<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="research-article" dtd-version="2.3" xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Energy Res.</journal-id>
<journal-title>Frontiers in Energy Research</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Energy Res.</abbrev-journal-title>
<issn pub-type="epub">2296-598X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">989883</article-id>
<article-id pub-id-type="doi">10.3389/fenrg.2022.989883</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Energy Research</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Numerical investigations on oscillating aspirations controlling separation flows in linear highly loaded compressor cascades</article-title>
<alt-title alt-title-type="left-running-head">Liu et al.</alt-title>
<alt-title alt-title-type="right-running-head">
<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3389/fenrg.2022.989883">10.3389/fenrg.2022.989883</ext-link>
</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Liu</surname>
<given-names>Bao</given-names>
</name>
<uri xlink:href="https://loop.frontiersin.org/people/2004400/overview"/>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Cai</surname>
<given-names>Le</given-names>
</name>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1870255/overview"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Xu</surname>
<given-names>Hao</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Fu</surname>
<given-names>Haiyan</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Wang</surname>
<given-names>Songtao</given-names>
</name>
<uri xlink:href="https://loop.frontiersin.org/people/1402167/overview"/>
</contrib>
</contrib-group>
<aff>
<institution>School of Energy Science and Engineering</institution>, <institution>Harbin Institute of Technology</institution>, <addr-line>Harbin</addr-line>, <country>China</country>
</aff>
<author-notes>
<fn fn-type="edited-by">
<p>
<bold>Edited by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/920453/overview">Kaiqiang Zhang</ext-link>, Imperial College London, United Kingdom</p>
</fn>
<fn fn-type="edited-by">
<p>
<bold>Reviewed by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1514346/overview">Xiaoxu Kan</ext-link>, Shanghai Maritime University, China</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1789010/overview">Shaopeng Lu</ext-link>, Shanghai Jiao Tong University, China</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1792123/overview">Hongxin Zhang</ext-link>, Nanjing University of Aeronautics and Astronautics, China</p>
</fn>
<corresp id="c001">&#x2a;Correspondence: Le Cai, <email>earcle@yeah.net</email>
</corresp>
<fn fn-type="other">
<p>This article was submitted to Advanced Clean Fuel Technologies, a section of the journal Frontiers in Energy Research</p>
</fn>
</author-notes>
<pub-date pub-type="epub">
<day>21</day>
<month>09</month>
<year>2022</year>
</pub-date>
<pub-date pub-type="collection">
<year>2022</year>
</pub-date>
<volume>10</volume>
<elocation-id>989883</elocation-id>
<history>
<date date-type="received">
<day>09</day>
<month>07</month>
<year>2022</year>
</date>
<date date-type="accepted">
<day>05</day>
<month>09</month>
<year>2022</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2022 Liu, Cai, Xu, Fu and Wang.</copyright-statement>
<copyright-year>2022</copyright-year>
<copyright-holder>Liu, Cai, Xu, Fu and Wang</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<p>The effect of boundary layer oscillating suction (BLOS) on the vortex structure of high-load linear compressor cascades is studied by a high-fidelity numerical calculation. The oscillation parameters (amplitude and frequency) and suction control parameters (suction position and mass flow) are continuously adjusted. It was found that higher aerodynamic efficiency could be obtained with suitable oscillation parameters and suction control parameters. This is achieved because BLOS not only absorbs the low-energy fluid in the boundary layer but also optimizes the vortex structure in the compressor passage.</p>
</abstract>
<kwd-group>
<kwd>compressor cascade</kwd>
<kwd>boundary layer</kwd>
<kwd>oscillating suction</kwd>
<kwd>separated flow control</kwd>
<kwd>vortex structure</kwd>
</kwd-group>
</article-meta>
</front>
<body>
<sec id="s1">
<title>1 Introduction</title>
<p>Viscous effects, non-constant flow properties, and inverse pressure gradients inside highly loaded compressors often cause complex separation flows and vortex structures. Suppressing the boundary layer separation is an important means to improve the performance of the compressor while reducing engine weight and increasing blade load. Basically, the average skin friction increasing in front can have an inhibitory effect on separation, which can be achieved through momentum transfer (<xref ref-type="bibr" rid="B7">Jahanmiri, 2010</xref>). In addition, more effective control can be obtained by introducing oscillatory momentum coupled with flow instabilities (<xref ref-type="bibr" rid="B16">Seifert et al., 1996</xref>). Momentum transfer is widely used for active separation control, such as synthetic jets (<xref ref-type="bibr" rid="B4">Guendogdu et al., 2008</xref>; <xref ref-type="bibr" rid="B14">Pawan et al., 2022</xref>; <xref ref-type="bibr" rid="B20">Sushanta and Shantanu, 2022</xref>), plasma drives (<xref ref-type="bibr" rid="B25">Zheng et al., 2014</xref>; <xref ref-type="bibr" rid="B6">Hamrin et al., 2018</xref>; <xref ref-type="bibr" rid="B11">Lee et al., 2020</xref>; <xref ref-type="bibr" rid="B22">Vytenis, 2020</xref>), boundary layer suction (<xref ref-type="bibr" rid="B13">Merchant, 2000</xref>; <xref ref-type="bibr" rid="B18">Song et al., 2005</xref>; <xref ref-type="bibr" rid="B5">G&#xfc;mmer et al., 2008</xref>; <xref ref-type="bibr" rid="B8">Kerrebrock et al., 2008</xref>; <xref ref-type="bibr" rid="B3">Dorfner et al., 2011</xref>; <xref ref-type="bibr" rid="B15">Schlaps et al., 2014</xref>; <xref ref-type="bibr" rid="B17">Siemann and Seume, 2015</xref>; <xref ref-type="bibr" rid="B24">Zhang et al., 2016</xref>), and jet streams (<xref ref-type="bibr" rid="B1">Culley et al., 2003a</xref>).</p>
<p>Prior to the concept of the boundary layer, Plante proposed a method to achieve separation control by sucking out the low-energy fluid inside the boundary layer. <xref ref-type="bibr" rid="B12">Loughery et al. (1971)</xref> systematically studied the effect of boundary layer suction on the performance of compressor cascades, and the results proved that suction could significantly improve the efficiency of the compressor. Before 1998, <xref ref-type="bibr" rid="B9">Kerrebrock et al. (1997)</xref> studied in detail the effect of suction in the fan, compressor rotor, and guide vane, and he finally designed a single-stage pressure ratio of 1.6 for the suction compressor. <xref ref-type="bibr" rid="B2">Culley et al. (2003b)</xref> conducted an experimental study on the boundary layer suction of the guide vane and showed that only 0.4% of the flow inside the passage needs to be suctioned to reduce the total pressure loss by 22%. Boundary layer suction control in a large bending angle compressor was experimentally investigated under transonic conditions by <xref ref-type="bibr" rid="B21">Vandeputte (2000)</xref>, and the results showed that a suction flow rate of 1.6% can effectively reduce the separation of the suction surface of the blade passage, weaken wake strength, and reduce the total pressure loss by about 65%.</p>
<p>There is no human intervention in the original boundary layer suction (BLS), but in fact it is difficult to guarantee the absolute constancy of the suction. The non-constant nature of the flow field itself always causes unsteady states, which is more evident in the flow field of a compressor machine. On this basis, Cai <xref ref-type="bibr" rid="B10">Le (2015)</xref> proposed the concept of boundary layer oscillating suction. He introduced a non-constant excitation in the suction process to make the mass flow change periodically and realized the non-constant control of suction by controlling the parameters. Boundary layer oscillating suction specifically refers to the non-constant process in which the suction flow rate oscillates periodically according to a sine or cosine function relationship. This study concentrates on the separation characteristics of the linear compressor blade flow field. We perform a comparative analysis for with and without aspiration. Different control effects of the steady and oscillatory suction on the separation region will be shown to get a reference for the optimal excitation parameters. The numerical study was set at an incidence angle of 11&#xb0; and an incoming Mach number of 0.22.</p>
<p>\This study is organized as follows: section 2 gives the numerical method used in this study, including blade geometry, boundary layer suction structure, and oscillatory parameters. This is the basis of all research. It also verifies the accuracy of the numerical calculation based on experimental results; section 3 analyzes the role of suction position, suction flow rate, and oscillatory control parameters on separation flow control by presenting the numerical calculation results. Various vortex identification methods and loss assessment methods are mentioned in this section; section 4 details a comprehensive presentation and clarifies the conclusions of this study. It provides a new idea for the next vortex active control method.</p>
</sec>
<sec id="s2">
<title>2 Numerical methods</title>
<sec id="s2-1">
<title>2.1 Geometric configuration</title>
<p>This study is based on the low-reaction compressor by <xref ref-type="bibr" rid="B23">Wang et al. (2007</xref>). The geometric and aerodynamic parameters of the blade are shown in <xref ref-type="table" rid="T1">Table 1</xref>, and the compressor cascade domain extracted from these parameters is given in <xref ref-type="fig" rid="F1">Figure 1</xref>. The two-dimensional grid forms a three-dimensional grid by base-stacking along the blade height direction. The suction slots simulated by the slices extracted from the blade surface are placed at different axial chord lengths from the leading edge. The normal velocity condition of the boundary is specified at the suction outlet. For the non-constant suction control, the suction velocity u(t) can be simulated as a combination of periodic parameters with constant velocity, which is written as <xref ref-type="disp-formula" rid="e1">Eq. 1</xref>:<disp-formula id="e1">
<mml:math id="m500">
