<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="case-report" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xml:lang="EN">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Cardiovasc. Med.</journal-id>
<journal-title>Frontiers in Cardiovascular Medicine</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Cardiovasc. Med.</abbrev-journal-title>
<issn pub-type="epub">2297-055X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fcvm.2023.1135496</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Cardiovascular Medicine</subject>
<subj-group>
<subject>Case Report</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Severe structural valve deterioration after TAVR with ACURATE Neo: report of two cases</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author"><name><surname>Schaeffer</surname><given-names>Thibault</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/2156704/overview"/></contrib>
<contrib contrib-type="author"><name><surname>Koechlin</surname><given-names>Luca</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib>
<contrib contrib-type="author"><name><surname>Jeger</surname><given-names>Raban</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib>
<contrib contrib-type="author"><name><surname>Leibundgut</surname><given-names>Gregor</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib>
<contrib contrib-type="author" corresp="yes"><name><surname>Reuthebuch</surname><given-names>Oliver</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="corresp" rid="cor1">&#x002A;</xref><uri xlink:href="https://loop.frontiersin.org/people/2203336/overview" /></contrib>
</contrib-group>
<aff id="aff1"><label><sup>1</sup></label><addr-line>Department of Cardiac Surgery</addr-line>, <institution>University Hospital Basel, University of Basel</institution>, <addr-line>Basel</addr-line>, <country>Switzerland</country></aff>
<aff id="aff2"><label><sup>2</sup></label><addr-line>Department of Cardiology</addr-line>, <institution>University Hospital Basel, University of Basel</institution>, <addr-line>Basel</addr-line>, <country>Switzerland</country></aff>
<author-notes>
<fn fn-type="edited-by"><p><bold>Edited by:</bold> Verena Veulemans, University Hospital of D&#x00FC;sseldorf, Germany</p></fn>
<fn fn-type="edited-by"><p><bold>Reviewed by:</bold> Francesco Giannini, Maria Cecilia Hospital, Italy Rutger-Jan Nuis, Erasmus Medical Center, Netherlands</p></fn>
<corresp id="cor1"><label>&#x002A;</label><bold>Correspondence:</bold> Oliver Reuthebuch <email>oliver.reuthebuch@usb.ch</email></corresp>
<fn fn-type="other" id="fn001"><p>Abbreviations SVD, structural valve deterioration; BVF, bioprosthetic valve failure; TAVR, transcathter aortic valve replacement; TTE, transthoracic echocardiography; AR, aortic valve regurgitation; TEE, transesophageal echocardiography; SAVR, surgical aortic valve replacement; EAPCI, European Association of Percutaneous Cardiovascular Interventions.</p></fn>
</author-notes>
<pub-date pub-type="epub"><day>25</day><month>05</month><year>2023</year></pub-date>
<pub-date pub-type="collection"><year>2023</year></pub-date>
<volume>10</volume><elocation-id>1135496</elocation-id>
<history>
<date date-type="received"><day>31</day><month>12</month><year>2022</year></date>
<date date-type="accepted"><day>03</day><month>05</month><year>2023</year></date>
</history>
<permissions>
<copyright-statement>&#x00A9; 2023 Schaeffer, Koechlin, Jeger, Leibundgut and Reuthebuch.</copyright-statement>
<copyright-year>2023</copyright-year><copyright-holder>Schaeffer, Koechlin, Jeger, Leibundgut and Reuthebuch</copyright-holder><license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the <ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by/4.0/">Creative Commons Attribution License (CC BY)</ext-link>. The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license>
</permissions>
<abstract>
<p>Structural valve deterioration (SVD) of transcatheter implanted aortic valve (TAVR) prostheses leading to prosthesis dysfunction is an uncommon yet increasingly described complication. Literature is scarce on specific mechanisms and clinical presentation of SVD after TAVR, notably on self-expanding valve ACURATE Neo. We report on two cases with severe bioprosthetic failure after ACURATE Neo implantation due to leaflet disruption, and we treated them with surgical aortic valve replacement. Based on the literature, we further discuss the incidence of SVD after TAVR, the durability of ACURATE NEO, and the modes of failure of biological valve prostheses.</p>
</abstract>
<kwd-group>
<kwd>ACURATE Neo</kwd>
<kwd>TAVR explantation</kwd>
<kwd>structural valve deterioration (SVD)</kwd>
<kwd>bioprosthesis failure</kwd>
<kwd>surgical aortic replacement</kwd>
</kwd-group>
<counts>
<fig-count count="2"/>
<table-count count="2"/><equation-count count="0"/><ref-count count="17"/><page-count count="0"/><word-count count="0"/></counts><custom-meta-wrap><custom-meta><meta-name>section-at-acceptance</meta-name><meta-value>Heart Valve Disease</meta-value></custom-meta></custom-meta-wrap>
</article-meta>
</front>
<body>
<sec id="s1"><label>1.</label><title>Introduction</title>
