<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Archiving and Interchange DTD v2.3 20070202//EN" "archivearticle.dtd">
<article article-type="methods-article" dtd-version="2.3" xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Energy Res.</journal-id>
<journal-title>Frontiers in Energy Research</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Energy Res.</abbrev-journal-title>
<issn pub-type="epub">2296-598X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">1230743</article-id>
<article-id pub-id-type="doi">10.3389/fenrg.2023.1230743</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Energy Research</subject>
<subj-group>
<subject>Methods</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>MEA-based CO<sub>2</sub> capture: a study focuses on MEA concentrations and process parameters</article-title>
<alt-title alt-title-type="left-running-head">Wang et al.</alt-title>
<alt-title alt-title-type="right-running-head">
<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3389/fenrg.2023.1230743">10.3389/fenrg.2023.1230743</ext-link>
</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Wang</surname>
<given-names>Nan</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
<uri xlink:href="https://loop.frontiersin.org/people/2309829/overview"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Wang</surname>
<given-names>Dong</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Krook-Riekkola</surname>
<given-names>Anna</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Ji</surname>
<given-names>Xiaoyan</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
<uri xlink:href="https://loop.frontiersin.org/people/167749/overview"/>
</contrib>
</contrib-group>
<aff id="aff1">
<sup>1</sup>
<institution>Energy Engineering</institution>, <institution>Department of Engineering Science and Mathematics</institution>, <institution>Lule&#xe5; University of Technology</institution>, <addr-line>Lule&#xe5;</addr-line>, <country>Sweden</country>
</aff>
<aff id="aff2">
<sup>2</sup>
<institution>Sinopec Nanjing Chemical Research Institute</institution>, <addr-line>Nanjing</addr-line>, <country>China</country>
</aff>
<author-notes>
<fn fn-type="edited-by">
<p>
<bold>Edited by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/536686/overview">Munish Kumar Chandel</ext-link>, Indian Institute of Technology Bombay, India</p>
</fn>
<fn fn-type="edited-by">
<p>
<bold>Reviewed by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/824244/overview">Yukun Hu</ext-link>, University College London, United Kingdom</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/195592/overview">Joan Ram&#xf3;n Morante</ext-link>, Energy Research Institute of Catalonia (IREC), Spain</p>
</fn>
<corresp id="c001">&#x2a;Correspondence: Nan Wang, <email>nan.wang@ltu.se</email>; Xiaoyan Ji, <email>xiaoyan.ji@ltu.se</email>
</corresp>
</author-notes>
<pub-date pub-type="epub">
<day>15</day>
<month>09</month>
<year>2023</year>
</pub-date>
<pub-date pub-type="collection">
<year>2023</year>
</pub-date>
<volume>11</volume>
<elocation-id>1230743</elocation-id>
<history>
<date date-type="received">
<day>29</day>
<month>05</month>
<year>2023</year>
</date>
<date date-type="accepted">
<day>04</day>
<month>09</month>
<year>2023</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2023 Wang, Wang, Krook-Riekkola and Ji.</copyright-statement>
<copyright-year>2023</copyright-year>
<copyright-holder>Wang, Wang, Krook-Riekkola and Ji</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<p>CO<sub>2</sub> capture using monoethanolamine (MEA) is one of the important decarbonization options and often considered as a benchmark, while the optimal MEA contraction and systematic process study are still lacking. In this work, firstly, the MEA concentrations between 15 and 30&#xa0;wt% were studied from both process simulations with Aspen Plus and experimental measurements in the pilot-scale. 20&#xa0;wt% MEA was identified as the preferable solution. Subsequently, a systematic analysis was conducted for CO<sub>2</sub> capture using 20&#xa0;wt% MEA with/without CO<sub>2</sub> compression to study how various parameters, including gas flow rate, CO<sub>2</sub> concentration, and CO<sub>2</sub> removal rate, affected the energy demand and techno-economic performances quantitatively. The influence of each parameter on both energy demand and cost showed an obvious non-linear relationship, evidencing the importance of systematic analysis for further study on decarbonization. The evaluation indicated that the regeneration heat required the largest portion of energy demand. The economic analysis showed that the capital cost was more sensitive to the selected parameters than the operational cost, while the operational cost created a major change in the overall cost. In addition, the gas flow rate and CO<sub>2</sub> concentration were the main parameters affecting the cost, rather than the CO<sub>2</sub> removal rate. Finally, it was suggested that, for a new plant, CO<sub>2</sub> capture showed the minimum investment cost per ton CO<sub>2</sub> when operating the plant on a large scale, high CO<sub>2</sub> concentration, and high CO<sub>2</sub> removal rate; for an existing plant, the capture preferred to run with the high CO<sub>2</sub> removal rate.</p>
</abstract>
<kwd-group>
<kwd>CO<sub>2</sub> capture</kwd>
<kwd>MEA</kwd>
<kwd>process simulation</kwd>
<kwd>solvent concentration</kwd>
<kwd>process parameters</kwd>
</kwd-group>
<custom-meta-wrap>
<custom-meta>
<meta-name>section-at-acceptance</meta-name>
<meta-value>Carbon Capture, Utilization and Storage</meta-value>
</custom-meta>
</custom-meta-wrap>
</article-meta>
</front>
<body>
<sec id="s1">
<title>1 Introduction</title>
<p>Anthropogenic emission of CO<sub>2</sub> is one of the main causes of global warming. According to the Intergovernmental Panel on Climate Change (IPCC), global anthropogenic emissions of CO<sub>2</sub> should be reduced to net-zero by 2050 to avoid a temperature increase of greater than 1.5&#xb0;C (<xref ref-type="bibr" rid="B32">Masson-Delmotte et al., 2018</xref>). The main sources of CO<sub>2</sub> emissions are the combustion of fossil fuels and industrial processes, such as the cement industry. To mitigate CO<sub>2</sub> emissions, different decarbonization options have been proposed, such as improving energy efficiency, using hydrogen-based energy, replacing fossil fuels with biomass, combining with carbon capture and storage (CCS) processes, etc. Among all these options, the CCS with novel CO<sub>2</sub> capture, such as membrane, adsorption with zeolites, absorption with new solvents like ionic liquids, are promising for deployment in the future, but restricted by the low technology readiness level (TRL) in the current. Among the CCS technologies, chemical absorption is the most mature one with the advantages of high stability, capacity, and TRL, and specifically, monoethanolamine (MEA) is the most used solvent in numerous processes because of its excellent capture performance (<xref ref-type="bibr" rid="B26">Li et al., 2013</xref>). It is of importance to evaluate the most technology-ready MEA-based CO<sub>2</sub> capture process as detailed as possible in case of urgent deployment of CO<sub>2</sub> mitigation in a short-term period. Besides, in the long-term period, a solid conclusion of the MEA-based CO<sub>2</sub> capture process is necessary to function as the reference for evaluating the newly developed advanced technologies.</p>
<p>Many researchers were focusing on the MEA-based CO<sub>2</sub> capture in coal-fired and gas-fired power plants owing to its largest share of anthropogenic CO<sub>2</sub> emissions, the effect of the CO<sub>2</sub> capture process on the overall plant efficiency and electricity price has been studied, and efforts have been made in order to compensate the plant efficiency as well (<xref ref-type="bibr" rid="B1">Abu-Zahra et al., 2007a</xref>; <xref ref-type="bibr" rid="B9">Dave et al., 2011</xref>; <xref ref-type="bibr" rid="B10">Duan et al., 2012</xref>; <xref ref-type="bibr" rid="B19">Gupta et al., 2015</xref>). Later, the research effort was shifted to other industrial sectors, as industrial emissions were considered as another important CO<sub>2</sub> source. On the one hand, techno-economic analyses and comparisons have been conducted to assess the feasibility of the MEA-based CO<sub>2</sub> capture process in the iron and steel sector and aluminum production (<xref ref-type="bibr" rid="B20">Hassan et al., 2007</xref>; <xref ref-type="bibr" rid="B33">Mathisen et al., 2013</xref>; <xref ref-type="bibr" rid="B34">Mathisen et al., 2014</xref>; <xref ref-type="bibr" rid="B41">Sundqvist et al., 2018</xref>; <xref ref-type="bibr" rid="B31">Liu et al., 2019</xref>). Another study evaluated the performance of different amine(s)-based solvents at comparably higher CO<sub>2</sub> concentrations (<xref ref-type="bibr" rid="B25">Laribi et al., 2019</xref>). A configuration study compared various options and proposed ones to further reduce the energy demand of the capture process (<xref ref-type="bibr" rid="B11">Dubois and Thomas, 2018</xref>). On the other hand, some researchers have devoted themselves to combining the experimental data with various models and improving the existing capture processes, in order to reduce the investment from research and development to the plant operation (<xref ref-type="bibr" rid="B1">Abu-Zahra et al., 2007a</xref>; <xref ref-type="bibr" rid="B27">Li et al., 2014</xref>; <xref ref-type="bibr" rid="B28">Li et al., 2016a</xref>; <xref ref-type="bibr" rid="B16">Garcia et al., 2017</xref>; <xref ref-type="bibr" rid="B35">Moioli and Pellegrini, 2019</xref>).</p>
<p>Most of the research mentioned above uses the 30&#xa0;wt% aqueous MEA solutions as the reference case, i.e., 30&#xa0;wt% aqueous MEA as the optimal concentration compromised between capture performance and MEA degradation and corrosion. The results from the pilot plant study conducted by Notz et al. also suggested 30&#xa0;wt% MEA (<xref ref-type="bibr" rid="B37">Notz et al., 2012</xref>). While others indicate that the selection of MEA concentration needs to be carefully considered with other parameters, such as CO<sub>2</sub> concentration (<xref ref-type="bibr" rid="B17">Gardarsdottir et al., 2015</xref>). Arachchige and Melaaen studied the effects of MEA concentration on the removal efficiency and concluded that 22&#x2013;25&#xa0;wt% MEA concentration as the optimal region for maximizing the removal efficiency (<xref ref-type="bibr" rid="B3">Arachchige and Melaaen, 2012</xref>), while others suggested even higher than 30&#xa0;wt% MEA (<xref ref-type="bibr" rid="B2">Abu-Zahra et al., 2007b</xref>; <xref ref-type="bibr" rid="B29">Li et al., 2016b</xref>). Besides, a rapid corrosion rate was observed when using 30&#xa0;wt% MEA, and prone degradation in the high MEA concentration was also mentioned by Wagner (<xref ref-type="bibr" rid="B43">Wagner, 2006</xref>). Replacing carbon steel with stainless steel 316L can only partially moderate the corrosion issue (<xref ref-type="bibr" rid="B15">Fytianos et al., 2016</xref>). Additionally, it has been pointed out that 30&#xa0;wt% MEA can lead to other problems, such as thermal and oxidative degradation, as well as high bulge temperature. However, to the best of our knowledge, no clear and universal conclusion has been drawn regarding the selection of MEA concentration, and the concentration study, especially lower than 30&#xa0;wt%, is limited and needs to be fulfilled. Another information shortage is that the gas from different industries differs in CO<sub>2</sub> concentration, gas flow rate and other conditions, and the CO<sub>2</sub> removal rate can be adjusted significantly (<xref ref-type="bibr" rid="B18">Gar&#x111;arsd&#xf3;ttir et al., 2015</xref>; <xref ref-type="bibr" rid="B36">Nguyen and Zondervan, 2018</xref>). All the mentioned scenarios may have significant impacts on the selection of optimal MEA concentration when different industries and plants are interested. It is worthy to note that, in many of the research, only the energy demand was used as the key performance indicator for the MEA concentration selection, even though the investment presents a straightforward way of demonstrating how the MEA concentration influences the overall economics in the plant level.</p>