<mml:mrow>
<mml:mi mathvariant="bold-italic">u</mml:mi>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mi mathvariant="bold-italic">t</mml:mi>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mi mathvariant="bold-italic">U</mml:mi>
<mml:mn mathvariant="bold">0</mml:mn>
</mml:msub>
<mml:mi mathvariant="bold">sin</mml:mi>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mn mathvariant="bold">2</mml:mn>
<mml:mi mathvariant="bold-italic">&#x3c0;</mml:mi>
<mml:mi mathvariant="bold-italic">f</mml:mi>
<mml:mi mathvariant="bold-italic">t</mml:mi>
<mml:mo>&#x2b;</mml:mo>
<mml:mi mathvariant="bold-italic">&#x3c6;</mml:mi>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mo>&#x2b;</mml:mo>
<mml:msub>
<mml:mi mathvariant="bold-italic">U</mml:mi>
<mml:mi mathvariant="bold-italic">s</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
<label>(1)</label>
</disp-formula>where U<sub>0</sub> represents the oscillating amplitude, <italic>f</italic> is frequency, and <inline-formula id="inf1">
<mml:math id="m2">
<mml:mrow>
<mml:mi>&#x3c6;</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> is the phase. U<sub>s</sub> is the velocity condition exerted on the steady aspiration, which was adjusted to ensure the time-averaged suction rate meets the requirement. The control parameters such as f and U<sub>0</sub> are adjusted to investigate their effects on separation control. The oscillation fluctuations are shown <xref ref-type="fig" rid="F2">Figure 2</xref>.</p>
<table-wrap id="T1" position="float">
<label>TABLE 1</label>
<caption>
<p>Compressor cascade geometry and inlet aerodynamic parameters.</p>
</caption>
<table>
<thead>
<tr>
<th colspan="2" align="left">Blade geometry</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">&#x2003;Chord</td>
<td align="left">95.8&#xa0;mm</td>
</tr>
<tr>
<td align="left">&#x2003;Solidity</td>
<td align="left">1.86</td>
</tr>
<tr>
<td align="left">&#x2003;Aspect ratio</td>
<td align="left">1.04</td>
</tr>
<tr>
<td align="left">&#x2003;Stagger angle</td>
<td align="left">6.5&#xb0;</td>
</tr>
<tr>
<td align="left">&#x2003;Blade inlet angle</td>
<td align="left">56.3&#xb0;</td>
</tr>
<tr>
<td align="left">&#x2003;Blade exit angle</td>
<td align="left">-8.7&#xb0;</td>
</tr>
<tr>
<td colspan="2" align="left">Inlet aerodynamic parameters</td>
</tr>
<tr>
<td align="left">&#x2003;Re<sub>1</sub>
</td>
<td align="left">5.12&#xd7;10<sup>5</sup>
</td>
</tr>
<tr>
<td align="left">&#x2003;Ma<sub>1</sub>
</td>
<td align="left">0.28</td>
</tr>
</tbody>
</table>
</table-wrap>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption>
<p>Schematic of blade geometry and computational domain.</p>
</caption>
<graphic xlink:href="fenrg-10-989883-g001.tif"/>
</fig>
<fig id="F2" position="float">
<label>FIGURE 2</label>
<caption>
<p>Periodic signal of the mass flow rate modeled by <xref ref-type="disp-formula" rid="e1">Eq. 1</xref>.</p>
</caption>
<graphic xlink:href="fenrg-10-989883-g002.tif"/>
</fig>
<p>The computational domain is discretized into approximately 1.15 million finite volumes in the form of HOH-type structural meshes. In order to have higher resolution near the solid walls, grid nodes are concentrated near the walls, leading and trailing edges, which ensures that the global y &#x2b; value is less than 5.</p>
<p>Flow fields for an analysis in this research are solved by ANSYS CFX v17.2. The second-order backward Euler method is used for time discretization, and the central difference JST scheme with suitable artificial viscosity achieves convective flow calculation with second-order accuracy. Approximation of the turbulent viscosity is carried out using a modified two-equation model RNG k-Epsilon, which will be compared with other models afterward.</p>
<p>For the incompressible flow problem in this study, the computational domain inlet is given in the total temperature, total pressure, and velocity directions. The inlet total pressure <inline-formula id="inf2">
<mml:math id="m3">
<mml:mrow>
<mml:msup>
<mml:mi>P</mml:mi>
<mml:mo>&#x2a;</mml:mo>
</mml:msup>
<mml:mo>&#x3d;</mml:mo>
<mml:mi>P</mml:mi>
<mml:mo>&#x2b;</mml:mo>
<mml:mrow>
<mml:mrow>
<mml:mi>&#x3c1;</mml:mi>
<mml:msup>
<mml:mover accent="true">
<mml:mi>U</mml:mi>
<mml:mo>&#x2192;</mml:mo>
</mml:mover>
<mml:mn>2</mml:mn>
</mml:msup>
</mml:mrow>
<mml:mo>/</mml:mo>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula>, where the values of static pressure <inline-formula id="inf3">
<mml:math id="m4">
<mml:mrow>
<mml:mi>P</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> and velocity <inline-formula id="inf4">
<mml:math id="m5">
<mml:mrow>
<mml:mover accent="true">
<mml:mi>U</mml:mi>
<mml:mo>&#x2192;</mml:mo>
</mml:mover>
</mml:mrow>
</mml:math>
</inline-formula> are calculated iteratively with the internal flow field; the subsonic flow outlet is given a pressure boundary condition to eliminate non-physical reflections; the blade and end wall surfaces are given a no-slip boundary condition <inline-formula id="inf5">
<mml:math id="m6">
<mml:mrow>
<mml:mover accent="true">
<mml:mi>V</mml:mi>
<mml:mo>&#x2192;</mml:mo>
</mml:mover>
<mml:mo>&#x22c5;</mml:mo>
<mml:mover accent="true">
<mml:mi>n</mml:mi>
<mml:mo>&#x2192;</mml:mo>
</mml:mover>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0</mml:mn>
</mml:mrow>
</mml:math>
</inline-formula>; and the pitch direction is given a periodic boundary condition <inline-formula id="inf6">
<mml:math id="m7">
<mml:mrow>
<mml:msub>
<mml:mi>&#x3d5;</mml:mi>
<mml:mi mathvariant="normal">a</mml:mi>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mi>&#x3d5;</mml:mi>
<mml:mrow>
<mml:mi>a</mml:mi>
<mml:mo>&#x2b;</mml:mo>
<mml:mi>&#x394;</mml:mi>
<mml:mi>&#x3b8;</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>, where <inline-formula id="inf7">
<mml:math id="m8">
<mml:mrow>
<mml:mi>&#x3d5;</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> is the value of the variable and <inline-formula id="inf8">
<mml:math id="m9">
<mml:mrow>
<mml:mi>&#x3b8;</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> is the period. To maintain the free stream Mach number of 0.24&#xa0;at various incidences, the value of the pressure outlet can be adjusted.</p>
<p>Unsteady calculations are achieved by adding virtual time steps. Based on the intense unsteadiness and three-dimensionality in the compressor passage flow, a uniform time step of 1.0 &#xd7; 10&#x2013;5 has been set in the computation. The CFL numbers led by this configuration are controlled within 5.0. All the unsteady calculations use the results of steady calculations as the initial condition.</p>
</sec>
<sec id="s2-2">
<title>2.2 Numerical validation</title>
<p>This section is the validation of numerical calculation. We use the data provided by <xref ref-type="bibr" rid="B19">Soria and Cantwell (1993</xref>) as criteria to validate the numerical calculation configuration. The experimental parameters are shown in <xref ref-type="table" rid="T2">Table 2</xref>. During the numerical calculation of the high-load compressor, large-scale separated flow is bound to exist, and in order to be able to accurately describe the three-dimensional flow structure, the numerical parameter configurations in this study are set strictly based on the results of the numerical calculation calibration. These include the number of meshes, wall y &#x2b; values, and the time and spatial discrete schemes.</p>
<table-wrap id="T2" position="float">
<label>TABLE 2</label>
<caption>
<p>Compressor cascade geometry and inlet aerodynamic parameters documented by <xref ref-type="bibr" rid="B12">Loughery et al. (1971</xref>).</p>
</caption>
<table>
<thead>
<tr>
<th colspan="2" align="left">Blade geometry</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">Chord</td>
<td align="left">120&#xa0;mm</td>
</tr>
<tr>
<td align="left">Solidity</td>
<td align="left">1.28</td>
</tr>
<tr>
<td align="left">Aspect ratio</td>
<td align="left">1.3</td>
</tr>
<tr>
<td align="left">Stagger angle</td>
<td align="left">15.3&#xb0;</td>
</tr>
<tr>
<td align="left">Blade inlet angle</td>
<td align="left">40&#xb0;</td>
</tr>
<tr>
<td align="left">Blade exit angle</td>
<td align="left">100&#xb0;</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>The choice of turbulence is first examined. As shown in <xref ref-type="fig" rid="F3">Figure 3B</xref>, the spanwise distribution of the pitch-averaged total pressure loss coefficient (defined by <xref ref-type="disp-formula" rid="e2">Eq. 2</xref>) calculated with the RNG k-Epsilon model matches better with the experimental data than other models. The comparison of the total pressure loss coefficient and the outlet Mach number is shown in <xref ref-type="fig" rid="F4">Figure 4A, B</xref>, respectively, which can prove the accuracy of the numerical calculation results. In the spatial dimension <xref ref-type="fig" rid="F3">Figure 3A</xref>, the separation topology, such as the onset and extent of the corner separation region, captured by ink flow visualization in the experiment, is remarkably predicted by the numerical results. Therefore, the present numerical configuration is reliable for revealing the flow characteristics in a high-load cascade.<disp-formula id="e2">
<mml:math id="m10">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3c9;</mml:mi>
<mml:mn mathvariant="bold-italic">2</mml:mn>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:msubsup>
<mml:mi mathvariant="bold-italic">p</mml:mi>
<mml:mn mathvariant="bold-italic">1</mml:mn>
<mml:mo>&#x2a;</mml:mo>
</mml:msubsup>
<mml:mo>&#x2212;</mml:mo>
<mml:msubsup>
<mml:mi mathvariant="bold-italic">p</mml:mi>
<mml:mn mathvariant="bold-italic">2</mml:mn>
<mml:mo>&#x2a;</mml:mo>
</mml:msubsup>
</mml:mrow>
<mml:mrow>
<mml:msubsup>
<mml:mi mathvariant="bold-italic">p</mml:mi>
<mml:mn mathvariant="bold-italic">1</mml:mn>
<mml:mo>&#x2a;</mml:mo>
</mml:msubsup>
<mml:mo>&#x2212;</mml:mo>
<mml:msub>
<mml:mi mathvariant="bold-italic">p</mml:mi>
<mml:mn mathvariant="bold-italic">1</mml:mn>
</mml:msub>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:math>.<label>(2)</label>
</disp-formula>
</p>
<fig id="F3" position="float">
<label>FIGURE 3</label>
<caption>
<p>Validation of the 3-D simulation model. <bold>(A)</bold> Limiting stream lines of CFD and experimental results; <bold>(B)</bold> the spanwise distribution of total pressure loss coefficient at outlet.</p>
</caption>
<graphic xlink:href="fenrg-10-989883-g003.tif"/>
</fig>
<fig id="F4" position="float">
<label>FIGURE 4</label>
<caption>
