<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3-mathml3.dtd">
<article article-type="research-article" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:ali="http://www.niso.org/schemas/ali/1.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" dtd-version="1.3" xml:lang="EN">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Cardiovasc. Med.</journal-id><journal-title-group>
<journal-title>Frontiers in Cardiovascular Medicine</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Cardiovasc. Med.</abbrev-journal-title></journal-title-group>
<issn pub-type="epub">2297-055X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fcvm.2026.1743828</article-id>
<article-version article-version-type="Version of Record" vocab="NISO-RP-8-2008"/>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Original Research</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>QMODE&#x002B; ablation mode: optimal parameter setting and impedance-adapted strategies</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author"><name><surname>Shi</surname><given-names>Xuesong</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="conceptualization" vocab-term-identifier="https://credit.niso.org/contributor-roles/conceptualization/">Conceptualization</role><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Data curation" vocab-term-identifier="https://credit.niso.org/contributor-roles/data-curation/">Data curation</role><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Formal analysis" vocab-term-identifier="https://credit.niso.org/contributor-roles/formal-analysis/">Formal analysis</role><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="investigation" vocab-term-identifier="https://credit.niso.org/contributor-roles/investigation/">Investigation</role><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Project administration" vocab-term-identifier="https://credit.niso.org/contributor-roles/project-administration/">Project administration</role><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="software" vocab-term-identifier="https://credit.niso.org/contributor-roles/software/">Software</role><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="validation" vocab-term-identifier="https://credit.niso.org/contributor-roles/validation/">Validation</role><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="visualization" vocab-term-identifier="https://credit.niso.org/contributor-roles/visualization/">Visualization</role><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; original draft" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-original-draft/">Writing &#x2013; original draft</role></contrib>
<contrib contrib-type="author" corresp="yes"><name><surname>Sun</surname><given-names>Mingyu</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="corresp" rid="cor1">&#x002A;</xref><uri xlink:href="https://loop.frontiersin.org/people/2625114/overview"/><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="conceptualization" vocab-term-identifier="https://credit.niso.org/contributor-roles/conceptualization/">Conceptualization</role><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Data curation" vocab-term-identifier="https://credit.niso.org/contributor-roles/data-curation/">Data curation</role><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="methodology" vocab-term-identifier="https://credit.niso.org/contributor-roles/methodology/">Methodology</role><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="resources" vocab-term-identifier="https://credit.niso.org/contributor-roles/resources/">Resources</role><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &#x0026; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-review-editing/">Writing &#x2013; review &#x0026; editing</role></contrib>
<contrib contrib-type="author" corresp="yes"><name><surname>Wang</surname><given-names>Zulu</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="corresp" rid="cor1">&#x002A;</xref><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Project administration" vocab-term-identifier="https://credit.niso.org/contributor-roles/project-administration/">Project administration</role><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="supervision" vocab-term-identifier="https://credit.niso.org/contributor-roles/supervision/">Supervision</role><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="validation" vocab-term-identifier="https://credit.niso.org/contributor-roles/validation/">Validation</role><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &#x0026; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-review-editing/">Writing &#x2013; review &#x0026; editing</role></contrib>
<contrib contrib-type="author"><name><surname>Liang</surname><given-names>Ming</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/1977808/overview" /><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="investigation" vocab-term-identifier="https://credit.niso.org/contributor-roles/investigation/">Investigation</role><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Project administration" vocab-term-identifier="https://credit.niso.org/contributor-roles/project-administration/">Project administration</role><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="software" vocab-term-identifier="https://credit.niso.org/contributor-roles/software/">Software</role><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &#x0026; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-review-editing/">Writing &#x2013; review &#x0026; editing</role></contrib>
<contrib contrib-type="author"><name><surname>Jin</surname><given-names>Zhiqing</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Project administration" vocab-term-identifier="https://credit.niso.org/contributor-roles/project-administration/">Project administration</role><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="visualization" vocab-term-identifier="https://credit.niso.org/contributor-roles/visualization/">Visualization</role><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &#x0026; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-review-editing/">Writing &#x2013; review &#x0026; editing</role></contrib>
<contrib contrib-type="author"><name><surname>Ding</surname><given-names>Jian</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="resources" vocab-term-identifier="https://credit.niso.org/contributor-roles/resources/">Resources</role><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="software" vocab-term-identifier="https://credit.niso.org/contributor-roles/software/">Software</role><role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &#x0026; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-review-editing/">Writing &#x2013; review &#x0026; editing</role></contrib>
</contrib-group>
<aff id="aff1"><label>1</label><institution>State Key Laboratory of Frigid Zone Cardiovascular Disease, Cardiovascular Research Institute and Department of Cardiology, General Hospital of Northern Theater Command</institution>, <city>Shenyang</city>, <country country="cn">China</country></aff>
<aff id="aff2"><label>2</label><institution>Dalian Medical University</institution>, <city>Dalian</city>, <country country="cn">China</country></aff>
<author-notes>
<corresp id="cor1"><label>&#x002A;</label><bold>Correspondence:</bold> Mingyu Sun <email xlink:href="mailto:sunmingyu1976@126.com">sunmingyu1976@126.com</email> Zulu Wang <email xlink:href="mailto:wangzulu62@126.com">wangzulu62@126.com</email></corresp>
</author-notes>
<pub-date publication-format="electronic" date-type="pub" iso-8601-date="2026-02-05"><day>05</day><month>02</month><year>2026</year></pub-date>
<pub-date publication-format="electronic" date-type="collection"><year>2026</year></pub-date>
<volume>13</volume><elocation-id>1743828</elocation-id>
<history>
<date date-type="received"><day>11</day><month>11</month><year>2025</year></date>
<date date-type="rev-recd"><day>18</day><month>01</month><year>2026</year></date>
<date date-type="accepted"><day>19</day><month>01</month><year>2026</year></date>
</history>
<permissions>
<copyright-statement>&#x00A9; 2026 Shi, Sun, Wang, Liang, Jin and Ding.</copyright-statement>
<copyright-year>2026</copyright-year><copyright-holder>Shi, Sun, Wang, Liang, Jin and Ding</copyright-holder><license><ali:license_ref start_date="2026-02-05">https://creativecommons.org/licenses/by/4.0/</ali:license_ref><license-p>This is an open-access article distributed under the terms of the <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">Creative Commons Attribution License (CC BY)</ext-link>. The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</license-p></license>
</permissions>
<abstract><sec><title>Background</title>
<p>A new catheter (the QDOT-MICRO catheter) is used for high-power short duration (vHPSD) ablation.</p>
</sec><sec><title>Objectives</title>
<p>This study aimed to optimize lesion formation in QMODE&#x002B; ablation (using QDOT-MICRO catheter) by clarifying effects of key parameters and developing impedance-adapted strategies.</p>
</sec><sec><title>Methods</title>
<p>Radio frequency (RF) ablation was performed on excised porcine myocardium with QDOT-MICRO catheter under QMODE&#x002B; ablation mode. Parameters included contact force (CF), power, RF duration, interlesion distance, contact angle, and impedance. The optimal parameter was determined, and adjustments for consistent lesion formation across varying impedances were investigated.</p>
</sec><sec><title>Results</title>
<p>In QMODE&#x002B; ablation mode, lesion size (surface width and depth) increased with higher CF, longer RF duration, and greater power, but decreased as impedance elevated. However, lesions became smaller when CF exceeded 25&#x2005;g, due to rapid temperature drops from the QMODE&#x002B; temperature control system. Perpendicular contact resulted in greater lesion depth compared to parallel contact. An interlesion distance of 5&#x2005;mm was used as an experimentally evaluated reference condition and produced continuous lesions without excessive overlap. For impedance adjustments, 80&#x2005;W/3&#x2005;s, 80&#x2005;W/4&#x2005;s, and 90&#x2005;W/3&#x2005;s at 90&#x03A9; under QMODE&#x002B; ablation mode produced lesions comparable to those at 120&#x03A9;; when the impedance was high at 150&#x03A9;, switching to QMODE ablation mode with AI&#x2009;&#x003D;&#x2009;400/420 achieved similar lesion characteristics comparable to those at 120&#x03A9;.</p>
