% for 25 MLD CETP and 35&#x2013;42% for 30 MLD CETP. Ortho-phosphorus (In influent 4.8&#x2013;5.8&#xa0;mg/L in 25 MLD and 4.1&#x2013;5.2&#xa0;mg/L in 30 MLD CETP and in effluent 3.1&#x2013;3.3&#xa0;mg/L in 25 MLD and again 3.1&#x2013;3.3 in 30 MLD CETP) satisfying effluent standards. The inlet oil and grease of the 25 and 30 MLD CETPs varied from 35.8&#x2013;44.6 to 60.2&#x2013;87.6&#xa0;mg/L, and reduced to 10&#x2013;15&#xa0;mg/L after tertiary treatment.</p>
<p>It was observed that the Inlet Chloride (as Cl) levels of 25 and 30 MLD CETP varied from 575 to 650&#xa0;mg/L and 655&#x2013;712&#xa0;mg/L, which reduced to 455&#x2013;468&#xa0;mg/L (20&#x2013;28 and 30&#x2013;34% removal in 25 and 30 MLD CETP, respectively) after tertiary treatment. It was observed that the Fluoride (as F) of the 25 and 30 MLD CETP varied from 1 to 1.5&#xa0;mg/L to 1.17&#x2013;1.8&#xa0;mg/L, which reduced to 0.61&#x2013;0.64&#xa0;mg/L (39&#x2013;57 and 47&#x2013;65% removal in 25 and 30 MLD CETPs respectively) after tertiary treatment. The Sulphate (as SO<sub>4</sub>) in the 25 and 30 MLD CETP varied from 140 to 155&#xa0;mg/L to 149&#x2013;152&#xa0;mg/L, and reduced to 92&#x2013;122&#xa0;mg/L (21&#x2013;34 and 21&#x2013;38% removal in 25 and 30 MLD CETPs respectively) after tertiary treatment.</p>
<p>
<bold>CETP 12 MLD LRIA, Delhi.</bold> Regarding nitrogen removal efficiency, the present analysis results indicated that the concentration of ammonia nitrogen decreased from 24.8&#xa0;mg/L in influent to 21.6&#xa0;mg/L in final effluent (13% removal efficiency). Eventhough the concentration of ammonia in the effluent is higher, the quality is below effluent discharge standards. Concerning phosphorus removal, the <italic>ortho</italic>-phosphate decreased from 4.1 to 2.7, which was below the effluent discharge standard. The inlet oil and grease of the plant was 24&#xa0;mg/L, which was reduced to 2.8&#xa0;mg/L after tertiary treatment. However, the sample taken after the removal of a malfunctioning oil and grease removal mechanism satisfied the oil and grease effluent standard of 5&#xa0;mg/L. It was observed that the Chloride (as Cl), Fluoride (as F), Sulphate (as SO<sub>4</sub>), and Sulphide (as S) in the influent were 1,050&#xa0;mg/L, 0.4&#xa0;mg/L, 188.6&#xa0;mg/L, and 6.11&#xa0;mg/L, which were reduced to 760&#xa0;mg/L, 0.1&#xa0;mg/L, 127.5&#xa0;mg/L, and 1.8&#xa0;mg/L respectively (28, 75, 33 and 71% removal efficiencies) after tertiary treatment.</p>
<p>
<bold>In the CETP 12 MLD MIA, Delhi.</bold> For nitrogen removal efficiency, the present analysis results showed that the concentration of ammonia nitrogen decreased from 16&#xa0;mg/L in influent to 14.9&#xa0;mg/L in final effluent (7% removal efficiencies). Despite the fact that the concentration of ammonia in the effluent is higher, the quality was below effluent discharge standards. With respect to phosphorus removal, the <italic>ortho</italic>-phosphate decreased from 4.1 to 2.7&#xa0;mg/L, which is below the effluent discharge standard. The inlet oil and grease of the plant was 24.4&#xa0;mg/L, which reduced to 4&#xa0;mg/L after tertiary treatment. The system did satisfy the oli and grease effluent standard of 5&#xa0;mg/L. It was observed that the Chloride (as Cl), Fluoride (as F), Sulphate (as SO<sub>4</sub>), and Sulphide (as S) in the influent were 290&#xa0;mg/L, 0.6&#xa0;mg/L, 149.3&#xa0;mg/L, and 7.2&#xa0;mg/L, which reduced to 205&#xa0;mg/L, 0.31&#xa0;mg/L, 108.7&#xa0;mg/L, and 6.9&#xa0;mg/L, respectively (30, 49, 28 and 5% removal efficiencies) after tertiary treatment.</p>
<p>
