<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" article-type="research-article" dtd-version="2.3" xml:lang="EN">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Cell. Infect. Microbiol.</journal-id>
<journal-title>Frontiers in Cellular and Infection Microbiology</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Cell. Infect. Microbiol.</abbrev-journal-title>
<issn pub-type="epub">2235-2988</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fcimb.2025.1607905</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Cellular and Infection Microbiology</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>A comparative study on the cleaning efficacy of a pulsed vacuum cleaning and disinfection device on rigid endoscopic instruments in a hospital setting</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Bo</surname>
<given-names>Licong</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/data-curation/"/>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Wang</surname>
<given-names>Xue</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="author-notes" rid="fn001">
<sup>*</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/3029423/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/data-curation/"/>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/supervision/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Li</surname>
<given-names>Jian</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Hu</surname>
<given-names>Yue</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/data-curation/"/>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-review-editing/"/>
</contrib>
</contrib-group>
<aff id="aff1">
<sup>1</sup>
<institution>Supply Room, Shijiazhuang Maternal and Child Health Hospital</institution>, <addr-line>Shijiazhuang, Hebei</addr-line>,&#xa0;<country>China</country>
</aff>
<aff id="aff2">
<sup>2</sup>
<institution>Operating Room, Shijiazhuang Maternal and Child Health Hospital</institution>, <addr-line>Shijiazhuang, Hebei</addr-line>,&#xa0;<country>China</country>
</aff>
<author-notes>
<fn fn-type="edited-by">
<p>Edited by: Ziad A. Memish, Alfaisal University, Saudi Arabia</p>
</fn>
<fn fn-type="edited-by">
<p>Reviewed by: Tony Buhr, NAVSEA, United States</p>
<p>Leandro Proc&#xf3;pio Alves, Anhembi Morumbi University, Brazil</p>
</fn>
<fn fn-type="corresp" id="fn001">
<p>*Correspondence: Xue Wang, <email xlink:href="mailto:947179524@qq.com">947179524@qq.com</email>
</p>
</fn>
</author-notes>
<pub-date pub-type="epub">
<day>15</day>
<month>08</month>
<year>2025</year>
</pub-date>
<pub-date pub-type="collection">
<year>2025</year>
</pub-date>
<volume>15</volume>
<elocation-id>1607905</elocation-id>
<history>
<date date-type="received">
<day>09</day>
<month>04</month>
<year>2025</year>
</date>
<date date-type="accepted">
<day>22</day>
<month>07</month>
<year>2025</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2025 Bo, Wang, Li and Hu.</copyright-statement>
<copyright-year>2025</copyright-year>
<copyright-holder>Bo, Wang, Li and Hu</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<sec>
<title>Objective</title>
<p>Given the increasing demand for rapid and reliable instrument reprocessing to support surgical schedules and minimize infection risks, this study aims to explore the cleaning efficacy of a pulsed vacuum cleaning and disinfection device on rigid endoscopic instruments in a comparative hospital setting.</p>
</sec>
<sec>
<title>Methods</title>
<p>A total of 800 rigid endoscopic instruments scheduled for post-operative cleaning in our hospital&#x2019;s sterilization supply room between July and December 2024 were included in the study. After pre-treatment, the instruments were divided into two groups, with 400 instruments in each group. The control group used a vacuum ultrasonic cleaner, while the observation group used a pulsed vacuum cleaning and disinfection device. The cleaning time, cleaning effect, protein residue detection, and instrument damage rate were compared between the two groups. A cost-effectiveness analysis was also performed.</p>
</sec>
<sec>
<title>Results</title>
<p>The cleaning time in the observation group was significantly shorter than that in the control group, with a statistically significant difference (P&lt;0.05). There was no statistically significant difference between the two groups in terms of visual inspection, magnifying light source, and ATP fluorescence comparison (P&gt;0.05). The protein residue detection in the observation group was lower than that in the control group, with a statistically significant difference (P&lt;0.05). The instrument damage rate in the observation group was lower than that in the control group, with a statistically significant difference (P&lt;0.05). The pulsed vacuum device demonstrated significant cost savings, with a lower total cost ($15,984 vs. $21,832) and cost per qualified instrument ($40.26 vs. $55.98) over 400 cycles.</p>
</sec>
<sec>
<title>Conclusion</title>
<p>The pulsed vacuum cleaning and disinfection device can effectively clean rigid endoscopic instruments and is worthy of clinical promotion as it enhances operational efficiency and upholds high standards of patient safety by ensuring instrument cleanliness.</p>
</sec>
</abstract>
<kwd-group>
<kwd>pulsed vacuum cleaning and disinfection device</kwd>
<kwd>rigid endoscopic instruments</kwd>
<kwd>decontamination</kwd>
<kwd>instrument damage</kwd>
<kwd>protein residue</kwd>
</kwd-group>
<counts>
<fig-count count="4"/>
<table-count count="5"/>
<equation-count count="0"/>
<ref-count count="38"/>
<page-count count="10"/>
<word-count count="5145"/>
</counts>
<custom-meta-wrap>
<custom-meta>
<meta-name>section-in-acceptance</meta-name>
<meta-value>Clinical Infectious Diseases</meta-value>
</custom-meta>
</custom-meta-wrap>
</article-meta>
</front>
<body>
<sec id="s1" sec-type="intro">
<label>1</label>
<title>Introduction</title>
<p>The sterilization supply room serves as an indispensable hospital department responsible for cleaning, disinfecting, and sterilizing medical instruments used in clinical operations, thereby ensuring a sterile healthcare environment where the quality of disinfection and sterilization directly impacts medical service functionality, hospital standards, and the incidence of hospital-acquired infections and adverse events (<xref ref-type="bibr" rid="B26">Protano et&#xa0;al., 2019</xref>; <xref ref-type="bibr" rid="B16">Hu et&#xa0;al., 2024</xref>). Infections linked to inadequately reprocessed endoscopic instruments represent a significant patient safety concern, with global outbreaks of multidrug-resistant organisms underscoring the critical need for highly effective reprocessing methods. Recent evidence reviews demonstrate that persistent contamination on patient-ready endoscopes remains a critical issue, with outbreaks frequently linked to reprocessing failures despite adherence to standard protocols, as highlighted by studies showing ongoing pathogen transmission events even after design improvements and staff training enhancements (<xref ref-type="bibr" rid="B5">Benowitz et&#xa0;al., 2020</xref>; <xref ref-type="bibr" rid="B6">Casini et&#xa0;al., 2023</xref>). Structural vulnerabilities in complex endoscope designs&#x2014;such as narrow lumens, internal microdamage, and multi-channel configurations&#x2014;allow them to harbor biofilms that are highly resistant to standard decontamination and serve as reservoirs for pathogen transmission, a phenomenon corroborated by microbiological surveillance confirming biofilm persistence post-reprocessing under international guidelines (<xref ref-type="bibr" rid="B6">Casini et&#xa0;al., 2023</xref>; <xref ref-type="bibr" rid="B17">Kwakman et&#xa0;al., 2023</xref>). Recent studies systematically document these patterns, revealing that duodenoscope contamination rates remain problematic even with enhanced protocols, as outbreaks of AmpC-producing E. coli and CRE infections occurred when recommended reprocessing proved insufficient (<xref ref-type="bibr" rid="B30">Scholz et&#xa0;al., 2023</xref>) while emerging sterilization technologies like peracetic acid chemical sterilization show promise but require validation against stringent sterility assurance levels (SAL of 10<sup>-6</sup>) to prevent cross-contamination (<xref ref-type="bibr" rid="B29">Rutala and Weber, 2016</xref>). The global crisis of multidrug-resistant organisms (MDROs) amplifies these risks, demanding a shift towards next-generation reprocessing technologies capable of overcoming biofilm resilience (<xref ref-type="bibr" rid="B28">Rotello, 2023</xref>). This highlights an urgent need for mandatory outbreak reporting, redesigned endoscopes, and the adoption of validated reprocessing protocols, with recent studies continuing to reveal inconsistencies in practices worldwide (<xref ref-type="bibr" rid="B2">Al Mayahi et&#xa0;al., 2019</xref>; <xref ref-type="bibr" rid="B24">Ofstead et&#xa0;al., 2022</xref>).</p>
<p>In recent years, China&#x2019;s healthcare industry has expanded significantly, with a large-scale increase in the use of minimally invasive instruments, rigid endoscopic devices, and dental surgical instruments. Consequently, the volume of instruments processed in sterilization supply rooms has risen, which demands higher cleaning and disinfection standards (<xref ref-type="bibr" rid="B18">Liu et&#xa0;al., 2021</xref>). Rigid endoscopic instruments, in particular, pose greater challenges due to their complex internal structures, high precision, and special materials. During surgery, blood and other contaminants are often retained within the instrument, making them more difficult to clean than standard surgical tools (<xref ref-type="bibr" rid="B25">Pereira et&#xa0;al., 2015</xref>). If not thoroughly cleaned, these residues can form biofilms that hinder the penetration of sterilizing agents, thereby affecting the sterilization effectiveness and increasing the risk of infection (<xref ref-type="bibr" rid="B35">Wang et&#xa0;al., 2023</xref>). This entire process, from point-of-use pre-treatment to final sterilization, relies on clear protocols and diligent execution by healthcare staff, highlighting the importance of interprofessional collaboration between operating room and sterilization department teams to address operational inefficiencies such as staffing time mismatches (<xref ref-type="bibr" rid="B15">Hu et&#xa0;al., 2023</xref>). The active participation and competence of staff are fundamental to achieving optimal outcomes, as evidenced by interventions that improve timely cleaning practices and reduce biofilm formation risks (<xref ref-type="bibr" rid="B14">Hu et&#xa0;al., 2023</xref>).</p>
