<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="review-article" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xml:lang="EN">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Cardiovasc. Med.</journal-id>
<journal-title>Frontiers in Cardiovascular Medicine</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Cardiovasc. Med.</abbrev-journal-title>
<issn pub-type="epub">2297-055X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fcvm.2023.1130354</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Cardiovascular Medicine</subject>
<subj-group>
<subject>Systematic Review</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>The safety and efficacy of balloon-expandable versus self-expanding trans-catheter aortic valve replacement in high-risk patients with severe symptomatic aortic stenosis</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes"><name><surname>Senguttuvan</surname><given-names>Nagendra Boopathy</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="corresp" rid="cor1">&#x002A;</xref><uri xlink:href="https://loop.frontiersin.org/people/62230/overview"/></contrib>
<contrib contrib-type="author"><name><surname>Bhatt</surname><given-names>Hemal</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib>
<contrib contrib-type="author"><name><surname>Balakrishnan</surname><given-names>Vinod Kumar</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/2156288/overview" /></contrib>
<contrib contrib-type="author"><name><surname>Krishnamoorthy</surname><given-names>Parasuram</given-names></name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib>
<contrib contrib-type="author"><name><surname>Goel</surname><given-names>Sunny</given-names></name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib>
<contrib contrib-type="author"><name><surname>Reddy</surname><given-names>Pothireddy M. K.</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib>
<contrib contrib-type="author"><name><surname>Subramanian</surname><given-names>Vinodhini</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref></contrib>
<contrib contrib-type="author"><name><surname>Claessen</surname><given-names>Bimmer E.</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
<xref ref-type="aff" rid="aff4"><sup>4</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/2047063/overview" /></contrib>
<contrib contrib-type="author"><name><surname>Kumar</surname><given-names>Ashish</given-names></name>
<xref ref-type="aff" rid="aff5"><sup>5</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/1821638/overview" /></contrib>
<contrib contrib-type="author"><name><surname>Majmundar</surname><given-names>Monil</given-names></name>
<xref ref-type="aff" rid="aff6"><sup>6</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/2140246/overview" /></contrib>
<contrib contrib-type="author"><name><surname>Ro</surname><given-names>Richard</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/1001577/overview" /></contrib>
<contrib contrib-type="author"><name><surname>Lerakis</surname><given-names>Stamatios</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/1814644/overview" /></contrib>
<contrib contrib-type="author"><name><surname>Jayaraj</surname><given-names>Ramamoorthi</given-names></name>
<xref ref-type="aff" rid="aff7"><sup>7</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/583870/overview" /></contrib>
<contrib contrib-type="author"><name><surname>Kalra</surname><given-names>Ankur</given-names></name>
<xref ref-type="aff" rid="aff5"><sup>5</sup></xref>
<xref ref-type="aff" rid="aff8"><sup>8</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/991402/overview" /></contrib>
<contrib contrib-type="author"><name><surname>Flather</surname><given-names>Marcus</given-names></name>
<xref ref-type="aff" rid="aff9"><sup>9</sup></xref></contrib>
<contrib contrib-type="author"><name><surname>Dangas</surname><given-names>George</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref><uri xlink:href="https://loop.frontiersin.org/people/704662/overview" /></contrib>
</contrib-group>
<aff id="aff1"><label><sup>1</sup></label><addr-line>Department of Cardiology</addr-line>, <institution>Sri Ramachandra Institute of Higher Education and Research</institution>, <addr-line>Chennai</addr-line>, <country>India</country></aff>
<aff id="aff2"><label><sup>2</sup></label><addr-line>Department of Cardiology</addr-line>, <institution>The Zena and Michael A. Wiener Cardiovascular Institute, Icahn School of Medicine at Mount Sinai</institution>, <addr-line>New York, NY</addr-line>, <country>United States</country></aff>
<aff id="aff3"><label><sup>3</sup></label><addr-line>Department of Cardiology</addr-line>, <institution>Hackensack Meridian Health</institution>, <addr-line>New Jersey, NJ</addr-line>, <country>United States</country></aff>
<aff id="aff4"><label><sup>4</sup></label><addr-line>Department of Cardiology</addr-line>, <institution>Amsterdam University Medical Centres</institution>, <addr-line>Amsterdam</addr-line>, <country>the Netherlands</country></aff>
<aff id="aff5"><label><sup>5</sup></label><addr-line>Department of Internal Medicine</addr-line>, <institution>Cleveland Clinic Akron General</institution>, <addr-line>Akron, OH</addr-line>, <country>United States</country></aff>
<aff id="aff6"><label><sup>6</sup></label><addr-line>Department of Internal Medicine</addr-line>, <institution>New York Medical College, Metropolitan Hospital</institution>, <addr-line>New York, NY</addr-line>, <country>United States</country></aff>
<aff id="aff7"><label><sup>7</sup></label><addr-line>Jindal Institute of Behavioral Sciences (JIBS)</addr-line>, <institution>Jindal Global Institution of Eminence Deemed to Be University</institution>, <addr-line>Sonipat</addr-line>, <country>India</country></aff>
<aff id="aff8"><label><sup>8</sup></label><addr-line>Department of Cardiovascular Medicine</addr-line>, <institution>Franciscan Health, Indiana, IN, USA; Co-CEO, Kalra Hospitals</institution>, <addr-line>New Delhi</addr-line>, <country>India</country></aff>
<aff id="aff9"><label><sup>9</sup></label><addr-line>Professor of Cardiology, Norwich Medical School</addr-line>, <institution>University of East Anglia</institution>, <addr-line>Norwich</addr-line>, <country>United Kingdom</country></aff>
<author-notes>
<fn fn-type="edited-by"><p><bold>Edited by:</bold> Mamoo Nakamura, Cedars Sinai Medical Center, United States</p></fn>
<fn fn-type="edited-by"><p><bold>Reviewed by:</bold> Raymond McKay, Hartford HealthCare, United States Masaki Izumo, St. Marianna University School of Medicine, Japan</p></fn>
<corresp id="cor1"><label>&#x002A;</label><bold>Correspondence:</bold> Nagendra Boopathy Senguttuvan <email>nagendraboopathy@sriramachandra.edu.in</email>, <email>drsnboopathy@gmail.com</email></corresp>
<fn fn-type="other" id="fn001"><p>Abbreviations AS, aortic stenosis; TAVR, trans-catheter aortic valve replacement; SAVR, surgical aortic valve replacement; BEV, balloon-expandable valve; SEV, self-expanding valve; FDA, food and drug adminstration; CE, Conformit&#x00E8; Europ&#x00EB;enne.</p></fn>
</author-notes>
<pub-date pub-type="epub"><day>25</day><month>05</month><year>2023</year></pub-date>
<pub-date pub-type="collection"><year>2023</year></pub-date>
<volume>10</volume><elocation-id>1130354</elocation-id>
<history>
<date date-type="received"><day>23</day><month>12</month><year>2022</year></date>
<date date-type="accepted"><day>02</day><month>05</month><year>2023</year></date>
</history>
<permissions>
<copyright-statement>&#x00A9; 2023 Senguttuvan, Bhatt, Balakrishnan, Krishnamoorthy, Goel, Reddy, Subramanian, Claessen, Kumar, Majmundar, Ro, Lerakis, Jayaraj, Kalra, Flather and Dangas.</copyright-statement>
<copyright-year>2023</copyright-year><copyright-holder>Senguttuvan, Bhatt, Balakrishnan, Krishnamoorthy, Goel, Reddy, Subramanian, Claessen, Kumar, Majmundar, Ro, Lerakis, Jayaraj, Kalra, Flather and Dangas</copyright-holder><license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the <ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by/4.0/">Creative Commons Attribution License (CC BY)</ext-link>. The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license>
</permissions>
<abstract><sec><title>Aim</title>
<p>Transfemoral Trans-catheter Aortic Valve Replacement (TF-TAVR) is a safe and effective therapy compared with surgical aortic valve replacement (SAVR) in patients across all risk profiles using balloon-expandable valves (BEV) and self-expanding valves (SEV). Our aim was to compare safety and efficacy of BEV vs. SEV in high-risk patients undergoing TF-TAVR.</p>
</sec><sec><title>Methods and results</title>
<p>We searched PubMed, EMBASE, <ext-link ext-link-type="uri" xlink:href="Clinicaltrials.gov">Clinicaltrials.gov</ext-link>, Scopus, and Web of sciences for studies on patients with severe aortic stenosis undergoing TAVR. Primary outcome was 30-day all-cause mortality. Secondary outcomes defined by Valve Academic Research Consortium 2 (VARC-2) criteria were also examined. Six studies with 2,935 patients (1,439 to BEV and 1,496 to SEV) were included. BEV was associated with lower risk of all-cause mortality (2.2&#x0025; vs. 4.5&#x0025;; RR: 0.51; 95&#x0025; CI: 0.31&#x2013;0.82; <italic>p</italic>&#x2009;&#x003C;&#x2009;0.006) and cardiovascular mortality [(2.5&#x0025; vs. 4.3&#x0025;; RR: 0.54; 95&#x0025; CI: 0.32&#x2013;0.90; <italic>p</italic>&#x2009;&#x003D;&#x2009;0.01) at 30 days compared with SEV. Implantation of more than one valve per procedure (0.78&#x0025; vs. 5.11&#x0025;; RR: 0.15; 95&#x0025; CI: 0.07&#x2013;0.31; <italic>p</italic>&#x2009;&#x003C;&#x2009;0.00001), and moderate/severe AR/PVL (2.5&#x0025; vs. 9.01&#x0025;; RR: 0.3; 95&#x0025; CI: 0.17&#x2013;0.48); <italic>p</italic>&#x2009;&#x003C;&#x2009;0.00001) were also lower in the BEV arm.</p>
</sec><sec><title>Conclusion</title>
<p>BEV TAVR is associated with reduced all-cause mortality (High level of GRADE evidence), cardiovascular mortality (very low level) at 30 days compared with SEV TAVR in high surgical risk patients. Data are necessary to determine if the difference in outcomes persists in longer-term and if the same effects are seen in lower-risk patients.
