<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="brief-report" dtd-version="2.3" xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Energy Res.</journal-id>
<journal-title>Frontiers in Energy Research</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Energy Res.</abbrev-journal-title>
<issn pub-type="epub">2296-598X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">759781</article-id>
<article-id pub-id-type="doi">10.3389/fenrg.2021.759781</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Energy Research</subject>
<subj-group>
<subject>Brief Research Report</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Quantifying Heat Transfer Characteristics of the Kroll Reactor in Titanium Sponge Production</article-title>
<alt-title alt-title-type="left-running-head">Wang and Wu</alt-title>
<alt-title alt-title-type="right-running-head">Heat Transfer of Kroll Reactor</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Wang</surname>
<given-names>Wenhao</given-names>
</name>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1386199/overview"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Wu</surname>
<given-names>Fuzhong</given-names>
</name>
</contrib>
</contrib-group>
<aff>School of Materials and Metallurgy, Guizhou University, <addr-line>Guiyang</addr-line>, <country>China</country>
</aff>
<author-notes>
<fn fn-type="edited-by">
<p>
<bold>Edited by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1261456/overview">Zongliang Zuo</ext-link>, Qingdao University of Technology, China</p>
</fn>
<fn fn-type="edited-by">
<p>
<bold>Reviewed by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1448382/overview">Kun Wang</ext-link>, Northeastern University, China</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1448547/overview">Zhen Yao</ext-link>, Guizhou Normal University, China</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1450935/overview">Mengqi Wei</ext-link>, Jiangsu Provincial Academy of Environmental Science, China</p>
</fn>
<corresp id="c001">&#x2a;Correspondence: Wenhao Wang, <email>whwang@gzu.edu.cn</email>
</corresp>
<fn fn-type="other">
<p>This article was submitted to Advanced Clean Fuel Technologies, a section of the journal Frontiers in Energy Research</p>
</fn>
</author-notes>
<pub-date pub-type="epub">
<day>30</day>
<month>09</month>
<year>2021</year>
</pub-date>
<pub-date pub-type="collection">
<year>2021</year>
</pub-date>
<volume>9</volume>
<elocation-id>759781</elocation-id>
<history>
<date date-type="received">
<day>17</day>
<month>08</month>
<year>2021</year>
</date>
<date date-type="accepted">
<day>16</day>
<month>09</month>
<year>2021</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2021 Wang and Wu.</copyright-statement>
<copyright-year>2021</copyright-year>
<copyright-holder>Wang and Wu</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these&#x20;terms.</p>
</license>
</permissions>
<abstract>
<p>Various reactors with different sizes have been widely used for the production of titanium sponge in the Kroll process. But the further commercialization of the forced heat transfer design of the Kroll reactor is limited by lack of standard parameter to evaluate its convective heat transfer characteristics. This work proposes to evaluate and compare the Kroll reactor with the dimensionless Nusselt number. The results shown that the heat transfer coefficients for both surfaces increase with the volume flow rate of cooling air for each dimensionless temperature, and the heat transfer coefficients of the external surface of the reactor are higher than that of the internal surface of the heater. And new correlations regarding the Nusselt number between the cooling air and the external surface of the reactor or the internal surface of the heater are obtained based on experimental data, while the characteristics of the cooling air, equipment and operation parameters are considered.</p>
</abstract>
<kwd-group>
<kwd>dimensionless temperature</kwd>
<kwd>heat transfer coefficient</kwd>
<kwd>nusselt number</kwd>
<kwd>convective heat transfer</kwd>
<kwd>titanium sponge</kwd>
</kwd-group>
</article-meta>
</front>
<body>
<sec id="s1">
<title>Introduction</title>
<p>The Kroll process is the most widely preferred industrial choice in titanium chain (<xref ref-type="bibr" rid="B6">Nakamura et&#x20;al., 2017</xref>; <xref ref-type="bibr" rid="B3">Gao et&#x20;al., 2018</xref>; <xref ref-type="bibr" rid="B7">Roux et&#x20;al., 2019</xref>), even if it was of archaic, costly and energy-intensive (<xref ref-type="bibr" rid="B14">Wang et&#x20;al., 2018b</xref>). Some of the major technological breakthroughs and equipment improvements in respect of titanium sponge production relating to the Kroll process have been achieved in the past decades (<xref ref-type="bibr" rid="B3">Gao et&#x20;al., 2018</xref>), and the production cost has been significantly brought down (<xref ref-type="bibr" rid="B15">Zhang et&#x20;al., 2016</xref>). However, further improvement is limited due to the insufficient theoretical understanding of the titanium sponge production (<xref ref-type="bibr" rid="B13">Wang et&#x20;al., 2018a</xref>; <xref ref-type="bibr" rid="B11">Wang W. et&#x20;al., 2020</xref>). For example, several efforts toward energy conservation were reported in the literature, but their commercial application is limited owning to technical or economic constraints (<xref ref-type="bibr" rid="B9">Wang and Wu, 2017</xref>). Currently, it&#x2019;s necessary to further decrease the energy consumption and improve energy efficiency of the Kroll process (<xref ref-type="bibr" rid="B4">Krauter et&#x20;al., 2018</xref>).</p>