<p>Total pressure loss coefficient and Mach number comparison. <bold>(A)</bold> Total pressure loss coefficient; <bold>(B)</bold> Mach Number.</p>
</caption>
<graphic xlink:href="fenrg-10-989883-g004.tif"/>
</fig>
<p>The grid independence is investigated to ensure reasonability of the numerical configuration used in the current study. <xref ref-type="fig" rid="F5">Figure 5</xref> presents the variation of the total pressure loss coefficient with respect to the total grid numbers. The results show that further refinements (grid number larger than 1.15 million) of grids leads to less than 0.5% difference of loss coefficients, which indicates the consistency of the current simulations with respect to the variation of grid resolution.</p>
<fig id="F5" position="float">
<label>FIGURE 5</label>
<caption>
<p>Grid independent validation of 3-D simulation.</p>
</caption>
<graphic xlink:href="fenrg-10-989883-g005.tif"/>
</fig>
</sec>
</sec>
<sec sec-type="results|discussion" id="s3">
<title>3 Results and discussion</title>
<p>A detailed numerical analysis of the oscillation parameters and suction control parameters is presented in this section. Changes of the oscillating aspiration on the structure of the vortex are also investigated in depth. For a more accurate representation of the flow field structure, the Q-criterion, absolute value of the vorticity <inline-formula id="inf9">
<mml:math id="m11">
<mml:mrow>
<mml:mi>&#x3a9;</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>, dissipation function <inline-formula id="inf10">
<mml:math id="m12">
<mml:mrow>
<mml:mi>&#x3a9;</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>, and the total pressure loss coefficient <inline-formula id="inf11">
<mml:math id="m13">
<mml:mrow>
<mml:mi mathvariant="bold-italic">&#x3c9;</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> are introduced.</p>
<p>Vorticity <inline-formula id="inf12">
<mml:math id="m14">
<mml:mrow>
<mml:mi>&#x3a9;</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> expresses the rotational velocity of the fluid, which can be calculated using the following <xref ref-type="disp-formula" rid="e3">Eq. 3</xref>:<disp-formula id="e3">
<mml:math id="m85">
<mml:mrow>
<mml:mi mathvariant="bold-italic">&#x3a9;</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mo>&#x2207;</mml:mo>
<mml:mo>&#xd7;</mml:mo>
<mml:mi mathvariant="bold-italic">V</mml:mi>
<mml:mo>,</mml:mo>
</mml:mrow>
</mml:math>
<label>(3)</label>
</disp-formula>
</p>
<p>where Q-criterion is used to identify vortex structures. Q is the second matrix invariant of the velocity gradient, which can be calculated using the following <xref ref-type="disp-formula" rid="e4">Eq. 4</xref>:<disp-formula id="e4">
<mml:math id="m16">
<mml:mrow>
<mml:mi mathvariant="bold-italic">Q</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mn mathvariant="bold">1</mml:mn>
</mml:mrow>
<mml:mrow>
<mml:mn mathvariant="bold">2</mml:mn>
</mml:mrow>
</mml:mfrac>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mo>&#x2225;</mml:mo>
<mml:mi mathvariant="bold">&#x3a9;</mml:mi>
<mml:mo>&#x2225;</mml:mo>
</mml:mrow>
<mml:mn mathvariant="bold">2</mml:mn>
</mml:msup>
<mml:mo>&#x2212;</mml:mo>
<mml:msup>
<mml:mrow>
<mml:mo>&#x2225;</mml:mo>
<mml:mi mathvariant="bold-italic">S</mml:mi>
<mml:mo>&#x2225;</mml:mo>
</mml:mrow>
<mml:mn mathvariant="bold">2</mml:mn>
</mml:msup>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:math>.<label>(4)</label>
</disp-formula>
</p>
<p>It can be seen that <inline-formula id="inf13">
<mml:math id="m17">
<mml:mrow>
<mml:mi>Q</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> is a function which contains the angular velocity tensor <inline-formula id="inf14">
<mml:math id="m18">
<mml:mrow>
<mml:mi>&#x3a9;</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> and the strain rate tensor <inline-formula id="inf15">
<mml:math id="m19">
<mml:mrow>
<mml:mi>S</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>, and operator <inline-formula id="inf16">
<mml:math id="m20">
<mml:mrow>
<mml:mo>&#x2225;</mml:mo>
<mml:mo>&#x2225;</mml:mo>
</mml:mrow>
</mml:math>
</inline-formula> represents the Euclide norm. The magnitude of <inline-formula id="inf17">
<mml:math id="m21">
<mml:mrow>
<mml:mi>Q</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> represents the relationship between rotation and deformation in the flow passage. Based on the experience gained during this study, Q insists on giving preference to methods based on vorticity or streamlines in vortex identification.</p>
<p>The entropy production of turbomachinery can be divided into two parts: dissipative entropy production and heat transfer entropy production. The dissipation function <inline-formula id="inf18">
<mml:math id="m22">
<mml:mrow>
<mml:mi>&#x3a6;</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> can be obtained through entropy transport <xref ref-type="disp-formula" rid="e5">Eq. 5</xref>. It can be used to describe the sources of loss inside the passage.<disp-formula id="e5">
<mml:math id="m23">
<mml:mrow>
<mml:mi mathvariant="bold-italic">T</mml:mi>
<mml:mfrac>
<mml:mrow>
<mml:mi mathvariant="bold-italic">D</mml:mi>
<mml:mi mathvariant="bold-italic">s</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi mathvariant="bold-italic">d</mml:mi>
<mml:mi mathvariant="bold-italic">t</mml:mi>
</mml:mrow>
</mml:mfrac>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mi mathvariant="bold-italic">D</mml:mi>
<mml:mi mathvariant="bold-italic">q</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi mathvariant="bold-italic">d</mml:mi>
<mml:mi mathvariant="bold-italic">t</mml:mi>
</mml:mrow>
</mml:mfrac>
<mml:mo>&#x2b;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mi mathvariant="bold">&#x3a6;</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi mathvariant="bold-italic">&#x3c1;</mml:mi>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:math>
<label>(5)</label>
</disp-formula>
</p>
<sec id="s3-1">
<title>3.1 Influences of excitation parameters on control effects</title>
<sec id="s3-1-1">
<title>3.1.1 The effect of excitation amplitudes</title>
<p>
<xref ref-type="fig" rid="F6">Figure 6</xref> shows the variation of the total pressure loss coefficient with excitation amplitude. Both situations with <italic>f</italic> &#x3d; 417&#xa0;Hz and <italic>f</italic> &#x3d; 1,000&#xa0;Hz are considered here. The total pressure loss reaches 0.106 when &#x394;m<sub>s</sub> &#x3d; 0.0, the BLS case. It can be seen that only when the excitation amplitude exceeds the threshold value of 0.2 does it have a significant positive effect on cascade performance. Optimal control is achieved in the following ranges from &#x394;m<sub>s</sub> &#x3d; 0.316 to &#x394;m<sub>s</sub> &#x3d; 0.7, with the maximum loss reduction approaching 8.42% for the case of <italic>f</italic> &#x3d; 417&#xa0;Hz. The change in frequencies, from 417 to 1,000&#xa0;Hz, also affects the control effect, which can be concluded from the narrowed optimal region. It should be noticed that, beyond the optimal amplitudes, the control effects tend to deteriorate in both cases. Because of the inevitable introduction of additional viscous dissipation into the flow field, led by mass flow oscillation in the BLOS case, excessive increase in excitation amplitudes gives rise to more viscous loss and hence weakens the overall control effects.</p>
<fig id="F6" position="float">
<label>FIGURE 6</label>
<caption>
<p>Distribution of total pressure loss according to the oscillation amplitude in the control of BLOS (0.39 <inline-formula id="inf19">
<mml:math id="m24">
<mml:mrow>
<mml:mover accent="true">
<mml:mi mathvariant="bold-italic">Z</mml:mi>
<mml:mo>&#xaf;</mml:mo>
</mml:mover>
</mml:mrow>
</mml:math>
</inline-formula>, m<sub>s</sub> &#x3d; 1.77%, &#x3b1; &#x3d; 25<sup>o</sup>, i &#x3d; 0<sup>o</sup>).</p>
</caption>
<graphic xlink:href="fenrg-10-989883-g006.tif"/>
</fig>
<p>The enhanced performance is indicative of promoted flow fields, which could be detected from flow topologies visualized by iso-surfaces of Q-value in <xref ref-type="fig" rid="F7">Figure 7</xref>. In the BLS case <xref ref-type="fig" rid="F7">Figure 7A</xref>, the separation vortices bearing the appearances of layer structures on the suction surface stably resides in the corner regions near the end walls. As the excitation amplitude approaches 5.98%, the layer-shaped separation vortices are forced to break down near the trailing edge, which can be attributed to the introduced unsteady effects by periodical oscillation in aspirating flow rates. Furthermore, the increased amplitudes, between 48.71 and 82.91%, tend to intensify the unsteady actuation in the separation vortices. The substantial change in the vortex structure due to BLOS is manifested in the splitting of the steady laminar separated vortex into a series of vortex tubes. These vortex tubes are simultaneously swept up by the lateral secondary flow near the end wall, forming a donut-like structure, and then periodically shed into the wake, which inevitably causes significant periodic oscillations in the flow field, thereby restoring the instability that the fluid inherently possesses.</p>
<fig id="F7" position="float">
<label>FIGURE 7</label>
<caption>
<p>Instantaneous vortex structures of the cascade in the control with different oscillation amplitudes (Q &#x3d; <inline-formula id="inf20">
<mml:math id="m25">
<mml:mrow>
<mml:mn mathvariant="bold">2</mml:mn>
<mml:mo>&#xd7;</mml:mo>
<mml:msup>
<mml:mn mathvariant="bold">10</mml:mn>
<mml:mn mathvariant="bold">6</mml:mn>
</mml:msup>
</mml:mrow>
</mml:math>
</inline-formula>, 0.39 <inline-formula id="inf21">
<mml:math id="m26">
<mml:mrow>
<mml:mover accent="true">
<mml:mi mathvariant="bold-italic">Z</mml:mi>
<mml:mo>&#xaf;</mml:mo>
</mml:mover>
</mml:mrow>
</mml:math>
</inline-formula>, m<sub>s</sub> &#x3d; 1.77%, f &#x3d; 1,000&#xa0;Hz, &#x3b1; &#x3d; 25<sup>o</sup>, i &#x3d; 0<sup>o</sup>). <bold>(A)</bold> &#x394;m<sub>s</sub> &#x3d; 0.00%, BLS; <bold>(B)</bold> &#x394;m<sub>s</sub> &#x3d; 5.98%, BLOS; <bold>(C)</bold> &#x394;m<sub>s</sub> &#x3d; 48.71%, BLOS; and <bold>(D)</bold> &#x394;m<sub>s</sub> &#x3d; 82.91%, BLOS.</p>
</caption>
<graphic xlink:href="fenrg-10-989883-g007.tif"/>
</fig>
<p>It is the spatiotemporal alteration in vortical structures that distinguishes the control effects in the BLS and BLOS cases. More detailed discussions about the transformed separation topology and related performance variation will be presented subsequently.</p>
</sec>
<sec id="s3-1-2">
<title>3.1.2 The effect of excitation frequencies</title>