<p>This work is to analyze the effect of MEA concentrations (15&#x2013;30&#xa0;wt%) on the performance of the MEA-based CO<sub>2</sub> capture process and identify the optimal concentration of MEA on different operation conditions via Aspen Plus simulation. Experimental data of 30&#xa0;wt% MEA from the literature and new pilot experiments with 20&#xa0;wt% MEA were provided for model validation. Finally, the energy demands and CAPEX/OPEX of the capture plant were predicted under various CO<sub>2</sub> concentrations, gas flow rates, and removal rates.</p>
</sec>
<sec id="s2">
<title>2 Methodologies</title>
<p>In this work, pilot-scale experiments were carried out for CO<sub>2</sub> capture with 20&#xa0;wt% MEA, as the previous results on the pilot-scale testing were only available for 30&#xa0;wt% MEA. The experimental set-up and procedures were described in this section. The systematic investigation of CO<sub>2</sub> capture was mainly based on process simulations with the commercial software Aspen Plus, the process and the corresponding specifications were described briefly, and the methods for estimating energy demand and cost were summarized.</p>
<sec id="s2-1">
<title>2.1 Pilot experimental testing</title>
<sec id="s2-1-1">
<title>2.1.1 Chemicals and materials</title>
<p>In experiments, the inlet gas containing 12.5 Vol % CO<sub>2</sub> was prepared. The gas preparation started with the pressure release from the CO<sub>2</sub> gas cylinder (99.9% purity provided by Nanjing special gases Co., Ltd.) to the gas reservoir, and the CO<sub>2</sub> was blown into the gas buffer tank, in which the flow rate of CO<sub>2</sub> was controlled by the pressure relief valve and flowmeter. Air was blown directly from the atmosphere. The air and CO<sub>2</sub> were well mixed and then fed into the absorber at a certain flow rate. The gas composition, temperature, and pressure were measured by Kane KM9106E combustion analyzer (Keison, UK). The 20&#xa0;wt% aqueous MEA solution was prepared by mixing MEA (Jiaxing Jinyan Chemical Co., Ltd.) and deionized water.</p>
</sec>
<sec id="s2-1-2">
<title>2.1.2 Experimental set-up and specifications</title>
<p>The experimental set-up used for pilot-testing is depicted in <xref ref-type="fig" rid="F1">Figure 1</xref>. Two thermometers (Kangle Instruments Co., Ltd.) were equipped at the top and bottom of absorber and desorber, respectively, to measure the temperature of columns. Similarly, two pressure gauges (XueHu Special Instrument Technology Co., Ltd.) were equipped at the top and bottom of absorber and desorber, respectively, to record the column pressure. The specifications are listed in <xref ref-type="table" rid="T1">Table 1</xref>. In the absorption-desorption process, CO<sub>2</sub> in the gas stream was absorbed by the 20&#xa0;wt% MEA solution, and then the CO<sub>2</sub>-rich solvent was preheated by a rich-lean heat exchanger (HEX) and sent to the regeneration column. The regenerated CO<sub>2</sub> gas stream was condensed in a condenser to separate water and obtain a 99% CO<sub>2</sub> product. The CO<sub>2</sub>-lean solvent from the reboiler was pumped to the rich-lean heat exchanger to recover the heat. The CO<sub>2</sub>-lean solvent stream was further cooled and then recirculated to the absorber with a solvent makeup stream to compensate for the solvent loss.</p>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption>
<p>Schematic flow diagram of the pilot test with 20&#xa0;wt% MEA solution.</p>
</caption>
<graphic xlink:href="fenrg-11-1230743-g001.tif"/>
</fig>
<table-wrap id="T1" position="float">
<label>TABLE 1</label>
<caption>
<p>Experimental specifications of 20&#xa0;wt% MEA-based CO<sub>2</sub> capture process.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="center">Specifications</th>
<th align="center">Measured value</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="center">Absorber</td>
<td align="left"/>
</tr>
<tr>
<td align="center">Packing type</td>
<td align="center">Pall ring</td>
</tr>
<tr>
<td align="center">Packing height, m</td>
<td align="center">3.6</td>
</tr>
<tr>
<td align="center">Bottom section pressure, kPaG</td>
<td align="center">6</td>
</tr>
<tr>
<td align="center">Top section pressure, kPaG</td>
<td align="center">2</td>
</tr>
<tr>
<td align="center">Gas and liquid inlet temperature, K</td>
<td align="center">313.15</td>
</tr>
<tr>
<td align="center">Desorber</td>
<td align="left"/>
</tr>
<tr>
<td align="center">Packing type</td>
<td align="center">Pall ring</td>
</tr>
<tr>
<td align="center">Packing height, m</td>
<td align="center">3.6</td>
</tr>
<tr>
<td align="center">Bottom section pressure, kPaG</td>
<td align="center">50</td>
</tr>
<tr>
<td align="center">Top section pressure, kPaG</td>
<td align="center">30</td>
</tr>
<tr>
<td align="center">Gas stream flow rate</td>
<td align="center">3.43 Nm<sup>3</sup>/h</td>
</tr>
<tr>
<td align="center">Lean loading</td>
<td align="center">13.7&#xa0;L <sub>CO2</sub>/L <sub>solvent</sub>
</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
</sec>
<sec id="s2-2">
<title>2.2 Process and simulation</title>
<sec id="s2-2-1">
<title>2.2.1 Process description</title>
<p>In simulations, the MEA-based capture process combined with a CO<sub>2</sub> compression unit is shown in <xref ref-type="fig" rid="F2">Figure 2</xref>. The inlet gas travels through a pretreatment unit to cool the gas and reduce the water content. The treated gas is then fed into the absorber, where CO<sub>2</sub> is reactively absorbed by the MEA solvent. The CO<sub>2</sub>-rich solvent exiting the absorber is pumped into the internal heat exchanger, where the CO<sub>2</sub>-rich solvent is preheated and fed into the regeneration column. The CO<sub>2</sub> exiting from the top of the regeneration column then flows into a series of compression units to reach a specific condition for transportation, storage, or utilization. The makeup streams, which contain water and MEA, are added into the recycle stream.</p>
<fig id="F2" position="float">
<label>FIGURE 2</label>
<caption>
<p>Schematic diagram of the MEA-based CO<sub>2</sub> capture process in Aspen Plus.</p>
</caption>
<graphic xlink:href="fenrg-11-1230743-g002.tif"/>
</fig>
</sec>
<sec id="s2-2-2">
<title>2.2.2 Process specifications</title>
<p>The inlet gas may contain O<sub>2</sub>, CO<sub>2</sub>, H<sub>2</sub>O, N<sub>2</sub>, CO, H<sub>2</sub>, and several trace components, such as NO<sub>x</sub> and SO<sub>x</sub>. However, to simplify the process, only O<sub>2</sub>, CO<sub>2</sub>, H<sub>2</sub>O, and N<sub>2</sub> were considered, and the gas was assumed to contain 2.4&#xa0;wt% O<sub>2</sub>, 4.2&#xa0;wt% H<sub>2</sub>O, and balanced CO<sub>2</sub> and N<sub>2</sub> concentrations.</p>
<p>In this study, two gas flow rates were assumed, and the large flow rate was 252.7 ton/hr (i.e., 70.2&#xa0;kg/s), corresponding to the full capacity of the St. Marys cement plant (<xref ref-type="bibr" rid="B21">Hassan, 2005</xref>). The medium gas flow rate was half the large flow rate, representing the capacity of a medium-sized plant. The CO<sub>2</sub> concentration of 31.8&#xa0;wt% is the original data from the St. Marys cement plant, and then the CO<sub>2</sub> concentration was further expanded to a range of 10&#x2013;50&#xa0;wt% for generalizing the study. The CO<sub>2</sub> removal rate was defined as the ratio between the amount of CO<sub>2</sub> captured in the process and the total amount of CO<sub>2</sub> entered the process. It was set between 65% and 95% to investigate its influence on the energy demand and economy (cost), and values lower than 65% were not included owing to the CO<sub>2</sub> capture requirement. These parameters are listed in <xref ref-type="table" rid="T2">Table 2</xref>. Based on these parameters, 60 cases of various CO<sub>2</sub> removal rates, gas flow rates, and CO<sub>2</sub> concentrations were created for process simulation. Other process parameters are listed in <xref ref-type="table" rid="T3">Table 3</xref>.</p>
<table-wrap id="T2" position="float">
<label>TABLE 2</label>
<caption>
<p>Input parameters in the process simulation.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="center">Input parameters</th>
<th align="center">Values</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="center">CO<sub>2</sub> concentration</td>
<td align="center">10%, 20%, 31.8%, 40%, 50% (wt%)</td>
</tr>
<tr>
<td align="center">CO<sub>2</sub> removal rate</td>
<td align="center">65%, 75%, 85%, 95% (mol%)</td>
</tr>
<tr>
<td rowspan="2" align="center">Gas flow rate</td>
<td align="center">252.7 ton/hr (large scale, &#x201c;LF&#x201d;)</td>
</tr>
<tr>
<td align="center">126.4 ton/hr (medium scale, &#x201c;MF&#x201d;)</td>
</tr>
</tbody>
</table>
</table-wrap>
<table-wrap id="T3" position="float">
<label>TABLE 3</label>
<caption>
<p>Initial specifications in the MEA-based CO<sub>2</sub> capture process.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="center">Specifications</th>
<th align="center">Value</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="center">Absorber</td>
<td align="left"/>
</tr>
<tr>
<td align="center">Packing type</td>
<td align="center">IMTP 1.5-IN NORTON</td>
</tr>
<tr>
<td align="center">Number of stages</td>
<td align="center">20</td>
</tr>
<tr>
<td align="center">Top section pressure</td>
<td align="center">1.2&#xa0;bar</td>
</tr>
<tr>
<td align="center">Desorber</td>
<td align="left"/>
</tr>
<tr>
<td align="center">Packing type</td>
<td align="center">IMTP 1.5-IN NORTON</td>
</tr>
<tr>
<td align="center">Number of stages</td>
<td align="center">12</td>
</tr>
<tr>
<td align="center">Top section pressure</td>
<td align="center">2.1&#xa0;bar</td>
</tr>
<tr>
<td align="center">Inlet MEA temperature</td>
<td align="center">313.15&#xa0;K</td>
</tr>
<tr>
<td align="center">Lean loading</td>
<td align="center">0.3&#xa0;mol<sub>CO2</sub>/mol<sub>MEA</sub>
</td>
</tr>
<tr>
<td align="center">Gas condition</td>
<td align="center">433.15&#xa0;K, at atmospheric pressure</td>
</tr>
<tr>
<td align="center">Compressed CO<sub>2</sub> condition</td>
<td align="center">303.15&#xa0;K&#xa0;C, 150&#xa0;bar</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
<sec id="s2-2-3">
<title>2.2.3 Simulation specifications</title>
<p>The process development strategy follows the same principle as the study by <xref ref-type="bibr" rid="B38">Penteado et al. (2016</xref>). Both columns were designed with the equilibrium model and then switched to the rate-based model that simultaneously described the mass and heat transfer rate phenomena with equilibrium and kinetic controlled reactions. A design specification was set in the absorber to reach a certain capture target by varying the lean MEA flow rate. The other two design specifications were configured in the desorber: one matched the lean CO<sub>2</sub> loading of 0.3 mol<sub>CO2</sub>/mol<sub>MEA</sub> by varying the reboiler duty, and the other ensured that the gas stream exiting the desorber reached 98&#xa0;mol% CO<sub>2</sub> purity by changing the distillate flow rate. The heights for both columns were determined by sensitivity analyses, where the required lean MEA flow rate in the absorber and the minimum reboiler duty in the desorber were calculated.</p>
<p>The recycle stream should be closed in the process simulation to achieve process stability and simulation convergence. However, closing the recycle stream by a blocked connection increases the computing time and could create convergence problems. In addition, the labor becomes more complex when adjusting the operating conditions. Thus, in this study, the method described by Penteado et al. was used to improve the stability and usability of the simulation, i.e., instead of connecting the lean MEA recycle stream with the absorber inlet, a transfer block was used to virtually close the recycle. This was performed using two steps. 1) The design specifications were used to fix the lean loading of the bottom stream from desorber, and 2) a balance block was created to control the flow rates of the makeup streams. These two steps ensured that the recycle stream and lean MEA stream were nearly identical in composition and flow rate. The initial specifications of the process are listed in <xref ref-type="table" rid="T3">Table 3</xref>. It is worth noting that IMTP 1.5-IN NORTON was chosen in this work because of the following reasons: 1) the surface area of this type of packing is available in the database, and 2) a similar IMTP packing was used in the pilot plant, where the data was used for the validation of process simulation. The comparison with the experimental data using a similar packing will increase the reliability of holdup calculation, leading to credible results.</p>