<p>Structural valve deterioration (SVD) refers to intrinsic alterations of bioprosthetic heart valves such as leaflet fibrosis and/or calcification, leaflet tear, and pannus that eventually lead to their hemodynamic dysfunction. Bioprosthetic failure (BVF) defines any clinically expressive valve dysfunction related to SVD or other conditions, such as endocarditis and prosthetic valve thrombosis, that eventually requires valve reoperation or reintervention (<xref ref-type="bibr" rid="B1">1</xref>). The clinical manifestation of bioprosthetic failure varies according to the severity of valve dysfunction. Literature is scarce on specific mechanisms and clinical presentation of SVD after TAVR, notably on self-expanding valve ACURATE Neo (Boston Scientific, Ecublens, Switzerland). We herein report on two cases with distinct mechanisms of SVD after ACURATE Neo implantation leading to BVF.</p>
</sec>
<sec id="s2"><label>2.</label><title>Case description</title>
<sec id="s2a"><label>2.1.</label><title>Case 1</title>
<p>A 70-year-old man was implanted with ACURATE Neo (size M) for symptomatic, severe aortic valve stenosis. The procedure was unremarkable, and transthoracic echocardiography (TTE) at discharge showed a mean aortic transvalvular aortic gradient of 7&#x2005;mmHg and trivial paravalvular regurgitation. Approximately 4 years (54 months) later, he presented to his regional hospital with rapidly progressive dyspnea. TTE revealed severe aortic valve regurgitation (AR). After transfer to our tertiary center, transesophageal echocardiography (TEE) demonstrated a well-seated TAVR prosthesis with severe intraprosthetic, eccentric AR (see <xref ref-type="fig" rid="F1">Figures&#x00A0;1A</xref>,<xref ref-type="fig" rid="F1">B</xref>). Transvalvular aortic gradients were slightly elevated (mean pressure gradient 18&#x2005;mmHg). Blood cultures were negative. Considering the intermediate surgical risk of the patient, we opted for an emergent TAVR explant and surgical aortic valve replacement (SAVR). Intraoperative inspection of the prosthesis revealed a leaflet disruption with its adjacent strut in the noncoronary position (see <xref ref-type="fig" rid="F1">Figure&#x00A0;1C</xref>). There were no signs of endocarditis. Extraction of the prosthesis was complicated due to extensive pannus arising from the heavily calcified native aortic valve. Due to subsequent lacerations of the aortic annulus, the aortomitral junction was reconstructed with a bovine pericardial patch, and a 23-mm stented bioprosthesis was implanted in the aortic position. The postoperative course was uneventful, and the patient was promptly discharged. After an internal review, the manufacturer was unable to identify the cause of prosthesis dysfunction. According to the manufacturer&#x0027;s archive, the referenced device had passed all tests during manufacturing and met all required specifications before approval for final distribution and sale.</p>
<fig id="F1" position="float"><label>Figure 1</label>
<caption><p>Case 1: transesophageal echocardiography three-chamber view with color-flow Doppler (<bold>A</bold>) and aortic valve-centered short-axis view with color-flow Doppler (<bold>B</bold>) showing an eccentric, severe intraprosthetic regurgitation. (<bold>C</bold>) Explanted ACURATE Neo prosthesis with leaflet disruption with its adjacent strut in the noncoronary position (yellow asterisk).</p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fcvm-10-1135496-g001.tif"/>
</fig>
</sec>
<sec id="s2b"><label>2.2.</label><title>Case 2</title>
<p>An 80-year-old woman was implanted with ACURATE Neo (size S) for symptomatic aortic valve stenosis. Moderate residual AR after valve deployment was immediately addressed with single balloon dilatation. TTE at discharge and at the 1-year routine control showed no significant regurgitation and low transaortic gradients. After barely 2 years (23 months), the patient complained of sudden dyspnea and medication-refractory elevated blood pressure. TTE performed by her cardiologist revealed a severe AR. TEE after admission at our center demonstrated a partial cusp prolapse on the right-coronary position associated with severe, eccentric AR (see <xref ref-type="fig" rid="F2">Figures&#x00A0;2A</xref>,<xref ref-type="fig" rid="F2">B</xref>). Blood cultures were negative. Given the intermediate surgical risk and to prevent coronary obstruction with limited coronary ostium height (13&#x2005;mm on both sides), we opted for a TAVR explant and SAVR. Intraoperative inspection of the prosthesis revealed a central tear in the leaflet in the right-coronary position (see <xref ref-type="fig" rid="F2">Figure&#x00A0;2C</xref>). There were no local signs of endocarditis. The extraction of the prosthesis was complicated due to an extensive pannus and endothelialization of the axial stabilization arches anchored in the aortic wall. After prosthesis removal, we implanted a 21-mm surgical bioprosthesis in the aortic position. The postoperative course was besides transitory acute-on-chronic renal failure uneventful, and the patient was discharged after 10 days. Cases summary as timeline is provided in <xref ref-type="table" rid="T2">Table 2</xref>.</p>
<fig id="F2" position="float"><label>Figure 2</label>
<caption><p>Case 2: transesophageal echocardiography three-chamber view with color-flow Doppler (<bold>A</bold>) and aortic valve-centered short-axis view with color-flow Doppler (<bold>B</bold>) showing severe intraprosthetic regurgitation and partial cusp prolapse (yellow arrow) on the right coronary side, respectively. (<bold>C</bold>) Explanted ACURATE Neo prosthesis with a central tear in the leaflet in the right-coronary position (yellow asterisk).</p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fcvm-10-1135496-g002.tif"/>
</fig>
</sec>
</sec>
<sec id="s3"><label>3.</label><title>Discussion</title>
