<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Energy Res.</journal-id>
<journal-title>Frontiers in Energy Research</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Energy Res.</abbrev-journal-title>
<issn pub-type="epub">2296-598X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fenrg.2019.00045</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Energy Research</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Critical Analysis of <italic>in situ</italic> Performance of Glass Fiber Core VIPs in Extreme Cold Climate</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name><surname>Chan</surname> <given-names>Vivian Ting Ting</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/645277/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Ooms</surname> <given-names>Matthew D.</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/670844/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Korn</surname> <given-names>Juergen</given-names></name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>MacLean</surname> <given-names>Douglas</given-names></name>
<xref ref-type="aff" rid="aff4"><sup>4</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Mooney</surname> <given-names>Stephen</given-names></name>
<xref ref-type="aff" rid="aff5"><sup>5</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/669329/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Andre</surname> <given-names>Shane</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name><surname>Mukhopadhyaya</surname> <given-names>Phalguni</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="corresp" rid="c001"><sup>&#x0002A;</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/639092/overview"/>
</contrib>
</contrib-group>
<aff id="aff1"><sup>1</sup><institution>Department of Civil Engineering, University of Victoria</institution>, <addr-line>Victoria, BC</addr-line>, <country>Canada</country></aff>
<aff id="aff2"><sup>2</sup><institution>Yukon Energy Mines and Resources</institution>, <addr-line>Whitehorse, YT</addr-line>, <country>Canada</country></aff>
<aff id="aff3"><sup>3</sup><institution>Yukon Housing Corporation</institution>, <addr-line>Whitehorse, YT</addr-line>, <country>Canada</country></aff>
<aff id="aff4"><sup>4</sup><institution>Retired, Yukon Energy Mines and Resources</institution>, <addr-line>Whitehorse, YT</addr-line>, <country>Canada</country></aff>
<aff id="aff5"><sup>5</sup><institution>Yukon Research Centre</institution>, <addr-line>Whitehorse, YT</addr-line>, <country>Canada</country></aff>
<author-notes>
<fn fn-type="edited-by"><p>Edited by: Kaushik Biswas, Oak Ridge National Laboratory (DOE), United States</p></fn>
<fn fn-type="edited-by"><p>Reviewed by: Mohammadhasan Fathollahzadeh, Colorado School of Mines, United States; Som Sagar Shrestha, Oak Ridge National Laboratory (DOE), United States</p></fn>
<corresp id="c001">&#x0002A;Correspondence: Phalguni Mukhopadhyaya <email>phalguni&#x00040;uvic.ca</email></corresp>
<fn fn-type="other" id="fn001"><p>This article was submitted to Indoor Environment, a section of the journal Frontiers in Energy Research</p></fn></author-notes>
<pub-date pub-type="epub">
<day>22</day>
<month>05</month>
<year>2019</year>
</pub-date>
<pub-date pub-type="collection">
<year>2019</year>
</pub-date>
<volume>7</volume>
<elocation-id>45</elocation-id>
<history>
<date date-type="received">
<day>15</day>
<month>11</month>
<year>2018</year>
</date>
<date date-type="accepted">
<day>24</day>
<month>04</month>
<year>2019</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x000A9; 2019 Chan, Ooms, Korn, MacLean, Mooney, Andre and Mukhopadhyaya.</copyright-statement>
<copyright-year>2019</copyright-year>
<copyright-holder>Chan, Ooms, Korn, MacLean, Mooney, Andre and Mukhopadhyaya</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license>
</permissions>
<abstract><p>Glass fiber core vacuum insulation panels (VIPs) are becoming an increasingly attractive option for building envelope construction due to lower cost and availability around the world. Although fumed silica core VIPs have shown superior long-term performance under accelerated aging tests compared to glass fiber core VIPS, these laboratory test results have yet to be verified with long-term field performance data. In 2011, glass fiber core VIPs were installed in a commercial building retrofit project in Yukon, Canada (one of Canada&#x00027;s most northern territories), and have been continuously monitored since. This paper summarizes the thermal performance of the glass fiber core VIPs over the period of 2011&#x02013;2018 in an extreme cold climate. Findings from this study provided data to validate glass fiber core VIP accelerated aging test results and the aging rate of VIPs in a cold and dry climate was determined. These results will help developing a better understanding of the long-term performance of glass fiber core VIPs in a real-world context.</p></abstract>
