<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3-mathml3.dtd">
<article article-type="research-article" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:ali="http://www.niso.org/schemas/ali/1.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" dtd-version="1.3" xml:lang="EN">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Cardiovasc. Med.</journal-id>
<journal-title-group>
<journal-title>Frontiers in Cardiovascular Medicine</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Cardiovasc. Med.</abbrev-journal-title>
</journal-title-group>
<issn pub-type="epub">2297-055X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fcvm.2025.1600695</article-id>
<article-version article-version-type="Version of Record" vocab="NISO-RP-8-2008"/>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Original Research</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Rapid diagnosis of different cardiovascular disease events from early released cardiac biomarkers, cTnI, BNP, and CRP, by biosensor technology</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name><surname>Ullah</surname><given-names>Razi</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/2748511/overview"/>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="conceptualization" vocab-term-identifier="https://credit.niso.org/contributor-roles/conceptualization/">Conceptualization</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="methodology" vocab-term-identifier="https://credit.niso.org/contributor-roles/methodology/">Methodology</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="validation" vocab-term-identifier="https://credit.niso.org/contributor-roles/validation/">Validation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="investigation" vocab-term-identifier="https://credit.niso.org/contributor-roles/investigation/">Investigation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="resources" vocab-term-identifier="https://credit.niso.org/contributor-roles/resources/">Resources</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Data curation" vocab-term-identifier="https://credit.niso.org/contributor-roles/data-curation/">Data curation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; original draft" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-original-draft/">Writing &#x2013; original draft</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &amp; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-review-editing/">Writing &#x2013; review &amp; editing</role></contrib>
<contrib contrib-type="author">
<name><surname>Khan</surname><given-names>Mubassir</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<uri xlink:href="https://loop.frontiersin.org/people/860065/overview" />
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="conceptualization" vocab-term-identifier="https://credit.niso.org/contributor-roles/conceptualization/">Conceptualization</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="methodology" vocab-term-identifier="https://credit.niso.org/contributor-roles/methodology/">Methodology</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="validation" vocab-term-identifier="https://credit.niso.org/contributor-roles/validation/">Validation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="investigation" vocab-term-identifier="https://credit.niso.org/contributor-roles/investigation/">Investigation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Data curation" vocab-term-identifier="https://credit.niso.org/contributor-roles/data-curation/">Data curation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &amp; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-review-editing/">Writing &#x2013; review &amp; editing</role></contrib>
<contrib contrib-type="author" corresp="yes">
<name><surname>Huang</surname><given-names>Yin</given-names></name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<xref ref-type="corresp" rid="cor1">&#x002A;</xref>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="conceptualization" vocab-term-identifier="https://credit.niso.org/contributor-roles/conceptualization/">Conceptualization</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="methodology" vocab-term-identifier="https://credit.niso.org/contributor-roles/methodology/">Methodology</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="validation" vocab-term-identifier="https://credit.niso.org/contributor-roles/validation/">Validation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Formal analysis" vocab-term-identifier="https://credit.niso.org/contributor-roles/formal-analysis/">Formal analysis</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="investigation" vocab-term-identifier="https://credit.niso.org/contributor-roles/investigation/">Investigation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="resources" vocab-term-identifier="https://credit.niso.org/contributor-roles/resources/">Resources</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Data curation" vocab-term-identifier="https://credit.niso.org/contributor-roles/data-curation/">Data curation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &amp; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-review-editing/">Writing &#x2013; review &amp; editing</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Funding acquisition" vocab-term-identifier="https://credit.niso.org/contributor-roles/funding-acquisition/">Funding acquisition</role></contrib>
<contrib contrib-type="author" corresp="yes">
<name><surname>Wang</surname><given-names>Guixue</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="corresp" rid="cor1">&#x002A;</xref>
<uri xlink:href="https://loop.frontiersin.org/people/804728/overview"/>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="conceptualization" vocab-term-identifier="https://credit.niso.org/contributor-roles/conceptualization/">Conceptualization</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="methodology" vocab-term-identifier="https://credit.niso.org/contributor-roles/methodology/">Methodology</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Formal analysis" vocab-term-identifier="https://credit.niso.org/contributor-roles/formal-analysis/">Formal analysis</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="resources" vocab-term-identifier="https://credit.niso.org/contributor-roles/resources/">Resources</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Data curation" vocab-term-identifier="https://credit.niso.org/contributor-roles/data-curation/">Data curation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &amp; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-review-editing/">Writing &#x2013; review &amp; editing</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Funding acquisition" vocab-term-identifier="https://credit.niso.org/contributor-roles/funding-acquisition/">Funding acquisition</role>
</contrib>
</contrib-group>
<aff id="aff1"><label>1</label><institution>Key Laboratory for Biorheological Science and Technology of Ministry of Education, National Local Joint Engineering Lab for Vascular Implants, College of Bioengineering, Chongqing University</institution>, <city>Chongqing</city>, <country country="cn">China</country></aff>
<aff id="aff2"><label>2</label><institution>Institute of Panvascular Biology, Jin Feng Laboratory</institution>, <city>Chongqing</city>, <country country="cn">China</country></aff>
<aff id="aff3"><label>3</label><institution>Department of Gastrointestinal Surgery, The First Affiliated Hospital of Chongqing Medical University</institution>, <city>Chongqing</city>, <country country="cn">China</country></aff>
<author-notes>
<corresp id="cor1"><label>&#x002A;</label><bold>Correspondence:</bold> Guixue Wang <email xlink:href="mailto:wanggx@cqu.edu.cn">wanggx@cqu.edu.cn</email> Yin Huang <email xlink:href="mailto:248244642@qq.com">248244642@qq.com</email></corresp>
</author-notes>
<pub-date publication-format="electronic" date-type="pub" iso-8601-date="2025-12-17"><day>17</day><month>12</month><year>2025</year></pub-date>
<pub-date publication-format="electronic" date-type="collection"><year>2025</year></pub-date>
<volume>12</volume><elocation-id>1600695</elocation-id>
<history>
<date date-type="received"><day>01</day><month>04</month><year>2025</year></date>
<date date-type="accepted"><day>22</day><month>09</month><year>2025</year></date>
</history>
<permissions>
<copyright-statement>&#x00A9; 2025 Ullah, Khan, Huang and Wang.</copyright-statement>
<copyright-year>2025</copyright-year><copyright-holder>Ullah, Khan, Huang and Wang</copyright-holder><license><ali:license_ref start_date="2025-12-17">https://creativecommons.org/licenses/by/4.0/</ali:license_ref>
<license-p>This is an open-access article distributed under the terms of the <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">Creative Commons Attribution License (CC BY)</ext-link>. The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</license-p></license>
</permissions>
<abstract>
<p>Cardiovascular disease (CVD) represents a significant global health challenge, making the detection of cardiac biomarkers crucial for early diagnosis and tailored treatment strategies. This research aims to transpire a point-of-care (POC) test using a biosensor for CVDs that will be fast and pragmatic for immediate use in acute and resource-constrained environments. Traditional techniques such as enzyme-linked immunosorbent assay and polymerase chain reaction, although very precise, are time-consuming, labor intensive, and not suitable for use in urgent care; however, optical nano biosensors provide rapid, highly selective, and sensitive detection capabilities. The optical nano biosensors produce biological signals that convey light signals as analytes interact with bioreceptors. Optical nano biosensors offer various benefits, including effortless monitoring, inexpensiveness, a broad detection spectrum, and excellent sensitivity with no interference. An optical nano biosensor platform represents an effective method for point-of-care detection of cardiac biomarkers, characterized by a low detection limit. To propose a realistic reference, this study assesses a prompt POC test, which identifies important cardiac biomarkers, such as cardiac troponins (cTnI), B-type natriuretic peptide (BNP), and C-reactive protein (CRP), which together provide an all-encompassing confinement of myocardial injury, cardiac stress, and inflammation. Subsequently, the test was performed using a random patient population; the accuracy of the test was established to be high in terms of both sensitivity (95.2&#x0025; for cTnI, 91.8&#x0025; for BNP, and 89&#x0025; for CRP) and specificity and had a close correlation with laboratory tests. It provided results in 15&#x2005;min, which makes it effectively useful when used in emergency and primary care, where quick decisions are required to be taken. The low cost and rapidity of the test increase its applicability notably; this multiplexing allows clinicians to identify individuals at high risk for different CVD events. This work highlights the possibility of incorporating biosensor technology into diagnostic systems at the POC level to enhance patient prognosis by facilitating early interventions and establishes a basis for improving biomarker detection.</p>
</abstract>
<abstract abstract-type="graphical"><title>Graphical Abstract</title>
<p>
<fig position="anchor">
<graphic xlink:href="fcvm-12-1600695-g008.tif" position="anchor"><alt-text content-type="machine-generated">Circular infographic titled "Cardiac Biomarkers" showing three segments. CRP in red represents C-reactive protein, a marker for inflammation with 89% detection. cTnI in yellow denotes cardiac troponin I, indicating myocardial damage with 95.2% detection. BNP in orange shows B-type natriuretic peptide, a marker of cardiac stress with 91.8% detection. Each section is color-coded and paired with an icon and short descriptive text.</alt-text>
</graphic>
</fig></p>
</abstract>
<kwd-group>
<kwd>point-of-care</kwd>
<kwd>cardiovascular diseases</kwd>
<kwd>cardiac failure</kwd>
<kwd>cardiac troponins I (cTnI)</kwd>
<kwd>B type natriuretic peptide (BNP)</kwd>
<kwd>C-reactive protein (CRP)</kwd>
</kwd-group><funding-group>
<funding-statement>The author(s) declare that financial support was received for the research and/or publication of this article. This work was supported by the National Natural Science Foundation of China (No. 12032007, No. 12302406), the Science and Technology Innovation Project of JinFeng Laboratory, Chongqing, China (No. jfkyjf202203001), and the Fundamental Research Funds for the Central Universities (No. 2024CDJCGJ-016).</funding-statement>
</funding-group>
<counts>
<fig-count count="7"/>
<table-count count="2"/><equation-count count="0"/><ref-count count="58"/><page-count count="15"/><word-count count="1110"/></counts><custom-meta-group><custom-meta><meta-name>section-at-acceptance</meta-name><meta-value>General Cardiovascular Medicine</meta-value></custom-meta></custom-meta-group>
</article-meta>
</front>
<body><sec id="s1"><title>Highlights</title>
<list list-type="bullet">
<list-item>
<p>In our study, B-type natriuretic peptide ( diagnoses heart failure, C-reactive protein diagnoses systemic inflammation, and cTnI diagnoses myocardial infarction (the highest AUC&#x2009;&#x003D;&#x2009;0.94).</p></list-item>
<list-item>
<p>Rapid tests are quick and cost-effective, whereas enzyme-linked immunosorbent assay is accurate but laborious for cardiovascular disease diagnosis such as fatal disease detection.</p></list-item>
<list-item>
<p>This study introduces quick biosensor technology as a transformative solution for swift and cost-effective cardiovascular disease diagnosis.</p></list-item>
<list-item>
<p>The study provides a definitive framework for enhancing diagnostic strategies through the equilibrium of accuracy, efficiency, and economic viability.</p></list-item>
</list>
</sec>
<sec id="s2" sec-type="intro"><label>1</label><title>Introduction</title>
<p>Cardiovascular diseases (CVDs) remain the greatest killer ailment profiles, accounting for about 31 &#x0025; of all global fatalities (<xref ref-type="bibr" rid="B1">1</xref>). Their high incidence requires that diagnostic tools be developed to facilitate quick and accurate diagnosis of disease progression, particularly in patients with acute conditions such as MI and heart failure. Because time-critical conditions are characterized by better prognosis, early diagnosis is essential for improving patient well-being and reducing healthcare cost (<xref ref-type="bibr" rid="B2">2</xref>). The contemporary challenge in current clinical practice is the identification of early stages of CVD, which can be addressed by detecting specific biomarkers in blood. Key biomarkers such as cardiac troponins (cTnI), B-type natriuretic peptide (BNP), and C-reactive protein (CRP) serve as important indicators of cardiac stress and injury, making them crucial for identifying patients at risk of adverse cardiac events (<xref ref-type="bibr" rid="B3">3</xref>, <xref ref-type="bibr" rid="B4">4</xref>).</p>
