<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="research-article" dtd-version="2.3" xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Energy Res.</journal-id>
<journal-title>Frontiers in Energy Research</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Energy Res.</abbrev-journal-title>
<issn pub-type="epub">2296-598X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">892579</article-id>
<article-id pub-id-type="doi">10.3389/fenrg.2022.892579</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Energy Research</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Comprehensive Evaluation Index System of Distribution Network for Distributed Photovoltaic Access</article-title>
<alt-title alt-title-type="left-running-head">Xiao et al.</alt-title>
<alt-title alt-title-type="right-running-head">Evaluation of Photovoltaic Network Planning</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Xiao</surname>
<given-names>Jinxing</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1712982/overview"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Ye</surname>
<given-names>Ying</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Wang</surname>
<given-names>Fa</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Shen</surname>
<given-names>Jieshi</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Gao</surname>
<given-names>Feng</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
</contrib>
</contrib-group>
<aff id="aff1">
<sup>1</sup>
<institution>State Grid Shanghai Municipal Electric Power Company</institution>, <addr-line>Shanghai</addr-line>, <country>China</country>
</aff>
<aff id="aff2">
<sup>2</sup>
<institution>State Grid Shanghai Jinshan Electric Power Supply Company</institution>, <addr-line>Shanghai</addr-line>, <country>China</country>
</aff>
<author-notes>
<fn fn-type="edited-by">
<p>
<bold>Edited by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/808496/overview">Haris M. Khalid</ext-link>, Higher Colleges of Technology, United Arab Emirates</p>
</fn>
<fn fn-type="edited-by">
<p>
<bold>Reviewed by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1020193/overview">Yanbo Chen</ext-link>, North China Electric Power University, China</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/507713/overview">Minh Quan Duong</ext-link>, The University of Danang, Vietnam</p>
</fn>
<corresp id="c001">&#x2a;Correspondence: Jinxing Xiao, <email>xiaojinxing2233@163.com</email>
</corresp>
<fn fn-type="other">
<p>This article was submitted to Smart Grids, a section of the journal Frontiers in Energy Research</p>
</fn>
</author-notes>
<pub-date pub-type="epub">
<day>12</day>
<month>08</month>
<year>2022</year>
</pub-date>
<pub-date pub-type="collection">
<year>2022</year>
</pub-date>
<volume>10</volume>
<elocation-id>892579</elocation-id>
<history>
<date date-type="received">
<day>10</day>
<month>03</month>
<year>2022</year>
</date>
<date date-type="accepted">
<day>13</day>
<month>06</month>
<year>2022</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2022 Xiao, Ye, Wang, Shen and Gao.</copyright-statement>
<copyright-year>2022</copyright-year>
<copyright-holder>Xiao, Ye, Wang, Shen and Gao</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<p>Affected by the light intensity and multiple adjacent stations, the output power of photovoltaic power stations presents the characteristics of randomness and correlation, which puts forward new requirements for the safe operation and planning evaluation of the distribution network. First, in order to accurately describe the randomness and fluctuation of photovoltaic output, a Gaussian mixture model based on an improved optimal particle swarm optimization algorithm is proposed, and the joint probability density function of multiple photovoltaic outputs is solved. Then, the power flow equation is linearized, the linear expressions of bus voltage and line power flow are derived, and the joint probability distributions of multi-node voltage and multi-line power flow are obtained, respectively. Based on this, the reliability index and voltage quality index in the presence of the distributed renewable energy were constructed. Finally, the novel power grid planning evaluation index is tested in a real system in China, the combined weight is determined by the analytic hierarchy process, and the comprehensive evaluation results are obtained. The simulation results prove the feasibility of the evaluation index system.</p>
</abstract>
<kwd-group>
<kwd>particle swarm algorithm</kwd>
<kwd>Gaussian mixture model</kwd>
<kwd>voltage distribution index</kwd>
<kwd>analytic hierarchy process</kwd>
<kwd>comprehensive evaluation index system</kwd>
</kwd-group>
</article-meta>
</front>
<body>
<sec id="s1">
<title>1 Introduction</title>
<sec id="s1-1">
<title>1.1 Motivation</title>
<p>In recent years, China has provided policy support for the development and utilization of clean energy, which has promoted the development of renewable energy power generation (<xref ref-type="bibr" rid="B27">Zhang et al., 2022a</xref>; <xref ref-type="bibr" rid="B29">Zhang et al., 2022b</xref>; <xref ref-type="bibr" rid="B17">Song et al., 2022</xref>). The access to distributed photovoltaic energy in the distribution network brings the operation of the power system more uncertainty and puts forward higher requirements for distribution network planning (<xref ref-type="bibr" rid="B30">Zhang et al., 2019a</xref>). In order to optimize the operation of the distribution network, (<xref ref-type="bibr" rid="B23">Xiao et al. 2021</xref>) proposed a comprehensive control method for negative sequence current suppression and reactive power compensation. The optimal placement and sizing of distribution static compensator in radial distribution networks as multi-objective optimization with the objective of power loss reduction using whale optimization algorithm is discussed by (<xref ref-type="bibr" rid="B13">Noori et al. 2021</xref>). However, the compensation effects are rarely considered when evaluating distribution network planning options. In addition, the distribution network planning evaluation system based on a deterministic model and deterministic power flow will be difficult to be effectively applied to an active power distribution network (<xref ref-type="bibr" rid="B11">Meera and Hemamalini, 2021</xref>).</p>
</sec>
<sec id="s1-2">
<title>1.2 Literature Survey</title>
<p>At present, a relatively standardized comprehensive evaluation system for distribution network planning (<xref ref-type="bibr" rid="B18">Song and Zhu, 2021</xref>; <xref ref-type="bibr" rid="B3">Dong et al., 2022</xref>) has been formed, covering flexibility, coordination, economy, and power supply reliability. In order to consider the characteristics of renewable energy, (<xref ref-type="bibr" rid="B26">Zeng et al. 2016</xref>) considered the environmental protection effects brought by a large number of distributed generators connected to the distribution network, and the index evaluation system of the new energy distribution network considering environmental protection and the comprehensive evaluation model of environmental benefits of intelligent distribution network were established, respectively. Based on the big data analysis method, (<xref ref-type="bibr" rid="B19">Visser et al. 2022</xref>) realized the comprehensive evaluation of the distribution network including &#x201c;performance&#x201d; and &#x201c;benefit.&#x201d; On this basis, (<xref ref-type="bibr" rid="B9">Li et al. 2018</xref>) constructed a four-tier index system including user energy efficiency and environmental pollution.</p>
<p>However, the existing research has not considered the volatility and intermittence brought by photovoltaic access to the power grid. Different from the traditional distribution network, for the fluctuation of the output power of distributed photovoltaic power stations and the correlation of the output of multiple photovoltaic electric fields (<xref ref-type="bibr" rid="B12">Murata et al., 2009</xref>), it is necessary to consider the power flow limit and voltage limit of the system caused by the aforementioned characteristics in the evaluation of distribution network (<xref ref-type="bibr" rid="B4">Ferm&#xed;n et al., 2022</xref>).</p>
<p>At present, the description of the fluctuation of photovoltaic output is usually based on the probability density function method (<xref ref-type="bibr" rid="B10">Liu et al., 2016</xref>; <xref ref-type="bibr" rid="B31">Zhang et al., 2019b</xref>; <xref ref-type="bibr" rid="B2">Chen et al., 2020</xref>). (<xref ref-type="bibr" rid="B24">Yang et al. 2017</xref>) and (<xref ref-type="bibr" rid="B22">Xiang et al. 2019</xref>) show the robust optimization model that effectively reflects the probability distribution characteristics of new energy. (<xref ref-type="bibr" rid="B20">Wang et al. 2022</xref>) proposed a spectrum analysis method based on an autoregressive model to analyze the fluctuation characteristics of photovoltaic output. (<xref ref-type="bibr" rid="B25">Yu et al. 2019</xref>) showed that the random characteristics of the actual output of photovoltaic power station approximately obey the beta distribution. (<xref ref-type="bibr" rid="B21">Wu et al. 2015</xref>) used the exponential distribution to simulate the variation characteristics of photovoltaic power and evaluate the short-term power fluctuation amplitude.</p>
<p>In general, the Pearson correlation coefficient method (<xref ref-type="bibr" rid="B6">Jia et al., 2021</xref>) and the copular function fitting method (<xref ref-type="bibr" rid="B15">Rajabalizadeh and Tafreshi, 2020</xref>) are extensively used to describe the output correlation of photovoltaic power stations. The Pearson correlation coefficient method can only characterize simple linear correlation (<xref ref-type="bibr" rid="B16">Singh et al., 2010</xref>). Compared with that, copular function has higher flexibility, but it is more complex to find the optimal parameters of copular function with actual data (<xref ref-type="bibr" rid="B8">Jin et al., 2021</xref>).</p>
<p>Existing methods can be categorized into two groups: 1) the refinement modeling of random characteristics for the output power of photovoltaic power station; 2) the refinement modeling of correlation characteristics for the output power of photovoltaic power station. However, it is hard to simultaneously depict them. Gaussian mixture model can effectively simulate the random characteristics of photovoltaic output and can describe the correlation of output power of multiple photovoltaic power stations based on their joint distribution (<xref ref-type="bibr" rid="B7">Jiang et al., 2015</xref>). In addition, the voltage and power flow limits will endanger the safe operation of the power grid. Therefore, when establishing the distribution network planning evaluation system of distributed photovoltaic access, it is necessary to consider the over-limit risk of voltage and power flow at the same time.</p>
</sec>
<sec id="s1-3">
<title>1.3 Contributions</title>
<p>To address these important issues, this study proposes a comprehensive evaluation index system for distribution networks for distributed photovoltaic access. Relative to the state-of-the-art, the contributions of this study are threefold:<list list-type="simple">
<list-item>
<p>1) In the modeling of the randomness and correlation of output power of multiple photovoltaic power stations, the GMM based on the improved particle swarm optimization algorithm is proposed.</p>
</list-item>
<list-item>
<p>2) For the solution methodology, the joint probability density function and joint distribution function of multi-node voltage and multi-line power flow are solved based on the linearized power flow equation. By doing so, the novel distribution network evaluation indexes such as voltage out-of-limit index are defined based on the probability density function.</p>
</list-item>
<list-item>
<p>3) After the three novel indexes, such as voltage out-of-limit risk indicators, voltage deviation indicators, and power flow cross-section out-of-limit risk indicators are incorporated into the distribution network planning evaluation system, the comprehensive evaluation index system of the distribution network for distributed photovoltaic access has been formed.</p>
</list-item>
</list>
</p>
</sec>
<sec id="s1-4">
<title>1.4 Organization</title>
<p>The first section of the article is the introduction. <xref ref-type="sec" rid="s2">Section 2</xref> provides the uncertainty model considering the randomness and correlation of photovoltaic power stations; <xref ref-type="sec" rid="s3">Section 3</xref> discusses the analytical probabilistic power flow analysis method based on a linearized power flow equation. In <xref ref-type="sec" rid="s4">Section 4</xref>, the evaluation system of distribution network planning considering power flow uncertainty are shown. Simulation analysis is presented in <xref ref-type="sec" rid="s5">Section 5</xref>. The conclusion and limitations are provided at the end of this article.</p>
</sec>
</sec>
<sec id="s2">
<title>2 The Uncertainty Model Considering the Randomness and Correlation of Output of Photovoltaic Power Station</title>
<p>Distributed photovoltaic access to the distribution network makes the node voltage and line power flow fluctuate. The traditional deterministic model is hard to describe the fluctuation characteristics of renewable energy in detail. Therefore, considering the randomness and correlation of photovoltaic power station output, this section first establishes an uncertainty model for distributed photovoltaic access.</p>