<kwd-group>
<kwd>vacuum insulation panel (VIP)</kwd>
<kwd>glass fiber core</kwd>
<kwd><italic>in situ</italic> performance</kwd>
<kwd>accelerated aging test</kwd>
<kwd>cold climate</kwd>
</kwd-group>
<counts>
<fig-count count="11"/>
<table-count count="0"/>
<equation-count count="0"/>
<ref-count count="13"/>
<page-count count="7"/>
<word-count count="4104"/>
</counts>
</article-meta>
</front>
<body>
<sec sec-type="intro" id="s1">
<title>Introduction</title>
<p>Vacuum insulation panels (VIP) are one of the most promising advanced building insulation materials owing to their low thermal conductivity of about 0.004 W/m&#x000B7;K (Simmler et al., <xref ref-type="bibr" rid="B13">2005</xref>). Traditional thermal insulation materials such as mineral wool, expanded polystyrene, extruded polystyrene, cellulose etc. are in the range of 0.025&#x02013;0.040 W/m&#x000B7;K , have thermal conductivities 5&#x02013;10 times higher than that of VIPs (Jelle, <xref ref-type="bibr" rid="B3">2011</xref>). Integration of VIPs into building envelopes can help builders meet increasingly stringent code requirements, particularly when space is limited, and allow for greater aesthetic flexibility in architectural design. In spite of these benefits, VIPs have not been broadly adopted because of their high cost, concerns related to long-term effectiveness, thermal bridge effects at the panel edges, and the risk of condensation if appropriate moisture control is not considered in the design (Kalnaes and Jelle, <xref ref-type="bibr" rid="B4">2014</xref>). It is worth mentioning that integration and adoption of new materials and technologies in the building construction industry takes time and cannot be done prior to rigorous short- and long-term holistic performance evaluation. This is particularly true in Canada<xref ref-type="fn" rid="fn0001"><sup>1</sup></xref> or insulation because of the significant economic implications that can be expected should the insulation not perform as expected during Canada&#x00027;s long and very cold winters. In the case of VIPs, there are also related concerns about the effects of damage to VIPs during construction and in service, as well as the unknown service life for VIPs.</p>
<p>VIPs consist of an evacuated open-pore core enclosed within a gas-tight envelope, as shown in <xref ref-type="fig" rid="F1">Figure 1</xref>. The core provides thermal resistance and adequate load bearing capacity to resist atmospheric pressure (Heinemann, <xref ref-type="bibr" rid="B2">2017</xref>) while the single/multi-layer sealed envelope maintains the vacuum inside the panel. Opacifiers can be added to the core to reduce radiative heat transfer through the core, and getters/desiccants adsorb residual or permeating gas and moisture (Simmler et al., <xref ref-type="bibr" rid="B13">2005</xref>) and thus slow the aging rate. In these ways, heat transfer across the panel is minimized and the service life is extended.</p>
<fig id="F1" position="float">
<label>Figure 1</label>
<caption><p>Schematic of a glass fiber core VIP. One corner of the gas-tight envelope has been removed to show the evacuated open-pore core. The getter/desiccant is in a sachet in the raised area at the top-center. The brown wax paper backing covers the adhesive that is used to mount the VIP in place.</p></caption>
<graphic xlink:href="fenrg-07-00045-g0001.tif"/>
</fig>
<p>To maintain high thermal performance, VIPs require their internal pressure to be kept very low, close to vacuum (zero). Permeation of dry air (e.g., oxygen and nitrogen) and water vapor through the envelope can compromise this vacuum and lead to an irreversible pressure increase and moisture accumulation inside the panel (Mukhopadhyaya, <xref ref-type="bibr" rid="B8">2006</xref>). Temperature and relative humidity (RH) are the dominant factors impacting the rate of gas permeation through the envelope and consequently the VIP&#x00027;s expected service life.</p>
<p>The most commonly used VIP core materials are fumed silica and glass fiber. Fumed silica core VIPs can achieve thermal conductivities of 0.004 W/m&#x000B7;K when the pore pressure is reduced to 2,000&#x02013;10,000 Pa at room temperature. Fumed silica has a pore size of about 30&#x02013;100 nm and its thermal characteristics are stable up to about 5,000 Pa (Simmler et al., <xref ref-type="bibr" rid="B13">2005</xref>). Among core materials, fumed silica is least sensitive to increases in pressure, and its internal pressure can be satisfactorily maintained with a moderately effective gas-tight envelope. Fumed silica VIPs with laminated aluminum foil envelopes are expected to have service lives of up to 50 years (Simmler et al., <xref ref-type="bibr" rid="B13">2005</xref>; Fricke et al., <xref ref-type="bibr" rid="B1">2006</xref>). Furthermore, even after complete vacuum failure, fumed silica core VIPs can have thermal resistances twice as high (thermal conductivity &#x0003D; 0.020 W/m&#x000B7;K) as conventional insulation materials (Simmler et al., <xref ref-type="bibr" rid="B13">2005</xref>).</p>