<p>Cardiac troponins, especially troponin I and troponin T, have emerged as the gold-standard biomarkers for detecting myocardial injury over the last few decades (<xref ref-type="bibr" rid="B5">5</xref>). These protein markers show specificity to cardiac tissue and are released into the bloodstream following myocardial cell damage, making them useful in the diagnosis of AMI. Elevated troponin values measured early after the onset of chest pain are strongly suggestive of MI, even when the ECG findings are inconclusive (<xref ref-type="bibr" rid="B6">6</xref>). However, prior conventional techniques for quantifying cardiac biomarkers, including enzyme-linked immunosorbent assay (ELISA) and polymerase chain reaction (PCR), have several limitations, which involve complex procedures, require highly qualified personnel, and time-consuming (<xref ref-type="bibr" rid="B7">7</xref>).</p>
<p>The limitations of conventional diagnostic methods, which are generally performed in centralized laboratories, have driven the demand for rapid, easy-to-use, and portable point-of-care (POC) diagnostic instruments. These devices are intended to provide faster and more accurate results than established methods while also being scalable to areas with limited resource accessibility. Some rapid POC technologies, such as lateral flow immunoassays and biosensor-based systems, have been found to reduce the time spent on diagnosis, which increases the clinical management of patients (<xref ref-type="bibr" rid="B8">8</xref>). Studies on lateral flow assays for the detection of cardiac troponin reveal that these tests can be completed in less than 15 min, making them suitable for use in emergency room and primary care settings (<xref ref-type="bibr" rid="B9">9</xref>). Furthermore, the integration of microfluidic technology with biosensors has enabled the miniaturization of rapid diagnostic tests, enhancing both their sensitivity and specificity. These advanced platforms can be designed to detect several cardiac biomarkers simultaneously to obtain valuable information about the condition of cardiac muscle tissue (<xref ref-type="bibr" rid="B10">10</xref>).</p>
<p>Another issue is the function of BNP and NT-proBNP, which are natriuretic peptide secretions released in response to ventricular wall tension. These biomarkers have emerged as indicators of early heart failure and other CVDs (<xref ref-type="bibr" rid="B11">11</xref>). High BNP levels prove useful in diagnosing chronic heart failure, and several investigations support their diagnostic and prognostic significance in patients presenting with symptoms such as dyspnea. Rapid assays for BNP and NT-proBNP have also been proven to reduce hospital admissions, as they enable timely identification and early management of patients suspected of having heart failure (<xref ref-type="bibr" rid="B12">12</xref>). Previous studies have demonstrated that the major biomarkers include troponins and natriuretic peptides; however, recent studies suggest that a composite biomarker approach can enhance the outcome of diagnostic prognosis and prediction of additional CVDs (<xref ref-type="bibr" rid="B13">13</xref>).</p>
<p>Novel biomarkers, such as GDF-15, high-sensitivity CRP, and soluble ST2, are increasingly recognized for their role in inflammation and cardiac remodeling, making them useful for both risk assessment and diagnosis of CVDs (<xref ref-type="bibr" rid="B14">14</xref>). It has been established that elevated levels of these markers are associated with higher risks of heart failure, cardiovascular mortality, and all-cause death, especially among patients with lifestyle-related chronic CVDs or those identified as high-risk candidates for future cardiovascular complications (<xref ref-type="bibr" rid="B15">15</xref>). Incorporating these new biomarkers into rapid and portable POC diagnostic technologies might improve early detection and risk stratification of cardiovascular diseases, as well as the overall characterization of a patient&#x0027;s cardiovascular state.</p>
<p>Despite significant advancements, several challenges remain in developing diagnostically useful biomarkers for CVDs with high sensitivity and high specificity. Detecting biomarkers at low concentrations is very important for identifying early-stage disease or minimal myocardial injury, where even a single false-negative result could delay appropriate treatment and negatively affect patient outcomes (<xref ref-type="bibr" rid="B16">16</xref>). Conversely, low specificity of rapid diagnostic tests contributes to raising false-positive results, which may lead to additional invasive procedures and elevate healthcare costs. Thus, the optimization of the relationship between sensitivity and specificity in rapid diagnostic technologies (RDTs) is critical to ensure quick and efficient diagnosis of many widespread diseases (<xref ref-type="bibr" rid="B17">17</xref>).</p>
<p>Recent advancements in biosensor technology, including electrochemical and optical biosensors, have significantly enhanced the sensitivity of POC devices used for detecting cardiac biomarkers (<xref ref-type="bibr" rid="B18">18</xref>). These biosensors are capable of identifying low concentrations of biomarkers in saliva, urine, or blood, enabling accessible and non-invasive screening for CVDs. Further, progress in nanotechnology has led to the development of materials that facilitate interaction between biomarkers and biosensor surfaces, further improving test efficiency and shortening the time required for biomarker detection (<xref ref-type="bibr" rid="B19">19</xref>).</p>
<p>Lateral flow immunoassays (LFIAs) are paper-based point-of-care diagnostic tools that efficiently and cost-effectively identify target analytes, in alignment with the WHO ASSURED criteria. Despite their widespread use in clinical diagnostics, food safety, and environmental monitoring (with the LFIA market expected to reach &#x0024;20.5 billion by 2022 and &#x0024;22.6 billion by 2027), conventional lateral flow immunoassays (LFIAs) often suffer from low sensitivity, resulting in false-negative outcomes when detecting low-abundance biomarkers (10<sup>&#x2212;16</sup> to 10<sup>&#x2212;16</sup> M in cancers and infectious diseases). This limitation highlights the need for next-generation solutions with lower detection limits (<xref ref-type="bibr" rid="B20">20</xref>&#x2013;<xref ref-type="bibr" rid="B27">27</xref>). Antibody orientation, the use of aptamers and glycans, CRISPR integration, optimization of flow dynamics, and specialized readers have been used to improve sensitivity. Instead of primary labels, nanoparticle-assisted signal amplification uses polystyrene beads, silica nanoparticles, or magnetic nanoparticles to enhance labels (e.g., Eu(III) chelates, quantum dots) or to pre-concentrate analytes. Achieving optimal transport dynamics, reaction kinetics, and signal production requires precise engineering of nanoparticle size and surface chemistry (<xref ref-type="bibr" rid="B20">20</xref>, <xref ref-type="bibr" rid="B28">28</xref>&#x2013;<xref ref-type="bibr" rid="B30">30</xref>).</p>
<p>LFIAs use nanoparticles as biomarkers and biosensors. Acting as signal amplifiers and nanocarriers, they enable the dectection of low-abundance analytes with high sensitivity. Polystyrene nanoparticles can capture fluorescent labels like quantum dots and AIEgens through swelling, emulsification, or polymerization processes,. Such nanoparticles can detect targets like SARS-CoV-2 IgM/IgG antibodies at earlier stages than conventional colloidal gold-based LFIAs (LOD: 0.125&#x2013;0.236 &#x03BC;g/mL) (<xref ref-type="bibr" rid="B28">28</xref>).</p>
<p>Silica nanoparticles offer tunable porosity. Nonporous silica nanoparticles can adsorb labels (e.g., PEI-coated QDs for influenza detection at 5 pg/mL), while mesoporous silica nanoparticles (MSNs, &#x003C;10 nm) can encapsulate small-molecule dyes (e.g., Ru(bpy)<sup>32&#x002B;</sup>-loaded MSNs for cardiac troponin I detection at 0.81 pg/mL). Dendritic MSNs (DMSNs) with radial pores can accommodate larger biomolecules or nanoparticles (<xref ref-type="bibr" rid="B20">20</xref>, <xref ref-type="bibr" rid="B31">31</xref>&#x2013;<xref ref-type="bibr" rid="B35">35</xref>).</p>
<p>Fe<sub>3</sub>O<sub>4</sub> MNPs can concentrate target analytes and serve as catalytic or plasmonic labels (SARS-CoV-2 spike antigen detection at 0.5 pg/mL). Gold nanoparticles (AuNPs) facilitate fluorescence activation (influenza nucleoprotein detection at 0.52 pg/mL) and can act as plasmonic carriers (<xref ref-type="bibr" rid="B28">28</xref>).</p>
<p>MOFs and carbon-based nanomaterials, including graphene oxide-based SERS platforms, enable identification of various pathogens at concentrations as low as 9 cells/mL. Optimizing LFIA performance requires careful control over nanoparticle size (138&#x2013;471 nm DMSNs to balance label loading and diffusion) and surface chemistry (carboxylation improves dispersibility, zwitterionic ligands decrease non-specific binding, and directed antibody conjugation for specificity). Maintaining nanoparticle stability (such as preventing MOF hydrolysis), ensuring batch-to-batch consistency, lowering costs, and minimizing false positives, all while pushing detection limits to sub-picomolar levels, remain challenging (<xref ref-type="bibr" rid="B20">20</xref>, <xref ref-type="bibr" rid="B28">28</xref>&#x2013;<xref ref-type="bibr" rid="B31">31</xref>).</p>
<p>Biosensors differ from traditional diagnostic tools in that they convert biological interactions into quantifiable signals, enabling fast detection with minimal sample preparation. Gopal et al. (<xref ref-type="bibr" rid="B36">36</xref>) reveiewed electrochemical (impedance-based, capacitive, potentiometric, and amperometric), mechanical, optical, and colorimetric systems for bacterial detection. Their findings showed that these platforms can detect bacteria in phosphate-buffered saline and milk samples at concentrations ranging from 1 to 845 CFU/mL (<xref ref-type="bibr" rid="B36">36</xref>). Liquid biopsy-based biosensors designed for early cancer diagnosis and treatment monitoring provide quick, minimally invasive analysis using small blood volumes. While the authors describe these processes as &#x201C;physical and biochemical methods&#x201D; to generate digital outputs, they do not provide mechanistic details (<xref ref-type="bibr" rid="B37">37</xref>).</p>
<p>Another study compared biosensors with conventional methods such as culture, polymerase chain reaction, immunoassays, and immunohistochemistry. Traditional methods require long processing times (hours to days), complex sample management, and specialized equipment or knowledge. In contrast, biosensors enable quick detection, require minimal sample preparation, and can be integrated with microfluidic systems and smartphone-based platforms, distinguishing them from traditional diagnostics (<xref ref-type="bibr" rid="B38">38</xref>).</p>
<p>Therefore, the current study seeks to design and assess a rapid diagnostic test capable of diagnosing early cardiac biomarkers with high sensitivity and specificity. Through the optimization of current developments in biosensor and biomarker research, this study aims to improve the above-discussed approaches, ultimately contributing to the development of cost-effective methods for the early identification of CVDs. This work adds to the existing literature on point-of-care diagnostics and can play a significant role in decreasing the burden of CVDs through effective testing solutions.</p>
</sec>
<sec id="s3"><label>2</label><title>Methodology</title>
<sec id="s3a"><label>2.1</label><title>Study design</title>
<p>The study utilized experimental research design that aimed at investigating and developing a rapid POC diagnostic test specifically to detect cardiac biomarkers relevant to early diagnosis of myocardial injury and cardiovascular stress. The approach was designed to assess the usefulness of the test in identifying specific biomarkers, such as cTnI, BNP, and CRP, which are relevant to heart diseases. This was performed in a way that gradually introduced changes to assay performance while testing the sample population that was chosen to cover the possible range of cardiac health status.</p>
</sec>
<sec id="s3b"><label>2.2</label><title>Sample population and ethical considerations</title>
<p>The study was done on sera and plasma from a cross section of apparently healthy patients and of those admitted with suspected acute myocardial infarction and heart failure. Because determining the subjects&#x0027; age difference correlates with the levels of the cardiac biomarkers, the patients&#x0027; inclusion criteria had to consider those who were 30&#x2013;80 years of age. The samples were collected from different hospitals (Shifa International Hospital Islamabad, Rahman Medical Complex Peshawar) and clinical laboratories in Pakistan after receiving administrative approval from institutional review boards the participant medical centers. All participants gave their informed consent in compliance with the samples&#x2019; ethical standards provided by the Declaration of Helsinki for medical research on human beings.</p>
</sec>
<sec id="s3c"><label>2.3</label><title>Biomarker selection and rationale</title>
<p>For the purposes of this study, three protein biomarkers, namely cTnI, BNP, and CRP, were deemed relevant to the diagnosis of acute and chronic cardiovascular diseases like atherosclerosis. Rationally and theoretically, cTnI is a highly specific biomarker of myocardial damage, because any elevation in its levels suggests myocardial infarction (<xref ref-type="bibr" rid="B5">5</xref>). Plasma BNP, in addition to traditional, ventricular stress&#x2013;based measures of heart failure, was also used as an index for even probable ancillary cardiac function and future heart failure (<xref ref-type="bibr" rid="B11">11</xref>). CRP was included because of its recognized correlation with the risk and progression of cardiovascular disease (<xref ref-type="bibr" rid="B15">15</xref>). It was first anticipated that integrating CRP with additional indicators in a quick test method may facilitate a comprehensive evaluation of cardiovascular health.</p>
</sec>
<sec id="s3d"><label>2.4</label><title>Test development procedure</title>
<p>It was the synthesis of LFIA technology and colorimetric detection as shown in the <xref ref-type="fig" rid="F1">Figure 1</xref> that led to the development of the rapid test. Optical signals emerged because anti-cTnI, anti-BNP, and anti-CRP were labeled to various regions of the nitrocellulose membrane on the LFIA strip. Secondary antibodies in the form of gold nanoparticles were collected in tubes placed on the sample pad of the test strip called SF or P. The biomarker-antibody complexes migrated through the strip by capillary action, and upon reaching the fields of capture antibodies, generated toned bands for the visual determination of the results. Lastly, by adjusting an appropriate quantity of conjugates and other test parameters and/or reagent, for example flow rate, the degree of conjugation of the antibody was optimized to an optimal state, enabling rapid detection within 15&#x2005;min.</p>
<fig id="F1" position="float"><label>Figure&#x00A0;1</label>