<p>Traditional cleaning methods for rigid endoscopic instruments typically involve flushing techniques. However, cleaning machines that interface with these devices face limitations in cleaning capacity and quality, as the design restricts the number of instruments processed per cycle. This method no longer meets the demands of modern hospitals for the cleaning of such specialized instruments (<xref ref-type="bibr" rid="B8">Choi et&#xa0;al., 2021</xref>). Furthermore, while spray cleaning machines are used, their structural limitations prevent thorough cleaning of rigid endoscopes. Although redesigned flow interfaces have been attempted to address these shortcomings, the cleaning results often fall short of expectations, and the loading time and capacity for cleaning instruments remain constrained (<xref ref-type="bibr" rid="B3">Anderson et&#xa0;al., 2023</xref>).</p>
<p>Ultrasonic cleaning machines, traditionally used for instrument cleaning, also present challenges. These devices cannot perform disinfection and drying simultaneously, nor can they effectively flush out contaminants after cleaning, leading to suboptimal cleaning outcomes due to their inability to remove microscopic biofilm formations consistently (<xref ref-type="bibr" rid="B21">Mirzaei et&#xa0;al., 2020</xref>).</p>
<p>In response to these challenges, the pulsed vacuum cleaning and disinfection device was developed. This device integrates cleaning, rinsing, disinfection, and drying functions into one system, offering a high degree of automation. It has been found to perform well in cleaning minimally invasive instruments and dental surgical tools. The device can accommodate instruments in a variety of loading configurations and quantities without strict requirements, allowing instruments to be placed freely in the cleaning baskets for processing (<xref ref-type="bibr" rid="B7">Chang and Tao, 2019</xref>). This underscores the need for robust training and advanced clinical reasoning among nursing staff, who are pivotal in implementing and overseeing these critical processes (<xref ref-type="bibr" rid="B36">Wilder and Roth, 2012</xref>). The evolution towards more complex surgical instruments necessitates not only technological advancements in cleaning but also a parallel development in the roles and competencies of healthcare professionals, including advanced practice nurses and other specialized non-medical staff within the surgical and sterilization workflow (<xref ref-type="bibr" rid="B20">Lowe et&#xa0;al., 2012</xref>).</p>
<p>Although pulsed vacuum cleaning and disinfection devices have gradually gained popularity in domestic sterilization supply centers, there remains limited research on their application. This study aims to investigate the cleaning effectiveness of the pulsed vacuum cleaning and disinfection device on rigid endoscopic instruments.</p>
</sec>
<sec id="s2" sec-type="materials|methods">
<label>2</label>
<title>Materials and methods</title>
<p>This study was a prospective, non-randomized comparative trial. This manuscript has been prepared in accordance with the Transparent Reporting of Evaluations with Nonrandomized Designs (TREND) statement checklist (<xref ref-type="supplementary-material" rid="SM1">
<bold>Supplementary File 1</bold>
</xref>) (<xref ref-type="bibr" rid="B9">Des Jarlais et&#xa0;al., 2004</xref>).</p>
<sec id="s2_1">
<label>2.1</label>
<title>General information</title>
<p>A total of 800 rigid endoscopic instruments scheduled for post-operative processing in the sterilization supply room of our hospital between July and December 2024 were included in the study. After pre-treatment, the instruments were divided into two groups based on the cleaning method: the control group and the observation group, with 400 instruments in each group.</p>
<sec id="s2_1_1">
<label>2.1.1</label>
<title>Observation group</title>
<p>122 laparoscopes, 97 hysteroscopes, 65 arthroscopes, 47 nephroscopes, 43 prostate resection scopes, 26 thoracoscopes;</p>
</sec>
<sec id="s2_1_2">
<label>2.1.2</label>
<title>Pollution level</title>
<p>265 items with mild contamination, 81 items with moderate contamination, and 54 items with severe contamination;</p>
</sec>
<sec id="s2_1_3">
<label>2.1.3</label>
<title>Usage frequency</title>
<p>102 items used &#x2264;1 time/month, 229 items used 2&#x2013;5 times/month, and 69 items used &#x2265;6 times/month.</p>
</sec>
<sec id="s2_1_4">
<label>2.1.4</label>
<title>Control group</title>
<p>131 laparoscopes, 94 hysteroscopes, 71 arthroscopes, 39 nephroscopes, 43 prostate resection scopes, 22 thoracoscopes;</p>
</sec>
<sec id="s2_1_5">
<label>2.1.5</label>
<title>Pollution level</title>
<p>269 items with mild contamination, 83 items with moderate contamination, and 48 items with severe contamination;</p>
</sec>
<sec id="s2_1_6">
<label>2.1.6</label>
<title>Usage frequency</title>
<p>105 items used &#x2264;1 time/month, 222 items used 2&#x2013;5 times/month, and 73 items used &#x2265;6 times/month.</p>
<p>There was no significant difference in the types of instruments, contamination levels, or usage frequency between the two groups (P&gt;0.05).</p>
<p>Both groups of rigid endoscopic instruments were managed by the same batch of staff in the sterilization supply center, with 11 female members in total. The age range of staff was 25-40 years, with an average age of (32.85&#xb1;5.45) years, and work experience ranging from 3 to 15 years, with an average of (10.09&#xb1;2.87) years. The staff's education levels were as follows: 2 had a technical secondary school diploma, and 9 had a bachelor's degree.</p>
</sec>
</sec>
<sec id="s2_2">
<label>2.2</label>
<title>Methods</title>
<sec id="s2_2_1">
<label>2.2.1</label>
<title>Cleaning tools</title>
<p>The cleaning equipment used in this study included devices produced by Shandong Xinhua Medical, including a pulsed vacuum cleaning machine (Model PC-150L), high-efficiency fully automatic cleaning and disinfection machine (Model super-6000), spray cleaning rack (Model super6000-05E-X), medical drying cabinet (Model YGZ-1600S), and pressure water gun (Model Center-R5).</p>
</sec>
<sec id="s2_2_2">
<label>2.2.2</label>
<title>Detection tools</title>
<p>Detection tools included magnifying glasses with light sources, An Yika protein residue detection device (Model MINIPRO), and test rods (Model PROMICO).</p>
</sec>
<sec id="s2_2_3">
<label>2.2.3</label>
<title>Control group cleaning process using ultrasonic cleaner</title>
<sec id="s2_2_3_1">
<label>2.2.3.1</label>
<title>Manual pre-treatment</title>
<p>The pre-treatment process begins at the point of use in the operating room. Immediately after the surgical procedure, trained personnel wipe external debris from the instruments and flush the internal channels with sterile water to prevent the drying of bioburden and biofilm formation. This initial step is critical for effective downstream processing. After surgery, the rigid endoscopic instruments used during the operation were then placed in designated sealed transport containers and uniformly collected and transported to the hospital&#x2019;s sterilization supply center. The instrument labels were carefully checked to confirm the correct quantity, and the appearance and functionality of the instruments were inspected. The instruments were categorized and placed in cleaning baskets. The instruments were removed from the baskets, and manually disassembled to the smallest units. Under running water, residual blood and stains were rinsed off. If dried blood could not be removed, the instruments were soaked in a 30-40&#xb0;C multi-enzyme cleaning solution. Subsequently, a high-strength water gun was used for rinsing.</p>
</sec>
<sec id="s2_2_3_2">
<label>2.2.3.2</label>
<title>Ultrasonic cleaning</title>
<p>The ultrasonic cleaning machine was embedded in the endoscope cleaning workstation. The first tank was used for ultrasonic cleaning, and multi-enzyme cleaning solution was added to soak the rigid endoscopic instruments. The liquid level needed to be higher than the surface of the instruments. The ultrasonic cleaning program was then activated, with a water temperature set between 30&#x2013;45&#xb0;C and the cleaning time set for a minimum of 5 minutes.</p>
</sec>
<sec id="s2_2_3_3">
<label>2.2.3.3</label>
<title>Spray cleaning and drying</title>
<p>The second tank was used for spray cleaning and drying. The rigid endoscopic instruments were placed in the dedicated baskets and loaded into the spray cleaning and disinfection machine. After closing the loading door, the program was started. High-pressure cold and hot water sprays were used for cleaning, followed by high-temperature drying.</p>
</sec>
</sec>
<sec id="s2_2_4">
<label>2.2.4</label>
<title>Observation group cleaning process using pulsed vacuum cleaning and disinfection machine</title>
<sec id="s2_2_4_1">
<label>2.2.4.1</label>
<title>Manual pre-treatment</title>
<p>The pre-treatment process was the same as the control group.</p>
</sec>
<sec id="s2_2_4_2">
<label>2.2.4.2</label>
<title>Post-pre-treatment cleaning</title>
<p>After pre-cleaning, the instruments were loaded onto a dedicated instrument tray and placed in the pulsed vacuum cleaning and disinfection machine. Based on the number of instruments, the appropriate water level was selected. The suitable loading rack was selected, and the machine cleaning program was set, with the temperature set at 93&#xb0;C and the cleaning time for 2.5 minutes. After cleaning, vacuum drying was performed.</p>
</sec>
</sec>
</sec>
<sec id="s2_3">
<label>2.3</label>
<title>Observation indicators</title>
<sec id="s2_3_1">
<label>2.3.1</label>
<title>Cleaning time</title>
<p>The cleaning time for each group of 400 rigid endoscopic instruments was recorded. The time was counted from the start of manual cleaning until all instruments had been cleaned and the time stopped.</p>
</sec>
<sec id="s2_3_2">
<label>2.3.2</label>
<title>Cleaning effect</title>
<p>The cleaning effect was compared between the two groups. The &#x201c;Hospital Sterilization Supply Center Part 3: Cleaning, Disinfection, and Sterilization Effect Monitoring Standards&#x201d; (<xref ref-type="bibr" rid="B1">Central sterile supply department (CSSD) - part 3: surveillance standard for cleaning, disinfection and sterilization WS310.3-2016, 2017</xref>) was used to evaluate the cleaning quality through visual inspection, magnifying light source observation, and Adenosine Triphosphate (ATP) fluorescence measurement.</p>