<bold>In the CETP 4.0 MLD IIE Pantnagar SIDCUL.</bold> the Nitrogen removal results showed that the concentration of ammonia nitrogen decreased from 10.1&#xa0;mg/L in the influent to 2.3&#xa0;mg/L in the final effluent (77% removal efficiency); however, the concentration of ammonia in the effluent was lower, meaning it was below effluent discharge standards. For phosphorus removal, the <italic>ortho</italic>-phosphate decreased from 3.2 to 0.46&#xa0;mg/L, which was also below the effluent discharge standard. It was observed that the Chloride (as Cl), Fluoride (as F), Sulphate (as SO<sub>4</sub>), and Sulphide (as S) in the influent were 62&#xa0;mg/L, 0.9&#xa0;mg/L, 21.4&#xa0;mg/L, and 1.8&#xa0;mg/L, which reduced to 18.0&#xa0;mg/L, 0.49&#xa0;mg/L, 9.0&#xa0;mg/L, and 0.8&#xa0;mg/L respectively (70, 45, 57, and 55% removal efficiencies) after sand filtration.</p>
</sec>
<sec id="s3-3-3">
<title>Heavy Metal Removal</title>
<p>As the influents to the CETPs were a mixture of both industrial and domestic discharge, heavy metals were present. <xref ref-type="table" rid="T5">Table&#x20;5</xref> shows a comparative overview of the CETPs regarding heavy metal concentrations and removal and the standards for discharge after treatment. The heavy metals were contributed to by untreated discharge from electrical, electronics, electroplating, and allied industries present in the industrial area, even though these CETPs were not originally designed for the removal of heavy metals as per discharge standards. Various methods for the removal of heavy metals exist in practice and their removal by chemical precipitation at varying pH has been found suitable and economical. The amount of alum and polyelectrolyte was also determined using the Jar Test. The pH was adjusted from 7.5 to 11, by NaOH initially followed by lime. The effluent in each case was analyzed for heavy metals at varying pH. It was found that at a pH value of 8, the removal percentages of most of the heavy metals was high, depending on individual solubility. The percentage of removal of various heavy metals varied from 50 to 100% in the case of precipitation by NaOH and 21&#x2013;77% in the case of precipitation by lime. Analysis was conducted on 15 elements, the concentration of 14 elements, which includes Zn, Fe, Cu, Cr, Mn, Ni, As, V, Pb, Se, Cd, Hg, Co, and Al, which were within the Indian CETP effluent discharge standards MoEFCC, 2016), except for Boron (B), which was higher in 55 MLD IMT Manesar. The percentage of removal of heavy metals varied from 65 to&#x20;95%.</p>
</sec>
</sec>
<sec id="s3-4">
<title>Evaluation of the IE of the Common Effluent Treatment Plants</title>
<p>From the above results indicate that these CETPs exhibit different physical and chemical efficiencies depending upon influent characteristics (domestic and industrial sewage), the percentage of capacity utilization, and operating parameters, etc. There is thus a need to define one common parameter that could determine the overall efficiency of CETPs in terms of physical and chemical removal efficiencies As determined by <xref ref-type="bibr" rid="B4">Colmenarejo et&#x20;al. (2006)</xref>, overall efficiency takes into account the average TSS, COD, BOD, and Nitrogen removal efficiencies. The actual and standard IE (Integrated Efficiencies) for CETPs were determined by taking into consideration COD, BOD, TSS, Ammonia, Chlorides, Sulfate (as SO<sub>4</sub>), and Phosphorus removal. Calculations of actual and standard integrated efficiencies (IE<sub>a</sub> and IE<sub>s</sub>) for each CETP were based on effluent sewage characteristics.<disp-formula id="e1">
<mml:math id="m1">
<mml:mrow>
<mml:mi>I</mml:mi>
<mml:mi>E</mml:mi>
<mml:mi>a</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mn>1</mml:mn>
<mml:mn>7</mml:mn>
</mml:mfrac>
<mml:mi>E</mml:mi>
<mml:mi>C</mml:mi>
<mml:mi>O</mml:mi>
<mml:mi>D</mml:mi>
<mml:mo>&#x2b;</mml:mo>
<mml:mi>E</mml:mi>
<mml:mi>B</mml:mi>
<mml:mi>O</mml:mi>
<mml:mi>D</mml:mi>
<mml:mo>&#x2b;</mml:mo>