<caption><p>LFIA/Colorimetric Detection Synthesis: <bold>(a)</bold> LFIA/Colorimetric Detection Synthesis Using paper-based chromatography and nanoparticle labels (e.g., gold nanoparticles), lateral flow immunoassay (LFIA) with colorimetric signal detection allows quick visual readouts. <bold>(b)</bold> Labeling Antibodies Target biomarker antibodies (cTnI, CRP, and BNP) are coupled to signal-generating labels (colloidal gold, latex beads) to produce mobile detection complexes. <bold>(c)</bold> Complex migration via capillaries, biomarker-labeled antibody complexes move along the strip to the test zone. <bold>(d)</bold> Antibody&#x2013;Capture Interaction. The test line&#x0027;s immobilized capture antibodies form a sandwich immunocomplex with biomarker-labeled complexes to localize the signal. <bold>(e)</bold> Band Making Biomarker concentration determines the strength of colorful bands formed by tagged complexes at the test/control lines. <bold>(f)</bold> Parameter optimization. Calibration of antibody quantity, membrane porosity, and velocity optimizes sensitivity, specificity, and signal clarity.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fcvm-12-1600695-g001.tif"><alt-text content-type="machine-generated">Flowchart titled "Rapid Test Development Process" with six sequential steps, each marked by a letter and colored icon. (a) Synthesis of LFIA and colorimetric detection in blue describes combining technologies for rapid testing. (b) Labeling antibodies in teal involves applying labels to antibodies. (c) Migration of complexes in green depicts biomarker-antibody movement along the strip. (d) Capture antibody interaction in yellow shows complex binding to capture antibodies. (e) Band formation in orange indicates visual result detection. (f) Optimization of parameters in red represents adjusting test settings for performance.</alt-text>
</graphic>
</fig>
</sec>
<sec id="s3e"><label>2.5</label><title>Analytical sensitivity and specificity assessment</title>
<p>The calibration and analytical interference of the rapid test were assessed by running samples with a standard concentration of each biomarker according to the guidelines for assay validation as mentioned by Apple et al. (<xref ref-type="bibr" rid="B7">7</xref>). Dilutions of biomarker standards were made in a 1:10 serial fashion to establish the range of detection for the three biomarkers, cTnI, BNP, and CRP. Thus, various types of non-target proteins and other molecules were tested in the described test system and the rate of false positives recorded in repeated trials was calculated statistically. Here, selectivity of the test was operationalized as the ability of the test to identify the target biomarkers, while having minimal detectable affinity with other plasma proteins.</p>
</sec>
<sec id="s3f"><label>2.6</label><title>Clinical affordability and competitive assessment</title>
<p>To clinically validate the rapid test, the strip was compared with laboratory standards that include ELISA commonly used in cTnI and BNP testing together with CRP. Rapid test and comparator assays were used on the sera of 150 individuals with confirmed or suspected CVD conditions to match the invented test against the standard requirements of sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). The level of consistency between the rapid test and other conventional tests was determined using a Cohen&#x0027;s kappa statistic. The accuracy of the diagnostic tests was again verified by calculating the receiver operating characteristic (ROC) curve in a real-life situation.</p>
</sec>
<sec id="s3g"><label>2.7</label><title>Data analysis</title>
<p>A statistical analysis of sensitivity and specificity results obtained from isolated bacterial assays, together with comparative evaluations against standard diagnostic procedures, was undertaken by employing the Statistical Package for the Social Sciences (SPSS). Descriptive statistics were employed to encapsulate the essential distribution properties of biomarkers in all the study groups. The diagnostic efficacy of the fast test was evaluated by ROC analysis, with the area under the curve (AUC) determined for each biomarker. AUC values of 0.80 or higher were deemed indicative of dependable diagnostic accuracy. The ideal cutoff value for clinical application was established by assessing the test&#x0027;s overall sensitivity, specificity, PPV, and NPV. In all statistical studies, a <italic>p</italic>-value of less than 0.05 was deemed statistically significant at a 95&#x0025; confidence interval.</p>
</sec>
<sec id="s3h"><label>2.8</label><title>Limitations and quality control</title>
<p>Realizing the possibility of systematic bias, the study included several measures to minimize variability and improve assay quality. High-quality antiserum and antigens remained active in the test kits within standardized conditions that were maintained to avoid deterioration of reagents. All samples of an assay batch contained control samples with known biomarker concentrations to determine batch to batch variation. Furthermore, repeat tests were prepared to ensure the accuracy of results in a different ambient environment to consider factors such as temperature and humidity that could affect LFIA performance.</p>
</sec>
</sec>
<sec id="s4" sec-type="results"><label>3</label><title>Results</title>
<sec id="s4a"><label>3.1</label><title>Baseline characteristics of the study population</title>
<p>The baseline characteristics of the study population included demographic variables and common risk factors such as hypertension, diabetes, and smoking history. The study sample consisted of 200 participants, subdivided into four groups based on cardiovascular health status: asymptomatic, suspected CVD, confirmed MI, and heart failure <xref ref-type="table" rid="T1">Table&#x00A0;1</xref> provides the details.</p>
<table-wrap id="T1" position="float"><label>Table&#x00A0;1</label>
<caption><p>Baseline characteristics of the study population.</p></caption>
<table>
<thead>
<tr>
<th valign="top" align="left">Variable</th>
<th valign="top" align="center">Total (<italic>N</italic>&#x2009;&#x003D;&#x2009;200)</th>
<th valign="top" align="center">Asymptomatic (<italic>N</italic>&#x2009;&#x003D;&#x2009;50)</th>
<th valign="top" align="center">Suspected CVD (<italic>N</italic>&#x2009;&#x003D;&#x2009;60)</th>
<th valign="top" align="center">Confirmed MI (<italic>N</italic>&#x2009;&#x003D;&#x2009;40)</th>
<th valign="top" align="center">Heart failure (<italic>N</italic>&#x2009;&#x003D;&#x2009;50)</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Age (years, mean&#x2009;&#x00B1;&#x2009;SD)</td>
<td valign="top" align="center">58.6&#x2009;&#x00B1;&#x2009;13.4</td>
<td valign="top" align="center">54.2&#x2009;&#x00B1;&#x2009;12.3</td>
<td valign="top" align="center">60.1&#x2009;&#x00B1;&#x2009;11.8</td>
<td valign="top" align="center">65.7&#x2009;&#x00B1;&#x2009;13.5</td>
<td valign="top" align="center">59.9&#x2009;&#x00B1;&#x2009;14.1</td>
</tr>
<tr>
<td valign="top" align="left">Male, <italic>N</italic> (&#x0025;)</td>
<td valign="top" align="center">120 (60)</td>
<td valign="top" align="center">25 (50)</td>
<td valign="top" align="center">36 (60)</td>
<td valign="top" align="center">28 (70)</td>
<td valign="top" align="center">31 (62)</td>
</tr>
<tr>
<td valign="top" align="left">Hypertension, <italic>N</italic> (&#x0025;)</td>
<td valign="top" align="center">95 (47.5)</td>
<td valign="top" align="center">20 (40)</td>
<td valign="top" align="center">31 (51.7)</td>
<td valign="top" align="center">18 (45)</td>
<td valign="top" align="center">26 (52)</td>
</tr>
<tr>
<td valign="top" align="left">Diabetes, <italic>N</italic> (&#x0025;)</td>
<td valign="top" align="center">83 (41.5)</td>
<td valign="top" align="center">18 (36)</td>
<td valign="top" align="center">26 (43.3)</td>
<td valign="top" align="center">15 (37.5)</td>
<td valign="top" align="center">24 (48)</td>
</tr>
<tr>
<td valign="top" align="left">Smoking History, <italic>N</italic> (&#x0025;)</td>
<td valign="top" align="center">65 (32.5)</td>
<td valign="top" align="center">12 (24)</td>
<td valign="top" align="center">20 (33.3)</td>
<td valign="top" align="center">14 (35)</td>
<td valign="top" align="center">19 (38)</td>
</tr>
</tbody>
</table>
</table-wrap>
<table-wrap id="T2" position="float"><label>Table&#x00A0;2</label>
<caption><p>Functional classification and clinical significance of cardiovascular biomarkers employed and highlighted in this study.</p></caption>
<table>
<thead>
<tr>
<th valign="top" align="left">Biomarker</th>
<th valign="top" align="center">Function</th>
<th valign="top" align="center">Clinical role in CVD</th>
<th valign="top" align="center">Comparison with CtnI, BNP, and CRP</th>
<th valign="top" align="center">reference</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Cardiac troponin I (cTnI)</td>
<td valign="top" align="left">Regulates cardiac muscle contraction</td>
<td valign="top" align="left">Gold standard for myocardial infarction diagnosis</td>
<td valign="top" align="left">Highly specific and sensitive for myocardial damage</td>
<td valign="top" align="center">(<xref ref-type="bibr" rid="B39">39</xref>)</td>
</tr>
<tr>
<td valign="top" align="left">Brain natriuretic peptide (BNP)</td>
<td valign="top" align="left">Released in response to ventricular stretch</td>
<td valign="top" align="left">Diagnoses and monitors heart failure</td>
<td valign="top" align="left">Complementary to cTnI, reflects hemodynamic stress</td>
<td valign="top" align="center">(<xref ref-type="bibr" rid="B42">42</xref>)</td>
</tr>
<tr>
<td valign="top" align="left">C-reactive protein (CRP)</td>
<td valign="top" align="left">Inflammatory marker</td>
<td valign="top" align="left">Predicts cardiovascular events and inflammation</td>
<td valign="top" align="left">Less specific; used in combination with others</td>
<td valign="top" align="center">(<xref ref-type="bibr" rid="B44">44</xref>)</td>
</tr>
<tr>
<td valign="top" align="left">CK-MB (creatine kinase-MB)</td>
<td valign="top" align="left">Enzyme in cardiac muscle</td>
<td valign="top" align="left">Previously used for myocardial infarction diagnosis</td>
<td valign="top" align="left">Replaced by cTnI due to lower specificity</td>
<td valign="top" align="center">(<xref ref-type="bibr" rid="B40">40</xref>)</td>
</tr>
<tr>
<td valign="top" align="left">NT-proBNP</td>
<td valign="top" align="left">Inactive fragment of BNP precursor</td>
<td valign="top" align="left">Alternative to BNP for heart failure</td>
<td valign="top" align="left">Similar utility but longer half-life than BNP</td>
<td valign="top" align="center">(<xref ref-type="bibr" rid="B43">43</xref>)</td>
</tr>
<tr>
<td valign="top" align="left">Myoglobin</td>
<td valign="top" align="left">Oxygen-binding protein in the muscle</td>
<td valign="top" align="left">Early MI marker, but not specific to heart</td>
<td valign="top" align="left">Rapidly rises but lacks cardiac specificity</td>
<td valign="top" align="center">(<xref ref-type="bibr" rid="B41">41</xref>)</td>
</tr>
<tr>
<td valign="top" align="left">hs-CRP (high-sensitivity CRP)</td>
<td valign="top" align="left">Detects low-level inflammation</td>
<td valign="top" align="left">Useful in risk stratification for CVD</td>
<td valign="top" align="left">Improved sensitivity over traditional CRP</td>
<td valign="top" align="center">(<xref ref-type="bibr" rid="B46">46</xref>)</td>
</tr>
<tr>
<td valign="top" align="left">Galectin-3</td>
<td valign="top" align="left">Fibrosis and inflammation marker</td>
<td valign="top" align="left">Emerging marker for heart failure prognosis</td>
<td valign="top" align="left">Not yet standard clinical practice</td>
<td valign="top" align="center">(<xref ref-type="bibr" rid="B45">45</xref>)</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>As shown in the <xref ref-type="table" rid="T1">Table 1</xref> the patients are fairly evenly distributed across different health categories, with the average age of 58.6 (&#x00B1;13.4) years. The male population comprised 60&#x0025; of the study, because CVDs have for long been known to affect the male gender more. Among suspected and confirmed CVD patients, hypertension and diabetes were the most common and are related to traditional risk factors of cardiovascular incidents. Interestingly, smoking history was documented in 32.5&#x0025; of participants; a higher proportion was identified among the confirmed MI and heart failure groups, hence the influence of the lifestyle factor on cardiovascular health.</p>
</sec>
<sec id="s4b"><label>3.2</label><title>Biomarker levels across health Status categories</title>
<p>Both <xref ref-type="sec" rid="s13">Supplementary Table S2</xref> and the corresponding <xref ref-type="fig" rid="F2">Figure&#x00A0;2</xref> provide information regarding the mean concentrations (&#x00B1; standard deviation) of three cardiac biomarkers, cTnI), BNP, and CRP. These biomarkers were detected in four patient categories that were classified according to their cardiovascular health status. These categories were asymptomatic, suspected of having CVD, confirmed to have MI, and diagnosed with heart failure. As demonstrated, the concentration of cTnI increases dramatically from 0.03&#x2005;ng/mL in individuals who are asymptomatic to 5.6&#x2005;ng/mL in those with verified myocardial infarction, which is indicative of its excellent specificity for myocardial damage. BNP, which is a measure of ventricular strain, gradually increases from 30&#x2005;pg/mL in persons who are asymptomatic to 800&#x2005;pg/mL in patients who are suffering from cardiac failure. This is consistent with the role that BNP plays in the pathophysiology regarding heart failure. In addition, CRP, which is a measure of inflammation, increases gradually from 1.5 to 15.8&#x2005;mg/L. Higher levels of CRP are observed in both myocardial infarction and heart failure, which indicates that systemic inflammation is in progress. These conclusions are visually reinforced by the grouped bar chart, which provides a visual representation of both the central tendency and the variation by utilizing color-coded bars and error margins. The table and the graph, when used together, provide an illustration of the diagnostic and prognostic significance of these biomarkers. They demonstrate the ability of the biomarkers to differentiate between different degrees of illness severity and to provide assistance for making clinical choices.</p>
<fig id="F2" position="float"><label>Figure&#x00A0;2</label>
<caption><p>Comparative analysis of mean concentrations (&#x00B1;SD) of cardiac biomarkers cTnI, BNP, and CRP across clinical health categories, demonstrating a progressive increase with deteriorating cardiovascular condition and underscoring their diagnostic significance in myocardial infraction and cardiac failure.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fcvm-12-1600695-g002.tif"><alt-text content-type="machine-generated">Bar chart titled "Mean &#x00B1; SD of Biomarkers by Health Status (Log Scale)" showing log-transformed concentrations of three biomarkers&#x2014;cTnI (ng/mL), BNP (pg/mL), and CRP (mg/L)&#x2014;across four health status groups: Asymptomatic (N=50), Suspected CVD (N=60), Confirmed MI (N=40), and Heart Failure (N=50). BNP levels increase markedly with disease severity, peaking in heart failure. CRP and cTnI also rise progressively, especially in confirmed MI. Error bars indicate standard deviation.</alt-text>
</graphic>
</fig>
<fig id="F3" position="float"><label>Figure&#x00A0;3</label>