</p>
</sec><sec><title>Systematic Review Registration</title>
<p>identifier, CRD42020181190.</p>
</sec>
</abstract>
<kwd-group>
<kwd>aortic stenosis</kwd>
<kwd>valve</kwd>
<kwd>balloon expandable</kwd>
<kwd>trans catheter aortic valve replacement</kwd>
<kwd>self-expanding</kwd>
</kwd-group><counts>
<fig-count count="6"/>
<table-count count="1"/><equation-count count="0"/><ref-count count="26"/><page-count count="0"/><word-count count="0"/></counts><custom-meta-wrap><custom-meta><meta-name>section-at-acceptance</meta-name><meta-value>Heart Valve Disease</meta-value></custom-meta></custom-meta-wrap>
</article-meta>
</front>
<body><sec id="s1" sec-type="intro"><label>1.</label><title>Introduction</title>
<p>Trans-catheter aortic valve replacement (TAVR) is an established therapy for patients with symptomatic severe aortic stenosis (AS) across all surgical risk profiles (<xref ref-type="bibr" rid="B1">1</xref>). Three different platforms of trans-catheter heart valves are currently available: balloon-expandable valve (BEV), self-expanding valve (SEV) and mechanically expandable valve (MEV) (<xref ref-type="bibr" rid="B2">2</xref>). The United States Food and Drug Administration (FDA) has approved BEV devices including Sapien, Sapien-XT, Sapien-3 and Sapien-3 Ultra (Edwards Lifesciences, Irvine, CA, USA), SEV devices including CoreValve, Evolut R, Evolut Pro and Evolut-Pro&#x002B; (Medtronic, Minneapolis, MN, USA) in all AS patients, and LOTUS Edge&#x2122; (Boston Scientific, Boston, MA, USA) in high or greater risk patients (<xref ref-type="bibr" rid="B3">3</xref>&#x2013;<xref ref-type="bibr" rid="B5">5</xref>). Other commonly used self-expanding devices outside the United States include Conformit&#x00E8; Europ&#x00EB;enne (CE) marked devices like Acurate-Neo (Boston Scientific, Boston, MA, USA), Portico (Abbott Structural Heart, Santa Clara, CA, USA), Jena Valve (Jena Valve Technologies, Irvine, CA, USA), and Allegra (New Valve Technologies, Germany), and China FDA approved Venus-A (Venus Meditech, China) (<xref ref-type="bibr" rid="B2">2</xref>). Recently, Lotus Edge has been retrieved from the market. TAVR has overcome SAVR in the United States. But studies comparing the outcomes of different transcatheter valve systems are limited. It is well known that BEV is associated with few pacemaker requirements than SEV. But data regarding other hard-end points are scare. We therefore performed a systematic review and meta-analysis of randomized studies to study the safety and efficacy of TAVR using BEV vs. SEV devices in high risk patients.</p>
</sec>
<sec id="s2" sec-type="methods"><label>2.</label><title>Methods</title>
<sec id="s2a"><label>2.1.</label><title>Study eligibility</title>
<p>Studies were included, if they fulfilled the following criteria.
<list list-type="simple">
<list-item><label>a)</label>
<p>Randomized controlled trials (RCTs) in patients with severe native AS undergoing TAVR.</p></list-item>
<list-item><label>b)</label>
<p>RCTs or <italic>post hoc</italic> analysis of RCTs comparing valve platforms into BEV vs. SEV or an RCT with pre-specified analysis by valve platforms. If a trial included MEV platform in either study arm (SEV or BEV), then it had to be &#x003C;5&#x0025; for inclusion in the current study.</p></list-item>
<list-item><label>c)</label>
<p>Study should report all-cause mortality at 30 days as either primary or secondary outcome.</p></list-item>
</list></p>
</sec>
<sec id="s2b"><label>2.2.</label><title>Search strategy</title>
<p>We searched PubMed, EMBASE, <ext-link ext-link-type="uri" xlink:href="Clinicaltrials.gov">Clinicaltrials.gov</ext-link>, Scopus, and Web of science for all studies on patients with severe aortic stenosis undergoing TAVR (since inception to April 17th 2020) without any language restriction. We used multiple posting suffix (.mp) to improve sensitivity of our search. In addition, we looked for cross-references in the screened studies, review articles, and meta-analyses to identify other potential studies to be included. Our detailed search strategy is provided in the <xref ref-type="sec" rid="s8">Supplementary Material</xref>. The study protocol is registered with PROSPERO, International prospective register of systematic reviews (CRD42020181190).</p>
</sec>
<sec id="s2c"><label>2.3.</label><title>Eligibility assessment, data extraction and validity assessment</title>
<p>The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement was followed during the development of this systematic review and meta-analysis (<xref ref-type="bibr" rid="B6">6</xref>). After eliminating duplicates, screening of manuscripts was done based on title and abstracts to remove irrelevant articles by two independent authors. Full text assessment of relevant, identified articles were scrutinized again by the above authors. Risk of bias assessment was done using Cochrane risk-of-bias tool for randomized trials version 2 (RoB 2) (<xref ref-type="bibr" rid="B7">7</xref>). Assessment of risk of bias, inconsistency, indirectness, imprecision, publication bias and effect size were assessed to calculate &#x201C;certainty of evidence&#x201D; using the GRADE (Grading of Recommendations, Assessment, Development and Evaluations) approach (<xref ref-type="bibr" rid="B8">8</xref>). Furthermore, the GRADEpro guideline development tool was used to create a &#x201C;Summary of findings&#x201D; table and a GRADE &#x201C;Evidence profile&#x201D;. Screening, full-text assessment, data extraction and validity assessment were independently performed by two authors (NBS and HB). Discrepancy was resolved by the third author (BC). We extracted baseline characteristics of patients, procedural details and clinical outcomes from included studies.</p>
</sec>
<sec id="s2d"><label>2.4.</label><title>Outcomes</title>
<p>The primary outcome of our study was all-cause mortality at 30 days. Several endpoints on early safety, clinical efficacy and device success as defined by Valve Academic Research Consortium-2 (VARC-2) criteria were examined as secondary outcomes (<xref ref-type="bibr" rid="B9">9</xref>), including cardiovascular (CV) mortality, all stroke (disabling and non-disabling), life-threatening bleeding, major vascular complications, major bleeding, acute kidney injury (AKI) Stage 2 or 3 (including renal replacement therapy), myocardial infarction (MI), coronary artery obstruction requiring intervention, valve-related dysfunction requiring repeat procedure, moderate to severe aortic regurgitation (AR)/para-valvular leak (PVL), atrial fibrillation, rehospitalizations for valve-related symptoms or worsening congestive heart failure, permanent pacemaker implantation, prosthetic valve endocarditis, valve thrombosis, NYHA class III or IV, early valve-related dysfunction, implantation of more than one valve per procedure, valve malposition, and annular rupture. Whenever outcomes reported were too few in numbers (&#x003C;5 events) or reported by a single study only, they were not included in the final analysis.</p>
</sec>
<sec id="s2e"><label>2.5.</label><title>Statistical analysis</title>