<mml:mi>E</mml:mi>
<mml:mi>T</mml:mi>
<mml:mi>S</mml:mi>
<mml:mi>S</mml:mi>
<mml:mo>&#x2b;</mml:mo>
<mml:mi>E</mml:mi>
<mml:mi>N</mml:mi>
<mml:mi>H</mml:mi>
<mml:mn>4</mml:mn>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>N</mml:mi>
<mml:mo>&#x2b;</mml:mo>
<mml:mi>E</mml:mi>
<mml:mi>C</mml:mi>
<mml:mi>h</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>o</mml:mi>
<mml:mi>r</mml:mi>
<mml:mi>i</mml:mi>
<mml:mi>d</mml:mi>
<mml:mi>e</mml:mi>
<mml:mo>&#x2b;</mml:mo>
<mml:mi>E</mml:mi>
<mml:mi>S</mml:mi>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>p</mml:mi>
<mml:mi>h</mml:mi>
<mml:mi>a</mml:mi>
<mml:mi>t</mml:mi>
<mml:mi>e</mml:mi>
<mml:mo>&#x2b;</mml:mo>
<mml:mi>E</mml:mi>
<mml:mi>P</mml:mi>
<mml:mi>O</mml:mi>
<mml:mn>4..........................</mml:mn>
</mml:mrow>
</mml:math>
<label>1</label>
</disp-formula>Where IE<sub>a</sub> is the actual integrated efficiency in (%), and all others are the average % removal efficiency of the individual parameter suffixed. To evaluate IE (Integrated efficiency), the average individual removal efficiencies of the CETPs were determined (<xref ref-type="fig" rid="F8">Figure&#x20;8</xref>).</p>
<fig id="F8" position="float">
<label>FIGURE 8</label>
<caption>
<p>
<bold>(A)</bold> Percentage removal of physicochemical parameters. <bold>(B)</bold> Comparison of actual and Standard integrated efficiencies.</p>
</caption>
<graphic xlink:href="fenvs-09-741343-g008.tif"/>
</fig>
<p>The actual integrated efficiency (IE<sub>a</sub>) based on actual effluent quality, and standard integrated efficiency, based on standard effluent discharge standards of the respective plants were evaluated and compared, as shown in <xref ref-type="fig" rid="F8">Figure&#x20;8</xref>. The IE<sub>a</sub> was found to be higher than IE<sub>s</sub> (in the range of 52&#x2013;80% except for the case of the 12 MLD LRIA plant, where the IE<sub>a</sub> was 20% lower than IEs, which was because the CETP was not equipped with a biological unit process for the removal of organic matter. The 4.5 MLD SIDCUL CETP Haridwar, attained 80% IE<sub>a</sub>, the highest in all five CETPS, whereas the IE<sub>a</sub> of the 55 MLD Manesar (both first and second streams) was 79 and 79.5% respectively. The IE<sub>a</sub> of the 12 MLD MIA was above IE<sub>s,</sub> but its actual Integrated Efficiency was the same as the 12 MLD LRIA Delhi, which was also due to the absence of a biological unit process for the removal of organic matter.</p>
</sec>
<sec id="s3-5">
<title>Combined Coagulation Followed by Ultrafiltration and Ozonation Treating Secondary Effluent From CETP for Non-potable Water Reuse</title>
<p>It was observed that the BOD reduced by 77%, COD reduced by 76%, turbidity reduced by 96%, and TSS reduced by 100% after combined treatment. Significantly all the parameters mentioned above met the effluent standards for reuse (<xref ref-type="fig" rid="F9">Figure&#x20;9</xref>). Color removal was achieved by up to 52%. The color of the effluent was 42 on the Pt-Co scale, which was not commensurate with reuse standards. Therefore, advanced oxidation processes, namely Ozonation, were employed for color removal to achieve the desired standard for reuse. It was observed that exposure of up to 2&#xa0;min at an Ozone dose of 5.5&#xa0;mg/L removed the color, which brought the effluent up to recommended reuse standards (CPHEEO, 2013); however, with an extended exposure time of 4&#xa0;min with an Ozone dose of 8.3&#xa0;mg/L, a color removal of up to 88% can be achieved, with a color concentration of less than 5&#xa0;Pt-Co unit, which is acceptable for water&#x20;reuse.</p>
<fig id="F9" position="float">
<label>FIGURE 9</label>
<caption>
<p>Effect of Coagulation &#x2b; UF and Ozone concentration on COD, BOD, TSS, Turbidity and Color.</p>