<p>The simulation results depend on the accuracy of the properties, phase equilibria, mass and heat transfer, and reaction kinetics. Proper models were chosen to calculate the required thermodynamic properties (enthalpy, entropy, Gibbs free energy, and volume) and transport properties (viscosity, thermal conductivity, diffusion coefficient, and surface tension) in the liquid and vapor phases. The thermodynamic and transport properties were extracted from the Aspen Plus database and configured in the component specifications.</p>
<p>The electrolyte non-random two liquid model was used to describe the non-ideal behaviors of the liquid phase, and the Redlich-Kwong equation of state was chosen for the vapor phase to describe the phase equilibria (<xref ref-type="bibr" rid="B30">Liu et al., 1999</xref>; <xref ref-type="bibr" rid="B45">Zhang et al., 2009</xref>; <xref ref-type="bibr" rid="B44">Zhang and Chen, 2010</xref>). Both models have been implemented in Aspen Plus and verified for MEA-based technologies for CO<sub>2</sub> capture (<xref ref-type="bibr" rid="B8">Chalmers and Gibbins, 2007</xref>; <xref ref-type="bibr" rid="B42">Thiele et al., 2007</xref>; <xref ref-type="bibr" rid="B22">Hi et al., 2015</xref>). The parameters (pure, binary, and electrolyte-pair) for all the components were maintained as default values, as this simulation was conducted based on the example file used for the MEA-CO<sub>2</sub> system.</p>
<p>The widely used reaction mechanism described by <xref ref-type="bibr" rid="B14">Freguia and Rochelle (2003</xref>) with three equilibrium reactions and two reversible kinetically controlled reactions was adopted, and the corresponding parameters were obtained from <xref ref-type="bibr" rid="B5">Austgen et al. (1989</xref>), <xref ref-type="bibr" rid="B39">Pinsent et al. (1956</xref>), and <xref ref-type="bibr" rid="B23">Hikita et al. (1977</xref>). The reactions and corresponding kinetic parameters are listed in the <xref ref-type="sec" rid="s10">Supplementary Table SA</xref>).</p>
<p>For the mass and heat transfer calculations, the Onda-68 correlation was selected for the mass transfer coefficient and interfacial area. The Chilton and Colburn correlation was applied to obtain the heat transfer coefficient, and the packing holdups were calculated using the approach by <xref ref-type="bibr" rid="B7">Bravo et al. (1992</xref>).</p>
</sec>
</sec>
<sec id="s2-3">
<title>2.3 Energy demand and economic analyses</title>
<p>The energy calculation in this study consisted of two scenarios: the energy demand of the process with and without a compression unit. Energy demands in the MEA-based CO<sub>2</sub> capture process are: 1) the heating duty of the reboiler for solvent regeneration and the heaters; 2) the electric power required for the blower, pumps, and CO<sub>2</sub> compressor; and 3) the cooling duty of the condenser for solvent regeneration and the coolers. The energy demand mentioned above was estimated in energy power and then converted into cost with the energy prices listed in <xref ref-type="table" rid="T4">Table 4</xref> for discussion and comparison.</p>
<table-wrap id="T4" position="float">
<label>TABLE 4</label>
<caption>
<p>Utilities and solvent prices.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="center">Energy and solvent</th>
<th align="center">Cost</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="center">Steam, $/GJ</td>
<td align="center">6.00</td>
</tr>
<tr>
<td align="center">Cooling water, $/GJ</td>
<td align="center">0.35</td>
</tr>
<tr>
<td align="center">Electricity, $/kWh</td>
<td align="center">0.10</td>
</tr>
<tr>
<td align="center">Refrigeration, $/GJ</td>
<td align="center">4.00</td>
</tr>
<tr>
<td align="center">MEA, $/kg</td>
<td align="center">1.32</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>An economic analysis was conducted with the Aspen Process Economic Analyzer (APEA) based on the industry-standard Icarus System (<xref ref-type="bibr" rid="B4">Aspen, 2010</xref>). <xref ref-type="fig" rid="F3">Figure 3</xref> shows the procedures of economic analysis in the APEA. The APEA is an equipment-based approach to estimate the economy. It maps and sizes the equipment to create a volumetric model, which is used to estimate the total installed cost. With other input parameters used in the APEA, the template defines the equipment-based parameters required in the analysis. It also defines the currencies and interest rates for the cost calculation, and the investment options offer the plant life setting and operating hours that could be used for quantitatively calculating the operational cost. The stream and utility prices assist the material and energy cost processes. With this information, the cost can be evaluated and generated (e.g., equipment and utilities).</p>
<fig id="F3" position="float">
<label>FIGURE 3</label>
<caption>
<p>The liquid temperature profiles as simulation outputs and pilot plant experimental data. <bold>(A)</bold> absorber and <bold>(B)</bold> desorber of the pilot plant at the University of Texas at Austin, <bold>(C)</bold> absorber and <bold>(D)</bold> desorber of the pilot plant at the University of Kaiserslautern.</p>
</caption>
<graphic xlink:href="fenrg-11-1230743-g003.tif"/>
</fig>
<p>The annualized total cost (ATC) was calculated as a sum of the operational cost (OPEX) and capital investment cost (CAPEX). ATC was estimated using Eq. <xref ref-type="disp-formula" rid="e1">1</xref>.<disp-formula id="e1">
<mml:math id="m1">
<mml:mrow>
<mml:mi>A</mml:mi>
<mml:mi>T</mml:mi>
<mml:mi>C</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mi>O</mml:mi>
<mml:mi>P</mml:mi>
<mml:mi>E</mml:mi>
<mml:mi>X</mml:mi>
<mml:mo>&#x2b;</mml:mo>
<mml:mi>C</mml:mi>
<mml:mi>A</mml:mi>
<mml:mi>P</mml:mi>
<mml:mi>E</mml:mi>
<mml:mi>X</mml:mi>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="|">
<mml:mrow>
<mml:mfrac>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:msup>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="|">
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mo>&#x2b;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mi>N</mml:mi>
</mml:msup>
</mml:mrow>
<mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="|">
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mo>&#x2b;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mi>N</mml:mi>
</mml:msup>
<mml:mo>&#x2212;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mrow>
<mml:msub>
<mml:mi>M</mml:mi>
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mi>C</mml:mi>
<mml:mi>O</mml:mi>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msub>
<mml:mi>t</mml:mi>
<mml:mi>o</mml:mi>
<mml:mi>t</mml:mi>
<mml:mi>a</mml:mi>
<mml:mi>l</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mfrac>
</mml:mrow>
</mml:math>
<label>(1)</label>
</disp-formula>where CAPEX is the total cost of the plant, which consists of the direct and indirect costs, i.e., the total installed cost, contracts, contingencies, overheads, and other costs; OPEX is the summation cost of the raw material, utility, operating labor, maintenance, operating charges, plant overhead, and general and administrative cost; <italic>i</italic> is the interest rate, and <italic>N</italic> is the operating life of the plant. In this study, <italic>i</italic> was set to 10%; <italic>N</italic> was set to 25 years, and the plant operating time was assumed to be 8,700&#xa0;h per year (<xref ref-type="bibr" rid="B6">Biegler et al., 1997</xref>). Other parameters used for the CAPEX and OPEX calculations were set to the default values. <xref ref-type="table" rid="T4">Table 4</xref> lists the utilities and solvent prices used in the OPEX calculation (<xref ref-type="bibr" rid="B13">Eurostat, 2016</xref>; <xref ref-type="bibr" rid="B24">Jakobsen et al., 2017</xref>).</p>
</sec>
</sec>
<sec sec-type="results|discussion" id="s3">
<title>3 Results and discussion</title>
<p>In this study, pilot-testing was conducted, proving new experimental results. The process was configurated in Aspen Plus with the initial specifications listed in <xref ref-type="table" rid="T3">Table 3</xref>, and the simulation was validated with the practical data using both 20 and 30&#xa0;wt% MEA solvent. Then the effect of MEA concentrations on the process performance was investigated, and optimal MEA concentration was determined. Afterward, a systematic study was conducted based on process simulation, where the effects of MEA concentration, along with selected parameters, on the energy and cost results were analyzed individually and interactively.</p>
<sec id="s3-1">
<title>3.1 Experimental results and simulation validations</title>
<sec id="s3-1-1">
<title>3.1.1 New experimental results for 20&#xa0;wt% aqueous MEA and the corresponding model validation</title>
<p>Using the experimental set-up described in <xref ref-type="fig" rid="F1">Figure 1</xref>, the key experimental results of CO<sub>2</sub> capture, i.e., CO<sub>2</sub> removal rate, desorber bottom section temperature, and gas-to-liquid ratio, with 20&#xa0;wt% MEA are listed in <xref ref-type="table" rid="T5">Table 5</xref>. This is the first time to report the data with 20&#xa0;wt% MEA, and no comparison with other available data can be conducted.</p>
<table-wrap id="T5" position="float">
<label>TABLE 5</label>
<caption>
<p>Key experimental and simulation results for validation of 20&#xa0;wt% MEA solvent.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="center">Variable</th>
<th align="center">Measurements</th>
<th align="center">Simulation output</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="center">CO<sub>2</sub> removal, %</td>
<td align="center">80</td>
<td align="center">77.6</td>
</tr>
<tr>
<td align="center">Reboiler heat duty, kcal/hr</td>
<td align="center">1050</td>
<td align="center">793.649</td>
</tr>
<tr>
<td align="center">Desorber bottom section temperature, K</td>
<td align="center">373.15&#x2013;375.15</td>
<td align="center">378.15&#x2013;386.15</td>
</tr>
<tr>
<td align="center">Gas to liquid ratio, Nm<sup>3</sup>/m<sup>3</sup>
</td>
<td align="center">286</td>
<td align="center">311</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>The newly determined experimental results were used to validate the process simulation results, where the simulations were performed under the same conditions used at the real pilot plants. As shown in <xref ref-type="table" rid="T5">Table 5</xref>, a comparable simulation output proved a reliable process model in our study with 20&#xa0;wt% MEA solvent. However, due to the undesirable insulation on the regeneration column, the reboiler heating duty recorded in the experiment was higher than the simulation results but still in an acceptable range if the heat loss was considered.</p>
</sec>
<sec id="s3-1-2">
<title>3.1.2 Validation of simulation with 30&#xa0;wt% aqueous MEA pilot plants results</title>
<p>In 3.1.1, the simulation results were validated with 20&#xa0;wt% aqueous MEA. Moreover, the experimental results with 30&#xa0;wt% MEA solutions taken from the pilot plants at the University of Texas at Austin and the University of Kaiserslautern (<xref ref-type="bibr" rid="B12">Dugas, 2006</xref>; <xref ref-type="bibr" rid="B37">Notz et al., 2012</xref>) were used for further validation.</p>
<p>For 30&#xa0;wt% MEA, again, the simulations were conducted under the same conditions used at the real pilot plants. The comparison results are listed in <xref ref-type="table" rid="T6">Table 6</xref> and depicted in <xref ref-type="fig" rid="F3">Figure 3</xref>, showing that good agreements were obtained between the simulation output and experimental data. The minor difference in the reboiler heating duty from that in the pilot plant data at the University of Texas at Austin can be explained by the re-absorption in the desorber, which was also reported by <xref ref-type="bibr" rid="B45">Zhang et al. (2009</xref>).</p>
<table-wrap id="T6" position="float">
<label>TABLE 6</label>
<caption>
<p>Simulation and experimental results for 30&#xa0;wt% MEA solvent.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="center">Variable</th>
<th align="center">Measurement (<xref ref-type="bibr" rid="B12">Dugas, 2006</xref>; <xref ref-type="bibr" rid="B37">Notz et al., 2012</xref>)</th>
<th colspan="2" align="center">Simulation output</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td colspan="4" align="center">Validation with the pilot plant at the University of Texas at Austin</td>
</tr>
<tr>
<td align="center">CO<sub>2</sub> loading in LEANOUT, mol<sub>CO2</sub>/mol<sub>MEA</sub>