<sec id="s2-1">
<title>2.1 Gaussian Mixture Model</title>
<p>Gaussian mixture model (GMM) can accurately model non-Gaussian random variables and can approximate any probability density distribution with the help of a linear combination of a certain amount of Gaussian density function (<xref ref-type="bibr" rid="B1">Angelim and Affonso, 2020</xref>), shown as follows:<disp-formula id="e1">
<mml:math id="m1">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="italic">f</mml:mi>
<mml:mrow>
<mml:mover accent="true">
<mml:mi mathvariant="bold-italic">X</mml:mi>
<mml:mo>&#x2dc;</mml:mo>
</mml:mover>
</mml:mrow>
</mml:msub>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mi mathvariant="bold-italic">X</mml:mi>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mo>&#x3d;</mml:mo>
<mml:mstyle displaystyle="true">
<mml:munderover>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi mathvariant="italic">m</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi mathvariant="italic">M</mml:mi>
</mml:munderover>
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="italic">&#x3c9;</mml:mi>
<mml:mi mathvariant="italic">m</mml:mi>
</mml:msub>
<mml:msub>
<mml:mi mathvariant="italic">N</mml:mi>
<mml:mi mathvariant="italic">m</mml:mi>
</mml:msub>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mrow>
<mml:mi mathvariant="bold-italic">X</mml:mi>
<mml:mo>&#x7c;</mml:mo>
</mml:mrow>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3bc;</mml:mi>
<mml:mi mathvariant="italic">m</mml:mi>
</mml:msub>
<mml:mo>,</mml:mo>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3a3;</mml:mi>
<mml:mi mathvariant="italic">m</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:mstyle>
<mml:mo>,</mml:mo>
<mml:mstyle displaystyle="true">
<mml:munderover>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi mathvariant="italic">m&#x3d;1</mml:mi>
</mml:mrow>
<mml:mi mathvariant="italic">M</mml:mi>
</mml:munderover>
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="italic">&#x3c9;</mml:mi>
<mml:mi mathvariant="italic">m</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mstyle>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
<mml:mo>,</mml:mo>
</mml:mrow>
</mml:math>
<label>(1)</label>
</disp-formula>
<disp-formula id="e2">
<mml:math id="m2">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="italic">N</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mrow>
<mml:mi mathvariant="bold-italic">X</mml:mi>
<mml:mo>&#x7c;</mml:mo>
</mml:mrow>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3bc;</mml:mi>
<mml:mi mathvariant="italic">m</mml:mi>
</mml:msub>
<mml:mo>,</mml:mo>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3a3;</mml:mi>
<mml:mi mathvariant="italic">m</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mi mathvariant="bold">exp</mml:mi>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mo>&#x2212;</mml:mo>
<mml:mfrac>
<mml:mn>1</mml:mn>
<mml:mn>2</mml:mn>
</mml:mfrac>
<mml:msup>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mi mathvariant="bold-italic">X</mml:mi>
<mml:mo>&#x2212;</mml:mo>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3a3;</mml:mi>
<mml:mi mathvariant="italic">m</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mi mathvariant="normal">T</mml:mi>
</mml:msup>
<mml:msubsup>
<mml:mi mathvariant="bold-italic">&#x3a3;</mml:mi>
<mml:mi>i</mml:mi>
<mml:mrow>
<mml:mo>&#x2212;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
</mml:msubsup>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mi mathvariant="bold-italic">X</mml:mi>
<mml:mo>&#x2212;</mml:mo>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3bc;</mml:mi>
<mml:mi mathvariant="italic">m</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mn>2</mml:mn>
<mml:mi mathvariant="bold">&#x3c0;</mml:mi>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mrow>
<mml:mrow>
<mml:mi>W</mml:mi>
<mml:mo>/</mml:mo>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:mrow>
</mml:msup>
<mml:mi>det</mml:mi>
<mml:msup>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3a3;</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mrow>
<mml:mrow>
<mml:mi>W</mml:mi>
<mml:mo>/</mml:mo>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:mrow>
</mml:msup>
</mml:mrow>
</mml:mfrac>
<mml:mo>,</mml:mo>
</mml:mrow>
</mml:math>
<label>(2)</label>
</disp-formula>where <bold>
<italic>X</italic>
</bold> is the input variable of the expression and represents the output power vector of the photovoltaic power station; <inline-formula id="inf1">
<mml:math id="m3">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="italic">&#x3c9;</mml:mi>
<mml:mi mathvariant="italic">m</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> represents the weight coefficient of the <italic>m</italic>th Gaussian distribution sub-component; <inline-formula id="inf2">
<mml:math id="m4">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3bc;</mml:mi>
<mml:mi mathvariant="italic">m</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> and <inline-formula id="inf3">
<mml:math id="m5">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3a3;</mml:mi>
<mml:mi mathvariant="italic">m</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> represent the expectation vector and covariance matrix of the <italic>m</italic>th Gaussian sub-component, respectively, in which the non-diagonal elements of the covariance matrix are used to describe the correlation between different photovoltaic power stations. The parameters of GMM that needs to be further estimated are <inline-formula id="inf4">
<mml:math id="m6">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="italic">&#x3c9;</mml:mi>
<mml:mi mathvariant="italic">m</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> , <inline-formula id="inf5">
<mml:math id="m7">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3bc;</mml:mi>
<mml:mi mathvariant="italic">m</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>, and <inline-formula id="inf6">
<mml:math id="m8">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3a3;</mml:mi>
<mml:mi mathvariant="italic">m</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>.</p>
<p>In parameter estimation, the samples <inline-formula id="inf7">
<mml:math id="m9">
<mml:mrow>
<mml:mi mathvariant="italic">X</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mrow>
<mml:mo>{</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="italic">X</mml:mi>
<mml:mn>1</mml:mn>
</mml:msub>
<mml:mi mathvariant="normal">,</mml:mi>
<mml:mo>&#x22ef;</mml:mo>
<mml:mi mathvariant="normal">,</mml:mi>
<mml:msub>
<mml:mi mathvariant="italic">X</mml:mi>
<mml:mi mathvariant="italic">N</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>}</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula> based on the actual collected output active power of the photovoltaic power station are formed first, and the likelihood function is built then, as shown in <xref ref-type="disp-formula" rid="e3">Eqs. 3</xref>, <xref ref-type="disp-formula" rid="e4">4</xref>.the following equations:<disp-formula id="e3">
<mml:math id="m10">
<mml:mrow>
<mml:mi mathvariant="italic">L</mml:mi>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="italic">X</mml:mi>
<mml:mn>1</mml:mn>
</mml:msub>
<mml:mo>,</mml:mo>
<mml:mo>&#x22ef;</mml:mo>
<mml:msub>
<mml:mi mathvariant="italic">X</mml:mi>
<mml:mi mathvariant="italic">N</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mo>&#x3d;</mml:mo>
<mml:mstyle displaystyle="true">
<mml:munderover>
<mml:mo>&#x220f;</mml:mo>
<mml:mrow>
<mml:mi mathvariant="italic">j</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi mathvariant="italic">N</mml:mi>
</mml:munderover>
<mml:mrow>
<mml:mi mathvariant="italic">f</mml:mi>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="italic">X</mml:mi>
<mml:mi mathvariant="italic">j</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:mstyle>
<mml:mo>,</mml:mo>
</mml:mrow>
</mml:math>
<label>(3)</label>
</disp-formula>
<disp-formula id="e4">
<mml:math id="m11">
<mml:mrow>
<mml:mi>ln</mml:mi>
<mml:mi mathvariant="italic">L</mml:mi>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="italic">X</mml:mi>
<mml:mn>1</mml:mn>
</mml:msub>
<mml:mo>,</mml:mo>
<mml:mo>&#x22ef;</mml:mo>
<mml:msub>
<mml:mi mathvariant="italic">X</mml:mi>
<mml:mi mathvariant="italic">N</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mo>&#x3d;</mml:mo>
<mml:mstyle displaystyle="true">
<mml:munderover>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi mathvariant="italic">j</mml:mi>
<mml:mi mathvariant="normal">&#x3d;1</mml:mi>
</mml:mrow>
<mml:mi mathvariant="italic">N</mml:mi>
</mml:munderover>
<mml:mrow>
<mml:mi>ln</mml:mi>
<mml:mstyle displaystyle="true">
<mml:munderover>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi mathvariant="italic">m</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi mathvariant="italic">M</mml:mi>
</mml:munderover>
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="italic">&#x3c9;</mml:mi>
<mml:mi mathvariant="italic">m</mml:mi>
</mml:msub>
<mml:msub>
<mml:mi mathvariant="italic">N</mml:mi>
<mml:mi mathvariant="italic">m</mml:mi>
</mml:msub>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="italic">X</mml:mi>
<mml:mi mathvariant="italic">j</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:mstyle>
</mml:mrow>
</mml:mstyle>
<mml:mo>.</mml:mo>
</mml:mrow>
</mml:math>
<label>(4)</label>
</disp-formula>
</p>
<p>Then, iterative optimization is carried out with the maximum likelihood function as the optimization objective, and the optimization result parameters are the parameters that GMM needs to be estimated.</p>
</sec>
<sec id="s2-2">
<title>2.2 Parameter Solution of the Gaussian Mixture Model Based on Improved Particle Swarm Optimization Algorithm</title>
<p>In the traditional GMM parameter solving process, the expectation maximization (EM) algorithm is extensively used. Considering that the accuracy of the algorithm depends on the selection of the initial value, the improper initial value may lead to the local optimal solution during the iterative optimization, which will have a negative impact on the next settlement results. In contrast, the improved optimal particle swarm optimization algorithm can greatly reduce the influence of initial value and realize the balance of global optimization and local optimization ability, so it is easier to obtain the global optimal solution (<xref ref-type="bibr" rid="B14">Peng et al., 2017</xref>). Therefore, this section adopts the improved particle swarm optimization algorithm.<list list-type="simple">
<list-item>
<p>1) First, the particle swarm <inline-formula id="inf8">
<mml:math id="m12">
<mml:mrow>
<mml:mi>x</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mrow>
<mml:mo>[</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi>&#x3c9;</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
<mml:mo>,</mml:mo>
<mml:msub>
<mml:mi>&#x3bc;</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
<mml:mo>,</mml:mo>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3a3;</mml:mi>
<mml:mi mathvariant="italic">m</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>]</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula> to be determined is formed to initialize the particle position and velocity.</p>
</list-item>
<list-item>
<p>2) Then, the position and velocity of particles are updated in each iteration, as shown in <xref ref-type="disp-formula" rid="e5">Eqs. 5</xref>, <xref ref-type="disp-formula" rid="e6">6</xref>.the following equations:</p>
</list-item>
</list>
<disp-formula id="e5">
<mml:math id="m13">
<mml:mtable columnalign="left">
<mml:mtr>
<mml:mtd>
<mml:msub>
<mml:mi>v</mml:mi>
<mml:mi>i</mml:mi>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mi>&#x3bb;</mml:mi>
<mml:msub>
<mml:mi>v</mml:mi>
<mml:mi>i</mml:mi>
</mml:msub>
<mml:mo>&#x2b;</mml:mo>
<mml:msub>
<mml:mi>c</mml:mi>
<mml:mn>1</mml:mn>
</mml:msub>
<mml:mi>r</mml:mi>
<mml:mi>a</mml:mi>
<mml:mi>n</mml:mi>
<mml:mi>d</mml:mi>
<mml:mi>o</mml:mi>
<mml:mi>m</mml:mi>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mn>0,1</mml:mn>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi>p</mml:mi>
<mml:mi>i</mml:mi>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:msub>
<mml:mi>x</mml:mi>
<mml:mi>i</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mtd>
</mml:mtr>
<mml:mtr>
<mml:mtd>
<mml:mo>&#x2b;</mml:mo>
<mml:msub>
<mml:mi>c</mml:mi>
<mml:mn>2</mml:mn>
</mml:msub>
<mml:mi>r</mml:mi>
<mml:mi>a</mml:mi>
<mml:mi>n</mml:mi>
<mml:mi>d</mml:mi>
<mml:mi>o</mml:mi>
<mml:mi>m</mml:mi>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mn>0,1</mml:mn>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi>g</mml:mi>
<mml:mi>i</mml:mi>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:msub>
<mml:mi>x</mml:mi>
<mml:mi>i</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mo>,</mml:mo>
</mml:mtd>
</mml:mtr>
</mml:mtable>
</mml:math>
<label>(5)</label>
</disp-formula>
<disp-formula id="e6">
<mml:math id="m14">
<mml:mrow>
<mml:msub>
<mml:mi>x</mml:mi>
<mml:mi>i</mml:mi>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mi>x</mml:mi>
<mml:mi>i</mml:mi>
</mml:msub>
<mml:mo>&#x2b;</mml:mo>
<mml:msub>
<mml:mi>v</mml:mi>
<mml:mi>i</mml:mi>
</mml:msub>
<mml:mo>,</mml:mo>
</mml:mrow>
</mml:math>
<label>(6)</label>
</disp-formula>where <italic>c</italic>
<sub>
<italic>1</italic>
</sub> and <italic>c</italic>
<sub>
<italic>2</italic>
</sub> represent the acceleration constants. Generally taken as <inline-formula id="inf9">
<mml:math id="m15">
<mml:mrow>
<mml:msub>
<mml:mi>c</mml:mi>
<mml:mn>1</mml:mn>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mi>c</mml:mi>