<p>In comparison, glass fiber VIPs are able to achieve thermal conductivities as low as 0.002 W/m&#x000B7;K, the lowest of all core materials (MacLean and Korn, <xref ref-type="bibr" rid="B5">2011</xref>) although they require an internal pressure of about 10 Pa to achieve this performance. In addition, the larger pore size (1&#x02013;12 &#x003BC;<italic>m</italic>) of glass fiber cores leads to a rapid increase in thermal conductivity when the internal pressure rises above 100 Pa (Fricke et al., <xref ref-type="bibr" rid="B1">2006</xref>). Nevertheless, glass fiber core VIPs are less expensive to manufacture and therefore remain an attractive alternative as a building material (Simmler et al., <xref ref-type="bibr" rid="B13">2005</xref>). Glass fiber VIPs have been used extensively in the aerospace and refrigerator industries where the expected service life is no more than 15 years (Simmler et al., <xref ref-type="bibr" rid="B13">2005</xref>). While the expected service life of thermal insulation in building construction is 25&#x02013;50 years, broad industry confidence in long-term thermal performance of glass fiber core VIPs still needs to be established.</p>
<p>Glass fiber core VIPs have been used as thermal insulation in retrofitting an existing wall of a commercial building in Whitehorse, Yukon, a subarctic city in Northern Canada. Buildings in Whitehorse typically have high space-heating demands due to the region&#x00027;s extremely cold winters, so interest in high performing building insulation systems is high. This paper is a continuation of a series of publications (MacLean and Korn, <xref ref-type="bibr" rid="B5">2011</xref>; Mukhopadhyaya et al., <xref ref-type="bibr" rid="B9">2011</xref>, <xref ref-type="bibr" rid="B11">2013</xref>, <xref ref-type="bibr" rid="B12">2014</xref>, <xref ref-type="bibr" rid="B10">2017</xref>; MacLean et al., <xref ref-type="bibr" rid="B6">2017</xref>) and presents the most up-to-date field performance data observed from continuous <italic>in situ</italic> monitoring of this installation (2011&#x02013;2018), compares these results to accelerated aging test results presented in the literature, and discusses the lessons learned from VIP handling and installation.</p></sec>
<sec id="s2">
<title>Construction and Instrumentation</title>
<p>An 8.4 &#x000D7; 3.7 m<sup>2</sup> wall of an existing building was retrofitted with VIPs sandwiched between layers of extruded polystyrene foam (XPS) attaching to its concrete exterior. The VIP specimens used were 560 &#x000D7; 460 &#x000D7; 12 mm in size. The pre-installation thermal conductivity of the VIPs was measured using a 600 &#x000D7; 600 mm heat flow meter apparatus with 300 &#x000D7; 300 mm heat flow sensor and an accuracy of &#x000B1; 2%, the thermal conductivity was found to be 0.0034 W/m&#x000B7;K at the center of the panel (Mukhopadhyaya et al., <xref ref-type="bibr" rid="B12">2014</xref>).</p>
<p>The existing exterior concrete block wall (<xref ref-type="fig" rid="F2">Figure 2</xref>) was insulated with fiberglass batts. The thermal resistance of this existing wall was about 3.5 m<sup>2</sup>.K/W, and the retrofitting goal was to increase the wall&#x00027;s thermal resistance to 8.8&#x02013;10.6 m<sup>2</sup>.K/W (Mukhopadhyaya et al., <xref ref-type="bibr" rid="B12">2014</xref>). The integrity of VIPs was verified by physical examination at the construction site before the assembly. Concerns regarding condensation in additional wall layers and mechanical rubbing on VIP surfaces caused by uneven proximate wall elements were addressed in the design described below (Mukhopadhyaya et al., <xref ref-type="bibr" rid="B12">2014</xref>). In summary, additional layers of insulation were constructed on the exterior of the existing concrete block wall in the following order (Mukhopadhyaya et al., <xref ref-type="bibr" rid="B12">2014</xref>):</p>
<list list-type="simple">
<list-item><p>- First, a 0.15 mm polyethylene air-vapor-moisture barrier was glued to the concrete block wall to minimize condensation in extra wall layers.</p></list-item>
<list-item><p>- Then, 25 mm extruded polystyrene (XPS) board was adhered to the polyethylene barrier, creating an even surface for subsequent mounting of the VIPs.</p></list-item>
<list-item><p>- 50 &#x000D7; 75 mm wood strapping was then attached over top of the XPS board and affixed to the concrete wall with anchors.</p></list-item>
<list-item><p>- Glass fiber core VIPs were adhered to the XPS board between the wood straps, using a &#x0201C;peel and stick&#x0201D; adhesive on one side.</p></list-item>
<list-item><p>- The VIPs were then covered with a layer of 6 mm flexible polyurethane foam that was held in place with sheathing tape.</p></list-item>