<p>In response to the problems of the titanium sponge production discussed above, we had exploited a waste thermal energy recovery system with forced heat transfer design to enhance the surface heat dissipation of the Kroll reactor (<xref ref-type="fig" rid="F1">Figure&#x20;1A</xref>) (<xref ref-type="bibr" rid="B10">Wang et&#x20;al., 2017a</xref>), and to reduce the carbon emission. The result showed that there was a growth rate of about only 5.00% in the heat transfer rate in a vertical annular duct of the Kroll reactor, while the feeding rate of titanium tetrachloride increases significantly of about 9.61%. Therefore, the forced convective heat transfer system as currently designed was hence expected to reduce the electrical power consumption by improving the production efficiency (shorten the production cycle), rather than by recycling waste thermal energy in the subsequent recovery system (<xref ref-type="bibr" rid="B12">Wang et&#x20;al., 2017b</xref>). It is no doubt that the forced convective heat transfer design lowered the cost and improved the energy efficiency. However, the quantification and comparison of the heat transfer characteristics of the Kroll reactor with different sizes is difficult due to the lack of a standard method. For example, one previous work evaluated the heat transfer coefficient only based on the cooling air mass flow rate (<xref ref-type="bibr" rid="B10">Wang et&#x20;al., 2017a</xref>). The result could not be compared with other works which study the Kroll reactor with a different&#x20;size.</p>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption>
<p>System for: <bold>(A)</bold> enhancing heat transfer and recovering waste thermal energy for the Kroll equipment (<xref ref-type="bibr" rid="B12">Wang et&#x20;al., 2017b</xref>) and <bold>(B)</bold> the experimental apparatus and measurements.</p>
</caption>
<graphic xlink:href="fenrg-09-759781-g001.tif"/>
</fig>
<p>This works proposes a dimensionless Nusselt number as a general approach for quantifying and comparing the heat transfer characteristics of the vertical annular duct for the different Kroll reactor. And the Nusselt number has not been used for evaluating the heat transfer characteristics of the Kroll reactor in titanium sponge production. The establishment of this standard is expected to push the commercialization of the forced heat transfer design and optimizing the efficiency of the titanium sponge production process.</p>
</sec>
<sec id="s2">
<title>Experimental Apparatus and Procedure</title>
<p>The detailed structure of the Kroll equipment in titanium sponge production and the vertical annular duct named air-cooling zone had been depicted in our previously published works (<xref ref-type="bibr" rid="B10">Wang et&#x20;al., 2017a</xref>; <xref ref-type="bibr" rid="B12">Wang et&#x20;al., 2017b</xref>), and the reducer unit capacity is 12 tons per batch. Therefore, the apparatus and measurements are only represented briefly in the present experiment. The external diameter of the Kroll reactor is <italic>d</italic>
<sub>ext</sub> &#x3d; 2264&#xa0;mm and the internal diameter of the heater is <italic>d</italic>
<sub>int</sub> &#x3d; 2690&#xa0;mm that would surround a concentric vertical annular duct for the Kroll equipment, which is outlined in <xref ref-type="fig" rid="F1">Figure&#x20;1B</xref> with the present measurements. The thickness of the air-cooling zone is <italic>D</italic>
<sub>h</sub>/2 &#x3d; 213&#xa0;mm, and the length is <italic>l</italic>&#x20;&#x3d; 1192&#xa0;mm. There are nine groups of the inlet and the outlet for the cooling air (<xref ref-type="bibr" rid="B10">Wang et&#x20;al., 2017a</xref>). Both the roughness of the external surface and that of the internal surface are ignored.</p>
<p>The cooling air inlet temperatures, <italic>t</italic>
<sub>in</sub>, and outlet temperatures, <italic>t</italic>
<sub>out</sub>, are measured by standard thermocouples (type K, Class II) and collected by the analog I/O module (type ADAM-4018&#x2b;, 16-channel, 0&#x2013;1370.0&#xb0;C). The thermocouples for measuring cooling air inlet temperatures are numbered Row I and that for measuring cooling air outlet temperatures are numbered Row II. The accuracy of the analog I/O module is better than &#xb1;0.10% full-scale. The temperature of the TiCl<sub>4</sub>-Mg system in the Kroll reactor, <italic>t</italic>
<sub>c</sub>, is extracted from the DCS control system with an accuracy of &#xb1;2.0&#xb0;C. The volume flow rate of cooling air, <italic>q</italic>
<sub>V</sub>, is measured by a hot-wire anemometer (0.0056 to 0.1405&#xb0;m<sup>3</sup>/s, HHF-SD1) with an accuracy of &#xb1;1.00% full-scale stated by manufacturer. The measurements for the temperatures and the volume flow rate of cooling air are all installed near the center of the inlets or outlets. The external surface temperature of the reactor, <italic>t</italic>
<sub>ext</sub>, and internal surface temperature of the heater, <italic>t</italic>
<sub>int</sub>, are measured by a non-contact infrared thermometer (&#x2212;50&#x2013;1370&#xb0;C, DT-8869H) with an accuracy of &#xb1;1.50% full-scale.</p>