</sec><sec><title>Conclusions</title>
<p>Routine QMODE&#x002B; ablation with 90&#x2005;W power, 4&#x2005;s RF duration, catheter CF&#x2009;&#x003C;&#x2009;25&#x2005;g, 5&#x2005;mm interlesion distance (reference in this <italic>ex vivo</italic> model), and perpendicular contact achieves optimal lesion formation. To ensure consistent damage across different impedances, adjust QMODE&#x002B; parameters at low impedance and switch to QMODE at high impedance. Parallel contact could be preferred at fragile sites or under low impedance to reduce lesion depth and avoid over-damage.</p>
</sec>
</abstract>
<kwd-group>
<kwd>impedance</kwd>
<kwd>impedance-adapted strategies</kwd>
<kwd>lesion characteristics</kwd>
<kwd>parameter setting</kwd>
<kwd>QMODE&#x002B; ablation</kwd>
</kwd-group><funding-group><funding-statement>The author(s) declared that financial support was received for this work and/or its publication. This work was supported by the Liaoning Provincial Science and Technology Plan Joint Program Key R&#x0026;D Project titled &#x201C;Research on Overall Process Optimization of One-stop Procedure for Catheter Ablation Combined with Left Atrial Appendage Occlusion in Atrial Fibrillation&#x201D; (Grant No.: 2025JH2/101800030). The funding source had no role in the design of the study, collection, analysis, or interpretation of data, or in the writing of the manuscript.</funding-statement></funding-group><counts>
<fig-count count="10"/>
<table-count count="6"/><equation-count count="0"/><ref-count count="25"/><page-count count="13"/><word-count count="6548"/></counts><custom-meta-group><custom-meta><meta-name>section-at-acceptance</meta-name><meta-value>Cardiac Rhythmology</meta-value></custom-meta></custom-meta-group>
</article-meta>
</front>
<body><sec id="s1" sec-type="intro"><label>1</label><title>Introduction</title>
<p>Although pulsed field ablation has gained significant traction in electrophysiology, radio frequency (RF) energy remains a widely used modality for pulmonary vein isolation (PVI) of atrial fibrillation (AF). Establishing durable RF lesions is critical to reducing arrhythmia recurrence (<xref ref-type="bibr" rid="B1">1</xref>, <xref ref-type="bibr" rid="B2">2</xref>). Due to technical and procedural optimization in RF ablation, long-term success rates for PVI in patients with paroxysmal atrial fibrillation (PAF) are satisfying. Nevertheless, the main cause for AF recurrence is related to pulmonary vein (PV) reconnection due to initially non-transmural lesions and tissue oedema (<xref ref-type="bibr" rid="B3">3</xref>, <xref ref-type="bibr" rid="B4">4</xref>). Factors such as ablation power, duration, catheter-tissue contact force (CF), and impedance significantly influence lesion formation (<xref ref-type="bibr" rid="B5">5</xref>&#x2013;<xref ref-type="bibr" rid="B8">8</xref>). High power and short duration (HPSD; &#x2265;50&#x2005;W, typically &#x003C;15&#x2005;s) radio frequency ablation replacement strategies have been widely used in clinical settings to maintain or even improve the effectiveness and safety of lesion creation (<xref ref-type="bibr" rid="B9">9</xref>). Clinical applications of HPSD are limited to 50&#x2005;W. Recently, a catheter with a multi-thermocouple system has been developed for accurate temperature monitoring, allowing real-time temperature assessment of the catheter-tissue interface (<xref ref-type="bibr" rid="B10">10</xref>&#x2013;<xref ref-type="bibr" rid="B13">13</xref>). This new catheter is capable of performing extremely very high power short duration (vHPSD) applications (up to 90&#x2005;W and 4&#x2005;s) in QMODE&#x002B; ablation mode. Current research on vHPSD ablation parameters remains limited, with no systematic studies specifically addressing this field, particularly the critical issue of parameter adjustment strategies under varying impedance conditions. Therefore, the objective of this study was to systematically characterize lesion geometry under vHPSD ablation in an <italic>ex vivo</italic> myocardial model, focusing on the effects of power, impedance, catheter orientation, and inter-lesion spacing. We further evaluated optimal parameter adjustment strategies across different impedance scenarios.</p>
</sec>
<sec id="s2" sec-type="methods"><label>2</label><title>Methods</title>
<sec id="s2a"><label>2.1</label><title><italic>Ex vivo</italic> experimental models</title>
<p>Freshly excised porcine hearts, obtained within 12&#x2013;48&#x2005;h, were used in the experiments. The cardiac tissues were obtained from a licensed commercial slaughterhouse in Shenyang, Liaoning Province, China, as food-industry by-products following routine slaughter for human consumption. The hearts were placed in a circulating saline bath (400&#x2005;mL/min flow rate, 3.5&#x2005;g/L NaCl). The atrium was dissected into uniform slices and submerged in a 37 &#x2103; saline bath. Details of this <italic>in vitro</italic> model have been previously described (<xref ref-type="bibr" rid="B14">14</xref>, <xref ref-type="bibr" rid="B15">15</xref>). A 3.5&#x2005;mm tip-irrigated ablation catheter QDOT MICRO&#x2122;, Biosense Webster, Irvine, CA, USA), featuring three microelectrodes and six thermocouples, was utilized for the RF applications. The catheter was securely fixed in a plastic tube within the tank to ensure stable RF power delivery during ablation.</p>
</sec>
<sec id="s2b"><label>2.2</label><title>Ablation settings</title>
<p>All RF applications were delivered using a point-by-point ablation technique. Dragging or continuous ablation was not performed in any experimental condition. During energy delivery, the ablation catheter was maintained in a stable position with a near-perpendicular orientation to the myocardial surface. Catheter orientation and contact force were kept constant throughout each application to minimize variability related to catheter&#x2013;tissue interaction. The vHPSD was performed at 90&#x2005;W for 4&#x2005;s using the QDOT-MICRO catheter, whereas our study focused on adjusting these parameters within QMODE&#x002B; ablation mode&#x2014;specifically modifying CFs, power, ablation duration, interlesion distance, contact angle and impedance. Controlling for a single variable, we examined the changes in lesion characteristics. To ensure consistent ablation damage across varying impedances, impedance categories were established, with corresponding adjustments to power and duration to achieve comparable lesion formation. For persistent inconsistencies despite QMODE&#x002B; optimization, QMODE ablation mode was adopted as an alternative to refine energy delivery. During interlesion distance experiments, the catheter was kept at a constant contact angle and orientation: the catheter long axis was oriented perpendicular to the intended ablation line, and successive applications were delivered in the same direction, while contact force was maintained within the preset range (10&#x2013;15&#x2005;g) for that experiment. Interlesion distances of &#x2265;3&#x2005;mm were predefined and tested as experimental conditions. These distances were selected to represent commonly used spacing ranges in ablation and to allow controlled comparison of lesion continuity in an <italic>ex vivo</italic> setting. For the additional QMODE ablation mode experiments at 150&#x03A9;, power was fixed at 50&#x2005;W with CF maintained at 10&#x2013;15&#x2005;g, and RF delivery was terminated when the preset AI target (360&#x2013;460) was reached.</p>
</sec>
<sec id="s2c"><label>2.3</label><title>RF lesion assessment</title>
<p>The lesion&#x0027;s long axis was crossed, and the white area was measured using a digital caliper with a resolution of 0.01&#x2005;mm to determine both the maximum depth and the maximum surface diameter of the lesion. All lesion measurements were performed by the same individual, who was blinded to the ablation setting parameters during the measurement process. To investigate ablation inconsistencies under varying impedances, 2&#x2005;mm-thick frozen sections were prepared (<xref ref-type="bibr" rid="B16">16</xref>, <xref ref-type="bibr" rid="B17">17</xref>). The sections were placed in a 1&#x0025; triphenyl tetrazolium chloride (TTC) solution, immersed in TTC-containing dishes, and incubated in a 37 &#x00B0;C light-protected water bath for 15&#x2013;30&#x2005;min with continuous rotation to ensure uniformity. TTC induced red coloration of mitochondrial succinate dehydrogenase in viable cells, distinguishing live (red) from non-viable (pale) tissues (<xref ref-type="bibr" rid="B16">16</xref>, <xref ref-type="bibr" rid="B18">18</xref>). Following reaction termination, the sections were washed with PBS and fixed with 4&#x0025; polyformaldehyde. Steam pops were monitored continuously by direct visual inspection, audible cues, and real-time impedance tracing on the generator.</p>
</sec>
<sec id="s2d"><label>2.4</label><title>Statistical analysis</title>
<p>Continuous variables, including lesion surface width and lesion depth, were expressed as mean&#x2009;&#x00B1;&#x2009;standard deviation (SD). Comparisons among multiple experimental groups were performed using one-way analysis of variance (ANOVA). Due to the multiple comparisons involving lesion features, pairwise comparisons were adjusted using the Bonferroni correction to assess significant differences. Categorical variables were presented as counts (percentages) and compared using the <italic>&#x03C7;</italic><sup>2</sup> test or Fisher&#x0027;s exact test, as appropriate. A <italic>p</italic>-value of &#x003C;0.05 was considered statistically significant. All statistical analyses were performed using SPSS 27.0 software.</p>
</sec>
</sec>
<sec id="s3" sec-type="results"><label>3</label><title>Results</title>