<list-item><p>- Lastly, a layer of 25 mm thick polystyrene board was installed over the polyurethane foam to avoid the potential risk of condensation and damage from mechanical rubbing.</p></list-item>
</list>
<fig id="F2" position="float">
<label>Figure 2</label>
<caption><p>Existing wall selected for retrofit (MacLean and Korn, <xref ref-type="bibr" rid="B5">2011</xref>).</p></caption>
<graphic xlink:href="fenrg-07-00045-g0002.tif"/>
</fig>
<p>Installations proceeded quickly and smoothly as documented in <xref ref-type="fig" rid="F2">Figures 2</xref>&#x02013;<xref ref-type="fig" rid="F5">5</xref>.</p>
<fig id="F3" position="float">
<label>Figure 3</label>
<caption><p>Installation of VIPs over a layer of XPS and a 0.15 mm (6 mil) polyethylene air vapor barrier on the existing concrete block wall (MacLean and Korn, <xref ref-type="bibr" rid="B5">2011</xref>).</p></caption>
<graphic xlink:href="fenrg-07-00045-g0003.tif"/>
</fig>
<fig id="F4" position="float">
<label>Figure 4</label>
<caption><p>The second layer of XPS is shown in place over 6 mm polyurethane foam. The XPS layer ensured that the bottom surface of each VIP was attached to a smooth surface and protected from abrasion. A layer of 6 mm flexible polyurethane foam was placed over the exterior surface of the VIPs to help prevent mechanical rubbing of the outside surface of each VIP against the 25 mm polystyrene foam board placed on top of it.</p></caption>
<graphic xlink:href="fenrg-07-00045-g0004.tif"/>
</fig>
<fig id="F5" position="float">
<label>Figure 5</label>
<caption><p>Post-retrofit wall (MacLean and Korn, <xref ref-type="bibr" rid="B5">2011</xref>). Because all holes for fasteners were drilled before the siding was put on the wall, it was possible to visually check that all fastening points were directly over the support members.</p></caption>
<graphic xlink:href="fenrg-07-00045-g0005.tif"/>
</fig>
<p>Four thermistors were installed to monitor the temperature at the interface between insulation layers, as shown schematically in <xref ref-type="fig" rid="F6">Figure 6</xref>. These thermistors were set up &#x0007E;2 m from the south edge of the wall and 1 m down from the top of the wall (Mukhopadhyaya et al., <xref ref-type="bibr" rid="B12">2014</xref>). Three sensors were placed on the existing wall &#x0007E;2 m from the north edge of the wall retrofitted area. These sensors were located &#x0007E;1, 1.5, and 3 m from the top of the wall, and they were used to monitor the thermal gradients from the top to the bottom of the wall (Mukhopadhyaya et al., <xref ref-type="bibr" rid="B12">2014</xref>).</p>
<fig id="F6" position="float">
<label>Figure 6</label>
<caption><p>Schematic diagram of the retrofitted wall cross-section starting from cladding onwards and the locations of the temperature sensors (thermistors) (MacLean and Korn, <xref ref-type="bibr" rid="B5">2011</xref>). This drawing is not to scale. Two sets of thermistors are installed at different locations along the length of the wall (one set is near the north edge and the other is near the south edge).</p></caption>
<graphic xlink:href="fenrg-07-00045-g0006.tif"/>
</fig></sec>
<sec id="s3">
<title>Results and Discussions</title>
<p>Infrared thermal images of the retrofitted wall were taken in 2011, 2014, 2016, and 2018 are shown in <xref ref-type="fig" rid="F7">Figure 7</xref>. These images confirm that all VIPs installed in 2011 remain functional after 8 years. Specifically, it is clear from the temperature of the wall over each VIP that none of the VIPs have lost their insulating value over 8 years (failed VIPs will be indicated by abrupt change of color in the infrared thermal images). This is a very significant finding for the long-term performance of glass fiber core VIPs in an extreme cold climate and demonstrates the effective integration of VIPs in an exterior building envelope retrofit. In order to gain greater insight into the thermal performance of the exterior wall and VIPs, the temperatures at the interfaces between insulation layers of the retrofitted wall were collected over the past 8 years (2011&#x02013;2018) since the project started, and selected data were analyzed for the following colder winter time periods (summer data were not stable due to factors such as lack of thermal gradient, unstable indoor condition etc.):</p>
<list list-type="bullet">
<list-item><p>December 13, 2011&#x02013;April 15, 2012</p></list-item>
<list-item><p>December 5, 2012&#x02013;May 23, 2013</p></list-item>
<list-item><p>November 1, 2013&#x02013;January 9, 2014</p></list-item>
<list-item><p>February 11, 2016&#x02013;March 31, 2016</p></list-item>
<list-item><p>November 1, 2016&#x02013;January 11, 2017</p></list-item>
<list-item><p>March 24, 2018&#x02013;June 8, 2018</p></list-item>
</list>
<fig id="F7" position="float">
<label>Figure 7</label>