<p>Data on specific mechanisms of SVD affecting TAVR prostheses, their incidence, and clinical presentation are limited.</p>
<p>The PARTNER-1 (Placement of Aortic Transcatheter Valves) trial (<italic>n</italic>&#x2009;&#x003D;&#x2009;1057) and CoreValve High-Risk Pivotal trial (<italic>n</italic>&#x2009;&#x003D;&#x2009;795) reported extremely low rates of severe SVD with 0&#x0025; and 0.8&#x0025; after 5 years for SAPIEN (Edwards Lifesciences, Irvine, CA, USA) and CoreValve (Medtronic, Minneapolis, MN, USA), respectively (<xref ref-type="bibr" rid="B2">2</xref>, <xref ref-type="bibr" rid="B3">3</xref>). However, interpretation of these findings is limited due to the small number of survivors at 5 years, as predictable with typically elderly and frail patients included in these historical cohorts. With the introduction of standardized criteria for SVD, longer follow-up, and inclusion of younger, lower-risk patients in prospective TAVR trials in recent years, higher rates of SVD were reported. The NOTION (Nordic Aortic Valve Intervention) trial (<italic>n</italic>&#x2009;&#x003D;&#x2009;139), referring to the European Association of Percutaneous Cardiovascular Interventions (EAPCI), reported SVD risk after CoreValve implantation as high as 4.8&#x0025; at 6 years (<xref ref-type="bibr" rid="B4">4</xref>). Analyzing data from the PARTNER-2A trial (<italic>n</italic>&#x2009;&#x003D;&#x2009;1438) and PARTNER-2/SAPIEN-3 Intermediate-Risk registry (<italic>n</italic>&#x2009;&#x003D;&#x2009;891) and referring to the Valve Academic Research Consortium 3 definitions, Pibarot et al<italic>.</italic> reported SVD risks of 3.9&#x0025; and 9.5&#x0025; at 5 years after implantation of Edwards SAPIEN 3 and Edwards SAPIEN XT, respectively (<xref ref-type="bibr" rid="B5">5</xref>). However, the rates of BVF were rather low (1.1&#x0025; and 3.7&#x0025; for Edwards SAPIEN 3 and Edwards SAPIEN XT, respectively). Also, large European retrospective cohort studies on multiple TAVR devices reported 5-year rates of SVD ranging from 2.5&#x0025; to 4.2&#x0025; and low rates of SVD-related BVF according to the EAPCI guidelines (<xref ref-type="bibr" rid="B6">6</xref>, <xref ref-type="bibr" rid="B7">7</xref>). The heterogeneity of the above-mentioned rates of SVD makes their interpretation difficult and can be explained by at least two factors: first, the underestimation of the incidence of SVD given the substantial competitive risk of death in cohorts with a high mortality on short term (e.g., PARTNER-1), and second, the variability of SVD criteria according to the definitions used. An overview of SVD rates reported by the major historical randomized control trials and retrospective cohort studies focusing on TAVR durability is given in <xref ref-type="table" rid="T1">Table&#x00A0;1</xref>.</p>
<table-wrap id="T1" position="float"><label>Table 1</label>
<caption><p>Overview of SVD rates reported by the major historical randomized control trials and retrospective cohort studies focusing on TAVR durability.</p></caption>
<table frame="hsides" rules="groups">
<colgroup>
<col align="left"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
</colgroup>
<thead>
<tr>
<th valign="top" align="left">Author</th>
<th valign="top" align="center">Year</th>
<th valign="top" align="center">Trial/referred trial/register</th>
<th valign="top" align="center">Type of study</th>
<th valign="top" align="center"><italic>n</italic></th>
<th valign="top" align="center">TAVR prosthesis</th>
<th valign="top" align="center">Follow-up (years)</th>
<th valign="top" align="center">SVD<xref ref-type="table-fn" rid="table-fn2"><sup>a</sup></xref> (&#x0025;)</th>
<th valign="top" align="center">BVF (&#x0025;)</th>
<th valign="top" align="center">All-cause mortality (&#x0025;)</th>
<th valign="top" align="center">Definition of SVD</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Kapadia et al.</td>
<td valign="top" align="center">2015</td>
<td valign="top" align="left">PARTNER-1</td>
<td valign="top" align="left">RCT</td>
<td valign="top" align="center">1,057</td>
<td valign="top" align="left">SAPIEN</td>
<td valign="top" align="center">5</td>
<td valign="top" align="center">0.00</td>
<td valign="top" align="center"><italic>NA</italic></td>
<td valign="top" align="center">71.80</td>
<td valign="top" align="left"><italic>NA</italic></td>
</tr>
<tr>
<td valign="top" align="left">Gleason et al.</td>
<td valign="top" align="center">2018</td>
<td valign="top" align="left">CoreValve High-Risk Pivotal</td>
<td valign="top" align="left">RCT</td>
<td valign="top" align="center">391</td>
<td valign="top" align="left">CoreValve</td>
<td valign="top" align="center">5</td>
<td valign="top" align="center">0.8</td>
<td valign="top" align="center"><italic>NA</italic></td>
<td valign="top" align="center">55.00</td>
<td valign="top" align="left">EAPCI</td>
</tr>
<tr>
<td valign="top" align="left">S&#x00F8;ndergaard et al.</td>
<td valign="top" align="center">2019</td>
<td valign="top" align="left">NOTION</td>
<td valign="top" align="left">RCT</td>
<td valign="top" align="center">139</td>
<td valign="top" align="left">CoreValve</td>
<td valign="top" align="center">6</td>
<td valign="top" align="center">4.8</td>
<td valign="top" align="center">6.70&#x0025;</td>
<td valign="top" align="center">42.50</td>
<td valign="top" align="left">EAPCI</td>
</tr>
<tr>
<td valign="top" align="left">Didier et al.</td>
<td valign="top" align="center">2018</td>
<td valign="top" align="left">FRANCE-2</td>