<p>Across all applications, no steam pops were observed under the monitoring methods described above.</p>
<sec id="s3a"><label>3.1</label><title>Lesion characteristics in QMODE&#x002B; ablation mode using different CFs</title>
<p>The CF groups were set as follows: 0&#x2013;5&#x2005;g, 5&#x2013;10&#x2005;g, 10&#x2013;15&#x2005;g, 15&#x2013;20&#x2005;g, 20&#x2013;25&#x2005;g, and 25&#x2013;30&#x2005;g, with five lesions in each group (see <xref ref-type="table" rid="T1">Table&#x00A0;1</xref>). Lesion characteristics were illustrated in <xref ref-type="fig" rid="F1">Figure&#x00A0;1A</xref>. The smallest lesion depth and surface width were observed in the 0&#x2013;5&#x2005;g CF group. As shown in <xref ref-type="table" rid="T1">Table&#x00A0;1</xref>, lesion depth and surface width increased with increasing CF in the range&#x2009;&#x003C;&#x2009;25&#x2005;g. However, when CF reached over 25&#x2005;g, lesion depth and surface width did not increase further; instead, they showed signs of reduced damage. When comparing adjacent groups, no statistical difference was observed in surface width, but significant differences in lesion depth emerged when CF&#x2009;&#x003E;&#x2009;10&#x2013;15&#x2005;g (<italic>P</italic>&#x2009;&#x003C;&#x2009;0.01, <italic>P</italic>&#x2009;&#x003C;&#x2009;0.001, <italic>P</italic>&#x2009;&#x003C;&#x2009;0.001) (as shown in <xref ref-type="fig" rid="F1">Figure&#x00A0;1B</xref>). <xref ref-type="fig" rid="F2">Figure&#x00A0;2</xref> presents examples of QMODE&#x002B; ablation mode parameters during RF application at a target temperature of 60&#x2103; under different CF conditions: when CF exceeded 15&#x2005;g, the temperature drop intensified, particularly over 25&#x2005;g, resulting in relatively smaller lesions.</p>
<table-wrap id="T1" position="float"><label>Table&#x00A0;1</label>
<caption><p>Lesion characteristics in QMODE&#x002B; ablation mode using different CFs.</p></caption>
<table>
<colgroup>
<col align="left"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
</colgroup>
<thead>
<tr>
<th valign="top" align="left" rowspan="2">Lesion Parameters</th>
<th valign="top" align="center">CF&#x2009;&#x003D;&#x2009;0&#x2013;5&#x2005;g</th>
<th valign="top" align="center">CF&#x2009;&#x003D;&#x2009;5&#x2013;10&#x2005;g</th>
<th valign="top" align="center">CF&#x2009;&#x003D;&#x2009;10&#x2013;15&#x2005;g</th>
<th valign="top" align="center">CF&#x2009;&#x003D;&#x2009;15&#x2013;20&#x2005;g</th>
<th valign="top" align="center">CF&#x2009;&#x003D;&#x2009;20&#x2013;25&#x2005;g</th>
<th valign="top" align="center">CF&#x2009;&#x003D;&#x2009;25&#x2013;30&#x2005;g</th>
</tr>
<tr>
<th valign="top" align="center"><italic>N</italic>&#x2009;&#x003D;&#x2009;5</th>
<th valign="top" align="center"><italic>N</italic>&#x2009;&#x003D;&#x2009;5</th>
<th valign="top" align="center"><italic>N</italic>&#x2009;&#x003D;&#x2009;5</th>
<th valign="top" align="center"><italic>N</italic>&#x2009;&#x003D;&#x2009;5</th>
<th valign="top" align="center"><italic>N</italic>&#x2009;&#x003D;&#x2009;5</th>
<th valign="top" align="center"><italic>N</italic>&#x2009;&#x003D;&#x2009;5</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Surface width</td>
<td valign="top" align="center">6.18&#x2009;&#x00B1;&#x2009;0.12</td>
<td valign="top" align="center">6.41&#x2009;&#x00B1;&#x2009;0.41</td>
<td valign="top" align="center">6.72&#x2009;&#x00B1;&#x2009;0.21</td>
<td valign="top" align="center">7.46&#x2009;&#x00B1;&#x2009;0.27</td>
<td valign="top" align="center">7.90&#x2009;&#x00B1;&#x2009;0.68</td>
<td valign="top" align="center">7.36&#x2009;&#x00B1;&#x2009;0.61</td>
</tr>
<tr>
<td valign="top" align="left">Lesion depth</td>
<td valign="top" align="center">2.92&#x2009;&#x00B1;&#x2009;0.11</td>
<td valign="top" align="center">3.06&#x2009;&#x00B1;&#x2009;0.13</td>
<td valign="top" align="center">3.17&#x2009;&#x00B1;&#x2009;0.12</td>
<td valign="top" align="center">3.48&#x2009;&#x00B1;&#x2009;0.09</td>
<td valign="top" align="center">3.94&#x2009;&#x00B1;&#x2009;0.06</td>
<td valign="top" align="center">3.25&#x2009;&#x00B1;&#x2009;0.09</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="TF1"><p>CF, contact force.</p></fn>
</table-wrap-foot>
</table-wrap>
<fig id="F1" position="float"><label>Figure&#x00A0;1</label>
<caption><p>Effect of CFs on ablation lesion extent. <bold>(A)</bold> Gross lesion morphology. <bold>(B)</bold> Surface width and depth of lesions formed when the catheter was in perpendicular contact with tissue in QMODE&#x002B; ablation mode. Statistical significance is indicated as &#x002A;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.05, &#x002A;&#x002A;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.01, &#x002A;&#x002A;&#x002A;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.001.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fcvm-13-1743828-g001.tif"><alt-text content-type="machine-generated">Label A shows cross-sections of samples with varying weights from 0 to 30 grams, providing measurements for width and depth in millimeters. Label B presents a bar graph comparing the average width and depth across the same weight groups, with statistically significant differences indicated by asterisks, suggesting variability in measurements.</alt-text>
</graphic>
</fig>
<fig id="F2" position="float"><label>Figure&#x00A0;2</label>
<caption><p>An example of the QMODE&#x002B; ablation parameters created by RF application with a target temperature of 60&#x00B0;C under varying CF is shown. When CF exceeds 15&#x2005;g, frequent power titration occurs, and the temperature drops rapidly.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fcvm-13-1743828-g002.tif"><alt-text content-type="machine-generated">Six line graphs display data for contact force ranges from 0 to 30 grams in five-gram increments. Each graph plots power, temperature, impedance, and contact force. A target temperature line is set at sixty degrees Celsius. Graphs show variations in these parameters across different contact force ranges.</alt-text>
</graphic>
</fig>
</sec>
<sec id="s3b"><label>3.2</label><title>Lesion characteristics in QMODE&#x002B; ablation mode using different power</title>
<p>Different power (90&#x2005;W, 80&#x2005;W, 70&#x2005;W, 60&#x2005;W, and 51&#x2005;W-the minimum procedure setting) were used to generate 5 lesions in each group (<xref ref-type="table" rid="T2">Table&#x00A0;2</xref>). Both the surface width and lesion depth were greatest at 90&#x2005;W, and decreased as the power wattage decreased. When comparing adjacent groups, there was a statistical difference in surface width between the 51&#x2005;W vs. 60&#x2005;W, 60&#x2005;W vs. 70&#x2005;W, and 70&#x2005;W vs. 80&#x2005;W groups (<italic>P</italic>&#x2009;&#x003C;&#x2009;0.001, <italic>P</italic>&#x2009;&#x003D;&#x2009;0.002, <italic>P</italic>&#x2009;&#x003D;&#x2009;0.015), and a statistical difference in lesion depth between the 60&#x2005;W vs. 70&#x2005;W and 70&#x2005;W vs. 80&#x2005;W groups (all <italic>P</italic>&#x2009;&#x003C;&#x2009;0.001) (as shown in <xref ref-type="fig" rid="F3">Figure&#x00A0;3B</xref>). The lesion features are shown in <xref ref-type="fig" rid="F3">Figure&#x00A0;3A</xref>.</p>
<table-wrap id="T2" position="float"><label>Table&#x00A0;2</label>
<caption><p>Lesion characteristics in QMODE&#x002B; ablation mode using different power.</p></caption>
<table>
<colgroup>
<col align="left"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
</colgroup>
<thead>
<tr>
<th valign="top" align="left">Lesion Parameters</th>
<th valign="top" align="center">51&#x2005;W</th>
<th valign="top" align="center">60&#x2005;W</th>
<th valign="top" align="center">70&#x2005;W</th>
<th valign="top" align="center">80&#x2005;W</th>
<th valign="top" align="center">90&#x2005;W</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Surface width</td>
<td valign="top" align="center">4.24&#x2009;&#x00B1;&#x2009;0.29</td>
<td valign="top" align="center">5.16&#x2009;&#x00B1;&#x2009;0.17</td>
<td valign="top" align="center">5.90&#x2009;&#x00B1;&#x2009;0.35</td>
<td valign="top" align="center">6.48&#x2009;&#x00B1;&#x2009;0.25</td>
<td valign="top" align="center">6.61&#x2009;&#x00B1;&#x2009;0.13</td>
</tr>
<tr>
<td valign="top" align="left">Lesion depth</td>
<td valign="top" align="center">1.73&#x2009;&#x00B1;&#x2009;0.19</td>
<td valign="top" align="center">1.91&#x2009;&#x00B1;&#x2009;0.20</td>
<td valign="top" align="center">2.51&#x2009;&#x00B1;&#x2009;0.15</td>
<td valign="top" align="center">3.13&#x2009;&#x00B1;&#x2009;0.11</td>
<td valign="top" align="center">3.25&#x2009;&#x00B1;&#x2009;0.13</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="TF2"><p><italic>N</italic>&#x2009;&#x003D;&#x2009;5 in each group.</p></fn>
</table-wrap-foot>
</table-wrap>
<fig id="F3" position="float"><label>Figure&#x00A0;3</label>
<caption><p>Effect of power on ablation lesion extent. <bold>(A)</bold> Gross lesion morphology. <bold>(B)</bold> Surface width and depth of lesions formed using different power when the catheter was in perpendicular contact with tissue in QMODE&#x002B; ablation mode. Statistical significance is indicated as &#x002A;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.05, &#x002A;&#x002A;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.01, &#x002A;&#x002A;&#x002A;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.001.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fcvm-13-1743828-g003.tif"><alt-text content-type="machine-generated">Diagram A shows images of materials with measurements of width and depth in millimeters under power levels: 51W, 60W, 70W, 80W, and 90W. Diagram B is a bar chart comparing the width (in blue) and depth (in orange) for each power level, with significance indicated by asterisks.</alt-text>
</graphic>
</fig>
</sec>
<sec id="s3c"><label>3.3</label><title>Lesion characteristics in QMODE&#x002B; ablation mode with different RF durations</title>