<p>The effect of another key control parameter, i.e., frequency on the control effect was investigated with an excitation amplitude of 48.71%. The variation of temporal-averaged total pressure loss coefficient is plotted in <xref ref-type="fig" rid="F8">Figure 8</xref>. The uncontrolled case is used as a reference and is represented as a red circular solid dot in the aforementioned figure. The BLS and BLOS methods greatly improve the cascade performance by effectively mitigating large-scale separation in the uncontrolled flow field. The benefits of stabilized suction have been extensively documented in previous studies. The introduction of oscillations in the suction stream can further reduce losses within a certain optimal bandwidth. As labelled by red circular rings in <xref ref-type="fig" rid="F8">Figure 8</xref>, the most effective controls are achieved in the range of <italic>f</italic> &#x3d; 295&#xa0;Hz through <italic>f</italic> &#x3d; 1,326&#xa0;Hz, with the maximum relative loss reduction approaching 20.5% of that in the BLS case. Beyond this range, the BLOS method no longer shows great advantages over the BLS method. This relative wide effective excitation bandwidth, discovered currently, indicates a large tolerance for choosing excitation frequencies in practical applications.</p>
<fig id="F8" position="float">
<label>FIGURE 8</label>
<caption>
<p>Distribution of total pressure loss according to the oscillation frequency in the control of BLOS (0.39 <inline-formula id="inf22">
<mml:math id="m27">
<mml:mrow>
<mml:mover accent="true">
<mml:mi mathvariant="bold-italic">Z</mml:mi>
<mml:mo>&#xaf;</mml:mo>
</mml:mover>
</mml:mrow>
</mml:math>
</inline-formula>, ms &#x3d; 1.77%, &#x394;m<sub>s</sub> &#x3d; 48.71%, &#x3b1; &#x3d; 25<sup>o</sup>, i &#x3d; 0<sup>o</sup>).</p>
</caption>
<graphic xlink:href="fenrg-10-989883-g008.tif"/>
</fig>
<p>The temporal features of controlled flow fields with various excitation frequencies are revealed in <xref ref-type="table" rid="T3">Table 3</xref>. The five monitor points are placed at the streamwise location shown in <xref ref-type="fig" rid="F1">Figure 1</xref> and evenly distributed from 10 to 90% span. The time histories of total pressure captured by these monitor points are processed <italic>via</italic> fast Fourier transformation to extract the characteristic frequencies. As shown in the aforementioned table, the main frequencies captured in the flow field are in line with the excitation frequencies, which indicates that the unsteady properties in BLOS controlled flow fields are fully restrained by the oscillating aspiration flow rate. Furthermore, it could be argued that active flow control methods always have the tendency to impose some of their inherent physical properties on the flow field by means of mass, momentum, or energy exchange.</p>
<table-wrap id="T3" position="float">
<label>TABLE 3</label>
<caption>
<p>Spectrum graph of total pressure with different excitation frequencies.</p>
</caption>
<table>
<thead>
<tr>
<th align="left">
<italic>f</italic>
<sub>
<italic>excit</italic>
</sub>
</th>
<th colspan="5" align="left">
<italic>f</italic>
<sub>
<italic>monitor</italic>
</sub> (Hz)</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left"/>
<td align="left">10% <italic>H</italic>
</td>
<td align="left">30% <italic>H</italic>
</td>
<td align="left">50% <italic>H</italic>
</td>
<td align="left">70% <italic>H</italic>
</td>
<td align="left">90% <italic>H</italic>
</td>
</tr>
<tr>
<td align="left">147</td>
<td align="char" char=".">147</td>
<td align="char" char=".">147</td>
<td align="char" char=".">147</td>
<td align="char" char=".">147</td>
<td align="char" char=".">147</td>
</tr>
<tr>
<td align="left">417</td>
<td align="char" char=".">417</td>
<td align="char" char=".">417</td>
<td align="char" char=".">417</td>
<td align="char" char=".">417</td>
<td align="char" char=".">417</td>
</tr>
<tr>
<td align="left">736</td>
<td align="char" char=".">736</td>
<td align="char" char=".">736</td>
<td align="char" char=".">736</td>
<td align="char" char=".">736</td>
<td align="char" char=".">736</td>
</tr>
<tr>
<td align="left">884</td>
<td align="char" char=".">884</td>
<td align="char" char=".">884</td>
<td align="char" char=".">884</td>
<td align="char" char=".">884</td>
<td align="char" char=".">884</td>
</tr>
<tr>
<td align="left">1,178</td>
<td align="char" char=".">1,178</td>
<td align="char" char=".">1,178</td>
<td align="char" char=".">1,178</td>
<td align="char" char=".">1,178</td>
<td align="char" char=".">1,178</td>
</tr>
<tr>
<td align="left">1,326</td>
<td align="char" char=".">1,326</td>
<td align="char" char=".">1,326</td>
<td align="char" char=".">1,326</td>
<td align="char" char=".">1,326</td>
<td align="char" char=".">1,326</td>
</tr>
<tr>
<td align="left">1,767</td>
<td align="char" char=".">1767</td>
<td align="char" char=".">1767</td>
<td align="char" char=".">1767</td>
<td align="char" char=".">1767</td>
<td align="char" char=".">1767</td>
</tr>
<tr>
<td align="left">1,915</td>
<td align="char" char=".">1915</td>
<td align="char" char=".">1915</td>
<td align="char" char=".">1915</td>
<td align="char" char=".">1915</td>
<td align="char" char=".">1915</td>
</tr>
<tr>
<td align="left">2,062</td>
<td align="char" char=".">2062</td>
<td align="char" char=".">2062</td>
<td align="char" char=".">2062</td>
<td align="char" char=".">2062</td>
<td align="char" char=".">2062</td>
</tr>
<tr>
<td align="left">2,209</td>
<td align="char" char=".">2,209</td>
<td align="char" char=".">2,209</td>
<td align="char" char=".">2,209</td>
<td align="char" char=".">2,209</td>
<td align="char" char=".">2,209</td>
</tr>
<tr>
<td align="left">2,357</td>
<td align="char" char=".">2,357</td>
<td align="char" char=".">2,357</td>
<td align="char" char=".">2,357</td>
<td align="char" char=".">2,357</td>
<td align="char" char=".">2,357</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
</sec>
<sec id="s3-2">
<title>3.2 The response of effects to varied suction arrangement</title>
<p>An initial understanding about the process of boundary layer oscillation aspiration controlling a separation flow, especially the introduction of unsteady effect into the flow, is established in the previous section. The advantages possessed by BLOS over BLS in the control effects have also been proven to some extent. In this part, we perform further comparative investigations between BLS and BLOS on their susceptibility to varying operating conditions containing various suction flow rate, incidences, and suction locations.</p>
<sec id="s3-2-1">
<title>3.2.1 The response to the mass flow rate of aspirations</title>
<p>The fundamental physical mechanism behind the boundary layer suction technique is to remove the low-energy fluid within the boundary layers. Achieving the most effective control at the lowest cost, mostly the aspirating flow rate, is always pursued, which can lead to the least impact on the main flow in cascades. In <xref ref-type="fig" rid="F9">Figure 9</xref>, the performance variations with increasing aspirating flow rates for both BLS and BLOS cases are presented. In both cases, the suction control fails until the flow rate exceeds 1%. Afterward, both the control methods improve the performance of the cascade, with the BLOS method showing an advantage, with the largest relative loss reduction being 15.77% of that in the BLS case. This indicates that oscillatory suction is more effective than steady suction in controlling the separation flow at the same flow rate, or, from another point of view, the BLOS method can achieve the same control as the BLS case with a low suction flow rate.</p>
<fig id="F9" position="float">
<label>FIGURE 9</label>
<caption>
<p>Distribution of time-averaged total pressure loss by the time-averaged suction mass flow in the control of BLOS and BLS.</p>
</caption>
<graphic xlink:href="fenrg-10-989883-g009.tif"/>
</fig>
</sec>
<sec id="s3-2-2">
<title>3.2.2 The response to aspiration locations</title>
<p>To illustrate the influences of aspiration locations on the control processes, the performance variations for both BLS and BLOS cases with some selected parameters are shown in <xref ref-type="fig" rid="F10">Figure 10</xref>. It can be observed that the effects led by the BLS method bear great sensitivity to the locations from <xref ref-type="fig" rid="F10">Figure 10A</xref>. The enhancements only occur in a narrow location range of <inline-formula id="inf23">
<mml:math id="m28">
<mml:mrow>
<mml:msub>
<mml:mi>Z</mml:mi>
<mml:mi>s</mml:mi>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0.33</mml:mn>
</mml:mrow>
</mml:math>
</inline-formula> through <inline-formula id="inf24">
<mml:math id="m29">
<mml:mrow>
<mml:msub>
<mml:mi>Z</mml:mi>
<mml:mi>s</mml:mi>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0.48</mml:mn>
</mml:mrow>
</mml:math>
</inline-formula> when the aspiration flow rate is equal to 1.77%. In addition, even in this narrow range, the control effects vary obviously with different values of <inline-formula id="inf25">
<mml:math id="m30">
<mml:mrow>
<mml:msub>
<mml:mi>Z</mml:mi>
<mml:mi>s</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>. Further increasing the suction flow rate to 2.26% results in slight extension in the effective range. As the incidence is increased to 2 in <xref ref-type="fig" rid="F10">Figure 10B</xref>, the effective control could only be realized at <inline-formula id="inf26">
<mml:math id="m31">
<mml:mrow>
<mml:msub>
<mml:mi>Z</mml:mi>
<mml:mi>s</mml:mi>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0.39</mml:mn>
</mml:mrow>
</mml:math>
</inline-formula> for the BLS cases. This indicates that the sensitivity of BLS control to locations is intensified at off-design conditions. The similar conclusion to that widely documented in previous research studies could be drawn that it is the dramatic sensitivity to geometric suction configurations that significantly prohibits the boundary layer aspiration technology from practical applications in engineering.</p>
<fig id="F10" position="float">
<label>FIGURE 10</label>
<caption>
<p>Distribution of time averaged total pressure loss according to the suction location in the control of BLOS and BLS. <bold>(A)</bold> m<sub>s</sub> &#x3d; 1.77%, i &#x3d; 0<sup>o</sup> and <bold>(B)</bold> m<sub>s</sub> &#x3d; 2.26%, i &#x3d; 2<sup>o</sup>.</p>
</caption>
<graphic xlink:href="fenrg-10-989883-g010.tif"/>
</fig>
<p>On contrast, the BLOS method gives rise to suppression on the sensitivity of control effects to suction locations, which can be verified by the extended location range of <inline-formula id="inf27">