<caption><p>Comparison of diagnostic performance metrics-sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV)-of three cardiac biomarkers: cardiac troponin I (cTnI&#x2009;&#x2265;&#x2009;0.10&#x2005;ng/mL), B-type natriuretic peptide (BNP&#x2009;&#x2265;&#x2009;100&#x2005;pg/mL), and C-reactive protein (CRP&#x2009;&#x2265;&#x2009;5&#x2005;mg/L). Threshold values are indicated in parentheses below on X-axis. Among the three, cTnI exhibits the highest sensitivity (95.2&#x0025;) and NPV (96.5&#x0025;), supporting its clinical utility in ruling out cardiac events. BNP and CRP also demonstrate strong diagnostic potential, with all biomarkers maintaining over 85&#x0025; accuracy in the displayed parameters. The high NPV of cTnI and CRP suggests their potential in early triage of suspected cardiovascular cases.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fcvm-12-1600695-g003.tif"><alt-text content-type="machine-generated">Bar chart titled "Mean &#x00B1; SD of Biomarkers by Health Status (Log Scale)" showing log-transformed concentrations of three biomarkers&#x2014;cTnI (ng/mL), BNP (pg/mL), and CRP (mg/L)&#x2014;across four health status groups: Asymptomatic (N=50), Suspected CVD (N=60), Confirmed MI (N=40), and Heart Failure (N=50). BNP levels increase markedly with disease severity, peaking in heart failure. CRP and cTnI also rise progressively, especially in confirmed MI. Error bars indicate standard deviation.</alt-text>
</graphic>
</fig>
</sec>
<sec id="s4c"><label>3.3</label><title>Diagnostic performance of the rapid test</title>
<p>Figure 3 provides a comparative examination of four important diagnostic accuracy metrics: sensitivity, specificity, PPV, and NPV for the three cardiac biomarkers: cTnI, BNP, and CRP. Each of these biomarkers was examined at their corresponding clinical thresholds. A measurement of cardiac troponin I (cTnI) at a concentration of &#x2265;0.10&#x2005;ng/mL displays the highest sensitivity (95.2&#x0025;) and NPV (96.5&#x0025;). This highlights its remarkable capacity to accurately identify patients who have experienced cardiovascular events and to successfully rule out disease in circumstances when the test results are negative. In addition, BNP, which has a threshold of &#x2265;100&#x2005;pg/mL, demonstrates remarkable performance, particularly in terms of sensitivity (91.8&#x0025;) and NPV (91.2&#x0025;), which further strengthens its significance in the diagnostic process of heart failure. With a sensitivity of approximately 89.0&#x0025; and a specificity of approximately 87.2&#x0025;, CRP, when evaluated at a concentration of at least 5&#x2005;mg/L, possesses values that are slightly lower but still clinically relevant. With cTnI demonstrating the most consistent and superior performance across all parameters, the high NPVs of all biomarkers indicate that they have the potential to be useful for initial triage and avoidance of cardiovascular events <xref ref-type="sec" rid="s13">Supplementary Table S3</xref>.</p>
<sec id="s4c1"><label>3.3.1</label><title>ROC curves for biomarker sensitivity and specificity</title>
<p>The results of the receiver operating characteristic area beneath the curve (ROC-AUC) for the same three biomarkers are shown in <xref ref-type="fig" rid="F4">Figure&#x00A0;4</xref>, along with the corresponding confidence intervals for each of the three biomarkers. It is a measurement of the total diagnostic accuracy of the test across all of the potential levels of the threshold, which is referred to as the ROC-AUC. With a confidence interval that is quite narrow, ranging from 0.91&#x2013;0.97, cTnI has the highest ROC-AUC value, which is 0.94. This indicates that it has excellent discriminative power and reliability. Both BNP and CRP are deemed to be strong in clinical diagnostic terms, with ROC-AUCs of 0.90 (95&#x0025; CI: 0.87&#x2013;0.94) and 0.89 (95&#x0025; CI: 0.85&#x2013;0.92), respectively <xref ref-type="sec" rid="s13">Supplementary Table S3</xref>. These values are considered to be in proximity to one another. For each and every biomarker, the narrow confidence intervals are a reflection of the consistency and precision of the measurement. These findings not only provide support for the clinical relevance of BNP and CRP as complementary tools in the early detection and assessment of cardiovascular conditions, but they also provide reaffirmation of the superior diagnostic accuracy of cTnI.</p>
<fig id="F4" position="float"><label>Figure&#x00A0;4</label>
<caption><p>Receiver operating characteristic area under the curve (ROC-AUC) values for cTnI, BNP, and CRP, plotted with their respective 95&#x0025; confidence intervals (CIs). Biomarker thresholds are shown in front each marker label. cTnI achieves the highest ROC-AUC (0.94, 95&#x0025; CI: 0.91&#x2013;0.97), indicating excellent discriminative power in detecting cardiovascular events. BNP and CRP follow with AUCs of 0.90 and 0.89, respectively, also within clinically meaningful ranges. The narrow confidence intervals reflect reliable diagnostic precision, especially for cTnI. This analysis underscores the superior classification capability of cTnI and affirms the diagnostic value of BNP and CRP in clinical settings.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fcvm-12-1600695-g004.tif"><alt-text content-type="machine-generated">Dot plot titled "ROC-AUC with 95% Confidence Intervals" comparing diagnostic performance of three cardiac biomarkers: cTnI (&#x2265;0.10 ng/mL), BNP (&#x2265;100 pg/mL), and CRP (&#x2265;5 mg/L). Each biomarker is represented by a dot indicating the mean ROC-AUC value with a horizontal line denoting the 95% confidence interval. cTnI shows the highest ROC-AUC near 0.95, followed by BNP around 0.90, and CRP near 0.87, indicating strong overall diagnostic accuracy for all three.</alt-text>
</graphic>
</fig>
<fig id="F5" position="float"><label>Figure&#x00A0;5</label>
<caption><p>Comparative graph of biomarker levels (mean&#x2009;&#x00B1;&#x2009;SD) obtained using quick testing and normal laboratory assay methods for cTnI, BNP, and CRP. Each point denotes the mean concentration of the biomarker assessed in clinical specimens, with the error bars representing the standard deviation. Rapid test results (circles, solid lines) and conventional assay results (squares, dashed lines) exhibit substantial concordance across all biomarkers. The Pearson correlation coefficient (<italic>r</italic>&#x2009;&#x003D;&#x2009;0.9998) and <italic>p</italic>-value (<italic>p</italic>&#x2009;&#x003D;&#x2009;0.0189) are presented individually on the graph, indicating a statistically significant positive connection between the two approaches. The results validate the diagnostic equivalence of quick testing and traditional assays in biomarker quantification.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fcvm-12-1600695-g005.tif"><alt-text content-type="machine-generated">Line chart titled "Biomarker Concentration: Rapid Test vs. Standard Assay (Mean &#x00B1; SD)" comparing mean concentrations of cTnI, BNP, and CRP between rapid test (blue line with circles) and standard assay (orange dashed line with squares). For all three biomarkers, measurements from both methods closely align, with BNP showing the highest values around 460 pg/mL (rapid) and 450 pg/mL (standard). Pearson correlation is reported as r = 1.0000, and a p-value of 0.0001 is indicated near CRP, suggesting statistically significant agreement. Error bars represent standard deviations.</alt-text>
</graphic>
</fig>
<fig id="F6" position="float"><label>Figure&#x00A0;6</label>
<caption><p>Comparison of the coefficients of variation (CVs, &#x0025;) for repeatability and reproducibility across cTnI, BNP, and CRP as assessed using the rapid testing technique. The bars illustrate the average coefficients of variation for repeatability (blue) and reproducibility (orange). All values below 7&#x0025;&#x2013;10&#x0025;, indicate exceptional analytical precision. Limit of detection (LOD) values for each biomarker are indicated above the bars, demonstrating elevated assay sensitivity appropriate for clinical diagnosis.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fcvm-12-1600695-g006.tif"><alt-text content-type="machine-generated">Bar chart titled "Repeatability and Reproducibility CVs by Biomarker" comparing the coefficient of variation (CV) for repeatability and reproducibility in three biomarkers: cTnI, BNP, and CRP. For cTnI, repeatability CV is 4.5% and reproducibility CV is 5.2% with LOD of 0.03 ng/mL. For BNP, repeatability is 5.3% and reproducibility is 6.1% with LOD of 10 pg/mL. For CRP, repeatability is 5.8% and reproducibility is 6.7% with LOD of 1 mg/L. Repeatability is shown in green, reproducibility in orange. Bars are labeled with percentages.</alt-text>
</graphic>
</fig>
</sec>
</sec>
<sec id="s4d"><label>3.4</label><title>Correlation analysis between rapid test and conventional assays</title>
<p>The <xref ref-type="fig" rid="F5">Figure 5</xref> below illustrates a comparative comparison of mean concentrations (&#x00B1; standard deviation) of the three main cardiovascular biomarkers&#x2014;cTnI, BNP, and CRP&#x2014;assessed using both fast test kits and traditional laboratory tests. The error bar plot illustrates the consistency and dependability of the quick testing approach in estimating results derived from conventional assays.</p>
<p>Notwithstanding their biological and unit disparities (cTnI in ng/mL, BNP in pg/mL, and CRP in mg/L), the data derived from both approaches exhibit a strong correlation among all biomarkers, with only negligible variations within standard deviations. The Pearson correlation coefficient (<italic>r</italic>&#x2009;&#x003D;&#x2009;0.999) indicates a nearly flawless linear relationship, demonstrating exceptional concordance between the two assessment modalities. The associated <italic>p</italic>-value (<italic>p</italic>&#x2009;&#x003C;&#x2009;0.001) substantiates the statistical importance of this link. This alignment reinforces the analytical validity of the quick test method, indicating that it may function as a time-efficient and cost-effective substitute for standard assays, especially at point-of-care or emergency contexts when diagnostic speed is essential. Further details are provided in <xref ref-type="sec" rid="s13">Supplementary Table S4</xref>.</p>
</sec>
<sec id="s4e"><label>3.5</label><title>Limit of detection and reproducibility</title>
<p>The <xref ref-type="fig" rid="F6">Figure 6</xref> presents a comparison of the coefficient of variation (CV&#x0025;) for repeatability and reproducibility among the three biomarkers, as determined by the performance features of a rapid diagnostic test. The repeatability coefficient of variation (CV) indicates intra-assay variability under identical conditions, whereas the reproducibility CV denotes interassay variability across different days, operators, or tools. A lower coefficient of variation signifies greater precision.</p>
<p>Repeatability coefficients of variation (CVs) range from 4.5&#x0025; for cTnI to 5.8&#x0025; for CRP, whereas reproducibility CVs range from 5.2&#x0025; for cTnI to 6.7&#x0025; for CRP. The data indicate a constant low variability, as all coefficients of variation are significantly below 10&#x0025;, an acceptable threshold for clinical biomarker assays. The limit of detection (LOD) for each biomarker is specified as follows: 0.03&#x2005;ng/mL for cTnI, 10&#x2005;pg/mL for BNP, and 1&#x2005;mg/L for CRP. These values demonstrate high assay sensitivity and significant clinical utility, particularly in early detection contexts; details are provided in <xref ref-type="sec" rid="s13">Supplementary Table S5</xref>.</p>
</sec>
<sec id="s4f"><label>3.6</label><title>Cost and turnaround time analysis</title>
<p>The cost-effectiveness of the rapid test compared with conventional methods is summarized in <xref ref-type="sec" rid="s13">Supplementary Table S6</xref>. This table highlights the mean turnaround time and associated costs per test. The rapid test offers substantial advantages in both cost and turnaround time. While the average laboratory assay requires 60&#x2013;90&#x2005;min per test, the rapid test achieves results in 15&#x2005;min at a fraction of the cost, enhancing accessibility and feasibility for point-of-care settings. These cost and time reductions position the rapid test as an efficient alternative, particularly useful in resource-limited environments. <xref ref-type="fig" rid="F7">Figure&#x00A0;7</xref> provides a comparative comparison of four diagnostic procedures frequently employed in cardiovascular evaluation: rapid test, ELISA for cTnI, BNP assay, and high-sensitivity CRP. Two essential criteria are analyzed: turnaround time (minutes) and cost per test (USD).</p>
<fig id="F7" position="float"><label>Figure&#x00A0;7</label>
<caption><p>A comparative bar chart depicting turnaround time (in minutes) and cost per test (in USD) for four cardiovascular diagnostic procedures. Rapid tests offer the quickest processing duration (15&#x2005;min) and minimal expense (&#x0024;5/test), but ELISA for cTnI is the most time-consuming and costly (90&#x2005;min, &#x0024;20/test). BNP and CRP tests demonstrate moderate efficacy in both metrics. The graphic highlights the trade-offs between diagnostic efficiency and operational expense, emphasizing the practical value of rapid testing in urgent clinical environments.</p></caption>
<graphic mimetype="image" mime-subtype="tiff" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fcvm-12-1600695-g007.tif"><alt-text content-type="machine-generated">Dual-axis chart titled "Cost and Turnaround Time Comparison" comparing four diagnostic methods: Rapid Test, ELISA for cTnI, BNP Assay, and High-Sensitivity CRP. Blue bars represent cost per test in USD, showing the rapid test as the lowest at approximately 5 USD, while ELISA is highest at 20 USD. An overlaid orange line shows turnaround time in minutes, ranging from 15 minutes for the rapid test to 90 minutes for ELISA. BNP and CRP assays have intermediate costs and times.</alt-text>
</graphic>
</fig>
<p>The rapid test exhibits the quickest efficiency, with a turnaround time of 15&#x2005;min and a minimal cost of &#x0024;5 per test, underscoring its appropriateness for point-of-care and emergency environments. Conversely, the ELISA for cTnI necessitates a somewhat extended processing duration of 90&#x2005;min and entails the highest expense (&#x0024;20/test), rendering it more appropriate for centralized laboratory operations. The BNP assay and high-sensitivity CRP are positioned intermediately, with turnaround times of 75 and 60&#x2005;min and costs of &#x0024;18 and &#x0024;15, respectively.</p>
<p>The bar graph distinctly illustrates the trade-offs between velocity and expense in medical decision-making. Standard tests exhibit good sensitivity and specificity; however, the rapid test presents a quicker, cost-effective alternative, potentially enhancing early triage and resource distribution in acute care settings.</p>
</sec>
</sec>
<sec id="s5" sec-type="discussion"><label>4</label><title>Discussion</title>
<p>The rapid test developed for the identification of cTnI, BNP, and CRP, key cardiac biomarkers of myocardial injury, showed potential as a rapid and sensitive diagnostic tool for use in emergency, primary care, and other POC settings. The discussion compares this study results with the literature, emphasizes the importance of achieving high diagnostic accuracy of the rapid test, and discusses the limitations of the study along with directions for future research.</p>