<p>The air inlet temperature and the air outlet temperature are the average value of nine measurements, respectively. The air volume flow rate is the sum value of nine measurements. All available experimental data for the natural and the forced convective heat transfer are listed in the <xref ref-type="sec" rid="s11">Supplementary Tables S1, S2</xref> in the Supplementary Material, respectively.</p>
</sec>
<sec id="s3">
<title>Technological Notes</title>
<p>To determine the heat transfer characteristics of the cooling air in both the natural convection and forced convection in the vertical annular duct of the Kroll equipment, the complex heat transfer coefficient and the Nusselt number that due to convection and radiation are analyzed. Experiments and measurements are conducted with stable production process. We firstly analyzed the convective heat transfer characteristics of the cooling air in the vertical annular duct of the Kroll equipment, and a new set of the heat transfer correlations were established by considering the characteristics of cooling air, equipment and operation parameters. In the vertical annular duct, the cooling air absorbs thermal energy from the external surface of the reactor and the internal surface of the heater by convective and radiant heat transfer,<disp-formula id="e1">
<mml:math id="m1">
<mml:mrow>
<mml:mi>Q</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mi>Q</mml:mi>
<mml:mrow>
<mml:mi>int</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2b;</mml:mo>
<mml:msub>
<mml:mi>Q</mml:mi>
<mml:mrow>
<mml:mtext>ext</mml:mtext>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
<label>(1)</label>
</disp-formula>
<disp-formula id="e2a">
<mml:math id="m2">
<mml:mrow>
<mml:msub>
<mml:mi>Q</mml:mi>
<mml:mrow>
<mml:mi>int</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mi>h</mml:mi>
<mml:mrow>
<mml:mtext>int</mml:mtext>
</mml:mrow>
</mml:msub>
<mml:msub>
<mml:mi>A</mml:mi>
<mml:mrow>
<mml:mtext>int</mml:mtext>
</mml:mrow>
</mml:msub>
<mml:mi>&#x394;</mml:mi>
<mml:msub>
<mml:mi>t</mml:mi>
<mml:mrow>
<mml:mi>int</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mi>&#x3c0;</mml:mi>
<mml:mi>l</mml:mi>
<mml:msub>
<mml:mi>d</mml:mi>
<mml:mrow>
<mml:mi>int</mml:mi>
</mml:mrow>
</mml:msub>
<mml:msub>
<mml:mi>h</mml:mi>
<mml:mrow>
<mml:mtext>int</mml:mtext>
</mml:mrow>
</mml:msub>
<mml:mi>&#x394;</mml:mi>
<mml:msub>
<mml:mi>t</mml:mi>
<mml:mrow>
<mml:mi>int</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
<label>(2a)</label>
</disp-formula>
<disp-formula id="e2b">
<mml:math id="m3">
<mml:mrow>
<mml:msub>
<mml:mi>Q</mml:mi>
<mml:mrow>
<mml:mtext>ext</mml:mtext>
</mml:mrow>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:msub>
<mml:mi>h</mml:mi>
<mml:mrow>
<mml:mtext>ext</mml:mtext>
</mml:mrow>
</mml:msub>
<mml:msub>
<mml:mi>A</mml:mi>
<mml:mrow>
<mml:mtext>ext</mml:mtext>
</mml:mrow>
</mml:msub>
<mml:mi>&#x394;</mml:mi>
<mml:msub>
<mml:mi>t</mml:mi>
<mml:mrow>
<mml:mtext>ext</mml:mtext>
</mml:mrow>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mi>&#x3c0;</mml:mi>
<mml:mi>l</mml:mi>
<mml:msub>
<mml:mi>d</mml:mi>
<mml:mrow>
<mml:mtext>ext</mml:mtext>
</mml:mrow>
</mml:msub>
<mml:msub>
<mml:mi>h</mml:mi>
<mml:mrow>
<mml:mtext>ext</mml:mtext>
</mml:mrow>
</mml:msub>
<mml:mi>&#x394;</mml:mi>
<mml:msub>
<mml:mi>t</mml:mi>
<mml:mrow>
<mml:mtext>ext</mml:mtext>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
<label>(2b)</label>
</disp-formula>Where <italic>Q</italic> is the heat transfer rate due to convection and radiation, <italic>h</italic> is the complex heat transfer coefficient, <italic>A</italic> is the heat transfer area, &#x394;<italic>t</italic> is the logarithmic temperature difference (<xref ref-type="bibr" rid="B10">Wang et&#x20;al., 2017a</xref>), and <italic>d</italic> is the internal diameter of the heater or the external diameter of the reactor. The subscripts, int and ext, represent the internal surface of the heater and the external surface of the reactor, respectively. The enthalpy energy change of cooling air is calculated by:<disp-formula id="e3">
<mml:math id="m4">
<mml:mrow>
<mml:mi>Q</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mstyle displaystyle="true">
<mml:mrow>
<mml:munderover>
<mml:mo>&#x222b;</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi>t</mml:mi>
<mml:mrow>
<mml:mtext>in</mml:mtext>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mrow>
<mml:msub>
<mml:mi>t</mml:mi>
<mml:mrow>
<mml:mtext>out</mml:mtext>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:munderover>
<mml:mrow>
<mml:mi>&#x3c1;</mml:mi>
<mml:msub>
<mml:mi>c</mml:mi>
<mml:mi>p</mml:mi>
</mml:msub>
<mml:msub>
<mml:mi>q</mml:mi>
<mml:mtext>V</mml:mtext>
</mml:msub>
<mml:mi>d</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:mrow>
</mml:mstyle>
</mml:mrow>
</mml:math>
<label>(3)</label>
</disp-formula>Where <italic>t</italic>
<sub>in</sub> and <italic>t</italic>
<sub>out</sub> are the inlet and the outlet temperatures of cooling air, <italic>q</italic>
<sub>V</sub> is the volume flow rate, <italic>&#x3c1;</italic> and <italic>c</italic>
<sub>
<italic>p</italic>
</sub> are the density and the specific heat capacity of cooling air, respectively. Then, the Nusselt number is expressed as (<xref ref-type="bibr" rid="B5">Liu et&#x20;al., 2019</xref>; <xref ref-type="bibr" rid="B8">Wang B. et&#x20;al., 2020</xref>):<disp-formula id="e4">
<mml:math id="m5">
<mml:mrow>
<mml:mi>N</mml:mi>