<mml:math id="m32">
<mml:mrow>
<mml:msub>
<mml:mi>Z</mml:mi>
<mml:mi>s</mml:mi>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0.2</mml:mn>
</mml:mrow>
</mml:math>
</inline-formula> through <inline-formula id="inf28">
<mml:math id="m33">
<mml:mrow>
<mml:msub>
<mml:mi>Z</mml:mi>
<mml:mi>s</mml:mi>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0.66</mml:mn>
</mml:mrow>
</mml:math>
</inline-formula> presented in <xref ref-type="fig" rid="F10">Figure 10A</xref>. Meanwhile, the loss reductions in this region are close in value, indicating robustness in the control effects owned by the BLOS method. In addition, it is worth noting that a wider effective range can be achieved at a lower suction flow rate <italic>via</italic> the BLOS method (m &#x3d; 1.77%) than that <italic>via</italic> the BLS method (m &#x3d; 2.26%). Also, at off-design conditions, the less exaggerated sensitivity of the control effect, reflected by a wider effective range from <inline-formula id="inf29">
<mml:math id="m34">
<mml:mrow>
<mml:msub>
<mml:mi>Z</mml:mi>
<mml:mi>s</mml:mi>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0.39</mml:mn>
</mml:mrow>
</mml:math>
</inline-formula> to <inline-formula id="inf30">
<mml:math id="m35">
<mml:mrow>
<mml:msub>
<mml:mi>Z</mml:mi>
<mml:mi>s</mml:mi>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0.57</mml:mn>
</mml:mrow>
</mml:math>
</inline-formula> in <xref ref-type="fig" rid="F10">Figure 10B</xref>, repeatedly demonstrates the advantages of the BLOS method.</p>
<p>Another issue considered currently is to exclude the possibility that the aforementioned advantages of the BLOS method are resulted from the instantaneous increase in the suction flow rate during a half-oscillation period. Thus, in <xref ref-type="fig" rid="F10">Figure 10A</xref>, we additionally present a BLS result with a suction flow rate equal to 2.63%, which is the peak value of the sinusoidally varied suction flow rate in BLOS. The result turns out that this BLS configuration still not only fails to effectively improve the performance to the same extent as the BLOS case, but even worsens the performance globally. The resultant conclusion could be drawn that the introduction of unsteady effects by the oscillating suction flow rate is the main cause of the superiority possessed by the BLOS method to the BLS one.</p>
<p>The different spatiotemporal alterations of separation structures for the BLS and BLOS cases are examined subsequently. The flow fields of cases, as labelled by dashed circles, with <inline-formula id="inf31">
<mml:math id="m36">
<mml:mrow>
<mml:msub>
<mml:mi>Z</mml:mi>
<mml:mi>s</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> &#x3d; 0.27, 0.33, and 0.39 in <xref ref-type="fig" rid="F10">Figure 10A</xref>, are selected to perform detailed analysis. The limiting streamlines on solid surfaces for selected cases are presented in <xref ref-type="fig" rid="F11">Figure 11</xref>. In the case with suction location being 0.27 axial chord length, the BLS method fails to effectively suppress large-scale separation on the suction surface. As a result, the cascade stall occurs throughout the entire span, giving rise to enormous losses. As the suction location moves downstream to 0.33 axial chord length, the BLS method starts to take effect by alleviating the cascade stall to the corner stall, which can be observed from the streamlines on both the suction surface and end walls. The flow topology in the BLS case becomes less severe when <inline-formula id="inf32">
<mml:math id="m37">
<mml:mrow>
<mml:msub>
<mml:mi>Z</mml:mi>
<mml:mi>s</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> &#x3d; 0.39, which bears resemblance to the corner separation topology. On the other hand, BLOS, in all the situations considered here, successfully prevents the cascade from stalling by reorganizing the vortical structures and hence maintaining the high performance in the critical load cascade. It should be pointed out that even though streamline topologies presented in both BLS and BLOS cases at <inline-formula id="inf33">
<mml:math id="m38">
<mml:mrow>
<mml:msub>
<mml:mi>Z</mml:mi>
<mml:mi>s</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> &#x3d; 0.39 are similar, the vortical structures literally differ from each other, which will be discussed in the following section.</p>
<fig id="F11" position="float">
<label>FIGURE 11</label>
<caption>
<p>Instantaneous limiting streamlines by different suction locations in the control of BLOS and BLS.</p>
</caption>
<graphic xlink:href="fenrg-10-989883-g011.tif"/>
</fig>
<p>The instantaneous vortical structures visualized in terms of Q iso-surfaces for selected cases are presented in <xref ref-type="fig" rid="F12">Figure 12</xref> in order to describe the entirely different vortical evolutions in the steadily and unsteadily controlled flow fields. The difference between the BLS and BLOS controlled flow fields manifests itself not in the structural transformations of the quasi-columnar vortices such as horse-shoe vortices and passage vortices but exclusively in the development of separation vortices on suction surfaces. In situations where the BLS method is adopted, the separation vortices on the suction surface show a relatively stable layer-shaped structure. The spatial extents of these structures shrink gradually as the control effects become strengthened from <inline-formula id="inf34">
<mml:math id="m39">
<mml:mrow>
<mml:msub>
<mml:mi>Z</mml:mi>
<mml:mi>s</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> &#x3d; 0.27 to <inline-formula id="inf35">
<mml:math id="m40">
<mml:mrow>
<mml:msub>
<mml:mi>Z</mml:mi>
<mml:mi>s</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> &#x3d; 0.39 and stably distributed in the corner regions. The reason for this transformation is that the BLS method removes the low-energy fluids within the boundary layer and improves its capacity of resisting inverse pressure gradients. In this way, the boundary layer is re-allocated and induces new separation vortices which are consequently stabilized under the influence of the &#x2018;steady properties&#x2019; possessed by the BLS method. The BLOS controlled fields under consideration here consistently exhibit a series of discretized ring-like vortices convecting downstream in the corner regions. Thus, it could be deduced that this vortical-ring street structure can benefit the tolerance of cascades against the varied operating conditions more than the conventional corner separation topologies in diffusion cascades.</p>
<fig id="F12" position="float">
<label>FIGURE 12</label>
<caption>
<p>Instantaneous vortex structures by different suction locations in the control of BLOS and BLS.</p>
</caption>
<graphic xlink:href="fenrg-10-989883-g012.tif"/>
</fig>
</sec>
</sec>
<sec id="s3-3">
<title>3.3 Spatiotemporal alterations in separation flows</title>
<p>The differences in performance improvement between BLS and BLOS are direct reflections of vortical alterations in flow fields which have been briefly described in the previous section. The relation between transformed separation topologies and performance enhancement is emphasized in this section in order to advance our knowledge about the main cause of the different control effects.</p>
<p>The results with <inline-formula id="inf36">
<mml:math id="m41">
<mml:mrow>
<mml:msub>
<mml:mi>Z</mml:mi>
<mml:mi>s</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> &#x3d; 0.33, ms &#x3d; 1.77% are under consideration. For the BLOS case, the frequency and amplitude are 1,000&#xa0;Hz and 48.71%, respectively. The vortical evolution and the accompanying loss distributions are analyzed according to contours plotted on the streamwise slices as shown in <xref ref-type="fig" rid="F13">Figures 13</xref> and <xref ref-type="fig" rid="F14">14</xref>.</p>
<fig id="F13" position="float">
<label>FIGURE 13</label>
<caption>
<p>Instantaneous vortex structure and loss of stream-wise observing section in the control of BLS.</p>
</caption>
<graphic xlink:href="fenrg-10-989883-g013.tif"/>
</fig>
<fig id="F14" position="float">
<label>FIGURE 14</label>
<caption>
<p>Instantaneous vortex structure and loss of stream-wise observing section in the control of BLOS.</p>
</caption>
<graphic xlink:href="fenrg-10-989883-g014.tif"/>
</fig>
<p>In the BLS controlled flow field, the layer-shaped separation vortices consistently possess high vorticity from the onset to the later evolutionary stage according to both <xref ref-type="fig" rid="F13">Figure 13</xref>(<inline-formula id="inf37">
<mml:math id="m42">
<mml:mrow>
<mml:mi>Q</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>) and (<inline-formula id="inf38">
<mml:math id="m43">
<mml:mrow>
<mml:mo>&#x7c;</mml:mo>
<mml:mrow>
<mml:mi>&#x3a9;</mml:mi>
</mml:mrow>
<mml:mo>&#x7c;</mml:mo>
</mml:mrow>
</mml:math>
</inline-formula>). This gives rise to significant local losses due to the strong shear stress (see <xref ref-type="fig" rid="F13">Figure 13</xref>(<inline-formula id="inf39">
<mml:math id="m44">
<mml:mrow>
<mml:mi>&#x3d5;</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>)) in the regions where they reside. A large amount of low-energy fluids is meanwhile confined in the regions enclosed by the separation vortices and solid walls. Also, these fluids lead to extremely high total pressure loss regions in the corners as shown in <xref ref-type="fig" rid="F13">Figure 13</xref>(<inline-formula id="inf40">
<mml:math id="m45">
<mml:mrow>
<mml:mi>&#x3c9;</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>). Thus, it could be concluded that in the BLS controlled flow field, the separation vortex consistently possesses high vortical strength, and the flow loss caused by it is the main source of the overall cascade loss.</p>
<p>For the BLOS case shown in <xref ref-type="fig" rid="F14">Figure 14</xref>, vortical alterations induce different distributions of aerodynamic quantities. From the vortical evolution (slice 1 to 3) shown in <xref ref-type="fig" rid="F14">Figure 14</xref>(<inline-formula id="inf41">
<mml:math id="m46">
<mml:mrow>
<mml:mi>Q</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>), it can be observed that the separation vortices are effectively discretized and roll up forming ring-shaped structures because of periodic excitation. In addition, the separation vortices are weakened in vorticity (see <xref ref-type="fig" rid="F14">Figure 14</xref>(<inline-formula id="inf42">
<mml:math id="m47">
<mml:mrow>
<mml:mo>&#x7c;</mml:mo>