<sec id="s5a"><label>4.1</label><title>Diagnostic performance and clinical utility</title>
<p>The high sensitivity and specificity of the rapid test, especially for cTnI, underscore its clinical value in accurately diagnosing myocardial infarction (MI) early. Biomarker cTnI demonstrated an overall sensitivity of 95.2&#x0025; at a cutoff value of 0.10 ng/mL, along with a specificity of 92.4&#x0025; and an AUC of 0.94. These results are in line with prior findings, where high-sensitivity troponin assays have reported high diagnostic concordance for MI detection (<xref ref-type="bibr" rid="B4">4</xref>, <xref ref-type="bibr" rid="B5">5</xref>, <xref ref-type="bibr" rid="B7">7</xref>). Thygesen. (<xref ref-type="bibr" rid="B6">6</xref>) and Neumann et al. (<xref ref-type="bibr" rid="B4">4</xref>) reported cTnI sensitivities of 94.6&#x0025; and specificities of 91.8&#x0025; using high-sensitivity assays. The close agreement between these results and those of the current study justifies that the rapid test is effective without compounding the need for infrastructure enhancement in the laboratory.</p>
<p>BNP, a biomarker of cardiac stress, demonstrated 91.8&#x0025; sensitivity and 88.6&#x0025; specificity for the diagnosis of heart failure, with an AUC of 0.90. High levels of BNP are indicative of heart failure and left ventricular dysfunction (<xref ref-type="bibr" rid="B37">37</xref>), and previous research has supported the usefulness of BNP assays for early detection and risk assessment in patients with suspected heart failure (<xref ref-type="bibr" rid="B11">11</xref>, <xref ref-type="bibr" rid="B12">12</xref>). For instance, Cullen et al. (<xref ref-type="bibr" rid="B8">8</xref>) reported that BNP &#x003E; 100 pg/mL achieved a high sensitivity of 90&#x0025; and a specificity of 86&#x0025; in diagnosing heart failure, findings that are greatly consistent with those of our study. The ability of the rapid test to provide real-time assessment of elevated BNP levels represents a major advantage, particularly in facilities where access to laboratory-based BNP assays is a challenge, enabling earlier intervention.</p>
<p>CRP, a common inflammatory marker, demonstrated a sensitivity of 89.0&#x0025; and a specificity of 87.2&#x0025; at a cutoff value of 5 mg/L, with an AUC of 0.89. This level of diagnostic accuracy is significant, as increased CRP levels are associated with poor prognosis and the presence of systemic inflammation, both of which indicate a potential risk of cardiovascular events. Wang et al., Cook et al., and Ridker et al. (<xref ref-type="bibr" rid="B14">14</xref>, <xref ref-type="bibr" rid="B15">15</xref>, <xref ref-type="bibr" rid="B38">38</xref>) employed human sensitivity CRP assays and reported raised CRP levels with 88&#x0025; sensitivity, closely aligning with the performance of the CRP test reported here. Together, these results underscore the importance of the rapid test in the POC diagnostics, as it allows simultaneous detection of multiple biomarkers relevant to different CV disorders and supports faster decision-making by clinicians.</p>
</sec>
<sec id="s5b"><label>4.2</label><title>Comparison with traditional laboratory assays</title>
<p>The results we obtained for all biomarkers showed a high level of correlation between the SARS-CoV-2 rapid test and biochemical laboratory assays, demonstrating consistency, with Pearson correlation coefficients exceeding 0.85. For cTnI, the correlation coefficient was 0.92 (<italic>p</italic> &#x003C; 0.001); similar results were found in other studies assessing high-sensitivity troponin assays (<xref ref-type="bibr" rid="B3">3</xref>, <xref ref-type="bibr" rid="B5">5</xref>, <xref ref-type="bibr" rid="B17">17</xref>). Likewise, BNP and CRP showed strong correlation coefficients of 0.89 and 0.87, respectively, indicating that the rapid test provides diagnostic terminologies equivalent to those of laboratory-based assays.</p>
<p>The comparison of time-to-result and testing cost further underscores the value of the rapid test. The currently available assays for cTnI and BNP require 90 min to complete at a relatively high cost, whereas the rapid test provides results within 15 min at a substantially lower cost. These results align with the views of Crapnell et al. (<xref ref-type="bibr" rid="B10">10</xref>) and Maisel et al. (<xref ref-type="bibr" rid="B11">11</xref>), who emphasize the need for fast, low-cost diagnostic approaches for better patient classification and more efficient use of medical resources. Rapid results, however, are crucial in emergency and primary care settings, where timely diagnosis results and prompt treatment decisions are imperative due to the quick progression of the disease.</p>
<p><xref ref-type="table" rid="T2">Table 2</xref> outlines a comparative analysis of various cardiovascular biomarkers. The biomarkers selected for this study&#x2014;cardiac troponin I (cTnI), brain natriuretic peptide (BNP), and C-reactive protein (CRP)&#x2014;were chosen due to their robust clinical validation and extensive use in cardiovascular diagnostics. cTnI is considered the gold-standard biomarker for diagnosing myocardial infarction due to its superior specificity and sensitivity compared to older markers such as CK-MB and myoglobin, both of which have been largely supplanted in contemporary practice (<xref ref-type="bibr" rid="B40">40</xref>, <xref ref-type="bibr" rid="B43">43</xref>, <xref ref-type="bibr" rid="B45">45</xref>). BNP functions as a key biomarker for diagnosing and monitoring heart failure, providing prompt information regarding ventricular stress. While its diagnostic efficacy is comparable to that of NT-pro-BNP, BNP is more frequently utilized in rapid testing platforms (<xref ref-type="bibr" rid="B41">41</xref>, <xref ref-type="bibr" rid="B44">44</xref>). C-reactive protein (CRP), despite its lower specificity, is a clinically relevant and affordable inflammatory indicator of cardiovascular risk. Its use is warranted due to its availability and compatibility with point-of-care platforms (<xref ref-type="bibr" rid="B42">42</xref>). While Hs-CRP (<xref ref-type="bibr" rid="B7">7</xref>) and Galectin-3 (<xref ref-type="bibr" rid="B47">47</xref>) offer enhanced prognostic value and improved risk stratification, their integration into standard clinical workflows is still limited or under development. This study emphasized biomarkers that optimize diagnostic accuracy, cost-effectiveness, and feasibility for rapid testing applications. A comparative table would further elucidate the strategic rationale behind biomarker selection and demonstrate how these three markers provide complementary insights into myocardial injury, hemodynamic stress, and systemic inflammation. </p>
</sec>
<sec id="s5c"><label>4.3</label><title>Limitations and considerations</title>
<p>The study instituted numerous essential quality assurance procedures to mitigate potential systematic biases and guarantee robust test performance in point-of-care (POC) settings. Acknowledging that POC tests are susceptible to variability arising from reagent instability, environmental conditions, and user handling, uniform protocols were implemented across all LFIA procedures. High-quality antibodies and antigen conjugates, which markedly affect assay specificity and sensitivity, were stored under controlled humidity and temperature conditions to sustain bioactivity and avert degradation&#x2014;an issue commonly noted in field-based diagnostic platforms (<xref ref-type="bibr" rid="B48">48</xref>, <xref ref-type="bibr" rid="B49">49</xref>). To mitigate inter-batch variability, each assay run incorporated internal positive and negative controls with predetermined biomarker levels, facilitating real-time validation of test accuracy and consistency of signal generation (<xref ref-type="bibr" rid="B50">50</xref>).</p>
<p>Furthermore, repeated testing was performed under diverse ambient settings to replicate real-world environments, acknowledging that factors such as humidity, temperature fluctuations, and variations in sample viscosity can profoundly affect LFIA membrane flow dynamics and analyte&#x2013;antibody binding kinetics (<xref ref-type="bibr" rid="B51">51</xref>, <xref ref-type="bibr" rid="B52">52</xref>). These environmental stress tests confirmed that the assay sustained adequate analytical efficacy across various operational conditions, which is an essential requirement for implementation in resource-constrained or emergency settings. The proactive design components conform to the World Health Organization&#x0027;s ASSURED standards (Affordable, Sensitive, Specific, User-friendly, Rapid, Equipment-free, and Deliverable), highlighting the importance of environmental resilience and operational repeatability for diagnostic tools intended for decentralized environments (<xref ref-type="bibr" rid="B53">53</xref>). By implementing these mitigation measures, the study sought to improve test reliability, reduce errors arising from human and environmental factors, and facilitate the practical integration of the assay into clinical settings.</p>
<p>The study acknowledges numerous shortcomings that may limit its generalizability. Although 200 volunteers were recruited, this sample size may not adequately represent broader communities. The study also lacked a multivariable or longitudinal design, which prevented it from evaluating long-term health outcomes or comparing the cost-effectiveness of the test against routine diagnostic pathways. No longitudinal follow-up was conducted to assess the impact of the test on patient prognosis or treatment. To address these gaps, larger multicenter studies, incorporating cross-sectional and longitudinal designs, are needed to expand the present findings.</p>
<p>Inflammatory conditions such as sepsis, autoimmune diseases, and certain malignancies can provide false-positive CRP test results that are unrelated to cardiovascular diseases (<xref ref-type="bibr" rid="B17">17</xref>, <xref ref-type="bibr" rid="B42">42</xref>). Despite this, the assay used in this study demostrated 87.2&#x0025; specificity, indicating reliability. However, multiplex testing technologies that can distinguish cardiac-specific inflammation from general systemic responses could further improve clinical diagnostic accuracy.</p>
</sec>
<sec id="s5d"><label>4.4</label><title>To overcome the risks of false-positive and false-negative results</title>
<p>Although LFIA-based approaches possess fundamentally poorer sensitivity and specificity than laboratory-based platforms such as ELISA or chemiluminescent assays (<xref ref-type="bibr" rid="B54">54</xref>), the current study showed comparatively strong diagnostic performance across all evaluated biomarkers. CRP, BNP, and cTnI exhibited specificities ranging from 87.2&#x0025; to 92.4&#x0025; and sensitivities ranging from 89.0&#x0025; to 95.2&#x0025;, with AUC values of at least 0.89, signifying clinically acceptable precision.</p>
<p>Nonetheless, the potential for false positives and false negatives persists, especially with CRP, which may be elevated in non-cardiac inflammatory conditions like sepsis, autoimmune diseases, and certain malignancies (<xref ref-type="bibr" rid="B55">55</xref>). The lack of specificity may result in false-positive interpretations when CRP is utilized independently, particularly in individuals with elevated BMI or chronic systemic inflammation (<xref ref-type="bibr" rid="B56">56</xref>). Conversely, false negatives may occur due to diminished analyte concentrations in the earliest stages of myocardial infarction or variability in the assay caused by temperature, humidity, or human manipulation&#x2014;issues that are prevalent in field-deployed LFIA environments (<xref ref-type="bibr" rid="B50">50</xref>, <xref ref-type="bibr" rid="B57">57</xref>).</p>
<p>To address these concerns, our investigation utilized internal quality controls, repeated testing across diverse ambient conditions, and batch-to-batch validation using established biomarker standards, in accordance with WHO recommendations and best practices for point-of-care diagnostic design (<xref ref-type="bibr" rid="B58">58</xref>). However, multiplex testing methodologies and their integration with clinical symptomatology may further diminish diagnostic ambiguity in future LFIA-based applications.</p>
</sec>
<sec id="s5e"><label>4.5</label><title>Implications for clinical practice and future directions</title>
<p>Based on the results of this study, it can be concluded that the rapid test for cardiac biomarkers could have significant practical value, especially in healthcare centers with limited laboratory facilities. Due to its high sensitivity and specificity for cTnI, BNP, and CRP, the test can effectively diagnose patients at risk of potential cardiovascular events and promote early treatment. Point-of-care diagnostic methods that are very simple and easy to use have the potential to improve health outcomes by reducing the duration required for individuals in at-risk categories to receive their results and initiate appropriate treatment (<xref ref-type="bibr" rid="B19">19</xref>, <xref ref-type="bibr" rid="B20">20</xref>).</p>
<p>For future studies, there is a need to improve the sensitivity and specificity of rapid diagnostic tests and consider including other biomarkers to improve diagnosis. Future improvements in biosensing technologies, including nanomaterials and electrochemical detection methods, could enhance the rapid test by detecting biomarker levels associated with latent or prodromal forms of the disease (<xref ref-type="bibr" rid="B18">18</xref>, <xref ref-type="bibr" rid="B20">20</xref>, <xref ref-type="bibr" rid="B23">23</xref>). Further, combining biomarker analysis with artificial intelligence-based algorithms could make the interpretation of results more accurate and provide additional support in decision-making (<xref ref-type="bibr" rid="B8">8</xref>, <xref ref-type="bibr" rid="B20">20</xref>).</p>
</sec>
</sec>
<sec id="s6" sec-type="conclusions"><label>5</label><title>Conclusion</title>
<p>In light of the above, the proposed rapid test for the identification of cardiac biomarkers provides excellent diagnostic precision and affordability while showcasing its potential for early detection of cardiovascular diseases, especially in POC environments. This supports prior literature on integrating biomarkers like cTnI, BNP, and CRP in a clinical context where early diagnosis of CVD is crucial. There are some limitations in using the rapid test; however, this test is one of the promising POC tests that can benefit the patient through early diagnosis and intervention. More studies should be conducted to refine the test and establish its viability for use in a range of capacitors to determine its potential for diagnostics.</p>
</sec>
</body>
<back>
<sec id="s7" sec-type="data-availability"><title>Data availability statement</title>
<p>The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.</p>
</sec>
<sec id="s8" sec-type="ethics-statement"><title>Ethics statement</title>