</sec>
<sec id="s2_3_3">
<label>2.3.3</label>
<title>Visual inspection</title>
<p>The researcher visually checked whether there were any contaminants on the surface of the rigid endoscopic instruments. For metal aspirators, a special cotton swab was used to wipe the instrument. If no contaminants were found on the instrument surface or the swab showed no color change, the cleaning was considered acceptable. If contaminants were found, the cleaning was considered inadequate.</p>
</sec>
<sec id="s2_3_4">
<label>2.3.4</label>
<title>Magnifying light source observation</title>
<p>The cleaned instruments were examined using a magnifying glass with a light source. If no contaminants (e.g., scale, stains, blood) were visible, the cleaning was considered acceptable; otherwise, it was considered inadequate.</p>
</sec>
<sec id="s2_3_5">
<label>2.3.5</label>
<title>ATP fluorescence detection</title>
<p>Detection rods were used to sample the surface, lumen, and valve of the rigid endoscopic instruments. The relative light units (RLU) were measured after activating the solution. If the RLU value was &#x2264;2000, the cleaning was considered acceptable; if it was higher, the cleaning was considered inadequate.</p>
</sec>
<sec id="s2_3_6">
<label>2.3.6</label>
<title>Protein residue detection</title>
<p>Protein residue was quantified using a protein residue test kit based on the biuret method. For each instrument, sampling was performed by swabbing a standardized 10 cm&#xb2; surface area of a critical site (a joint or lumen opening). The swab was processed according to the manufacturer&#x2019;s protocol, and the color change was used to evaluate the protein residue on the instrument surface after a 5-minute incubation period. Green indicated clean, gray indicated mild contamination, light purple indicated moderate contamination, and dark purple indicated severe contamination.</p>
</sec>
<sec id="s2_3_7">
<label>2.3.7</label>
<title>Instrument damage</title>
<p>After cleaning, the instruments were checked for damage, and the number of damaged instruments was recorded.</p>
</sec>
</sec>
<sec id="s2_4">
<label>2.4</label>
<title>Statistical analysis</title>
<p>Statistical analysis was performed using SPSS 26.0 software. Normally distributed data were described using means &#xb1; standard deviation and analyzed using a t-test. Data that did not follow a normal distribution were described using the median and interquartile range [M (Q1-Q3)] and analyzed using the rank sum test. Count data were described using frequency (proportion) and analyzed using the chi-square test. P&lt;0.05 was considered statistically significant.</p>
</sec>
</sec>
<sec id="s3" sec-type="results">
<label>3</label>
<title>Results</title>
<sec id="s3_1">
<label>3.1</label>
<title>Comparison of cleaning time between groups</title>
<p>The cleaning time in the observation group was significantly lower than in the control group, and the difference was statistically significant (P&lt;0.05), as shown in <xref ref-type="table" rid="T1">
<bold>Table&#xa0;1</bold>
</xref> and <xref ref-type="fig" rid="f1">
<bold>Figure&#xa0;1</bold>
</xref>.</p>
<table-wrap id="T1" position="float">
<label>Table&#xa0;1</label>
<caption>
<p>Comparison of cleaning time between groups (mean &#xb1; standard deviation, min).</p>
</caption>
<table frame="hsides">
<thead>
<tr>
<th valign="top" align="left">Group</th>
<th valign="top" align="left">Cleaning time (min)</th>
<th valign="top" align="left">t value</th>
<th valign="top" align="left">P value</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Observation Group (n = 400)</td>
<td valign="top" align="left">67.39 &#xb1; 7.32</td>
<td valign="top" rowspan="2" align="left">26.960</td>
<td valign="top" rowspan="2" align="left">&lt;0.001</td>
</tr>
<tr>
<td valign="top" align="left">Control Group (n = 400)</td>
<td valign="top" align="left">81.24 &#xb1; 7.21</td>
</tr>
</tbody>
</table>
</table-wrap>
<fig id="f1" position="float">
<label>Figure&#xa0;1</label>
<caption>
<p>Comparison of cleaning time between groups. The figure displays the average cleaning time for the observation and control groups. The cleaning time in the observation group (67.39 &#xb1; 7.32 minutes) was significantly shorter than in the control group (81.24 &#xb1; 7.21 minutes), with a statistically significant difference (*P &lt; 0.001).</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fcimb-15-1607905-g001.tif">
<alt-text content-type="machine-generated">Bar chart comparing cleaning time between two groups of 400 individuals each. The observation group has a lower cleaning time, about 65 units, while the control group is approximately 80 units. Asterisk indicates a significant difference.</alt-text>
</graphic>
</fig>
</sec>
<sec id="s3_2">
<label>3.2</label>
<title>Comparison of cleaning effect between groups</title>
<p>There was no statistically significant difference in the cleaning effect between the two groups as assessed by visual inspection, magnifying light source observation, and ATP fluorescence detection (P&gt;0.05). The results are summarized in <xref ref-type="table" rid="T2">
<bold>Table&#xa0;2</bold>
</xref> and <xref ref-type="fig" rid="f2">
<bold>Figure&#xa0;2</bold>
</xref>.</p>
<table-wrap id="T2" position="float">
<label>Table&#xa0;2</label>
<caption>
<p>Comparison of cleaning effect between groups (n, %).</p>
</caption>
<table frame="hsides">
<thead>
<tr>
<th valign="top" rowspan="2" align="left">Group</th>
<th valign="top" colspan="2" align="left">Visual Inspection</th>
<th valign="top" colspan="2" align="left">Magnifying Light Source</th>
<th valign="top" colspan="2" align="left">ATP Fluorescence Detection</th>
</tr>
<tr>
<th valign="top" align="left">Qualified Items</th>
<th valign="top" align="left">Qualification Rate (%)</th>
<th valign="top" align="left">Qualified Items</th>
<th valign="top" align="left">Qualification Rate (%)</th>
<th valign="top" align="left">Qualified Items</th>
<th valign="top" align="left">Qualification Rate (%)</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Observation Group&#xa0;(n = 400)</td>
<td valign="top" align="left">398</td>
<td valign="top" align="left">99.50</td>
<td valign="top" align="left">397</td>
<td valign="top" align="left">99.25</td>
<td valign="top" align="left">398</td>
<td valign="top" align="left">99.50</td>
</tr>
<tr>
<td valign="top" align="left">Control Group&#xa0;(n = 400)</td>
<td valign="top" align="left">392</td>
<td valign="top" align="left">98.00</td>
<td valign="top" align="left">390</td>
<td valign="top" align="left">97.50</td>
<td valign="top" align="left">393</td>
<td valign="top" align="left">98.25</td>
</tr>
<tr>
<td valign="top" align="left">&#x3c7;&#xb2;</td>
<td valign="top" colspan="2" align="left">3.646</td>
<td valign="top" colspan="2" align="left">3.831</td>
<td valign="top" colspan="2" align="left">2.809</td>
</tr>
<tr>
<td valign="top" align="left">P</td>
<td valign="top" colspan="2" align="left">0.056</td>
<td valign="top" colspan="2" align="left">0.050</td>
<td valign="top" colspan="2" align="left">0.094</td>
</tr>
</tbody>
</table>
</table-wrap>
<fig id="f2" position="float">
<label>Figure&#xa0;2</label>
<caption>
<p>Comparison of cleaning effect between groups. This figure compares the cleaning effect between the observation and control groups as assessed by visual inspection, magnifying light source, and ATP fluorescence detection. (ATP: Adenosine Triphosphate). No statistically significant difference was found between the two groups in any of the assessments (P &gt; 0.05). The qualification rates for visual inspection, magnifying light source observation, and ATP fluorescence detection were 99.50%, 99.25%, and 99.50% for the observation group (n = 400) and 98.00%, 97.50%, and 98.25% for the control group (n = 400), respectively.</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fcimb-15-1607905-g002.tif">
<alt-text content-type="machine-generated">Bar chart comparing the cleaning effect between observation and control groups, each with 400 participants. Both groups used three methods: visual method, magnifying glass with light source, and ATP, all showing a 100% effectiveness rate.</alt-text>
</graphic>
</fig>
</sec>
<sec id="s3_3">
<label>3.3</label>
<title>Comparison of protein residue detection between groups</title>
<p>The protein residue level in the observation group was significantly lower than that in the control group, with a statistically significant difference (P&lt;0.05), as shown in <xref ref-type="table" rid="T3">
<bold>Table&#xa0;3</bold>
</xref> and <xref ref-type="fig" rid="f3">
<bold>Figure&#xa0;3</bold>
</xref>.</p>
<table-wrap id="T3" position="float">
<label>Table&#xa0;3</label>
<caption>
<p>Comparison of protein residue detection between groups (n, %).</p>
</caption>
<table frame="hsides">
<thead>
<tr>
<th valign="top" align="center">Group</th>
<th valign="top" align="center">Mild Contamination n (%)</th>
<th valign="top" align="center">Moderate Contamination n (%)</th>
<th valign="top" align="center">Severe Contamination n (%)</th>
<th valign="top" align="center">Clean Items (No Contamination) n (%)</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="center">Observation Group&#xa0;(n = 400)</td>
<td valign="top" align="center">3 (0.75%)</td>
<td valign="top" align="center">2 (0.50%)</td>
<td valign="top" align="center">0</td>
<td valign="top" align="center">395 (98.75%)</td>
</tr>
<tr>
<td valign="top" align="center">Control Group&#xa0;(n = 400)</td>
<td valign="top" align="center">18 (4.50%)</td>
<td valign="top" align="center">9 (2.25%)</td>
<td valign="top" align="center">0</td>
<td valign="top" align="center">373 (93.25%)</td>
</tr>
<tr>
<td valign="top" align="center">&#x3c7;&#xb2; value</td>
<td valign="top" align="center">11.003</td>
<td valign="top" align="center">4.517</td>
<td valign="top" align="center">&#x2013;</td>
<td valign="top" align="center">15.775</td>
</tr>
<tr>
<td valign="top" align="center">P value</td>
<td valign="top" align="center">0.001</td>
<td valign="top" align="center">0.034</td>
<td valign="top" align="center">&#x2013;</td>
<td valign="top" align="center">&lt;0.001</td>
</tr>
</tbody>
</table>
</table-wrap>
<fig id="f3" position="float">
<label>Figure&#xa0;3</label>
<caption>