<caption><p>Infrared images of the pre-retrofit and post-retrofit wall. Images were taken in 2011, 2014, 2016, and 2018.</p></caption>
<graphic xlink:href="fenrg-07-00045-g0007.tif"/>
</fig>
<p>The temperature drops across each layer of the composite exterior insulation (XPS-VIP-XPS) were calculated as a percentage of total temperature drop across the composite exterior insulation. A sample calculation can be found in <xref ref-type="supplementary-material" rid="SM1">Appendix A</xref>. <xref ref-type="fig" rid="F8">Figure 8</xref> shows the percentage of total temperature drop across each insulation layer averaged over the winter and/or spring months for six selected years. The average temperature drop for the VIP layer is about 66.49%, while that for the first (interior) and second (exterior) layers of XPS are 14.48 and 18.95%, respectively. The exterior layer of XPS is a more effective thermal insulator than the identical interior XPS layer due to the cooler exterior temperature. This observation clearly validates a very basic physical principle of heat transfer and generates confidence in the recorded data and the analysis procedure. The graphical representation in <xref ref-type="fig" rid="F8">Figure 8</xref> shows that the effectiveness of the VIP layer is decreasing very slowly, from about 69% initially in winter 2011 to 63% in spring 2018, at an average rate of 0.9% per annum, and this rate of aging appears to be linear. However, it is to be noted that the aging rate of VIPs cannot be linear forever and it is expected to increase rapidly as the internal pressure approaches atmospheric pressure. The transition from lower aging rate to higher aging rate depends on the functional relationship between thermal conductivity and internal pore pressure of the VIP core material.</p>
<fig id="F8" position="float">
<label>Figure 8</label>
<caption><p>Percentage of temperature drop across wall components, relative to the drop across the entire wall. Data averaged for the winter months 2011&#x02013;2017 and spring months of 2018.</p></caption>
<graphic xlink:href="fenrg-07-00045-g0008.tif"/>
</fig></sec>
<sec id="s4">
<title>Accelerated Aging and <italic>in situ</italic> Performance</title>
<p>Accelerated aging tests were conducted, at the National Research Council (NRC) Canada, in 2011 to establish long-term thermal performance of the glass fiber core VIPs used in this study (Mukhopadhyaya et al., <xref ref-type="bibr" rid="B12">2014</xref>). Three VIP specimens (560 &#x000D7; 460 &#x000D7; 12 mm) were tested under cyclic exposure conditions. In one cycle, VIPs were kept at 23&#x000B0;C, 95% RH for 1 week and then changed to 70&#x000B0;C, 5% RH for the next week. The specimens went through 14 weeks of total exposure (i.e., a total of seven cycles). The thermal resistance of the panels was measured at the end of each week using a 600 &#x000D7; 600 mm heat flow meter. One specimen failed after 8 weeks, and the average linear aging rate of the other two was found to be about 3.29% (Morlidge, <xref ref-type="bibr" rid="B7">2012</xref>) per cycle as shown in <xref ref-type="fig" rid="F9">Figure 9</xref>. The normalized <italic>in situ</italic> VIP aging rate (expressed as the percentage of its initial thermal resistance) was also plotted with the average of accelerated aging test results in <xref ref-type="fig" rid="F9">Figure 9</xref>. It can be observed from the plot, that the 2-year <italic>in situ</italic> aging rate is nearly equal to one cycle (two weeks) of the accelerated aging rate for the time period where field data are available. Based on this correlation, the linear extrapolation of the <italic>in situ</italic> data predicts that the total reduction of thermal resistance in 2026 (14 years since construction) will be about 21% (thermal conductivity increased from 0.0034 to 0.00429 W/m&#x000B7;K).</p>
<fig id="F9" position="float">
<label>Figure 9</label>
<caption><p>Aging rate of glass fiber core VIP in terms of its pristine thermal resistance as a function of time determined from <italic>in situ</italic> performance and laboratory accelerated aging test results.</p></caption>
<graphic xlink:href="fenrg-07-00045-g0009.tif"/>
</fig>