<mml:mn>2</mml:mn>
</mml:msub>
<mml:mo>&#x2208;</mml:mo>
<mml:mrow>
<mml:mo>[</mml:mo>
<mml:mrow>
<mml:mn>0,4</mml:mn>
</mml:mrow>
<mml:mo>]</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula>, <italic>v</italic>
<sub>
<italic>i</italic>
</sub> and <italic>x</italic>
<sub>
<italic>i</italic>
</sub> represent the velocity and current position of the particle, <italic>p</italic>
<sub>
<italic>i</italic>
</sub> and <italic>g</italic>
<sub>
<italic>i</italic>
</sub> correspond to the optimal position and global optimal position searched by the current particle, and random (0,1) represents the random number on the interval [0,1]. As the inertia factor, the research shows that the dynamic value can obtain a better optimization effect than the fixed value. Here, the linear decreasing weight (LDW) strategy can be adopted, that is,<disp-formula id="e7">
<mml:math id="m16">
<mml:mrow>
<mml:mi>&#x3bb;</mml:mi>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mi>k</mml:mi>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mi>&#x3bb;</mml:mi>
<mml:mrow>
<mml:mi>s</mml:mi>
<mml:mi>t</mml:mi>
<mml:mi>a</mml:mi>
<mml:mi>r</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi>&#x3bb;</mml:mi>
<mml:mrow>
<mml:mi>s</mml:mi>
<mml:mi>t</mml:mi>
<mml:mi>a</mml:mi>
<mml:mi>r</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:msub>
<mml:mi>&#x3bb;</mml:mi>
<mml:mrow>
<mml:mi>e</mml:mi>
<mml:mi>n</mml:mi>
<mml:mi>d</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mfrac>
<mml:mrow>
<mml:msub>
<mml:mi>T</mml:mi>
<mml:mrow>
<mml:mi>max</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>k</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:msub>
<mml:mi>T</mml:mi>
<mml:mrow>
<mml:mi>max</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:mfrac>
<mml:mo>,</mml:mo>
</mml:mrow>
</mml:math>
<label>(7)</label>
</disp-formula>where <italic>&#x3bb;</italic>
<sub>
<italic>start</italic>
</sub> and <italic>&#x3bb;</italic>
<sub>
<italic>end</italic>
</sub> represent the initial weight and final weight, respectively, <italic>k</italic> represents the current number of iterations, and <italic>T</italic>
<sub>
<italic>max</italic>
</sub> represents the maximum number of iterations.<list list-type="simple">
<list-item>
<p>3) Calculate the updated particle according to the set objective function <xref ref-type="disp-formula" rid="e4">Formula 4</xref>, update and record the current optimal value and the global optimal value of the particle.</p>
</list-item>
<list-item>
<p>4) Check whether the upper limit of cycle times is reached or whether the difference between algebras meets the error constraints. If so, the calculation ends and the result is output, otherwise, go to step 2 to continue the calculation.</p>
</list-item>
</list>
</p>
</sec>
</sec>
<sec id="s3">
<title>3 Analytical Probabilistic Power Flow Analysis Method Based on the Linearized Power Flow Equation</title>
<p>After Gaussian mixture model modeling, the output power of the photovoltaic power station follows the Gaussian distribution. For the occasions that need to repeat large-scale power flow calculations, such as distribution network reliability assessment and distribution network probabilistic power flow, the use of a linearized power flow model can improve the calculation efficiency, and there is no convergence problem.</p>
<sec id="s3-1">
<title>3.1 Linear Power Flow Model of Distribution Network</title>
<p>The structural configuration of the traditional distribution network is that there is only one generator as the swing bus, and the rest are all PQ nodes, excluding PV nodes. The research on the linearized power flow equation of the distribution network has been relatively mature. However, since the distribution network is connected to the distributed photovoltaic power station, sometimes it needs to be processed as a PV node in the power flow calculation, and the ZIP load is getting more and more attention in the analysis of the distribution network. Thus, it is necessary to establish a more applicable power flow calculation method for the distribution network.</p>
<p>In this section, the DG access node is regarded as a PV node, the load is set as the ZIP model, the node injection power equation is used as the original power flow equation, the power flow equation is linearized, and the linear power flow equation between node voltage amplitude and line power and injection power is derived. The final linearized power flow equation is as follows:<disp-formula id="e8">
<mml:math id="m17">
<mml:mtable columnalign="left">
<mml:mtr>
<mml:mtd>
<mml:mi>V</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mi>A</mml:mi>
<mml:mn>1</mml:mn>
</mml:msub>
<mml:mi>X</mml:mi>
<mml:mo>&#x2b;</mml:mo>
<mml:msub>
<mml:mi>B</mml:mi>
<mml:mn>1</mml:mn>
</mml:msub>
<mml:mo>,</mml:mo>
</mml:mtd>
</mml:mtr>
<mml:mtr>
<mml:mtd>
<mml:mi>S</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mi>A</mml:mi>
<mml:mn>2</mml:mn>
</mml:msub>
<mml:mi>X</mml:mi>
<mml:mo>&#x2b;</mml:mo>
<mml:msub>
<mml:mi>B</mml:mi>
<mml:mn>2</mml:mn>
</mml:msub>
<mml:mo>,</mml:mo>
</mml:mtd>
</mml:mtr>
</mml:mtable>
</mml:math>
<label>(8)</label>
</disp-formula>where <italic>V</italic> and <italic>S</italic> are the output variables and represent the node voltage amplitude and branch power flow, respectively. <italic>X</italic> is the input variable and represents the photovoltaic active output. <italic>A</italic>
<sub>
<italic>1</italic>
</sub>, <italic>A</italic>
<sub>
<italic>2</italic>
</sub>, <italic>B</italic>
<sub>
<italic>1</italic>
</sub>, and <italic>B</italic>
<sub>
<italic>2</italic>
</sub> are linearization expression coefficients. In order to simplify the expression, all linearized expressions are uniformly expressed as shown in <xref ref-type="disp-formula" rid="e9">Eq. 9</xref> the following equation:<disp-formula id="e9">
<mml:math id="m18">
<mml:mrow>
<mml:mi>W</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mi>B</mml:mi>
<mml:mi>X</mml:mi>
<mml:mo>&#x2b;</mml:mo>
<mml:mi>C</mml:mi>
<mml:mo>,</mml:mo>
</mml:mrow>
</mml:math>
<label>(9)</label>
</disp-formula>where <italic>W</italic> is the output variable, representing the node voltage amplitude and branch power; <italic>X</italic> is the input variable and represents the active output of new energy. <italic>B</italic> and <italic>C</italic> are the coefficients of linearization expression.</p>
</sec>
<sec id="s3-2">
<title>3.2 Description Diagram of Node Voltage and Section Power Flow Probability Distribution</title>
<p>If the random variable obeys Gaussian distribution, it still obeys Gaussian distribution after linear transformation. Therefore, the output power <italic>X</italic> of a photovoltaic power station is modeled based on multivariable Gaussian distribution <italic>Nm (x)</italic> first, and after linear transformation in <xref ref-type="disp-formula" rid="e9">Eq. 9</xref>, the node voltage and line power flow also obey Gaussian distribution. Here, the node voltage is selected for derivation. The amplitude of the node voltage follows Gaussian distribution, in which the expectation vector is <italic>A&#x3bc;</italic>
<sub>
<italic>m</italic>
</sub> <italic>&#x2b; B</italic>
<sub>
<italic>1</italic>,</sub> the covariance matrix is <italic>A&#x3a3;</italic>
<sub>
<italic>m</italic>
</sub>
<italic>A</italic>
<sup>
<italic>T</italic>
</sup>, so the joint probability density function (PDF) of node voltage can be expressed as<disp-formula id="e10">
<mml:math id="m19">
<mml:mtable>
<mml:mtr>
<mml:mtd>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mi mathvariant="bold-italic">W&#x7c;</mml:mi>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3bc;</mml:mi>
<mml:mi mathvariant="italic">m</mml:mi>
</mml:msub>
<mml:mi mathvariant="normal">,</mml:mi>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3a3;</mml:mi>
<mml:mi mathvariant="italic">m</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mn>1</mml:mn>
<mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mn>2</mml:mn>
<mml:mi>&#x3c0;</mml:mi>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mrow>
<mml:mi>K</mml:mi>
<mml:mo>/</mml:mo>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:msup>
<mml:mi>det</mml:mi>
<mml:msup>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mi mathvariant="bold-italic">B</mml:mi>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3a3;</mml:mi>
<mml:mi mathvariant="bold-italic">m</mml:mi>
</mml:msub>
<mml:msup>
<mml:mi mathvariant="bold-italic">B</mml:mi>
<mml:mi mathvariant="bold-italic">T</mml:mi>
</mml:msup>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mrow>
<mml:mn>1</mml:mn>
<mml:mo>/</mml:mo>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:msup>
</mml:mrow>
</mml:mfrac>
</mml:mtd>
</mml:mtr>
<mml:mtr>
<mml:mtd>
<mml:mo>&#xd7;</mml:mo>
<mml:msup>
<mml:mi mathvariant="italic">e</mml:mi>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mo>&#x2212;</mml:mo>
<mml:mfrac>
<mml:mn>1</mml:mn>
<mml:mn>2</mml:mn>
</mml:mfrac>
<mml:msup>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mi mathvariant="bold-italic">W</mml:mi>
<mml:mo>-</mml:mo>
<mml:mi mathvariant="bold-italic">B</mml:mi>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3bc;</mml:mi>
<mml:mi mathvariant="bold-italic">m</mml:mi>
</mml:msub>
<mml:mo>-</mml:mo>
<mml:mi mathvariant="bold-italic">C</mml:mi>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mi>T</mml:mi>
</mml:msup>
<mml:mstyle displaystyle="true">
<mml:msubsup>
<mml:mo>&#x2211;</mml:mo>
<mml:mi>i</mml:mi>
<mml:mrow>
<mml:mo>&#x2212;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
</mml:msubsup>
<mml:mrow>
<mml:mi mathvariant="bold-italic">W</mml:mi>
<mml:mi mathvariant="bold-italic">-B</mml:mi>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3bc;</mml:mi>
<mml:mi mathvariant="bold-italic">m</mml:mi>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:mi mathvariant="bold-italic">C</mml:mi>
</mml:mrow>
</mml:mstyle>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:msup>
<mml:mo>,</mml:mo>
</mml:mtd>
</mml:mtr>
</mml:mtable>
</mml:math>
<label>(10)</label>
</disp-formula>where <italic>K</italic> represents the number of nodes. By multiple integrations of <xref ref-type="disp-formula" rid="e10">Eq. 10</xref>, the joint cumulative distribution function (CDF) of node voltage <italic>V</italic> can be obtained, as shown in the following equation: <xref ref-type="disp-formula" rid="e11">Eq. 11</xref>,<disp-formula id="e11">
<mml:math id="m20">
<mml:mrow>
<mml:msub>
<mml:mi>F</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mi mathvariant="bold-italic">W</mml:mi>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mo>&#x3d;</mml:mo>
<mml:mstyle displaystyle="true">
<mml:mrow>
<mml:mo>&#x222b;</mml:mo>
<mml:mrow>
<mml:mo>&#x22ef;</mml:mo>
<mml:mstyle displaystyle="true">
<mml:mrow>
<mml:msubsup>
<mml:mo>&#x222b;</mml:mo>
<mml:mrow>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>&#x221e;</mml:mi>
</mml:mrow>
<mml:mi mathvariant="italic">W</mml:mi>
</mml:msubsup>
<mml:mrow>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mi mathvariant="bold-italic">W</mml:mi>
<mml:mo>&#x7c;</mml:mo>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3bc;</mml:mi>
<mml:mi mathvariant="italic">m</mml:mi>
</mml:msub>
<mml:mo>,</mml:mo>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3a3;</mml:mi>
<mml:mi mathvariant="bold-italic">m</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:mrow>
</mml:mstyle>
</mml:mrow>
</mml:mrow>
</mml:mstyle>
<mml:mi>d</mml:mi>
<mml:msub>
<mml:mi>W</mml:mi>
<mml:mn>1</mml:mn>
</mml:msub>
<mml:mo>&#x22ef;</mml:mo>
<mml:mi>d</mml:mi>
<mml:msub>
<mml:mi>W</mml:mi>
<mml:mi>k</mml:mi>
</mml:msub>
<mml:mo>.</mml:mo>
</mml:mrow>
</mml:math>
<label>(11)</label>
</disp-formula>
</p>
<p>When photovoltaic power X is modeled by GMM with multiple weights and variables, the joint CDF of node voltage can be expressed as<disp-formula id="e12">
<mml:math id="m21">
<mml:mtable>
<mml:mtr>
<mml:mtd>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mi mathvariant="bold-italic">W</mml:mi>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mo>&#x3d;</mml:mo>
<mml:mstyle displaystyle="true">
<mml:mrow>
<mml:mo>&#x222b;</mml:mo>
<mml:mrow>
<mml:mo>&#x22ef;</mml:mo>
<mml:mstyle displaystyle="true">
<mml:mrow>
<mml:msubsup>
<mml:mo>&#x222b;</mml:mo>
<mml:mrow>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>&#x221e;</mml:mi>
</mml:mrow>
<mml:mi>W</mml:mi>
</mml:msubsup>
<mml:mrow>
<mml:mstyle displaystyle="true">
<mml:munderover>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi>m</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>M</mml:mi>
</mml:munderover>
<mml:mrow>
<mml:msub>
<mml:mi>&#x3c9;</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mi mathvariant="bold-italic">W</mml:mi>
<mml:mo>&#x7c;</mml:mo>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3bc;</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
<mml:mo>,</mml:mo>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3a3;</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:mstyle>
</mml:mrow>
</mml:mrow>
</mml:mstyle>
</mml:mrow>
</mml:mrow>
</mml:mstyle>
<mml:mi>d</mml:mi>
<mml:msub>
<mml:mi>W</mml:mi>
<mml:mn>1</mml:mn>
</mml:msub>
<mml:mo>&#x22ef;</mml:mo>
<mml:mi>d</mml:mi>
<mml:msub>
<mml:mi>W</mml:mi>
<mml:mi>K</mml:mi>
</mml:msub>
<mml:mo>,</mml:mo>
</mml:mtd>
</mml:mtr>
<mml:mtr>
<mml:mtd>
<mml:mo>&#x3d;</mml:mo>
<mml:mstyle displaystyle="true">
<mml:munderover>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi>m</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>M</mml:mi>
</mml:munderover>
<mml:mrow>
<mml:msub>
<mml:mi>&#x3c9;</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