<p>The RF durations were divided into four groups: 4&#x2005;s, 3&#x2005;s, 2&#x2005;s, and 1&#x2005;s, with 5 lesions in each group (as shown in <xref ref-type="table" rid="T3">Table&#x00A0;3</xref> and <xref ref-type="fig" rid="F4">Figure&#x00A0;4A</xref>). Mean values indicated that lesion size increased as RF duration prolonged. Statistically significant differences in lesion surface width and depth were observed across all groups (<xref ref-type="fig" rid="F4">Figure&#x00A0;4B</xref>).</p>
<table-wrap id="T3" position="float"><label>Table&#x00A0;3</label>
<caption><p>Lesion characteristics in QMODE&#x002B; ablation mode with different RF durations.</p></caption>
<table>
<colgroup>
<col align="left"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
</colgroup>
<thead>
<tr>
<th valign="top" align="left">Lesion Parameters</th>
<th valign="top" align="center">1&#x2005;S</th>
<th valign="top" align="center">2&#x2005;S</th>
<th valign="top" align="center">3&#x2005;S</th>
<th valign="top" align="center">4&#x2005;S</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Surface width</td>
<td valign="top" align="center">3.00&#x2009;&#x00B1;&#x2009;0.40</td>
<td valign="top" align="center">4.60&#x2009;&#x00B1;&#x2009;0.16</td>
<td valign="top" align="center">5.55&#x2009;&#x00B1;&#x2009;0.12</td>
<td valign="top" align="center">6.59&#x2009;&#x00B1;&#x2009;0.11</td>
</tr>
<tr>
<td valign="top" align="left">Lesion depth</td>
<td valign="top" align="center">0.90&#x2009;&#x00B1;&#x2009;0.24</td>
<td valign="top" align="center">1.81&#x2009;&#x00B1;&#x2009;0.07</td>
<td valign="top" align="center">2.27&#x2009;&#x00B1;&#x2009;0.12</td>
<td valign="top" align="center">3.24&#x2009;&#x00B1;&#x2009;0.14</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="TF3"><p><italic>N</italic>&#x2009;&#x003D;&#x2009;5 in each group.</p></fn>
</table-wrap-foot>
</table-wrap>
<fig id="F4" position="float"><label>Figure&#x00A0;4</label>
<caption><p>Effect of RF durations on ablation lesion extent. <bold>(A)</bold> Gross lesion morphology. <bold>(B)</bold> Surface width and depth of lesions formed under different RF durations when the catheter was in perpendicular contact with tissue in QMODE&#x002B; ablation mode. Statistical significance is indicated as &#x002A;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.05, &#x002A;&#x002A;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.01, &#x002A;&#x002A;&#x002A;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.001.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fcvm-13-1743828-g004.tif"><alt-text content-type="machine-generated">Image A shows four cuts of tissue labeled 1S, 2S, 3S, and 4S, with measurements for width and depth in millimeters. Image B is a bar chart showing width and depth of the tissue cuts from Image A for variable RF durations. Width values are higher than depth values, with significant differences indicated by asterisks.</alt-text>
</graphic>
</fig>
</sec>
<sec id="s3d"><label>3.4</label><title>Lesion characteristics in QMODE&#x002B; ablation mode at different contact angles</title>
<p>Generally, due to the larger contact area in the parallel contact group, the average surface widths were greater than those in the perpendicular contact group. Conversely, the average tissue depths in the perpendicular contact group exceeded those in the parallel contact group (as shown in <xref ref-type="table" rid="T4">Table&#x00A0;4</xref>). <xref ref-type="fig" rid="F5">Figure&#x00A0;5A</xref> shows the effect of different contact angles of ablation catheter on lesion formation. Statistically significant differences in lesion surface width and lesion depth were observed across all groups (<xref ref-type="fig" rid="F5">Figure&#x00A0;5B</xref>).</p>
<table-wrap id="T4" position="float"><label>Table&#x00A0;4</label>
<caption><p>Lesion characteristics in QMODE&#x002B; ablation mode at different contact angles.</p></caption>
<table>
<colgroup>
<col align="left"/>
<col align="center"/>
<col align="center"/>
</colgroup>
<thead>
<tr>
<th valign="top" align="left">Lesion Parameters</th>
<th valign="top" align="center">Parallel</th>
<th valign="top" align="center">Perpendicular</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Surface width</td>
<td valign="top" align="center">7.38&#x2009;&#x00B1;&#x2009;0.53</td>
<td valign="top" align="center">6.46&#x2009;&#x00B1;&#x2009;0.38</td>
</tr>
<tr>
<td valign="top" align="left">Lesion depth</td>
<td valign="top" align="center">2.32&#x2009;&#x00B1;&#x2009;0.19</td>
<td valign="top" align="center">3.09&#x2009;&#x00B1;&#x2009;0.18</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="TF4"><p><italic>N</italic>&#x2009;&#x003D;&#x2009;5 in each group.</p></fn>
</table-wrap-foot>
</table-wrap>
<fig id="F5" position="float"><label>Figure&#x00A0;5</label>
<caption><p>Effect of contact angles on ablation lesion extent. <bold>(A)</bold> Gross lesion morphology. <bold>(B)</bold> Surface width and depth of lesions formed under different contact angles with tissue in QMODE&#x002B; ablation mode. Statistical significance is indicated as &#x002A;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.05, &#x002A;&#x002A;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.01, &#x002A;&#x002A;&#x002A;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.001.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fcvm-13-1743828-g005.tif"><alt-text content-type="machine-generated">Two-part image showing tissue measurements and a bar graph. Top section (A) depicts cut meat, with widths and depths measured in two orientations: parallel and perpendicular, with specific dimensions labeled. Bottom section (B) features a bar graph titled \"Variable contact angles,\" comparing these dimensions. Parallel shows greater width than perpendicular, indicated by bars with statistical significance markers.</alt-text>
</graphic>
</fig>
</sec>
<sec id="s3e"><label>3.5</label><title>Evaluation of interlesion distance</title>
<p>The interlesion distance of RF applications was gradually increased, with a minimum distance of 3&#x2005;mm to a maximum of 7&#x2005;mm. Ablation interlesion distances at 3&#x2005;mm and 4&#x2005;mm significantly increased lesion interlesion depth, whereas a 6&#x2005;mm interlesion distance resulted in insufficient depth at the connected region, with potentiated possibility of gaps forming (<xref ref-type="table" rid="T5">Table&#x00A0;5</xref> and <xref ref-type="fig" rid="F6">Figure&#x00A0;6B</xref>). When the interlesion distance was &#x2265;7&#x2005;mm, RF applications produced lesions with isolated discontinuities, as shown in <xref ref-type="fig" rid="F6">Figure&#x00A0;6A</xref>.</p>
<table-wrap id="T5" position="float"><label>Table&#x00A0;5</label>
<caption><p>Lesion interlesion depth in QMODE&#x002B; ablation mode with different interlesion distance.</p></caption>
<table>
<colgroup>
<col align="left"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
</colgroup>
<thead>
<tr>
<th valign="top" align="left">Lesion Parameters</th>
<th valign="top" align="center">3&#x2005;mm</th>
<th valign="top" align="center">4&#x2005;mm</th>
<th valign="top" align="center">5&#x2005;mm</th>
<th valign="top" align="center">6&#x2005;mm</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Lesion depth</td>
<td valign="top" align="center">3.50&#x2009;&#x00B1;&#x2009;0.17</td>
<td valign="top" align="center">2.51&#x2009;&#x00B1;&#x2009;0.14</td>
<td valign="top" align="center">2.07&#x2009;&#x00B1;&#x2009;0.12</td>
<td valign="top" align="center">1.67&#x2009;&#x00B1;&#x2009;0.11</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="TF5"><p><italic>N</italic>&#x2009;&#x003D;&#x2009;5 in each group.</p></fn>
</table-wrap-foot>
</table-wrap>
<fig id="F6" position="float"><label>Figure&#x00A0;6</label>
<caption><p>Effect of interlesions on ablation lesion extent. <bold>(A)</bold> Gross lesion morphology. <bold>(B)</bold> Depth of lesions formed under different interlesions with tissue in QMODE&#x002B; ablation mode. Statistical significance is indicated as &#x002A;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.05, &#x002A;&#x002A;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.01, &#x002A;&#x002A;&#x002A;<italic>P</italic>&#x2009;&#x003C;v0.001.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fcvm-13-1743828-g006.tif"><alt-text content-type="machine-generated">Panel A shows close-up images of lesions with varying depths: 3 millimeters, 4 millimeters, 5 millimeters, 6 millimeters, 7 millimeters, and greater than 7 millimeters. Panel B is a bar chart titled \"Variable interlesion depths,\" displaying the mean depth in millimeters for each lesion category. Error bars indicate variability, with significant differences marked by asterisks.</alt-text>
</graphic>
</fig>
</sec>
<sec id="s3f"><label>3.6</label><title>Lesion characteristics in QMODE&#x002B; ablation mode with different impedances</title>
<p>Basic impedance was controlled by adjusting saline concentration and electrode plate distance, with four groups established as shown in <xref ref-type="table" rid="T6">Table&#x00A0;6</xref> (5 lesions per group). <xref ref-type="fig" rid="F7">Figure&#x00A0;7A</xref> showed representative lesions and three distinct regions were observed in the ablation lesions at 90&#x03A9;. Thus, in myocardial specimens stained with TTC, 90&#x03A9; lesions were clearly distinguishable to the naked eye. As shown in <xref ref-type="fig" rid="F7">Figure&#x00A0;7B</xref>, TTC staining well demarcated ablation lesions into three distinct regions: (1) a central dark brown area, (2) a lighter-edged region, and (3) normal red myocardial tissue. At a basic impedance of 90&#x03A9;, lesions exhibited the maximum average surface width and tissue depth. Lesion extent decreased as basic impedance elevated. No statistical differences in surface width or tissue depth were observed between adjacent groups (<xref ref-type="fig" rid="F7">Figure&#x00A0;7C</xref>).</p>
<table-wrap id="T6" position="float"><label>Table&#x00A0;6</label>
<caption><p>Lesion characteristics with different impedances.</p></caption>
<table>
<colgroup>
<col align="left"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
</colgroup>
<thead>
<tr>
<th valign="top" align="left">Lesion Parameters</th>
<th valign="top" align="center">90&#x03A9;</th>
<th valign="top" align="center">110&#x03A9;</th>