<p>Data extracted from the studies were imported into Review Manager Version 5.3 (The Nordic Cochrane Center, The Cochrane Collaboration Copenhagen, Denmark) for analysis. Pairwise meta-analysis was performed for overall analysis. We used DerSimonian and Laird random effects model for our analysis to calculate pooled risk ratio (RR) and 95&#x0025; confidence interval (CI) for all outcomes. We calculated between-study heterogeneity by using the Higgins I2 statistic. We defined low and high heterogeneity as <italic>I</italic><sup>2</sup>&#x2009;&#x003C;&#x2009;25&#x0025; and &#x003E;75&#x0025; respectively. Publication bias was assessed visually by asymmetry in funnel plots. We performed sensitivity analyses utilizing various factors whenever statistically significant heterogeneity was found. This included an analysis after excluding studies one-by one that were considered an outlier based on methodological or interventional heterogeneity. A leave-one-out sensitivity analysis to remove the effect of one study at a time on our results was also performed. All tests were 2-tailed with a <italic>p</italic> value of &#x003C;0.05 considered significant.</p>
</sec>
</sec>
<sec id="s3" sec-type="results"><label>3.</label><title>Results</title>
<p>We identified 2,207 studies through our databases search (<xref ref-type="fig" rid="F1">Figure&#x00A0;1</xref> and <xref ref-type="sec" rid="s8">Supplementary Table S1</xref>). After removing 807 duplicate results, we selected 1,400 articles for title and abstract screening. We excluded 1,378 publications which were irrelevant. Twenty-two articles were studied for eligibility. Out of 22 studies, 15 were excluded and 6 studies were included for the final analysis. The reasons for exclusion of 16 studies are illustrated in <xref ref-type="fig" rid="F1">Figure&#x00A0;1</xref>.</p>
<fig id="F1" position="float"><label>Figure 1</label>
<caption><p>The preferred reporting items for systematic reviews and meta-analyses (PRISMA) Chart. Electronic search from databases and study selection.</p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fcvm-10-1130354-g001.tif"/>
</fig>
<sec id="s3a"><label>3.1.</label><title>Characteristics of included studies</title>
<p>Six studies were included for final qualitative synthesis, of which four were RCTs (<xref ref-type="bibr" rid="B10">10</xref>&#x2013;<xref ref-type="bibr" rid="B13">13</xref>), two were <italic>post hoc</italic> analysis of RCTs (<xref ref-type="bibr" rid="B14">14</xref>, <xref ref-type="bibr" rid="B15">15</xref>) and one was a pre-specified device or valve type analysis of an RCT investigating the different peri-procedural antithrombotic strategies in patients undergoing TAVR (<xref ref-type="bibr" rid="B15">15</xref>) (<xref ref-type="table" rid="T1">Table&#x00A0;1</xref>). The <italic>post-hoc</italic> study belonged to the Portico-IDE (investigational device exemption) randomized trial, presented at international conferences (<xref ref-type="bibr" rid="B14">14</xref>, <xref ref-type="bibr" rid="B15">15</xref>) but was not yet published in a peer-reviewed at the time of the databases search. Risk of-bias as assessed by RoB-2, showed low risk for 4 studies, some concern for 1 study and high risk for one study (<xref ref-type="sec" rid="s8">Supplementary Table S2</xref>). BEV (Old generation-Sapien-XT and new generation- Sapien-3) was studied against four different types of SEVs (old generation SEV CoreValve and new generation SEVs that included Evolut R, Evolut PRO, Acurate neo, and Portico) and included a total of 3,141 patients (<xref ref-type="fig" rid="F2">Figure&#x00A0;2</xref>). Out of 2,935 patients, 1,439 patients (49.0&#x0025;) received BEV and 1,496 patients (51&#x0025;) received SEV. The mean age of the patient population was 81.9 years and 53.3&#x0025; were female. Baseline characteristics of included studies are summarized in the <xref ref-type="sec" rid="s8">Supplementary Table S3</xref>.</p>
<table-wrap id="T1" position="float"><label>Table 1</label>
<caption><p>Characteristics of trials included in the metanalysis<xref ref-type="table-fn" rid="table-fn1"><sup>a</sup></xref>.</p></caption>
<table frame="hsides" rules="groups">
<colgroup>
<col align="left"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
<col align="center"/>
</colgroup>
<thead>
<tr>
<th valign="top" align="left">Characteristics</th>
<th valign="top" align="center">Study 1</th>
<th valign="top" align="center">Study 2</th>
<th valign="top" align="center">Study 3</th>
<th valign="top" align="center">Study 4</th>
<th valign="top" align="center">Study 5</th>
<th valign="top" align="center">Study 6</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">Study (year)</td>
<td valign="top" align="left">Abdel-Wahab 2014</td>
<td valign="top" align="left">Kooistra 2020</td>
<td valign="top" align="left">Lanz 2019</td>
<td valign="top" align="left">Linke 2017</td>
<td valign="top" align="left">Makkar 2020</td>
<td valign="top" align="left">Thiele 2020</td>
</tr>
<tr>
<td valign="top" align="left">Study design</td>
<td valign="top" align="left">RCT parallel group</td>
<td valign="top" align="left">RCT parallel group</td>
<td valign="top" align="left">RCT parallel group</td>
<td valign="top" align="left">RCT with prespecified analysis</td>
<td valign="top" align="left">RCT with <italic>post-hoc</italic> analysis</td>
<td valign="top" align="left">RCT parallel group</td>
</tr>
<tr>
<td valign="top" align="left">Study period</td>
<td valign="top" align="left">March 2012 and December 2013</td>
<td valign="top" align="left">January 2014 and May 2016</td>
<td valign="top" align="left">February 8, 2017, and February 2, 2019,</td>
<td valign="top" align="left">October 2012 and May 2015</td>
<td valign="top" align="left">May 2014 to October 2017</td>
<td valign="top" align="left">April 2016 to April 2018</td>
</tr>
<tr>
<td valign="top" align="left"><italic>N</italic></td>
<td valign="top" align="left">241</td>
<td valign="top" align="left">56</td>
<td valign="top" align="left">731</td>
<td valign="top" align="left">782</td>
<td valign="top" align="left">692</td>
<td valign="top" align="left">438</td>
</tr>
<tr>
<td valign="top" align="left">Clinical risk</td>
<td valign="top" align="left">High risk</td>
<td valign="top" align="left">High or inoperable</td>
<td valign="top" align="left">Increased or inoperable</td>
<td valign="top" align="left">High</td>
<td valign="top" align="left">High or extreme</td>
<td valign="top" align="left">High</td>
</tr>
<tr>
<td valign="top" align="left">TAVR valve type</td>
<td valign="top" align="left">BEV (Sapien XT) vs. SEV (Corevalve)</td>
<td valign="top" align="left">BEV (Sapien 3) vs. SEV (Corevalve)</td>
<td valign="top" align="left">BEV (Sapien 3) vs. Acurate neo (SEV)</td>
<td valign="top" align="left">BEV (Sapien XT, Sapien 3) vs. SEV (Corevalve (83&#x0025;), Evolut R (17&#x0025;), Other non BEV was used in 5 patients)</td>
<td valign="top" align="left">BEV (Sapien 3) vs. SEV (Evolut R/Pro/Portico)</td>
<td valign="top" align="left">BEV (Sapien 3) vs. SEV (Evolut R)</td>
</tr>
<tr>
<td valign="top" align="left">Primary endpoint</td>
<td valign="top" align="left">Device success</td>
<td valign="top" align="left">Severity of post-procedural AR, quantitatively assessed by MRI</td>
<td valign="top" align="left">The primary composite safety and efficacy endpoint the procedure<xref ref-type="table-fn" rid="table-fn2"><sup>b</sup></xref></td>