<mml:mrow>
<mml:mo>[</mml:mo>
<mml:mrow>
<mml:mstyle displaystyle="true">
<mml:mrow>
<mml:mo>&#x222b;</mml:mo>
<mml:mrow>
<mml:mo>&#x22ef;</mml:mo>
<mml:mstyle displaystyle="true">
<mml:mrow>
<mml:msubsup>
<mml:mo>&#x222b;</mml:mo>
<mml:mrow>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>&#x221e;</mml:mi>
</mml:mrow>
<mml:mi>W</mml:mi>
</mml:msubsup>
<mml:mrow>
<mml:mstyle displaystyle="true">
<mml:munderover>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi>m</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>M</mml:mi>
</mml:munderover>
<mml:mrow>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mi mathvariant="bold-italic">W</mml:mi>
<mml:mo>&#x7c;</mml:mo>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3bc;</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
<mml:mo>,</mml:mo>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3a3;</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:mstyle>
</mml:mrow>
</mml:mrow>
</mml:mstyle>
</mml:mrow>
</mml:mrow>
</mml:mstyle>
<mml:mi>d</mml:mi>
<mml:msub>
<mml:mi>W</mml:mi>
<mml:mn>1</mml:mn>
</mml:msub>
<mml:mo>&#x22ef;</mml:mo>
<mml:mi>d</mml:mi>
<mml:msub>
<mml:mi>W</mml:mi>
<mml:mi>K</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>]</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:mstyle>
<mml:mo>,</mml:mo>
</mml:mtd>
</mml:mtr>
<mml:mtr>
<mml:mtd>
<mml:mo>&#x3d;</mml:mo>
<mml:mstyle displaystyle="true">
<mml:munderover>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi>m</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>M</mml:mi>
</mml:munderover>
<mml:mrow>
<mml:msub>
<mml:mi>&#x3c9;</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
<mml:msub>
<mml:mi>F</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mi mathvariant="bold-italic">W</mml:mi>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:mstyle>
<mml:mo>.</mml:mo>
</mml:mtd>
</mml:mtr>
</mml:mtable>
</mml:math>
<label>(12)</label>
</disp-formula>
</p>
<p>Accordingly, the joint probability density function of node voltage <italic>V</italic> can be obtained by differentiating <xref ref-type="disp-formula" rid="e12">Eq. 12</xref>.<disp-formula id="e13">
<mml:math id="m22">
<mml:mtable>
<mml:mtr>
<mml:mtd>
<mml:mi>f</mml:mi>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mi>W</mml:mi>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:msup>
<mml:mo>&#x2202;</mml:mo>
<mml:mi>K</mml:mi>
</mml:msup>
</mml:mrow>
<mml:mrow>
<mml:mo>&#x2202;</mml:mo>
<mml:msub>
<mml:mi>W</mml:mi>
<mml:mn>1</mml:mn>
</mml:msub>
<mml:mo>&#x22ef;</mml:mo>
<mml:mo>&#x2202;</mml:mo>
<mml:msub>
<mml:mi>W</mml:mi>
<mml:mi>K</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mfrac>
<mml:mstyle displaystyle="true">
<mml:munderover>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi>m</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>M</mml:mi>
</mml:munderover>
<mml:mrow>
<mml:msub>
<mml:mi>&#x3c9;</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
<mml:msub>
<mml:mi>F</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mi>W</mml:mi>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:mstyle>
<mml:mo>,</mml:mo>
</mml:mtd>
</mml:mtr>
<mml:mtr>
<mml:mtd>
<mml:mo>&#x3d;</mml:mo>
<mml:mstyle displaystyle="true">
<mml:munderover>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi>m</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>M</mml:mi>
</mml:munderover>
<mml:mrow>
<mml:msub>
<mml:mi>&#x3c9;</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
<mml:mfrac>
<mml:mrow>
<mml:msup>
<mml:mo>&#x2202;</mml:mo>
<mml:mi>K</mml:mi>
</mml:msup>
</mml:mrow>
<mml:mrow>
<mml:mo>&#x2202;</mml:mo>
<mml:msub>
<mml:mi>W</mml:mi>
<mml:mn>1</mml:mn>
</mml:msub>
<mml:mo>&#x22ef;</mml:mo>
<mml:mo>&#x2202;</mml:mo>
<mml:msub>
<mml:mi>W</mml:mi>
<mml:mi>K</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mfrac>
<mml:msub>
<mml:mi>F</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mi>W</mml:mi>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:mstyle>
<mml:mo>,</mml:mo>
</mml:mtd>
</mml:mtr>
<mml:mtr>
<mml:mtd>
<mml:mo>&#x3d;</mml:mo>
<mml:mstyle displaystyle="true">
<mml:munderover>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi>m</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>M</mml:mi>
</mml:munderover>
<mml:mrow>
<mml:msub>
<mml:mi>&#x3c9;</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>m</mml:mi>
</mml:msub>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mi>W</mml:mi>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:mstyle>
<mml:mo>.</mml:mo>
</mml:mtd>
</mml:mtr>
</mml:mtable>
</mml:math>
<label>(13)</label>
</disp-formula>
</p>
<p>
<xref ref-type="disp-formula" rid="e12">Eqs 12</xref>, <xref ref-type="disp-formula" rid="e13">13</xref> are the node voltage joint CDF and joint PDF when the photovoltaic output power is modeled by GMM.</p>
</sec>
</sec>
<sec id="s4">
<title>4 Evaluation System of Distribution Network Planning Considering Power Flow Uncertainty</title>
<p>According to the analysis in <xref ref-type="sec" rid="s3">Section 3</xref>, the joint probability distribution density function of multi-node voltage and multi-section power flow is obtained to effectively describe the uncertainty of power flow. Then, combined with the severity function description and the active distribution network planning evaluation method based on probabilistic power flow analysis, three evaluation indexes are added in this section to describe the voltage and power flow fluctuations caused by photovoltaic access.</p>
<sec id="s4-1">
<title>4.1 New Evaluation Index of Distribution Network Planning Considering Distributed Photovoltaic Access</title>
<p>Under the influence of light intensity, the output power of the photovoltaic power station meets a certain probability distribution, which will lead to fluctuations in the voltage of key nodes in the power grid and the transmission power of key power flow section. Distributed photovoltaic grid connection may also cause the bus voltage of the power grid to deviate to varying degrees at different times. The degree of system voltage offset is an important factor in evaluating voltage quality. Excessive voltage offset may lead to &#x201c;voltage collapse&#x201d; and eventually large-scale power outage (<xref ref-type="bibr" rid="B28">Zhang et al., 2021</xref>). In addition, because the random fluctuation of line power flow is not considered, the distribution network planning evaluation based on traditional power flow will not accurately measure the risk. Therefore, in order to form a distribution network planning evaluation system that is suitable for distributed photovoltaic access, the aforementioned factors are added here, and the following evaluation indexes are defined:<list list-type="simple">
<list-item>
<p>1) The risk index of voltage over-limit <italic>Risk (V).</italic> In order to measure the voltage quality of the distribution network at the key bus under the condition of random fluctuating power output, based on the voltage joint cumulative distribution function obtained in <xref ref-type="sec" rid="s3">Section 3</xref>, the voltage out-of-limit risk index is defined as follows:</p>
</list-item>
</list>
<disp-formula id="e14">
<mml:math id="m23">
<mml:mrow>
<mml:mi>R</mml:mi>
<mml:mi>i</mml:mi>
<mml:mi>s</mml:mi>
<mml:mi>k</mml:mi>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mi>V</mml:mi>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mo>&#x3d;</mml:mo>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mi>V</mml:mi>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mi>S</mml:mi>
<mml:mi>e</mml:mi>
<mml:msub>
<mml:mi>v</mml:mi>
<mml:mrow>
<mml:mi>h</mml:mi>
<mml:mi>v</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi>V</mml:mi>
<mml:mrow>
<mml:mi>max</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mo>,</mml:mo>
</mml:mrow>
</mml:math>
<label>(14)</label>
</disp-formula>where <italic>F</italic>(<italic>V</italic>) represents the joint probability density function of multi-node voltage, <italic>Sev</italic>
<sub>
<italic>hv</italic>
</sub> (<italic>V</italic>
<sub>
<italic>max</italic>
</sub>) represents the severity function of voltage over-limit, which is defined as follows:<disp-formula id="e15">
<mml:math id="m24">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mi>e</mml:mi>
<mml:msub>
<mml:mi>v</mml:mi>
<mml:mrow>
<mml:mi>h</mml:mi>
<mml:mi>v</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi>V</mml:mi>
<mml:mrow>
<mml:mi>max</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mo>&#x3d;</mml:mo>
<mml:mrow>
<mml:mo>{</mml:mo>
<mml:mtable columnalign="left">
<mml:mtr>
<mml:mtd>
<mml:mfrac>
<mml:mrow>
<mml:mn>1.1</mml:mn>
<mml:mo>&#x2212;</mml:mo>
<mml:msub>
<mml:mi>V</mml:mi>
<mml:mrow>
<mml:mi>max</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mrow>
<mml:mn>1.1</mml:mn>
</mml:mrow>
</mml:mfrac>
<mml:mo>,</mml:mo>
<mml:msub>
<mml:mi>V</mml:mi>
<mml:mrow>
<mml:mi>max</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2265;</mml:mo>
<mml:mn>1.1</mml:mn>
</mml:mtd>
</mml:mtr>
<mml:mtr>
<mml:mtd>
<mml:mn>0</mml:mn>
<mml:mo>,</mml:mo>
<mml:mtext>&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;</mml:mtext>
<mml:msub>
<mml:mi>V</mml:mi>
<mml:mrow>
<mml:mi>max</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x3c;</mml:mo>
<mml:mn>1.1</mml:mn>
</mml:mtd>
</mml:mtr>
</mml:mtable>
</mml:mrow>
<mml:mo>,</mml:mo>
</mml:mrow>
</mml:math>
<label>(15)</label>
</disp-formula>where <italic>V</italic>
<sub>max</sub> &#x3d; max{<italic>V</italic>
<sub>
<italic>1</italic>
</sub>,<italic>V</italic>
<sub>
<italic>2</italic>
</sub>,&#x2026;<italic>V</italic>
<sub>
<italic>k</italic>
</sub>}, when calculating the severity of the voltage of <italic>k</italic> nodes crossing the limit at the same time, select the node voltage with the largest deviation from the rated voltage to replace it with the severity function.<list list-type="simple">
<list-item>
<p>2) The index of voltage deviation BVDI. The calculation formula of voltage deviation index is as follows:</p>
</list-item>
</list>
<disp-formula id="e16">
<mml:math id="m25">
<mml:mrow>
<mml:mi>B</mml:mi>
<mml:mi>V</mml:mi>
<mml:mi>D</mml:mi>
<mml:mi>I</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:msqrt>
<mml:mrow>
<mml:mfrac>
<mml:mn>1</mml:mn>
<mml:mrow>
<mml:mi>m</mml:mi>
<mml:mo>&#x2212;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
</mml:mfrac>
<mml:mstyle displaystyle="true">
<mml:msubsup>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>m</mml:mi>
</mml:msubsup>
<mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi>U</mml:mi>
<mml:mi>i</mml:mi>
</mml:msub>
<mml:mo>&#x2212;</mml:mo>
<mml:mrow>
<mml:mover accent="true">
<mml:mi>U</mml:mi>
<mml:mo stretchy="true">&#xaf;</mml:mo>
</mml:mover>
</mml:mrow>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msup>
</mml:mrow>
</mml:mstyle>
</mml:mrow>
</mml:msqrt>
<mml:mo>,</mml:mo>
</mml:mrow>
</mml:math>
<label>(16)</label>
</disp-formula>where <italic>U</italic>
<sub>
<italic>i</italic>
</sub> represents the voltage observation value of the <italic>i</italic>th time, which is obtained by sampling calculation; <inline-formula id="inf10">
<mml:math id="m26">
<mml:mrow>
<mml:mover accent="true">
<mml:mi>U</mml:mi>
<mml:mo stretchy="true">&#xaf;</mml:mo>
</mml:mover>
</mml:mrow>
</mml:math>
</inline-formula> represents the average value of sampling voltage; <italic>m</italic> represents the sample size of the sampling survey. The value of BVDI represents the concentration or dispersion of power grid bus voltage distribution. The smaller the voltage distribution index, the more concentrated the power grid bus voltage distribution and better power quality.<list list-type="simple">
<list-item>
<p>3) The risk index of power flow over-limit <italic>Risk (P).</italic> By analogy with the voltage out-of-limit risk index, based on the joint cumulative distribution function obtained in <xref ref-type="sec" rid="s3">Section 3</xref>, the voltage out-of-limit risk index is defined as follows:</p>
</list-item>
</list>
<disp-formula id="e17">
<mml:math id="m27">
<mml:mrow>
<mml:mi>R</mml:mi>
<mml:mi>i</mml:mi>
<mml:mi>s</mml:mi>
<mml:mi>k</mml:mi>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mi>P</mml:mi>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mo>&#x3d;</mml:mo>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mi>P</mml:mi>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mi>S</mml:mi>
<mml:mi>e</mml:mi>
<mml:msub>
<mml:mi>v</mml:mi>
<mml:mrow>
<mml:mi>o</mml:mi>
<mml:mi>p</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mi mathvariant="normal">&#x394;</mml:mi>
<mml:mi>P</mml:mi>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mrow>
<mml:mi>max</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mo>,</mml:mo>
</mml:mrow>
</mml:math>
<label>(17)</label>
</disp-formula>where <italic>F</italic>(<italic>P</italic>) represents the joint probability density function of line power flow and <inline-formula id="inf11">
<mml:math id="m28">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mi>e</mml:mi>
<mml:msub>
<mml:mi>v</mml:mi>
<mml:mrow>
<mml:mi>o</mml:mi>
<mml:mi>p</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mi mathvariant="normal">&#x394;</mml:mi>
<mml:mi>P</mml:mi>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mrow>
<mml:mi>max</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula> represents the severity function of line power flow out-of-limit. The specific definition is shown in <xref ref-type="disp-formula" rid="e18">Eq. 18</xref>.<disp-formula id="e18">
<mml:math id="m29">
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mi>e</mml:mi>