<mml:mi>u</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mi>h</mml:mi>
<mml:msub>
<mml:mi>D</mml:mi>
<mml:mtext>h</mml:mtext>
</mml:msub>
</mml:mrow>
<mml:mi>&#x3bb;</mml:mi>
</mml:mfrac>
</mml:mrow>
</mml:math>
<label>(4)</label>
</disp-formula>Where <italic>D</italic>
<sub>h</sub> is the characteristic length and <italic>&#x3bb;</italic> is the thermal conductivity of cooling air. It could be expected that the Nusselt number is the function of the Rayleigh number for natural convective heat transfer or the function of the Reynolds number and the Prandtl number for forced convective heat transfer, while the physical and the geometrical characteristics would be summarized into dimensionless parameters as follows (<xref ref-type="bibr" rid="B8">Wang B. et&#x20;al., 2020</xref>):<disp-formula id="e5">
<mml:math id="m6">
<mml:mrow>
<mml:mi>N</mml:mi>
<mml:mi>u</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mi>f</mml:mi>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mi>R</mml:mi>
<mml:mi>a</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>C</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mi>for</mml:mi>
<mml:mtext>&#x2009;</mml:mtext>
<mml:mtext>natural</mml:mtext>
<mml:mtext>convection</mml:mtext>
</mml:mrow>
</mml:math>
<label>(5)</label>
</disp-formula>
<disp-formula id="e6">
<mml:math id="m7">
<mml:mrow>
<mml:mi>N</mml:mi>
<mml:mi>u</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mi>g</mml:mi>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:mi>R</mml:mi>
<mml:mi>e</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>P</mml:mi>
<mml:mi>r</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>C</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
<mml:mi>for</mml:mi>
<mml:mtext>&#x2009;</mml:mtext>
<mml:mtext>forced</mml:mtext>
<mml:mtext>convection</mml:mtext>
</mml:mrow>
</mml:math>
<label>(6)</label>
</disp-formula>Where <italic>Ra</italic> is the Rayleigh number, <italic>Re</italic> is the Reynolds number, <italic>Pr</italic> is the Prandtl number, and <italic>Ct</italic> is the dimensionless temperature. These dimensionless parameters are defined as (<xref ref-type="bibr" rid="B2">Cheng et&#x20;al., 2019</xref>; <xref ref-type="bibr" rid="B1">Chai et&#x20;al., 2020</xref>):<disp-formula id="e7">
<mml:math id="m8">
<mml:mrow>
<mml:mi>R</mml:mi>
<mml:mi>a</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:msup>
<mml:mi>&#x3c1;</mml:mi>
<mml:mn>2</mml:mn>
</mml:msup>
<mml:msub>
<mml:mi>c</mml:mi>
<mml:mi>p</mml:mi>
</mml:msub>
<mml:mi>g</mml:mi>
<mml:mi>&#x394;</mml:mi>
<mml:mi>t</mml:mi>
<mml:msubsup>
<mml:mi>D</mml:mi>
<mml:mtext>h</mml:mtext>
<mml:mn>3</mml:mn>
</mml:msubsup>
</mml:mrow>
<mml:mrow>
<mml:mi>&#x3bb;</mml:mi>
<mml:mi>&#x3bc;</mml:mi>
<mml:msub>
<mml:mi>T</mml:mi>
<mml:mtext>s</mml:mtext>
</mml:msub>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:math>
<label>(7)</label>
</disp-formula>
<disp-formula id="e8">
<mml:math id="m9">
<mml:mrow>
<mml:mi>P</mml:mi>
<mml:mi>r</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mi>&#x3bc;</mml:mi>
<mml:msub>
<mml:mi>c</mml:mi>
<mml:mi>p</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mi>&#x3bb;</mml:mi>
</mml:mfrac>
</mml:mrow>
</mml:math>
<label>(8)</label>
</disp-formula>
<disp-formula id="e9">
<mml:math id="m10">
<mml:mrow>
<mml:mi>R</mml:mi>
<mml:mi>e</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mn>4</mml:mn>
<mml:mi>&#x3c1;</mml:mi>
<mml:msub>
<mml:mi>q</mml:mi>
<mml:mtext>V</mml:mtext>
</mml:msub>
</mml:mrow>
<mml:mrow>
<mml:mi>&#x3c0;</mml:mi>
<mml:mi>&#x3bc;</mml:mi>
<mml:mrow>
<mml:mo>(</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi>d</mml:mi>
<mml:mrow>
<mml:mtext>ext</mml:mtext>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2b;</mml:mo>
<mml:msub>
<mml:mi>d</mml:mi>
<mml:mrow>
<mml:mtext>int</mml:mtext>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mo>)</mml:mo>
</mml:mrow>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:math>
<label>(9)</label>
</disp-formula>
<disp-formula id="e10">
<mml:math id="m11">
<mml:mrow>
<mml:mi>C</mml:mi>
<mml:mi>t</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:msub>
<mml:mi>t</mml:mi>
<mml:mtext>c</mml:mtext>
</mml:msub>
<mml:mo>&#x2b;</mml:mo>
<mml:mn>273</mml:mn>
<mml:mtext>.</mml:mtext>
<mml:mn>15</mml:mn>
</mml:mrow>
<mml:mrow>
<mml:msub>
<mml:mi>t</mml:mi>
<mml:mrow>
<mml:mtext>out</mml:mtext>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2b;</mml:mo>
<mml:mn>273</mml:mn>
<mml:mtext>.</mml:mtext>
<mml:mn>15</mml:mn>
</mml:mrow>
</mml:mfrac>
<mml:mo>&#x2212;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
</mml:math>
<label>(10)</label>
</disp-formula>Where <italic>g</italic> is the gravitational acceleration, <italic>&#x3bc;</italic> is the viscosity of cooling air, <italic>T</italic>
<sub>s</sub> is the temperature of the heat transfer surface in the Kelvin&#x20;scale.</p>
</sec>
<sec id="s4">
<title>Results and Disscussions</title>