<th valign="top" align="center">130&#x03A9;</th>
<th valign="top" align="center">150&#x03A9;</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Surface width</td>
<td valign="top" align="center">6.60&#x2009;&#x00B1;&#x2009;0.28</td>
<td valign="top" align="center">6.52&#x2009;&#x00B1;&#x2009;0.43</td>
<td valign="top" align="center">6.01&#x2009;&#x00B1;&#x2009;0.52</td>
<td valign="top" align="center">5.67&#x2009;&#x00B1;&#x2009;0.49</td>
</tr>
<tr>
<td valign="top" align="left">Lesion depth</td>
<td valign="top" align="center">3.24&#x2009;&#x00B1;&#x2009;0.14</td>
<td valign="top" align="center">2.82&#x2009;&#x00B1;&#x2009;0.40</td>
<td valign="top" align="center">2.62&#x2009;&#x00B1;&#x2009;0.35</td>
<td valign="top" align="center">2.32&#x2009;&#x00B1;&#x2009;0.28</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="TF6"><p><italic>N</italic>&#x2009;&#x003D;&#x2009;5 in each group.</p></fn>
</table-wrap-foot>
</table-wrap>
<fig id="F7" position="float"><label>Figure&#x00A0;7</label>
<caption><p>Effect of impedance on ablation lesion extent. <bold>(A)</bold> Gross lesion morphology. <bold>(B)</bold> Comparison of ablation lesions with different impedances in the same TTC-stained myocardium. <bold>(C)</bold> Surface width and depth of lesions formed under different impedances when the catheter was in perpendicular contact with tissue in QMODE&#x002B; ablation mode. Statistical significance is indicated as &#x002A;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.05, &#x002A;&#x002A;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.01, &#x002A;&#x002A;&#x002A;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.001.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fcvm-13-1743828-g007.tif"><alt-text content-type="machine-generated">Panel A shows cross-sections of tissue samples categorized by impedance levels: 90Ω, 110Ω, 130Ω, and 150Ω, highlighting width and depth measurements in millimeters. Panel B presents a comparison of ablation lesions with different impedance values within the same TTC-stained myocardium, demonstrating visual differences. Panel C features a bar graph comparing width and depth across variable impedance groups, with width depicted in blue bars and depth in orange bars, indicating variations in measurement by impedance level.</alt-text>
</graphic>
</fig>
</sec>
<sec id="s3g"><label>3.7</label><title>Parameter adjustments for consistent lesion formation across varying impedances</title>
<p>This study hypothesized how ablation settings should be adjusted to achieve comparable ablation lesions in QMODE&#x002B; ablation mode when impedances varied. Impedances were divided into three groups: 90&#x03A9;, 120&#x03A9;, and 150&#x03A9;, with the 120&#x03A9; group (90&#x2005;W, 4&#x2005;s) serving as the control (intermediate impedance). <xref ref-type="fig" rid="F8">Figure&#x00A0;8</xref> showed that in the 90&#x03A9; group, the parameters 80&#x2005;W/3&#x2005;s, 80&#x2005;W/4&#x2005;s, and 90&#x2005;W/3&#x2005;s yielded lesions comparable to those in the control group, with no statistical differences in depth or width (<xref ref-type="sec" rid="s14">Supplementary Table S1</xref>). In contrast, <xref ref-type="fig" rid="F9">Figure&#x00A0;9</xref> indicated that lesion depths and widths in the 150&#x03A9; group were smaller than those in the control group (<xref ref-type="sec" rid="s14">Supplementary Table S2</xref>). To ensure consistent ablation damage at 150&#x03A9;, we conducted an additional set of experiments using QMODE mode at 150&#x03A9;, comparing with those in the control group. Results showed that at 150&#x03A9; with an AI of 400/420 in QMODE mode, lesion surface width and depth were similar to those in the control group (<xref ref-type="fig" rid="F10">Figure&#x00A0;10</xref> and <xref ref-type="sec" rid="s14">Supplementary Table S3</xref>).</p>
<fig id="F8" position="float"><label>Figure&#x00A0;8</label>
<caption><p>Box plots showing lesion width and depth for each tested ablation setting in 90&#x03A9; in QMODE&#x002B; ablation mode, compared to the control group (120&#x03A9;). Statistical significance is indicated as follows: &#x002A;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.05, &#x0023;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.01, &#x2020;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.001.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fcvm-13-1743828-g008.tif"><alt-text content-type="machine-generated">Box plots showing measurements of width and depth under different conditions labeled as QDOT-QMODE+. Width ranges from 5 to 7.5 millimeters, while depth ranges from 1.5 to 3.5 millimeters. Groups are 70W/3S, 70W/4S, 80W/3S, 80W/4S, 90W/3S, 90W/4S, and Control. Two columns labeled 90&#x03A9; and 120&#x03A9; are compared. Outliers are marked with circles.</alt-text>
</graphic>
</fig>
<fig id="F9" position="float"><label>Figure&#x00A0;9</label>
<caption><p>Box plots showing lesion width and depth for each tested ablation setting in 150&#x03A9; under QMODE&#x002B; ablation mode, compared to the control group (vHPSD-120&#x03A9;). Statistical significance is indicated as follows: &#x002A;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.05, &#x0023;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.01, &#x2020;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.001.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fcvm-13-1743828-g009.tif"><alt-text content-type="machine-generated">Two box plot graphs compare width and depth measurements in millimeters for different conditions under QDOT-QMODE+ at resistances of one hundred fifty ohms and one hundred twenty ohms. The x-axis labels indicate conditions: 70W/4s, 80W/3s, 80W/4s, 90W/3s, 90W/4s, and Control. The left graph shows width, and the right shows depth. Each condition displays variability with boxes and whiskers indicating distribution ranges.</alt-text>
</graphic>
</fig>
<fig id="F10" position="float"><label>Figure&#x00A0;10</label>
<caption><p>Box plot showing the damage width and depth for each tested ablation setting in QMODE ablation mode at 150&#x03A9;, compared to the control group (120&#x03A9;). Statistical significance is indicated as follows: &#x002A;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.05, &#x0023;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.01, &#x2020;<italic>P</italic>&#x2009;&#x003C;&#x2009;0.001.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fcvm-13-1743828-g010.tif"><alt-text content-type="machine-generated">Box plots compare width and depth measurements in millimeters for different conditions using QDOT-QMODE+ at 120 ohms and QDOT-QMODE at 150 ohms. Width ranges from 4.5 to 6.5 millimeters, and depth ranges from 1.0 to 4.0 millimeters. Data is categorized by ablation index (360 to 460) and a control group.</alt-text>
</graphic>
</fig>
</sec>
</sec>
<sec id="s4" sec-type="discussion"><label>4</label><title>Discussion</title>
<sec id="s4a"><label>4.1</label><title>Effects of different ablation parameters on damage degree in QMODE&#x002B; ablation mode</title>
<p>In this <italic>ex vivo</italic> experimental model, our primary aim was to compare lesions arising from different ablation parameters, all performed using the QDOT-MICRO catheter in temperature-controlled mode. Notable differences in lesion width and depth were observed. In power-temperature control mode, it is well established that higher CF correlates with greater tissue damage, attributed to increased catheter tip-tissue contact area and enhanced current flow into tissue (<xref ref-type="bibr" rid="B19">19</xref>). In this study, when CF exceeded 15&#x2005;g under QMODE&#x002B; ablation mode, tissue temperature decreased more rapidly&#x2014;particularly at 25&#x2005;g&#x2014;resulting in relatively smaller lesions. This phenomenon was attributed to more frequent power titrations inherent to temperature-control mode. The QDOT-MICRO catheter, equipped with three distal and three proximal thermocouples for monitoring tissue temperature throughout ablation, provides sensitive temperature tracking and dynamic power adjustment (<xref ref-type="bibr" rid="B20">20</xref>). This mechanism effectively balanced CF and RF power to achieve the observed lesion characteristics, as summarized in <xref ref-type="table" rid="T1">Table&#x00A0;1</xref>. Previous studies (<xref ref-type="bibr" rid="B21">21</xref>, <xref ref-type="bibr" rid="B22">22</xref>) have reported that both power wattage and RF duration are associated with lesion sizes, with higher power and longer RF duration correlating with increased lesion dimensions. Intermediate power settings (51&#x2013;80&#x2005;W for 4&#x2005;s) were included to characterize the dose&#x2013;response relationship between RF power and lesion characteristics in QMODE&#x002B; ablation mode, rather than to replicate routine clinical ablation strategies.</p>
<p>Consistent with previous reports (<xref ref-type="bibr" rid="B23">23</xref>), this study confirmed that perpendicular contact achieves greater ablation tissue depth than parallel contact. For ablation procedures: parallel contact was preferred at low impedance (to reduce lesion depth and avoid over-damage) and perpendicular contact at high impedance (to ensure therapeutic depth); prioritize parallel contact for fragile sites (e.g., thin posterior walls) to improve safety. This strategy balances ablation efficacy and procedural safety.</p>