<td valign="top" align="left">Co-primary outcome was 30-day net adverse cardiac events, NACE, composite of major adverse cardiovascular events, MACE [all-cause mortality, myocardial infarction (MI), or stroke] or major bleeding.</td>
<td valign="top" align="left">Hemodynamics, paravalvular aortic regurgitation, patient prosthesis mismatch (PPM) and clinical outcomes</td>
<td valign="top" align="left">The primary efficacy composite endpoint<xref ref-type="table-fn" rid="table-fn3"><sup>c</sup></xref></td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="table-fn1"><label><sup>a</sup></label>
<p>All included studies have reported all-cause mortality at 30 days as per our inclusion criteria.</p></fn>
<fn id="table-fn2"><label><sup>b</sup></label>
<p>Comprised all-cause death, any stroke, life-threatening or disabling bleeding, major vascular complications, coronary artery obstruction requiring intervention, acute kidney injury (stage 2 or 3), rehospitalisation for valve-related symptoms or congestive heart failure, valve-related dysfunction requiring repeat procedure, moderate or severe prosthetic valve regurgitation, or prosthetic valve stenosis within 30 days.</p></fn>
<fn id="table-fn3"><label><sup>c</sup></label>
<p>Composite endpoint of all-cause mortality, stroke, moderate/severe prosthetic valve regurgitation, and permanent pacemaker implantation at 30 days was powered for equivalence.</p></fn>
</table-wrap-foot>
</table-wrap>
<fig id="F2" position="float"><label>Figure 2</label>
<caption><p>Comparison of balloon expandable platform vs. self-expanding platforms in high risk patients undergoing TAVR, BEV is associated with reduced risk of all-cause mortality at 30 days compared with SEV (<bold>A</bold>). The sub-group difference was not significant when the studies were stratified for the type of study (<bold>B</bold>). BEV, balloon expandable valve; SEV, self-expanding valve; TAVR, transcatheter aortic valve replacement; M-H, Mantel-Haenszel; CI, confidence interval.</p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fcvm-10-1130354-g002.tif"/>
</fig>
</sec>
<sec id="s3b"><label>3.2.</label><title>Clinical outcomes in the patient population</title>
<p>Data regarding all-cause mortality was available from all six studies. Out of 1,439 patients who received BEV, 32 patients (2.2&#x0025;) died at 30-day follow-up. In the SEV group, 67 patients (4.5&#x0025;) died out of 1,496 patients. BEV was associated with significantly lower risk of death at 30 days compared with SEV [(2.2&#x0025; vs. 4.5&#x0025;; RR: 0.51; 95&#x0025; CI: 0.31&#x2013;0.82; <italic>p</italic>&#x2009;&#x003C;&#x2009;0.006, <italic>I</italic><sup>2</sup>&#x2009;&#x003D;&#x2009;6&#x0025;); High level of GRADE Evidence); (Central Illustration, <xref ref-type="fig" rid="F2">Figure&#x00A0;2</xref>)]. Sub-group analysis was performed showed no effect of new generation SEV (Evolut-R, Acurate-Neo and Portico) vs. old generation SEV (CoreValve) on the result (<xref ref-type="sec" rid="s8">Supplementary Figure S1</xref>). A sensitivity analysis using Mantel-Haenszel methods using a fixed effect model showed similar result at 30 days (<italic>p</italic>&#x2009;&#x003C;&#x2009;0.0001) (<xref ref-type="sec" rid="s8">Supplementary Figure S2</xref>). Further sensitivity analyses were performed by leave-one out statistical analyses showed similar results (<xref ref-type="sec" rid="s8">Supplementary Figure S3</xref>). Additional analyses based on the role of study type (RCTs comparing BEV vs. SEV head to head with <italic>post-hoc</italic> and pre-specified analyses of RCTs), and the role of recapturable valves revealed no significant subgroup effects (<xref ref-type="fig" rid="F3">Figure&#x00A0;3</xref> and <xref ref-type="sec" rid="s8">Supplementary Figure S4</xref>, respectively). There was no publication bias as assessed by funnel plot (<xref ref-type="sec" rid="s8">Supplementary Figure S5</xref>).</p>
<fig id="F3" position="float"><label>Figure 3</label>
<caption><p>Comparison of balloon expandable platform with old generation self-expanding platforms for to assess the role of study type (RCTs comparing BEV vs. SEV head to head with <italic>post-hoc</italic> and pre-specified analyses of RCTs) showing no between-the-group difference on the result. BEV, balloon expandable valve; SEV, self-expanding valve; TAVR, trans-catheter aortic valve replacement; M-H, Mantel-Haenszel; CI, confidence interval.</p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fcvm-10-1130354-g003.tif"/>
</fig>
<p>CV mortality at 30 days was available in 5 studies. BEV was associated with lower 30-day CV mortality compared with SEV [(2.5&#x0025; vs. 4.3&#x0025;; RR: 0.54; 95&#x0025; CI: 0.32&#x2013;0.90; <italic>p</italic>&#x2009;&#x003D;&#x2009;0.02; <italic>I</italic><sup>2</sup>&#x2009;&#x003D;&#x2009;0&#x0025;; Very low level of GRADE Evidence) (<xref ref-type="fig" rid="F4">Figure&#x00A0;4A</xref>)]. Implantation of more than one valve per procedure (0.8&#x0025; vs. 5.1&#x0025;; RR: 0.15; 95&#x0025; CI: 0.07&#x2013;0.31); <italic>p</italic>&#x2009;&#x003C;&#x2009;0.00001; <italic>I</italic><sup>2</sup>&#x2009;&#x003D;&#x2009;0&#x0025;; moderate level of GRADE Evidence), and moderate/severe AR/PVL (2.5&#x0025; vs. 9.0&#x0025;; RR: 0.29; 95&#x0025; CI: 0.17&#x2013;0.48); <italic>p</italic>&#x2009;&#x003C;&#x2009;0.00001; <italic>I</italic><sup>2</sup>&#x2009;&#x003D;&#x2009;0&#x0025;; high level of GRADE Evidence) were also lower in the BEV arm (<xref ref-type="fig" rid="F5">Figures&#x00A0;5A,B</xref>). A trend of reduced usage of pacemaker was observed with BEV as compared with SEV [(13.8&#x0025; vs. 18.3&#x0025;; RR: 0.73; 95&#x0025; CI: 0.52&#x2013;1.02; <italic>p</italic>&#x2009;&#x003D;&#x2009;0.06; <italic>I</italic><sup>2</sup>&#x2009;&#x003D;&#x2009;42&#x0025;; very low level of GRADE Evidence) <xref ref-type="fig" rid="F5">Figure&#x00A0;5C</xref>].</p>
<fig id="F4" position="float"><label>Figure 4</label>
<caption><p>Comparison of balloon expandable platform vs. self-expanding platforms for cardiovascular mortality (<bold>A</bold>), stroke (<bold>B</bold>) and early safety (<bold>C</bold>) at 30 days in high risk patients undergoing TAVR. BEV, balloon expandable valve; SEV, self-expanding valve; TAVR, transcatheter aortic valve replacement; M-H, Mantel-Haenszel; CI, confidence interval.</p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fcvm-10-1130354-g004.tif"/>
</fig>
<fig id="F5" position="float"><label>Figure 5</label>
<caption><p>Comparison of balloon expandable platform vs. self-expanding platforms for implantation of &#x003E;1 valve per procedure (<bold>A</bold>), moderate to severe AR/PVL (<bold>B</bold>), new PPM requirement (<bold>C</bold>), and device success as defined by VARC (<bold>D</bold>) at 30 days in high risk patients undergoing TAVR. BEV, balloon expandable valve; SEV, self-expanding valve; AR, aortic regurgitation; PVL, para valvular leak; PPM, permanent pacemaker; TAVR, transcatheter aortic valve replacement; VARC, valve academic research consortium; M-H, Mantel-Haenszel; CI, confidence interval.</p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fcvm-10-1130354-g005.tif"/>
</fig>