</caption>
<graphic xlink:href="fenvs-09-741343-g009.tif"/>
</fig>
<p>The coagulation combined with the ultra-filtration (UF) process is very efficient as a tertiary treatment process in reducing suspended particles, which ultimately results in reducing various physical parameters like TSS, turbidity, BOD, COD, and color to desired levels.</p>
</sec>
</sec>
<sec sec-type="conclusion" id="s4">
<title>Conclusion</title>
<p>The present study evaluated CETPs (designed and installed for non-potable reuse) in Northern India and examined the treatment of secondary effluent with combined coagulation followed by UF and Ozonation. The CETPs did not reclaim effluent for non-potable reuse, and a major fraction of treated effluent from all these CETPs was being discharged into surface water bodies followed by rivers. Half of the existing CETPs upgraded or changed their treatment scheme due to the enormous variation of industrial effluent, increasing organic load, and modifications to the manufacturing process of industries. The integrated efficiency of CETP at SIDCUL Haridwar was found to be the highest (80%), whereas the CETP at MIA Delhi had the lowest integrated efficiency of 51.8%. Multimedia and activated carbon filtration are not sufficient to treat secondary effluent for effluent reuse. A combination of coagulation and ultrafiltration followed by Ozonation as tertiary treatment is efficient for the treatment of secondary effluent. This process enables the effluent to meet reuse standards, reducing remaining impurities such as turbidity, suspended particles, COD, BOD, and color significantly.</p>
</sec>
</body>
<back>
<sec id="s5">
<title>Data Availability Statement</title>
<p>The original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding author.</p>
</sec>
<sec id="s6">
<title>Author Contributions</title>
<p>All authors listed have made a substantial, direct, and intellectual contribution to the work and approved it for publication.</p>
</sec>
<sec sec-type="COI-statement" id="s7">
<title>Conflict of Interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec sec-type="disclaimer" id="s8">
<title>Publisher&#x2019;s Note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors, and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ack>
<p>We also thank the CETP operators and plants for helping us undertake sampling and share CETP information.</p>
</ack>
<ref-list>
<title>References</title>
<ref id="B1">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Aziz</surname>
<given-names>H. A.</given-names>
</name>
<name>
<surname>Adlan</surname>
<given-names>M. N.</given-names>
</name>
<name>
<surname>Ariffin</surname>
<given-names>K. S.</given-names>
</name>
</person-group> (<year>2008</year>). <article-title>Heavy Metals (Cd, Pb, Zn, Ni, Cu and Cr(III)) Removal from Water in Malaysia: Post Treatment by High Quality limestone</article-title>. <source>Bioresour. Tech.</source> <volume>99</volume>, <fpage>1578</fpage>&#x2013;<lpage>1583</lpage>. <pub-id pub-id-type="doi">10.1016/j.biortech.2007.04.007</pub-id> </citation>
</ref>
<ref id="B2">
<citation citation-type="web">
<collab>Central Pollution Control Board (CPCB)</collab> (<year>2018</year>). <article-title>Assessment of Common Effluent Treatment Plants (CETPs) in the Industrial Clusters Comprising of Medium and Small Scale Industries</article-title>. <comment>Available at: <ext-link ext-link-type="uri" xlink:href="https://cpcb.nic.in/status-of-cetps/">https://cpcb.nic.in/status-of-cetps/</ext-link>
</comment>(<comment>Accessed 29 August 2018)</comment> </citation>
</ref>
<ref id="B4">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Colmenarejo</surname>
<given-names>M. F.</given-names>
</name>
<name>