<p>The small divergence between the accelerated aging test and the actual field performance of VIPs could be attributed to the different environmental (boundary) conditions that the VIPs were exposed to. Accelerated aging tests were conducted with the exposure in cyclic conditions of extreme high temperature and relative humidity (23&#x000B0;C, 95% and 70&#x000B0;C, 5%), while the <italic>in situ</italic> performance study was carried out in the subarctic climate of Whitehorse, Yukon with lower temperatures and high RH [an average of &#x02212;13&#x000B0;C and 75% RH over winter months and an average of 11.5&#x000B0;C and 62% RH over summer months]<xref ref-type="fn" rid="fn0002"><sup>2</sup></xref>. Since the permeability of gas through the VIPs envelope increases with temperature, the VIP aging rate is slower when subjected to lower temperatures. It is also to be noted that the XPS foam on both sides of the VIPs resisted water vapor movement and absorbed some amount of water vapor, thus buffering the VIP&#x00027;s exposure to moisture. Overall, the linear aging trends from <italic>in situ</italic> measurements and laboratory accelerated aging test results are quite similar. Additional field and accelerated aging test observations are required to elaborate on the relationship between VIP type, environment and comparison to laboratory tests and to establish more general rules or protocols for the prediction of long-term performance of glass fiber core VIPs.</p></sec>
<sec id="s5">
<title>Prediction of Service Life</title>
<p>The typical relationships between the thermal conductivity and internal pore pressure for glass fiber and fumed silica core VIPs are shown in <xref ref-type="fig" rid="F10">Figure 10</xref> (Fricke et al., <xref ref-type="bibr" rid="B1">2006</xref>). These relationships clearly indicate that the rate of increasing thermal conductivity with pore pressure (i.e., the aging rate) of VIPs is not linear during their service life. Derived from <xref ref-type="fig" rid="F10">Figure 10</xref>, <xref ref-type="fig" rid="F11">11</xref> shows the aging of glass fiber and fumed silica core VIPs in terms of their initial thermal resistance as a function of internal gas pressure.</p>
<fig id="F10" position="float">
<label>Figure 10</label>
<caption><p>Typical thermal conductivity of glass fiber and fumed silica VIPs as a function of internal pore gas (air) pressure (Heinemann, <xref ref-type="bibr" rid="B2">2017</xref>).</p></caption>
<graphic xlink:href="fenrg-07-00045-g0010.tif"/>
</fig>
<fig id="F11" position="float">
<label>Figure 11</label>
<caption><p>Aging of glass fiber and fumed silica core VIPs in terms of their initial thermal resistance as a function of gas (air) pressure (derived from <xref ref-type="fig" rid="F10">Figure 10</xref>).</p></caption>
<graphic xlink:href="fenrg-07-00045-g0011.tif"/>
</fig>
<p><xref ref-type="fig" rid="F11">Figure 11</xref> indicates that glass fiber core VIPs lose about 20% of their initial thermal resistance when the internal pore pressure reaches about 10 Pa and that this change of thermal resistance is almost a linear function of time. However, <xref ref-type="fig" rid="F10">Figure 10</xref> also shows that the thermal conductivity of glass fiber core VIPs will rise at a much faster rate between an internal pressure of 10 Pa and 100 Pa, but still thermal conductivity stays below 0.007 W/m&#x000B7;K at 100 Pa internal pore pressure. These observations further reinforce the relationship between accelerated aging and <italic>in situ</italic> performance of glass fiber core VIP presented in the previous section. Though <italic>in situ</italic> decrease in the thermal resistance is found to be slow and vary linearly with time until now. It is expected that the thermal resistance of glass fiber core VIPs will eventually decrease at a much faster rate. Hence, the <italic>in situ</italic> performance observations in the coming years will be of particular interest and will help us to establish the true relationship between accelerated aging test results and the long-term <italic>in situ</italic> performance of glass fiber core VIPs.</p></sec>
<sec id="s6">
<title>Conclusions and Outlook</title>
<p>The results from the energy retrofit project in the Canadian subarctic climate in Whitehorse, Yukon, using a foam-VIP-foam sandwich (i.e., XPS-VIP-XPS) insulation have demonstrated the promising and satisfactory performance of glass fiber core VIPs over a period of 8 years. Analysis of the temperature data from monitoring each insulation layer over a period of 8 years (2011&#x02013;2018) has shown a &#x0003C;0.9% per year change in the field thermal performance of the VIPs, which indicates that aging of glass fiber core VIPs in cold climate proceeds at a very slow rate. Moreover, this project has shown that many perceived challenges (i.e., handling, installation, etc.) relating to the application of VIPs in the construction industry could be addressed through careful planning and detailing. Ongoing <italic>in situ</italic> temperature monitoring of this project provides valuable field data that can be used for validating theoretical VIP aging predictions and laboratory accelerated aging results.</p></sec>
<sec id="s7">
<title>Author Contributions</title>
<p>All authors listed have made a substantial, direct and intellectual contribution to the work, and approved it for publication.</p>
<sec>
<title>Conflict of Interest Statement</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p></sec></sec>
</body>
<back>