<mml:mrow>
<mml:mi>&#x3a9;</mml:mi>
</mml:mrow>
<mml:mo>&#x7c;</mml:mo>
</mml:mrow>
</mml:math>
</inline-formula>)) and cause less local viscous dissipation as shown in <xref ref-type="fig" rid="F14">Figure 14</xref>(<inline-formula id="inf43">
<mml:math id="m48">
<mml:mrow>
<mml:mi>&#x3d5;</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>). The vortical transformation also shrinks the high-loss zones shown in <xref ref-type="fig" rid="F14">Figure 14</xref>(<inline-formula id="inf44">
<mml:math id="m49">
<mml:mrow>
<mml:mi>&#x3c9;</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>) indicating less low-energy fluids bounded within the separation vortices and meanwhile enhanced the cascade throughflow.</p>
<p>The aforementioned changes bring about significant reduction in pitch-averaged loss at the cascade outlet in the entire span as shown in <xref ref-type="fig" rid="F15">Figure 15A</xref>. In streamwise direction, the distribution of averaged total pressure loss presented in <xref ref-type="fig" rid="F15">Figure 15B</xref> reveals that the loss reduction takes place not only in the flow passage but also in the wake. Compared with the BLS case, the BLOS case causes a loss reduction of 17.5% at the trailing edge and 34.6% two axial chord lengths downstream the trailing edge. This denotes that the BLOS-induced vortex ring streets generate less viscous dissipation as convecting in the wake.</p>
<fig id="F15" position="float">
<label>FIGURE 15</label>
<caption>
<p>Span-wise distribution of pitch-averaged total pressure loss. <bold>(A)</bold> Stream-wise increase of overall mass-averaged total pressure loss and <bold>(B)</bold> in the outlet of cascade in the control with BLS and BLOS with the suction location of 0.33 <inline-formula id="inf45">
<mml:math id="m50">
<mml:mrow>
<mml:mover accent="true">
<mml:mi mathvariant="bold-italic">Z</mml:mi>
<mml:mo>&#xaf;</mml:mo>
</mml:mover>
</mml:mrow>
</mml:math>
</inline-formula>.</p>
</caption>
<graphic xlink:href="fenrg-10-989883-g015.tif"/>
</fig>
<p>Both the aspiration control methods are based on the effective removal of low-energy fluids. Moreover, the advantages possessed by the BLOS method in improving the cascade performance are achieved mainly through changing the layer-shaped separation vortices to the discretized donut-shaped vortex streets shedding into the wake. The benefits brought by the vortical transformation include (1) attenuated vorticity of separation vortices producing less local viscous dissipation; (2) narrowed blockage area trapping less low-energy fluids in the vicinity of corner regions; and (3) more energetic blockage fluids contributing to the mixing loss reduction in the wake.</p>
</sec>
</sec>
<sec id="s4">
<title>4 Conclusion remarks</title>
<p>Simulations of the flow of a three-dimensional linear high-load compressor cascade controlled by the BLS and BLOS methods were carried out. The effect of oscillation parameters on the control effect was parametrically investigated. In addition, a comparative analysis of the sensitivity of the BLS and BLOS methods to different operating conditions was carried out. This work was performed to understand the basic aerodynamics of unsteady suction for controlled flow separation.</p>
<sec id="s4-1">
<title>4.1 Control parameters</title>
<p>Oscillation amplitude and frequency are two crucial control parameters. The amplitude represents the energetic level of the unsteady excitation. Only when it exceeds a certain threshold can the BLOS method take effect, and in this study, the threshold value equals 0.31 approximately. However, due to the additional viscous dissipation introduced, excessive amplitudes weaken the control effect. A relative wide optimal frequency bandwidth within which the BLOS method surpasses the BLS method is detected in the current study. Also, in these situations, the characteristic frequency of the flow field is locked up to the excitation frequency.</p>
</sec>
<sec id="s4-2">
<title>4.2 Susceptibility to varying conditions</title>
<p>The BLOS method shows advantage over the BLS method on the control cost and the susceptibility to varying working conditions. With a fixed effective suction flow rate, the BLOS method can result in higher loss reduction. The variation in suction locations affects the BLOS controlled cascades less significantly than that with the BLS method. The operating range in terms of incidences is highly extended due to introduction of oscillation into the aspiration.</p>
</sec>
<sec id="s4-3">
<title>4.3 Flow structures</title>
<p>Oscillatory aspiration takes over the advantages of steady aspiration and further introduces structural reorganization in the flow field. The spatial transformation is mainly reflected in the discrete laminar separation vortex into a donut-shaped vortex street shedding to the wake flow. The vortical alteration leads to lower vorticity of separation vortices and hence decreases the viscous shear stress. The cascade blockage is also alleviated, indicating less low-energy fluids bounded in the corners. Furthermore, the donut-shaped vortex street contributes to the reduction in mixing loss in the wake.</p>
</sec>
</sec>
</body>
<back>
<sec sec-type="data-availability" id="s5">
<title>Data availability statement</title>
<p>The original contributions presented in the study are included in the article/Supplementary Material; further inquiries can be directed to the corresponding author.</p>
</sec>
<sec id="s6">
<title>Author contributions</title>
<p>BL completed most of the numerical simulation work and processed and analyzed the numerical results; LC proposed the method of boundary layer oscillating suction; HX jointly completed the analysis of the numerical simulation results; HF jointly completed part of the analysis of the results and drew part of the charts; and SW gave theoretical guidance to numerical simulation and result analysis.</p>
</sec>
<sec sec-type="COI-statement" id="s7">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec sec-type="disclaimer" id="s8">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors, and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ref-list>
<title>References</title>
<ref id="B1">
<citation citation-type="confproc">
<person-group person-group-type="author">
<name>
<surname>Culley</surname>
<given-names>D. E.</given-names>
</name>
<name>
<surname>Bright</surname>
<given-names>M. M.</given-names>
</name>
<name>
<surname>Prahst</surname>
<given-names>P. S.</given-names>
</name>
</person-group> (<year>2003</year>). &#x201c;<article-title>Active flow separation control of a stator vane using surface injection in a multistage compressor experiment</article-title>,&#x201d; in <conf-name>Proceedings ASME Turbo Expo 2003, collocated with the 2003 International Joint Power Generation Conference</conf-name>, <conf-loc>Atlanta, Georgia, USA</conf-loc>, <conf-date>February 4, 2009</conf-date> (<publisher-name>American Society of Mechanical Engineers</publisher-name>), <fpage>1039</fpage>&#x2013;<lpage>1050</lpage>. <pub-id pub-id-type="doi">10.1115/GT2003-38863</pub-id> </citation>
</ref>
<ref id="B2">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Culley</surname>
<given-names>D. E.</given-names>
</name>
<name>
<surname>Bright</surname>
<given-names>M. M.</given-names>
</name>
<name>
<surname>Prahst</surname>
<given-names>P. S.</given-names>
</name>
</person-group> (<year>2003</year>). <source>Active flow separation control of a stator vane using surface injection in a multistage compressor experiment</source>. <publisher-loc>Washington, DC</publisher-loc>: <publisher-name>ASME Paper</publisher-name>. </citation>
</ref>
<ref id="B3">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Dorfner</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Hergt</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Nicke</surname>
<given-names>E.</given-names>
</name>
</person-group> (<year>2011</year>). <article-title>Advanced nonaxisymmetric endwall contouring for axial compressors by generating an aerodynamic separator&#x2014;Part i: Principal cascade design and compressor application</article-title>. <source>ASME J. Turbomach.</source> <volume>133</volume>, <fpage>021026</fpage>. <pub-id pub-id-type="doi">10.1115/1.4001223</pub-id> </citation>
</ref>
<ref id="B4">
<citation citation-type="confproc">
<person-group person-group-type="author">
<name>
<surname>Guendogdu</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Vorreiter</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Seume</surname>
<given-names>J. R.</given-names>
</name>
</person-group> (<year>2008</year>). &#x201c;<article-title>Design of a low solidity flow-controlled stator with coanda surface in a high speed compressor</article-title>,&#x201d; in <conf-name>Proceeding ASME Turbo Expo 2008: Power for Land Sea, and Air</conf-name>, <conf-loc>Berlin Germany</conf-loc>, <conf-date>August 3 2009</conf-date> (<publisher-name>American Society of Mechanical Engineers</publisher-name>), <fpage>629</fpage>&#x2013;<lpage>639</lpage>. <pub-id pub-id-type="doi">10.1115/GT2008-51180</pub-id>
<volume>11</volume> </citation>
</ref>
<ref id="B5">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>G&#xfc;mmer</surname>
<given-names>V.</given-names>
</name>
<name>
<surname>Goller</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Swoboda</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2008</year>). <article-title>Numerical investigation of end wall boundary layer removal on highly loaded axial compressor blade rows</article-title>. <source>J. Turbomach.</source> <volume>130</volume> (<issue>1</issue>), <fpage>011015</fpage>. <pub-id pub-id-type="doi">10.1115/1.2749297</pub-id> </citation>
</ref>
<ref id="B6">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hamrin</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Gunell</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Lindkvist</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Lindqvist</surname>
<given-names>P.-A.</given-names>
</name>
<name>
<surname>Ergun</surname>
<given-names>R. E.</given-names>
</name>
<name>
<surname>Giles</surname>
<given-names>B. L.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Bow shock generator current systems: MMS observations of possible current closure</article-title>. <source>JGR. Space Phys.</source> <volume>123</volume> (<issue>1</issue>), <fpage>242</fpage>&#x2013;<lpage>258</lpage>. <pub-id pub-id-type="doi">10.1002/2017JA024826</pub-id> </citation>
</ref>