<surname>Rubio</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>S&#xe1;nchez</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Vicente</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Garc&#xed;a</surname>
<given-names>M. G.</given-names>
</name>
<name>
<surname>Borja</surname>
<given-names>R.</given-names>
</name>
</person-group> (<year>2006</year>). <article-title>Evaluation of Municipal Wastewater Treatment Plants with Different Technologies at Las Rozas, Madrid (Spain)</article-title>. <source>J.&#x20;Environ. Manage.</source> <volume>81</volume> (<issue>4</issue>), <fpage>399</fpage>&#x2013;<lpage>404</lpage>. <pub-id pub-id-type="doi">10.1016/j.jenvman.2005.11.007</pub-id> </citation>
</ref>
<ref id="B5">
<citation citation-type="book">
<collab>CPHEEO</collab> (<year>2013</year>). &#x201C;<article-title>Manual on Sewerage and Sewage Treatment Systems - Part C: Management</article-title>,&#x201D; in <source>Chapter-3 Legal Framework and Policies</source>, <fpage>2</fpage>&#x2013;<lpage>15</lpage>. <comment>Available at <ext-link ext-link-type="uri" xlink:href="http://cpheeo.gov.in/upload/uploadfiles/files/systems_chapter2.pdf">http://cpheeo.gov.in/upload/uploadfiles/files/systems_chapter2.pdf</ext-link>
</comment>. </citation>
</ref>
<ref id="B6">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gerrity</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Pecson</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Trussell</surname>
<given-names>R. S.</given-names>
</name>
<name>
<surname>Trussell</surname>
<given-names>R. R.</given-names>
</name>
</person-group> (<year>2013</year>). <article-title>Potable Reuse Treatment Trains throughout the World</article-title>. <source>J.&#x20;Water Supply: Res. Technology-Aqua</source> <volume>62</volume> (<issue>6</issue>), <fpage>321</fpage>&#x2013;<lpage>338</lpage>. <pub-id pub-id-type="doi">10.2166/aqua.2013.041</pub-id> </citation>
</ref>
<ref id="B7">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ghumra</surname>
<given-names>D. P.</given-names>
</name>
<name>
<surname>Agarkoti</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Gogate</surname>
<given-names>P. R.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Improvements in Effluent Treatment Technologies in Common Effluent Treatment Plants (CETPs): Review and Recent Advances</article-title>. <source>Process Saf. Environ. Prot.</source> <volume>147</volume>, <fpage>1018</fpage>&#x2013;<lpage>1051</lpage>. <pub-id pub-id-type="doi">10.1016/j.psep.2021.01.021</pub-id> </citation>
</ref>
<ref id="B8">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gr&#xfc;ttner</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Winther-Nielsen</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>J&#xf8;rgensen</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>B&#xf8;gebjerg</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Sinkj&#xe6;r</surname>
<given-names>O.</given-names>
</name>
</person-group> (<year>1994</year>). <article-title>Inhibition of the Nitrification Process in Municipal Wastewater Treatment Plants by Industrial Discharges</article-title>. <source>Water Sci. Tech.</source> <volume>29</volume> (<issue>9</issue>), <fpage>69</fpage>&#x2013;<lpage>77</lpage>. <pub-id pub-id-type="doi">10.2166/wst.1994.0446</pub-id> </citation>
</ref>
<ref id="B9">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Harris-Lovett</surname>
<given-names>S. R.</given-names>
</name>
<name>
<surname>Binz</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Sedlak</surname>
<given-names>D. L.</given-names>
</name>
<name>
<surname>Kiparsky</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Truffer</surname>