<mml:msub>
<mml:mi>v</mml:mi>
<mml:mrow>
<mml:mi>o</mml:mi>
<mml:mi>p</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mi mathvariant="normal">&#x394;</mml:mi>
<mml:mi>P</mml:mi>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mrow>
<mml:mi>max</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mo>&#x3d;</mml:mo>
<mml:mrow>
<mml:mo>{</mml:mo>
<mml:mtable columnalign="left">
<mml:mtr>
<mml:mtd>
<mml:mi>max</mml:mi>
<mml:mrow>
<mml:mo>{</mml:mo>
<mml:mrow>
<mml:mi>P</mml:mi>
<mml:mo>&#x2212;</mml:mo>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mi>n</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mo>}</mml:mo>
</mml:mrow>
<mml:mo>,</mml:mo>
<mml:mtext>&#xa0;&#xa0;&#xa0;</mml:mtext>
<mml:mi>P</mml:mi>
<mml:mo>&#x3e;</mml:mo>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mi>n</mml:mi>
</mml:msub>
</mml:mtd>
</mml:mtr>
<mml:mtr>
<mml:mtd>
<mml:mn>0</mml:mn>
<mml:mo>,</mml:mo>
<mml:mtext>&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;&#xa0;</mml:mtext>
<mml:mi>P</mml:mi>
<mml:mo>&#x2264;</mml:mo>
<mml:msub>
<mml:mi>P</mml:mi>
<mml:mi>n</mml:mi>
</mml:msub>
</mml:mtd>
</mml:mtr>
</mml:mtable>
</mml:mrow>
<mml:mo>,</mml:mo>
</mml:mrow>
</mml:math>
<label>(18)</label>
</disp-formula>where max{<italic>P-P</italic>
<sub>
<italic>n</italic>
</sub>} is the maximum deviation between the line power flow and the rated transmission power. When the power flow of all lines is not greater than the rated transmission power <italic>P</italic> &#x2264; <italic>P</italic>
<sub>
<italic>n</italic>
</sub>, the severity function value is 0, otherwise, the maximum value of the power flow deviation is taken.</p>
</sec>
<sec id="s4-2">
<title>4.2 Comprehensive Evaluation Index System of Distribution Network Planning Considering Distributed Photovoltaic Access</title>
<p>The voltage out-of-limit risk index, voltage deviation index, and line overload risk index are incorporated into the existing comprehensive evaluation index system of distribution network planning, that is, considering reliability, economy, safety, and adaptability at the same time, a three-tier distribution network index evaluation system considering distributed photovoltaic access is formed, as shown in <xref ref-type="fig" rid="F1">Figure 1</xref>.</p>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption>
<p>Index evaluation system of distributed photovoltaic power generation access to the distribution network.</p>
</caption>
<graphic xlink:href="fenrg-10-892579-g001.tif"/>
</fig>
<p>In addition to the three indicators defined in <xref ref-type="sec" rid="s4-1">Section 4.1</xref>, the definitions of relevant traditional indicators in the figure are shown in the study by (<xref ref-type="bibr" rid="B5">Guo et al. 2021</xref>), and the weight of indicators shown in <xref ref-type="fig" rid="F1">Figure 1</xref> is calculated by the analytic hierarchy process.<list list-type="simple">
<list-item>
<p>1) Establish the importance matrix of the benchmark layer and the index layer under each benchmark layer. When constructing the importance matrix, the relative importance of the elements of each layer is quantified by numbers 1&#x223c;9, and finally the importance matrix <inline-formula id="inf12">
<mml:math id="m30">
<mml:mrow>
<mml:mi mathvariant="bold">P</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi>p</mml:mi>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mi>j</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mrow>
<mml:mi>n</mml:mi>
<mml:mo>&#xd7;</mml:mo>
<mml:mi>n</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> is obtained. According to the <xref ref-type="fig" rid="F1">Figure 1</xref>, there are four elements of the benchmark layer in the study. Therefore, four important matrices needed to be formed in this study, that is the attribute of the criterion layer to the target layer <inline-formula id="inf13">
<mml:math id="m31">
<mml:mrow>
<mml:mi mathvariant="bold">M</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi>m</mml:mi>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mi>j</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mrow>
<mml:mn>4</mml:mn>
<mml:mo>&#xd7;</mml:mo>
<mml:mn>4</mml:mn>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>, the power supply reliability <inline-formula id="inf14">
<mml:math id="m32">
<mml:mrow>
<mml:mi mathvariant="bold">A</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi>a</mml:mi>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mi>j</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mrow>
<mml:mn>4</mml:mn>
<mml:mo>&#xd7;</mml:mo>
<mml:mn>4</mml:mn>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>, voltage quality <inline-formula id="inf15">
<mml:math id="m33">
<mml:mrow>
<mml:mi mathvariant="bold">B</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi>b</mml:mi>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mi>j</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mrow>
<mml:mn>3</mml:mn>
<mml:mo>&#xd7;</mml:mo>
<mml:mn>3</mml:mn>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>, adaptability <inline-formula id="inf16">
<mml:math id="m34">
<mml:mrow>
<mml:mi mathvariant="bold">C</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi>c</mml:mi>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mi>j</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mrow>
<mml:mn>3</mml:mn>
<mml:mo>&#xd7;</mml:mo>
<mml:mn>3</mml:mn>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>, and economy <inline-formula id="inf17">
<mml:math id="m35">
<mml:mrow>
<mml:mi mathvariant="bold">D</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mrow>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi>d</mml:mi>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mi>j</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
<mml:mrow>
<mml:mn>2</mml:mn>
<mml:mo>&#xd7;</mml:mo>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>.</p>
</list-item>
<list-item>
<p>2) Calculate the weight coefficient of all attributes in the criterion layer to the importance matrix <bold>M</bold> in the target layer based on the arithmetic average method. Similarly, the importance matrix of <bold>A</bold>, <bold>B</bold>, <bold>C</bold>, and <bold>D</bold> are calculated. Then multiply the weight of each element of the index layer by the weight of the corresponding reference layer, and the combined weights W are obtained.</p>
</list-item>
<list-item>
<p>3) Calculate the comprehensive evaluation value of the distribution network. Based on the combined weights and index initial score <bold>S</bold>, the comprehensive score TS of distribution network planning is calculated as follows:</p>
</list-item>
</list>
<disp-formula id="e19">
<mml:math id="m36">
<mml:mrow>
<mml:mi>TS</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mstyle displaystyle="true">
<mml:munderover>
<mml:mo>&#x2211;</mml:mo>
<mml:mrow>
<mml:mi>j</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
<mml:mi>&#x3bb;</mml:mi>
</mml:munderover>
<mml:mrow>
<mml:msub>
<mml:mi>S</mml:mi>
<mml:mi>j</mml:mi>
</mml:msub>
<mml:msub>
<mml:mi>W</mml:mi>
<mml:mi>j</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mstyle>
<mml:mo>,</mml:mo>
</mml:mrow>
</mml:math>
<label>(19)</label>
</disp-formula>where <italic>S</italic>
<sub>
<italic>j</italic>
</sub> represents the score of the <italic>j</italic>th index of the index layer, <italic>W</italic>
<sub>
<italic>j</italic>
</sub> represents the comprehensive weight of the <italic>j</italic>th subordinate index of the index layer, and &#x3bb; represents the number of elements contained in the index layer of the index system.</p>
</sec>
<sec id="s4-3">
<title>4.3 Flow Chart of Comprehensive Evaluation of Active Distribution Network Planning Based on Probabilistic Power Flow Analysis</title>
<p>In summary, this section forms the following flow chart of comprehensive evaluation score of active distribution network planning based on probabilistic power flow analysis, as shown in <xref ref-type="fig" rid="F2">Figure 2</xref>.</p>
<fig id="F2" position="float">
<label>FIGURE 2</label>
<caption>
<p>Flow chart of the comprehensive evaluation of the distribution network.</p>
</caption>
<graphic xlink:href="fenrg-10-892579-g002.tif"/>
</fig>
</sec>
</sec>
<sec id="s5">
<title>5 Simulation Analysis</title>
<sec id="s5-1">
<title>5.1 Simulation System</title>
<p>In order to verify the rationality of the active distribution network planning evaluation method based on probabilistic power flow analysis proposed in this study, two areas, M and N, of an urban distribution network in China are used as simulation examples in this section. The distribution network in this area is connected with a large number of distributed photovoltaics. The system structure diagram is shown in <xref ref-type="fig" rid="F3">Figure 3</xref>, and the dotted line in the figure indicates that it is not directly connected.</p>
<fig id="F3" position="float">
<label>FIGURE 3</label>
<caption>
<p>Distribution network system diagram of an urban area.</p>
</caption>
<graphic xlink:href="fenrg-10-892579-g003.tif"/>
</fig>
</sec>
<sec id="s5-2">
<title>5.2 Simulation Analysis</title>
<sec id="s5-2-1">
<title>5.2.1 Probabilistic Power Flow Analysis</title>
<p>According to the flow chart shown in <xref ref-type="fig" rid="F2">Figure 2</xref>, the output power data of the photovoltaic power station was obtained first, which comes from the real data collected in areas M and N. According to the parameter determination steps of the Gaussian mixture model based on the improved particle swarm optimization algorithm shown in <xref ref-type="sec" rid="s2-2">Section 2.2</xref>, let the number of sub-components of the Gaussian mixture model be two, and the solution of the weight of the probability density function of photovoltaic output in area M are <inline-formula id="inf18">
<mml:math id="m37">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="italic">&#x3c9;</mml:mi>
<mml:mn>1</mml:mn>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0.4817</mml:mn>
</mml:mrow>
</mml:math>
</inline-formula>, <inline-formula id="inf19">
<mml:math id="m38">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="italic">&#x3c9;</mml:mi>
<mml:mn>2</mml:mn>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0.5183</mml:mn>
</mml:mrow>
</mml:math>
</inline-formula>; weight of probability density function of photovoltaic output in area N is <inline-formula id="inf20">
<mml:math id="m39">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="italic">&#x3c9;</mml:mi>
<mml:mn>1</mml:mn>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0.2721</mml:mn>
</mml:mrow>
</mml:math>
</inline-formula> and <inline-formula id="inf21">
<mml:math id="m40">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="italic">&#x3c9;</mml:mi>
<mml:mn>2</mml:mn>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0.7279</mml:mn>
</mml:mrow>
</mml:math>
</inline-formula>. The parameter expectation and covariance results of the Gaussian mixture model are shown in <xref ref-type="table" rid="T1">Table 1</xref>. &#x3bc;<sub>m1</sub> and &#x3a3;<sub>m1</sub> represent the expectation vector and covariance matrix of the first Gaussian sub-component, &#x3bc;<sub>m2</sub> and &#x3a3;<sub>m2</sub> represent the expectation vector and covariance matrix of the second Gaussian sub-component. The non-diagonal elements of two covariance matrices can describe the correlation between the outputs of two photovoltaic power stations.</p>
<table-wrap id="T1" position="float">
<label>TABLE 1</label>
<caption>
<p>Gaussian mixture model parameter results.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="left"/>
<th align="center">
<inline-formula id="inf22">
<mml:math id="m41">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3bc;</mml:mi>
<mml:mrow>
<mml:mi mathvariant="italic">m</mml:mi>
<mml:mi mathvariant="normal">1</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</th>
<th align="center">
<inline-formula id="inf23">
<mml:math id="m42">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3bc;</mml:mi>
<mml:mrow>
<mml:mi mathvariant="italic">m</mml:mi>
<mml:mi mathvariant="normal">2</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</th>
<th align="center">
<inline-formula id="inf24">
<mml:math id="m43">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3a3;</mml:mi>
<mml:mrow>
<mml:mi mathvariant="italic">m</mml:mi>
<mml:mi mathvariant="normal">1</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</th>
<th align="center">
<inline-formula id="inf25">
<mml:math id="m44">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="bold-italic">&#x3a3;</mml:mi>
<mml:mrow>
<mml:mi mathvariant="italic">m</mml:mi>
<mml:mi mathvariant="normal">2</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>
</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">Area M</td>
<td align="center">
<inline-formula id="inf26">
<mml:math id="m45">
<mml:mrow>
<mml:mrow>
<mml:mo>[</mml:mo>
<mml:mrow>
<mml:mtable>
<mml:mtr>
<mml:mtd>
<mml:mrow>
<mml:mn>0.4268</mml:mn>
</mml:mrow>
</mml:mtd>
</mml:mtr>
<mml:mtr>
<mml:mtd>
<mml:mrow>
<mml:mn>0.7194</mml:mn>
</mml:mrow>
</mml:mtd>
</mml:mtr>
</mml:mtable>
</mml:mrow>
<mml:mo>]</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="center">
<inline-formula id="inf27">
<mml:math id="m46">
<mml:mrow>
<mml:mrow>
<mml:mo>[</mml:mo>
<mml:mrow>
<mml:mtable>
<mml:mtr>
<mml:mtd>
<mml:mrow>
<mml:mn>0.2448</mml:mn>
</mml:mrow>
</mml:mtd>
</mml:mtr>
<mml:mtr>
<mml:mtd>
<mml:mrow>
<mml:mn>0.5289</mml:mn>
</mml:mrow>
</mml:mtd>
</mml:mtr>
</mml:mtable>
</mml:mrow>
<mml:mo>]</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="center">