<td valign="top" align="left">Retrospective</td>
<td valign="top" align="center">4,201</td>
<td valign="top" align="left">CoreValve<break/>SAPIEN<break/>SAPIEN XT</td>
<td valign="top" align="center">5</td>
<td valign="top" align="center">2.50</td>
<td valign="top" align="center">NA</td>
<td valign="top" align="center">60.80</td>
<td valign="top" align="left">EAPCI</td>
</tr>
<tr>
<td valign="top" align="left">Durand et al.</td>
<td valign="top" align="center">2019</td>
<td valign="top" align="left">NA</td>
<td valign="top" align="left">Retrospective</td>
<td valign="top" align="center">1,403</td>
<td valign="top" align="left">SAPIEN<break/>SAPIEN XT<break/>CoreValve<break/>Jena</td>
<td valign="top" align="center">5</td>
<td valign="top" align="center">4.2</td>
<td valign="top" align="center">1.90</td>
<td valign="top" align="center">69.00</td>
<td valign="top" align="left">EAPCI</td>
</tr>
<tr>
<td valign="top" align="left" rowspan="2">Pibarot et al.</td>
<td valign="top" align="center" rowspan="2">2020</td>
<td valign="top" align="left" rowspan="2">PARTNER-2A<break/>PARTNER-2/SAPIEN-3</td>
<td valign="top" align="left" rowspan="2">Retrospective</td>
<td valign="top" align="center">774</td>
<td valign="top" align="left">SAPIEN 3</td>
<td valign="top" align="center" rowspan="2">5</td>
<td valign="top" align="center">3.90</td>
<td valign="top" align="center">1.1<xref ref-type="table-fn" rid="table-fn3"><sup>b</sup></xref></td>
<td valign="top" align="center">NA</td>
<td valign="top" align="left">VARC-3</td>
</tr>
<tr>
<td valign="top" align="left">891</td>
<td valign="top" align="left">SAPIEN XT</td>
<td valign="top" align="center">9.50</td>
<td valign="top" align="center">3.7<xref ref-type="table-fn" rid="table-fn3"><sup>b</sup></xref></td>
<td valign="top" align="center">NA</td>
<td valign="top" align="left">VARC-3</td>
</tr>
<tr>
<td valign="top" align="left">Testa et al.</td>
<td valign="top" align="center">2020</td>
<td valign="top" align="left">NA</td>
<td valign="top" align="left">Retrospective</td>
<td valign="top" align="center">990</td>
<td valign="top" align="left">CoreValve</td>
<td valign="top" align="center">8</td>
<td valign="top" align="center">1.6</td>
<td valign="top" align="center">2.50</td>
<td valign="top" align="center">78.30</td>
<td valign="top" align="left">EAPCI</td>
</tr>
<tr>
<td valign="top" align="left" rowspan="2">Tamburino et al.</td>
<td valign="top" align="center" rowspan="2">2020</td>
<td valign="top" align="left" rowspan="2">SCOPE-2</td>
<td valign="top" align="left" rowspan="2">RCT</td>
<td valign="top" align="center">398</td>
<td valign="top" align="left">ACURATE Neo</td>
<td valign="top" align="center" rowspan="2">1</td>
<td valign="top" align="center">10.00</td>
<td valign="top" align="center">0.25<xref ref-type="table-fn" rid="table-fn3"><sup>b</sup></xref></td>
<td valign="top" align="center">13.00</td>
<td valign="top" align="left">VARC-2</td>
</tr>
<tr>
<td valign="top" align="left">398</td>
<td valign="top" align="left">CoreValve Evolut</td>
<td valign="top" align="center">14.00</td>
<td valign="top" align="center">1<xref ref-type="table-fn" rid="table-fn3"><sup>b</sup></xref></td>
<td valign="top" align="center">9.00</td>
<td valign="top" align="left">VARC-2</td>
</tr>
<tr>
<td valign="top" align="left">Siquiera et al.</td>
<td valign="top" align="center">2021</td>
<td valign="top" align="left">NA</td>
<td valign="top" align="left">Retrospective</td>
<td valign="top" align="center">104</td>
<td valign="top" align="left">ACURATE Neo</td>
<td valign="top" align="center">3</td>
<td valign="top" align="center">1.00</td>
<td valign="top" align="center">1<xref ref-type="table-fn" rid="table-fn3"><sup>b</sup></xref></td>
<td valign="top" align="center">20.70</td>
<td valign="top" align="left">VARC-2</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="table-fn1"><p>TAVR, transcatheter aortic valve replacement; SVD, structural valve deterioration; BVF, bioprosthetic valve failure; RCT, randomized controlled trial; VARC, Valve Academic Research Consortium; EAPCI, European Association of Percutaneous Cardiovascular Interventions; NA, not available.</p></fn>
<fn id="table-fn2"><label><sup>a</sup></label><p>For study referring to the EAPCI definition, only severe SVD is reported.</p></fn>
<fn id="table-fn3"><label><sup>b</sup></label><p>Specifically, SVD-related bioprosthetic failure.</p></fn>
</table-wrap-foot>
</table-wrap>
<table-wrap id="T2" position="float"><label>Table 2</label>
<caption><p>Timeline.</p></caption>
<table frame="hsides" rules="groups">
<colgroup>
<col align="left"/>
<col align="left"/>
<col align="center"/>
<col align="left"/>
</colgroup>
<thead>
<tr>
<th valign="top" align="center" colspan="2">Case 1</th>
<th valign="top" align="center" colspan="2">Case 2</th>
</tr>
<tr>
<th valign="top" align="center">Time</th>
<th valign="top" align="center">Event</th>
<th valign="top" align="center">Time</th>
<th valign="top" align="center">Event</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left"><italic>T</italic><sub>0</sub></td>
<td valign="top" align="left">TAVR with ACURATE Neo</td>
<td valign="top" align="center"><italic>T</italic><sub>0</sub></td>
<td valign="top" align="left">TAVR with ACURATE Neo</td>
</tr>
<tr>
<td valign="top" align="left"><italic>T</italic><sub>1&#x2009;</sub>&#x003D;&#x2009;T<sub>0</sub>&#x2009;&#x002B;&#x2009;54 months</td>
<td valign="top" align="left">Hospital admission for rapidly progressive dyspnea/pulmonary edema</td>