<p>All stroke (disabling and non-disabling) data were available in 6 studies. No significant difference in all stroke at 30 days was observed (<xref ref-type="fig" rid="F4">Figure&#x00A0;4B</xref>). Similarly, no significant difference was noted between the 2 groups for early safety outcome at 30 days (<xref ref-type="fig" rid="F4">Figure&#x00A0;4C</xref>), device success (<xref ref-type="fig" rid="F5">Figure&#x00A0;5D</xref>), life-threatening bleeding, major vascular complications, AKI and atrial fibrillation (<xref ref-type="fig" rid="F6">Figures&#x00A0;6A&#x2013;D</xref>). In addition, no significant difference was found between the study arms for MI, major bleeding, rehospitalizations for valve-related symptoms or worsening congestive heart failure, valve related dysfunction requiring repeat procedure, valve malposition, and clinical efficacy (<xref ref-type="sec" rid="s8">Supplementary Figures S6&#x2013;S11</xref>). Sensitivity analysis using fixed effect model showed no difference in all the above parameters except AKI which was significantly lower in patients receiving BEV, with moderate heterogeneity (RR: 0.64; 95&#x0025; CI: 0.40&#x2013;1.01); <italic>p</italic>&#x2009;&#x003D;&#x2009;0.06; <italic>I</italic><sup>2</sup>&#x2009;&#x003D;&#x2009;48&#x0025;) (<xref ref-type="sec" rid="s8">Supplementary Table S4</xref>). Outcomes on cardiac tamponade, annular rupture, NYHA class improvement, NYHA status &#x2265;class 3, and conversion to open heart surgery and valve related dysfunction were not analyzed as their reported numbers were very low.</p>
<fig id="F6" position="float"><label>Figure 6</label>
<caption><p>Comparison of balloon expandable platform vs. self-expanding platforms for life-threatening bleeding (<bold>A</bold>), major vascular complications (<bold>B</bold>), acute kidney injury (<bold>C</bold>), and atrial fibrillation (<bold>D</bold>) at 30 days in high risk patients undergoing TAVR. BEV, balloon expandable valve; SEV, self-expanding valve; TAVR, transcatheter aortic valve replacement; M-H, Mantel-Haenszel; CI, confidence interval.</p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="fcvm-10-1130354-g006.tif"/>
</fig>
</sec>
<sec id="s3c"><label>3.3.</label><title>Risk of bias assessment and quality of evidence</title>
<p>Four out of six studies had only low risk of bias assessment as assessed by Cochrane risk-of-bias tool for randomized trials version 2 (RoB 2). Two studies had some concern and one study was deemed to have risk of bias. GRADE system-based quality assessment was done for individual outcomes and a &#x201C;Summary of findings&#x201D; and GRADE &#x201C;Evidence profile&#x201D; are discussed in the <xref ref-type="sec" rid="s8">Supplementary Tables S5, S6</xref> respectively.</p>
</sec>
</sec>
<sec id="s4" sec-type="discussion"><label>4.</label><title>Discussion</title>
<p>In this meta-analysis of RCTs evaluating different THV platforms in high risk TAVR patients, BEV was associated with a lower risk of all-cause mortality at 30 days. In addition, BEV was found to be associated with lower CV mortality, reduced need for implantation of more than one valve per procedure, trend of decreased need for permanent pacemaker, and a lower incidence of moderate- severe AR/PVL at 30 days. There was no difference between BEV and SEV in terms of all stroke, MI, life-threatening bleeding, major vascular complications, rehospitalizations for valve-related symptoms or worsening congestive heart failure, valve related dysfunction requiring repeat procedure, valve malposition, AKI, atrial fibrillation, device success, early safety and clinical efficacy at 30 days. To our knowledge, this is the first systematic review and meta-analysis comparing BEV vs. all SEV platforms. The strengths of our systematic review include inclusion of RCTs only (including <italic>post hoc</italic> analysis or pre-specified analysis), detailed assessment of risk of-bias and rating the certainty of evidence utilizing the GRADE approach for all outcomes.</p>
<p>Only few studies have compared the safety and efficacy of BEV vs. SEV. The CENTER collaboration investigators studied 4,096 pairs of patients using propensity score matching from a pool of 12,381 TAVR patients (<xref ref-type="bibr" rid="B17">17</xref>). They observed lower in-hospital mortality in the BEV arm compared with the SEV arm (RR&#x2009;&#x003D;&#x2009;0.8; 95&#x0025; CI: 0.6&#x2013;0.9; <italic>p</italic>&#x2009;&#x003D;&#x2009;0.009); however, no difference was seen in 30 day-mortality [5.3&#x0025; vs. 6.2&#x0025;; relative risk, 0.9 (95&#x0025; CI: 0.7&#x2013;1.0); <italic>p&#x2009;</italic>&#x003D;&#x2009;0.10]. Similarly, reduced incidence of stroke (<italic>p&#x2009;</italic>&#x003D;&#x2009;0.03) and pacemaker requirement (<italic>p</italic>&#x2009;&#x003C;&#x2009;0.001) was noted in BEV. In contrast to our meta-analysis which included only RCTs, CENTER collaboration aggregated data from 9 registries and only one RCT. A recently published Bayesian meta-analysis comparing BEV vs. SEV found no difference in all-cause mortality, CV mortality, stroke, PVL, vascular complications but showed less pacemaker implantation with BEV (<xref ref-type="bibr" rid="B18">18</xref>). In contrast to our study, Osman et al. included 8 RCTs of all risk categories, out of which only one was a RCT comparing BEV with SEV in a head-to-head fashion. Four more studies have been published or presented comparing BEV with SEV using three different platforms after the above meta-analysis. Hence, an appropriately conducted pair-wise meta-analysis is warranted to compare the safety and efficacy of BEV vs. SEV.</p>
<p>Two RCTs comparing BEV vs. SEV were recently published. In SCOPE-1, 739 high risk patients were randomized to receive Acurate-Neo vs. Sapien 3. SEV failed to meet its non-inferiority for primary safety and clinical efficacy composite endpoint at 30 days (<xref ref-type="bibr" rid="B12">12</xref>). SOLVE-TAVI compared SEV (Evolut R) with BEV (Sapien-3) (<xref ref-type="bibr" rid="B13">13</xref>) among 447 high risk patients with aortic stenosis undergoing TF TAVR. No difference in all-cause mortality was observed at 30 days (<italic>p</italic> valve for equivalence &#x003C;0.0001). A recently presented <italic>post-hoc</italic> analysis of PORTICO-IDE RCT (<xref ref-type="bibr" rid="B14">14</xref>, <xref ref-type="bibr" rid="B15">15</xref>) comparing Portico SEV vs. commercially available Sapien-3 and Evolut R showed lower mortality in BEV at 30 days (Log-rank <italic>p</italic>&#x2009;&#x003D;&#x2009;0.005). The fourth RCT compared SEV with Lotus (MEV) (<xref ref-type="bibr" rid="B19">19</xref>), which is not within the scope of this meta-analysis.</p>
<p>Our study findings were also similar to those observed in two large registry analysis comparing BEV vs. SEV (<xref ref-type="bibr" rid="B20">20</xref>, <xref ref-type="bibr" rid="B21">21</xref>). In the prospective FRANCE-TAVI registry, 3,910 matched pairs were studied from a pool of 12,141 patients. In-hospital mortality was higher in patients with SEV as compared with BEV (matched RR: 1.33; 95&#x0025; CI: 1.06&#x2013;1.16); <italic>p</italic>&#x2009;&#x003D;&#x2009;0.01). SEV was also associated with increase in moderate PVL, implantation of &#x003E;1 device per procedure and permanent pacemaker implantation, although the predominant SEV used was the first-generation CoreValve. In another propensity score matched nationwide analysis from France, 10,459 patients who had received BEV (Sapien-3) or SEV (Evolut-R) were studied. Patients who had BEV had lower 1 year all-cause mortality (RR: 0.88; 95&#x0025; CI: 0.82&#x2013;0.95; <italic>p</italic>&#x2009;&#x003D;&#x2009;0.001), CV death (RR: 0.82; 95&#x0025; CI: 0.73&#x2013;0.92; <italic>p</italic> 0.0004), and rehospitalization for heart failure (RR: 0.84; 95&#x0025; CI: 0.78&#x2013;0.90; <italic>p</italic>&#x2009;&#x003C;&#x2009;0.0001) compared with SEV.</p>