</td>
<td align="center">0.286</td>
<td colspan="2" align="center">0.299</td>
</tr>
<tr>
<td align="center">CO<sub>2</sub> loading in RICHIN, mol<sub>CO2</sub>/mol<sub>MEA</sub>
</td>
<td align="center">0.539</td>
<td colspan="2" align="center">0.485</td>
</tr>
<tr>
<td align="center">CO<sub>2</sub> removal, %</td>
<td align="center">69</td>
<td colspan="2" align="center">69.3</td>
</tr>
<tr>
<td align="center">CO<sub>2</sub> stripping, kg/hr</td>
<td align="center">92</td>
<td colspan="2" align="center">94.23</td>
</tr>
<tr>
<td align="center">Reboiler heat duty, MJ/hr</td>
<td align="center">738</td>
<td colspan="2" align="center">546</td>
</tr>
<tr>
<td colspan="4" align="center">Validation with the pilot plants at the University of Kaiserslautern</td>
</tr>
<tr>
<td align="center">CO<sub>2</sub> loading in LEANIN, mol<sub>CO2</sub>/mol<sub>MEA</sub>
</td>
<td align="center">0.262</td>
<td colspan="2" align="center">0.254</td>
</tr>
<tr>
<td align="center">CO<sub>2</sub> loading in RICHOUT, mol<sub>CO2</sub>/mol<sub>MEA</sub>
</td>
<td align="center">0.387</td>
<td colspan="2" align="center">0.385</td>
</tr>
<tr>
<td align="center">CO<sub>2</sub> removal, %</td>
<td align="center">76.1</td>
<td colspan="2" align="center">85</td>
</tr>
<tr>
<td align="center">Reboiler heat duty, MJ/hr</td>
<td align="center">6.47</td>
<td colspan="2" align="center">7.048</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
</sec>
<sec id="s3-2">
<title>3.2 The effect of MEA concentrations under different selected parameters</title>
<p>For the MEA-based technologies for CO<sub>2</sub> capture, 30&#xa0;wt% MEA is often used in academic research, while a lower concentration of MEA solution is widely used in industrial applications. To further study the CO<sub>2</sub> capture performance with different MEA concentrations, solvents with 15&#x2013;30&#xa0;wt% MEA were selected to simulate the capture process with fixed inlet gas and lean loading, and the solvent flow rate was adjusted to obtain a 95% CO<sub>2</sub> removal rate. The effects of lean loading on reboiler duty were studied by Hassan et al., concluding that the minimum reboiler duty was achieved when the lean loading achieved around 0.3&#xa0;mol<sub>CO2</sub>/mol<sub>MEA</sub> (<xref ref-type="bibr" rid="B2">Abu-Zahra et al., 2007b</xref>; <xref ref-type="bibr" rid="B20">Hassan et al., 2007</xref>). Therefore, in this study, a fixed lean loading of 0.3&#xa0;mol<sub>CO2</sub>/mol<sub>MEA</sub> was used to simplify the study, and more efforts were devoted to the influence of selected parameters.</p>
<p>
<xref ref-type="fig" rid="F4">Figure 4</xref> shows that, by decreasing the MEA concentration from 30&#xa0;wt%, through 25 and 20 until 15&#xa0;wt%, the bulge temperature decreased from 358.15 to 328.15&#xa0;K, creating a better absorption performance because the lower temperature promotes the exothermic absorption for CO<sub>2</sub>. However, it is not exactly the same story when discussing the MEA concentration regarding the reboiler duty and investment cost. The specific heat requirement and cost estimation were calculated based on these four MEA concentrations and all the combinations of selected parameters. Only the cases with boundaries of the selected parameters were discussed.</p>
<fig id="F4" position="float">
<label>FIGURE 4</label>
<caption>
<p>Temperature profile and bulge temperature in the absorber.</p>
</caption>
<graphic xlink:href="fenrg-11-1230743-g004.tif"/>
</fig>
<sec id="s3-2-1">
<title>3.2.1 The effect of removal rate</title>
<p>The lower and upper boundaries of removal rate were selected to illustrate the effects of MEA concentration and removal rate on specific energy demand and capture cost with fixed gas flow rate (large scale) and CO<sub>2</sub> concentration (31.8&#xa0;wt% CO<sub>2</sub> concentration). As we can conclude from <xref ref-type="fig" rid="F5">Figure 5</xref>, no considerable effect of removal rate is observed even if the removal rate increases from 65% to 95%. However, the specific heat requirement as well as the costs are sharply decreasing with increasing MEA concentration from 15% to 20%, and then a slight decrease and increase are observed with increasing the MEA concentration from 20% to 25% and from 25% to 30%. It can be explained that when using too low MEA concentration (e.g., 15&#xa0;wt% MEA), it will lead to a large solvent flow rate and thus expand the equipment dimension and higher CAPEX. The heat demand required for heating up the solvent is also high, resulting in a sharp increase in OPEX. When increasing the MEA concentration into 20&#x2013;25&#xa0;wt%, a lower solvent flow rate could reach the fixed capture target and lower the heat requirement compared to that of 15&#xa0;wt% MEA case. The higher bulge temperature in the absorber is insignificant compared with enhancement due to the decrease in solvent flow rate. When a high MEA concentration (30&#xa0;wt% MEA) is used, a lesser solvent flow rate is required. However, the bulge temperature is too high to maintain the desired CO<sub>2</sub> solubility, again resulting in a larger solvent flow rate for compensating the solubility losses. Even though the solvent flow rate is still less than that for the case with a lower MEA concentration, the heat duty is a bit higher and not optimal in this case.</p>
<fig id="F5" position="float">
<label>FIGURE 5</label>
<caption>
<p>Influence of MEA concentration on investment cost and specific heat requirement. <bold>(A)</bold>: 65% removal rate; <bold>(B)</bold>: 95% removal rate.</p>
</caption>
<graphic xlink:href="fenrg-11-1230743-g005.tif"/>
</fig>
</sec>
<sec id="s3-2-2">
<title>3.2.2 The effect of CO<sub>2</sub> concentration</title>
<p>Similar to the evaluation of removal rate, the boundary value of CO<sub>2</sub> concentration, 10 and 50&#xa0;wt% were selected to study the effect of MEA concentration under different CO<sub>2</sub> concentrations, as depicted in <xref ref-type="fig" rid="F6">Figure 6</xref>. When the CO<sub>2</sub> concentrations were set at a 10 and 50&#xa0;wt%, the lowest specific energy demands were reached for the solvent with 25&#xa0;wt% and 20&#xa0;wt% MEA concentrations, respectively. This is highly related to the CO<sub>2</sub> concentration. When using 30&#xa0;wt% MEA with 10&#xa0;wt% CO<sub>2</sub> concentration, the higher bulge temperature is avoided, leading to an insignificant difference between 25 and 30&#xa0;wt% MEA. However, when using 30&#xa0;wt% MEA with 50&#xa0;wt% CO<sub>2</sub> concentration, the high bulge temperature is promoted, resulting in an obviously increased specific energy demand compared with the case of 25&#xa0;wt% of MEA.</p>
<fig id="F6" position="float">
<label>FIGURE 6</label>
<caption>
<p>Influence of MEA concentration on investment cost and specific heat requirement. <bold>(A)</bold>: 10&#xa0;wt% CO<sub>2</sub> concentration; <bold>(B)</bold>: 50&#xa0;wt% CO<sub>2</sub> concentration.</p>
</caption>
<graphic xlink:href="fenrg-11-1230743-g006.tif"/>
</fig>
<p>Moreover, the lowest investment costs were reached for the solvent with 25&#xa0;wt% and 20&#xa0;wt% MEA concentration when using 10 and 50&#xa0;wt% CO<sub>2</sub> concentrations, respectively. The conclusions above indicate the significant effects of CO<sub>2</sub> concentration on both energy demand and investment cost. Therefore, the solvent concentration should be carefully considered with CO<sub>2</sub> concentrations.</p>
<p>We can conclude that the MEA concentration of 20&#x2013;25&#xa0;wt% is the optimum range in our study instead of 30&#xa0;wt% MEA, and a concentration lower than 20&#xa0;wt% will significantly increase the reboiler duty. Besides, other researchers also drew a similar conclusion when the study methods are customized; <xref ref-type="bibr" rid="B18">Gar&#x111;arsd&#xf3;ttir et al. (2015</xref>) also studied the solvent concentration effect on the temperature profiles and heat duty that lower concentrations of MEA could benefit the bulge temperature in absorber and reboiler heat duty, especially under low CO<sub>2</sub> concentration condition. In addition, the pilot testing also supports that the MEA concentration lower than 30&#xa0;wt% requires lower stripping steam in the regeneration process (<xref ref-type="bibr" rid="B37">Notz et al., 2012</xref>). Furthermore, a lower MEA concentration solvent benefits a lower degradation and corrosion rates, and reduces the equipment, maintenance, and solvent costs. Based on all the analyses in this section, 20&#xa0;wt% MEA solvent was selected for further study in this work.</p>
</sec>
</sec>
<sec id="s3-3">
<title>3.3 Systematic analysis of energy demand and cost with 20&#xa0;wt% MEA</title>
<p>In this section, a systematic analysis of energy demand and cost with 20&#xa0;wt% MEA was discussed. It is worth mentioning that the ranges of the values for the defined parameters, i.e., gas flow rate, CO<sub>2</sub> concentration, and CO<sub>2</sub> removal rate, were adopted from <xref ref-type="table" rid="T2">Table 2</xref>.</p>
<sec id="s3-3-1">
<title>3.3.1 Energy demand analysis</title>
<p>First, the energy demand and variance with the studied parameters were evaluated for the process with and without the compression unit. The heating duty, cooling duty, and electric power were analyzed to identify the energy-intensive units, and then the effect of the parameters on these units was quantitatively evaluated. In this section, a number of examples are illustrated to represent the effects of parameters, and other cases have shown the same trend as the cases presented in the following sections.</p>
<p>
<xref ref-type="fig" rid="F7">Figure 7</xref> shows the results of specific energy power for different cases as well as with and without the compression unit. The specific energy power in the high CO<sub>2</sub> concentration cases was lower than that in the low CO<sub>2</sub> concentration cases. For example, with a 65% CO<sub>2</sub> removal rate, the heating duty was 0.14 kW/ton-CO<sub>2</sub> for 10&#xa0;wt% CO<sub>2</sub> concentration, while it was 0.105 kW/ton-CO<sub>2</sub> for 50&#xa0;wt% CO<sub>2</sub> concentration. Thus, the specific energy power decreased with increasing CO<sub>2</sub> concentration. In addition, the energy power decreased with increasing CO<sub>2</sub> removal rate, except for the cooling duty. For the cases with the compression unit, the cooling duty showed a fluctuation with increasing CO<sub>2</sub> removal rate owing to the design of the multistage compressors. The CO<sub>2</sub> streams contained different volumetric flow rates and temperatures, requiring various compressor setups (outlet pressure and temperature in each stage) and different cooler sizes in each stage, and influencing the overall process cooling duty.</p>
<fig id="F7" position="float">
<label>FIGURE 7</label>
<caption>
<p>Specific energy power per ton-CO<sub>2</sub> captured. Darker color: with compression, lighter color: without compression [<bold>(A)</bold>: 10&#xa0;wt% CO<sub>2</sub> case, <bold>(B)</bold>: 50&#xa0;wt% CO<sub>2</sub> case].</p>
</caption>
<graphic xlink:href="fenrg-11-1230743-g007.tif"/>
</fig>
<p>The specific energy powers include cooling, heating, and electric power. The cooling duty, which is used in pre-stage cooling and the condenser in the desorber, requires the largest percentage of energy power. There was no difference between the heating duty with and without the compression unit, because the heating duty was only owing to the reboiler. The value of electric power was lower than the other two energy powers, especially without the compression unit. The significant difference between the electric powers with and without the compressors indicates that the compressors are the main electricity requirement. The summation of heating and cooling duty accounts for the most part of the energy power required in the process, indicating that consideration of waste heating and cooling management might be interesting.</p>
<p>