<ack><p>The authors appreciate the support of Panasonic Canada Inc. and Panasonic Corporation for supplying the vacuum insulation panels used for this project. The authors gratefully acknowledge the National Research Council Canada (NRCC) for providing technical expertise and support. The authors would like to thank Yukon Housing Corporation for providing a wall on one of their buildings for this project, and for providing monitoring equipment and for assistance with data collection and handling. Cold Climate Innovation, Yukon Research Centre, Yukon College, and the Energy Solutions Centre must also be credited for providing financial and technical supports for this collaborative project.</p>
</ack>
<sec sec-type="supplementary-material" id="s8">
<title>Supplementary Material</title>
<p>The Supplementary Material for this article can be found online at: <ext-link ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/fenrg.2019.00045/full#supplementary-material">https://www.frontiersin.org/articles/10.3389/fenrg.2019.00045/full#supplementary-material</ext-link></p>
<supplementary-material xlink:href="Data_Sheet_1.docx" id="SM1" mimetype="application/vnd.openxmlformats-officedocument.wordprocessingml.document" xmlns:xlink="http://www.w3.org/1999/xlink"/></sec>
<ref-list>
<title>References</title>
<ref id="B1">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fricke</surname> <given-names>J.</given-names></name> <name><surname>Schwab</surname> <given-names>H.</given-names></name> <name><surname>Heinemann</surname> <given-names>U.</given-names></name></person-group> (<year>2006</year>). <article-title>Vacuum insulation panels - exciting thermal properties and most challenging applications</article-title>. <source>Int. J. Thermophys.</source> <volume>27</volume>, <fpage>1123</fpage>&#x02013;<lpage>1139</lpage>. <pub-id pub-id-type="doi">10.1007/s10765-006-0106-6</pub-id></citation></ref>
<ref id="B2">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Heinemann</surname> <given-names>U.</given-names></name></person-group> (<year>2017</year>). <source>Long-Term Performance of Super-Insulating Materials in Building Components and Systems.</source> Energy in Buildings and Communities Programme.</citation></ref>
<ref id="B3">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jelle</surname> <given-names>B.</given-names></name></person-group> (<year>2011</year>). <article-title>Traditional, state-of-the-art and future thermal building insulation materials and solutions - properties, requirements and possibilities</article-title>. <source>Energy Build.</source> <volume>43</volume>, <fpage>2549</fpage>&#x02013;<lpage>2563</lpage>. <pub-id pub-id-type="doi">10.1016/j.enbuild.2011.05.015</pub-id></citation></ref>
<ref id="B4">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kalnaes</surname> <given-names>S.</given-names></name> <name><surname>Jelle</surname> <given-names>B.</given-names></name></person-group> (<year>2014</year>). <article-title>Vacuum insulation panel products: a state-of-the-art review and future research pathways</article-title>. <source>Appl. Energy</source> <volume>116</volume>, <fpage>355</fpage>&#x02013;<lpage>375</lpage>. <pub-id pub-id-type="doi">10.1016/j.apenergy.2013.11.032</pub-id></citation></ref>
<ref id="B5">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>MacLean</surname> <given-names>D.</given-names></name> <name><surname>Korn</surname> <given-names>J. Mukhopadhyaya, P.</given-names></name></person-group> (<year>2011</year>). <article-title>&#x0201C;Vacuum Insulation Panels (VIPs) Arrive in Northern Canada: Institutional Building Pilot Retrofit in Yukon,&#x0201D;</article-title> in <source>Proceedings of 10th International Vacuum Insulation Symposium (IVIS-X)</source> (<publisher-loc>Ottawa, ON</publisher-loc>), 10.</citation></ref>
<ref id="B6">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>MacLean</surname> <given-names>D.</given-names></name> <name><surname>Mukhopadhyaya</surname> <given-names>P.</given-names></name> <name><surname>Korn</surname> <given-names>J.</given-names></name> <name><surname>Mooney</surname> <given-names>S.</given-names></name></person-group> (<year>2017</year>). <article-title>Design details and long-term performance of VIPs in Canada&#x00027;s North</article-title>. <source>Energy Proc.</source> <volume>111</volume>, <fpage>481</fpage>&#x02013;<lpage>489</lpage>. <pub-id pub-id-type="doi">10.1016/j.egypro.2017.03.210</pub-id></citation></ref>
<ref id="B7">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Morlidge</surname> <given-names>M.</given-names></name></person-group> (<year>2012</year>). <source>Determining the aging performance of vacuum insulation panels: development of a prediction model</source> (<publisher-loc>MASc thesis</publisher-loc>). Ryerson University, Toronto, ON, Canada.</citation></ref>