<p>The complex heat transfer coefficients of the natural convection and the forced convection for both heat transfer surfaces are illustrated in <xref ref-type="fig" rid="F2">Figure&#x20;2</xref>, respectively. Measurements and calculations reveal that the heat transfer coefficients increase linearly with the volume flow rate of the cooling air for each dimensionless temperature. In the case of natural convective heat transfer, as shown in <xref ref-type="fig" rid="F2">Figures 2A,B</xref>, higher temperature differences between the cooling air and heat transfer surfaces would lead to a higher volume flow rate of cooling air and higher heat transfer rate. It would be observed that a higher volume flow rate of the cooling air is correlated with a greater heat transfer rate. Besides, the Rayleigh numbers have a positive correlation with the Nusselt numbers for both heat transfer surfaces, as shown in <xref ref-type="fig" rid="F3">Figure&#x20;3</xref>. And the Nusselt number increased obviously with the Rayleigh number. Hence, it is possible to improve the heat transfer performance of the air-cooling zone by using a forced convection scheme. For natural convective heat transfer (<xref ref-type="fig" rid="F2">Figures 2A,B</xref>), it is clear that the heat transfer coefficient of the external surface of the reactor is about 3.50&#x20;times that of the internal surface of the heater for each dimensionless temperature. Hence, the heat transfer rate of the external surface of the reactor maybe close to 80.00% of the total heat transfer rate. That is, the performance of the vertical annular air-cooling zone of the Kroll equipment is mainly determined by heat transfer between the cooling air and the external surface of the reactor in the case of natural convection.</p>
<fig id="F2" position="float">
<label>FIGURE 2</label>
<caption>
<p>Complex mean heat transfer coefficients of the natural convection and the forced convection.</p>
</caption>
<graphic xlink:href="fenrg-09-759781-g002.tif"/>
</fig>
<fig id="F3" position="float">
<label>FIGURE 3</label>
<caption>
<p>Relationship between Nusselt number and relative dimensionless parameters of the natural convection.</p>
</caption>
<graphic xlink:href="fenrg-09-759781-g003.tif"/>
</fig>
<p>Besides the air volume flow rate, a higher dimensionless temperature <italic>Ct</italic> results in a greater heat transfer coefficient for the natural convection, as shown in <xref ref-type="fig" rid="F2">Figures 2A,B</xref>. It is understandable that the natural convection in the vertical annular air-cooling zone is driven by the temperature difference between the cooling air and the TiCl<sub>4</sub>-Mg system in the Kroll reactor. Thus, the Nusselt number also increases with the dimensionless temperature, as shown in <xref ref-type="fig" rid="F3">Figure&#x20;3</xref>. The Rayleigh number and the dimensionless temperature show important effects on the heat transfer in the natural convection case. Thus, the physical and the geometrical characteristics could be summarized into dimensionless parameters as follows:</p>
<p>The external surface of the reactor:<disp-formula id="e11a">
<mml:math id="m12">
<mml:mrow>
<mml:mi>N</mml:mi>
<mml:msub>
<mml:mi>u</mml:mi>
<mml:mrow>
<mml:mtext>ext</mml:mtext>
</mml:mrow>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mtext>0</mml:mtext>
<mml:mtext>.</mml:mtext>
<mml:mn>333</mml:mn>
<mml:mi>R</mml:mi>
<mml:msubsup>
<mml:mi>a</mml:mi>
<mml:mrow>
<mml:mtext>ext</mml:mtext>
</mml:mrow>
<mml:mrow>
<mml:mtext>0</mml:mtext>
<mml:mrow>
<mml:mtext>.</mml:mtext>
<mml:mn>320</mml:mn>
</mml:mrow>
</mml:mrow>
</mml:msubsup>
<mml:mi>C</mml:mi>
<mml:msup>
<mml:mi>t</mml:mi>
<mml:mrow>
<mml:mtext>0</mml:mtext>
<mml:mrow>
<mml:mtext>.</mml:mtext>
<mml:mn>488</mml:mn>
</mml:mrow>
</mml:mrow>
</mml:msup>
<mml:mo>,</mml:mo>
<mml:msup>
<mml:mi>R</mml:mi>
<mml:mn>2</mml:mn>
</mml:msup>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0.994</mml:mn>
</mml:mrow>
</mml:math>
<label>(11a)</label>
</disp-formula>
</p>
<p>The internal surface of the heater:<disp-formula id="e11b">
<mml:math id="m13">
<mml:mrow>
<mml:mi>N</mml:mi>
<mml:msub>
<mml:mi>u</mml:mi>
<mml:mrow>
<mml:mi>int</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mtext>0</mml:mtext>
<mml:mtext>.</mml:mtext>
<mml:mn>411</mml:mn>
<mml:mi>R</mml:mi>
<mml:msubsup>
<mml:mi>a</mml:mi>
<mml:mrow>
<mml:mi>int</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mtext>0</mml:mtext>
<mml:mrow>
<mml:mtext>.</mml:mtext>
<mml:mn>245</mml:mn>
</mml:mrow>
</mml:mrow>
</mml:msubsup>
<mml:mi>C</mml:mi>
<mml:msup>
<mml:mi>t</mml:mi>
<mml:mrow>
<mml:mtext>0</mml:mtext>
<mml:mrow>
<mml:mtext>.</mml:mtext>
<mml:mn>488</mml:mn>
</mml:mrow>
</mml:mrow>
</mml:msup>
<mml:mo>,</mml:mo>
<mml:msup>
<mml:mi>R</mml:mi>
<mml:mn>2</mml:mn>
</mml:msup>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0.993</mml:mn>
</mml:mrow>
</mml:math>
<label>(11b)</label>
</disp-formula>
</p>
<p>The <xref ref-type="disp-formula" rid="e11a">Eq. 11</xref> could be used as the criteria for evaluating the performance of the natural convection in the vertical annular air-cooling zone of the Kroll equipment for titanium sponge production. The parameters used include the characteristics of the cooling air, equipment and operation parameters.</p>
<p>In the case of forced convective heat transfer, as shown in <xref ref-type="fig" rid="F2">Figures 2C,D</xref>, the complex heat transfer coefficients for both the external and internal surfaces are investigated. Note that the heat transfer coefficients increase linearly with volume flow rate of the cooling air for all dimensionless temperatures. It would be observed that a higher volume flow rate of the cooling air results in a greater heat transfer rate during forced convection. Thus, the Nusselt numbers for both heat transfer surfaces increase obviously with the Reynolds number, as shown in <xref ref-type="fig" rid="F4">Figure&#x20;4</xref>.</p>