<p>Comparison of protein residue detection between groups. This figure shows the comparison of protein residue levels between the observation and control groups. The observation group had significantly lower levels of protein contamination, with 98.75% of instruments showing no contamination compared to 93.25% in the control group (n = 400). Statistically significant differences were observed in both mild and moderate contamination rates (*P &lt; 0.05).</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fcimb-15-1607905-g003.tif">
<alt-text content-type="machine-generated">Bar chart comparing two histone residues across observation and control groups, each with 400 participants. Categories include light, moderate, and heavy pollution, and clean conditions. Clean condition bars are significantly higher than those for pollution in both groups. Statistical significance indicated by asterisks (*).</alt-text>
</graphic>
</fig>
</sec>
<sec id="s3_4">
<label>3.4</label>
<title>Comparison of instrument damage between groups</title>
<p>The observation group had a lower instrument damage rate compared to the control group, with a statistically significant difference (P&lt;0.05), as shown in <xref ref-type="table" rid="T4">
<bold>Table&#xa0;4</bold>
</xref> and <xref ref-type="fig" rid="f4">
<bold>Figure&#xa0;4</bold>
</xref>.</p>
<table-wrap id="T4" position="float">
<label>Table&#xa0;4</label>
<caption>
<p>Comparison of instrument damage between groups (n, %).</p>
</caption>
<table frame="hsides">
<thead>
<tr>
<th valign="top" align="center">Group</th>
<th valign="top" align="center">Damaged Instruments</th>
<th valign="top" align="center">Damage Rate (%)</th>
<th valign="top" align="center">&#x3c7;&#xb2; value</th>
<th valign="top" align="center">P value</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="center">Observation Group&#xa0;(n = 400)</td>
<td valign="top" align="center">2</td>
<td valign="top" align="center">0.500</td>
<td valign="top" rowspan="2" align="center">5.415</td>
<td valign="top" rowspan="2" align="center">0.020</td>
</tr>
<tr>
<td valign="top" align="center">Control Group&#xa0;(n = 400)</td>
<td valign="top" align="center">10</td>
<td valign="top" align="center">2.500</td>
</tr>
</tbody>
</table>
</table-wrap>
<fig id="f4" position="float">
<label>Figure&#xa0;4</label>
<caption>
<p>Comparison of instrument damage between groups. This figure compares the instrument damage rates between the observation and control groups. The observation group (n = 400) had a significantly lower instrument damage rate, with fewer instances of damage compared to the control group (n = 400) (P &lt; 0.05).</p>
</caption>
<graphic mimetype="image" mime-subtype="tiff" xlink:href="fcimb-15-1607905-g004.tif">
<alt-text content-type="machine-generated">Bar chart comparing the number of defects between two groups, each with 400 participants. The observation group shows a significantly lower number of defects than the control group.</alt-text>
</graphic>
</fig>
</sec>
<sec id="s3_5">
<label>3.5</label>
<title>Cost-effectiveness analysis</title>
<p>The estimated cost-effectiveness analysis for 400 cleaning cycles revealed a significant economic advantage for the observation group. The total cost for the observation group was $15,984, compared to $21,832 for the control group. This was primarily driven by lower labor costs ($8,984 vs. $10,832) and substantially lower instrument repair costs ($1,000 vs. $5,000). Consequently, the average cost per qualified instrument was 28.1% lower in the observation group ($40.26) than in the control group ($55.98), as detailed in <xref ref-type="table" rid="T5">
<bold>Table&#xa0;5</bold>
</xref>.</p>
<table-wrap id="T5" position="float">
<label>Table&#xa0;5</label>
<caption>
<p>Estimated cost-effectiveness analysis per 400 cleaning cycles.</p>
</caption>
<table frame="hsides">
<thead>
<tr>
<th valign="top" align="center">Cost Parameter</th>
<th valign="top" align="center">Observation Group (n = 400)</th>
<th valign="top" align="center">Control Group (n = 400)</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="center">Labor Costs (at $20/hour)</td>
<td valign="top" align="center">$8,984</td>
<td valign="top" align="center">$10,832</td>
</tr>
<tr>
<td valign="top" align="center">Consumable Costs (est. $15/cycle)</td>
<td valign="top" align="center">$6,000</td>
<td valign="top" align="center">$6,000</td>
</tr>
<tr>
<td valign="top" align="center">Instrument Repair Costs (est. $500/repair)</td>
<td valign="top" align="center">$1,000</td>
<td valign="top" align="center">$5,000</td>
</tr>
<tr>
<td valign="top" align="center">Total Estimated Cost</td>
<td valign="top" align="center">$15,984</td>
<td valign="top" align="center">$21,832</td>
</tr>
<tr>
<td valign="top" align="center">Total Qualified Instruments (Magnifying Light)</td>
<td valign="top" align="center">397</td>
<td valign="top" align="center">390</td>
</tr>
<tr>
<td valign="top" align="center">Cost per Qualified Cycle</td>
<td valign="top" align="center">$40.26</td>
<td valign="top" align="center">$55.98</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
</sec>
<sec id="s4" sec-type="discussion">
<label>4</label>
<title>Discussion</title>
<p>Hospital infection management guidelines (<xref ref-type="bibr" rid="B1">Central sterile supply department (CSSD) - part 3: surveillance standard for cleaning, disinfection and sterilization WS310.3-2016, 2017</xref>) indicate that rigid endoscope instruments must be thoroughly cleaned and sterilized after use. If the instruments are not cleaned properly and residual organic material remains, it may obstruct the penetration of sterilizing agents during the disinfection process, resulting in inadequate sterilization. Therefore, cleaning is a prerequisite for the disinfection and sterilization of instruments. Additionally, for some rigid endoscope instruments with complex structures and intricate designs, blood clots, tissue fragments, and other debris are more likely to remain in the hard-to-reach crevices of the instrument, potentially fostering bacterial or spore formation, which ultimately negatively affects the disinfection and sterilization effectiveness (<xref ref-type="bibr" rid="B4">Baboudjian et&#xa0;al., 2023</xref>; <xref ref-type="bibr" rid="B22">Mora-Galv&#xe1;n et&#xa0;al., 2024</xref>). Rutala et&#xa0;al (<xref ref-type="bibr" rid="B32">Valverde-L&#xf3;pez et&#xa0;al., 2021</xref>). pointed out that when used properly, disinfection and sterilization can ensure the safe use of both invasive and non-invasive medical devices. Cleaning should always precede high-level disinfection and sterilization. Strict adherence to current disinfection and sterilization guidelines is critical in preventing patient infections and exposure to infectious pathogens. Relevant studies (<xref ref-type="bibr" rid="B34">Vincenti et&#xa0;al., 2021</xref>; <xref ref-type="bibr" rid="B11">Eussen et&#xa0;al., 2024</xref>) have shown that the cleaning effectiveness of rigid endoscopes is influenced by several factors, such as the complexity of the instrument&#x2019;s structure, the degree of contamination, and the cleaning method. Among these, the cleaning method directly impacts the final cleanliness of the instrument, making it essential to improve cleaning methods to enhance cleaning quality. Currently, clinical sterilization supply departments primarily use cleaning machines for instrument cleaning, which can fully meet the cleanliness requirements of the instruments and help prolong their service life. In recent years, ultrasonic cleaning machines have been widely used in clinical sterilization supply departments, with spraying head flushing technology as the main approach (<xref ref-type="bibr" rid="B13">Hofmann et&#xa0;al., 2023</xref>; <xref ref-type="bibr" rid="B37">Zhang et&#xa0;al., 2023</xref>). However, during the actual cleaning process of rigid endoscope instruments, it is necessary to constantly adjust the cleaning nozzles, and the instruments cannot be directly placed in the cleaning tray, which complicates the cleaning procedure (<xref ref-type="bibr" rid="B19">Liu et&#xa0;al., 2023</xref>).</p>
<p>The pulsed vacuum cleaning and disinfection machine is a more efficient cleaning and disinfection device suitable for cleaning various medical instruments, such as general clinical instruments, minimally invasive instruments, and dental surgical instruments. The pulsed vacuum cleaning and disinfection machine combines vacuum pulses with ultrasonic disinfection to achieve the cleaning purpose. It transforms the traditional manual cleaning process, which involves classifying and separating instruments, into an integrated cleaning and disinfection system. This system can automatically complete the full process of pulsed vacuum cleaning, ultrasonic cleaning, thermal disinfection, and vacuum drying (<xref ref-type="bibr" rid="B19">Liu et&#xa0;al., 2023</xref>). Liu et&#xa0;al (<xref ref-type="bibr" rid="B19">Liu et&#xa0;al., 2023</xref>). pointed out that the pulsed vacuum cleaning and disinfection machine can effectively improve the cleaning quality of dental instruments and reduce cleaning time. Therefore, it should be widely applied and promoted in clinical settings. The results of this study show that the cleaning time in the observation group was significantly shorter than in the control group (P &lt; 0.05), indicating that the pulsed vacuum cleaning and disinfection machine can reduce the cleaning time for rigid endoscope instruments. This may be because the application of the pulsed vacuum cleaning and disinfection machine in sterilization supply departments helps shorten the cleaning time, saving manpower and resources, thus improving the instrument turnover efficiency. The nozzles and hose connections in ultrasonic cleaners are prone to contamination and need regular cleaning, which increases the workload of staff and prolongs the cleaning time (<xref ref-type="bibr" rid="B38">Zhou et&#xa0;al., 2020</xref>). In contrast, the pulsed vacuum cleaning and disinfection machine does not have strict limitations regarding the loading method and type of instruments, allowing for a larger loading capacity and greatly shortening cleaning time, thereby improving cleaning efficiency while maintaining cleaning quality (<xref ref-type="bibr" rid="B38">Zhou et&#xa0;al., 2020</xref>).</p>