<p>Bortone et al. (<xref ref-type="bibr" rid="B24">24</xref>) used CARTO and QDOT-MICRO catheters in temperature-controlled mode in eight adult sheep, confirming that lesions with interlesion distances of 3, 4, 5, and 6&#x2005;mm were histologically transmural and continuous. In our experiment, interlesion distances of 3&#x2005;mm and 4&#x2005;mm under QMODE&#x002B; ablation mode significantly increased interlesion depth, with a corresponding augmentation in the extent of interlesional damage; therefore, in thinner regions such as the posterior wall of left atrial, these ranges of interlesion distance might increase atrioesophageal fistula risk due to proximity to the esophagus. For the atrial anterior wall&#x2014;where myocardial tissue is relatively thicker and less susceptible to transmural injury&#x2014;an interlesion distance of 3&#x2013;4&#x2005;mm can be adopted to enhance the continuity and extent of ablation lesions, thereby ensuring sufficient damage. In contrast, a 6&#x2005;mm interlesion distance resulted in insufficient depth at the lesion junction, with gaps between the ablation points impairing continuity, which may increase the recurrence risk. As shown in <xref ref-type="fig" rid="F6">Figure&#x00A0;6</xref>, lesions were discontinuous obviously when interlesion distance was &#x2265;7&#x2005;mm. Given that each condition included only five lesions, 5&#x2005;mm can be considered a practical reference interlesion distance within the tested <italic>ex vivo</italic> conditions. Its applicability should be adjusted based on myocardial wall thickness and anatomical location.</p>
<p>The lower the impedance, the greater the damage. In our study, adjusting the RF duration exerted a significant impact on lesion characteristics, with substantial differences in lesion depth and width observed per unit change in RF time (<xref ref-type="fig" rid="F4">Figure&#x00A0;4B</xref>). Therefore, to fine-tune the ablation lesion while ensuring procedural safety, we prefer to adjust the power output rather than modifying the RF application time. To investigate effects of different impedances on lesions, TTC staining was used to characterize the ablation damage. At 90&#x03A9;, the lesions were the most severe, with coagulative necrosis observed in the center&#x2014;a finding not noted at other impedance values. Specifically, the 90&#x03A9; lesions were clearly demarcated into three distinct regions: (1) a central dark brown zone, (2) a lighter peripheral zone, and (3) normal red myocardial tissue.</p>
</sec>
<sec id="s4b"><label>4.2</label><title>Ablation performance and parameter adjustments across different impedances</title>
<p>When the same power was applied at different impedances, the depth and width of ablated lesions varied significantly. Specifically, as impedance elevated, lesion size decreased; conversely, as impedance decreased, lesion size increased (<xref ref-type="bibr" rid="B25">25</xref>). At low impedance (90&#x03A9;), RF power output should be reduced. In QMODE&#x002B; ablation mode, our study found: (1) ablation parameters of 80&#x2005;W/3&#x2005;s, 80&#x2005;W/4&#x2005;s, and 90&#x2005;W/3&#x2005;s at lower impedance (90&#x03A9;) produced lesion characteristics comparable to those under medium impedance (120&#x03A9;); (2) lesions produced at higher impedance (150&#x03A9;) differed from those under medium impedance (120&#x03A9;). To ensure consistent ablation damage at 150&#x03A9; impedance, we added another set of experiments using QMODE, which found that lesions at AI&#x2009;&#x003D;&#x2009;400/420 (150&#x03A9;) were similar to those in medium impedance QMODE&#x002B; group (120&#x03A9;).</p>
</sec>
</sec>
<sec id="s5"><label>5</label><title>Clinical implications</title>
<p>The effects of different ablation parameters on cardiac tissue damage under QMODE&#x002B; ablation modes were analyzed. This analysis facilitates a better understanding of the ablation characteristics of new ablation modes, thereby guiding clinical procedures more effectively and safely. In particular, the study addresses how to adjust catheter ablation parameters based on varying impedances: energy wattage or ablation duration can be reduced at lower impedance under QMODE&#x002B; ablation mode, and switching to QMODE is recommended at higher impedance. Notably, impedance in this study was modified by adjusting saline concentration and dispersive electrode distance, which does not fully replicate clinical local impedance changes (influenced by tissue properties, catheter contact, and blood flow). Thus, these findings are specific to the experimental setting and require clinical validation.</p>
</sec>
<sec id="s6"><label>6</label><title>Limitations</title>
<p>Like any preclinical experiment, this study was conducted using <italic>in vitro</italic> models, whose biophysical properties may differ from those of humans and from clinical ablation procedures. The <italic>ex vivo</italic> experimental model lacked coronary perfusion and did not account for cardiac or respiratory movements. Additionally, a salt solution was used instead of blood in the tissue bath to facilitate direct visualization of catheter-tissue contact and ensure accurate targeting of ablation sites. The differences in conductivity between the salt solution and blood may have influenced ablation lesion formation. Additional limitations include: (1) Small sample size (5 lesions per group), which limits statistical power for detecting subtle differences, especially for 1&#x2005;mm increment interlesion distance comparisons. (2) Incomplete lesion geometry assessment: RF lesions are typically elliptical, but this study only measured surface width and maximum depth, without quantifying area, volume, or junctional continuity. This restricts comprehensive evaluation of interlesion gap formation.</p>
</sec>
<sec id="s7" sec-type="conclusions"><label>7</label><title>Conclusions</title>
<p>Routine QMODE&#x002B; ablation with 90&#x2005;W power, 4&#x2005;s RF duration, catheter CF &#x003C;25&#x2005;g, 5&#x2005;mm interlesion distance (reference in this <italic>ex vivo</italic> model), and perpendicular contact achieves optimal lesion formation. To ensure consistent damage across different impedances, adjust QMODE&#x002B; parameters at low impedance and switch to QMODE at high impedance. Parallel contact could be preferred at fragile sites or under low impedance to reduce lesion depth and avoid over-damage.</p>
</sec>
</body>
<back>
<sec id="s8" sec-type="data-availability"><title>Data availability statement</title>
<p>The datasets presented in this study can be found in online repositories. The names of the repository/repositories and accession number(s) can be found in the article/<xref ref-type="sec" rid="s14">Supplementary Material</xref>.</p>
</sec>
<sec id="s9" sec-type="ethics-statement"><title>Ethics statement</title>
<p>The article presents research on animals that do not require ethical approval for their study.</p>
</sec>
<sec id="s10" sec-type="author-contributions"><title>Author contributions</title>
<p>XS: Conceptualization, Data curation, Formal analysis, Investigation, Project administration, Software, Validation, Visualization, Writing &#x2013; original draft. MS: Conceptualization, Data curation, Methodology, Resources, Writing &#x2013; review &#x0026; editing. ZW: Project administration, Supervision, Validation, Writing &#x2013; review &#x0026; editing. ML: Investigation, Project administration, Software, Writing &#x2013; review &#x0026; editing. ZJ: Project administration, Visualization, Writing &#x2013; review &#x0026; editing. JD: Resources, Software, Writing &#x2013; review &#x0026; editing.</p>
</sec>
<sec id="s12" sec-type="COI-statement"><title>Conflict of interest</title>
<p>The author(s) declared that this work was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec id="s13" sec-type="ai-statement"><title>Generative AI statement</title>
<p>The author(s) declared that generative AI was not used in the creation of this manuscript.</p>
<p>Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.</p>
</sec>
<sec id="s15" sec-type="disclaimer"><title>Publisher&#x0027;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<sec id="s14" sec-type="supplementary-material"><title>Supplementary material</title>
<p>The Supplementary Material for this article can be found online at: <ext-link ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/fcvm.2026.1743828/full#supplementary-material">https://www.frontiersin.org/articles/10.3389/fcvm.2026.1743828/full&#x0023;supplementary-material</ext-link></p>
<supplementary-material xlink:href="Datasheet1.pdf" id="SM1" mimetype="application/pdf"/>
</sec>
<ref-list><title>References</title>
<ref id="B1"><label>1.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Jilek</surname> <given-names>C</given-names></name> <name><surname>Ullah</surname> <given-names>W</given-names></name></person-group>. <article-title>Pulmonary vein reconnections or substrate in the left atrium: what is the reason for atrial fibrillation recurrences? A dialogue on a pressing clinical situation</article-title>. <source>Europace</source>. (<year>2019</year>) <volume>21</volume>(<issue>1</issue>):<fpage>i12</fpage>&#x2013;<lpage>20</lpage>. <pub-id pub-id-type="doi">10.1093/europace/euy289</pub-id><pub-id pub-id-type="pmid">30801129</pub-id></mixed-citation></ref>
<ref id="B2"><label>2.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ganesan</surname> <given-names>AN</given-names></name> <name><surname>Shipp</surname> <given-names>NJ</given-names></name> <name><surname>Brooks</surname> <given-names>AG</given-names></name> <name><surname>Kuklik</surname> <given-names>P</given-names></name> <name><surname>Lau</surname> <given-names>DH</given-names></name> <name><surname>Lim</surname> <given-names>HS</given-names></name><etal/></person-group> <article-title>Long-term outcomes of catheter ablation of atrial fibrillation: a systematic review and meta-analysis</article-title>. <source>J Am Heart Assoc</source>. (<year>2013</year>) <volume>2</volume>(<issue>2</issue>):<fpage>e004549</fpage>. <pub-id pub-id-type="doi">10.1161/JAHA.112.004549</pub-id><pub-id pub-id-type="pmid">23537812</pub-id></mixed-citation></ref>
<ref id="B3"><label>3.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Macle</surname> <given-names>L</given-names></name> <name><surname>Khairy</surname> <given-names>P</given-names></name> <name><surname>Weerasooriya</surname> <given-names>R</given-names></name> <name><surname>Novak</surname> <given-names>P</given-names></name> <name><surname>Verma</surname> <given-names>A</given-names></name> <name><surname>Willems</surname> <given-names>S</given-names></name><etal/></person-group> <article-title>Adenosine-guided pulmonary vein isolation for the treatment of paroxysmal atrial fibrillation: an international, multicentre, randomised superiority trial</article-title>. <source>Lancet</source>. (<year>2015</year>) <volume>386</volume>(<issue>9994</issue>):<fpage>672</fpage>&#x2013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1016/S0140-6736(15)60026-5</pub-id><pub-id pub-id-type="pmid">26211828</pub-id></mixed-citation></ref>