<xref ref-type="fig" rid="F8">Figure 8</xref> shows the variations of the total energy cost with the considered parameters as well as with and without the compression unit, where the observations are different from those in <xref ref-type="fig" rid="F7">Figure 7</xref>. The different results observed from <xref ref-type="fig" rid="F7">Figure 7</xref> and <xref ref-type="fig" rid="F8">Figure 8</xref> highlight the importance of energy price in analyzing the economics rather than the energy demand. In contrast to <xref ref-type="fig" rid="F7">Figure 7</xref>, the cost of cooling energy in <xref ref-type="fig" rid="F8">Figure 8</xref> is insignificant compared to the overall energy cost. Moreover, the energy cost without the compression unit showed at least a 20% cost reduction from that with the compression unit; therefore, the compression unit played a significant role in the energy demand. In addition, the total energy cost slightly decreased with increasing CO<sub>2</sub> removal rate in each case; however, the reduction was large for increasing CO<sub>2</sub> concentration. For instance, for 10&#xa0;wt% CO<sub>2</sub> with the increased CO<sub>2</sub> removal rate, the reductions were 7.3% (with compression) and 7.5% (without compression), while the cost reductions owing to the increased CO<sub>2</sub> concentration were 26.4%&#x2013;30.4% and 33.7%&#x2013;37.9%, respectively.</p>
<fig id="F8" position="float">
<label>FIGURE 8</label>
<caption>
<p>Heating, cooling, and electricity cost in the MEA based CO<sub>2</sub> capture process. Darker color: with compression, lighter color: without compression. [<bold>(A)</bold>: 10&#xa0;wt% CO<sub>2</sub> case, <bold>(B)</bold>: 50&#xa0;wt% CO<sub>2</sub> case].</p>
</caption>
<graphic xlink:href="fenrg-11-1230743-g008.tif"/>
</fig>
<p>
<xref ref-type="fig" rid="F8">Figure 8</xref> also shows the energy costs of heating duty, cooling duty, and electric power. The heating duty, which is owing to the reboiler, accounts for 50% of the total energy cost in each case. For 10 and 50&#xa0;wt% CO<sub>2</sub>, the cost of the heating duty was slightly reduced: 2.7% and 1% with the increased CO<sub>2</sub> removal rate, while increasing the CO<sub>2</sub> concentration from 10 to 50&#xa0;wt% created a 23%&#x2013;24.4% reduction. Therefore, the CO<sub>2</sub> concentration had a larger effect on the cost reduction of the heating duty than that of the CO<sub>2</sub> removal rate. Large cost reductions in electric power were observed by removing the compression unit. For 10&#xa0;wt% CO<sub>2</sub> concentration, 52% and 62% reductions were observed for the 65% and 95% CO<sub>2</sub> removal rates, respectively. These numbers were larger for 50&#xa0;wt% CO<sub>2</sub> concentration: 86% and 87% reductions for the 65% and 95% CO<sub>2</sub> removal rates, respectively. When the CO<sub>2</sub> concentration increased from 10 to 50&#xa0;wt%, the additional electric power for the gas blower and solvent pumps was smaller than the reduction of the electric power for the compression unit. Therefore, the compression unit dominated the overall electric demand, especially for high CO<sub>2</sub> concentrations.</p>
<p>The effect of the CO<sub>2</sub> concentration and CO<sub>2</sub> removal rate on the electric power was further evaluated for the cases with and without the compression unit. For the cases with a compression unit, when increasing the CO<sub>2</sub> removal rate from 65% to 95%, 14.9% and 4% cost reductions were observed in the 10 and 50&#xa0;wt% CO<sub>2</sub> cases, respectively. However, the effect of the CO<sub>2</sub> concentration achieved 31.9%&#x2013;39.5% cost reductions when increasing the CO<sub>2</sub> concentration from 10 to 50&#xa0;wt% for the CO<sub>2</sub> removal rates ranging from 65% to 95%. For the cases without the compression unit, when increasing the CO<sub>2</sub> removal rate from 65% to 95%, 30.9% and 30.3% cost reductions were observed in the 10 and 50&#xa0;wt% CO<sub>2</sub> cases, while the CO<sub>2</sub> concentration showed a larger effect than that of the CO<sub>2</sub> removal rate: 82.3%&#x2013;82.5% cost reductions when increasing the CO<sub>2</sub> concentration from 10 to 50&#xa0;wt% with the CO<sub>2</sub> removal rates of 65%&#x2013;95%. In both scenarios, the CO<sub>2</sub> concentration had a larger impact than that of the CO<sub>2</sub> removal rate on the cost reductions in the electric power. The cooling duty represented a small percentage of the energy cost, and the absence of a compression unit showed a minimal effect. In addition, the percentages of heating, electricity, and cooling costs to the total costs were plotted in cheese portion diagrams in the <xref ref-type="sec" rid="s10">Supplementary Figure S1</xref> to visually demonstrate the energy cost percentages when changing the defined parameters.</p>
</sec>
<sec id="s3-3-2">
<title>3.3.2 Techno-economic analysis</title>
<p>The energy analysis is related to the operational cost. For the entire plant, the investment cost is another important concern. In this section, the effects of individual and multiple parameters on CAPEX, OPEX, and total cost were discussed. In addition, the estimated costs for the MEA-based CO<sub>2</sub> capture plant for all cases were summarized and plotted in a single figure, where CAPEX and OPEX are shown for the combinations of considered parameters. Beforehand, the sensitivity analysis of the impact of utility cost on total cost was conducted. The results are shown in the <xref ref-type="sec" rid="s10">Supplementary Figure S2</xref>. The utility costs were varied for 50%, 75%, 125%, and 150% of its original cost adopted from <xref ref-type="table" rid="T4">Table 4</xref>. Four sets of cases, i.e., large/medium flow fate with 65%/95% CO<sub>2</sub> removal rate, were selected to represent how the variations of these utility prices affect the calculated costs. The results showed that the heating cost affected the total cost in the most effective way rather than the electricity cost, and the cooling cost only slightly changed the total cost. For example, in the case of large flow fate with 65% CO<sub>2</sub> removal rate, 50% increase in heating cost caused 12.9% increase in the total cost, while 50% increase in electricity and cooling costs led to 8.4% and 1% increases in the total cost, respectively.</p>
<sec id="s3-3-2-1">
<title>3.3.2.1 Influence of CO<sub>2</sub> removal rate on the CAPEX and OPEX</title>
<p>
<xref ref-type="fig" rid="F9">Figure 9</xref> shows the influence of the CO<sub>2</sub> removal rate on the CAPEX and OPEX per ton CO<sub>2</sub>. The case with 10&#xa0;wt% CO<sub>2</sub> concentration was used as one example. A larger removal rate provided a lower CAPEX per ton CO<sub>2</sub>. However, the total CAPEX increased with increasing CO<sub>2</sub> removal rate, even though the CAPEX per ton CO<sub>2</sub> decreased. This was because of the lower increment of CAPEX than that with the extra amount of CO<sub>2</sub> captured. For OPEX, it decreased with increasing CO<sub>2</sub> removal rate, and its value was approximately 3 times that of CAPEX. Therefore, OPEX dominated the total cost in the MEA-based CO<sub>2</sub> capture process. In the large flow rate cases, the CAPEX per ton CO<sub>2</sub> decreased from $26.9 to 21.08, corresponding to a 21.6% reduction, while only a 9.4% reduction was observed for the OPEX per ton of CO<sub>2</sub>. Therefore, CAPEX was more sensitive than OPEX to the increase in the CO<sub>2</sub> removal rate.</p>
<fig id="F9" position="float">
<label>FIGURE 9</label>
<caption>
<p>Effect of the CO<sub>2</sub> removal rate on the CAPEX and OPEX per ton CO<sub>2</sub> captured (10&#xa0;wt% CO<sub>2</sub> concentration).</p>
</caption>
<graphic xlink:href="fenrg-11-1230743-g009.tif"/>
</fig>
</sec>
<sec id="s3-3-2-2">
<title>3.3.2.2 Influence of the gas flow rate on the CAPEX and OPEX</title>
<p>
<xref ref-type="fig" rid="F10">Figure 10</xref> shows the influence of the gas flow rate on the CAPEX and OPEX per ton CO<sub>2</sub> for a 65% CO<sub>2</sub> removal rate. When fixing the CO<sub>2</sub> removal rate and comparing the CAPEX for the cases with different gas flow rates, the cases with a larger gas flow rate provided a lower CAPEX per ton CO<sub>2</sub>. The doubled gas flow rate provided twice the amount of CO<sub>2</sub> gas flow; however, CAPEX was not linearly doubled, leading to a CAPEX reduction. For OPEX, when the gas flow rate was doubled from medium flow to large flow, OPEX decreased from $44.81 to 40.69 (9.1% reduction). Meanwhile, the CAPEX reduction reached approximately 25%, from $8.87 to 6.57.</p>
<fig id="F10" position="float">
<label>FIGURE 10</label>
<caption>
<p>Effect of the gas flow rate on the CAPEX and OPEX per ton CO<sub>2</sub> (65% CO<sub>2</sub> removal rate).</p>
</caption>
<graphic xlink:href="fenrg-11-1230743-g010.tif"/>
</fig>
</sec>
<sec id="s3-3-2-3">
<title>3.3.2.3 Influence of the CO<sub>2</sub> concentration on the CAPEX and OPEX</title>
<p>
<xref ref-type="fig" rid="F11">Figure 11</xref> shows the influence of the CO<sub>2</sub> concentration on the CAPEX and OPEX per ton CO<sub>2</sub>. The cases with a medium flow rate are listed as examples. When fixing the gas flow rate and comparing the cases with different CO<sub>2</sub> concentrations, the higher CO<sub>2</sub> concentration created a lower CAPEX per ton CO<sub>2</sub>. The amount of captured CO<sub>2</sub> increased with increasing CO<sub>2</sub> concentration, thus increasing the solvent flow as well as the equipment size and cost. However, the total volume of the gas stream was fixed, and the increase of CAPEX owing to the increased solvent flow and increased CO<sub>2</sub> gas flow was small compared to the extra amount of captured CO<sub>2</sub> owing to the increased CO<sub>2</sub> concentration. In addition, the increased cost of the compressors was caused by the increased amount of captured CO<sub>2</sub> exiting the desorber.</p>
<fig id="F11" position="float">
<label>FIGURE 11</label>
<caption>
<p>Effect of the CO<sub>2</sub> concentration on the CAPEX and OPEX (medium flow rate).</p>
</caption>
<graphic xlink:href="fenrg-11-1230743-g011.tif"/>
</fig>
<p>OPEX decreased with increasing CO<sub>2</sub> concentration. A sharp reduction of OPEX was obtained when the CO<sub>2</sub> concentration increased from a low value. For example, the increase of the CO<sub>2</sub> concentration from 10 to 20&#xa0;wt% provided a sharp reduction in OPEX from $78.92 to 57.75 (a reduction of 26.8%). However, a further reduction in OPEX was slower, resulting in $41.59&#xa0;at 50% CO<sub>2</sub> concentration.</p>
<p>Combining the results from <xref ref-type="fig" rid="F9">Figures 9</xref>, <xref ref-type="fig" rid="F10">10</xref>, based on the cases of large flow, 65% CO<sub>2</sub> removal rate, and increasing CO<sub>2</sub> concentration from 10 to 50&#xa0;wt%, a 75.6% CAPEX reduction was observed, i.e., from $26.9 to 6.57, while OPEX decreased from $74.03 to 40.69, i.e., 45% reduction.</p>
<p>When combining the results from <xref ref-type="fig" rid="F10">Figures 10</xref>, <xref ref-type="fig" rid="F11">11</xref>, based on the cases of medium flow, 50&#xa0;wt% CO<sub>2</sub> concentration, with an increasing CO<sub>2</sub> removal rate from 65% to 95%, a 19.7% CAPEX reduction was observed, i.e., from $8.87 to 7.12, while OPEX decreased from $44.81 to 41.59, i.e., 7.2% reduction.</p>
<p>From <xref ref-type="fig" rid="F9">Figures 9</xref>, <xref ref-type="fig" rid="F11">11</xref>, for a 95% CO<sub>2</sub> removal rate, 10&#xa0;wt% CO<sub>2</sub> concentration showed a 66.2% CAPEX reduction by increasing the gas flow rate from medium to large scales, i.e., $21.08 to 7.12, while OPEX decreased from $67.09 to 41.59, i.e., 38% reduction.</p>
<p>The individual and multiple parameter studies revealed that CAPEX was more sensitive to the considered parameters than that of OPEX in percentage. However, the absolute value of OPEX was larger than that of CAPEX, and thus, OPEX accounted for a greater proportion of the total investment cost. The next section discussed the OPEX percentage change with parameter variations.</p>
</sec>
<sec id="s3-3-2-4">
<title>3.3.2.4 Change in the OPEX percentage with parameter variations</title>
<p>
<xref ref-type="fig" rid="F12">Figure 12</xref> shows the OPEX percentage with respect to the total cost. When the CO<sub>2</sub> concentration increased from 10 to 50&#xa0;wt%, the OPEX percentage increased. When the CO<sub>2</sub> removal rate and gas flow rate were fixed, the increased CO<sub>2</sub> concentration required more CO<sub>2</sub> to be treated to achieve the same removal rate, and more power and heat were required to achieve the capture task. Meanwhile, the equipment size would not change owing to the fixed gas flow rate, as the gas flow rate is the decisive factor for sizing the equipment. In addition, the increased rate of OPEX decreased with increasing CO<sub>2</sub> concentration; thus, OPEX was more sensitive at a low CO<sub>2</sub> concentration.</p>