<ref id="B8">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mukhopadhyaya</surname> <given-names>P.</given-names></name></person-group> (<year>2006</year>). <source>High Performance Vacuum Insulation Panel - Research Update From Canada</source>. Global Insulation Magazine, <fpage>9</fpage>&#x02013;<lpage>15</lpage>.</citation></ref>
<ref id="B9">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Mukhopadhyaya</surname> <given-names>P.</given-names></name> <name><surname>Kumaran</surname> <given-names>M. K</given-names></name> <name><surname>Sherrer G. van Reenen</surname> <given-names>D.</given-names></name></person-group> (<year>2011</year>). <article-title>&#x0201C;An investigation on long-term thermal performance of Vacuum Insulation Panels (VIPs),&#x0201D;</article-title> in <source>Proceedings of 10th International Vacuum Insulation Symposium (IVIS-X)</source> (<publisher-loc>Ottawa, ON</publisher-loc>), 10.</citation></ref>
<ref id="B10">
<citation citation-type="book"><person-group person-group-type="author"><name><surname>Mukhopadhyaya</surname> <given-names>P.</given-names></name> <name><surname>MacLean</surname> <given-names>D.</given-names></name> <name><surname>Korn</surname> <given-names>J.</given-names></name> <name><surname>Mooney</surname> <given-names>S.</given-names></name></person-group> (<year>2017</year>). <source>Application of VIPs in Canada&#x00027;s North - Monitoring Results&#x00027; ASTM International, STP1599</source>. <publisher-loc>West Conshohocken, PA</publisher-loc>: <publisher-name>ASTM International</publisher-name>, <fpage>122</fpage>&#x02013;<lpage>131</lpage>.</citation></ref>
<ref id="B11">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mukhopadhyaya</surname> <given-names>P.</given-names></name> <name><surname>MacLean</surname> <given-names>D.</given-names></name> <name><surname>Korn</surname> <given-names>J.</given-names></name> <name><surname>van Reenen</surname> <given-names>D.</given-names></name> <name><surname>Molleti</surname> <given-names>S.</given-names></name></person-group> (<year>2013</year>). <article-title>&#x0201C;Field application and long-term thermal performance of Vacuum Insulation Panels (VIPs) in Canadian Arctic Climate,&#x0201D;</article-title> in <source>Proceedings of 11th International Vacuum Insulation Symposium (IVIS-XI)</source>, 97&#x02013;98.</citation></ref>
<ref id="B12">
<citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mukhopadhyaya</surname> <given-names>P.</given-names></name> <name><surname>MacLean</surname> <given-names>D.</given-names></name> <name><surname>Korn</surname> <given-names>J.</given-names></name> <name><surname>van Reenen</surname> <given-names>D.</given-names></name> <name><surname>Molleti</surname> <given-names>S.</given-names></name></person-group> (<year>2014</year>). <article-title>Building application and thermal performance of vacuum insulation panels (VIPs) in Canadian subarctic climate</article-title>. <source>Energy Build.</source> <volume>85</volume>, <fpage>672</fpage>&#x02013;<lpage>680</lpage>. <pub-id pub-id-type="doi">10.1016/j.enbuild.2014.08.038</pub-id></citation></ref>
<ref id="B13">
<citation citation-type="web"><person-group person-group-type="author"><name><surname>Simmler</surname> <given-names>H.</given-names></name> <name><surname>Brunner</surname> <given-names>S.</given-names></name> <name><surname>Heinemann</surname> <given-names>U.</given-names></name> <name><surname>Schwab</surname> <given-names>H.</given-names></name> <name><surname>Kumaran</surname> <given-names>K. P.</given-names></name> <name><surname>Mukhopadhyaya</surname> <given-names>P.</given-names></name> <etal/></person-group>. (<year>2005</year>). <source>Study on VIP-Components and Panels for Service Life Prediction of VIP in Building Applications (Subtask A). HiPTI - High Performance Thermal Insulation, IEA/ECBCS Annex 39, 1&#x02013;159</source>. Available online at: <ext-link ext-link-type="uri" xlink:href="https://en.wikipedia.org/wiki/R-value_%28insulation%29">https://en.wikipedia.org/wiki/R-value_%28insulation%29</ext-link></citation></ref>
</ref-list>
<fn-group>
<fn id="fn0001"><p><sup>1</sup>Canadian Construction Materials Centre&#x02014;About the CCMC, National Research Council Canada, 16 11 2016. Available: <ext-link ext-link-type="uri" xlink:href="https://www.nrc-cnrc.gc.ca/eng/solutions/advisory/ccmc/about_ccmc.html">https://www.nrc-cnrc.gc.ca/eng/solutions/advisory/ccmc/about_ccmc.html</ext-link>. (accessed January, 2019).</p></fn>
<fn id="fn0002"><p><sup>2</sup>Climate and Weather Averages in Whitehorse, Yukon, Canada. Time and Date, 1995-2017. Available online at: <ext-link ext-link-type="uri" xlink:href="https://www.timeanddate.com/weather/canada/whitehorse/climate">https://www.timeanddate.com/weather/canada/whitehorse/climate</ext-link>. (accessed June11, 2017).</p></fn>
</fn-group>
<fn-group>
<fn fn-type="financial-disclosure"><p><bold>Funding.</bold> Funded by Energy Mines and Resources (Yukon Government).</p></fn>