<ref id="B4"><label>4.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Anter</surname> <given-names>E</given-names></name> <name><surname>Contreras-Valdes</surname> <given-names>FM</given-names></name> <name><surname>Shvilkin</surname> <given-names>A</given-names></name> <name><surname>Tschabrunn</surname> <given-names>CM</given-names></name> <name><surname>Josephson</surname> <given-names>ME</given-names></name></person-group>. <article-title>Acute pulmonary vein reconnection is a predictor of atrial fibrillation recurrence following pulmonary vein isolation</article-title>. <source>J Interv Card Electrophysiol</source>. (<year>2014</year>) <volume>39</volume>(<issue>3</issue>):<fpage>225</fpage>&#x2013;<lpage>32</lpage>. <pub-id pub-id-type="doi">10.1007/s10840-013-9864-9</pub-id><pub-id pub-id-type="pmid">24532109</pub-id></mixed-citation></ref>
<ref id="B5"><label>5.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Wittkampf</surname> <given-names>FH</given-names></name> <name><surname>Nakagawa</surname> <given-names>H</given-names></name></person-group>. <article-title>RF catheter ablation: lessons on lesions</article-title>. <source>Pacing Clin Electrophysiol</source>. (<year>2006</year>) <volume>29</volume>(<issue>11</issue>):<fpage>1285</fpage>&#x2013;<lpage>97</lpage>. <pub-id pub-id-type="doi">10.1111/j.1540-8159.2006.00533.x</pub-id><pub-id pub-id-type="pmid">17100685</pub-id></mixed-citation></ref>
<ref id="B6"><label>6.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Nakagawa</surname> <given-names>H</given-names></name> <name><surname>Jackman</surname> <given-names>WM</given-names></name></person-group>. <article-title>The role of contact force in atrial fibrillation ablation</article-title>. <source>J Atr Fibrillation</source>. (<year>2014</year>) <volume>7</volume>(<issue>1</issue>):<fpage>1027</fpage>. <pub-id pub-id-type="doi">10.4022/jafib.1027</pub-id><pub-id pub-id-type="pmid">27957075</pub-id></mixed-citation></ref>
<ref id="B7"><label>7.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ariyarathna</surname> <given-names>N</given-names></name> <name><surname>Kumar</surname> <given-names>S</given-names></name> <name><surname>Thomas</surname> <given-names>SP</given-names></name> <name><surname>Stevenson</surname> <given-names>WG</given-names></name> <name><surname>Michaud</surname> <given-names>GF</given-names></name></person-group>. <article-title>Role of contact force sensing in catheter ablation of cardiac arrhythmias: evolution or history repeating itself?</article-title> <source>JACC Clin Electrophysiol</source>. (<year>2018</year>) <volume>4</volume>(<issue>6</issue>):<fpage>707</fpage>&#x2013;<lpage>23</lpage>. <pub-id pub-id-type="doi">10.1016/j.jacep.2018.03.014</pub-id><pub-id pub-id-type="pmid">29929663</pub-id></mixed-citation></ref>
<ref id="B8"><label>8.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ullah</surname> <given-names>W</given-names></name> <name><surname>Hunter</surname> <given-names>RJ</given-names></name> <name><surname>Finlay</surname> <given-names>MC</given-names></name> <name><surname>McLean</surname> <given-names>A</given-names></name> <name><surname>Dhinoja</surname> <given-names>MB</given-names></name> <name><surname>Sporton</surname> <given-names>S</given-names></name><etal/></person-group> <article-title>Ablation index and surround flow catheter irrigation: impedance-based appraisal in clinical ablation</article-title>. <source>JACC Clin Electrophysiol</source>. (<year>2017</year>) <volume>3</volume>(<issue>10</issue>):<fpage>1080</fpage>&#x2013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1016/j.jacep.2017.03.011</pub-id><pub-id pub-id-type="pmid">29759489</pub-id></mixed-citation></ref>
<ref id="B9"><label>9.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Yavin</surname> <given-names>HD</given-names></name> <name><surname>Leshem</surname> <given-names>E</given-names></name> <name><surname>Shapira-Daniels</surname> <given-names>A</given-names></name> <name><surname>Sroubek</surname> <given-names>J</given-names></name> <name><surname>Barkagan</surname> <given-names>M</given-names></name> <name><surname>Haffajee</surname> <given-names>CI</given-names></name><etal/></person-group> <article-title>Impact of high-power short-duration radiofrequency ablation on long-term lesion durability for atrial fibrillation ablation</article-title>. <source>JACC Clin Electrophysiol</source>. (<year>2020</year>) <volume>6</volume>(<issue>8</issue>):<fpage>973</fpage>&#x2013;<lpage>85</lpage>. <pub-id pub-id-type="doi">10.1016/j.jacep.2020.04.023</pub-id><pub-id pub-id-type="pmid">32819533</pub-id></mixed-citation></ref>
<ref id="B10"><label>10.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Leshem</surname> <given-names>E</given-names></name> <name><surname>Zilberman</surname> <given-names>I</given-names></name> <name><surname>Tschabrunn</surname> <given-names>CM</given-names></name> <name><surname>Barkagan</surname> <given-names>M</given-names></name> <name><surname>Contreras-Valdes</surname> <given-names>FM</given-names></name> <name><surname>Govari</surname> <given-names>A</given-names></name><etal/></person-group> <article-title>High-power and short-duration ablation for pulmonary vein isolation: biophysical characterization</article-title>. <source>JACC Clin Electrophysiol</source>. (<year>2018</year>) <volume>4</volume>(<issue>4</issue>):<fpage>467</fpage>&#x2013;<lpage>79</lpage>. <pub-id pub-id-type="doi">10.1016/j.jacep.2017.11.018</pub-id><pub-id pub-id-type="pmid">30067486</pub-id></mixed-citation></ref>
<ref id="B11"><label>11.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Leshem</surname> <given-names>E</given-names></name> <name><surname>Zilberman</surname> <given-names>I</given-names></name> <name><surname>Barkagan</surname> <given-names>M</given-names></name> <name><surname>Shapira-Daniels</surname> <given-names>A</given-names></name> <name><surname>Sroubek</surname> <given-names>J</given-names></name> <name><surname>Govari</surname> <given-names>A</given-names></name><etal/></person-group> <article-title>Temperature-controlled radiofrequency ablation using irrigated catheters: maximizing ventricular lesion dimensions while reducing steam-pop formation</article-title>. <source>JACC Clin Electrophysiol</source>. (<year>2020</year>) <volume>6</volume>(<issue>1</issue>):<fpage>83</fpage>&#x2013;<lpage>93</lpage>. <pub-id pub-id-type="doi">10.1016/j.jacep.2019.08.015</pub-id><pub-id pub-id-type="pmid">31971910</pub-id></mixed-citation></ref>
<ref id="B12"><label>12.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Barkagan</surname> <given-names>M</given-names></name> <name><surname>Contreras-Valdes</surname> <given-names>FM</given-names></name> <name><surname>Leshem</surname> <given-names>E</given-names></name> <name><surname>Buxton</surname> <given-names>AE</given-names></name> <name><surname>Nakagawa</surname> <given-names>H</given-names></name> <name><surname>Anter</surname> <given-names>E</given-names></name></person-group>. <article-title>High-power and short-duration ablation for pulmonary vein isolation: safety, efficacy, and long-term durability</article-title>. <source>J Cardiovasc Electrophysiol</source>. (<year>2018</year>) <volume>29</volume>(<issue>9</issue>):<fpage>1287</fpage>&#x2013;<lpage>96</lpage>. <pub-id pub-id-type="doi">10.1111/jce.13651</pub-id><pub-id pub-id-type="pmid">29846987</pub-id></mixed-citation></ref>
<ref id="B13"><label>13.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Reddy</surname> <given-names>VY</given-names></name> <name><surname>Grimaldi</surname> <given-names>M</given-names></name> <name><surname>De Potter</surname> <given-names>T</given-names></name> <name><surname>Vijgen</surname> <given-names>JM</given-names></name> <name><surname>Bulava</surname> <given-names>A</given-names></name> <name><surname>Duytschaever</surname> <given-names>MF</given-names></name><etal/></person-group> <article-title>Pulmonary vein isolation with very high power, short duration, temperature-controlled lesions: the QDOT-FAST trial</article-title>. <source>JACC Clin Electrophysiol</source>. (<year>2019</year>) <volume>5</volume>(<issue>7</issue>):<fpage>778</fpage>&#x2013;<lpage>86</lpage>. <pub-id pub-id-type="doi">10.1016/j.jacep.2019.04.009</pub-id><pub-id pub-id-type="pmid">31320006</pub-id></mixed-citation></ref>
<ref id="B14"><label>14.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ikenouchi</surname> <given-names>T</given-names></name> <name><surname>Takigawa</surname> <given-names>M</given-names></name> <name><surname>Goya</surname> <given-names>M</given-names></name> <name><surname>Martin</surname> <given-names>CA</given-names></name> <name><surname>Yamamoto</surname> <given-names>T</given-names></name> <name><surname>Yamaguchi</surname> <given-names>J</given-names></name><etal/></person-group> <article-title>Comparison of lesion characteristics using temperature-flow-controlled versus conventional power-controlled ablation with fixed ablation index</article-title>. <source>J Cardiovasc Electrophysiol</source>. (<year>2023</year>) <volume>34</volume>(<issue>4</issue>):<fpage>908</fpage>&#x2013;<lpage>17</lpage>. <pub-id pub-id-type="doi">10.1111/jce.15883</pub-id><pub-id pub-id-type="pmid">36906814</pub-id></mixed-citation></ref>
<ref id="B15"><label>15.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Yamaguchi</surname> <given-names>J</given-names></name> <name><surname>Takigawa</surname> <given-names>M</given-names></name> <name><surname>Goya</surname> <given-names>M</given-names></name> <name><surname>Martin</surname> <given-names>CA</given-names></name> <name><surname>Yamamoto</surname> <given-names>T</given-names></name> <name><surname>Ikenouchi</surname> <given-names>T</given-names></name><etal/></person-group> <article-title>Comparison of three different approaches to very high-power short-duration ablation using the QDOT-MICRO catheter</article-title>. <source>J Cardiovasc Electrophysiol</source>. (<year>2023</year>) <volume>34</volume>(<issue>4</issue>):<fpage>888</fpage>&#x2013;<lpage>97</lpage>. <pub-id pub-id-type="doi">10.1111/jce.15875</pub-id><pub-id pub-id-type="pmid">36852902</pub-id></mixed-citation></ref>