<td valign="top" align="center"><italic>T</italic><sub>1&#x2009;</sub>&#x003D;&#x2009;<italic>T</italic><sub>0</sub>&#x2009;&#x002B;&#x2009;23 months</td>
<td valign="top" align="left">Cardiological workup for acute dyspnea and medication-refractory elevated blood pressure</td>
</tr>
<tr>
<td valign="top" align="left"><italic>T</italic><sub>1</sub>&#x2009;&#x002B;&#x2009;7 days</td>
<td valign="top" align="left">TEE reveals eccentric, severe intraprosthetic AR</td>
<td valign="top" align="center"><italic>T</italic><sub>1</sub>&#x2009;&#x002B;&#x2009;15 days</td>
<td valign="top" align="left">TEE reveals severe intraprosthetic AR and partial cusp prolapse</td>
</tr>
<tr>
<td valign="top" align="left"><italic>T</italic><sub>1</sub>&#x2009;&#x002B;&#x2009;9 days</td>
<td valign="top" align="left">Surgical explant of ACURATE Neo, SAVR</td>
<td valign="top" align="center"><italic>T</italic><sub>1</sub>&#x2009;&#x002B;&#x2009;19 days</td>
<td valign="top" align="left">Surgical explant of ACURATE Neo, SAVR</td>
</tr>
<tr>
<td valign="top" align="left"><italic>T</italic><sub>1</sub>&#x2009;&#x002B;&#x2009;22 days</td>
<td valign="top" align="left">Hospital discharge</td>
<td valign="top" align="center"><italic>T</italic><sub>1</sub>&#x2009;&#x002B;&#x2009;29 days</td>
<td valign="top" align="left">Hospital discharge</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="table-fn4"><p>TAVR, transcathter aortic valve replacement; TTE, transthoracic echocardiography; AR, aortic regurgitation; SAVR: surgical valve replacement.</p></fn>
</table-wrap-foot>
</table-wrap>
<p>When looking at surgical registries of SAVR after TAVR (<italic>n</italic>&#x2009;&#x003D;&#x2009;123 and <italic>n</italic>&#x2009;&#x003D;&#x2009;46), SVD accounted for 10&#x0025;&#x2013;15&#x0025; of indications for TAVR explant in two recent retrospective studies (<xref ref-type="bibr" rid="B8">8</xref>, <xref ref-type="bibr" rid="B9">9</xref>).</p>
<p>Since ACURATE Neo is a more recent and less implanted model of the TAVR era, less information is available about long-term outcomes and specific failure mechanisms of this device.</p>
<p>In the SCOPE-2 (Safety and Efficacy Comparison of Two TAVR Systems in a Prospective Randomized Evaluation 2) trial (<italic>n</italic>&#x2009;&#x003D;&#x2009;796), ACURATE Neo was challenged with its self-expandable concurrent Medtronic CoreValve Evolut (<xref ref-type="bibr" rid="B10">10</xref>). The authors observed more frequent cardiac deaths at 1 year (8.4&#x0025; vs. 3.9&#x0025;; <italic>p&#x2009;</italic>&#x003D;&#x2009;0.01), more frequent severe aortic regurgitation in the short term (10&#x0025; vs. 3&#x0025;, <italic>p&#x2009;</italic>&#x003D;&#x2009;0.002), and more frequent structural valve deterioration in the short term (14&#x0025; vs. 6&#x0025;, <italic>p&#x2009;</italic>&#x003D;&#x2009;0.004) with ACURATE Neo. However, structural valve deterioration was no more statistically different after 1 year (10&#x0025; vs. 14&#x0025;, <italic>p&#x2009;</italic>&#x003D;&#x2009;0.25) and the valve-related dysfunction requiring repeat procedure was similarly low in both devices (1&#x0025;, <italic>p&#x2009;</italic>&#x003D;&#x2009;0.99). Reporting on mid- and long-term results after ACURATE Neo implantation (<italic>n</italic>&#x2009;&#x003D;&#x2009;104), Siquiera et al<italic>.</italic> mentioned a single case of SVD-related failure addressed with a <italic>valve-in-valve</italic> procedure (<xref ref-type="bibr" rid="B11">11</xref>). The authors concluded with overall reassuring mid- to long-term outcomes with this device. Findings of the SCOPE-2 trial at 1 year and those of Siquiera et al. are summarized in <xref ref-type="table" rid="T1">Table&#x00A0;1</xref>. In our institution, we observed a rate of SVD-related BVF of 0.84&#x0025;, accounting for the two present cases over the past 5 years, which was similar to the previously mentioned studies. Finally, reviewing the international EXPLANT-TAVR registry (<italic>n</italic>&#x2009;&#x003D;&#x2009;269), Bapat et al<italic>.</italic> noticed six surgical explants of ACURATE Neo (4.5&#x0025; of all self-/mechanically expandable devices), but neither the causes for explant nor the durability of the failed prostheses was specified (<xref ref-type="bibr" rid="B12">12</xref>).</p>
<p>As the number of TAVR in even younger patients increases, the need to manage late complications with TAVR will increase. The number of former implanted and available TAVR models is also increasing. As such, a better understanding of the specific mechanisms of SVD affecting TAVR prostheses is mandatory. Our two cases contribute to increasing knowledge in this area by illustrating two close but specific modes of SVD leading to acute bioprosthetic failure of the ACURATE Neo. A macroscopic examination of the valves revealed no signs of active endocarditis, and the blood cultures were negative. Eubacterial PCR from leaflet samples was not performed to exclude previous endocarditis. Leaflet tear/disruption is a rare yet well-documented mechanism of SVD of surgical bioprostheses, especially those with externally mounted leaflets (<xref ref-type="bibr" rid="B13">13</xref>&#x2013;<xref ref-type="bibr" rid="B16">16</xref>). Leaflet disruption in aortic bioprosthesis occurs abruptly, and the affected patient typically presents with acute, clinically poorly tolerated aortic regurgitation, as in the two present cases. In the absence of endocarditis criteria, we assumed that the rupture of the leaflet was due to mechanical fatigue by an analogous mechanism to that affecting surgical bioprostheses. To the best of our knowledge, this issue with ACURATE Neo has never been reported.</p>