<p>In a study by Zhou et&#xa0;al (<xref ref-type="bibr" rid="B38">Zhou et&#xa0;al., 2020</xref>), the pulsed vacuum cleaning and disinfection machine was observed for its effectiveness in cleaning endoscope instruments. Group B, using the pulsed vacuum machine, was compared with Group A, which used an ultrasonic cleaner. The results showed that Group B had a higher cleaning degree and a higher negative rate of Jelly contamination, as well as a lower ATP fluorescence positive rate than the control group (P &lt; 0.05). The findings of this study also revealed that there was no significant difference between the two groups in terms of visual inspection, magnifying light source, and ATP fluorescence (P &gt; 0.05), suggesting that the use of the pulsed vacuum cleaning and disinfection machine on rigid endoscope instruments achieved comparable results to ultrasonic cleaning, consistent with previous studies. This further indicates that the pulsed vacuum cleaning and disinfection machine, when applied in sterilization supply departments for cleaning rigid endoscope instruments, outperforms the ultrasonic cleaner and significantly improves cleaning quality.</p>
<p>The reasons for this can be explained by the pulsed vacuum cleaning and disinfection machine&#x2019;s design, which includes an automatic walking unit around the outer frame. This design allows the cleaning machine to travel smoothly through internal pipes, enabling rapid cleaning even in deep and curved areas of the instrument. The pulsed water vapor can directly spray into these areas, maximizing the cleaning effect. Additionally, the machine can perform vacuum degassing treatment, which causes the tiny bubbles in the cleaning liquid to expand rapidly as the pressure decreases. This enhances the scrubbing force on the instrument&#x2019;s surface and accelerates the loosening and removal of biofilms, ultimately improving surface cleanliness (<xref ref-type="bibr" rid="B37">Zhang et&#xa0;al., 2023</xref>).</p>
<p>Secker et&#xa0;al (<xref ref-type="bibr" rid="B31">Secker et&#xa0;al., 2020</xref>). highlighted that an effective cleaning method could eliminate residual proteins and amyloid protein contaminants, potentially reducing hospital-acquired infections. Yao et&#xa0;al (<xref ref-type="bibr" rid="B38">Zhou et&#xa0;al., 2020</xref>). also noted that the pulsed vacuum cleaning and disinfection machine&#x2019;s application in endoscope cleaning had more significant effects, shortening cleaning time, improving efficiency, reducing Jelly negative rate, ATP fluorescence positive rate, and RLU values, and decreasing protein residue. The results of this study also showed that the observation group had a higher cleaning rate than the control group (P &gt; 0.05), suggesting that the pulsed vacuum cleaning and disinfection machine can improve the cleaning rate of rigid endoscope instruments and reduce protein residue. This may be because the pulsed cleaning and disinfection machine uses a new drying technology that combines jacket-structured vacuum drying with hot air drying, allowing instruments to avoid secondary drying and saving drying time. The working principle and loading basket design of the pulsed cleaning and disinfection machine also enable more instruments to be cleaned and disinfected in a shorter period.</p>
<p>Zhou et&#xa0;al (<xref ref-type="bibr" rid="B38">Zhou et&#xa0;al., 2020</xref>). found that the pulsed vacuum cleaning and disinfection machine is effective in cleaning endoscope instruments, reducing cleaning time without increasing instrument damage rate, and thus it is worth promoting in clinical applications. The results of this study showed that the instrument damage rate in the observation group was significantly lower than that in the control group (P &lt; 0.05), indicating that the pulsed vacuum cleaning and disinfection machine can reduce the damage rate of rigid endoscope instruments. When operating, the pulsed vacuum cleaning machine can precisely control pressure changes. During the vacuum phase, the air is gradually extracted from the chamber, preventing sudden pressure changes that could cause strong suction and damage to the instruments. During the injection of cleaning liquids and steam, the pressure increases steadily and stays within the safe range for the instruments, preventing damage from excessive pressure. Furthermore, the machine can accurately regulate the temperature, typically maintaining it between 50&#xb0;C and 90&#xb0;C during cleaning and disinfection. This temperature range is effective for cleaning while being lower than the thermal deformation temperature of materials such as metals and plastics used in rigid endoscopes, ensuring that the instruments will not deform or be damaged by excessive heat.</p>
<sec id="s4_1">
<label>4.1</label>
<title>Perspectives for clinical practice and future directions</title>
<p>The findings of this study have significant implications for clinical practice, particularly concerning patient safety and operational efficiency. The adoption of advanced cleaning technologies like the pulsed vacuum washer-disinfector is not merely a technological upgrade but also a catalyst for evolving professional roles and practices within the hospital. The successful implementation of such systems requires a highly skilled workforce. Clinical Nurse Specialists (CNS), for example, can play a pivotal role in overseeing the quality management of instrument reprocessing, developing evidence-based protocols, and providing advanced training to staff, thereby enhancing safety in the operating theater and sterilization department (<xref ref-type="bibr" rid="B23">Nilsen et&#xa0;al., 2020</xref>). Furthermore, the complexity of modern surgical instruments demands continuous education and competency validation for all personnel involved. Knowledge and adherence to best practices by operating room and sterilization supply department nurses are fundamental to preventing an effective reprocessing cycle, as deviations can directly contribute to surgical site infections (<xref ref-type="bibr" rid="B12">Heibeyn et&#xa0;al., 2021</xref>). However, achieving seamless integration and collaboration between these departments is often challenging. Overcoming barriers such as communication gaps and differing departmental priorities&#x2014;rooted in organizational fragmentation&#x2014;is essential for effective interprofessional teamwork, which is a cornerstone of patient safety in the surgical environment, as systematic assessments reveal that these issues, including hierarchical conflicts and resource-related tensions, significantly increase the risk of surgical complications and require multi-level interventions addressing individual, team, and systems factors to ensure sustainable improvements in teamwork and safety outcomes (<xref ref-type="bibr" rid="B10">Etherington et&#xa0;al., 2021</xref>; <xref ref-type="bibr" rid="B33">van Dalen et&#xa0;al., 2022</xref>). Moreover, the COVID-19 pandemic reinforced the critical importance of impeccable infection control, highlighting the risks associated with aerosol-generating procedures and placing an even greater emphasis on stringent reprocessing protocols to prevent nosocomial transmission (<xref ref-type="bibr" rid="B27">Repici et&#xa0;al., 2020</xref>). Future research should focus on the long-term impact of these advanced cleaning systems on instrument longevity, the incidence of surgical site infections, and cost-effectiveness analyses. Additionally, studies exploring the development of standardized educational programs and teamwork-building interventions for reprocessing staff would be highly valuable.</p>
</sec>
</sec>
<sec id="s5">
<label>5</label>
<title>Limitations</title>
<p>This study has several limitations that should be acknowledged. First, this was a single-center study, which may limit the generalizability of our findings to other healthcare settings with different patient populations, surgical caseloads, or institutional protocols. Second, our assessment of cleaning efficacy focused on physical and chemical indicators (visual inspection, ATP, protein residue) rather than microbiological analysis. While these are standard methods, future studies should integrate microbial cultures (e.g., biofilm PCR assays). Third, as acknowledged by the addition of our preliminary cost-effectiveness data, a more formal and comprehensive economic evaluation is needed to fully assess the financial viability for healthcare institutions with varying capital budgets. Finally, while we monitored for instrument damage, a longer-term follow-up would be beneficial to assess the cumulative impact of each cleaning method on the lifespan of the instruments.</p>
</sec>
<sec id="s6" sec-type="conclusions">
<label>6</label>
<title>Conclusion</title>
<p>In conclusion, the pulsed vacuum cleaning and disinfection machine demonstrates superior performance compared to the traditional ultrasonic cleaner for reprocessing rigid endoscopic instruments. It significantly reduces cleaning time, lowers the risk of instrument damage, and is more effective at removing protein residues, all of which contribute to higher operational efficiency and enhanced patient safety. Our preliminary economic analysis suggests these operational gains also translate into significant cost savings, reinforcing the device&#x2019;s value proposition. While the initial investment may be higher, the long-term benefits in terms of faster instrument turnover and improved cleaning quality make it a highly valuable technology for modern sterilization supply centers. However, to fully leverage the benefits of such advanced systems, healthcare institutions must also invest in robust staff training, foster a culture of interprofessional collaboration, and support the advanced roles of nursing professionals in quality management. The pulsed vacuum cleaning and disinfection machine is highly recommended for clinical promotion as a key component of a comprehensive strategy to ensure the highest standards of instrument decontamination.</p>
</sec>
</body>
<back>
<sec id="s7" sec-type="data-availability">
<title>Data availability statement</title>
<p>The original contributions presented in the study are included in the article/<xref ref-type="supplementary-material" rid="SM1">
<bold>Supplementary Material</bold>
</xref>. Further inquiries can be directed to the corresponding author.</p>
</sec>
<sec id="s8" sec-type="ethics-statement">
<title>Ethics statement</title>
<p>The study protocol was approved by the Ethics Committee of Shijiazhuang Maternal and Child Health Hospital, and the study was performed in accordance with the Helsinki II declaration. Informed consent was obtained from all the study subjects before enrollment.</p>