<fig id="F12" position="float">
<label>FIGURE 12</label>
<caption>
<p>OPEX percentage variations.</p>
</caption>
<graphic xlink:href="fenrg-11-1230743-g012.tif"/>
</fig>
<p>When fixing the CO<sub>2</sub> concentration, the increased CO<sub>2</sub> removal rate from 65% to 95% increased the OPEX percentage. When the capture requirement increased, the solvent flow rate and regeneration energy increased, leading to a high OPEX percentage. However, the increase of OPEX percentage became slow at a high CO<sub>2</sub> removal rate; therefore, the OPEX was more sensitive at the low CO<sub>2</sub> removal rate.</p>
</sec>
</sec>
</sec>
<sec id="s3-4">
<title>3.4 Overall economic analysis results</title>
<p>CAPEX, OPEX, and total cost of all the studied cases (all combinations of gas flow rates, CO<sub>2</sub> concentrations, and CO<sub>2</sub> removal rates) are shown in <xref ref-type="fig" rid="F13">Figure 13</xref>. CAPEX and OPEX decreased with 1) increasing CO<sub>2</sub> concentration, 2) increasing CO<sub>2</sub> removal rate, and 3) increasing gas flow rate. The individual evaluation of each parameter on cost indicated that all three parameters had a larger impact on CAPEX than that of OPEX proportionally. However, OPEX dominated the total cost owing to its larger absolute value (approximately three times that of CAPEX). Consequently, if the percentage change is smaller in OPEX than in CAPEX, the change in the total investment cost (in $) is larger in OPEX than in CAPEX. Additionally, non-linear relationships between the defined parameters and CAPEX, OPEX, and total cost were observed in <xref ref-type="fig" rid="F13">Figure 13</xref>. This non-linearity can be attributed to the effect of sole parameter (i.e., CO<sub>2</sub> removal rate affects the sizes/costs of absorber and desorber) and/or multiple parameters (i.e., gas flow rate and CO<sub>2</sub> concentration collectively affect the size of absorber and the electric power demand), making it necessary and meaningful to conduct further detailed systematic study and analysis to quantitatively identify the reasons behind these observations.</p>
<fig id="F13" position="float">
<label>FIGURE 13</label>
<caption>
<p>Annualized <bold>(A)</bold> CAPEX and OPEX, and <bold>(B)</bold> annualized total investment cost.</p>
</caption>
<graphic xlink:href="fenrg-11-1230743-g013.tif"/>
</fig>
</sec>
<sec id="s3-5">
<title>3.5 Further discussions on the practical implementation</title>
<p>Based on the overall economic analysis, suggestions were provided for the CO<sub>2</sub> capture plant in an industry based on a new or existing plant.</p>
<p>As summarized in <xref ref-type="sec" rid="s3-4">Section 3.4</xref>, the total cost decreased with increasing the values of parameters. In order to reach the optimal economic situation, a newly designed plant should be operated with a high gas flow rate, the CO<sub>2</sub> concentration should be as high as possible, and the capture plant should aim for the highest CO<sub>2</sub> removal rate.</p>
<p>For adding a CO<sub>2</sub> capture process to an existing plant, the most effective method to decrease the cost of CO<sub>2</sub> capture is to increase the CO<sub>2</sub> concentration, especially for plants with low CO<sub>2</sub> concentrations. When the CO<sub>2</sub> concentration increased from 10 to 20&#xa0;wt%, the total investment cost decreased from $126.56 to 83.17 (i.e., 34.3% reduction) for the case with a 65% removal rate, medium flow, and 10&#xa0;wt% CO<sub>2</sub>. However, this method required a large modification of the production process, which could be expensive. In addition, increasing the gas flow rate could reduce the investment cost, and thus, a fully operational plant is preferred for the capture plant economy. Finally, the highest CO<sub>2</sub> removal rate should be used, without significantly influencing the plant operation. Although the effectiveness of increasing the CO<sub>2</sub> removal rate was lower than that of the other two factors, the efficiency of increasing CO<sub>2</sub> removal rate showed greater potential in a lower CO<sub>2</sub> removal rate range.</p>
</sec>
</sec>
<sec sec-type="conclusion" id="s4">
<title>4 Conclusion</title>
<p>The MEA-based CO<sub>2</sub> capture process was studied systematically, including experimental measurements and process simulations with different MEA-concentrations and parameters, with and without the compression unit. The comparison of the simulations with the newly measured experimental data and those from the real pilot plants ensured reliable simulations, and 20&#xa0;wt% MEA solution was identified as the optimal concentration. The energy evaluation results revealed that the cooling duty required the largest energy power; however, the heating duty accounted for the largest energy demand based on the energy price. The heating duty contributed to more than 50% of the total energy cost in all cases, regardless of the presence of the compression unit. In addition, the compression unit used more than half of the required electric power, especially for the large CO<sub>2</sub> concentration cases.</p>
<p>The qualitative evaluation and comparison of the effect of each parameter on cost indicated that the CO<sub>2</sub> concentration and gas flow rate had larger influences than that of the CO<sub>2</sub> removal rate. Since the extent of influence for each defined parameter was difficult to measure and compare, in other words, the parameters were at different dimensions, i.e., gas flow rate in ton/hr, CO<sub>2</sub> concentration in weight percentage; the CO<sub>2</sub> concentration ranging from 10 to 50&#xa0;wt% while the CO<sub>2</sub> removal rate being &#x2265;65% owing to the CO<sub>2</sub> capture requirements, it is impossible to conduct quantitative analysis. However, the cost variance trends with the studied parameters were established, and the results provided an optimal solution for process modification. In addition, the CAPEX percentage was more sensitive to all the studied parameters than that of OPEX; however, the study showed that OPEX dominated the total investment costs owing to its larger absolute value (approximately 3 times of CAPEX). Therefore, a small percentage change in OPEX affected the total investment cost more than that in CAPEX.</p>
<p>Suggestions were provided for the capture plant of new and existing plants based on the impact of the studied parameters (CO<sub>2</sub> concentration, gas flow rate, and CO<sub>2</sub> removal rate). From the overall economic analysis plot, the capture plant for a new plant should be designed to process a fully operational plant, where the flow rate, CO<sub>2</sub> concentration, and CO<sub>2</sub> removal rate are as high as possible. For an existing plant, although increasing the CO<sub>2</sub> concentration and gas flow rate were effective methods for improving the economy, running the capture plant with the highest CO<sub>2</sub> removal rate reduced the total investment cost.</p>
<p>This systematic techno-economic analysis with the MEA-based CO<sub>2</sub> capture process in the industry provided valuable energy and economic data under various parameters, and thus further comparison could be performed with other commercially or newly developed solvents. MEA aqueous solvent is the benchmark solvent in the CO<sub>2</sub> capture area, owing to its high thermal stability, excellent CO<sub>2</sub> capacity, low cost in the solvent price, and easy process operation. However, high thermal regeneration energy demand and the critical problem with high MEA concentration also limit the application. Therefore, a great interest should be in the techno-economic comparison between the MEA-based solvent and other commercially or newly developed solvents, such as advanced amines with great potential and competitivity in terms of amine concentration and regeneration energy demand; ionic liquids with potentials in the concepts of green solvent and designability, where the data provided in this work can be widely used. Furthermore, the generated energy and cost data for carbon capture technologies can also be used in a long-term energy system optimization model to assess the transition to a carbon-neutral industry. For example, the energy system model describes the material and energy flows for analyzing synergies and obstacles in transitioning to a climate-neutral society, where collective data from various industrial sectors, including material and energy flows as well as the carbon footprints, are required.</p>
</sec>
</body>
<back>
<sec sec-type="data-availability" id="s5">
<title>Data availability statement</title>
<p>The original contributions presented in the study are included in the article/<xref ref-type="sec" rid="s10">Supplementary Material</xref>, further inquiries can be directed to the corresponding authors.</p>
</sec>
<sec id="s6">
<title>Author contributions</title>
<p>NW: Conceptualization, Investigation, Methodology, Validation, Writing&#x2013;original draft, Writing, review and editing. DW: Investigation, review, and editing. AK-R: Supervision, Writing, review and editing. XJ: Conceptualization, Supervision, Writing&#x2013;original draft, Writing, review and editing. All authors contributed to the article and approved the submitted version.</p>
</sec>
<sec id="s7">
<title>Funding</title>
<p>This work was supported by the Swedish Energy Agency (grant number: P44678-1) and the Joint Research Fund for Overseas Chinese Scholars and Scholars in Hong Kong and Macao Young Scholars (No. 21729601).</p>
</sec>
<sec sec-type="COI-statement" id="s8">
<title>Conflict of interest</title>
<p>Author DW was employed by the company Sinopec Nanjing Chemical Research Institute.</p>
<p>The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec sec-type="disclaimer" id="s9">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<sec id="s10">
<title>Supplementary material</title>
<p>The Supplementary Material for this article can be found online at: <ext-link ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/fenrg.2023.1230743/full#supplementary-material">https://www.frontiersin.org/articles/10.3389/fenrg.2023.1230743/full&#x23;supplementary-material</ext-link>
</p>
<supplementary-material xlink:href="DataSheet1.PDF" id="SM1" mimetype="application/PDF" xmlns:xlink="http://www.w3.org/1999/xlink"/>
</sec>
<ref-list>
<title>References</title>
<ref id="B1">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Abu-Zahra</surname>
<given-names>M. R.</given-names>
</name>
<name>
<surname>Niederer</surname>
<given-names>J. P.</given-names>
</name>
<name>
<surname>Feron</surname>
<given-names>P. H.</given-names>
</name>
<name>
<surname>Versteeg</surname>
<given-names>G. F.</given-names>
</name>
</person-group> (<year>2007a</year>). <article-title>CO<sub>2</sub> capture from power plants: part II. A parametric study of the economical performance based on mono-ethanolamine</article-title>. <source>Int. J. Greenh. gas control</source> <volume>1</volume>, <fpage>135</fpage>&#x2013;<lpage>142</lpage>. <pub-id pub-id-type="doi">10.1016/s1750-5836(07)00032-1</pub-id>
</citation>
</ref>
<ref id="B2">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Abu-Zahra</surname>
<given-names>M. R. M.</given-names>
</name>
<name>
<surname>Schneiders</surname>
<given-names>L. H. J.</given-names>
</name>
<name>
<surname>Niederer</surname>
<given-names>J. P. M.</given-names>
</name>
<name>
<surname>Feron</surname>
<given-names>P. H. M.</given-names>
</name>
<name>
<surname>Versteeg</surname>
<given-names>G. F.</given-names>
</name>
</person-group> (<year>2007b</year>). <article-title>CO<sub>2</sub> capture from power plants. Part I. A parametric study of the technical-performance based on monoethanolamine</article-title>. <source>Int. J. Greenh. Gas Control</source> <volume>1</volume>, <fpage>37</fpage>&#x2013;<lpage>46</lpage>. <pub-id pub-id-type="doi">10.1016/s1750-5836(06)00007-7</pub-id>
</citation>
</ref>
<ref id="B3">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Arachchige</surname>
<given-names>U. S. P. R.</given-names>
</name>
<name>
<surname>Melaaen</surname>
<given-names>M. C.</given-names>
</name>
</person-group> (<year>2012</year>). <article-title>Aspen plus simulation of CO<sub>2</sub> removal from coal and gas fired power plants</article-title>. <source>Enrgy Proced.</source> <volume>23</volume>, <fpage>391</fpage>&#x2013;<lpage>399</lpage>. <pub-id pub-id-type="doi">10.1016/j.egypro.2012.06.060</pub-id>
</citation>
</ref>
<ref id="B4">