<p>As for therapy, we opted for TAVR explant and SAVR. Our strategy was driven in both cases by the limited experience reported with <italic>valve-in-valve</italic> procedures in failed ACURATE Neo, in the second case by the rather shallow aortic root with subsequent risk of coronary obstruction. Indeed, recent works highlighted the increased risk of coronary obstruction following redo-TAVR with high-profile index bioprosthetic valves such as ACURATE Neo (<xref ref-type="bibr" rid="B17">17</xref>). Further studies are warranted to define the best approach to failed TAVR prostheses with respect to the index model, mode of failure, and patient&#x00B4;s anatomy.</p>
</sec>
</body>
<back>
<sec id="s4" sec-type="data-availability"><title>Data availability statement</title>
<p>The data analyzed in this study is subject to the following licenses/restrictions: Data are available on reasonable request to the corresponding author. Requests to access these datasets should be directed to <email>oliver.reuthebuch@usb.ch</email>.</p>
</sec>
<sec id="s5"><title>Ethics statement</title>
<p>Written informed consent was obtained from both participants for the publication of this case report.</p>
</sec>
<sec id="s6"><title>Author contributions</title>
<p>TS drafted the manuscript and created the figures. All authors were involved in the conceptualization, analysis, and interpretation of the diagnostic data and the management strategy described in the manuscript and approved and co-edited the manuscript for submission in its current form. All authors contributed to the article and approved the submitted version.</p>
</sec>
<sec id="s7" sec-type="COI-statement"><title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec id="s8" sec-type="disclaimer"><title>Publisher&#x0027;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ref-list><title>References</title>
<ref id="B1"><label>1.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>G&#x00E9;n&#x00E9;reux</surname><given-names>P</given-names></name><name><surname>Piazza</surname><given-names>N</given-names></name><name><surname>Alu</surname><given-names>MC</given-names></name><name><surname>Nazif</surname><given-names>T</given-names></name><name><surname>Hahn</surname><given-names>RT</given-names></name><name><surname>Pibarot</surname><given-names>P</given-names></name><etal/></person-group> <article-title>Valve Academic Research Consortium 3: updated endpoint definitions for aortic valve clinical research</article-title>. <source>Eur Heart J</source>. (<year>2021</year>) <volume>42</volume>(<issue>19</issue>):<fpage>1825</fpage>&#x2013;<lpage>57</lpage>. <pub-id pub-id-type="doi">10.1093/eurheartj/ehaa799</pub-id></citation></ref>
<ref id="B2"><label>2.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kapadia</surname><given-names>SR</given-names></name><name><surname>Leon</surname><given-names>MB</given-names></name><name><surname>Makkar</surname><given-names>RR</given-names></name><name><surname>Tuzcu</surname><given-names>EM</given-names></name><name><surname>Svensson</surname><given-names>LG</given-names></name><name><surname>Kodali</surname><given-names>S</given-names></name><etal/></person-group> <article-title>PARTNER Trial investigators. 5-year outcomes of transcatheter aortic valve replacement compared with standard treatment for patients with inoperable aortic stenosis (PARTNER 1): a randomised controlled trial</article-title>. <source>Lancet</source>. (<year>2015</year>) <volume>385</volume>(<issue>9986</issue>):<fpage>2485</fpage>&#x2013;<lpage>91</lpage>. <pub-id pub-id-type="doi">10.1016/S0140-6736(15)60290-2</pub-id><pub-id pub-id-type="pmid">25788231</pub-id></citation></ref>
<ref id="B3"><label>3.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gleason</surname><given-names>TG</given-names></name><name><surname>Reardon</surname><given-names>MJ</given-names></name><name><surname>Popma</surname><given-names>JJ</given-names></name><name><surname>Deeb</surname><given-names>M</given-names></name><name><surname>Yakubov</surname><given-names>SJ</given-names></name><name><surname>Lee</surname><given-names>JS</given-names></name><etal/></person-group> <article-title>5-Year outcomes of self-expanding transcatheter versus surgical aortic valve replacement in high-risk patients</article-title>. <source>J Am Coll Cardiol</source>. (<year>2018</year>) <volume>72</volume>(<issue>22</issue>):<fpage>2687</fpage>&#x2013;<lpage>96</lpage>. <pub-id pub-id-type="doi">10.1016/j.jacc.2018.08.2146</pub-id><pub-id pub-id-type="pmid">30249462</pub-id></citation></ref>
<ref id="B4"><label>4.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>S&#x00F8;ndergaard</surname><given-names>L</given-names></name><name><surname>Ihlemann</surname><given-names>N</given-names></name><name><surname>Capodanno</surname><given-names>D</given-names></name><name><surname>J&#x00F8;rgensen</surname><given-names>TH</given-names></name><name><surname>Nissen</surname><given-names>H</given-names></name><name><surname>Kjeldsen</surname><given-names>BJ</given-names></name><etal/></person-group> <article-title>Durability of transcatheter and surgical bioprosthetic aortic valves in patients at lower surgical risk</article-title>. <source>J Am Coll Cardiol</source>. (<year>2019</year>) <volume>73</volume>(<issue>5</issue>):<fpage>546</fpage>&#x2013;<lpage>53</lpage>. <pub-id pub-id-type="doi">10.1016/j.jacc.2018.10.083</pub-id></citation></ref>