<inline-formula id="inf28">
<mml:math id="m47">
<mml:mrow>
<mml:mrow>
<mml:mo>[</mml:mo>
<mml:mrow>
<mml:mtable>
<mml:mtr>
<mml:mtd>
<mml:mrow>
<mml:mtext>0</mml:mtext>
<mml:mtext>.</mml:mtext>
<mml:mn>0087</mml:mn>
<mml:mtext>&#xa0;</mml:mtext>
</mml:mrow>
</mml:mtd>
<mml:mtd>
<mml:mrow>
<mml:mtext>0</mml:mtext>
<mml:mtext>.</mml:mtext>
<mml:mn>0080</mml:mn>
</mml:mrow>
</mml:mtd>
</mml:mtr>
<mml:mtr>
<mml:mtd>
<mml:mrow>
<mml:mtext>0</mml:mtext>
<mml:mtext>.</mml:mtext>
<mml:mn>0080</mml:mn>
</mml:mrow>
</mml:mtd>
<mml:mtd>
<mml:mrow>
<mml:mtext>0</mml:mtext>
<mml:mtext>.</mml:mtext>
<mml:mn>0183</mml:mn>
</mml:mrow>
</mml:mtd>
</mml:mtr>
</mml:mtable>
</mml:mrow>
<mml:mo>]</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="center">
<inline-formula id="inf29">
<mml:math id="m48">
<mml:mrow>
<mml:mrow>
<mml:mo>[</mml:mo>
<mml:mrow>
<mml:mtable>
<mml:mtr>
<mml:mtd>
<mml:mrow>
<mml:mtext>0</mml:mtext>
<mml:mtext>.</mml:mtext>
<mml:mn>0151</mml:mn>
<mml:mtext>&#xa0;</mml:mtext>
</mml:mrow>
</mml:mtd>
<mml:mtd>
<mml:mrow>
<mml:mtext>0</mml:mtext>
<mml:mtext>.</mml:mtext>
<mml:mn>0059</mml:mn>
</mml:mrow>
</mml:mtd>
</mml:mtr>
<mml:mtr>
<mml:mtd>
<mml:mrow>
<mml:mtext>0</mml:mtext>
<mml:mtext>.</mml:mtext>
<mml:mn>0059</mml:mn>
</mml:mrow>
</mml:mtd>
<mml:mtd>
<mml:mrow>
<mml:mtext>0</mml:mtext>
<mml:mtext>.</mml:mtext>
<mml:mn>0097</mml:mn>
</mml:mrow>
</mml:mtd>
</mml:mtr>
</mml:mtable>
</mml:mrow>
<mml:mo>]</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
</tr>
<tr>
<td align="left">Area N</td>
<td align="center">
<inline-formula id="inf30">
<mml:math id="m49">
<mml:mrow>
<mml:mrow>
<mml:mo>[</mml:mo>
<mml:mtable columnalign="left">
<mml:mtr>
<mml:mtd>
<mml:mn>0.2506</mml:mn>
</mml:mtd>
</mml:mtr>
<mml:mtr>
<mml:mtd>
<mml:mn>0.5390</mml:mn>
</mml:mtd>
</mml:mtr>
</mml:mtable>
<mml:mo>]</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="center">
<inline-formula id="inf31">
<mml:math id="m50">
<mml:mrow>
<mml:mrow>
<mml:mo>[</mml:mo>
<mml:mrow>
<mml:mtable>
<mml:mtr>
<mml:mtd>
<mml:mrow>
<mml:mn>0.6040</mml:mn>
</mml:mrow>
</mml:mtd>
</mml:mtr>
<mml:mtr>
<mml:mtd>
<mml:mrow>
<mml:mn>0.8786</mml:mn>
</mml:mrow>
</mml:mtd>
</mml:mtr>
</mml:mtable>
</mml:mrow>
<mml:mo>]</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="center">
<inline-formula id="inf32">
<mml:math id="m51">
<mml:mrow>
<mml:mrow>
<mml:mo>[</mml:mo>
<mml:mrow>
<mml:mtable>
<mml:mtr>
<mml:mtd>
<mml:mrow>
<mml:mtext>0</mml:mtext>
<mml:mtext>.</mml:mtext>
<mml:mn>0158</mml:mn>
<mml:mtext>&#xa0;</mml:mtext>
</mml:mrow>
</mml:mtd>
<mml:mtd>
<mml:mrow>
<mml:mtext>0</mml:mtext>
<mml:mtext>.</mml:mtext>
<mml:mn>0047</mml:mn>
</mml:mrow>
</mml:mtd>
</mml:mtr>
<mml:mtr>
<mml:mtd>
<mml:mrow>
<mml:mtext>0</mml:mtext>
<mml:mtext>.</mml:mtext>
<mml:mn>0047</mml:mn>
</mml:mrow>
</mml:mtd>
<mml:mtd>
<mml:mrow>
<mml:mtext>0</mml:mtext>
<mml:mtext>.</mml:mtext>
<mml:mn>0032</mml:mn>
</mml:mrow>
</mml:mtd>
</mml:mtr>
</mml:mtable>
</mml:mrow>
<mml:mo>]</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
<td align="center">
<inline-formula id="inf33">
<mml:math id="m52">
<mml:mrow>
<mml:mrow>
<mml:mo>[</mml:mo>
<mml:mrow>
<mml:mtable>
<mml:mtr>
<mml:mtd>
<mml:mrow>
<mml:mtext>0</mml:mtext>
<mml:mtext>.</mml:mtext>
<mml:mn>0091</mml:mn>
<mml:mtext>&#xa0;</mml:mtext>
</mml:mrow>
</mml:mtd>
<mml:mtd>
<mml:mrow>
<mml:mtext>0</mml:mtext>
<mml:mtext>.</mml:mtext>
<mml:mn>0083</mml:mn>
</mml:mrow>
</mml:mtd>
</mml:mtr>
<mml:mtr>
<mml:mtd>
<mml:mrow>
<mml:mtext>0</mml:mtext>
<mml:mtext>.</mml:mtext>
<mml:mn>0083</mml:mn>
</mml:mrow>
</mml:mtd>
<mml:mtd>
<mml:mrow>
<mml:mtext>0</mml:mtext>
<mml:mtext>.</mml:mtext>
<mml:mn>0190</mml:mn>
</mml:mrow>
</mml:mtd>
</mml:mtr>
</mml:mtable>
</mml:mrow>
<mml:mo>]</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:math>
</inline-formula>
</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>Calculate the node voltage probability density distribution function according to <xref ref-type="disp-formula" rid="e11">Eqs 11</xref>&#x2013;<xref ref-type="disp-formula" rid="e13">13</xref>. The Monte Carlo algorithm (MCS) has high calculation accuracy, but it is limited by the calculation speed, which is used to compare the advantages and disadvantages of different methods. This section obtains the probability power flow distribution of node voltage and line flow in the system based on the EM algorithm and the method proposed in this study and compares them with the MCS algorithm to illustrate their accuracy. First, the probability distribution calculation of node voltage is used to verify the accuracy of the proposed improved algorithm. In this section, node M1 in area M is selected as the observation point to obtain the corresponding voltage probability density distribution. The results are shown in <xref ref-type="fig" rid="F4">Figure 4</xref>.</p>
<fig id="F4" position="float">
<label>FIGURE 4</label>
<caption>
<p>The voltage amplitude probability distribution of bus M<sub>1</sub>. <bold>(A)</bold> The voltage amplitude probability density function of bus M<sub>1</sub>. <bold>(B)</bold> The cumulative distribution function of voltage amplitude at bus M<sub>1</sub>.</p>
</caption>
<graphic xlink:href="fenrg-10-892579-g004.tif"/>
</fig>
<p>According to <xref ref-type="fig" rid="F4">Figure 4</xref>, the black line is obtained by MCS. The red line is obtained by the proposed improved optimal particle swarm optimization algorithm. The blue line is obtained by the traditional EM method. It can be obviously observed from <xref ref-type="fig" rid="F4">Figure 4</xref> that the proposed method is more consistent with MCS compared with the traditional EM method. The average root mean square error and maximum absolute error (<xref ref-type="bibr" rid="B24">Yang et al., 2017</xref>) when calculating the probability distribution of voltage amplitude of bus 5 in <xref ref-type="fig" rid="F4">Figure 4</xref> based on the EM algorithm are 0.044 and 0.305, respectively, while the two error indices are reduced to 0.000295 and 0.0472, respectively, based on the method proposed in this study, which verifies the superiority of the method proposed in this study in improving the modeling accuracy of GMM. From <xref ref-type="fig" rid="F4">Figure 4A</xref>, the PDF is maximum in the interval 0.995-1, which represents that the node voltage has the highest probability of belonging to this interval. From <xref ref-type="fig" rid="F4">Figure 4B</xref>, the randomness of photovoltaic output makes the node voltage fluctuate between 0.98 and 1.02. In other words, the probability that the voltage amplitude is less than 1.02 is 1, and the voltage amplitude does not exceed its limit. In terms of calculation time, the analytical method proposed in this study takes 0.053 s and the MCS method takes 24.43 s, which proves that the calculation efficiency of this method is better than that of MCS.</p>
<p>Based on the more accurate GMM proposed in this study, it has higher accuracy in describing the randomness of photovoltaic output, so that a more accurate node voltage out-of-limit index can be established, and finally, a more accurate voltage quality evaluation index of active distribution network planning can be obtained.</p>
<p>The joint probability density of line power flow can be used to describe the probability that multiple random variables are in the same state. Here, it is used to evaluate the probability that two or more line of power flows cross the limit at the same time.</p>
<p>According to <xref ref-type="fig" rid="F5">Figure 5</xref>, the yellow area represents the area with the largest probability density of power flow combination of the two lines, and the blue area represents the part with the smallest probability density. Take <xref ref-type="fig" rid="F5">Figure 5A</xref> as an example, that is, in the measured output power time interval of a photovoltaic power station, the active power flow on lines LM1 and LM2 in area M is mostly concentrated in the yellow area. Due to the limitation of dimension, it is difficult to show the joint power flow probability density distribution of three or more lines in the form of a diagram.</p>
<fig id="F5" position="float">
<label>FIGURE 5</label>
<caption>
<p>Joint probability density distribution of power flow of regional important lines. <bold>(A)</bold> The joint probability density of the line LM1 and the line LM2 in area M. <bold>(B)</bold> The joint probability density of the line LN1 and the line LN2 in area N.</p>
</caption>
<graphic xlink:href="fenrg-10-892579-g005.tif"/>
</fig>
</sec>
<sec id="s5-2-2">
<title>5.2.2 Comprehensive Evaluation Index</title>
<p>According to <xref ref-type="fig" rid="F5">Figure 5</xref>, the joint probability density distribution of power flow in multiple lines of areas M and N can be obtained. In order to verify the proposed evaluation method for distribution network planning and the randomness and correlation of photovoltaic output, according to the Gaussian mixture model of the output power of photovoltaic power plants in M area and N area established in <xref ref-type="table" rid="T1">Table 1</xref>, the joint probability density function of the voltage at the nodes N1&#x2013;N5 and nodes M1&#x2013;M5 is calculated respectively. Combined with the definition of severity function in <xref ref-type="disp-formula" rid="e15">Eq 15</xref>, <xref ref-type="disp-formula" rid="e18">18</xref>, we calculated the novel index of distribution network planning evaluation according to <xref ref-type="disp-formula" rid="e14">Eq 14</xref>, <xref ref-type="disp-formula" rid="e16">16</xref>, <xref ref-type="disp-formula" rid="e17">17</xref>, and the results are shown in <xref ref-type="table" rid="T2">Table 2</xref> below.</p>
<table-wrap id="T2" position="float">
<label>TABLE 2</label>
<caption>
<p>Evaluation index results of distribution network for photovoltaic access.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="left"/>
<th align="center">The index of voltage deviation</th>
<th align="center">The risk index of voltage over-limit</th>
<th align="center">The risk index of tidal current section over-limit</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">Area M</td>
<td align="char" char=".">0.027</td>
<td align="char" char=".">0.045</td>
<td align="char" char=".">0.062</td>
</tr>
<tr>
<td align="left">Area N</td>
<td align="char" char=".">0.015</td>
<td align="char" char=".">0.033</td>
<td align="char" char=".">0.056</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>The three indicators in <xref ref-type="table" rid="T2">Table 2</xref> are equivalently transformed according to the percentage system, and the rest of the indicators in the indicator system in <xref ref-type="fig" rid="F1">Figure 1</xref> are scored by experts. Taking the sum of the index scores of the two areas as the benchmark, the percentage system scores are converted to obtain the relative scores of all the indicators. The results are shown in <xref ref-type="table" rid="T3">Table 3</xref>.</p>
<table-wrap id="T3" position="float">
<label>TABLE 3</label>
<caption>
<p>Relative scores of all indicators.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th rowspan="2" align="left">Datum layer</th>
<th rowspan="2" align="center">Index</th>
<th colspan="2" align="center">Weight</th>
</tr>
<tr>
<th align="center">Area M</th>
<th align="center">Area N</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td rowspan="4" align="left">Power supply reliability</td>
<td align="left">A1. Average outage frequency of customers</td>
<td align="char" char=".">50.03</td>
<td align="char" char=".">49.97</td>
</tr>
<tr>
<td align="left">A2. Average interruption hours of customers</td>
<td align="char" char=".">50.57</td>
<td align="char" char=".">49.43</td>
</tr>
<tr>
<td align="left">A3. Reliability rate of power supply</td>
<td align="char" char=".">50.15</td>
<td align="char" char=".">49.85</td>
</tr>
<tr>
<td align="left">A4. Key cross-section tidal risk index</td>
<td align="char" char=".">47.46</td>
<td align="char" char=".">52.54</td>
</tr>
<tr>
<td rowspan="3" align="left">Voltage quality</td>
<td align="left">B1. Comprehensive voltage qualification</td>
<td align="char" char=".">41.28</td>
<td align="char" char=".">58.72</td>
</tr>
<tr>
<td align="left">B2. Voltage deviation</td>
<td align="char" char=".">35.71</td>
<td align="char" char=".">64.29</td>
</tr>
<tr>
<td align="left">B3. Bus voltage over-limit risk index</td>
<td align="char" char=".">42.31</td>
<td align="char" char=".">57.69</td>
</tr>
<tr>
<td rowspan="3" align="left">Adaptability</td>
<td align="left">C1. Expansion margin</td>
<td align="char" char=".">48.90</td>
<td align="char" char=".">51.10</td>
</tr>
<tr>
<td align="left">C2. Power supply capacity margin</td>
<td align="char" char=".">54.77</td>
<td align="char" char=".">45.23</td>
</tr>
<tr>
<td align="left">C3. Expandability</td>
<td align="char" char=".">50.26</td>
<td align="char" char=".">49.74</td>
</tr>
<tr>
<td rowspan="2" align="left">Economy</td>
<td align="left">D1. Total investment cost</td>
<td align="char" char=".">60.56</td>
<td align="char" char=".">39.44</td>
</tr>
<tr>
<td align="left">D2. Ratio of line loss</td>
<td align="char" char=".">48.08</td>
<td align="char" char=".">51.92</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>According to the distribution network index evaluation system shown in <xref ref-type="fig" rid="F1">Figure 1</xref>, the weight of the reference layer, the weight of the index layer, and the comprehensive weight of the two areas are calculated respectively based on the analytic hierarchy process. The results are shown in <xref ref-type="table" rid="T4">Table 4</xref>.</p>