<fig id="F4" position="float">
<label>FIGURE 4</label>
<caption>
<p>Relationship between Nusselt number and relative dimensionless parameters of the forced convection.</p>
</caption>
<graphic xlink:href="fenrg-09-759781-g004.tif"/>
</fig>
<p>However, the heat transfer coefficient of the external surface of the reactor is only about 3.00&#x20;times that of the internal surface of the heater for all dimensionless temperatures. The heat transfer rate of the external surface of the reactor accounts for about 76.00% of the total heat transfer rate. That is, the performance of the vertical annular air-cooling zone of the Kroll equipment is still mainly determined by the heat transfer between the cooling air and the external surface of the reactor in the case of forced convection.</p>
<p>The purpose of the forced convection in the vertical annular duct of the Kroll equipment is to enhance the heat transfer of the TiCl<sub>4</sub>-Mg system. The heat transfer coefficients for both heat transfer surfaces are nearly independent with the dimensionless temperature, and so do the Nusselt numbers. Thus, the physical and the geometrical characteristics would be summarized into dimensionless parameters as follows:</p>
<p>The external surface of the reactor:<disp-formula id="e12a">
<mml:math id="m14">
<mml:mrow>
<mml:mi>N</mml:mi>
<mml:msub>
<mml:mi>u</mml:mi>
<mml:mrow>
<mml:mtext>ext</mml:mtext>
</mml:mrow>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mtext>0</mml:mtext>
<mml:mtext>.</mml:mtext>
<mml:mn>157</mml:mn>
<mml:mi>R</mml:mi>
<mml:msup>
<mml:mi>e</mml:mi>
<mml:mrow>
<mml:mn>0.921</mml:mn>
</mml:mrow>
</mml:msup>
<mml:mi>C</mml:mi>
<mml:msup>
<mml:mi>t</mml:mi>
<mml:mrow>
<mml:mtext>0</mml:mtext>
<mml:mrow>
<mml:mtext>.</mml:mtext>
<mml:mn>104</mml:mn>
</mml:mrow>
</mml:mrow>
</mml:msup>
<mml:mo>,</mml:mo>
<mml:msup>
<mml:mi>R</mml:mi>
<mml:mn>2</mml:mn>
</mml:msup>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0.997</mml:mn>
</mml:mrow>
</mml:math>
<label>(12a)</label>
</disp-formula>
</p>
<p>The internal surface of the heater:<disp-formula id="e12b">
<mml:math id="m15">
<mml:mrow>
<mml:mi>N</mml:mi>
<mml:msub>
<mml:mi>u</mml:mi>
<mml:mrow>
<mml:mi>int</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mtext>0</mml:mtext>
<mml:mtext>.</mml:mtext>
<mml:mn>144</mml:mn>
<mml:mi>R</mml:mi>
<mml:msup>
<mml:mi>e</mml:mi>
<mml:mrow>
<mml:mtext>0</mml:mtext>
<mml:mrow>
<mml:mtext>.</mml:mtext>
<mml:mn>786</mml:mn>
</mml:mrow>
</mml:mrow>
</mml:msup>
<mml:mi>C</mml:mi>
<mml:msup>
<mml:mi>t</mml:mi>
<mml:mrow>
<mml:mtext>0</mml:mtext>
<mml:mrow>
<mml:mtext>.</mml:mtext>
<mml:mn>077</mml:mn>
</mml:mrow>
</mml:mrow>
</mml:msup>
<mml:mo>,</mml:mo>
<mml:msup>
<mml:mi>R</mml:mi>
<mml:mn>2</mml:mn>
</mml:msup>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>0.996</mml:mn>
</mml:mrow>
</mml:math>
<label>(12b)</label>
</disp-formula>
</p>
<p>The <xref ref-type="disp-formula" rid="e12a">Eq. 12</xref> could be a design criterion of the forced convection in the vertical annular air-cooling zone of the Kroll equipment for titanium sponge production, while the characteristics of the cooling air, equipment and operation parameters are considered.</p>
</sec>
<sec sec-type="conclusion" id="s5">
<title>Conclusion</title>
<p>In summary for quantifying the heat transfer characteristics for the Kroll equipment used in titanium sponge production, this work proposes to calculate the Nusselt numbers based on parameters including the cooling air, equipment and operation. and the heat transfer coefficients for both the external surface of the reactor and the internal surface of the heater are also investigated. The main findings of this study can be listed as follows:<list list-type="simple">
<list-item>
<p>1) The heat transfer coefficients for both surfaces increase with the volume flow rate of cooling air for each dimensionless temperature.</p>
</list-item>
<list-item>
<p>2) The heat transfer coefficients of the external surface of the reactor are higher than that of the internal surface of the heater.</p>
</list-item>
<list-item>
<p>3) The dimensionless temperature has an important effect on the Nusselt number in the natural convective heat transfer, except for the forced convection.</p>
</list-item>
<list-item>
<p>4) New correlations regarding the Nusselt number between the cooling air and the external surface of the reactor or the internal surface of the heater are obtained based on experimental data, while the characteristics of the cooling air, equipment and operation parameters are considered.</p>
</list-item>
</list>
</p>
</sec>
</body>
<back>
<sec id="s6">
<title>Data Availability Statement</title>
<p>The original contributions presented in the study are included in the article/<xref ref-type="sec" rid="s11">Supplementary Material</xref>, further inquiries can be directed to the corresponding authors.</p>
</sec>
<sec id="s7">
<title>Author Contributions</title>
<p>WW: conceptualization; data curation; formal analysis; methodology; writing-original draft; project administration. FW: supervision; writing-review and editing.</p>
</sec>
<sec id="s8">
<title>Funding</title>