<ref id="B16"><label>16.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Verma</surname> <given-names>A</given-names></name> <name><surname>Neal</surname> <given-names>R</given-names></name> <name><surname>Evans</surname> <given-names>J</given-names></name> <name><surname>Castellvi</surname> <given-names>Q</given-names></name> <name><surname>Vachani</surname> <given-names>A</given-names></name> <name><surname>Deneke</surname> <given-names>T</given-names></name><etal/></person-group> <article-title>Characteristics of pulsed electric field cardiac ablation porcine treatment zones with a focal catheter</article-title>. <source>J Cardiovasc Electrophysiol</source>. (<year>2023</year>) <volume>34</volume>(<issue>1</issue>):<fpage>99</fpage>&#x2013;<lpage>107</lpage>. <pub-id pub-id-type="doi">10.1111/jce.15734</pub-id><pub-id pub-id-type="pmid">36335638</pub-id></mixed-citation></ref>
<ref id="B17"><label>17.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Nakagawa</surname> <given-names>H</given-names></name> <name><surname>Castellvi</surname> <given-names>Q</given-names></name> <name><surname>Neal</surname> <given-names>R</given-names></name> <name><surname>Girouard</surname> <given-names>S</given-names></name> <name><surname>Laughner</surname> <given-names>J</given-names></name> <name><surname>Ikeda</surname> <given-names>A</given-names></name><etal/></person-group> <article-title>Effects of contact force on lesion size during pulsed field catheter ablation: histochemical characterization of ventricular lesion boundaries</article-title>. <source>Circ Arrhythm Electrophysiol</source>. (<year>2024</year>) <volume>17</volume>(<issue>1</issue>):<fpage>e012026</fpage>. <pub-id pub-id-type="doi">10.1161/CIRCEP.123.012026</pub-id><pub-id pub-id-type="pmid">38152949</pub-id></mixed-citation></ref>
<ref id="B18"><label>18.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Steiger</surname> <given-names>NA</given-names></name> <name><surname>McClennen</surname> <given-names>L</given-names></name> <name><surname>Bilenker</surname> <given-names>J</given-names></name> <name><surname>Patino</surname> <given-names>C</given-names></name> <name><surname>Matos</surname> <given-names>CD</given-names></name> <name><surname>Sauer</surname> <given-names>KM</given-names></name><etal/></person-group> <article-title>Evaluation of pulsed field ablation lesion characteristics using an <italic>in vitro</italic> vegetable model</article-title>. <source>J Interv Card Electrophysiol</source>. (<year>2024</year>). <pub-id pub-id-type="doi">10.1007/s10840-024-01906-8</pub-id></mixed-citation></ref>
<ref id="B19"><label>19.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ikeda</surname> <given-names>A</given-names></name> <name><surname>Nakagawa</surname> <given-names>H</given-names></name> <name><surname>Lambert</surname> <given-names>H</given-names></name> <name><surname>Shah</surname> <given-names>DC</given-names></name> <name><surname>Fonck</surname> <given-names>E</given-names></name> <name><surname>Yulzari</surname> <given-names>A</given-names></name><etal/></person-group> <article-title>Relationship between catheter contact force and radiofrequency lesion size and incidence of steam pop in the beating canine heart: electrogram amplitude, impedance, and electrode temperature are poor predictors of electrode-tissue contact force and lesion size</article-title>. <source>Circ Arrhythm Electrophysiol</source>. (<year>2014</year>) <volume>7</volume>(<issue>6</issue>):<fpage>1174</fpage>&#x2013;<lpage>80</lpage>. <pub-id pub-id-type="doi">10.1161/CIRCEP.113.001094</pub-id><pub-id pub-id-type="pmid">25381331</pub-id></mixed-citation></ref>
<ref id="B20"><label>20.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Rozen</surname> <given-names>G</given-names></name> <name><surname>Ptaszek</surname> <given-names>L</given-names></name> <name><surname>Zilberman</surname> <given-names>I</given-names></name> <name><surname>Cordaro</surname> <given-names>K</given-names></name> <name><surname>Heist</surname> <given-names>EK</given-names></name> <name><surname>Beeckler</surname> <given-names>C</given-names></name><etal/></person-group> <article-title>Prediction of radiofrequency ablation lesion formation using a novel temperature sensing technology incorporated in a force sensing catheter</article-title>. <source>Heart Rhythm</source>. (<year>2017</year>) <volume>14</volume>(<issue>2</issue>):<fpage>248</fpage>&#x2013;<lpage>54</lpage>. <pub-id pub-id-type="doi">10.1016/j.hrthm.2016.11.013</pub-id><pub-id pub-id-type="pmid">28104089</pub-id></mixed-citation></ref>
<ref id="B21"><label>21.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Tsutsui</surname> <given-names>K</given-names></name> <name><surname>Kawano</surname> <given-names>D</given-names></name> <name><surname>Mori</surname> <given-names>H</given-names></name> <name><surname>Kato</surname> <given-names>R</given-names></name> <name><surname>Ikeda</surname> <given-names>Y</given-names></name> <name><surname>Sumitomo</surname> <given-names>N</given-names></name><etal/></person-group> <article-title>Characteristics and optimal ablation settings of a novel, contact-force sensing and local impedance-enabled catheter in an <italic>ex vivo</italic> perfused swine ventricle model</article-title>. <source>J Cardiovasc Electrophysiol</source>. (<year>2021</year>) <volume>32</volume>(<issue>12</issue>):<fpage>3187</fpage>&#x2013;<lpage>94</lpage>. <pub-id pub-id-type="doi">10.1111/jce.15253</pub-id><pub-id pub-id-type="pmid">34559441</pub-id></mixed-citation></ref>
<ref id="B22"><label>22.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Winkle</surname> <given-names>RA</given-names></name></person-group>. <article-title>HPSD ablation for AF high-power short-duration RF ablation for atrial fibrillation: a review</article-title>. <source>J Cardiovasc Electrophysiol</source>. (<year>2021</year>) <volume>32</volume>(<issue>10</issue>):<fpage>2813</fpage>&#x2013;<lpage>23</lpage>. <pub-id pub-id-type="doi">10.1111/jce.14863</pub-id><pub-id pub-id-type="pmid">33382506</pub-id></mixed-citation></ref>
<ref id="B23"><label>23.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Yamaguchi</surname> <given-names>J</given-names></name> <name><surname>Takigawa</surname> <given-names>M</given-names></name> <name><surname>Goya</surname> <given-names>M</given-names></name> <name><surname>Martin</surname> <given-names>CA</given-names></name> <name><surname>Negishi</surname> <given-names>M</given-names></name> <name><surname>Yamamoto</surname> <given-names>T</given-names></name><etal/></person-group> <article-title>Impact of contact force on the lesion characteristics of very high-power short-duration ablation using a QDOT-MICRO catheter</article-title>. <source>J Arrhythm</source>. (<year>2024</year>) <volume>40</volume>(<issue>2</issue>):<fpage>247</fpage>&#x2013;<lpage>55</lpage>. <pub-id pub-id-type="doi">10.1002/joa3.12992</pub-id><pub-id pub-id-type="pmid">38586837</pub-id></mixed-citation></ref>
<ref id="B24"><label>24.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Bortone</surname> <given-names>AA</given-names></name> <name><surname>Ramirez</surname> <given-names>FD</given-names></name> <name><surname>Constantin</surname> <given-names>M</given-names></name> <name><surname>Bortone</surname> <given-names>C</given-names></name> <name><surname>H&#x00E9;bert</surname> <given-names>C</given-names></name> <name><surname>Constantin</surname> <given-names>J</given-names></name><etal/></person-group> <article-title>Optimal interlesion distance for 90 and 50 watt radiofrequency applications with low ablation index values: experimental findings in a chronic ovine model</article-title>. <source>Europace</source>. (<year>2023</year>) <volume>25</volume>(<issue>11</issue>):<fpage>euad310</fpage>. <pub-id pub-id-type="doi">10.1093/europace/euad310</pub-id><pub-id pub-id-type="pmid">37851513</pub-id></mixed-citation></ref>
<ref id="B25"><label>25.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Bourier</surname> <given-names>F</given-names></name> <name><surname>Ramirez</surname> <given-names>FD</given-names></name> <name><surname>Martin</surname> <given-names>CA</given-names></name> <name><surname>Vlachos</surname> <given-names>K</given-names></name> <name><surname>Frontera</surname> <given-names>A</given-names></name> <name><surname>Takigawa</surname> <given-names>M</given-names></name><etal/></person-group> <article-title>Impedance, power, and current in radiofrequency ablation: insights from technical, <italic>ex vivo</italic>, and clinical studies</article-title>. <source>J Cardiovasc Electrophysiol</source>. (<year>2020</year>) <volume>31</volume>(<issue>11</issue>):<fpage>2836</fpage>&#x2013;<lpage>45</lpage>. <pub-id pub-id-type="doi">10.1111/jce.14709</pub-id><pub-id pub-id-type="pmid">32757434</pub-id></mixed-citation></ref></ref-list>
<fn-group>
<fn id="n1" fn-type="custom" custom-type="edited-by"><p>Edited by: <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1030313/overview">Rui Providencia</ext-link>, University College London, United Kingdom</p></fn>
<fn id="n2" fn-type="custom" custom-type="reviewed-by"><p>Reviewed by: <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/3325039/overview">Yuichi Hanaki</ext-link>, Leiden University, Netherlands</p>
<p><ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/3330998/overview">Morio Ono</ext-link>, Kikuna Memorial Hospital, Japan</p></fn>
</fn-group>
<fn-group>
<fn fn-type="abbr" id="abbrev1"><p><bold>Abbreviations</bold> RF, radio frequency; AF, atrial fibrillation; PVI, pulmonary vein isolation.</p></fn>
</fn-group>
</back>
</article>