<p>The ethical review board of COMSATS University, Islamabad, Pakistan, has approved this study (Ethical Review Board Approval &#x0023;CUI/Notif/21/3395-1). The studies were conducted in accordance with the local legislation and institutional requirements. Written informed consent for participation was not required from the participants or the participants&#x0027; legal guardians/next of kin in accordance with the local legislation and institutional requirements.</p>
</sec>
<sec id="s9" sec-type="author-contributions"><title>Author contributions</title>
<p>RU: Conceptualization, Methodology, Validation, Investigation, Resources, Data curation, Writing &#x2013; original draft, Writing &#x2013; review &#x0026; editing. MK: Conceptualization, Methodology, Validation, Investigation, Data curation, Writing &#x2013; review &#x0026; editing. YH: Conceptualization, Methodology, Validation, Formal analysis, Investigation, Resources, Data curation, Writing &#x2013; review &#x0026; editing, Funding acquisition. GW: Conceptualization, Methodology, Formal analysis, Resources, Data curation, Writing &#x2013; review &#x0026; editing, Funding acquisition.</p>
</sec>
<sec id="s11" sec-type="COI-statement"><title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec id="s12" sec-type="ai-statement"><title>Generative AI statement</title>
<p>The author(s) declare that no Generative AI was used in the creation of this manuscript.</p>
<p>Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence, and reasonable efforts have been made to ensure accuracy, including review by the authors, wherever possible. If you identify any issues, please contact us.</p>
</sec>
<sec id="s14" sec-type="disclaimer"><title>Publisher&#x0027;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<sec id="s13" sec-type="supplementary-material"><title>Supplementary material</title>
<p>The Supplementary Material for this article can be found online at: <ext-link ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/fcvm.2025.1600695/full#supplementary-material">https://www.frontiersin.org/articles/10.3389/fcvm.2025.1600695/full&#x0023;supplementary-material</ext-link></p>
<supplementary-material xlink:href="Table1.doc" id="SM1" mimetype="application/msword"/>
</sec>
<ref-list><title>References</title>
<ref id="B1"><label>1.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Do</surname> <given-names>NT</given-names></name> <name><surname>Bellingham</surname> <given-names>K</given-names></name> <name><surname>Newton</surname> <given-names>PN</given-names></name> <name><surname>Caillet</surname> <given-names>C</given-names></name></person-group>. <article-title>The quality of medical products for cardiovascular diseases: a gap in global cardiac care</article-title>. <source>BMJ Glob Health</source>. (<year>2021</year>) <volume>6</volume>(<issue>9</issue>):<fpage>e006523</fpage>. <pub-id pub-id-type="doi">10.1136/bmjgh-2021-006523</pub-id><pub-id pub-id-type="pmid">34521627</pub-id></mixed-citation></ref>
<ref id="B2"><label>2.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Osawa</surname> <given-names>K</given-names></name></person-group>. <article-title>The role of cardiac injury biomarkers as risk predictors for peripheral artery disease: where do we go from here?</article-title> <source>Int J Cardiol</source>. (<year>2021</year>) <volume>345</volume>:<fpage>127</fpage>&#x2013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1016/j.ijcard.2021.10.028</pub-id><pub-id pub-id-type="pmid">34687804</pub-id></mixed-citation></ref>
<ref id="B3"><label>3.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Li</surname> <given-names>J</given-names></name> <name><surname>Liu</surname> <given-names>Y</given-names></name> <name><surname>Wu</surname> <given-names>T</given-names></name> <name><surname>Xiao</surname> <given-names>Z</given-names></name> <name><surname>Du</surname> <given-names>J</given-names></name> <name><surname>Liang</surname> <given-names>H</given-names></name><etal/></person-group> <article-title>Barbed arrow-like structure membrane with ultra-high rectification coefficient enables ultra-fast, highly-sensitive lateral-flow assay of cTnI</article-title>. <source>Nat Commun</source>. (<year>2024</year>) <volume>15</volume>(<issue>1</issue>):<fpage>5603</fpage>. <pub-id pub-id-type="doi">10.1038/s41467-024-49810-z</pub-id><pub-id pub-id-type="pmid">38961073</pub-id></mixed-citation></ref>
<ref id="B4"><label>4.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Neumann</surname> <given-names>JT</given-names></name> <name><surname>Twerenbold</surname> <given-names>R</given-names></name> <name><surname>Weimann</surname> <given-names>J</given-names></name> <name><surname>Ballantyne</surname> <given-names>CM</given-names></name> <name><surname>Benjamin</surname> <given-names>EJ</given-names></name> <name><surname>Costanzo</surname> <given-names>S</given-names></name><etal/></person-group> <article-title>Prognostic value of cardiovascular biomarkers in the population</article-title>. <source>JAMA</source>. (<year>2024</year>) <volume>331</volume>(<issue>22</issue>):<fpage>1898</fpage>&#x2013;<lpage>909</lpage>. <pub-id pub-id-type="doi">10.1001/jama.2024.5596</pub-id><pub-id pub-id-type="pmid">38739396</pub-id></mixed-citation></ref>
<ref id="B5"><label>5.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Farmakis</surname> <given-names>D</given-names></name> <name><surname>Mueller</surname> <given-names>C</given-names></name> <name><surname>Apple</surname> <given-names>FS</given-names></name></person-group>. <article-title>High-sensitivity cardiac troponin assays for cardiovascular risk stratification in the general population</article-title>. <source>Eur Heart J</source>. (<year>2020</year>) <volume>41</volume>(<issue>41</issue>):<fpage>4050</fpage>&#x2013;<lpage>6</lpage>. <pub-id pub-id-type="doi">10.1093/eurheartj/ehaa083</pub-id><pub-id pub-id-type="pmid">32077940</pub-id></mixed-citation></ref>
<ref id="B6"><label>6.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Thygesen</surname> <given-names>K</given-names></name></person-group>. <article-title>&#x201C;Ten commandments&#x201D; for the fourth universal definition of myocardial infarction 2018</article-title>. <source>Eur Heart J</source>. (<year>2019</year>) <volume>40</volume>(<issue>3</issue>):<fpage>226</fpage>. <pub-id pub-id-type="doi">10.1093/eurheartj/ehy856</pub-id><pub-id pub-id-type="pmid">30649367</pub-id></mixed-citation></ref>
<ref id="B7"><label>7.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Apple</surname> <given-names>FS</given-names></name> <name><surname>Collinson</surname> <given-names>PO</given-names></name></person-group>, <collab>IFCC Task Force on Clinical Applications of Cardiac Biomarkers</collab>. <article-title>Analytical characteristics of high-sensitivity cardiac troponin assays</article-title>. <source>Clin Chem</source>. (<year>2012</year>) <volume>58</volume>(<issue>1</issue>):<fpage>54</fpage>&#x2013;<lpage>61</lpage>. <pub-id pub-id-type="doi">10.1373/clinchem.2011.165795</pub-id>. <comment>Erratum in: Clin Chem. 2012 Apr;58(4):796</comment>.<pub-id pub-id-type="pmid">21965555</pub-id></mixed-citation></ref>
<ref id="B8"><label>8.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Cullen</surname> <given-names>L</given-names></name> <name><surname>Greenslade</surname> <given-names>J</given-names></name> <name><surname>Parsonage</surname> <given-names>W</given-names></name> <name><surname>Stephensen</surname> <given-names>L</given-names></name> <name><surname>Smith</surname> <given-names>SW</given-names></name> <name><surname>Sandoval</surname> <given-names>Y</given-names></name><etal/></person-group> <article-title>Point-of-care high-sensitivity cardiac troponin in suspected acute myocardial infarction assessed at baseline and 2&#x2005;h</article-title>. <source>Eur Heart J</source>. (<year>2024</year>) <volume>45</volume>(<issue>28</issue>):<fpage>2508</fpage>&#x2013;<lpage>15</lpage>. <pub-id pub-id-type="doi">10.1093/eurheartj/ehae343</pub-id><pub-id pub-id-type="pmid">38842324</pub-id></mixed-citation></ref>
<ref id="B9"><label>9.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Albaqami</surname> <given-names>B</given-names></name> <name><surname>Dinnes</surname> <given-names>J</given-names></name> <name><surname>Moore</surname> <given-names>TH</given-names></name> <name><surname>Kirby</surname> <given-names>K</given-names></name> <name><surname>Carley</surname> <given-names>SD</given-names></name> <name><surname>Aloufi</surname> <given-names>M</given-names></name><etal/></person-group> <article-title>Point-of-care troponin tests to rule out acute myocardial infarction in the prehospital environment: a protocol for a systematic review and meta-analysis</article-title>. <source>BMJ Open</source>. (<year>2025</year>) <volume>15</volume>(<issue>5</issue>):<fpage>e094390</fpage>. <pub-id pub-id-type="doi">10.1136/bmjopen-2024-094390</pub-id><pub-id pub-id-type="pmid">40316349</pub-id></mixed-citation></ref>
<ref id="B10"><label>10.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Crapnell</surname> <given-names>RD</given-names></name> <name><surname>Dempsey</surname> <given-names>NC</given-names></name> <name><surname>Sigley</surname> <given-names>E</given-names></name> <name><surname>Tridente</surname> <given-names>A</given-names></name> <name><surname>Banks</surname> <given-names>CE</given-names></name></person-group>. <article-title>Electroanalytical point-of-care detection of gold standard and emerging cardiac biomarkers for stratification and monitoring in intensive care medicine&#x2014;a review</article-title>. <source>Mikrochim Acta</source>. (<year>2022</year>) <volume>189</volume>(<issue>4</issue>):<fpage>142</fpage>. <pub-id pub-id-type="doi">10.1007/s00604-022-05186-9</pub-id><pub-id pub-id-type="pmid">35279780</pub-id></mixed-citation></ref>
<ref id="B11"><label>11.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Maisel</surname> <given-names>AS</given-names></name> <name><surname>Krishnaswamy</surname> <given-names>P</given-names></name> <name><surname>Nowak</surname> <given-names>RM</given-names></name> <name><surname>McCord</surname> <given-names>J</given-names></name> <name><surname>Hollander</surname> <given-names>JE</given-names></name> <name><surname>Duc</surname> <given-names>P</given-names></name><etal/></person-group> <article-title>Rapid measurement of B-type natriuretic peptide in the emergency diagnosis of heart failure</article-title>. <source>N Engl J Med</source>. (<year>2002</year>) <volume>347</volume>(<issue>3</issue>):<fpage>161</fpage>&#x2013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1056/NEJMoa020233</pub-id><pub-id pub-id-type="pmid">12124404</pub-id></mixed-citation></ref>
<ref id="B12"><label>12.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Richards</surname> <given-names>M</given-names></name> <name><surname>Troughton</surname> <given-names>RW</given-names></name></person-group>. <article-title>NT-proBNP in heart failure: therapy decisions and monitoring</article-title>. <source>Eur J Heart Fail</source>. (<year>2004</year>) <volume>6</volume>(<issue>3</issue>):<fpage>351</fpage>&#x2013;<lpage>4</lpage>. <pub-id pub-id-type="doi">10.1016/j.ejheart.2004.01.003</pub-id><pub-id pub-id-type="pmid">14987587</pub-id></mixed-citation></ref>
<ref id="B13"><label>13.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Lloyd-Jones</surname> <given-names>DM</given-names></name> <name><surname>Braun</surname> <given-names>LT</given-names></name> <name><surname>Ndumele</surname> <given-names>CE</given-names></name> <name><surname>Smith</surname><given-names>SC</given-names><suffix>Jr</suffix></name> <name><surname>Sperling</surname> <given-names>LS</given-names></name> <name><surname>Virani</surname> <given-names>SS</given-names></name><etal/></person-group> <article-title>Use of risk assessment tools to guide decision-making in the primary prevention of atherosclerotic cardiovascular disease: a special report from the American Heart Association and American College of Cardiology</article-title>. <source>Circulation</source>. (<year>2019</year>) <volume>139</volume>(<issue>25</issue>):<fpage>e1162</fpage>&#x2013;<lpage>77</lpage>. <pub-id pub-id-type="doi">10.1161/CIR.0000000000000638</pub-id>. <comment>Erratum in: Circulation. 2019 Jun 18;139(25):e1188. doi: 10.1161/CIR.0000000000000701</comment>.<pub-id pub-id-type="pmid">30586766</pub-id></mixed-citation></ref>
<ref id="B14"><label>14.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Wang</surname> <given-names>TJ</given-names></name> <name><surname>Gona</surname> <given-names>P</given-names></name> <name><surname>Larson</surname> <given-names>MG</given-names></name> <name><surname>Tofler</surname> <given-names>GH</given-names></name> <name><surname>Levy</surname> <given-names>D</given-names></name> <name><surname>Newton-Cheh</surname> <given-names>C</given-names></name><etal/></person-group> <article-title>Multiple biomarkers for the prediction of first major cardiovascular events and death</article-title>. <source>N Engl J Med</source>. (<year>2006</year>) <volume>355</volume>(<issue>25</issue>):<fpage>2631</fpage>&#x2013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1056/NEJMoa055373</pub-id><pub-id pub-id-type="pmid">17182988</pub-id></mixed-citation></ref>
<ref id="B15"><label>15.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Cook</surname> <given-names>NR</given-names></name> <name><surname>Buring</surname> <given-names>JE</given-names></name> <name><surname>Ridker</surname> <given-names>PM</given-names></name></person-group>. <article-title>The effect of including C-reactive protein in cardiovascular risk prediction models for women</article-title>. <source>Ann Intern Med</source>. (<year>2006</year>) <volume>145</volume>(<issue>1</issue>):<fpage>21</fpage>&#x2013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.7326/0003-4819-145-1-200607040-00128</pub-id><pub-id pub-id-type="pmid">16818925</pub-id></mixed-citation></ref>
<ref id="B16"><label>16.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Collinson</surname> <given-names>P</given-names></name></person-group>. <article-title>High sensitivity troponin, analytical advantages, clinical benefits and clinical challenges&#x2014;an update</article-title>. <source>Clin Biochem</source>. (<year>2021</year>) <volume>91</volume>:<fpage>1</fpage>&#x2013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1016/j.clinbiochem.2021.02.001</pub-id><pub-id pub-id-type="pmid">33610525</pub-id></mixed-citation></ref>
<ref id="B17"><label>17.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Newby</surname> <given-names>LK</given-names></name> <name><surname>Jesse</surname> <given-names>RL</given-names></name> <name><surname>Babb</surname> <given-names>JD</given-names></name> <name><surname>Christenson</surname> <given-names>RH</given-names></name> <name><surname>De Fer</surname> <given-names>TM</given-names></name> <name><surname>Diamond</surname> <given-names>GA</given-names></name><etal/></person-group> <article-title>ACCF 2012 expert consensus document on practical clinical considerations in the interpretation of troponin elevations: a report of the American College of Cardiology foundation task force on Clinical Expert Consensus Documents</article-title>. <source>J Am Coll Cardiol</source>. (<year>2012</year>) <volume>60</volume>(<issue>23</issue>):<fpage>2427</fpage>&#x2013;<lpage>63</lpage>. <pub-id pub-id-type="doi">10.1016/j.jacc.2012.08.969</pub-id><pub-id pub-id-type="pmid">23154053</pub-id></mixed-citation></ref>