<ref id="B5"><label>5.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pibarot</surname><given-names>P</given-names></name><name><surname>Ternacle</surname><given-names>J</given-names></name><name><surname>Jaber</surname><given-names>WA</given-names></name><name><surname>Salaun</surname><given-names>E</given-names></name><name><surname>Dahou</surname><given-names>A</given-names></name><name><surname>Asch</surname><given-names>FM</given-names></name><etal/></person-group> <article-title>Structural deterioration of transcatheter versus surgical aortic valve bioprostheses in the PARTNER-2 trial</article-title>. <source>J Am Coll Cardiol</source>. (<year>2020</year>) <volume>76</volume>(<issue>16</issue>):<fpage>1830</fpage>&#x2013;<lpage>43</lpage>. <pub-id pub-id-type="doi">10.1016/j.jacc.2020.08.049</pub-id><pub-id pub-id-type="pmid">33059828</pub-id></citation></ref>
<ref id="B6"><label>6.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Didier</surname><given-names>R</given-names></name><name><surname>Eltchaninoff</surname><given-names>H</given-names></name><name><surname>Donzeau-Gouge</surname><given-names>P</given-names></name><name><surname>Chevreul</surname><given-names>K</given-names></name><name><surname>Fajadet</surname><given-names>J</given-names></name><name><surname>Leprince</surname><given-names>P</given-names></name><etal/></person-group> <article-title>Five-year clinical outcome and valve durability after transcatheter aortic valve replacement in high-risk patients</article-title>. <source>Circulation</source>. (<year>2018</year>) <volume>138</volume>(<issue>23</issue>):<fpage>2597</fpage>&#x2013;<lpage>607</lpage>. <pub-id pub-id-type="doi">10.1161/CIRCULATIONAHA.118.036866</pub-id><pub-id pub-id-type="pmid">30571260</pub-id></citation></ref>
<ref id="B7"><label>7.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Durand</surname><given-names>E</given-names></name><name><surname>Sokoloff</surname><given-names>A</given-names></name><name><surname>Urena-Alcazar</surname><given-names>M</given-names></name><name><surname>Chevalier</surname><given-names>B</given-names></name><name><surname>Chassaing</surname><given-names>S</given-names></name><name><surname>Didier</surname><given-names>R</given-names></name><etal/></person-group> <article-title>Assessment of long-term structural deterioration of transcatheter aortic bioprosthetic valves using the new European definition</article-title>. <source>Circ Cardiovasc Interv</source>. (<year>2019</year>) <volume>12</volume>(<issue>4</issue>):<fpage>e007597</fpage>. <pub-id pub-id-type="doi">10.1161/CIRCINTERVENTIONS.118.007597</pub-id><pub-id pub-id-type="pmid">30998397</pub-id></citation></ref>
<ref id="B8"><label>8.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jawitz</surname><given-names>OK</given-names></name><name><surname>Gulack</surname><given-names>BC</given-names></name><name><surname>Grau-Sepulveda</surname><given-names>MV</given-names></name><name><surname>Matsouaka</surname><given-names>RA</given-names></name><name><surname>Mack</surname><given-names>MJ</given-names></name><name><surname>Holmes</surname><given-names>DJ</given-names></name><etal/></person-group> <article-title>Reoperation after transcatheter aortic valve replacement</article-title>. <source>JACC Cardiovasc Interv</source>. (<year>2020</year>) <volume>13</volume>(<issue>13</issue>):<fpage>1515</fpage>&#x2013;<lpage>25</lpage>. <pub-id pub-id-type="doi">10.1016/j.jcin.2020.04.029</pub-id><pub-id pub-id-type="pmid">32535005</pub-id></citation></ref>
<ref id="B9"><label>9.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Brescia</surname><given-names>AA</given-names></name><name><surname>Deeb</surname><given-names>GM</given-names></name><name><surname>Sang</surname><given-names>SLW</given-names></name><name><surname>Tanaka</surname><given-names>D</given-names></name><name><surname>Grossman</surname><given-names>PM</given-names></name><name><surname>Sukulet</surname><given-names>D</given-names></name><etal/></person-group> <article-title>Surgical explantation of transcatheter aortic valve bioprostheses: a statewide experience</article-title>. <source>Circ Cardiovasc Interv</source>. (<year>2021</year>) <volume>14</volume>(<issue>4</issue>):<fpage>e009927</fpage>. <pub-id pub-id-type="doi">10.1161/CIRCINTERVENTIONS.120.009927</pub-id><pub-id pub-id-type="pmid">33719506</pub-id></citation></ref>
<ref id="B10"><label>10.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tamburino</surname><given-names>C</given-names></name><name><surname>Bleiziffer</surname><given-names>S</given-names></name><name><surname>Thiele</surname><given-names>H</given-names></name><name><surname>Scholtz</surname><given-names>S</given-names></name><name><surname>Hildick-Smith</surname><given-names>D</given-names></name><name><surname>Cunningtonet</surname><given-names>M</given-names></name><etal/></person-group> <article-title>Comparison of self-expanding bioprostheses for transcatheter aortic valve replacement in patients with symptomatic severe aortic stenosis: sCOPE 2 randomized clinical trial</article-title>. <source>Circulation</source>. (<year>2020</year>) <volume>142</volume>(<issue>25</issue>):<fpage>2431</fpage>&#x2013;<lpage>42</lpage>. <pub-id pub-id-type="doi">10.1161/CIRCULATIONAHA.120.051547</pub-id><pub-id pub-id-type="pmid">33054367</pub-id></citation></ref>