<citation citation-type="book">
<collab>Aspen</collab> (<year>2010</year>). <source>Aspen process economic analyzer V7.2 user guide</source>.</citation>
</ref>
<ref id="B5">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Austgen</surname>
<given-names>D. M.</given-names>
</name>
<name>
<surname>Rochelle</surname>
<given-names>G. T.</given-names>
</name>
<name>
<surname>Peng</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>C. C.</given-names>
</name>
</person-group> (<year>1989</year>). <article-title>Model of vapor-liquid equilibria for aqueous acid gas-alkanolamine systems using the electrolyte-NRTL equation</article-title>. <source>Industrial Eng. Chem. Res.</source> <volume>28</volume>, <fpage>1060</fpage>&#x2013;<lpage>1073</lpage>. <pub-id pub-id-type="doi">10.1021/ie00091a028</pub-id>
</citation>
</ref>
<ref id="B6">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Biegler</surname>
<given-names>L. T.</given-names>
</name>
<name>
<surname>Grossmann</surname>
<given-names>I. E.</given-names>
</name>
<name>
<surname>Westerberg</surname>
<given-names>A. W.</given-names>
</name>
</person-group> (<year>1997</year>). <source>Systematic methods for chemical process design</source>. <publisher-name>Prentice Hall PTR</publisher-name>.</citation>
</ref>
<ref id="B7">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Bravo</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Rocha</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Fair</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>1992</year>). &#x201c;<article-title>A comprehensive model for the performance of columns containing structured packings</article-title>,&#x201d; in <source>Institution of chemical engineers symposium series</source> (<publisher-name>HEMSPHERE PUBLISHING CORPORATION</publisher-name>), <fpage>A489</fpage>.</citation>
</ref>
<ref id="B8">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Chalmers</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Gibbins</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2007</year>). <article-title>Initial evaluation of the impact of post-combustion capture of carbon dioxide on supercritical pulverised coal power plant part load performance</article-title>. <source>Fuel</source> <volume>86</volume>, <fpage>2109</fpage>&#x2013;<lpage>2123</lpage>. <pub-id pub-id-type="doi">10.1016/j.fuel.2007.01.028</pub-id>
</citation>
</ref>
<ref id="B9">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Dave</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Do</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Palfreyman</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Feron</surname>
<given-names>P.</given-names>
</name>
</person-group> (<year>2011</year>). <article-title>Impact of post combustion capture of CO<sub>2</sub> on existing and new Australian coal-fired power plants</article-title>. <source>Energy Procedia</source> <volume>4</volume>, <fpage>2005</fpage>&#x2013;<lpage>2019</lpage>. <pub-id pub-id-type="doi">10.1016/j.egypro.2011.02.082</pub-id>
</citation>
</ref>
<ref id="B10">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Duan</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Zhao</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Yang</surname>
<given-names>Y.</given-names>
</name>
</person-group> (<year>2012</year>). <article-title>Integration and optimization study on the coal-fired power plant with CO<sub>2</sub> capture using MEA</article-title>. <source>Energy</source> <volume>45</volume>, <fpage>107</fpage>&#x2013;<lpage>116</lpage>. <pub-id pub-id-type="doi">10.1016/j.energy.2011.12.014</pub-id>
</citation>
</ref>
<ref id="B11">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Dubois</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Thomas</surname>
<given-names>D.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Comparison of various configurations of the absorption-regeneration process using different solvents for the post-combustion CO<sub>2</sub> capture applied to cement plant flue gases</article-title>. <source>Int. J. Greenh. Gas Control</source> <volume>69</volume>, <fpage>20</fpage>&#x2013;<lpage>35</lpage>. <pub-id pub-id-type="doi">10.1016/j.ijggc.2017.12.004</pub-id>
</citation>
</ref>
<ref id="B12">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Dugas</surname>
<given-names>R. E.</given-names>
</name>
</person-group> (<year>2006</year>). <source>Pilot plant study of carbon dioxide capture by aqueous monoethanolamine</source>. <comment>MSE Thesis</comment>. <publisher-loc>Waterloo</publisher-loc>: <publisher-name>University of Texas at Austin</publisher-name>.</citation>
</ref>
<ref id="B13">
<citation citation-type="book">
<collab>Eurostat</collab> (<year>2016</year>). <source>Electricity prices for industrial consumers, second half 2016 (EUR per kWh)</source>. <comment>Available at: <ext-link ext-link-type="uri" xlink:href="https://ec.europa.eu/eurostat/statistics-explained/index.php&#x3f;title&#x3d;Main&#x005f;Page">https://ec.europa.eu/eurostat/statistics-explained/index.php&#x3f;title&#x3d;Main&#x005f;Page</ext-link>
</comment>.</citation>
</ref>
<ref id="B14">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Freguia</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Rochelle</surname>
<given-names>G. T.</given-names>
</name>
</person-group> (<year>2003</year>). <article-title>Modeling of CO<sub>2</sub> capture by aqueous monoethanolamine</article-title>. <source>AIChE J.</source> <volume>49</volume>, <fpage>1676</fpage>&#x2013;<lpage>1686</lpage>. <pub-id pub-id-type="doi">10.1002/aic.690490708</pub-id>
</citation>
</ref>
<ref id="B15">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Fytianos</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Ucar</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Grimstvedt</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Hyldbakk</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Svendsen</surname>
<given-names>H. F.</given-names>
</name>
<name>
<surname>Knuutila</surname>
<given-names>H. K.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Corrosion and degradation in MEA based post-combustion CO<sub>2</sub> capture</article-title>. <source>Int. J. Greenh. Gas Control</source> <volume>46</volume>, <fpage>48</fpage>&#x2013;<lpage>56</lpage>. <pub-id pub-id-type="doi">10.1016/j.ijggc.2015.12.028</pub-id>
</citation>
</ref>
<ref id="B16">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Garcia</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Knuutila</surname>
<given-names>H. K.</given-names>
</name>
<name>
<surname>Gu</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>ASPEN PLUS simulation model for CO<sub>2</sub> removal with MEA: validation of desorption model with experimental data</article-title>. <source>J. Environ. Chem. Eng.</source> <volume>5</volume>, <fpage>4693</fpage>&#x2013;<lpage>4701</lpage>. <pub-id pub-id-type="doi">10.1016/j.jece.2017.08.024</pub-id>
</citation>
</ref>
<ref id="B17">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gardarsdottir</surname>
<given-names>S. O.</given-names>
</name>
<name>
<surname>Normann</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Andersson</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Johnsson</surname>
<given-names>F.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>Postcombustion CO<sub>2</sub> capture using monoethanolamine and ammonia solvents: the influence of CO<sub>2</sub> concentration on technical performance</article-title>. <source>Industrial Eng. Chem. Res.</source> <volume>54</volume>, <fpage>681</fpage>&#x2013;<lpage>690</lpage>. <pub-id pub-id-type="doi">10.1021/ie503852m</pub-id>
</citation>
</ref>
<ref id="B18">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gar&#x111;arsd&#xf3;ttir</surname>
<given-names>S. O.</given-names>
</name>
<name>
<surname>Normann</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Andersson</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Johnsson</surname>
<given-names>F.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>Postcombustion CO<sub>2</sub> capture using monoethanolamine and ammonia solvents: the influence of CO<sub>2</sub> concentration on technical performance</article-title>. <source>Industrial Eng. Chem. Res.</source> <volume>54</volume>, <fpage>681</fpage>&#x2013;<lpage>690</lpage>. <pub-id pub-id-type="doi">10.1021/ie503852m</pub-id>
</citation>
</ref>
<ref id="B19">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gupta</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Mondal</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Das</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Deogam</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Barma</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Mandal</surname>
<given-names>B.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>Modeling and simulation for post-combustion carbon dioxide capture from power plant flue gas with economic analysis</article-title>. <source>Sep. Sci. Technol.</source> <volume>50</volume>, <fpage>1952</fpage>&#x2013;<lpage>1963</lpage>. <pub-id pub-id-type="doi">10.1080/01496395.2015.1016531</pub-id>
</citation>
</ref>
<ref id="B20">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hassan</surname>
<given-names>S. M. N.</given-names>
</name>
<name>
<surname>Douglas</surname>
<given-names>P. L.</given-names>
</name>
<name>
<surname>Croiset</surname>
<given-names>E.</given-names>
</name>
</person-group> (<year>2007</year>). <article-title>Techno-economic study of CO<sub>2</sub> capture from an existing cement plant using MEA scrubbing</article-title>. <source>Int. J. Green Energy</source> <volume>4</volume>, <fpage>197</fpage>&#x2013;<lpage>220</lpage>. <pub-id pub-id-type="doi">10.1080/01971520600873418</pub-id>
</citation>
</ref>
<ref id="B21">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Hassan</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2005</year>). <source>Techno-economic study of CO<sub>2</sub> capture process for cement plants</source>. <publisher-loc>Waterloo</publisher-loc>: <publisher-name>University of Waterloo</publisher-name>.</citation>
</ref>
<ref id="B22">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hills</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Leeson</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Florin</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Fennell</surname>
<given-names>P.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>Carbon capture in the cement industry: technologies, progress, and retrofitting</article-title>. <source>Environ. Sci. Technol.</source> <volume>50</volume>, <fpage>368</fpage>&#x2013;<lpage>377</lpage>. <pub-id pub-id-type="doi">10.1021/acs.est.5b03508</pub-id>
</citation>
</ref>
<ref id="B23">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hikita</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Asai</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Ishikawa</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Honda</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>1977</year>). <article-title>The kinetics of reactions of carbon dioxide with monoethanolamine, diethanolamine and triethanolamine by a rapid mixing method</article-title>. <source>Chem. Eng. J.</source> <volume>13</volume>, <fpage>7</fpage>&#x2013;<lpage>12</lpage>. <pub-id pub-id-type="doi">10.1016/0300-9467(77)80002-6</pub-id>
</citation>
</ref>
<ref id="B24">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Jakobsen</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Roussanaly</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Anantharaman</surname>
<given-names>R.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>A techno-economic case study of CO<sub>2</sub> capture, transport and storage chain from a cement plant in Norway</article-title>. <source>J. Clean. Prod.</source> <volume>144</volume>, <fpage>523</fpage>&#x2013;<lpage>539</lpage>. <pub-id pub-id-type="doi">10.1016/j.jclepro.2016.12.120</pub-id>
</citation>
</ref>
<ref id="B25">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Laribi</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Dubois</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>De Weireld</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Thomas</surname>
<given-names>D.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Study of the post-combustion CO<sub>2</sub> capture process by absorption-regeneration using amine solvents applied to cement plant flue gases with high CO<sub>2</sub> contents</article-title>. <source>Int. J. Greenh. Gas Control</source> <volume>90</volume>, <fpage>102799</fpage>. <pub-id pub-id-type="doi">10.1016/j.ijggc.2019.102799</pub-id>