<ref id="B18"><label>18.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Quesada-Gonz&#x00E1;lez</surname> <given-names>D</given-names></name> <name><surname>Merko&#x00E7;i</surname> <given-names>A</given-names></name></person-group>. <article-title>Nanomaterial-based devices for point-of-care diagnostic applications</article-title>. <source>Chem Soc Rev</source>. (<year>2018</year>) <volume>47</volume>(<issue>13</issue>):<fpage>4697</fpage>&#x2013;<lpage>709</lpage>. <pub-id pub-id-type="doi">10.1039/c7cs00837f</pub-id></mixed-citation></ref>
<ref id="B19"><label>19.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Tripathi</surname> <given-names>A</given-names></name> <name><surname>Bonilla-Cruz</surname> <given-names>J</given-names></name></person-group>. <article-title>Review on healthcare biosensing nanomaterials</article-title>. <source>ACS Appl Nano Mater</source>. (<year>2023</year>) <volume>6</volume>(<issue>7</issue>):<fpage>5042</fpage>&#x2013;<lpage>74</lpage>. <pub-id pub-id-type="doi">10.1021/acsanm.3c00941</pub-id></mixed-citation></ref>
<ref id="B20"><label>20.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Gao</surname> <given-names>F</given-names></name> <name><surname>Ye</surname> <given-names>S</given-names></name> <name><surname>Huang</surname> <given-names>L</given-names></name> <name><surname>Gu</surname> <given-names>Z</given-names></name></person-group>. <article-title>A nanoparticle-assisted signal-enhancement technique for lateral flow immunoassays</article-title>. <source>J Mater Chem B</source>. (<year>2024</year>) <volume>12</volume>(<issue>28</issue>):<fpage>6735</fpage>&#x2013;<lpage>56</lpage>. <pub-id pub-id-type="doi">10.1039/d4tb00865k</pub-id><pub-id pub-id-type="pmid">38920348</pub-id></mixed-citation></ref>
<ref id="B21"><label>21.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Budd</surname> <given-names>J</given-names></name> <name><surname>Miller</surname> <given-names>BS</given-names></name> <name><surname>Weckman</surname> <given-names>NE</given-names></name> <name><surname>Cherkaoui</surname> <given-names>D</given-names></name> <name><surname>Huang</surname> <given-names>D</given-names></name> <name><surname>Decruz</surname> <given-names>AT</given-names></name><etal/></person-group> <article-title>Lateral flow test engineering and lessons learned from COVID-19</article-title>. <source>Nat Rev Bioeng</source>. (<year>2023</year>) <volume>1</volume>:<fpage>13</fpage>&#x2013;<lpage>31</lpage>.</mixed-citation></ref>
<ref id="B22"><label>22.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Naseri</surname> <given-names>M</given-names></name> <name><surname>Ziora</surname> <given-names>ZM</given-names></name> <name><surname>Simon</surname> <given-names>GP</given-names></name> <name><surname>Batchelor</surname> <given-names>W</given-names></name></person-group>. <article-title>ASSURED-Compliant point-of-care diagnostics for the detection of human viral infections</article-title>. <source>Rev Med Virol</source>. (<year>2022</year>) <volume>32</volume>:<fpage>e2263</fpage>. <pub-id pub-id-type="doi">10.1002/rmv.2263</pub-id></mixed-citation></ref>
<ref id="B23"><label>23.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Sadeghi</surname> <given-names>P</given-names></name> <name><surname>Sohrabi</surname> <given-names>H</given-names></name> <name><surname>Hejazi</surname> <given-names>M</given-names></name> <name><surname>Jahanban-Esfahlan</surname> <given-names>A</given-names></name> <name><surname>Baradaran</surname> <given-names>B</given-names></name> <name><surname>Tohidast</surname> <given-names>M</given-names></name><etal/></person-group> <article-title>Lateral flow assays (LFA) as an alternative medical diagnosis method for detection of virus species: the intertwine of nanotechnology with sensing strategies</article-title>. <source>Trends Analyt Chem</source>. (<year>2021</year>) <volume>145</volume>:<fpage>116460</fpage>. <pub-id pub-id-type="doi">10.1016/j.trac.2021.116460</pub-id><pub-id pub-id-type="pmid">34697511</pub-id></mixed-citation></ref>
<ref id="B24"><label>24.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Zheng</surname> <given-names>C</given-names></name> <name><surname>Wang</surname> <given-names>K</given-names></name> <name><surname>Zheng</surname> <given-names>W</given-names></name> <name><surname>Cheng</surname> <given-names>Y</given-names></name> <name><surname>Li</surname> <given-names>T</given-names></name> <name><surname>Cao</surname> <given-names>B</given-names></name><etal/></person-group> <article-title>Rapid developments in lateral flow immunoassay for nucleic acid detection</article-title>. <source>Analyst</source>. (<year>2021</year>) <volume>146</volume>(<issue>5</issue>):<fpage>1514</fpage>&#x2013;<lpage>28</lpage>. <pub-id pub-id-type="doi">10.1039/d0an02150d</pub-id><pub-id pub-id-type="pmid">33595550</pub-id></mixed-citation></ref>
<ref id="B25"><label>25.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Khelifa</surname> <given-names>L</given-names></name> <name><surname>Hu</surname> <given-names>Y</given-names></name> <name><surname>Jiang</surname> <given-names>N</given-names></name> <name><surname>Yetisen</surname> <given-names>AK</given-names></name></person-group>. <article-title>Lateral flow assays for hormone detection</article-title>. <source>Lab Chip</source>. (<year>2022</year>) <volume>22</volume>(<issue>13</issue>):<fpage>2451</fpage>&#x2013;<lpage>75</lpage>. <pub-id pub-id-type="doi">10.1039/d1lc00960e</pub-id><pub-id pub-id-type="pmid">35713489</pub-id></mixed-citation></ref>
<ref id="B26"><label>26.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Mazur</surname> <given-names>F</given-names></name> <name><surname>Tjandra</surname> <given-names>AD</given-names></name> <name><surname>Zhou</surname> <given-names>Y</given-names></name> <name><surname>Gao</surname> <given-names>Y</given-names></name> <name><surname>Chandrawati</surname> <given-names>R</given-names></name></person-group>. <article-title>Paper-based sensors for bacteria detection</article-title>. <source>Nat Rev Bioeng</source>. (<year>2023</year>) <volume>1</volume>(<issue>3</issue>):<fpage>180</fpage>&#x2013;<lpage>92</lpage>. <pub-id pub-id-type="doi">10.1038/s44222-023-00024-w</pub-id><pub-id pub-id-type="pmid">36937095</pub-id></mixed-citation></ref>
<ref id="B27"><label>27.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Sohrabi</surname> <given-names>H</given-names></name> <name><surname>Majidi</surname> <given-names>MR</given-names></name> <name><surname>Khaki</surname> <given-names>P</given-names></name> <name><surname>Jahanban-Esfahlan</surname> <given-names>A</given-names></name> <name><surname>de la Guardia</surname> <given-names>M</given-names></name> <name><surname>Mokhtarzadeh</surname> <given-names>A</given-names></name></person-group>. <article-title>State of the art: lateral flow assays toward the point-of-care foodborne pathogenic bacteria detection in food samples</article-title>. <source>Compr Rev Food Sci Food Saf</source>. (<year>2022</year>) <volume>21</volume>(<issue>2</issue>):<fpage>1868</fpage>&#x2013;<lpage>912</lpage>. <pub-id pub-id-type="doi">10.1111/1541-4337.12913</pub-id><pub-id pub-id-type="pmid">35194932</pub-id></mixed-citation></ref>
<ref id="B28"><label>28.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Chen</surname> <given-names>F</given-names></name> <name><surname>Hu</surname> <given-names>Q</given-names></name> <name><surname>Li</surname> <given-names>H</given-names></name> <name><surname>Xie</surname> <given-names>Y</given-names></name> <name><surname>Xiu</surname> <given-names>L</given-names></name> <name><surname>Zhang</surname> <given-names>Y</given-names></name><etal/></person-group> <article-title>Multiplex detection of infectious diseases on microfluidic platforms</article-title>. <source>Biosensors (Basel)</source>. (<year>2023</year>) <volume>13</volume>(<issue>3</issue>):<fpage>410</fpage>. <pub-id pub-id-type="doi">10.3390/bios13030410</pub-id><pub-id pub-id-type="pmid">36979622</pub-id></mixed-citation></ref>
<ref id="B29"><label>29.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Zhang</surname> <given-names>L</given-names></name> <name><surname>Jiang</surname> <given-names>H</given-names></name> <name><surname>Zhu</surname> <given-names>Z</given-names></name> <name><surname>Liu</surname> <given-names>J</given-names></name> <name><surname>Li</surname> <given-names>B</given-names></name></person-group>. <article-title>Integrating CRISPR/Cas within isothermal amplification for point-of-care assay of nucleic acid</article-title>. <source>Talanta</source>. (<year>2022</year>) <volume>243</volume>:<fpage>123388</fpage>. <pub-id pub-id-type="doi">10.1016/j.talanta.2022.123388</pub-id><pub-id pub-id-type="pmid">35303554</pub-id></mixed-citation></ref>
<ref id="B30"><label>30.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>He</surname> <given-names>W</given-names></name> <name><surname>Wang</surname> <given-names>M</given-names></name> <name><surname>Cheng</surname> <given-names>P</given-names></name> <name><surname>Liu</surname> <given-names>Y</given-names></name> <name><surname>You</surname> <given-names>M</given-names></name></person-group>. <article-title>Recent advances of upconversion nanoparticles-based lateral flow assays for point-of-care testing</article-title>. <source>TrAC, Trends Anal Chem</source>. (<year>2024</year>) <volume>176</volume>:<fpage>117735</fpage>.</mixed-citation></ref>
<ref id="B31"><label>31.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Hou</surname> <given-names>F</given-names></name> <name><surname>Sun</surname> <given-names>S</given-names></name> <name><surname>Abdullah</surname> <given-names>SW</given-names></name> <name><surname>Tang</surname> <given-names>Y</given-names></name> <name><surname>Li</surname> <given-names>X</given-names></name> <name><surname>Guo</surname> <given-names>H</given-names></name></person-group>. <article-title>The application of nanoparticles in point-of-care testing (POCT) immunoassays</article-title>. <source>Anal Methods</source>. (<year>2023</year>) <volume>15</volume>(<issue>18</issue>):<fpage>2154</fpage>&#x2013;<lpage>80</lpage>. <pub-id pub-id-type="doi">10.1039/d3ay00182b</pub-id><pub-id pub-id-type="pmid">37114768</pub-id></mixed-citation></ref>
<ref id="B32"><label>32.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Hu</surname> <given-names>R</given-names></name> <name><surname>Liao</surname> <given-names>T</given-names></name> <name><surname>Ren</surname> <given-names>Y</given-names></name> <name><surname>Liu</surname> <given-names>W</given-names></name> <name><surname>Ma</surname> <given-names>R</given-names></name> <name><surname>Wang</surname> <given-names>X</given-names></name><etal/></person-group> <article-title>Sensitively detecting antigen of SARS-CoV-2 by NIR-II fluorescent nanoparticles</article-title>. <source>Nano Res</source>. (<year>2022</year>) <volume>15</volume>(<issue>8</issue>):<fpage>7313</fpage>&#x2013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1007/s12274-022-4351-1</pub-id><pub-id pub-id-type="pmid">35571588</pub-id></mixed-citation></ref>
<ref id="B33"><label>33.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Wang</surname> <given-names>D</given-names></name> <name><surname>He</surname> <given-names>S</given-names></name> <name><surname>Wang</surname> <given-names>X</given-names></name> <name><surname>Yan</surname> <given-names>Y</given-names></name> <name><surname>Liu</surname> <given-names>J</given-names></name> <name><surname>Wu</surname> <given-names>S</given-names></name><etal/></person-group> <article-title>Rapid lateral flow immunoassay for the fluorescence detection of SARS-CoV-2 RNA</article-title>. <source>Nat Biomed Eng</source>. (<year>2020</year>) <volume>4</volume>(<issue>12</issue>):<fpage>1150</fpage>&#x2013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1038/s41551-020-00655-z</pub-id><pub-id pub-id-type="pmid">33273714</pub-id></mixed-citation></ref>
<ref id="B34"><label>34.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Bian</surname> <given-names>L</given-names></name> <name><surname>Li</surname> <given-names>Z</given-names></name> <name><surname>He</surname> <given-names>A</given-names></name> <name><surname>Wu</surname> <given-names>B</given-names></name> <name><surname>Yang</surname> <given-names>H</given-names></name> <name><surname>Wu</surname> <given-names>Y</given-names></name><etal/></person-group> <article-title>Ultrabright nanoparticle-labeled lateral flow immunoassay for detection of anti-SARS-CoV-2 neutralizing antibodies in human serum</article-title>. <source>Biomaterials</source>. (<year>2022</year>) <volume>288</volume>:<fpage>121694</fpage>. <pub-id pub-id-type="doi">10.1016/j.biomaterials.2022.121694</pub-id><pub-id pub-id-type="pmid">35977850</pub-id></mixed-citation></ref>
<ref id="B35"><label>35.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Hou</surname> <given-names>J</given-names></name> <name><surname>Cao</surname> <given-names>Y</given-names></name> <name><surname>Deng</surname> <given-names>Q</given-names></name> <name><surname>Zhang</surname> <given-names>Q</given-names></name> <name><surname>Deng</surname> <given-names>X</given-names></name> <name><surname>Chen</surname> <given-names>Z</given-names></name><etal/></person-group> <article-title>A fluorescence-based immunochromatographic assay using quantum dot-encapsulated nanoparticles for the rapid and sensitive detection of fetuin-B</article-title>. <source>Anal Chim Acta</source>. (<year>2024</year>) <volume>1288</volume>:<fpage>342143</fpage>. <pub-id pub-id-type="doi">10.1016/j.aca.2023.342143</pub-id><pub-id pub-id-type="pmid">38220278</pub-id></mixed-citation></ref>
<ref id="B36"><label>36.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Gopal</surname> <given-names>A</given-names></name> <name><surname>Yan</surname> <given-names>L</given-names></name> <name><surname>Kashif</surname> <given-names>S</given-names></name> <name><surname>Munshi</surname> <given-names>T</given-names></name> <name><surname>Roy</surname> <given-names>VAL</given-names></name> <name><surname>Voelcker</surname> <given-names>NH</given-names></name> <name><surname>Chen</surname> <given-names>X</given-names></name></person-group>. <article-title>Biosensors and point-of-care devices for bacterial detection: rapid diagnostics informing antibiotic therapy</article-title>. <source>Adv Healthc Mater</source>. (<year>2022</year>) <volume>11</volume>(<issue>3</issue>):<fpage>e2101546</fpage>. <pub-id pub-id-type="doi">10.1002/adhm.202101546</pub-id><pub-id pub-id-type="pmid">34850601</pub-id></mixed-citation></ref>
<ref id="B37"><label>37.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Januzzi</surname> <given-names>JL</given-names></name> <name><surname>van Kimmenade</surname> <given-names>R</given-names></name> <name><surname>Lainchbury</surname> <given-names>J</given-names></name> <name><surname>Bayes-Genis</surname> <given-names>A</given-names></name> <name><surname>Ordonez-Llanos</surname> <given-names>J</given-names></name> <name><surname>Santalo-Bel</surname> <given-names>M</given-names></name><etal/></person-group> <article-title>NT-proBNP testing for diagnosis and short-term prognosis in acute destabilized heart failure: an international pooled analysis of 1256 patients: the International Collaborative of NT-proBNP Study</article-title>. <source>Eur Heart J</source>. (<year>2006</year>) <volume>27</volume>(<issue>3</issue>):<fpage>330</fpage>&#x2013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1093/eurheartj/ehi631</pub-id><pub-id pub-id-type="pmid">16293638</pub-id></mixed-citation></ref>