<p>The authors acknowledge the financial support received from the Science and Technology Foundation of Guizhou Province (grant number QKHJC-ZK 2021-YB261), the National Natural Science Foundation of China (grant number 51874108), and the Talent Projects of Guizhou University and the Education Department of Guizhou Province (grant number GDPY 2019-20, GDRJHZ 2019-14, and QJHKYZ 2021-097).</p>
</sec>
<sec sec-type="COI-statement" id="s9">
<title>Conflict of Interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec sec-type="disclaimer" id="s10">
<title>Publisher&#x2019;s Note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ack>
<p>The authors are grateful to Qiang Liang and Lvguo Zhang of Zunyi Titanium Co., Ltd. for their valuable discussions and experimental batches supply throughout this work. One of the authors, WW, is grateful to Professor Xiang Ge of Guizhou University for his valuable advice. And all co-authors thank the reviewers for the valuable comments and suggestions.</p>
</ack>
<sec id="s11">
<title>Supplementary Material</title>
<p>The Supplementary Material for this article can be found online at: <ext-link ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/fenrg.2021.759781/full#supplementary-material">https://www.frontiersin.org/articles/10.3389/fenrg.2021.759781/full&#x23;supplementary-material</ext-link>
</p>
<supplementary-material xlink:href="DataSheet1.docx" id="SM1" mimetype="application/docx" xmlns:xlink="http://www.w3.org/1999/xlink"/>
</sec>
<ref-list>
<title>References</title>
<ref id="B1">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Chai</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Xiong</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Cheng</surname>
<given-names>X.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Numerical Investigation of Turbulent Heat Transfer Properties at Low Prandtl Number</article-title>. <source>Front. Energ. Res.</source> <volume>8</volume>, <fpage>112</fpage>. <pub-id pub-id-type="doi">10.3389/fenrg.2020.00112</pub-id> </citation>
</ref>
<ref id="B2">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cheng</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Yanlin</surname>
<given-names>A. B.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Zhao</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Diameter Effect on the Wall Temperature Behaviors During Supercritical Water Heat Transfer Deterioration in Circular Tubes and Annular Channels</article-title>. <source>Front. Energ. Res.</source> <volume>7</volume>, <fpage>73</fpage>. <pub-id pub-id-type="doi">10.3389/fenrg.2019.00073</pub-id> </citation>
</ref>
<ref id="B3">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gao</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Nie</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Yang</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Sun</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Gong</surname>
<given-names>X.</given-names>
</name>
<etal/>
</person-group> (<year>2018</year>). <article-title>Environmental Impacts Analysis of Titanium Sponge Production Using Kroll Process in China</article-title>. <source>J.&#x20;Clean. Prod.</source> <volume>174</volume>, <fpage>771</fpage>&#x2013;<lpage>779</lpage>. <pub-id pub-id-type="doi">10.1016/j.jclepro.2017.09.240</pub-id> </citation>
</ref>
<ref id="B4">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Krauter</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Eckert</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Gundrum</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Stefani</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Wondrak</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Frick</surname>
<given-names>P.</given-names>
</name>
<etal/>
</person-group> (<year>2018</year>). <article-title>Inductive System for Reliable Magnesium Level Detection in a Titanium Reduction Reactor</article-title>. <source>Metall. Materi Trans. B.</source> <volume>49</volume> (<issue>4</issue>), <fpage>2089</fpage>&#x2013;<lpage>2096</lpage>. <pub-id pub-id-type="doi">10.1007/s11663-018-1291-y</pub-id> </citation>
</ref>
<ref id="B5">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Liu</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Yue</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>She</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Fan</surname>
<given-names>G.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Numerical Analysis of Turbulent Flow and Heat Transfer in Internally Finned Tubes</article-title>. <source>Front. Energ. Res.</source> <volume>7</volume>, <fpage>64</fpage>. <pub-id pub-id-type="doi">10.3389/fenrg.2019.00064</pub-id> </citation>
</ref>
<ref id="B6">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Nakamura</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Iida</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Nakamura</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Araike</surname>
<given-names>T.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Titanium Sponge Production Method by Kroll Process at OTC</article-title>. <source>Mater. Trans.</source> <volume>58</volume> (<issue>3</issue>), <fpage>319</fpage>&#x2013;<lpage>321</lpage>. <pub-id pub-id-type="doi">10.2320/matertrans.MK201634</pub-id> </citation>
</ref>
<ref id="B7">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Roux</surname>
<given-names>R. N.</given-names>
</name>
<name>
<surname>Van der Lingen</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Botha</surname>