</sec>
<sec id="s9" sec-type="author-contributions">
<title>Author contributions</title>
<p>LB: Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Writing &#x2013; original draft. XW: Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Supervision, Writing &#x2013; original draft, Writing &#x2013; review &amp; editing. JL: Formal analysis, Investigation, Methodology, Writing &#x2013; original draft. YH: Data curation, Formal analysis, Investigation, Methodology, Writing &#x2013; review &amp; editing.</p>
</sec>
<sec id="s10" sec-type="funding-information">
<title>Funding</title>
<p>The author(s) declare financial support was received for the research and/or publication of this article. This study was supported by Medical Science Research Project of Hebei (Project Number: 20241956).</p>
</sec>
<sec id="s11" sec-type="COI-statement">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec id="s12" sec-type="ai-statement">
<title>Generative AI statement</title>
<p>The author(s) declare that no Generative AI was used in the creation of this manuscript.</p>
</sec>
<sec id="s13" sec-type="disclaimer">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<sec id="s14" sec-type="supplementary-material">
<title>Supplementary material</title>
<p>The Supplementary Material for this article can be found online at: <ext-link ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/fcimb.2025.1607905/full#supplementary-material">https://www.frontiersin.org/articles/10.3389/fcimb.2025.1607905/full#supplementary-material</ext-link>
</p>
<supplementary-material xlink:href="DataSheet1.docx" id="SM1" mimetype="application/vnd.openxmlformats-officedocument.wordprocessingml.document"/>
</sec>
<ref-list>
<title>References</title>
<ref id="B1">
<citation citation-type="journal">(<year>2017</year>). <article-title>Central sterile supply department (CSSD) - part 3: surveillance standard for cleaning, disinfection and sterilization WS310.3-2016</article-title>. <source>China Infection Control J.</source> <volume>16</volume>, <fpage>1095</fpage>&#x2013;<lpage>1100</lpage>. Available online at: <uri xlink:href="https://www.codeofchina.com/standard/WS310.3-2016.html"> https://www.codeofchina.com/standard/WS310.3-2016.html</uri>
</citation></ref>
<ref id="B2">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Al Mayahi</surname> <given-names>Z.</given-names>
</name>
<name>
<surname>Kamel</surname> <given-names>S.</given-names>
</name>
<name>
<surname>Amer</surname> <given-names>H.</given-names>
</name>
<name>
<surname>Beatty</surname> <given-names>M.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Outbreak of colistin-resistant organisms at a tertiary hospital in Riyadh, Saudi Arabia, 2016</article-title>. <source>Pan Afr. Med. J.</source> <volume>34</volume>, <fpage>162</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.11604/pamj.2019.34.162.19998</pub-id>, PMID: <pub-id pub-id-type="pmid">32153702</pub-id></citation></ref>
<ref id="B3">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Anderson</surname> <given-names>K.</given-names>
</name>
<name>
<surname>Drosnock</surname> <given-names>M. A.</given-names>
</name>
<name>
<surname>Kovach</surname> <given-names>S. M.</given-names>
</name>
<name>
<surname>Zitek</surname> <given-names>T.</given-names>
</name>
</person-group> (<year>2023</year>). <article-title>Performance qualification testing improves processing of lumened surgical instruments in ultrasonic cleaners</article-title>. <source>AORN J.</source> <volume>118</volume>, <fpage>79</fpage>&#x2013;<lpage>86</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/aorn.13967</pub-id>, PMID: <pub-id pub-id-type="pmid">37493426</pub-id></citation></ref>
<ref id="B4">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Baboudjian</surname> <given-names>M.</given-names>
</name>
<name>
<surname>Pradere</surname> <given-names>B.</given-names>
</name>
<name>
<surname>Uleri</surname> <given-names>A.</given-names>
</name>
<name>
<surname>Lechevallier</surname> <given-names>E.</given-names>
</name>
</person-group> (<year>2023</year>). <article-title>Reuse and reprocessing of endoscopic instruments: con</article-title>. <source>Eur. Urol. Focus</source> <volume>9</volume>, <fpage>859</fpage>&#x2013;<lpage>860</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.euf.2023.09.010</pub-id>, PMID: <pub-id pub-id-type="pmid">37748949</pub-id></citation></ref>
<ref id="B5">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Benowitz</surname> <given-names>I.</given-names>
</name>
<name>
<surname>Moulton-Meissner</surname> <given-names>H. A.</given-names>
</name>
<name>
<surname>Epstein</surname> <given-names>L.</given-names>
</name>
<name>
<surname>Arduino</surname> <given-names>M. J.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>The centers for disease control and prevention guidance on flexible gastrointestinal endoscopes: lessons learned from outbreaks, infection control</article-title>. <source>Gastrointestinal endoscopy Clinics North America</source> <volume>30</volume>, <fpage>723</fpage>&#x2013;<lpage>733</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.giec.2020.06.009</pub-id>, PMID: <pub-id pub-id-type="pmid">32891228</pub-id></citation></ref>
<ref id="B6">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Casini</surname> <given-names>B.</given-names>
</name>
<name>
<surname>Spagnolo</surname> <given-names>A. M.</given-names>
</name>
<name>
<surname>Sartini</surname> <given-names>M.</given-names>
</name>
<name>
<surname>Tuvo</surname> <given-names>B.</given-names>
</name>
<name>
<surname>Scarpaci</surname> <given-names>M.</given-names>
</name>
<name>
<surname>Barchitta</surname> <given-names>M.</given-names>
</name>
<etal/>
</person-group>. (<year>2023</year>). <article-title>Microbiological surveillance post-reprocessing of flexible endoscopes used in digestive endoscopy: a national study</article-title>. <source>J. Hosp. infection</source> <volume>131</volume>, <fpage>139</fpage>&#x2013;<lpage>147</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.jhin.2022.09.024</pub-id>, PMID: <pub-id pub-id-type="pmid">36244520</pub-id></citation></ref>
<ref id="B7">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Chang</surname> <given-names>C.</given-names>
</name>
<name>
<surname>Tao</surname> <given-names>P.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>High-Efficiency Superheated Steam Generation for Porta ble Sterilization under Ambient Pressure and Low Solar Flux</article-title>. <source>ACS Appl. materials interfaces</source> <volume>11</volume>, <fpage>18466</fpage>&#x2013;<lpage>18474</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1021/acsami.9b04535</pub-id>, PMID: <pub-id pub-id-type="pmid">31046219</pub-id></citation></ref>
<ref id="B8">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Choi</surname> <given-names>J.</given-names>
</name>
<name>
<surname>Lee</surname> <given-names>M.</given-names>
</name>
<name>
<surname>Lee</surname> <given-names>Y.</given-names>
</name>
<name>
<surname>Song</surname> <given-names>Y.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Effectiveness of plasma-treated hydrogen peroxide mist disinfection in various hospital environments</article-title>. <source>Int. J. Environ. Res. Public Health</source> <volume>18</volume>(<issue>18</issue>):<fpage>9841</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.3390/ijerph18189841</pub-id>, PMID: <pub-id pub-id-type="pmid">34574763</pub-id></citation></ref>
<ref id="B9">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Des Jarlais</surname> <given-names>D. C.</given-names>
</name>
<name>
<surname>Lyles</surname> <given-names>C.</given-names>
</name>
<name>
<surname>Crepaz</surname> <given-names>N.</given-names>
</name>
</person-group> (<year>2004</year>). <article-title>Improving the reporting quality of nonrandomized evaluations of behavioral and public health interventions: the TREND statement</article-title>. <source>Am. J. Public Health</source> <volume>94</volume>, <fpage>361</fpage>&#x2013;<lpage>366</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.2105/AJPH.94.3.361</pub-id>, PMID: <pub-id pub-id-type="pmid">14998794</pub-id></citation></ref>
<ref id="B10">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Etherington</surname> <given-names>C.</given-names>
</name>
<name>
<surname>Burns</surname> <given-names>J. K.</given-names>
</name>
<name>
<surname>Kitto</surname> <given-names>S.</given-names>
</name>
<name>
<surname>Brehaut</surname> <given-names>J. C.</given-names>
</name>
<name>
<surname>Britton</surname> <given-names>M.</given-names>
</name>
<name>
<surname>Singh</surname> <given-names>S.</given-names>
</name>
<etal/>
</person-group>. (<year>2021</year>). <article-title>Barriers and enablers to effective interprofessional teamwork in the operating room: A qualitative study using the Theoretical Domains Framework</article-title>. <source>PloS One</source> <volume>16</volume>, <fpage>e0249576</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1371/journal.pone.0249576</pub-id>, PMID: <pub-id pub-id-type="pmid">33886580</pub-id></citation></ref>
<ref id="B11">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Eussen</surname> <given-names>M. M. M.</given-names>
</name>
<name>
<surname>Moossdorff</surname> <given-names>M.</given-names>
</name>
<name>
<surname>Wellens</surname> <given-names>L. M.</given-names>
</name>
<name>
<surname>de Reuver</surname> <given-names>P. R.</given-names>
</name>
<name>
<surname>Stobernack</surname> <given-names>T.</given-names>
</name>
<name>
<surname>Bijlmakers</surname> <given-names>L.</given-names>
</name>
<etal/>
</person-group>. (<year>2024</year>). <article-title>Beyond single-use: a systematic review of environmental, economic, and clinical impacts of endoscopic surgical instrumentation</article-title>. <source>Int. J. Surg. (London England)</source> <volume>110</volume>, <fpage>8136</fpage>&#x2013;<lpage>8150</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1097/JS9.0000000000002141</pub-id>, PMID: <pub-id pub-id-type="pmid">39806751</pub-id></citation></ref>
<ref id="B12">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Heibeyn</surname> <given-names>J.</given-names>
</name>
<name>
<surname>Knig</surname> <given-names>N.</given-names>
</name>
<name>
<surname>Domnik</surname> <given-names>N.</given-names>
</name>
<name>
<surname>Schweizer</surname> <given-names>M.</given-names>
</name>
<name>