<ref id="B11"><label>11.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Siqueira</surname><given-names>DA</given-names></name><name><surname>Simonato</surname><given-names>M</given-names></name><name><surname>Ramos</surname><given-names>AA</given-names></name><name><surname>Bignoto</surname><given-names>T</given-names></name><name><surname>Le Bihan</surname><given-names>D</given-names></name><name><surname>Barreto</surname><given-names>RBM</given-names></name><etal/></person-group> <article-title>Mid- to long-term clinical and echocardiographic outcomes after transcatheter aortic valve replacement with a new-generation, self-expandable system</article-title>. <source>Catheter Cardiovasc Interv</source>. (<year>2021</year>) <volume>97</volume>(<issue>1</issue>):<fpage>167</fpage>&#x2013;<lpage>74</lpage>. <pub-id pub-id-type="doi">10.1002/ccd.28999</pub-id><pub-id pub-id-type="pmid">32445607</pub-id></citation></ref>
<ref id="B12"><label>12.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bapat</surname><given-names>VN</given-names></name><name><surname>Zaid</surname><given-names>S</given-names></name><name><surname>Fukuhara</surname><given-names>S</given-names></name><name><surname>Saha</surname><given-names>S</given-names></name><name><surname>Vitanova</surname><given-names>K</given-names></name><name><surname>Kiefer</surname><given-names>P</given-names></name><etal/></person-group> <article-title>Surgical explantation after TAVR failure</article-title>. <source>JACC Cardiovasc Interv</source>. (<year>2021</year>) <volume>14</volume>(<issue>18</issue>):<fpage>1978</fpage>&#x2013;<lpage>91</lpage>. <pub-id pub-id-type="doi">10.1016/j.jcin.2021.07.015</pub-id><pub-id pub-id-type="pmid">34556271</pub-id></citation></ref>
<ref id="B13"><label>13.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Thiene</surname><given-names>G</given-names></name><name><surname>Bortolotti</surname><given-names>U</given-names></name><name><surname>Valente</surname><given-names>M</given-names></name><name><surname>Milano</surname><given-names>A</given-names></name><name><surname>Calabrese</surname><given-names>F</given-names></name><name><surname>Talenti</surname><given-names>E</given-names></name><etal/></person-group> <article-title>Mode of failure of the hancock pericardial valve xenograft</article-title>. <source>Am J Cardiol</source>. (<year>1989</year>) <volume>63</volume>:<fpage>129</fpage>&#x2013;<lpage>33</lpage>. <pub-id pub-id-type="doi">10.1016/0002-9149(89)91099-0</pub-id><pub-id pub-id-type="pmid">2909146</pub-id></citation></ref>
<ref id="B14"><label>14.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Schoen</surname><given-names>FJ</given-names></name><name><surname>Fernandez</surname><given-names>J</given-names></name><name><surname>Gonzalez-Lavin</surname><given-names>L</given-names></name><name><surname>Cernaianu</surname><given-names>A</given-names></name></person-group>. <article-title>Causes of failure and pathologic findings in surgically removed Ionescu-Shiley standard bovine pericardial heart valve bioprostheses: emphasis on progressive structural deterioration</article-title>. <source>Circulation</source>. (<year>1987</year>) <volume>76</volume>:<fpage>618</fpage>&#x2013;<lpage>27</lpage>. <pub-id pub-id-type="doi">10.1161/01.CIR.76.3.618</pub-id><pub-id pub-id-type="pmid">3621522</pub-id></citation></ref>
<ref id="B15"><label>15.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Luk</surname><given-names>A</given-names></name><name><surname>Cusimano</surname><given-names>RJ</given-names></name><name><surname>Butany</surname><given-names>J</given-names></name></person-group>. <article-title>Pathologic evaluation of 28 mitroflow pericardial valves: a 12-year experience</article-title>. <source>Ann Thorac Surg</source>. (<year>2015</year>) <volume>99</volume>:<fpage>48</fpage>&#x2013;<lpage>54</lpage>. <pub-id pub-id-type="doi">10.1016/j.athoracsur.2014.07.031</pub-id><pub-id pub-id-type="pmid">25442994</pub-id></citation></ref>
<ref id="B16"><label>16.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Schaeffer</surname><given-names>T</given-names></name><name><surname>Berdajs</surname><given-names>D</given-names></name><name><surname>Reuthebuch</surname><given-names>O</given-names></name></person-group>. <article-title>Early surgical aortic bioprosthesis failure caused by cusp tear: a word of caution</article-title>. <source>Clin Case Rep</source>. (<year>2021</year>) <volume>9</volume>:<fpage>286</fpage>&#x2013;<lpage>90</lpage>. <pub-id pub-id-type="doi">10.1002/ccr3.3516</pub-id><pub-id pub-id-type="pmid">33489175</pub-id></citation></ref>
<ref id="B17"><label>17.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tarantini</surname><given-names>G</given-names></name><name><surname>Sathananthan</surname><given-names>J</given-names></name><name><surname>Fabris</surname><given-names>T</given-names></name><name><surname>Landes</surname><given-names>U</given-names></name><name><surname>Bapat</surname><given-names>VN</given-names></name><name><surname>Khanet</surname><given-names>JF</given-names></name><etal/></person-group> <article-title>Transcatheter aortic valve replacement in failed transcatheter bioprosthetic valves</article-title>. <source>JACC Cardiovasc Interv</source>. (<year>2022</year>) <volume>15</volume>(<issue>18</issue>):<fpage>1777</fpage>&#x2013;<lpage>93</lpage>. <pub-id pub-id-type="doi">10.1016/j.jcin.2022.07.035</pub-id><pub-id pub-id-type="pmid">36137681</pub-id></citation></ref></ref-list>
</back>
</article>