<ref id="B7">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Jahanmiri</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2010</year>). <source>Active flow control: A review</source>. <publisher-loc>Sweden</publisher-loc>: <publisher-name>Chalmers University of Technology</publisher-name>. </citation>
</ref>
<ref id="B8">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kerrebrock</surname>
<given-names>J. L.</given-names>
</name>
<name>
<surname>Epstein</surname>
<given-names>A. H.</given-names>
</name>
<name>
<surname>Merchant</surname>
<given-names>A. A.</given-names>
</name>
<name>
<surname>Guenette</surname>
<given-names>G. R.</given-names>
</name>
<name>
<surname>Parker</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Onnee</surname>
<given-names>J. F.</given-names>
</name>
<etal/>
</person-group> (<year>2008</year>). <article-title>Design and test of an aspirated counter-rotating fan</article-title>. <source>J. Turbomach.</source> <volume>130</volume> (<issue>2</issue>), <fpage>021004</fpage>. <pub-id pub-id-type="doi">10.1115/1.2776951</pub-id> </citation>
</ref>
<ref id="B9">
<citation citation-type="confproc">
<person-group person-group-type="author">
<name>
<surname>Kerrebrock</surname>
<given-names>J. L.</given-names>
</name>
<name>
<surname>Reijnen</surname>
<given-names>D. P.</given-names>
</name>
<name>
<surname>Ziminsky</surname>
<given-names>W. S.</given-names>
</name>
<name>
<surname>Smilg</surname>
<given-names>L. M.</given-names>
</name>
</person-group> (<year>1997</year>). &#x201c;<article-title>Aspirated compressors</article-title>,&#x201d; in <conf-name>Proceedings ASME 1997 International Gas Turbine and Aeroengine Congress and Exhibition</conf-name>, <conf-loc>Orlando Florida USA</conf-loc>, <conf-date>December 24, 2014</conf-date> (<publisher-name>American Society of Mechanical Engineers.</publisher-name>). <pub-id pub-id-type="doi">10.1115/97-GT-525</pub-id> </citation>
</ref>
<ref id="B10">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Le</surname>
<given-names>C.</given-names>
</name>
</person-group> (<year>2015</year>). <source>Investigation on separation structure and its steady &#x26; unsteady control in low reaction high load compressor cascade</source>. <publisher-loc>China</publisher-loc>: <publisher-name>Harbin Institute of Technology</publisher-name>. </citation>
</ref>
<ref id="B11">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lee</surname>
<given-names>M. U.</given-names>
</name>
<name>
<surname>Ji</surname>
<given-names>J.-Y.</given-names>
</name>
<name>
<surname>Yun</surname>
<given-names>G. S.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Cold-hot coupled waves in a flowing magnetized plasma</article-title>. <source>Nucl. Fusion</source> <volume>60</volume>, <fpage>126036</fpage>. <pub-id pub-id-type="doi">10.1088/1741-4326/abb61a</pub-id> </citation>
</ref>
<ref id="B12">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Loughery</surname>
<given-names>R. J.</given-names>
</name>
<name>
<surname>Horn</surname>
<given-names>R. A.</given-names>
</name>
<name>
<surname>Tramm</surname>
<given-names>P. C.</given-names>
</name>
</person-group> (<year>1971</year>). <source>Single stage experimental evaluation of boundary layer blowing and bleed techniques for high lift stator blades</source>. <publisher-loc>Washington, D.C.</publisher-loc>: <publisher-name>NASA CR-54573</publisher-name>. </citation>
</ref>
<ref id="B13">
<citation citation-type="confproc">
<person-group person-group-type="author">
<name>
<surname>Merchant</surname>
<given-names>A. A.</given-names>
</name>
</person-group> (<year>2000</year>). &#x201c;<article-title>Aerodynamic design and analysis of a high pressure ratio aspirated compressor stage</article-title>,&#x201d; in <conf-name>Proceeding ASME Turbo Expo 2000: Power for Land, Sea, and Air</conf-name>, <conf-loc>Munich, Germany</conf-loc>, <conf-date>August 4, 2014</conf-date> (<publisher-name>American Society of Mechanical Engineers.</publisher-name>), <fpage>10</fpage>. <pub-id pub-id-type="doi">10.1115/2000-GT-0619</pub-id> </citation>
</ref>
<ref id="B14">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pawan</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Santosh</surname>
<given-names>K. S.</given-names>
</name>
<name>
<surname>Harekrishna</surname>
<given-names>Y.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Experimental investigation of flow and thermal characteristics of synthetic jet issuing from sharp-edged orifices</article-title>. <source>Exp. Heat. Transf.</source> <volume>9</volume>, <fpage>1</fpage>&#x2013;<lpage>25</lpage>. <pub-id pub-id-type="doi">10.1080/08916152.2022.2105449</pub-id> </citation>
</ref>
<ref id="B15">
<citation citation-type="confproc">
<person-group person-group-type="author">
<name>
<surname>Schlaps</surname>
<given-names>R. C.</given-names>
</name>
<name>
<surname>Shahpar</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>G&#xfc;mmer</surname>
<given-names>V.</given-names>
</name>
</person-group> (<year>2014</year>). &#x201c;<article-title>Automatic three-dimensional optimisation of a modern tandem compressor Vane</article-title>,&#x201d; in <conf-name>Proceedings of ASME TURBO</conf-name>, <conf-date>2014</conf-date>, <conf-loc>D&#xfc;sseldorf Germany</conf-loc> (<publisher-name>ASME</publisher-name>). <pub-id pub-id-type="doi">10.13140/2.1.2633.6007</pub-id> </citation>
</ref>
<ref id="B16">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Seifert</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Darabi</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Wyganski</surname>
<given-names>I.</given-names>
</name>
</person-group> (<year>1996</year>). <article-title>Delay of airfoil stall by periodic excitation</article-title>. <source>J. Aircr.</source> <volume>33</volume> (<issue>4</issue>), <fpage>691</fpage>&#x2013;<lpage>698</lpage>. <pub-id pub-id-type="doi">10.2514/3.47003</pub-id> </citation>
</ref>
<ref id="B17">
<citation citation-type="confproc">
<person-group person-group-type="author">
<name>
<surname>Siemann</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Seume</surname>
<given-names>J. R.</given-names>
</name>
</person-group> (<year>2015</year>). &#x201c;<article-title>Design of an aspirated compressor stator by means of doe</article-title>,&#x201d; in <conf-name>Proceeding ASME Turbo Expo 2015: Turbine Technical Conference and Exposition</conf-name>, <conf-loc>Montreal Quebec Canada</conf-loc>, <conf-date>August 12, 2015</conf-date> (<publisher-name>American Society of Mechanical Engineers.</publisher-name>), <fpage>13</fpage>. <pub-id pub-id-type="doi">10.1115/GT2015-42474</pub-id> </citation>
</ref>
<ref id="B18">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Song</surname>
<given-names>Y. P.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Yang</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>Z. Q.</given-names>
</name>
</person-group> (<year>2005</year>). <source>A numerical investigation of boundary layer suction in compound lean compressor cascades. Turbine technical conference and exposition</source>. <publisher-loc>USA. New York</publisher-loc>: <publisher-name>ASME</publisher-name>. </citation>
</ref>
<ref id="B19">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Soria</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Cantwell</surname>
<given-names>B. J.</given-names>
</name>
</person-group> (<year>1993</year>). <article-title>Identification and classification of topological structures in free shear flows</article-title>. <source>Eddy Struct. Identif. Free Turbul. Shear Flows</source> <volume>21</volume>, <fpage>379</fpage>&#x2013;<lpage>390</lpage>. <pub-id pub-id-type="doi">10.1007/978-94-011-2098-2_31</pub-id> </citation>
</ref>
<ref id="B20">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sushanta</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Shantanu</surname>
</name>
</person-group> (<year>2022</year>). <article-title>Effects of the synthetic jet on the flow field and heat transfer over a surface-mounted square rib</article-title>. <source>Exp. Therm. Fluid Sci.</source> <volume>139</volume>, <fpage>110708</fpage>. <pub-id pub-id-type="doi">10.1016/j.expthermflusci.2022.110708</pub-id> </citation>
</ref>
<ref id="B21">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Vandeputte</surname>
<given-names>T. W.</given-names>
</name>
</person-group> (<year>2000</year>). <article-title>Effects of flow control on the aerodynamics of a tandem inlet guide vane</article-title>, <comment>Master&#x2019;s thesis</comment>. <publisher-loc>Blacksburg, Virginia</publisher-loc>: <publisher-name>Virginia Polytechnic Institute and State University</publisher-name>. </citation>
</ref>
<ref id="B22">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Vytenis</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Magnetosphere: From plasma observations to reconnection theory</article-title>. <source>J. Geophys. Res. Space Phys.</source> <volume>125</volume> (<issue>9</issue>), <fpage>JA027865</fpage>. <pub-id pub-id-type="doi">10.1029/2020JA027865</pub-id> </citation>
</ref>
<ref id="B23">
<citation citation-type="confproc">
<person-group person-group-type="author">
<name>
<surname>Wang</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Qiang</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Feng</surname>
<given-names>G.</given-names>
</name>
</person-group> (<year>2007</year>). &#x201c;<article-title>Highly-loaded low-reaction boundary layer suction axial flow compressor</article-title>,&#x201d; in <conf-name>Proceeding ASME Turbo Expo 2007: Power for Land, Sea, and Air</conf-name>, <conf-loc>Montreal, Canada</conf-loc>, <conf-date>March 10, 2009</conf-date> (<publisher-name>ASME</publisher-name>), <fpage>405</fpage>&#x2013;<lpage>412</lpage>. <pub-id pub-id-type="doi">10.1115/GT2007-28191</pub-id> </citation>
</ref>
<ref id="B24">
<citation citation-type="confproc">
<person-group person-group-type="author">
<name>
<surname>Zhang</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Du</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>X.</given-names>
</name>
</person-group> (<year>2016</year>). &#x201c;<article-title>3D unsteady simulation of a low speed low-reaction aspirated compressor</article-title>,&#x201d; in <conf-name>Proceeding ASME Turbo Expo 2016: Turbomachinery Technical Conference and Exposition</conf-name>, <conf-loc>Seoul South Korea</conf-loc>, <conf-date>September 20, 2016</conf-date> (<publisher-name>American Society of Mechanical Engineers.</publisher-name>). <pub-id pub-id-type="doi">10.1115/GT2016-56888</pub-id> </citation>