<table-wrap id="T4" position="float">
<label>TABLE 4</label>
<caption>
<p>Calculation results of benchmark layer weight, index layer weight, and comprehensive weight.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="left">Datum layer</th>
<th align="center">Weight</th>
<th align="center">Index</th>
<th align="center">Weight</th>
<th align="center">Comprehensive weight</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td rowspan="4" align="left">Power supply reliability</td>
<td rowspan="4" align="char" char=".">0.3798</td>
<td align="left">A1. Average outage frequency of users</td>
<td align="char" char=".">0.2148</td>
<td align="char" char=".">0.0816</td>
</tr>
<tr>
<td align="left">A2. Average interruption hours of customers</td>
<td align="char" char=".">0.2217</td>
<td align="char" char=".">0.0842</td>
</tr>
<tr>
<td align="left">A3. Reliability rate of power supply</td>
<td align="char" char=".">0.2785</td>
<td align="char" char=".">0.1058</td>
</tr>
<tr>
<td align="left">A4. Key cross-section tidal risk index</td>
<td align="char" char=".">0.2850</td>
<td align="char" char=".">0.1082</td>
</tr>
<tr>
<td rowspan="3" align="left">Voltage quality</td>
<td rowspan="3" align="char" char=".">0.3757</td>
<td align="left">B1. Comprehensive voltage qualification</td>
<td align="char" char=".">0.3734</td>
<td align="char" char=".">0.1403</td>
</tr>
<tr>
<td align="left">B2. Voltage deviation</td>
<td align="char" char=".">0.2533</td>
<td align="char" char=".">0.0952</td>
</tr>
<tr>
<td align="left">B3. Bus voltage over-limit risk index</td>
<td align="char" char=".">0.3733</td>
<td align="char" char=".">0.1402</td>
</tr>
<tr>
<td rowspan="3" align="left">Adaptability</td>
<td rowspan="3" align="char" char=".">0.1142</td>
<td align="left">C1. Expansion margin</td>
<td align="char" char=".">0.5660</td>
<td align="char" char=".">0.0646</td>
</tr>
<tr>
<td align="left">C2. Power supply capacity margin</td>
<td align="char" char=".">0.2826</td>
<td align="char" char=".">0.0323</td>
</tr>
<tr>
<td align="left">C3. Expandability</td>
<td align="char" char=".">0.1514</td>
<td align="char" char=".">0.0173</td>
</tr>
<tr>
<td rowspan="2" align="left">Economy</td>
<td rowspan="2" align="char" char=".">0.1303</td>
<td align="left">D1. Total investment cost</td>
<td align="char" char=".">0.3465</td>
<td align="char" char=".">0.0451</td>
</tr>
<tr>
<td align="left">D2. Ratio of line loss</td>
<td align="char" char=".">0.6535</td>
<td align="char" char=".">0.0852</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>The final comprehensive evaluation score of the two regional distribution networks is calculated based on <xref ref-type="disp-formula" rid="e19">Eq. 19</xref>, as shown in <xref ref-type="table" rid="T5">Table 5</xref> below.</p>
<table-wrap id="T5" position="float">
<label>TABLE 5</label>
<caption>
<p>Comprehensive score of the two phases of the project.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="left"/>
<th align="center">Area M</th>
<th align="center">Area N</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">Power supply reliability</td>
<td align="char" char=".">18.7815</td>
<td align="char" char=".">19.1985</td>
</tr>
<tr>
<td align="left">Voltage quality</td>
<td align="char" char=".">15.1230</td>
<td align="char" char=".">22.4470</td>
</tr>
<tr>
<td align="left">Adaptability</td>
<td align="char" char=".">5.7975</td>
<td align="char" char=".">5.6225</td>
</tr>
<tr>
<td align="left">Economy</td>
<td align="char" char=".">6.8276</td>
<td align="char" char=".">6.2023</td>
</tr>
<tr>
<td align="left">Comprehensive index score</td>
<td align="char" char=".">46.5296</td>
<td align="char" char=".">53.4703</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>According to the <xref ref-type="table" rid="T5">Table 5</xref>, compared with the distribution network in the area M, the energy storage unit is equipped in the area N distribution network, which alleviates the impact of the fluctuation of the output of the photovoltaic power station on the power grid to a certain extent and improves the power supply quality and safety. The comprehensive score of the indicators is increased, and the planning and construction of the distribution network are better.</p>
<p>In order to further verify the rationality of the proposed comprehensive index system of distribution network, the present method is used as the control group, which does not contain the new power grid planning evaluation index constructed in this study. According to the calculation process of the analytic hierarchy process in <xref ref-type="sec" rid="s3-2">Section 3.2</xref>, the scores of comprehensive indicators of power grid planning by the present method are calculated, and the results are shown in <xref ref-type="table" rid="T6">Table 6</xref>.</p>
<table-wrap id="T6" position="float">
<label>TABLE 6</label>
<caption>
<p>Comprehensive score of power grid planning based on different index systems.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th rowspan="2" align="left"/>
<th colspan="2" align="left">Present method</th>
<th colspan="2" align="left">Proposed method</th>
</tr>
<tr>
<th align="left">Area M</th>
<th align="left">Area N</th>
<th align="left">Area M</th>
<th align="left">Area N</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">Comprehensive index score</td>
<td align="center">75.3392</td>
<td align="center">76.0261</td>
<td align="center">46.5296</td>
<td align="center">53.4703</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>According to <xref ref-type="table" rid="T6">Table 6</xref>, based on the present method, the comprehensive index scores of the two areas are 75.3392 and 76.0126, respectively. Since the adverse effects such as volatility and randomness caused by photovoltaics are not considered, the results obtained are higher than in this study. At the same time, the difference between the comprehensive scores of the two areas calculated based on the present method is 0.6869, and the difference between the comprehensive scores of the two areas calculated by the proposed method in this study is 6.9407. That is to say, the proposed comprehensive evaluation index system can describe the compensation effect of the energy storage, which provides an effective reference for the distribution network planning and construction. Therefore, the proposed method is more adaptable for the evaluation of the new distribution network with photovoltaic access.</p>
</sec>
</sec>
</sec>
<sec id="s6">
<title>6 Conclusion</title>
<p>Focus on the phenomenon of node voltage fluctuation and lines power flow fluctuation caused by distributed photovoltaic access, this study establishes a comprehensive evaluation system of distribution network considering distributed photovoltaic access, which mainly has the following innovations:<list list-type="simple">
<list-item>
<p>1) The Gaussian mixture model based on an improved particle swarm optimization algorithm can effectively describe the fluctuation and the correlation of active power output of photovoltaic power plants.</p>
</list-item>
<list-item>
<p>2) Considering the access characteristics of distributed generation, based on the linearized power flow equation, the joint probability density function of multi-node voltage and multi-line power flow can be obtained.</p>
</list-item>
<list-item>
<p>3) Based on the joint probability density function of multi-node voltage, the comprehensive evaluation index system of a distribution network for distributed photovoltaic accessing is defined. The distribution network evaluation system is improved, which can provide a theoretical reference for the planning, design, and optimal operation of a distribution network with a high proportion of new energy access in the future.</p>
</list-item>
</list>
</p>
</sec>
</body>
<back>
<sec sec-type="data-availability" id="s7">
<title>Data Availability Statement</title>
<p>The original contributions presented in the study are included in the article/Supplementary Material; further inquiries can be directed to the corresponding author.</p>
</sec>
<sec id="s8">
<title>Author Contributions</title>
<p>JX and YY each wrote a section of the manuscript. FW, JS, and FG contributed to data curation, analysis, and visualization. JX contributed to manuscript revision. All authors approved the submitted version.</p>
</sec>
<sec id="s9">
<title>Funding</title>
<p>The authors declare that this study received funding from Science and Technology Project of State Grid Shanghai Electric Power Company, grant number 520932200087. The funder had the following involvement in the study: Conceptualization, JX; methodology, JX; software, YY; validation, YY; formal analysis, FW; investigation, FW; resources, JS; data curation, YY; writing&#x2014;original draft preparation, JX; writing&#x2014;review and editing, JX; visualization, JX; supervision, JX; project administration, JS; funding acquisition, FG.</p>
</sec>
<sec sec-type="COI-statement" id="s10">
<title>Conflict of Interest</title>
<p>JX was employed by the State Grid Shanghai Electric Supply Company. YY, FW, JS, and FG were employed by the State Grid Shanghai Jinshan Electric Supply Company.</p>
</sec>
<sec sec-type="disclaimer" id="s11">
<title>Publisher&#x2019;s Note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors, and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ref-list>
<title>References</title>
<ref id="B1">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Angelim</surname>
<given-names>J. H.</given-names>
</name>
<name>
<surname>Affonso</surname>
<given-names>C. d. M.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Probabilistic Assessment of Voltage Quality on Solar-Powered Electric Vehicle Charging Station</article-title>. <source>Electr. Power Syst. Res.</source> <volume>189</volume>, <fpage>106655</fpage>. <pub-id pub-id-type="doi">10.1016/j.epsr.2020.106655</pub-id> </citation>
</ref>
<ref id="B2">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Chen</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Zheng</surname>
<given-names>H.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Robust UC Model Based on Multi&#x2010;band Uncertainty Set Considering the Temporal Correlation of Wind/load Prediction Errors</article-title>. <source>IET Gener. Transm. &#x26;amp; Distrib.</source> <volume>14</volume>, <fpage>180</fpage>&#x2013;<lpage>190</lpage>. <pub-id pub-id-type="doi">10.1049/iet-gtd.2019.1439</pub-id> </citation>
</ref>
<ref id="B3">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Dong</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Hou</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>Y.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Intelligent Decision-Making of Distribution Network Planning Scheme with Distributed Wind Power Generations</article-title>. <source>Int. J. Electr. Power &#x26; Energy Syst.</source> <volume>136</volume>, <fpage>107673</fpage>. <pub-id pub-id-type="doi">10.1016/j.ijepes.2021.107673</pub-id> </citation>
</ref>
<ref id="B4">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ferm&#xed;n</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Ainhoa</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Juan</surname>
<given-names>C.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Using Deep Learning and Meteorological Parameters to Forecast the Photovoltaic Generators Intra-hour Output Power Interval for Smart Grid Control</article-title>. <source>Energy</source> <volume>239</volume>, <fpage>122116</fpage>. <pub-id pub-id-type="doi">10.1016/j.energy.2021.122116</pub-id> </citation>
</ref>
<ref id="B5">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Guo</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Du</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Yang</surname>
<given-names>X.</given-names>
</name>
</person-group> (<year>2021</year>). <source>Research on Influence Factors and Evaluation Model of Distribution Network Green Index Based on Urban Energy Internet. 2021 China International Conference on Electricity Distribution</source>. <publisher-loc>Shanghai, China</publisher-loc>: <publisher-name>CICED</publisher-name>, <fpage>7</fpage>&#x2013;<lpage>9</lpage>. </citation>
</ref>
<ref id="B6">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Jia</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Gong</surname>
<given-names>X.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Short-term Photovoltaic Power Forecasting Based on VMD and ISSA-GRU</article-title>. <source>IEEE Access</source> <volume>9</volume>, <fpage>105939</fpage>&#x2013;<lpage>105950</lpage>. <pub-id pub-id-type="doi">10.1109/access.2021.3099169</pub-id> </citation>
</ref>
<ref id="B7">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Jiang</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Ji</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>Y.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>A Novel Gravitational Acceleration Enhanced Particle Swarm Optimization Algorithm for Wind-Thermal Economic Emission Dispatch Problem Considering Wind Power Availability</article-title>. <source>Int. J. Electr. Power &#x26; Energy Syst.</source> <volume>73</volume>, <fpage>1035</fpage>&#x2013;<lpage>1050</lpage>. <pub-id pub-id-type="doi">10.1016/j.ijepes.2015.06.014</pub-id> </citation>
</ref>
<ref id="B8">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Jin</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Shi</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Qian</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Yang</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Jin</surname>