<p>In our meta-analysis, TF-TAVR using BEV is associated with a 51&#x0025; relative risk reduction in all-cause mortality and a 42&#x0025; relative risk reduction in CV mortality compared with SEV arm. Test for sub-group difference was not significant based on the role of recapturable SEV or generation of SEV. The observed survival benefit with BEV could be due to their mode of deployment which is quicker, the utility of a flex-catheter in the BEV, decreased occurrence of moderate to severe AR/PVL, and reduced need for implantation of more than one valve per procedure. The use of flexible FlexNAV catheter in the parallel cohort of Portico-IDE showed similar results as compared with the BEV (<xref ref-type="bibr" rid="B15">15</xref>). Moderate or severe AR/PVL has been consistently shown to be associated with higher short-term and long-term mortality (<xref ref-type="bibr" rid="B22">22</xref>, <xref ref-type="bibr" rid="B23">23</xref>). In our study, BEV was associated with a 29&#x0025; relative risk reduction in moderate to severe AR/PVL. This could explain the lower 30-day mortality observed with BEV in our study. Use of a second valve was more common in SEV. However, its association with mortality could not be assessed due to non-availability of patient-level data. Increased need for permanent pacemaker observed in our study with SEV is consistent with current literature (<xref ref-type="bibr" rid="B24">24</xref>). The long-term implication of increased pacemaker requirement is yet to be studied and has to be considered as a significant factor, given expanded use of TAVR in low risk patients.</p>
<sec id="s4a"><label>4.1.</label><title>Limitations</title>
<p>Our limitations include being a study-level meta-analysis and not a patient-level meta-analysis. Comparison of all forms of SEV together might be a limitation in our study given different design characteristics, but all the studied SEV are made of nitinol. Two of them were recapturable (Portico and Evolut R). Sensitivity analyses investigating the impact of recapturable SEVs showed no significant effect on outcomes (<xref ref-type="sec" rid="s8">Supplementary Figure S5</xref>) (<xref ref-type="bibr" rid="B25">25</xref>). Inclusion of <italic>post-hoc</italic> analyses and RCTs with pre-specified endpoints are possible limitations but sensitivity analysis showed no effect on our primary outcome. We limited our analysis to 30-day outcomes due to absence of data across trials. As the outcomes of intention to treat analyses were not available for the <italic>post hoc</italic> studies, we collected data from the utilized modified-as-treated analyses as reported by the authors. Some studies also excluded patients with heavy calcification in the aortic annulus, left ventricular outflow tract (LVOT) or sinotubular junction, limiting the interpretation of these findings to those subgroups. Being a study-level metanalysis, we could not calculate the outcomes based on recently published VARC-3 crtieria (<xref ref-type="bibr" rid="B26">26</xref>).</p>
</sec>
<sec id="s4b"><label>4.2.</label><title>Conclusion</title>
<p>Balloon-expandable TAVR is associated with reduced all-cause mortality (High level of GRADE evidence), CV mortality (Very low level of GRADE evidence) at 30 days compared with self- expanding TAVR in high risk patients undergoing TF-TAVR. Longer-term data are necessary to determine if the difference in outcomes persist and if the same effects are seen in lower risk patients.</p>
</sec>
</sec>
</body>
<back>
<sec id="s5" sec-type="data-availability"><title>Data availability statement</title>
<p>The original contributions presented in the study are included in the article/<xref ref-type="sec" rid="s8"><bold>Supplementary Material</bold></xref>, further inquiries can be directed to the corresponding author.</p>
</sec>
<sec id="s6" sec-type="author-contributions"><title>Author contributions</title>
<p>NS: planning, execution, data extraction, statistics, reporting, writing the first manuscript, review and editing. HB: planning, execution, data extraction, statistics. VB, PK, SG, RR, SL, AKu, MM, RJ, Aka, MF, GD, and VS: review and editing. PR: data extraction, review and editing. BC: planning, execution, review and editing. All authors contributed to the article and approved the submitted version.</p>
</sec>
<ack><title>Acknowledgments</title>
<p>We thank all the fellows who helped us in the making of this manuscript. We thank Savithri in helping us in making the figures.</p>
</ack>
<sec id="s7" sec-type="COI-statement"><title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec id="s9" sec-type="disclaimer"><title>Publisher&#x0027;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<sec id="s8" sec-type="supplementary-material"><title>Supplementary material</title>
<p>The Supplementary Material for this article can be found online at: <ext-link ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/fcvm.2023.1130354/full#supplementary-material">https://www.frontiersin.org/articles/10.3389/fcvm.2023.1130354/full&#x0023;supplementary-material</ext-link></p>
<supplementary-material id="SD1" content-type="local-data">
<media mimetype="application" mime-subtype="vnd.openxmlformats-officedocument.wordprocessingml.document" xlink:href="Datasheet1.docx"/>
</supplementary-material>
</sec>
<ref-list><title>References</title>
<ref id="B1"><label>1.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Siontis</surname><given-names>GCM</given-names></name><name><surname>Overtchouk</surname><given-names>P</given-names></name><name><surname>Cahill</surname><given-names>TJ</given-names></name><etal/></person-group> <article-title>Transcatheter aortic valve implantation vs. surgical aortic valve replacement for treatment of symptomatic severe aortic stenosis: an updated meta-analysis</article-title>. <source>Eur Heart J</source>. (<year>2019</year>) <volume>40</volume>(<issue>38</issue>):<fpage>3143</fpage>&#x2013;<lpage>53</lpage>. <pub-id pub-id-type="doi">10.1093/eurheartj/ehz275</pub-id><pub-id pub-id-type="pmid">31329852</pub-id></citation></ref>
<ref id="B2"><label>2.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bourantas</surname><given-names>CV</given-names></name><name><surname>Modolo</surname><given-names>R</given-names></name><name><surname>Baumbach</surname><given-names>A</given-names></name><etal/></person-group> <article-title>The evolution of device technology in transcatheter aortic valve implantation</article-title>. <source>EuroIntervention</source>. (<year>2019</year>) <volume>14</volume>(<issue>18</issue>):<fpage>e1826</fpage>&#x2013;<lpage>33</lpage>. <pub-id pub-id-type="doi">10.4244/EIJ-D-18-01048</pub-id><pub-id pub-id-type="pmid">30719977</pub-id></citation></ref>
<ref id="B3"><label>3.</label><citation citation-type="other"><collab>Health C for D and R</collab>. <comment>Edwards SAPIEN 3 transcatheter heart valve system and Edwards SAPIEN 3 ultra transcatheter heart valve system - P140031/S085. FDA (2019) (Accessed April 29, 2020)</comment>.</citation></ref>