<given-names>B.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>Beyond User Acceptance: A Legitimacy Framework for Potable Water Reuse in California</article-title>. <source>Environ. Sci. Technol.</source> <volume>49</volume> (<issue>13</issue>), <fpage>7552</fpage>&#x2013;<lpage>7561</lpage>. <pub-id pub-id-type="doi">10.1021/acs.est.5b00504</pub-id> </citation>
</ref>
<ref id="B10">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Jern</surname>
<given-names>N. W.</given-names>
</name>
</person-group> (<year>2006</year>). <source>Industrial Wastewater Treatment Technologies</source>. <edition>second edition</edition>. <publisher-loc>Shelton Street, Covent Garden London WC2H 9HE</publisher-loc>: <publisher-name>Imperial College Press</publisher-name>. </citation>
</ref>
<ref id="B11">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Metcalf</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Eddy</surname>
<given-names>C.</given-names>
</name>
</person-group> (<year>2003</year>). <source>Inc. Wastewater Engineering: Treatment and Resource Recovery</source>. <publisher-loc>Boston</publisher-loc>: <publisher-name>McGraw-Hill</publisher-name>. </citation>
</ref>
<ref id="B12">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Michael-Kordatou</surname>
<given-names>I.</given-names>
</name>
<name>
<surname>Michael</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Duan</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>He</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Dionysiou</surname>
<given-names>D. D.</given-names>
</name>
<name>
<surname>Mills</surname>
<given-names>M. A.</given-names>
</name>
<etal/>
</person-group> (<year>2015</year>). <article-title>Dissolved Effluent Organic Matter: Characteristics and Potential Implications in Wastewater Treatment and Reuse Applications</article-title>. <source>Water Res.</source> <volume>77</volume>, <fpage>213</fpage>&#x2013;<lpage>248</lpage>. <pub-id pub-id-type="doi">10.1016/j.watres.2015.03.011</pub-id> </citation>
</ref>
<ref id="B13">
<citation citation-type="web">
<collab>Ministry of Environment, Forest and Climate Change</collab> (<year>2016</year>). <article-title>Draft Notification on the Standards of Common Effluent Treatment Plants (CETP)</article-title>. <comment>Available at: <ext-link ext-link-type="uri" xlink:href="http://moef.gov.in/en/draft-notification-on-the-standards-of-common-effluent-treatment-plantscetps/">http://moef.gov.in/en/draft-notification-on-the-standards-of-common-effluent-treatment-plantscetps/</ext-link>
</comment>(<comment>Accessed 1 January 2016)</comment> </citation>
</ref>
<ref id="B14">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Padalkar</surname>
<given-names>A. V.</given-names>
</name>
<name>
<surname>Kaur</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Kumar</surname>
<given-names>R.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Performance Evaluation of Common Effluent Treatment Plant for Efficiency of Pollutant Removal and Relation to Design Adequacy</article-title>. <source>J.&#x20;Environ. Sci. Eng.</source> <volume>58</volume> (<issue>1</issue>), <fpage>17</fpage>&#x2013;<lpage>28</lpage>. </citation>
</ref>
<ref id="B15">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Padalkar</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Kaur</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Kumar</surname>
<given-names>R.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Reliability Analysis and Removal Efficiency Relationship of Common Effluent Treatment Plants of Industrial Clusters</article-title>. <source>Int. J.&#x20;Environ. Sci. Technol.</source> <volume>16</volume>, <fpage>1379</fpage>&#x2013;<lpage>1394</lpage>. <pub-id pub-id-type="doi">10.1007/s13762-018-1740-9</pub-id> </citation>
</ref>
<ref id="B16">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pathe</surname>
<given-names>P. P.</given-names>
</name>
<name>