<given-names>H.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Probabilistic Wind Power Forecasting Using Selective Ensemble of Finite Mixture Gaussian Process Regression Models</article-title>. <source>Renew. Energy</source> <volume>174</volume>, <fpage>1</fpage>&#x2013;<lpage>18</lpage>. <pub-id pub-id-type="doi">10.1016/j.renene.2021.04.028</pub-id> </citation>
</ref>
<ref id="B9">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Li</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Xu</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Zhao</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Wan</surname>
<given-names>C.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>A Coordinated Dispatch Model for Distribution Network Considering PV Ramp</article-title>. <source>IEEE Trans. Power Syst.</source> <volume>33</volume>, <fpage>1107</fpage>&#x2013;<lpage>1109</lpage>. <pub-id pub-id-type="doi">10.1109/tpwrs.2017.2735901</pub-id> </citation>
</ref>
<ref id="B10">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Liu</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>P. X.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>X.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Stochastic Small-Signal Stability Analysis of Grid-Connected Photovoltaic Systems</article-title>. <source>IEEE Trans. Ind. Electron.</source> <volume>63</volume>, <fpage>1027</fpage>&#x2013;<lpage>1038</lpage>. <pub-id pub-id-type="doi">10.1109/tie.2015.2481359</pub-id> </citation>
</ref>
<ref id="B11">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Meera</surname>
<given-names>P. S.</given-names>
</name>
<name>
<surname>Hemamalini</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Integrated Resource Planning for a Meshed Distribution Network under Uncertainty</article-title>. <source>Electr. Power Syst. Res.</source> <volume>195</volume>, <fpage>107127</fpage>. <pub-id pub-id-type="doi">10.1016/j.epsr.2021.107127</pub-id> </citation>
</ref>
<ref id="B12">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Murata</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Yamaguchi</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Otani</surname>
<given-names>K.</given-names>
</name>
</person-group> (<year>2009</year>). <article-title>A Method of Estimating the Output Fluctuation of Many Photovoltaic Power Generation Systems Dispersed in a Wide Area</article-title>. <source>Elect. Eng. Jpn.</source> <volume>166</volume>, <fpage>9</fpage>&#x2013;<lpage>19</lpage>. <pub-id pub-id-type="doi">10.1002/eej.20723</pub-id> </citation>
</ref>
<ref id="B13">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Noori</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Nouri</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Hajivand</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Multi-Objective Optimal Placement and Sizing of Distribution Static Compensator in Radial Distribution Networks with Variable Residential, Commercial and Industrial Demands Considering Reliability</article-title>. <source>IEEE Access</source> <volume>9</volume>, <fpage>46911</fpage>&#x2013;<lpage>46926</lpage>. <pub-id pub-id-type="doi">10.1109/access.2021.3065883</pub-id> </citation>
</ref>
<ref id="B14">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Peng</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Lin</surname>
<given-names>Q.</given-names>
</name>
<name>
<surname>Zhao</surname>
<given-names>W.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Research on Evaluation Index System and Scoring Method of Distribution Network Planning</article-title>. <source>Electr. Power Energy</source> <volume>38</volume>, <fpage>6</fpage>&#x2013;<lpage>12</lpage>. <pub-id pub-id-type="doi">10.19783/j.cnki.pspc.200803</pub-id> </citation>
</ref>
<ref id="B15">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rajabalizadeh</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Tafreshi</surname>
<given-names>S. M. M.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>A Practicable Copula-Based Approach for Power Forecasting of Small-Scale Photovoltaic Systems</article-title>. <source>IEEE Syst. J.</source> <volume>14</volume>, <fpage>4911</fpage>&#x2013;<lpage>4918</lpage>. <pub-id pub-id-type="doi">10.1109/jsyst.2019.2961661</pub-id> </citation>
</ref>
<ref id="B16">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Singh</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Pal</surname>
<given-names>B. C.</given-names>
</name>
<name>
<surname>Jabr</surname>
<given-names>R. A.</given-names>
</name>
</person-group> (<year>2010</year>). <article-title>Statistical Representation of Distribution System Loads Using Gaussian Mixture Model</article-title>. <source>IEEE Trans. Power Syst.</source> <volume>25</volume>, <fpage>29</fpage>&#x2013;<lpage>37</lpage>. <pub-id pub-id-type="doi">10.1109/tpwrs.2009.2030271</pub-id> </citation>
</ref>
<ref id="B17">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Song</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Pei</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Wei</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Yang</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Hu</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Review on Legislative System of Photovoltaic Industry Development in China</article-title>. <source>Energies</source> <volume>15</volume>, <fpage>306</fpage>. <pub-id pub-id-type="doi">10.3390/en15010306</pub-id> </citation>
</ref>
<ref id="B18">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Song</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Zhu</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>A Goal-reference-point Decision-Making Method Based on Normal Cloud Model and its Application in Distribution Network Planning Evaluation</article-title>. <source>Inf. Sci.</source> <volume>577</volume>, <fpage>883</fpage>&#x2013;<lpage>898</lpage>. <pub-id pub-id-type="doi">10.1016/j.ins.2021.08.064</pub-id> </citation>
</ref>
<ref id="B19">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Visser</surname>
<given-names>L. R.</given-names>
</name>
<name>
<surname>Schuurmans</surname>
<given-names>E. M. B.</given-names>
</name>
<name>
<surname>AlSkaif</surname>
<given-names>T. A.</given-names>
</name>
<name>
<surname>Fidder</surname>
<given-names>H. A.</given-names>
</name>
<name>
<surname>van Voorden</surname>
<given-names>A. M.</given-names>
</name>
<name>
<surname>van Sark</surname>
<given-names>W. G. J. H. M.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Regulation Strategies for Mitigating Voltage Fluctuations Induced by Photovoltaic Solar Systems in an Urban Low Voltage Grid</article-title>. <source>Int. J. Electr. Power &#x26; Energy Syst.</source> <volume>137</volume>, <fpage>107695</fpage>. <pub-id pub-id-type="doi">10.1016/j.ijepes.2021.107695</pub-id> </citation>
</ref>
<ref id="B20">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wang</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Sun</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Luo</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Peng</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Comparative Study of Machine Learning Approaches for Predicting Short-Term Photovoltaic Power Output Based on Weather Type Classification</article-title>. <source>Energy</source> <volume>240</volume>, <fpage>122733</fpage>. <pub-id pub-id-type="doi">10.1016/j.energy.2021.122733</pub-id> </citation>
</ref>
<ref id="B21">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wu</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Han</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Jiang</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Crow</surname>
<given-names>M. L.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>A Versatile Probability Model of Photovoltaic Generation Using Pair Copula Construction</article-title>. <source>IEEE Trans. Sustain. Energy</source> <volume>6</volume>, <fpage>1337</fpage>&#x2013;<lpage>1345</lpage>. <pub-id pub-id-type="doi">10.1109/tste.2015.2434934</pub-id> </citation>
</ref>
<ref id="B22">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Xiang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>Z.</given-names>
</name>
</person-group> (<year>2019</year>). <source>Improved Gaussian Mixture Model Based Probabilistic Power Flow of Wind Integrated Power System</source>. <publisher-loc>Atlanta</publisher-loc>: <publisher-name>IEEE Power &#x26; Energy Society General Meeting PESGM</publisher-name>. </citation>
</ref>
<ref id="B23">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Xiao</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>Y.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Negative Sequence Current and Reactive Power Comprehensive Compensation for Freight Railway Considering the Impact of DFIGs</article-title>. <source>Cpss Tpea</source> <volume>6</volume>, <fpage>235</fpage>&#x2013;<lpage>241</lpage>. <pub-id pub-id-type="doi">10.24295/cpsstpea.2021.00022</pub-id> </citation>
</ref>
<ref id="B24">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yang</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Xu</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Xu</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Han</surname>
<given-names>X.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Day-ahead Forecasting of Photovoltaic Output Power with Similar Cloud Space Fusion Based on Incomplete Historical Data Mining</article-title>. <source>Appl. Energy</source> <volume>206</volume>, <fpage>683</fpage>&#x2013;<lpage>696</lpage>. <pub-id pub-id-type="doi">10.1016/j.apenergy.2017.08.222</pub-id> </citation>
</ref>
<ref id="B25">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yu</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Benesty</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Huang</surname>
<given-names>G.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Daily Activity Feature Selection in Smart Homes Based on Pearson Correlation Coefficient</article-title>. <source>Int. J. Electr. Power &#x26; Energy Syst.</source> <volume>116</volume>. <pub-id pub-id-type="doi">10.1007/s11063-019-10185-8</pub-id> </citation>
</ref>
<ref id="B26">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zeng</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>Z.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Comprehensive Evaluation Method of Environmental Benefits of Smart Distribution Network Based on Balanced Principal Component Analysis</article-title>. <source>Power Syst. Technol.</source> <volume>40</volume>, <fpage>396</fpage>&#x2013;<lpage>404</lpage>. <pub-id pub-id-type="doi">10.13335/j.1000-3673.pst.2016.02.010</pub-id> </citation>
</ref>
<ref id="B27">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhang</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Pan</surname>
<given-names>L.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Policy Effect on Clean Coal-Fired Power Development in China</article-title>. <source>Energies</source> <volume>15</volume>, <fpage>897</fpage>. <pub-id pub-id-type="doi">10.3390/en15030897</pub-id> </citation>
</ref>
<ref id="B28">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Zhang</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Zhu</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Song</surname>
<given-names>R.</given-names>
</name>
</person-group> (<year>2021</year>). <source>A Mesh Analysis Model and the Coherent Evaluation Index System for Urban Distribution Network Planning. 2021 3rd Asia Energy and Electrical Engineering Symposium</source>. <publisher-loc>Chengdu, China</publisher-loc>: <publisher-name>AEEES</publisher-name>, <fpage>26</fpage>&#x2013;<lpage>29</lpage>. </citation>
</ref>
<ref id="B29">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhang</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Chiu</surname>
<given-names>Y.-B.</given-names>
</name>
<name>
<surname>Hsiao</surname>
<given-names>C. Y.-L.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Effects of Country Risks and Government Subsidies on Renewable Energy Firms&#x27; Performance: Evidence from China</article-title>. <source>Renew. Sustain. Energy Rev.</source> <volume>158</volume>, <fpage>112164</fpage>. <pub-id pub-id-type="doi">10.1016/j.rser.2022.112164</pub-id> </citation>
</ref>
<ref id="B30">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhang</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>W.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Two-stage Robust Security-Constrained Unit Commitment Model Considering Time Autocorrelation of Wind/load Prediction Error and Outage Contingency Probability of Units</article-title>. <source>IEEE ACCESS</source> <volume>7</volume>, <fpage>25398</fpage>&#x2013;<lpage>25408</lpage>. <pub-id pub-id-type="doi">10.1109/access.2019.2900254</pub-id> </citation>
</ref>
<ref id="B31">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhang</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Ma</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>W.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Two-stage Robust Security Constrained Unit Commitment Considering the Spatiotemporal Correlation of Uncertainty Prediction Error</article-title>. <source>IEEE ACCESS</source> <volume>7</volume>, <fpage>22891</fpage>&#x2013;<lpage>22901</lpage>. <pub-id pub-id-type="doi">10.1109/access.2019.2895625</pub-id> </citation>
</ref>
</ref-list>
</back>
</article>