<surname>Radermacher</surname> <given-names>K.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Design and evaluation of a novel instrument gripper for handling of surgical instruments</article-title>. <source>Curr. Dir. Biomed. Eng.</source> <volume>7</volume>, <fpage>1</fpage>&#x2013;<lpage>5</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1515/cdbme-2021-1001</pub-id>
</citation></ref>
<ref id="B13">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hofmann</surname> <given-names>P.</given-names>
</name>
<name>
<surname>Kunz</surname> <given-names>A.</given-names>
</name>
<name>
<surname>Schmidt</surname> <given-names>F.</given-names>
</name>
<name>
<surname>Beuer</surname> <given-names>F.</given-names>
</name>
<name>
<surname>Duddeck</surname> <given-names>D.</given-names>
</name>
</person-group> (<year>2023</year>). <article-title>Influence of exposure of customized dental implant abutments to different cleaning procedures: an <italic>in vitro</italic> study using AI-assisted SEM/EDS analysis</article-title>. <source>Int. J. implant dentistry</source> <volume>9</volume>, <fpage>33</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1186/s40729-023-00498-8</pub-id>, PMID: <pub-id pub-id-type="pmid">37730937</pub-id></citation></ref>
<ref id="B14">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hu</surname> <given-names>R.</given-names>
</name>
<name>
<surname>Chen</surname> <given-names>Y.</given-names>
</name>
<name>
<surname>Hu</surname> <given-names>T.</given-names>
</name>
<name>
<surname>Yi</surname> <given-names>L.</given-names>
</name>
</person-group> (<year>2023</year>). <article-title>The effects of health belief model-based intervention on nurses&#x2019; sterilizing practices when moistening surgical instruments</article-title>. <source>Cirugia y cirujanos</source> <volume>91</volume>, <fpage>501</fpage>&#x2013;<lpage>506</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.24875/CIRU.22000386</pub-id>, PMID: <pub-id pub-id-type="pmid">37677945</pub-id></citation></ref>
<ref id="B15">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hu</surname> <given-names>T.</given-names>
</name>
<name>
<surname>Yi</surname> <given-names>L.</given-names>
</name>
<name>
<surname>Tang</surname> <given-names>Y.</given-names>
</name>
<name>
<surname>Chen</surname> <given-names>Y.</given-names>
</name>
<name>
<surname>Hu</surname> <given-names>R.</given-names>
</name>
</person-group> (<year>2023</year>). <article-title>Enhancing nighttime surgical instrument cleaning efficiency: an ECRS-based approach</article-title>. <source>Med. Sci. monitor: Int. Med. J. Exp. Clin. Res.</source> <volume>29</volume>, <elocation-id>e940346</elocation-id>. doi:&#xa0;<pub-id pub-id-type="doi">10.12659/MSM.940346</pub-id>, PMID: <pub-id pub-id-type="pmid">37482678</pub-id></citation></ref>
<ref id="B16">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hu</surname> <given-names>Z.</given-names>
</name>
<name>
<surname>Zhou</surname> <given-names>L.</given-names>
</name>
<name>
<surname>Tao</surname> <given-names>X.</given-names>
</name>
<name>
<surname>Li</surname> <given-names>P.</given-names>
</name>
<name>
<surname>Zheng</surname> <given-names>X.</given-names>
</name>
<name>
<surname>Zhang</surname> <given-names>W.</given-names>
</name>
<etal/>
</person-group>. (<year>2024</year>). <article-title>Antimicrobial resistance survey and whole-genome analysis of nosocomial P</article-title>. <source>Aeruginosa isolated eastern Province China 2016-2021. Ann. Clin. Microbiol. antimicrobials</source> <volume>23</volume>, <fpage>12</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1186/s12941-023-00656-1</pub-id>, PMID: <pub-id pub-id-type="pmid">38336730</pub-id></citation></ref>
<ref id="B17">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kwakman</surname> <given-names>J. A.</given-names>
</name>
<name>
<surname>Vos</surname> <given-names>M. C.</given-names>
</name>
<name>
<surname>Bruno</surname> <given-names>M. J.</given-names>
</name>
</person-group> (<year>2023</year>). <article-title>Investigation of the efficacy of an innovative endoscope drying and storage method in a simulated ERCP setting</article-title>. <source>Endoscopy Int. Open</source> <volume>11</volume>, <fpage>E419</fpage>&#x2013;<lpage>e425</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1055/a-2017-3872</pub-id>, PMID: <pub-id pub-id-type="pmid">37124714</pub-id></citation></ref>
<ref id="B18">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Liu</surname> <given-names>F.</given-names>
</name>
<name>
<surname>Teng</surname> <given-names>Z.</given-names>
</name>
<name>
<surname>Shan</surname> <given-names>Y.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Application and effectiveness of Plan-Do-Check-Action cycle method for quality control in rigid container handling</article-title>. <source>Int. J. Clin. Exp. Med</source>. <volume>14</volume>(<issue>2</issue>):<page-range>1258&#x2013;1263</page-range>.</citation></ref>
<ref id="B19">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Liu</surname> <given-names>M.</given-names>
</name>
<name>
<surname>Xie</surname> <given-names>W.</given-names>
</name>
<name>
<surname>Song</surname> <given-names>S.</given-names>
</name>
<name>
<surname>Wang</surname> <given-names>Y.</given-names>
</name>
<name>
<surname>Lu</surname> <given-names>Z.</given-names>
</name>
</person-group> (<year>2023</year>). <article-title>Effect of pulsating vacuum cleaning sterilizer on the cleaning quality of dental handpieces</article-title>. <source>Sichuan da xue xue bao Yi xue ban = J. Sichuan Univ. Med. Sci. edition</source> <volume>54</volume>, <fpage>788</fpage>&#x2013;<lpage>791</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.12182/20230760201</pub-id>, PMID: <pub-id pub-id-type="pmid">37545075</pub-id></citation></ref>
<ref id="B20">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lowe</surname> <given-names>G.</given-names>
</name>
<name>
<surname>Plummer</surname> <given-names>V.</given-names>
</name>
<name>
<surname>O&#x2019;Brien</surname> <given-names>A. P.</given-names>
</name>
<name>
<surname>Boyd</surname> <given-names>L.</given-names>
</name>
</person-group> (<year>2012</year>). <article-title>Time to clarify&#x2013;the value of advanced practice nursing roles in health care</article-title>. <source>J. advanced Nurs.</source> <volume>68</volume>, <fpage>677</fpage>&#x2013;<lpage>685</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1111/j.1365-2648.2011.05790.x</pub-id>, PMID: <pub-id pub-id-type="pmid">21790738</pub-id></citation></ref>
<ref id="B21">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mirzaei</surname> <given-names>R.</given-names>
</name>
<name>
<surname>Mohammadzadeh</surname> <given-names>R.</given-names>
</name>
<name>
<surname>Alikhani</surname> <given-names>M. Y.</given-names>
</name>
<name>
<surname>Shokri Moghadam</surname> <given-names>M.</given-names>
</name>
<name>
<surname>Karampoor</surname> <given-names>S.</given-names>
</name>
<name>
<surname>Kazemi</surname> <given-names>S.</given-names>
</name>
<etal/>
</person-group>. (<year>2020</year>). <article-title>The biofilm-associated bacterial infections unrelated to indwelling devices</article-title>. <source>IUBMB Life</source> <volume>72</volume>, <fpage>1271</fpage>&#x2013;<lpage>1285</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1002/iub.2266</pub-id>, PMID: <pub-id pub-id-type="pmid">32150327</pub-id></citation></ref>
<ref id="B22">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mora-Galv&#xe1;n</surname> <given-names>J. A.</given-names>
</name>
<name>
<surname>Escobar-Ponce</surname> <given-names>L. F.</given-names>
</name>
<name>
<surname>Olgu&#xed;n-Ortega</surname> <given-names>A.</given-names>
</name>
<name>
<surname>Villeda-Gabriel</surname> <given-names>G.</given-names>
</name>
<name>
<surname>Figueroa-Dami&#xe1;n</surname> <given-names>R.</given-names>
</name>
<name>
<surname>Rend&#xf3;n-Molina</surname> <given-names>A.</given-names>
</name>
</person-group> (<year>2024</year>). <article-title>Assessment of ultraviolet-C light for sterilization of hysteroscopy instruments</article-title>. <source>Cureus</source> <volume>16</volume>, <elocation-id>e73609</elocation-id>. doi:&#xa0;<pub-id pub-id-type="doi">10.7759/cureus.73609</pub-id>, PMID: <pub-id pub-id-type="pmid">39677219</pub-id></citation></ref>
<ref id="B23">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Nilsen</surname> <given-names>P.</given-names>
</name>
<name>
<surname>Seing</surname> <given-names>I.</given-names>
</name>
<name>
<surname>Ericsson</surname> <given-names>C.</given-names>
</name>
<name>
<surname>Birken</surname> <given-names>S. A.</given-names>
</name>
<name>
<surname>Schildmeijer</surname> <given-names>K.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Characteristics of successful changes in health care organizations: an interview study with physicians, registered nurses and assistant nurses</article-title>. <source>BMC Health Serv. Res.</source> <volume>20</volume>, <fpage>147</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1186/s12913-020-4999-8</pub-id>, PMID: <pub-id pub-id-type="pmid">32106847</pub-id></citation></ref>
<ref id="B24">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ofstead</surname> <given-names>C. L.</given-names>
</name>
<name>
<surname>Hopkins</surname> <given-names>K. M.</given-names>
</name>
<name>
<surname>Smart</surname> <given-names>A. G.</given-names>
</name>
<name>
<surname>Eiland</surname> <given-names>J. E.</given-names>
</name>
<name>
<surname>Wetzler</surname> <given-names>H. P.</given-names>
</name>
<name>
<surname>Bechis</surname> <given-names>S. K.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Reprocessing effectiveness for flexible ureteroscopes: A critical look at the evidence</article-title>. <source>Urology</source> <volume>164</volume>, <fpage>25</fpage>&#x2013;<lpage>32</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.urology.2022.01.033</pub-id>, PMID: <pub-id pub-id-type="pmid">35123986</pub-id></citation></ref>
<ref id="B25">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pereira</surname> <given-names>S. S.</given-names>
</name>
<name>
<surname>Oliveira</surname> <given-names>H. M.</given-names>
</name>
<name>
<surname>Turrini</surname> <given-names>R. N.</given-names>
</name>
<name>