<surname>Suresh Kumar</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Kharwade</surname>
<given-names>K. S. N.</given-names>
</name>
<name>
<surname>Kaul</surname>
<given-names>S. N.</given-names>
</name>
</person-group> (<year>2004</year>). <article-title>Common Effluent Treatment Plant (CEPT) for Wastewater Management from a Cluster of Small Scale Tanneries</article-title>. <source>Environ. Tech.</source> <volume>25</volume> (<issue>5</issue>), <fpage>555</fpage>&#x2013;<lpage>563</lpage>. <pub-id pub-id-type="doi">10.1080/09593332608618562c</pub-id> </citation>
</ref>
<ref id="B17">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Ranade</surname>
<given-names>V. V.</given-names>
</name>
<name>
<surname>Bhandari</surname>
<given-names>V. M.</given-names>
</name>
</person-group> (<year>2014</year>). <source>Industrial Wastewater Treatment, Recycling and Reuse</source>. <publisher-loc>The BoulevardOxford, OX5 1GB, UK</publisher-loc>: <publisher-name>Butterworth heinemannLangford Lane, Kidlington</publisher-name>. </citation>
</ref>
<ref id="B18">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Rice</surname>
<given-names>E. W.</given-names>
</name>
<name>
<surname>Baird</surname>
<given-names>R. D.</given-names>
</name>
<name>
<surname>Eaton</surname>
<given-names>A. D.</given-names>
</name>
</person-group> (<year>2012</year>). <source>Standard Methods for Examination of Water and wastewater</source>. <publisher-loc>Wasinton DC</publisher-loc>. <publisher-name>Publisher American Public Health Association (APHA), American Water Works Association (AWWA), Water Environment Federetion WEF</publisher-name>. <pub-id pub-id-type="doi">10.5209/rev_ANHM.2012.v5.n2.40440</pub-id> </citation>
</ref>
<ref id="B19">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Visvanathan</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Asano</surname>
<given-names>T.</given-names>
</name>
</person-group> (<year>2014</year>). &#x201C;<article-title>The Potential For Industrial Wastewater Reuse</article-title>,&#x201D; in <source>Encyclopaedia of Life Support Systems (EOLSS)</source> <volume>1</volume>, <fpage>1</fpage>&#x2013;<lpage>19</lpage>. <comment>Available at: <ext-link ext-link-type="uri" xlink:href="http://www.eolss.net/Eolss-sampleAllChapter.aspx">http://www.eolss.net/Eolss-sampleAllChapter.aspx</ext-link>
</comment>. </citation>
</ref>
<ref id="B20">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Vyas</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Modhera</surname>
<given-names>K. B.</given-names>
</name>
<name>
<surname>Vyas</surname>
<given-names>V.</given-names>
</name>
<name>
<surname>Sharma</surname>
<given-names>A.</given-names>
</name>
</person-group> (<year>2011</year>). <article-title>Performance Forecasting of Common Effluent Treatment Plant Parameters by Artificial Neural Network</article-title>. <source>ARPN J.&#x20;Eng. Appl. Sci.</source> <volume>6</volume>, <fpage>1</fpage>. </citation>
</ref>
<ref id="B21">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Warsinger</surname>
<given-names>D. M.</given-names>
</name>
<name>
<surname>Chakraborty</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Tow</surname>
<given-names>E. W.</given-names>
</name>
<name>
<surname>Plumlee</surname>
<given-names>M. H.</given-names>
</name>
<name>
<surname>Bellona</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Loutatidou</surname>
<given-names>S.</given-names>
</name>
<etal/>
</person-group> (<year>2018</year>). <article-title>A Review of Polymeric Membranes and Processes for Potable Water Reuse</article-title>. <source>Prog. Polym. Sci.</source> <volume>1081</volume>, <fpage>209</fpage>&#x2013;<lpage>237</lpage>. <pub-id pub-id-type="doi">10.1016/j.progpolymsci.2018.01.004</pub-id> </citation>
</ref>
</ref-list>
</back>
</article>