<given-names>A. P.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>A Systematic Literature Review on the Titanium Metal Product Value Chain</article-title>. <source>Sajie</source> <volume>30</volume> (<issue>3</issue>), <fpage>115</fpage>&#x2013;<lpage>133</lpage>. <pub-id pub-id-type="doi">10.7166/30-3-2233</pub-id> </citation>
</ref>
<ref id="B8">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wang</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Ke</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Wen</surname>
<given-names>J.</given-names>
</name>
<etal/>
</person-group> (<year>2020a</year>). <article-title>Analysis of the Flow Characteristics of the Liquid Film on the Wall Surface of the Corrugated Plate Dryer Based on PSD Method: A Short Communication</article-title>. <source>Front. Energ. Res.</source> <volume>8</volume>, <fpage>215</fpage>. <pub-id pub-id-type="doi">10.3389/fenrg.2020.00215</pub-id> </citation>
</ref>
<ref id="B9">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wang</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Wu</surname>
<given-names>F.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Exergy Destruction Analysis of Heat Exchanger in Waste Heat Recovery System in Kroll Process</article-title>. <source>Ijex</source> <volume>22</volume> (<issue>1</issue>), <fpage>89</fpage>&#x2013;<lpage>101</lpage>. <pub-id pub-id-type="doi">10.1504/IJEX.2017.10001122</pub-id> </citation>
</ref>
<ref id="B10">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wang</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Wu</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Jin</surname>
<given-names>H.</given-names>
</name>
</person-group> (<year>2017a</year>). <article-title>Enhancement and Performance Evaluation for Heat Transfer of Air Cooling Zone for Reduction System of Sponge Titanium</article-title>. <source>Heat Mass. Transfer</source> <volume>53</volume> (<issue>2</issue>), <fpage>465</fpage>&#x2013;<lpage>473</lpage>. <pub-id pub-id-type="doi">10.1007/s00231-016-1836-z</pub-id> </citation>
</ref>
<ref id="B11">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wang</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Wu</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Jin</surname>
<given-names>H.</given-names>
</name>
</person-group> (<year>2020b</year>). <article-title>Gaseous P-V-T Property Measurements for Titanium Tetrachloride from 873.0 to 1173.0&#x20;K and Low Pressure of 34.05&#x20;kPa</article-title>. <source>ACS Omega</source> <volume>5</volume> (<issue>30</issue>), <fpage>18573</fpage>&#x2013;<lpage>18578</lpage>. <pub-id pub-id-type="doi">10.1021/acsomega.0c00667</pub-id> </citation>
</ref>
<ref id="B12">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wang</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Wu</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Yu</surname>
<given-names>Q.</given-names>
</name>
</person-group> (<year>2017b</year>). <article-title>Feasibility Study for Recovering Waste Heat in Reduction System of Kroll Process: Energy Analysis and Economic Valuation</article-title>. <source>Russ. J.&#x20;Non-ferrous Met.</source> <volume>58</volume> (<issue>3</issue>), <fpage>258</fpage>&#x2013;<lpage>268</lpage>. <pub-id pub-id-type="doi">10.3103/S1067821217030208</pub-id> </citation>
</ref>
<ref id="B13">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wang</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Wu</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Yu</surname>
<given-names>Q.</given-names>
</name>
<name>
<surname>Jin</surname>
<given-names>H.</given-names>
</name>
</person-group> (<year>2018a</year>). <article-title>Experimental Investigation of Titanium Tetrachloride in Pool Boiling Heat Transfer</article-title>. <source>Int. J.&#x20;Heat Mass Transfer</source> <volume>122</volume>, <fpage>1308</fpage>&#x2013;<lpage>1312</lpage>. <pub-id pub-id-type="doi">10.1016/j.ijheatmasstransfer.2018.02.051</pub-id> </citation>
</ref>
<ref id="B14">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wang</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Wu</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Yu</surname>
<given-names>Q.</given-names>
</name>
<name>
<surname>Jin</surname>
<given-names>H.</given-names>
</name>
</person-group> (<year>2018b</year>). <article-title>Interfacial Liquid-Vapor Phase Change and Entropy Generation in Pool Boiling Experiment for Titanium Tetrachloride</article-title>. <source>J.&#x20;Therm. Anal. Calorim.</source> <volume>133</volume> (<issue>3</issue>), <fpage>1571</fpage>&#x2013;<lpage>1578</lpage>. <pub-id pub-id-type="doi">10.1007/s10973-018-7203-1</pub-id> </citation>
</ref>
<ref id="B15">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Fang</surname>
<given-names>Z. Z.</given-names>
</name>
<name>
<surname>Xia</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Huang</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Lefler</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>T.</given-names>
</name>
<etal/>
</person-group> (<year>2016</year>). <article-title>A Novel Chemical Pathway for Energy Efficient Production of Ti Metal from Upgraded Titanium Slag</article-title>. <source>Chem. Eng. J.</source> <volume>286</volume>, <fpage>517</fpage>&#x2013;<lpage>527</lpage>. <pub-id pub-id-type="doi">10.1016/j.cej.2015.10.090</pub-id> </citation>
</ref>
</ref-list>
</back>
</article>