<surname>Lacerda</surname> <given-names>R. A.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>Disinfection with sodium hypochlorite in hospital environmental surfaces in the reduction of contamination and infection prevention: a systematic review</article-title>. <source>Rev. da Escola Enfermagem da U S P</source> <volume>49</volume>, <fpage>681</fpage>&#x2013;<lpage>688</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1590/S0080-623420150000400020</pub-id>, PMID: <pub-id pub-id-type="pmid">26353107</pub-id></citation></ref>
<ref id="B26">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Protano</surname> <given-names>C.</given-names>
</name>
<name>
<surname>Cammalleri</surname> <given-names>V.</given-names>
</name>
<name>
<surname>Romano Spica</surname> <given-names>V.</given-names>
</name>
<name>
<surname>Valeriani</surname> <given-names>F.</given-names>
</name>
<name>
<surname>Vitali</surname> <given-names>M.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Hospital environment as a reservoir for cross transmission: cleaning and disinfection procedures</article-title>. <source>Annali di igiene: medicina preventiva e di comunita</source> <volume>31</volume>, <fpage>436</fpage>&#x2013;<lpage>448</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.7416/ai.2019.2305</pub-id>, PMID: <pub-id pub-id-type="pmid">31304524</pub-id></citation></ref>
<ref id="B27">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Repici</surname> <given-names>A.</given-names>
</name>
<name>
<surname>Maselli</surname> <given-names>R.</given-names>
</name>
<name>
<surname>Colombo</surname> <given-names>M.</given-names>
</name>
<name>
<surname>Gabbiadini</surname> <given-names>R.</given-names>
</name>
<name>
<surname>Spadaccini</surname> <given-names>M.</given-names>
</name>
<name>
<surname>Anderloni</surname> <given-names>A.</given-names>
</name>
<etal/>
</person-group>. (<year>2020</year>). <article-title>Galtieri PA et&#xa0;al: Coronavirus (COVID-19) outbreak: what the department of endoscopy should know</article-title>. <source>Gastrointestinal endoscopy</source> <volume>92</volume>, <fpage>192</fpage>&#x2013;<lpage>197</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.gie.2020.03.019</pub-id>, PMID: <pub-id pub-id-type="pmid">32179106</pub-id></citation></ref>
<ref id="B28">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rotello</surname> <given-names>V. M.</given-names>
</name>
</person-group> (<year>2023</year>). <article-title>Nanomaterials for fighting multidrug-resistant biofilm infections</article-title>. <source>BME Front.</source> <volume>4</volume>, <fpage>0017</fpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.34133/bmef.0017</pub-id>, PMID: <pub-id pub-id-type="pmid">37849666</pub-id></citation></ref>
<ref id="B29">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rutala</surname> <given-names>W. A.</given-names>
</name>
<name>
<surname>Weber</surname> <given-names>D. J.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Outbreaks of carbapenem-resistant Enterobacteriaceae infections associated with duodenoscopes: What can we do to prevent infections</article-title>? <source>Am. J. Infect. Control</source> <volume>44</volume>, <fpage>e47</fpage>&#x2013;<lpage>e51</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.ajic.2015.10.037</pub-id>, PMID: <pub-id pub-id-type="pmid">27131135</pub-id></citation></ref>
<ref id="B30">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Scholz</surname> <given-names>P. M.</given-names>
</name>
<name>
<surname>Kirstein</surname> <given-names>M. M.</given-names>
</name>
<name>
<surname>Solbach</surname> <given-names>P. C.</given-names>
</name>
<name>
<surname>Vonberg</surname> <given-names>R. P.</given-names>
</name>
</person-group> (<year>2023</year>). <article-title>A systematic analysis of nosocomial outbreaks of nosocomial infections after gastrointestinal endoscopy</article-title>. <source>Z. fur Gastroenterologie</source> <volume>61</volume>, <fpage>536</fpage>&#x2013;<lpage>543</lpage>., PMID: <pub-id pub-id-type="pmid">37146632</pub-id></citation></ref>
<ref id="B31">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Secker</surname> <given-names>T. J.</given-names>
</name>
<name>
<surname>Leighton</surname> <given-names>T. G.</given-names>
</name>
<name>
<surname>Offin</surname> <given-names>D. G.</given-names>
</name>
<name>
<surname>Birkin</surname> <given-names>P. R.</given-names>
</name>
<name>
<surname>Herv&#xe9;</surname> <given-names>R. C.</given-names>
</name>
<name>
<surname>Keevil</surname> <given-names>C. W.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>A cold water, ultrasonically activated stream efficiently removes proteins and prion-associated amyloid from surgical stainless steel</article-title>. <source>J. Hosp. infection</source> <volume>106</volume>, <fpage>649</fpage>&#x2013;<lpage>656</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1016/j.jhin.2020.09.021</pub-id>, PMID: <pub-id pub-id-type="pmid">32956784</pub-id></citation></ref>
<ref id="B32">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Valverde-L&#xf3;pez</surname> <given-names>F.</given-names>
</name>
<name>
<surname>Han</surname> <given-names>S.</given-names>
</name>
<name>
<surname>Coughlin</surname> <given-names>S.</given-names>
</name>
<name>
<surname>Thiruvengadam</surname> <given-names>N.</given-names>
</name>
<name>
<surname>Moreau</surname> <given-names>C.</given-names>
</name>
<name>
<surname>Akshintala</surname> <given-names>V. S.</given-names>
</name>
<etal/>
</person-group>. (<year>2021</year>). <article-title>Outcomes of endoscopic management of sterile walled-off pancreatic necrosis: A systematic review</article-title>. <source>Pancreas</source> <volume>50</volume>, <fpage>1357</fpage>&#x2013;<lpage>1362</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1097/MPA.0000000000001929</pub-id>, PMID: <pub-id pub-id-type="pmid">35041333</pub-id></citation></ref>
<ref id="B33">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>van Dalen</surname> <given-names>A. S. H.</given-names>
</name>
<name>
<surname>Swinkels</surname> <given-names>J. A.</given-names>
</name>
<name>
<surname>Coolen</surname> <given-names>S.</given-names>
</name>
<name>
<surname>Hackett</surname> <given-names>R.</given-names>
</name>
<name>
<surname>Schijven</surname> <given-names>M. P.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Improving teamwork and communication in the operating room by introducing the theatre cap challenge</article-title>. <source>J. perioperative Pract.</source> <volume>32</volume>, <fpage>4</fpage>&#x2013;<lpage>9</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1177/17504589211046723</pub-id>, PMID: <pub-id pub-id-type="pmid">35001734</pub-id></citation></ref>
<ref id="B34">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Vincenti</surname> <given-names>S.</given-names>
</name>
<name>
<surname>Colamesta</surname> <given-names>V.</given-names>
</name>
<name>
<surname>Nurchis</surname> <given-names>M. C.</given-names>
</name>
<name>
<surname>Damiani</surname> <given-names>G.</given-names>
</name>
<name>
<surname>Pascucci</surname> <given-names>D.</given-names>
</name>
<name>
<surname>Boninti</surname> <given-names>F.</given-names>
</name>
<etal/>
</person-group>. (<year>2021</year>). <article-title>Development of a checklist as self-assessment tool to evaluate the reprocessing of endoscopic instruments in an Italian teaching hospital</article-title>. <source>Eur. Rev. Med. Pharmacol. Sci.</source> <volume>25</volume>, <fpage>5029</fpage>&#x2013;<lpage>5041</lpage>., PMID: <pub-id pub-id-type="pmid">34355375</pub-id></citation></ref>
<ref id="B35">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wang</surname> <given-names>Y. F.</given-names>
</name>
<name>
<surname>Wu</surname> <given-names>Y.</given-names>
</name>
<name>
<surname>Liu</surname> <given-names>X. W.</given-names>
</name>
<name>
<surname>Li</surname> <given-names>J. G.</given-names>
</name>
<name>
<surname>Zhan</surname> <given-names>Y. Q.</given-names>
</name>
<name>
<surname>Liu</surname> <given-names>B.</given-names>
</name>
<etal/>
</person-group>. (<year>2023</year>). <article-title>Li BB et&#xa0;al: Effect of a disposable endoscope precleaning kit in the cleaning procedure of gastrointestinal endoscope: A multi-center observational study</article-title>. <source>World J. gastrointestinal endoscopy</source> <volume>15</volume>, <fpage>705</fpage>&#x2013;<lpage>714</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.4253/wjge.v15.i12.705</pub-id>, PMID: <pub-id pub-id-type="pmid">38187912</pub-id></citation></ref>
<ref id="B36">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wilder</surname> <given-names>J. A.</given-names>
</name>
<name>
<surname>Roth</surname> <given-names>K.</given-names>
</name>
</person-group> (<year>2012</year>). <article-title>Cleaning of instruments: an absolute requirement for successful reprocessing</article-title>. <source>Biomed. instrumentation Technol.</source> <volume>Suppl</volume>, <fpage>69</fpage>&#x2013;<lpage>72</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.2345/0899-8205-12.1.69</pub-id>, PMID: <pub-id pub-id-type="pmid">22559780</pub-id></citation></ref>
<ref id="B37">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhang</surname> <given-names>T.</given-names>
</name>
<name>
<surname>Lin</surname> <given-names>S.</given-names>
</name>
<name>
<surname>Zhou</surname> <given-names>Y.</given-names>
</name>
<name>
<surname>Hu</surname> <given-names>J.</given-names>
</name>
</person-group> (<year>2023</year>). <article-title>Several ML algorithms and their feature vector design for gas discrimination and concentration measurement with an ultrasonically catalyzed MOX sensor</article-title>. <source>ACS sensors</source> <volume>8</volume>, <fpage>665</fpage>&#x2013;<lpage>672</lpage>. doi:&#xa0;<pub-id pub-id-type="doi">10.1021/acssensors.2c02159</pub-id>, PMID: <pub-id pub-id-type="pmid">36696118</pub-id></citation></ref>
<ref id="B38">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhou</surname> <given-names>H. J.</given-names>
</name>
<name>
<surname>Zhu</surname> <given-names>L. T.</given-names>
</name>
<name>
<surname>Liang</surname> <given-names>Z.</given-names>
</name>
<name>
<surname>Guan</surname> <given-names>W.</given-names>
</name>
<name>
<surname>Liu</surname> <given-names>B. H.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Application of pulsed vacuum cleaning and disinfection machine in cleaning endoscopic instruments</article-title>. <source>Nurs. Pract. Res.</source> <volume>17</volume>, <fpage>3</fpage>.</citation></ref>
</ref-list>
</back>
</article>