<ref id="B4"><label>4.</label><citation citation-type="other"><collab>Health C for D and R</collab>. <comment>Medtronic CoreValve system; Medtronic CoreValve Evolut R system; medtronic CoreValve Evolut PRO system - P130021/S033. FDA (2019) (Accessed April 29, 2020)</comment>.</citation></ref>
<ref id="B5"><label>5.</label><citation citation-type="other"><collab>Health C for D and R</collab>. <comment>LOTUS Edge&#x2122; valve system - P180029. FDA (2019) (Accessed April 29, 2020)</comment>.</citation></ref>
<ref id="B6"><label>6.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Moher</surname><given-names>D</given-names></name><name><surname>Liberati</surname><given-names>A</given-names></name><name><surname>Tetzlaff</surname><given-names>J</given-names></name><name><surname>Altman</surname><given-names>DG</given-names></name></person-group>, <collab>PRISMA Group</collab>. <article-title>Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement</article-title>. <source>PLoS Med</source>. (<year>2009</year>) <volume>6</volume>(<issue>7</issue>):<fpage>e1000097</fpage>. <pub-id pub-id-type="doi">10.1371/journal.pmed.1000097</pub-id><pub-id pub-id-type="pmid">19621072</pub-id></citation></ref>
<ref id="B7"><label>7.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sterne</surname><given-names>JAC</given-names></name><name><surname>Savovi&#x0107;</surname><given-names>J</given-names></name><name><surname>Page</surname><given-names>MJ</given-names></name><etal/></person-group> <article-title>Rob 2: a revised tool for assessing risk of bias in randomised trials</article-title>. <source>Br Med J</source>. (<year>2019</year>) <volume>28</volume>(<issue>366</issue>):<fpage>l4898</fpage>. <pub-id pub-id-type="doi">10.1136/bmj.l4898</pub-id>.</citation></ref>
<ref id="B8"><label>8.</label><citation citation-type="other"><comment>GRADE handbook (Accessed April 30, 2020)</comment>.</citation></ref>
<ref id="B9"><label>9.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kappetein</surname><given-names>AP</given-names></name><name><surname>Head</surname><given-names>SJ</given-names></name><name><surname>G&#x00E9;n&#x00E9;reux</surname><given-names>P</given-names></name><etal/></person-group> <article-title>Updated standardized endpoint definitions for transcatheter aortic valve implantation: the valve academic research consortium-2 consensus document (VARC-2)</article-title>. <source>Eur J Cardio-Thorac Surg</source>. (<year>2012</year>) <volume>42</volume>(<issue>5</issue>):<fpage>S45</fpage>&#x2013;<lpage>60</lpage>. <pub-id pub-id-type="doi">10.1093/ejcts/ezs533</pub-id></citation></ref>
<ref id="B10"><label>10.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Abdel-Wahab</surname><given-names>M</given-names></name><name><surname>Mehilli</surname><given-names>J</given-names></name><name><surname>Frerker</surname><given-names>C</given-names></name><etal/></person-group> <article-title>Comparison of balloon-expandable vs self-expandable valves in patients undergoing transcatheter aortic valve replacement: the CHOICE randomized clinical trial</article-title>. <source>J Am Med Assoc</source>. (<year>2014</year>) <volume>311</volume>(<issue>15</issue>):<fpage>1503</fpage>&#x2013;<lpage>14</lpage>. <pub-id pub-id-type="doi">10.1001/jama.2014.3316</pub-id></citation></ref>
<ref id="B11"><label>11.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kooistra</surname><given-names>NHM</given-names></name><name><surname>Abawi</surname><given-names>M</given-names></name><name><surname>Voskuil</surname><given-names>M</given-names></name><etal/></person-group> <article-title>Randomised comparison of a balloon-expandable and self-expandable valve with quantitative assessment of aortic regurgitation using magnetic resonance imaging</article-title>. <source>Neth Heart J</source>. (<year>2020</year>) <volume>28</volume>(<issue>5</issue>):<fpage>253</fpage>&#x2013;<lpage>65</lpage>. <pub-id pub-id-type="doi">10.1007/s12471-020-01414-0</pub-id><pub-id pub-id-type="pmid">32246266</pub-id></citation></ref>
<ref id="B12"><label>12.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lanz</surname><given-names>J</given-names></name><name><surname>Kim</surname><given-names>WK</given-names></name><name><surname>Walther</surname><given-names>T</given-names></name><etal/></person-group> <article-title>Safety and efficacy of a self-expanding versus a balloon-expandable bioprosthesis for transcatheter aortic valve replacement in patients with symptomatic severe aortic stenosis: a randomised non-inferiority trial</article-title>. <source>Lancet</source>. (<year>2019</year>) <volume>394</volume>(<issue>10209</issue>):<fpage>1619</fpage>&#x2013;<lpage>28</lpage>. <pub-id pub-id-type="doi">10.1016/S0140-6736(19)32220-2</pub-id><pub-id pub-id-type="pmid">31570258</pub-id></citation></ref>
<ref id="B13"><label>13.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Thiele</surname><given-names>H</given-names></name><name><surname>Kurz</surname><given-names>T</given-names></name><name><surname>Feistritzer</surname><given-names>H-J</given-names></name><etal/></person-group> <article-title>Comparison of newer b generation self-expandable vs. Balloon-expandable valves in transcatheter aortic valve implantation: the randomized SOLVE-TAVI trial</article-title>. <source>Eur Heart J</source>. (<year>2020</year>). <pub-id pub-id-type="doi">10.1093/eurheartj/ehaa036</pub-id></citation></ref>
<ref id="B14"><label>14.</label><citation citation-type="other"><person-group person-group-type="author"><name><surname>Maisano</surname><given-names>PF</given-names></name></person-group>. <comment>PORTICO: a randomized trial of portico vs. commercially available transcatheter aortic valves in patients with severe aortic stenosis. TCTMD.com. (Accessed April 29, 2020)</comment>.</citation></ref>
<ref id="B15"><label>15.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Makkar</surname><given-names>RR</given-names></name><name><surname>Waksman</surname><given-names>R</given-names></name><name><surname>Groh</surname><given-names>M</given-names></name><etal/></person-group> <article-title>Comparison of valve performance of the intra-annular self-expanding Portico&#x2122; transcatheter aortic valve with contemporary supra-annular self-expanding and intra-annular balloon-expandable valves: insights from the PORTICO IDE trial</article-title>. <source>J Am Coll Cardiol Intv</source>. (<year>2020</year>) <volume>13</volume>(<issue>4&#x00A0;Supplement</issue>):<fpage>S46</fpage>. <pub-id pub-id-type="doi">10.1016/j.jcin.2020.01.148</pub-id></citation></ref>
<ref id="B16"><label>16.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Linke</surname><given-names>A</given-names></name><name><surname>Chandrasekhar</surname><given-names>J</given-names></name><name><surname>Sartori</surname><given-names>S</given-names></name><etal/></person-group> <article-title>Effect of valve design and anticoagulation strategy on 30-day clinical outcomes in transcatheter aortic valve replacement: results from the BRAVO 3 randomized trial</article-title>. <source>Catheter Cardiovasc Interv</source>. (<year>2017</year>) <volume>90</volume>(<issue>6</issue>):<fpage>1016</fpage>&#x2013;<lpage>26</lpage>. <pub-id pub-id-type="doi">10.1002/ccd.27154</pub-id><pub-id pub-id-type="pmid">28498562</pub-id></citation></ref>