</ref>
<ref id="B25">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zheng</surname>
<given-names>J. G.</given-names>
</name>
<name>
<surname>Zhao</surname>
<given-names>Z. J.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Cui</surname>
<given-names>Y. D.</given-names>
</name>
<name>
<surname>Khoo</surname>
<given-names>B. C.</given-names>
</name>
</person-group> (<year>2014</year>). <article-title>Numerical simulation of nanosecond pulsed dielectric barrier discharge actuator in a quiescent flow</article-title>. <source>Phys. Fluids</source> <volume>26</volume> (<issue>3</issue>), <fpage>036102</fpage>. <pub-id pub-id-type="doi">10.1063/1.4867708</pub-id> </citation>
</ref>
</ref-list>
<sec id="s9">
<title>Nomenclature</title>
<def-list>
<def-item>
<term id="G1-fenrg.2022.989883">
<inline-formula id="inf46">
<mml:math id="m51">
<mml:mrow>
<mml:mi mathvariant="bold">A</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Correlation matrix</p>
</def>
</def-item>
<def-item>
<term id="G2-fenrg.2022.989883">
<inline-formula id="inf47">
<mml:math id="m52">
<mml:mrow>
<mml:mi>C</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Chord length</p>
</def>
</def-item>
<def-item>
<term id="G3-fenrg.2022.989883">
<inline-formula id="inf48">
<mml:math id="m53">
<mml:mrow>
<mml:msub>
<mml:mi>C</mml:mi>
<mml:mi>p</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Pressure coefficient</p>
</def>
</def-item>
<def-item>
<term id="G4-fenrg.2022.989883">
<inline-formula id="inf49">
<mml:math id="m54">
<mml:mrow>
<mml:msub>
<mml:mi>E</mml:mi>
<mml:mi>p</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Projection errors</p>
</def>
</def-item>
<def-item>
<term id="G5-fenrg.2022.989883">
<inline-formula id="inf50">
<mml:math id="m55">
<mml:mrow>
<mml:mi>f</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Frequency of oscillation</p>
</def>
</def-item>
<def-item>
<term id="G6-fenrg.2022.989883">
<inline-formula id="inf51">
<mml:math id="m56">
<mml:mrow>
<mml:mi>H</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Characteristic length of the separation zone</p>
</def>
</def-item>
<def-item>
<term id="G7-fenrg.2022.989883">
<inline-formula id="inf52">
<mml:math id="m57">
<mml:mrow>
<mml:mi>i</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Incidence</p>
</def>
</def-item>
<def-item>
<term id="G8-fenrg.2022.989883">
<inline-formula id="inf53">
<mml:math id="m58">
<mml:mrow>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Total number of POD modes</p>
</def>
<def>
<p>Total number of POD modes</p>
</def>
</def-item>
<def-item>
<term id="G9-fenrg.2022.989883">
<inline-formula id="inf54">
<mml:math id="m59">
<mml:mrow>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>s</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Total number of snapshots</p>
</def>
<def>
<p>Total number of snapshots</p>
</def>
</def-item>
<def-item>
<term id="G10-fenrg.2022.989883">
<inline-formula id="inf55">
<mml:math id="m60">
<mml:mrow>
<mml:msub>
<mml:mi>&#x3b1;</mml:mi>
<mml:mi>k</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Temporal coefficient of the <italic>k</italic>th mode</p>
</def>
<def>
<p>Temporal coefficient of the <italic>k</italic>th mode</p>
</def>
</def-item>
<def-item>
<term id="G11-fenrg.2022.989883">
<inline-formula id="inf56">
<mml:math id="m61">
<mml:mrow>
<mml:mi mathvariant="normal">M</mml:mi>
<mml:mi mathvariant="normal">a</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Mach number</p>
</def>
</def-item>
<def-item>
<term id="G12-fenrg.2022.989883">
<inline-formula id="inf57">
<mml:math id="m62">
<mml:mrow>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Total number of POD modes</p>
</def>
<def>
<p>Total number of POD modes</p>
</def>
</def-item>
<def-item>
<term id="G13-fenrg.2022.989883">
<inline-formula id="inf58">
<mml:math id="m63">
<mml:mrow>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>s</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Total number of snapshots</p>
</def>
<def>
<p>Total number of snapshots</p>
</def>
</def-item>
<def-item>
<term id="G14-fenrg.2022.989883">
<inline-formula id="inf59">
<mml:math id="m64">
<mml:mrow>
<mml:mi>p</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Static pressure</p>
</def>
</def-item>
<def-item>
<term id="G15-fenrg.2022.989883">
<inline-formula id="inf60">
<mml:math id="m65">
<mml:mrow>
<mml:msub>
<mml:mi>p</mml:mi>
<mml:mn mathvariant="italic">1</mml:mn>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Mass-averaged static pressure at the inlet</p>
</def>
</def-item>
<def-item>
<term id="G16-fenrg.2022.989883">
<inline-formula id="inf61">
<mml:math id="m66">
<mml:mrow>
<mml:msubsup>
<mml:mi>p</mml:mi>
<mml:mn mathvariant="italic">1</mml:mn>
<mml:mo>&#x2a;</mml:mo>
</mml:msubsup>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Mass-averaged total pressure at the inlet</p>
</def>
</def-item>
<def-item>
<term id="G17-fenrg.2022.989883">
<inline-formula id="inf62">
<mml:math id="m67">
<mml:mrow>
<mml:msubsup>
<mml:mi>p</mml:mi>
<mml:mn mathvariant="italic">2</mml:mn>
<mml:mo>&#x2a;</mml:mo>
</mml:msubsup>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Mass-averaged total pressure at the outlet</p>
</def>
</def-item>
<def-item>
<term id="G18-fenrg.2022.989883">
<inline-formula id="inf63">
<mml:math id="m68">
<mml:mrow>
<mml:mi>Pr</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Pressure ratio</p>
</def>
</def-item>
<def-item>
<term id="G19-fenrg.2022.989883">
<inline-formula id="inf64">
<mml:math id="m69">
<mml:mrow>
<mml:mi>Q</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Q-criterion</p>
</def>
</def-item>
<def-item>
<term id="G20-fenrg.2022.989883">
<inline-formula id="inf65">
<mml:math id="m70">
<mml:mrow>
<mml:mi mathvariant="normal">R</mml:mi>
<mml:mi mathvariant="normal">e</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Reynolds number</p>
</def>
</def-item>
<def-item>
<term id="G21-fenrg.2022.989883">
<inline-formula id="inf66">
<mml:math id="m71">
<mml:mrow>
<mml:mi>S</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Strain tensor</p>
</def>
</def-item>
<def-item>
<term id="G22-fenrg.2022.989883">
<inline-formula id="inf67">
<mml:math id="m72">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Strouhal number</p>
</def>
</def-item>
<def-item>
<term id="G23-fenrg.2022.989883">
<inline-formula id="inf68">
<mml:math id="m73">
<mml:mrow>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Time</p>
</def>
</def-item>
<def-item>
<term id="G24-fenrg.2022.989883">
<inline-formula id="inf69">
<mml:math id="m74">
<mml:mrow>
<mml:mi>U</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Streamwies velocity</p>
</def>
</def-item>
<def-item>
<term id="G25-fenrg.2022.989883">
<inline-formula id="inf70">
<mml:math id="m75">
<mml:mrow>
<mml:msub>
<mml:mi>U</mml:mi>
<mml:mrow>
<mml:mi>o</mml:mi>
<mml:mi>u</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Time-averaged velocity at the outlet</p>
</def>
</def-item>
<def-item>
<term id="G26-fenrg.2022.989883">
<inline-formula id="inf71">
<mml:math id="m76">
<mml:mrow>
<mml:msub>
<mml:mi>U</mml:mi>
<mml:mi>s</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Time-averaged velocity at suction slot exit</p>
</def>
</def-item>
<def-item>
<term id="G27-fenrg.2022.989883">
<inline-formula id="inf72">
<mml:math id="m77">
<mml:mrow>
<mml:msub>
<mml:mi>U</mml:mi>
<mml:mn mathvariant="italic">0</mml:mn>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Oscillation amplitude</p>
</def>
</def-item>
<def-item>
<term id="G28-fenrg.2022.989883">
<inline-formula id="inf73">
<mml:math id="m78">
<mml:mrow>
<mml:mi mathvariant="bold">u</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Velocity</p>
</def>
</def-item>
<def-item>
<term id="G29-fenrg.2022.989883">
<inline-formula id="inf74">
<mml:math id="m79">
<mml:mrow>
<mml:msup>
<mml:mi mathvariant="bold">u</mml:mi>
<mml:mo>&#x2032;</mml:mo>
</mml:msup>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Fluctuating velocity</p>
</def>
</def-item>
<def-item>
<term id="G30-fenrg.2022.989883">
<inline-formula id="inf75">
<mml:math id="m80">
<mml:mrow>
<mml:mover accent="true">
<mml:mi mathvariant="bold">u</mml:mi>
<mml:mo>&#xaf;</mml:mo>
</mml:mover>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Time-averaged velocity</p>
</def>
</def-item>
<def-item>
<term id="G31-fenrg.2022.989883">
<inline-formula id="inf76">
<mml:math id="m81">
<mml:mrow>
<mml:msub>
<mml:mi>&#x3b1;</mml:mi>
<mml:mi>k</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Temporal coefficient of the <italic>k</italic>th mode</p>
</def>
<def>
<p>Temporal coefficient of the <italic>k</italic>th mode</p>
</def>
</def-item>
<def-item>
<term id="G32-fenrg.2022.989883">
<inline-formula id="inf77">
<mml:math id="m82">
<mml:mrow>
<mml:mi>&#x3c6;</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Phase of the excitation</p>
</def>
</def-item>
<def-item>
<term id="G33-fenrg.2022.989883">
<inline-formula id="inf78">
<mml:math id="m83">
<mml:mrow>
<mml:msub>
<mml:mi>&#x3bb;</mml:mi>
<mml:mi>k</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>
<italic>k</italic>th eigenvalue</p>
</def>
</def-item>
<def-item>
<term id="G34-fenrg.2022.989883">
<inline-formula id="inf79">
<mml:math id="m84">
<mml:mrow>
<mml:mi>&#x3c9;</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>
</term>
<def>
<p>Total pressure loss coefficient</p>
</def>
</def-item>
</def-list>
<sec>
<title>Abbreviations</title>
<def-list>
<def-item>
<term id="G35-fenrg.2022.989883">AOA</term>
<def>
<p>Angle of attack</p>
</def>
</def-item>
<def-item>
<term id="G36-fenrg.2022.989883">AVDR</term>
<def>
<p>Axial velocity density ratio</p>
</def>
</def-item>
<def-item>
<term id="G37-fenrg.2022.989883">BLS</term>
<def>
<p>Boundary layer suction</p>
</def>
</def-item>
<def-item>
<term id="G38-fenrg.2022.989883">BLOS</term>
<def>
<p>Boundary layer oscillation suction</p>
</def>
</def-item>
<def-item>
<term id="G39-fenrg.2022.989883">CFD</term>
<def>
<p>Computational flow dynamics</p>
</def>
</def-item>
<def-item>
<term id="G40-fenrg.2022.989883">SST</term>
<def>
<p>Shear stress transport</p>
</def>
</def-item>
<def-item>
<term id="G41-fenrg.2022.989883">DES</term>
<def>
<p>Detached eddy simulation</p>
</def>
</def-item>
<def-item>
<term id="G42-fenrg.2022.989883">LES</term>
<def>
<p>Large eddy simulation</p>
</def>
</def-item>
<def-item>
<term id="G43-fenrg.2022.989883">TE</term>
<def>
<p>Trailing edge</p>
</def>
</def-item>
</def-list>
</sec>
</sec>
</back>
</article>