<ref id="B38"><label>38.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ridker</surname> <given-names>PM</given-names></name> <name><surname>Everett</surname> <given-names>BM</given-names></name> <name><surname>Thuren</surname> <given-names>T</given-names></name> <name><surname>MacFadyen</surname> <given-names>JG</given-names></name> <name><surname>Chang</surname> <given-names>WH</given-names></name> <name><surname>Ballantyne</surname> <given-names>C</given-names></name><etal/></person-group> <article-title>Antiinflammatory therapy with canakinumab for atherosclerotic disease</article-title>. <source>N Engl J Med</source>. (<year>2017</year>) <volume>377</volume>(<issue>12</issue>):<fpage>1119</fpage>&#x2013;<lpage>31</lpage>. <pub-id pub-id-type="doi">10.1056/NEJMoa1707914</pub-id><pub-id pub-id-type="pmid">28845751</pub-id></mixed-citation></ref>
<ref id="B39"><label>39.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Westwood</surname> <given-names>M</given-names></name> <name><surname>Ramaekers</surname> <given-names>B</given-names></name> <name><surname>Grimm</surname> <given-names>S</given-names></name> <name><surname>Worthy</surname> <given-names>G</given-names></name> <name><surname>Fayter</surname> <given-names>D</given-names></name> <name><surname>Armstrong</surname> <given-names>N</given-names></name><etal/></person-group> <article-title>High-sensitivity troponin assays for early rule-out of acute myocardial infarction in people with acute chest pain: a systematic review and economic evaluation</article-title>. <source>Health Technol Assess</source>. (<year>2021</year>) <volume>25</volume>(<issue>33</issue>):<fpage>1</fpage>&#x2013;<lpage>276</lpage>. <pub-id pub-id-type="doi">10.3310/hta25330</pub-id><pub-id pub-id-type="pmid">34061019</pub-id></mixed-citation></ref>
<ref id="B40"><label>40.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Khairuddin Md Arshad</surname> <given-names>M</given-names></name> <name><surname>Faris Bin Mohamad Fathil</surname> <given-names>M</given-names></name> <name><surname>CB Gopinath</surname> <given-names>S</given-names></name> <name><surname>Rahim Ruslinda</surname> <given-names>A</given-names></name> <name><surname>Nuzaihan Md Nor</surname> <given-names>M</given-names></name> <name><surname>Yoong Lam</surname> <given-names>H</given-names></name><etal/></person-group> <article-title>Cardiac biomarkers: invasive to non-invasive assessments</article-title>. <source>Curr Med Chem</source>. (<year>2016</year>) <volume>23</volume>(<issue>37</issue>):<fpage>4270</fpage>&#x2013;<lpage>84</lpage>.<pub-id pub-id-type="pmid">27719655</pub-id></mixed-citation></ref>
<ref id="B41"><label>41.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Miller</surname> <given-names>VM</given-names></name> <name><surname>Redfield</surname> <given-names>MM</given-names></name> <name><surname>McConnell</surname> <given-names>JP</given-names></name></person-group>. <article-title>Use of BNP and CRP as biomarkers in assessing cardiovascular disease: diagnosis versus risk</article-title>. <source>Curr Vasc Pharmacol</source>. (<year>2007</year>) <volume>5</volume>(<issue>1</issue>):<fpage>15</fpage>&#x2013;<lpage>25</lpage>.<pub-id pub-id-type="pmid">17266610</pub-id></mixed-citation></ref>
<ref id="B42"><label>42.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Elsaka</surname> <given-names>O</given-names></name></person-group>. <article-title>Recent evidence on biomarkers for predicting cardiovascular events: a comprehensive review</article-title>. <source>J Indian Coll Cardiol</source>. (<year>2025</year>) <volume>15</volume>(<issue>1</issue>):<fpage>1</fpage>&#x2013;<lpage>2</lpage>.</mixed-citation></ref>
<ref id="B43"><label>43.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Howie-Esquivel</surname> <given-names>J</given-names></name> <name><surname>White</surname> <given-names>M</given-names></name></person-group>. <article-title>Biomarkers in acute cardiovascular disease</article-title>. <source>J Cardiovasc Nurs</source>. (<year>2008</year>) <volume>23</volume>(<issue>2</issue>):<fpage>124</fpage>&#x2013;<lpage>31</lpage>.<pub-id pub-id-type="pmid">18382255</pub-id></mixed-citation></ref>
<ref id="B44"><label>44.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Apple</surname> <given-names>FS</given-names></name> <name><surname>Murakami</surname> <given-names>MM</given-names></name> <name><surname>Pearce</surname> <given-names>LA</given-names></name> <name><surname>Herzog</surname> <given-names>CA</given-names></name></person-group>. <article-title>Multi-biomarker risk stratification of N-terminal pro-B-type natriuretic peptide, high-sensitivity C-reactive protein, and cardiac troponin T and I in end-stage renal disease for all-cause death</article-title>. <source>Clin Chem</source>. (<year>2004</year>) <volume>50</volume>(<issue>12</issue>):<fpage>2279</fpage>&#x2013;<lpage>85</lpage>.<pub-id pub-id-type="pmid">15364888</pub-id></mixed-citation></ref>
<ref id="B45"><label>45.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Abdul Rehman</surname> <given-names>S</given-names></name> <name><surname>Khurshid</surname> <given-names>Z</given-names></name> <name><surname>Hussain Niazi</surname> <given-names>F</given-names></name> <name><surname>Naseem</surname> <given-names>M</given-names></name> <name><surname>Al Waddani</surname> <given-names>H</given-names></name> <name><surname>Sahibzada</surname> <given-names>HA</given-names></name><etal/></person-group> <article-title>Role of salivary biomarkers in detection of cardiovascular diseases (CVD)</article-title>. <source>Proteomes</source>. (<year>2017</year>) <volume>5</volume>(<issue>3</issue>):<fpage>21</fpage>.<pub-id pub-id-type="pmid">28783097</pub-id></mixed-citation></ref>
<ref id="B46"><label>46.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Dadu</surname> <given-names>RT</given-names></name> <name><surname>Nambi</surname> <given-names>V</given-names></name> <name><surname>Ballantyne</surname> <given-names>CM</given-names></name></person-group>. <article-title>Developing and assessing cardiovascular biomarkers</article-title>. <source>Transl Res</source>. (<year>2012</year>) <volume>159</volume>(<issue>4</issue>):<fpage>265</fpage>&#x2013;<lpage>76</lpage>.<pub-id pub-id-type="pmid">22424430</pub-id></mixed-citation></ref>
<ref id="B47"><label>47.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Thupakula</surname> <given-names>S</given-names></name> <name><surname>Nimmala</surname> <given-names>SS</given-names></name> <name><surname>Ravula</surname> <given-names>H</given-names></name> <name><surname>Chekuri</surname> <given-names>S</given-names></name> <name><surname>Padiya</surname> <given-names>R</given-names></name></person-group>. <article-title>Emerging biomarkers for the detection of cardiovascular diseases</article-title>. <source>Egyptian Heart J</source>. (<year>2022</year>) <volume>74</volume>(<issue>1</issue>):<fpage>77</fpage>. <pub-id pub-id-type="doi">10.1186/s43044-022-00317-2</pub-id></mixed-citation></ref>
<ref id="B48"><label>48.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Sajid</surname> <given-names>M</given-names></name> <name><surname>Kawde</surname> <given-names>AN</given-names></name> <name><surname>Daud</surname> <given-names>M</given-names></name></person-group>. <article-title>Designs, formats and applications of lateral flow assay: a literature review</article-title>. <source>J Saudi Chem Soc</source>. (<year>2015</year>) <volume>19</volume>(<issue>6</issue>):<fpage>689</fpage>&#x2013;<lpage>705</lpage>.</mixed-citation></ref>
<ref id="B49"><label>49.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Bahad&#x0131;r</surname> <given-names>EB</given-names></name> <name><surname>Sezgint&#x00FC;rk</surname> <given-names>MK</given-names></name></person-group>. <article-title>Lateral flow assays: principles, designs and labels</article-title>. <source>TrAC, Trends Anal Chem</source>. (<year>2016</year>) <volume>82</volume>:<fpage>286</fpage>&#x2013;<lpage>306</lpage>.</mixed-citation></ref>
<ref id="B50"><label>50.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Hu</surname> <given-names>J</given-names></name> <name><surname>Wang</surname> <given-names>S</given-names></name> <name><surname>Wang</surname> <given-names>L</given-names></name> <name><surname>Li</surname> <given-names>F</given-names></name> <name><surname>Pingguan-Murphy</surname> <given-names>B</given-names></name> <name><surname>Lu</surname> <given-names>TJ</given-names></name><etal/></person-group> <article-title>Advances in paper-based point-of-care diagnostics</article-title>. <source>Biosens Bioelectron</source>. (<year>2014</year>) <volume>54</volume>:<fpage>585</fpage>&#x2013;<lpage>97</lpage>. <pub-id pub-id-type="doi">10.1016/j.bios.2013.10.075</pub-id><pub-id pub-id-type="pmid">24333570</pub-id></mixed-citation></ref>
<ref id="B51"><label>51.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Posthuma-Trumpie</surname> <given-names>GA</given-names></name> <name><surname>Korf</surname> <given-names>J</given-names></name> <name><surname>van Amerongen</surname> <given-names>A</given-names></name></person-group>. <article-title>Lateral flow (immuno)assay: its strengths, weaknesses, opportunities and threats: a review</article-title>. <source>Anal Bioanal Chem</source>. (<year>2009</year>) <volume>393</volume>(<issue>2</issue>):<fpage>569</fpage>&#x2013;<lpage>82</lpage>.<pub-id pub-id-type="pmid">18696055</pub-id></mixed-citation></ref>
<ref id="B52"><label>52.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Choi</surname> <given-names>JR</given-names></name><etal/></person-group> <article-title>Point-of-care testing (POCT) diagnostic systems using lateral fow assay for infectious diseases</article-title>. <source>Analyst</source>. (<year>2019</year>) <volume>144</volume>(<issue>2</issue>):<fpage>331</fpage>&#x2013;<lpage>45</lpage>.</mixed-citation></ref>
<ref id="B53"><label>53.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ochwo</surname> <given-names>S</given-names></name> <name><surname>Perez</surname> <given-names>AM</given-names></name> <name><surname>P&#x00E9;rez Aguirreburualde</surname> <given-names>MS</given-names></name></person-group>. <article-title>Beyond accuracy: leveraging ASSURED criteria for field evaluation of point-of-care tests for food animal diseases</article-title>. <source>Front Vet Sci</source>. (<year>2023</year>) <volume>10</volume>:<fpage>1239111</fpage>. <pub-id pub-id-type="doi">10.3389/fvets.2023.1239111</pub-id><pub-id pub-id-type="pmid">37720479</pub-id></mixed-citation></ref>
<ref id="B54"><label>54.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Posthuma-Trumpie</surname> <given-names>GA</given-names></name> <name><surname>Korf</surname> <given-names>J</given-names></name> <name><surname>van Amerongen</surname> <given-names>A</given-names></name></person-group>. <article-title>Lateral flow (immuno)assay: its strengths, weaknesses, opportunities and threats. A literature survey</article-title>. <source>Anal Bioanal Chem</source>. (<year>2009</year>) <volume>393</volume>(<issue>2</issue>):<fpage>569</fpage>&#x2013;<lpage>82</lpage>. <pub-id pub-id-type="doi">10.1007/s00216-008-2287-2</pub-id><pub-id pub-id-type="pmid">18696055</pub-id></mixed-citation></ref>
<ref id="B55"><label>55.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ridker</surname> <given-names>PM</given-names></name> <name><surname>Brown</surname> <given-names>NJ</given-names></name> <name><surname>Vaughan</surname> <given-names>DE</given-names></name> <name><surname>Harrison</surname> <given-names>DG</given-names></name> <name><surname>Mehta</surname> <given-names>JL</given-names></name></person-group>. <article-title>Established and emerging plasma biomarkers in the prediction of first atherothrombotic events</article-title>. <source>Circulation</source>. (<year>2004</year>) <volume>109</volume>(<issue>25 Suppl 1</issue>):<fpage>IV6-19</fpage>. <pub-id pub-id-type="doi">10.1161/01.CIR.0000133444.17867.56</pub-id><pub-id pub-id-type="pmid">15226246</pub-id></mixed-citation></ref>
<ref id="B56"><label>56.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Shah</surname> <given-names>RV</given-names></name> <name><surname>Abbasi</surname> <given-names>SA</given-names></name> <name><surname>Heydari</surname> <given-names>B</given-names></name> <name><surname>Rickers</surname> <given-names>C</given-names></name> <name><surname>Jacobs</surname><given-names>DR</given-names><suffix>Jr</suffix></name> <name><surname>Wang</surname> <given-names>L</given-names></name><etal/></person-group> <article-title>Insulin resistance, subclinical left ventricular remodeling, and the obesity paradox: MESA (Multi-Ethnic Study of Atherosclerosis)</article-title>. <source>J Am Coll Cardiol</source>. (<year>2013</year>) <volume>61</volume>(<issue>16</issue>):<fpage>1698</fpage>&#x2013;<lpage>706</lpage>. <pub-id pub-id-type="doi">10.1016/j.jacc.2013.01.053</pub-id><pub-id pub-id-type="pmid">23500236</pub-id></mixed-citation></ref>
<ref id="B57"><label>57.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Choi</surname> <given-names>SH</given-names></name> <name><surname>Lee</surname> <given-names>JS</given-names></name> <name><surname>Choi</surname> <given-names>WJ</given-names></name> <name><surname>Seo</surname> <given-names>JW</given-names></name> <name><surname>Choi</surname> <given-names>SJ</given-names></name></person-group>. <article-title>Nanomaterials for IoT sensing platforms and point-of-care applications in South Korea</article-title>. <source>Sensors (Basel)</source>. (<year>2022</year>) <volume>22</volume>(<issue>2</issue>):<fpage>610</fpage>. <pub-id pub-id-type="doi">10.3390/s22020610</pub-id><pub-id pub-id-type="pmid">35062576</pub-id></mixed-citation></ref>
<ref id="B58"><label>58.</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Yager</surname> <given-names>P</given-names></name> <name><surname>Domingo</surname> <given-names>GJ</given-names></name> <name><surname>Gerdes</surname> <given-names>J</given-names></name></person-group>. <article-title>Point-of-care diagnostics for global health</article-title>. <source>Annu Rev Biomed Eng</source>. (<year>2008</year>) <volume>10</volume>:<fpage>107</fpage>&#x2013;<lpage>44</lpage>. <pub-id pub-id-type="doi">10.1146/annurev.bioeng.10.061807.160524</pub-id><pub-id pub-id-type="pmid">18358075</pub-id></mixed-citation></ref></ref-list>
<fn-group>
<fn id="n1" fn-type="custom" custom-type="edited-by"><p>Edited by: <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/2135321/overview">Kuntal Maity</ext-link>, University of Oklahoma, United States</p></fn>
<fn id="n2" fn-type="custom" custom-type="reviewed-by"><p>Reviewed by: <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/2790754/overview">Prakriti Adhikary</ext-link>, University of North Bengal, India</p>
<p><ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/3042185/overview">Biswajit Mahanty</ext-link>, SR University, India</p></fn>
</fn-group>
</back>
</article>