</citation>
</ref>
<ref id="B26">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Li</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Tharakan</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Macdonald</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Liang</surname>
<given-names>X.</given-names>
</name>
</person-group> (<year>2013</year>). <article-title>Technological, economic and financial prospects of carbon dioxide capture in the cement industry</article-title>. <source>Energy Policy</source> <volume>61</volume>, <fpage>1377</fpage>&#x2013;<lpage>1387</lpage>. <pub-id pub-id-type="doi">10.1016/j.enpol.2013.05.082</pub-id>
</citation>
</ref>
<ref id="B27">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Li</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>C.</given-names>
</name>
</person-group> (<year>2014</year>). <article-title>Experimental and rate&#x2010;based modeling study of CO<sub>2</sub> capture by aqueous monoethanolamine</article-title>. <source>Greenh. Gases Sci. Technol.</source> <volume>4</volume>, <fpage>495</fpage>&#x2013;<lpage>508</lpage>. <pub-id pub-id-type="doi">10.1002/ghg.1419</pub-id>
</citation>
</ref>
<ref id="B28">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Li</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Leigh</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Feron</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Yu</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Tade</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2016a</year>). <article-title>Systematic study of aqueous monoethanolamine (MEA)-based CO<sub>2</sub> capture process: techno-economic assessment of the MEA process and its improvements</article-title>. <source>Appl. energy</source> <volume>165</volume>, <fpage>648</fpage>&#x2013;<lpage>659</lpage>. <pub-id pub-id-type="doi">10.1016/j.apenergy.2015.12.109</pub-id>
</citation>
</ref>
<ref id="B29">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Li</surname>
<given-names>K. K.</given-names>
</name>
<name>
<surname>Cousins</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Yu</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Feron</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Tade</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Luo</surname>
<given-names>W. L.</given-names>
</name>
<etal/>
</person-group> (<year>2016b</year>). <article-title>Systematic study of aqueous monoethanolamine-based CO<sub>2</sub> capture process: model development and process improvement</article-title>. <source>Energy Sci. Eng.</source> <volume>4</volume>, <fpage>23</fpage>&#x2013;<lpage>39</lpage>. <pub-id pub-id-type="doi">10.1002/ese3.101</pub-id>
</citation>
</ref>
<ref id="B30">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Liu</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Watanasiri</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>1999</year>). <article-title>Representing vapor&#x2212; liquid equilibrium for an aqueous MEA&#x2212; CO<sub>2</sub> system using the electrolyte nonrandom-two-liquid model</article-title>. <source>Industrial Eng. Chem. Res.</source> <volume>38</volume>, <fpage>2080</fpage>&#x2013;<lpage>2090</lpage>. <pub-id pub-id-type="doi">10.1021/ie980600v</pub-id>
</citation>
</ref>
<ref id="B31">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Liu</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Jia</surname>
<given-names>W.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Process simulation of CO<sub>2</sub> capture from CO<sub>2</sub>-EOR associated petroleum gas with aqueous MEA and MDEA solvents</article-title>. <source>Energy Sci. Eng.</source> <volume>7</volume>, <fpage>663</fpage>&#x2013;<lpage>675</lpage>. <pub-id pub-id-type="doi">10.1002/ese3.308</pub-id>
</citation>
</ref>
<ref id="B32">
<citation citation-type="book">
<person-group person-group-type="editor">
<name>
<surname>Masson-Delmotte</surname>
<given-names>V.</given-names>
</name>
<name>
<surname>Zhai</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>P&#xf6;rtner</surname>
<given-names>H. O.</given-names>
</name>
<name>
<surname>Roberts</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Skea</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Shukla</surname>
<given-names>P. R.</given-names>
</name>
<etal/>
</person-group> (Editors) (<year>2018</year>). &#x201c;<article-title>IPCC, 2018: summary for policymakers</article-title>,&#x201d;. <source>Global Warming of 1.5&#xb0;C. An IPCC Special Report on the impacts of global warming of 1.5&#xb0;C above pre-industrial levels and related global greenhouse gas emission pathways, in the context of strengthening the global response to the threat of climate change, sustainable development, and efforts to eradicate poverty</source>. <comment>In Press</comment>.</citation>
</ref>
<ref id="B33">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mathisen</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>S&#xf8;rensen</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Melaaen</surname>
<given-names>M. C.</given-names>
</name>
<name>
<surname>M&#xfc;ller</surname>
<given-names>G-I.</given-names>
</name>
</person-group> (<year>2013</year>). <article-title>Investigation into optimal CO<sub>2</sub> concentration for CO<sub>2</sub> capture from aluminium production</article-title>. <source>Energy Procedia</source> <volume>37</volume>, <fpage>7168</fpage>&#x2013;<lpage>7175</lpage>. <pub-id pub-id-type="doi">10.1016/j.egypro.2013.06.654</pub-id>
</citation>
</ref>
<ref id="B34">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mathisen</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>S&#xf8;rensen</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Eldrup</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Skagestad</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Melaaen</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>M&#xfc;ller</surname>
<given-names>G. I.</given-names>
</name>
</person-group> (<year>2014</year>). <article-title>Cost optimised CO<sub>2</sub> capture from aluminium production</article-title>. <source>Energy Procedia</source> <volume>51</volume>, <fpage>184</fpage>&#x2013;<lpage>190</lpage>. <pub-id pub-id-type="doi">10.1016/j.egypro.2014.07.021</pub-id>
</citation>
</ref>
<ref id="B35">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Moioli</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Pellegrini</surname>
<given-names>L. A.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Operating the CO<sub>2</sub> absorption plant in a post-combustion unit in flexible mode for cost reduction</article-title>. <source>Chem. Eng. Res. Des.</source> <volume>147</volume>, <fpage>604</fpage>&#x2013;<lpage>614</lpage>. <pub-id pub-id-type="doi">10.1016/j.cherd.2019.03.027</pub-id>
</citation>
</ref>
<ref id="B36">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Nguyen</surname>
<given-names>T. B.</given-names>
</name>
<name>
<surname>Zondervan</surname>
<given-names>E.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Ionic liquid as a selective capture method of CO<sub>2</sub> from different sources: comparison with MEA</article-title>. <source>ACS Sustain. Chem. Eng.</source> <volume>6</volume>, <fpage>4845</fpage>&#x2013;<lpage>4853</lpage>. <pub-id pub-id-type="doi">10.1021/acssuschemeng.7b04247</pub-id>
</citation>
</ref>
<ref id="B37">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Notz</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Mangalapally</surname>
<given-names>H. P.</given-names>
</name>
<name>
<surname>Hasse</surname>
<given-names>H.</given-names>
</name>
</person-group> (<year>2012</year>). <article-title>Post combustion CO<sub>2</sub> capture by reactive absorption: pilot plant description and results of systematic studies with MEA</article-title>. <source>Int. J. Greenh. Gas Control</source> <volume>6</volume>, <fpage>84</fpage>&#x2013;<lpage>112</lpage>. <pub-id pub-id-type="doi">10.1016/j.ijggc.2011.11.004</pub-id>
</citation>
</ref>
<ref id="B38">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Penteado</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Esche</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Salerno</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Godini</surname>
<given-names>H. R.</given-names>
</name>
<name>
<surname>Wozny</surname>
<given-names>G.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Design and assessment of a membrane and absorption based carbon dioxide removal process for oxidative coupling of methane</article-title>. <source>Industrial Eng. Chem. Res.</source> <volume>55</volume>, <fpage>7473</fpage>&#x2013;<lpage>7483</lpage>. <pub-id pub-id-type="doi">10.1021/acs.iecr.5b04910</pub-id>
</citation>
</ref>
<ref id="B39">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pinsent</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Pearson</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Roughton</surname>
<given-names>F.</given-names>
</name>
</person-group> (<year>1956</year>). <article-title>The kinetics of combination of carbon dioxide with hydroxide ions</article-title>. <source>Trans. Faraday Soc.</source> <volume>52</volume>, <fpage>1512</fpage>&#x2013;<lpage>1520</lpage>. <pub-id pub-id-type="doi">10.1039/tf9565201512</pub-id>
</citation>
</ref>
<ref id="B41">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sundqvist</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Biermann</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Normann</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Larsson</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Nilsson</surname>
<given-names>L.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Evaluation of low and high level integration options for carbon capture at an integrated iron and steel mill</article-title>. <source>Int. J. Greenh. Gas Control</source> <volume>77</volume>, <fpage>27</fpage>&#x2013;<lpage>36</lpage>. <pub-id pub-id-type="doi">10.1016/j.ijggc.2018.07.008</pub-id>
</citation>
</ref>
<ref id="B42">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Thiele</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Faber</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Repke</surname>
<given-names>J-U.</given-names>
</name>
<name>
<surname>Thielert</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Wozny</surname>
<given-names>G.</given-names>
</name>
</person-group> (<year>2007</year>). <article-title>Design of industrial reactive absorption processes in sour gas treatment using rigorous modelling and accurate experimentation</article-title>. <source>Chem. Eng. Res. Des.</source> <volume>85</volume>, <fpage>74</fpage>&#x2013;<lpage>87</lpage>. <pub-id pub-id-type="doi">10.1205/cherd06091</pub-id>
</citation>
</ref>
<ref id="B43">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Wagner</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Judd</surname>
<given-names>B.</given-names>
</name>
</person-group> (<year>2006</year>). &#x201c;<article-title>Gas sweetening fundamentals</article-title>,&#x201d; in <conf-name>Proceedings of the 56thLaurance reid gas conditioning conference</conf-name>, <conf-loc>Norman, OK</conf-loc>, <fpage>1</fpage>&#x2013;<lpage>54</lpage>.</citation>
</ref>
<ref id="B44">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>C-C.</given-names>
</name>
</person-group> (<year>2010</year>). <article-title>Thermodynamic modeling for CO<sub>2</sub> absorption in aqueous MDEA solution with electrolyte NRTL model</article-title>. <source>Industrial Eng. Chem. Res.</source> <volume>50</volume>, <fpage>163</fpage>&#x2013;<lpage>175</lpage>. <pub-id pub-id-type="doi">10.1021/ie1006855</pub-id>
</citation>
</ref>
<ref id="B45">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>C-C.</given-names>
</name>
<name>
<surname>Plaza</surname>
<given-names>J. M.</given-names>
</name>
<name>
<surname>Dugas</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Rochelle</surname>
<given-names>G. T.</given-names>
</name>
</person-group> (<year>2009</year>). <article-title>Rate-based process modeling study of CO<sub>2</sub> capture with aqueous monoethanolamine solution</article-title>. <source>Industrial Eng. Chem. Res.</source> <volume>48</volume>, <fpage>9233</fpage>&#x2013;<lpage>9246</lpage>. <pub-id pub-id-type="doi">10.1021/ie900068k</pub-id>
</citation>
</ref>
</ref-list>
</back>
</article>