<ref id="B17"><label>17.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Vlastra</surname><given-names>W</given-names></name><name><surname>Chandrasekhar</surname><given-names>J</given-names></name><name><surname>Mu&#x00F1;oz-Garcia</surname><given-names>AJ</given-names></name><etal/></person-group> <article-title>Comparison of balloon-expandable vs. self-expandable valves in patients undergoing transfemoral transcatheter aortic valve implantation: from the CENTER-collaboration</article-title>. <source>Eur Heart J</source>. (<year>2019</year>) <volume>40</volume>(<issue>5</issue>):<fpage>456</fpage>&#x2013;<lpage>65</lpage>. <pub-id pub-id-type="doi">10.1093/eurheartj/ehy805</pub-id><pub-id pub-id-type="pmid">30590565</pub-id></citation></ref>
<ref id="B18"><label>18.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Osman</surname><given-names>M</given-names></name><name><surname>Ghaffar</surname><given-names>YA</given-names></name><name><surname>Saleem</surname><given-names>M</given-names></name><etal/></person-group> <article-title>Meta-analysis comparing transcatheter aortic valve implantation with balloon versus self-expandable valves</article-title>. <source>Am J Cardiol</source>. (<year>2019</year>) <volume>124</volume>(<issue>8</issue>):<fpage>1252</fpage>&#x2013;<lpage>6</lpage>. <pub-id pub-id-type="doi">10.1016/j.amjcard.2019.07.028</pub-id><pub-id pub-id-type="pmid">31470973</pub-id></citation></ref>
<ref id="B19"><label>19.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Feldman</surname><given-names>TE</given-names></name><name><surname>Reardon</surname><given-names>MJ</given-names></name><name><surname>Rajagopal</surname><given-names>V</given-names></name><etal/></person-group> <article-title>Effect of mechanically expanded vs self-expanding transcatheter aortic valve replacement on mortality and major adverse clinical events in high-risk patients with aortic stenosis: the REPRISE III randomized clinical trial</article-title>. <source>J Am Med Assoc</source>. (<year>2018</year>) <volume>319</volume>(<issue>1</issue>):<fpage>27</fpage>&#x2013;<lpage>37</lpage>. <pub-id pub-id-type="doi">10.1001/jama.2017.19132</pub-id></citation></ref>
<ref id="B20"><label>20.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Van Belle</surname><given-names>E</given-names></name><name><surname>Vincent</surname><given-names>F</given-names></name><name><surname>Labreuche</surname><given-names>J</given-names></name><etal/></person-group> <article-title>Balloon-expandable versus self-expanding transcatheter aortic valve replacement: a propensity-matched comparison from the FRANCE-TAVI registry</article-title>. <source>Circulation</source>. (<year>2020</year>) <volume>141</volume>(<issue>4</issue>):<fpage>243</fpage>&#x2013;<lpage>59</lpage>. <pub-id pub-id-type="doi">10.1161/CIRCULATIONAHA.119.043785</pub-id><pub-id pub-id-type="pmid">31736356</pub-id></citation></ref>
<ref id="B21"><label>21.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Deharo</surname><given-names>P</given-names></name><name><surname>Bisson</surname><given-names>A</given-names></name><name><surname>Herbert</surname><given-names>J</given-names></name><etal/></person-group> <article-title>Impact of Sapien 3 balloon-expandable versus evolut R self-expandable transcatheter aortic valve implantation in patients with aortic stenosis: data from a nationwide analysis</article-title>. <source>Circulation</source>. (<year>2020</year>) <volume>141</volume>(<issue>4</issue>):<fpage>260</fpage>&#x2013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1161/CIRCULATIONAHA.119.043971</pub-id><pub-id pub-id-type="pmid">31736332</pub-id></citation></ref>
<ref id="B22"><label>22.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Athappan</surname><given-names>G</given-names></name><name><surname>Patvardhan</surname><given-names>E</given-names></name><name><surname>Tuzcu</surname><given-names>EM</given-names></name><etal/></person-group> <article-title>Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature</article-title>. <source>J Am Coll Cardiol</source>. (<year>2013</year>) <volume>61</volume>(<issue>15</issue>):<fpage>1585</fpage>&#x2013;<lpage>95</lpage>. <pub-id pub-id-type="doi">10.1016/j.jacc.2013.01.047</pub-id><pub-id pub-id-type="pmid">23500308</pub-id></citation></ref>
<ref id="B23"><label>23.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kodali</surname><given-names>S</given-names></name><name><surname>Pibarot</surname><given-names>P</given-names></name><name><surname>Douglas</surname><given-names>PS</given-names></name><etal/></person-group> <article-title>Paravalvular regurgitation after transcatheter aortic valve replacement with the Edwards sapien valve in the PARTNER trial: characterizing patients and impact on outcomes</article-title>. <source>Eur Heart J</source>. (<year>2015</year>) <volume>36</volume>(<issue>7</issue>):<fpage>449</fpage>&#x2013;<lpage>56</lpage>. <pub-id pub-id-type="doi">10.1093/eurheartj/ehu384</pub-id><pub-id pub-id-type="pmid">25273886</pub-id></citation></ref>
<ref id="B24"><label>24.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Rod&#x00E9;s-Cabau</surname><given-names>J</given-names></name><name><surname>Ellenbogen</surname><given-names>KA</given-names></name><name><surname>Krahn</surname><given-names>AD</given-names></name><etal/></person-group> <article-title>Management of conduction disturbances associated with transcatheter aortic valve replacement: JACC scientific expert panel</article-title>. <source>J Am Coll Cardiol</source>. (<year>2019</year>) <volume>74</volume>(<issue>8</issue>):<fpage>1086</fpage>&#x2013;<lpage>106</lpage>. <pub-id pub-id-type="doi">10.1016/j.jacc.2019.07.014</pub-id></citation></ref>
<ref id="B25"><label>25.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hellhammer</surname><given-names>K</given-names></name><name><surname>Piayda</surname><given-names>K</given-names></name><name><surname>Afzal</surname><given-names>S</given-names></name><name><surname>Kleinebrecht</surname><given-names>L</given-names></name><etal/></person-group> <article-title>The latest evolution of the medtronic CoreValve system in the era of transcatheter aortic valve replacement: matched comparison of the Evolut PRO and Evolut R</article-title>. <source>J Am Coll Cardiol Intv</source>. (<year>2018</year>) <volume>11</volume>(<issue>22</issue>):<fpage>2314</fpage>&#x2013;<lpage>22</lpage>. <pub-id pub-id-type="doi">10.1016/j.jcin.2018.07.023</pub-id></citation></ref>
<ref id="B26"><label>26.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>G&#x00E9;n&#x00E9;reux</surname><given-names>P</given-names></name><name><surname>Piazza</surname><given-names>N</given-names></name><name><surname>Alu</surname><given-names>CM</given-names></name><etal/></person-group> <article-title>Valve academic research consortium 3: updated endpoint definitions for aortic valve clinical researchVARC-3 WRITING COMMITTEE</article-title>. <source>J Am Coll Cardiol</source>. (<year>2021</year>) <volume>77</volume>(<issue>21</issue>):<fpage>2717</fpage>&#x2013;<lpage>46</lpage>. <pub-id pub-id-type="doi">10.1016/j.jacc.2021.02.038</pub-id></citation></ref></ref-list>
</back>
</article>